Admiral Craft BB 48G, BB 60G, BB 72G Back Bar Coolers Uživatelská příručka

Admiral Craft BB 48G, BB 60G, BB 72G Back Bar Coolers Uživatelská příručka

Admiral Craft BB-72G is a bar cooler with glass swing door designed to keep your drinks cold. It has a temperature control setting that allows you to set the approximate temperature to 35°F. The unit has an interior light for easy visibility and adjustable shelves for customization. The BB-72G is designed for indoor use and should be placed in a well-ventilated area with at least 1 inch of space between the wall and the rear of the unit. It should be plugged into a dedicated 3-prong grounded outlet and should not be used with an extension cord.

advertisement

Assistant Bot

Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.

Admiral Craft BB-48G, BB-60G, BB-72G Owner's Manual | Manualzz

BB-48G, BB-60G, BB-72G

Back Bar Coolers – Glass Swing Door

This manual contains important information regarding your

Admiral Craft unit. Please read this manual thoroughly prior to equipment set-up, operation and maintenance. Failure to comply with regular maintenance guidelines outlined in this manual may

void the warranty. MUST READ!!!

WARNINGS

• Do not immerse unit, cord or plug in liquid at any time

• Plug only into a 3-hole grounded electrical outlet

• Do not use this unit for anything other than intended use

• Do not use outdoors

• Do not use if unit has a damaged cord or plug, in the event the appliance malfunctions, or has been damaged in any manner

• Keep children and animals away from unit

• Any incorrect installation, alterations, adjustments and/or improper maintenance can lead to property loss and injury

All repairs should be done by authorized professionals only

• Ensure that the designated power supply is adequate for continual usage and the voltage is correct

• If power shuts off, wait 5 minutes before turning the unit back on to avoid damage to the compressor

INSTALLATION

1. To remove the unit from the wood skid, using a Phillips head screwdriver, un-screw the 4 screws from the L-bracket

2. Remove skid by unscrewing all base rail anchor brackets.

3. Lift unit off skid. Please remember not to use the countertop as a lifting point. Also remember to leave the cabinet upright for 24 hours before plugging into power source.

4. Place unit in desired location. Make sure there is adequate ventilation. If necessary use an exhaust fan to keep cool.

Improper installation will void the manufacturer’s warranty.

5. Make sure unit is in a level area.

6. When setting unit in desired location make sure it is near a 3-prong grounded wall outlet that is set for the proper voltage requirements. Compressor warranties are voided if compressor burns out due to inadequate power

supply.

7. Do not use an extension cord.

8. Unit should always be plugged into its own dedicated circuit.

It is strongly recommended that any servicing be performed by a manufacture’s authorized service technician.

For proper installation, cabinet must be fastened to the floor with one of the following approved NSF sealants:

Minnesota Mining #ECU800 Caulk

Minnesota Mining #ECU2185 Caulk

Minnesota Mining #ECU1055 Bead

Minnesota Mining #ECU1202 Bead

Armstrong Cork – Rubber Caulk

Products Research Co #5000 Rubber Caulk

GE Silicone Sealer

Dow Corning Silicone Sealer

1. Position cabinet on level surface and allow at least 1 inch between the wall and rear of the unit for proper ventilation.

2. Using a carpenter’s level, make sure the unit is level side to side and front to back and cabinet interior floor.

3. To apply the sealant: a. Draw an outline on the base of the floor b. Raise and place blocks under the front side of the cabinet c. Apply the NSF approved bead sealant (see list above) to the floor half an inch inside the outline drawn d. Raise and place blocks under the rear of the cabinet and repeat steps a-c e. Once cabinet is on floor in place, check to make sure the seal is around the entire unit and is tight

Note: When sealing unit on asphalt floor, place a layer of tape on the floor prior to applying the sealant to protect the floor.

TO USE

1. Plug the power cord into proper outlet and the compressor will turn on.

2. Set the unit to temperature control setting #4 to give the approximate temperature of 35°F. Allow unit to cool down for a couple of hours before re-adjusting the control setting.

Excessive adjusting of the temperature control switch is not advised.

To ensure proper air flow inside the cooler, load products so that they don’t press against the back wall or comes within 4 inches of the evaporator housing. Cold air off the coils must circulate down the back wall.

3. To turn on interior lights, open the front door and the switch is located towards the right of the unit.

Note: If the unit is disconnected or shut off, wait 5 minutes before re-starting unit.

CLEANING

Condenser

• Condensers naturally accumulate dust and require cleaning every 30 days. Dirty condensers result in compressor failure and product loss. Please note product loss is not covered by warranty.

• To clean condenser, use a soft brush or vacuum with a shop vac or pressurized air

• If you can’t remove the debris adequately, please call an authorized refrigeration service company

Condenser Coil – tools required are; Phillips head screwdriver, stiff bristle brush and adjustable wrench

• Disconnect power to the unit

• Remove lower grill assembly by removing all the screws

• Remove bolts anchoring compressor assembly to frame rails and carefully slide out

• Clean off accumulated dirt from condensing coil with stiff bristle brush

• Lift cardboard cover above fan at plastic plugs and carefully clean condenser coil and fan blades

• After brushing condenser coil, vacuum dirt from coil and interior floor

• Replace cardboard cover, carefully slide compressor assembly back into position and replace bolts

• Re-install louver assembly onto unit with appropriate fasteners and clips and tighten screws

Plug unit back in and check to see if condenser is running

BB-48G

BB-60G

BB-72G

VER0413

Back Bar Coolers - Swing Glass Door - BB-48G, BB-60G, BB-72G

8

9

6

7

10

11

12

13

14

Reference

Number

1

2

3

4

5

19

20

21

22

23

24

15

16

17

18

25

26

27

40

41

42

43

36

37

38

39

44

45

32

33

34

35

28

29

30

31

VER0413

Quantity Description

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

2

1

1

6

1

1

18

4

8

9

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

CABINET

TOP BOARD

INNER DRAIN PAN

EVAPORATOR

FAN MOTOR INSTALLATION PANEL

EVAPORATOR FAN MOTOR

EVAPORATOR FAN MOTOR HOLDER

BLADE OF CONDENSER FAN MOTOR

EVAPORATOR COVER

TEMPERATURE CONTROL PANEL

MECHANICAL THERMOSTAT

TEMPERATURE CONTROL KNOB

LIGHT SWITCH

FRAME FOR MACHINE ROOM

COMPRESSOR UNIT INSTALLATION BOARD

CONDENSER

COMPRESSOR

SPLICE BOX

START CAPACITOR

OVERLOAD PROTECTOR

STARTER

CONDENSER FAN MOTOR

OUTER DRAIN PAN

FILTER FIXER

FILTER

INNER SHEET FOR MACHINE ROOM

SHEET FOR MACHINE ROOM

LEFT GLASS DOOR

GASKET

RIGHT GLASS DOOR

GASKET

BOTTOM RIGHT HINGE

LEFT BOTTOM HINGE

UPPER RIGHT HINGE

UPPER LEFT HINGE

PLATE OF LOCK FOR LEFT DOOR

PLATE OF LOCK FOR RIGHT DOOR

FIXED BLOCK FOR WORKTOP

K STRIP-4 HOLES

K CLIP

SHELF

LED LIGHT

DRAIN HOSE

POWER CORD

ADJUSTED FEET

(Page left blank on purpose)

WHAT IS NOT COVERED BY THIS WARRANTY

Admiral Crafts obligation under warranty is limited to either repair or replacement of parts, subject to the additional limitations below. This warranty neither assumes nor authorizes any person to assume obligations other than expressly covered by this warranty.

1. WARRANTY IS NOT TRANSFERABLE. This warranty is not assignable and applies in favor of the original purchaser/user to whom delivered. Any such assignment or transfer shall void the warranties herein made and shall void all warranties, express or implied, including any warranty of merchantability or fitness for a particular purpose.

2. NO CONSEQUENTIAL DAMAGES. Admiral Craft is not responsible for economic loss: profit loss or special, indirect, or consequential damages, including without limitation, losses or damages arising from food or product spoilage claims whether or not on account of refrigeration failure.

3. ALTERATION, NEGLECT, ABUSE, MISUSE, ACCIDENT, DAMAGE DURING TRANSIT OR INSTALLATION, FIRE,

FLOOD, ACTS OF GOD. Admiral Craft is not responsible for the repair or replacement of any parts that Admiral Craft determines have been subjected after the date of manufacture to alteration, neglect, abuse, misuse, accident, damage during transit or installation, fire, flood, or an Act of God.

4. NO IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. There are no other warranties, express, implied or statutory, except the one(1) year warranty and the additional four(4) year compressor warranty as described above. These warranties are exclusive and in lieu of all other warranties, including implied warranty and merchantability or fitness for a particular purpose. There are no warranties which extend beyond the description on the face hereof.

5. TRANSPORTATION COSTS. Admiral Craft will accept parts covered under this warranty freight collect, provided that shipment has received prior approval. Admiral Craft is not responsible for any other transporation costs, but will ship freight collect parts either repaired or replaced under these warranties.

6. WARRANTY CLAIMS. All claims should include: model number of the cooler, the serial number of the cabinet, proof of purchase, date of installation, and all pertinent information supporting the existence of the alleged defect. Any action or breach of these warranty provisions must be commenced within one (1) year after that cause of action has accused.

940 South Oyster Bay Rd

Hicksville, NY 11801

advertisement

Key Features

  • Swing glass doors
  • Requires dedicated circuit
  • Regular condenser cleaning needed
  • Level installation crucial
  • Proper ventilation required

Frequently Answers and Questions

How often should I clean the condenser?
Every 30 days.
What type of sealant should I use to secure the unit to the floor?
One of the NSF approved sealants listed in the manual.
What should I do if the power shuts off?
Wait 5 minutes before restarting the unit.
What happens if I don't follow the maintenance guidelines?
It may void the warranty.

Related manuals

Download PDF

advertisement