Advertisement
Advertisement
29.12.2005 Nokeval Oy User Manual DCS772 USB-POL converter 1 Introduction With DCS772 you can add a POL interface to your PC. POL interface is used to setup Nokeval devices supporting POL interface. DCS772 is connected to PCs USB port. Drivers of DCS772 will create a virtual serial port, which can be used as common serial port. Baud rates and amount of bits are selected in Windows Control Panel or directly from your application. DCS772 is used only for configuration. For trouble shooting there is three LEDs on DCS772. 2 Technical data 2.1 USB-interface Interface: USB circuit: Current : Connector: 2.2 USB 1.1 or 2.0 FTDI FT232BM < 100 mA USB-B (USB-A-B cable included). POL-interface Baudrates: Bus length: Connector: 300…9600 bit/s max. 1 m 3.5mm mono jack (cable included) 3 Installation USB circuit of the DCS772 needs two drivers to be installed to PC. First driver is used to create USB connection between PC and converter. Second driver is used to create Virtual Serial Port. Drivers can be installed from Nokeval Software CD or download the latest drivers from manufacturer of the interface circuit www.ftdichip.com (Drivers, FT232BM). Instructions below show how to install drivers from CD. But you can adapt instructions also for downloaded drivers. Put Nokeval Software CD to your CD-drive and connect DCS772 to USB port. Windows should recognice a new device and start driver installation automaticly. 2.3 Miscellaneous Size: Ambient tempereture: Galvanic isolation: 2.4 2.4.1 EMC EMC immunity EN 61326 2.4.2 EMC emissions EN 61326 class B 56x31x25 mm 0...60 °C No When USB-Driver (ftdibus.inf) is installed, Windows will install VirtualSerialPort-Driver. Install VirtualSerialPort-Driver same way as USB-driver. OK-LED of converter should turn ON. Now you have to find out which COM port is assosiated for the converter. Open Control Panel / System / Hardware / Device Manager. From Device tree open Ports. There should be a line for each converter. For example USB Serial Port (COM3). 3 4 Troubleshooting LEDs of DCS772 are very useful in troubleshooting wrong in your application setup. Probably wrong serial port. 4.1 4.3 Step 1: Drivers If OK-LED id OFF, install drivers. 4.2 Step 2: Transmission Start your application on PC and check if TxLED if blinking. If not there is something Step 3: Receiving If Rx-LED if blinking simultaneously with TxLED, but not alone. This means your POL device is not responding. Check your device is powered up and serial communication settings are correct. Nokeval Oy Yrittäjäkatu 12 37100 Nokia Finland Puh. 03-3424800 Fax. 03.3422066 Email: [email protected] http: www.nokeval.com 4 ">
Advertisement