- Industrial & lab equipment
- Electrical equipment & supplies
- SEW-Eurodrive
- MOVIPRO PHC11A-A040M1-P00K-01
- Operating instructions
- 44 Pages
SEW-EURODRIVE MOVIPRO PHC11A-A040M1-P00K-01 Drive and control unit Operating Instructions
The MOVIPRO PHC11A-A040M1-P00K-01 is a decentralized field control for stationary use in industrial and commercial systems. Energy is supplied on the mains end (400 V~). The unit is designed as a gateway between the higher-level controller and the connected frequency inverters. The PHC11A unit is equipped with a processing unit that serves as a SEW field controller responsible for communication between the PHC11A and the higher-level controller. The unit is also equipped with a MOVIDRIVE® MCS20A-0040 drive inverter for controlling asynchronous motors and a brake control system for 24V disc brakes.
advertisement
Assistant Bot
Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.
Gearmotors \ Industrial Gear Units \ Drive Electronics \ Drive Automation \ Services
MOVIPRO
®
PHC11A-A040M1-P00K-01
Edition 10/2006
11521813 / EN
O
perating
I
GC710000
nstructions
SEW-EURODRIVE – Driving the world
®
PHC11A ................................................................................... 31
Betriebsanleitung – MOVIPRO® PHC11A-A040M1-P00K-01
3
1
Important Notes
1
Operating Instructions
Important Notes
Safety and warning instructions
Always comply with the safety and warning instructions in this publication.
Hazard
Indicates an imminently hazardous situation which, if not avoided, WILL result in death or serious injury.
Warning
Indicates an imminently hazardous situation caused by the product which, if not avoided, WILL result in death or serious injury. This symbol also indicates potential for damage to property.
Caution
Indicates a potentially hazardous situation which, if not avoided, MAY result in minor injury or damage to products.
Note
Indicates a reference to useful information, e.g. on startup.
Documentation reference
Indicates a reference to a document, such as operating instructions, a catalog or a data sheet.
You must adhere to the operating instructions to ensure:
•
Fault-free operation
•
Fulfillment of any rights to claim under limited warranty
Therefore, read the operating instructions before you start operating the unit! The
operating instructions contain important information about service and should be kept near the unit.
4
Operating Instructions – MOVIPRO® PHC11A-A040M1-P00K-01
Important Notes
Designated use
MOVIPRO
®
PHC11A-A040M1-P00K-01 drive and control units are designed for stationary use in industrial and commercial systems for operating AC asynchronous motors with squirrel-cage rotors. These motors must be suitable for operation with frequency inverters. No other loads must be connected to the units.
In terms of power supply, the MOVIPRO
®
PHC11A-A040M1-P00K-01 drive and control units are designed for systems with direct supply that use pick-ups to draw power from a line cable. The components required for energy conversion are integrated in the unit.
Do not operate the unit until you have established that the machine complies with the
EMC Directive 89/336/EEC and that the conformity of the end product has been determined in accordance with the Machinery Directive 98/37/EEC (with reference to
EN 60204).
Observe all information on the technical data and the permitted conditions where the unit is operated. The rules and regulations of the Professional Association (Berufsgenossenschaft, BG), in particular BG rule B11 "Electromagnetic fields", must be observed during installation, startup and operation of systems with contactless energy transfer by induction for use in industrial workplaces.
Non-designated use
Customers are not permitted to remove covers or attempt to repair and set the
MOVIPRO
®
PHC11A-A040M1-P00K-01 drive and control unit themselves. Such actions are classified as non-designated use.
Only the manufacturing company is authorized to carry out repairs and make settings.
In case of malfunction, contact SEW-EURODRIVE GmbH & Co KG for information on how to proceed.
The manufacturer assumes no liability for operating the MOVIPRO
®
PHC11A-A040M1-
P00K-01 units in conditions other than those specified in these operating instructions.
Operational environment
The following uses are prohibited unless the units are expressly designed for the purpose:
• Use in potentially explosive areas.
• Use in areas exposed to harmful oils, acids, gases, vapors, dust, radiation, etc.
Waste disposal
Please follow the current national regulations.
Dispose of materials separately in accordance with the regulations in force, for example:
• Electronics scrap (circuit boards)
• Plastic (housing)
• Sheet metal
• Copper
• etc.
1
Operating Instructions – MOVIPRO® PHC11A-A040M1-P00K-01
5
2
Safety Notes
2 Safety Notes
Installation and startup
• Never install damaged products or take them into operation. Submit a complaint to the transportation company immediately in the event of damage.
• Installation, startup and service work may only be performed by trained
personnel observing applicable accident prevention regulations and operating instructions! The regulations in force (e.g. EN 60204, VBG 4, DIN-VDE
0100/0113/0160) must also be complied with. The following rules and regulations apply to the operator:
– Generally recognized safety rules.
– EC guidelines or other country-specific regulations
• Follow the specific instructions during installation and startup of the other components, such as motor and brake.
• Make sure that preventive measures and protection devices correspond to the
applicable regulations (e.g. EN 60204 or EN 50178).
Required preventive measures:
Systems with MOVITRANS
®
• Protective separation DIN VDE 0100-410, 1997
(IEC 60364-4-41, 2002)
• Low-impedance equipotential bonding on the machine frame
• ESD protection (for mobile components)
Systems with power supply module
• Grounding of the unit
• The unit meets all requirements for safe disconnection of power and electronics connections in accordance with EN 61800. All connected circuits must also satisfy
the requirements for safe disconnection. If safe disconnection is required, the connected signal circuits have to meet the requirements according to SELV or PELV.
Operation and service
• Before removing the protective cover, disconnect the unit from the supply
system. Dangerous voltage levels may still be present inside the unit and at the terminal strips up to 10 minutes after mains disconnection.
• When the protective cover is removed, the unit has enclosure IP00. Dangerous
voltages are present at all components except for the control electronics. The unit must be closed during operation.
• When the unit switch is in the ON position, dangerous voltages are present at the output terminals as well as any connected cables and motor terminals. This also applies even when the unit is inhibited and the motor is at standstill.
• Just because the operation LED and other display elements have gone out does
not mean that the unit has been disconnected from the supply system and is de-
energized.
• Internal safety functions or a mechanical blockage may cause the motor to
stop.
Removing the cause of the malfunction or performing a reset can cause the drive
to restart automatically.
As this is prohibited for the driven machine for safety reasons, disconnect the unit from the power supply before correcting the fault. In such cases, it is also forbidden for the "Auto Reset" (P841) to be activated.
6
Operating Instructions – MOVIPRO® PHC11A-A040M1-P00K-01
Safety Notes
Safety technology
• The inverter output may only be switched when the output stage is inhibited.
Switching the inverter output when the output stage is enabled leads to increased wear and will finally cause irreparable damage to the switch contacts. The switching equipment must be selected in accordance with the maximum DC voltage.
Warning of malfunctions
• The MOVIPRO
®
PHC11A-A040M1-P00K-01 drive and control units may not
execute any safety functions without higher-level safety systems unless expressly designed for this purpose. Malfunctions in the drive and control units of the
MOVIPRO
®
PHC11A-A040M1-P00K-01 product series can result in injuries to persons and damage to material and equipment.
•
Use higher-level safety systems to ensure protection of equipment and personnel!
Dangerous voltages!
• Do not connect or disconnect any plug connectors or interface connections when voltage is applied!
Mechanical protection
• The complete energy and control electronics is accommodated in a modular IP64
enclosure to provide protection against contact.
• The energy interfaces are designed using touch-safe plug connectors with IP65
protection (if locked).
• The connections for resolver and sensor/actuator boxes via M23 plug connector are designed in IP67 protection (when connected) .
• All M12 connections (sensors/actuators/diagnostic interfaces) are designed in
degree of protection IP67.
Electrical protection
Interfaces
ESD protection
Shielding
• All outgoing interfaces for energy supply (pick-up connections), motor connection and the 24 V voltage supply are designed in such a way (shape or color coded)
that they cannot be mixed up.
• The connectors of the resolver connection are color coded so that they cannot be
mixed up.
• Sensor and actuator connections are designed with standardized M23 connectors so that they cannot be mixed up.
• A high-resistance discharge with a resistance of 1 to 100 M
Ω
is permitted for
ESD protection in the stationary system section.
•
Only use shielded control cables.
•
Connect the shield by the shortest possible route and make sure it is grounded
over a wide area at both ends. Ground one end of the shield via suppression capacitor (220 nF/50 V) to avoid ground loops.
•
If using double-shielded cables, ground the outer shield on the unit end and the inner shield on the other end.
2
Operating Instructions – MOVIPRO® PHC11A-A040M1-P00K-01
7
3
Unit Design
Nameplate
3 Unit Design
The following short name is used in this operating instruction.
Designation
MOVIPRO
®
PHC11A-A040M1-P00K-01 drive and control unit
Short name
PHC11A
3.1
Nameplate
Nameplate
Each unit has a nameplate that provides important information.
Figure 1: Nameplate of the PHC11A
U Voltage f Frequency
I Current
T Temperature
P Power
60181AXX
8
Operating Instructions – MOVIPRO® PHC11A-A040M1-P00K-01
Unit Design
Unit designation
3.2
Unit designation
The units of the MOVIPRO
®
product series have a unit designation that provides important information on the drive and control unit type:
P H C 1 1 A - A 040 M 1 - P 00 K - 01
Function level version:
01 = First function level
Function level:
K = Customer-specific
Protocol and version:
00 = No meaning
Communication medium:
P = ProfiBus
Number of motor connectors:
1 = 1 motor connector
Type of power connector:
M = Motor connector
Maximum S1 power:
040 = 4.0 kVA
Power input type:
A = AC
Version:
A = First generation
Depth of housing:
1 = 300 mm
Height of housing:
1 = 70 mm (without cooling fins)
Housing type:
C = Modular
Control type:
H = Drive control
Product family:
P = MOVIPRO
®
3
Operating Instructions – MOVIPRO® PHC11A-A040M1-P00K-01
9
3
Unit Design
Scope of delivery
3.3
Scope of delivery
Basic unit
The scope of delivery includes the PHC11A-A040M1-P00K-01 basic unit.
• PHC11A-A040M1-P00K-01 basic unit
Components
The PHC11A modular housing includes the following components:
• MOVIDRIVE
®
MCF20A0040 drive inverter
• Supply system rectifier for DC link conversion
• Brake control for 24 V brakes from SEW
• SEW field control with ProfiBus
• Connectors (without mating connectors) for
– 2 x sensors, actuators
– 1 x power supply connection
– 1 x RS232 service
– 1 x RS485 service
– 1 x motor connector
– 2 x braking resistor connection
– 2 x ProfiBus
10
Operating Instructions – MOVIPRO® PHC11A-A040M1-P00K-01
Unit Design
Scope of delivery
Part number
SEW-EURODRIVE identifies the units with the following part numbers:
Unit
MOVIPRO
®
PHC11A-A040M1-P00K-01 drive and control unit
Part number
13000438
Additional components
The scope of delivery does not include installation equipment, mounting accessories or connection cables.
If you have questions about which equipment/material to choose, please contact SEW-
EURODRIVE GmbH & Co KG.
Motor cables
We recommend the following cables for connecting PHC11A to the motor:
• With motor round connector (M23) / part number 1 172 494 3
3
• With ASB8 connector (HAN 10E) / part number 1 172 679 2
57744AXX
• With terminal box on motor / part number 1 172 242 8
58241AXX
Operating Instructions – MOVIPRO® PHC11A-A040M1-P00K-01
58242AXX
11
3
Unit Design
Unit design
3.4
Unit design
The following figure shows the unit design of PHC11A:
[4]
[1] [2]
Figure 2: PHC11A-A040M1-P00K-01 basic unit
[1]
[2]
[3]
[4]
T-slot profiles
Heat sink
Front panel connectors
Housing cover
[3]
60213AXX
3.5
Operating principle
Task
The PHC11A unit is designed as decentralized field control for stationary use in industrial and commercial systems. Energy is supplied on the mains end (400 V~).
Observe all information on the technical data and the permitted conditions where the unit is operated.
12
Operating Instructions – MOVIPRO® PHC11A-A040M1-P00K-01
Structure
Unit Design
Power electronics
The following block circuit diagram shows the connections of peripherals with
MOVIPRO
®
PHC11A:
3
RS232
ProfiBus In
ProfiBus Out
Dig. I/O 1
Dig. I/O 2
R485
M12
One-
Wire-
Modul
M23
M23
M12
RS232
I/O
ProfiBus
SEW Feldsteuerung
CPU
RS 485
SBus
FU
=
»
BGR
HAN Q8
HAN Q5 HAN Q8
M1
Bremswiderstand
Fahrantrieb M1
Figure 3: Block circuit diagram
Netzzuleitung
60179AXX
3.6
Power electronics
MOVIDRIVE
®
MCS20A-0040 drive inverter
The MOVIDRIVE
®
MCS20A-0040 drive inverter is not equipped with a fan. It is connected to the heat sink in cold-plate technology.
The supply voltage is DC 500 V. A 24 V switched-mode power supply with 4 A continuous output power is integrated, independent of the inverter electronics.
The MOVIDRIVE
®
drive inverter type MCS20A-0040 serves for controlling asynchronous motors.
Brake control system
Observe the information on the system properties and motor assignments in the
MOVIDRIVE
®
compact
system manual, part number 11493410/EN.
Brake control is responsible for the power supply and control of the 24 V disc brakes used in the motors connected to PHC11A.
In the PHC11A unit described in these operating instructions, brake control is installed internally. A brake rectifier type BMV 5 is used for the PHC11A unit.
When configuring the motors, note that if brake motors are used, an SEW brake coil must be fitted for each one. When selecting the SEW brake coil, note the permitted operating voltage for the brake coil.
The brake coil type is determined depending on the motor power.
Operating Instructions – MOVIPRO® PHC11A-A040M1-P00K-01
13
3
Unit Design
Control technology
3.7
Control technology
Processing unit
The PHC11A drive and control unit is equipped with a processing unit. This SEW field
controller is responsible for communication between PHC11A and the higher-level controller. It functions as a gateway between the higher-level controller and the connected frequency inverters.
For a detailed descriptiion of the interfaces and the gateway functionality, see the
"MOVIPRO
®
Interface Description" specification, part number 11471417/EN.
To connect the SEW field controller to a ProfiBus network, a suitable ProfiBus module is connected. The application software can easily be loaded to the processing unit via the ProfiBus interface or RS232 diagnostic interface.
14
Operating Instructions – MOVIPRO® PHC11A-A040M1-P00K-01
Installation
Installation notes
4 Installation
4.1
Installation notes
Minimum clearance
Cooling
Installation
Comply with the general safety notes during installation!
During installation, provide adequate space on the connection panel for the connection
cables in accordance with the dimension drawing. page 33.
Make sure that the heat sink segments can dissipate heat by means of free convection.
When attaching the unit to a mounting plate, the best dissipation properties can be achieved by:
• Using a mounting plate that is the same size as the unit itself
• Ensuring that the highest cooling fin is at least 25 mm away from the mounting plate
The unit is fitted with bends on the front end for mounting. These bends can be used to attach suitable mounting elements (e.g. T-slot nuts, screws with appropriate screw heads). The units can be installed in two ways:
• Version A: Screws are secured to the PHC housing from the back through the fastening elements.
• Version B: Screws are secured to the PHC housing from the front through the fastening element.
4
Operating Instructions – MOVIPRO® PHC11A-A040M1-P00K-01
15
4
Installation
Installation notes
The following figure shows the mounting hole positions:
[1]
[2]
[3]
25
[4] [5]
16
Mounting position
[A]
Figure 4: Installing the PHC11A
[1]
[2]
[3]
[4]
[5]
Corner profile with threaded hole (M8 x 20)
Fastening element
Housing cover
Tapped hole (M8 x 20)
Screws for mechanical connection
[B]
60214AXX
Use suitable supports or spacers to ensure optimum heat convection.
You must maintain a minimum distance of 25 mm from the highest cooling fin to the neighboring areas.
Maximum permitted tightening torque for the retaining screws: 3.2 Nm
The mounting position for units with cooling fins is vertical to allow for vertical air convection between the cooling fins.
Any other position is not permitted due to the reduced heat convection. Operation in a different mounting position can cause the unit to overheat, leading to irreparable damage.
Operating Instructions – MOVIPRO® PHC11A-A040M1-P00K-01
Installation
Installation notes
4
60215AXX
Figure 5: Permitted mounting positions for PHC11A
Always position the unit so that it will not collide with other components or design elements along the travel distance.
Dimensions of the T-slot profiles
When selecting the mounting elements, observe the dimensions of the angle profiles shown in the figure below.
R5,5
6
15
R7
15
Figure 6: Dimensions of the angle profiles
The dimensions of the PHC11A unit are shown in dimension drawing page 34.
57253AXX
Operating Instructions – MOVIPRO® PHC11A-A040M1-P00K-01
17
4
Installation
Installation notes
Shielding
Separate cable ducts
Unit output
•
Only use shielded motor and control cables.
•
Connect the shield by the shortest possible route and make sure it is grounded
over a wide area at both ends. Ground one end of the shield via suppression capacitor (220 nF/50 V) to avoid ground loops.
•
For cables with single shielding, apply the shielding to both ends.
•
For cables with double shielding (e. g. hybrid cable), apply the outer shielding to the MOVIPRO
®
and the inner shielding to the other end (e. g. motor).
Route power cables and electronics cables in separate cable ducts.
Connect only ohmic/inductive loads such as, for example, motors, at motor
connector -10X1. Never connect capacitive loads!
18
Digital inputs/digital outputs
60217AXX
Figure 7: Connection of inductive/ohmic loads at the motor connector
The motor supply cable must not exceed a maximum length of 15 m.
The digital inputs are electrically isolated by opto-couplers.
The digital outputs are electrically isolated by opto-couplers and are short-circuit
proof.
Grounding and equipotential bonding
Caution
Do not connect external brake rectifiers, for example in the motor terminal box.
ProfiBus IDmodule
Do not install or remove the ProfiBus ID-module when voltage is applied.
Switch off the unit before plugging in the ProfiBus ID-module.
Use two knurled screws to attach the ProfiBus ID-module. Tighten the knurled screws manually.
Maximum permitted tightening torque for the retaining screws: 0.2 Nm
Operating Instructions – MOVIPRO® PHC11A-A040M1-P00K-01
Installation
Installation notes
Position of the connection points
The connection points on the MOVIPRO
®
units for grounding or equipotential bonding are marked on the housing corners by a symbol.
Design
The holes for grounding are prepared for M5 self-tapping bolts, e.g. M5 x 12 to
DIN ISO 3506 or equivalent.
Proceed as follows to ground the unit:
1. First, place a terminal clip onto the ground bore, next the crimp cable lug for M5 and finally the tooth lock washer.
2. Tighten the elements using a self-tapping screw.
4
X
[1] [2]
[6] [5] [4] [3]
Figure 8: Grounding installation
[1]
[2]
[3]
[4]
[5]
[6]
Corner profile with M8 threaded hole
Housing bolts
Terminal clip
Crimp cable lug for M5
Tooth lock washer
Bolt, self-tapping
Operating Instructions – MOVIPRO® PHC11A-A040M1-P00K-01
X
60218AXX
19
4
Installation
Installation notes
Never loosen the connection screws at the housing corners.
Never secure the grounding or equipotential bonding cable using the housing
connection screws. They are tightened with a predefined tightenting torque at the factory. Once a housing connection screw is loosened, the sealing property and consequently degree of protection IP65 can no longer be ensured because the profiles have become distorted.
20
Operating Instructions – MOVIPRO® PHC11A-A040M1-P00K-01
Installation
Connections
4.2
Connections
The following sections describe the connections of PHC11A.
[1] [2] [3] [4] [5] [6] [7] [8] [9]
4
60216AXX
Figure 9: Connection assignment of PHC11A
[5]
[6]
[7]
[8]
[9]
[1]
[2]
[3]
[4]
-20x1
-20X2
-20X13
-20x14
-30X5
-10X13
-10X1
-10X5
-0X1
Connection for ProfiBus out (M12 5-pole, B-coded socket)
Connection for ProfiBus in (M12 5-pole, pins B-coded)
Connection for RS232 service (M12 5-pole, pins A-coded)
Connection for RS485 service (M12 5-pole, socket A-coded)
Connection for I/O field control (M23, 12-pole, socket 0°-coded)
Connection for I/O frequency inverter (M23 12-pole, socket 0°-coded)
Connection for motor connector (HAN Q8)
Connection for braking resistor (HAN Q5 socket)
Connection for supply system lead (HAN Q8 pins)
4.3
Wiring diagrams
Assignment -20X2: ProfiBus out, M12 B-coded (socket)
3 4
2 1
Figure 10: ProfiBus out, M12, 5-pole, B-coded (socket)
4
5
2
3
PIN
1
Assignment
+5 V
A
DGND
B
N.C.
Function
Supply voltage
Data line -
Reference potential
Data line +
60252AXX
Operating Instructions – MOVIPRO® PHC11A-A040M1-P00K-01
21
4
Installation
Wiring diagrams
Assignment -20x1: ProfiBus in, M12 B-coded (pins)
4 3
1 2
Figure 11: ProfiBus in , M12, 5-pole, B-coded (pins)
Function
4
5
2
3
PIN
1
Assignment
N.C.
A
N.C.
B
N.C.
Data line -
Data line +
Assignment -20X14: RS485 – connection for RS485 interface, M12 A-coded (socket)
3 4
2 1
Figure 12: Connection for RS485 interface – M12, 5-pole, A-coded (socket)
4
5
2
3
PIN
1
Assignment
VO24V
RS485-
0V24
RS485+
N.C.
Function
24 V supply voltage
RS-
Reference potential 24V
RS+
–
Assignment -20x13: RS232 service, M12 A-coded (socket)
3 4
2 1
Figure 13: RS232 service, M12, 5-pole, A-coded (socket)
4
5
2
3
PIN
1
Assignment
VO24V
TxD
0V24
RxD
N.C.
Function
24 V voltage supply
RS-
Reference potential
RS-
60251AXX
60254AXX
60254AXX
22
Operating Instructions – MOVIPRO® PHC11A-A040M1-P00K-01
Installation
Wiring diagrams
Assignment -10X1: Motor connection, HAN Q8 (socket)
2
3
5
8
1
4
PE
6
7
Figure 14: Motor connection, 5-pole, HAN Q8 (socket)
Terminal
-10X1.1
-10X1.2
-10X1.3
-10X1.4
-10X1.5
-10X1.6
-10X1.7
-10X1.8
-10X1.PE
Assignment
U
BG 0.14
W
BG 0.15
FU Ref 10V+
BG .13
V
FU AI21
Weight
Function
Motor connection phase U
Brake with high-speed excitation
Motor connection phase W
0V24 brake
TF+/TH+
Brake +24 V
Motor connection phase V
TF-/TH-
Equipotential bonding
Assignment -10X9: Braking resistor, HAN Q5 (socket)
57664AXX
4
PE
1
3
4
2
5
Figure 15: Braking resistor, 5-pole, HAN Q5 (socket)
Function Terminal
-10X9.1
-10X9.2
-10X9.3
-10X9.4
-10X9.5
-10X9.PE
Assignment
N.C.
N.C.
R+
N.C.
R-
Weight
Braking resistor +
Braking resistor -
Equipotential bonding
58255AXX
Operating Instructions – MOVIPRO® PHC11A-A040M1-P00K-01
23
4
Installation
Wiring diagrams
Assignment -10X13: Digital inputs and outputs, M23 0°-coded, (socket)
1 9 8
2
3
10
12
4
11
5
6
7
Figure 16: Digital inputs and outputs, M23, 12-pole, 0°-coded (socket)
Terminal
-30X5.1
-30X5.2
-30X5.3
-30X5.4
-30X5.5
-30X5.6
-30X5.7
-30X5.8
-30X5.9
-30X5.10
-30X5.11
-30X5.12
Assignment
DI00
DI01
DI02
DI03
DI04
DI05
DO00
DO01
0V24
0V24
+24V
Weight
Function
Digital input frequency inverter
Digital input frequency inverter
Digital input frequency inverter
Digital input frequency inverter
Digital input frequency inverter
Digital input frequency inverter
Digital output frequency inverter
Digital output frequency inverter
Reference potential
Reference potential
24 V supply voltage
Equipotential bonding
58256AXX
24
Operating Instructions – MOVIPRO® PHC11A-A040M1-P00K-01
Installation
Wiring diagrams
Assignment -30X5: Digital inputs and outputs, M23 0°-coded (socket)
1 9 8
2
3
10 12
4
11
5
6
7
Figure 17: Digital inputs and outputs, M23, 12-pole, 0°-coded (socket)
Terminal
-30X5.1
-30X5.2
-30X5.3
-30X5.4
-30X5.5
-30X5.6
-30X5.7
-30X5.8
-30X5.9
-30X5.10
-30X5.11
-30X5.12
Assignment
DI00
DI01
DI02
DI03
DI04
DI05
DO00
DO01
0V24
0V24
+24V
Weight
Function
Digital input of field controller
Digital input of field controller
Digital input of field controller
Digital input of field controller
Digital input of field controller
Digital input of field controller
Digital output of field controller
Digital output of field controller
Reference potential
Reference potential
24 V supply voltage
Equipotential bonding
58256AXX
4
Operating Instructions – MOVIPRO® PHC11A-A040M1-P00K-01
25
5
I
Startup
General notes
5 Startup
5.1
General notes
It is essential to comply with the safety notes in section 2 during startup!
Prerequisites for startup
The following prerequisites must be met for these steps:
• PHC11A must be connected in accordance with the instructions in the Installation section.
• The system and connected drives must be configured correctly. You can configure the PHC11A using the MOVITOOLS
®
and MOVIVISION
®
software.
• PHC11A must be supplied with voltage.
Important
• Potentially fatal voltages may occur if the unit is connected incorrectly. Ensure that the unit is connected as specified.
• Appropriate safety measures must be taken to prevent the motor from starting unintentionally.
• Moreover, additional safety precautions must be taken to avoid injury to persons and damage to machinery.
• Comply with the safety notes during startup.
• When the status display goes out, this does not mean that the unit has been disconnected.
5.2
Motors and brakes
Motors
Brakes
For U/f operation of PHC11A, only the following SEW standard motors in star and delta connection are permitted:
• DV motors
Only brakes with a coil voltage of 24 V are permitted. All other brakes may destroy the
PHC11A.
26
Operating Instructions – MOVIPRO® PHC11A-A040M1-P00K-01
Operation and Service
Operating notes
6 Operation and Service
6.1
Operating notes
Duty types
The following operating modes are determined according to ED information (information on the cyclic duration factor) EN 60034-1 on ambient temperature
ϑ
U
0 °C... +40 °C at
I
D
= 100 % I additional32
N
and f
PWM
= 4 kHz, cyclic duration factor 50 % cdf, T = 1 h; each
degree Celsius in temperature results in a decreased cdf of 4 %.
Operating mode
S1
S2
S3
S4...S10
Explanation
Continuous duty: Operation at a constant load; the motor reaches thermal equilibrium.
Short-time duty: Operation at constant load for a given time followed by a time at rest.
The motor returns to ambient temperature during the rest period.
Intermittent periodic duty: The starting current does not significantly affect the temperature rise. Characterized by a sequence of identical duty cycles, each including a time of operation at constant load and a time at rest. Described by the "cyclic duration factor
(cdf)" in %.
Intermittent periodic duty: The starting current affecting the temperature rise. Characterized by a sequence of identical duty cycles, each including a time of operation at constant load and a time at rest. Described by the "cyclic duration factor (cdf)" in % and the number of cycles per hour.
6
ma x ma x ma x
Cyclic duration factor (cdf)
03135AXX
Figure 18: Duty types S1, S2 and S3
The cyclic duration factor (cdf) is the ratio between the period of loading and the duration of the duty cycle. The duration of the duty cycle is the sum of times of operation and times at rest and de-energized. A typical value for the duration of the duty cycle is ten minutes.
CDF = sum of times of operation (t1 + t2 + t3) duty cycle duration (T)
• 100 [%]
Operating Instructions – MOVIPRO® PHC11A-A040M1-P00K-01
27
6
Operation and Service
Fault information
Important:
• When the unit is switched on, dangerous voltages are present at the output terminals as well as any connected cables and motor terminals. This also applies even if the
unit is inhibited and the motor is at standstill.
• Do not change the switch under load.
• Disconnect the unit from voltage supply before performing work on the unit.
Dangerous voltages may still be present for up to ten minutes after disconnection from the power supply source.
• The unit output may only be switched when the output stage of the inverter is
inhibited.
6.2
Fault information
Fault memory
Only the manufacturing company is authorized to carry out repairs.
In case of malfunction, contact SEW-EURODRIVE GmbH & Co KG for information on how to proceed.
The error memory (P080) stores the last five error messages (errors t-0 to t-4). The error message of longest standing is deleted whenever more than five error messages have occurred. The following information is stored when a malfunction occurs:
• Error which has occurred
• Status of binary inputs/outputs
• Operating status of the inverter
• Inverter status
• Heat sink temperature
• Speed
• Output current
• Active current
• Unit utilization
• DC link voltage
• Hours of operation
• Enable hours
• Parameter set
• Motor utilization
28
Operating Instructions – MOVIPRO® PHC11A-A040M1-P00K-01
Operation and Service
Fault information
Switch-off responses
Immediate stop
Rapid stop
Emergency stop
Reset
There are three switch-off responses depending on the error. The inverter remains inhibited in fault status:
The unit can no longer brake the drive; the output stage goes to high resistance in the event of a fault and the brake is applied immediately (DBØØ "/Brake" = "0").
The drive is braked with the stop ramp t13/t23. The brake is applied once the stop speed is reached (DBØØ "/Brake" = "0"). The output stage goes to high resistance after the brake reaction time has elapsed (P732 / P735).
The drive is braked with the emergency ramp t14/t24. The brake is applied once the stop speed is reached (DBØØ "/Brake" = "0"). The output stage goes to high resistance after the brake reaction time has elapsed (P732 / P735).
An error message can be acknowledged by:
• Switching the voltage supply on and off
Recommendation: Adhere to a minimum switch-off time of 10 s.
• Reset with parameter 840 = "YES" or [Parameter] / [Manual reset].
• Auto reset performs up to five unit resets with an adjustable restart time.
Do not use auto-reset with drives where an automatic restart could represent a danger to people or units.
Timeout active
If the inverter is controlled via a communication interface (fieldbus, RS485 or SBus) and the power was switched off and back on again or a fault reset was performed, then the enable remains ineffective until the inverter receives valid data again via the interface, which is monitored with a timeout.
6
Operating Instructions – MOVIPRO® PHC11A-A040M1-P00K-01
29
6
Operation and Service
Shut down
6.3
Shut down
To shut down PHC11A, disconnect the unit using appropriate measures.
Important:
Dangerous voltages may still be present at the terminals and connections for up to ten minutes after switching off the PHC11A.
6.4
Transportation
Observe the following instructions when transporting the PHC11A unit:
• Cover the connections with the supplied protective caps before transportation.
• Pace the unit on the heat sink or on the side without connectors during transportation.
• Make sure that the unit is not subject to mechanical impact during transport.
6.5
Storage
Observe the following instructions when storing the PHC11A unit:
• If you shut down and store the unit for a longer period, you must cover the connections with the protective caps supplied.
• Only store the unit on the heat sink or on the side without connectors during transportation.
• Make sure that the unit is not subject to mechanical impact during storage.
6.6
Maintenance
PHC11A does not require any maintenance. The manufacturer does not stipulate any inspection work that has to be performed regularly.
30
Operating Instructions – MOVIPRO® PHC11A-A040M1-P00K-01
Technical Data
MOVIPRO® PHC11A
kVA f i
P Hz n
7 Technical Data
7.1
MOVIPRO
®
PHC11A
The following tables list the technical data for PHC11A.
General data
Feature
Interference immunity
Ambient temperature
Derating ambient temperature
Climate class
Storage temperature
Enclosure
Weight
Dimensions W x H x D
Size
ϑ
U
ϑ
L
Data
meets EN 61800-3 (in preparation)
-5 °C ... +40 °C
(Non-condensing, no moisture condensation)
P
N
reduction: 3 % I
N
per K to max. 60 °C
When the temperature of the heat sink increases to more than 80°C, the device switches off and the fault message "Overtemperature" is generated.
EN 60721-3-3
Class 3K3
-25 °C ... +70 °C (EN 60721-3-3, class 3K3)
IP65
11 kg
420 x 300 x 110 mm (connector not taken into account)
General data for power section
Feature
Operating mode
Overall rated output power
Rated current
Data for power section input
Feature
Operating voltage
Rated input current
Size
ϑ
L
P
N
I
N
Size
U
E
I pick-up
Data
continuous duty (EN 60149-1-1 and 1-3)
9.5 A
AC
Data
380 V
AC
- 10 % ... 500 V
AC
+ 10 %
8.6 A
AC
7
The overall rated power depends on the connected load. The total rated power is decisive for the maximum output power of the unit. The power data of the individual axes may deviate from these values.
Operating Instructions – MOVIPRO® PHC11A-A040M1-P00K-01
31
7
kVA f i
P Hz n
Technical Data
MOVIPRO® PHC11A
DDate output power section axis - 10x1
Feature
Operating mode
Rated output power
Rated output current
Current limitation
Output voltage
PWM frequency
Speed range / resolution
Size
ϑ
L
P
N
I
N
I max
U
A f
PWM n
쑶
/ n
A
Maximum motor cable length
Constant load S1
Recommended motor power
P
Mot
P
Mot
Data
continuous duty (EN 60149-1-1 and 1-3)
4 kW
9.5 A
AC motor and regenerative 150 % I
N
0..0.500 V
AC
Can be set: 4/8/16 kHz (P860/P861)
-5000 ... 0 ... +5000 min
-1
/ 0.2 min
-1 across the entire range
15 m
4 kW (5.3 HP)
24 V voltage supply
Feature
24 V sensor power supply VO24_DIO
(sensors/actuators)
24 V voltage supply VO24
(communication interfaces / bus)
24 V emergency stop relays
Data
Output voltage 24 V -/-5 %
Total output current limited to at least 500 mA
Short circuit and overload protection
Not interference-voltage-proof
Output voltage 24 V -/-5 %
Total output current limited to at least 500 mA
Short circuit and overload protection
Not interference-voltage-proof
Output voltage 24 V -/-5 %
Total output current limited to at least 3.5 A
Short circuit and overload protection
Not interference-voltage-proof
Digital inputs and outputs
Feature
Digital inputs
Digital outputs
Data
PLC compatible according to EN 61131-2 R i f g
LOW"
≈
3 k
Ω
≈
2.8 kHz 15 V...30 V input "HIGH" -3 V...5 V input"
PLC compatible according to EN 61131-2 I
OUT
=
500 mA (per output) output "HIGH" 24 V +/- 5% output
"LOW" 0 V +5%
Short circuit and overload protection
Not interference-voltage-proof
32
Operating Instructions – MOVIPRO® PHC11A-A040M1-P00K-01
Technical Data
Dimension drawing
kVA f i
P Hz n
7.2
Dimension drawing
PHC11A-A040M1-
P00K-01
The dimension drawing shows the mechanical dimensions of PHC11A:
7
Standards and certifications
∅
6.5 / M8x20
[A]
390
420
Figure 19: Dimension drawing for PHC11A, dimensions in mm
7.3
Additional information
Publications
For further information, refer to the following documentation:
Documentation
MOVIDRIVE
®
MCF/MCV/MCS20A operating instructions
MOVIDRIVE
® compact MCF/MCV/MCS20A operating instructions
MOVIDRIVE
®
compact system manual
60219AXX
Publication number
11282916/EN
10556214/EN
11533811/EN
The PHC11A drive and control unit was developed and tested based on the following standards:
• VDE 0100
• EN 954
• EN 61800
Operating Instructions – MOVIPRO® PHC11A-A040M1-P00K-01
33
8
Index
34
8 Index
A
Accessories
.........................................................11
Additional information
.........................................33
Publications
..................................................33
Standards and certifications
B
Basic units
...........................................................10
Block circuit diagram
...........................................13
Brakes
.................................................................26
C
Cable ducts
.........................................................18
Components
........................................................10
Connections
................................................. 13
Control technology
..............................................14
Cooling
................................................................15
Cyclic duration factor
..........................................27
D
Designated use
.....................................................5
Digital inputs
.......................................................18
Digital outputs
.....................................................18
Dimension drawing
.............................................33
Dimensions
.........................................................33
E
equipotential bonding
..........................................19
Error memory
......................................................28
F
Fault information
.................................................28
G
Grounding
.................................................... 18
I
Installation
...........................................................15
Installation notes
.................................................15
Integrated components
SEW field controller
......................................14
M
Maintenance
.......................................................30
Minimum clearance
.............................................15
Motor cables
.......................................................11
Motors
.................................................................26
Mounting
.............................................................15
Mounting position
................................................16
N
Nameplate
.............................................................8
Non-designated use
..............................................5
O
Operating modes
................................................27
Operating notes
.................................................. 27
Operating principle
............................................. 12
Operational environment
...................................... 5
P
Part number
....................................................... 11
Power electronics
............................................... 13
ProfiBus ID-module
............................................ 18
Protective measures
............................................ 6
Publications
........................................................ 33
R
Reset
.................................................................. 29
S
Safety Notes
......................................................... 6
Safety notes
Installation and startup
................................... 6
Operation and service
.................................... 6
Safety requirements
Electrical protection
....................................... 7
ESD protection
............................................... 7
Interfaces
....................................................... 7
Mechanical protection
.................................... 7
Shielding
........................................................ 7
Scope of delivery
................................................ 10
SEW field controller
............................................ 14
Shielding
............................................................ 18
Short name
........................................................... 8
Shut down
.......................................................... 30
Standards
........................................................... 33
Standards and certifications
............................... 33
Startup
Procedure
.................................................... 26
Storage
............................................................... 30
Structure
............................................................. 13
Switch-off response to faults
.............................. 29
T
Technical data
Data power section output
........................... 32
Digital inputs and outputs
............................ 32
General information
..................................... 31
General power section
................................. 31
Power section input
..................................... 31
24 V voltage supply
..................................... 32
Timeout active
.................................................... 29
Transportation
.................................................... 30
T-slot profiles
Dimensions
.................................................. 17
Operating Instructions – MOVIPRO® PHC11A-A040M1-P00K-01
Index
U
Unit design
............................................................8
Unit output
...........................................................18
Use
designated
......................................................5
W
warning instructions
..............................................4
Waste disposal
......................................................5
Wiring diagrams
................................................. 21
Braking resistor
............................................ 23
Connection for RS485 interface
Digital inputs/outputs
............................. 24
Motor connection
......................................... 23
ProfiBus In
................................................... 22
ProfiBus Out
................................................ 21
RS232 service
............................................. 22
8
Operating Instructions – MOVIPRO® PHC11A-A040M1-P00K-01
35
36
Address List
Address List
Germany
Headquarters
Production
Sales
Service
Competence Center
Bruchsal
Central
Gear units /
Motors
Central
Electronics
SEW-EURODRIVE GmbH & Co KG
Ernst-Blickle-Straße 42
D-76646 Bruchsal
P.O. Box
Postfach 3023 • D-76642 Bruchsal
SEW-EURODRIVE GmbH & Co KG
Ernst-Blickle-Straße 1
D-76676 Graben-Neudorf
SEW-EURODRIVE GmbH & Co KG
Ernst-Blickle-Straße 42
D-76646 Bruchsal
North
East
SEW-EURODRIVE GmbH & Co KG
Alte Ricklinger Straße 40-42
D-30823 Garbsen (near Hannover)
SEW-EURODRIVE GmbH & Co KG
Dänkritzer Weg 1
D-08393 Meerane (near Zwickau)
South
West
SEW-EURODRIVE GmbH & Co KG
Domagkstraße 5
D-85551 Kirchheim (near München)
SEW-EURODRIVE GmbH & Co KG
Siemensstraße 1
D-40764 Langenfeld (near Düsseldorf)
Drive Service Hotline / 24 Hour Service
Additional addresses for service in Germany provided on request!
Tel. +49 7251 75-0
Fax +49 7251 75-1970 http://www.sew-eurodrive.de
Tel. +49 7251 75-1710
Fax +49 7251 75-1711 [email protected]
Tel. +49 7251 75-1780
Fax +49 7251 75-1769 [email protected]
Tel. +49 5137 8798-30
Fax +49 5137 8798-55 [email protected]
Tel. +49 3764 7606-0
Fax +49 3764 7606-30 [email protected]
Tel. +49 89 909552-10
Fax +49 89 909552-50 [email protected]
Tel. +49 2173 8507-30
Fax +49 2173 8507-55 [email protected]
+49 180 5 SEWHELP
+49 180 5 7394357
France
Production
Sales
Service
Assembly
Sales
Service
Haguenau
Bordeaux
SEW-USOCOME
48-54, route de Soufflenheim
B. P. 20185
F-67506 Haguenau Cedex
SEW-USOCOME
Parc d'activités de Magellan
62, avenue de Magellan - B. P. 182
F-33607 Pessac Cedex
Lyon
Paris
SEW-USOCOME
Parc d'Affaires Roosevelt
Rue Jacques Tati
F-69120 Vaulx en Velin
SEW-USOCOME
Zone industrielle
2, rue Denis Papin
F-77390 Verneuil I'Etang
Additional addresses for service in France provided on request!
Tel. +33 3 88 73 67 00
Fax +33 3 88 73 66 00 http://www.usocome.com
Tel. +33 5 57 26 39 00
Fax +33 5 57 26 39 09
Tel. +33 4 72 15 37 00
Fax +33 4 72 15 37 15
Tel. +33 1 64 42 40 80
Fax +33 1 64 42 40 88
Algeria
Sales Alger
Réducom
16, rue des Frères Zaghnoun
Bellevue El-Harrach
16200 Alger
Tel. +213 21 8222-84
Fax +213 21 8222-84
Argentina
Assembly
Sales
Service
Buenos Aires
SEW EURODRIVE ARGENTINA S.A.
Centro Industrial Garin, Lote 35
Ruta Panamericana Km 37,5
1619 Garin
Tel. +54 3327 4572-84
Fax +54 3327 4572-21 [email protected]
Address List
Australia
Assembly
Sales
Service
Austria
Assembly
Sales
Service
Belgium
Assembly
Sales
Service
Brazil
Production
Sales
Service
Bulgaria
Sales
Cameroon
Sales
Canada
Assembly
Sales
Service
Chile
Assembly
Sales
Service
Melbourne
Sydney
Townsville
Wien
Brüssel
SEW-EURODRIVE PTY. LTD.
27 Beverage Drive
Tullamarine, Victoria 3043
SEW-EURODRIVE PTY. LTD.
9, Sleigh Place, Wetherill Park
New South Wales, 2164
SEW-EURODRIVE PTY. LTD.
12 Leyland Street
Garbutt, QLD 4814
SEW-EURODRIVE Ges.m.b.H.
Richard-Strauss-Strasse 24
A-1230 Wien
SEW Caron-Vector S.A.
Avenue Eiffel 5
B-1300 Wavre
Tel. +61 3 9933-1000
Fax +61 3 9933-1003 http://www.sew-eurodrive.com.au
Tel. +61 2 9725-9900
Fax +61 2 9725-9905 [email protected]
Tel. +61 7 4779 4333
Fax +61 7 4779 5333 [email protected]
Tel. +43 1 617 55 00-0
Fax +43 1 617 55 00-30 http://sew-eurodrive.at
Tel. +32 10 231-311
Fax +32 10 231-336 http://www.caron-vector.be
Tel. +55 11 6489-9133
Fax +55 11 6480-3328 http://www.sew.com.br
Sao Paulo
SEW-EURODRIVE Brasil Ltda.
Avenida Amâncio Gaiolli, 50
Caixa Postal: 201-07111-970
Guarulhos/SP - Cep.: 07251-250
Additional addresses for service in Brazil provided on request!
Sofia
Douala
BEVER-DRIVE GmbH
Bogdanovetz Str.1
BG-1606 Sofia
Electro-Services
Rue Drouot Akwa
B.P. 2024
Douala
Tel. +359 2 9151160
Fax +359 2 9151166 [email protected]
Tel. +237 4322-99
Fax +237 4277-03
Toronto
SEW-EURODRIVE CO. OF CANADA LTD.
210 Walker Drive
Bramalea, Ontario L6T3W1
Vancouver
Montreal
SEW-EURODRIVE CO. OF CANADA LTD.
7188 Honeyman Street
Delta. B.C. V4G 1 E2
SEW-EURODRIVE CO. OF CANADA LTD.
2555 Rue Leger Street
LaSalle, Quebec H8N 2V9
Additional addresses for service in Canada provided on request!
Tel. +1 905 791-1553
Fax +1 905 791-2999 http://www.sew-eurodrive.ca
Tel. +1 604 946-5535
Fax +1 604 946-2513 [email protected]
Tel. +1 514 367-1124
Fax +1 514 367-3677 [email protected]
Santiago de
Chile
SEW-EURODRIVE CHILE LTDA.
Las Encinas 1295
Parque Industrial Valle Grande
LAMPA
RCH-Santiago de Chile
P.O. Box
Casilla 23 Correo Quilicura - Santiago - Chile
Tel. +56 2 75770-00
Fax +56 2 75770-01 www.sew-eurodrive.cl
37
38
Address List
China
Production
Assembly
Sales
Service
Assembly
Sales
Service
Tianjin
SEW-EURODRIVE (Tianjin) Co., Ltd.
No. 46, 7th Avenue, TEDA
Tianjin 300457
Suzhou
SEW-EURODRIVE (Suzhou) Co., Ltd.
333, Suhong Middle Road
Suzhou Industrial Park
Jiangsu Province, 215021
P. R. China
Additional addresses for service in China provided on request!
Colombia
Assembly
Sales
Service
Croatia
Sales
Service
Czech Republic
Sales
Bogotá
Zagreb
Praha
SEW-EURODRIVE COLOMBIA LTDA.
Calle 22 No. 132-60
Bodega 6, Manzana B
Santafé de Bogotá
KOMPEKS d. o. o.
PIT Erdödy 4 II
HR 10 000 Zagreb
SEW-EURODRIVE CZ S.R.O.
Business Centrum Praha
Luzna 591
CZ-16000 Praha 6 - Vokovice
Denmark
Assembly
Sales
Service
Estonia
Sales
Kopenhagen
Tallin
SEW-EURODRIVEA/S
Geminivej 28-30, P.O. Box 100
DK-2670 Greve
ALAS-KUUL AS
Mustamäe tee 24
EE-10620Tallin
Finland
Assembly
Sales
Service
Gabon
Sales
Lahti
Libreville
SEW-EURODRIVE OY
Vesimäentie 4
FIN-15860 Hollola 2
Electro-Services
B.P. 1889
Libreville
Great Britain
Assembly
Sales
Service
Greece
Sales
Service
Normanton
Athen
SEW-EURODRIVE Ltd.
Beckbridge Industrial Estate
P.O. Box No.1
GB-Normanton, West- Yorkshire WF6 1QR
Christ. Boznos & Son S.A.
12, Mavromichali Street
P.O. Box 80136, GR-18545 Piraeus
Tel. +86 22 25322612
Fax +86 22 25322611 [email protected]
http://www.sew-eurodrive.com.cn
Tel. +86 512 62581781
Fax +86 512 62581783 [email protected]
Tel. +57 1 54750-50
Fax +57 1 54750-44 http://www.sew-eurodrive.com.co
Tel. +385 1 4613-158
Fax +385 1 4613-158 [email protected]
Tel. +420 220121234
Fax +420 220121237 http://www.sew-eurodrive.cz
Tel. +45 43 9585-00
Fax +45 43 9585-09 http://www.sew-eurodrive.dk
Tel. +372 6593230
Fax +372 6593231 [email protected]
Tel. +358 201 589-300
Fax +358 3 780-6211 [email protected]
http://www.sew-eurodrive.fi
Tel. +241 7340-11
Fax +241 7340-12
Tel. +44 1924 893-855
Fax +44 1924 893-702 http://www.sew-eurodrive.co.uk
Tel. +30 2 1042 251-34
Fax +30 2 1042 251-59 http://www.boznos.gr
Address List
Japan
Assembly
Sales
Service
Korea
Assembly
Sales
Service
Latvia
Sales
Hong Kong
Assembly
Sales
Service
Hungary
Sales
Service
Ireland
Sales
Service
Israel
Sales
Italy
Assembly
Sales
Service
Ivory Coast
Sales
Hong Kong
Budapest
India
Assembly
Sales
Service
Technical Offices
Baroda
Bangalore
Dublin
Tel-Aviv
Milano
Abidjan
Toyoda-cho
Ansan-City
Riga
SEW-EURODRIVE LTD.
Unit No. 801-806, 8th Floor
Hong Leong Industrial Complex
No. 4, Wang Kwong Road
Kowloon, Hong Kong
SEW-EURODRIVE Kft.
H-1037 Budapest
Kunigunda u. 18
SEW-EURODRIVE India Pvt. Ltd.
Plot No. 4, Gidc
Por Ramangamdi • Baroda - 391 243
Gujarat
SEW-EURODRIVE India Private Limited
308, Prestige Centre Point
7, Edward Road
Bangalore
Tel. +852 2 7960477 + 79604654
Fax +852 2 7959129 [email protected]
Tel. +36 1 437 06-58
Fax +36 1 437 06-50 [email protected]
Tel. +91 265 2831086
Fax +91 265 2831087 http://www.seweurodriveindia.com
Tel. +91 80 22266565
Fax +91 80 22266569 [email protected]
Alperton Engineering Ltd.
48 Moyle Road
Dublin Industrial Estate
Glasnevin, Dublin 11
Liraz Handasa Ltd.
Ahofer Str 34B / 228
58858 Holon
Tel. +353 1 830-6277
Fax +353 1 830-6458
Tel. +972 3 5599511
Fax +972 3 5599512 [email protected]
SEW-EURODRIVE di R. Blickle & Co.s.a.s.
Via Bernini,14
I-20020 Solaro (Milano)
Tel. +39 02 96 9801
Fax +39 02 96 799781 http://www.sew-eurodrive.it
SICA
Ste industrielle et commerciale pour l'Afrique
165, Bld de Marseille
B.P. 2323, Abidjan 08
Tel. +225 2579-44
Fax +225 2584-36
Tel. +81 538 373811
Fax +81 538 373814 [email protected]
SEW-EURODRIVE JAPAN CO., LTD
250-1, Shimoman-no,
Iwata
Shizuoka 438-0818
SEW-EURODRIVE KOREA CO., LTD.
B 601-4, Banweol Industrial Estate
Unit 1048-4, Shingil-Dong
Ansan 425-120
SIA Alas-Kuul
Katlakalna 11C
LV-1073 Riga
Tel. +82 31 492-8051
Fax +82 31 492-8056 http://www.sew-korea.co.kr
Tel. +371 7139253
Fax +371 7139386 http://www.alas-kuul.com
39
40
Address List
Lebanon
Sales
Lithuania
Sales
Luxembourg
Assembly
Sales
Service
Malaysia
Assembly
Sales
Service
Mexico
Assembly
Sales
Service
Morocco
Sales
Netherlands
Assembly
Sales
Service
New Zealand
Assembly
Sales
Service
Norway
Assembly
Sales
Service
Peru
Assembly
Sales
Service
Beirut
Alytus
Brüssel
Gabriel Acar & Fils sarl
B. P. 80484
Bourj Hammoud, Beirut
UAB Irseva
Naujoji 19
LT-62175 Alytus
CARON-VECTOR S.A.
Avenue Eiffel 5
B-1300 Wavre
Tel. +961 1 4947-86
+961 1 4982-72
+961 3 2745-39
Fax +961 1 4949-71 [email protected]
Tel. +370 315 79204
Fax +370 315 56175 [email protected]
http://www.sew-eurodrive.lt
Tel. +32 10 231-311
Fax +32 10 231-336 http://www.caron-vector.be
Johore
Queretaro
Casablanca
SEW-EURODRIVE SDN BHD
No. 95, Jalan Seroja 39, Taman Johor Jaya
81000 Johor Bahru, Johor
West Malaysia
Tel. +60 7 3549409
Fax +60 7 3541404 [email protected]
SEW-EURODRIVE MEXIKO SA DE CV
SEM-981118-M93
Tequisquiapan No. 102
Parque Industrail Queretaro
C.P. 76220
Queretaro, Mexico
Afit
5, rue Emir Abdelkader
MA 20300 Casablanca
Tel. +52 442 1030-300
Fax +52 442 1030-301 http://www.sew-eurodrive.com.mx
Tel. +212 22618372
Fax +212 22618351 [email protected]
Tel. +31 10 4463-700
Fax +31 10 4155-552 http://www.vector.nu
Rotterdam
VECTOR Aandrijftechniek B.V.
Industrieweg 175
NL-3044 AS Rotterdam
Postbus 10085
NL-3004 AB Rotterdam
Auckland
Christchurch
SEW-EURODRIVE NEW ZEALAND LTD.
P.O. Box 58-428
82 Greenmount drive
East Tamaki Auckland
SEW-EURODRIVE NEW ZEALAND LTD.
10 Settlers Crescent, Ferrymead
Christchurch
Moss
SEW-EURODRIVE A/S
Solgaard skog 71
N-1599 Moss
Tel. +64 9 2745627
Fax +64 9 2740165 http://www.sew-eurodrive.co.nz
Tel. +64 3 384-6251
Fax +64 3 384-6455 [email protected]
Tel. +47 69 241-020
Fax +47 69 241-040 http://www.sew-eurodrive.no
Lima
SEW DEL PERU MOTORES REDUCTORES
S.A.C.
Los Calderos, 120-124
Urbanizacion Industrial Vulcano, ATE, Lima
Tel. +51 1 3495280
Fax +51 1 3493002 http://www.sew-eurodrive.com.pe
Address List
Poland
Assembly
Sales
Service
Portugal
Assembly
Sales
Service
Romania
Sales
Service
Russia
Assembly
Sales
Service
Senegal
Sales
Sales
Singapore
Assembly
Sales
Service
Slovakia
Sales
Slovenia
Sales
Service
South Africa
Assembly
Sales
Service
Lodz
Coimbra
Bucuresti
Dakar
Serbia and Montenegro
Beograd
Singapore
Celje
SEW-EURODRIVE Polska Sp.z.o.o.
ul. Techniczna 5
PL-92-518 Lodz
SEW-EURODRIVE, LDA.
Apartado 15
P-3050-901 Mealhada
Sialco Trading SRL str. Madrid nr.4
011785 Bucuresti
St. Petersburg
ZAO SEW-EURODRIVE
P.O. Box 36
195220 St. Petersburg Russia
SENEMECA
Mécanique Générale
Km 8, Route de Rufisque
B.P. 3251, Dakar
DIPAR d.o.o.
Ustanicka 128a
PC Košum, IV floor
SCG-11000 Beograd
SEW-EURODRIVE PTE. LTD.
No 9, Tuas Drive 2
Jurong Industrial Estate
Singapore 638644
Bratislava
SEW-Eurodrive SK s.r.o.
Rybnicna 40
SK-83107 Bratislava
Zilina
SEW-Eurodrive SK s.r.o.
ul. Vojtecha Spanyola 33
SK-010 01 Zilina
Banská Bystrica
SEW-Eurodrive SK s.r.o.
Rudlovská cesta 85
SK-97411 Banská Bystrica
Pakman - Pogonska Tehnika d.o.o.
UI. XIV. divizije 14
SLO - 3000 Celje
Tel. +48 42 67710-90
Fax +48 42 67710-99 http://www.sew-eurodrive.pl
Tel. +351 231 20 9670
Fax +351 231 20 3685 http://www.sew-eurodrive.pt
Tel. +40 21 230-1328
Fax +40 21 230-7170 [email protected]
Tel. +7 812 3332522 +7 812 5357142
Fax +7 812 3332523 http://www.sew-eurodrive.ru
Tel. +221 849 47-70
Fax +221 849 47-71 [email protected]
Tel. +381 11 347 3244 / +381 11 288
0393
Fax +381 11 347 1337 [email protected]
Tel. +65 68621701
Fax +65 68612827 http://www.sew-eurodrive.com.sg
Tel. +421 2 49595201
Fax +421 2 49595200 http://www.sew.sk
Tel. +421 41 700 2513
Fax +421 41 700 2514 [email protected]
Tel. +421 48 414 6564
Fax +421 48 414 6566 [email protected]
Tel. +386 3 490 83-20
Fax +386 3 490 83-21 [email protected]
Johannesburg
SEW-EURODRIVE (PROPRIETARY) LIMITED
Eurodrive House
Cnr. Adcock Ingram and Aerodrome Roads
Aeroton Ext. 2
Johannesburg 2013
P.O.Box 90004
Bertsham 2013
Tel. +27 11 248-7000
Fax +27 11 494-3104 http://www.sew.co.za
41
42
Address List
South Africa
Spain
Assembly
Sales
Service
Sweden
Assembly
Sales
Service
Switzerland
Assembly
Sales
Service
Thailand
Assembly
Sales
Service
Tunisia
Sales
Turkey
Assembly
Sales
Service
Ukraine
Sales
Service
USA
Production
Assembly
Sales
Service
Capetown
Durban
Bilbao
Jönköping
Basel
Chon Buri
SEW-EURODRIVE (PROPRIETARY) LIMITED
Rainbow Park
Cnr. Racecourse & Omuramba Road
Montague Gardens
Cape Town
P.O.Box 36556
Chempet 7442
Cape Town
SEW-EURODRIVE (PROPRIETARY) LIMITED
2 Monaceo Place
Pinetown
Durban
P.O. Box 10433, Ashwood 3605
Tel. +27 21 552-9820
Fax +27 21 552-9830
Telex 576 062 [email protected]
Tel. +27 31 700-3451
Fax +27 31 700-3847 [email protected]
SEW-EURODRIVE ESPAÑA, S.L.
Parque Tecnológico, Edificio, 302
E-48170 Zamudio (Vizcaya)
SEW-EURODRIVE AB
Gnejsvägen 6-8
S-55303 Jönköping
Box 3100 S-55003 Jönköping
Alfred lmhof A.G.
Jurastrasse 10
CH-4142 Münchenstein bei Basel
Tel. +34 9 4431 84-70
Fax +34 9 4431 84-71 http://www.sew-eurodrive.es
Tel. +46 36 3442-00
Fax +46 36 3442-80 http://www.sew-eurodrive.se
SEW-EURODRIVE (Thailand) Ltd.
Bangpakong Industrial Park 2
700/456, Moo.7, Tambol Donhuaroh
Muang District
Chon Buri 20000
Tel. +41 61 417 1717
Fax +41 61 417 1700 http://www.imhof-sew.ch
Tel. +66 38 454281
Fax +66 38 454288 [email protected]
Tel. +216 1 4340-64 + 1 4320-29
Fax +216 1 4329-76 [email protected]
Tunis
Istanbul
T. M.S. Technic Marketing Service
7, rue Ibn EI Heithem
Z.I. SMMT
2014 Mégrine Erriadh
SEW-EURODRIVE
Hareket Sistemleri San. ve Tic. Ltd. Sti.
Bagdat Cad. Koruma Cikmazi No. 3
TR-34846 Maltepe ISTANBUL
Dnepropetrovsk
SEW-EURODRIVE
Str. Rabochaja 23-B, Office 409
49008 Dnepropetrovsk
Tel. +90 216 4419163 / 164 3838014/15
Fax +90 216 3055867 [email protected]
Greenville
SEW-EURODRIVE INC.
1295 Old Spartanburg Highway
P.O. Box 518
Lyman, S.C. 29365
Tel. +380 56 370 3211
Fax +380 56 372 2078 http://www.sew-eurodrive.ua
Tel. +1 864 439-7537
Fax Sales +1 864 439-7830
Fax Manuf. +1 864 439-9948
Fax Ass. +1 864 439-0566
Telex 805 550 http://www.seweurodrive.com
Address List
USA
Assembly
Sales
Service
Venezuela
Assembly
Sales
Service
San Francisco
Philadelphia/PA
SEW-EURODRIVE INC.
Pureland Ind. Complex
2107 High Hill Road, P.O. Box 481
Bridgeport, New Jersey 08014
Dayton
SEW-EURODRIVE INC.
30599 San Antonio St.
Hayward, California 94544-7101
SEW-EURODRIVE INC.
2001 West Main Street
Troy, Ohio 45373
Dallas
SEW-EURODRIVE INC.
3950 Platinum Way
Dallas, Texas 75237
Additional addresses for service in the USA provided on request!
Tel. +1 510 487-3560
Fax +1 510 487-6381 [email protected]
Tel. +1 856 467-2277
Fax +1 856 845-3179 [email protected]
Tel. +1 937 335-0036
Fax +1 937 440-3799 [email protected]
Tel. +1 214 330-4824
Fax +1 214 330-4724 [email protected]
Valencia
SEW-EURODRIVE Venezuela S.A.
Av. Norte Sur No. 3, Galpon 84-319
Zona Industrial Municipal Norte
Valencia, Estado Carabobo
Tel. +58 241 832-9804
Fax +58 241 838-6275 http://www.sew-eurodrive.com.ve
43
Gearmotors \ Industrial Gear Units \ Drive Electronics \ Drive Automation \ Services
How we’re driving the world
With people who think fast and develop the future with you.
With a worldwide service network that is always close at hand.
With drives and controls that automatically improve your productivity.
With comprehensive knowledge in virtually every branch of industry today.
With uncompromising quality that reduces the cost and complexity of daily operations.
With a global presence that offers responsive and reliable solutions.
Anywhere.
With innovative technology that solves tomorrow’s problems today.
With online information and software updates, via the Internet, available around the clock.
SEW-EURODRIVE
Driving the world
SEW-EURODRIVE GmbH & Co KG
P.O. Box 3023 · D-76642 Bruchsal / Germany
Phone +49 7251 75-0 · Fax +49 7251 75-1970 [email protected]
www.sew-eurodrive.com
advertisement
Key Features
- Decentralized field control
- Gateway functionality
- ProfiBus communication
- 24V brake control system
- MOVIDRIVE® MCS20A-0040 drive inverter
Frequently Answers and Questions
What is the PHC11A-A040M1-P00K-01's function level?
What communication medium does the PHC11A-A040M1-P00K-01 use?
What is the maximum motor cable length for the PHC11A-A040M1-P00K-01?
What is the operating voltage range for the PHC11A-A040M1-P00K-01?
Related manuals
advertisement
Table of contents
- 4 1 Important Notes
- 6 2 Safety Notes
- 8 3 Unit Design
- 8 Nameplate
- 9 Unit designation
- 10 Scope of delivery
- 12 Unit design
- 12 Operating principle
- 13 Power electronics
- 14 Control technology
- 15 4 Installation
- 15 Installation notes
- 21 Connections
- 21 Wiring diagrams
- 26 5 Startup
- 26 General notes
- 26 Motors and brakes
- 27 6 Operation and Service
- 27 Operating notes
- 28 Fault information
- 30 Shut down
- 30 Transportation
- 30 Storage
- 30 Maintenance
- 31 7 Technical Data
- 31 PHC11A
- 33 Dimension drawing
- 33 Additional information
- 34 8 Index