User Guide
TABLE OF CONTENTS
Professional Intelligent Follow Spot
1. Safety Instruction
2. Technical Specification
2.1 Inserting/Exchanging Rotating Gobos
2.2 Beam Angle
3. Lamp
4. How To Set The Unit
4.1
4.2
4.3
Control Panel
Main Function
Home Position Adjust
5. How To Control The Unit
5.1 Universal DMX Controller
5.2 Dedicated Controller
5.3 DMX 512 Configuration
5.4 DMX 512 Connection
6. Troubleshooting
7. Fixture Cleaning
User Guide
Professional Entertainment Technology
1F
• Warning
1. Safety Instruction
♦
Please read the instruction carefully which includes important
To prevent or reduce the risk of electrical shock or fire, do not expose the unit to rain or
moisture.
♦
Never touch bulb with bare fingers as it is very hot after using.
WARNING
♦
Hot lamp explosion hazard. Do not open the unit within five minutes after switching off.
♦
Please keep this User Guide for future consultation. If you sell the unit to another user,
♦
Do not start on the unit without bulb enclosure or housing are damaged.
be sure that they also receive this user guide.
♦
The housing, the lenses, or the ultraviolet filter must be replaced if they are visibly
information about installation, operation and maintenance.
♦
♦
damaged.
Unpack and check carefully there is no transportation damage before using the unit.
Before operating, ensure that the voltage and frequency of power supply match the
♦
Do not look directly at the light while the bulb is on.
power requirements of the unit.
♦
It’s important to ground the yellow/green conductor to earth in order to avoid electric
• Caution
shock.
There are no user serviceable parts inside the unit. Do not open the housing or attempt any
♦
The unit is for indoor use only and only in a dry location.
repairs by yourself. If you need any service, please contact your nearest dealer.
♦
The unit must be installed in a location with adequate ventilation, at least 50 cm from
adjacent surfaces. Be sure that no ventilation slots are blocked.
• Installation
♦
Disconnect main power before fuse/lamp replacement or servicing.
The unit should be mounted via its mounting system (as show below). Always ensure that
♦
Replace fuse/lamp only with the same type. Do not use any other type of lamp.
the unit is firmly fixed to avoid vibration and slipping while operating. Always ensure that the
♦
Make sure there are no flammable materials close to the unit while operating as it is
structure to which you are attaching the unit is secure and is able to support a weight of 80
fire hazard.
kgs for each unit.
♦
Use safety cable when fixes this unit. Don’t handle the unit by taking its head only, but
always by taking its base.
♦
Maximum ambient temperature is TA: 40℃. Don’t operate it where the temperature is
higher than this.
♦
Unit surface temperature may reach up to 85℃. Don’t touch the housing bare-hand
during its operation. Turn off the power and allow about 15 minutes for the unit to cool
down before replacing bulb or serving as the unit could be very hot.
♦
In the event of serious operating problem, stop using the unit immediately. Never try to
repair the unit by yourself. Repairs carried out by unskilled people can lead to damage
or malfunction. Please contact the nearest authorized technical assistance center.
Always use the same type spare parts.
♦
Don’t connect the device to any dimmer pack or power pack.
♦
Do not touch any wire during operation as high voltage might be causing electric
shock.
2F
3F
2. Technical Specification
3. Lamp
Power supply
-AC 230V 50/60Hz
In case of replacement of the lamp or maintenance, do not open the
-AC 100V 50/60Hz / 120V 60Hz (Only for IF-575 version)
fixture within 15 minutes until the unit cools down after switching off.
Lamp
- MSI 1200W/S / HMI 1200/S K SFc10-4
Because of its high internal pressure, there might be a risk that the Discharge lamp
- HMI 575W & HTI 575W (Osram)or HMQ 575 & HMQ 575/2 (Xenpow)
Optical system
- High efficiency optical system
would explode during operation. The lamp emits intense UV radiation which is harmful
to the eyes and skin. The high luminance of the arc can cause severe damage to the
- High quality optical lens and dichroic colors
retina if looks directly at the lamp.
MSI 1200W/S / HMI 1200/S K SFc10-4
- Beam angle: 13°
IF-575:
Shutter/Dimmer
HMI 575W & HTI 575W (Osram)or HMQ 575 & HMQ 575/2 (Xenpow)
- Blackout, 0~100% smooth dimming and strobe speed variable (1~12 flashes per
second)
1. Always switch off the main supply and never handle the lamp or luminant when it is
Movement
- Pan: 360°
Color Wheel
hot.
Tilt: 90°
2. Do not touch the bulb with bare hands. If this happens, clean the lamp with denatured
alcohol and wipe it with a lint free cloth before installation.
- 8 dichroic colors plus white color
3. The lamp generates UV radiation. Never operate the lamp without appropriate shielding.
- Rainbow effect at variable speeds
4. When burning, the lamp operates at high pressure and there is a slight risk of arc tube
Color Temperature
- Standard 6000K, adjustable 5600K and 3200K
rupture. The risk increases with age, temperature and improper handling of the lamp. Do
not use the lamp any longer than its specified life.
DMX Channels
- Standard DMX512 signal addressing and controlled by any universal DMX controller
5. Make sure the lamp is located in the center of the reflector for the best spot.
Channel 1 = Shutter
Channel 2 = Iris
Channel 3 = Color
Channel 4 = Color temperature
Channel 5 = Dimmer
Channel 6 = Focus
Luminous intensity: (HMI 1200W)
4F
5F
6. If changing the lamp, remove old lamp from lamp socket. Hold the new lamp only by its
4. How To Set The Unit
ceramic base. Never touch the glass bulb. Insert the new lamp in the lamp socket.
7. Please turn the head in horizontal position. Hinge must be on the upper side of the head.
4.1 Control Panel
Turn screws left and remove plastic cover. Loosen head screw and open the lamp cover
8. With the nipple of the lamp facing the back insert one end of the lamp into the socket. Pull
up the spring of the other side of the socket and snap the other end of the lamp into place.
Make sure it fits correctly into the socket. Please refer to the diagram to know how to put
the lamp in correct position.
Display
To show the various menu and to select functions.
Button
MENU
To select the programming functions
DOWN
To go backward in the selected functions
UP
To go forward in the selected functions
ENTER
To confirm the selected functions
On/Off
Turns On/Off the power
Fuse
To replace the fuse
Power
To connect the power plug
DMX input/output
For DMX 512 link, use 5-pin XLR plug cable to link the unit together
6F
7F
4.2 Main Function
To select any of the given functions, press the MENU button up to when the required one is
showing on the display. Select the function by ENTER button and the display will blink. Use
DOWN and UP button to change the mode. Once the required mode has been selected,
press the ENTER button to setup or it will automatically return to the main functions without
any change after idling 8 seconds. To go back to the functions without any change press the
MENU button. The main functions are showing below:
DMX512 Address Setting
Press the MENU button until the
is blinking on the display. Pressing ENTER button
and all channels of the unit will return to their standard position. To go back to the functions
press the MENU button again.
4.3 Home Position Adjust
Press MENU button for at least 5 seconds into offset mode to adjust the home position,
when you want to adjust gobo and color home position, you should be run
Self-Test
MENU
Reset
mode
first , the functions are shown below:
Fixture Hours
Lamp on
Lamp off
Reset
DMX 512 Address Setting
Press the MENU button until the
is showing on the display. Pressing ENTER
button and the display will blink. Use DOWN and UP button to change the DMX512 address.
Once the address has been selected, press the ENTER button to setup or automatically
return to the main functions without any change after 8 seconds. To go back to the functions
without any change press the MENU button again.
is blinking on the display. Pressing ENTER
button and the unit will run self-test by built in program. To go back to the functions press the
MENU button again.
up to when the
is shown on the display. Pressing ENTER button and the display
will blink. Use DOWN and UP button to adjust the color home position. Once the color has
been selected, press the ENTER button to setup or automatically return to the offset
functions without any change press the MENU button again, To go back to the main
Effect offset
Press the MENU button for at least 5 seconds into offset mode, use DOWN and UP button
up to when the
is shown on the display. Pressing ENTER button and the display
will blink. Use DOWN and UP button to adjust the effect home position. Once the effect has
Fixture Hours
Press the MENU button until the
Press the MENU button for at least 5 seconds into offset mode, use DOWN and UP button
functions without any change after 8 seconds.
Self-Test
Press the MENU button until the
Color offset
is blinking on the display. Pressing ENTER button
and the display will show the number of working hours of the unit. To go back to the
functions press the MENU button again.
8F
been selected, press the ENTER button to setup or automatically return to the offset
functions without any change press the MENU button again, To go back to the main
functions without any change after 8 seconds.
9F
5.2 Dedicated Controller
Dimmer offset
Press the MENU button for at least 5 seconds into offset mode, use DOWN and UP button
IF-series has 6 channels for international protocol DMX512. It can finish all operations via
is shown on the display. Pressing ENTER button and the display will
dedicated controller without using other controllers. When the power is switched on, the
up to when the
blink. Use DOWN and UP button to adjust the dimmer home position. Once the effect has
projector automatically starts to run the self-test. After finishing these, the fixture is ready for
been selected, press the ENTER button to setup or automatically return to the offset
operation.
functions without any change press the MENU button again, To go back to the main
functions without any change after 8 seconds.
5. How To Control The Unit
Two ways to operate:
1. By universal DMX controller
2. By dedicated controller
No need to turn the unit off when you change the DMX address, as new DMX address
setting will be effected at once. Every time you turn the unit on, it will show 1200 on the
display and move all the motors to their ‘home’ position and you may hear some noises for
about 20 seconds. After that the unit will be ready to receive DMX signal.
1. DIMMER OPEN buttons: Holding the buttons, the light beam will become more stronger
and stronger, then shutter will obtain max. value. After un-holding it, the light beam and
5.1 DMX Controller
If you use a universal DMX controller to control the units, you have to set DMX address from
shutter resumes its initial condition. There are 2 buttons on the both sides of the controller
1 to 512 channels so that the units can receive DMX signal.
for your convenient operation.
Press the MENU button up to when the
is shown on the display. Pressing ENTER
2. IRIS OPEN buttons: Holding the buttons, the light iris will become more bigger and
button and the display will blink. Use DOWN and UP button to change the DMX512 address.
bigger. After un-holding it, the light beam resumes its initial condition. There are 2 buttons
Once the address has been selected, press and keep ENTER button pressed up to when
on the both sides of the controller for your convenient operation.
the display stops blinking or storing automatically 8 seconds later. To go back to the
3. FIXED COLOURS & RAINBOW switch: Turning the switch on the RAINBOW position,
functions without any change press the MENU button again.
enable the rainbow function, you can set different rainbow speed by pressing COLOUR
Please refer to the following diagram to address your DMX512 channel for the first 4 units.
buttons from slow to fast. Turning the switch on the FIXED COLOURS position, enable
6 Channels:
the fixed colors function and disable the rainbow function. They will save last setting
automatically in each step.
4. COLOUR buttons: There are 9 color buttons of white, red, yellow, magenta, green,
orange, blue, pink and purple. Select the light beam colors by pressing the relative color
buttons.
5. COLOUR TEMPERATURE switch: Adjusting this switch to obtain 3 kinds of color
temperature: Standard 6000K, 5600K and 3200K.
10F
11F
6. DIMMER slider: Adjusting the slider from 0% to 100% position, the light beam will
become more stronger and stronger till the dimmer reach 100%.
5.4 DMX512 Connection
The DMX512 is widely used in intelligent lighting control, with a maximum of 512 channels.
7. SHUTTER slider: Adjusting the slider from slow to fast position, the strobe speed will
become from slow to fast.
8. IRIS slider: Adjusting the slider from min. to max. position, the light beam size will
become more bigger and bigger till the iris opened fully.
9. FOCUS slider: Adjusting the suitable focus by pushing this slider from left to right.
65. 3 DMX512 Configuration
1. If you using a controller with 5 pins DMX output, you need to use a 5 to 3 pin
adapter-cable.
2. At last unit, the DMX cable has to be terminated with a terminator. Solder a 120 ohm
1/4W resistor between pin 2(DMX-) and pin 3(DMX+) into a 3-pin XLR-plug and plug it in
the DMX-output of the last unit.
3. Connect the unit together in a `daisy chain` by XLR plug from the output of the unit to the
input of the next unit. The cable can not branched or split to a `Y` cable. DMX512 is a
very high-speed signal. Inadequate or damaged cables, soldered joints or corroded
connectors can easily distort the signal and shut down the system.
4. The DMX signal is able to pass through each fixture continuously, so if one fixture in the
chain is out of order, all the fixtures after this point will not be affected.
5. Each lighting unit needs to have an address set to receive the data sent by the controller.
The address number is between 0-511 (usually 0 & 1 are equal to 1).
6. The end of the DMX512 system should be terminated to reduce signal errors.
7. 3 pin XLR connectors are more popular than 5 pin XLR.
3 pin XLR: Pin 1: GND, Pin 2: Negative signal (-), Pin 3: Positive signal (+)
5 pin XLR: Pin 1: GND, Pin 2: Negative signal (-), Pin 3: Positive signal (+)
12F
13F
6. Troubleshooting
7. Fixture Cleaning
Following are a few common problems that may occur during operation. Here are
The cleaning of internal and external optical lenses and/or mirrors must be carried out
some suggestions for easy troubleshooting:
periodically to optimize light output. Cleaning frequency depends on the environment in
which the fixture operates: damp, smoky or particularly dirty surrounding can cause greater
A. The unit does not work, no light and the fan does not work
accumulation of dirt on the unit’s optics.
1. Check the connect power and main fuse.
Clean with soft cloth using normal glass cleaning fluid.
2. Measure the mains voltage on the main connector.
Always dry the parts carefully.
3. Check the power on LED.
Clean the external optics at least every 20 days. Clean the internal optics at least every
30/60 days.
B. Not responding to DMX controller
1. Check the address settings and DMX polarity.
2. If you have intermittent DMX signal problems, check the pins on connectors or on PCB
of the unit or the previous one.
EC- Declaration of Conformity
3. Try to use another DMX controller.
We declare that our products (lighting equipments) comply with the following
4. Check in the DMX cables run near or run alongside to high voltage cables that may
specification and bears CE mark in accordance with the provision of the
cause damage or interference to DMX interface circuit.
Electromagnetic Compatibility (EMC) Directive 89/336/EEC.
C. One of the channels is not working well
1. The stepper motor might be damaged or the cable connected to the PCB is broken.
EN55014-2: 1997 A1:2001, EN61000-4-2: 1995; EN61000-4-3:2002;
2. The motor’s drive IC on the PCB might be out of condition.
EN61000-4-4: 1995; EN61000-4-5: 1995, EN61000-4-6:1996,
D. The lamp is cutting out intermittently
EN61000-4-11: 1994.
1. The lamp is not working well. Check the main voltage either too high or too low.
2. Internal temperature may be too high. Check and if necessary replace the fan.
&
Harmonized Standard
EN 60598-1: 2004
IEC 60598-1:2003+ corrigendum 2004
Part 1:General requirements and test
Following the provisions of the low voltage directive 73/23/EEC and 93/68/EEC
14F
15F
Technical Specifications
Power
Fuse
Lamp
Dimension
Weight
AC 230V~50/60Hz
AC 100V~50/60Hz or 120V~60Hz (only for HMI 575W version)
6 x 30 mm Glass T15A (HMI-1200W version)
6 x 30 mm Glass T10A (HMI 575W version)
MSI 1200W/S / HMI 1200/S K SFc10-4/ HMI 575W
1170 x 330 x 225 mm
405 x 360 x 35 mm (Controller)
42.4 kg (HMI-1200W version)
38 kg (HMI 575W version)
Innovation, Quality, Performance.