User Guide

For use with ProSYS 40, and ProSYS 128

RTTE Declaration Of Conformity

Hereby, RISCO Group declares that this control panel (ProSYS 128,

ProSYS 40), with wired accessories (including cables) and wireless accessories, is in compliance with the essential requirements and other relevant provisions of Directive 1999/5/EC.

For the CE Declaration of Conformity please refer to our website: www.riscogroup.com.

Compliance Statement

Hereby, RISCO Group declares that the ProSYS series of control panels and accessories are suitable for use in systems designed to comply with PD6662:2004 Security Grade 3, Environmental Class II.

(Security Grade 2 when using Wireless accessories).

The ProSYS series of control panels and accessories comply with the relevant parts of the EN50131 series of standards. The ProSYS series of control panels and accessories comply with DD243:2004

Important Notice

This manual is delivered subject to the following conditions and restrictions:

Ê

This manual contains proprietary information belonging to RISCO

Group. Such information is supplied solely for the purpose of assisting explicitly and properly authorized users of the system.

Ê

No part of its contents may be used for any other purpose, disclosed to any person or firm or reproduced by any means, electronic or mechanical, without the express prior written permission of RISCO Group.

Ê

The text and graphics are for the purpose of illustration and reference only. The specifications on which they are based are subject to change without notice.

Ê

Information in this document is subject to change without notice.

Corporate and individual names and data used in examples herein are fictitious unless otherwise noted.

Copyright

©

2009 RISCO Group. All rights reserved.

2

ProSYS User Guide

Table of Contents

SUMMARY OF USER COMMANDS................................................. 6

CHAPTER 1: INTRODUCTION......................................................... 9

Operating the System .............................................................10

The ProSYS Family .................................................................11

CHAPTER 2: YOUR KEYPAD........................................................12

The keypad...............................................................................12

LED Indicators .........................................................................12

Power LED.......................................................................... 13

Set LED............................................................................... 13

Ready LED.......................................................................... 14

Omit LED ............................................................................ 14

Fire LED.............................................................................. 15

Tamper LED........................................................................ 15

Keys ..........................................................................................16

Numerical Keys................................................................... 16

Control Keys ....................................................................... 16

Emergency Keys................................................................. 17

Function Keys (A, B)........................................................... 17

Quick Key Operation........................................................... 18

LCD Status Display .................................................................18

LCD Blank Display ..................................................................18

CHAPTER 3: SETTING AND UNSETTING THE SYSTEM............19

Setting ......................................................................................19

Full Setting .......................................................................... 20

Part Setting ......................................................................... 22

Partition Setting .................................................................. 23

Group Setting...................................................................... 25

Quick Setting....................................................................... 26

Keyswitch Setting ............................................................... 26

ProSYS User Guide

3

Wireless 4-Button Key Fob Setting..................................... 27

Unsetting..................................................................................27

Unsetting the System.......................................................... 27

Unsetting After an Alarm..................................................... 28

Resetting after an Alarm ..................................................... 29

Partition Unsetting .............................................................. 30

Duress Unsetting ................................................................ 31

Disabling a Fire Alarm (Switch Auxiliary)............................ 32

CHAPTER 4: OMITTING A ZONE ..................................................33

CHAPTER 5: ACTIVATING PROGRAMMABLE OUTPUTS .........35

CHAPTER 6: FOLLOW-ME REPORT............................................36

CHAPTER 7: USER CODES ..........................................................38

Defining and Changing User Codes......................................38

Deleting User Codes ...............................................................40

User Authority Levels .............................................................41

Entering User Labels ..............................................................42

Assigning Dual Codes ............................................................44

CHAPTER 8: VIEWING FAULT CONDITIONS ..............................45

CHAPTER 9: DEFINING AND CHANGING SYSTEM TIME AND

DATE ...............................................................................................46

Defining and Changing System Time....................................46

Defining and Changing System Date ....................................46

CHAPTER 10: SCHEDULING WEEKLY PROGRAMS..................47

Automatic Setting/Unsetting..................................................47

Defining a PO Activation Program ........................................49

4

ProSYS User Guide

Defining a User Limitation Program......................................51

CHAPTER 11: PROGRAMMING FUNCTION KEYS .....................53

CHAPTER 12: PROXIMITY KEYPAD ............................................56

Adding a New Proximity Tag..................................................56

Deleting a Proximity Tag by the User Serial Number ..........57

Deleting a Proximity Tag by the User Tag ............................58

Using a Proximity Tag.............................................................59

CHAPTER 13: COMPLETE MENU OF USER FUNCTIONS .........60

APPENDIX A: SYSTEM FAULTS...................................................67

APPENDIX B: SYSTEM SOUNDS .................................................69

APPENDIX C: SCHEDULING TABLES .........................................71

APPENDIX D: TERMS AND DEFINITIONS ...................................72

ProSYS User Guide

5

6

Full Set

Summary of User Commands

Hold the tag close to the keypad's keys

-OR-

Part Setting

Group Setting

Code>

Code>

Code>A/B/

Partition Full

Setting

Hold the tag close to the keypad's keys >

Partition No. >

-OR-

Code>

Code>

> Partition No. >

> Partition No. >

Partition Part

Setting

Partition Group

Setting

System Unset

Code>A/B/ > Partition No. > A/B/C/D

Partition Unset

Duress Unset

Silence an Alarm

Omit Zones

Activate Output

Define Follow-Me

Enable Engineer

Installation

View Fault

Hold the tag close to the keypad's keys

-OR-

Code>

Hold the tag close to the keypad's keys >

Partition No. >

-OR-

Code> > Partition No. >

Duress Code >

Hold the tag close to the keypad's keys

-OR-

Code>

>[1]>[1]>[Code] >[Zone No.]

>

>[2]>[1]>[Code] [PO No.]

>[2]>[7]>[Code]

>[2]>[0]>[3]>[Code]>

>[3]>[1]>[Code] >

>

ProSYS User Guide

View Alarm

Memory

View Zone Status

View Event Memory

Bell/Strobe/Keypad

Test

Zone Testing (Walk

Test)

Local Chime On/Off

Edit User Code

Edit Time

Edit Date

Automatic

Setting/Unsetting

>[3]>[2]>[Code]>

>[3]>[4]>[Code]>

>[4]>[Code]>

>[3]>[5]>[Manager Code]>

>[1]

>[0]

>[4]>[Grand Master Code]>

>[4]>[Code]> >[4]/[3]

>[5]>[Code]> >[1]

>[1]

>[6]>[Grand Master Code]>

>[2]

>[6]>[Grand Master Code]>

>[6]>[Grand Master Code]>

>[5]>[Schedule No]>

ProSYS User Guide

7

8

ProSYS User Guide

Chapter 1: Introduction

Congratulations on your purchase of RISCO Group's ProSYS

Integrated Security System. The ProSYS has been designed to meet

PD6662 Grade 3 requirements and suits a wide range of commercial, institutional and residential security applications.

The ProSYS includes the most advanced communication capabilities for dual or triple-path communication to ARC’s. It consists of a variety of sensors, detectors, and contacts placed throughout the premises by your engineer. ProSYS is designed to recognize abnormal conditions and inform the system of the status of any protected door, window, hallway, room, or area. The Main Panel, which contains the system's electronics and backup battery, functions in the background. For purposes of security, it is recommended that it be installed out of sight.

You can place a household appliance or premises lighting under the control of the ProSYS, where it can be conveniently turned on and off automatically or by user command from any system keypad, or wireless keyfob, described on page 35.

In addition, the ProSYS supports the following optional RISCO Group devices:

Ê

Advanced Communication Module (ACM) that enables the system to operate over the IP network.

Ê

GSM (AGM)/GPRS module which enables the system to communicate over the GSM (AGM)/GPRS network, and also send or receive SMS commands.

Ê

Access Control, which enables integrating access control capabilities into your security system.

Ê

Digital Voice Module which enables you to receive voice messages, operate the system from a remote phone, and listen- in or speak to the premises.

ProSYS User Guide

9

10

Operating the System

The ProSYS can easily be operated locally or remotely depending on the devices connected to the system.

You can issue commands to the system and in turn, the system will communicate information to you via its display, indicators, voice messages, SMS messages, Email messages and by the sounds it makes.

The ProSYS can be operated in the following ways:

Ê

Locally through its keypad(s). Using its keys, you can issue commands to your system. In turn, the system can communicate information to you via its display, indicators and sounds it makes.

Ê

Local operation using wireless key fobs or panic pendants for setting, unsetting send panic alarm or activate outputs.

Ê

Local operation using Keyswitch for setting and unsetting the system.

Ê

If your system includes the Voice module, it can provide audible information about system status, and enable any remote, touch-tone (DTMF) telephone to act as a keypad for the system.

Upon event occurrence, such as alarm activation, the Voice module informs you of a security situation by calling you and playing a pre-recorded Event announcement, as described in the

Voice Module Programming and Operations Manual

Ê

If your system is equipped with RISCO Group's GSM(AGM)/GPRS module it can provide information about the system by SMS and enable to operate the system using SMS commands for setting the system, unsetting the system and more. For detailed information refer to the manual provided with the GSM (AGM)/GPRS module.

Ê

Local or remote operation using RISCO Group’s upload/Download

(UD) software. The UD enables the engineer to program the system, and enables the user to operate the system and to view system status.

The first task to be performed before operating the system is

Defining and Changing User Codes

, as described on page 38.

NOTE:

A certified serviceman should perform all repairs and maintenance including replacement of the device battery.

ProSYS User Guide

The ProSYS Family

This manual applies for both ProSYS 40 ProSYS 128 panels. The following table, lists the number of features in each type of panel.

Feature ProSYS 40 ProSYS 128

Total Zones

User Codes

8 - 40 8 - 128

60 99

Programmable Outputs

Follow-Me Destinations

Maximum Keypads

Partitions

6 - 38 6 - 70

8 16

12 16

4 8

Scheduling Weekly

Programs

16 32

ProSYS User Guide

11

Chapter 2: Your Keypad

As a security system user, you will perform most operations using the keypad. This section discusses the keypad's visual indicators and the use of its keys.

The keypad’s type is

LCD Proximity Keypad.

It has the ability to sense when a proximity key tag is near it thus providing the user with a friendly and easy way to set or unset the security system (Refer to

Chapter 12, Proximity Keypad

, page 56).

Each keypad in the system is assigned to a particular partition, meaning that commands entered in a keypad are implemented only in the partition to which it is assigned. For example, pressing the Quick

on a keypad assigned to partition 1 sets only partition 1.

The keypad

Each keypad in your system reports its status via its 6 LED (lighted) indicators at the left, as described on page 12 or via messages displayed on the LCD. Using its keys, you can enter commands to set and unset the system, omit intrusion zones, report emergencies, and so on, as described in the subsequent chapters of this manual.

NOTE:

For detailed information regarding the Touchscreen keypad, refer to the

ProSYS Touchscreen Keypad Instruction manual that is included with the product.

LED Indicators

The six LED indicators found at the upper left provide typical system indications, as discussed below. Some indicators have additional functions, which are explained later on.

NOTE:

If required, setting the keypad to Hidden LCD mode can hide the system status.

In this mode, the Set, Ready and Omit LEDs do not function, and the LCD displays ENTER CODE: After entering a valid user code, the system displays the Normal Operation mode. One minute after the last operation, the system automatically switches to Hidden LCD mode.

12

ProSYS User Guide

NOTE:

For detailed information regarding the LED indicators of the Touchscreen keypad, refer to the ProSYS Touchscreen Keypad Instruction manual that is included with the product.

Power LED

The

Power

LED indicates system operation.

Condition Description

ON

The system is operating properly from mains (AC) power or while the system is Set.

OFF

The system is inoperative due to lack of power form mains (AC) and battery.

RAPID

FLASH

Indicates that mains power is not present for a predefined time (consult your engineer).

NOTE:

Once the system is in Blank Display mode, the Power LED will light steadily.

NOTE:

Once the system is set, a previously flashing or unlit Power LED will light steadily.

Set LED

The

Set

LED indicates whether or not the keypad’s intrusion detectors are set.

Condition Description

ON

The system is fully or partially set.

OFF

The system is fully unset.

SLOW FLASH

The system is in its Exit Delay time period.

RAPID FLASH

Indicates an alarm condition or after unsetting an alarmed system while the display is in

Alarm

Memory

mode.

To restore the display to

Normal Operation

mode, press .

NOTE:

Your engineer can disable the Set LED indication after a predefined time when the system is set.

ProSYS User Guide

13

Ready LED

The

Ready

LED indicates whether or not the alarm’s intrusion zones are secured and ready to be set.

Condition Description

ON

The system is unset and all the intrusion zones are secure; the system is ready to be set and there are no faults in the system.

OFF

One or more intrusion zones are not secure, and the system is not ready to be set. Before the system can be set, the condition must be rectified.

-OR-

For 3 minutes when power is restored to a completely down powered system (if defined by your engineer).

SLOW FLASH

The System is in

User Function

mode.

QUICK FLASH

There is a system fault.

Omit LED

The

Omit

LED is normally lit when

Part Set

mode is selected.

Condition Description

ON

At least one intrusion zone is omitted, or

Part

Set

mode or

Group Set

mode is selected.

OFF

All zones are operating normally and the system is in

Set

mode.

14

ProSYS User Guide

Fire LED

When lit, the

Fire

LED indicates that the system is experiencing a fire alarm. When flashing, a problem has been detected on the fire circuit, and must be serviced.

Condition Description

ON

A fire alarm or fire emergency is in progress or has recently occurred.

OFF

FLASHING

All fire zones are operating normally.

A problem has been detected on the fire circuit and it must be serviced.

Tamper LED

The

Tamper

LED indicates that a zone, a keypad, or an external module has been tampered with and requires resetting. In some cases, an Engineer code is required to restore the system to

Normal

Operation

mode.

Condition Description

ON

A zone, keypad, or an external module used by the system has been physically disturbed or tampered with. If unset without fixing the problem, only the sound will be silenced.

OFF

NOTE:

The TAMPER LED shall NOT be on during tamper condition when the system is SET.

If programmed by your engineer, resetting the TAMPER LED will require the intervention an engineer.

There is no tamper alarm in the system.

ProSYS User Guide

15

16

Keys

The keys on the keypad can be used for a variety of functions. Each key is explained below.

NOTE:

For detailed information regarding the keys of the Touchscreen keypad, refer to the ProSYS Touchscreen Keypad Instruction manual that is included with the product.

Numerical Keys

Numerical keys (0-9) are used to input the numeric codes that may be required for setting, unsetting, and triggering emergency alarms, along with several other special functions.

Control Keys

The functions of the other keys on the keypad vary according to the current mode. The following table lists the functions of the keys in

Normal Operation

mode and when using the

User Functions

menu:

Key

/

Normal Operation

Activates the

User

Functions

mode.

User Functions

Exits from the current menu and returns to

Normal

Operation

mode.

Changes data.

/

/

Activates the

Full

mode,

Group Setting and Full

Quick Setting.

Activates the

Night Set

mode and Night

Quick Setting.

Unsets the system after the user code is entered.

Changes data.

Terminates commands and confirms data to be stored.

Provides the system status.

Scrolls up a list/moves the cursor to the left.

Omits zones and provides information on omitted zones (must be pressed after entering a user code).

ProSYS User Guide

Scrolls down a list/moves the cursor to the right.

Emergency Keys

Your keypad provides three sets of emergency keys, which can be pressed whenever the police, fire department, or auxiliary assistance is required.

NOTE:

Your engineer should define the operation of the emergency keys.

Panic Emergency

/

Pressing both keys simultaneously, and for at least two seconds, will activate a

Panic Emergency alarm.

Fire Emergency

Pressing and simultaneously, and for at least two seconds, will activate a

Fire Emergency alarm.

Auxiliary

Emergency

/

Pressing and simultaneously, and for at least two seconds, will activate an

Auxiliary Emergency alarm.(Medical)

/

The annunciation that results during these emergency alarms, along with other system sounds, is described on page 69

.

If your system has been programmed to do so, it will communicate any or all of these alarms to the ARC monitoring your installation. System programming also determines whether these emergency alarms will be audible and/or capable of being communicated to the ARC.

Function Keys (A, B)

By default, Function keys are used to set groups of zones, as defined by your engineer and described on page 25. Function keys can also be used to activate a pre-recorded series of commands, as described on page 53.

ProSYS User Guide

17

18

Quick Key Operation

The Quick Key Operation is a short effective way that helps you to easily operate your system and quickly activate user functions, skipping the user code. For example, to set the system, simply press the key.

NOTE:

For quick key operation your engineer has to define quick key operation.

LCD Status Display

The LCD status display will vary depending on the number of partitions in your system.

If your system is defined with only one partition, the LCD displays the partition name, time and date.

If your system has 2 or 3 partitions, the LCD displays the system name, date, time and the status of each partition. A status letter represents the partition’s status, as follows:

SE

: Partition is set

NR

: Partition Not Ready

AL

: Partition in Alarm

PS

: Partition is set in Part set mode

R

: Partition Ready

LCD Blank Display

If defined by your engineer two minutes after the last keypad operation the keypad will be disabled and the following display will appear on the

LCD:

To release the keypad and return to normal operation mode press:

[CODE] +

-or-

Present the Proximity Tag to Set/Unset the system.

NOTE:

During Blank Display mode the Ready LED indicates a fault in the system.

ProSYS User Guide

Chapter 3: Setting and Unsetting the

System

Setting

Setting your system enables its intrusion detectors to trigger an alarm when violated.

You can set your system by code setting, in which you need to use your user code, or you can use quick setting (without using a code)

NOTE:

If during code setting you enter a wrong user code, the keypad produces three short beeps. Press [ correctly.

] [

] quickly and re-enter the sequence

Before setting your system check the Ready LED. If it is lit or flashing, the system is READY to be set. If NOT the system is NOT ready to be set. In this case, secure or omit the violated zone(s), and then proceed

Remember, fire protection and the protection offered by the keypad's emergency keys are always available (if authorised by your engineer)

NOTE:

If defined by your enginner, your system can be defined to for Force setting. This definition sets the system regardless of open zones when using a keyswitch or automatic setting.

Note that force setting the system results in leaving partition(s) unsecured

.

Your ProSYS offers the following kinds of settings:

Ê

Full

, page 20

Ê

Partial

, page 22

Ê

Partition

, page 23

Ê

Group

, page 25

Ê Quick

, page 26

Ê

Blank Display

, page 26

ProSYS User Guide

19

Full Setting

Full setting prepares

all

of the system's intrusion detectors to trigger an alarm, if violated, and is used when leaving the premises empty.

NOTE:

Before setting the panel all open zones must be closed.

The installation company can program your system to full set using one of the following:

Timed Exit

: After entering your code, the alarm system will set after a predefined exit time delay. This will help you to leave via the exit route without interfering with the setting process.

NOTE:

The exit delay time can be extended once, to the time defined by the exit delay, by pressing the key during the exit delay time.

Final Exit

: After entering your code, the system will go to Full Set 10 seconds after the final exit door is closed.

Exit Terminator

: After entering your code, the system will go to Full

Set 10 seconds after you press the Exit Terminator button (a push button normally mounted outside the premises).

To Full Set:

1)

Check the

Ready

LED on your keypad. If it is constantly lit, the system is READY to be set.

20

If the

Ready

LED is not lit the system is not ready to be set. In this case, secure or omit the violated zone(s), as described on page 22, and then proceed.

If the

Ready

LED is flashing, there are faults in the system that need to be confirmed before continuing with the Full SET process. (Ask your engineer if defined.)

2)

THE JONESES

05:42 DEC 16 TUE

Hold the tag close to the keypad's keys or

Enter your user code and press .

NOTE:

If required, all faults in the system should be confirmed to enable the setting operation. Scroll down the list of fault/s using the key. At the end of the list the following question will appear: « OVERIDE FLT? » Use the key to toggle the option to Y and press .

ProSYS User Guide

NOTE:

3)

If defined by your engineer press for quick setting

NOTE:

If you make a mistake, the keypad produces three short beeps. If so, press

quickly and re-enter the above sequence correctly.

All persons are to exit via the authorized exit route.

THE JONESES

A continuous sound will sound from the keypad’s buzzer and internal sounder. The

Set

LED flashes while the system counts down the Exit Delay time period (shown in the bottom right of the LCD). The exit tone will change if any detectors are violated during exit time.

The system is set when the exit time has expired, on activation of the Final Exit zone or when the Exit Terminator button is pressed.

The

Set

LED will light and a confirmation message will appear for the time defined by your installation company. After that time the display will return to the partition status display. The strobe will activate for

10 seconds, indicating a successful set of the system (if defined).

NOTE:

During the exit time, a zone outside the exit route can prevent setting of the system or can trigger an alarm from the keypad and the internal speaker (as defined by your installation company).

ProSYS User Guide

21

Part Setting

Part Setting

activates only perimeter detectors (as programmed by your engineer), enabling individuals to remain inside and move about the premises even after the system is set.

To Part Set:

1)

Check the Ready LED and make sure that the system is ready for Part (Night) setting).

2)

THE JONESES

05:42 DEC 16 TUE

Hold the tag close to the keypad's keys or

Enter your user code and press

.

NOTE:

If required, all faults in the system should be confirmed to enable the setting operation. Scroll down the list of fault/s using the list the following question will appear: « OVERIDE FLT? » Use the to toggle the option to Y and press ..

key. At the end of the key

NOTES:

Press twice to cancel the Entry Delay time period. The display will show a confirmation message “NO Entry Delay”.

Press keypad.

during the Exit Delay time period to silence the beeps from the

If you make a mistake entering your user code, the keypad produces three short beeps. Press quickly and re-enter the above sequence correctly.

3)

If defined by your engineer press for quick Part setting

If required, leave the premises via the

P.SET: EXIT = O:45

authorized exit route and close the door.

During the Exit Delay time period a continuous sound will sound from the keypad’s buzzer, the

Set

LED flashes, and the

Omit

LED lights, indicating that the interior zones are being omitted. The exit tone will change if any detectors are violated during exit time.

If so programmed, the system will be part set when the exit time has expired, on activation of the Final Exit zone or when the Exit

Terminator button is pressed.

22

ProSYS User Guide

THE JONESES

AT PART SET

When the system is set, the

Set

and

Omit

LEDs will light together with a confirmation message that will appear on the LCD for the time defined by your engineer.

After that time the display will return to the partition status display and the

Power

and

Ready

LEDs light steadily.

The strobe will activate for 10 seconds indicating a successful set of the system (if defined).

Partition Setting

One of the advantages of ProSYS is its ability to divide any system into a number of partitions. Each partition may be viewed as a separate security system, each of which can be set and unset individually regardless of the condition of the other.

Partitions can be set/unset one at a time or all at once, and can be set in Part Set or Full Set.

Keypads and Partitions -

Each keypad is assigned to different partition(s). The Grand Master and the Manager (with access to all partitions) can use any keypad to access any partition. Other users can use only designated keypads.

NOTES:

Common Zones - Partitioned systems can share common zones. For example, a shared front door to two family houses must be available to both families and is therefore shared between them.

A common zone(s) is set only if all partitions sharing the zone(s) are set. The common zone(s) is unset if any of the partitions, to which the zone(s) is assigned, is unset.

If the system is defined to work in Area mode, the common zone will be set if any partition sharing the zone is set. The common zone will be unset if all the partitions sharing the zone are unset.

For more information about common zones refer to your engineer.

ProSYS User Guide

23

Setting Multiple Partitions

Only users that have been defined to operate multiple partitions during the system installation can operate more than one partition and set/unset all partitions at once.

To Full Set multiple partitions:

1)

Check the

Ready

LED status as described on the Full Setting procedure on page 20 and then proceed.

2)

THE JONESES

05:42 DEC 16 TUE

Hold the tag close to the keypad's keys or

Enter your user code and press .

3)

NOTE:

If required, all faults in the system should be confirmed to enable the setting operation.

Scroll down the list of fault/s using the question will appear: « OVERIDE FLT? » Use the press .

key. At the end of the list the following key to toggle the option to Y and

Select the number of the partition you want to set.

-OR-

Select

0

to set ALL partitions.

4)

Press to set the selected partition(s).

5)

Repeat the above steps to set additional partitions.

The partition(s) will be set when the exit time has expired, on activation of the Final Exit zone, or by pressing the Exit Terminator button.

NOTE:

To perform a Part set for a partition use the key instead of the key).

Examples:

Ê

To set partition 3 with code 1234:

1-2-3-4

Ê

To set ALL partitions:

1-2-3-4

Ê

To set partitions 3 and 4:

1-2-3-4

[0]

[3] [4]

Ê

To set partition 3 in

Part Set

mode:

1-2-3-4

[3]

[3]

24

ProSYS User Guide

Group Setting

Group setting enables you to set a number of zones within a partition, using the Function keys. Ask your engineer about defining groups.

To set a group (if the system has one partition):

1)

Enter your code, followed by the Function key corresponding to the group(s) you want to set. The selected group is set.

For example, to set Group A, enter:

[Code] [A]

.

NOTE:

If there are faults in the system that need to be confirmed, follow the same procedure described in step 2 of Full Setting, see page 20.

If Macros are being used, this option is not available.

When the group is set, the Set and Omit LEDs will light together with a confirmation message that will appear on the LCD for the time defined by your engineer.

After that time the display will return to the partition status display and the

Power

and

Ready

LEDs light steadily.

2)

To set another group, repeat step 1.

To set a group (if your user code is assigned to more than one partition):

1)

Enter your user code, then the group letter, then the partition number, and the group letter again.

For example, to set Group A, enter:

[Code] [A] [Partition No] [A]

.

2)

To set another group, repeat step 1.

NOTE:

If your system is defined with Quick Setting, press the Function key corresponding to the group(s) you want to set. The selected group(s) is set.

ProSYS User Guide

25

Quick Setting

Quick setting enables you to set the system with the press of a single key.

NOTES:

Your engineer should define the Quick Setting feature.

For a system with multiple partitions, only the partition that the keypad is located in will be set for Full Set or Part Set when the pressed.

key or key is

To quick set using Full setting:

Ê

Hold the tag close to the keypad's keys or press system (or partition) is fully set.

. The

To quick set using Part Set setting:

Ê

Hold the tag close to the keypad's keys or press . The system's (or partition's) external detectors are activated.

To quick set a group:

Ê

Press the Function key corresponding to the group(s) you want to set. The selected group(s) is set.

NOTE:

For a system with multiple partitions, the group inside the partition that the keypad is located in will be set.

Setting in Blank Display Mode

To perform setting while the system is in Blank Display mode:

1)

Release the keypad by pressing

[CODE] +

2)

Within 2 minutes time press:

For Full setting.

For Partial setting.

Keyswitch Setting

If your system is equipped with a special keyswitch, it can, with the twist of a key, be toggled through

Full Set

and

Unset

modes.

26

ProSYS User Guide

Wireless 4-Button Key Fob Setting

The system can be set using a button on a wireless 4-button key fob. Your engineer programs this option. Refer to the instructions supplied with your 4-button key fob for more information.

Unsetting

Unsetting your system deactivates its detectors. Unsetting can be performed from any keypad, using a Keyswitch, a wireless button key fob or automatically, if so defined. Remember, fire protection and the protection offered by the keypad's emergency keys are always available.

Your ProSYS offers the following kinds of unsetting:

Ê

Unsetting the System

, page 27

Ê

Unsetting After an Alarm

, page 28

Ê

Resetting After an Alarm

, page 29

Ê

Partition Unsetting

, page 29

Ê

Duress Unsetting

, page 31

Ê Disabling a Fire Alarm

, page 32

Unsetting the System

Unsetting deactivates all detectors in the system.

To unset the system:

1)

If outside the premises, open an "entry" door. The keypad(s) beeps, indicating that the Entry Delay Time period has begun.

2)

Before the Entry Delay time period expires, hold the tag close to the keypad's keys or enter your user code and press

LCD.

. An « Unset » message display will appear on the

NOTE:

If you make a mistake when entering your user code, the keypad will produce three short beeps. If so, re-enter the sequence correctly.

ProSYS User Guide

27

Unsetting After an Alarm

If an alarm has occurred, it will be indicated by the keypad. Once the cause of the alarm has been established the system must be reset.

To unset an alarm using a user code:

1)

If outside the premises, open an "entry" door. The keypad(s) beeps, indicating that the Entry Delay period has begun.

2)

Observe the keypad. If The

Set

LED is flashing, and the display shows the activated partition, an alarm has occurred. Pressing the partition and zone. key will show the activated

3)

Hold the tag close to the keypad's keys or enter your user code and press . If an alarm occurred, the SET LED will flash. Scroll through the list of alarm zones. To To exit the

Alarm Memory

mode before the timeout has expired, press .

4)

Proceed to

“Resetting after an Alarm

NOTES:

It is recommended to leave the premises. Only after police investigation should you assume that the burglar is no longer on the premises and safely re-enter.

In special cases (if programmed so during installation), setting the system after an alarm requires a technician code. On the LCD, a Call Engineer message will appear (see Resetting after an Alarm).

IMPORTANT:

If the alarm was caused by a tripped smoke detector(s), the keypad's Fire

LED will remain lit, providing an indication that the fire system must be reset before it will be capable of detecting subsequent alarms. Furthermore, until it is reset, you will be prevented from setting your system.

To reset a smoke detector, press

[2] [2] [user code]

.

Press to exit the User Functions mode.

28

ProSYS User Guide

Resetting after an Alarm

Your installation company can define that the reset of the system to a

Normal Operation mode will require the intervention of your ARC or engineer. In this case, after an alarm condition, the display will show

"

Call Engineer”

message along with the contacting information as defined by your engineer

Consult your engineer regarding the type of reset mode that your system is set for, Remote Reset or Engineer Reset.

NOTE:

Before attempting to reset your system ensure that the system is unset.

Anti Code Reset

1)

Pressing on the will enter you to the Anti Code section. Press

Anti Code option. key while the "Call engineer" display is on

to enter the

2)

Call your ARC or engineer and quote the “

RANDOM CODE

” displayed on your keypad. The ARC or engineer will give you a return Anti-Code.

3)

Enter this Anti code followed by and the system will reset.

Engineer Reset

Your Alarm Receiving Center (ARC) or engineer can reset your system remotely or locally.

To enable local reset by your engineer you need to authorize him as follows:

1)

Press

[2

][0][3] while the "Call engineer" display is on.

2)

Enter Grand master, Master or Manager code followed by

. The following display appears:

3)

Use the to select

[Y]

and press . A one hour time window is opened for the engineer to program user functions and be able to reset your system locally (Quick key

[*][2][0]4]

from the main user menu).

ProSYS User Guide

29

Partition Unsetting

Partition unsetting enables you to unset individual partitions within a set system.

To unset partitions:

1)

Enter your user code and press

2)

Select the partition number:

For ProSYS 40 partition 1-4.

.

For ProSYS 128 partition 1-8.

-OR-

To unset all partitions at once, select

0

.

-OR-

For an LCD keypad, scroll with the or the required partition (or enter the partition's number).

key to the

3)

Press to confirm. A confirmation message will be displayed for several seconds.

4)

Repeat the above steps to unset other partitions.

Examples:

Ê To unset partition 3 with code 1234: 1-2-3-4

Ê

To unset ALL partitions: 1-2-3-4

[0]

[3]

Ê

To unset partitions 3 and 4: 1-2-3-4

[3] [4]

NOTES:

ALL partitions relates to all partitions that are authorized by the security code in use.

If the Set LED is flashing after unsetting, check the display for activated

(alarmed) zones before proceeding.

30

ProSYS User Guide

Duress Unsetting

If you are ever coerced into unsetting your system, you can comply with the intruder's wishes while sending a silent duress alarm to the

Alarm Receiving Centre. To do so, you must use a special duress code, which when used will unset the system in the regular manner, while simultaneously transmitting the duress alarm.

NOTE:

To comply with UK local police requirements, by default the Duress alarm is not reported to the ARC.

To use a duress code, add

1

to the last digit of your user code, as shown in the table below:

User Code Duress Code

1-2-3-4 1-2-3-5

5-6-7-8 5-6-7-9

6-7-8-9 6-7-8-0

NOTES:

Under no circumstances should the duress code be used haphazardly or without reason. ARCs, along with Police Departments, treat duress codes very seriously and take immediate action.

To unset using a duress code:

1)

If outside the premises, open an "entry" door. The keypad(s) beeps, indicating that the Entry Delay time period has begun.

2)

Enter your duress code and press . The system is unset, and a silent alarm is sent to the Alarm Receiving

Centre.

ProSYS User Guide

31

Disabling a Fire Alarm (Switch Auxiliary)

Unsetting the fire alarm interrupts the power supplied to the system's smoke detector(s) for a predetermined interval, thus resetting and

"readying" them for subsequent alarms.

NOTE:

You may need to perform this procedure several times in order to prevent the smoke detector(s) from re-detecting any remaining smoke.

To disable the fire alarm:

1)

USER FUNCTIONS:

1) OMIT

From the

User Functions

menu, select

[2] Activities

.

2)

ACTIVITIES:

1) PROG OUTPUT

Select

[2] Switch Auxiliary

.

3)

Enter your user code.

DONE

HIT ANY KEY

The fire alarm is disabled for a predefined amount of time.

32

ProSYS User Guide

Chapter 4: Omitting a Zone

[1] [1] [CODE] [Zone No.]

When an intrusion zone is not secured, the keypad's

Ready

LED will not light (unless there is a fault in the system), nor can the system be readily set. If programmed by engineer, you can omit zones in order to set a partition even if a zone within that partition is open/not secured.

You may want to omit a zone when access is needed to one zone in an otherwise protected area, or to cause the system to temporarily circumvent a zone containing damaged wiring until repairs can be made.

WARNING:

An omitted zone may reduce the system's security capability.

Before performing the following procedure, identify the faulty zone(s) as follows:

Enter the view zone status option in location [3][4] and then scroll down with the down arrow key to view all "not ready" zones. The LCD only displays "not ready" zones that belong to the user code that was entered.

To change a zone's omit status:

1)

THE JONESES

05:42 DEC 16 TUE

From the Normal Operation mode, enter your code and press is illuminated.

. The

Omit

LED

NOTE:

If you make a mistake when entering your user code, the keypad will produce three short beeps. Re-enter the sequence correctly.

2)

OMT Z=001 (CL)N

ZONE 001

Enter the zone number.

Entering the zone number a second time un-omits it (toggle action).

An additional zone(s) can be omitted at the same time by adding its number to the sequence. For example, to omit zones

2 and 13 using code 1234, enter:

1-2-3-4 02 13

ProSYS User Guide

33

To un-omit zone 2 only using code 1234, enter:

1-2-3-4 02

3)

When finished entering zone numbers, press .

NOTES:

Omitting zones is effective for one set only. All zones are automatically un-omitted when the system is set and then unset again.

The Omit LED turns off when setting in Full Set mode.

Omitting a zone can also be performed from the User Fuctions menu as follows: Press

[1] [1] [CODE] [Zone No.]

34

ProSYS User Guide

Chapter 5: Activating Programmable

Outputs

[2] [1] [CODE] [PO No.]

You can place a household appliance, such as heating, lighting or an external device, under the control of the ProSYS, enabling it to be conveniently turned on and off automatically, or by user commands from any system keypad, SMS, keyfob or by the phone.

There are two types of appliances, each of which behaves differently when activated:

Ê

Latched appliance:

Remains activated until it is deactivated.

Ê

Pulsed appliance:

Remains activated for a predefined time, after which it is automatically deactivated.

Ask your engineer which of your appliances are defined as latched and which are defined as pulsed.

There are two ways to activate home appliances from the keypad:

Ê

From the

User Functions

menu press

[2] [1] [CODE]

[PO No.]

and activate / deactivate the selected output.

Ê

Enter a code defined by your engineer that is used only to operate outputs (PO authority level).

ProSYS User Guide

35

Chapter 6: Follow-Me Report

[2] [7] [CODE] [FM No.]

In the case of an alarm or event, the system can initiate a phone call to a designated telephone or pager, send SMS or send an Email and employ unique tones or messages to express the active event.

Your engineer defines the type of reporting to a follow me destination.

Consult your engineer for the possibility to report events by SMS or

Email.

To enter/edit a Follow-Me destination:

1)

USER FUNCTIONS:

1) OMIT

From the

User Functions

menu, select

[2] ACTIVITIES

.

2)

ACTIVITIES:

1) PROG OUTPUT

Select

[7] FOLLOW ME

.

3)

Enter your user code and press .

4)

Select the FM index number you want to edit.

5)

Enter the phone number or email address.

36

After entering a phone number, two questions are displayed.

These questions enable you to define the permission assigned to the designated phone when the Advanced Voice Module is connected to the system. FM phone numbers can also be used for remote operation. Refer to the

Voice Module

Programming and Operations Manual

for more information.

6)

ENABLE FM NO.

1:

REMOTE PROGRAM: N

Select one of the following options to define the permission:

Y:

The user on the FM phone can enter the

Remote Operations

menu and perform set, unset; zone omitting, output activation, FM phone editing, and remote listen and talk operations.

N:

The user on the FM phone cannot enter the

Remote Operations

menu.

ProSYS User Guide

7)

ENABLE FM NO.

REMOTE LISTEN:

1:

N

Select one of the following options to define the permission:

Y:

The user on the FM phone can perform remote listen in and talk operations from the

Acknowledgement

menu.

N:

The user on the FM phone cannot perform listen and talk operations from the

Acknowledgment

menu. Refer to the

Voice Module Programming and

Operations Manual

for more information.

If required, when defining a telephone number (max 32 digits), include the special functions described below to achieve the related effect. You can press the or keys to toggle to the required character.

Function Sequence Results

Stop dialling and wait for a new dial tone.

[1]

A

Wait a fixed period before continuing.

[2]

B

Switch from

Pulse

to

Tone

(or from

Tone

to

Pulse

).

Send the DTMF

¾

character.

[3]

[7]

C

¾

Send the DTMF # character.

[9]

#

Delete numbers from the cursor position.

[0]

NOTE:

To delete a number, place the cursor in the first position and press [0].

When you have completed your entry, press to store it.

ProSYS User Guide

37

Chapter 7: User Codes

[5] [CODE] [1]

To perform many of the ProSYS's functions, a security code (often called a user code) must be be used.

Each individual using the system is assigned a user code, which, in turn, is linked to an Authority Level. Those with a "higher authority" have access to a greater number of system functions, while those with a "lower authority" are more restricted in what they may do. There are eight different Authority Levels available for users of the ProSYS, as described on page 41.

User codes may have variable lengths up to 6 digits. The ProSYS can support up to 99 user codes (ProSYS 128) or up to 60 user codes

(ProSYS 40).

Your ProSYS was given a Grand Master Code of

1-2-3-4-0-0

during manufacturing. Unless your engineer has already changed it to suit your preference, it is best to change this code to one that is unique and personalized. To change the Master Code, and/or define User codes, follow the procedure in the following section.

NOTE:

To define the authority levels refer to your engineer.

Defining and Changing User Codes

[5] [CODE] [1]

The user assigned the Grand Master Authority Level can change all user codes but cannot view the digits in the user codes. Users with other Authority Levels can change only their own codes.

The system must be unset in order to change/edit user codes.

To change a user code:

1)

USER FUNCTIONS:

1) OMIT

From the

User Functions

menu, select

[5] Access Code

.

2)

Enter your

6-digit

Master or Grand

Master code, and press .

38

ProSYS User Guide

3)

4)

ACCESS CODE:

1) UPDATE CODES

Select

[1] Update Code

.

Enter the two-digit User Index number to which you want to assign a user code.

For example, to assign a user code to user index number

6

, press

[0] [6]

.

NOTES:

In ProSYS 128 systems, the User Index number is from 00 to 98.

In ProSYS 40 systems, the User Index number is from 00 to 59.

The User Index number 00 belongs to the Grand Master user code.

5)

CODE 06, USER

ENTER: 0

Enter a six-digit code and press

6)

.

If successful, a single confirmation beep is sounded, and a message is displayed. If not, three quick error beeps are sounded.

7)

SELECT CODE:

07) 0 USER

Repeat the above steps for additional codes until complete.

8)

When all codes have been entered press reset and exit the

User Functions

menu. quickly to

ProSYS User Guide

39

Deleting User Codes

At times, it may be desirable to completely delete a

user code

. Note that it is impossible to delete the Master Code (although it can be changed).

The system must be unset in order to delete user codes.

To delete a user code:

1)

Follow steps 1-3 in the previous procedure.

2)

CODE 1234 GRAND

00) USER 00

Enter the two-digit User Index number for which the code is to be deleted.

For example, to delete the user code assigned to user index number 6, press

[0] [6]

.

3)

Press

[0]

followed by .

4)

CODE 06, USER

ACCEPTED

If successful, a single confirmation beep is sounded, and a message is displayed. If not, three quick error beeps are sounded.

5)

Repeat the above steps for additional codes until complete.

6)

When all required codes have been deleted, press quickly to reset and exit the

User Functions

menu.

40

ProSYS User Guide

User Authority Levels

[5] [CODE] [2]

Each individual using the system is assigned a user code, which, in turn, is linked to an Authority Level. Those with a "higher authority" have access to a greater number of system functions, while those with a "lower authority" are more restricted in what they may do. There are nine different Authority Levels available for users of the ProSYS, as described below.

Level Description

GRAND

MASTER

All operations for all partitions. There is only one

Grand Master code in the system, and it is designated as

00

. The Engineer or the Grand

Master can change this code.

MANAGER

All operations for all partitions. There is only one

Manager code in the system, and it is designated as

01

.

MASTER

All operations for designated partitions only. The user holding the Master code can change the

Master code and the codes of all Authority

Levels lower than Master. There can be any number of Master codes in the system.

USER

SET ONLY

Only basic operations to one or more partitions.

Setting one or more partitions.

Set Only codes are useful for workers who arrive when the premises are already open but, because they are the last to leave, they are given the responsibility to close the premises.

CLEANER

Used only for one-time setting and unsetting, after which the code is automatically erased and should be redefined. This code is typically used residentially for cleaners, home attendants, and repairmen who must enter the premises before the owner(s) arrive.

UN

OMITTABLE

Basic operations to one or more partitions without the ability to omit zones.

ProSYS User Guide

41

Level Description

GUARD

Typically used to enable a guard to unset the system for a predefined amount of time. After this time, the system is automatically set again.

PO CTRL

Typically used to enable the operation of a device controlled by a Programmable Output

(meaning a door and so on). These codes are used only to operate Outputs.

Entering User Labels

[*] [5] [CODE] [#] [4]

- Engineer or Grand Master

You can rename the labels that identify users by changing the default labels (User 1, User 2 and so on) to the names of the users themselves.

¾

To enter a user label:

1)

USER FUNCTIONS:

1) OMIT

From the

User Functions

menu, select

[5] Access Code

.

2)

Enter your 4-digit or 6-digit Master or Grand Master code and press

.

3)

ACCESS CODE:

1) UPDATE CODES

Select

[4] User Label

.

4)

Select the index number of the user code that you want to label, and enter a name for the selected user, as described in the character table.

42

ProSYS User Guide

To enter a new label:

Use the keys on the keypad to produce characters according to the table below. Pressing a particular key toggles between the characters available from that key in the sequence listed below followed by a blank space. The ProSYS permits a total of 74 characters (letters, numbers, and symbols) for use in labeling.

NOTES:

The data sequence of each key in the following table is suitable only for the

English version.

1

1 A B C D E F G H I J K L M

2

2 N O P Q R S T U V W X Y Z

3

3 ! '' & ' : – . ? / ( )

4

4 a b c d e f g h i j k l m

5

5 n o p q r s t u v w x y z

6 - 0

Each of these keys toggles between producing their number and a blank space.

Use this button to toggle forward through the available characters.

Use this button to toggle backward through the available characters.

To move the cursor to the left, press the UP arrow button

To move the cursor to the right, press the DOWN arrow button

.

.

.

To enter a completed label into the system, press

ProSYS User Guide

43

Assigning Dual Codes

[*] [5] [CODE] [#] [7]

Dual codes are a high-security option that ensures that the system is unset only by pairs of users. This prevents individual users from unsetting the system alone, by making their user code or proximity tag active only if accompanied by their partner's user code or proximity tag. To unset the system, two users must enter their codes or pass their proximity tags one after the other The time between entering the two user codes is 60 seconds.

NOTES:

Your engineer must enable the Dual Code feature.

When using the Dual Code feature, there will not be a restriction in operating with one user through the Access Control module.

The Cleaner, Set Only, PO Only, and Guard authority levels cannot be used to perform dual-code unsetting.

¾

To assign dual codes:

1)

USER FUNCTIONS:

1) OMIT

From the

User Functions

menu, select

[5] Access Code

.

2)

Enter your user code, followed by .

3)

ACCESS CODE:

1) UPDATE CODES

Select

[6] Dual Codes

.

4)

Select the index number of the dual code that you want to assign.

5)

Enter the user index numbers of the users you want to pair together for the dual code, and press .

44

ProSYS User Guide

Chapter 8: Viewing Fault Conditions

[3] [1] [CODE]

A rapid flashing of the

Ready

LED indicates a fault condition. The following procedure describes how to identify the fault condition. Refer to the table on page 67 for a list of possible fault conditions and their descriptions.

The system must be unset to view fault conditions.

To view fault conditions:

1)

USER FUNCTIONS:

1) OMIT

From the

User Functions

menu, select

[3] View

.

2)

Select

[1] Fault

.

3)

Enter your user code and press

. The first fault condition is displayed.

4)

FAULT

MAIN: LOW BATT

If an (

L

) appears, other faults exist.

Scroll down to view additional faults.

NOTE:

In some cases, you may be able to correct faults and restore the system to Normal Operation mode yourself. In other cases, your e (or other related services) may be required. When all outstanding faults are resolved, the rapidly flashing Ready LED on your keypad(s) lights steadily, and all evidence of the faults is automatically removed from your system.

ProSYS User Guide

45

Chapter 9: Defining and Changing

System Time and Date

[6] [Grand Master Code] [1] / [2]

The correct time and date must be set to ensure proper operation of the ProSYS.

Defining and Changing System Time

The system time is set and changed from the

Set Clocks

menu.

To define/change the system time:

1)

From the

User Functions

menu, select

[6] Clocks

.

2)

Select

[1] System Time

.

3)

Enter the Grand Master code and press

4)

Enter the correct time in 24-hour format.

.

Defining and Changing System Date

The system date is defined and changed from the

Set Clocks

menu.

To define/change the system date:

1)

From the

User Functions

menu, select

[6] Clocks

.

2)

Select

[2] System Date

.

3)

Enter the Grand Master code and press

4)

Enter the correct date. Use the and the

.

keys to move the cursor and the options. key to toggle between the

46

ProSYS User Guide

Chapter 10: Scheduling Weekly

Programs

[6] [Grand Master Code] [5]

Scheduling weekly programs enables you to automate some system operations. This is performed by defining up to two time intervals per day, during which the system automatically performs one of the following functions:

Ê

Automatic Setting/Unsetting

, below

Ê

Automatic PO Activation

, page 49

Ê

User Limitation

, page 51

You can define automatic time intervals for every day in the week, or individual days in the week. When performing this procedure, use the data that you prepared in the table provided in

Appendix C: Scheduling Tables

, page 71.

Automatic Setting/Unsetting

A setting program automatically sets and unsets the system at predefined time intervals.

When defining the automatic setting/unsetting program, you need to define the following parameters:

Partition

,

Setting Mode

,

Time

, and

Label

.

To define an automatic setting/unsetting program:

1)

USER FUNCTIONS:

1) OMIT

From the

User Functions

menu, select

[6] Clocks

.

2)

Enter the Grand Master code and press

.

3)

4)

5)

SCHEDULER:

01) SCHEDULE 01

SCHEDULE 01:

01) SET/UNSET

Select

[5] Scheduler

.

Select a program.

Select

[1] Set/Unset

.

ProSYS User Guide

47

48

6)

SET/UNSET S:01

1)

PARTITION

7)

Y -------

8)

2) SETTING MODE

9)

10)

11)

P .SET=ABCD

S:01 _

_ _ _ _

SET/UNSET S:01

3)

DATE/TIME

Select

[1] Partition

.

Use the key to enter

Y

under each partition that will be automatically set and unset.

Select

[2] Setting Mode

.

Select one of the following options:

[1] Full Set:

To fully set the system.

Proceed to step 11.

[2] Part Set:

To set the system's external detectors. Proceed to step 11.

[3] Group:

To set groups within the assigned partitions. Proceed to step 10.

Use the key to enter

Y

under each group that will be automatically set and unset.

Select

[3] Date/Time

.

12)

SELECT A DAY

1) MONDAY

Select

[1] Monday

.

-OR-

Select

[8] All

to set the same time intervals for every day in the week.

13)

14)

MON:SET1 S:01

00:00

MON:UNSET1 S:01

00:00

Enter the first time at which the system is set on Monday.

Enter the first time at which the system is unset on Monday.

ProSYS User Guide

15)

MON:SET2 S:01

00:00

Enter the second time at which the system is set on Monday.

16)

MON:UNSET2 S:01

00:00

Enter the second time at which the system is unset on Monday.

NOTE:

Leave the time at 00:00 if you do not want to perform the automation during the current interval for the current day.

17)

Define intervals for Tuesday and the rest of the week, as described in steps 12-16 above.

18)

19)

20)

SET/UNSET S:01

4) LABEL

SCHEDULE LABEL:

SCHEDULE 01

SCHEDULER:

02)

SCHEDULE 02

After you have defined the last day or all days in the week, you define a label for the weekly program.

Select

[4] Label

.

Enter a name for the scheduling program.

Define additional scheduling programs, as required.

Defining a PO Activation Program

A PO (programmable output - home appliance) activation program automatically activates and deactivates POs during your required intervals. In each program, you can define four POs to operate simultaneously.

When defining a PO activation program, you need to define the following parameters:

POs

,

Time Schedule

,

Holiday,

and

Label

.

To define a PO activation program:

1)

USER FUNCTIONS:

1) OMIT

From the

User Functions

[6] Clocks

.

menu, select

2)

Enter the Grand Master code and press .

ProSYS User Guide

49

3)

Select

[5] Scheduler

.

4)

SCHEDULER:

01)SCHEDULE 01

Select a program, other than those already being used for automatic setting or user limitation.

Select

[2] PO On/Off

.

5)

SCHEDULE 02:

1) SET/ UNSET

6)

PO ON/OFF S:02

1) PROG OUTPUTS

Select

[1] Programmable Outputs

. In this option, you select the PO that will be operated in this scheduling program.

7)

PROG OUTPUT S:02

01)

OUTPUT 01 N

Specify whether or not the first PO in the list should be automatically activated by using the key to enter one of the following characters at the end of the second line in the LCD:

Y:

Automatically activated.

N:

Not automatically activated.

8)

Specify whether the three remaining POs in the list should be automatically activated by selecting them and following step 7 above.

9)

Select

[2] Date/Time

1) PROG OUTPUTS

10)

Define time windows for the week, as described in step 12 on page 48.

11)

1) PROG OUTPUTS

Select

[3] HOLIDAY

. In this option, you define the way in which the group of POs is activated during a holiday period.

50

ProSYS User Guide

12)

PO HOLIDAY S:01

YES/NO? N

N:

During holidays, POs are activated in the same way as defined in the time windows of the week.

Y:

POs are activated during the holiday according to the time schedule defined in the next step (holiday definition).

NOTE:

If all the time intervals during the holiday are defined as 00:00, then the POs are not activated during the holiday.

13)

SCHEDULE LABEL:

SCHEDULE 03

Enter a name for the scheduling program.

14)

03) SCHEDULE 03

Define additional weekly programs, as required.

Defining a User Limitation Program

A user limitation program automatically prevents certain users from unsetting the system during specified time intervals. By default, all users of the system operate without this limitation.

When defining a user limitation program, you need to define the following three parameters:

Users

,

Time Schedule

, and

Label

.

NOTE:

By default, all users are not restricted.

To define a user limitation program:

1)

USER FUNCTIONS:

1) OMIT

From the

User Functions

menu, select

[6] Clocks

.

2)

Enter the Grand Master code and press .

3)

4)

SCHEDULER:

01)SCHEDULE 01

Select

[5] Scheduler

.

Select a program other than those already being used for automatic setting or PO activation.

ProSYS User Guide

51

5)

6)

7)

8)

SCHEDULE 03:

1) SET/ UNSET

USER LIMIT S:03

01) USER 01 N

USER LIMIT S:03

1) USER NUMBER

Select

[3] User Limit

.

Select

[1] User Number

.

Specify whether or not each user in the list should be automatically restricted from unsetting the system by using the key to enter one of the following characters at the end of the second line in the LCD:

Y:

Automatically restricted.

N:

Not automatically restricted.

Select

[2] Date/Time

.

9)

10)

SELECT A DAY

1) MONDAY

11)

SCHEDULE LABEL:

SCHEDULE 03

12)

SCHEDULER:

04)

SCHEDULE 04

Define time windows for the week, as described in step 12 on page 48.

Select

[3] Label

.

Enter a name for the weekly program.

Define additional scheduling programs, as required.

52

ProSYS User Guide

Chapter 11: Programming Function Keys

[9] [Grand Master Code] [5]

The ProSYS enables you to record a series of commands and assign them to a Function key. When the Function key is pressed, the recorded commands are executed from beginning to end.

NOTE:

The default function for all Function keys is group setting, as described on page 25.

If Group setting is used, this option is not available.

Before programming a Function key, it is recommended to perform your required series of commands, making a note of every key you press while doing so. These keys will be entered in the form of characters in step 4 of the procedure for programming the Function key.

For example, to set partitions 1 and 2 in a 3-partitioned system, you would press the following keys in step 4:

CODE

This example requires the following sequence of characters:

1234a12a

NOTE:

Function keys cannot be programmed to perform unsetting commands.

To program a Function key:

1)

USER FUNCTIONS:

1) OMIT

From the

User Functions

menu, select

[9]

Miscellaneous

.

2)

Enter the Grand Master code and press .

3)

MISCELLANEOUS:

1) PRINTER CNTRL

Select

[5] Key Custom

.

4)

CHOOSE KEY:

1)

KEY A

The

Choose Key

menu lists the four function keys. Select the function key that you want to program.

5)

PRESS A TO

START/STOP

Press

[A]

(or the function key you selected in step 4).

ProSYS User Guide

53

6)

7)

KEY A CUSTOM

1234a12a

When you have finished entering the series of characters, ensure that the cursor is placed in the field after the last character in the series, and press

[A]

(or the function key you selected in step 4) again. The series of characters is saved and assigned to the selected function key.

For example:

The following series of characters should be entered to program the macro

Fault Reset

:

¾

3#(customer code)#S#¾¾

NOTE:

When entering characters, ensure that the cursor is placed after the last character. Otherwise, the last character you defined and everything after it will be erased, and the Function key will not perform the required function.

8)

Use the numerical keys or the key to enter a series of characters representing your required keys, as described on page

55. Each character you enter is displayed in the second line of the LCD.

If required, select an additional Function key to program and repeat the above procedure.

54

ProSYS User Guide

Using the Set Key to Program Function Keys

In step 4 of the previous procedure, the and the keys are used to toggle between and enter characters that represent keys on the

ProSYS keypad. The following is a list of these characters and the keys they represent:

Character Represents

0-9

A-B

The Numerical keys from 0 to 9.

The Function keys from A to B.

S

The key.

N

The key.

a,b

¾

Group A, Group B

The key.

#

The key.

NOTE:

You can also use the Numerical keys to enter numbers when programming

Function keys. Use the and the keys to move the cursor.

When the character is displayed, press to move the cursor to the next field in the LCD, where you can enter the next character in the series.

When you have finished entering a series of characters, ensure that the cursor is placed in the field after the last character in the series by pressing again.

NOTE:

A macro cannot be used to unset a system.

ProSYS User Guide

55

Chapter 12: Proximity Keypad

The proximity keypad enables you to use a proximity tag to set and unset the security system or to activate and deactivate home appliances and utilities, such as heating and lights.

Proximity tag programming is performed from the

User Functions

menu. When programming a proximity tag, the following three options are available:

Ê

(RE)WRITE TAG:

Ads a new proximity tag (described below).

Ê

DEL BY USER:

Deletes a proximity tag according to the user serial number, as described on page 57.

Ê

DEL BY TAG:

Deletes a proximity tag according to the user tag, as described on page 58.

This section also includes general instructions for using a proximity tag, as described on page 59.

NOTES:

Users can define or delete their individual proximity tags, but the Grand Master can define or delete any user's tag.

Each proximity tag can be assigned to only one user.

Adding a New Proximity Tag

You can add a new proximity tag for each user in the system, as required.

To add a new proximity tag:

1)

USER FUNCTIONS:

1) OMIT

From the

User Functions

[5] Access Code

.

menu, select

2)

Enter your user code and press .

3)

ACCESS CODE:

1) UPDATE CODES

4)

PROX TAG:

1) (RE)WRITE TAG

5)

SELECT USER:

00)0 GRAND

Select

[5] Prox Tag

.

Select

[1] (Re) Write Tag

.

Select the user to which you want to assign the proximity tag and press .

56

ProSYS User Guide

6)

NOTE:

A display of (****) indicates that a user has already been assigned to a specific proximity tag.

USER XX: APPROACH

Within 10 seconds, approach the proximity tag at a distance of 3 to 7 cm from the keypad's keys. The keypad automatically reads the proximity tag and saves it into the system's memory.

Once the proximity tag has been successfully recorded, a long confirmation beep sounds, and a confirmation message is displayed.

If the proximity tag is already stored in the system's memory, the following message is displayed:

USER TAG ALREADY IN

MEMORY

.

NOTES:

Once a proximity tag is recorded, it will be functional from all keypads.

The programmed proximity tag has the same permissions as are defined for the specified user code.

If a user is defined as having the Cleaner security level, then the proximity tag can operate only if a security code was previously defined for that user.

Deleting a Proximity Tag by the User Serial

Number

You can use this option to delete a proximity tag for which the user is known.

To delete a proximity tag by user serial number:

1)

USER FUNCTIONS:

1) OMIT

From the

User Functions

menu, select

[5] Access Code

.

2)

Enter your user code and press .

3)

ACCESS CODE:

1) UPDATE CODES

Select

[5] Prox Tag

.

ProSYS User Guide

57

4)

PROX TAG:

1)

(RE)WRITE TAG

5)

SELECT USER:

00)0 GRAND

Select

[2] Del By User

.

Select the user for which you want to delete the proximity tag and press

.

6)

***DELETE***

ARE YOU SURE? N

Select

[Y]

or

[N]

by using the key and then pressing . If you select

[Y]

, the following confirmation message is displayed:

USER XX: TAG DELETED

.

Deleting a Proximity Tag by the User Tag

You can use this option to delete a proximity tag for which the user is

not

known.

To delete a proximity tag by user tag:

1)

USER FUNCTIONS:

1) OMIT

From the

User Functions

menu, select

[5] Access Code

.

2)

Enter your user code and press .

3)

Select

[5] Prox Tag

.

4)

5)

PROX TAG:

1) (RE)WRITE TAG

APPROACH TAG TO

PROX KEYPAD

Select

[3] Del By Tag

.

Within 10 seconds, approach the proximity tag at a distance of 3 to 7 cm. from the keypad's keys.

If the proximity tag was deleted successfully, the following confirmation message is displayed:

USER TAG XX

DELETED

.

If the system does not recognize the proximity tag, the following message is displayed:

TAG NOT DEFINED IN

MEMORY

.

58

ProSYS User Guide

Using a Proximity Tag

When using a proximity tag, the following points regarding assigned partitions are relevant:

Ê

If your user code is assigned to

only one

partition, then the partition will set or unset automatically.

Ê

If your user code is assigned to

more than one

partition, use the press

or the

.

keys to select the required partition(s) and

To use a proximity tag:

Hold the proximity tag close to the keypad's keys at a distance of approximately 3 to 7 cm.

Based on your user definitions:

The partition(s) assigned to your user code are set/unset. (Ask your engineer for the number of partitions that are assigned to your user code.)

-OR-

The defined device(s) operate(s) (based on its current status).

Note:

To use a proximity tag with the ProSYS Touchscreen Keypad present the tag as follows:

ProSYS User Guide

59

Chapter 13: Complete Menu of User

Functions

Your ProSYS comes with a variety of selectable user functions that become available when you enter the

User Functions

mode. This chapter lists the complete menu of user functions, the most frequently used of which are described in detail in previous chapters of this manual.

To enter the

User Functions

mode, press followed by the

Function

Index

or quick key (see the table below) and your user code. For example, to activate Switch Auxiliary, press

[1-2-3-4]

.

To exit the

User Functions

mode and return to

Normal Operation

mode, press quickly.

Quick

Key

1 Omit

1

Function Description

2

3

Omit Reset Restores any omitted zones.

Omit

Recall

2 Activities

Recalls the most recent omitted zone.

1 Prog.

Output

2

Switch

Auxiliary

Allows user control of previously designated external devices (e.g. an appliance, a motor-driven garage door), as described on page 35.

Interrupts the power supplied to the system's smoke detector(s) for a predetermined interval, thus resetting and "readying" them for subsequent alarms, see page

32.

3

Omit

Zones

Terminate

FM

Provides the ability to omit any of the system's intrusion zones, as described on page 22.

If Follow-Me Phone Number(s) were chosen, their operation can be terminated. Use this function when an alarm has been tripped and there is no need to utilize the Follow-Me phone call. them to perform a remote programming operation on your system.

60

ProSYS User Guide

9

0

01

Quick

Key

Function Description

5 Hand Similar in intent to Initiate Call (above), Hand Over allows your alarm company to call you and, during the call, "hand over" to them the control of your security system.

6 Void Rep

Prg

For engineer use only.

Some protocols have a report code to the ARC for entering and exiting the engineer programming. To avoid the entering report and save time, this function postpones the report for two minutes during which the engineer can enter the programming menu and no report will be made.

8

02

03

04

Enable

U/D destinations as telephone numbers, or Email address

(See page 36)

Each time this function is enabled, your alarm company may subsequently gain a single remote access to your system to make any required programming changes.

Contact your engineer for additional information.

Del Rmt

Msg

Deletes a message that has been sent to the LCD from the Upload/Download software.

More…

Cancel

Report

Sends a "Cancel Alarm" report message to the ARC.

This function is used if the alarm was activated by mistake.

U/D Phone The Grand Master can temporarily change the 3rd

ARC connection. The new number will be valid for 1 hour only. After 1 hour the panel shall revert to the original phone number. When the user is initiating a call to the U/D by using the “INITIATE CALL” user function, the call will use this U/D number.

Enable

Engineer

This function enables the Grand Master to authorize the engineer to access the Engineer programming menu by opening a time window of 1 hour during which he can enter the menu without the Grand

Master authorization.

Engineer

Reset

Enables the engineer to reset an alarm. The option is available only if the user authorized the engineer in location [2][0][3]

ProSYS User Guide

61

Quick

Key

Function Description

05

06

07

Overload

Restore

The Grand Master/Engineer /Sub-engineer/Manager can use this option to restore the Auxiliary power from a power supply, power (If overload condition is still present, disconnect all loads from AUX. Output)

Check

Credit

Use this function to receive information by SMS of the credit level in your Prepaid SIM card. The ProSYS will send SMS Credit Level Request message (User menu: Quick Key [4][0][4][1]) to the provider's phone

(User menu: Quick Key [4][0][4][2]). Once the SMS is received by the provider, the SIM’s credit level is sent back and displayed on the keypad's LCD display or sent to the Follow Me (if defined).

Reset SIM

After charging a prepaid SIM card, the user has to reset the SIM Expire Time manually. The time duration for expiration is defined by your engineer.

3 View

1

Fault

2

3

Alarm

Memory

Partition

Status

Should be used when the system has detected a problem, which is evident by the rapid flashing of the

Ready LED, as described on page 14.

Allows the viewing of the five most recent alarm conditions stored by the system.

Allows the viewing of the partitions' status, the faults in the system and all “not ready” zones.

4

5

6

Zone

Status

Event

Memory

Service

Info

Pressing on the key from the Normal

Operation mode will display the status of the partition to which the keypad is assigned. Pressing the sequence [CODE] from the Normal Operation mode will display the status of all the partitions assigned to the user code.

Allows the display of all system zones and their current status.

Allows the viewing of significant system events including date and time.

Note: The events memory cannot be erased

1) Displays any previously entered service information

2) Displays the system software version.

62

ProSYS User Guide

Quick

Key

Function Description

4 Maintenance

1

2

Indications The indication function allows the Grand Master to perform a test to the following elements in the system:

1) Keypad test (approximately 3 second test):

Momentarily tests the keypad indicators and the system's external sounder(s)

2) Speaker (approximately 10 second test) – Toggle the internal speaker on/off

3) Bell (approximately 20 second test) – Toggles the external bell on/off

4) Strobe (approximately 10 second test) – Toggles the strobe on/off

Battery

Test

Tests the system's standby battery.

3

4

5

6

7

8

9

0

Local

Chime Off

Local

Chime On

Part.

Chime Off

Part.

Chime On

Local

Buzzer Off

Turns OFF a particular keypad's internal sounder for any function involving the Chime feature.

Turns ON a particular keypad's internal sounder for any function involving the Chime feature.

Disables the buzzer for all keypads in the partition for any function involving the Chime feature. The internal speaker will be disabled as well if defined by your engineer.

Enables the buzzer for all keypads in the partition for any function involving the Chime feature. If defined by your engineer, the internal speaker will be enabled as well.

Turns OFF a particular keypad's internal sounder during both Entry and Exit Delay time periods and all fire and intruder alarms.

Local

Buzzer On

Turns ON a particular keypad's internal sounder during both Entry and Exit Delay time periods and all fire and intruder alarms.

Diagnostics

Enables to performs diagnostics tests to: BUS zones, power supply, sounder and GSM/GPRS module.

More

ProSYS User Guide

63

Quick

Key

Function Description

1

2

3

4

Walk Test Enables the engineer or the Grand Master to easily test and evaluate the operation of selected zones in your system

Accessory

Versions

Get ACM

IP

1. Full walk test: The test will display the detected zones and type of detection.

2. Quick walk test: The test will display the undetected zones.

Get the software version of BUS zones, power supply, sounder and GSM/GPRS module.

Prepaid

SIM

View the ACM IP address. Required for establishing remote communication for U/D through the IP network

When using Pre-paid SIM cards, these options are used to receive information regarding the SIM card credit level. For detailed information, refer to the manuals supplied with the GSM/GPRS module.

5 Access Code

1

Update

Codes

2

Authority

Sets, changes, and deletes user codes, as described on page 38.

Links user codes with Authority Levels, as described on page 41.

4

5

User label Assigns labels to users (10 characters long). These labels will be presented in the event log. (GM code

Only)

Prox Tag Assigns user codes to proximity tags, which are used with proximity keypads to set and unset the system, as described on page 56.

6

6 Clocks

Dual Code If defined by your engineer, the system can be configured to be unset only by dual codes, for high security. Up to 16 pairs of codes can be defined. The time between entering the two user codes is 60 seconds. Users with Authority Levels of Cleaner, Set

Only and Guard cannot be used to perform the dual

Code unsetting.

1

2

System

Time

System

Date

Enables the setting of the system time, as described on page 46.

Enables the setting of the system date, as described on page 46.

64

ProSYS User Guide

Quick

Key

Function Description

3

4

5

Next Set Enables automatic Full set of the system at a specific time within the next 24 hours. Next Set operates for one time only since the system deletes the setting activated with.

Next Unset Enables automatic unset of the system at a specific time within the next 24 hours. Next Unset works for one time only since the system deletes the setting after it is acted upon.

Scheduler Enables you to define a weekly program with up to two time intervals per day, during which the system automatically sets, activates POs, or prevents users from unsetting, as described on page 47.

6

Holiday Enables you to define up to 20 holiday periods and the partitions that will be set automatically during the holiday.

7 Engineer Prog

1

Advanced Accesses the full menu of programming options.

2

Selected Accesses a limited menu of programming options for the sub-engineer.

NOTE:

Refer to the ProSYS Installation and Programming Manual for more information about the Engineer Prog functions.

8 Access Control

1

2

3

4

5

6

Settings

Time

Schedule

Group

Access

Record

Users

Defines the door mode for each door and the reader criteria for each reader in the system.

Configures the time schedules by which users can access the system.

Defines access to doors for groups of users during specific time periods.

Adds Set/Unset users and Entry/Exit users to the system.

User

Settings

Defines settings for users, including assigning PIN

(Personal Identification Number) codes, assigning users to specific access groups, and deleting users.

Open Door Remotely opens any door from any keypad that has previously been defined in the system.

ProSYS User Guide

65

3

4

Quick

Key

Function Description

NOTE:

Refer to the Access Control User's Manual for more information about the Access

Control functions.

9 Miscellaneous

1

Printer

Control

(to control on-line printing)

1

2

3

Printer 1 on

Printer 1 off

Printer 2 on

Activates printer 1

Deactivates messages to printer 1

Activates printer 2

4 Printer 2 off Deactivates messages to printer 2

5 systems) are not ready to Set after an alarm or tamper condition. To restore the system to Normal

Operation mode, an Engineer code or Anti-code must be entered. Entering the code supplied by the technician at this location will restore the system to the Normal Operation mode. (Refer to page 29)

Deactivates a latched PO that has been activated as a result of a duress code being entered.

Duress

Restore

Voice Msg Customizes the spoken messages that are announced when the user accesses the system from a remote telephone. Refer to the Voice Module

Programming and Operations Manual for more information.

Key

Custom

Records a series of commands and assigns them to a function key. For detailed information refer to page

53.

66

ProSYS User Guide

Appendix A: System Faults

The following table lists few possible fault conditions that might appear in the system. For other faults messages that might appear on your

LCD display please refer to your engineer.

Fault Description Response

Low Battery

AC FAULT

AUXLIARY FAULT

The capacity of the battery is low or missing and needs to be recharged or replaced.

Low battery fault can be from the main panel or from power supply expander.

The mains (AC) power has been interrupted; the system will continue to operate on its standby battery as long as possible.

This fault can appear from the main or from power supply expander.

The panel's auxiliary power, used to supply electric current to designated devices (e.g. motion detectors, keypads, and smoke detectors), has failed.

Contact your engineer.

Check the connection of the panel's transformer to its AC source.

Verify that power has not been interrupted or switched off.

Contact your engineer.

FALSE CODE P=X

If enabled by your engineer, your system will report a false code as a fault.

Once the fault has been displayed

(LCD keypad only), it will automatically be removed from the system.

LINE FAULT

The telephone line used for

ARC/Follow Me communication is either disconnected or inoperative.

If all premises' telephones are operating properly, contact your engineer. If not, contact your local telephone company.

ProSYS User Guide

67

Fault Description Response

COMM FAULT

A fault has been detected in the wiring supporting system peripherals. The fault messageindicates the device with that causes the fault

Contact your engineer.

SYSTEM CLOCK

Define the system's time and date.

TAMPER

BELL FAULT

The system's clock has lost track of the time and/or date.

A sabotage attempt has been detected in a perepheril device of box.

A fault has been detected in a bell connected to the main panel or to a power supply expander.

Contact your engineer

Contact your engineer.

68

ProSYS User Guide

Appendix B: System Sounds

In addition to the visual indications provided by your keypad(s), your system is designed to produce audible annunciation after certain events. Depending on the circumstances, such sounds may be made by your system's keypad(s) or its sounders (e.g. a siren or bell).

NOTE:

If defined by your engineer, the internal bell can follow any of the keypad sounds.

Event Keypad

Sound/

Internal

Bell

Intruder Alarm

Rapid beeping Rapid beeping

Fire Alarm

Keypad Police

Emergency

Keypad Medical

/Special

Setting/Unsetting

Rapid beeping

No Sound (1)

No sound

Rapid beeping

No Sound (1)

No sound

No sound Systm is set: 1 chirp

System Unset:

2 chirp (Keyfob)

Unset after alarm: 4 chirps

(Keyfob)

Three rapid beeps No sound

Entering an Incorrect

Code

Entry Delay

Countdown

Slowly repeating tones every 2 seconds until the

Entry Delay time period expires (2)

No sound

Exit Delay

Countdown

Continuous tone during Exit Delay time period (2)

No Sound

Open zone during

Exit Delay (Out of

Exit route)

Correct/Incorrect

Data

3 short beeps every 2 seconds

A one-second tone if completed correctly; three rapid error beeps if incorrect

No Sound

No Sound

External

Bell

Rapid beeping

Yes (staggered)

No Sound (1)

No sound

Systm is set: 1 chirp

No sound

No sound

No Sound

No Sound

No Sound

ProSYS User Guide

69

Bell Circuit Failure or

Fire Loop Fault or

Line Fault

Chime Sound

Three rapid beeps at 10-second intervals (2,3)

2 second buzzer beep (4)

No Sound No Sound

NOTES:

1. Based on decisions made at the time your alarm system was installed this sound may be enabled or disabled

2. Keypad beeps may be disabled at the user's discretion, see buzzer On/Off on page 63.

3. Press for two seconds to stop the fault beeps.

4.

Any intrusion zone, if selected for the Chime feature, will, when violated during the unset period, cause the keypad to annunciate the event. The chime can also be disabled when not required.

70

ProSYS User Guide

Appendix C: Scheduling Tables

Use the following table to define each of the weekly programs.

Schedule Program

No:__________

Program Name:

______________

Program Type Parameter Definitions

Set / Unset

†

Partition

Set Mode:

†

Full Set

†

Part Set

†

Group Set

1 2 3 4 5 6 7 8

† † † † † † † †

Select Group:

†

A

†

B

Prog. Output

†

1st PO No: _________ 3rd PO No:_________

2nd PO No:_________ 4th PO No:_________

NOTE:

For the PO weekly program, you can define a separate time definition during holiday.

User Unset

Limitation

†

Day

User # Name User # Name

NOTE:

You can choose any user in the system.

Start Time

1 HH:MM

Stop Time 1

HH:MM

Start Time 2

HH:MM

Stop Time 2

HH:MM

Sunday

Monday

Tuesday

Wednesday

Thursday

Friday

Saturday

ProSYS User Guide

71

Appendix D: Terms and Definitions

Alarm Receiving Centre (ARC):

Your system is set up to report alarms to an ARC, which is a facility that continually monitors the activities of many security systems (usually via the telephone network) and dispatches the proper authorities.

Authority Level:

Each individual using the system is assigned a user code, which, in turn, is linked to an Authority Level. Users with a "higher authority" have access to a greater number of system functions, while those with a "lower authority" are more restricted in what they may do.

There are nine different Authority Levels available for users of the

ProSYS, as described on page 41.

Chime:

The chime is a series of three short keypad tones, which can be set up to annunciate, during the unset period, the violation of selected intrusion zone(s). For example, the chime tone can be used to annunciate the arrival of a customer each time the front door opens.

The chime can be disabled or enabled at your discretion.

Event Memory:

A list of system events can be displayed on an LCD keypad or uploaded to the alarm company via the Upload/Download software and printed for further analysis.

Exit/Entry Route:

Your security system must incorporate an entry/exit route to allow proper entry and exit to and from the premises without causing inadvertent alarms.

Exit/Entry Delay:

Your security system must incorporate an entry/exit delay to allow proper entry and exit to and from the premises without causing inadvertent alarms.

Exit Terminator:

A push button normally mounted outside the premises that is used to set the system.

Fault Reporting:

If required, your security system may also report to the ARC any faults or malfunctions it senses, so that a service call can be made.

Final Exit:

The last door or detector operated by the user on the exit route.

Follow-Me Report:

In addition to the standard event reporting to the

ARC, the system can send Event messages to a designated system user's telephone or Email.

Group:

A number of zones gathered as one unit to allow partial setting.

Each zone can be assigned to any one (or a combination) of two groups (A, B). Each partition can be divided into a maximum of two groups.

72

ProSYS User Guide

Keyswitch:

Your system may also be equipped with a keyswitch, which is useful for simple setting and unsetting operations (usually at a remote location).

Partition:

One of the advantages of ProSYS is its ability to divide any system into a number of partitions. You can think of each partition as a separate security system that can be set and unset individually.

Programmable Output (PO):

A household appliance.

In addition to your system's normal operation, it is possible to place a household appliance or premises lighting under the control of the ProSYS, enabling it to be turned on and off automatically, or by user command from any system keypad.

Proximity:

A technology that enables a keypad to sense when a proximity key tag is near it. This provides an easy and user-friendly way to set or unset the security system.

Scheduler:

The system's built-in clock enables scheduling of automatic operations, such as Setting and Unsetting, Output activation, and user limitation.

Tamper:

A device that prevents system hardware from being tampered with by triggering an alarm whenever a hardware component is opened.

Upload/Download:

Software used by the engineer for programming the ProSYS and by the user for operating the system and viewing system status.

User Code:

A four-digit or six-digit code that is used to perform many of the ProSYS functions.

Zone:

A single detector, or collection of detectors, usually relating to a certain area of the premises or type of protection. Zones that use devices designed to detect break-ins are called intruder zones. Another kind of zone may contain one or more smoke detectors

.

Such zones are called fire zones. An environmental zone typically protects the premises from gas leaks and/or flooding.

ProSYS User Guide

73

Notes

74

ProSYS User Guide

RISCO Group Limited Warranty

RISCO Group and its subsidiaries and affiliates ("Seller") warrant its products to be free from defects in materials and workmanship under normal use for 24 months from the date of production. Because Seller does not install or connect the product and because the product may be used in conjunction with products not manufactured by the Seller, Seller cannot guarantee the performance of the security system which uses this product.

Seller’s obligation and liability under this warranty is expressly limited to repairing and replacing, at Sellers option, within a reasonable time after the date of delivery, any product not meeting the specifications. Seller makes no other warranty, expressed or implied, and makes no warranty of merchantability or of fitness for any particular purpose.

In no case shall seller be liable for any consequential or incidental damages for breach of this or any other warranty, expressed or implied, or upon any other basis of liability whatsoever.

Seller’s obligation under this warranty shall not include any transportation charges or costs of installation or any liability for direct, indirect, or consequential damages or delay.

Seller does not represent that its product may not be compromised or circumvented; that the product will prevent any persona; injury or property loss by burglary, robbery, fire or otherwise; or that the product will in all cases provide adequate warning or protection. Buyer understands that a properly installed and maintained alarm may only reduce the risk of burglary, robbery or fire without warning, but is not insurance or a guaranty that such will not occur or that there will be no personal injury or property loss as a result.

Consequently, seller shall have no liability for any personal injury, property damage or loss based on a claim that the product fails to give warning.

However, if seller is held liable, whether directly or indirectly, for any loss or damage arising from under this limited warranty or otherwise, regardless of cause or origin, sellers maximum liability shall not exceed the purchase price of the product, which shall be complete and exclusive remedy against seller.

No employee or representative of Seller is authorized to change this warranty in any way or grant any other warranty.

WARNING

: This product should be tested at least once a week.

ProSYS User Guide

75

Contacting RISCO Group

RISCO Group is committed to customer service and product support. You can contact us through our website www.riscogroup.com or as follows:

United Kingdom

Tel: +44-161-655-5500 [email protected]

Italy

Tel: +39-02-66590054 [email protected]

Spain

Tel: +34-91-490-2133 [email protected]

France

Tel: +33-164-73-28-50 [email protected]

USA

Tel: +1-631-719-4400 [email protected]

Brazil

Tel: +1-866-969-5111 [email protected]

China

Tel: +86-21-52-39-0066 [email protected]

Poland

Tel: +48-22-500-28-40 [email protected]

Belgium

Tel: +32-2522-7622 [email protected]

Israel

Tel: +972-3-963-7777 [email protected]

All rights reserved.

No part of this document may be reproduced in any form without prior written permission from the publisher.

© RISCO Group 10/09 5IN128UMUK E