advertisement
Product Data Sheet
July 2015
00813-0200-2654, Rev KA
Rosemount
®
DIN-Style Temperature Sensors and Thermowells (Metric)
RTDs (0065) and thermocouples (0185) available to meet any process requirement
DIN-style for easy installation and replacement
Integrated temperature assembly with Rosemount transmitters available
Sensors and Accessories (Metric)
July 2015
Rosemount DIN-Style Temperature Sensor and
Thermowells
Optimize plant efficiency and increase measurement reliability with industry-proven design and specifications
Available in a wide variety of sensing technologies – RTD and thermocouples.
All sensor styles and lengths are available in 6 mm diameter
State of the art manufacturing procedures provide robust element packaging and increasing reliability
Industry-leading calibration capabilities allow for
Callendar-Van Dusen values to give increased accuracy when paired with Rosemount transmitters
Optional Class A accuracy for critical temperature measurement points
Streamline operations and maintenance with sensor and thermowell design
DIN style sensor uses connection heads that allow quick mounting and replacement while maintaining environmental integrity.
Terminal block, flying leads, and spring loaded threaded adapter styles offer remote or integral transmitter mounting configuration.
Explore the benefits of Complete Point
Solutions
™
from Rosemount Temperature
Measurement
An “Assemble Sensor to Specific Transmitter” option enables
Emerson
™
to provide a complete point temperature solution, delivering an installation-ready transmitter and sensor assembly.
Emerson has a complete portfolio of Single Point and High
Density Temperature Measurement solutions, allowing you to effectively measure and control your processes with the reliability you trust from Rosemount products.
Experience global consistency and local support from numerous worldwide Rosemount
Temperature manufacturing sites
World-class manufacturing provides globally consistent products from every factory and the capacity to fulfill the needs of any project, large or small.
Experienced instrumentation consultants help select the right product for any temperature application and advise on best installation practices.
An extensive global network of Emerson service and support personnel can be on-site when and where they are needed.
Content
Rosemount DIN-Style Sensor and Thermowell
. . . . . . . . . . . . . .
Rosemount Series 96 Barstock Thermowell . . . . . . . . . . . . . . . 18
Sensor Reference Information . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Sensor-to-Transmitter Matching
. . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . .
2 www.rosemount.com
July 2015
Sensors and Accessories (Metric)
Rosemount DIN-Style Sensor and Thermowell
The Rosemount DIN-Style Sensor and Thermowell have designs that provide flexible and reliable temperature measurements in process environments.
Features include:
Temperature range of -196 to 600 °C for RTD, -40 to 1000 °C for thermocouple
Industry-standard sensor types, including RTD and thermocouple varieties
DIN-style design for easy mounting and replacement
Variety of enclosure and connection head options
Global hazardous-location approvals available
Calibration services available to give you insight to sensor performance
MID calibration options for custody transfer
Assemble to transmitter option
Specification and selection of product materials, options, or components must be made by the purchaser of the equipment. See
for more information on Material Selection.
Table 1. Series 65 Platinum RTD and 185 Thermocouple Without Thermowell
★
The Standard offering represents the most common options. The starred options (
★
) should be selected for best delivery lead time.
__ The Expanded offering is subject to additional delivery lead time.
Model Product description
0065
0185
Pt 100 RTD (IEC 751) without thermowell
Thermocouple (IEC 584 Class 1) without thermowell
Connection head
9
K
R
7
8
J
H
L
C
D
1
2
N
G www.rosemount.com
Rosemount aluminum
Rosemount aluminum
Rosemount aluminum with LCD display meter cover
Rosemount aluminum with LCD display meter cover
No connection head
Rosemount stainless steel
Rosemount stainless steel
GR–A/BL (BUZ) aluminum w/cable gland
TZ–A/BL (BUZH) aluminum w/cable gland
Aluminum dual entry head
Aluminum dual entry head
Aluminum dual entry head
Stainless steel dual entry head
Stainless steel dual entry head
IP rating
66/68
65
65
66
66
66
66
66
66/68
66/68
66/68
66/68
N/A
66/68
(1)
Conduit/cable entry
M20
⫻
1.5
1
/
2
-in. NPT
M20
⫻
1.5
1
/
2
-in. NPT
N/A
M20
⫻
1.5
1
/
2
-in. NPT
M20
⫻
1.5
M20
⫻
1.5
2
⫻
3
/
4
-in. NPT
2
⫻
M20
⫻
1.5
2
⫻
1
/
2
-in. NPT
2
⫻ 3
/
4
-in. NPT
2
⫻
M20
⫻
1.5
★
★
★
★
★
3
Sensors and Accessories (Metric)
July 2015
W
A
P
Table 1. Series 65 Platinum RTD and 185 Thermocouple Without Thermowell
★
The Standard offering represents the most common options. The starred options (
★
) should be selected for best delivery lead time.
__ The Expanded offering is subject to additional delivery lead time.
Connection head
IP rating
(2)
Conduit/cable entry
Stainless steel dual entry head
TZ-A/BL (BUZH) aluminum coated
SD-BK
66
65
N/A
2
⫻
1
/
2
-in. NPT
M20
⫻
1.5
M20
⫻
1.5
Sensor lead wire termination
0
2
3
Sensor type
Flying leads – No springs on DIN plate
Terminal block – DIN 43762
Spring loaded adapter –
1
/
2
-in. NPT
1
2
3
RTD, single element, 4-wire
RTD, dual element, 3-wire
RTD, single element, 4-wire
4 RTD, dual element, 3-wire
03J1 Thermocouple, Type J, single element, ungrounded
03K1 Thermocouple, Type K, single element, ungrounded
05J1 Thermocouple, Type J, dual element, isolated, ungrounded
9
0
05K1 Thermocouple, Type K, dual element, isolated, ungrounded
7 RTD, Single element, 3 wire vibration resistance
RTD, Single element, 4 wire vibration resistance
RTD, Dual Element, 3 wire vibration resistance
03N1 Thermocouple, Type N, single element, ungrounded
Temperature range
– 50 to 450 °C (–58 to 842 °F)
– 50 to 450 °C (–58 to 842 °F)
–196 to 600 °C (–321 to 1112 °F)
–196 to 600 °C (–321 to 1112 °F)
– 40 to 750 °C (–40 to 1382 °F)
– 40 to 1000 °C (–40 to 1832 °F)
– 40 to 750 °C (–40 to 1382 °F)
– 40 to 1000 °C (–40 to 1832 °F)
– 60 to 600 °C (–76 to 1112 °F)
– 60 to 600 °C (–76 to 1112 °F)
– 60 to 600 °C (–76 to 1112 °F)
– 40 to 1000 °C (–40 to 1832 °F)
★
★
★
★
★
★
★
★
★
★
★
05N1 Thermocouple, Type N, dual element, isolated, ungrounded – 40 to 1000 °C (–40 to 1832 °F)
0000
0035
0080
4
0110
Extension
N
W
L
J
F
D
T
Extension length (N) in millimeters
Head connection
DIN Standard 12
⫻
1.5
DIN Standard 12
⫻
1.5
Nipple union nipple
Nipple union (M/F)
M24
⫻
1.5
M24
⫻
1.5
1
/
2
-in. NPT
N/A
No extension - only available with connection head code N
No extension head connection M24
⫻
1.5
No extension head connection
1
/
2
-in. NPT
No extension – Use with extension code N, W, or L
35 mm
80 mm – standard for Extension Type code J
110 mm – standard for Extension Type codes F and J
Instrument connection
1
/
2
-in. NPT
M18
⫻
1.5
1
/
2
-in. NPT
1
/
2
-in. NPT
Material
300 series stainless steel
★
300 series stainless steel
★
300 series stainless steel
★
300 series stainless steel
★
★
★
★
★
★
★
★ www.rosemount.com
July 2015
Sensors and Accessories (Metric)
Table 1. Series 65 Platinum RTD and 185 Thermocouple Without Thermowell
★
The Standard offering represents the most common options. The starred options (
★
) should be selected for best delivery lead time.
__ The Expanded offering is subject to additional delivery lead time.
0145
0205
0275
0315
0375
0405
0435
0555
XXXX
Extension length (N) in millimeters
0135
0150
XXXX
135 mm – standard for DIN Extension used with Rosemount Connection Head Material codes C, D, G, H, 1, and 2
★
150 mm – standard for DIN Extension used with Form B Connection Head Material codes J and L
★
Non-standard extension length – available from 35 to 500 mm in 5-mm increments
Thermowell material
N No thermowell
Sensor length (L) in millimeters
★
145 mm
205 mm
275 mm
315 mm
375 mm
405 mm
435 mm
555 mm
Non-standard sensor length available from 100 to 9999 mm in 5-mm increments
★
★
★
★
★
★
★
★
Options
(include with selected model number)
Sensor options (available with 65 only)
A1 Single element Class A sensor
A2 Dual element Class A sensor
Product certifications
(3)
Temperature range
–50 to 450 °C (–58 to 842 °F) (0 °C to 350 °C for sensor types 7,9,0)
–50 to 450 °C (–58 to 842 °F) (0 °C to 350 °C for sensor types 7,9,0)
E4
E6
E2
KD
KM
IM
ND
K1
E7
E5
I1
N1
E1
ATEX Intrinsic Safety Approval
ATEX Type n Approval
ATEX Flameproof Approval
ATEX Dust Approval
ATEX Flameproof, Intrinsic Safety, Type n, and Dust Approval
IECEx Flameproof Approval
US Explosionproof Approval
TIIS Flameproof Approval (consult factory for availability)
Canada Explosionproof Approval
Brazil Flameproof Approval
US Explosionproof, Canada Explosionproof, and ATEX Flameproof Approval
Technical Regulations Customs Union (EAC) Flameproof, Intrinsic Safety Approval
Technical Regulations Customs Union (EAC) Intrinsic Safety Approval
EM Technical Regulations Customs Union (EAC) Flameproof Approval www.rosemount.com
★
★
★
★
★
★
★
★
★
★
★
★
★
★
★
★
5
Sensors and Accessories (Metric)
July 2015
Table 1. Series 65 Platinum RTD and 185 Thermocouple Without Thermowell
★
The Standard offering represents the most common options. The starred options (
★
) should be selected for best delivery lead time.
__ The Expanded offering is subject to additional delivery lead time.
Ground screw
G1 External ground screw – only available with Rosemount connection head codes C, D, G, H, 1, and 2
Cable glands
★
G2
G4
G5
G7
Cable gland, EEx d, brass, diam 7.5-11.9 mm
Cable gland, M20
⫻
1.5 EMV, brass nickel coated, diam 9-13 mm
Cable gland, M20
⫻
1.5 EMV, brass nickel coated, diam 5-13 mm
Cable gland, M20
⫻
1.5, EEx e, blue, polyamide, diam 5-9 mm
Cover chain option
G3 Cover chain – only available with Rosemount connection head codes C, D, G, and H
Assemble to option
XA
(4)
Assemble sensor to specific temperature transmitter (PTFE paste)
★
Extension ring
G6
Termination
Aluminum extension ring for dual transmitter mounting – use with Rosemount connection head codes C and D
★
TB Terminal block for use with sensor termination code 3
★
★
Sensor calibration with works certificate (available with 65 only)
V10
V11
X8
Sensor calibration from –50 to 450 °C (–58 to 842 °F) with A, B, C, and Callendar-Van Dusen Constants
Sensor calibration from 0 to 100 °C (32 to 212 °F) with A, B, C, and Callendar-Van Dusen Constants
Sensor calibration over specified temperature range with A, B, C, and Callendar-Van Dusen Constants
★
★
★
VS system calibration (available with 65 only)
MD1
MD2
MD3
MID custody transfer, -196 °C to 0 °C (-321 to 32 °F)
MID custody transfer, -50 °C to 100 °C (-58 to 212 °F)
MID custody transfer, 50 °C to 200 °C (122 to 392 °F)
★
★
★
GOST calibration certificate
QG Calibration certificate and Russian GOST Verification Certificate
★
Temperature range option
LT Special materials to meet extended temperature range of -51 °C (-60 °F)
★
Typical model number: 0065 C 2 3 D 0150 N 0315 A1
1.
To maintain IP rating, use a suitable cable gland on the conduit connection thread. All threads must be sealed with a suitable sealing tape.
2.
To maintain IP rating, use a suitable cable gland on the conduit connection thread. All threads must be sealed with a suitable sealing tape.
3.
Refer to Table 7 on page 28 for limitation on options available with approvals.
4.
If ordering Assemble To Option XA with a transmitter, specify the same option on the transmitter model number.
6 www.rosemount.com
July 2015
Sensors and Accessories (Metric)
Specification and selection of product materials, options, or components must be made by the purchaser of the equipment. See
for more information on Material Selection.
Table 2. Series 65 Platinum RTD and 185 Thermocouple With Tubular Thermowell
★
The Standard offering represents the most common options. The starred options (
★
) should be selected for best delivery lead time.
__ The Expanded offering is subject to additional delivery lead time
Model
0065
0185
Product description
Pt 100 RTD (IEC 751) with tubular thermowell
Thermocouples (IEC 584 Class 1) with tubular thermowell
Connection head
A
P
9
K
R
W
J
L
7
8
2
N
G
H
C
D
1
Sensor lead wire termination
Rosemount aluminum
Rosemount aluminum
Rosemount aluminum with LCD display meter cover
Rosemount aluminum with LCD display meter cover
No connection head
Rosemount stainless steel
Rosemount stainless steel
GR –A/BL (BUZ) aluminum w/ cable gland
TZ–A/BL (BUZH) aluminum w/ cable gland
Aluminum dual entry head
Aluminum dual entry head
Aluminum dual entry head
Stainless steel dual entry head
Stainless steel dual entry head
Stainless steel dual entry head
TZ-A/BL (BUZH) aluminum coated
SD-BK
0
2
Sensor type
Flying leads – no springs on DIN plate
Terminal block – DIN 43762
1
2
3
RTD, single element, 4-wire
RTD, dual element, 3-wire
RTD, single element, 4-wire
4 RTD, dual element, 3-wire
03J1 Thermocouple, Type J, single element, ungrounded
03K1 Thermocouple, Type K, single element, ungrounded
05J1 Thermocouple, Type J, dual element, isolated, ungrounded
05K1 Thermocouple, Type K, dual element, isolated, ungrounded
IP rating
66
66
66
66
65
65
66
66
65
N/A
66/68
66/68
66/68
66/68
N/A
66/68
66/68
(1)
Conduit/cable entry
M20
⫻
1.5
1
/
2
-in. NPT
M20
⫻
1.5
1
/
2
-in. NPT
N/A
M20
⫻
1.5
1
/
2
-in. NPT
M20
⫻
1.5
M20
⫻
1.5
2
⫻
3
/
4
-in. NPT
2
⫻
M20
⫻
1.5
2
⫻
1
/
2
-in. NPT
2
⫻ 3
/
4
-in. NPT
2
⫻
M20
⫻
1.5
2
⫻
1
/
2
-in. NPT
M20
⫻
1.5
M20
⫻
1.5
Temperature range
– 50 to 450 °C (–58 to 842 °F)
★
– 50 to 450 °C (–58 to 842 °F)
★
–196 to 600 °C (–321 to 1112 °F)
★
–196 to 600 °C (–321 to 1112 °F)
★
– 40 to 750 °C (–40 to 1382 °F)
★
– 40 to 1000 °C (–40 to 1832 °F)
★
– 40 to 750 °C (–40 to 1382 °F)
★
– 40 to 1000 °C (–40 to 1832 °F)
★
★
★
★
★
★
★
★ www.rosemount.com
7
Sensors and Accessories (Metric)
July 2015
Table 2. Series 65 Platinum RTD and 185 Thermocouple With Tubular Thermowell
★
The Standard offering represents the most common options. The starred options (
★
) should be selected for best delivery lead time.
__ The Expanded offering is subject to additional delivery lead time
Temperature range
Sensor type
7
9
RTD, single element, 3 wire vibration resistance
RTD, single element, 4 wire vibration resistance
0 RTD, dual element, 3 wire vibration resistance
03N1 Thermocouple, Type N, single element, ungrounded
– 60 to 600 °C (-76 to 1112 °F)
– 60 to 600 °C (-76 to 1112 °F)
– 60 to 600 °C (-76 to 1112 °F)
– 40 to 1000 °C (–40 to 1832 °F)
05N1 Thermocouple, Type N, dual element, isolated, ungrounded – 40 to 1000 °C (–40 to 1832 °F)
Extension
Y
Z
Tubular, no extension - only available with form GN
Tubular, with extension-only available with form GB, NAMUR
Extension length (N) in millimeters
0000
0050
0065
0105
0115
0130
0200
0250
XXXX
No extension – use with extension code Y
50 mm
65 mm
105 mm
115 mm
130 mm
200 mm
250 mm
Non-standard extension length – available from 50 to 500 mm in 5-mm increments
Thermowell material
D
Y
Code
1.4404 (316L SST)
1.4571 (316Ti SST)
Immersion length (U)
0200
0220
0225
0250
0280
0300
0050
0075
0100
0115
0130
0150
0160
50 mm
75 mm
100 mm
115 mm
130 mm
150 mm
160 mm
200 mm
220 mm
225 mm
250 mm
280 mm
300 mm
8
★
★
★
★
★
★
★
★
★
★
★
★
★
★
★
★
★ www.rosemount.com
★
★
★
★
★
★
★
★
July 2015
Sensors and Accessories (Metric)
Code
0345
0400
XXXX
Code
L26
L32
H02
H08
L02
L08
L14
L20
H14
H20
H26
G63
G94
G72
G95
G40
G42
G52
G92
G24
G91
G31
G38
G02
G04
G06
G13
G20
G22
Table 2. Series 65 Platinum RTD and 185 Thermocouple With Tubular Thermowell
★
The Standard offering represents the most common options. The starred options (
★
) should be selected for best delivery lead time.
__ The Expanded offering is subject to additional delivery lead time
Immersion length (U)
345 mm
400 mm
Non-standard immersion length – available from 50 to 2500 mm in 5-mm increments
Thermowell mounting style Process connections
Threaded, tapered
Threaded, tapered
Threaded, tapered
Threaded, parallel
Threaded, parallel
Threaded, parallel
Threaded, parallel
Threaded, parallel
Threaded, parallel
Threaded, tapered
Threaded, tapered
Threaded, tapered
Threaded, parallel
Threaded, parallel
Threaded, parallel
Threaded, parallel
Threaded, parallel
Threaded, parallel
Flanged, RF
Flanged, RF
Flanged, RF
Flanged, RF
Flanged, RF
Flanged, RF
Flange, Form B1 according to EN 1092-1
Flange, Form B1 according to EN 1092-1
Flange, Form B1 according to EN 1092-1
Flange, Form B1 according to EN 1092-1
Flange, Form B1 according to EN 1092-1
R
1
/
2
-in. (
1
/
2
-in. BSPT)
R
3
/
4
-in. (
3
/
4
-in.BSPT)
R 1-in. (1-in. BSPT)
M27
⫻
2
G
1
/
2
-in. (
1
/
2
-in.BSPF)
G
3
/
4
-in. (
3
/
4
-in. BSPF)
G1 -in. (1-in. BSPF)
M20
⫻
1.5
M33
⫻
2
1
/
2
-in. NPT
3
/
4
-in. NPT
1-in. NPT
G
1
/
2
-in. (
1
/
2
-in. BSPF)
M20
⫻
1.5
G
1
/
2
-in. (
1
/
2
-in. BSPF)
M20
⫻
1.5
G
1
/
2
-in. (
1
/
2
-in. BSPF)
M20
⫻
1.5
1-in. 150 lbs
1
1
/
2
-in. 150 lbs
2-in. 150 lbs
1-in. 300 lbs
1
1
/
2
-in. 300 lbs
2-in. 300 lbs
DN 25 PN 16
DN 25 PN 25/40
DN 40 PN 16
DN 40 PN 25/40
DN 50 PN 40
Stem style
Stepped, NAMUR
(2)
Stepped, NAMUR
Stepped, NAMUR
Stepped, NAMUR
Stepped, NAMUR
Stepped, NAMUR
Stepped, NAMUR
Stepped, NAMUR
Stepped, NAMUR
Stepped, NAMUR
Stepped, NAMUR
Stepped, NAMUR
Straight, GN, D. 9
⫻
1 mm
(3)
Straight, GN, D. 9
⫻
Straight, GN, D. 11
⫻
2 mm
Straight, GN, D. 11
⫻
2 mm
Straight, GN, D. 9
⫻
Straight, GN, D. 9
⫻
Stepped, NAMUR
Stepped, NAMUR
Stepped, NAMUR
Stepped, NAMUR
Stepped, NAMUR
Stepped, NAMUR
Stepped, NAMUR
Stepped, NAMUR
Stepped, NAMUR
Stepped, NAMUR
Stepped, NAMUR
★
★
★
★
★
★
★
★
★
★
★
★
★
★
★
★
★
★
★
★
★
★
★
★
★
★
★
★
★
★
★ www.rosemount.com
9
Sensors and Accessories (Metric)
July 2015
Table 2. Series 65 Platinum RTD and 185 Thermocouple With Tubular Thermowell
★
The Standard offering represents the most common options. The starred options (
★
) should be selected for best delivery lead time.
__ The Expanded offering is subject to additional delivery lead time
Options
(include with selected model number)
Sensor options (available with 65 only)
A1 Single element Class A sensor
A2 Dual element Class A sensor
Product certifications
(4)
Temperature range
– 50 to 450 °C (–58 to 848 °F) (0 °C° to 350 °C for sensor types 7, 9, 0)
★
–50 to 450 °C (–58 to 842 °F) (0 °C to 350 °C for sensor types 7, 9, 0)
★
E5
E4
E6
E2
I1
N1
E1
ND
K1
E7
KD
KM
IM
EM
ATEX Intrinsic Safety Approval
ATEX Type n Approval
ATEX Flameproof Approval
ATEX Dust Approval
ATEX Flameproof, Intrinsic Safety, Type n, and Dust Approval
IECEx Flameproof Approval
US Explosionproof Approval
TIIS Flameproof Approval (consult factory for availability)
Canada Explosionproof Approval
Brazil Flameproof Approval
US Explosionproof, Canada Explosionproof, and ATEX Explosionproof Approval
Technical Regulations Customs Union (EAC) Flameproof, Intrinsic Safety Approval
Technical Regulations Customs Union (EAC) Intrinsic Safety Approval
Technical Regulations Customs Union (EAC) Flameproof Approval
Ground screw
G1 External ground screw – only available with Rosemount connection head codes C, D, G, H, 1, and 2
Cable glands
★
★
★
★
★
★
★
★
★
★
★
★
★
★
★
G2
G4
G5
G7
Cable gland, EEx d, brass, diam 7.5-11.9 mm
Cable gland, M20
⫻
1.5 EMV, brass nickel coated, diam 9-13 mm
Cable gland, M20
⫻
1.5 EMV, brass nickel coated, diam 5-13 mm
Cable gland, M20
⫻
1.5, EEx e, blue, polyamide, diam 5-9 mm
Cover chain option
G3 Cover chain – only available with Rosemount connection head codes C, D, G, and H
★
Extension ring
G6 Aluminum extension ring for dual transmitter mounting – use with Rosemount connection head codes C and D
★
Material certification
Q8 Thermowell material certification, DIN EN 10204 3.1
★
External pressure test
R01 Thermowell external pressure testing
★
10 www.rosemount.com
July 2015
Sensors and Accessories (Metric)
Table 2. Series 65 Platinum RTD and 185 Thermocouple With Tubular Thermowell
★
The Standard offering represents the most common options. The starred options (
★
) should be selected for best delivery lead time.
__ The Expanded offering is subject to additional delivery lead time
Dye test
R03 Thermowell dye penetration testing
Special cleaning
R04 Thermowell special cleaning
Assemble to options
XA
(5)
Assemble sensor to specific temperature transmitter (PTFE paste)
Sensor calibration with works certificate (available with 65 only)
V10
V11
X8
Sensor calibration from –50 to 450 °C (–58 to 842 °F) with A, B, C, and Callendar-Van Dusen Constants
Sensor calibration from 0 to 100 °C (32 to 212 °F) with A, B, C, and Callendar-Van Dusen Constants
Sensor calibration over specified temperature range with A, B, C, & Calendar-Van Dusen Constraints
Temperature range option
LT Special material to meet extended temperature range of -51 °C (-60 °F)
Typical model number: 0065 G 2 2 D 0135 D 0225 F70 Q8 R01 R07
★
★
★
★
★
★
★
1.
To maintain IP rating, use a suitable cable gland on the conduit connection thread. All threads must be sealed with a suitable sealing tape.
2.
The NAMUR stepped profile is available in both thermowell material options, however to maintain NAMUR compliance material code Y is required. 115 mm is the minimum immersion length stepped thermowells are available and is the minimum requirement to maintain NAMUR compliance however for lengths shorter than 115 mm a straight thermowell with a 8 mm OD will be provided.
3.
Not available with thermowell Material code D.
4.
Refer to Table 7 on page 28 for limitation on options available with approvals.
5.
If ordering Assemble To Option XA with a transmitter, specify the same option on the transmitter model number.
www.rosemount.com
11
Sensors and Accessories (Metric)
July 2015
Specification and selection of product materials, options, or components must be made by the purchaser of the equipment. See
for more information on Material Selection.
Table 3. Series 65 Platinum RTD and 185 Thermocouple With Barstock Thermowell
★
The Standard offering represents the most common options. The starred options (
★
) should be selected for best delivery lead time.
__ The Expanded offering is subject to additional delivery lead time.
A
P
9
K
R
W
J
L
7
8
2
N
G
H
C
D
1
Model
0065
0185
Product description
Pt 100 RTD (IEC 751) with barstock thermowell
Thermocouples (IEC 584 Class 1) with barstock thermowell
Connection head
Rosemount aluminum
Rosemount aluminum
Rosemount aluminum with LCD display meter cover
Rosemount aluminum with LCD display meter cover
No connection head
Rosemount stainless steel
Rosemount stainless steel
GR –A/BL (BUZ) aluminum w/ cable gland
TZ–A/BL (BUZH) aluminum w/ cable gland
Aluminum dual entry head
Aluminum dual entry head
Aluminum dual entry head
Stainless steel dual entry head
Stainless steel dual entry head
Stainless steel dual entry head
TZ-A/BL (BUZH) aluminum coated
SD-BK
0
2
3
Sensor lead wire termination
Sensor type
Flying leads – no springs on DIN plate
Terminal block – DIN 43762
Spring loaded adapter –
1
/
2
-in. NPT
3
4
1
2
RTD, single element, 4-wire
RTD, dual element, 3-wire
RTD, single element, 4-wire
RTD, dual element, 3-wire
03J1 Thermocouple, Type J, single element, ungrounded
03K1 Thermocouple, Type K, single element, ungrounded
05J1 Thermocouple, Type J, dual element, isolated, ungrounded
05K1 Thermocouple, Type K, dual element, isolated, ungrounded
IP rating
66
66
66
66
65
65
66
66
65
N/A
66/68
66/68
66/68
66/68
N/A
66/68
66/68
(1)
Conduit/cable entry
M20
⫻
1.5
1
/
2
-in. NPT
M20
⫻
1.5
1
/
2
-in. NPT
N/A
M20
⫻
1.5
1
/
2
-in. NPT
M20
⫻
1.5
M20
⫻
1.5
2
⫻
3
/
4
-in. NPT
2
⫻
M20
⫻
1.5
2
⫻
1
/
2
-in. NPT
2
⫻ 3
/
4
-in. NPT
2
⫻
M20
⫻
1.5
2
⫻
1
/
2
-in. NPT
M20
⫻
1.5
M20
⫻
1.5
Temperature range
– 50 to 450 °C (–58 to 842 °F)
★
– 50 to 450 °C (–58 to 842 °F)
★
–196 to 600 °C (–321 to 1112 °F)
★
–196 to 600 °C (–321 to 1112 °F)
★
– 40 to 750 °C (–40 to 1382 °F)
★
– 40 to 1000 °C (–40 to 1832 °F)
★
– 40 to 750 °C (–40 to 1382 °F)
★
– 40 to 1000 °C (–40 to 1832 °F)
★
★
★
★
★
★
★
★
★
12 www.rosemount.com
July 2015
Sensors and Accessories (Metric)
Table 3. Series 65 Platinum RTD and 185 Thermocouple With Barstock Thermowell
★
The Standard offering represents the most common options. The starred options (
★
) should be selected for best delivery lead time.
__ The Expanded offering is subject to additional delivery lead time.
Temperature range
Sensor type
7
9
0
RTD, single element, 3 wire vibration resistance
RTD, single element, 4 wire vibration resistance
RTD, dual element, 3 wire vibration resistance
03N1 Thermocouple, Type N, single element, ungrounded
– 60 to 600 °C (-76 to 1112 °F)
– 60 to 600 °C (-76 to 1112 °F)
– 60 to 600 °C (-76 to 1112 °F)
– 40 to 1000 °C (–40 to 1832 °F)
05N1 Thermocouple, Type N, dual element, isolated, ungrounded – 40 to 1000 °C (–40 to 1832 °F)
F
J
N
D
T
Extension
Head connection
DIN standard 12
⫻
1.5
DIN standard 12
⫻
1.5
Nipple union nipple
M24
⫻
1.5
M24
⫻
1.5
1
/
2
-in. NPT
Nipple union (M/F) None
No extension - only available with connection head code N
Instrument connection
1
/
2
-in. NPT
M18
⫻
1.5
1
/
2
-in. NPT
1
/
2
-in. NPT
Materials
300 stainless steel
300 stainless steel
300 stainless steel
300 stainless steel
0000
0035
0080
0110
0135
0150
XXXX
Extension length (N) in millimeters
No extension – use with extension code N
35 mm
80 mm – standard for Extension Type code J
110 mm – standard for Extension Type codes F and J
135 mm – standard for DIN Extension used with Rosemount Connection Head Material codes C, D, G, H, 1, and 2
★
150 mm – standard for DIN Extension used with Form B Connection Head Material codes J and L
★
★
★
★
★
Non-standard extension length – available from 35 to 500 mm in 5-mm increments
★
★
★
★
★
Thermowell material
J
K
P
Z
D
Y
A
Code
1.4404 (316L SST)
1.4571 (316Ti SST)
1.4401 (316 SST)
2.4819 (Alloy C-276)
1.5415 (A 204 Size A)
1.7380 (A 182-Grade F22)
1.7335 (A 182-Grade F11)
Immersion length (U)
★
★
0065
0075
0115
0125
65 mm
75 mm
115 mm
125 mm
0150
0225
150 mm
225 mm www.rosemount.com
★
★
★
★
★
★
13
Sensors and Accessories (Metric)
July 2015
Code
0300
0450
XXXX
Code
F16
F22
F28
F34
T48
F04
F10
T08
T10
T12
T26
(2)
T44
T46
D04
D10
D16
D22
D28
F40
F46
F52
F58
(3)
Table 3. Series 65 Platinum RTD and 185 Thermocouple With Barstock Thermowell
★
The Standard offering represents the most common options. The starred options (
★
) should be selected for best delivery lead time.
__ The Expanded offering is subject to additional delivery lead time.
Immersion length (U)
300 mm
450 mm
Non-standard immersion length – available from 50 to 1000 mm in 5-mm increments
Thermowell mounting style Process connections
Threaded
Threaded
Threaded
Threaded
Threaded
Threaded
Threaded
Threaded
Threaded
Threaded
Threaded
Threaded
Flanged, RF
Flanged, RF
Flanged, RF
Flanged, RF
Flanged, RF
Flanged, RF
Flanged, RF
Flanged, RF
Flanged, RF
Flanged, RF
Flanged, RF
Flanged, RF
Flanged, RF
Flanged, RF
Flange, Form B1 according to EN 1092-1
Flange, Form B1 according to EN 1092-1
Flange, Form B1 according to EN 1092-1
Flange, Form B1 according to EN 1092-1
Flange, Form B1 according to EN 1092-1
R
1
/
2
-in. (
1
/
2
-in. BSPT)
R
3
/
4
-in. (
3
/
4
-in.BSPT)
R 1-in. (1-in. BSPT)
G
1
/
2
-in. (
1
/
2
-in. BSPF)
G
3
/
4
-in. (
3
/
4
-in.BSPF)
G 1-in. (1-in. BSPF)
1
/
2
-in. NPT
3
/
4
-in. NPT
1-in. NPT
M27
⫻
2
M33
⫻
2
M20
⫻
1.5
1-in. 150 lbs
1
1
/
2
-in. 150 lbs
2-in. 150 lbs
1-in. 300 lbs
1
1
/
2
-in. 300 lbs
2-in. 300 lbs
1-in. 600 lbs
1
1
/
2
-in. 600 lbs
2-in. 600 lbs
1-in. 900/1500 lbs
1
1
/
2
-in. 900/1500 lbs
2-in. 900/1500 lbs
1
1
/
2
-in. 2500 lbs.
2-in. 2500 lbs.
DN 25 PN 16
DN 25 PN 25/40
DN 40 PN 16
DN 40 PN 25/40
DN 50 PN 40
Stem style
Tapered
Tapered
Tapered
Tapered
Tapered
Tapered
Tapered
Tapered
Tapered
Tapered
Tapered
Tapered
Tapered
Tapered
Tapered
Tapered
Tapered
Tapered
Tapered
Tapered
Tapered
Tapered
Tapered
Tapered
Tapered
Tapered
Tapered
Tapered
Tapered
Tapered
Tapered
★
★
★
★
★
★
★
★
★
★
★
★
★
★
★
★
★
★
★
★
★
★
★
★
★
★
★
★
★
★
★
★
★
14 www.rosemount.com
July 2015 www.rosemount.com
Sensors and Accessories (Metric)
Table 3. Series 65 Platinum RTD and 185 Thermocouple With Barstock Thermowell
★
The Standard offering represents the most common options. The starred options (
★
) should be selected for best delivery lead time.
__ The Expanded offering is subject to additional delivery lead time.
Stem style
Code
W10
W12
W14
W16
E01
(5)(6)
E02
E04
E05
Thermowell mounting style
Welded
Welded
Welded
Welded
D1 welded
D2 welded
D4 welded
D5 welded
Process connections
3
/
4
-in. pipe
1-in. pipe
1
1
/
4
-in. pipe
1
1
/
2
-in. pipe
24h7
24h7
24h7
24h7
Tapered
Tapered
Tapered
Tapered
Tapered
Tapered
Tapered
Tapered
★
★
★
★
★
★
★
★
Options
(include with selected model number)
Sensor options (available with 65 only)
I1
N1
E1
ND
K1
E7
E5
E4
E6
E2
KD
KM
IM
EM
A1 Single element Class A sensor
A2 Dual element Class A sensor
Product certifications
(8)
Temperature range
– 50 to 450 °C (–58 to 848 °F) (0 °C to 350 °C for sensor types 7, 9, 0)
★
–50 to 450 °C (–58 to 842 °F) (0 °C to 350 °C for sensor types 7, 9, 0)
★
ATEX Intrinsic Safety Approval
ATEX Type n Approval
ATEX Flameproof Approval
ATEX Dust Approval
ATEX Flameproof, Intrinsic Safety, Type n, and Dust Approval
IECEx Flameproof Approval
US Explosionproof Approval
TIIS Flameproof Approval (consult factory for availability)
Canada Explosionproof Approval
Brazil Flameproof Approval
USA Explosionproof, Canada Explosionproof, and ATEX Flameproof Approval
Technical Regulations Customs Union (EAC) Flameproof, Intrinsic Safety Approval
Technical Regulations Customs Union (EAC) Intrinsic Safety Approval
Technical Regulations Customs Union (EAC) Flameproof Approval
★
★
★
★
★
★
★
★
★
★
★
★
★
★
Ground screw
G1 External ground screw – only available with Rosemount connection head codes C, D, G, H, 1, and 2
★
G2
G4
G5
G7
Cable glands
Cable gland, EEx d, brass, diam 7.5-11.9 mm
Cable gland, M20
⫻
1.5 EMV, brass nickel coated, diam 9-13 mm
Cable gland, M20
⫻
1.5 EMV, brass nickel coated, diam 5-13 mm
Cable gland, M20
⫻
1.5, EEx e, blue, polyamide, diam 5-9 mm
15
Sensors and Accessories (Metric)
July 2015
Table 3. Series 65 Platinum RTD and 185 Thermocouple With Barstock Thermowell
★
The Standard offering represents the most common options. The starred options (
★
) should be selected for best delivery lead time.
__ The Expanded offering is subject to additional delivery lead time.
Cover chain option
G3 Cover chain – only available with Rosemount connection head codes C, D, G, and H
★
Extension ring
G6 Aluminum extension ring for dual transmitter mounting – use with Rosemount connection head codes C and D
★
Termination
TB Terminal block for use with sensor termination code 3
★
Material certification
Q8 Thermowell material certification, DIN EN 10204 3.1
★
External pressure test
R01 Thermowell external pressure testing
★
Internal pressure test
R22 Thermowell internal pressure testing
★
Dye test
R03 Thermowell dye penetration testing
★
Special cleaning
R04 Thermowell special cleaning
★
NACE approval
R05
(9)
Thermowell NACE approval
★
Plug/chain
R06 Stainless steel plug and chain
★
Weld options
R07 Full penetration weld - for flanged thermowells only
★
Wake frequency
R21 Wake frequency – thermowell strength calculation
★
Assemble to options
XA
(10)
Assemble sensor to specific temperature transmitter (PTFE paste)
★
Sensor calibration with works certificate (available with 65 only)
V10
V11
X8
Sensor calibration from –50 to 450 °C (–58 to 842 °F) with A, B, C, and Callendar-Van Dusen Constants
Sensor calibration from 0 to 100 °C (32 to 212 °F) with A, B, C, and Callendar-Van Dusen Constants
Sensor calibration over specified temperature range with A, B, C, & Calendar-Van Dusen Constants
★
★
★
VS system calibration
MD1
MD2
MD3
16
MID custody transfer, -196 °C to 0 °C (-321 to 32 °F)
MID custody transfer, -50 °C to 100 °C (-58 to 212 °F)
MID custody transfer, 50 °C to 200 °C (122 to 392 °F)
★
★
★ www.rosemount.com
July 2015
Sensors and Accessories (Metric)
Table 3. Series 65 Platinum RTD and 185 Thermocouple With Barstock Thermowell
★
The Standard offering represents the most common options. The starred options (
★
) should be selected for best delivery lead time.
__ The Expanded offering is subject to additional delivery lead time.
Temperature range option
LT Special material to meet extended temperature range of -51 °C (-60 °F)
Typical model number: 0065 G 2 2 D 0135 D 0225 F70 Q8 R01 R07
★
1.
To maintain IP rating, use a suitable cable gland on the conduit connection thread. All threads must be sealed with a suitable sealing tape.
2.
This mounting style is only available with the lagging length code T040.
3.
Full penetration weld option R07 is required with this mounting style.
4.
This mounting style has a minimum lagging length of 80 mm.
5.
Only available with Extension style T.
6.
This mounting style is only available with the lagging length code T075.
7.
This mounting style is only available with the lagging length code T135.
8.
Refer to Table 7 on page 28 for limitation on options available with approvals.
9.
Only available with thermowell Material codes D, J and A.
10. If ordering Assemble To Option XA with a transmitter, specify the same option on the transmitter model number.
www.rosemount.com
17
Sensors and Accessories (Metric)
July 2015
Rosemount Series 96 Barstock Thermowell
The Rosemount Series 96 Barstock Thermowell has designs that provide flexible and reliable temperature measurements in process environments.
Features include:
Threaded, flanged, and weld-in styles
Wake frequency calculations conforming to ASME PTC 19.3
NACE approval available
Variety of testing and certification options available
Specification and selection of product materials, options, or components must be made by the purchaser of the equipment. See
for more information on Material Selection.
Table 4. Series 96 Barstock Thermowell
★
The Standard offering represents the most common options. The starred options (
★
) should be selected for best delivery lead time.
__ The Expanded offering is subject to additional delivery lead time.
Model Product description
0096 Barstock thermowell
Thermowell material
(1)
0065
0075
0115
0125
0150
0225
0300
0450
XXXX
J
A
D
Y
K
P
Z
1.4404 (316L SST)
1.4571 (316Ti SST)
1.4401 (316 SST)
2.4819 (Alloy C-276)
1.5415 (204 Size A)
1.7380 (182 Grade-F22)
1.7335 (182Grade-F11)
Immersion length (L) in millimeters
65 mm – standard length for weld-in thermowells, E01 and E04
75 mm
115 mm
125 mm – standard length for weld-in thermowells, E02 and E05
150 mm
225 mm
300 mm
450 mm
Non-standard immersion length - available from 25 to 1000 mm in 5-mm increments
★
★
★
★
★
★
★
★
★
★
18 www.rosemount.com
July 2015
Sensors and Accessories (Metric)
Table 4. Series 96 Barstock Thermowell
★
The Standard offering represents the most common options. The starred options (
★
) should be selected for best delivery lead time.
__ The Expanded offering is subject to additional delivery lead time.
Thermowell mounting style
Stem style
T48
F04
F10
F16
F22
F28
F34
F40
F46
T08
T10
T12
T26
(2)
T44
T46
D22
D28
W10
W12
W14
W16
F52
F58
(3)
D04
D10
D16
Flange, RF
Flange, RF
Flange, RF
Flange, RF
Flange, RF
Flange, RF
Flange, RF
Flanged, RF
Flanged, RF
Flanged, RF
Flanged, RF
Flanged, RF
Thread
Thread
Thread
Thread
Thread
Thread
Thread
Thread
Thread
Thread
Thread
Thread
Flange, RF
Flange, RF
Flange, Form B1 according to EN 1092-1
Flange, Form B1 according to EN 1092-1
Flange, Form B1 according to EN 1092-1
Flange, Form B1 according to EN 1092-1
Flange, Form B1 according to EN 1092-1
Welded
Welded
Welded
Welded
Process connections
2-in. 300 lbs
1-in. 600 lbs
1
1
/
2
-in. 600 lbs
2-in. 600 lbs
1-in. 900/1500 lbs
1
1
/
2
-in. 900/1500 lbs
2-in. 900/1500 lbs
1
1
/
2
in 2500 lbs
2 in. 2500 lbs
DN 25 PN 16
DN 25 PN 25/40
DN 40 PN 16
DN 40 PN 25/40
DN 50 PN 40
3
/
4
-in. pipe
1-in. pipe
1
1
/
4
-in. pipe
1
1
/
2
-in. pipe
R
1
/
2
-in. (
1
/
2
-in. BSPT)
R
3
/
4
-in. (
3
/
4
-in.BSPT)
R 1-in. (1-in. BSPT)
G
1
/
2
-in. (
1
/
2
-in. BSPF)
G
3
/
4
-in. (
3
/
4
-in.BSPF)
G 1-in. (1-in. BSPF)
1
/
2
-in. NPT
3
/
4
-in. NPT
1-in. NPT
M27
⫻
2
M33
⫻
2
M20
⫻
1.5
1-in. 150 lbs
1
1
/
2
-in. 150 lbs
2-in. 150 lbs
1-in. 300 lbs
1
1
/
2
-in. 300 lbs
Tapered
Tapered
Tapered
Tapered
Tapered
Tapered
Tapered
Tapered
Tapered
Tapered
Tapered
Tapered
Tapered
Tapered
Tapered
Tapered
Tapered
Tapered
Tapered
Tapered
Tapered
Tapered
Tapered
Tapered
Tapered
Tapered
Tapered
Tapered
Tapered
Tapered
Tapered
Tapered
Tapered
Tapered
Tapered
★
★
★
★
★
★
★
★
★
★
★
★
★
★
★
★
★
★
★
★
★
★
★
★
★
★
★
★
★
★
★
★
★
★
★ www.rosemount.com
19
Sensors and Accessories (Metric)
July 2015
Table 4. Series 96 Barstock Thermowell
★
The Standard offering represents the most common options. The starred options (
★
) should be selected for best delivery lead time.
__ The Expanded offering is subject to additional delivery lead time.
Process connections Stem style
Thermowell mounting style
E01
(5)
E02
E04
(6)
E05
D1 welded, DIN
D2 welded, DIN
D4 welded, DIN
D5 welded, DIN
24h7
24h7
24h7
24h7
Tapered
Tapered
Tapered
Tapered
★
★
★
★
Lagging length
T040
T060
T075
T080
T135
TXXX
40 mm
60 mm
75 mm
80 mm
135 mm
Non standard lagging length
A
D
T
Instrument connection thread type
M24
⫻
1.5
1
/
2
-in. NPT
M18
⫻
1.5 – valid for weld-in thermowells codes E01, E02, E04 and E05
★
★
★
★
★
★
★
★
Options
(include with selected model number)
Material certification
Q8 Thermowell material certification
External pressure test
R01 Thermowell external pressure testing (flanged thermowells only)
Internal pressure test
R22
Dye test
Thermowell internal pressure test
R03 Thermowell dye penetration testing
Special cleaning
R04 Thermowell special cleaning
NACE approval
R05
(7)
Thermowell NACE approval
Plug/chain
R06 Stainless steel plug and chain
★
★
★
★
★
★
★
20 www.rosemount.com
July 2015
Sensors and Accessories (Metric)
Table 4. Series 96 Barstock Thermowell
★
The Standard offering represents the most common options. The starred options (
★
) should be selected for best delivery lead time.
__ The Expanded offering is subject to additional delivery lead time.
Weld options
R07
Flange type
Full penetration weld - for flanged thermowells only
R16 Ring joint flange face
Wake frequency calculation
R21 Wake frequency – thermowell strength calculation
Typical model number: 0096 D 0300 F04 T060 D Q8 R01
★
★
★
1.
Additional materials are available upon request.
2.
This mounting style is only available with the lagging length code T040.
3.
Full penetration weld option R07 is required with this mounting style.
4.
This mounting style has a minimum lagging length of 80 mm.
5.
This mounting style is only available with the lagging length code T075.
6.
This mounting style is only available with the lagging length code T135.
7.
Only available with thermowell material codes D, J and A.
www.rosemount.com
21
Sensors and Accessories (Metric)
July 2015
Sensor Reference Information
Overview
Rosemount integral mount temperature sensors, accessory hardware, and assemblies constitute a complete line of industrial temperature-sensing instruments. A variety of RTD and thermocouple sensors are available alone, or as complete assemblies including connection heads, thermowells, and extension fittings. Emerson Process Management offers complete temperature measurement assemblies including
Rosemount Smart and Programmable Temperature
Transmitters. Ask your Emerson representative for details.
Series 65 Platinum RTD Temperature Sensors are highly linear and have a stable resistance versus temperature relationship.
These sensors are used primarily in industrial environments where high accuracy, durability, and long-term stability are required. Series 65 Sensors are designed to meet the most critical parameters of international standards: IEC 751:1983,
Amendment 1:1986 and 2:1995 and DIN EN 60751:1996. This standardization provides sensor interchangeability without the need for transmitter circuitry adjustment.
Enhanced performance and optimal temperature measurement accuracy is available for Series 65 Sensors coupled with a range of
Rosemount Smart Temperature Transmitters through calibration schedules and Callendar-Van Dusen constants.
Series 185 Thermocouple Temperature Sensors conform to IEC
584:1982, Amendment 1:1989 and are available in types J, K and N. Series 185 Sensors are available single ungrounded, or dual ungrounded, isolated.
All sensors are available in a variety of lengths
(1)
and ranges with flying lead, terminal block, or
1
/
2
-in. NPT spring-loaded adapter lead wire terminations.
In addition to complete assemblies, Emerson offers a selection of separate accessory hardware including connection heads and thermowells.
1.
Sensors over one meter long will be supplied coiled unless otherwise requested.
Choosing an extension and thermowell
Aside from ambient temperature variations, heat from the process, in a direct mounting configuration, is transferred from the thermowell to the transmitter housing. If the expected process temperature is near or beyond the transmitter specification limits, consider the use of additional thermowell extension length, an extension nipple, or a remote mounting configuration to isolate the transmitter from these excessive temperatures.
provides an example of the relationship between transmitter housing temperature rise and extension length. Use
and the accompanying example as a guide for determining adequate thermowell extension length.
Figure 1. Transmitter Housing Temperature Rise vs. Uninsulated Extension Length
60
50
40
30
20
10
5
40
8
1
5
°C
°C
P ro ce ss T emp
Pr oce eratu re
250
°C Proc ss Tem peratur e ess Temperature
0
75 100 125 150 175 200 225
Uninsulated Extension “N” Length (mm)
Example
The rated ambient temperature specification for the transmitter is 85 °C. If the maximum ambient temperature is 40 °C and the temperature to be measured is 540 °C, the maximum allowable housing temperature rise is the rated temperature specification limit minus the existing ambient temperature (85 – 40), or
45 °C.
As shown in
, an “N” dimension of 90 mm will result in a housing temperature rise of 22 °C. An “N” dimension of 100 mm would therefore be the minimum recommended length, and would provide a safety factor of about 25 °C. A longer “N” dimension, such as 150 mm, would be desirable in order to reduce errors caused by transmitter temperature effect, although in that case the transmitter may require extra support.
22 www.rosemount.com
July 2015
Sensors and Accessories (Metric)
Integral mount sensors and assemblies
Series 65 RTD and Series 185 Thermocouple Temperature
Sensors may be ordered as complete assemblies, which provide a complete, yet simple, means of specifying the proper industrial hardware for most temperature measurements. One assembly model number, derived from one ordering table, completely defines the type of sensing element, as well as the material, length, and style of extension fittings and thermowells.
All sensor assemblies are sized and inspected by Emerson to ensure complete component compatibility and performance.
Mounting configurations
Series 65 Platinum RTDs and Series 185 Thermocouples
You may order the Series 65 RTDs and the Series 185
Thermocouples with flying leads, a terminal block, or a
1
/
2
-in.
NPT spring-loaded adapter.
Ordered with flying leads, the sensors are designed to be used with a head-mount temperature transmitter attached directly to the sensor. The flying lead configuration allows the removal of the sensor and transmitter as one assembly.
The BUZH connection head allows terminal block style sensors and transmitters to be mounted together. The transmitters in these assemblies will be mounted in the cover of the BUZH connection head.
The sensors with a
1
/
2
-in. NPT spring-loaded adapter are used with directly mounted 3144P field-mount temperature transmitters or through the use of Rosemount connection heads. This assembly requires a terminal block to be mounted inside the head.
Hazardous area approvals are available with all three types of sensors, but they are dependent on the configuration of the
entire temperature measurement assembly (see “Product
Temperature considerations
Ambient temperature limits for the connection head are -40 °C to +85 °C. The LT Option may be extended down to a range of
-51 °C to +85 °C.
Ambient temperature range addresses the connection head only, and requires suitable cable glands and field wiring provisions to meet the temperature requirements below -40 °C.
Figure 2. Series 65 RTD Lead Wire Configuration
Series 65 RTD Flying Leads and spring-loaded adapter-termination codes 0 or 3 only
Single element Dual element
White
White
Red
Red
Black
Blue
Blue
Red
Red
Green
Series 65 RTD Terminal Block termination code 2
Single element Dual element
Red
Red
White
White
4
3
1
6
1
6
3
4
3 Red
2 Red
1 White
1
2
3
6 Red
5 Red
4 White
6
5
4
Figure 3. Series 185 Lead Wire Configuration
Series 185 RTD Thermocouple Terminal Block
Single element Dual element
3 (-)
1 (+)
3 (-)
1 (+)
1 3
1
6
3
4
6 (-)
4 (+) www.rosemount.com
23
Sensors and Accessories (Metric)
July 2015
Specifications
Series 65 Platinum RTD
100
Ω
RTD at 0 °C,
α
= 0.00385 °C
-1
Temperature range
–50 to 450 °C or –196 to 600 °C depending on type
Self heating
0.15 °C/mW when measured per method defined in
IEC 751:1983, Amendments 1 & 2
Thermal response time
9 seconds maximum required to reach 50% sensor response when tested in flowing water according to IEC 751:1983,
Amendments 1 & 2
Immersion error
60 mm minimum usable depth of immersion when tested according to IEC 751:1983, Amendments 1 & 2
Insulation resistance
1,000 M
Ω
minimum insulation resistance when measured at
500 Vdc and at room temperature
Sheath material
316SST sensor tip (hot end) with 321SST mineral insulated cable construction
Lead wire
PTFE insulated, silver-coated, 0.21mm
²
(24 AWG) stranded
copper wire. See Figure 2 for wire configuration.
Identification data
The model and serial numbers are marked on each sensor
Ingress protection (IP) ratings
The Rosemount connection head is rated to IP66/IP68 and
NEMA
®
4X. The BUZ and BUZH connection heads are rated to
IP65. To maintain IP rating at installation, one of the following options must be used with the connection head:
Extension and/or adapter and barstock thermowell
Tubular thermowell
Sensor and sealing screw (extension option “V”)
General purpose adapter
Vibration limits
For sensor types option code “1”, “2”, “3”, and “4”, the vibration resistance is ±0.02% (0.05 °C) maximum ice-point resistance shift after 3 g vibration between 10 and 500 Hz for 150 hours according to IEC 751:1983, Amendments 1 and 2.
For sensor types option code “7”, “9”, and “0”, the vibration resistance is ±0.02% (0.05 °C) maximum ice-point resistance shift after 10 g vibration between 10 and 500 Hz for 150 hours according to IEC 751:1983, Amendments 1 and 2.
Table 5. Series 65 Interchangeability
Standard series 65 IEC-751 class B Temperature
±0.80 °C (±1.44 °F)
±0.30 °C (±0.54 °F)
±0.80 °C (±1.44 °F)
±1.80 °C (±3.24 °F)
±2.30 °C (±4.14 °F)
-100 °C (-148 °F)
0 °C (32 °F)
100 °C (212 °F)
300 °C (572 °F)
400 °C (752 °F)
Series 65 with IEC-751 class A option Temperature
±0.35 °C (±0.63 °F)
±0.15 °C (±0.27 °F)
±0.35 °C (±0.63 °F)
±0.75 °C (±1.35 °F)
±0.95 °C (±1.71 °F)
-100 °C (-148 °F)
0 °C (32 °F)
100 °C (212 °F)
300 °C (572 °F)
400 °C (752 °F)
24 www.rosemount.com
July 2015
Sensors and Accessories (Metric)
Series 185 Thermocouple
Construction
A thermocouple consists of a junction between two dissimilar metals that produces a change in thermoelectric emf in relationship to a change in temperature. Rosemount Series 185 thermocouple sensors are manufactured from selected materials to meet IEC 584 Tolerance Class 1. The junction of these wires is welded to form a pure joint, maintaining the integrity of the circuit and ensuring the highest accuracy.
Ungrounded junctions are protected from the environment by the sensor sheath. The ungrounded and isolated junctions provide electrical isolation from the sensor sheath.
Sheath material
Rosemount thermocouples are made of a mineral insulated cable design with a variety of sheath materials available to suit both the temperature and the environment. For temperatures up to 800 °C in air, 1.4541 (321 SST) is standard. For temperatures from 800 to 1100 °C in air, 2.4816 (Alloy 600) is standard. For temperatures above 1100 °C, precious metal or ceramic protective sheaths are available upon request. For strongly oxidising or reducing atmospheres, consult your local
Emerson representative.
Lead wires
PTFE insulated, 0.52 mm
²
(20 AWG) stranded thermocouple wire. Color coded per IEC 584. See
for wire configuration.
Identification data
The model and serial numbers are marked on each sensor.
Insulation resistance
1,000 M
Ω
minimum insulation resistance when measured at
500 Vdc and at room temperature.
Ingress protection (IP) ratings
The Rosemount connection head is rated to IP66/IP68 and
NEMA 4X. The BUZ and BUZH connection heads are rated to
IP65. To maintain IP rating at installation, one of the following options must be used with the connection head:
Extension and/or adapter and barstock thermowell
Tubular thermowell
Sensor and sealing screw (Extension option “V”)
General purpose adapter
Table 6. Characteristics of Series 185 Thermocouples
Type
J
K
N
Alloys (wire color)
Fe (+ black), CuNi (– white)
NiCr (+ green), NiAl (– white)
NiCrSi (+ pink), NiSi (- white)
Sheath material Temp. range (°C)
1.4541 (321 SST)
2.4816 (Alloy 600)
2.4816 (Alloy 600)
– 40 to 750
– 40 to 1000
– 40 to 1000
Limits of error (°C)
(whichever is greater)
Tolerance class
±1.5 or ±0.4%
±1.5 or ±0.4%
±1.5 or ±0.4%
1
1
1
Material selection
Emerson provides a variety of Rosemount product with various product options and configurations including materials of construction that can be expected to perform well in a wide range of applications. The Rosemount product information presented is intended as a guide for the purchaser to make an appropriate selection for the application. It is the purchaser’s sole responsibility to make a careful analysis of all process parameters (such as all chemical components, temperature, pressure, flow rate, abrasives, contaminants, etc.), when specifying product, materials, options and components for the particular application. Emerson Process
Management is not in a position to evaluate or guarantee the compatibility of the process fluid or other process parameters with the product, options, configuration or materials of construction selected.
www.rosemount.com
25
Sensors and Accessories (Metric)
July 2015
Product Certifications
Rev 1.0
European Directive Information
A copy of the EC Declaration of Conformity can be found at the end of the Quick Start Guide.The most recent revision of the EC
Declaration of Conformity can be found at www.emersonprocess.com.
Hazardous Location Certifications
USA
E5
FM Explosion proof and Dust-Ignition proof
Certificate: 0R7A2.AE
Standards: FM Class 3600: 2011; FM Class 3611: 2004;
FM Class 3615: 2006; FM Class 3810: 2005;
ANSI/NEMA - 250: 1991
Markings: XP CL I, Div 1, GP B, C, D;
DIP CL II/III, Div 1, GP E, F, G;
T6 (-50 °C
≤
T a
≤
+155 °C); Type 4X
Canada
E6
CSA Explosion proof and Dust-Ignition proof
Certificate: 1063635
Standards: CSA C22.2 No. 0-M91;
CSA C22.2 No. 25-1966;
CSA C22.2 No. 30-M1986;
CSA C22.2 No. 94-M91;
CSA C22.2 No. 142-M1987;
CSA C22.2 No. 213-M1987
Markings: XP CL I, Div 1, GP B, C, D;
DIP CL II/III, Div 1, GP E, F, G;
CL I, Div 2, GP A, B, C, D; (-50 °C
≤
T a
≤
+85 °C)
Europe
E1
ATEX
Certificate: FM12ATEX0065X
Standards: EN 60079-0:2012; EN 60079-1: 2007
Markings: II 2 G Ex d IIC T6…T1 Gb,
T6(-50 °C
≤
T a
≤
+40 °C),
T5…T1(-50 °C ≤ T a
≤ +60 °C);
1180
Special Conditions for Safe Use (X):
1. See certificate for ambient temperature range.
2. The non-metallic label may store an electrostatic charge and become a source of ignition in Group III environments.
3. Guard the LCD cover against impact energies greater than
4 joules.
4. Consult the manufacturer if dimensional information on the flameproof joints is necessary.
26
5. A suitable certified Ex d or Ex tb enclosure is required to be connected to temperature probes with Enclosure option
“N”.
6. Care shall be taken by the end user to ensure that the external surface temperature on the equipment and the neck of DIN Style Sensor probe does not exceed 130 °C.
I1
ATEX Intrinsic Safety
Certificate: IBExU03ATEX1066X
Standards: EN 60079-0:2012, EN 6079-11:2012,
EN 60079-26:2007
Markings: II 1 G Ex ia IIC T6; II 1/2 G Ex ia IIC T6;
II 2 G Ex ia IIC T6;
1180
Special Conditions for Safe Use (X):
1. The installation and the operation of the temperature sensors has to be carried out according to the requirements of the operating instructions.
2. The maximum permissible temperatures of the medium are dependent on the electric output of the supply in case of failure.
3. With maintenance of the collar-tube distance have to be guaranteed the maximum permissible ambient temperatures.
4. The maximum ambient temperature for use in Category 1
G is 60 °C.
N1
ATEX Type n
Certificate: BAS00ATEX3145
Standards: EN 60079-0:2012, EN 60079-15:2010
Markings: II 3 G Ex nA IIC T5 Gc (-40 °C ≤ T a
≤ +70 °C);
1180
ND
ATEX Dust
Certificate: FM12ATEX0065X
Standards: EN 60079-0:2012; EN 60079-31: 2009
Markings: II 2 D Ex tb IIIC T130 °C Db
(-40 °C
≤
T a
≤
+70 °C);
1180
Special Conditions for Safe Use (X):
1. See certificate for ambient temperature range.
2. The non-metallic label may store an electrostatic charge and become a source of ignition in Group III environments.
3. Guard the LCD cover against impact energies greater than
4 joules.
4. Consult the manufacturer if dimensional information on the flameproof joints is necessary.
5. A suitable certified Ex d or Ex tb enclosure is required to be connected to temperature probes with Enclosure option
“N”
6. Care shall be taken by the end user to ensure that the external surface temperature on the equipment and the neck of DIN Style Sensor probe does not exceed 130 °C.
www.rosemount.com
July 2015
Sensors and Accessories (Metric)
International
E7
IECEx Flameproof
Certificate: IECEx FMG 12.0022X
Standards: IEC 60079-0:2011; IEC 60079-1: 2007-04
Markings: Ex d IIC T6…T1 Gb, T6(-50 °C
≤
T a
T5…T1(-50 °C
≤
T a
≤
+60 °C)
≤
+40 °C),
Special Conditions for Safe Use (X):
1. See certificate for ambient temperature range.
2. The non-metallic label may store an electrostatic charge and become a source of ignition in Group III environments.
3. Guard the LCD cover against impact energies greater than
4 joules.
4. Consult the manufacturer if dimensional information on the flameproof joints is necessary.
5. A suitable certified Ex d or Ex tb enclosure is required to be connected to temperature probes with Enclosure option
“N”.
6. Care shall be taken by the end user to ensure that the external surface temperature on the equipment and the neck of DIN Style Sensor probe does not exceed 130 °C.
Brazil
E2
INMETRO Flameproof
Certificate: UL-BR 13.0535X
Standards: ABNT NBR IEC 60079-0: 2008 + Corrigendum
1:2011; ABNT NBR IEC 60079-1: 2009 +
Corrigendum 1:2011
Markings: Ex d IIC T6…T1* Gb T6…T1*:
(-50 °C ≤ T a
≤ +40 °C),
T5…T1*: (-50 °C ≤ T a
≤ +60 °C)
Special Conditions for Safe Use (X):
1. See product description for ambient temperature limits and process temperature limits.
2. Guard the LCD cover against impact energies greater than
4 joules.
3. Consult the manufacturer if dimensional information on the flameproof joints is necessary.
Japan
E4
Japan Flameproof (0065 only)
Certificate: TC17226
Markings: IIC T6; (-20 °C ≤ T a
≤ +65 °C);
Process Temperature: -20 °C to +85 °C
Special Condition for Safe Use (X):
1. The wiring shall be suitable for a temperature over 80 °C.
EAC – Belarus, Kazakhstan, Russia
EM
Technical Regulation Customs Union (EAC) Flameproof
Certificate: RU C-US.GB05.B.00289
Markings: 1Ex d IIC T6…T1 Gb X
Special Condition for Safe Use (X):
1. See certificate for special conditions.
IM
Technical Regulation Customs Union (EAC) Intrinsic Safety
Certificate: RU C-US.GB05.B.00289
Markings: 0Ex ia IIC T6 Ga X; Ga/Gb Ex ia IIC T6 X;
1Ex ia IIC T6 Gb X
Special Condition for Safe Use (X):
1. See certificate for special conditions.
Combinations
KD
Combination of E1, E5, and E6
K1
Combination of E1, I1, N1, and ND
KM
Combination of EM and IM www.rosemount.com
27
Sensors and Accessories (Metric)
July 2015
Table 7. Available Safety Approvals with Model Code Options
Model code
Description
C
D
1
2
J
L
7
N
G
H
8
9
K
Rosemount Aluminum
Rosemount Aluminum
Rosemount Aluminum with LCD Display Meter
Cover
Rosemount Aluminum with LCD Display Meter
Cover
No Connection Head
Rosemount Stainless steel
Rosemount Stainless steel
GR-A/BL (BUZ) Aluminum w/ Cable Gland
BL (BUZH) Aluminum w/ Cable Gland
Aluminum Dual Entry Head
Aluminum Dual Entry Head
Aluminum Dual Entry Head
Stainless Steel Dual Entry Head
R Stainless Steel Dual Entry Head
W Stainless Steel Dual Entry Head
A TZ-A/BL (BUZH) Aluminum Coated
P
Z
SD-BK
ZW-BL
G1 External Ground Screw
G6
Aluminum Extension Ring for Dual Transmitter
Mounting
Approval code
Conduit entry
I1 N1 E1 E2 ND E7 E5 E4 E6 KD
M20
⫻
1.5
1
/
2
-in. NPT
Y Y
Y Y
Y
Y
Y Y Y Y N
Y Y Y Y Y
N N
Y Y
M20
⫻
1.5
1
/
2
-in. NPT
N/A
M20
⫻
1.5
1
/
2
-in. NPT
Y
Y
Y
Y
Y Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
N
N
Y Y Y Y N
M20
⫻
1.5
M20
⫻
1.5
Y
Y
N
N
N
N
N
N
N
N
N
N
N
N
N
N
2
⫻ 3
/
4
-in. NPT Y N Y N N N N N
2
⫻
M20
⫻
1.5
Y N Y N N N N N
2
⫻ 1
/
2
-in. NPT Y N Y N N N N N
2
⫻
3
/
4
-in. NPT Y N Y N N N N N
2
⫻
M20
⫻
1.5
Y N Y N N N N N
2
⫻
1
/
2
-in. NPT Y N Y N N N N N
M20
⫻
1.5
M20
⫻
1.5
M20
⫻
1.5
Y
Y
Y
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N/A Y N Y N N N Y N
N/A
Y Y
Y Y
Y
Y
Y Y Y Y N
Y Y Y Y N
Y N Y N N N N N
N N
Y Y
N N
N N
N N
N N
N N
N N
Y N
Y Y
N N
Y Y
N N
N N
N N
N N
N N
N N
Note
Refer to this table to determine which approvals are available with each connection head option code.
28 www.rosemount.com
July 2015
Sensors and Accessories (Metric)
Sensor-to-Transmitter Matching
Significant measurement accuracy improvements can be attained using a temperature sensor that is matched to a temperature transmitter. This process involves identifying the relationship between resistance and temperature for a specific
RTD sensor. This relationship, approximated by the
Callendar-Van Dusen equation, is described as:
R t
= R o
+ R o
α
[t –
δ
(0.01t – 1)(0.01t) –
β
(0.01t – 1)(0.01t)
3
], where:
R t
= Resistance (ohms) at Temperature t (°C)
R o
= Sensor-Specific Constant (Resistance at t = 0 °C)
α
= Sensor-Specific Constant
δ
= Sensor-Specific Constant
β
= Sensor-Specific Constant (0 at t > 0 °C)
The exact values for the Callendar-Van Dusen constants (Ro,
α
,
δ
,
β)
are specific to each RTD sensor and are established by testing each individual sensor at various temperatures.
Series 65 RTD sensors can be ordered with the Calibration
Option codes V10 or V11, where the values of all four sensor-specific constants are supplied with each sensor.
The transmitter uses the Callendar-Van Dusen constants to generate a sensor curve that describes the relationship between resistance and temperature for this particular sensor and transmitter assembly. By using the sensors actual resistance vs. temperature curve, there is a 3- or 4-fold improvement in temperature measurement accuracy for the total system.
Options V10 and V11 are specific to a particular temperature range. As with calibration schedules, the accuracies associated with each option code represent worst-case conditions when the sensor is used over the entire temperature range. The accuracy of Series 65 sensors with the “V” option will vary because they have different hysteresis and repeatability characteristics. To ensure optimal performance, select a “V” option where the sensor’s range of actual operation is between the minimum and maximum calibration points. For applications requiring the use of a Resistance vs. Temperature Table, order a temperature range-specific characterization schedule.
IEC 751 interpretation
The Callendar-Van Dusen equation is one method of describing the resistance versus temperature (R vs.T) relationship for platinum RTDs. International standard IEC 751 interprets the R vs. T relationship using an approach similar to the Callendar-Van
Dusen methodology. The IEC 751 R vs.T relationship standard uses the following equation:
R t
= R o
[1 + At + Bt
2
+ C (t-100)t
3
]
As in the Callendar-Van Dusen method, R o
, A, B, C are specific to each RTD and are established by testing each sensor at various temperatures. The actual values for A, B, and C differ in magnitude from the Callendar-Van Dusen constants (R o
,
α
,
β
,
δ
), while R o
is the same in both equations. Either methodology yields the same result in any sensor-to-transmitter matching scenario, since one equation is a simple mathematical interpretation of the other.
www.rosemount.com
29
Sensors and Accessories (Metric)
July 2015
Typical sensor–to–transmitter matching accuracy improvements
Transmitter: Rosemount 3144P (has built-in sensor matching capabilities), span of 0 to 200 °C, accuracy = 0.1 °C)
Sensor: Series 65 RTD
Callendar-Van Dusen Option: V10
Process temperature: 150 °C
System uncertainty comparison at 150 °C
1.0 °C
0.75 °C
0.5 °C
Standard With Sensor
Matching
Standard 65 Sensor
Rosemount 3144P:
Standard Series 65 RTD:
Total System
(1)
:
65 Sensor with V10 Option
Rosemount 3144P:
Calibrated Sensor Series 65 RTD:
:
1.
Calculated using RSS statistical method:
System accuracy =
(
Transmitter
A ccuracy
)
2
+
(
SensorAccuracy
)
2
± 0.10 °C
± 1.05 °C
± 1.05 °C
± 0.10 °C
± 0.18 °C
± 0.21 °C
Calibration
Sensor calibration may be required for input to quality systems, or for control system enhancement. More frequently, it is used to improve the overall temperature measurement performance by matching the sensor to a temperature transmitter. Sensor matching is available for RTD sensors used with Rosemount Smart transmitters where the inherent stability and repeatability of the RTD technology is well established.
Ordering information
Use the formats presented below to order a calibrated Series 65 RTD. If you fail to specify all of the necessary calibration-related information when you place your order, Emerson will contact you for the information and your order may be delayed slightly.
Measurement instrument directive parts certification
The Rosemount 3144P Temperature Transmitter and Rosemount 0065 Temperature Sensor have been certified to meet the
European Union Measurement Instrument Directive (MID) for custody transfer metering of liquids and gases
(1)
. Choosing Rosemount
Temperature for a MID solution ensures that critical temperature measurement equipment will meet high expectations for unmatched system accuracy and reliability. For more information, contact your local Emerson Process Management Representative.
Calibration options
The X8 option calibrates the sensor to a customer-specific temperature range. The Callendar-Van Dusen, and A, B, and C-constants are supplied with a works certificate.
1.
Calculate using RSS statistical method:
System accuracy =
(
Transmitter
A ccuracy
)
2
+
(
SensorAccuracy
)
2
30 www.rosemount.com
July 2015
Sensors and Accessories (Metric)
Option X8: sensor calibrated to a customer-specified temperature range (see
)
When you order an RTD with the X8 option, the temperature range the sensor needs to be calibrated must be specified. Take note of the sensor temperature limits as shown below.
Typical model number
Model Connection head Lead wire termination
0065 C 2
Extension length Thermowell material Immersion length
Sensor type
1
Extension type
D
Mounting style Additional options
0135 D 0225 T12 X8
Note
Calibrate from –10 to 120 °C.
Option V: sensor calibration with works certificate
Temperature range (°C)
Calibration points (°C)
V10
–50 to +450
–50
0
+100
+450
V11
0 to +100
0
+50
+100
Figure 4. Sensor Assembly Without Thermowell
644 with LCD Display Meter
Head or field mount transmitters
644 248
Code
V13
0 to +600
0
+100
+600
V15
–196 to +600
–196
0
+100
+600
V16
–50 to +100
–50
0
+50
+100
3144
IP68 or IP65
Connection Heads
40 mm
25 mm
Sensor with Flying Leads,
Terminal Block, or
Spring-Loaded Adapter
L L
11 mm
L
16 mm
Extensions
★★
N dimension measures from thread
engagement point www.rosemount.com
N
★★
N
★★
N
★★
31
Sensors and Accessories (Metric)
July 2015
Figure 5. Series 65 RTD and Series 185 Thermocouple Dimensional Drawings
ATEX/CENELEC EEx d flameproof and
IECEx/FM explosion-proof approved
Non-approved
Terminal block Flying leads Terminal block Flying leads
1 /
2
- NPT spring loaded adapter
41
41
41 41
33
33
33
33
L
21
8.00
L
21
8.00
L
8.0
9.0
L
8.0
9.0
L
11±2
Series
65 Single Element
65 Dual Element
185 Single Element
185 Dual Element
Sensor diameter Number of leads
6.0
6.0
6.0
6.0
2
4
4
6
Lead wire length
(flying leads)
Element 1 Element 2
150
150
100
100
N/A
200
N/A
200
Lead wire length
(spring loaded)
Element 1 Element 2
150
150
150
150
N/A
200
N/A
200
32 www.rosemount.com
July 2015
Figure 6. Tubular Thermowell Sensor Assemblies
644 with LCD Display Meter
644
Head or field mount transmitters
IP68 OR IP65,
Connection
Heads
40 mm
Sensor with flying leads or terminal block
248
25 mm
Sensors and Accessories (Metric)
Threaded and flanged tubular thermowells
N
U
N
★★
U
N
★★
U
U
★★
NAMUR
NAMUR GB
★★
For straight threading, N dimension references bottom of hex.
For tapered threading, N dimensionreferences thread engagement point (bottom of thread).
GN
Table 8. Tubular Thermowell Ratings
Type
GN
GB
GN
NAMUR
Dimensions
9
⫻
1 mm
1.4571
(316 Ti)
11
⫻
2 mm
1.4571
(316 Ti)
12
⫻
2.5 mm
1.4571
(316 Ti)
Process connection
Screw Socket
G
1
/
2
Screw Socket
G1
Screw Socket
G1
Max. flow velocity
(m/s)
Air Water
25
40
40
3
5
5
Immersion length
(mm)
Max. pressure
(bar)
At 0 °C
250
400
160
220
280
160
250
400
160
50
18
100
100
100
50
40
18
100
At temperature (°C)
100 200 300 400
48
40
18
95
44
40
18
92
40
40
18
88
50
18
50
18
50
18
50
18
100 100 100 100
100 100 78 78
100 100 55 55
36
36
18
80 www.rosemount.com
33
Sensors and Accessories (Metric)
Figure 7. Barstock Thermowell Sensor Assemblies
644 with LCD Display Meter
644
Head or field mount transmitters
IP68 OR IP65,
Connection
Heads
40 mm
Sensor with flying leads, terminal block, or spring-loaded adapter
Stand-alone extensions
L
Weld-in, threaded, or flanged barstock thermowells
60 mm
T
U
U
★★
N dimension measures from thread engagement point.
★★★
This dimension is 80 mm for 1500# and 2500# flanges.
248
25 mm
3144
July 2015
11 mm
L
L
16 mm
11 mm
N
★★
60 mm
U
N
★★
N
★★
11 mm 11 mm
40 mm
60 mm
★★★
U
U
34 www.rosemount.com
July 2015
Sensors and Accessories (Metric)
Accessories
Table 9. Connection Head
Part number
Model/material
00644-4410-0011 Rosemount aluminum
00644-4410-0013 Rosemount aluminum
00644-4410-0021 Rosemount aluminum
00644-4410-0023 Rosemount aluminum
00644-4410-0111 Rosemount aluminum with LCD display cover
00644-4410-0113 Rosemount aluminum with LCD display cover
00644-4410-0121 Rosemount aluminum with LCD display cover
00644-4410-0123 Rosemount aluminum with LCD display cover
00644-4411-0011 Rosemount stainless steel
00644-4411-0013 Rosemount stainless steel
00644-4411-0021 Rosemount stainless steel
00644-4411-0023 Rosemount stainless steel
00644-4196-0023 GR–A/BL (BUZ), aluminum
00644-4197-0023 TZ–A/BL (BUZH), aluminum
66/68
66/68
66/68
66/68
66/68
66/68
65
65
66/68
66/68
66/68
66/68
66/68
66/68
IP rating Conduit connection
1
/
2
-in. NPT
1
/
2
-in. NPT
M20
⫻
1.5
M20
⫻
1.5
1
/
2
-in. NPT
1
/
2
-in. NPT
M20
⫻
1.5
M20
⫻
1.5
1
/
2
-in. NPT
1
/
2
-in. NPT
M20
⫻
1.5
M20
⫻
1.5
M20
⫻
1.5
M20
⫻
1.5
Process connection
1
/
2
-in. NPT
M24
⫻
1.5
1
/
2
-in. NPT
M24
⫻
1.5
1
/
2
-in. NPT
M24
⫻
1.5
1
/
2
-in. NPT
M24
⫻
1.5
1
/
2
-in. NPT
M24
⫻
1.5
1
/
2
-in. NPT
M24
⫻
1.5
M24
⫻
1.5
M24
⫻
1.5
Figure 8. Connection Head Dimensional Drawing
With LCD display cover
Option codes 1, 2
With standard cover
Option codes C, D, G, H
TZ-A/BL (BUZH)
Option code L
118
GR-A/BL (BUZ)
Option Code J
118
78
104
B 78
104
C
110
C
84
A
100
A
128
A
A. Head connection
B. LCD display
C. Cable entry
Dimensions are in millimeters.
www.rosemount.com
35
Sensors and Accessories (Metric)
Series 96 Barstock Thermowells
Figure 9. Flanged Barstock Thermowell – Tapered
T U
D
5.0
d
6.5
July 2015
Flange size
D d T
1-in. 150 – 1500 lbs, DN 25 19 12.5
60
1
1
/
2
to 2-in. 150 – 600 lbs, DN40 - 50 26.5
18 60
1.5 to 2-in. 900/1500 26.5
18 80
U. Immersion length
D. Stem diameter
T. Lagging length
Dimensions are in millimeters.
Note: Flanged thermowells generally conform to the specifications of ASME B 16.5 (ANSI) and DIN EN 1092-1.
Figure 10. Threaded Barstock Thermowell – Parallel Thread
5.0
6.5
40
D D1
U d
Parallel thread size
1
/
2
-in. BSPF (G
1
/
2
); M20
⫻
1.5
3
/
4
-in. BSPF (G
3
/
4
)
1-in. BSPF (G1)
M24
⫻
1.5
U. Immersion length
Dimensions are in millimeters.
D. Stem diameter
D D1 d
17
19
26
32
12.5
12.5
26.5
39
19 29
18
12.5
Figure 11. Threaded Barstock Thermowell – Tapered Thread
60 U
D d
6.5
Tapered thread size
1
/
2
-in. NPT; M20
⫻
1.5
3
/
4
-in. NPT
1-in. NPT
5.0
U. Immersion length
D. Stem diameter
Dimensions are in millimeters.
TL. Total length
T. Lagging length
D d
17 12.5
19 12.5
26.5
18
36 www.rosemount.com
July 2015
Figure 12. Weld-In Barstock Thermowell (Codes W10, W12, W14, W16)
60
S
D
T
U
5.0
U d
6.5
Socket size
3
/
4
-in.
1-in.
1
1
/
4
-in.
1
1
/
2
-in.
U. Immersion length
Dimensions are in millimeters.
D. Stem diameter
Sensors and Accessories (Metric)
S D
26.7
19.0
33.4
19.0
42.2
19.0
48.3
19.0
d
12.5
12.5
12.5
12.5
Figure 13. Weld-in Barstock Thermowell (codes E01, E02, E04, E05)
TL
24h7
T U
5.0
6.5
d
Previous DIN form
D1 D2 D4 D5 d
TL
U
T
140 200 200 260 12.5
65 125 65 125 12.5
75 75 135 135 12.5
U. Immersion length
TL. Total length
Dimensions are in millimeters.
T. Lagging length www.rosemount.com
37
Sensors and Accessories (Metric)
July 2015
Wake Frequency Calculation
Pressure and flow vibration
The strength of a thermowell depends on several parameters relating thermowell construction to the installation environment. For most industrial applications, standard Rosemount thermowells provide the necessary strength if the material, style, and length are correct for the application. The proper selection of a thermowell depends on fluid type, temperature, pressure, and fluid velocity.
Most thermowell failures are caused by vibration that is induced by fluid flow.
Emerson has a design system for the correct selection of thermowells. This selection service is available for a nominal charge, and to take advantage of this service, complete and return the Wake Frequency Calculation Configuration Data Sheet to your local Emerson
Process Management representative.
38 www.rosemount.com
July 2015
Sensors and Accessories (Metric)
www.rosemount.com
39
Sensors and Accessories (Metric)
00813-0200-2654, Rev KA
Global Headquarters
Emerson Process Management
6021 Innovation Blvd.
Shakopee, MN 55379, USA
+1 800 999 9307 or +1 952 906 8888
+1 952 949 7001
North America Regional Office
Emerson Process Management
8200 Market Blvd.
Chanhassen, MN 55317, USA
+1 800 999 9307 or +1 952 906 8888
+1 952 949 7001
Latin America Regional Office
Emerson Process Management
1300 Concord Terrace, Suite 400
Sunrise, Florida, 33323, USA
+1 954 846 5030
+1 954 846 5121
Europe Regional Office
Emerson Process Management Europe GmbH
Neuhofstrasse 19a P.O. Box 1046
CH 6340 Baar
Switzerland
+41 (0) 41 768 6111
+41 (0) 41 768 6300
Asia Pacific Regional Office
Emerson Process Management Asia Pacific Pte Ltd
1 Pandan Crescent
Singapore 128461
+65 6777 8211
+65 6777 0947
Middle East and Africa Regional Office
Emerson Process Management
Emerson FZE P.O. Box 17033,
Jebel Ali Free Zone - South 2
Dubai, United Arab Emirates
+971 4 8118100
+971 4 8865465
Product Data Sheet
July 2015
Standard Terms and Conditions of Sale can be found at: www.rosemount.com\terms_of_sale.
The Emerson logo is a trademark and service mark of Emerson Electric Co.
Rosemount and Rosemount logotype are registered trademarks of Rosemount Inc.
Complete Point Solutions is a trademark of Rosemount Inc.
NEMA is a registered trademark and service mark of the National Electrical
Manufacturers Association.
All other marks are the property of their respective owners.
©
2015 Rosemount Inc. All rights reserved.
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project