Digidim Remote Control (303) Installation and User Guide


Add to my manuals
5 Pages

advertisement

Digidim Remote Control (303) Installation and User Guide | Manualzz

Installation and User Guide

Digidim Remote Control (303)

Product description

The Digidim Remote (303) can be used in conjunction with the iDim Sense to modify the preset light levels and recall/ store scenes, as well as activating its special functions (100 h Burn-In, PIR Walk test and Mode Identification).

A. LED Indicator (Flashes as each message is transmitted)

B. Scene Recall/Configuration

C. On/Off/Shift

D. Modifier Keys

E. Transmitter

F. Battery Cover

Switching Lights On/Off using Digidim 303 Remote

To switch the lights On or Off:

1.1 Point the remote control at a controller

1.2 Press On/Off/Shift key on remote control to switch the

lights on or off

Note: Throughout this document ‘Controller’ refers to iDim

Sense and/or Button Panels.

3

4

1

2

Recall Scenes using Digidim 303 Remote

7

O

5

6

0 %

0/1

To recall a scene using the DIGIDIM remote:

2.1 Point the remote control at a controller

2.2 Press scene key 1, 2, 3 or 4 to recall scene

1

2

3

4

5

6

7

O

1

+

2

Modify Light Levels using Digidim 303 Remote

To modify DALI 1 light levels using the DIGIDIM remote:

3.1 Point the remote control at a controller

3.2 Press scene 1 + Up modifier key to raise DALI 1 light level

3.3 Press scene 1 + Down modifier key to lower DALI 1 light level

Note: To store scenes see chapter 4

1

2

3

4

5

6

7

O

To modify DALI 2 light levels using the DIGIDIM remote:

3.4 Point the remote control at a controller

3.5 Press scene 2 + Up modifier key to raise DALI 2 light level

3.6 Press scene 2 + Down modifier key to lower DALI 2 light level

1

3

2

4

5

6

7

O

1

+

1

+

+

2

+

+

2

+

3 4

1 %

DALI 1

100 %

100 % 1 %

1 %

DALI 2

100 %

100 % 1 %

Helvar | Data is subject to change without notice.

www.helvar.com i

Contents

Section Page

Product description

Switching Lights On/Off using Digidim 303 Remote

Recall Scenes using Digidim 303 Remote

Modify Light Levels using Digidim 303 Remote

Store Scenes using Digidim 303 Remote

Special Functions using Digidim 303 Remote

LED Flash Feedback

Technical Data

1

1 i i i i

2

3 ii Helvar | Data is subject to change without notice.

www.helvar.com

Store Scenes using Digidim 303 Remote

To store a modified scene using the DIGIDIM remote:

4.1 Point the remote control at a controller

4.2 Hold scene key 1, 2, 3 or 4 for 10 seconds to store scene. iDim Sense LEDs will flash green if successful.

3

4

1

2

7

O

5

6

10 s

1

10 s

+

2

10 s

3

10 s

4

Note: See LED Feedback table on final page of this document

for LED information.

Special Functions using Digidim 303 Remote

Start/Stop 100 hour Burn-In Mode

To start or stop Burn-In mode:

5.1 Point the remote control at a controller

5.2 Press On/Off/Shift key and scene 1 at same time

1

2

3

4

5

7

6

O

Note: Restarting a Burn-In test following a stop will cause the 100 hour counter to restart from 0. Use

Resume sBurn-In Mode to continue a stopped Burn-In test.

See instruction 5.3 below for information how to do this.

Resume Burn-In Mode

To resume a stopped Burn-In mode at a later date:

5.3 Point the remote control at a controller

5.4 Press On/Off/Shift key and scene 2

Note: If a Power Off/On cycle occurs, the counter will be reset to 0.

Mode Identification

To establish which iDim Sense mode is selected:

5.5 Point the remote control at a controller

5.6 Press On/Off/Shift key and scene 3

3

4

1

2

7

5

6

O

Start/Stop PIR Walk Test

5.7 Point the remote control at a controller

5.8 Press On/Off/Shift key and scene 4

1

2

3

4

5

6

7

O

1

0/1

+

250 ms

250 ms

250 ms

250 ms iDim Sense LED Feedback

...

+

2

0/1

+

...

250 ms

250 ms

250 ms iDim Sense LED Feedback

...

0/1

+

3

250 ms iDim Sense LED Feedback

3

4

1

2

5

6

7

O

Note: Number of flashes depends on

mode selected. See overleaf for

detailed LED information

0/1

+

4

1 sec 1 sec

...

iDim Sense LED Feedback

1 Helvar 303 Remote Control iDIM: Installation and User Guide Doc. D004744 issue 5,

2014-08-28

LED Flash Feedback

Two LEDs, red and green, located in the iDim Sense flash to provide visual feedback for various states.

Function

User Defined Mode Selected

Following an upload from IR Remote

Mode 1 Selected

(Classroom)

Mode 2 Selected

(Single Office)

Mode 3 Selected

(Open Plan Office)

Mode 4 Selected

(Corridor Link)

Mode 5 Selected

(Corridor Hold)

Mode 6 Selected

(Meeting Room)

PIR Walk Test Mode

Sequence repeats until walk test is complete

100 hour Burn-In Mode

Sequence repeats until burn-in is complete

DALI Errors

Sequence repeats until error clears

LED Flash Feedback

250 ms

250 ms

250 ms

250 ms

250 ms

250 ms

250 ms

250 ms

Change from unoccupied to occupied

Typically follows a PIR detection

Data received from IR Remote

125 ms

Re-enabling of IR Remote 1.

125 ms

Successful upload from IR Remote 1.

Visible after storing modified settings

Failed upload from IR Remote 1.

Visible when modified settings upload fails

1. Excluded from use with DIGIDIM 303 Remote Control

625 ms

625 ms

250 ms

250 ms

250 ms

250 ms

250 ms

250 ms

250 ms

250 ms

250 ms

250 ms

250 ms

250 ms

250 ms

250 ms

1 sec

250 ms

250 ms

250 ms

250 ms

1 sec

250 ms

250 ms

250 ms

250 ms

250 ms

250 ms

1 sec

250 ms

...

250 ms

...

250 ms

250 ms

250 ms

125 ms

125 ms

125 ms

125 ms

125 ms

125 ms

125 ms

125 ms

125 ms

2 Helvar 303 Remote Control iDIM: Installation and User Guide Doc. D004744 issue 5,

2014-08-28

Technical Data

Connections

No external physical connections are necessary

Power

Power supply: 2 × IEC, LR03/AAA 1.5 V

Battery

Range

Operating range: Approximately 5 m: with

± 22.5°angle to panels with

± 63° angle to multisensors

Operation

IR frequency:

Mechanical data

Dimensions:

Housing:

36 kHz

57 mm × 28 mm × 119 mm

Matt dark grey, nonflammable polycarbonate, halogen free

50 g Weight:

Operating conditions

Ambient temperature:

Relative humidity:

0 °C to +40 °C

Max. 90 %, non-condensing

Storage temperature:

Conformity and standards

–10 °C to +70 °C

Environment: Complies with WEEE and

RoHS directives

3 Helvar 303 Remote Control iDIM: Installation and User Guide Doc. D004744 issue 5,

2014-08-28

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

advertisement