3.Dimensions
1.Description of Function
LATshine series solar controller is specifically designed to meet the needs of solar home systems. It provides the best cost-effective.
It comes with a number of outstanding features, such as:
● Low cost and high reliability design
● 12V/24V automatic recognition
● Clear readable display of charge/discharge and error description
●
●
Temperature compensation
Four stage charge way: fast, boost, equalization, float
● Full automatic electronic protect function
4.Installation
The following diagrams provide an overview of the connections and the proper order.
2.Safety instructions and waiver of liability
2.1 Safety
①The solar charge controller may only be used in PV systems in accordance with this user manual and the specifications of other modules manufacturers. No energy source other than a solar generator may be connected to the solar charge controller.
②Batteries store a large amount of energy, never short circuit a battery under all circumstances. We strongly recommend connecting a fuse directly to the battery to protect any short circuit at the battery wiring.
③Batteries can produce flammable gases. Avoid making sparks, using fire or any naked flame. Make sure that the battery room is ventilated.
④Avoid touching or short circuiting wires or terminals.
Be aware that the voltages on special terminals or wires can be as much as twice the battery voltage. Use isolated tools, stand on dry ground, and keep your hands dry.
⑤Keep children away from batteries and the charge controller.
2.2 Liability Exclusion
The manufacturer shall not be liable for damages, especially on the battery, caused by use other than as intended or as mentioned in this manual or if the recommendations of the battery manufacturer are neglected. The manufacturer shall not be liable if there has been service or repair carried out by any unauthorized person, unusual use, wrong installation, or bad system design.
LATshine
③ ④ ① ② ⑤ ⑥
To avoid any voltage on the wires, first connect the wire to the controller, then to the battery, panel or load.
Make sure the wire length between battery and controller is as short as possible.
Recommended minimum wire size:
LATshine06: 1.5 mm²; LATshine10: 2.5mm².
Be aware that the positive terminal of Shine are connected together and therefore have the same electrical potential.
If any grounding is required, always do this on the positive wires.
Connecting capacitive load may trigger short circuit protection.
!
Remark: If the device is used in a vehicle which has the battery negative on the chassis, loads connected to the controller must not have an electric connection to the car body, otherwise the Low Voltage disconnect and electronic fuse functions of the controller are short circuited.
Page 1 of 3 pages
Solar Charge Controller LATshine06/10 User Manual
5.Starting up the controller
n c i u t a e , a l t e h h pl y to no rm l pe a o m o s u o i r 2 ys tem vo s e a e
t t e e t p t i 1 t h c i i m, s r ge s h 2 V o i mplies a 4 m t e a e v t t wi h a o 6 p t a a di t
0 3 n n
Err or s i
V e a t s t r T e
e i t y o i d t r r r l f u
o i i i
6.Display Functions
The controller is equipped with 5 LEDS.
In normal operation, the controller shows charge or discharge status, battery capacity and load status.
7.1 Safety features
Solar terminal Battery terminal Load terminal
Reverse polarity
Protected *1 Protected *1
Short circuit Protected Protected *3
Protected *2
Switches off immediately
Switches off with delay
Over current
Reverse
Current
Protected
Over voltage Max.55V *4
Under voltage
Over temp.
Max. 40V
Switches off switches off the load if the temperature reaches the set value.
*1 Controller can not protect itself in a 24V system when polarity of battery or solar is reversed.
*2 Controller can protect itself, but loads might be damaged.
*3 Battery must be protected by fuse, or battery will be permanently damaged.
*4 The solar panel voltage should not exceed this limit for a long time as voltage protection is done by a varistor.
!
Warning: The combination of different error conditions may cause damage to the controller.
Always remove the error before you continue connecting the controller.
7.2 Error description
6.1 Battery Capacity display:
Red
Yellow
Green
Red On, Energy of Battery <25%
Yellow On, Energy of Battery 25~75%
Green On, Energy of Battery >75%
!
The percentage corresponds to the available energy until low voltage disconnect in relation to a fully charged battery.
6.2 C harge & Error display (INFO):
Red Green
INFO Green On, is charging, else is discharge;
INFO Red On, is Error Status,
Error description.
Error Display Reason Remedy
Red
Loads are not supplied
Red LED is on
Red
Battery is low
Battery is empty after a short time
Red LED is flashing
Red
Red LED is on
Battery is not being charged during the day
Over current/ short circuit of loads
Battery has low capacity
Red Green
Green LED is off
Solar array faulty or wrong polarity
Over voltage protection
Does not recognize the system
voltage
Load will reconnect as soon as battery is recharged
Switch off all loads.
Remove short circuit.
Change battery
Remove faulty
connection/ reverse polarity
All LED
Lighted
Battery voltage too high
Red(INFO) and
Green(Bat.)
LED are lighted
(>15.5V/31V)
Battery wires or battery fuse damaged, battery has high resistance
Check if other sources overcharge the battery.
If not, controller
is damaged.
Check battery wires, fuse and battery.
The battery voltage is not within the normal operating rang at start-up
Charge or discharge the battery to make the voltage within the normal range
Page 2 of 3 pages
Solar Charge Controller LATshine06/10 User Manual
The controller uses state of charge to protect the battery form being deeply discharged, Shine series controller is disconnect at 11.0V/22.0V.
!
Note:
1. If the controller goes into low voltage protection, it will restore only when the battery being recharged and the voltage reaching the reconnect voltage.
2. Around oblique line value separately on behalf of 12V and 24V system's value.
9.Technical Data
Model
System voltage
Max solar current or load current
Fast voltage
Boost voltage
Equalization voltage
Float voltage
Load disconnect voltage
Load reconnect voltage
Battery type
Temperature compensation
Max solar voltage
Max battery voltage
Over voltage protection
Dimensions/Weight
W ire size
Own consumption
Ambient temperature
Degree of protection
LATshine06 LATshine10
12V/24V automatic recognition
6A 10A
14.0V/28.0V (25℃)
14.5V/29.0V (25℃)
14.8V/29.6V (25℃)(Liquid)
13.7V/27.4V (25℃)
11.0V/22.0V
12.5V/25.0V
Liquid, Gel
-4.17mV/K per cell (boost, equalization), -3.33mV/K per cell (float)
55V
40V
15.5V/ 31.0V
150x72x35mm / 130g
06 A : 1.5 mm²; 10 A : 2.5mm²
4mA
-40℃ ~ +60 ℃
IP22