- No category
advertisement
Installation and User Guide
Digidim Remote Control (303)
Product description
The Digidim Remote (303) can be used in conjunction with the iDim Sense to modify the preset light levels and recall/ store scenes, as well as activating its special functions (100 h Burn-In, PIR Walk test and Mode Identification).
A. LED Indicator (Flashes as each message is transmitted)
B. Scene Recall/Configuration
C. On/Off/Shift
D. Modifier Keys
E. Transmitter
F. Battery Cover
Switching Lights On/Off using Digidim 303 Remote
To switch the lights On or Off:
1.1 Point the remote control at a controller
1.2 Press On/Off/Shift key on remote control to switch the
lights on or off
Note: Throughout this document ‘Controller’ refers to iDim
Sense and/or Button Panels.
3
4
1
2
Recall Scenes using Digidim 303 Remote
7
O
5
6
0 %
0/1
To recall a scene using the DIGIDIM remote:
2.1 Point the remote control at a controller
2.2 Press scene key 1, 2, 3 or 4 to recall scene
1
2
3
4
5
6
7
O
1
+
2
Modify Light Levels using Digidim 303 Remote
To modify DALI 1 light levels using the DIGIDIM remote:
3.1 Point the remote control at a controller
3.2 Press scene 1 + Up modifier key to raise DALI 1 light level
3.3 Press scene 1 + Down modifier key to lower DALI 1 light level
Note: To store scenes see chapter 4
1
2
3
4
5
6
7
O
To modify DALI 2 light levels using the DIGIDIM remote:
3.4 Point the remote control at a controller
3.5 Press scene 2 + Up modifier key to raise DALI 2 light level
3.6 Press scene 2 + Down modifier key to lower DALI 2 light level
1
3
2
4
5
6
7
O
1
+
1
+
+
2
+
+
2
+
3 4
1 %
DALI 1
100 %
100 % 1 %
1 %
DALI 2
100 %
100 % 1 %
Helvar | Data is subject to change without notice.
www.helvar.com i
Contents
Section Page
Product description
Switching Lights On/Off using Digidim 303 Remote
Recall Scenes using Digidim 303 Remote
Modify Light Levels using Digidim 303 Remote
Store Scenes using Digidim 303 Remote
Special Functions using Digidim 303 Remote
LED Flash Feedback
Technical Data
1
1 i i i i
2
3 ii Helvar | Data is subject to change without notice.
www.helvar.com
Store Scenes using Digidim 303 Remote
To store a modified scene using the DIGIDIM remote:
4.1 Point the remote control at a controller
4.2 Hold scene key 1, 2, 3 or 4 for 10 seconds to store scene. iDim Sense LEDs will flash green if successful.
3
4
1
2
7
O
5
6
10 s
1
10 s
+
2
10 s
3
10 s
4
Note: See LED Feedback table on final page of this document
for LED information.
Special Functions using Digidim 303 Remote
Start/Stop 100 hour Burn-In Mode
To start or stop Burn-In mode:
5.1 Point the remote control at a controller
5.2 Press On/Off/Shift key and scene 1 at same time
1
2
3
4
5
7
6
O
Note: Restarting a Burn-In test following a stop will cause the 100 hour counter to restart from 0. Use
Resume sBurn-In Mode to continue a stopped Burn-In test.
See instruction 5.3 below for information how to do this.
Resume Burn-In Mode
To resume a stopped Burn-In mode at a later date:
5.3 Point the remote control at a controller
5.4 Press On/Off/Shift key and scene 2
Note: If a Power Off/On cycle occurs, the counter will be reset to 0.
Mode Identification
To establish which iDim Sense mode is selected:
5.5 Point the remote control at a controller
5.6 Press On/Off/Shift key and scene 3
3
4
1
2
7
5
6
O
Start/Stop PIR Walk Test
5.7 Point the remote control at a controller
5.8 Press On/Off/Shift key and scene 4
1
2
3
4
5
6
7
O
1
0/1
+
250 ms
250 ms
250 ms
250 ms iDim Sense LED Feedback
...
+
2
0/1
+
...
250 ms
250 ms
250 ms iDim Sense LED Feedback
...
0/1
+
3
250 ms iDim Sense LED Feedback
3
4
1
2
5
6
7
O
Note: Number of flashes depends on
mode selected. See overleaf for
detailed LED information
0/1
+
4
1 sec 1 sec
...
iDim Sense LED Feedback
1 Helvar 303 Remote Control iDIM: Installation and User Guide Doc. D004744 issue 5,
2014-08-28
LED Flash Feedback
Two LEDs, red and green, located in the iDim Sense flash to provide visual feedback for various states.
Function
User Defined Mode Selected
Following an upload from IR Remote
Mode 1 Selected
(Classroom)
Mode 2 Selected
(Single Office)
Mode 3 Selected
(Open Plan Office)
Mode 4 Selected
(Corridor Link)
Mode 5 Selected
(Corridor Hold)
Mode 6 Selected
(Meeting Room)
PIR Walk Test Mode
Sequence repeats until walk test is complete
100 hour Burn-In Mode
Sequence repeats until burn-in is complete
DALI Errors
Sequence repeats until error clears
LED Flash Feedback
250 ms
250 ms
250 ms
250 ms
250 ms
250 ms
250 ms
250 ms
Change from unoccupied to occupied
Typically follows a PIR detection
Data received from IR Remote
125 ms
Re-enabling of IR Remote 1.
125 ms
Successful upload from IR Remote 1.
Visible after storing modified settings
Failed upload from IR Remote 1.
Visible when modified settings upload fails
1. Excluded from use with DIGIDIM 303 Remote Control
625 ms
625 ms
250 ms
250 ms
250 ms
250 ms
250 ms
250 ms
250 ms
250 ms
250 ms
250 ms
250 ms
250 ms
250 ms
250 ms
1 sec
250 ms
250 ms
250 ms
250 ms
1 sec
250 ms
250 ms
250 ms
250 ms
250 ms
250 ms
1 sec
250 ms
...
250 ms
...
250 ms
250 ms
250 ms
125 ms
125 ms
125 ms
125 ms
125 ms
125 ms
125 ms
125 ms
125 ms
2 Helvar 303 Remote Control iDIM: Installation and User Guide Doc. D004744 issue 5,
2014-08-28
Technical Data
Connections
No external physical connections are necessary
Power
Power supply: 2 × IEC, LR03/AAA 1.5 V
Battery
Range
Operating range: Approximately 5 m: with
± 22.5°angle to panels with
± 63° angle to multisensors
Operation
IR frequency:
Mechanical data
Dimensions:
Housing:
36 kHz
57 mm × 28 mm × 119 mm
Matt dark grey, nonflammable polycarbonate, halogen free
50 g Weight:
Operating conditions
Ambient temperature:
Relative humidity:
0 °C to +40 °C
Max. 90 %, non-condensing
Storage temperature:
Conformity and standards
–10 °C to +70 °C
Environment: Complies with WEEE and
RoHS directives