Elkay LK4590 Outdoor Stone Fountain Pedestal Non-Filtered Installation Instructions
Advertisement
Advertisement
LK4590_FTN 4590_FTN
Owners Manual
Model 4590
Floor Mount Barrier Free Stone Fountain
INSTALLER
4590 Fountains are among the easiest to install Fountains on the market today. To assure you install these models easily and correctly,
PLEASE READ THESE SIMPLE INSTRUCTIONS BEFORE STARTING THE
INSTALLATION. CHECK YOUR INSTALLATION FOR COMPLIANCE WITH
PLUMBING, ELECTRICAL, AND OTHER APPLICABLE CODES. After installation, leave these instructions with the Fountain for future reference.
IMPORTANT
ALL SERVICE TO BE PERFORMED BY AN AUTHORIZED SERVICE PERSON
IMPORTANT! INSTALLER PLEASE NOTE.
THE GROUNDING OF ELECTRICAL EQUIPMENT SUCH AS TELEPHONE, COMPUTERS, ETC. TO
WATER LINES IS A COMMON PROCEDURE. THIS GROUNDING MAY BE IN THE BUILDING OR MAY
OCCUR AWAY FROM THE BUILDING. THIS GROUNDING CAN CAUSE ELECTRICAL FEEDBACK
INTO A FOUNTAIN, CREATING AN ELECTROLYSIS WHICH CAUSES A METALLIC TASTE OR AN
INCREASE IN THE METAL CONTENT OF THE WATER. THIS CONDITION IS AVOIDABLE BY USING
THE PROPER MATERIALS AS INDICATED. ANY DRAIN FITTINGS PROVIDED BY THE INSTALLER
SHOULD BE MADE OF PLASTIC TO ELECTRICALLY ISOLATE THE FOUNTAIN FROM THE BUILDING
PLUMBING SYSTEM.
1. Water supply 3/8" O.D. unplated copper tube. Waste 1-1/4" IPS. Contractor to supply waste trap and service stop valve in accordance with local
code.
2. Connecting lines to be made of unplated copper and should be thoroughly flushed to remove all foreign matter before being connected to
fountain. This fountain is manufactured in such a manner that it does not in any way cause taste, odor, color, or sediment problems.
3. Connect fountain to supply line with a shut-off valve and install a 3/8" unplated copper water line between the valve and the cooler. Remove any
burrs from outside of water line. Push the tubes straight into the fittings until they reach a positive stop, approximately 3/4" (see Fig. 2). DO NOT
SOLDER TUBES INSERTED INTO THE STRAINER AS DAMAGE TO THE O-RINGS MAY RESULT.
4. These products are designed to operate on 20 psig to 105 psig supply line pressure. If inlet pressure is above 105 psig, a pressure regulator must
be installed in the supply line. Any damage caused by reason of connecting this product to supply line pressures lower than 20 psig or higher
than 105 psig is not covered by warranty.
Page 1 96627C (Rev. SID - 1/11)
LK4590_FTN 4590_FTN
ROUGH-IN DRAWING
START UP
1. This fountain is to be mounted on a smooth, flat, finished
surface with adequate support structure.
NOTE: Mounting structure must be capable of
supporting 300 lb. load on fountain.
2. Refer to rough-in for plumbing.
3. Install shut-off valve on water supply. (valve not furnished)
4. Locate and install fountain using 3/8" minimum screws or
bolts. (Screws or bolts not furnished)
CAUTION: This fountain is rated for inlet water pres
sure of 20-105 PSI. A pressure reducing regulator
should be used if the inlet water supply exceeds
105PSI.
5. Connect water supply and fountain drain. Water connection
and drain must comply with local codes.
6. Turn on water supply and check all connections for leaks.
1/4" O.D. TUBE
WATER INLET
TO COOLER
FIG. 1
FIG. 2
96627C (Rev. SID - 1/11) Page 2
3/8" O.D. UNPLATED
COPPER TUBE CONNECT
COLD WATER SUPPLY
BUILDING WATER INLET
NOTE: WATER FLOW
DIRECTION
SERVICE STOP
(NOT FURNISHED)
6
9-B, 14
ITEM NO.
16
17
18
19
N/S
N/S
11
12
13
14
15
7
8
9A
9B
10
1
2
3
4
5
6
LK4590_FTN 4590_FTN
ITEMIZED PARTS LIST
PART NO.
100147140560
100322740560
101570540560
15005C
15013C
170705042830
40048C
40089C
400942308640
98287C
40169C
45845C
50986C
75589C
110544942550
56121C
600985551640
61313C
70683C
75588C
55996C
56092C
DESCRIPTION
Drain Gasket
Bubbler Gasket
Drain Gasket
Regulator Retaining Nut
Bubbler Tube Assy.
Basin
Button
Cover Nut
Bubbler
Bubbler
Hex Nut 1-5/16 -20UN
Drain Tube
Regulator Holder
Gasket
Set Screw #8-32 x .125"
Drain Elbow
Drain Plug Assy.
Regulator
Union - 1/4"
Slip Joint Nut 1-1/4"
In-Line Strainer
Poly Tubing (Cut To Length)
9-A, 14
2
2
5
18
3
16
See
Fig. 3
1
15
13 19 11
8 7 4 17 10 12
Fig. 3
Page 3 96627C (Rev. SID - 1/11)
LK4590_FTN 4590_FTN
STREAM HEIGHT ADJUSTMENT: Stream height is factory set at
35 PSI. If supply pressure varies greatly from this, remove items
7 & 8 (See Fig. 3) and adjust screw on item 17. Clockwise adjustment will raise stream and counter-clockwise adjustment will lower stream. For best adjustment, stream should hit basin approx. 6-1/2" from bubbler.
Fig. 4
TROUBLE SHOOTING AND MAINTENANCE
Orifice Assy: Mineral deposits on orifice can cause water flow to spurt or not regulate.
Mineral deposits may be removed from the orifice with a small round file or
small diameter wire. CAUTION: DO NOT file or cut orifice material.
Stream Regulator: If orifice is clean, regulate flow as in “STREAM HEIGHT ADJUSTMENT”
instructions on page 4. If replacement is necessary, see parts list for correct regulator
part number.
Actuation of Quick Connect Water Fittings: Fountain is provided with lead-free connectors
which utilize an o-ring water seal. To remove tubing from the fitting, relieve
water pressure, push in on the gray collar while pulling on the tubing. (See Fig.2)
To insert tubing, push tube straight into fitting until it reaches a positive stop,
approximately 3/4".
PRINTED IN U.S.A.
96627C (Rev. SID - 1/11)
FOR PARTS, CONTACT YOUR LOCAL DISTRIBUTOR OR CALL 1.800.323.0620