SEW-EURODRIVE MOVIPRO PHC11A-A040M1-P00K-01 Drive and control unit Operating Instructions

SEW-EURODRIVE MOVIPRO PHC11A-A040M1-P00K-01 Drive and control unit Operating Instructions
Add to My manuals

The MOVIPRO PHC11A-A040M1-P00K-01 is a decentralized field control for stationary use in industrial and commercial systems. Energy is supplied on the mains end (400 V~). The unit is designed as a gateway between the higher-level controller and the connected frequency inverters. The PHC11A unit is equipped with a processing unit that serves as a SEW field controller responsible for communication between the PHC11A and the higher-level controller. The unit is also equipped with a MOVIDRIVE® MCS20A-0040 drive inverter for controlling asynchronous motors and a brake control system for 24V disc brakes.

advertisement

Assistant Bot

Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.

SEW-EURODRIVE MOVIPRO PHC11A-A040M1-P00K-01 Operating Instructions | Manualzz

Gearmotors \ Industrial Gear Units \ Drive Electronics \ Drive Automation \ Services

MOVIPRO

®

PHC11A-A040M1-P00K-01

Edition 10/2006

11521813 / EN

O

perating

I

GC710000

nstructions

SEW-EURODRIVE – Driving the world

1 Important Notes...................................................................................................... 4

2 Safety Notes ........................................................................................................... 6

3 Unit Design ............................................................................................................. 8

3.1

Nameplate...................................................................................................... 8

3.2

Unit designation ............................................................................................. 9

3.3

Scope of delivery ......................................................................................... 10

3.4

Unit design ................................................................................................... 12

3.5

Operating principle ....................................................................................... 12

3.6

Power electronics......................................................................................... 13

3.7

Control technology ....................................................................................... 14

4 Installation ............................................................................................................ 15

4.1

Installation notes .......................................................................................... 15

4.2

Connections ................................................................................................. 21

4.3

Wiring diagrams ........................................................................................... 21

5 Startup................................................................................................................... 26

5.1

General notes .............................................................................................. 26

5.2

Motors and brakes ....................................................................................... 26

6 Operation and Service ......................................................................................... 27

6.1

Operating notes ........................................................................................... 27

6.2

Fault information .......................................................................................... 28

6.3

Shut down .................................................................................................... 30

6.4

Transportation ............................................................................................. 30

6.5

Storage ........................................................................................................ 30

6.6

Maintenance ................................................................................................ 30

7 Technical Data ...................................................................................................... 31

7.1

MOVIPRO

®

PHC11A ................................................................................... 31

7.2

Dimension drawing....................................................................................... 33

7.3

Additional information .................................................................................. 33

8 Index ...................................................................................................................... 34

Betriebsanleitung – MOVIPRO® PHC11A-A040M1-P00K-01

3

1

Important Notes

1

Operating Instructions

Important Notes

Safety and warning instructions

Always comply with the safety and warning instructions in this publication.

Hazard

Indicates an imminently hazardous situation which, if not avoided, WILL result in death or serious injury.

Warning

Indicates an imminently hazardous situation caused by the product which, if not avoided, WILL result in death or serious injury. This symbol also indicates potential for damage to property.

Caution

Indicates a potentially hazardous situation which, if not avoided, MAY result in minor injury or damage to products.

Note

Indicates a reference to useful information, e.g. on startup.

Documentation reference

Indicates a reference to a document, such as operating instructions, a catalog or a data sheet.

You must adhere to the operating instructions to ensure:

Fault-free operation

Fulfillment of any rights to claim under limited warranty

Therefore, read the operating instructions before you start operating the unit! The

operating instructions contain important information about service and should be kept near the unit.

4

Operating Instructions – MOVIPRO® PHC11A-A040M1-P00K-01

Important Notes

Designated use

MOVIPRO

®

PHC11A-A040M1-P00K-01 drive and control units are designed for stationary use in industrial and commercial systems for operating AC asynchronous motors with squirrel-cage rotors. These motors must be suitable for operation with frequency inverters. No other loads must be connected to the units.

In terms of power supply, the MOVIPRO

®

PHC11A-A040M1-P00K-01 drive and control units are designed for systems with direct supply that use pick-ups to draw power from a line cable. The components required for energy conversion are integrated in the unit.

Do not operate the unit until you have established that the machine complies with the

EMC Directive 89/336/EEC and that the conformity of the end product has been determined in accordance with the Machinery Directive 98/37/EEC (with reference to

EN 60204).

Observe all information on the technical data and the permitted conditions where the unit is operated. The rules and regulations of the Professional Association (Berufsgenossenschaft, BG), in particular BG rule B11 "Electromagnetic fields", must be observed during installation, startup and operation of systems with contactless energy transfer by induction for use in industrial workplaces.

Non-designated use

Customers are not permitted to remove covers or attempt to repair and set the

MOVIPRO

®

PHC11A-A040M1-P00K-01 drive and control unit themselves. Such actions are classified as non-designated use.

Only the manufacturing company is authorized to carry out repairs and make settings.

In case of malfunction, contact SEW-EURODRIVE GmbH & Co KG for information on how to proceed.

The manufacturer assumes no liability for operating the MOVIPRO

®

PHC11A-A040M1-

P00K-01 units in conditions other than those specified in these operating instructions.

Operational environment

The following uses are prohibited unless the units are expressly designed for the purpose:

• Use in potentially explosive areas.

• Use in areas exposed to harmful oils, acids, gases, vapors, dust, radiation, etc.

Waste disposal

Please follow the current national regulations.

Dispose of materials separately in accordance with the regulations in force, for example:

• Electronics scrap (circuit boards)

• Plastic (housing)

• Sheet metal

• Copper

• etc.

1

Operating Instructions – MOVIPRO® PHC11A-A040M1-P00K-01

5

2

Safety Notes

2 Safety Notes

Installation and startup

Never install damaged products or take them into operation. Submit a complaint to the transportation company immediately in the event of damage.

Installation, startup and service work may only be performed by trained

personnel observing applicable accident prevention regulations and operating instructions! The regulations in force (e.g. EN 60204, VBG 4, DIN-VDE

0100/0113/0160) must also be complied with. The following rules and regulations apply to the operator:

– Generally recognized safety rules.

– EC guidelines or other country-specific regulations

• Follow the specific instructions during installation and startup of the other components, such as motor and brake.

• Make sure that preventive measures and protection devices correspond to the

applicable regulations (e.g. EN 60204 or EN 50178).

Required preventive measures:

Systems with MOVITRANS

®

• Protective separation DIN VDE 0100-410, 1997

(IEC 60364-4-41, 2002)

• Low-impedance equipotential bonding on the machine frame

• ESD protection (for mobile components)

Systems with power supply module

• Grounding of the unit

The unit meets all requirements for safe disconnection of power and electronics connections in accordance with EN 61800. All connected circuits must also satisfy

the requirements for safe disconnection. If safe disconnection is required, the connected signal circuits have to meet the requirements according to SELV or PELV.

Operation and service

Before removing the protective cover, disconnect the unit from the supply

system. Dangerous voltage levels may still be present inside the unit and at the terminal strips up to 10 minutes after mains disconnection.

• When the protective cover is removed, the unit has enclosure IP00. Dangerous

voltages are present at all components except for the control electronics. The unit must be closed during operation.

When the unit switch is in the ON position, dangerous voltages are present at the output terminals as well as any connected cables and motor terminals. This also applies even when the unit is inhibited and the motor is at standstill.

• Just because the operation LED and other display elements have gone out does

not mean that the unit has been disconnected from the supply system and is de-

energized.

Internal safety functions or a mechanical blockage may cause the motor to

stop.

Removing the cause of the malfunction or performing a reset can cause the drive

to restart automatically.

As this is prohibited for the driven machine for safety reasons, disconnect the unit from the power supply before correcting the fault. In such cases, it is also forbidden for the "Auto Reset" (P841) to be activated.

6

Operating Instructions – MOVIPRO® PHC11A-A040M1-P00K-01

Safety Notes

Safety technology

• The inverter output may only be switched when the output stage is inhibited.

Switching the inverter output when the output stage is enabled leads to increased wear and will finally cause irreparable damage to the switch contacts. The switching equipment must be selected in accordance with the maximum DC voltage.

Warning of malfunctions

• The MOVIPRO

®

PHC11A-A040M1-P00K-01 drive and control units may not

execute any safety functions without higher-level safety systems unless expressly designed for this purpose. Malfunctions in the drive and control units of the

MOVIPRO

®

PHC11A-A040M1-P00K-01 product series can result in injuries to persons and damage to material and equipment.

Use higher-level safety systems to ensure protection of equipment and personnel!

Dangerous voltages!

• Do not connect or disconnect any plug connectors or interface connections when voltage is applied!

Mechanical protection

• The complete energy and control electronics is accommodated in a modular IP64

enclosure to provide protection against contact.

• The energy interfaces are designed using touch-safe plug connectors with IP65

protection (if locked).

• The connections for resolver and sensor/actuator boxes via M23 plug connector are designed in IP67 protection (when connected) .

• All M12 connections (sensors/actuators/diagnostic interfaces) are designed in

degree of protection IP67.

Electrical protection

Interfaces

ESD protection

Shielding

• All outgoing interfaces for energy supply (pick-up connections), motor connection and the 24 V voltage supply are designed in such a way (shape or color coded)

that they cannot be mixed up.

• The connectors of the resolver connection are color coded so that they cannot be

mixed up.

Sensor and actuator connections are designed with standardized M23 connectors so that they cannot be mixed up.

• A high-resistance discharge with a resistance of 1 to 100 M

is permitted for

ESD protection in the stationary system section.

Only use shielded control cables.

Connect the shield by the shortest possible route and make sure it is grounded

over a wide area at both ends. Ground one end of the shield via suppression capacitor (220 nF/50 V) to avoid ground loops.

If using double-shielded cables, ground the outer shield on the unit end and the inner shield on the other end.

2

Operating Instructions – MOVIPRO® PHC11A-A040M1-P00K-01

7

3

Unit Design

Nameplate

3 Unit Design

The following short name is used in this operating instruction.

Designation

MOVIPRO

®

PHC11A-A040M1-P00K-01 drive and control unit

Short name

PHC11A

3.1

Nameplate

Nameplate

Each unit has a nameplate that provides important information.

Figure 1: Nameplate of the PHC11A

U Voltage f Frequency

I Current

T Temperature

P Power

60181AXX

8

Operating Instructions – MOVIPRO® PHC11A-A040M1-P00K-01

Unit Design

Unit designation

3.2

Unit designation

The units of the MOVIPRO

®

product series have a unit designation that provides important information on the drive and control unit type:

P H C 1 1 A - A 040 M 1 - P 00 K - 01

Function level version:

01 = First function level

Function level:

K = Customer-specific

Protocol and version:

00 = No meaning

Communication medium:

P = ProfiBus

Number of motor connectors:

1 = 1 motor connector

Type of power connector:

M = Motor connector

Maximum S1 power:

040 = 4.0 kVA

Power input type:

A = AC

Version:

A = First generation

Depth of housing:

1 = 300 mm

Height of housing:

1 = 70 mm (without cooling fins)

Housing type:

C = Modular

Control type:

H = Drive control

Product family:

P = MOVIPRO

®

3

Operating Instructions – MOVIPRO® PHC11A-A040M1-P00K-01

9

3

Unit Design

Scope of delivery

3.3

Scope of delivery

Basic unit

The scope of delivery includes the PHC11A-A040M1-P00K-01 basic unit.

• PHC11A-A040M1-P00K-01 basic unit

Components

The PHC11A modular housing includes the following components:

• MOVIDRIVE

®

MCF20A0040 drive inverter

• Supply system rectifier for DC link conversion

• Brake control for 24 V brakes from SEW

• SEW field control with ProfiBus

• Connectors (without mating connectors) for

– 2 x sensors, actuators

– 1 x power supply connection

– 1 x RS232 service

– 1 x RS485 service

– 1 x motor connector

– 2 x braking resistor connection

– 2 x ProfiBus

10

Operating Instructions – MOVIPRO® PHC11A-A040M1-P00K-01

Unit Design

Scope of delivery

Part number

SEW-EURODRIVE identifies the units with the following part numbers:

Unit

MOVIPRO

®

PHC11A-A040M1-P00K-01 drive and control unit

Part number

13000438

Additional components

The scope of delivery does not include installation equipment, mounting accessories or connection cables.

If you have questions about which equipment/material to choose, please contact SEW-

EURODRIVE GmbH & Co KG.

Motor cables

We recommend the following cables for connecting PHC11A to the motor:

• With motor round connector (M23) / part number 1 172 494 3

3

• With ASB8 connector (HAN 10E) / part number 1 172 679 2

57744AXX

• With terminal box on motor / part number 1 172 242 8

58241AXX

Operating Instructions – MOVIPRO® PHC11A-A040M1-P00K-01

58242AXX

11

3

Unit Design

Unit design

3.4

Unit design

The following figure shows the unit design of PHC11A:

[4]

[1] [2]

Figure 2: PHC11A-A040M1-P00K-01 basic unit

[1]

[2]

[3]

[4]

T-slot profiles

Heat sink

Front panel connectors

Housing cover

[3]

60213AXX

3.5

Operating principle

Task

The PHC11A unit is designed as decentralized field control for stationary use in industrial and commercial systems. Energy is supplied on the mains end (400 V~).

Observe all information on the technical data and the permitted conditions where the unit is operated.

12

Operating Instructions – MOVIPRO® PHC11A-A040M1-P00K-01

Structure

Unit Design

Power electronics

The following block circuit diagram shows the connections of peripherals with

MOVIPRO

®

PHC11A:

3

RS232

ProfiBus In

ProfiBus Out

Dig. I/O 1

Dig. I/O 2

R485

M12

One-

Wire-

Modul

M23

M23

M12

RS232

I/O

ProfiBus

SEW Feldsteuerung

CPU

RS 485

SBus

FU

=

»

BGR

HAN Q8

HAN Q5 HAN Q8

M1

Bremswiderstand

Fahrantrieb M1

Figure 3: Block circuit diagram

Netzzuleitung

60179AXX

3.6

Power electronics

MOVIDRIVE

®

MCS20A-0040 drive inverter

The MOVIDRIVE

®

MCS20A-0040 drive inverter is not equipped with a fan. It is connected to the heat sink in cold-plate technology.

The supply voltage is DC 500 V. A 24 V switched-mode power supply with 4 A continuous output power is integrated, independent of the inverter electronics.

The MOVIDRIVE

®

drive inverter type MCS20A-0040 serves for controlling asynchronous motors.

Brake control system

Observe the information on the system properties and motor assignments in the

MOVIDRIVE

®

compact

system manual, part number 11493410/EN.

Brake control is responsible for the power supply and control of the 24 V disc brakes used in the motors connected to PHC11A.

In the PHC11A unit described in these operating instructions, brake control is installed internally. A brake rectifier type BMV 5 is used for the PHC11A unit.

When configuring the motors, note that if brake motors are used, an SEW brake coil must be fitted for each one. When selecting the SEW brake coil, note the permitted operating voltage for the brake coil.

The brake coil type is determined depending on the motor power.

Operating Instructions – MOVIPRO® PHC11A-A040M1-P00K-01

13

3

Unit Design

Control technology

3.7

Control technology

Processing unit

The PHC11A drive and control unit is equipped with a processing unit. This SEW field

controller is responsible for communication between PHC11A and the higher-level controller. It functions as a gateway between the higher-level controller and the connected frequency inverters.

For a detailed descriptiion of the interfaces and the gateway functionality, see the

"MOVIPRO

®

Interface Description" specification, part number 11471417/EN.

To connect the SEW field controller to a ProfiBus network, a suitable ProfiBus module is connected. The application software can easily be loaded to the processing unit via the ProfiBus interface or RS232 diagnostic interface.

14

Operating Instructions – MOVIPRO® PHC11A-A040M1-P00K-01

Installation

Installation notes

4 Installation

4.1

Installation notes

Minimum clearance

Cooling

Installation

Comply with the general safety notes during installation!

During installation, provide adequate space on the connection panel for the connection

cables in accordance with the dimension drawing. page 33.

Make sure that the heat sink segments can dissipate heat by means of free convection.

When attaching the unit to a mounting plate, the best dissipation properties can be achieved by:

• Using a mounting plate that is the same size as the unit itself

• Ensuring that the highest cooling fin is at least 25 mm away from the mounting plate

The unit is fitted with bends on the front end for mounting. These bends can be used to attach suitable mounting elements (e.g. T-slot nuts, screws with appropriate screw heads). The units can be installed in two ways:

• Version A: Screws are secured to the PHC housing from the back through the fastening elements.

• Version B: Screws are secured to the PHC housing from the front through the fastening element.

4

Operating Instructions – MOVIPRO® PHC11A-A040M1-P00K-01

15

4

Installation

Installation notes

The following figure shows the mounting hole positions:

[1]

[2]

[3]

25

[4] [5]

16

Mounting position

[A]

Figure 4: Installing the PHC11A

[1]

[2]

[3]

[4]

[5]

Corner profile with threaded hole (M8 x 20)

Fastening element

Housing cover

Tapped hole (M8 x 20)

Screws for mechanical connection

[B]

60214AXX

Use suitable supports or spacers to ensure optimum heat convection.

You must maintain a minimum distance of 25 mm from the highest cooling fin to the neighboring areas.

Maximum permitted tightening torque for the retaining screws: 3.2 Nm

The mounting position for units with cooling fins is vertical to allow for vertical air convection between the cooling fins.

Any other position is not permitted due to the reduced heat convection. Operation in a different mounting position can cause the unit to overheat, leading to irreparable damage.

Operating Instructions – MOVIPRO® PHC11A-A040M1-P00K-01

Installation

Installation notes

4

60215AXX

Figure 5: Permitted mounting positions for PHC11A

Always position the unit so that it will not collide with other components or design elements along the travel distance.

Dimensions of the T-slot profiles

When selecting the mounting elements, observe the dimensions of the angle profiles shown in the figure below.

R5,5

6

15

R7

15

Figure 6: Dimensions of the angle profiles

The dimensions of the PHC11A unit are shown in dimension drawing page 34.

57253AXX

Operating Instructions – MOVIPRO® PHC11A-A040M1-P00K-01

17

4

Installation

Installation notes

Shielding

Separate cable ducts

Unit output

Only use shielded motor and control cables.

Connect the shield by the shortest possible route and make sure it is grounded

over a wide area at both ends. Ground one end of the shield via suppression capacitor (220 nF/50 V) to avoid ground loops.

For cables with single shielding, apply the shielding to both ends.

For cables with double shielding (e. g. hybrid cable), apply the outer shielding to the MOVIPRO

®

and the inner shielding to the other end (e. g. motor).

Route power cables and electronics cables in separate cable ducts.

Connect only ohmic/inductive loads such as, for example, motors, at motor

connector -10X1. Never connect capacitive loads!

18

Digital inputs/digital outputs

60217AXX

Figure 7: Connection of inductive/ohmic loads at the motor connector

The motor supply cable must not exceed a maximum length of 15 m.

The digital inputs are electrically isolated by opto-couplers.

The digital outputs are electrically isolated by opto-couplers and are short-circuit

proof.

Grounding and equipotential bonding

Caution

Do not connect external brake rectifiers, for example in the motor terminal box.

ProfiBus IDmodule

Do not install or remove the ProfiBus ID-module when voltage is applied.

Switch off the unit before plugging in the ProfiBus ID-module.

Use two knurled screws to attach the ProfiBus ID-module. Tighten the knurled screws manually.

Maximum permitted tightening torque for the retaining screws: 0.2 Nm

Operating Instructions – MOVIPRO® PHC11A-A040M1-P00K-01

Installation

Installation notes

Position of the connection points

The connection points on the MOVIPRO

®

units for grounding or equipotential bonding are marked on the housing corners by a symbol.

Design

The holes for grounding are prepared for M5 self-tapping bolts, e.g. M5 x 12 to

DIN ISO 3506 or equivalent.

Proceed as follows to ground the unit:

1. First, place a terminal clip onto the ground bore, next the crimp cable lug for M5 and finally the tooth lock washer.

2. Tighten the elements using a self-tapping screw.

4

X

[1] [2]

[6] [5] [4] [3]

Figure 8: Grounding installation

[1]

[2]

[3]

[4]

[5]

[6]

Corner profile with M8 threaded hole

Housing bolts

Terminal clip

Crimp cable lug for M5

Tooth lock washer

Bolt, self-tapping

Operating Instructions – MOVIPRO® PHC11A-A040M1-P00K-01

X

60218AXX

19

4

Installation

Installation notes

Never loosen the connection screws at the housing corners.

Never secure the grounding or equipotential bonding cable using the housing

connection screws. They are tightened with a predefined tightenting torque at the factory. Once a housing connection screw is loosened, the sealing property and consequently degree of protection IP65 can no longer be ensured because the profiles have become distorted.

20

Operating Instructions – MOVIPRO® PHC11A-A040M1-P00K-01

Installation

Connections

4.2

Connections

The following sections describe the connections of PHC11A.

[1] [2] [3] [4] [5] [6] [7] [8] [9]

4

60216AXX

Figure 9: Connection assignment of PHC11A

[5]

[6]

[7]

[8]

[9]

[1]

[2]

[3]

[4]

-20x1

-20X2

-20X13

-20x14

-30X5

-10X13

-10X1

-10X5

-0X1

Connection for ProfiBus out (M12 5-pole, B-coded socket)

Connection for ProfiBus in (M12 5-pole, pins B-coded)

Connection for RS232 service (M12 5-pole, pins A-coded)

Connection for RS485 service (M12 5-pole, socket A-coded)

Connection for I/O field control (M23, 12-pole, socket 0°-coded)

Connection for I/O frequency inverter (M23 12-pole, socket 0°-coded)

Connection for motor connector (HAN Q8)

Connection for braking resistor (HAN Q5 socket)

Connection for supply system lead (HAN Q8 pins)

4.3

Wiring diagrams

Assignment -20X2: ProfiBus out, M12 B-coded (socket)

3 4

2 1

Figure 10: ProfiBus out, M12, 5-pole, B-coded (socket)

4

5

2

3

PIN

1

Assignment

+5 V

A

DGND

B

N.C.

Function

Supply voltage

Data line -

Reference potential

Data line +

60252AXX

Operating Instructions – MOVIPRO® PHC11A-A040M1-P00K-01

21

4

Installation

Wiring diagrams

Assignment -20x1: ProfiBus in, M12 B-coded (pins)

4 3

1 2

Figure 11: ProfiBus in , M12, 5-pole, B-coded (pins)

Function

4

5

2

3

PIN

1

Assignment

N.C.

A

N.C.

B

N.C.

Data line -

Data line +

Assignment -20X14: RS485 – connection for RS485 interface, M12 A-coded (socket)

3 4

2 1

Figure 12: Connection for RS485 interface – M12, 5-pole, A-coded (socket)

4

5

2

3

PIN

1

Assignment

VO24V

RS485-

0V24

RS485+

N.C.

Function

24 V supply voltage

RS-

Reference potential 24V

RS+

Assignment -20x13: RS232 service, M12 A-coded (socket)

3 4

2 1

Figure 13: RS232 service, M12, 5-pole, A-coded (socket)

4

5

2

3

PIN

1

Assignment

VO24V

TxD

0V24

RxD

N.C.

Function

24 V voltage supply

RS-

Reference potential

RS-

60251AXX

60254AXX

60254AXX

22

Operating Instructions – MOVIPRO® PHC11A-A040M1-P00K-01

Installation

Wiring diagrams

Assignment -10X1: Motor connection, HAN Q8 (socket)

2

3

5

8

1

4

PE

6

7

Figure 14: Motor connection, 5-pole, HAN Q8 (socket)

Terminal

-10X1.1

-10X1.2

-10X1.3

-10X1.4

-10X1.5

-10X1.6

-10X1.7

-10X1.8

-10X1.PE

Assignment

U

BG 0.14

W

BG 0.15

FU Ref 10V+

BG .13

V

FU AI21

Weight

Function

Motor connection phase U

Brake with high-speed excitation

Motor connection phase W

0V24 brake

TF+/TH+

Brake +24 V

Motor connection phase V

TF-/TH-

Equipotential bonding

Assignment -10X9: Braking resistor, HAN Q5 (socket)

57664AXX

4

PE

1

3

4

2

5

Figure 15: Braking resistor, 5-pole, HAN Q5 (socket)

Function Terminal

-10X9.1

-10X9.2

-10X9.3

-10X9.4

-10X9.5

-10X9.PE

Assignment

N.C.

N.C.

R+

N.C.

R-

Weight

Braking resistor +

Braking resistor -

Equipotential bonding

58255AXX

Operating Instructions – MOVIPRO® PHC11A-A040M1-P00K-01

23

4

Installation

Wiring diagrams

Assignment -10X13: Digital inputs and outputs, M23 0°-coded, (socket)

1 9 8

2

3

10

12

4

11

5

6

7

Figure 16: Digital inputs and outputs, M23, 12-pole, 0°-coded (socket)

Terminal

-30X5.1

-30X5.2

-30X5.3

-30X5.4

-30X5.5

-30X5.6

-30X5.7

-30X5.8

-30X5.9

-30X5.10

-30X5.11

-30X5.12

Assignment

DI00

DI01

DI02

DI03

DI04

DI05

DO00

DO01

0V24

0V24

+24V

Weight

Function

Digital input frequency inverter

Digital input frequency inverter

Digital input frequency inverter

Digital input frequency inverter

Digital input frequency inverter

Digital input frequency inverter

Digital output frequency inverter

Digital output frequency inverter

Reference potential

Reference potential

24 V supply voltage

Equipotential bonding

58256AXX

24

Operating Instructions – MOVIPRO® PHC11A-A040M1-P00K-01

Installation

Wiring diagrams

Assignment -30X5: Digital inputs and outputs, M23 0°-coded (socket)

1 9 8

2

3

10 12

4

11

5

6

7

Figure 17: Digital inputs and outputs, M23, 12-pole, 0°-coded (socket)

Terminal

-30X5.1

-30X5.2

-30X5.3

-30X5.4

-30X5.5

-30X5.6

-30X5.7

-30X5.8

-30X5.9

-30X5.10

-30X5.11

-30X5.12

Assignment

DI00

DI01

DI02

DI03

DI04

DI05

DO00

DO01

0V24

0V24

+24V

Weight

Function

Digital input of field controller

Digital input of field controller

Digital input of field controller

Digital input of field controller

Digital input of field controller

Digital input of field controller

Digital output of field controller

Digital output of field controller

Reference potential

Reference potential

24 V supply voltage

Equipotential bonding

58256AXX

4

Operating Instructions – MOVIPRO® PHC11A-A040M1-P00K-01

25

5

I

Startup

General notes

5 Startup

5.1

General notes

It is essential to comply with the safety notes in section 2 during startup!

Prerequisites for startup

The following prerequisites must be met for these steps:

• PHC11A must be connected in accordance with the instructions in the Installation section.

• The system and connected drives must be configured correctly. You can configure the PHC11A using the MOVITOOLS

®

and MOVIVISION

®

software.

• PHC11A must be supplied with voltage.

Important

• Potentially fatal voltages may occur if the unit is connected incorrectly. Ensure that the unit is connected as specified.

• Appropriate safety measures must be taken to prevent the motor from starting unintentionally.

• Moreover, additional safety precautions must be taken to avoid injury to persons and damage to machinery.

• Comply with the safety notes during startup.

• When the status display goes out, this does not mean that the unit has been disconnected.

5.2

Motors and brakes

Motors

Brakes

For U/f operation of PHC11A, only the following SEW standard motors in star and delta connection are permitted:

• DV motors

Only brakes with a coil voltage of 24 V are permitted. All other brakes may destroy the

PHC11A.

26

Operating Instructions – MOVIPRO® PHC11A-A040M1-P00K-01

Operation and Service

Operating notes

6 Operation and Service

6.1

Operating notes

Duty types

The following operating modes are determined according to ED information (information on the cyclic duration factor) EN 60034-1 on ambient temperature

ϑ

U

0 °C... +40 °C at

I

D

= 100 % I additional32

N

and f

PWM

= 4 kHz, cyclic duration factor 50 % cdf, T = 1 h; each

degree Celsius in temperature results in a decreased cdf of 4 %.

Operating mode

S1

S2

S3

S4...S10

Explanation

Continuous duty: Operation at a constant load; the motor reaches thermal equilibrium.

Short-time duty: Operation at constant load for a given time followed by a time at rest.

The motor returns to ambient temperature during the rest period.

Intermittent periodic duty: The starting current does not significantly affect the temperature rise. Characterized by a sequence of identical duty cycles, each including a time of operation at constant load and a time at rest. Described by the "cyclic duration factor

(cdf)" in %.

Intermittent periodic duty: The starting current affecting the temperature rise. Characterized by a sequence of identical duty cycles, each including a time of operation at constant load and a time at rest. Described by the "cyclic duration factor (cdf)" in % and the number of cycles per hour.

6

ma x ma x ma x

Cyclic duration factor (cdf)

03135AXX

Figure 18: Duty types S1, S2 and S3

The cyclic duration factor (cdf) is the ratio between the period of loading and the duration of the duty cycle. The duration of the duty cycle is the sum of times of operation and times at rest and de-energized. A typical value for the duration of the duty cycle is ten minutes.

CDF = sum of times of operation (t1 + t2 + t3) duty cycle duration (T)

• 100 [%]

Operating Instructions – MOVIPRO® PHC11A-A040M1-P00K-01

27

6

Operation and Service

Fault information

Important:

• When the unit is switched on, dangerous voltages are present at the output terminals as well as any connected cables and motor terminals. This also applies even if the

unit is inhibited and the motor is at standstill.

• Do not change the switch under load.

• Disconnect the unit from voltage supply before performing work on the unit.

Dangerous voltages may still be present for up to ten minutes after disconnection from the power supply source.

• The unit output may only be switched when the output stage of the inverter is

inhibited.

6.2

Fault information

Fault memory

Only the manufacturing company is authorized to carry out repairs.

In case of malfunction, contact SEW-EURODRIVE GmbH & Co KG for information on how to proceed.

The error memory (P080) stores the last five error messages (errors t-0 to t-4). The error message of longest standing is deleted whenever more than five error messages have occurred. The following information is stored when a malfunction occurs:

• Error which has occurred

• Status of binary inputs/outputs

• Operating status of the inverter

• Inverter status

• Heat sink temperature

• Speed

• Output current

• Active current

• Unit utilization

• DC link voltage

• Hours of operation

• Enable hours

• Parameter set

• Motor utilization

28

Operating Instructions – MOVIPRO® PHC11A-A040M1-P00K-01

Operation and Service

Fault information

Switch-off responses

Immediate stop

Rapid stop

Emergency stop

Reset

There are three switch-off responses depending on the error. The inverter remains inhibited in fault status:

The unit can no longer brake the drive; the output stage goes to high resistance in the event of a fault and the brake is applied immediately (DBØØ "/Brake" = "0").

The drive is braked with the stop ramp t13/t23. The brake is applied once the stop speed is reached (DBØØ "/Brake" = "0"). The output stage goes to high resistance after the brake reaction time has elapsed (P732 / P735).

The drive is braked with the emergency ramp t14/t24. The brake is applied once the stop speed is reached (DBØØ "/Brake" = "0"). The output stage goes to high resistance after the brake reaction time has elapsed (P732 / P735).

An error message can be acknowledged by:

• Switching the voltage supply on and off

Recommendation: Adhere to a minimum switch-off time of 10 s.

• Reset with parameter 840 = "YES" or [Parameter] / [Manual reset].

• Auto reset performs up to five unit resets with an adjustable restart time.

Do not use auto-reset with drives where an automatic restart could represent a danger to people or units.

Timeout active

If the inverter is controlled via a communication interface (fieldbus, RS485 or SBus) and the power was switched off and back on again or a fault reset was performed, then the enable remains ineffective until the inverter receives valid data again via the interface, which is monitored with a timeout.

6

Operating Instructions – MOVIPRO® PHC11A-A040M1-P00K-01

29

6

Operation and Service

Shut down

6.3

Shut down

To shut down PHC11A, disconnect the unit using appropriate measures.

Important:

Dangerous voltages may still be present at the terminals and connections for up to ten minutes after switching off the PHC11A.

6.4

Transportation

Observe the following instructions when transporting the PHC11A unit:

• Cover the connections with the supplied protective caps before transportation.

• Pace the unit on the heat sink or on the side without connectors during transportation.

• Make sure that the unit is not subject to mechanical impact during transport.

6.5

Storage

Observe the following instructions when storing the PHC11A unit:

• If you shut down and store the unit for a longer period, you must cover the connections with the protective caps supplied.

• Only store the unit on the heat sink or on the side without connectors during transportation.

• Make sure that the unit is not subject to mechanical impact during storage.

6.6

Maintenance

PHC11A does not require any maintenance. The manufacturer does not stipulate any inspection work that has to be performed regularly.

30

Operating Instructions – MOVIPRO® PHC11A-A040M1-P00K-01

Technical Data

MOVIPRO® PHC11A

kVA f i

P Hz n

7 Technical Data

7.1

MOVIPRO

®

PHC11A

The following tables list the technical data for PHC11A.

General data

Feature

Interference immunity

Ambient temperature

Derating ambient temperature

Climate class

Storage temperature

Enclosure

Weight

Dimensions W x H x D

Size

ϑ

U

ϑ

L

Data

meets EN 61800-3 (in preparation)

-5 °C ... +40 °C

(Non-condensing, no moisture condensation)

P

N

reduction: 3 % I

N

per K to max. 60 °C

When the temperature of the heat sink increases to more than 80°C, the device switches off and the fault message "Overtemperature" is generated.

EN 60721-3-3

Class 3K3

-25 °C ... +70 °C (EN 60721-3-3, class 3K3)

IP65

11 kg

420 x 300 x 110 mm (connector not taken into account)

General data for power section

Feature

Operating mode

Overall rated output power

Rated current

Data for power section input

Feature

Operating voltage

Rated input current

Size

ϑ

L

P

N

I

N

Size

U

E

I pick-up

Data

continuous duty (EN 60149-1-1 and 1-3)

9.5 A

AC

Data

380 V

AC

- 10 % ... 500 V

AC

+ 10 %

8.6 A

AC

7

The overall rated power depends on the connected load. The total rated power is decisive for the maximum output power of the unit. The power data of the individual axes may deviate from these values.

Operating Instructions – MOVIPRO® PHC11A-A040M1-P00K-01

31

7

kVA f i

P Hz n

Technical Data

MOVIPRO® PHC11A

DDate output power section axis - 10x1

Feature

Operating mode

Rated output power

Rated output current

Current limitation

Output voltage

PWM frequency

Speed range / resolution

Size

ϑ

L

P

N

I

N

I max

U

A f

PWM n

/ n

A

Maximum motor cable length

Constant load S1

Recommended motor power

P

Mot

P

Mot

Data

continuous duty (EN 60149-1-1 and 1-3)

4 kW

9.5 A

AC motor and regenerative 150 % I

N

0..0.500 V

AC

Can be set: 4/8/16 kHz (P860/P861)

-5000 ... 0 ... +5000 min

-1

/ 0.2 min

-1 across the entire range

15 m

4 kW (5.3 HP)

24 V voltage supply

Feature

24 V sensor power supply VO24_DIO

(sensors/actuators)

24 V voltage supply VO24

(communication interfaces / bus)

24 V emergency stop relays

Data

Output voltage 24 V -/-5 %

Total output current limited to at least 500 mA

Short circuit and overload protection

Not interference-voltage-proof

Output voltage 24 V -/-5 %

Total output current limited to at least 500 mA

Short circuit and overload protection

Not interference-voltage-proof

Output voltage 24 V -/-5 %

Total output current limited to at least 3.5 A

Short circuit and overload protection

Not interference-voltage-proof

Digital inputs and outputs

Feature

Digital inputs

Digital outputs

Data

PLC compatible according to EN 61131-2 R i f g

LOW"

3 k

2.8 kHz 15 V...30 V input "HIGH" -3 V...5 V input"

PLC compatible according to EN 61131-2 I

OUT

=

500 mA (per output) output "HIGH" 24 V +/- 5% output

"LOW" 0 V +5%

Short circuit and overload protection

Not interference-voltage-proof

32

Operating Instructions – MOVIPRO® PHC11A-A040M1-P00K-01

Technical Data

Dimension drawing

kVA f i

P Hz n

7.2

Dimension drawing

PHC11A-A040M1-

P00K-01

The dimension drawing shows the mechanical dimensions of PHC11A:

7

Standards and certifications

6.5 / M8x20

[A]

390

420

Figure 19: Dimension drawing for PHC11A, dimensions in mm

7.3

Additional information

Publications

For further information, refer to the following documentation:

Documentation

MOVIDRIVE

®

MCF/MCV/MCS20A operating instructions

MOVIDRIVE

® compact MCF/MCV/MCS20A operating instructions

MOVIDRIVE

®

compact system manual

60219AXX

Publication number

11282916/EN

10556214/EN

11533811/EN

The PHC11A drive and control unit was developed and tested based on the following standards:

• VDE 0100

• EN 954

• EN 61800

Operating Instructions – MOVIPRO® PHC11A-A040M1-P00K-01

33

8

Index

34

8 Index

A

Accessories

.........................................................11

Additional information

.........................................33

Publications

..................................................33

Standards and certifications

.........................33

B

Basic units

...........................................................10

Block circuit diagram

...........................................13

Brakes

.................................................................26

C

Cable ducts

.........................................................18

Components

........................................................10

Connections

................................................. 13

,

21

Control technology

..............................................14

Cooling

................................................................15

Cyclic duration factor

..........................................27

D

Designated use

.....................................................5

Digital inputs

.......................................................18

Digital outputs

.....................................................18

Dimension drawing

.............................................33

Dimensions

.........................................................33

E

equipotential bonding

..........................................19

Error memory

......................................................28

F

Fault information

.................................................28

G

Grounding

.................................................... 18

,

19

I

Installation

...........................................................15

Installation notes

.................................................15

Integrated components

SEW field controller

......................................14

M

Maintenance

.......................................................30

Minimum clearance

.............................................15

Motor cables

.......................................................11

Motors

.................................................................26

Mounting

.............................................................15

Mounting position

................................................16

N

Nameplate

.............................................................8

Non-designated use

..............................................5

O

Operating modes

................................................27

Operating notes

.................................................. 27

Operating principle

............................................. 12

Operational environment

...................................... 5

P

Part number

....................................................... 11

Power electronics

............................................... 13

ProfiBus ID-module

............................................ 18

Protective measures

............................................ 6

Publications

........................................................ 33

R

Reset

.................................................................. 29

S

Safety Notes

......................................................... 6

Safety notes

Installation and startup

................................... 6

Operation and service

.................................... 6

Safety requirements

Electrical protection

....................................... 7

ESD protection

............................................... 7

Interfaces

....................................................... 7

Mechanical protection

.................................... 7

Shielding

........................................................ 7

Scope of delivery

................................................ 10

SEW field controller

............................................ 14

Shielding

............................................................ 18

Short name

........................................................... 8

Shut down

.......................................................... 30

Standards

........................................................... 33

Standards and certifications

............................... 33

Startup

Procedure

.................................................... 26

Storage

............................................................... 30

Structure

............................................................. 13

Switch-off response to faults

.............................. 29

T

Technical data

Data power section output

........................... 32

Digital inputs and outputs

............................ 32

General information

..................................... 31

General power section

................................. 31

Power section input

..................................... 31

24 V voltage supply

..................................... 32

Timeout active

.................................................... 29

Transportation

.................................................... 30

T-slot profiles

Dimensions

.................................................. 17

Operating Instructions – MOVIPRO® PHC11A-A040M1-P00K-01

Index

U

Unit design

............................................................8

Unit output

...........................................................18

Use

designated

......................................................5

W

warning instructions

..............................................4

Waste disposal

......................................................5

Wiring diagrams

................................................. 21

Braking resistor

............................................ 23

Connection for RS485 interface

................... 22

Digital inputs/outputs

............................. 24

,

25

Motor connection

......................................... 23

ProfiBus In

................................................... 22

ProfiBus Out

................................................ 21

RS232 service

............................................. 22

8

Operating Instructions – MOVIPRO® PHC11A-A040M1-P00K-01

35

36

Address List

Address List

Germany

Headquarters

Production

Sales

Service

Competence Center

Bruchsal

Central

Gear units /

Motors

Central

Electronics

SEW-EURODRIVE GmbH & Co KG

Ernst-Blickle-Straße 42

D-76646 Bruchsal

P.O. Box

Postfach 3023 • D-76642 Bruchsal

SEW-EURODRIVE GmbH & Co KG

Ernst-Blickle-Straße 1

D-76676 Graben-Neudorf

SEW-EURODRIVE GmbH & Co KG

Ernst-Blickle-Straße 42

D-76646 Bruchsal

North

East

SEW-EURODRIVE GmbH & Co KG

Alte Ricklinger Straße 40-42

D-30823 Garbsen (near Hannover)

SEW-EURODRIVE GmbH & Co KG

Dänkritzer Weg 1

D-08393 Meerane (near Zwickau)

South

West

SEW-EURODRIVE GmbH & Co KG

Domagkstraße 5

D-85551 Kirchheim (near München)

SEW-EURODRIVE GmbH & Co KG

Siemensstraße 1

D-40764 Langenfeld (near Düsseldorf)

Drive Service Hotline / 24 Hour Service

Additional addresses for service in Germany provided on request!

Tel. +49 7251 75-0

Fax +49 7251 75-1970 http://www.sew-eurodrive.de

[email protected]

Tel. +49 7251 75-1710

Fax +49 7251 75-1711 [email protected]

Tel. +49 7251 75-1780

Fax +49 7251 75-1769 [email protected]

Tel. +49 5137 8798-30

Fax +49 5137 8798-55 [email protected]

Tel. +49 3764 7606-0

Fax +49 3764 7606-30 [email protected]

Tel. +49 89 909552-10

Fax +49 89 909552-50 [email protected]

Tel. +49 2173 8507-30

Fax +49 2173 8507-55 [email protected]

+49 180 5 SEWHELP

+49 180 5 7394357

France

Production

Sales

Service

Assembly

Sales

Service

Haguenau

Bordeaux

SEW-USOCOME

48-54, route de Soufflenheim

B. P. 20185

F-67506 Haguenau Cedex

SEW-USOCOME

Parc d'activités de Magellan

62, avenue de Magellan - B. P. 182

F-33607 Pessac Cedex

Lyon

Paris

SEW-USOCOME

Parc d'Affaires Roosevelt

Rue Jacques Tati

F-69120 Vaulx en Velin

SEW-USOCOME

Zone industrielle

2, rue Denis Papin

F-77390 Verneuil I'Etang

Additional addresses for service in France provided on request!

Tel. +33 3 88 73 67 00

Fax +33 3 88 73 66 00 http://www.usocome.com

[email protected]

Tel. +33 5 57 26 39 00

Fax +33 5 57 26 39 09

Tel. +33 4 72 15 37 00

Fax +33 4 72 15 37 15

Tel. +33 1 64 42 40 80

Fax +33 1 64 42 40 88

Algeria

Sales Alger

Réducom

16, rue des Frères Zaghnoun

Bellevue El-Harrach

16200 Alger

Tel. +213 21 8222-84

Fax +213 21 8222-84

Argentina

Assembly

Sales

Service

Buenos Aires

SEW EURODRIVE ARGENTINA S.A.

Centro Industrial Garin, Lote 35

Ruta Panamericana Km 37,5

1619 Garin

Tel. +54 3327 4572-84

Fax +54 3327 4572-21 [email protected]

Address List

Australia

Assembly

Sales

Service

Austria

Assembly

Sales

Service

Belgium

Assembly

Sales

Service

Brazil

Production

Sales

Service

Bulgaria

Sales

Cameroon

Sales

Canada

Assembly

Sales

Service

Chile

Assembly

Sales

Service

Melbourne

Sydney

Townsville

Wien

Brüssel

SEW-EURODRIVE PTY. LTD.

27 Beverage Drive

Tullamarine, Victoria 3043

SEW-EURODRIVE PTY. LTD.

9, Sleigh Place, Wetherill Park

New South Wales, 2164

SEW-EURODRIVE PTY. LTD.

12 Leyland Street

Garbutt, QLD 4814

SEW-EURODRIVE Ges.m.b.H.

Richard-Strauss-Strasse 24

A-1230 Wien

SEW Caron-Vector S.A.

Avenue Eiffel 5

B-1300 Wavre

Tel. +61 3 9933-1000

Fax +61 3 9933-1003 http://www.sew-eurodrive.com.au

[email protected]

Tel. +61 2 9725-9900

Fax +61 2 9725-9905 [email protected]

Tel. +61 7 4779 4333

Fax +61 7 4779 5333 [email protected]

Tel. +43 1 617 55 00-0

Fax +43 1 617 55 00-30 http://sew-eurodrive.at

[email protected]

Tel. +32 10 231-311

Fax +32 10 231-336 http://www.caron-vector.be

[email protected]

Tel. +55 11 6489-9133

Fax +55 11 6480-3328 http://www.sew.com.br

[email protected]

Sao Paulo

SEW-EURODRIVE Brasil Ltda.

Avenida Amâncio Gaiolli, 50

Caixa Postal: 201-07111-970

Guarulhos/SP - Cep.: 07251-250

Additional addresses for service in Brazil provided on request!

Sofia

Douala

BEVER-DRIVE GmbH

Bogdanovetz Str.1

BG-1606 Sofia

Electro-Services

Rue Drouot Akwa

B.P. 2024

Douala

Tel. +359 2 9151160

Fax +359 2 9151166 [email protected]

Tel. +237 4322-99

Fax +237 4277-03

Toronto

SEW-EURODRIVE CO. OF CANADA LTD.

210 Walker Drive

Bramalea, Ontario L6T3W1

Vancouver

Montreal

SEW-EURODRIVE CO. OF CANADA LTD.

7188 Honeyman Street

Delta. B.C. V4G 1 E2

SEW-EURODRIVE CO. OF CANADA LTD.

2555 Rue Leger Street

LaSalle, Quebec H8N 2V9

Additional addresses for service in Canada provided on request!

Tel. +1 905 791-1553

Fax +1 905 791-2999 http://www.sew-eurodrive.ca

[email protected]

Tel. +1 604 946-5535

Fax +1 604 946-2513 [email protected]

Tel. +1 514 367-1124

Fax +1 514 367-3677 [email protected]

Santiago de

Chile

SEW-EURODRIVE CHILE LTDA.

Las Encinas 1295

Parque Industrial Valle Grande

LAMPA

RCH-Santiago de Chile

P.O. Box

Casilla 23 Correo Quilicura - Santiago - Chile

Tel. +56 2 75770-00

Fax +56 2 75770-01 www.sew-eurodrive.cl

[email protected]

37

38

Address List

China

Production

Assembly

Sales

Service

Assembly

Sales

Service

Tianjin

SEW-EURODRIVE (Tianjin) Co., Ltd.

No. 46, 7th Avenue, TEDA

Tianjin 300457

Suzhou

SEW-EURODRIVE (Suzhou) Co., Ltd.

333, Suhong Middle Road

Suzhou Industrial Park

Jiangsu Province, 215021

P. R. China

Additional addresses for service in China provided on request!

Colombia

Assembly

Sales

Service

Croatia

Sales

Service

Czech Republic

Sales

Bogotá

Zagreb

Praha

SEW-EURODRIVE COLOMBIA LTDA.

Calle 22 No. 132-60

Bodega 6, Manzana B

Santafé de Bogotá

KOMPEKS d. o. o.

PIT Erdödy 4 II

HR 10 000 Zagreb

SEW-EURODRIVE CZ S.R.O.

Business Centrum Praha

Luzna 591

CZ-16000 Praha 6 - Vokovice

Denmark

Assembly

Sales

Service

Estonia

Sales

Kopenhagen

Tallin

SEW-EURODRIVEA/S

Geminivej 28-30, P.O. Box 100

DK-2670 Greve

ALAS-KUUL AS

Mustamäe tee 24

EE-10620Tallin

Finland

Assembly

Sales

Service

Gabon

Sales

Lahti

Libreville

SEW-EURODRIVE OY

Vesimäentie 4

FIN-15860 Hollola 2

Electro-Services

B.P. 1889

Libreville

Great Britain

Assembly

Sales

Service

Greece

Sales

Service

Normanton

Athen

SEW-EURODRIVE Ltd.

Beckbridge Industrial Estate

P.O. Box No.1

GB-Normanton, West- Yorkshire WF6 1QR

Christ. Boznos & Son S.A.

12, Mavromichali Street

P.O. Box 80136, GR-18545 Piraeus

Tel. +86 22 25322612

Fax +86 22 25322611 [email protected]

http://www.sew-eurodrive.com.cn

Tel. +86 512 62581781

Fax +86 512 62581783 [email protected]

Tel. +57 1 54750-50

Fax +57 1 54750-44 http://www.sew-eurodrive.com.co

[email protected]

Tel. +385 1 4613-158

Fax +385 1 4613-158 [email protected]

Tel. +420 220121234

Fax +420 220121237 http://www.sew-eurodrive.cz

[email protected]

Tel. +45 43 9585-00

Fax +45 43 9585-09 http://www.sew-eurodrive.dk

[email protected]

Tel. +372 6593230

Fax +372 6593231 [email protected]

Tel. +358 201 589-300

Fax +358 3 780-6211 [email protected]

http://www.sew-eurodrive.fi

Tel. +241 7340-11

Fax +241 7340-12

Tel. +44 1924 893-855

Fax +44 1924 893-702 http://www.sew-eurodrive.co.uk

[email protected]

Tel. +30 2 1042 251-34

Fax +30 2 1042 251-59 http://www.boznos.gr

[email protected]

Address List

Japan

Assembly

Sales

Service

Korea

Assembly

Sales

Service

Latvia

Sales

Hong Kong

Assembly

Sales

Service

Hungary

Sales

Service

Ireland

Sales

Service

Israel

Sales

Italy

Assembly

Sales

Service

Ivory Coast

Sales

Hong Kong

Budapest

India

Assembly

Sales

Service

Technical Offices

Baroda

Bangalore

Dublin

Tel-Aviv

Milano

Abidjan

Toyoda-cho

Ansan-City

Riga

SEW-EURODRIVE LTD.

Unit No. 801-806, 8th Floor

Hong Leong Industrial Complex

No. 4, Wang Kwong Road

Kowloon, Hong Kong

SEW-EURODRIVE Kft.

H-1037 Budapest

Kunigunda u. 18

SEW-EURODRIVE India Pvt. Ltd.

Plot No. 4, Gidc

Por Ramangamdi • Baroda - 391 243

Gujarat

SEW-EURODRIVE India Private Limited

308, Prestige Centre Point

7, Edward Road

Bangalore

Tel. +852 2 7960477 + 79604654

Fax +852 2 7959129 [email protected]

Tel. +36 1 437 06-58

Fax +36 1 437 06-50 [email protected]

Tel. +91 265 2831086

Fax +91 265 2831087 http://www.seweurodriveindia.com

[email protected]

Tel. +91 80 22266565

Fax +91 80 22266569 [email protected]

Alperton Engineering Ltd.

48 Moyle Road

Dublin Industrial Estate

Glasnevin, Dublin 11

Liraz Handasa Ltd.

Ahofer Str 34B / 228

58858 Holon

Tel. +353 1 830-6277

Fax +353 1 830-6458

Tel. +972 3 5599511

Fax +972 3 5599512 [email protected]

SEW-EURODRIVE di R. Blickle & Co.s.a.s.

Via Bernini,14

I-20020 Solaro (Milano)

Tel. +39 02 96 9801

Fax +39 02 96 799781 http://www.sew-eurodrive.it

[email protected]

SICA

Ste industrielle et commerciale pour l'Afrique

165, Bld de Marseille

B.P. 2323, Abidjan 08

Tel. +225 2579-44

Fax +225 2584-36

Tel. +81 538 373811

Fax +81 538 373814 [email protected]

SEW-EURODRIVE JAPAN CO., LTD

250-1, Shimoman-no,

Iwata

Shizuoka 438-0818

SEW-EURODRIVE KOREA CO., LTD.

B 601-4, Banweol Industrial Estate

Unit 1048-4, Shingil-Dong

Ansan 425-120

SIA Alas-Kuul

Katlakalna 11C

LV-1073 Riga

Tel. +82 31 492-8051

Fax +82 31 492-8056 http://www.sew-korea.co.kr

[email protected]

Tel. +371 7139253

Fax +371 7139386 http://www.alas-kuul.com

[email protected]

39

40

Address List

Lebanon

Sales

Lithuania

Sales

Luxembourg

Assembly

Sales

Service

Malaysia

Assembly

Sales

Service

Mexico

Assembly

Sales

Service

Morocco

Sales

Netherlands

Assembly

Sales

Service

New Zealand

Assembly

Sales

Service

Norway

Assembly

Sales

Service

Peru

Assembly

Sales

Service

Beirut

Alytus

Brüssel

Gabriel Acar & Fils sarl

B. P. 80484

Bourj Hammoud, Beirut

UAB Irseva

Naujoji 19

LT-62175 Alytus

CARON-VECTOR S.A.

Avenue Eiffel 5

B-1300 Wavre

Tel. +961 1 4947-86

+961 1 4982-72

+961 3 2745-39

Fax +961 1 4949-71 [email protected]

Tel. +370 315 79204

Fax +370 315 56175 [email protected]

http://www.sew-eurodrive.lt

Tel. +32 10 231-311

Fax +32 10 231-336 http://www.caron-vector.be

[email protected]

Johore

Queretaro

Casablanca

SEW-EURODRIVE SDN BHD

No. 95, Jalan Seroja 39, Taman Johor Jaya

81000 Johor Bahru, Johor

West Malaysia

Tel. +60 7 3549409

Fax +60 7 3541404 [email protected]

SEW-EURODRIVE MEXIKO SA DE CV

SEM-981118-M93

Tequisquiapan No. 102

Parque Industrail Queretaro

C.P. 76220

Queretaro, Mexico

Afit

5, rue Emir Abdelkader

MA 20300 Casablanca

Tel. +52 442 1030-300

Fax +52 442 1030-301 http://www.sew-eurodrive.com.mx

[email protected]

Tel. +212 22618372

Fax +212 22618351 [email protected]

Tel. +31 10 4463-700

Fax +31 10 4155-552 http://www.vector.nu

[email protected]

Rotterdam

VECTOR Aandrijftechniek B.V.

Industrieweg 175

NL-3044 AS Rotterdam

Postbus 10085

NL-3004 AB Rotterdam

Auckland

Christchurch

SEW-EURODRIVE NEW ZEALAND LTD.

P.O. Box 58-428

82 Greenmount drive

East Tamaki Auckland

SEW-EURODRIVE NEW ZEALAND LTD.

10 Settlers Crescent, Ferrymead

Christchurch

Moss

SEW-EURODRIVE A/S

Solgaard skog 71

N-1599 Moss

Tel. +64 9 2745627

Fax +64 9 2740165 http://www.sew-eurodrive.co.nz

[email protected]

Tel. +64 3 384-6251

Fax +64 3 384-6455 [email protected]

Tel. +47 69 241-020

Fax +47 69 241-040 http://www.sew-eurodrive.no

[email protected]

Lima

SEW DEL PERU MOTORES REDUCTORES

S.A.C.

Los Calderos, 120-124

Urbanizacion Industrial Vulcano, ATE, Lima

Tel. +51 1 3495280

Fax +51 1 3493002 http://www.sew-eurodrive.com.pe

[email protected]

Address List

Poland

Assembly

Sales

Service

Portugal

Assembly

Sales

Service

Romania

Sales

Service

Russia

Assembly

Sales

Service

Senegal

Sales

Sales

Singapore

Assembly

Sales

Service

Slovakia

Sales

Slovenia

Sales

Service

South Africa

Assembly

Sales

Service

Lodz

Coimbra

Bucuresti

Dakar

Serbia and Montenegro

Beograd

Singapore

Celje

SEW-EURODRIVE Polska Sp.z.o.o.

ul. Techniczna 5

PL-92-518 Lodz

SEW-EURODRIVE, LDA.

Apartado 15

P-3050-901 Mealhada

Sialco Trading SRL str. Madrid nr.4

011785 Bucuresti

St. Petersburg

ZAO SEW-EURODRIVE

P.O. Box 36

195220 St. Petersburg Russia

SENEMECA

Mécanique Générale

Km 8, Route de Rufisque

B.P. 3251, Dakar

DIPAR d.o.o.

Ustanicka 128a

PC Košum, IV floor

SCG-11000 Beograd

SEW-EURODRIVE PTE. LTD.

No 9, Tuas Drive 2

Jurong Industrial Estate

Singapore 638644

Bratislava

SEW-Eurodrive SK s.r.o.

Rybnicna 40

SK-83107 Bratislava

Zilina

SEW-Eurodrive SK s.r.o.

ul. Vojtecha Spanyola 33

SK-010 01 Zilina

Banská Bystrica

SEW-Eurodrive SK s.r.o.

Rudlovská cesta 85

SK-97411 Banská Bystrica

Pakman - Pogonska Tehnika d.o.o.

UI. XIV. divizije 14

SLO - 3000 Celje

Tel. +48 42 67710-90

Fax +48 42 67710-99 http://www.sew-eurodrive.pl

[email protected]

Tel. +351 231 20 9670

Fax +351 231 20 3685 http://www.sew-eurodrive.pt

[email protected]

Tel. +40 21 230-1328

Fax +40 21 230-7170 [email protected]

Tel. +7 812 3332522 +7 812 5357142

Fax +7 812 3332523 http://www.sew-eurodrive.ru

[email protected]

Tel. +221 849 47-70

Fax +221 849 47-71 [email protected]

Tel. +381 11 347 3244 / +381 11 288

0393

Fax +381 11 347 1337 [email protected]

Tel. +65 68621701

Fax +65 68612827 http://www.sew-eurodrive.com.sg

[email protected]

Tel. +421 2 49595201

Fax +421 2 49595200 http://www.sew.sk

[email protected]

Tel. +421 41 700 2513

Fax +421 41 700 2514 [email protected]

Tel. +421 48 414 6564

Fax +421 48 414 6566 [email protected]

Tel. +386 3 490 83-20

Fax +386 3 490 83-21 [email protected]

Johannesburg

SEW-EURODRIVE (PROPRIETARY) LIMITED

Eurodrive House

Cnr. Adcock Ingram and Aerodrome Roads

Aeroton Ext. 2

Johannesburg 2013

P.O.Box 90004

Bertsham 2013

Tel. +27 11 248-7000

Fax +27 11 494-3104 http://www.sew.co.za

[email protected]

41

42

Address List

South Africa

Spain

Assembly

Sales

Service

Sweden

Assembly

Sales

Service

Switzerland

Assembly

Sales

Service

Thailand

Assembly

Sales

Service

Tunisia

Sales

Turkey

Assembly

Sales

Service

Ukraine

Sales

Service

USA

Production

Assembly

Sales

Service

Capetown

Durban

Bilbao

Jönköping

Basel

Chon Buri

SEW-EURODRIVE (PROPRIETARY) LIMITED

Rainbow Park

Cnr. Racecourse & Omuramba Road

Montague Gardens

Cape Town

P.O.Box 36556

Chempet 7442

Cape Town

SEW-EURODRIVE (PROPRIETARY) LIMITED

2 Monaceo Place

Pinetown

Durban

P.O. Box 10433, Ashwood 3605

Tel. +27 21 552-9820

Fax +27 21 552-9830

Telex 576 062 [email protected]

Tel. +27 31 700-3451

Fax +27 31 700-3847 [email protected]

SEW-EURODRIVE ESPAÑA, S.L.

Parque Tecnológico, Edificio, 302

E-48170 Zamudio (Vizcaya)

SEW-EURODRIVE AB

Gnejsvägen 6-8

S-55303 Jönköping

Box 3100 S-55003 Jönköping

Alfred lmhof A.G.

Jurastrasse 10

CH-4142 Münchenstein bei Basel

Tel. +34 9 4431 84-70

Fax +34 9 4431 84-71 http://www.sew-eurodrive.es

[email protected]

Tel. +46 36 3442-00

Fax +46 36 3442-80 http://www.sew-eurodrive.se

[email protected]

SEW-EURODRIVE (Thailand) Ltd.

Bangpakong Industrial Park 2

700/456, Moo.7, Tambol Donhuaroh

Muang District

Chon Buri 20000

Tel. +41 61 417 1717

Fax +41 61 417 1700 http://www.imhof-sew.ch

[email protected]

Tel. +66 38 454281

Fax +66 38 454288 [email protected]

Tel. +216 1 4340-64 + 1 4320-29

Fax +216 1 4329-76 [email protected]

Tunis

Istanbul

T. M.S. Technic Marketing Service

7, rue Ibn EI Heithem

Z.I. SMMT

2014 Mégrine Erriadh

SEW-EURODRIVE

Hareket Sistemleri San. ve Tic. Ltd. Sti.

Bagdat Cad. Koruma Cikmazi No. 3

TR-34846 Maltepe ISTANBUL

Dnepropetrovsk

SEW-EURODRIVE

Str. Rabochaja 23-B, Office 409

49008 Dnepropetrovsk

Tel. +90 216 4419163 / 164 3838014/15

Fax +90 216 3055867 [email protected]

Greenville

SEW-EURODRIVE INC.

1295 Old Spartanburg Highway

P.O. Box 518

Lyman, S.C. 29365

Tel. +380 56 370 3211

Fax +380 56 372 2078 http://www.sew-eurodrive.ua

[email protected]

Tel. +1 864 439-7537

Fax Sales +1 864 439-7830

Fax Manuf. +1 864 439-9948

Fax Ass. +1 864 439-0566

Telex 805 550 http://www.seweurodrive.com

[email protected]

Address List

USA

Assembly

Sales

Service

Venezuela

Assembly

Sales

Service

San Francisco

Philadelphia/PA

SEW-EURODRIVE INC.

Pureland Ind. Complex

2107 High Hill Road, P.O. Box 481

Bridgeport, New Jersey 08014

Dayton

SEW-EURODRIVE INC.

30599 San Antonio St.

Hayward, California 94544-7101

SEW-EURODRIVE INC.

2001 West Main Street

Troy, Ohio 45373

Dallas

SEW-EURODRIVE INC.

3950 Platinum Way

Dallas, Texas 75237

Additional addresses for service in the USA provided on request!

Tel. +1 510 487-3560

Fax +1 510 487-6381 [email protected]

Tel. +1 856 467-2277

Fax +1 856 845-3179 [email protected]

Tel. +1 937 335-0036

Fax +1 937 440-3799 [email protected]

Tel. +1 214 330-4824

Fax +1 214 330-4724 [email protected]

Valencia

SEW-EURODRIVE Venezuela S.A.

Av. Norte Sur No. 3, Galpon 84-319

Zona Industrial Municipal Norte

Valencia, Estado Carabobo

Tel. +58 241 832-9804

Fax +58 241 838-6275 http://www.sew-eurodrive.com.ve

[email protected]

[email protected]

43

Gearmotors \ Industrial Gear Units \ Drive Electronics \ Drive Automation \ Services

How we’re driving the world

With people who think fast and develop the future with you.

With a worldwide service network that is always close at hand.

With drives and controls that automatically improve your productivity.

With comprehensive knowledge in virtually every branch of industry today.

With uncompromising quality that reduces the cost and complexity of daily operations.

With a global presence that offers responsive and reliable solutions.

Anywhere.

With innovative technology that solves tomorrow’s problems today.

With online information and software updates, via the Internet, available around the clock.

SEW-EURODRIVE

Driving the world

SEW-EURODRIVE GmbH & Co KG

P.O. Box 3023 · D-76642 Bruchsal / Germany

Phone +49 7251 75-0 · Fax +49 7251 75-1970 [email protected]

www.sew-eurodrive.com

advertisement

Key Features

  • Decentralized field control
  • Gateway functionality
  • ProfiBus communication
  • 24V brake control system
  • MOVIDRIVE® MCS20A-0040 drive inverter

Frequently Answers and Questions

What is the PHC11A-A040M1-P00K-01's function level?
The function level is 01, meaning it is the first function level.
What communication medium does the PHC11A-A040M1-P00K-01 use?
The PHC11A-A040M1-P00K-01 uses ProfiBus communication.
What is the maximum motor cable length for the PHC11A-A040M1-P00K-01?
The maximum motor cable length is 15 m.
What is the operating voltage range for the PHC11A-A040M1-P00K-01?
The operating voltage range for the PHC11A-A040M1-P00K-01 is 380 VAC - 10 % ... 500 VAC + 10 %.