Bar Code Printing Scale Cash Register Scale Cash Register Indicator User Manual 2017.4 V3.04A Preface Thank you for use the product. Before you start to use this product, please be sure you have read the content in the Preface and follow these guidelines. Notice Make sure the electric plugs and wires are all properly connected, and use the 3-cell electric wire only. If an extension-board is used, the outlet of the extension-board is also 3-cell. Make sure the earth wire is properly connected to the earth in order to prevent the leakage of electricity. Don’t touch the electric plug with wet hand, in case of electric shock. Don’t lean your body on the scale to avoid damaging the load cell. Don’t impact the scale or shock the scale with heavy goods, in case of damaging the load cell. When weighing, don’t exceed the maximum weighing range Don’t get the product rained or washed by water; If there is some water on the product by inadvertence, please wipe it clean with a dry cloth; If the scale doesn’t work normally, please send the scale to our distributor as soon as possible. We shall do our best to service you. Don’t put the scale in the places which are ultimately cold, hot or wet. These working conditions may make the product not work normally or damage the product. Don’t use organic chemistry solutions to wipe the surface and the panel of the product. Don’t try to take the scale apart and repair the scale by non-professonal staff. Don’t put your hands into the product through the place where the printer spins out. It may cause electric shock with 110V/220V electricity. Cut the connection between the scale and AC electricity when taking the scale apart under the guidance of professional staff from our company. Don’t try to disassembly the switch power inside of the scale. Because it takes a long time to discharge the high voltage capacitance, and it’s very dangerous to disassembly the switch power when the high voltage capacitance is not fully discharged. Strongly recommend users to use thermal paper sold by our company. The scale can have a longer life if working with thermal paper sold by our company because we have done a lot of experiments and optimizations on the our thermal paper. On contrary, the life span of the printer may get shortened if the printer works with the thermal paper, which is likely to deposit or leave carbon deposits. Thermal header is a precise instrument. Don’t touch it with fingers or sharp goods. Always use the accessary cleaning tools to keep the header clean. i Guide to Read Please go to page 8 Thermal Printer and learn the method to install paper and notices for users. Please read page 2 General Functions, Configuration and Using Index carefully first in order to know about the performance of the scale. Please read page 16 Fast Prog carefully first , and learn frequently used programme operations of the scale. For ordinary users, please first read page 21, the two chapters Transfer and Lock of PLU (page 21) and Manual Goods Sale (page 22) in the Sale Operations, and learn general sale operations of the scale. For ordinary users, read page 64 Account Operations, get to know how to print the report forms and delete the records. And read Operations of Sale Buffers in page 31 to learn how to look over the recent sale records. For advanced users, read the rest of Sale Operations,and learn auto mode and other functions. For professional users, such as managers in big supermarket, should continue reading the rest of the instruction. When error warning shows up, check Reference Table For Errors and Its Instructions in page 70 . Abbreviations and Glossary PLU: Price of LookUp. It’s a cell which contains the information of goods Weight PLU, Count PLU: By-weight PLU, By-Count PLU. Dept., Class: Dept. is short for department, is the largest category in sales statistics. Class is the second largest category in sales statistics. U.Price, T.Price: Unit Price and Total Price. Single T.Price, Sum T.Price: Single T. Price means the price of certain goods, while Sum T. Price means the price of total trade. Prog, F-Prog: Name of keys, Short for programme and Fast Programme. T-Sale: Temporarily Sale. Trade goods is not an exist PLU. Sell them by input a manual price. And the scale will think the goods as PLU 1 (Weight), or 2 (Count). Spec: Specification. It is made up of many number parameters, which determines the operation flow and working state. TMSet: Working parameters setting. DTSet: Working date setting. Amount: The quantity of the goods, weight or count. It means weight (kg, lb) for weight PLU and count (pcs) for count PLU 【Text】: Mark the Text as a key name. 〖Text〗: Mark the Text as a display indication name. ii Menu Preface ........................................................................................................................... i Notice .......................................................................................................................... i Guide to Read ............................................................................................................. ii Abbreviations and Glossary ....................................................................................... ii Menu ............................................................................................................................ iii Examples Menu ........................................................................................................ viii 1 Components of Barcode Print Scale ................................................................... 1 1.1 Check Accessories ................................................................................................ 1 1.2 Keyboard .............................................................................................................. 1 1.2.1 The Original Overlay of the Keyboard ..................................................................................................... 1 1.2.2 Instructions for Keys................................................................................................................................. 2 1.2.3 Instruments for Keys in Function Area ..................................................................................................... 2 1.2.4 Character Input Instructions...................................................................................................................... 4 1.3 Display Panel ........................................................................................................ 5 1.3.1 Sketch Map of Display Panel.................................................................................................................... 5 1.3.2 Indication Signs ........................................................................................................................................ 6 1.3.3 Expression of Characters .......................................................................................................................... 7 1.3.4 Dot Matrix Display ................................................................................................................................... 7 1.4 Specifications ....................................................................................................... 7 1.5 Thermal Printer (bar code label printing scale only) ........................................... 8 1.5.1 Install Gap Paper....................................................................................................................................... 8 1.5.2 Gap Paper Mounts Recycle ...................................................................................................................... 9 1.5.3 Install Plain Paper ..................................................................................................................................... 9 1.5.4 Operations Concerning Paper ................................................................................................................. 10 1.5.5 Abnormity of Gap Paper Print ................................................................................................................ 10 1.5.6 Specification for printing interface ..................................................................................................... 10 2 General Functions, Configuration and Using Index ....................................... 11 iii 2.1 General functions ............................................................................................... 11 2.2 Setting of Print Format ....................................................................................... 11 2.3 Barcode printing and scanning ........................................................................... 12 2.4 Measure Functions ............................................................................................. 12 2.5 Sale Functions .................................................................................................... 13 2.6 Salesman Function ............................................................................................. 14 2.7 Report Functions ................................................................................................ 14 2.8 Sales details ........................................................................................................ 14 2.9 Network function ................................................................................................ 14 2.10 Ethernet Thermal Printer .................................................................................. 15 2.11 Software use ..................................................................................................... 15 3 Fast Prog .............................................................................................................. 16 3.1 Fast-Prog of PLU................................................................................................ 16 3.2 Fast-Prog of Shortcut Key for PLU.................................................................... 18 3.3 Fast-Prog of Spec Parameters ............................................................................ 19 3.4 Fast-Prog of Unit price ....................................................................................... 20 4 Sale Operations ................................................................................................... 21 4.1 Transfer and Lock of PLU .................................................................................. 21 4.1.1 Transfer by Using PLU Number ............................................................................................................. 21 4.1.2 Tranfer by Using PLU Shortcut Keys ..................................................................................................... 21 4.1.3 Transfer Temporary Weight PLU ............................................................................................................ 22 4.1.4 Transfer Temporary Count PLU ............................................................................................................. 22 4.2 Manual Goods Sale ............................................................................................ 22 4.2.1 Sale and Print of Single Weight Goods ................................................................................................... 22 4.2.2 Sale and Print of Single Count Goods .................................................................................................... 23 iv 4.2.3 No Weigh Sale for Weight Goods ........................................................................................................... 23 4.2.4 Sale and Print for Different Kinds of Goods (No Cashing Mode) .......................................................... 24 4.2.5 Sale and Print for Different Kinds of Goods (Cashing Mode, Input Payment) ...................................... 24 4.2.6 Sale and Print for Different Kinds of Goods (Cashing Mode, Payment Equal to Price) ........................ 25 4.3 Discount Operations ........................................................................................... 25 4.3.1 U.Price Discount ..................................................................................................................................... 25 4.3.2 T.Price Discount...................................................................................................................................... 26 4.3.3 ±% price .................................................................................................................................................. 26 4.3.4 Auto Discount ......................................................................................................................................... 27 4.3.5 Unit Conversion of Temporary U.Price .................................................................................................. 28 4.4 Setting and Lock of Tare .................................................................................... 28 4.4.1 Weight Tare ............................................................................................................................................. 28 4.4.2 Number Tare ........................................................................................................................................... 28 4.4.3 Lock and Unlock of Tare ........................................................................................................................ 29 4.5 Special sale mode ............................................................................................... 29 4.5.1 Enter and Exit of Special sale Mode ....................................................................................................... 29 4.5.2 Sale under batch print mode ................................................................................................................... 30 4.5.3 Sale under prepack mode (only for weight PLU) ................................................................................... 30 4.5.4 Sale under Lock PLU mode .................................................................................................................... 31 4.5.5 Auto print mode (only for weight PLU) ................................................................................................. 31 4.6 Operations of Sale Buffers ................................................................................. 31 4.6.1 Switch of Sale Buffers ............................................................................................................................ 31 4.6.2 Cancel Sale Data in Sale Buffers ............................................................................................................ 32 4.7 Salesman and Waiter .......................................................................................... 33 4.7.1 Personnel Information ............................................................................................................................ 33 4.7.2 Salesman Function .................................................................................................................................. 33 4.7.3 Waiter Function....................................................................................................................................... 33 4.8 Inquiry of Sale Records and Markers of Returns of Goods ............................... 33 4.9 Manual Weight ................................................................................................... 34 4.9.1 Manual Sale of Manual Weight Entry..................................................................................................... 34 4.10 Bar code printing and scanning ........................................................................ 34 4.10.1 Exterior bar code................................................................................................................................... 34 v 4.10.2 Interior bar code .................................................................................................................................... 35 5 Programme Operations...................................................................................... 36 5.1 Please Read this Part First .................................................................................. 36 5.2 Basic Operations in Programme Interface ......................................................... 36 5.2.1 Tree-shaped Design of Edit Steps ........................................................................................................... 36 5.2.2 Frequently-used Keys in Prog Interfaces ................................................................................................ 37 5.2.3 List of Programme Interface ................................................................................................................... 38 5.3 The Edit of All Parts in TMSet ........................................................................... 44 5.3.1 Time Programme .................................................................................................................................... 44 5.3.2 Programme of Spec Parameters .............................................................................................................. 44 5.3.3 Programme of Text Parameters ............................................................................................................... 45 5.3.4 Programme of PLU Shortcut Keys ......................................................................................................... 45 5.3.5 Programme of Fuction Shortcut Keys .................................................................................................... 46 5.4 The Edit of All Parts in DTSet ........................................................................... 46 5.4.1 Department Programme .......................................................................................................................... 46 5.4.2 Class Programme .................................................................................................................................... 47 5.4.3 PLU Programme ..................................................................................................................................... 47 5.4.4 Unit Programme...................................................................................................................................... 49 5.4.5 Barcode Programme ............................................................................................................................... 50 5.4.6 Print Formats Programme ....................................................................................................................... 53 5.4.7 Salesman Programme ............................................................................................................................. 56 5.5 Assistant Data Programme ................................................................................. 57 5.5.1 Steps Select of PLU Programme ............................................................................................................ 57 5.5.2 Steps Select of PLU Fast Programme ..................................................................................................... 57 5.5.3 Delete Sale Data ..................................................................................................................................... 58 5.6 Communication and Data Update ...................................................................... 59 5.6.1 Operations of files in USB flash Disk. ................................................................................................... 59 5.6.2 Ethernet Monitor Interface...................................................................................................................... 60 5.6.3 RS232 Communications ......................................................................................................................... 61 5.7 Hardware Assistant ............................................................................................. 61 5.7.1 Validate Code .......................................................................................................................................... 61 5.7.2 Password ................................................................................................................................................. 61 vi 5.7.3 Recover Factory Default Setting............................................................................................................. 62 6 Account Operations ............................................................................................ 64 6.1 List of Account Interfaces .................................................................................. 64 6.2 Operations of Printing Report ............................................................................ 64 6.2.1 Print Total Report.................................................................................................................................... 64 6.2.2 Print Department Report ......................................................................................................................... 65 6.2.3 Print Class Report ................................................................................................................................... 65 6.2.4 Print PLU Report .................................................................................................................................... 65 6.3 Clear Report Information ................................................................................... 66 6.3.1 Clear Report Information Manually ....................................................................................................... 66 6.3.2 Clear All Reports and Records Information............................................................................................ 66 6.3.3 Clear stock information........................................................................................................................ 66 6.3.4 Reposition SID information ................................................................................................................. 67 6.4 Stock Management ............................................................................................. 67 6.4.1 Stock Management ................................................................................................................................. 67 6.4.2 Stcok Print .............................................................................................................................................. 67 6.4.3 Stock Audit ............................................................................................................................................ 68 6.5 List Print ............................................................................................................. 68 6.5.1 Sale Log ................................................................................................................................................. 68 6.5.2 List Print ................................................................................................................................................ 68 7 Appendix.............................................................................................................. 70 7.1 Reference Table For Errors and Its Instructions................................................. 70 7.2 Definitions of Spec data parameters................................................................... 73 7.3 Definitions of String data paremeters................................................................. 88 7.4 Definitions of Shortcut Function Key ................................................................ 88 vii Examples Menu Example 3-1 Fast-Prog of PLU ............................................................................................................................... 16 Example 3-2 Fast-Prog of Shortcut Key for PLU. Amend a shortcut key. .............................................................. 18 Example 3-3 Fast-Prog of Shortcut Key for PLU. Amend two or more shortcut keys............................................ 18 Example 3-4 Fast-Prog of Spec Parameters ............................................................................................................ 19 Example 3-5 Fast-Prog of unit price (Spec083=1) .................................................................................................. 20 Example 3-6 Fast-Prog of unit price (Spec083=2) .................................................................................................. 20 Example 4-1 Use PLU Number to Transfer Weight PLU ........................................................................................ 21 Example 4-2 Use PLU Number to Transfer Count PLU ......................................................................................... 21 Example 4-3 Use PLU Shortcut Keys to Transfer Weight PLU .............................................................................. 21 Example 4-4 Use PLU Shortcut Keys to Transfer Count PLU ................................................................................ 21 Example 4-5 Transfer Temporary Weight PLU ....................................................................................................... 22 Example 4-6 Transfer Temporary Weight PLU with a Unit Conversion of the U.Price. ......................................... 22 Example 4-7 Temporary PLU number is decided by Spec094(default 9999998) ................................................... 22 Example 4-8 Sale for Single Weight goods ............................................................................................................. 22 Example 4-9 Sale and Print for Single Count goods ............................................................................................... 23 Example 4-10 No Weigh Sale for Weight PLU ....................................................................................................... 23 Example 4-11 Sale and Print for Different Kinds of Goods (No Cashing Mode) ................................................... 24 Example 4-12 Sale and Print for Different Kinds of Goods (Cashing Mode, Input Payment) ................................ 24 Example 4-13 Sale and Print for Different Kinds of Goods (Cashing Mode, Payment Equal to Price).................. 25 Example 4-14 Execute Discount in Subtraction ...................................................................................................... 25 Example 4-15 Execute Discount at a Fixed Number ............................................................................................... 25 Example 4-16 Input data to execute ±% price ......................................................................................................... 26 Example 4-17 Enterinterface and execute ±%price ................................................................................................. 26 Example 4-18 Directly execute default ±%price(Spec114) ..................................................................................... 27 Example 4-19 Auto Discount................................................................................................................................... 27 Example 4-20 Unit Conversion of Temporary U.Price............................................................................................ 28 Example 4-21 Weight Tare ...................................................................................................................................... 28 Example 4-22 Number Tare ..................................................................................................................................... 28 Example 4-23 Tare Lock and Unlock ...................................................................................................................... 29 viii Example 4-24 Single key select of sale mode ......................................................................................................... 29 Example 4-25 Interface select sale mode ................................................................................................................ 29 Example 4-26 Batch Print mode .............................................................................................................................. 30 Example 4-27 Prepack mode(only for weight PLU) ............................................................................................... 30 Example 4-28 Switch of Sale Buffers...................................................................................................................... 31 Example 4-29 Clear All Data in Current Sale Buffers ............................................................................................. 32 Example 4-30 Clear One Goods in Current Sale Buffer.......................................................................................... 32 Example 4-31 Inquiry of Sale Records and Markers of Returns of Goods ............................................................. 33 Example 4-32 Manual Sale of Manual Weight Entry .............................................................................................. 34 Example 5-1 Time Programme ................................................................................................................................ 44 Example 5-2 Programme of Spec parameters.......................................................................................................... 44 Example 5-3 Programme of Text Parameters .......................................................................................................... 45 Example 5-4 Programme of PLU Shortcut Keys..................................................................................................... 45 Example 5-5 Programme of Fuction Shortcut Keys ................................................................................................ 46 Example 5-6 Department Programme ..................................................................................................................... 46 Example 5-7 Class Programme ............................................................................................................................... 47 Example 5-8 PLU Programme................................................................................................................................. 48 Example 5-9 Unit Programme ................................................................................................................................. 50 Example 5-10 Barcode Programme ......................................................................................................................... 50 Example 5-11 Salesman Programme ....................................................................................................................... 56 Example 5-12 Steps Select of PLU Programme ...................................................................................................... 57 Example 5-13 Steps Select of PLU Fast Programme .............................................................................................. 57 Example 5-14 Delete PLU20~30 ........................................................................................................................... 58 Example 5-13 Load Files in USB Flash Disk .......................................................................................................... 59 Example 5-14 Save working data to Files in USB Flash Disk ................................................................................ 59 Example 5-15 Save sale list to Files in USB Flash Disk ......................................................................................... 60 Example 5-16 Enter Ethernet Monitor Interface ..................................................................................................... 60 Example 5-17 Process of Amending Passwords ...................................................................................................... 62 Example 5-18 Process of Amending Passwords ...................................................................................................... 62 Example 6-1 Print Daily Reports of Today and Yesterday ...................................................................................... 65 Example 6-2 Print PLU Daily Reports with the Numbers from 10 to 20 ................................ 错误!未定义书签。 ix Example 6-3 Clear Information in Manual Report .................................................................................................. 66 Example 6-4 Clear All Reports and Records Information ....................................................................................... 66 Example 6-5 Clear stock information ...................................................................................................................... 66 Example 6-6 Clear manual report ............................................................................................................................ 67 Example 6-7 Print stock Reports with the Numbers from 10 to 20 ......................................................................... 67 Example 6-8 Amend PLU10 stock to 100 ............................................................................................................... 68 Example 6-9 Intraday List Print .............................................................................................................................. 68 Example 6-10 Appointed Time Period List Print..................................................................................................... 69 x 1 Components of Barcode Print Scale 1.1 Check Accessories One scale or indicator; One tray(scale only); One display pole (pole type only); One pack of screws used to fix the pole (pole scale only); One copy User Manual (this book); One CD for PC software TM-xA Management Software One overlay for shortcut PLU; One power plug; 1.2 Keyboard 1.2.1 The Original Overlay of the Keyboard Picture 1-1 Sketch Map of Keyboard Function for barcode label printing scale (Pole) 7 8 9 4 5 6 1 2 3 X 0 00 Picture 1-2 Sketch Map of Keyboard Function for barcode label printing scale (Bench) Picture 1-3 Sketch Map of Keyboard Function for cash register scale 1 Picture 1-4 Sketch Map of Keyboard Function for cash register indicator The graph above shows the original definitions. Some buttons on the left top area are marked with numbers, which are serial number for the shortcut keys. In this text, 【SCxx】 is used to represent shortcut keys. For example, 【SC1】 represents the first key on the left top marked with number 1. 【SCxx】on the left side are PLU preset shortcut keys and can be set to represent one certain key if user requests. When editing the text, 【SCxx】 are function keys and character keys for the input of letters. Please refer to chapter 1.2.4. 【SCxx】on the right side are preset shortcut keys for additional functions . The presetting is shown in the graph. And it’s not available for user to change the setting of function keys now. 1.2.2 Instructions for Keys When you press right keys, the scale would beep shortly to show the operation is right. When you press wrong keys, the scale will beep in 1 long sound and 2 short sounds. The composite beeps mean the failure in operation process or errors in pressing keys. If operaton process fails, there will be Ex.xx displayed on the screen (e.g., E1.01 means programme data is invalid.). It may take 4 seconds to press one key in the operation which needs to Long Press the key without releasing it. During the period you will hear 2 beeps. The first beep sounds as soon as you press the key while the other one sounds 4 seconds after pressing the key. In some【F-Prog】+【Other key】 operations, users should first press 【F-Prog】 without releasing and press the 【Other key】 in order to complete the operation. In the following instruction: 【Key1】 【Key2】 means the operation that press 【Key 1】first and release it, then perss【Key 2】and release it. 【Key1】+【Key2】means the operation that press 【Key1】 and 【Key2】 at the same time. When users do it , press 【Key1】 first, and press 【Key2】 without releasing 【Key1】 . 1.2.3 Instruments for Keys in Function Area Picture 1-1 shows the default setting of keys in the function area. According to customer’s requests, default setting may be different. And the specific setting will be on the overlay: 【Sale】: Enter sale mode and execute the operation of goods sale. 【Prog】: Enter programme mode and programme on parameters, PLU, print formats, time and so on. 【Account】: Enter Account mode to inquire about deals data or print reports and so on. 【Time】: Display current time and return to the previous interface when you press it again. 2 【Mode】: Switch in Sale, Prog, Account Mode. 【Tare】: Set current weight as tare or appoint certain data as tare (When there is a number in input window, number tare is the priority.). Pressing 【Tare】 for a long time without releasing, system would enter 【Tare Lock】. And do it again to exit this state. 【Zero】: Clear current weight and reset zero within allowed range. If not within allowed range, set zero would fail. 【Shift】: Shife key used for extending PLU shortcut key, and switching case sensitivity in text input interface. When current input number is decimal (tare, weight, U.Price, T.Price) , long press 【Shift】or press 【F-Prog】+【Shift】 would change the position of decimal point. 【Auto Mode】 【Pre-Pack Mode】, 【Batch-Pint mode】, 【Auto print】 【Lock PLU】: Switch ordinary mode with pther sale mode. Users can long-press this key to enter sale mode select if current sale buffer is empty. 【Manual Weight】:Key for manual entry of weight. “ManWT” will add before weight data while printing. Open this functions in Spec if user needs it. 【Paper Type】: Long Press it switch paper between gap thermal paper and plain thermal paper. 【Re-print】: Repeat last print in current buffer (Repeated print data would not be stored in deal records as sale record.). This function can be forbidden in Spec. 【Feed】: Roll the gap thermal paper and plain thermal paper. Unprinted buffer data will be cleared in the process of feed. 【-%】【±%】: Discount in percentage, PDis P(1 Input ) . Please notice that input is decimal and pay 100 extra attention to the position of decimal point. Discount is 5% off while input is 500, if there are two zeroes after decimal point. And input should be 5000, If there are three zeroes. You can refer to Spec113, Spec114 for detailed explaination. 【-Num】: Discount in subtraction. PDis P Input . Input is also decimal. 【[email protected]】【@Price】:: Discount to a fixed price. PDis Input . Input is also decimal. You can also use this key to save the discounted price to PLU directly, please refer to Spec083 【T-Sale】: Set input number as Unit Price and set a temporary PLU. You can amend the temporary weight PLU’s unit in Spec, for example, if the temporary weight PLU’s unit is 500g, but the scaleunit is kg, then system will antomatically conversion (multiply 2) 【Drawer】: Open drawer besides normal operations. 【CCard】or【Credit payment】: Obligate function 【F-Prog】: Change some setting or values of PLU fastly in sale mode. It is always used for combination of keys, which is similar as ‘Alt’ ‘Ctrl’ in PC keyboard. Please refer to process instructions to understand the use of combination keys. 【×】: Input count amount in count sale. Or do temporary count goods sale according to input U.Price. 【Amend】: Amend deal data in sale interface and store amended data in programme interface. 3 【←】【↑】 【↓】【→】: Switch among neighbouring steps and numbers in programme and account interfaces. 【V1】~【V4】: Activate corresponding sale buffers. 【0】~【9】,【00】: Input corresponding numbers. 【Back】: Delete the last digit input number. 【PLU】: Transfer PLU datas using input numbers as serial numbers. 【Cash/Print】: Check out in cash; calculate changes and print labels or receipts according to setting. 【Cancel】: Clear data, cancel operations or go back to previous step. 【Accu/Confirm】: Save accumulative deal data into activated sale buffer and other confirmation operations. 1.2.4 Character Input Instructions The key of function section remains the same when system enters letters input interface, while 【SC1】~ 【SC63】 are used to input letters. In input process, definitions of keyboard are shown below: 【Amend】: Confirm text input. Save and exit. 【Cancel】: Cancel edited data and quit without saving. 【Confirm】: Confirm the input in special IME (not used in pure English version). 【End】: Input end character, and all characters after appointed position are deleted. 【Delete】: Delete the character at the position where cursor is. 【Insert】: Switch cover mode with insert mode. Cover mode is activated when cursor is constant on while insert mode is activated when cursor is glittering. 【IME】: Input method editor. Switch the input languages: En-1 (in small letters), En-2 (in big letters), Chs (chinese code), Code (machine code). 【Shift】: Switch En-1, En-2 in temporary state. 【←】【→】: Move current editing position backwards or forwards. 【0】~【9】 and【SC1】~【SC59】: Input characters or codes. In the process of input text, meanings of four windows are shown below: The first window: Display current input mode: one of En-1, En-2, Chs and Code. The second window: Display the position of current editing letters in the text. The third window: Display current editing position and content of neighing letters. In En-1 or En-2 ASCII mode is displayed while in Chs or Code Hex mode is displayed. Cover mode is activated when cursor which shows the position is constant on, while insert mode is activated when cursor is glitter. The fourth window: Display current input content. In En-1 or En-2 the window displays nothing, and in Code input machine code is displayed. Switch 4 kinds of input languages by pressing switch keys. Input mode of each kind of input language is shown below: En-1 small letter: Input numbers or ASCII characters. For the keys with ‘/’, input character is the one on the left of ‘/’. Pressing【Shift】, next input character and only this one is under the rule of En-2 . En-2 capital letter: Input numbers or ASCII characters. For the keys with ‘/’, input character is the one on 4 the right of ‘/’. Pressing【Shift】, next input character and only this one is under the rule of En-1 . UTF8 (U version IME, for UTF8 font scale use only): UTF-8 input method, input Unicode to get the characters, input different kinds of non-English language characters, please check code from UTF8 Test Editor Manual, after input Unicode, press【Confirm】to finish the input PY Chinese pinyin mode (E version IME, font scale use only): Input pinyin, and select chinese character by【←】【→】, Press【Confirm】 to input a Chinese character. In pinyin mode, Press 【Space】to select SBC case symbol, Press 【Space】 twice to select English symbol. Chs Chinese ISN mode (E version IME, font scale use only): Input ISN code to select a Chinese character or SBC case symbol. Code: Input machine code mode. Users can input ASCII, symbols in special IMEs. The system could automatically distinguish the input content as ASCII, symbols in special IMEs. Machine codes of each field can be found in following table. Table 1-1 ASCII Code Table 0 0 1 2 3 4 5 6 7 8 9 1 2 3 4 5 6 7 8 9 A B C D E F * : J Z J Z + ; K [ k { , < L \ l | . = > M N ] ^ m n } ~ / ? O _ o Non-print character ! 0 1 @ A P Q ` a p q “ 2 B R b r # 3 C S c s $ 4 D T d t % & 5 6 E F U V E f U v ‘ 7 G W g w ( 8 H X h x ) 9 I Y i y Not used 1.3 Display Panel 1.3.1 Sketch Map of Display Panel Picture 1-5 Display Overlay 5 Picture 1-6 Display Overlay with Dot-matrix Display 1.3.2 Indication Signs 〖Zero〗: It’s on when weight is zero and stable. 〖Stable〗: It’s on when weight is stable. 〖Lock Tare〗: It’s on when tare is locked. Long press 【Tare】 would lock tare. Under this condition, tare would not be cleared after the sale. Long press 【Tare】 again would exit lock tare. 〖Lock PLU〗: It’s on when PLU is locked. Long press 【PLU】 would lock PLU. Under this condition, former PLU sale state would remain the same after the sale. And it will last until new PLU is transferred. Long press 【PLU】 again would exit lock PLU. 〖Auto mode〗: It’s on in auto mode. When in auto mode, lock PLU will active. In this mode, pre-pack or batch print is executed based on Spec078 and Spec079. 〖Pre-pack〗same as 〖Auto mode〗 〖Auto Print〗the light will on when in auto printing 〖Manual Weight〗:It’s on when manual weight is displayed. 〖Gap paper〗: It’s on when paper type is gap paper. If it’s off when paper type is plain paper. 〖NET〗: It’s on when tare is set and net weight is displayed. Press 〖Fast Prog〗 〖Tare〗will display gross weight 〖Shift〗: Press 【Shift】 and it is on. 〖Sale〗: It’s on in sale mode. 〖Prog〗: It’s on in programme mode. 〖Account〗: It’s on in account mode. 〖Change〗: It’s on when the data in third window is displayed as cash change. 〖U.Price〗: It’s on when the data in third window is displayed as goods U.Price. 〖V1〗~〖V4〗: It’s on when there are buffers in V1~V4 records. And it’s glittering in edit mode. 〖Discount〗: To display single means that current goods has been discounted in U.Price; To display total means that current accumulative total has been discounted in T.Price 〖Single〗: It’s on when total price of current goods is displayed in fourth window. 〖Sum〗: It’s on when the sum total price of current sale buffers (V1~V4) is displayed in fourth window. 6 1.3.3 Expression of Characters Picture 1-7 Number Characters 0~9 Picture 1-8 Characters A~M Picture 1-9 Characters N~Z Picture 1-10 Dash、underline, aboveline, three lineations of special symbols Dash of special symbols: the same as ‘-’ in ASCII. Underline of special symbols: Used to represent the characters which cannot be displayed in ASCII(the symbols except 0~9, A~Z and ‘-’) Aboveline of special symbols: Used to represent extended characters. In Chinese edition, two aboveline represent a Chinese character. Three lineations of special symbols: In calibrating processes, it’s used as a prompt to decide to enter calibrating interface or standard interface. 1.3.4 Dot Matrix Display 5-windows scales have an additional 160×32 dot matrix LCD display. It displays time or ad-message or accumulation record in idle mode; and displays PLU’s name in PLU mode. 1.4 Specifications Power supply: AC200V~240V, 47~53Hz Operation temperature: 0℃~40℃ Conservation temperature: -20℃~70℃ Operation humidity: 15%~85%RH 7 Capacity Resolution Division Accuracy 6kg 3000 2g III 15kg 3000 5g III 30kg 3000 10g III 1.5 Thermal Printer (bar code label printing scale only) 1.5.1 Install Gap Paper Install process is as below: Left is drawer structure (08’s). Right is cover structure (12’s) 1.Open Upper door 1.Open side door Picture 1-11 Open door of scale printer Hook Raise Fall 2.Raise the print head 2.Move hook in direction of arrow Picture 1-12 Open press mouth 4.Rotate LIMIT 90 ,for paper pass though 3.Rotate up LIMIT 4.Install paper roll 3.Install paper roll Picture 1-13 Install paper roll 8 5. Paper get through 5.Paper get through 7.Roll paper 7. Roll Paper 6.Remove U Spring 6. Remove U Spring Picture 1-14 Paper through 10.Adjust LIMIT height 9.Press down header 10.Adjust LIMIT height 8.Sandwich paper by U spring 9.Close header 8. Sandwich paper by U spring Picture 1-15 Finish paper install 11.Cover door 12.Press【Feed】 12.Press【Feed】 11.Close door Picture 1-16 Close door of scale printer 1.5.2 Gap Paper Mounts Recycle Pull out spring Picture 1-17 Gap paper mounts recycle 1.5.3 Install Plain Paper Different from the way in installing gap paper shown in 1.5.1, U-shaped paper retaining spring is not needed anymore. All you need to do is to put the paper into the paper sensor and let the tear part be outside. 9 1.5.4 Operations Concerning Paper 【Paper Type】: Make sure the type of paper set is the same as the type used. When 〖Gap Paper〗is light in the display, you should set to use gap paper. Otherwise you should set to use plain paper. If the type of paper you set to use is different from the type currently used, please long press 【Paper Type】to change the set. 【Feed】: After installing the paper, press【Feed】. You can also press 【Feed】 to clear abnormities of the printer and make paper roll for a certain length. 1.5.5 Abnormity of Gap Paper Print Users of plain paper don’t do any adjustment for this. Abnormity of printer parameters may happen when gap paper prints are unnormal, paper goes out continuously, or printer can’ work after one paper is printed, printing parameter maybe have abnormity Users need to check if paper type is right first. Then users could follow these operations below to eliminate malfunctions: Install gap paper, and make the edge of gap paper not exceed print head. (Not block the paper-out sensor) Picture 1-18 Paper-Out sensor Switch off the scale. Press the 【Feed】key then swith on the scale, hold this key until finished self checking and go into work inteface Printer would roll out the paper at the length of 50mm. automatically After the paper is rolled out, malfunctions have been eliminated if without any warning. If alarm E7.10 means calibration abnormity, pls try again after confirming the sticker perper has been used. Then, press 【Feed】to print the test page Go to normal operation processes. 1.5.6 Specification for printing interface Window Sample Tare Weight/Count E7.1x If normal printing, this When mass window is blank, if printing, this have error, will display window will Specification erro message, the display the mean for message pls number rest refer to Addenda 7.1 unprinted. CHG/Unit Price P1-02 Display present printing doc and number. P1-01 means the 2nd page of Doc 1. If total print 1 page, this window will blank. U.Weight/T.Weight Print When printing display: Print Not Printing wil display blank. 10 2 General Functions, Configuration and Using Index 2.1 General functions The printer can store 5990 PLUs. (Can extend to 10000 PLUs) Users can use gap thermal paper (TM-xA Series) and plain thermal paper. The printer provides many kinds of price input and discount. The print provides reports print for different time periods and classifications Precision of measurement: business mode 1/6000 (1/7500 for 15kg), industrial mode 1/30000. Support network, use RS232 and U disc as tool of data transer, all data can set on the PC, then use these interface to upload and download. Save sales details, can upload to PC through above interface 5-windows scales have an additional 160×32 dot matrix LCD display. 2.2 Setting of Print Format Bar Code Printing Scale: Press【Paper Type】for 4 seconds to switch between gap paper and plain paper. This key would amend Spec021. Bar Code Printing Scale: There are 9 kinds of default print formats. Please reference to Factory Default Print Formats in page 53.table 5-5 Bar Code Printing Scale: 58mm*40mm and 40mm*30mm gap paper, 58mm and 40mm width plain paper are available in default print formats. When using different type of paper, please adjust the corresponding Spec shown in the table below. Paper type Spec Print type Instructions 000 005 027 58mm*40mm Label print 1 4 50 Default gap paper Receipt print 7 7 50 Not recommend 40mm*30mm Label print 2 5 36 gap paper Receipt print 8 8 36 58mm width Label print 1 4 50 plain paper Receipt print 7 7 50 40mm width Label print 2 5 36 plain paper Receipt print 8 8 36 Not recommend Cash Register Scale: Cash register scale preset support 55mm width plain paper, default using recept printing format Print formats include label print and receipt print. If user needs custom print format, please use PC software to change or contact with appointed after-service cencer. Don’t print bills while saling: amend Spec003 and Spec008 to 0. If some specific deals need to print bills, please press 【Reprint】. To print a few copies of one bill, put the amount into Spec003 and Spec008. 11 To print two different kinds of bills: set the type of bill 1 in Spec000~Spec009, and bill 2 in Spec010~Spec019. Strongly suggest users contact with appointed after-service cencer Set grey level of gap thermal paper in Spec022. Set grey level of plain thermal paper in Spec023. Set plain thermal paper in Spec 025, the position for cut-off paper suggest Spec025 not less than 30 You can set different kinds of print formats and barcode types for each PLU. You can check the details in PLU parameters for print formats and barcode types. Set the value of these parameters to 0 if you choose the system type. The procedures to confirm print format: take bill 1 as an example. If two or more goods are sold, print sum bill and use Spec005 as print format. If only one good is sold, print the item bill. If sale PLU has been set for a specific print format (not 0), system would use the print format. If no specific print format has been set to sale PLU (The setting number is 0.), the print format would be Spec000. 2.3 Barcode printing and scanning Can print various kinds of bar code, 9 kinds of default barcode settings, details in page 52 Table 5-4 Factory Default Barcode. Can scan inner code and external code, details in page 34, the specification of Bar code printing and scanning Barcodes can be divided by use into item barcodes and total barcodes, which are printed in item labels and total labels respectively. Factory default barcodes support 5-digits total price and 6-digits total price. Please select the barcode compatible with the POS 001 006 Spec 002 007 1 7 xx xx00000 6 4 8 xx xx0000 Flag Code Using PLU Item-Code 5 2 7 xx xxyyyyy 6 5 8 xx xxyyyy No Flag Code Using PLU Item-Code 5 3 7 yyyyyyy 6 6 8 yyyyyy Goods Code Flag Code Using PLU No. Digits of Price 5 Default Suggestion x…is the flag code which is reserved for scale in POS system. User could define 0 as a MISC code for PLU Number never equal to 0. x…is the flag code which is reserved for scale in POS system. y… is a MISC code for total label. PLU’s Item-Code is code in POS system. No flag code defined. y… is a MISC code for total label. PLU’s Item-Code is code in POS system. If users need special bar code format, please use PC suite or contact with after-service center. 2.4 Measure Functions The scale offers 6 default measure units as kg, gram, ton, lb, 500g, 100g. Based on the difference national regulations, some of the measure unit may Not Open. The combinations 12 and recommended Spec settings are all shown below: Weight display kg g g lb U.Price display /kg /g /100g /lb 212 3 4 4 6 Spec 211 200 0or 3 3 0or 4 0 8 0 6 3 201 3 0 0 3 208 3 0 0 3 Instructions Default Weight precision: The precisions are divied into four levels. Level 0 owns original 1/3000. Level 0 and level 1 are available for commercial users while level 2 and level 3 are only available for industrial users (“*” would be attached in the print of weight). Please refer to Spec213. We guarantee the stability and reliability for precision level 0 (1/3000) when the scale leaves factory. And the higher precisions are here to satisfy the need of high definition print for some users, so factory would not guarantee the stability and reliability for higher precision levels for every scale. Please choose the precision prudentially. The request Zero-Return for scale print: it’s requested in commercial sales that total weight (sum of net weight and tare weight) of the scale have to return to zero when the scale is going to print the weights of two goods. But for industrial users, this rule could be ignored. Set the value of Spec069 to 2. (“Ind” would be attached in the print of weight). 2.5 Sale Functions Users could operate accumulative sales with 4 customers at the same time. Please refer to the Example 4-28 in page 31 for operations. Rounding methods could be divided into rounding method for single and rounding method for total. The settings of rounding methods are shown in Spec100 and Spec101. Suggest that set the value of Spec100 to 1 if users don’t want the unit “cent” to be displayed in sales. Suggest that set the values of Spec100 to 0 and Spec101 to 1 if users want the unit “cent” to be in sale while unit “cent” is not displayed in grand total and print. The units’ conversion for PLU default U.Price: set PLU U.Price to 10.00, the unit is 500gram and unit displayed is kg. When transfer PLU10, unti price is displayed as 20.00. Units’ conversion for temporary unit price: the scale offers the function of units’ conversion for temporary unit goods and price from 500gram to kg. When U.Price’ display unit is /kg, set the value of Spec210 to 7 and the value of Spec073 to 1 to activate this function. Please refer to the Example 4-6 in page 22, Example 4-20 in page 28. No Weigh Sale for Weight PLU: set the value of Spec071 to 1. When the weight returns to zero in weigh sale, input the price and sell the goods at the price you input. Please refer to Example 4-10 in page 23. Users can discount on U.Price and T.Price conveniently. The discount methods include discount at a fixed number, discount in subtraction and discount in percentage. Please refer to Discount Operations in page 25. Users can make a manual weight sale: set the value of Spec077 to non-zero (1, 2 or 3 are ok). Manual 13 weight entry can be executed if weight keeps at zero. Refer to the content of <manual weight> on page 1 Total price Masked before printing: set the value of Spec130 to 1. It will not display current transaction amount till press 【Print】key Auto record after zero-return set the value of Spec 131 to 1 or 2 (1:unforced 2:forced)., scale still record the transaction in un print condition, convenient to check and audit Auto printing after zero-return: set the value of Spec131 to 3. In weight sale, it will come back to zero in PLU, it will print according to last stable weight. Forced auto printing after zero-return: set the value of Spec131 to 4. In weight sale, when record and valid sale data it will auto printing after zero-return enable while user can not cancel the auto print by quit the PLU. 2.6 Salesman Function User could enable salesman login functions. Please refer to Salesman in page 33 and Spec135. 2.7 Report Functions Users could print the total reports with time periods of last 32 stat. day, stat. month, stat. quarter or manual time period. Users can print the reports for all departments, all classes and part of PLU (below 1000), with a time period of present stat. day, stat. month, stat. quarter or manual time period. Please refer to Account Operations in page 64 for the details. 2.8 Sales details The scale not only with report print function,but also store the sales record in details, this record can transfer to PC via internet, RS232 or U-disk. Because the storage room limit, if operator don’t transfer the details often, the scale will delete the old record automatically to save the new records. The storage for the sales details is 6000 records (can enlarge into 10000 and more). Each cargo takes one record. 2.9 Network function In local area network with a PC or Router enabled DHCP service, scales can connect to network directly without any IP setting. If you want to nominate the IP for certain scale, to set Spec150~153 is for 4 segment of IP(Default is 192.168.0.0. When last segment is 0, that means scale connect with Network with way of DHCP. Also means that default way is DHCP), Spec158~161 is for 4 segment of gateway of Network. (Default is 192.168.0.1). If the Network for the scale and PC is not in the same one, you can make that with directional connect way. Directional connect include: From PC to scale (should nominate the IP of certain scale on the PC software), and from scale to PC(should set Spec043 as 2-----client end mode, and set IP of PC at 14 Spec154~157) Spec166~Spec169 is for the scale’s Network Port, change these items may lead to abnormality with Network. Normally please don’t modify these 4 items. 2.10 Ethernet Thermal Printer Device can connect with Ethernet thermal printer produced by our company, which uses as Remote Printer. User can connect Printer and device one-to-one with Crossover Cable. Or connect printers and devices to Ethernet router (with DHCP function) for one-to-many, many-to-one, or many-to-many network. User can appoint special print format for Ethernet printer, which may different to printer on the device. 2.11 Software use In the CD, there is software manual, you can kindly install and use according to the manual. The user name of the PC software is user, the original password is blank. The administer name of the PC software is admin, the original password is 200806. You can click Help----Manual after run the software, to check the software manual. 15 3 Fast Prog Fast prog is the programme operation that draws out some frequently-used programme functions and enables users enter certain frequently-used programme interfaces without selecting in programme interface. Please make sure system is in the interface of idle sale before transferring fast prog. If system is not in sale operation, pressing 【Sale】 could enter the interface of idle sale. If system is in sale operation, pressing 【Cancel】 for several times could quit sale process and enter the interface of 『Sale Idle』. The sign of the interface of idle sale is that two lights 〖Sale〗 and 〖Sum〗 are on. On contrary, if two light of 〖Sale〗 and 〖Single〗 are on , system is in sale PLU interface. 3.1 Fast-Prog of PLU Press 【F-Prog】+【PLU】 to enter PLU Fast Prog. The process of programme is similar with PLU programme in standard programme interface. But users can finish PLU Fast Prog in sale interface. Example 3-1 Fast-Prog of PLU Edit PLU10 as a weight PLU with the name Pork-2, U.Price $30.00/kg, cost $24.00/kg and tare 0.005g. Operations Keys 『Sale Idle』 Tare 0.000 【F-Prog】+ F23 PLU Fast Prog 【PLU】 PLU Number 【1】【0】 F23 Go to Next F23 【】 Display Weight/ Change/ Count U.Price 0.000 0.00 PLU.00 Not Set Step No. Step Info PLU.00 Not Set PLU.01 ICode Input Item-Code 90001 F23 PLU.01 ICode Go to Next 【】 F23 PLU.03 Unit Set as weight PLU 【1】 F23 PLU.03 Unit Go to Next 【】 F23 PLU.04 Price Remarks Single/ Total 0.00 〖Sale〗,〖Sum〗on. 0 〖Prog〗on. Object 10 Number are between 1~9999999 0 ICode is Item-Code, which is usually printed as part of letters on barcode print. If the number of barcodes is 90001 default 2/5 or other custom numbers, ICode are printed as a part of barcodes. Please see details in chapter Barcode. 0 【0】,【1】: default weight unit; 【2】: default count unit; 【3】: kg weight unit; 【4】: g weight unit; 【5】: ton weight unit; 【6】: lb weight unit; 1 【7】: 500g weight unit; 【8】: 100g weight unit; Please see details in unit chapter. Default weight unit mean the unit used for display. And it is suggested for weight PLU. 0.00 16 Set U.Price 【3】 【0】 【00】F23 PLU.04 Go to Next Set cost Price 30.00 F23 PLU.05 Cost 0.00 【2】 【4】 【00】F23 PLU.05 Cost 24.00 0.000 【】 Go to Next 【】 F23 PLU.06 Tare Set Tare 【5】 F23 PLU.06 Tare Go to Next Set name Clear Original Text P ork Input number 2 Save edited text F23 PLU.14 【】 0 【Confirm】 En-1 【End】 Name 0 【Shift】 【p/P】EN-1 【o/O】【r/R】 EN-1 【k/K】 EN-1 【-】 1 P 4 rk 5 k- 6 -2 En-1 【Amend】 F23 PLU.14 When transferring PLU, it’s preset tare. Don’t have to input it. OK-Edit Input the names of goods. 0.005 Name This 【Amend】 is to save text edit in buffers instead of PLU. Please pay OK-Edit attention: If users need save it in PLU, users need to press【Amend】 again as the step below. 0 If to print the shelf life date Go to next 【】 F23 PLU.26 PS-UD Print shelf date 【1】 F23 PLU.26 PS-UD 1 Go to next 【】 F23 PLU.31 PC-UD 0 Input shelf days 【】 F23 PLU.31 PC-UD 3 Not Set 0 0.00 0.00 …… Save edited 【Amend】 F23 PLU.00 PLU Return to sale 【Cancel】 0.000 0.000 The cost is used to calculate the profits. Don’t have to input it. In consideration of there was a text, we suggest users press 【End】 before editing. If editing in the original text, users could use【】 【】 to move the position of cursor. EN-1 【2】 Preset U.Price in sale. Don't have to input it. Users can temporarily input it in sale. 0: Don't print PLU 31 invalid 1: Print. Continiune to set shelf days in PLU.31 Shelf days. 0 means intraday valid, followed like this. If all cargo for one scale use same shelf days, use Spec105 & Spec106 If other steps are still to be edited, users can use 【】【】 to switch steps. PLU10 is saved. 〖Sale〗,〖Sum〗 on N o t e 1 Except the parts which have been instructed, meaning of the other words are listed in List of Programme Interface in page 38. N o t e 2 PLU fast-prog is forbidden when Spec080=0. N o t e 3 Before you move to next step, the display of E1.01 Data Invalid means that the programme data you input is invalid. N o t e 4 The xx in PLU.xx means the content in the data which is marked with the number of xx in PLU fast 17 prog. N o t e 5 Xx is not continuous when users press【】and【】to select the programme content. There are two reasons. First reason is that the content in that part is meaningless. For example, tare is not present in count PLU programme. The second reason is that the content in that part is seldom used and has been set as non-programme content (Skip) in P3.01 and P3.02. Users could change that setting for personel usage. Please refer to corresponding chapters for details. 3.2 Fast-Prog of Shortcut Key for PLU Press 【F-Prog】+【SCxx】to enter PLU shortcut key programme. 【SCxx】could be one of 【SC1】~ 【SC63】. After pressing one key, Users can input the PLU which the pressed key appoints to .Then press 【Amend】to save and exit. Users can save without exit if they would like to go on to amend other shortcut keys. Press 【Confirm】 to save the change and press another 【SCxx】 to amend. The number of input PLU must exist. User can select existing PLU by pressing 【↑】【↓】. The process of programme is similar with scPLU programme in standard programme interface. Please refer to the process shown below. Example 3-2 Fast-Prog of Shortcut Key for PLU. Amend a shortcut key. Operations Keys 『Sale Idle』 Display Remarks Weight/ Change/ Single/ Tare Count U.Price Total 0.000 0.000 0.00 0.00 〖Sale〗, 〖Sum〗 on. PLU shortcut key programme, and the object is SC1 【F-Prog】+ 【SC1】 F14 Input PLU number 【1】【0】 F14 scPLU 0-01 10 Save directly 【Amend】 0.000 0.000 0.00 0.00 scPLU 0-01 0 〖Prog〗on. Key No. PLU No. Save to the scale. 〖Sale〗, 〖Sum〗 on N o t e 1 When Spec081=0, PLU shortcut-key fast-prog is forbidden. Example 3-3 Fast-Prog of Shortcut Key for PLU. Amend two or more shortcut keys. Operations Keys 『Sale Idle』 PLU shortcut key programme, and the object is SC1 【F-Prog】+ 【SC1】 Display Remarks Weight/ Change/ Single/ Tare Count U.Price Total 0.000 0.000 0.00 0.00 〖Sale〗, 〖Sum〗 on. F14 Input PLU number F14 【1】【0】 Confirm input 【Confirm】 F14 Set SC2 F14 【SC2】 Input PLU number F14 【1】【1】 Confirm input 【Confirm】 F14 Set Shift+SC1 【Shift】【SC1】 F14 Input PLU number 【1】【0】【0】 F14 scPLU 0-01 0 〖Prog〗on. Key No. PLU No. scPLU scPLU scPLU scPLU scPLU scPLU scPLU 0-01 -----0-02 0-02 -----1-01 1-01 10 ------- Save to temporary buffer. 0 11 ------- Save to temporary buffer. 0 100 18 Confirm input 【Confirm】 F14 scPLU ------ Save 【Amend】 0.000 0.000 0.00 Save to temporary buffer. The last confirm can be ------skipped. Press 【Amend】 directly. Save to the scale. 0.00 〖Sale〗, 〖Sum〗 on. N o t e 1 When Spec081=0, PLU shortcut key fast prog is forbidden. 3.3 Fast-Prog of Spec Parameters Press 【F-Prog】+【Prog】 to enter Spec parameters fast prog. Please select the number you want to edit by pressing 【←】 【→】. The second window shows the number of Spec which is being edited. The third window shows current parameters configuration. The fourth window shows the data which has been edited by users. Spec data parameters are made up of some number data. Refer to Definitions of Spec data parameters in page 73 in order to understand functions of these parameters. Press 【Amend】 to save and quit, or press【Cancel】to quit without saving. The process of programme is similar with Spec programme in standard programme interface. For details, please refer to the process shown below. Here, we are going to amend Spec000 to 2, Spec002 to 77 and Spec040 to 99. We would present the processes without discussing on the parameters we actually amend and their meanings. Example 3-4 Fast-Prog of Spec Parameters Operations Keys 『Sale Idle』 Tare 0.000 F12 Change to 2 【F-Prog】+ 【Prog】 【2】 Enter Spec002 【】【】 F12 Change to 77 Choose steps directly 【7】【7】 【×】 F12 Input step 40 【4】【0】 Confirm step Change to 99 Save and exit 【Confirm】 【9】【9】 【Amend】 Spec fast prog F12 F12 F12 0.000 Display Remarks Weight/ Change/ Single/ Count U.Price Total 0.000 0.00 0.00 〖Sale〗, 〖Sum〗on. SP.000 1 1 〖Prog〗on. Spec No. Origin Set Current Set SP.000 1 2 Using【】 【】 can only SP.002 0 0 get to amend items in Spec amend level 0. SP.002 0 77 Input 1-1 0 The input number of step must be in Spec amend Input 1-1 40 level 0 or 1. If not, the step cannot be reached. SP.040 0 0 SP.040 0 99 0.000 0.00 0.00 〖Sale〗, 〖Sum〗on. N o t e 1 Spec fast-prog programme is forbidden when Spec082 = 0. N o t e 2 Refer to Definitions of Spec data parameters in page 73 to know the definitions of data parameters . Note 3 Read the definition of the parameter before you change it. And don’ t change any unknown 19 parameters in Spec programme. N o t e 4 xxx in SP.xxx means the number of the data content in Spec programme. N o t e 5 xxx is not continuous when users press 【】and【】 to select the programme content. Users can only select Spec in level 0 by pressing 【】and【】. You have to input corresponding numbers afterting pressing 【×】to change Spec in level 1. And users cannot reach Spec in level 2 and level 3 because their data are involved with some specifications in measurement and other hardware fields. 3.4 Fast-Prog of Unit price After transfer PLU, press 【[email protected]】or【@Price】 to fast change this PLU’s price Example 3-5 Fast-Prog of unit price (Spec083=1) Display Operations Keys Weight/ Change/ Tare Count U.Price 0.000 0.000 0.00 『Sale Idle』 Transfer PLU10 【1】 5.00 【0】 【PLU】0.000 0.000 Input the ameneded 6.00 【6】【0】【0】 0.000 0.000 price Amend price Exit Long press【[email protected]】0.000 【Cancell】 0.000 Single/ Total 0.00 0.00 Remarks 〖Sale〗, 〖Sum〗on 0.00 0.000 6.00 0.00 0.000 0.00 0.00 PLU10’s default price change to 6.00 〖Sale〗, 〖Sum〗on. N o t e 1 When Spec083=1, the step to amend unit price please refer to step 2: first judge whetherthe input price in discount section or not, then set the accordant price as PLU’s default price Example 3-6 Fast-Prog of unit price (Spec083=2) Display Operations Keys Weight/ Change/ Tare Count U.Price 0.000 0.000 0.00 『『Sale Idle』 Transfer PLU10 【1】 5.00 【0】 【PLU】0.000 0.000 Input the ameneded 6.00 【6】【0】【0】 0.000 0.000 price Single/ Total 0.00 0.00 Remarks 〖Sale〗, 〖Sum〗on 0.00 Amend price 【[email protected]】 0.000 0.000 6.00 0.00 Exit 【Cancell】 0.000 0.000 0.00 0.00 PLU10’s default price change to 6.00 〖Sale〗, 〖Sum〗on. N o t e 1 When Spec083=2, during the unit price amend, it will not judge the rationality of the imput price and directly save as PLU’s default price 20 4 Sale Operations 4.1 Transfer and Lock of PLU PLU9999999 is temporary by-weight goods (Spec93), PLU9999998 is temporary by-count goods (Spec94), PLU9999997 is service charge (Spec95), user can use all other 7 digits PLU. 4.1.1 Transfer by Using PLU Number Example 4-1 Use PLU Number to Transfer Weight PLU Transfer PLU10, assuming PLU10 is a weight PLU with U.Price $2.00/kg and tare 0.100kg. Operations 『Sale Idle』 Input number Transfer PLU Clear current PLU Keys 【1】【0】 【PLU】 【Cancel】 Tare 0.000 0.000 0.100 0.000 Display Remarks Weight/ Change/ Single/ Count U.Price Total 0.000 0.00 0.00 〖Sale〗, 〖Sum〗 on. 0.000 0.10 0.00 -0.100 2.00 0.00 〖U.Price〗, 〖Single〗 on. 0.000 0.00 0.00 Example 4-2 Use PLU Number to Transfer Count PLU Transfer PLU11, assuming PLU11 is count PLU with U.Price $5.00/pc. Operations 『Sale Idle』 Input number Transfer PLU Clear current PLU Keys 【1】【1】 【PLU】 【Cancel】 Tare 0.000 0.000 0.000 Display Remarks Weight/ Change/ Single/ Count U.Price Total 0.000 0.00 0.00 〖Sale〗, 〖Sum〗 on. 0.000 0.11 0.00 5.00 0.00 〖U.Price〗, 〖Single〗 on. 0.000 0.00 0.00 4.1.2 Tranfer by Using PLU Shortcut Keys Example 4-3 Use PLU Shortcut Keys to Transfer Weight PLU Transfer SC1, assuming SC1=PLU10 and it is a weitht PLU with U.Price $2.00/kg and tare 0.100kg. Operations 『Sale Idle』 Input shortcut key Clear current PLU Keys 【SC1】 【Cancel】 Tare 0.000 0.100 0.000 Display Remarks Weight/ Change/ Single/ Count U.Price Total 0.000 0.00 0.00 〖Sale〗, 〖Sum〗 on. -0.100 2.00 0.00 〖U.Price〗, 〖Single〗 on. 0.000 0.00 0.00 〖Sum〗 on Example 4-4 Use PLU Shortcut Keys to Transfer Count PLU Transfer SC2, assuming SC2=PLU11 and it is count PLU with U.Price $5.00/pc. Operations Keys 『Sale Idle』 Input shortcut key Clear current PLU 【SC2】 【Cancel】 Display Remarks Weight/ Change/ Single/ Tare Count U.Price Total 0.000 0.000 0.00 0.00 〖Sale〗, 〖Sum〗 on. 5.00 0.00 〖U.Price〗, 〖Single〗 on. 0.000 0.000 0.00 0.00 〖Sum〗 on 21 4.1.3 Transfer Temporary Weight PLU Example 4-5 Transfer Temporary Weight PLU Operations 『Sale Idle』 Input Unit Price Set as a temporary weight PLU, Clear current PLU Display Remarks Weight/ Change/ Single/ Tare Count U.Price Total 0.000 0.000 0.00 0.00 〖Sale〗, 〖Sum〗 on. 1.30 0.00 【1】【3】【0】 0.000 0.000 Keys 【T-Sale】 0.000 0.000 1.30 0.00 〖U.Price〗, 〖Single〗 on. 【Cancel】 0.000 0.000 0.00 0.00 〖Sum〗 on. N o t e 1 Temporary weight PLU could be converted into count PLU if users press【×】or the weight is zero. N o t e 2 Temporary PLU’s number are decided by Spec093 (the default is 9999999) Example 4-6 Transfer Temporary Weight PLU with a Unit Conversion of the U.Price. Operations 『Sale Idle』 Input Unit Price Set as a temporary weight PLU, and convert its unit. Clear current PLU Display Remarks Weight/ Change/ Single/ Tare Count U.Price Total 0.000 0.000 0.00 0.00 〖Sale〗, 〖Sum〗 on. 1.70 0.00 【1】【7】【0】 0.000 0.000 Keys 【T-Sale】 0.000 0.000 3.40 0.00 〖U.Price〗, 〖Single〗 on. Convert unit between 500g/kg 【Cancel】 0.000 0.000 0.00 0.00 〖Sum〗 on. N o t e 1 Assume temporary weight unit is 500g (Spec210) and the unit of scale is kg. After input the U.Price of 1.70 and press 【T-Sale】, the U.Price is converted into 3.40. That means the conversion of the unit between 500g and kg is done. 4.1.4 Transfer Temporary Count PLU Example 4-7 Temporary PLU number is decided by Spec094(default 9999998) Operations 『Sale Idle』 Input Unit Price Set as a temporary count PLU Clear current PLU Display Keys Remarks Weight/ Change/ Single/ Tare Count U.Price Total 0.000 0.000 0.00 0.00 〖Sale〗, 〖Sum〗 on. 1.70 0.00 【1】【7】【0】 0.000 0.000 【×】 【Cancel】 0.000 1 1.70 1.70 〖U.Price〗, 〖Single〗 on. 0.000 0.00 0.00 〖Sum〗 on. 4.2 Manual Goods Sale 4.2.1 Sale and Print of Single Weight Goods Example 4-8 Sale for Single Weight goods Sell 1 kg PLU10 goods. Assume PLU10 is a weight PLU with U.Price is $2.00/kg and tare is 0.100kg. 22 Operations 『Sale Idle』 Transfer PLU10 Put on a weight Print Keys Tare 0.000 【1】 【0】 【PLU】0.100 0.100 0.000 【Print】 Display Remarks Weight/ Change/ Single/ Count U.Price Total 0.000 0.00 0.00 〖Sale〗, 〖Sum〗on. -0.100 2.00 0.00 〖U.Price〗,〖Single〗on. 0.900 2.00 1.80 0.000 0.00 0.00 Execute print. N o t e 1 Two qualifications are indispensable when directly print without accumulating: 1. Current accumulative buffer is empty, 2. The value of Spec060 is not 3 (forbid cashing mode with default zero change). N o t e 2 The system would have to wait for several seconds if users sell the weigh goods when the display of weight is not stable. If the display of weight is stable in the waiting time, system would sell the goods according to the operations. Please refer to Spec151 about the waiting time. 4.2.2 Sale and Print of Single Count Goods Example 4-9 Sale and Print for Single Count goods Sell 5pcs PLU11. Assume PLU11 is count PLU with U.Price is $5.00/pc. Display Operations Keys Remarks Weight/ Change/ Single/ Tare Count U.Price Total 0.000 0.000 0.00 0.00 〖Sale〗, 〖Sum〗on. 『Sale Idle』 Transfer PLU11 【1】 5.00 5.00 【1】 【PLU】 〖U.Price〗,〖Single〗on. Input PLU11 amount 【×】【5】 5 5.00 25.00 Print 0.000 0.000 0.00 0.00 Execute print. 【Print】 N o t e 1 Two qualifications are indispensable when directly print without accumulating: 1. Current accumulative buffer is empty, 2. The value of Spec060 is not set to be 3 (orbid cashing mode with default zero change). 4.2.3 No Weigh Sale for Weight Goods Example 4-10 No Weigh Sale for Weight PLU Operations Keys Tare 0.000 『Sale Idle』 Transfer PLU10 【1】 【0】 【PLU】0.100 Input T.Price of goods 【3】【8】【0】 0.100 Print 【Print】 0.000 Display Remarks Weight/ Change/ Single/ Count U.Price Total 0.000 0.00 0.00 〖Sale〗, 〖Sum〗on. -0.100 2.00 0.00 〖U.Price〗,〖Single〗on. -0.100 3.80 0.00 Execute print. Or press 0.000 0.00 0.00 【Confirm】 to do cumulate operations. N o t e 1 To execute no weigh sale, the value of Spec071 needs to be set to 1 while the default value is 0. N o t e 2 Temporary goods’ no weigh sale is not restricted by Spec071. And it could automatically convert to count sale for temporary count goods. 23 4.2.4 Sale and Print for Different Kinds of Goods (No Cashing Mode) Example 4-11 Sale and Print for Different Kinds of Goods (No Cashing Mode) Sell 1kg PLU10 and 5pcs PLU11. Assume PLU10 is weight PLU with U.Price $2.00/kg and tare 0.100kg, PLU11 is count PLU with U.Price $5.00/pc. Operations Keys Tare 0.000 『Sale Idle』 Transfer PLU10 【1】 【0】 【PLU】0.100 Put goods PLU10 on 0.100 Confirm a goods 【Confirm】 0.000 Take goods PLU10 off 0.000 Transfer PLU11 【1】 【1】 【PLU】 Input the number of 【×】【5】 PLU11 Confirm a goods 【Confirm】 0.000 Print 0.000 【Print】 Display Remarks Weight/ Change/ Single/ Count U.Price Total 0.000 0.00 0.00 〖Sale〗, 〖Sum〗on. -0.100 2.00 0.00 〖U.Price〗,〖Single〗on. 0.900 2.00 1.80 1.000 0.00 1.80 〖Sum〗on. 0.000 0.00 1.80 5.00 5.00 〖U.Price〗,〖Single〗on. 5 5.00 25.00 0.000 0.000 0.00 0.00 26.80 0.00 〖Sum〗on. Execute print. N o t e 1 Users can execute no cashing mode when the value of Spec60 is 0 or 1. 4.2.5 Sale and Print for Different Kinds of Goods (Cashing Mode, Input Payment) Example 4-12 Sale and Print for Different Kinds of Goods (Cashing Mode, Input Payment) Sell 1kg PLU10 and 5pcs PLU11. Assume PLU10 is weight PLU with U.Price $2.00/kg and tare 0.100kg, PLU11 is count PLU with U.Price $5.00/pc. Payment is $30. Operations Keys Tare 0.000 『Sale Idle』 Transfer PLU10 【1】 【0】 【PLU】0.100 Put goods PLU10 on 0.100 Confirm a goods 【Confirm】 0.000 Take goods PLU10 off 0.000 Transfer PLU11 【1】 【1】 【PLU】 Input the number of 【×】【5】 PLU11 Confirm a goods 【Confirm】 0.000 Input payment amount 【3】【0】【00】0.000 Print Display Remarks Weight/ Change/ Single/ Count U.Price Total 0.000 0.00 0.00 〖Sale〗, 〖Sum〗on. -0.100 2.00 0.00 〖U.Price〗,〖Single〗on. 0.900 2.00 1.80 1.000 0.00 1.80 〖Sum〗on. 0.000 0.00 1.80 5.00 5.00 〖U.Price〗,〖Single〗on. 5 5.00 25.00 0.000 0.000 0.00 30.00 26.80 26.80 3.20 26.80 0.00 0.00 【Print】 0.000 0.000 〖Sum〗on. 〖Change〗, 〖Sum〗 on. Execute print. Press any key to return. Or wait several seconds to exit according to the system setting of Spec066. N o t e 1 Cashing mode is available and change interface is displayed when the value of Spec060 is 1, 2, or 3. 24 4.2.6 Sale and Print for Different Kinds of Goods (Cashing Mode, Payment Equal to Price) Example 4-13 Sale and Print for Different Kinds of Goods (Cashing Mode, Payment Equal to Price) Sell 1kg PLU10 and 5pcs PLU11. Assume PLU10 is weight PLU with U.Price $2.00/kg and tare 0.100kg, PLU11 is count PLU with U.Price $5.00/pc. Payment is $26.80. Operations Keys Tare 0.000 『Sale Idle』 Transfer PLU10 【1】 【0】 【PLU】0.100 Put goods PLU10 on 0.100 Confirm a goods 【Confirm】 0.000 Take goods PLU10 off 0.000 Transfer PLU11 【1】 【1】 【PLU】 Input the number of 【×】【5】 PLU11 Confirm a goods 【Confirm】 0.000 If payment equal to 0.000 price, don’t input. Print Display Remarks Weight/ Change/ Single/ Count U.Price Total 0.000 0.00 0.00 〖Sale〗, 〖Sum〗on. -0.100 2.00 0.00 〖U.Price〗,〖Single〗on. 0.900 2.00 1.80 1.000 0.00 1.80 〖Sum〗on. 0.000 0.00 1.80 5.00 5.00 〖U.Price〗,〖Single〗on. 5 5.00 25.00 0.000 0.00 26.80 0.000 0.00 26.80 0.00 26.80 0.00 0.00 【Print】 0.000 0.000 〖Sum〗on. 〖Change〗, 〖Sum〗 on. Execute print. Press any key to return. Or wait several seconds to exit according to the system setting of Spec066. N o t e 1 Cashing mode without input the amount of payment is available and change interface is displayed when the value of Spec060is set to 2. 4.3 Discount Operations 4.3.1 U.Price Discount The data after discount should be within the discountable area. If the data exceeds the area, discount operation would fail. Example 4-14 Execute Discount in Subtraction Discount in U.Price: discount at the subtraction of $0.10/kg. Assume that PLU10 is weight PLU with U.Price $2.00/kg and tare 0.100kg. Operations Keys Tare 0.000 『Sale Idle』 Transfer PLU10 【1】 【0】 【PLU】0.100 Input discount data 【1】【0】 0.100 Discount in subtraction 【-Num】 0.100 Display Remarks Weight/ Change/ Single/ Count U.Price Total 0.000 0.00 0.00 〖Sale〗, 〖Sum〗on. -0.100 2.00 0.00 〖U.Price〗,〖Single〗on. -0.100 0.10 0.00 -0.100 1.90 0.00 〖Discount〗on. Example 4-15 Execute Discount at a Fixed Number Discount in U.Price: discount the U.Price to $1.80/kg. Assume that PLU10 is weight PLU with U.Price 25 $2.00/kg and tare 0.100kg. Operations Keys Tare Display Remarks Weight/ Change/ Single/ Count U.Price Total 0.000 0.00 0.00 〖Sale〗, 〖Sum〗on. -0.100 2.00 0.00 〖U.Price〗,〖Single〗on. -0.100 1.80 0.00 0.000 『Sale Idle』 Transfer PLU10 【1】 【0】 【PLU】0.100 Input discount data 【1】【8】【0】 0.100 Discount at a fixed 0.100 -0.100 【[email protected]】 number 1.80 0.00 〖Discount〗on. 4.3.2 T.Price Discount The operations of T.Price discount and U.Price discount are the same. Under the condition that PLU is not transferred and with accumulative buffers, execute discount operation is to discount on T.Price. The processes are not repeated here. The limit of discount on T.Price is a accumulative value of U.Price discount limits of all goods. 4.3.3 ±% price 【±%】key and【-%】ket are the same key. When ±% price, the data object is floating-point decimal fraction. For the same 5% discount, if input data is two digit decimal fraction, you need input 500; if with three digit decimal fraction, then input 5000. you can long press【Shift】or【Fast prog】+【Shift】to change the decimal point site. Example 4-16 Input data to execute ±% price U.Price-%price: at the percentage of 95%, as 100.00 5.00 . Assume that PLU10 is weight PLU with 100.00 U.Price $2.00/kg and tare 0.100kg. Operations Keys Tare 0.000 『Sale Idle』 Transfer PLU10 【1】 【0】 【PLU】0.100 Input discount data 【5】【00】 0.100 Discount in percentage 0.100 【±%】 Display Remarks Weight/ Change/ Single/ Count U.Price Total 0.000 0.00 0.00 〖Sale〗, 〖Sum〗on. -0.100 2.00 0.00 〖U.Price〗,〖Single〗on. -0.100 5.00 0.00 -0.100 1.90 0.00 〖Discount〗on. N o t e 1 Default percentage discount is subtraction discount( Spec113=0) , if need to change the default discount to additive, change Spec113=1 Example 4-17 Enterinterface and execute ±%price Unit price+%price,charge 10% more.Assume that PLU10 is weight PLU with U.Price $2.00/kg and tare 0.100kg. Display Operations Keys Weight/ Change/ Tare Count U.Price 0.000 0.000 0.00 『Sale Idle』 Transfer PLU10 【1】 2.00 【0】 【PLU】0.100 -0.100 Single/ Total 0.00 0.00 Remarks 〖Sale〗, 〖Sum〗on. 〖U.Price〗,〖Single〗on. 26 Enter ±%price interface 【±%】 Amend to +% 【±%】 Input 10% 【1】【0】【00】 Execute +%price 【Confirm】 0.100 -0.100 Sub-P - 0.00 Add-P Add-P 2.20 0.00 10.00 0.00 without any number before 【±%】 Sub-P means it is -% 〖Discount〗on. N o t e 1 Press【±%】repeatedly to amend the operation symbol to ’+’ or’-’. Example 4-18 Directly execute default ±%price(Spec114) Unit price+%price( Spec113=1) , charge additional 20%( Spec114=20) . Assume that PLU10 is weight PLU with U.Price $2.00/kg and tare 0.100kg. Display Operations Keys Weight/ Change/ Tare Count U.Price 0.000 0.000 0.00 『Sale Idle』 Transfer PLU10 【1】 2.00 【0】 【PLU】0.100 -0.100 Execute default ±%price 【±%】 0.100 -0.100 2.40 Single/ Total 0.00 0.00 0.00 Remarks 〖Sale〗, 〖Sum〗on. 〖U.Price〗,〖Single〗on. without any number before 【±%】 〖Discount〗on. N o t e 1 When execute default ±%price, the +/- are decided by Spec113, default price is decided by Spec114 4.3.4 Auto Discount When goods are working on auto discount, the price of activated PLU would change in real-time according to the settings and system would shield any actions of manual change on the price. Assume PLU20 is at the U.Price $10.00/kg. U.Price goes to $9.00/kg when sale weight is more than 1kg and U.Price goes to $8.00/kg when sale weight is more than 2kg. The change of U.Price of this PLU is shown below: Example 4-19 Auto Discount Operations Keys Tare 0.000 『Sale Idle』 Transfer PLU20 【2】 【0】 【PLU】0.000 Put weight 1.5kg 0.000 Add weight 1kg 0.000 Take off all weight and 0.000 put on weight 0.5kg. Display Remarks Weight/ Change/ Single/ Count U.Price Total 0.000 0.00 0.00 〖Sale〗, 〖Sum〗on. 0.000 10.00 0.00 〖U.Price〗,〖Single〗on. 1.500 9.00 13.50 〖Discount〗on. 2.500 8.00 20.00 〖Discount〗on. 0.500 10.00 5.00 〖Discount〗off. N o t e 1 All details about the auto discount setting of PLU, please read definitions of auto discount settings in List of Programme Interface on page 38 and Spec115 carefully. Suggest users edit the content on PC. 27 4.3.5 Unit Conversion of Temporary U.Price Example 4-20 Unit Conversion of Temporary U.Price Operations Display Remarks Weight/ Change/ Single/ Tare Count U.Price Total 0.000 0.000 0.00 0.00 〖Sale〗, 〖Sum〗on. 2.00 0.00 〖U.Price〗,〖Single〗on. 【1】 【0】 【PLU】0.100 -0.100 Keys 『Sale Idle』 Transfer PLU10 Input a Temporary U.Price with the unit 【1】【8】【0】 0.100 of 500g Unit conversion 【T-Sale】 0.100 -0.100 1.80 0.00 -0.100 3.60 0.00 N o t e 1 Spec210 is 7 (500g), and kg is the measure unit of the scale. N o t e 2 Spec073 is 1: Put 【T-Sale】 into use of 【Unit Conversion】. 4.4 Setting and Lock of Tare 4.4.1 Weight Tare Example 4-21 Weight Tare Operations 『Sale Idle』 Put on tare object Tare Take off tare object Cancel tare Keys 【Tare】 【Tare】 Tare 0.000 0.000 0.050 0.050 0.000 Display Remarks Weight/ Change/ Single/ Count U.Price Total 0.000 0.00 0.00 〖Sale〗, 〖Sum〗on. 0.050 0.00 0.00 0.000 0.00 0.00 -0.050 0.00 0.00 0.000 0.00 0.00 N o t e 1 If users need to cancel tare, current total weight should be 0 and users do not input any number. 4.4.2 Number Tare Example 4-22 Number Tare Operations Keys 『Sale Idle』 Input tare tare Cancel tare 【3】【2】 【Tare】 【Tare】 Tare 0.000 0.000 0.032 0.000 Display Remarks Weight/ Change/ Single/ Count U.Price Total 0.000 0.00 0.00 〖Sale〗, 〖Sum〗on. 0.000 0.32 0.00 -0.032 0.00 0.00 0.000 0.00 0.00 N o t e 1 Spec067 is 0: Number tare is forbidden N o t e 2 Spec067 is 1: Use absolute value as tare. For example, when the tare definition is 0.001 and input is 0.32, tare is 0.032. N o t e 3 Spec067 is 2: Use floating-point values as tare. For example, input 0.32 and after tare users would get 0.320. N o t e 4 When there are numbers in input window and total weight is not 0, weight tare is the priority. 28 4.4.3 Lock and Unlock of Tare Example 4-23 Tare Lock and Unlock Operations Keys Display Weight/ Change/ Single/ Tare Count U.Price Total Remarks 〖Lock Tare〗 on Lock tare Long Press【Tare】 Other operations Unlock tare Long Press【Tare】 〖Lock Tare〗 off N o t e 1 When you long press 【Tare】, you can hear one beep first (beep for correctness or error) . Hold pressing for 4 seconds you will hear the beep for correctness. N o t e 2 Once tare locked, it cannot be changed or cleared automatically. Only manual tare can change tare. N o t e 3 Once tare locked, it cannot be unlocked unless users unlock tare manually. 4.5 Special sale mode Except general sale mode, scale also with other 4 special sale mode: batch print model, pre-packing mode, lock PLU mode, auto print mode 4.5.1 Enter and Exit of Special sale Mode Example 4-24 Single key select of sale mode Operations Display Weight/ Change/ Single/ Tare Count U.Price Total Keys Remarks 『Sale Idle』 Enter Auto Mode 【Auto Mode】 Exit Auto Mode 【Auto Mode】 Enter prepack mode 【Prepack Mode】 Exit prepack mode 【Prepack Mode】 Enter auto print mode 【Auto print】 Exit auto print mode 【Auto print】 N o t e 1 【Auto Mode】key related mode are decided by Spec78 N o t e 2 Only for super market version scale with the 【Prepack Mode】【Auto print】and【lock PLU】key N o t e 3 Under one special mode, press special mode key will exit present mode and back to general sale mode Example 4-25 Interface select sale mode Operations Keys Display Weight/ Change/ Single/ Tare Count U.Price Total Remarks 『Sale Idle』 Enter Mode select interface Long press 【Auto Mode】 【0】: General mode 【1】: Batch print mode Mode 0 Normal 【2】: Prepack mode 【3】: Lock PLU mode 【4】: Auto print mode 29 Select auto print mode Can use【←】 【→】 【COnfirm】 to select mode 【4】 『Auto print mode』 N o t e 1 Menu of sale mode selection enable by Spec79 4.5.2 Sale under batch print mode Example 4-26 Batch Print mode Batch print mode. Assume PLU11 is weight PLU with U.Price $2.00/kg and tare 0.100kg. Operations Keys 『Sale Idle』 Display Remarks Weight/ Change/ Single/ Tare Count U.Price Total 0.000 0.000 0.00 0.00 〖Sale〗, 〖Sum〗on. Long press 【Auto Mode】 Enter batch print mode 0.000 【1】 Transfer PLU11 【1】 【1】 【PLU】 Input quantity 【×】【5】 Confirm sale object 【Print】 Input the number of 【1】【0】 print copies Confirm the number 【Confirm】 Mode 0 Normal Enter mode select 0.000 5 Input 0.00 5.00 5.00 Count Input Count 0.00 〖Auto Mode〗on 5.00 〖U.Price〗,〖Single〗on. 25.00 If number is 1, omit this step 0 10 Press 【Cancel】 to exit print in midway. Print 10 copies Print ends Exit quantity input Exit PLU Exit Auto Mode 5 0.000 0.000 0.000 0.000 5.00 5.00 0.00 0.00 5.00 25.00 0.00 0.00 0.000 〖Sum〗 on. 0.000 〖Auto Mode〗off. N o t e 1 Under Batch print mode, user can accumulate, after accumulate , press【Print】select the print times 4.5.3 Sale under prepack mode (only for weight PLU) Example 4-27 Prepack mode(only for weight PLU) Prepack mode for weight PLU. Assume PLU10 is weight PLU with U.Price $2.00/kg and tare 0.100kg. Operations 『Sale Idle』 Keys Display Remarks Weight/ Change/ Single/ Tare Count U.Price Total 0.000 0.000 0.00 0.00 〖Sale〗, 〖Sum〗on. Long press 【Auto Mode】 Enter prepack mode 0.000 【1】 Transfer PLU10 【1】 【0】 【PLU】0.100 Put goods PLU10 on 0.100 After weight is stable. 0.100 Take goods PLU10 off 0.100 Put goods PLU10 on 0.100 After weight is stable. 0.100 Take goods PLU10 off 0.100 Mode 0 Normal Enter mode select 0.000 -0.100 0.900 0.900 -0.100 1.900 1.900 -0.100 0.00 2.00 2.00 0.00 0.00 2.00 0.00 0.00 0.00 0.00 1.80 1.80 0.00 3.80 0.00 0.00 〖Auto Mode〗,〖lock PLU〗on 〖U.Price〗,〖Single〗on. Print automatically. Print automatically. 30 ………. Exit PLU Exit Auto Mode 【Cancel】 【Auto Mode】 〖Sum〗 on. 〖Auto Mode〗〖 , lock PLU〗off. N o t e 1 Pre-packing enable if Spec078 is set to 2. 4.5.4 Sale under Lock PLU mode Under lock PLU mode, cargo cannot be accumulated and after finish the sale, will not exit the present PLU automatically. 4.5.5 Auto print mode (only for weight PLU) Under auto mode, when the weight is stable, print automatically. 4.6 Operations of Sale Buffers 4.6.1 Switch of Sale Buffers Example 4-28 Switch of Sale Buffers Operations Keys Display Weight/ Change/ Single/ Tare Count U.Price Total 『Sale Idle』 0.000 0.000 Default buffer V1 Transfer PLU10 【1】 【0】 【PLU】0.100 -0.100 Put goods PLU10 on 0.100 0.900 Confirm a goods 【Confirm】 0.000 1.000 Service other customers, for current customer …… delay checking out 0.00 2.00 2.00 0.00 Remarks 〖Sale〗, 〖Sum〗on. 〖V1〗 glittering. 0.00 〖U.Price〗,〖Single〗 on. 1.80 1.80 〖Sum〗 on. 0.00 0.000 0.000 0.00 〖V1〗on: means that there is sale data in the buffer. 0.00 〖V2〗glittering: means that buffer『V2』is working Execute sales. Users can switch to V3, V4 …… according to demands. Continue sale buffered in …… V1 for customer return. Switch buffer V1 0.000 【V1】 Transfer PLU11 【1】 【1】 【PLU】 Input PLU11 amount 【×】【5】 Confirm a goods 【Confirm】 0.000 If payment is equal to 0.000 total, don’t input. 1.000 5 0.000 0.00 5.00 5.00 0.00 1.80 〖V1〗 glittering. 5.00 〖U.Price〗,〖Single〗 on. 25.00 26.80 〖Sum〗 on. 0.000 0.00 26.80 0.00 26.80 Switch buffer V2 Print 【V2】 【Print】 〖Change〗, 〖Sum〗 on. Execute print. Finished sales buffered in V2~V4. 31 4.6.2 Cancel Sale Data in Sale Buffers Example 4-29 Clear All Data in Current Sale Buffers Operations Keys Tare 0.000 『Sale Idle』 Transfer PLU10 【1】 【0】 【PLU】0.100 Put goods PLU10 on 0.100 Confirm a goods 【Confirm】 0.000 Take goods PLU10 off 0.000 Transfer PLU11 【1】 【1】 【PLU】 Input PLU11 amount 【×】【5】 Confirm a goods 【Confirm】 0.000 02.00 Enter cancel interface 【Amend】 Total Clear all data 【Confirm】 0.000 Display Remarks Weight/ Change/ Single/ Count U.Price Total 0.000 0.00 0.00 〖Sale〗, 〖Sum〗on. -0.100 2.00 0.00 〖U.Price〗,〖Single〗 on. 0.900 2.00 1.80 1.000 0.00 1.80 〖Sum〗 on. 0.000 0.00 1.80 5.00 5.00 〖U.Price〗,〖Single〗 on. 5 5.00 25.00 0.000 0.00 26.80 〖Sum〗 on. 6 26.80 Piece Total 〖Sum〗 on. Number Price 0.000 0.00 0.00 〖Sum〗 on. Example 4-30 Clear One Goods in Current Sale Buffer Operations Keys Tare 0.000 『Sale Idle』 Transfer PLU10 【1】 【0】 【PLU】0.100 Put goods PLU10 on 0.100 Confirm a goods 【Confirm】 0.000 Take goods PLU10 off 0.000 Transfer PLU11 【1】 【1】 【PLU】 Input PLU11 amount 【×】【5】 Confirm a goods 【Confirm】 0.000 02.00 Enter amend interface 【Amend】 Total Use 【←】【→】to select goods Confirm amendment 02.01 【→】 Goods 1 【Confirm】 0.000 Display Remarks Weight/ Change/ Single/ Count U.Price Total 0.000 0.00 0.00 〖Sale〗, 〖Sum〗on. -0.100 2.00 0.00 〖U.Price〗,〖Single〗 on. 0.900 2.00 1.80 1.000 0.00 1.80 〖Sum〗 on. 0.000 0.00 1.80 5.00 5.00 〖U.Price〗,〖Single〗 on. 5 5.00 25.00 0.000 0.00 26.80 〖Sum〗 on. 6 26.80 Piece Total 〖Sum〗 on. Number Price 0.900 10 1.80 PLU Single 〖Single〗on. Amount Number Price 0.000 0.00 25.00 〖Sum〗 on. N o t e 1 In amend window: the window of tare is in the form of xx xx. The first part shows accumulative times; the latter part is the object to be amended. 00 is total and 01~31 are accumulative number. N o t e 2 If users amend the total, the whole deal is cleared. N o t e 3 If users amend xx goods, information of xx goods is cleared. And if there was a T.Price discount, T.Price discount information is cleared. T.Price will be calculated based on U.Price (or discounted U.Price) and amount of sold goods. N o t e 4 If T.Price is selected, the window of 『Weight/Count』 will display piece number of sold goods. The definition of piece number is: 5 count goods add 5 and each weight goods add 1. 32 4.7 Salesman and Waiter 4.7.1 Personnel Information Please refer to Salesman Programme in page 56. Salesman and waiter use the same personnel sheet. 4.7.2 Salesman Function Salesman Function is disabled as default. User can enable it at Spec135. Normally, Set Spec135=2 or 4. Only non-zero password Personnel can login as salesman when Spec135=4 or 5. User need to input salesman’s number and password in the login menu before get into sale menu when salesman function is enable. 4.7.3 Waiter Function Do not enable in the common version, and do not have corresponding key. 4.8 Inquiry of Sale Records and Markers of Returns of Goods Mark the tenth item in the sale record as return of goods. Example 4-31 Inquiry of Sale Records and Markers of Returns of Goods Operations Keys 『Sale Idle』 Tare 0.000 2 Note 2 Enter『Sale Records』 Other information of record items Other information of record items Other information of record items See previous record See record 10 Other information of record items Other information of record items Other information of record items Sign as a return goods Long Press 【Amend】 Display Remarks Weight/ Change/ Single/ Count U.Price Total 0.000 0.00 0.00 〖Sale〗, 〖Sum〗on. 5 11 25.00 If there is data in current buffer, system would first enter PLU Amount Price buffer interface, long press will Number enter current interface,. If there is no sale records, it will not enter this interface Information Page 1 Sale time of records. 05 24 09 08 59 W-6 Information Page 2 Note 1 15 15 Note 3 Information Page 3 Note 4 【↓】 2008 【↓】 Note 5 【↓】 02.02 5 11 25.00 【←】 【×】 【1】【0】 【Confirm】 02.01 0.900 Input 10 1-1 1.80 0 01.01 1.000 12 2008 05 24 08 01 39 W-6 15 10 【↓】 【↓】 Switch to the 4.00 number record. 【↓】 01.01 1.000 12 4.00 【F-Prog】+ 【Amend】 01.01 1.000 12 4.00 10 here number. is the appointed appointed 33 Return to sale mode 【Cancel】 0.000 0.000 0.00 0.00 〖Sale〗, 〖Sum〗on. N o t e 1 The record are divided into deal head record and deal detailed record, deal head record include deal data of FID , SID, deal discount sum,etc; deal detailed record include the detailed cargo deal information N o t e 2 When display deal head record, here display ‘----’, when display deal detailed record, here display this goods are which number cargo N o t e 3 When display deal head record, here display this deal’s SID (code ID, refer to Spec140), when display deal detailed record, here is blank N o t e 4 The number shown in the window of change / U.Price is the amount of sale record stored in the scale. When the number is close to 8000, the scale would delete the earlist records automaticlly. And Single/Total Price window shows the sequence number of this record in all the records N o t e 5 If present record are marked as goods return, the window will display“-RT-”. 4.9 Manual Weight 4.9.1 Manual Sale of Manual Weight Entry Example 4-32 Manual Sale of Manual Weight Entry Sell 1 kg PLU10 goods. Assume PLU10 is a weight PLU with U.Price is $2.00/kg and tare is 0.100kg. Operations Keys Tare 0.000 『Sale Idle』 Transfer PLU10 【1】【0】【PLU】0.100 Manual weight entry 【Manual Weight】 Weight data 【1】【0】【00】 Put on a weight ---【Confirm】 Print 0.000 【Print】 Display Remarks Weight/ Change/ Single/ Count U.Price Total 0.000 0.00 0.00 〖Sale〗, 〖Sum〗on. -0.100 2.00 0.00 〖U.Price〗,〖Single〗on. Man Weight 0.000 Man Weight 1.000 1.000 2.00 2.00 【Manual Weight】on 0.000 0.00 0.00 Execute print. N o t e 1 Manual weight entry need Spec077 set to non-zero (1, 2 or 3 are all ok). N o t e 2 Manual weight entry can be executed only if weight keeps at zero and stable. N o t e 3 In manual weight sale process, tare function is forbidden, 〖Manual Weight〗 on, and “ManWT” is printed before weight data. 4.10 Bar code printing and scanning 4.10.1 Exterior bar code Exterior bar code is EAN/UPC barcode normally, which is defined by the standards organisation GS1. If user look for commodity by exterior bar code, user need to input the commodity’s bar code to PLU’s Index Barcode, after the scanner scan the bar code, it will search and transfer the same index PLU auotmatically. When user edit the PLU on the scale, scan the exterior bar code during the PLU numbwe step, it will transfer the PLU related to the exterior bar code; if scans the exterior bar code in other step, it will consider this bar code as present PLU’s index barcode. 34 4.10.2 Interior bar code Interior bar code is user appointed barcode format and only used in small are, generally used for communication between barcode scale and cash machine like cash register scale or cash register machine. In the rule of EAN-UCC, define the prefix code 20-29 as shop inside use to avoid the repeatance with EAN code. So, if user uses both exterior and interior bar code, then interior bar code ‘s prefix must inside 20-29. To meet the different request, the interior bar code’s format can be defined by user, but the print device (barcode label scale) and scan device (cash register scale or cash register) must with the same format, then the interior bad coe can be exactly recognised 35 5 Programme Operations 5.1 Please Read this Part First For ordinary users, they can use 3 kinds of Fast Progs in Fast Prog in chaper 3 to handle most applications. There are detailed programme operations of the scale in this chapter, as well as examples for users. But some parts of programme content are very complicated such as print format edit and barcode format edit. Devisers suggest users use company offered software when users are in need of these functions. The company software offers users a convenient interface to edit all the working parameters and sale data of the scale. The setting data can be downloaded from Ethernet (real-time download), or transferred in the form of files by USB flash disk (Users edit the data on PC and store data in USB flash disk, then download data to scale from USB flash disk.). Devisers are convinced that it’s easy to learn to use the company software. As long as users own basic computer operation knewledge and learn with user menual of this software (User menual would be installed with the software), users can operate the software in a very short time. If users cannot use computer and are still in need of complicated programme operations, users can write down the demands and send to us. If computers cannot be used in users’ circumstances, and users are indeed in need of functions of this part, please read content in this chapter carefully. In consideration of too much content, detailed example instructions of all operations will not be provided in some chapters. But all the functions are instructed in words and processes are arranged in sequence of steps. Users should read Tree-shaped Design of Edit Steps and Frequently-used Keys in Prog Interfaces first carefully. Then do programme operations according to instructions in List of Programme Interface and corresponding chapters on the basis of fully understanding of these two parts. 5.2 Basic Operations in Programme Interface 5.2.1 Tree-shaped Design of Edit Steps P1 Prog Menu P2 P3 P4 P11 Time P12 Spec P13 Sring P14 PLU Shortcut P21 Dept. P22 Class P23 PLU P24 Unit P25 Barcode P26 Print format P27 P31 P32 Salesman PLU Prog steps PLU F-Prog steps P33 Delete Sale data Communications P41 (Commu) P42 USB flash disk Ethernet Scale Paramete (TM-Set) Sale Data (DT-Set) Data Assistant (DT-Ass) Press 【Prog】 first enter P1; Use【←】 and 【→】to select one of P1 to P5. Use 【Confirm】 to select corresponding programme operations; Or press【1】~【5】directly to enter P1~ P5; Then use the way to go to Next. The operations are a little different in various programme operations. But they are almost designed into tree-shaped. Instructions and examples about each part would be in following chapters. . Note: Communication ways of P4 depend on the hardware of the scale. And basic 36 P43 P44 Hardware Assistant P51 P5 (HWAss) P52 RS232 USB slave Set the passwords Factory default hardware only has P41. P1.-TM-Set Fast Prog Time Spec String ScPLU Dept. Class PLU Bcode Label Sales P2.-DT-Set Unit ProgMenu P3.-DT-Ass SK-PLU SKFPLU Delete P4.-Commu U-Disk Ethnet RS232 USlave P5.-HW-Ass Set-PW TMS-DF Note: Hardware information must be operated in this machine. Picture 5-1 Sketch map of tree-shaped design of edit interface 5.2.2 Frequently-used Keys in Prog Interfaces 【Amend】: Save the amended content and go back to previous interface. If operation is in DTSet, go 37 back to step 0 after save and wait for new number to be input to amend. 【Cancel】: Don’t save and go back to previous interface. 【Confirm】: Get into next step to edit. Such as enter P3 by pressing 【Confirm】 when operation is in P31. And press 【Confirm】 to enter certain edit interface when operation is in text edit or in edit interface of print format. Then press 【Amend】 to save and exit, or press 【Cancel】 to exit without saving. 【←】、【→】: Steps selection. Such as press 【←】 and【→】 to select steps P21~ P27 【↑】、 【↓】: Press 【↑】 【↓】 to select previous or next valid data when amending data in programme. And its function is the same as 【←】【→】 in some interfaces when no data is to be amended. 【0】~【9】 、00: Input corresponding numbers. 【back】: Delete the last digit number. 【×】: For so many steps to select in processes of Spec and DTSet edit operations in TMSet, users can use 【×】 to select step to edit. There would be a hint for you to input the step number you want to select after you press【×】. Please input the number and press 【Confirm】. 5.2.3 List of Programme Interface Menus P1 Menu Prompt TMSet Instructions P11 TMSet Time P12 TMSet Spec Spec Parameters setting P12 SP.000 …… …… P12 SP.249 P13 TMSet Spec 000 …… …… Spec 249 ST.000 ShopN String 0: Store name P13 ST.001 ScaleN String 1: Device name P13 ST.002 MnyPre String 2: Prefix of Money Unit P13 ST.003 MnySuf String 3: Suffix of Money Unit P2 DTSet Scale Data setting DPT.00 NoSet Dept.0: Number P21 DPT.01 Name Dept.1: Name DTSet Class Class P22 CLS.00 NoSet Class 0: Number P22 CLS.01 Name Class 1: Name P22 CLS.00 Dept Class 2: Dept. that it belong to DTSet PLU PLU P23 Definitions of Spec data parameters Dept Dept. setting P21 P22 Spec 000~249, see details in chapter 7.2 TMSet scPLU PLU shortcut key setting DTSet P21 State String Text setting P13 P14 Remarks BarCode Scale Setting Available dept edit number: 10~99. Available class edit number 10~99 P23 PLU.00 NoSet PLU 0: Number Available PLU edit number 1~9999999. P23 PLU.01 ICode PLU 1: Item Code Be printed with barcodes. P23 PLU.02 Index PLU 2: Index for exterior barcode 38 Menus Menu Prompt Instructions Remarks State 1 is default weight unit; 2 is default weight unit; 3 is kg weight unit; P23 PLU.03 Unit PLU 3: Unit 4 is g weight unit; 5 is ton weight unit; 6 is pound weight unit; 7 is 500g weight unit; 8 is 100g weight unit. P23 PLU.04 Price PLU 4: U.Price P23 PLU.05 Cost PLU 5: Cost P23 PLU.06 Tare PLU 6: Tare P23 PLU.07 Lab-1 PLU 7: Print format number of 1st bill P23 PLU.08 BarT1 PLU 8: Barcode number of 1st bill P23 PLU.09 BarF1 PLU 9: Barcode flag of bill 1st bill P23 PLU.10 Lab-2 PLU 10: Print format number of 2nd bill P23 PLU.11 BarT2 PLU 11: Barcode number of 2nd bill P23 PLU.12 BarF2 PLU 12: Barcode flag of 2nd bill P23 PLU.13 P23 PLU.14 Name PLU 14: Goods name P23 PLU.15 Des-1 PLU 15: Goods postil 1 P23 PLU.16 Des-2 PLU 16: Goods postil2 P23 PLU.17 Des-3 PLU 17: Goods postil3 P23 PLU.18 Des-4 PLU 18: Goods postil4 P23 PLU.19 Des-5 PLU 19: Goods postil5 P23 PLU.20 Des-6 PLU 20: Goods postil6 P23 PLU.21 Des-7 PLU 21: Goods postil7 P23 PLU.22 PS-SD PLU 22: Sale date print Class PLU 13: class that it belongs to 0: not print, 1: print. 0: not print, 1: print at appointed time, P23 PLU.23 PS-ST PLU 23: Sale time print P23 PLU.24 PS-PD PLU 24: Packing date print P23 PLU.25 PS-PT PLU 25: Packing time print P23 PLU.26 PS-UD PLU 26: Shelf date print 0: not print, 1: print. P23 PLU.27 PC-SD PLU 27: Sale days data Number of days after current day. P23 PLU.28 PC-ST PLU 28: Sale time data Appointed time for print. P23 PLU.29 PC-PD PLU 29: Packing days data Number of days after current day. 2: print printing time. 0: not print, 1: print. 0: not print, 1: print at appointed time, 2: print printing time. P23 PLU.30 PC-PT PLU 30: Packing time data Appointed time for print. P23 PLU.31 PC-UD PLU 31: Shelf days data Number of days after current day. P23 PLU.32 DF-D PLU 32: Manual discount lower limit 0: use system setting; 1: no lower limit; 2: Take original cost as lower limit; 3: Take PLU.34 as lower limit. 0: use system setting; 1: no upper limit; P23 PLU.33 DF-U PLU 33: Manual discount upper limit 2: Take original U.Price as upper limit; 3: Take PLU.35 as upper limit. P23 PLU.34 DF-DN P23 PLU.35 DF-UN PLU 34: Value of manual discount lower limit PLU 35: Value of manual discount upper limit Activated when DF_D=3. Activated when DF_D=3. 39 Menus P23 Menu Prompt Instructions PLU.36 DA-S0 PLU 36: Customize 0 of auto disount Remarks State 0: not activate; 1: discount on count; 2: discount on periods of time. Sunday: 1, Monday: 2, Tuesday: 4 Wednesday: 8, Thursday: 16, Friday: 32 Saturday: 64. When this customization discount P23 PLU.37 DA-W0 PLU 37: Activation day of the customize needs to be activated at some certain days, input add-up number of these days here. To input 127 means that the discount is activated all the days. To input 1+64=65 if the discount is only activated at Saturday or Sunday. Execute this discount way in this customization PLU 38: The Lower limit of P23 PLU.38 DA-D0 customization activation period Start at this point (include this point) activation period. Input weight/count according to the unit of PLU when discount on amount. When inputing count, 10 goods needs to input 10.000 or move decimal (long press 【Shift】 or 【F-Prog】+ PLU 39: The upper limit of P23 PLU.39 DA-U0 customization activation period End at this point (not include this point) 【Shift】) to input 10. Avoid inputing 0.010 for 10 pcs. When discount on time, the format of input time is HHMM. If the time is 20: 30, users need to move decimal to input 2030. If number is positive, discount number would replace U.Price. If number is minus, new P23 PLU.40 DA-N0 PLU 40: Discount Price of customize U.Price is the price that subtracts the input number from former U.Price. But minus values cannot be input in the scale. P23 PLU.41 DA-S1 PLU 41: Customize 1 of auto disount P23 PLU.42 DA-W1 PLU 42: Activation day of the customize P23 PLU.43 DA-D1 P23 PLU.44 DA-U1 P23 PLU.45 DA-N1 PLU 45: Discount Price of customize P23 PLU.46 DA-S2 PLU 46: Customize 2 of auto disount P23 PLU.47 DA-W2 PLU 47: Activation day of the customize P23 PLU.48 DA-D2 P23 PLU.49 DA-U2 P23 PLU.50 DA-N2 PLU 50: Discount Price of customize P23 PLU.51 DA-S3 PLU 51: Customize 3 of auto disount P23 PLU.52 DA-W3 PLU 52: Activation day of the customize P23 PLU.53 DA-D3 PLU 43: The Lower limit of It’s the same as last customize discount. customization activation period After the edit of last customize discount it PLU 44: The upper limit of can be edited. customization activation period PLU 48: The Lower limit of It’s the same as last customize discount. customization activation period After the edit of last customize discount it PLU 49: The upper limit of can be edited. customization activation period PLU 53: The Lower limit of It’s the same as last customize discount. customization activation period After the edit of last customize discount it PLU 54: The upper limit of can be edited. P23 PLU.54 DA-U3 P23 PLU.55 DA-N3 PLU 55: Discount Price of customize customization activation period 40 Menus Menu Prompt Instructions Remarks State 0: excute tax rate according to Spec 116,117 1: tax free price mode P23 PLU56 Tax-S PLU56: tax rate sort 2:: tax free price mode, input unit price is price duty paid 3.with tax price mode P23 P24 PLU.57 Tax-D PLU57: tax rate percentage DTSet Unit 0.01% tax rate,17% input 1700 Unit P24 UNT.00 NoSet Unit 0: Number P24 UNT.01 Name Unit 1: Name P24 UNT.04 PUnit Unit 4: Measure Mode(just open 1 is default weight unit, weighing mode) 2 is default count unit, Not Open In weighing mode, means how much gram as P24 UNT.05 Pack Unit 5: Packing one packing In counting mode, means how many pcs as one Not Open packing P25 DTSet Bcode Barcode P25 BAR.00 NoSet Barcode 0: Number P25 BAR.01 Name Barcode 1: Name P25 BAR.02 Edited number of barcode when leaving factory are 1~9. Available barcode edit number 10~99. Type Barcode 2: Type P25 BAR.03 Check Barcode 3: Checkout P25 BAR.04 NCon1 Barcode 4: Constant number 1 P25 BAR.05 NCon2 Barcode 5: Constant number 2 Please pay attention that edit content should P25 BAR.05 Des Barcode 6: Data format description accord with certain format: refer to chapter of barcode. P26 DTSet PSets Print format P26 PST.00 NoSet Print format 0: Number P26 PST.01 P26 PST.02 P26 PST.03 Lng-X Print format 3: Width Edited label in factory: 1~9; Available label edit number 10~29. Name Print format 1: Name Sort Print format 2: Using sort P26 PST.04 Lng-Y Print format 4: Height P26 PST.05 Txt01 Print format 5: Text 1 P26 PST.06 Txt02 Print format 6: Text 2 P26 PST.07 Txt03 Print format 7: Text 3 P26 PST.08 Txt04 Print format 8: Text 4 P26 PST.09 Txt05 Print format 9: Text 5 P26 PST.10 Txt06 Print format 10: Text 6 P26 PST.11 Txt07 Print format 11: Text 7 P26 PST.12 Txt08 Print format 12: Text 8 P26 PST.13 Txt09 Print format 13: Text 9 P26 PST.14 Txt10 Print format 14: Text 10 P26 PST.15 Txt11 Print format 15: Text 11 P26 PST.16 Txt12 Print format 16: Text 12 P26 PST.17 Txt13 Print format 17: Text 13 P26 PST.18 Txt14 Print format 18: Text 14 41 Menus Menu Prompt Instructions Remarks P26 PST.19 Txt15 Print format 19: Text 15 P26 PST.20 Txt16 Print format 20: Text 16 P26 PST.21 FontM Print format 21: Font mode P26 PST.22 State Suggest new font mode after V2.03 but still support old font LAS Print format 22: Print Item P26 LAS.00 NoSet Print item 0: Item number Available print item edit number 0~99. P26 LAS.01 Flag1 Print item 1: Symbol 1 P26 LAS.02 Flag2 Print item 2: Symbol 2 P26 LAS.03 Flag3 Print item 3: Symbol 3 P26 LAS.04 Print Print item 4: Print state P26 LAS.05 Angel Print item 5: Print angle P26 LAS.06 Grid Print item 6: Type of snap to grid P26 LAS.07 CFont Print item 7: Print font P26 LAS.08 S-X Print item 8: Start position X P26 LAS.09 S-Y Print item 9: Start position Y P26 LAS.10 L-X Print item 10: Area length X P26 LAS.11 L-Y Print item 11: Area length Y P27 DTSet Sales Salesman Available salesman edit number 10~99 P27 SAL.00 NoSet Salesman 0: Number P27 SAL.01 Name Salesman 1: Salesman name P27 SAL.02 P3 Pass DTAss P31 Salesman 1: Salesman password Data assistant DTAss Sk-PLU PLU Prog skip step setting P31 PLU.00 NoSet PLU 0: Number P31 PLU.01 ICode PLU 1: Item Code P31 PLU.02 Index PLU 2: Index for exterior barcode P31 PLU.03 Unit P31 PLU.04 Price PLU 4: U.Price P31 PLU.05 Cost PLU 5: Cost P31 PLU.06 Tare PLU 6: Tare P31 PLU.07 PST-1 PLU 7: Print format number of 1st bill P31 PLU.08 BarT1 PLU 8: Barcode number of 1st bill P31 PLU.09 BarF1 PLU 9: Barcode flag of bill 1st bill P31 PLU.10 PST-2 PLU 10: Print format number of 2nd bill P31 PLU.11 BarT2 PLU 11: Barcode number of 2nd bill PLU 3: Unit nd P31 PLU.12 BarF2 PLU 12: Barcode flag of 2 bill P31 PLU.13 P31 PLU.14 Name PLU 14: Goods name P31 PLU.15 Des-1 PLU 15: Goods postil 1 P31 PLU.16 Des-2 PLU 16: Goods postil2 P31 PLU.17 Des-3 PLU 17: Goods postil3 P31 PLU.18 Des-4 PLU 18: Goods postil4 P31 PLU.19 Des-5 PLU 19: Goods postil5 P31 PLU.20 Des-6 PLU 20: Goods postil6 P31 PLU.21 Des-7 PLU 21: Goods postil7 P31 PLU.22 PS-SD Choice 0: Prog means to be programme, Choice 1: Skip means skiped in programme Class PLU 13: class that it belongs to PLU 22: Sale date print Attached: PLU.27: Sale date data 42 Menus Menu Prompt Instructions P31 PLU.23 PS-ST P31 PLU.24 PS-PD P31 PLU.25 PS-PT P31 PLU.26 PS-UD P31 PLU.32 DF-U P31 PLU.33 DF-D P31 PLU.36 DA-S0 Remarks State PLU 23: Sale time print Attached: PLU.28: Sale time data PLU 24: Packing date print Attached: PLU.29: Packing date print PLU 25: Packing time print Attached: PLU.30: Packing time data PLU 26: Shelf date print Attached: PLU.31: Shelf date data PLU 32: Manual discount upperlimit Attached: PLU.34 PLU 33: Manual discount lower limit Attached: PLU.35 PLU 36: Customize 0 of auto discount Attached: PLU.37-PLU.55 P32 DTAss SkFPLU PLU F-Prog skip step setting P33 DTAss The same as P31 P33 Delete Delete data of the scale Validate code is needed to enter: 9958. DEL.01 Dept Delete1: Dept. When entering to delete, system would request P33 DEL.02 Class Delete2: Class to input 2 numbers which mean the start P33 DEL.03 PLU Delete3: PLU number and the end number of the data to P33 DEL.04 Unit delete. If the end number is 0, only data of the P33 DEL.05 BCode Delete5: Barcode start number would be deleted. If the number is P33 DEL.06 PSets Delete6: Print format not 0 and it’s less than start number, no data P33 DEL.07 would be deleted. P4 Sales Delete7: Salesman Commu P41 Delete4: Unit Communication setting Commu U-Disk Load and save of data in USB flash disk P42 Commu Ethnet Not real-time Download from Ethernet P43 Commu RS-232 RS232communication P44 Commu USlave USB slave communication P44 Commu P5 PTR HWAss P51 Hardware assistant setting Admin password is required to enter administrator’s password: 200806 HWAss Set-PW Hardware: setting password P511 HWAss Set-PW Admin : Admin password P512 HWAss Set-PW Sale : Sale password P513 HWAss Set-PW Prog : Prog password P514 HWAss Set-PW Account : Account password P515 HWAss Set-PW Drawer : Drawer password P52 Not Open Ethernet printer communication Input same passwords 2 times to complete amendment of password. HWAss TMS-DFHardware: Recover factory default P521 HWAss TMS-DFFac-Set P522 HWAss TMS-DF Base-DT default) P523 HWAss TMS-DFEraseDT P524 HWAss TMS-DF : Scale parameter(P1x) : Default working data(P2x Fac-All : All working data(P2x) : All parameters and The interface that requires to input validate code would be shown before default setting. Input 9958 to finish setting. data(P2x) 43 5.3 The Edit of All Parts in TMSet 5.3.1 Time Programme Example 5-1 Time Programme Operations Keys 『Sale Idle』 Enter programme 【Prog】 Enter TMSet 【1】 Enter time 【1】 programme Input current time by number key Tare 0.000 P1 P11 2008 Year Display Change/ U.Price 0.00 Weight/ Single/ Count Total 0.000 0.00 TMSet TMSet Time 05 19 20 21 51 W-1 Month Day Hour Minute Second Week …… Save time 【Amend】 P11 Return to sale 【Sale】 0.000 TMSet 0.000 Time 0.00 0.00 Remarks 〖Sale〗,〖Sum〗on. 〖Prog〗 on. W-0 means Sunday, W-1 means Monday, and the like. Cursor indicates current editing object. And using 【←】 【→】 could move the position of cursor. Save to the scale. 〖Sale〗, 〖Sum〗on. 5.3.2 Programme of Spec Parameters Example 5-2 Programme of Spec parameters Operations 『Sale Idle』 Enter programme Enter TMSet Enter Spec Change to 2 Enter Spec002 Change to 77 Choose steps directly Input step 40 Confirm step Change to 99 Save and exit Return to sale Display Keys Remarks Weight/ Change/ Single/ Tare Count U.Price Total 0.000 0.000 0.00 0.00 〖Sale〗, 〖Sum〗on. P1 TMSet 【Prog】 〖Prog〗on. P11 TMSet Time 【1】 P12 SP.000 1 1 【2】 Spec No. Origin Set Current Set P12 SP.000 1 2 【2】 Using【】 【】 can only 0 0 get to amend items in Spec 【】【】 P12 SP.002 amend level 0. P12 SP.002 0 77 【7】【7】 Input 1-1 0 【×】 The input number of step must be in Spec amend Input 1-1 40 【4】【0】 level 0 or 1. If not, the step cannot be reached. 0 0 【Confirm】 P12 SP.040 P12 SP.040 0 99 【9】【9】 P12 TMSet Spec 【Amend】 0.000 0.000 0.00 0.00 【Sale】 〖Sale〗, 〖Sum〗on. N o t e 1 The way it programmes is the same as the way in Fast-Prog of Spec Parameters in page 19, except the way it enters programme page. N o t e 2 Please refer to Definitions of Spec data parameters in page 73 for definitions of all items of Spec 44 data parameters. 5.3.3 Programme of Text Parameters Example 5-3 Programme of Text Parameters Operations Keys 『Sale Idle』 Enter programme Enter TMSet 【Prog】 【1】 Enter String 【3】 Switch to device name Switch to store name Enter editing 【→】 【←】 【Confirm】 Clear original text 【End】 Switch to EN-2 Save editing text Return to sale mode 【Switch】 【Amend】 【Sale】 Tare 0.000 P1 P11 P13 Display Remarks Weight/ Change/ Single/ Count U.Price Total 0.000 0.00 0.00 〖Sale〗, 〖Sum〗on. TMSet 〖Prog〗on. TMSet Time ST.000 ShopN Push-OK ST.000 is store name. String No. String Info P13 ST.001 P13 ST.000 EN-1 0 EN-1 ScaleN Push-OK ST.001 is device name. ShopN Push-OK In view of have original text, Suggesting users press 【 End 】 before editing to clear former text.. If modify on original literal, use【】 【】to move cursor to target position 0 EN-2 0 P13 PLU.14 0.000 0.000 Name 0.00 0 OK-Edit Save to the scale. 0.00 〖Sale〗, 〖Sum〗 on. N o t e 1 Please refer to 7.3 Definitions of String data paremeters for definitions of each text parameter. 5.3.4 Programme of PLU Shortcut Keys Example 5-4 Programme of PLU Shortcut Keys Display Remarks Weight/ Change/ Single/ Tare Count U.Price Total 0.000 0.000 0.00 0.00 〖Sale〗, 〖Sum〗 on. 『Sale Idle』 Enter programme P1 TMSet 【Prog】 〖Prog〗on. Enter TMSet P11 TMSet Time 【1】 Enter PLU shortcut key P14 scPLU -----------【4】 Set SC1 P14 scPLU 0-01 0 【SC1】 Input PLU number P14 scPLU 0-01 10 【1】【0】 Confirm input ------------ Save to temporary buffer. 【Confirm】 P14 scPLU Set SC2 P14 scPLU 0-02 0 【SC2】 Input PLU number P14 scPLU 0-02 11 【1】【1】 Confirm input ------------ Save to temporary buffer. 【Confirm】 P14 scPLU Set Shift+SC1 1-01 0 【Shift】 【SC1】P14 scPLU Input PLU number 【1】【0】【0】 P14 scPLU 1-01 100 Operations Keys 45 【Confirm】 Confirm input P14 scPLU 【Amend】 P14 TMSet 0.000 0.000 【Sale】 Save editing text Return to sale mode ------ scPLU 0.00 Save to temporary buffer. The last confirm can be ------skipped. Press 【Amend】 directly. Save to the scale. 0.00 〖Sale〗, 〖Sum〗on. N o t e 1 The way it programmes is the same as the way of Example 3-2 and Example 3-3 in page 18, except the way it enters programme interface. 5.3.5 Programme of Fuction Shortcut Keys Example 5-5 Programme of Fuction Shortcut Keys Operations 『Sale Idle』 Enter programme Enter TMSet Enter Fuction shortcut Set SC1 Input Fuction number Save editing text Return to sale mode Display Keys Remarks Weight/ Change/ Single/ Tare Count U.Price Total 0.000 0.000 0.00 0.00 〖Sale〗, 〖Sum〗 on. P1 TMSet 【Prog】 〖Prog〗on. P11 TMSet Time 【1】 P15 scFuc -----------【5】 P15 scFuc 0-01 0 【SC1】 P15 scFuc 1 76 Fuction “Custom Info 1”=76 【7】【6】 scFuc Save to the scale. 【Amend】 P15 TMSet 0.000 0.000 0.00 0.00 〖Sale〗, 〖Sum〗on. 【Sale】 N o t e 1 Please refer to 7.4 Definitions of Shortcut Function Key for details 5.4 The Edit of All Parts in DTSet 5.4.1 Department Programme The department (Dept. for short) is the largest category in sales statistics. And it’s marked with number from 1 to 99 and the corresponding meanings are shown below: Number 1 2 8 9 10~99 Use System Dept. System Dept. System Dept. Default Dept. User Dept. Instructions Not edited weight Dept. Not edited count Dept. Error Dept. Default Dept. for Class editing Dept. that users can edit Example 5-6 Department Programme Operations Keys 『Sale Idle』 Enter programme Enter DTSet 【Prog】 【2】 Enter Dept. programme 【1】 Enter number 10 Next 【1】【0】 【→】 Tare 0.000 P1 P21 P21 P21 P21 Display Remarks Weight/ Change/ Single/ Count U.Price Total 0.000 0.00 0.00 〖Sale〗, 〖Sum〗 on. TMSet 〖Prog〗 on. DTSet Dept DPT.00 NoSet 0 Step No. Step Info Object DPT.00 NoSet 10 DPT.01 Name OK-Edit 46 Edit department name Save editing data Return to sale mode 【Amend】 P21 DPT.00 0.000 0.000 【Sale】 NoSet 0.00 0 0.00 Department names would usually not be printed. And they are always used for management in PC. So editing their names is of little meaning. Here we skip it off. Continue to edit other 〖Sale〗, 〖Sum〗 on. 5.4.2 Class Programme Class is the second largest category in sales statistics. And it is marked with number from 1 to 99 and the corresponding meanings are shown below: Number 1 2 8 9 10~99 Dept. 1 2 8 9 Use System Class System Class System Class Default Class User Class Instructions Not edited weight Class Not edited count Class Error Class Default Class for PLU editing Class that users can edit Example 5-7 Class Programme Operations Keys Tare 『Sale Idle』 Enter programme Enter DTSet 【Prog】 【2】 Enter class programme 【2】 Input class number 10 Next 【1】【0】 【→】 P22 P22 【→】 P22 【1】【0】 P22 0.000 P1 P21 P22 Edit class name Next Input department number 10 Save editing class Return to sale mode Display Remarks Weight/ Change/ Single/ Count U.Price Total 0.000 0.00 0.00 〖Sale〗, 〖Sum〗 on. TMSet 〖Prog〗 on. DTSet Dept CLS.00 NoSet 0 Step No. Step Info Object CLS.00 NoSet 10 CLS.01 Name OK-Edit Class names would usually not be printed. And they are always used for management in PC. So editing their names is of little meaning. Here we skip it off. Department that the class CLS.02 Dept 0 belongs to. And the department must exist. CLS.02 Dept 10 【Amend】 P22 CLS.00 0.000 0.000 【Sale】 NoSet 0.00 0 0.00 Continue to edit other classes. 〖Sale〗, 〖Sum〗 on. 5.4.3 PLU Programme Price-LookUp is information cell for goods sale. Serial number of PLU, as the only sign of scale store PLU, is defined by user to correspond to actual goods. Remark number, as the number defined by users or the serial number of actual goods, is often printed as barcode. All the serial numbers which can be edited by users are from 47 10 to 9999999. And special serial numbers are corresponding to the meanings shown below: Internal Number 1 2 3 10~5999 Number Class Use Instructions 9999999 9999998 9999997 1~9999996 1 2 3 System PLU System PLU System PLU User PLU Not edited weight PLU Not edited count PLU Service charge PLU PLU for users to edit Example 5-8 PLU Programme Display Operations Keys Weight/ Change/ Tare Count U.Price 0.000 0.000 0.00 『Sale Idle』 Enter Prog P1 TMSet 【Prog】 Enter DTSet P21 DTSet Dept 【2】 P23 PLU.00 Not Set PLU Prog 【3】 Step No. Step Info PLU Number 【1】【0】 P23 PLU.00 Not Set Go to Next P23 PLU.01 ICode 【】 Input Item-Code 90001 P23 PLU.01 ICode Go to Next 【】 P23 PLU.03 Unit Set as weight PLU 【1】 P23 PLU.03 Unit Go to Next 【】 P23 PLU.04 Price Set U.Price 【3】 【0】 【00】P23 PLU.04 Price Go to Next Set cost Go to Next 【】 P23 PLU.05 Cost 【2】 【4】 【00】P23 PLU.05 Cost 【】 P23 PLU.06 Tare Single/ Total 0.00 Remarks 〖Sale〗,〖Sum〗on. 〖Prog〗 on. 0 〖Prog〗on. Object 10 Number are between 1~9999999 0 ICode is Item-Code, which is usually printed as part of letters on barcode print. If the number of barcodes is 90001 default 2/5 or other custom numbers, ICode are printed as a part of barcodes. Please see details in chapter Barcode. 0 【0】,【1】: default weight unit; 【2】: default count unit; 【3】: kg weight unit; 【4】: g weight unit; 【5】: ton weight unit; 【6】: lb weight unit; 1 【7】: 500g weight unit; 【8】: 100g weight unit; Please see details in unit chapter. Default weight unit mean the unit used for display. And it is suggested for weight PLU. 0.00 Preset U.Price in sale. Don't have to 30.00 input it. Users can temporarily input it in sale. 0.00 The cost is used to calculate the profits. 24.00 Don’t have to input it. 0.000 48 Set Tare Go to Next Set name Clear Original Text P ork Input number 2 Save edited text Go to next 【5】 P23 PLU.06 P23 PLU.14 【】 0 【Confirm】 En-1 【End】 Tare Name In consideration of there was a text, we suggest users press 【End】 before editing. If editing in the original text, users could use【】 【】 to move the position of cursor. EN-1 0 【Shift】 【p/P】EN-1 【o/O】【r/R】 EN-1 【k/K】 EN-1 【-】 1 P 4 rk 5 k- 6 -2 【2】 En-1 【Amend】 P23 PLU.14 【】 P23 PLU.26 When transferring PLU, it’s preset tare. Don’t have to input it. OK-Edit Input the names of goods. 0.005 Name PS-UD This 【Amend】 is to save text edit in buffers instead of PLU. Please pay OK-Edit attention: If users need save it in PLU, users need to press【Amend】 again as the step below. 0 If to print the shelf life date Print shelf date 【1】 P23 PLU.26 PS-UD 1 Go to next 【】 P23 PLU.31 PC-UD 0 Input shelf days 【】 P23 PLU.31 PC-UD 3 Not Set 0 0.00 0.00 …… P23 Save edited 【Amend】 P23 PLU.00 PLU Return to sale 【Sale】 0.000 0.000 0: Don't print PLU 31 invalid 1: Print. Continiune to set shelf days in PLU.31 Shelf days. 0 means intraday valid, followed like this. If all cargo for one scale use same shelf days, use Spec105 & Spec106 If other steps are still to be edited, users can use 【】【】 to switch steps. PLU10 is saved. 〖Sale〗,〖Sum〗 on N o t e 1 Except the parts which have been instructed, meaning of the other words are listed List of Programme Interface in page 46 N o t e 2 The way it programmes is the same as the way Fast-Prog of Example 3-1 in page 16, except the way it enters programme page. N o t e 3 xx is not continuous when users press【】and【】to select the programme content. There are two reasons. First reason is that the content in this part is meaningless. For example, tare is not present in count PLU programme. The second reason is that the content in that part is seldom used and has been set as non-programme content (Skip) in P31 and P32. Users could change that setting for personel usage and please refer to corresponding chapters for details. 5.4.4 Unit Programme Unit is the basis of sale price. The scale has shielded parts of functions in consideration that edit of units may 49 cause unnecessary trouble. The 8 units edited when when the scale is released from factory are shown as below: Number 1 2 3 4 5 6 7 8 9~19 20~99 Instructions Default weight unit Default count unit Kg unit g unit ton unit lb unit 500g unit 100g unit System reserved unit Unit for user to add N o t e 1 Default weight unit is the measure unit of the scale. Example 5-9 Unit Programme Operations 『Sale Idle』 Enter programme Enter DTSet Enter unit programme Enter number 30 Next Set unit name Clear orginal text Save editting text Save editing unit Return to sale mode Keys 【Prog】 【2】 【4】 Tare 0.000 P1 P21 P24 【3】【0】 【→】 【Confirm】 【End】 【Amend】 【Amend】 P24 P24 En-1 En-1 P24 P24 【Slae】 0.000 Display Remarks Weight/ Change/ Single/ Count U.Price Total 0.000 0.00 0.00 〖Sale〗, 〖Sum〗 on. TMSet 〖Prog〗 on. DTSet Dept UNT.00 NoSet 0 Step No. Step Info Object UNT.00 NoSet 30 UNT.01 Name OK-Edit 0 Unit name printed as unitage 0 UNT.01 Name OK-Edit Save unit to buffer UNT.00 NoSet 0 Go on edit other unit 0.000 0.00 0.00 〖Sale〗, 〖Sum〗 on. 5.4.5 Barcode Programme Barcodes have different meanings in various applications and coding systems. Some barcodes are already edited when the scale is released from factory. Users could choose some barcodes from them to use or edit the barcode for themselves. Number 1~9 Use Factory Default 10~99 User’s barcode Instructions Already edited when the scale is released from factory User cannot edit them. Barcode that can be edited by users Example 5-10 Barcode Programme Operations Keys 『Sale Idle』 Enter programme 【Prog】 Display Remarks Weight/ Change/ Single/ Tare Count U.Price Total 0.000 0.000 0.00 0.00 〖Sale〗, 〖Sum〗 on. P1 TMSet 〖Prog〗 on. 50 Enter DTSet 【2】 Enter barcode 【5】 Enter number 10 Next 【1】【0】 【→】 P21 DTSet Dept BAR.00 NoSet 0 P25 Step No. Step Info Object P25 BAR.00 NoSet 10 P25 BAR.01 Name OK-Edit Edit barcode names Next 【→】 P25 BAR.02 Type 0 Next 【→】 P25 BAR.03 Check 0 Next Next Next 【→】 【→】 【→】 P25 BAR.04 NCon1 0 P25 BAR.05 Ncon2 0 P25 BAR.06 Des OK-Edit Edit the descriptions of barcodes Save editing barcode Return to sale mode P25 【Amend】 P25 BAR.00 NoSet 0.000 0.000 0.00 【Sale】 0 0.00 Barcode names would usually not be printed. And they are always used for management in PC. So editing their names is of little meaning. Here we skip it off. See Table 5-1 List of Barcode Types. See Table 5-2 Check Digit of Barcode. It could be used as fixed number in barcode data. Barcode descriptions should be in exact appointed format and edit a text with the length of 24. Otherwise the format would be invalid when it’s printed. Please refer to the content of Table 5-3 Descriptions of Barcode Data Items and Table 5-4 Factory Default Barcode. Continue to edit other barcodes. 〖Sale〗, 〖Sum〗 on. Table 5-1 List of Barcode Types Barcode formats 0 1 2 3 4 5 6 7 Instruction Default EAN13 EAN8 UPC A UPC E EAN-128 Code-128C ITF-25 Valid number digit (suggest) 12 7 11 6 Even or Odd with Checksum Even or Odd with Checksum Even or Odd with Checksum N o t e 1 When select default, it will auto select the most reasonable barcode format according to valid number digit N o t e 2 When print EAN-128, Code-128C or ITF-25, if length of number is odd number, it will auto add one checksum at the end. The arithmetic is same as EAN/UPC checksum 51 Table 5-2 Check Digit of Barcode Check ways 0 1 2 3 All checks End Check Middle Check Not check N o t e 1 Check digit of barcode for barcode formats is just an advice for the scale. The scale would process the check based on the selected barcode format. For example, EAN13 is verified by End Check no matter which kind of check is selected. Table 5-3 Descriptions of Barcode Data Items Items Restrictions A B C D E F G H I J K L M N L P Q R S Instructions Not print Spec Flag Constant Num 1 Constant Num 2 PLU Number PLU Item-Code PLU Index PLU Flag PLU real U.Price PLU count/weight PLU T.Price Sale T.Price Sale T.Count Sale T.Weight Add-up Times Sales man number Sale date: year Sale date: month Sale date: date Print length 0~9 Data Source A~Z Display Length 0~9 Data Shift 0~9 Move to right 0~9 digits 0~3 0: not print 1: truncation print 2: fill in with character 0 3: fill in with character 9 Overflow management Table 5-4 Factory Default Barcode Number Name Descriptions 1 B-Item 1 B201E500K500A000A000A000 2 B-Item 2 B201F500K500A000A000A000 3 B-Item 3 F700K500A000A000A000A000 Use Instructions 2 digits Spec Flag, Item 5 digits PLU Number, barcode 5 digits PLU T.Price. 2 digits Spec Flag, Item 5 digits PLU Item-Code, barcode 5 digits PLU T.Price. Item 7 digits PLU Item-Code, barcode 5 digits PLU T.Price. 52 4 B-Item 4 B201E400K600A000A000A000 Item barcode 5 B-Item 5 B201F400K600A000A000A000 Item barcode 6 B-Item 6 F600K600A000A000A000A000 7 B-Sum 1 B701L500A000A000A000A000 8 B-Sum 2 B601L600A000A000A000A000 9 B-Sum 3 B501L700A000A000A000A000 Item barcode Total barcode Total barcode Total barcode 2 digits Spec Flag, 4 digits PLU Number, 6 digits PLU T.Price. 2 digits Spec Flag, 4 digits PLU Item-Code, 6 digits PLU T.Price. 6 digits PLU Item-Code, 6 digits PLU T.Price. 7 digits Spec Flag, 5 digits Sale T.Price. 6 digits Spec Flag, 6 digits Sale T.Price. 5 digits Spec Flag, 7 digits Sale T.Price. 5.4.6 Print Formats Programme Number 1~9 10~39 Use Factory default User’s print format Instructions Already edited when the scale is released from factory Print format can be edited by users Different print formats are needed in various applications. Some print types are already edited when the scale is released from factory. Users could choose some formats from them or edit the format for themselves. It’s very hard to edit print format on the scale. Suggest users do not edit print format on the scale. This chapter would not offer any examples about print formats edit. Users should use the software on PC to edit print formats or write down demands and send them to us. We will edit the print format you need. Table 5-5 Factory Default Print Formats No. 1 2 3 4 5 6 7 8 9 Format Item Label Item Label Item Label Total Label Total Label Total Label Receipt Receipt Receipt Gap Paper 58mm*40mm 40mm*30mm 58mm*30mm 58mm*40mm 40mm*30mm 58mm*30mm Plain Paper 58mm 40mm 58mm 58mm 40mm 58mm 58mm 40mm 48mm N o t e 1 If users use gap paper in size of 58mm*30mm, set the value of Spec000 to 1, Spec001 to 4. N o t e 2 If users use gap paper in size of 40mm*30mm, set the value of Spec000 to 2, Spec005 to 5. N o t e 3 If users use gap paper in size of 58mm*30mm, set the value of Spec000 to 3, Spec005 to 6. N o t e 4 If users use plain paper in width of 58mm, set the value of Spec000 and Spec005 to 7 N o t e 5 If users use plain paper in width of 40mm, set the value of Spec000 and Spec005 to 8. N o t e 6 If users use plain paper in width of 48mm, set the value of Spec000 and Spec005 to 9. Table 5-6 Factory Default Print Formats for cash register scale No. 1 Format Receipt Gap Paper 48mm Plain Paper Print PLU number 53 2 3 4 8 9 Receipt Receipt Receipt List List 48mm 48mm 48mm 48mm 48mm Print number New Line mode with Name Large Font Mode Cookroom Use List Cookroom Use List, Large Font Mode N o t e 1 User can use format 8 or 9, when remote printer is used as a cookroom printer. If user really need to edit print format on the scale, please refer to 5.2.3 List of Programme Interface of P26 print format, following table are example to user refer: Table 5-7 Print format: Print-item instruction Print Item Name Sort Length Number Range Instruction Item No. Number Sign 1 Flag1 Number 1 0~99 Unique number with order Code 1 Sign 2 Flag2 Code 1 Sign 3 Flag3 Code 1 Refer to later table 0: Not Print 1: Print 2: By-weight PLU print 3: By-count PLU print 4: Temporary PLU print 5: Tared PLU print 6: Free PLU print Print State Print Code 1 0~255 7: Print with sale date 8: Print with packing date 9: Print with shelf date 10: Not 1pcs PLU print 11: Item service charge print 12: Service charge print 13: Taxed PLU print Other: not defined Angle Angle Code 1 0~3 Clockwise rotation: Angle*90 Snap to grid Grid Code 1 0~9 1~9: 9 position, 0: default Font CFont Code 1 X Position S-X Y Positon S-Y Width L-X Height L-Y Coordinate Coordinate 3~5 Version before V2.03 0~9 Version after V2.03 and V2.03 2 0 ~ 65535 2 0 ~ 65535 2 0 ~ 65535 2 0 ~ 65535 Start coordinate for print area Height and width for print area Table 5-8 Print format: Print-item code Flag1 Code Content 0 Barcode 1 Item Info Flag2 Code Flag3 Content 0 Readable 1 Not Readable Code Content Flag3 blank means no effect. Followed are the same 0 X 0 Name 1 1 1 Amount 2 2 2 Tare If Flag2=3, it means print the information for the third 3 3 3 First Unit Price 4 4 4 Payable Unit Price ‘X’ in Flag2 means print all cargo in turn. accumulate cargo’s 54 2 Sale Info 5 5 5 Price 6 6 6 PLU Number 7 7 7 Class Number 8 8 8 Dept. Number 9 9 9 Index 10 10 10 Item-Code 11 11 11 Sale Date 12 12 12 Sale Time 13 13 13 Package Date 14 14 14 Package Time 15 15 15 Shelf Date … … 16 Text 1 18 18 17 Text 2 19 19 18 Text 3 20 20 19 Text 4 21 21 20 Text 5 22 22 21 Text 6 23 23 22 Text 7 24 24 23 Gross 25 25 24 Measure Unit 26 26 25 Price Unit 27 27 26 Price without Tax 28 28 27 Tax 29 29 28 Item Service Fee 30 30 29 Tax Rate 31 31 30 PLU No and Name 0 Store Name 1 Device Name 2 Device Number 3 Print Date 4 Print Time 5 Add-up Times 6 Total Count 7 Total Weight 8 Total Price 9 Payment 10 Change 11 Rounding Money 12 Unit of Weight 13 Unit of Weight Price 14 Unit of Count 15 Unit of Count Price 16 Unit of Money 17 Device Postil 1 18 Device Postil 2 19 Device Postil 3 20 Device Postil 4 21 Device Postil 5 55 22 Device Postil 6 23 Device Postil 7 24 Device Postil 8 25 FID 0~8 Least Digital 26 SID 0~8 Least Digital 27 Net Price 28 Gross Price 29 Money of Discount and Rounding 30 3 4 5 Salesman No. 31 Salesman Name 32 Total Price without Tax 33 Total Tax 34 Waiter Number 35 Waiter Name 36 Text of Item Service Fee 37 Text of Service Fee 38 Industry Mark 39 Reserved 4 40 Reserved 5 41 Reserved 6 42 Reserved 7 43 Reserved 8 44 Service Fee 45 Tax of Service Fee 46 Service Fee without Tax 47 Buffer Number Const Text 0~15 Outline Border Partition 0~15 1~24 1~24 0 Area Flag 1 Page Print 2 Line Print Flag2 is text series number Flag2 is outline boarder thickness 0 ~32 0mm~32mm 5.4.7 Salesman Programme Example 5-11 Salesman Programme Operations Keys 『Sale Idle』 Enter programme 【Prog】 Enter DTSet 【2】 Enter salesman programme 【7】 Enter salesman 10 【1】【0】 Next 【→】 Edit salesman name Tare 0.000 P1 P21 P27 P27 P27 Display Remarks Weight/ Change/ Single/ Count U.Price Total 0.000 0.00 0.00 〖Sale〗, 〖Sum〗 on. TMSet 〖Prog〗 on. Step No. Step Info Object DTSet Dept SAL.00 NoSet 0 SAL.00 NoSet 10 SAL.01 Name OK-Edit Process is omitted. 56 Next P27 SAL.02 【→】 Edit salesman password Save editing salesman 【Amend】 P27 SAL.00 Return to sale mode 【Sale】 0.000 0.000 Pass 0 NoSet 0.00 0 0.00 Continue to edit other salesmen. 〖Sale〗, 〖Sum〗 on. N o t e 1 Number 1~99 is the content for users to edit. 5.5 Assistant Data Programme 5.5.1 Steps Select of PLU Programme Example 5-12 Steps Select of PLU Programme Operations 『Sale Idle』 Enter programme Enter DTAss Enter step selection of PLU prog Select step: ICode Select step: Index Barcode Display Keys Weight/ Change/ Tare Count U.Price 0.000 0.000 0.00 【Prog】 P1 TMSet P31 DTSet Sk-PLU 【3】 P31 PLU.00 NoSet 【1】 PLU Step Step Info P31 PLU.01 ICode 【→】 【→】 P31 Enable step: Index Barcode 【↓】 P31 Select step: Unit P31 【→】 Select step: U.Price P31 【→】 Select step: Cost P31 【→】 Disable step: Cost P31 【↓】 Save steps selection 【Amend】 P31 Return to sale mode 【Sale】 0.000 PLU.02 Index PLU.02 Index PLU.03 Unit PLU.04 Price PLU.05 Cost PLU.05 Cost DTSet Sk-PLU 0.000 0.00 Remarks Single/ Total 0.00 〖Sale〗, 〖Sum〗 on. 〖Prog〗 on. Prog 0 Prog or Skip Prog 0 Skip Prog Prog Prog Prog Skip 0 0.00 Default index number is not activated. 0 Amend to activation. 0 0 0 Default cost is activated. 1 Amend to not activated. 1 〖Sale〗, 〖Sum〗 on. N o t e 1 The steps above activate steps Index Barcode and shield steps Cost.And then there is a step to input index in the programme of P23, but no step to input cost. Select Prog or Skip by pressing【0】\【1】 or 【↑】【 \ ↓】. If Prog is selected, the step is in the programme. If Skip is selected, the step is skiped and not in programme. N o t e 2 Amended content would be in effect only in PLU programme and not effective in fast-prog. 5.5.2 Steps Select of PLU Fast Programme Example 5-13 Steps Select of PLU Fast Programme Operations 『Sale Idle』 Enter programme Enter DTAss Enter step selection of Display Keys Remarks Weight/ Change/ Single/ Tare Count U.Price Total 0.000 0.000 0.00 0.00 〖Sale〗, 〖Sum〗 on. 【Prog】 P1 TMSet 〖Prog〗 on. P31 DTSet Sk-PLU 【3】 P32 PLU.00 NoSet Prog 0 【2】 57 PLU fast prog Select step: ICode 【→】 P32 PLU Step PLU.01 Select step: Index 【→】 P32 PLU.02 Enable step: Index Select step: Unit Select step: U.Price Select step: Cost Disable step: Cost Save steps selection Return to sale mode P32 【↓】 P32 【→】 P32 【→】 P32 【→】 P32 【↓】 【Amend】 P32 【Sale】 0.000 Step Prog or Info Skip ICode Prog 0 Index PLU.02 Index PLU.03 Unit PLU.04 Price PLU.05 Cost PLU.05 Cost DTSet Sk-PLU 0.000 0.00 Skip Prog Prog Prog Prog Skip 0 0.00 Default index number is not activated. 0 Amend to activation. 0 0 0 Default cost is activated. 1 Amend to not activated. 1 〖Sale〗, 〖Sum〗 on. N o t e 1 The processes are the same as Example 5-12 only if amended contents only work in PLU fast-prog instead of PLU programme. 5.5.3 Delete Sale Data When entering the interfaces of delete, users would be requested to receive validate code. Validate code is 9958. Confirm and enter delete process. Example 5-14 Delete PLU20~30 Display Operations Keys Remarks Weight/ Change/ Single/ Tare Count U.Price Total 0.000 0.000 0.00 0.00 〖Sale〗, 〖Sum〗 on. 『Sale Idle』 Enter programme P1 TMSet 【Prog】 〖Prog〗 on. Enter DTAss P31 DTSet Sk-PLU 【3】 Enter interface of delete Input Code 0 Request input validate code . 【3】 【9】 【9】 【5】 Input validate code Input Code 9958 【8】 【1】: Dept., 【2】: Class, 【3】: PLU, Confirm validate code 【Confirm】 P331 DTSet Delete Dept 【4】: Unit, 【5】: Barcode, 【6】: Print Format 【7】: Salesman. Select to delete PLU Input 2-1 0 【3】 【2】【0】 Input start number Input 2–2 0 【Confirm】 【3】【0】 Input end number P333 DTSet Delete PLU 【Confirm】 Return to sale mode 0.00 0.00 〖Sale〗, 〖Sum〗 on. 【Sale】 0.000 0.000 N o t e 1 Once confirming to delete object, users shall be requested to input 2 numbers. And system would delete data objects in the range between the two numbers. If the 2nd number is 0, the object appointed by 1st number is deleted. If 2nd number is less than 1st number, no object is deleted. 58 5.6 Communication and Data Update 5.6.1 Operations of files in USB flash Disk. Data edited on PC could transfer by USB flash disk. The software would create a file in the directory of JHSCALE when exporting a file to USB flash disk. If users export auto-update file, the form of file is A_xxx.TMS. If the scale has set USB flash disk auto-update (factory default setting), after switch on, the scale would update the data when system detects the file in USB flash disk In P41, press【×】 to select auto-update file A_xxx.TMS, or input number to select numbered files from A_000.TMS to A_999.TMS (The number is file serial number ). Press【Confirm】to load file data and update the information in the scale. Or press 【Amend】 to save scale information to appointed file. Example 5-13 Load Files in USB Flash Disk Operations Keys Tare Display Weight/ Change/ Count U.Price 0.000 0.00 TMSet 『Sale Idle』 Enter programme 【Prog】 0.000 P1 Enter Commu 【4】 P41 Commu U-Disk Enter operation of USB flash disk 【1】 P41 Commu U-Disk Single/ Total 0.00 Remarks 〖Sale〗, 〖Sum〗 on. 〖Prog〗 on. Make sure USB flash disk exists. 000 Input number here to load numbered file. Appoint auto-update P41 Commu U-Disk XXX Please make sure selected 【×】 file files are in the directory JHSCALE. 0 0 0 Dw-Data When operation finishes Load files 【Confirm】 Number of Number of Number Working normally, the state change Error Data Right Data of Bytes State into finish. Several seconds 0 … … Finish Exit P41 Commu U-Disk Press any key to quit. 【Confirm】 Return to sale mode 【Sale】 0.000 0.000 0.00 0.00 〖Sale〗, 〖Sum〗 on. N o t e 1 If file is loading ends normally, system would change the state into Finish. Normally, the amount of error commands should be 0. N o t e 2 If system encounters with invalid files or other serious mistakes, change the state into Error. N o t e 3 In the state of Finish or Error, press any key to exit. If users want to exit midway, press 【Cancel】. Example 5-14 Save working data to Files in USB Flash Disk Operations 『Sale Idle』 Enter programme Enter Commu Keys 【Prog】 【4】 Tare 0.000 P1 P41 Display Weight/ Change/ Count U.Price 0.000 0.00 TMSet Commu U-Disk Remarks Single/ Total 0.00 〖Sale〗, 〖Sum〗 on. 〖Prog〗 on. Make sure USB flash disk 59 exists. Enter operation of USB flash disk Appoint numbered file Save file 【1】 P41 Commu U-Disk 000 【1】【2】 P41 Commu U-Disk 012 0 0 0 Data Sort Data Number … … … Finish 0.000 0.000 0.00 0.00 【Amend】 Several seconds Exit 【Confirm】 Return to sale mode 【Sale】 Press 【 × 】 to select auto-update file. Up-Data When operation finishes normally, the state change Number of Working into finish. Saved Data State 〖Sale〗, 〖Sum〗 on. N o t e 1 Exporting data to files in USB flash disk may take a lot of time. Please wait. N o t e 2 Press any key to exit when saving is ended. If users want to exit midway, press 【Cancel】. Example 5-15 Save sale list to Files in USB Flash Disk Operations Keys Tare Display Weight/ Change/ Count U.Price 0.000 0.00 TMSet 『Sale Idle』 Enter programme 【Prog】 0.000 P1 Enter Commu 【4】 P41 Commu U-Disk 【1】 P41 Commu U-Disk 【1】【2】 P41 Commu 0 0 Data Sort Data Number … … 0.000 0.000 Enter operation of USB flash disk Appoint numbered file Save file 【PLU】 Several seconds Exit 【Confirm】 Return to sale mode 【Sale】 Remarks Single/ Total 0.00 〖Sale〗, 〖Sum〗 on. 〖Prog〗 on. Make sure USB flash disk exists. 000 Press 【 × 】 to select auto-update file. 【 PLU 】 save the 0 Up-Data un-uploaded sale list 【F-Prog】+【PLU】 save Number of Working all un-deleted sale list( PC software’s Saved Data State repeat upload) … Finish U-Disk 012 0.00 0.00 〖Sale〗, 〖Sum〗 on. N o t e 1 Exporting data to files in USB flash disk may take a lot of time. Please wait. N o t e 2 Press any key to exit when saving is ended. If users want to exit midway, press 【Cancel】. 5.6.2 Ethernet Monitor Interface Example 5-16 Enter Ethernet Monitor Interface Operations 『Sale Idle』 Keys Tare 0.000 Display Weight/ Change/ Count U.Price 0.000 0.00 Single/ Total 0.00 Remarks 〖Sale〗, 〖Sum〗 on. 60 Enter programme 【Prog】 P1 TMSet Enter Commu 【4】 P41 Commu U-Disk 0 0 0 Number of Number of Number Error Data Right Data of Bytes 0 0 0 Data Saved Data area number data Enter Ethernet monitor interface 【2】 Transfer upload and download 【×】 Exit 【Cancel】 P42 Commu Ethernet Return to sale mode 【Sale】 0.000 0.000 0.00 Dw-Data Working State Up-Data Working State 0.00 〖Prog〗 on. Make sure USB flash disk exists. Ethernet download information and Stat. information Ethernet upload information and Stat. information Press any key to quit. If want to exit in the midway, press 【Cancel】 〖Sale〗, 〖Sum〗 on. N o t e 1 This monitor interface is usually used when the scale is set to not update in real-time on Internet. 5.6.3 RS232 Communications The interface is similar to ethernet monitor interface. If want to process RS232 communication, must firstenter this interface 5.7 Hardware Assistant 5.7.1 Validate Code On the purpose of preventing any misoperation in important operation interfaces, users are requested to input validate code when entering these operation interfaces. The interface is shown below: Input Code 0 Validate code of this scale is 9958. When the scale requests to input validate code, users should first make sure whether this operation interface is the one you intend to enter and understand the meaning of this operation. Then input validate code and do operations. 5.7.2 Password Password is the code to obtain the right to operate the scale. And there are 5 passwords in all. Amend steps Types Password type Admin password P511 Admin P512 Sale P513 Prog P514 Account Sale password Program password Account password Permission Hardware Assistant (P51) Sale interface Prog interface Account interface Sale interface Original password 200806 Please keep it safe if users amend it. 0 Prog interface 0 Account interface 0 N o t e 1 That Password is 0 means no passwords needed. Users could set the password to be 0 when canceling the password. N o t e 2 Admin password is in a higher level than the other 4 passwords. Users do not need to input any 61 password to enter all interface if admin password is 0 , no matter whether the other passwords are 0. N o t e 3 If users want to protect Prog interface or Account interface, first change the admin password other than factory default, then set passwords of corresponding interfaces. N o t e 4 Spec247’s password hold function can let the device remember the entered password, then, user do not need to input the same password repeatedly Example 5-17 Process of Amending Passwords Display Operations Keys Remarks Weight/ Change/ Single/ Tare Count U.Price Total 0.000 0.000 0.00 0.00 〖Sale〗, 〖Sum〗 on. 『Sale Idle』 Enter programme P1 TMSet 【Prog】 〖Prog〗 on. Enter hardware Assistant Input Pass 0 【5】 Display dashes is the as many Input admin password …… Input Pass ------as input numbers. Confirm password P51 HwAss Set-PW 【Confirm】 Amend password P511 HwAss Set-PW Admin 【1】 【1】: admin password 【2】: sale password 【3】: program password Amend prog password Input Pass-1 【3】 【4】: account password 【 5 】 : 【 open drawer 】 password Input password Input Pass-2 ------……【Confirm】 Repeat password ……【Confirm】 P513 HwAss Set-PW Prog Return to sale mode 0.000 0.000 0.00 0.00 〖Sale〗, 〖Sum〗 on. 【Sale】 N o t e 1 Input password must match for two times so that password setting can be done. 5.7.3 Recover Factory Default Setting Example 5-18 Process of Amending Passwords Operations 『Sale Idle』 Enter programme Enter hardware Assistant Input admin password Confirm password Recovery factory default Select the type to amend Input validate code Display Keys Remarks Weight/ Change/ Single/ Tare Count U.Price Total 0.000 0.000 0.00 0.00 〖Sale〗, 〖Sum〗 on. P1 TMSet 【Prog】 〖Prog〗 on. Input Pass 0 【5】 Display dashes is the as many …… Input Pass ------as input numbers. P51 HwAss Set-PW P521 HwAss TMS-DF Fac-Set 【2】 Here are 4 recovery types: 【1】Scale parameter(P1x) Input Code 0 【2】default working data 【4】 【3】all working data(P2x) 【4】all parameters and data Input Code 9958 【9】 【9】 【5】 【8】 62 Confirm validate code Return to sale mode 【Confirm】 【Sale】 P521 HwAss TMS-DF Fac-All 0.000 0.000 0.00 0.00 〖Sale〗, 〖Sum〗 on. N o t e 1 Please pay attention to this. Execute recovery 1 or 4, and then passwords would change to factory default. N o t e 2 If user amend the Spec irrelevantly, it will make scale do not work regularly, suggest user to executeP511 N o t e 3 P524 will let the scale recover to factory default state(all user’s data will be deleted) 63 6 Account Operations 6.1 List of Account Interfaces Entering to Account interface, the scale would enter a calculate process, which first calculate sale records. Then enter A1 select interface. Table 6-1 List of Account Interfaces Menus A1 Menu Prompt Total Instructions Total Daily Total daily report A12 Total Monly Total monthly report A13 Total Qualy Total quarterly report A14 Total Manly Total manual report A21 Dept Daily Department daily report A22 Dept Monly Department monthly report A23 Dept Qualy Department quarterly report A24 Dept Manly Department manual report Dept A3 Department report Class Class report A31 Class Daily Class daily report A32 Class Monly Class monthly report A33 Class Qualy Class quarterly report A34 Class Manly Class manual report PLU PLU report A4 A41 PLU Daily PLU daily report A42 PLU Monly PLU monthly report A43 PLU Qualy PLU quarterly report A44 PLU Manly PLU manual report Clear Clear report A5 A51 Clear A52 Clear A53 Clear A54 A6 Manly Clear current manual report information All Clear all reports and records information Stock Clear stock report information Clear SID Stock Clear SID information, reset to 0 Stock report A61 Stock Print A62 Stock Audit Stock update A7 List A71 A8 Stock print Sale list report List Print Sales A81 State Total report A11 A2 Remarks Sale list print Salesman report Sales Daily Salesman daily report A82 Sales Monly Salesman monthly report A83 Sales Qualy Salesman quarterly report A84 Sales Manly Salesman manual report 6.2 Operations of Printing Report 6.2.1 Print Total Report Total reports are divided into total daily report, total monthly report, total quarterly report and total manual 64 report. Press "X" key to print the list of report information. The left side of list is report number, the right side of list is time information. Number-0 is today's report, normally. Input the number of report, press "Print" to print it. Total manual report would take operation A51 as time point to divide the storage. The buffer zone delays a position automatically when a report is cleared (That means: Buffer 31 records the information which was stored in buffer 30. By analogy, buffer 1 record the information which was stored in buffer 0 and information stored in buffer 0 is cleared. Then start accumulating in buffer 0. ). Example 6-1 Print Daily Reports of Today and Yesterday Display Operations Keys Remarks Weight/ Change/ Single/ Tare Count U.Price Total 0.000 0.000 0.00 0.00 〖Sale〗, 〖Sum〗 on. 『Sale Idle』 Enter Account A1 Total 【Account】 〖Account〗 on. 【1】: Total report 【2】: Dept. report Enter total report A11 Total Daily 【1】 【3】: Class report 【4】: PLU report 【1】: Daily report 【2】: Monthly report Enter total daily report Input 2–1 0 【1】 【3】: Quarterly report 【4】: Manual report Input start number 【0】 Input 2–2 0 Start from today. 【Confirm】 Input end number 【1】 … … … End at yesterday. 【Confirm】 … Print daily report of today. (错 A11 Total Daily 0 误!未找到引用源。) Print daily report of yesterday. A11 Total Daily 1 (错误!未找到引用源。) A11 Total Daily End of print. Return to sale mode 0.000 0.000 0.00 0.00 〖Sale〗, 〖Sum〗 on. 【Sale】 6.2.2 Print Department Report The scale could print report of all departments. Operation steps are similar as Print Total Report. Only the step to enter is different. 6.2.3 Print Class Report The scale could print reports of all Classes. Operation steps are similar as Print Total Report. Only the step to enter is different. 6.2.4 Print PLU Report The scale could print reports of all Classes. Operation steps are similar as Print Total Report. Only the step to enter is different. 65 6.3 Clear Report Information 6.3.1 Clear Report Information Manually The information in manual reports would not be cleared automatically unless users enter A51 (clear current manual report) interface to clear it. After this operation, manual reports of all departments, classes and PLU would be cleared, and total manual report would delay its serial number. Example 6-2 Clear Information in Manual Report Operations 『Sale Idle』 Enter Account Enter clear report Clear manual report Return to sale mode Keys Tare 0.000 A1 【Account】 A51 【5】 ---【1】 A51 0.000 【Sale】 Display Weight/ Change/ Count U.Price 0.000 0.00 Total Clear Manly ---------Clear Manly 0.000 0.00 Remarks Single/ Total 0.00 〖Sale〗, 〖Sum〗 on. 〖Account〗 on. ------- Wait a few seconds. 0.00 〖Sale〗, 〖Sum〗 on. 6.3.2 Clear All Reports and Records Information Example 6-3 Clear All Reports and Records Information Operations Keys Tare 『Sale Idle』 Enter Account Enter clear report Clear manual report 0.000 A1 A51 Display Remarks Weight/ Change/ Single/ Count U.Price Total 0.000 0.00 0.00 〖Sale〗, 〖Sum〗 on. Total 〖Account〗 on. Clear Manly Input Code 0 Input validate code. 【Account】 【5】 【2】 【9】【9】【5】 Input validate code 【8】 Confirm validate code 【Confirm】 -------A52 Clear Return to sale mode 0.000 0.000 【Sale】 -----All 0.00 ------0.00 〖Sale〗, 〖Sum〗 on. N o t e 1 This operation would clear the records of all deals. And it’s irreversible. Please operate it carefully. 6.3.3 Clear stock information Example 6-4 Clear stock information Operations Keys Tare 0.000 『Sale Idle』 Enter Account A1 【Account】 Enter clear report A51 【5】 Clear manual 【3】 report Input validate code 【9】 【9】 【5】 【8】 Display Weight/ Change/ Count U.Price 0.000 0.00 Total Clear Manly Input Code Single/ Total 0.00 0 Remarks 〖Sale〗, 〖Sum〗 on. 〖Account〗 on. Input validate code. 66 Confirm validate code Return to sale mode 【Confirm】 【Sale】 ---- ----- ------ A53 Clear Stock 0.000 0.000 0.00 N o t e 1 This operation would clear stock ------- 0.00 〖Sale〗, 〖Sum〗 on. report. And it’s irreversible. Please operate it carefully. 6.3.4 Reposition SID information Example 6-5 Clear manual report Operations 『Sale Idle』 Enter Account Enter clear report Clear manual report Return to sale mode Keys Tare Display Weight/ Change/ Count U.Price 0.000 0.00 Total Clear Manly 【Account】 【5】 0.000 A1 A51 【4】 ---- ----- ------ A54 Clear SID 0.000 0.000 0.00 【Sale】 Single/ Total 0.00 Remarks 〖Sale〗, 〖Sum〗 on. 〖Account〗 on. ------- Wait a few seconds. 0.00 〖Sale〗, 〖Sum〗 on. 6.4 Stock Management 6.4.1 Stock Management A6’s stock report and A44’s manual PLU report are choiceable( by Spec141) . Stock report only support first 1000 saved PLU, if the real input PLU number >1000, the partial PLU can notprocess stock management 6.4.2 Stcok Print When print stock report, it will clue to input 2 digits, scale will in turn print the stock report those PLU reports whose serial numbers is between the 2 input numbers as well as the 2 input numbers. Example 6-6 Print stock Reports with the Numbers from 10 to 20 Operations 『Sale Idle』 Enter Account Enter stock management Enter stock print Input start number Input end number Keys Display Change/ U.Price 0.00 【Account】 0.000 A1 【6】 A61 Stock Print Input 2–1 0 Input 2–2 0 Start from PLU10. … … … End to PLU20. 10 11 Print Print 【1】 【1】【0】 【Confirm】 【2】【0】 【Confirm】 Tare … Single/ Total 0.00 Remarks Weight/ Count 0.000 Total 〖Sale〗, 〖Sum〗 on. 〖Account〗 on. Print stock report of PLU10. Print stock report of PLU11. 67 Return to sale mode 【Sale】 0.000 0.000 … Print …… End of print. 0.00 0.00 〖Sale〗, 〖Sum〗 on. N o t e 1 If some stock reports store no data, these buffers would be skiped off without printing N o t e 2 If end number input is 0, system would only print the buffer appointed by start number. N o t e 3 If end number input is not 0 and less than start number, no buffer would be printed. 6.4.3 Stock Audit Example 6-7 Amend PLU10 stock to 100 Operations 『Sale Idle』 Enter Account Enter stock management Enter stock print Keys Weight/ Tare Count 0.000 0.000 Total 【Account】 A1 【6】 Amend to the imput number Return to sale mode Single/ Total 0.00 Stock Print Input PLU-no 0 A61 pcs 0 10 0.000 0.000 0.00 0.00 【2】 Remarks 〖Sale〗, 〖Sum〗 on. 〖Account〗 on. Pcs means default count unit. When PLU is for weight, default Present Stock unit PLUnumber stockunit is scale’s unit kg stock 【Amend】: amend stock to input pcs 100 10 【1】 【0】 【0】 A61 number 【Confirm】: add input number to stock pcs 100 10 【Amend】 A61 【F-Prog】+【Confirm】: reduce input number from stock 【1】【0】 Enter PLU number 【Confirm】 Enter stock quantity 100 A61 Display Change/ U.Price 0.00 【Sale】 〖Sale〗, 〖Sum〗 on. N o t e 1 Use【F-Prog】+【PLU】 can amend the stock unit, make the weight PLU also with count stock. Generally do not suggest user use this function. Detailed refer to Spec142 6.5 List Print 6.5.1 Sale Log When user sale in sale interface, sale data will be recorded. This recorded data is source of all account modes’ Stat. Date. Device has about 6000~10000 location according to different device’s configure. When the log is being over capability, device will delete oldest log according to FIFO rule. 6.5.2 List Print Example 6-8 Intraday List Print Operations 『Sale Idle』 Keys Tare 0.000 Display Weight/ Change/ Count U.Price 0.000 0.00 Single/ Total 0.00 Remarks 〖Sale〗, 〖Sum〗 on. 68 Enter Account Enter stock management 【Account】 A1 Total 【7】 A71 List Enter stock print 【1】 Start print 【Confirm】 Return to sale mode 【Sale】 A71 0.000 List 0.000 〖Account〗 on. Print Print 20 1 2 … Print Print Print 0.00 0.00 Last window display the location number used by intraday Print first unit’s record Print second unit’s record …… Print finished 〖Sale〗, 〖Sum〗 on Example 6-9 Appointed Time Period List Print Operations 『Sale Idle』 Enter Account Enter stock management Keys 【Account】 Display Weight/ Change/ Tare Count U.Price 0.000 0.000 0.00 A1 Total Single/ Total 0.00 【7】 A71 List Print Enter stock print 【1】 A71 List Print Enter time period 【×】 Input 01 01 …… Input 01 01 …… Time-1 00 00 …… Time-2 23 59 …… List Print 30 1 2 … Print Print Print 0.00 0.00 Enter start time 2009 【…】 【Confirm】 … Enter finish time 2009 【…】 【Confirm】 … A71 Start print 【Confirm】 Return to sale mode 【Sale】 0.000 0.000 20 Remarks 〖Sale〗, 〖Sum〗 on. 〖Account〗 on. Last window display the location number used by intraday 00 W-4 …… 59 W-4 …… Last window display the location number used by appointed time period Print first unit’s record Print second unit’s record …… End print 〖Sale〗, 〖Sum〗 on 69 7 Appendix 7.1 Reference Table For Errors and Its Instructions Number E0.00 E0.01 Alarm instructions Alarms for measurements Weight is not stable when the scale start-up. Methods to handle Make sure there is no heavy goods on the tray and the tray is stable. If scale still warns, the sensor may go wrong. Make sure there is no heavy goods on the tray and the tray is on the bracket, If scale still warns, the sensor may go wrong. E0.02 Exceed the allowed start-up zero range E1.00 E1.01 Alarms for operations Prog data is invalid. Input passwords of 2 times to amend password are different Input valid data again. Re-amend password, and make sure 2 times input are the same. E1.03 The selected print format do not exist Set print format again E1.10 Sale at 0 price is forbidden. E1.11 Exceed the largest sale price. E1.12 E1.13 Need to return to zero point Exceed accumulative limit There is data in buffer and cannot print in single. No cashing mode, cannot executethe cashing operation. Cashing mode with zero change default is forbidden. Payment is less than sale price. System cannot execute accumulative operations while locking PLU. System cannot switch buffers into buffer with accumulation while locking PLU. Not allow no weigh sale for weight goods Less than smallest sale weight Larger than largest sale weight Discounted U.Price has to be less than discount lower limit. Discounted U.Price has to be higher than discount upper limit. Discount is forbidden. Manual weight entry is forbidden Manual weight entry failed for weight is not zero. E1.02 E1.14 E1.15 E1.16 E1.17 E1.18 E1.19 E1.20 E1.21 E1.22 E1.23 E1.24 E1.25 E1.26 E1.27 The sale whose sell price is 0 is forbidden. Refer to Spec070. Total price or grand total price of sold goods exceeds the largest sale price. Return to weight zero before sale. Refer to Spec069. The accumulative times are over buffer accumulat limit Print the data in buffers first. Then print this sale or switch to other buffers. The scale is set to be no cashing mode. Refer to Spec060. Execute cashing operation afer inputing payment amount. Refer to Spec060. Charge enough money which is larger than sale price. Before accumulative operations, system needs to exit lock PLU (or auto mode) first. Operate in current buffern, or exit lock PLU (or auto mode). Refer to Spec071. Weight needs to be larger than smallest sale weight. Weight needs to be smaller than largest sale weight. Discounted in allowed range, or amend the allowed range. Refer to Spec110 Refer to Spec077 Take off goods, or press 【Zero】 70 Number E1.28 E1.29 E1.30 E1.31 E1.32 Alarm instructions T-Sale is forbidden Sale of Weight PLU or count PLU is forbidden. Can not enter special sale mode Working on forced auto printing after zero-return. PLU Quiting is forbidden. Transfer sale buffer is forbidden under accumulate mode Methods to handle Refer to Spec076 Refer to Spec075 Selected PLU haveconflict with special sale mode, select again Finish printing of current PLU. Press 【 Confirm 】 or 【 Cancell 】 exit the accumulate mode,then go on transfer E1.33 Transfer sale mode forbidden Refer to Spec079 E1.34 The scanned barcode can not be parsed Confirm the scanned PLU have been edited, interior barcode format station right E1.35 Tare renew function forbidden Must turn over tare, then go for tare E1.36 Salesman is not exist Login with exist personel E1.37 Salesman’s password can not be 0 Login with personel whose password is not 0 E1.38 Service charge is forbidden Open the function at Spec307 Custom Product Alarm E1.50~E1.59 Forbid F-Prog of PLU Forbid F-Prog of PLU shortcut keys Forbid F-Prog of Spec data parameters Forbid Re-print Menu quiting via pressing 【 Sale 】 【Prog】【Account】 is forbidden. Refer to Spec080. Refer to Spec081. Refer to Spec082. Refer to Spec065. E2.06 A44 report forbidden Refer to Spec141. E2.07 A6 report forbidden Refer to Spec141. E2.09 Illegal reboot Refer to Spec138. E6.00 Alarms for peripheral E1.5x E2.01 E2.02 E2.03 E2.04 E2.05 E6.10 PTR: Print sensor calibrate wrong E6.11 PTR: Gap paper is not taken away. E6.12 E6.13 E6.14 PTR: Print mouth is not closed tight. PTR: Printer is working. PTR: Lack of plain paper E6.15 PTR: Lack of gap paper E6.16 PTR: The printer cannot find the gap intervals. E6.17 E6.18 PTR: The printer cannot find gap alignment positions. PTR: The printer is overheated and it needs to cool down. Quit the menu by press【Cancel】some times. Do calibrate operation with Ethernet Printer Take away the printed label paper. If the alarm still warns, do calibrate operation with Ethernet Printer Install the paper and close mouth. Please wait for a few seconds and try again. Reinstall plain paper or the paper type cannot match. Reinstall label paper or the paper type cannot match. If the alarm still warns, do calibrate operation with Ethernet Printer The paper type cannot match and change the type to plain paper or reinstall gap label paper. If the alarm still warns, do calibrate operation with Ethernet Printer Label paper is used up or paper type cannot match with set paper type. Please reinstall label paper. Please wait for a few seconds and try again. 71 Number E6.19 Alarm instructions PTR: There is no response of the printer. E6.20 PTR: Print sensor calibrate wrong E6.21 PTR: Communication Error E7.00 Some keys are pressed when the scale starts. E7.10 Print sensor calibrate wrong E7.11 Gap paper is not taken away. E7.12 E7.13 E7.14 Print mouth is not closed tight. Printer is working. Lack of plain paper E7.15 Lack of gap paper E7.16 The scale cannot find the gap intervals. E7.18 E7.19 The scale cannot find gap alignment positions. The printer is overheated and it needs to cool down. There is no response of the printer. E7.20 The printer over time E7.23 PDS calibration failed, ignore PDS E7.30 E7.40 Alarm for full storage of deals records. Time error E7.50 E7.51 E7.52 Printer process do not follow general time order and finish the working, unknown print error Checkup the Ethernet cable Alarms for hardwares E7.01 E7.17 Methods to handle The printer may not be connected or in the state that the printer could not print. Please confirm that no keys are pressed. In this interface, the last window display pressed keys. 8-5 means the key in 8th column from the left and 5th row from the top is pressed. In this interface, the second window displays the calibrated times. Refer to chapter 1.5.5 Abnormity of Gap Paper Print to calibrate again Take away the printed label paper. If there is still alarm this problem, do as the way in chapter 1.5.5 Abnormity of Gap Paper Print to detect. Install the paper and close mouth. Please wait for a few seconds and try again. Reinstall plain paper or the paper type cannot match. Reinstall label paper or the paper type cannot match. If there is still alarm this problem, do as the way in chapter 1.5.5 Abnormity of Gap Paper Print to detect. The paper type cannot match and change the type to plain paper or reinstall gap label paper. If there is still alarm this problem, do as the way in chapter 1.5.5 Abnormity of Gap Paper Print to detect. Label paper is used up or paper type cannot match with set paper type. Please reinstall label paper. Please wait for a few seconds and try again. The printer may not be connected or in the state that the printer could not print. Printer process do not follow general time order and finish the working, unknown print error Try reclibrate, this failure will not effect general use Enter Account interface. Calculate reports and then clear the reports. Time module error, if scale work for years, then it means to change the battery on main board Inside examine and repair code, if restart again andagain, Harware error but still exist this question, need return to factory for repair 72 Number Alarm instructions Methods to handle E7.53 E7.54 Font file check error Download font from Software again. E7.61 No MAC device Please ask Service for MAC file. Wire-Network module do not exist or If no wire-network module in present scheme, please working irregular close the network module (Set Spec043=0) . Wireless-Network module do not exist If no wireless-network module in present scheme, please or working irregular choose wire-network module (Set Spec050=0) . AD work irregular or loadcell irregular Confirm loadcell install right E7.62 E7.63 E7.70 If device is working with battery, please charge it first. E7.81 DC power is too low If user confirm that power is right, please set Spec235=1 to close the power detect module If device is working with battery, it means battery is not E7.82 match with the device. DC power is too high If user confirm that power is right, please set Spec235=1 to close the power detect module E8.00 Alarms for communications E8.11 USB flash disk port do not connect with the scale. E8.12 USB flash disk does not exist. E8.13 The file in USB flash disk does not exist. Please confirm that the scale used owns U-Disk port. If it owns, and this alarm cannot be cleared after several times’ reboot, please use the guarantee. Please confirm that USB-Disk is correctly inserted with two condition: 1. USB-Disk is formatted in FAT12/16/32. NTFS is not supported by device. 2. USB-Disk is bootloaded as FDD. HDD/ZIP are not supported by device. Confirm that appointed files are inside of USB flash disk. 7.2 Definitions of Spec data parameters Default values are different via different version. Value list blow is cfor reference only. No. 0 1 2 3 4 5 Content Range Remarks Default Permission 0 means not to print, 1~99 are to print in appoint Bill 1: Item Print Format 0~99 1 0 Print formats. 0 means not to print, 1~99 are to print in appoint Bill 1: Item Barcode Format 0~99 2 0 barcode formats. 0~ Bill 1: Item Barcode flag 20 0 9999999 Bill 1: Item Print Times 0~99 1 1 Bill 1: Item Print Reverse 0~1 0: No Reverse, 1: Print 180°Reversed 0 1 0 means not to print, 1~99 are to print in appoint Bill 1: Sum Print Format 0~99 4 0 Print formats. 73 No. Content 6 Bill 1: Sum Barcode Format 7 Bill 1: Sum Barcode Flag 8 Bill 1: Sum Item Print Times 9 Bill 1: Sum Print Reverse 10 Bill 2: Item Print Format 11 Bill 2: Item Barcode Format 12 Bill 2: Item Barcode Flag 13 Bill 2: Item Print Times 14 Bill 2: Item Print Reverse 15 Bill 2: Sum Print Format 16 Bill 2: Sum Barcode Format 17 Bill 2 Sum Barcode Flag Range Remarks Default Permission 0 means not to print, 1~99 are to print in appoint 7 0 0~99 barcode formats. 0~ 209999 0 9999999 9 0~99 1 1 0~1 0: No Reverse, 1: Print 180°Reversed 0 1 0~99 0 1 0~99 0 1 0~ 0 1 9999999 0~99 For the second-class Print formats, ordinary 0 1 0~1 users won’t use them. 0 1 0~99 Please don’t amend them in normal conditions. 0 1 0~99 0 1 0~ 0 1 9999999 0~99 0 1 0~1 0 1 0~99 Reduced % of paper speed 0 1 0~1 0: Plain Paper, 1: Gap Paper. 1 0 0~15 0 is lightest, 9 is darkest. The print lighter, the 5 0 0~15 damage to print header smaller. 5 0 18 Bill 2: Sum Item Print Times 19 Bill 2: Sum Print Reverse 20 Print Speed Slow Down 21 Paper Type 22 Gray Level of Gap Paper 23 Gray Level of Plain Paper Plain Paper: Interval of Each 24 0~99 0 Print Unit of setting number is mm. 25 Plain Paper: Cut-off Position 0~99 35 Plain Paper: Pre-feed Unit of setting number is dot. 26 0~1999 16 Distance Device is reverse feed if number > 1000 27 Wide of Report Printing 0~99 Unit of setting number is mm. 50 28 Font for Report Print 0~2 1 Continuously print appointed time will enter 29 Heat Protect 0~30 5 over-heat protect, Please don’t amend it. Hardware properties. Please don’t amend them 180 30 Feed Sensor Position 0~255 without the guidance of professionals. Narrow Bar Dot Number of 31 0~9 0 Barcode 0 for Default Wide Bar Dot Number of 32 0~19 0 Barcode Font of Barcode readable 33 0~2 0 character Weighing's Anti-shake while Hardware property, Please don’t amend them 3 34 0~19 without the guidance of professionals. Printing 35 Auto New Line Mode 0~1 0: Forbidden; 1: Allowed 0 0: No frame; 1: Up and down frame; 36 ITF25 frame mode 0~2 1 2: Around frame 37 ITF25 frame width 0~31 Frame dots 8 0 0 0 0 1 1 1 1 1 1 1 1 1 1 74 No. 38 Content ITF25 left and right blank width Range Remarks 20 1 39 Gap Paper: Pre-feed Distance 0~1999 0 0 40 Device Number 0 0 41 RS232 Baud Rate 5 0 1 1 0 0 0 0 1 1 0 1 0 1 10 1 0 1 0 1 1 1 1 1 2 1 0 1 0 0 1 1 1 0 3 0 3 0 3 0 3 0 42 USB flash disk Auto Update 43 Ethernet Mode 44 Ethernet Auto Re-connect 45 Ethernet Auto Reboot if Configure Changed 46 Latency Time of USB Linking 47 USB Power Always ON 48 Ethernet Overtime Interval 49 Password Authorization 50 Ethernet Type (Need Reset) 51 Security Mode 52 Security Option 53 Domain Type 56 Print Function 57 59 RS232 POS Protocol Sale Log Auto Save 60 Cashing Mode 61 Drawer In Sale Operation 62 Press【Drawer】in Sale 63 Press【Drawer】in Prog 64 Press【Drawer】in Account 0~31 Left and right blank dots Default Permission Unit of setting number is dot. Device is reverse feed if number > 1000 0~ They are used to distinguish more than one 9999999 scale. And they can be printed. 0: 300, 1: 600, 2: 1200, 3: 2400, 4: 4800, 5: 0~9 9600, 6: 19200, 7: 38400, 8: 57600, 9: 115200. 0~1 0: No Update, 1: Auto Update 0~2 0: Disable; 1: Server Mode; 2: Client Mode 0: do not try connect again 0~65535 1~65535: Device will try to connect with PC each appointed second 0: Disable, only reset change Ethernet config. 0~1 1: Enable, Ethernet config apply immediately. 0: Default wait 2s; 1~99: wait0.1s--9.9s. Suggest clients keep the default set. If some 0~99 U-disk start slowly, you can try to change the waiting time for longer 0~1 1: Enable Single overtime seconds, over 5 times overtime, 0~31 Ethernet will disconnect 0: Device Operation Only 0~1 1: Communication Operation Allowed 0~1 0: Wire-Network; 1: Wireless-Network 0~2 0: No Security; 1: WEP; 2: WPA/WPA2 0~1 0: Open System; 1: Shared Key 0: FCC; 1: IC; 2: ETSI; 3: Spain; 4: France; 5: 0~6 JapanA; 6: JapanB 0:Print All as setting; 1:Print Bill 1; 0 2:Print Bill 2; 3:Print in PTR; 4:Print Forbidden 0~99 Refer to POS Protocol File 0~1 1: Sale Log Auto Save to USB-Disk in Account 0: No Cashing Mode, 1: Cashing Mode With Zero Change Default, No Display For Zero Change, 0~3 2: Cashing Mode With Zero Change Default, Always Display For Zero Change, 3: Cashing Mode Without Zero Change Default. 0~3 0: Not Open Drawer, 1: Open Drawer 1, 2: Open Drawer 2, 3: Open Drawer 1 and 2. 0~3 For general scale, only drawer 1 is valid, if user have double drawer request, please contact us. 0~3 The added drawer password only limit the 【Drawer】operation, open the drawer while 0~3 printing is not limited 75 No. Content 65 Reprint 66 Change Display Exit 67 Number Tare 68 PLU Tare 69 Zero-Return For Weight Sale 70 Range Remarks Default Permission 0: Reprint Forbidden 1: Print One Piece of Bill 1 0~4 2: Print One Piece of Bill 2 3 1 3: Print Each Piece of Bill 1 and 2 4: Print Bill 1 and 2 as Sale Operation 0: Push Any Key For Exit, 0~99 0 0 1~99: Auto Quit Exit Specified Second 0: Forbidden, 1: Input Value Tare, 0~2 0 0 2: Floating-point Value Tare. 0: Forbidden, No Resume Tare 1: Update If Current Tare Is Zero, No Resume Tare 2. Update if PLU Tare Is Not Zero, No Resume Tare 3. Always Update PLU Tare, No Resume Tare 0~7 1 0 4: Forbidden, Resume Tare 5: Update If Current Tare Is Zero, Resume Tare 6. Update if PLU Tare Is Not Zero, Resume Tare 7. Always Update PLU Tare, Resume Tare 0: Always need Zero-Return; 0~2 1: Zero-Return is need if Weight Changed; 1 0 2: No Zero-Return need, Print "*" before weight 0~1 0: Forbid; 1: Allow 0 1 0: Forbid; 1: Allowed, 1 pc only 0~2 0 0 2: Allowed, multi pcs allowed 74 Allowed Zero Purchase No Weigh Sale for Weight PLU Clear Sale Buffer if Press 【Sale】 Think【T-Sale】As【U.Price Convert】 Return of Goods 75 PLU forbidden 0~3 76 T-Sale PLU transfer forbidden 0~3 77 Manual Weight Entry 0~3 78 【Auto mode】Get into Special Sale Mode 0~4 71 72 73 79 80 81 82 83 Sale mode select PLU Fast-Prog ScPLU Fast-Prog Spec Fast-Prog Unit Price Fast-Prog 【[email protected]】 or 【@Price】 0~1 0~1 0~1 0~1 0~1 0~1 0~1 0~3 0: Not clear, 1: Clear. 0: Forbid; 1: Allow. Convert the input U.Price unit from T-Sale Unit to Scale unit. 0: Forbid, 1: Allow. 0: No forbidden; 1: Weight PLU forbidden; 2: Count PLU forbidden; 3: All PLU forbidden. 0: No forbidden; 1: T-Sale Weight PLU forbidden; 2: T-Sale Count PLU forbidden; 3: All T-Sale PLU forbidden; 0: Disable, 1-3: Enable 0: Auto mode forbidden 1: Swith to batch print mode 2: Swith to prepack print mode 3: Swith to lock PLU mode 4: Swith to auto print mode 0: Forbid, 1: Allow. 0: Forbid, 1: Allow. 0: Forbid, 1: Allow. 0: Forbid, 1: Allow. 0: Forbid; 1: long press【[email protected]】 change PLU saved unit price 0 0 0 0 0 0 0 1 0 1 0 0 2 0 1 1 1 1 0 0 0 0 1 1 76 No. 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 Content Range Remarks Default Permission 2: press【[email protected]】change PLU default unit price 3: press【[email protected]】change PLU default unit price, long press to enter PLUsaved name edit menu Wait several seconds after pressing the key to set Stable Waiting: Set Zero 0~99 zero. If it’s stable in time, execute setting zero. If 20 0 (Each 10 for 1 Second) not stable, error beep would sound. Wait several seconds after pressing accumulative Stable Waiting: Sale 0~99 or print in sale. If it’s stable in time, execute sale. 20 0 (Each 10 for 1 Second) If not stable, error beep would sound. 0: Disable; 1: Use dummy PLU, when try to transfer one do not exist PLU, device will use this PLU number or other PLU item empty way 0 1 Dummy PLU 0~1 to transfer a dummy PLU. For example:: PLU156 do not exist, when transfer, you will get a cargo name PLU-0156 ‘s PLU. 0: Disable 1: use dummy ScPLU, if one shout cut key have been edited, then when it is transferred, scale 0 1 Dummy ScPLU 0~1 will transfer PLU according to its short cut code. 【SC1】refer to PLU101, 【Shift】 【SC1】 refer to PLU201. Etc. Step-skip of PLU Fast-Prog 0: Disable; 0~1 1 1 Equal to PLU Prog 1: Enable, P331 and P332 do same effect Allow the scale to calculate report data in Calculating Account 1 1 0~1 background. Suggest clients do not edit this item Backgroud Log record function 0~1 0: Enable, 1: Disable 0 1 0: use old version, PLU is 10~5999 Dummy PLU number 0~1 1: PLU is 1~9999999, temporary PLU number 1 1 decided by Spec093 and 096 Dummy number for 0~ 999999 1 Temporary weight PLU 9999999 9 Dummy number for 0~ 999999 1 Temporary count PLU 9999999 8 Refer to Spec092 Dummy number for Service 0~ 999999 1 Charge PLU 9999999 7 Dummy number for Discount 0~ 999999 1 & Rounding PLU 9999999 6 0: Forbidden; 1: Allow use number index Index barcode from keyboard 0~2 1 1 2: Allow use number and character index 0: Not Record Single count deal: discount sum and rounding 0~5 1: Independent Record Discount, No Rounding 3 1 2: Separate Record Discount, No Rounding sum’smanage 3: Independent Record Discount and Rounding Accumulate deal: discount 4: Independent Record Discount, Separate sum and rounding 0~5 3 1 Record Rounding sum’smanage 5: Separate Record Discount and Rounding 77 No. 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 Content Range Remarks Default Permission 0, Common Rounding For Redundancy Digit 1, Common Rounding For Last Digit Rounding Method for Single 2, Common Rounding For Last 2 Digits 0~1 0 0 Total Price 3, Banker's Rounding For Redundancy Digit 4, Banker's Rounding For Last Digit 5, Banker's Rounding For Last 2 Digits 6, Rounding Down For Redundancy Digit 7, Rounding Down For Last Digit Rounding Method for Sum 8, Rounding Down For Last 2 Digits 0~11 0 0 Tota Pricel 9, Rounding to 0/5 For Last Digit 10, Rounding to 0/5 For Last 2 Digits 11, Rounding to 0/5 For Last 3 Digits Print with accumulated data 0~1 0: Enable, 1: Disable 0 1 Equal Reparation of Tare, 0: No Reparation; 1: Tare=Gross-Net; 0~3 3 1 Net and Gross 2: Net=Gross-Tare; 3: Gross=Net+Tare 0: YYYY.MM.DD; 1: YY.MM.DD Date Type 0~5 2: MM/DD/YY; 3: MM-DD-YY 0 1 4: DD/MM/YY; 5: DD-MM-YY 0: Using PLU setting 1: Shelf Printing based-on Spec106 if PLU Do 0 0 Shelf Day Print 0~2 not set Shelf Day 2: Shelf Printing based-on Spec106 Shelf life days after intraday. Shelf Days 0~999 0 0 0 means only for intraday Number of Sale Buffers 0~99 0: maximum allowed buffer 0 0 Number of Maximum 0~65535 0: maximum allowed accumulate 0 0 Accumulate Divide Operation of U.Price 0~1 0: Normal Operation; 1: Divide Operation 0 Not open 0, All Allowed 1, Forbidden U.Price Discount Manual Discount: Forbidden 0~3 0 1 2, Forbidden T.Price Discount 3, Forbidden All Discount 0: no lower limit, discount freely; Manual Discount: 1~99: Take the percent of U.Price as the lower Lower Limit 0~255 limit of the discount. 0 0 (Percent Number) 100~255: Don’t allow the price after manual discount is lower than original U.Price. 0: no upper limit, discount freely; Manual Discount: 1~100: Don’t allow the price after manual Upper Limit 0~255 discount is higher than original U.Price. 0 0 (Percent Number) 101~255: Take the percent of U.Price as the upper limit of the discount. Percent Discount Arithmetic 0~1 0: Subtracter, 1: Addition 0 1 0: Manual input number 0 1 Auto Percent Discount Rate 0~99 1~99: Discount with this number 78 No. Content Range 115 Auto Discount: Price Lock 0~3 116 Global Tax Sort 0~3 117 Global tax rate(‱) 118 Amend mode in sale 119 Scanner checkout 120 Bar code match calculation 121 Deal method with code=0 122 Internal Barcode 1: Format 123 124 125 126 127 128 129 130 131 Internal Barcode 1: Flag Number Internal Barcode 2: Format Internal Barcode 2: Flag Number Internal Barcode 3: Format Internal Barcode 3: Flag Number Internal Barcode 4: Format Internal Barcode 4: Flag Number Total Price Masked before Printing Auto Printing after Zero-return Remarks 0: No Auto Discount 1: Price Lock if Auto Discount Is Effective 2: Price Lock If Auto Discount Is Setting 3: Price Lock for All PLU Price Discount disable when price is tracking. 0: No global tax rate 1: Default is exclude Tax with Excluded Rate 2: Default is include Tax with Excluded Rate 3: Defaultx with included Rate 0~9999 0.01% tax rate, for 17%, need input 1700 0: Manual; 0~2 1: Record and clear 2: Not record and clear 0: Not checkout, ignore reduncdance information 0~2 1: Checkout, ignore reduncdance information 2: Checkout, not ignore reduncdance information 0: Do nothing 1: Deal with External Barcode (Index mode) 0~3 2: Deal with Internal Barcode (Code mode) 3: Deal with all mode 0: Search user PLU 0~2 1: Deal with By-Weight T-Sale PLU 2: Deal with By-Count T-Sale PLU Group 1 interior bar code format, if Spec122=0, 0~99 device auto use Spec1 and Spec2 as Group 1 interior bar code format 0~ 9999999 0~99 Group 2 interior bar code format 0~ 9999999 0~99 Group 3 interior bar code format 0~ 9999999 0~99 Group 4 interior bar code format 0~ 9999999 0: Not enable 0~1 1: Enable. Total Price only displays after printing 0: Not enable. 1: Auto record after Zero-return. Can press 【Cancel】to exit, do not record after exit 0~4 2: Forced auto record after Zero-return. Force operator to print the trade or take record. 3: Auto Printing after Zero-return. Can press 【Cancel】to exit, do not record after exit Default Permission 1 1 1 0 1 0 0 1 2 1 3 1 1 1 0 0 0 0 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 79 No. 132 133 134 Content Accu Mode: Transferring PLU by Key Input Accu Mode: Transferring PLU by External Barcode Accu Mode: Transferring PLU by Internal Barcode Range Remarks Default Permission 4: Forced Auto Printing after Zero-return. Force operator to print the trade or take record. 0~1 0~1 0: Disable 1: Enable 0~1 0: No salesman mode, log in with salesman 0. 1: Login V1~V4 with Salesman 1~4, No password 2: Password Enable, V1~V4 by Same Salesman 135 Salesman mode 0~5 3: Password Enable, V1~V4 by Different Salesman 4: Password Enable, V1~V4 by Same Salesman, Pass=0 Salesman Cannot login 5: Password Enable, V1~V4 by Different Salesman, Pass=0 Salesman Cannot login 0: Disable 136 Waiter Mode 0~2 1: Enable, Forbidden dummy personnel 2: Enable, Allowed dummy personnel 0: Always clear; 1: Memory last one 137 Waiter Memory Mode 0~2 2: Memory in buffer 138 Right of Default Salesman 0~65535 Please use software 139 EAN/UCC CRC 0~1 0: Standard, 1: Non-standard 0: Disable; 1: Half day clear(12:00 and 0:00) 2: Each day clear; 3: Each Saturday clear 140 SID auto clear 0~6 4: Each Monday clear; 5:Each month clear 6: Each quarter clear 0: Disable(A44 Report Enable) 141 Stock report 0~1 1: Enable(A44 Report Disable) 0: Only PLU's Unit Allowed 1: Default By-Weight Unit and By-Count Unit 142 Stock change unit mode 0~2 Allowed 2: All System Unit Allowed 0: Print as number 143 FID/SID Print Mode 0~9 1~9: Print in specified length with ’#’ 144 Each Item has Indentify FID 0~1 0: Forbidden; 1: Enable. +1: Print Picture 1; +2: Print global text 0 145 Print extra info in report 0~65535 +4: Print global text 1; +8…… 150 0~255 When Spec153 is 0, device will connect to 151 0~255 Scale’s Ethernet IP network by DHCP. Otherwise use appointed IP 152 0~255 to connect the network 153 0~255 154 0~255 When the network under clients PC’s Ethernet IP 155 0~255 state( Spec043=2) , appoint PC’s IP. 156 0~255 0 1 1 1 1 1 1 0 0 1 0 1 0 0 1 1 2 1 1 1 1 1 6 1 0 1 0 1 192 168 0 0 0 0 0 0 0 0 0 0 0 0 80 No. 157 158 159 160 161 162 163 164 165 166 167 168 169 170 171 172 173 180 181 182 185 186 187 188 189 190 191 192 193 194 195 196 197 198 199 200 Content Range Remarks 0~255 0~255 0~255 Scale’s Ethernet gateway Getway: not use DHCP to connect to network 0~255 0~255 0~255 0~255 Scale’s Ethernet mask Getway: not use DHCP to connect to network 0~255 0~255 Scale’s server port 0~65535 Do not change such setting unless there are Scale’s clients port 0~65535 expert! Irrelevant change will make the network Scale’s UDP local port 0~65535 do not work Scale’s UDP remote port 0~65535 0~255 0~255 Primary DNS Primary DNS for dns analysis 0~255 0~255 Display and Printing of 0: Dot’.’; 0~1 Radix Point 1: Comma’,’ 0: Not printing; 1: Dot’.’; Printing of Kilocharacter 0~3 2: Comma’,’ 3: Quotation Mark’ '’ Display of Kilocharacter 0~1 0: Not display; 1: Display based on Spec181 Unit Printing of Weight 0~1 0: No printing; 1: Printing Unit Priting of Unit Price 0~1 0: No printing; 1: Printing Unit Priting of Money 0~1 0: No printing; 1: Printing Unit Price Length 0~6 0: Use System Length; 1~6: Specified Length Total Price Length 0~7 0: Use System Length; 1~7: Specified Length 5-Windows Scale: 0: Auto Fix PLU Name Display 1: Font 1 Display 0~3 2: Font 0 Display 5-Windows Scale: 3: 2-Line Mode AD-Message display 5-Windows Scale: 0: Display Time; 1~3: Reserved 0~23 Display in Idle Mode 4~23: Global String data of Scale (0~19) 5-Windows Scale: 0: Display Accumulation Information Display in accumulated mode 1: Display AD-Message 5-Windows Scale: 0~7 PLU Info Text Source 1 0: PLU Name 1~7: Text1~7 5-Windows Scale: 0~7 PLU Info Text Source 2 Decimal Point of Count In 0~5 Similar as spec208 Barcode Print Fast Track of Weighing 0~4 0: Default level, 1~4: the bigger, the faster Delay of Zero Judgement 0~19 100ms per one Delay of Stable Judgement 0~19 Decimal Point: Tare 0~3 In default state, decimal digits of tare. Default Permission 0 0 192 0 168 0 0 0 1 0 255 0 255 0 255 0 0 0 33581 1 33582 1 33583 1 33584 1 8 0 8 0 8 0 8 0 0 2 0 2 0 0 0 0 0 0 2 1 1 1 1 1 3 1 3 1 3 1 3 1 0 1 0 1 3 1 0 4 0 3 1 1 1 1 81 No. Content 201 Decimal Point: Weight 202 Decimal Point: U.Price 203 Decimal Point: T.Price 204 Decimal Point Fix: Tare 205 Decimal Point Fix: Weight 206 Decimal Point Fix: U.Price 207 Decimal Point Fix: T.Price 208 Decimal Point of Weight In Barcode Print 209 Decimal Point of Money In Barcode Print 210 T-Sale Unit 211 System U.Price Unit 212 System Weight Unit 213 Weight Precision 214 Default measure sort 215 Maxium Overflow Degree 216 Maxium Underflow Degree 217 Minium Sale Degree 218 Zero Tracking Degree Range 0~3 0~5 0~5 0~1 0~1 Remarks Default Permission In default state, decimal digits of weight. 3 1 In default state, decimal digits of U.Price. 2 1 In default state, decimal digits of T.Price. 2 1 Fix display decimal point according to Spec200 0 1 Fix display decimal point according to Spec201 0 1 Fix display decimal point according to Spec202 0~3 0: No Fix; 1: Fix for Discount; 3 1 2: Fix for PLU Call Out; 3: Always Fix. Fix display decimal point according to Spec203. 0~2 0: No Fix; 1: Fix based on Spec100; 1 1 2: Common rounding before fix based on Spec100 For number 1.533, if number here is 2, print 153 3 1 0~5 when print barcode. If number here is 3, print 1533. The rest may be deduced by analogy. 0~5 Generally suggest Spec208=Spec201, 2 1 Spec209=Spec203 0, 1, 2: System Default; 0~8 3: kg Unit; 0 1 4: g Unit; 5: ton Unit; 6: lb Unit; 7: 500g Unit; 8: 100g Unit; 0~8 There are some relations among 3 units. 0 1 Relations are a little different in different 0~8 editions because the measuring systems are 3 1 different in different countries. 0: 10g, 3000 1: 5g/10g, 6000/3000 TM-30A 30kg 2: 2g/5g, 15000/6000 3: 1g/2g, 30000/15000 0: 5g, 3000 1: 2g/5g, 7500/3000 TM-15A 15kg 2: 1g/2g, 15000/7500 3: 0.5g/1g, 30000/15000 0~3 1 1 0: 2g, 3000 1: 1g/2g, 6000/3000 TM-6A 6kg 2: 0.5g/1g, 12000/6000 3: 0.2g/0.5g, 30000/12000 Only precisions of unit kg are listed here. Other units may be a little different. When users use precisions of 2 or 3, weight print would display “*” which means it’s only for industrial use. 0: Non-input PLU is by-weight as default 0~1 0 1 1: Non-input PLU is by-count as default 0~99 9 1 0~99 Degree number, there is no limit if number is 0. 9 1 0~99 4 1 0~99999 Unit is: e/10 0 2 82 No. 219 220 221 222 223 224 225 226 227 228 229 230 231 232 233 234 235 236 237 238 239 244 245 246 247 Content Range Remarks Default Permission Tare Range 0~99 0 2 Range of the Initial Zero 0~99 9 2 Range of the Single Manual 0~99 Percentage number. No limit if number is 0. 2 2 Zero Range of the Accumulative 0~99 2 2 Manual Zero Zero Flag Range 0~99 4 2 Zero Tracking Range 0~99 Inter-code 5 2 Stable Flag Range 0~99 6 2 Tare can Overrun Capacity 1 0~1 0: Forbidden; 1: Allowed 0 1 Tare Update 0~1 0: Forbidden; 1: Allowed 1 1 Price Convert betweent 0: Allowed; 1: Only Default Weight Allowed 0~2 0 1 Different Weight Unit 2: Forbidden 0: Forbidden; 1: Long Press to Switch; Weight Switch 0~2 1 1 2: Single Press to Switch AD Anti-shake while printing 0~7 Hardware parameter 2 1 Zero forbidden in PLU Mode 0~1 0: Zero is allowed; 1: Zero is forbidden 0 1 0: Always based on low capability Floating-point of weight 0~2 1: Based on current capability, low is priority 0 1 2: Based on current capability, high is priority Zero back is necessary for 0: No need 0~1 0 1 fast weight unit switch 1: Need Degrees of Zero back 0~31 Judgement Value of Zero back 0 1 Power Detect Module 0~1 0: Enable; 1: Disable 0 1 Print in Battery Mode 0~1 0: Print; 1: Not print 0 1 Interval of Key Scanner 0~4 Hardware parameter 1 1 Anti-shake of Key Scanner 0~4 Hardware parameter 1 1 Time for open drawer 0~9999 0~9999ms. Default 100ms 100 1 Ignore PBS Sensor 0~1 Use to oblige elimate error E7.12 0 1 Ignore PDS Sensor 0~1 Use to oblige elimate error E7.11 0 1 Ignore PPS Sensor 0~1 Use to oblige elimate error E7.14 0 1 Password is memoried and no need to input again once it is input. Memory is cleared on restart or parameter amend. Password hold function 0~3 0: Not hold any password 0 1 1: Only hold drawer password 2: Hold all password except admin password 3: Hold all password 249 PLU Text Mode: PLU Text Length ≈ Total Length-150 0~4 0: Default 1: 256 Bytes Mode; 2: 512 Bytes Mode 3: 1024 Bytes Mode; 4: 2048 Bytes Mode 0 1 250 No-Accumulation Mode 【Accu】is Doing Same Operation as【Print】 0~1 0: Disable this mode 1: Enable this mode 0 1 83 No. Content Range Remarks Default Permission 0: Disable discount menu 251 Discount Menu of Unit Price 0~4 1: Enable, default mode is based on【Key】 0 1 2: Enable, default mode is PERCENT mode 252 Discount Menu of Total Price 0~4 3: Enable, default mode is MINUS mode 0 1 4: Enable, default mode is FIX mode Call PLU by “Item-Code” 0: Based on PLU number 0 1 253 0~1 1: Based on PLU Item-Code when Press 【PLU】 0: Disable; 1: Enable in idle mode 254 0~3 0 1 Auto【PLU】Function 2: Enable in PLU mode; 3: Enable in all mode 0: Disable 255 Digit number for auto【PLU】 0~7 0 1 1~7:Auto【PLU】after digtals number inputted 256 Pre-Print Function 0~1 0: Disable; 1: Enable 1 1 Need Admin Password In 0: Normal; +1: Sale; +2: Prog 0 1 260 0~31 Certain Mode +4: Account; +8:【Drawer】; +16: Unit Price 0: Normal By-Weight PLU Forbidden in 261 0 1 +1: Batch Print, Certain Mode 0~15 +2:PrePack, By-Count PLU Forbidden in +4:Lock PLU, 262 0 1 Certain Mode +8:Auto Print Call PLU automatically in 0~99999 In idle status, device will call specified PLU 0 1 263 Idle status 99 automatically AUTO MODE transaction +1: Batch Print; +2: Prepack; 264 0~15 0 1 record as “Auto”, not “Sale” +4: Lock PLU; +8: Auto Print 265 Date Print Mode:Month 0~1 0: Digits; 1: Two Characters 0 1 266 Date Display Mode 0~1 0: Default; 1: Using Spec104 and 265 0 1 267 Fast Switch with Weight Unit 0~1 0: Default; 1: Forbidden Non-Standard 0 1 268 Auto Tare Lock 0~1 0: Default; 1: Auto Lock 1 1 269 Print Forbidden 0~1 1: Forbidden Print Model 0 1 0: Disable; 1: Enable if No PLU; 270 Weight Display Hidden 0~2 0 1 2: Enable if No Unit Price 271 Auto Upgrade 0~1 0: Disable; 1: Enable 0 1 0: Mid-Track; 272 Filter Mode 0~2 1: Multi-Average; 0 1 2: Suited-Average 0~99999 999999 274 Maximum PLU Number 0 Means no limit 1 99 4 275 Uniscribe Script 0~2 0: Disable, 1: RTL in LTR, 2: LTR in RTL 0 1 0: Normal; 1: Batch Print; 2: PrePack; 3: Lock 0 1 277 Default Working Mode 0~2 PLU; 4: Auto Print. 278 Hangup Bill Print Format 0~99 0: default; 1~99: specified print format 0 1 0: Forbidden; 1: Only hangup bill can be load once; 279 Hangup and Loadback 0~3 0 1 2: Only hangup bill can be load, no times limit; 3: All bill can be load 280 Salesman authorization 0~1 0: Forbidden; 1: Enable 0 1 282 Payment Operation Forbidden 0~63 0: all enable, 1~63: Please use software 0 1 84 No. Content 283 Record of Unconfirmed Data 287 288 289 290 291 292 293 non-VIP Discount Off VIP Default Discount Off Other Transaction Print Format Log Text 1 Log Text 2 Log Text 3 Log Text 4 Range Remarks Default Permission 0: Disable; 1: Record Priced Operation; 0~2 1 1 2: Record Priced/Weighted Operation 0~99 Percent-Off 0 1 0~99 0:Same as Spec287, 1~99: Specified Percent Off 0 1 0~99 0: Default; 1~99: Specified Pritn Format 0 1 0~14 0~14 0~14 0~14 0 0 0 0 1 1 1 1 0 1 0 0 1 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 1 6 7 1 1 1 1 1 0 0 (Need Special Firmware Version) 0: Blank; 1: PLU Name; 2~8: PLU Text1-7; 9: Item Code; 10: Index Barcode; 11~14: Custom Info 1~4 0: Auto Clear Custom Info1~4; 294 Keep Custom Info 0~15 +1:Keep Custom Info 1; +2:Keep Custom Info 2 +4:Keep Custom Info 3; +8:Keep Custom Info 4 297 Second Currency Exchange xxx Please use software 298 Second Currency Decimal Dot 0~5 Decimal dot position 0: Default; 1: desk scale; 299 Default stable arithmetic 0~3 2: platform scale; 3 hanging scale 0: Forbidden 300 Item Service Fee 0~2 1: Allowed, not collect total percent again 1: Allow, collect total percent again Item Service Fee: Default 0: Unit price mode; 1: Total price mode; 301 0~2 Method 2: Percent mode 0: Manual call, manual input price 1: Manual call, manual input percent Total Service Fee: Input 2: Manual call, take auto price 302 0~5 Method 3: Manual call, take auto percent 4: Auto call, take auto price 5: Auto call, take auto percent Under price mode, auto account according to Total Service Fee: Auto 0~ 303 price decimal point collect based number 9999999 Under pecent mode: unit is ‱ Service Fee: Percent 0: Based on price before tax 304 0~1 Collection based Number 1: Based on price after tax 0: No global tax rate 1: Default is exclude Tax with Excluded Rate 305 Tax Sort of Service Fee 0~3 2: Default is include Tax with Excluded Rate 3: Defaultx with included Rate 306 Tax Rate of Service Fee (‱)0~9999 0.01% tax rate, for 17%, need input 1700 307 Service Fee Permission 0~1 0: Forbidden, 1: Allowed 308 Service Fee Re-Input 0~1 0: Forbidden, 1: Allowed 340 Dot matrix LCD’s contrast 0~7 Do not change these settings. 341 Dot matrix LCD’s brightness 0~31 (PTR, parameters setting for network printer) 0 means print according to bill 1 format (once 350 PTR: Item print format 0~99 using bill 1 format, the barcode format and signals are all according to bill 1) 85 No. 351 352 353 354 355 356 357 358 359 360 361 362 363 364 365 366 367 368 369 370 371 372 373 374 375 376 377 378 379 400 401 Content PTR: Item barcode format Range Remarks 0~99 0~ PTR: Item barcode flag 9999999 PTR: Item print Times 0~99 PTR: Item print Reverse 0~1 0: No Reverse, 1: Print 180°Reversed 0 means print according to bill 1 format (once PTR: Sum Print Format 0~99 using bill 1 format, the barcode format and signals are all according to bill 1) PTR: Sum Barcode Format 0~99 0~ PTR: Sum Barcode Flag 9999999 PTR: Sum Item Print Times 0~99 PTR: Sum Item Print Rol 0~1 0: No Reverse, 1: Print 180°Reversed 0: Disable 1: Enable, wait till printing finished PTR: network print function 0~3 2: Enable, wait till printing started 3: Enable, wait till data sending finished 0: No operation 1: Online/offline clew 2: Online/offline clew, alarm when there is no PTR: printer status clew 0~3 rating printing 3: Online/offline clew, error when there is no rating printing PTR: rating number for 0~20 Alarm or error if less than rating number printer PTR: check interval 0~65535 Unit: second, default for 10s 0~255 0~255 PTR’s IP: No.1 0~255 0~255 0~255 0~255 PTR’s IP: No.2 0~255 0~255 0~255 0~255 PTR’s IP: No.3 0~255 0~255 PTR: Server Socket 0~65535 Do not change such setting unless there are PTR: Client Socket 0~65535 expert! Irrelevant change will make the network PTR: UDP Local Socket 0~65535 printer do not work PTR: UDP Remote Socket 0~65535 PTR: Print speed decrease 0~99 Reduced % of paper feed speed PTR: Paper Type 0~1 0: Plain Paper, 1: Gap Paper. Default Permission 0 0 0 0 1 0 1 1 0 0 0 0 0 0 1 0 1 1 1 1 1 1 0 1 0 0 0 0 0 0 0 0 0 0 0 0 0 33591 33592 33593 33594 0 0 1 0 0 0 0 0 0 0 0 0 0 0 0 1 1 1 1 1 0 86 No. Content Range Remarks Default Permission PTR: Gray Level of Gap 0 402 0~9 0 is lightest, 9 is darkest. The print color lighter, 7 Paper the damage to print header smaller. Suggest PTR: Gray Level of Plain 403 0~9 users use lighter grey level. 7 0 Paper PTR: Plain Paper: Interval of 404 0~99 0 0 Each Print Set the unit of number is mm. 0 means use default set PTR: Plain Paper: Cut-off 405 0~99 0 0 Position Unit of setting number is dot. PTR: Plain Paper: Pre-feed 0 0 406 0~1999 Device is reverse feed if number > 1000 Distance 407 PTR: Paper width 0~99 0 0 408 PTR: Default font 0~2 1 1 Continuously print appointed time will enter PTR: Printer over-heat 1 409 0~30 over-heat protect, Please don’t amend them 0 protect without the guidance of professionals. Hardware properties. Please don’t amend them 410 PTR: Feed Sensor Position 0~255 180 1 without the guidance of professionals. PTR: Point numbers for 411 narrow bar in barcode 0~9 0 1 0 for default set, Please don’t amend them printing without the guidance of professionals. PTR: Point numbers for wide 412 0~19 0 1 bar in barcode printing PTR: Readable character 413 0~2 0 1 fonts in barcode printing 415 PTR: Auto new line mode 0~1 0: One line mode; 1: Auto new line mode 0 1 PTR: ITF25 barcode frame 0: No frame; 1: Up and Down frame; 1 1 416 0~2 2: Around frame mode PTR: ITF25 barcode frame 417 0~31 Frame dots 8 1 width PTR: ITF25 barcode left and 418 0~31 Left and right blank dots 20 1 right blank width Unit of setting number is dot. PTR: Gap Paper: Pre-feed 0 0 419 0~1999 Device is reverse feed if number > 1000 Distance 420 PTR: Ignore PBS Sensor 0~1 Use to force remove error E6.12 0 1 421 PTR: Ignore PDS Sensor 0~1 Use to force remove error E6.11 0 1 422 PTR: Ignore PPS Sensor 0~1 Use to force remove error E6.14 0 1 450 PDF417: Checksum Level 0~9 0~8: Fix level; 9: System default level 9 1 451 PDF417: Columns Number 0~30 0: Auto sizing, 1~30: Fix number 0 1 452 PDF417: Rows Number 0~90 0~2: Auto sizing, 3~90: Fix number 0 1 453 PDF417: Bar Width 0~6 0: Default 3 0 1 454 PDF417: Bar Height 0~18 0: Default 6 0 1 455 QR: Check Level 0~3 1 1 456 QR: Version 0~31 QR Minimum Version 0 1 457 QR: Bar Size 0~6 0: Default=3 0 1 480 Custom Version Reserved ~499 Spec 87 7.3 Definitions of String data paremeters Number 0 1 2 3 4 5 6 7 8 9 10 11 12 13 Hint Text content Default Print ShopN Store Name Header center ScaleN Device Name Not use MnyPre Prefix of Money Unit MnySuf Suffix of Money Unit Strg-1 Bill text 1 Header center Strg-2 Bill text 2 Header left Strg-3 Bill text 3 Header center Strg-4 Bill text 4 Header left Strg-5 Bill text 5 End center Strg-6 Bill text 6 End left Strg-7 Bill text 7 End center Strg-8 Bill text 8 End left SpSt-1 Special text 1 Reserved SpSt-2 Special text 2 Reserved Number 14 15 16 17 18 19 20 21 22 23 24 25 26 27 Hint Ind-MK W-SSID W-PASS SpSt-6 SpSt-7 Domain Cstr-1 Cstr-2 Cstr-3 Cstr-4 Cstr-5 Cstr-6 Cstr-7 Cstr-8 Text content Default Print Industry Mark Industry Mark WiFiSSID Wireless SSID WiFi Password Wireless Password Special text 6 Reserved Special text 7 Reserved Special text 8 Reserved Custom Text 1 Custom Text 2 Custom Text 3 Custom Text 4 Custom Text 5 Custom Text 6 Custom Text 7 Custom Text 8 7.4 Definitions of Shortcut Function Key 1 Number:0 2 Number:1 3 Number:2 4 Number:3 5 Number:4 6 Number:5 7 Number:6 8 Number:7 9 Number:8 10 Number:9 11 Number:00 12 Clear 13 Cancel 14 Accu/Confirm 15 Cash/Print 16 PLU 17 F-Prog 18 V1 19 V2 20 V3 21 V4 22 Amend 23 × 24 Feed 25 SetZero 26 SetTare 27 Sale 28 Prog 29 Account 30 Time 31 -% 32 -Num 33 @Price 34 TSale 35 CashBox 38 Manual Weight 39 Paper Type 40 Pre/Re Print 41 Shift 44 Print2 45 CCard 46 MoveDot 47 U.W. Sample 48 Weight Accu 49 Division 50 UnitChange 51 Lock Tare 52 Auto Mode 53 Normal Mode 54 Batch Mode 55 PrePack Mode 56 LockPLU Mode 57 AutoPrint Mode 58 Service Fee 59 ←V→ 60 Mode 62 On/Off 63 66 VIP Custom Info 1 77 67 Other Transactions 76 PayOther-0 64 Custom Info 2 78 PayOther-1 65 PayOther-2 Custom Info 3 79 Custom Info 4 88
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
advertisement