null  null
Bar Code Printing Scale
Cash Register Scale
Cash Register Indicator
User Manual
2017.4
V3.04A
Preface
Thank you for use the product. Before you start to use this product, please be sure you have read the content
in the Preface and follow these guidelines.
Notice
 Make sure the electric plugs and wires are all properly connected, and use the 3-cell electric wire only. If
an extension-board is used, the outlet of the extension-board is also 3-cell. Make sure the earth wire is
properly connected to the earth in order to prevent the leakage of electricity.
 Don’t touch the electric plug with wet hand, in case of electric shock.
 Don’t lean your body on the scale to avoid damaging the load cell.
 Don’t impact the scale or shock the scale with heavy goods, in case of damaging the load cell. When
weighing, don’t exceed the maximum weighing range
 Don’t get the product rained or washed by water; If there is some water on the product by inadvertence,
please wipe it clean with a dry cloth; If the scale doesn’t work normally, please send the scale to our
distributor as soon as possible. We shall do our best to service you.
 Don’t put the scale in the places which are ultimately cold, hot or wet. These working conditions may make
the product not work normally or damage the product.
 Don’t use organic chemistry solutions to wipe the surface and the panel of the product.
 Don’t try to take the scale apart and repair the scale by non-professonal staff.
 Don’t put your hands into the product through the place where the printer spins out. It may cause electric
shock with 110V/220V electricity.
 Cut the connection between the scale and AC electricity when taking the scale apart under the guidance of
professional staff from our company.
 Don’t try to disassembly the switch power inside of the scale. Because it takes a long time to discharge the
high voltage capacitance, and it’s very dangerous to disassembly the switch power when the high voltage
capacitance is not fully discharged.
 Strongly recommend users to use thermal paper sold by our company. The scale can have a longer
life if working with thermal paper sold by our company because we have done a lot of experiments
and optimizations on the our thermal paper. On contrary, the life span of the printer may get
shortened if the printer works with the thermal paper, which is likely to deposit or leave carbon
deposits.
 Thermal header is a precise instrument. Don’t touch it with fingers or sharp goods. Always use the
accessary cleaning tools to keep the header clean.
i
Guide to Read
 Please go to page 8 Thermal Printer and learn the method to install paper and notices for users.
 Please read page 2 General Functions, Configuration and Using Index carefully first in order to know
about the performance of the scale.
 Please read page 16 Fast Prog carefully first , and learn frequently used programme operations of the scale.
 For ordinary users, please first read page 21, the two chapters Transfer and Lock of PLU (page 21) and
Manual Goods Sale (page 22) in the Sale Operations, and learn general sale operations of the scale.
 For ordinary users, read page 64 Account Operations, get to know how to print the report forms and delete
the records. And read Operations of Sale Buffers in page 31 to learn how to look over the recent sale
records.
 For advanced users, read the rest of Sale Operations,and learn auto mode and other functions.
 For professional users, such as managers in big supermarket, should continue reading the rest of the
instruction.
 When error warning shows up, check Reference Table For Errors and Its Instructions in page 70 .
Abbreviations and Glossary
 PLU: Price of LookUp. It’s a cell which contains the information of goods
 Weight PLU, Count PLU: By-weight PLU, By-Count PLU.
 Dept., Class: Dept. is short for department, is the largest category in sales statistics. Class is the second
largest category in sales statistics.
 U.Price, T.Price: Unit Price and Total Price.
 Single T.Price, Sum T.Price: Single T. Price means the price of certain goods, while Sum T. Price means the
price of total trade.
 Prog, F-Prog: Name of keys, Short for programme and Fast Programme.
 T-Sale: Temporarily Sale. Trade goods is not an exist PLU. Sell them by input a manual price. And the
scale will think the goods as PLU 1 (Weight), or 2 (Count).
 Spec: Specification. It is made up of many number parameters, which determines the operation flow and
working state.
 TMSet: Working parameters setting.
 DTSet: Working date setting.
 Amount: The quantity of the goods, weight or count. It means weight (kg, lb) for weight PLU and count
(pcs) for count PLU
 【Text】: Mark the Text as a key name.
 〖Text〗: Mark the Text as a display indication name.
ii
Menu
Preface ........................................................................................................................... i Notice .......................................................................................................................... i Guide to Read ............................................................................................................. ii Abbreviations and Glossary ....................................................................................... ii Menu ............................................................................................................................ iii Examples Menu ........................................................................................................ viii 1 Components of Barcode Print Scale ................................................................... 1 1.1 Check Accessories ................................................................................................ 1 1.2 Keyboard .............................................................................................................. 1 1.2.1 The Original Overlay of the Keyboard ..................................................................................................... 1 1.2.2 Instructions for Keys................................................................................................................................. 2 1.2.3 Instruments for Keys in Function Area ..................................................................................................... 2 1.2.4 Character Input Instructions...................................................................................................................... 4 1.3 Display Panel ........................................................................................................ 5 1.3.1 Sketch Map of Display Panel.................................................................................................................... 5 1.3.2 Indication Signs ........................................................................................................................................ 6 1.3.3 Expression of Characters .......................................................................................................................... 7 1.3.4 Dot Matrix Display ................................................................................................................................... 7 1.4 Specifications ....................................................................................................... 7 1.5 Thermal Printer (bar code label printing scale only) ........................................... 8 1.5.1 Install Gap Paper....................................................................................................................................... 8 1.5.2 Gap Paper Mounts Recycle ...................................................................................................................... 9 1.5.3 Install Plain Paper ..................................................................................................................................... 9 1.5.4 Operations Concerning Paper ................................................................................................................. 10 1.5.5 Abnormity of Gap Paper Print ................................................................................................................ 10 1.5.6 Specification for printing interface ..................................................................................................... 10 2 General Functions, Configuration and Using Index ....................................... 11 iii
2.1 General functions ............................................................................................... 11 2.2 Setting of Print Format ....................................................................................... 11 2.3 Barcode printing and scanning ........................................................................... 12 2.4 Measure Functions ............................................................................................. 12 2.5 Sale Functions .................................................................................................... 13 2.6 Salesman Function ............................................................................................. 14 2.7 Report Functions ................................................................................................ 14 2.8 Sales details ........................................................................................................ 14 2.9 Network function ................................................................................................ 14 2.10 Ethernet Thermal Printer .................................................................................. 15 2.11 Software use ..................................................................................................... 15 3 Fast Prog .............................................................................................................. 16 3.1 Fast-Prog of PLU................................................................................................ 16 3.2 Fast-Prog of Shortcut Key for PLU.................................................................... 18 3.3 Fast-Prog of Spec Parameters ............................................................................ 19 3.4 Fast-Prog of Unit price ....................................................................................... 20 4 Sale Operations ................................................................................................... 21 4.1 Transfer and Lock of PLU .................................................................................. 21 4.1.1 Transfer by Using PLU Number ............................................................................................................. 21 4.1.2 Tranfer by Using PLU Shortcut Keys ..................................................................................................... 21 4.1.3 Transfer Temporary Weight PLU ............................................................................................................ 22 4.1.4 Transfer Temporary Count PLU ............................................................................................................. 22 4.2 Manual Goods Sale ............................................................................................ 22 4.2.1 Sale and Print of Single Weight Goods ................................................................................................... 22 4.2.2 Sale and Print of Single Count Goods .................................................................................................... 23 iv
4.2.3 No Weigh Sale for Weight Goods ........................................................................................................... 23 4.2.4 Sale and Print for Different Kinds of Goods (No Cashing Mode) .......................................................... 24 4.2.5 Sale and Print for Different Kinds of Goods (Cashing Mode, Input Payment) ...................................... 24 4.2.6 Sale and Print for Different Kinds of Goods (Cashing Mode, Payment Equal to Price) ........................ 25 4.3 Discount Operations ........................................................................................... 25 4.3.1 U.Price Discount ..................................................................................................................................... 25 4.3.2 T.Price Discount...................................................................................................................................... 26 4.3.3 ±% price .................................................................................................................................................. 26 4.3.4 Auto Discount ......................................................................................................................................... 27 4.3.5 Unit Conversion of Temporary U.Price .................................................................................................. 28 4.4 Setting and Lock of Tare .................................................................................... 28 4.4.1 Weight Tare ............................................................................................................................................. 28 4.4.2 Number Tare ........................................................................................................................................... 28 4.4.3 Lock and Unlock of Tare ........................................................................................................................ 29 4.5 Special sale mode ............................................................................................... 29 4.5.1 Enter and Exit of Special sale Mode ....................................................................................................... 29 4.5.2 Sale under batch print mode ................................................................................................................... 30 4.5.3 Sale under prepack mode (only for weight PLU) ................................................................................... 30 4.5.4 Sale under Lock PLU mode .................................................................................................................... 31 4.5.5 Auto print mode (only for weight PLU) ................................................................................................. 31 4.6 Operations of Sale Buffers ................................................................................. 31 4.6.1 Switch of Sale Buffers ............................................................................................................................ 31 4.6.2 Cancel Sale Data in Sale Buffers ............................................................................................................ 32 4.7 Salesman and Waiter .......................................................................................... 33 4.7.1 Personnel Information ............................................................................................................................ 33 4.7.2 Salesman Function .................................................................................................................................. 33 4.7.3 Waiter Function....................................................................................................................................... 33 4.8 Inquiry of Sale Records and Markers of Returns of Goods ............................... 33 4.9 Manual Weight ................................................................................................... 34 4.9.1 Manual Sale of Manual Weight Entry..................................................................................................... 34 4.10 Bar code printing and scanning ........................................................................ 34 4.10.1 Exterior bar code................................................................................................................................... 34 v
4.10.2 Interior bar code .................................................................................................................................... 35 5 Programme Operations...................................................................................... 36 5.1 Please Read this Part First .................................................................................. 36 5.2 Basic Operations in Programme Interface ......................................................... 36 5.2.1 Tree-shaped Design of Edit Steps ........................................................................................................... 36 5.2.2 Frequently-used Keys in Prog Interfaces ................................................................................................ 37 5.2.3 List of Programme Interface ................................................................................................................... 38 5.3 The Edit of All Parts in TMSet ........................................................................... 44 5.3.1 Time Programme .................................................................................................................................... 44 5.3.2 Programme of Spec Parameters .............................................................................................................. 44 5.3.3 Programme of Text Parameters ............................................................................................................... 45 5.3.4 Programme of PLU Shortcut Keys ......................................................................................................... 45 5.3.5 Programme of Fuction Shortcut Keys .................................................................................................... 46 5.4 The Edit of All Parts in DTSet ........................................................................... 46 5.4.1 Department Programme .......................................................................................................................... 46 5.4.2 Class Programme .................................................................................................................................... 47 5.4.3 PLU Programme ..................................................................................................................................... 47 5.4.4 Unit Programme...................................................................................................................................... 49 5.4.5 Barcode Programme ............................................................................................................................... 50 5.4.6 Print Formats Programme ....................................................................................................................... 53 5.4.7 Salesman Programme ............................................................................................................................. 56 5.5 Assistant Data Programme ................................................................................. 57 5.5.1 Steps Select of PLU Programme ............................................................................................................ 57 5.5.2 Steps Select of PLU Fast Programme ..................................................................................................... 57 5.5.3 Delete Sale Data ..................................................................................................................................... 58 5.6 Communication and Data Update ...................................................................... 59 5.6.1 Operations of files in USB flash Disk. ................................................................................................... 59 5.6.2 Ethernet Monitor Interface...................................................................................................................... 60 5.6.3 RS232 Communications ......................................................................................................................... 61 5.7 Hardware Assistant ............................................................................................. 61 5.7.1 Validate Code .......................................................................................................................................... 61 5.7.2 Password ................................................................................................................................................. 61 vi
5.7.3 Recover Factory Default Setting............................................................................................................. 62 6 Account Operations ............................................................................................ 64 6.1 List of Account Interfaces .................................................................................. 64 6.2 Operations of Printing Report ............................................................................ 64 6.2.1 Print Total Report.................................................................................................................................... 64 6.2.2 Print Department Report ......................................................................................................................... 65 6.2.3 Print Class Report ................................................................................................................................... 65 6.2.4 Print PLU Report .................................................................................................................................... 65 6.3 Clear Report Information ................................................................................... 66 6.3.1 Clear Report Information Manually ....................................................................................................... 66 6.3.2 Clear All Reports and Records Information............................................................................................ 66 6.3.3 Clear stock information........................................................................................................................ 66 6.3.4 Reposition SID information ................................................................................................................. 67 6.4 Stock Management ............................................................................................. 67 6.4.1 Stock Management ................................................................................................................................. 67 6.4.2 Stcok Print .............................................................................................................................................. 67 6.4.3 Stock Audit ............................................................................................................................................ 68 6.5 List Print ............................................................................................................. 68 6.5.1 Sale Log ................................................................................................................................................. 68 6.5.2 List Print ................................................................................................................................................ 68 7 Appendix.............................................................................................................. 70 7.1 Reference Table For Errors and Its Instructions................................................. 70 7.2 Definitions of Spec data parameters................................................................... 73 7.3 Definitions of String data paremeters................................................................. 88 7.4 Definitions of Shortcut Function Key ................................................................ 88 vii
Examples Menu
Example 3-1 Fast-Prog of PLU ............................................................................................................................... 16 Example 3-2 Fast-Prog of Shortcut Key for PLU. Amend a shortcut key. .............................................................. 18 Example 3-3 Fast-Prog of Shortcut Key for PLU. Amend two or more shortcut keys............................................ 18 Example 3-4 Fast-Prog of Spec Parameters ............................................................................................................ 19 Example 3-5 Fast-Prog of unit price (Spec083=1) .................................................................................................. 20 Example 3-6 Fast-Prog of unit price (Spec083=2) .................................................................................................. 20 Example 4-1 Use PLU Number to Transfer Weight PLU ........................................................................................ 21 Example 4-2 Use PLU Number to Transfer Count PLU ......................................................................................... 21 Example 4-3 Use PLU Shortcut Keys to Transfer Weight PLU .............................................................................. 21 Example 4-4 Use PLU Shortcut Keys to Transfer Count PLU ................................................................................ 21 Example 4-5 Transfer Temporary Weight PLU ....................................................................................................... 22 Example 4-6 Transfer Temporary Weight PLU with a Unit Conversion of the U.Price. ......................................... 22 Example 4-7 Temporary PLU number is decided by Spec094(default 9999998) ................................................... 22 Example 4-8 Sale for Single Weight goods ............................................................................................................. 22 Example 4-9 Sale and Print for Single Count goods ............................................................................................... 23 Example 4-10 No Weigh Sale for Weight PLU ....................................................................................................... 23 Example 4-11 Sale and Print for Different Kinds of Goods (No Cashing Mode) ................................................... 24 Example 4-12 Sale and Print for Different Kinds of Goods (Cashing Mode, Input Payment) ................................ 24 Example 4-13 Sale and Print for Different Kinds of Goods (Cashing Mode, Payment Equal to Price).................. 25 Example 4-14 Execute Discount in Subtraction ...................................................................................................... 25 Example 4-15 Execute Discount at a Fixed Number ............................................................................................... 25 Example 4-16 Input data to execute ±% price ......................................................................................................... 26 Example 4-17 Enterinterface and execute ±%price ................................................................................................. 26 Example 4-18 Directly execute default ±%price(Spec114) ..................................................................................... 27 Example 4-19 Auto Discount................................................................................................................................... 27 Example 4-20 Unit Conversion of Temporary U.Price............................................................................................ 28 Example 4-21 Weight Tare ...................................................................................................................................... 28 Example 4-22 Number Tare ..................................................................................................................................... 28 Example 4-23 Tare Lock and Unlock ...................................................................................................................... 29 viii
Example 4-24 Single key select of sale mode ......................................................................................................... 29 Example 4-25 Interface select sale mode ................................................................................................................ 29 Example 4-26 Batch Print mode .............................................................................................................................. 30 Example 4-27 Prepack mode(only for weight PLU) ............................................................................................... 30 Example 4-28 Switch of Sale Buffers...................................................................................................................... 31 Example 4-29 Clear All Data in Current Sale Buffers ............................................................................................. 32 Example 4-30 Clear One Goods in Current Sale Buffer.......................................................................................... 32 Example 4-31 Inquiry of Sale Records and Markers of Returns of Goods ............................................................. 33 Example 4-32 Manual Sale of Manual Weight Entry .............................................................................................. 34 Example 5-1 Time Programme ................................................................................................................................ 44 Example 5-2 Programme of Spec parameters.......................................................................................................... 44 Example 5-3 Programme of Text Parameters .......................................................................................................... 45 Example 5-4 Programme of PLU Shortcut Keys..................................................................................................... 45 Example 5-5 Programme of Fuction Shortcut Keys ................................................................................................ 46 Example 5-6 Department Programme ..................................................................................................................... 46 Example 5-7 Class Programme ............................................................................................................................... 47 Example 5-8 PLU Programme................................................................................................................................. 48 Example 5-9 Unit Programme ................................................................................................................................. 50 Example 5-10 Barcode Programme ......................................................................................................................... 50 Example 5-11 Salesman Programme ....................................................................................................................... 56 Example 5-12 Steps Select of PLU Programme ...................................................................................................... 57 Example 5-13 Steps Select of PLU Fast Programme .............................................................................................. 57 Example 5-14 Delete PLU20~30 ........................................................................................................................... 58 Example 5-13 Load Files in USB Flash Disk .......................................................................................................... 59 Example 5-14 Save working data to Files in USB Flash Disk ................................................................................ 59 Example 5-15 Save sale list to Files in USB Flash Disk ......................................................................................... 60 Example 5-16 Enter Ethernet Monitor Interface ..................................................................................................... 60 Example 5-17 Process of Amending Passwords ...................................................................................................... 62 Example 5-18 Process of Amending Passwords ...................................................................................................... 62 Example 6-1 Print Daily Reports of Today and Yesterday ...................................................................................... 65 Example 6-2 Print PLU Daily Reports with the Numbers from 10 to 20 ................................ 错误!未定义书签。 ix
Example 6-3 Clear Information in Manual Report .................................................................................................. 66 Example 6-4 Clear All Reports and Records Information ....................................................................................... 66 Example 6-5 Clear stock information ...................................................................................................................... 66 Example 6-6 Clear manual report ............................................................................................................................ 67 Example 6-7 Print stock Reports with the Numbers from 10 to 20 ......................................................................... 67 Example 6-8 Amend PLU10 stock to 100 ............................................................................................................... 68 Example 6-9 Intraday List Print .............................................................................................................................. 68 Example 6-10 Appointed Time Period List Print..................................................................................................... 69 x
1 Components of Barcode Print Scale
1.1 Check Accessories
 One scale or indicator;
 One tray(scale only);
 One display pole (pole type only);
 One pack of screws used to fix the pole (pole scale only);
 One copy User Manual (this book);
 One CD for PC software TM-xA Management Software
 One overlay for shortcut PLU;
 One power plug;
1.2 Keyboard
1.2.1 The Original Overlay of the Keyboard
Picture 1-1 Sketch Map of Keyboard Function for barcode label printing scale (Pole)
7
8
9
4
5
6
1
2
3
X
0 00
Picture 1-2 Sketch Map of Keyboard Function for barcode label printing scale (Bench)
Picture 1-3 Sketch Map of Keyboard Function for cash register scale
1
Picture 1-4 Sketch Map of Keyboard Function for cash register indicator
The graph above shows the original definitions. Some buttons on the left top area are marked with numbers,
which are serial number for the shortcut keys. In this text, 【SCxx】 is used to represent shortcut keys. For
example, 【SC1】 represents the first key on the left top marked with number 1. 【SCxx】on the left side are PLU
preset shortcut keys and can be set to represent one certain key if user requests. When editing the text, 【SCxx】
are function keys and character keys for the input of letters. Please refer to chapter 1.2.4. 【SCxx】on the right side
are preset shortcut keys for additional functions . The presetting is shown in the graph. And it’s not available for
user to change the setting of function keys now.
1.2.2 Instructions for Keys
When you press right keys, the scale would beep shortly to show the operation is right.
When you press wrong keys, the scale will beep in 1 long sound and 2 short sounds. The composite beeps
mean the failure in operation process or errors in pressing keys. If operaton process fails, there will be Ex.xx
displayed on the screen (e.g., E1.01 means programme data is invalid.).
It may take 4 seconds to press one key in the operation which needs to Long Press the key without releasing
it. During the period you will hear 2 beeps. The first beep sounds as soon as you press the key while the other one
sounds 4 seconds after pressing the key.
In some【F-Prog】+【Other key】 operations, users should first press 【F-Prog】 without releasing and press
the 【Other key】 in order to complete the operation.
In the following instruction: 【Key1】
【Key2】 means the operation that press 【Key 1】first and release it,
then perss【Key 2】and release it. 【Key1】+【Key2】means the operation that press 【Key1】 and 【Key2】
at the same time. When users do it , press 【Key1】 first, and press 【Key2】 without releasing 【Key1】 .
1.2.3 Instruments for Keys in Function Area
Picture 1-1
shows the default setting of keys in the function area. According to customer’s requests, default
setting may be different. And the specific setting will be on the overlay:
 【Sale】: Enter sale mode and execute the operation of goods sale.
 【Prog】: Enter programme mode and programme on parameters, PLU, print formats, time and so on.
 【Account】: Enter Account mode to inquire about deals data or print reports and so on.
 【Time】: Display current time and return to the previous interface when you press it again.
2
 【Mode】: Switch in Sale, Prog, Account Mode.
 【Tare】: Set current weight as tare or appoint certain data as tare (When there is a number in input window,
number tare is the priority.). Pressing 【Tare】 for a long time without releasing, system would enter
【Tare Lock】. And do it again to exit this state.
 【Zero】: Clear current weight and reset zero within allowed range. If not within allowed range, set zero
would fail.
 【Shift】: Shife key used for extending PLU shortcut key, and switching case sensitivity in text input
interface. When current input number is decimal (tare, weight, U.Price, T.Price) , long press 【Shift】or
press 【F-Prog】+【Shift】 would change the position of decimal point.
 【Auto Mode】 【Pre-Pack Mode】, 【Batch-Pint mode】, 【Auto print】
【Lock PLU】: Switch ordinary
mode with pther sale mode. Users can long-press this key to enter sale mode select if current sale buffer
is empty.
 【Manual Weight】:Key for manual entry of weight. “ManWT” will add before weight data while printing.
Open this functions in Spec if user needs it.
 【Paper Type】: Long Press it switch paper between gap thermal paper and plain thermal paper.
 【Re-print】: Repeat last print in current buffer (Repeated print data would not be stored in deal records as
sale record.). This function can be forbidden in Spec.
 【Feed】: Roll the gap thermal paper and plain thermal paper. Unprinted buffer data will be cleared in the
process of feed.
 【-%】【±%】: Discount in percentage, PDis  P(1 
Input
) . Please notice that input is decimal and pay
100
extra attention to the position of decimal point. Discount is 5% off while input is 500, if there are two
zeroes after decimal point. And input should be 5000, If there are three zeroes. You can refer to Spec113,
Spec114 for detailed explaination.
 【-Num】: Discount in subtraction. PDis  P  Input . Input is also decimal.
 【[email protected]】【@Price】:: Discount to a fixed price. PDis  Input . Input is also decimal. You can also use this
key to save the discounted price to PLU directly, please refer to Spec083
 【T-Sale】: Set input number as Unit Price and set a temporary PLU. You can amend the temporary weight
PLU’s unit in Spec, for example, if the temporary weight PLU’s unit is 500g, but the scaleunit is kg, then
system will antomatically conversion (multiply 2)
 【Drawer】: Open drawer besides normal operations.
 【CCard】or【Credit payment】: Obligate function
 【F-Prog】: Change some setting or values of PLU fastly in sale mode. It is always used for combination of
keys, which is similar as ‘Alt’ ‘Ctrl’ in PC keyboard. Please refer to process instructions to understand
the use of combination keys.
 【×】: Input count amount in count sale. Or do temporary count goods sale according to input U.Price.
 【Amend】: Amend deal data in sale interface and store amended data in programme interface.
3
 【←】【↑】
【↓】【→】: Switch among neighbouring steps and numbers in programme and account
interfaces.
 【V1】~【V4】: Activate corresponding sale buffers.
 【0】~【9】,【00】: Input corresponding numbers.
 【Back】: Delete the last digit input number.
 【PLU】: Transfer PLU datas using input numbers as serial numbers.
 【Cash/Print】: Check out in cash; calculate changes and print labels or receipts according to setting.
 【Cancel】: Clear data, cancel operations or go back to previous step.
 【Accu/Confirm】: Save accumulative deal data into activated sale buffer and other confirmation
operations.
1.2.4 Character Input Instructions
The key of function section remains the same when system enters letters input interface, while 【SC1】~
【SC63】 are used to input letters. In input process, definitions of keyboard are shown below:
 【Amend】: Confirm text input. Save and exit.
 【Cancel】: Cancel edited data and quit without saving.
 【Confirm】: Confirm the input in special IME (not used in pure English version).
 【End】: Input end character, and all characters after appointed position are deleted.
 【Delete】: Delete the character at the position where cursor is.
 【Insert】: Switch cover mode with insert mode. Cover mode is activated when cursor is constant on while
insert mode is activated when cursor is glittering.
 【IME】: Input method editor. Switch the input languages: En-1 (in small letters), En-2 (in big letters), Chs
(chinese code), Code (machine code).
 【Shift】: Switch En-1, En-2 in temporary state.
 【←】【→】: Move current editing position backwards or forwards.
 【0】~【9】 and【SC1】~【SC59】: Input characters or codes.
In the process of input text, meanings of four windows are shown below:
 The first window: Display current input mode: one of En-1, En-2, Chs and Code.
 The second window: Display the position of current editing letters in the text.
 The third window: Display current editing position and content of neighing letters. In En-1 or En-2 ASCII
mode is displayed while in Chs or Code Hex mode is displayed. Cover mode is activated when cursor
which shows the position is constant on, while insert mode is activated when cursor is glitter.
 The fourth window: Display current input content. In En-1 or En-2 the window displays nothing, and in
Code input machine code is displayed.
Switch 4 kinds of input languages by pressing switch keys. Input mode of each kind of input language is
shown below:
 En-1 small letter: Input numbers or ASCII characters. For the keys with ‘/’, input character is the one on
the left of ‘/’. Pressing【Shift】, next input character and only this one is under the rule of En-2 .
 En-2 capital letter: Input numbers or ASCII characters. For the keys with ‘/’, input character is the one on
4
the right of ‘/’. Pressing【Shift】, next input character and only this one is under the rule of En-1 .
 UTF8 (U version IME, for UTF8 font scale use only): UTF-8 input method, input Unicode to get the
characters, input different kinds of non-English language characters, please check code from UTF8
Test Editor Manual, after input Unicode, press【Confirm】to finish the input
 PY Chinese pinyin mode (E version IME, font scale use only): Input pinyin, and select chinese
character by【←】【→】, Press【Confirm】 to input a Chinese character. In pinyin mode, Press
【Space】to select SBC case symbol, Press 【Space】 twice to select English symbol.
 Chs Chinese ISN mode (E version IME, font scale use only): Input ISN code to select a Chinese character
or SBC case symbol.
 Code: Input machine code mode. Users can input ASCII, symbols in special IMEs. The system could
automatically distinguish the input content as ASCII, symbols in special IMEs. Machine codes of
each field can be found in following table.
Table 1-1 ASCII Code Table
0
0
1
2
3
4
5
6
7
8
9
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
*
:
J
Z
J
Z
+
;
K
[
k
{
,
<
L
\
l
|
.
= >
M N
] ^
m n
} ~
/
?
O
_
o
Non-print character
!
0 1
@ A
P Q
` a
p q
“
2
B
R
b
r
#
3
C
S
c
s
$
4
D
T
d
t
% &
5 6
E F
U V
E f
U v
‘
7
G
W
g
w
(
8
H
X
h
x
)
9
I
Y
i
y
Not used
1.3 Display Panel
1.3.1 Sketch Map of Display Panel
Picture 1-5 Display Overlay
5
Picture 1-6 Display Overlay with Dot-matrix Display
1.3.2 Indication Signs
 〖Zero〗: It’s on when weight is zero and stable.
 〖Stable〗: It’s on when weight is stable.
 〖Lock Tare〗: It’s on when tare is locked. Long press 【Tare】 would lock tare. Under this condition, tare
would not be cleared after the sale. Long press 【Tare】 again would exit lock tare.
 〖Lock PLU〗: It’s on when PLU is locked. Long press 【PLU】 would lock PLU. Under this condition,
former PLU sale state would remain the same after the sale. And it will last until new PLU is transferred.
Long press 【PLU】 again would exit lock PLU.
 〖Auto mode〗: It’s on in auto mode. When in auto mode, lock PLU will active. In this mode, pre-pack or
batch print is executed based on Spec078 and Spec079.
 〖Pre-pack〗same as 〖Auto mode〗
 〖Auto Print〗the light will on when in auto printing
 〖Manual Weight〗:It’s on when manual weight is displayed.
 〖Gap paper〗: It’s on when paper type is gap paper. If it’s off when paper type is plain paper.
 〖NET〗: It’s on when tare is set and net weight is displayed. Press 〖Fast Prog〗
〖Tare〗will display
gross weight
 〖Shift〗: Press 【Shift】 and it is on.
 〖Sale〗: It’s on in sale mode.
 〖Prog〗: It’s on in programme mode.
 〖Account〗: It’s on in account mode.
 〖Change〗: It’s on when the data in third window is displayed as cash change.
 〖U.Price〗: It’s on when the data in third window is displayed as goods U.Price.
 〖V1〗~〖V4〗: It’s on when there are buffers in V1~V4 records. And it’s glittering in edit mode.
 〖Discount〗: To display single means that current goods has been discounted in U.Price; To display total
means that current accumulative total has been discounted in T.Price
 〖Single〗: It’s on when total price of current goods is displayed in fourth window.
 〖Sum〗: It’s on when the sum total price of current sale buffers (V1~V4) is displayed in fourth window.
6
1.3.3 Expression of Characters
Picture 1-7 Number Characters 0~9
Picture 1-8 Characters A~M
Picture 1-9 Characters N~Z
Picture 1-10 Dash、underline, aboveline, three lineations of special symbols
 Dash of special symbols: the same as ‘-’ in ASCII.
 Underline of special symbols: Used to represent the characters which cannot be displayed in ASCII(the
symbols except 0~9, A~Z and ‘-’)
 Aboveline of special symbols: Used to represent extended characters. In Chinese edition, two aboveline
represent a Chinese character.
 Three lineations of special symbols: In calibrating processes, it’s used as a prompt to decide to enter
calibrating interface or standard interface.
1.3.4 Dot Matrix Display
5-windows scales have an additional 160×32 dot matrix LCD display. It displays time or ad-message or
accumulation record in idle mode; and displays PLU’s name in PLU mode.
1.4 Specifications
 Power supply: AC200V~240V, 47~53Hz
 Operation temperature: 0℃~40℃
 Conservation temperature: -20℃~70℃
 Operation humidity: 15%~85%RH
7
Capacity
Resolution
Division
Accuracy
6kg
3000
2g
III
15kg
3000
5g
III
30kg
3000
10g
III
1.5 Thermal Printer (bar code label printing scale only)
1.5.1 Install Gap Paper
Install process is as below: Left is drawer structure (08’s). Right is cover structure (12’s)
1.Open Upper door
1.Open side door
Picture 1-11 Open door of scale printer
Hook
Raise Fall
2.Raise the print head
2.Move hook in direction of arrow
Picture 1-12 Open press mouth
4.Rotate LIMIT
90 ,for paper
pass though
3.Rotate up LIMIT
4.Install
paper roll
3.Install
paper roll
Picture 1-13 Install paper roll
8
5. Paper get through
5.Paper get through
7.Roll paper
7. Roll Paper
6.Remove U Spring
6. Remove U Spring
Picture 1-14 Paper through
10.Adjust LIMIT height
9.Press down header
10.Adjust
LIMIT height
8.Sandwich paper by U spring
9.Close header
8. Sandwich paper
by U spring
Picture 1-15 Finish paper install
11.Cover door
12.Press【Feed】
12.Press【Feed】
11.Close door
Picture 1-16 Close door of scale printer
1.5.2 Gap Paper Mounts Recycle
Pull out spring
Picture 1-17 Gap paper mounts recycle
1.5.3 Install Plain Paper
Different from the way in installing gap paper shown in 1.5.1, U-shaped paper retaining spring is not needed
anymore. All you need to do is to put the paper into the paper sensor and let the tear part be outside.
9
1.5.4 Operations Concerning Paper
 【Paper Type】: Make sure the type of paper set is the same as the type used. When 〖Gap Paper〗is light
in the display, you should set to use gap paper. Otherwise you should set to use plain paper. If the type of
paper you set to use is different from the type currently used, please long press 【Paper Type】to change
the set.
 【Feed】: After installing the paper, press【Feed】. You can also press 【Feed】 to clear abnormities of the
printer and make paper roll for a certain length.
1.5.5 Abnormity of Gap Paper Print
Users of plain paper don’t do any adjustment for this.
Abnormity of printer parameters may happen when gap paper prints are unnormal, paper goes out
continuously, or printer can’ work after one paper is printed, printing parameter maybe have abnormity
Users need to check if paper type is right first. Then users could follow these operations below to eliminate
malfunctions:
 Install gap paper, and make the edge of gap paper not exceed print head. (Not block the paper-out sensor)
Picture 1-18 Paper-Out sensor
 Switch off the scale. Press the 【Feed】key then swith on the scale, hold this key until finished self checking
and go into work inteface
 Printer would roll out the paper at the length of 50mm. automatically
 After the paper is rolled out, malfunctions have been eliminated if without any warning. If alarm E7.10
means calibration abnormity, pls try again after confirming the sticker perper has been used.
 Then, press 【Feed】to print the test page
 Go to normal operation processes.
1.5.6 Specification for printing interface
Window
Sample
Tare
Weight/Count
E7.1x
If normal printing, this When mass
window is blank, if
printing, this
have error, will display window will
Specification
erro message, the
display the
mean for message pls
number rest
refer to Addenda 7.1 unprinted.
CHG/Unit Price
P1-02
Display present printing
doc and number. P1-01
means the 2nd page of
Doc 1. If total print 1
page, this window will
blank.
U.Weight/T.Weight
Print
When printing
display: Print
Not Printing wil
display blank.
10
2 General Functions, Configuration and Using Index
2.1 General functions
 The printer can store 5990 PLUs. (Can extend to 10000 PLUs)
 Users can use gap thermal paper (TM-xA Series) and plain thermal paper.
 The printer provides many kinds of price input and discount.
 The print provides reports print for different time periods and classifications
 Precision of measurement: business mode 1/6000 (1/7500 for 15kg), industrial mode 1/30000.
 Support network, use RS232 and U disc as tool of data transer, all data can set on the PC, then use these
interface to upload and download.
 Save sales details, can upload to PC through above interface
 5-windows scales have an additional 160×32 dot matrix LCD display.
2.2 Setting of Print Format
 Bar Code Printing Scale: Press【Paper Type】for 4 seconds to switch between gap paper and plain paper.
This key would amend Spec021.
 Bar Code Printing Scale: There are 9 kinds of default print formats. Please reference to Factory Default
Print Formats in page 53.table 5-5
 Bar Code Printing Scale: 58mm*40mm and 40mm*30mm gap paper, 58mm and 40mm width plain paper
are available in default print formats. When using different type of paper, please adjust the corresponding
Spec shown in the table below.
Paper type
Spec
Print type
Instructions
000
005
027
58mm*40mm
Label print
1
4
50
Default
gap paper
Receipt print
7
7
50
Not recommend
40mm*30mm
Label print
2
5
36
gap paper
Receipt print
8
8
36
58mm width
Label print
1
4
50
plain paper
Receipt print
7
7
50
40mm width
Label print
2
5
36
plain paper
Receipt print
8
8
36
Not recommend
 Cash Register Scale: Cash register scale preset support 55mm width plain paper, default using recept
printing format
 Print formats include label print and receipt print. If user needs custom print format, please use PC
software to change or contact with appointed after-service cencer.
 Don’t print bills while saling: amend Spec003 and Spec008 to 0. If some specific deals need to print bills,
please press 【Reprint】.
 To print a few copies of one bill, put the amount into Spec003 and Spec008.
11
 To print two different kinds of bills: set the type of bill 1 in Spec000~Spec009, and bill 2 in
Spec010~Spec019. Strongly suggest users contact with appointed after-service cencer
 Set grey level of gap thermal paper in Spec022.
 Set grey level of plain thermal paper in Spec023.
 Set plain thermal paper in Spec 025, the position for cut-off paper suggest Spec025 not less than 30
 You can set different kinds of print formats and barcode types for each PLU. You can check the details in
PLU parameters for print formats and barcode types. Set the value of these parameters to 0 if you choose
the system type.
 The procedures to confirm print format: take bill 1 as an example. If two or more goods are sold, print sum
bill and use Spec005 as print format. If only one good is sold, print the item bill. If sale PLU has been set
for a specific print format (not 0), system would use the print format. If no specific print format has been
set to sale PLU (The setting number is 0.), the print format would be Spec000.
2.3 Barcode printing and scanning
 Can print various kinds of bar code, 9 kinds of default barcode settings, details in page 52 Table 5-4
Factory Default Barcode.
 Can scan inner code and external code, details in page 34, the specification of Bar code printing and
scanning
 Barcodes can be divided by use into item barcodes and total barcodes, which are printed in item labels and
total labels respectively.
 Factory default barcodes support 5-digits total price and 6-digits total price. Please select the barcode
compatible with the POS
001
006
Spec
002
007
1
7
xx
xx00000
6
4
8
xx
xx0000
Flag Code
Using PLU
Item-Code
5
2
7
xx
xxyyyyy
6
5
8
xx
xxyyyy
No Flag Code
Using PLU
Item-Code
5
3
7
yyyyyyy
6
6
8
yyyyyy
Goods Code
Flag Code
Using PLU No.
Digits
of Price
5
Default
Suggestion
x…is the flag code which is reserved for
scale in POS system. User could define
0 as a MISC code for PLU Number
never equal to 0.
x…is the flag code which is reserved for
scale in POS system. y… is a MISC
code for total label. PLU’s Item-Code is
code in POS system.
No flag code defined. y… is a MISC
code for total label. PLU’s Item-Code is
code in POS system.
 If users need special bar code format, please use PC suite or contact with after-service center.
2.4 Measure Functions
 The scale offers 6 default measure units as kg, gram, ton, lb, 500g, 100g.
 Based on the difference national regulations, some of the measure unit may Not Open. The combinations
12
and recommended Spec settings are all shown below:
Weight
display
kg
g
g
lb
U.Price
display
/kg
/g
/100g
/lb
212
3
4
4
6
Spec
211 200
0or 3
3
0or 4
0
8
0
6
3
201
3
0
0
3
208
3
0
0
3
Instructions
Default
 Weight precision: The precisions are divied into four levels. Level 0 owns original 1/3000. Level 0 and
level 1 are available for commercial users while level 2 and level 3 are only available for industrial users
(“*” would be attached in the print of weight). Please refer to Spec213.
 We guarantee the stability and reliability for precision level 0 (1/3000) when the scale leaves factory. And
the higher precisions are here to satisfy the need of high definition print for some users, so factory would
not guarantee the stability and reliability for higher precision levels for every scale. Please choose the
precision prudentially.
 The request Zero-Return for scale print: it’s requested in commercial sales that total weight (sum of net
weight and tare weight) of the scale have to return to zero when the scale is going to print the weights of
two goods. But for industrial users, this rule could be ignored. Set the value of Spec069 to 2. (“Ind”
would be attached in the print of weight).
2.5 Sale Functions
 Users could operate accumulative sales with 4 customers at the same time. Please refer to the Example
4-28 in page 31 for operations.
 Rounding methods could be divided into rounding method for single and rounding method for total. The
settings of rounding methods are shown in Spec100 and Spec101.
 Suggest that set the value of Spec100 to 1 if users don’t want the unit “cent” to be displayed in sales.
 Suggest that set the values of Spec100 to 0 and Spec101 to 1 if users want the unit “cent” to be in sale
while unit “cent” is not displayed in grand total and print.
 The units’ conversion for PLU default U.Price: set PLU U.Price to 10.00, the unit is 500gram and unit
displayed is kg. When transfer PLU10, unti price is displayed as 20.00.
 Units’ conversion for temporary unit price: the scale offers the function of units’ conversion for temporary
unit goods and price from 500gram to kg. When U.Price’ display unit is /kg, set the value of Spec210 to
7 and the value of Spec073 to 1 to activate this function. Please refer to the Example 4-6 in page 22,
Example 4-20 in page 28.
 No Weigh Sale for Weight PLU: set the value of Spec071 to 1. When the weight returns to zero in weigh
sale, input the price and sell the goods at the price you input. Please refer to Example 4-10 in page 23.
 Users can discount on U.Price and T.Price conveniently. The discount methods include discount at a fixed
number, discount in subtraction and discount in percentage. Please refer to Discount Operations in page
25.
 Users can make a manual weight sale: set the value of Spec077 to non-zero (1, 2 or 3 are ok). Manual
13
weight entry can be executed if weight keeps at zero. Refer to the content of <manual weight> on page 1
 Total price Masked before printing: set the value of Spec130 to 1. It will not display current transaction
amount till press 【Print】key

Auto record after zero-return set the value of Spec 131 to 1 or 2 (1:unforced 2:forced)., scale still record
the transaction in un print condition, convenient to check and audit
 Auto printing after zero-return: set the value of Spec131 to 3. In weight sale, it will come back to zero in
PLU, it will print according to last stable weight.
 Forced auto printing after zero-return: set the value of Spec131 to 4. In weight sale, when record and valid
sale data it will auto printing after zero-return enable while user can not cancel the auto print by quit the
PLU.
2.6 Salesman Function
 User could enable salesman login functions. Please refer to Salesman in page 33 and Spec135.
2.7 Report Functions
 Users could print the total reports with time periods of last 32 stat. day, stat. month, stat. quarter or manual
time period.
 Users can print the reports for all departments, all classes and part of PLU (below 1000), with a time period
of present stat. day, stat. month, stat. quarter or manual time period.
 Please refer to Account Operations in page 64 for the details.
2.8 Sales details
 The scale not only with report print function,but also store the sales record in details, this record can
transfer to PC via internet, RS232 or U-disk.
 Because the storage room limit, if operator don’t transfer the details often, the scale will delete the old
record automatically to save the new records.
 The storage for the sales details is 6000 records (can enlarge into 10000 and more). Each cargo takes one
record.
2.9 Network function
 In local area network with a PC or Router enabled DHCP service, scales can connect to network directly
without any IP setting.
 If you want to nominate the IP for certain scale, to set Spec150~153 is for 4 segment of IP(Default is
192.168.0.0. When last segment is 0, that means scale connect with Network with way of DHCP. Also
means that default way is DHCP), Spec158~161 is for 4 segment of gateway of Network. (Default is
192.168.0.1).
 If the Network for the scale and PC is not in the same one, you can make that with directional connect way.
Directional connect include: From PC to scale (should nominate the IP of certain scale on the PC
software), and from scale to PC(should set Spec043 as 2-----client end mode, and set IP of PC at
14
Spec154~157)
 Spec166~Spec169 is for the scale’s Network Port, change these items may lead to abnormality with
Network. Normally please don’t modify these 4 items.
2.10 Ethernet Thermal Printer
 Device can connect with Ethernet thermal printer produced by our company, which uses as Remote Printer.
 User can connect Printer and device one-to-one with Crossover Cable. Or connect printers and devices to
Ethernet router (with DHCP function) for one-to-many, many-to-one, or many-to-many network.
 User can appoint special print format for Ethernet printer, which may different to printer on the device.
2.11 Software use
 In the CD, there is software manual, you can kindly install and use according to the manual.
 The user name of the PC software is user, the original password is blank.
 The administer name of the PC software is admin, the original password is 200806.
 You can click Help----Manual after run the software, to check the software manual.
15
3 Fast Prog
Fast prog is the programme operation that draws out some frequently-used programme functions and enables
users enter certain frequently-used programme interfaces without selecting in programme interface.
Please make sure system is in the interface of idle sale before transferring fast prog. If system is not in sale
operation, pressing 【Sale】 could enter the interface of idle sale. If system is in sale operation, pressing 【Cancel】
for several times could quit sale process and enter the interface of 『Sale Idle』. The sign of the interface of idle
sale is that two lights 〖Sale〗 and 〖Sum〗 are on. On contrary, if two light of 〖Sale〗 and 〖Single〗 are
on , system is in sale PLU interface.
3.1 Fast-Prog of PLU
Press 【F-Prog】+【PLU】 to enter PLU Fast Prog.
The process of programme is similar with PLU programme in standard programme interface. But users can
finish PLU Fast Prog in sale interface.
Example 3-1 Fast-Prog of PLU
Edit PLU10 as a weight PLU with the name Pork-2, U.Price $30.00/kg, cost $24.00/kg and tare 0.005g.
Operations
Keys
『Sale Idle』
Tare
0.000
【F-Prog】+ F23
PLU Fast Prog
【PLU】
PLU Number 【1】【0】 F23
Go to Next
F23
【】
Display
Weight/ Change/
Count
U.Price
0.000
0.00
PLU.00
Not Set
Step No. Step Info
PLU.00
Not Set
PLU.01
ICode
Input
Item-Code
90001
F23 PLU.01
ICode
Go to Next
【】
F23 PLU.03
Unit
Set as weight
PLU
【1】
F23 PLU.03
Unit
Go to Next
【】
F23 PLU.04
Price
Remarks
Single/
Total
0.00 〖Sale〗,〖Sum〗on.
0
〖Prog〗on.
Object
10
Number are between 1~9999999
0
ICode is Item-Code, which is usually
printed as part of letters on barcode
print. If the number of barcodes is
90001
default 2/5 or other custom numbers,
ICode are printed as a part of barcodes.
Please see details in chapter Barcode.
0
【0】,【1】: default weight unit;
【2】: default count unit;
【3】: kg weight unit;
【4】: g weight unit;
【5】: ton weight unit;
【6】: lb weight unit;
1
【7】: 500g weight unit;
【8】: 100g weight unit;
Please see details in unit chapter.
Default weight unit mean the unit used
for display. And it is suggested for
weight PLU.
0.00
16
Set U.Price 【3】
【0】
【00】F23 PLU.04
Go to Next
Set cost
Price
30.00
F23 PLU.05
Cost
0.00
【2】
【4】
【00】F23 PLU.05
Cost
24.00
0.000
【】
Go to Next
【】
F23 PLU.06
Tare
Set Tare
【5】
F23 PLU.06
Tare
Go to Next
Set name
Clear Original
Text
P
ork
Input number
2
Save edited
text
F23 PLU.14
【】
0
【Confirm】 En-1
【End】
Name
0
【Shift】
【p/P】EN-1
【o/O】【r/R】
EN-1
【k/K】
EN-1
【-】
1
P
4
rk
5
k-
6
-2
En-1
【Amend】 F23 PLU.14
When transferring PLU, it’s preset tare.
Don’t have to input it.
OK-Edit Input the names of goods.
0.005
Name
This 【Amend】 is to save text edit in
buffers instead of PLU. Please pay
OK-Edit attention: If users need save it in PLU,
users need to press【Amend】 again as
the step below.
0
If to print the shelf life date
Go to next
【】
F23 PLU.26
PS-UD
Print shelf date
【1】
F23 PLU.26
PS-UD
1
Go to next
【】
F23 PLU.31
PC-UD
0
Input shelf
days
【】
F23 PLU.31
PC-UD
3
Not Set
0
0.00
0.00
……
Save edited
【Amend】 F23 PLU.00
PLU
Return to sale 【Cancel】 0.000 0.000
The cost is used to calculate the profits.
Don’t have to input it.
In consideration of there was a text, we
suggest users press 【End】 before
editing. If editing in the original text,
users could use【】
【】 to move the
position of cursor.
EN-1
【2】
Preset U.Price in sale. Don't have to
input it. Users can temporarily input it
in sale.
0: Don't print PLU 31 invalid
1: Print. Continiune to set shelf days in
PLU.31
Shelf days. 0 means intraday valid,
followed like this.
If all cargo for one scale use same shelf
days, use Spec105 & Spec106
If other steps are still to be edited, users
can use 【】【】 to switch steps.
PLU10 is saved.
〖Sale〗,〖Sum〗 on
N o t e 1 Except the parts which have been instructed, meaning of the other words are listed in List of
Programme Interface in page 38.
N o t e 2 PLU fast-prog is forbidden when Spec080=0.
N o t e 3 Before you move to next step, the display of E1.01 Data Invalid means that the programme data you
input is invalid.
N o t e 4 The xx in PLU.xx means the content in the data which is marked with the number of xx in PLU fast
17
prog.
N o t e 5 Xx is not continuous when users press【】and【】to select the programme content. There are two
reasons. First reason is that the content in that part is meaningless. For example, tare is not present in
count PLU programme. The second reason is that the content in that part is seldom used and has been
set as non-programme content (Skip) in P3.01 and P3.02. Users could change that setting for personel
usage. Please refer to corresponding chapters for details.
3.2 Fast-Prog of Shortcut Key for PLU
Press 【F-Prog】+【SCxx】to enter PLU shortcut key programme. 【SCxx】could be one of 【SC1】~
【SC63】. After pressing one key, Users can input the PLU which the pressed key appoints to .Then press
【Amend】to save and exit.
Users can save without exit if they would like to go on to amend other shortcut keys. Press 【Confirm】 to
save the change and press another 【SCxx】 to amend. The number of input PLU must exist. User can select
existing PLU by pressing 【↑】【↓】. The process of programme is similar with scPLU programme in standard
programme interface. Please refer to the process shown below.
Example 3-2 Fast-Prog of Shortcut Key for PLU. Amend a shortcut key.
Operations
Keys
『Sale Idle』
Display
Remarks
Weight/ Change/ Single/
Tare
Count U.Price Total
0.000 0.000
0.00
0.00 〖Sale〗, 〖Sum〗 on.
PLU shortcut key
programme, and the
object is SC1
【F-Prog】+
【SC1】
F14
Input PLU number
【1】【0】
F14
scPLU
0-01
10
Save directly
【Amend】
0.000
0.000
0.00
0.00
scPLU
0-01
0
〖Prog〗on.
Key No. PLU No.
Save to the scale.
〖Sale〗, 〖Sum〗 on
N o t e 1 When Spec081=0, PLU shortcut-key fast-prog is forbidden.
Example 3-3 Fast-Prog of Shortcut Key for PLU. Amend two or more shortcut keys.
Operations
Keys
『Sale Idle』
PLU shortcut key
programme, and the
object is SC1
【F-Prog】+
【SC1】
Display
Remarks
Weight/ Change/ Single/
Tare
Count U.Price Total
0.000 0.000
0.00
0.00 〖Sale〗, 〖Sum〗 on.
F14
Input PLU number
F14
【1】【0】
Confirm input
【Confirm】 F14
Set SC2
F14
【SC2】
Input PLU number
F14
【1】【1】
Confirm input
【Confirm】 F14
Set Shift+SC1
【Shift】【SC1】 F14
Input PLU number 【1】【0】【0】 F14
scPLU
0-01
0
〖Prog〗on.
Key No. PLU No.
scPLU
scPLU
scPLU
scPLU
scPLU
scPLU
scPLU
0-01
-----0-02
0-02
-----1-01
1-01
10
------- Save to temporary buffer.
0
11
------- Save to temporary buffer.
0
100
18
Confirm input
【Confirm】
F14
scPLU
------
Save
【Amend】
0.000
0.000
0.00
Save to temporary buffer.
The last confirm can be
------skipped. Press 【Amend】
directly.
Save to the scale.
0.00
〖Sale〗, 〖Sum〗 on.
N o t e 1 When Spec081=0, PLU shortcut key fast prog is forbidden.
3.3 Fast-Prog of Spec Parameters
Press 【F-Prog】+【Prog】 to enter Spec parameters fast prog.
Please select the number you want to edit by pressing 【←】
【→】. The second window shows the number of
Spec which is being edited. The third window shows current parameters configuration. The fourth window shows
the data which has been edited by users.
Spec data parameters are made up of some number data. Refer to Definitions of Spec data parameters
in page 73 in order to understand functions of these parameters.
Press 【Amend】 to save and quit, or press【Cancel】to quit without saving. The process of programme is
similar with Spec programme in standard programme interface. For details, please refer to the process shown
below.
Here, we are going to amend Spec000 to 2, Spec002 to 77 and Spec040 to 99. We would present the
processes without discussing on the parameters we actually amend and their meanings.
Example 3-4 Fast-Prog of Spec Parameters
Operations
Keys
『Sale Idle』
Tare
0.000
F12
Change to 2
【F-Prog】+
【Prog】
【2】
Enter Spec002
【】【】
F12
Change to 77
Choose steps directly
【7】【7】
【×】
F12
Input step 40
【4】【0】
Confirm step
Change to 99
Save and exit
【Confirm】
【9】【9】
【Amend】
Spec fast prog
F12
F12
F12
0.000
Display
Remarks
Weight/ Change/
Single/
Count
U.Price
Total
0.000
0.00
0.00
〖Sale〗, 〖Sum〗on.
SP.000
1
1
〖Prog〗on.
Spec No. Origin Set Current Set
SP.000
1
2
Using【】
【】 can only
SP.002
0
0
get to amend items in Spec
amend level 0.
SP.002
0
77
Input
1-1
0
The input number of step
must be in Spec amend
Input
1-1
40
level 0 or 1. If not, the step
cannot be reached.
SP.040
0
0
SP.040
0
99
0.000
0.00
0.00
〖Sale〗, 〖Sum〗on.
N o t e 1 Spec fast-prog programme is forbidden when Spec082 = 0.
N o t e 2 Refer to Definitions of Spec data parameters in page 73 to know the definitions of data parameters .
Note 3
Read the definition of the parameter before you change it. And don’ t change any unknown
19
parameters in Spec programme.
N o t e 4 xxx in SP.xxx means the number of the data content in Spec programme.
N o t e 5 xxx is not continuous when users press 【】and【】 to select the programme content. Users can
only select Spec in level 0 by pressing 【】and【】. You have to input corresponding numbers
afterting pressing 【×】to change Spec in level 1. And users cannot reach Spec in level 2 and level 3
because their data are involved with some specifications in measurement and other hardware fields.
3.4 Fast-Prog of Unit price
After transfer PLU, press 【[email protected]】or【@Price】 to fast change this PLU’s price
Example 3-5 Fast-Prog of unit price (Spec083=1)
Display
Operations
Keys
Weight/ Change/
Tare
Count
U.Price
0.000 0.000
0.00
『Sale Idle』
Transfer PLU10 【1】
5.00
【0】
【PLU】0.000 0.000
Input the ameneded
6.00
【6】【0】【0】 0.000 0.000
price
Amend price
Exit
Long press【[email protected]】0.000
【Cancell】
0.000
Single/
Total
0.00
0.00
Remarks
〖Sale〗, 〖Sum〗on
0.00
0.000
6.00
0.00
0.000
0.00
0.00
PLU10’s default price change to
6.00
〖Sale〗, 〖Sum〗on.
N o t e 1 When Spec083=1, the step to amend unit price please refer to step 2: first judge whetherthe input
price in discount section or not, then set the accordant price as PLU’s default price
Example 3-6 Fast-Prog of unit price (Spec083=2)
Display
Operations
Keys
Weight/ Change/
Tare
Count
U.Price
0.000 0.000
0.00
『『Sale Idle』
Transfer PLU10 【1】
5.00
【0】
【PLU】0.000 0.000
Input the ameneded
6.00
【6】【0】【0】 0.000 0.000
price
Single/
Total
0.00
0.00
Remarks
〖Sale〗, 〖Sum〗on
0.00
Amend price
【[email protected]】
0.000
0.000
6.00
0.00
Exit
【Cancell】
0.000
0.000
0.00
0.00
PLU10’s default price change to
6.00
〖Sale〗, 〖Sum〗on.
N o t e 1 When Spec083=2, during the unit price amend, it will not judge the rationality of the imput price and
directly save as PLU’s default price
20
4 Sale Operations
4.1 Transfer and Lock of PLU
PLU9999999 is temporary by-weight goods (Spec93), PLU9999998 is temporary by-count goods (Spec94),
PLU9999997 is service charge (Spec95), user can use all other 7 digits PLU.
4.1.1 Transfer by Using PLU Number
Example 4-1 Use PLU Number to Transfer Weight PLU
Transfer PLU10, assuming PLU10 is a weight PLU with U.Price $2.00/kg and tare 0.100kg.
Operations
『Sale Idle』
Input number
Transfer PLU
Clear current PLU
Keys
【1】【0】
【PLU】
【Cancel】
Tare
0.000
0.000
0.100
0.000
Display
Remarks
Weight/ Change/ Single/
Count U.Price Total
0.000
0.00
0.00 〖Sale〗, 〖Sum〗 on.
0.000
0.10
0.00
-0.100
2.00
0.00 〖U.Price〗, 〖Single〗 on.
0.000
0.00
0.00
Example 4-2 Use PLU Number to Transfer Count PLU
Transfer PLU11, assuming PLU11 is count PLU with U.Price $5.00/pc.
Operations
『Sale Idle』
Input number
Transfer PLU
Clear current PLU
Keys
【1】【1】
【PLU】
【Cancel】
Tare
0.000
0.000
0.000
Display
Remarks
Weight/ Change/ Single/
Count U.Price Total
0.000
0.00
0.00 〖Sale〗, 〖Sum〗 on.
0.000
0.11
0.00
5.00
0.00 〖U.Price〗, 〖Single〗 on.
0.000
0.00
0.00
4.1.2 Tranfer by Using PLU Shortcut Keys
Example 4-3 Use PLU Shortcut Keys to Transfer Weight PLU
Transfer SC1, assuming SC1=PLU10 and it is a weitht PLU with U.Price $2.00/kg and tare 0.100kg.
Operations
『Sale Idle』
Input shortcut key
Clear current PLU
Keys
【SC1】
【Cancel】
Tare
0.000
0.100
0.000
Display
Remarks
Weight/ Change/ Single/
Count U.Price Total
0.000
0.00
0.00 〖Sale〗, 〖Sum〗 on.
-0.100
2.00
0.00 〖U.Price〗, 〖Single〗 on.
0.000
0.00
0.00 〖Sum〗 on
Example 4-4 Use PLU Shortcut Keys to Transfer Count PLU
Transfer SC2, assuming SC2=PLU11 and it is count PLU with U.Price $5.00/pc.
Operations
Keys
『Sale Idle』
Input shortcut key
Clear current PLU
【SC2】
【Cancel】
Display
Remarks
Weight/ Change/ Single/
Tare
Count U.Price Total
0.000 0.000
0.00
0.00 〖Sale〗, 〖Sum〗 on.
5.00
0.00 〖U.Price〗, 〖Single〗 on.
0.000 0.000
0.00
0.00 〖Sum〗 on
21
4.1.3 Transfer Temporary Weight PLU
Example 4-5 Transfer Temporary Weight PLU
Operations
『Sale Idle』
Input Unit Price
Set as a temporary
weight PLU,
Clear current PLU
Display
Remarks
Weight/ Change/ Single/
Tare
Count U.Price Total
0.000 0.000
0.00
0.00 〖Sale〗, 〖Sum〗 on.
1.30
0.00
【1】【3】【0】 0.000 0.000
Keys
【T-Sale】
0.000
0.000
1.30
0.00
〖U.Price〗, 〖Single〗 on.
【Cancel】
0.000
0.000
0.00
0.00
〖Sum〗 on.
N o t e 1 Temporary weight PLU could be converted into count PLU if users press【×】or the weight is zero.
N o t e 2 Temporary PLU’s number are decided by Spec093 (the default is 9999999)
Example 4-6 Transfer Temporary Weight PLU with a Unit Conversion of the U.Price.
Operations
『Sale Idle』
Input Unit Price
Set as a temporary
weight PLU, and
convert its unit.
Clear current PLU
Display
Remarks
Weight/ Change/ Single/
Tare
Count U.Price Total
0.000 0.000
0.00
0.00 〖Sale〗, 〖Sum〗 on.
1.70
0.00
【1】【7】【0】 0.000 0.000
Keys
【T-Sale】
0.000
0.000
3.40
0.00
〖U.Price〗, 〖Single〗 on.
Convert unit between 500g/kg
【Cancel】
0.000
0.000
0.00
0.00
〖Sum〗 on.
N o t e 1 Assume temporary weight unit is 500g (Spec210) and the unit of scale is kg. After input the U.Price
of 1.70 and press 【T-Sale】, the U.Price is converted into 3.40. That means the conversion of the unit
between 500g and kg is done.
4.1.4 Transfer Temporary Count PLU
Example 4-7 Temporary PLU number is decided by Spec094(default 9999998)
Operations
『Sale Idle』
Input Unit Price
Set as a temporary
count PLU
Clear current PLU
Display
Keys
Remarks
Weight/ Change/ Single/
Tare
Count U.Price Total
0.000 0.000
0.00
0.00 〖Sale〗, 〖Sum〗 on.
1.70
0.00
【1】【7】【0】 0.000 0.000
【×】
【Cancel】
0.000
1
1.70
1.70
〖U.Price〗, 〖Single〗 on.
0.000
0.00
0.00
〖Sum〗 on.
4.2 Manual Goods Sale
4.2.1 Sale and Print of Single Weight Goods
Example 4-8 Sale for Single Weight goods
Sell 1 kg PLU10 goods. Assume PLU10 is a weight PLU with U.Price is $2.00/kg and tare is 0.100kg.
22
Operations
『Sale Idle』
Transfer PLU10
Put on a weight
Print
Keys
Tare
0.000
【1】
【0】
【PLU】0.100
0.100
0.000
【Print】
Display
Remarks
Weight/ Change/ Single/
Count U.Price Total
0.000
0.00
0.00 〖Sale〗, 〖Sum〗on.
-0.100
2.00
0.00 〖U.Price〗,〖Single〗on.
0.900
2.00
1.80
0.000
0.00
0.00 Execute print.
N o t e 1 Two qualifications are indispensable when directly print without accumulating: 1. Current
accumulative buffer is empty, 2. The value of Spec060 is not 3 (forbid cashing mode with default zero
change).
N o t e 2 The system would have to wait for several seconds if users sell the weigh goods when the display of
weight is not stable. If the display of weight is stable in the waiting time, system would sell the goods
according to the operations. Please refer to Spec151 about the waiting time.
4.2.2 Sale and Print of Single Count Goods
Example 4-9 Sale and Print for Single Count goods
Sell 5pcs PLU11. Assume PLU11 is count PLU with U.Price is $5.00/pc.
Display
Operations
Keys
Remarks
Weight/ Change/ Single/
Tare
Count U.Price Total
0.000 0.000
0.00
0.00 〖Sale〗, 〖Sum〗on.
『Sale Idle』
Transfer PLU11 【1】
5.00
5.00
【1】
【PLU】
〖U.Price〗,〖Single〗on.
Input PLU11 amount 【×】【5】
5
5.00
25.00
Print
0.000 0.000
0.00
0.00 Execute print.
【Print】
N o t e 1 Two qualifications are indispensable when directly print without accumulating: 1. Current
accumulative buffer is empty, 2. The value of Spec060 is not set to be 3 (orbid cashing mode with
default zero change).
4.2.3 No Weigh Sale for Weight Goods
Example 4-10 No Weigh Sale for Weight PLU
Operations
Keys
Tare
0.000
『Sale Idle』
Transfer PLU10 【1】
【0】
【PLU】0.100
Input T.Price of goods 【3】【8】【0】 0.100
Print
【Print】
0.000
Display
Remarks
Weight/ Change/ Single/
Count U.Price Total
0.000
0.00
0.00 〖Sale〗, 〖Sum〗on.
-0.100
2.00
0.00 〖U.Price〗,〖Single〗on.
-0.100
3.80
0.00
Execute print. Or press
0.000
0.00
0.00 【Confirm】 to do cumulate
operations.
N o t e 1 To execute no weigh sale, the value of Spec071 needs to be set to 1 while the default value is 0.
N o t e 2 Temporary goods’ no weigh sale is not restricted by Spec071. And it could automatically convert to
count sale for temporary count goods.
23
4.2.4 Sale and Print for Different Kinds of Goods (No Cashing Mode)
Example 4-11 Sale and Print for Different Kinds of Goods (No Cashing Mode)
Sell 1kg PLU10 and 5pcs PLU11. Assume PLU10 is weight PLU with U.Price $2.00/kg and tare 0.100kg,
PLU11 is count PLU with U.Price $5.00/pc.
Operations
Keys
Tare
0.000
『Sale Idle』
Transfer PLU10 【1】
【0】
【PLU】0.100
Put goods PLU10 on
0.100
Confirm a goods
【Confirm】 0.000
Take goods PLU10 off
0.000
Transfer PLU11 【1】
【1】
【PLU】
Input the number of
【×】【5】
PLU11
Confirm a goods
【Confirm】 0.000
Print
0.000
【Print】
Display
Remarks
Weight/ Change/ Single/
Count U.Price Total
0.000
0.00
0.00 〖Sale〗, 〖Sum〗on.
-0.100
2.00
0.00 〖U.Price〗,〖Single〗on.
0.900
2.00
1.80
1.000
0.00
1.80 〖Sum〗on.
0.000
0.00
1.80
5.00
5.00 〖U.Price〗,〖Single〗on.
5
5.00
25.00
0.000
0.000
0.00
0.00
26.80
0.00
〖Sum〗on.
Execute print.
N o t e 1 Users can execute no cashing mode when the value of Spec60 is 0 or 1.
4.2.5 Sale and Print for Different Kinds of Goods (Cashing Mode, Input Payment)
Example 4-12 Sale and Print for Different Kinds of Goods (Cashing Mode, Input Payment)
Sell 1kg PLU10 and 5pcs PLU11. Assume PLU10 is weight PLU with U.Price $2.00/kg and tare 0.100kg,
PLU11 is count PLU with U.Price $5.00/pc. Payment is $30.
Operations
Keys
Tare
0.000
『Sale Idle』
Transfer PLU10 【1】
【0】
【PLU】0.100
Put goods PLU10 on
0.100
Confirm a goods
【Confirm】 0.000
Take goods PLU10 off
0.000
Transfer PLU11 【1】
【1】
【PLU】
Input the number of
【×】【5】
PLU11
Confirm a goods
【Confirm】 0.000
Input payment amount 【3】【0】【00】0.000
Print
Display
Remarks
Weight/ Change/ Single/
Count U.Price Total
0.000
0.00
0.00 〖Sale〗, 〖Sum〗on.
-0.100
2.00
0.00 〖U.Price〗,〖Single〗on.
0.900
2.00
1.80
1.000
0.00
1.80 〖Sum〗on.
0.000
0.00
1.80
5.00
5.00 〖U.Price〗,〖Single〗on.
5
5.00
25.00
0.000
0.000
0.00
30.00
26.80
26.80
3.20
26.80
0.00
0.00
【Print】
0.000
0.000
〖Sum〗on.
〖Change〗, 〖Sum〗 on.
Execute print.
Press any key to return. Or wait
several seconds to exit
according to the system setting
of Spec066.
N o t e 1 Cashing mode is available and change interface is displayed when the value of Spec060 is 1, 2, or 3.
24
4.2.6 Sale and Print for Different Kinds of Goods (Cashing Mode, Payment Equal to Price)
Example 4-13 Sale and Print for Different Kinds of Goods (Cashing Mode, Payment Equal to Price)
Sell 1kg PLU10 and 5pcs PLU11. Assume PLU10 is weight PLU with U.Price $2.00/kg and tare 0.100kg,
PLU11 is count PLU with U.Price $5.00/pc. Payment is $26.80.
Operations
Keys
Tare
0.000
『Sale Idle』
Transfer PLU10 【1】
【0】
【PLU】0.100
Put goods PLU10 on
0.100
Confirm a goods
【Confirm】 0.000
Take goods PLU10 off
0.000
Transfer PLU11 【1】
【1】
【PLU】
Input the number of
【×】【5】
PLU11
Confirm a goods
【Confirm】 0.000
If payment equal to
0.000
price, don’t input.
Print
Display
Remarks
Weight/ Change/ Single/
Count U.Price Total
0.000
0.00
0.00 〖Sale〗, 〖Sum〗on.
-0.100
2.00
0.00 〖U.Price〗,〖Single〗on.
0.900
2.00
1.80
1.000
0.00
1.80 〖Sum〗on.
0.000
0.00
1.80
5.00
5.00 〖U.Price〗,〖Single〗on.
5
5.00
25.00
0.000
0.00
26.80
0.000
0.00
26.80
0.00
26.80
0.00
0.00
【Print】
0.000
0.000
〖Sum〗on.
〖Change〗, 〖Sum〗 on.
Execute print.
Press any key to return. Or wait
several seconds to exit
according to the system setting
of Spec066.
N o t e 1 Cashing mode without input the amount of payment is available and change interface is displayed
when the value of Spec060is set to 2.
4.3 Discount Operations
4.3.1 U.Price Discount
The data after discount should be within the discountable area. If the data exceeds the area, discount
operation would fail.
Example 4-14 Execute Discount in Subtraction
Discount in U.Price: discount at the subtraction of $0.10/kg. Assume that PLU10 is weight PLU with U.Price
$2.00/kg and tare 0.100kg.
Operations
Keys
Tare
0.000
『Sale Idle』
Transfer PLU10 【1】
【0】
【PLU】0.100
Input discount data
【1】【0】 0.100
Discount in subtraction 【-Num】 0.100
Display
Remarks
Weight/ Change/ Single/
Count U.Price Total
0.000
0.00
0.00 〖Sale〗, 〖Sum〗on.
-0.100
2.00
0.00 〖U.Price〗,〖Single〗on.
-0.100
0.10
0.00
-0.100
1.90
0.00 〖Discount〗on.
Example 4-15 Execute Discount at a Fixed Number
Discount in U.Price: discount the U.Price to $1.80/kg. Assume that PLU10 is weight PLU with U.Price
25
$2.00/kg and tare 0.100kg.
Operations
Keys
Tare
Display
Remarks
Weight/ Change/ Single/
Count U.Price Total
0.000
0.00
0.00 〖Sale〗, 〖Sum〗on.
-0.100
2.00
0.00 〖U.Price〗,〖Single〗on.
-0.100
1.80
0.00
0.000
『Sale Idle』
Transfer PLU10 【1】
【0】
【PLU】0.100
Input discount data 【1】【8】【0】 0.100
Discount at a fixed
0.100 -0.100
【[email protected]】
number
1.80
0.00
〖Discount〗on.
4.3.2 T.Price Discount
The operations of T.Price discount and U.Price discount are the same. Under the condition that PLU is not
transferred and with accumulative buffers, execute discount operation is to discount on T.Price. The processes are
not repeated here. The limit of discount on T.Price is a accumulative value of U.Price discount limits of all goods.
4.3.3 ±% price
【±%】key and【-%】ket are the same key. When ±% price, the data object is floating-point decimal
fraction. For the same 5% discount, if input data is two digit decimal fraction, you need input 500; if with three
digit decimal fraction, then input 5000. you can long press【Shift】or【Fast prog】+【Shift】to change the decimal
point site.
Example 4-16 Input data to execute ±% price
U.Price-%price: at the percentage of 95%, as 
100.00  5.00
. Assume that PLU10 is weight PLU with
100.00
U.Price $2.00/kg and tare 0.100kg.
Operations
Keys
Tare
0.000
『Sale Idle』
Transfer PLU10 【1】
【0】
【PLU】0.100
Input discount data
【5】【00】 0.100
Discount in percentage
0.100
【±%】
Display
Remarks
Weight/ Change/ Single/
Count U.Price Total
0.000
0.00
0.00 〖Sale〗, 〖Sum〗on.
-0.100
2.00
0.00 〖U.Price〗,〖Single〗on.
-0.100
5.00
0.00
-0.100
1.90
0.00 〖Discount〗on.
N o t e 1 Default percentage discount is subtraction discount( Spec113=0) , if need to change the default
discount to additive, change Spec113=1
Example 4-17 Enterinterface and execute ±%price
Unit price+%price,charge 10% more.Assume that PLU10 is weight PLU with U.Price $2.00/kg and tare 0.100kg.
Display
Operations
Keys
Weight/ Change/
Tare
Count
U.Price
0.000 0.000
0.00
『Sale Idle』
Transfer PLU10 【1】
2.00
【0】
【PLU】0.100 -0.100
Single/
Total
0.00
0.00
Remarks
〖Sale〗, 〖Sum〗on.
〖U.Price〗,〖Single〗on.
26
Enter ±%price
interface
【±%】
Amend to +%
【±%】
Input 10%
【1】【0】【00】
Execute +%price
【Confirm】 0.100
-0.100
Sub-P
- 0.00
Add-P
Add-P
2.20
0.00
10.00
0.00
without any number before
【±%】
Sub-P means it is -%
〖Discount〗on.
N o t e 1 Press【±%】repeatedly to amend the operation symbol to ’+’ or’-’.
Example 4-18 Directly execute default ±%price(Spec114)
Unit price+%price( Spec113=1) , charge additional 20%( Spec114=20) . Assume that PLU10 is weight PLU with
U.Price $2.00/kg and tare 0.100kg.
Display
Operations
Keys
Weight/ Change/
Tare
Count
U.Price
0.000 0.000
0.00
『Sale Idle』
Transfer PLU10 【1】
2.00
【0】
【PLU】0.100 -0.100
Execute default
±%price
【±%】
0.100
-0.100
2.40
Single/
Total
0.00
0.00
0.00
Remarks
〖Sale〗, 〖Sum〗on.
〖U.Price〗,〖Single〗on.
without any number before
【±%】
〖Discount〗on.
N o t e 1 When execute default ±%price, the +/- are decided by Spec113, default price is decided by
Spec114
4.3.4 Auto Discount
When goods are working on auto discount, the price of activated PLU would change in real-time according
to the settings and system would shield any actions of manual change on the price.
Assume PLU20 is at the U.Price $10.00/kg. U.Price goes to $9.00/kg when sale weight is more than 1kg and
U.Price goes to $8.00/kg when sale weight is more than 2kg. The change of U.Price of this PLU is shown below:
Example 4-19 Auto Discount
Operations
Keys
Tare
0.000
『Sale Idle』
Transfer PLU20 【2】
【0】
【PLU】0.000
Put weight 1.5kg
0.000
Add weight 1kg
0.000
Take off all weight and
0.000
put on weight 0.5kg.
Display
Remarks
Weight/ Change/ Single/
Count U.Price Total
0.000
0.00
0.00 〖Sale〗, 〖Sum〗on.
0.000
10.00
0.00 〖U.Price〗,〖Single〗on.
1.500
9.00
13.50 〖Discount〗on.
2.500
8.00
20.00 〖Discount〗on.
0.500
10.00
5.00
〖Discount〗off.
N o t e 1 All details about the auto discount setting of PLU, please read definitions of auto discount settings in
List of Programme Interface on page 38 and Spec115 carefully. Suggest users edit the content on PC.
27
4.3.5 Unit Conversion of Temporary U.Price
Example 4-20 Unit Conversion of Temporary U.Price
Operations
Display
Remarks
Weight/ Change/ Single/
Tare
Count U.Price Total
0.000 0.000
0.00
0.00 〖Sale〗, 〖Sum〗on.
2.00
0.00 〖U.Price〗,〖Single〗on.
【1】
【0】
【PLU】0.100 -0.100
Keys
『Sale Idle』
Transfer PLU10
Input a Temporary
U.Price with the unit 【1】【8】【0】 0.100
of 500g
Unit conversion
【T-Sale】 0.100
-0.100
1.80
0.00
-0.100
3.60
0.00
N o t e 1 Spec210 is 7 (500g), and kg is the measure unit of the scale.
N o t e 2 Spec073 is 1: Put 【T-Sale】 into use of 【Unit Conversion】.
4.4 Setting and Lock of Tare
4.4.1 Weight Tare
Example 4-21 Weight Tare
Operations
『Sale Idle』
Put on tare object
Tare
Take off tare object
Cancel tare
Keys
【Tare】
【Tare】
Tare
0.000
0.000
0.050
0.050
0.000
Display
Remarks
Weight/ Change/ Single/
Count U.Price Total
0.000
0.00
0.00 〖Sale〗, 〖Sum〗on.
0.050
0.00
0.00
0.000
0.00
0.00
-0.050
0.00
0.00
0.000
0.00
0.00
N o t e 1 If users need to cancel tare, current total weight should be 0 and users do not input any number.
4.4.2 Number Tare
Example 4-22 Number Tare
Operations
Keys
『Sale Idle』
Input tare
tare
Cancel tare
【3】【2】
【Tare】
【Tare】
Tare
0.000
0.000
0.032
0.000
Display
Remarks
Weight/ Change/ Single/
Count U.Price Total
0.000
0.00
0.00 〖Sale〗, 〖Sum〗on.
0.000
0.32
0.00
-0.032
0.00
0.00
0.000
0.00
0.00
N o t e 1 Spec067 is 0: Number tare is forbidden
N o t e 2 Spec067 is 1: Use absolute value as tare. For example, when the tare definition is 0.001 and input is
0.32, tare is 0.032.
N o t e 3 Spec067 is 2: Use floating-point values as tare. For example, input 0.32 and after tare users would
get 0.320.
N o t e 4 When there are numbers in input window and total weight is not 0, weight tare is the priority.
28
4.4.3 Lock and Unlock of Tare
Example 4-23 Tare Lock and Unlock
Operations
Keys
Display
Weight/ Change/ Single/
Tare
Count U.Price Total
Remarks
〖Lock Tare〗 on
Lock tare
Long Press【Tare】
Other operations
Unlock tare
Long Press【Tare】
〖Lock Tare〗 off
N o t e 1 When you long press 【Tare】, you can hear one beep first (beep for correctness or error) . Hold
pressing for 4 seconds you will hear the beep for correctness.
N o t e 2 Once tare locked, it cannot be changed or cleared automatically. Only manual tare can change tare.
N o t e 3 Once tare locked, it cannot be unlocked unless users unlock tare manually.
4.5 Special sale mode
Except general sale mode, scale also with other 4 special sale mode: batch print model, pre-packing mode,
lock PLU mode, auto print mode
4.5.1 Enter and Exit of Special sale Mode
Example 4-24 Single key select of sale mode
Operations
Display
Weight/ Change/ Single/
Tare
Count U.Price Total
Keys
Remarks
『Sale Idle』
Enter Auto Mode
【Auto Mode】
Exit Auto Mode
【Auto Mode】
Enter prepack mode 【Prepack Mode】
Exit prepack mode 【Prepack Mode】
Enter auto print mode 【Auto print】
Exit auto print mode
【Auto print】
N o t e 1 【Auto Mode】key related mode are decided by Spec78
N o t e 2 Only for super market version scale with the 【Prepack Mode】【Auto print】and【lock PLU】key
N o t e 3 Under one special mode, press special mode key will exit present mode and back to general sale
mode
Example 4-25 Interface select sale mode
Operations
Keys
Display
Weight/ Change/ Single/
Tare
Count U.Price Total
Remarks
『Sale Idle』
Enter Mode select
interface
Long press
【Auto Mode】
【0】: General mode
【1】: Batch print mode
Mode 0 Normal 【2】: Prepack mode
【3】: Lock PLU mode
【4】: Auto print mode
29
Select auto print mode
Can use【←】
【→】
【COnfirm】
to select mode
【4】
『Auto print mode』
N o t e 1 Menu of sale mode selection enable by Spec79
4.5.2 Sale under batch print mode
Example 4-26 Batch Print mode
Batch print mode. Assume PLU11 is weight PLU with U.Price $2.00/kg and tare 0.100kg.
Operations
Keys
『Sale Idle』
Display
Remarks
Weight/ Change/ Single/
Tare
Count U.Price Total
0.000 0.000
0.00
0.00 〖Sale〗, 〖Sum〗on.
Long press
【Auto Mode】
Enter batch print mode
0.000
【1】
Transfer PLU11 【1】
【1】
【PLU】
Input quantity
【×】【5】
Confirm sale object
【Print】
Input the number of
【1】【0】
print copies
Confirm the number 【Confirm】
Mode 0 Normal
Enter mode select
0.000
5
Input
0.00
5.00
5.00
Count
Input
Count
0.00 〖Auto Mode〗on
5.00 〖U.Price〗,〖Single〗on.
25.00 If number is 1, omit this step
0
10
Press 【Cancel】 to exit print in
midway.
Print 10 copies
Print ends
Exit quantity input
Exit PLU
Exit Auto Mode
5
0.000
0.000
0.000
0.000
5.00
5.00
0.00
0.00
5.00
25.00
0.00
0.00
0.000 〖Sum〗 on.
0.000 〖Auto Mode〗off.
N o t e 1 Under Batch print mode, user can accumulate, after accumulate , press【Print】select the print times
4.5.3 Sale under prepack mode (only for weight PLU)
Example 4-27 Prepack mode(only for weight PLU)
Prepack mode for weight PLU. Assume PLU10 is weight PLU with U.Price $2.00/kg and tare 0.100kg.
Operations
『Sale Idle』
Keys
Display
Remarks
Weight/ Change/ Single/
Tare
Count U.Price Total
0.000 0.000
0.00
0.00 〖Sale〗, 〖Sum〗on.
Long press
【Auto Mode】
Enter prepack mode
0.000
【1】
Transfer PLU10 【1】
【0】
【PLU】0.100
Put goods PLU10 on
0.100
After weight is stable.
0.100
Take goods PLU10 off
0.100
Put goods PLU10 on
0.100
After weight is stable.
0.100
Take goods PLU10 off
0.100
Mode 0 Normal
Enter mode select
0.000
-0.100
0.900
0.900
-0.100
1.900
1.900
-0.100
0.00
2.00
2.00
0.00
0.00
2.00
0.00
0.00
0.00
0.00
1.80
1.80
0.00
3.80
0.00
0.00
〖Auto Mode〗,〖lock PLU〗on
〖U.Price〗,〖Single〗on.
Print automatically.
Print automatically.
30
……….
Exit PLU
Exit Auto Mode
【Cancel】
【Auto Mode】
〖Sum〗 on.
〖Auto Mode〗〖
, lock PLU〗off.
N o t e 1 Pre-packing enable if Spec078 is set to 2.
4.5.4 Sale under Lock PLU mode
Under lock PLU mode, cargo cannot be accumulated and after finish the sale, will not exit the present PLU
automatically.
4.5.5 Auto print mode (only for weight PLU)
Under auto mode, when the weight is stable, print automatically.
4.6 Operations of Sale Buffers
4.6.1 Switch of Sale Buffers
Example 4-28 Switch of Sale Buffers
Operations
Keys
Display
Weight/ Change/ Single/
Tare
Count U.Price Total
『Sale Idle』
0.000 0.000
Default buffer V1
Transfer PLU10
【1】
【0】
【PLU】0.100 -0.100
Put goods PLU10 on
0.100 0.900
Confirm a goods
【Confirm】 0.000 1.000
Service other customers,
for current customer
……
delay checking out
0.00
2.00
2.00
0.00
Remarks
〖Sale〗, 〖Sum〗on.
〖V1〗 glittering.
0.00 〖U.Price〗,〖Single〗 on.
1.80
1.80 〖Sum〗 on.
0.00
0.000
0.000
0.00
〖V1〗on: means that there is
sale data in the buffer.
0.00
〖V2〗glittering: means that
buffer『V2』is working
Execute sales. Users
can switch to V3, V4
……
according to demands.
Continue sale buffered in
……
V1 for customer return.
Switch buffer V1
0.000
【V1】
Transfer PLU11
【1】
【1】
【PLU】
Input PLU11 amount
【×】【5】
Confirm a goods
【Confirm】 0.000
If payment is equal to
0.000
total, don’t input.
1.000
5
0.000
0.00
5.00
5.00
0.00
1.80 〖V1〗 glittering.
5.00 〖U.Price〗,〖Single〗 on.
25.00
26.80 〖Sum〗 on.
0.000
0.00
26.80
0.00
26.80
Switch buffer V2
Print
【V2】
【Print】
〖Change〗, 〖Sum〗 on.
Execute print.
Finished sales buffered
in V2~V4.
31
4.6.2 Cancel Sale Data in Sale Buffers
Example 4-29 Clear All Data in Current Sale Buffers
Operations
Keys
Tare
0.000
『Sale Idle』
Transfer PLU10 【1】
【0】
【PLU】0.100
Put goods PLU10 on
0.100
Confirm a goods
【Confirm】 0.000
Take goods PLU10 off
0.000
Transfer PLU11 【1】
【1】
【PLU】
Input PLU11 amount 【×】【5】
Confirm a goods
【Confirm】 0.000
02.00
Enter cancel interface 【Amend】
Total
Clear all data
【Confirm】 0.000
Display
Remarks
Weight/ Change/ Single/
Count U.Price Total
0.000
0.00
0.00 〖Sale〗, 〖Sum〗on.
-0.100
2.00
0.00 〖U.Price〗,〖Single〗 on.
0.900
2.00
1.80
1.000
0.00
1.80 〖Sum〗 on.
0.000
0.00
1.80
5.00
5.00 〖U.Price〗,〖Single〗 on.
5
5.00
25.00
0.000
0.00
26.80 〖Sum〗 on.
6
26.80
Piece
Total 〖Sum〗 on.
Number
Price
0.000
0.00
0.00 〖Sum〗 on.
Example 4-30 Clear One Goods in Current Sale Buffer
Operations
Keys
Tare
0.000
『Sale Idle』
Transfer PLU10 【1】
【0】
【PLU】0.100
Put goods PLU10 on
0.100
Confirm a goods
【Confirm】 0.000
Take goods PLU10 off
0.000
Transfer PLU11 【1】
【1】
【PLU】
Input PLU11 amount 【×】【5】
Confirm a goods
【Confirm】 0.000
02.00
Enter amend interface 【Amend】
Total
Use 【←】【→】to
select goods
Confirm amendment
02.01
【→】
Goods
1
【Confirm】 0.000
Display
Remarks
Weight/ Change/ Single/
Count U.Price Total
0.000
0.00
0.00 〖Sale〗, 〖Sum〗on.
-0.100
2.00
0.00 〖U.Price〗,〖Single〗 on.
0.900
2.00
1.80
1.000
0.00
1.80 〖Sum〗 on.
0.000
0.00
1.80
5.00
5.00 〖U.Price〗,〖Single〗 on.
5
5.00
25.00
0.000
0.00
26.80 〖Sum〗 on.
6
26.80
Piece
Total 〖Sum〗 on.
Number
Price
0.900
10
1.80
PLU
Single 〖Single〗on.
Amount
Number Price
0.000
0.00
25.00 〖Sum〗 on.
N o t e 1 In amend window: the window of tare is in the form of xx xx. The first part shows accumulative
times; the latter part is the object to be amended. 00 is total and 01~31 are accumulative number.
N o t e 2 If users amend the total, the whole deal is cleared.
N o t e 3 If users amend xx goods, information of xx goods is cleared. And if there was a T.Price discount,
T.Price discount information is cleared. T.Price will be calculated based on U.Price (or discounted
U.Price) and amount of sold goods.
N o t e 4 If T.Price is selected, the window of 『Weight/Count』 will display piece number of sold goods. The
definition of piece number is: 5 count goods add 5 and each weight goods add 1.
32
4.7 Salesman and Waiter
4.7.1 Personnel Information
Please refer to Salesman Programme in page 56. Salesman and waiter use the same personnel sheet.
4.7.2 Salesman Function
Salesman Function is disabled as default. User can enable it at Spec135. Normally, Set Spec135=2 or 4.
Only non-zero password Personnel can login as salesman when Spec135=4 or 5.
User need to input salesman’s number and password in the login menu before get into sale menu when
salesman function is enable.
4.7.3 Waiter Function
Do not enable in the common version, and do not have corresponding key.
4.8 Inquiry of Sale Records and Markers of Returns of Goods
Mark the tenth item in the sale record as return of goods.
Example 4-31 Inquiry of Sale Records and Markers of Returns of Goods
Operations
Keys
『Sale Idle』
Tare
0.000
2
Note 2
Enter『Sale Records』
Other information of
record items
Other information of
record items
Other information of
record items
See previous record
See record 10
Other information of
record items
Other information of
record items
Other information of
record items
Sign as a return goods
Long Press
【Amend】
Display
Remarks
Weight/ Change/ Single/
Count
U.Price Total
0.000
0.00
0.00 〖Sale〗, 〖Sum〗on.
5
11
25.00 If there is data in current
buffer, system would first enter
PLU
Amount
Price
buffer interface, long press will
Number
enter current interface,. If there
is no sale records, it will not
enter this interface
Information Page 1
Sale time of records.
05 24
09 08 59 W-6
Information Page 2
Note 1
15
15
Note 3
Information Page 3
Note 4
【↓】
2008
【↓】
Note 5
【↓】
02.02
5
11
25.00
【←】
【×】
【1】【0】
【Confirm】
02.01
0.900
Input
10
1-1
1.80
0
01.01
1.000
12
2008
05 24
08 01
39 W-6
15
10
【↓】
【↓】
Switch to the
4.00 number record.
【↓】
01.01
1.000
12
4.00
【F-Prog】+
【Amend】
01.01
1.000
12
4.00
10 here
number.
is
the
appointed
appointed
33
Return to sale mode
【Cancel】
0.000
0.000
0.00
0.00 〖Sale〗, 〖Sum〗on.
N o t e 1 The record are divided into deal head record and deal detailed record, deal head record include deal
data of FID , SID, deal discount sum,etc; deal detailed record include the detailed cargo deal
information
N o t e 2 When display deal head record, here display ‘----’, when display deal detailed record, here display
this goods are which number cargo
N o t e 3 When display deal head record, here display this deal’s SID (code ID, refer to Spec140), when
display deal detailed record, here is blank
N o t e 4 The number shown in the window of change / U.Price is the amount of sale record stored in the scale.
When the number is close to 8000, the scale would delete the earlist records automaticlly. And
Single/Total Price window shows the sequence number of this record in all the records
N o t e 5 If present record are marked as goods return, the window will display“-RT-”.
4.9 Manual Weight
4.9.1 Manual Sale of Manual Weight Entry
Example 4-32 Manual Sale of Manual Weight Entry
Sell 1 kg PLU10 goods. Assume PLU10 is a weight PLU with U.Price is $2.00/kg and tare is 0.100kg.
Operations
Keys
Tare
0.000
『Sale Idle』
Transfer PLU10 【1】【0】【PLU】0.100
Manual weight entry 【Manual Weight】
Weight data
【1】【0】【00】
Put on a weight
---【Confirm】
Print
0.000
【Print】
Display
Remarks
Weight/ Change/ Single/
Count U.Price Total
0.000
0.00
0.00 〖Sale〗, 〖Sum〗on.
-0.100
2.00
0.00 〖U.Price〗,〖Single〗on.
Man
Weight 0.000
Man
Weight 1.000
1.000
2.00
2.00 【Manual Weight】on
0.000
0.00
0.00 Execute print.
N o t e 1 Manual weight entry need Spec077 set to non-zero (1, 2 or 3 are all ok).
N o t e 2 Manual weight entry can be executed only if weight keeps at zero and stable.
N o t e 3 In manual weight sale process, tare function is forbidden, 〖Manual Weight〗 on, and “ManWT” is
printed before weight data.
4.10 Bar code printing and scanning
4.10.1 Exterior bar code
Exterior bar code is EAN/UPC barcode normally, which is defined by the standards organisation GS1.
If user look for commodity by exterior bar code, user need to input the commodity’s bar code to PLU’s
Index Barcode, after the scanner scan the bar code, it will search and transfer the same index PLU auotmatically.
When user edit the PLU on the scale, scan the exterior bar code during the PLU numbwe step, it will transfer
the PLU related to the exterior bar code; if scans the exterior bar code in other step, it will consider this bar code
as present PLU’s index barcode.
34
4.10.2 Interior bar code
Interior bar code is user appointed barcode format and only used in small are, generally used for
communication between barcode scale and cash machine like cash register scale or cash register machine.
In the rule of EAN-UCC, define the prefix code 20-29 as shop inside use to avoid the repeatance with EAN
code. So, if user uses both exterior and interior bar code, then interior bar code ‘s prefix must inside 20-29.
To meet the different request, the interior bar code’s format can be defined by user, but the print device
(barcode label scale) and scan device (cash register scale or cash register) must with the same format, then the
interior bad coe can be exactly recognised
35
5 Programme Operations
5.1 Please Read this Part First
For ordinary users, they can use 3 kinds of Fast Progs in Fast Prog in chaper 3 to handle most applications.
There are detailed programme operations of the scale in this chapter, as well as examples for users. But some
parts of programme content are very complicated such as print format edit and barcode format edit. Devisers
suggest users use company offered software when users are in need of these functions. The company software
offers users a convenient interface to edit all the working parameters and sale data of the scale. The setting data
can be downloaded from Ethernet (real-time download), or transferred in the form of files by USB flash disk
(Users edit the data on PC and store data in USB flash disk, then download data to scale from USB flash disk.).
Devisers are convinced that it’s easy to learn to use the company software. As long as users own basic
computer operation knewledge and learn with user menual of this software (User menual would be
installed with the software), users can operate the software in a very short time. If users cannot use
computer and are still in need of complicated programme operations, users can write down the demands
and send to us.
If computers cannot be used in users’ circumstances, and users are indeed in need of functions of this part,
please read content in this chapter carefully. In consideration of too much content, detailed example instructions of
all operations will not be provided in some chapters. But all the functions are instructed in words and processes
are arranged in sequence of steps. Users should read Tree-shaped Design of Edit Steps and Frequently-used Keys
in Prog Interfaces first carefully. Then do programme operations according to instructions in List of Programme
Interface and corresponding chapters on the basis of fully understanding of these two parts.
5.2 Basic Operations in Programme Interface
5.2.1 Tree-shaped Design of Edit Steps
P1
Prog
Menu
P2
P3
P4
P11
Time
P12
Spec
P13
Sring
P14
PLU Shortcut
P21
Dept.
P22
Class
P23
PLU
P24
Unit
P25
Barcode
P26
Print format
P27
P31
P32
Salesman
PLU Prog steps
PLU F-Prog steps
P33
Delete Sale data
Communications P41
(Commu)
P42
USB flash disk
Ethernet
Scale Paramete
(TM-Set)
Sale Data
(DT-Set)
Data Assistant
(DT-Ass)
Press 【Prog】 first enter P1;
Use【←】 and 【→】to select one of P1
to P5. Use 【Confirm】 to select
corresponding programme operations;
Or press【1】~【5】directly to enter P1~
P5;
Then use the way to go to Next.
The operations are a little different in
various programme operations. But they
are almost designed into tree-shaped.
Instructions and examples about each part
would be in following chapters.
.
Note: Communication ways of P4 depend
on the hardware of the scale. And basic
36
P43
P44
Hardware Assistant P51
P5
(HWAss)
P52
RS232
USB slave
Set the passwords
Factory default
hardware only has P41.
P1.-TM-Set
Fast Prog
Time
Spec
String
ScPLU
Dept.
Class
PLU
Bcode
Label
Sales
P2.-DT-Set
Unit
ProgMenu
P3.-DT-Ass
SK-PLU
SKFPLU
Delete
P4.-Commu
U-Disk
Ethnet
RS232
USlave
P5.-HW-Ass
Set-PW
TMS-DF
Note: Hardware information must be operated in this machine.
Picture 5-1 Sketch map of tree-shaped design of edit interface
5.2.2 Frequently-used Keys in Prog Interfaces
 【Amend】: Save the amended content and go back to previous interface. If operation is in DTSet, go
37
back to step 0 after save and wait for new number to be input to amend.
 【Cancel】: Don’t save and go back to previous interface.
 【Confirm】: Get into next step to edit. Such as enter P3 by pressing 【Confirm】 when operation is in
P31. And press 【Confirm】 to enter certain edit interface when operation is in text edit or in edit
interface of print format. Then press 【Amend】 to save and exit, or press 【Cancel】 to exit without
saving.
 【←】、【→】: Steps selection. Such as press 【←】 and【→】 to select steps P21~ P27
 【↑】、
【↓】: Press 【↑】
【↓】 to select previous or next valid data when amending data in programme.
And its function is the same as 【←】【→】 in some interfaces when no data is to be amended.
 【0】~【9】
、00: Input corresponding numbers.
 【back】: Delete the last digit number.
 【×】: For so many steps to select in processes of Spec and DTSet edit operations in TMSet, users can use
【×】 to select step to edit. There would be a hint for you to input the step number you want to select
after you press【×】. Please input the number and press 【Confirm】.
5.2.3 List of Programme Interface
Menus
P1
Menu Prompt
TMSet
Instructions
P11
TMSet
Time
P12
TMSet
Spec Spec Parameters setting
P12
SP.000
……
……
P12
SP.249
P13
TMSet
Spec 000
…… ……
Spec 249
ST.000 ShopN String 0: Store name
P13
ST.001 ScaleN String 1: Device name
P13
ST.002 MnyPre String 2: Prefix of Money Unit
P13
ST.003 MnySuf String 3: Suffix of Money Unit
P2
DTSet
Scale Data setting
DPT.00 NoSet Dept.0: Number
P21
DPT.01
Name Dept.1: Name
DTSet
Class Class
P22
CLS.00 NoSet Class 0: Number
P22
CLS.01 Name Class 1: Name
P22
CLS.00
Dept Class 2: Dept. that it belong to
DTSet
PLU PLU
P23
Definitions of Spec data parameters
Dept Dept. setting
P21
P22
Spec 000~249, see details in chapter 7.2
TMSet scPLU PLU shortcut key setting
DTSet
P21
State
String Text setting
P13
P14
Remarks
BarCode Scale Setting
Available dept edit number: 10~99.
Available class edit number 10~99
P23
PLU.00 NoSet PLU 0: Number
Available PLU edit number 1~9999999.
P23
PLU.01 ICode PLU 1: Item Code
Be printed with barcodes.
P23
PLU.02 Index PLU 2: Index for exterior barcode
38
Menus
Menu Prompt
Instructions
Remarks
State
1 is default weight unit;
2 is default weight unit;
3 is kg weight unit;
P23
PLU.03
Unit
PLU 3: Unit
4 is g weight unit;
5 is ton weight unit;
6 is pound weight unit;
7 is 500g weight unit;
8 is 100g weight unit.
P23
PLU.04
Price PLU 4: U.Price
P23
PLU.05
Cost
PLU 5: Cost
P23
PLU.06
Tare
PLU 6: Tare
P23
PLU.07 Lab-1 PLU 7: Print format number of 1st bill
P23
PLU.08 BarT1 PLU 8: Barcode number of 1st bill
P23
PLU.09 BarF1 PLU 9: Barcode flag of bill 1st bill
P23
PLU.10 Lab-2 PLU 10: Print format number of 2nd bill
P23
PLU.11 BarT2 PLU 11: Barcode number of 2nd bill
P23
PLU.12 BarF2 PLU 12: Barcode flag of 2nd bill
P23
PLU.13
P23
PLU.14 Name PLU 14: Goods name
P23
PLU.15 Des-1 PLU 15: Goods postil 1
P23
PLU.16 Des-2 PLU 16: Goods postil2
P23
PLU.17 Des-3 PLU 17: Goods postil3
P23
PLU.18 Des-4 PLU 18: Goods postil4
P23
PLU.19 Des-5 PLU 19: Goods postil5
P23
PLU.20 Des-6 PLU 20: Goods postil6
P23
PLU.21 Des-7 PLU 21: Goods postil7
P23
PLU.22 PS-SD PLU 22: Sale date print
Class PLU 13: class that it belongs to
0: not print, 1: print.
0: not print, 1: print at appointed time,
P23
PLU.23 PS-ST PLU 23: Sale time print
P23
PLU.24 PS-PD PLU 24: Packing date print
P23
PLU.25 PS-PT PLU 25: Packing time print
P23
PLU.26 PS-UD PLU 26: Shelf date print
0: not print, 1: print.
P23
PLU.27 PC-SD PLU 27: Sale days data
Number of days after current day.
P23
PLU.28 PC-ST PLU 28: Sale time data
Appointed time for print.
P23
PLU.29 PC-PD PLU 29: Packing days data
Number of days after current day.
2: print printing time.
0: not print, 1: print.
0: not print, 1: print at appointed time,
2: print printing time.
P23
PLU.30 PC-PT PLU 30: Packing time data
Appointed time for print.
P23
PLU.31 PC-UD PLU 31: Shelf days data
Number of days after current day.
P23
PLU.32 DF-D PLU 32: Manual discount lower limit
0: use system setting; 1: no lower limit;
2: Take original cost as lower limit;
3: Take PLU.34 as lower limit.
0: use system setting; 1: no upper limit;
P23
PLU.33 DF-U PLU 33: Manual discount upper limit
2: Take original U.Price as upper limit;
3: Take PLU.35 as upper limit.
P23
PLU.34 DF-DN
P23
PLU.35 DF-UN
PLU 34: Value of manual discount lower
limit
PLU 35: Value of manual discount upper
limit
Activated when DF_D=3.
Activated when DF_D=3.
39
Menus
P23
Menu Prompt
Instructions
PLU.36 DA-S0 PLU 36: Customize 0 of auto disount
Remarks
State
0: not activate; 1: discount on count;
2: discount on periods of time.
Sunday: 1, Monday: 2, Tuesday: 4
Wednesday: 8, Thursday: 16, Friday: 32
Saturday: 64. When this customization discount
P23
PLU.37 DA-W0 PLU 37: Activation day of the customize
needs to be activated at some certain days, input
add-up number of these days here. To input 127
means that the discount is activated all the days.
To input 1+64=65 if the discount is only
activated at Saturday or Sunday.
Execute this discount way in this customization
PLU 38: The Lower limit of
P23
PLU.38 DA-D0 customization activation period
Start at this point (include this point)
activation period.
Input weight/count according to the unit of PLU
when discount on amount. When inputing
count, 10 goods needs to input 10.000 or move
decimal (long press 【Shift】 or 【F-Prog】+
PLU 39: The upper limit of
P23
PLU.39 DA-U0 customization activation period
End at this point (not include this point)
【Shift】) to input 10. Avoid inputing 0.010 for
10 pcs.
When discount on time, the format of input
time is HHMM. If the time is 20: 30, users need
to move decimal to input 2030.
If number is positive, discount number would
replace U.Price. If number is minus, new
P23
PLU.40 DA-N0 PLU 40: Discount Price of customize
U.Price is the price that subtracts the input
number from former U.Price. But minus values
cannot be input in the scale.
P23
PLU.41 DA-S1 PLU 41: Customize 1 of auto disount
P23
PLU.42 DA-W1 PLU 42: Activation day of the customize
P23
PLU.43 DA-D1
P23
PLU.44 DA-U1
P23
PLU.45 DA-N1 PLU 45: Discount Price of customize
P23
PLU.46 DA-S2 PLU 46: Customize 2 of auto disount
P23
PLU.47 DA-W2 PLU 47: Activation day of the customize
P23
PLU.48 DA-D2
P23
PLU.49 DA-U2
P23
PLU.50 DA-N2 PLU 50: Discount Price of customize
P23
PLU.51 DA-S3 PLU 51: Customize 3 of auto disount
P23
PLU.52 DA-W3 PLU 52: Activation day of the customize
P23
PLU.53 DA-D3
PLU 43: The Lower limit of
It’s the same as last customize discount.
customization activation period
After the edit of last customize discount it
PLU 44: The upper limit of
can be edited.
customization activation period
PLU 48: The Lower limit of
It’s the same as last customize discount.
customization activation period
After the edit of last customize discount it
PLU 49: The upper limit of
can be edited.
customization activation period
PLU 53: The Lower limit of
It’s the same as last customize discount.
customization activation period
After the edit of last customize discount it
PLU 54: The upper limit of
can be edited.
P23
PLU.54 DA-U3
P23
PLU.55 DA-N3 PLU 55: Discount Price of customize
customization activation period
40
Menus
Menu Prompt
Instructions
Remarks
State
0: excute tax rate according to Spec 116,117
1: tax free price mode
P23
PLU56
Tax-S PLU56: tax rate sort
2:: tax free price mode, input unit price is price
duty paid
3.with tax price mode
P23
P24
PLU.57 Tax-D PLU57: tax rate percentage
DTSet
Unit
0.01% tax rate,17% input 1700
Unit
P24
UNT.00 NoSet Unit 0: Number
P24
UNT.01 Name Unit 1: Name
P24
UNT.04 PUnit
Unit 4: Measure Mode(just open
1 is default weight unit,
weighing mode)
2 is default count unit,
Not Open
In weighing mode, means how much gram as
P24
UNT.05
Pack Unit 5: Packing
one packing
In counting mode, means how many pcs as one
Not Open
packing
P25
DTSet
Bcode Barcode
P25
BAR.00 NoSet Barcode 0: Number
P25
BAR.01 Name Barcode 1: Name
P25
BAR.02
Edited number of barcode when leaving factory
are 1~9. Available barcode edit number 10~99.
Type Barcode 2: Type
P25
BAR.03 Check Barcode 3: Checkout
P25
BAR.04 NCon1 Barcode 4: Constant number 1
P25
BAR.05 NCon2 Barcode 5: Constant number 2
Please pay attention that edit content should
P25
BAR.05
Des
Barcode 6: Data format description
accord with certain format: refer to chapter of
barcode.
P26
DTSet
PSets Print format
P26
PST.00 NoSet Print format 0: Number
P26
PST.01
P26
PST.02
P26
PST.03 Lng-X Print format 3: Width
Edited label in factory: 1~9;
Available label edit number 10~29.
Name Print format 1: Name
Sort
Print format 2: Using sort
P26
PST.04 Lng-Y Print format 4: Height
P26
PST.05
Txt01 Print format 5: Text 1
P26
PST.06
Txt02 Print format 6: Text 2
P26
PST.07
Txt03 Print format 7: Text 3
P26
PST.08
Txt04 Print format 8: Text 4
P26
PST.09
Txt05 Print format 9: Text 5
P26
PST.10
Txt06 Print format 10: Text 6
P26
PST.11
Txt07 Print format 11: Text 7
P26
PST.12
Txt08 Print format 12: Text 8
P26
PST.13
Txt09 Print format 13: Text 9
P26
PST.14
Txt10 Print format 14: Text 10
P26
PST.15
Txt11 Print format 15: Text 11
P26
PST.16
Txt12 Print format 16: Text 12
P26
PST.17
Txt13 Print format 17: Text 13
P26
PST.18
Txt14 Print format 18: Text 14
41
Menus
Menu Prompt
Instructions
Remarks
P26
PST.19
Txt15 Print format 19: Text 15
P26
PST.20
Txt16 Print format 20: Text 16
P26
PST.21 FontM Print format 21: Font mode
P26
PST.22
State
Suggest new font mode after V2.03 but still
support old font
LAS Print format 22: Print Item
P26 LAS.00 NoSet Print item 0: Item number
Available print item edit number 0~99.
P26 LAS.01 Flag1 Print item 1: Symbol 1
P26 LAS.02 Flag2 Print item 2: Symbol 2
P26 LAS.03 Flag3 Print item 3: Symbol 3
P26 LAS.04
Print Print item 4: Print state
P26 LAS.05 Angel Print item 5: Print angle
P26 LAS.06
Grid Print item 6: Type of snap to grid
P26 LAS.07 CFont Print item 7: Print font
P26 LAS.08
S-X
Print item 8: Start position X
P26 LAS.09
S-Y
Print item 9: Start position Y
P26 LAS.10
L-X
Print item 10: Area length X
P26 LAS.11
L-Y
Print item 11: Area length Y
P27
DTSet
Sales Salesman
Available salesman edit number 10~99
P27
SAL.00 NoSet Salesman 0: Number
P27
SAL.01 Name Salesman 1: Salesman name
P27
SAL.02
P3
Pass
DTAss
P31
Salesman 1: Salesman password
Data assistant
DTAss Sk-PLU PLU Prog skip step setting
P31
PLU.00 NoSet PLU 0: Number
P31
PLU.01 ICode PLU 1: Item Code
P31
PLU.02 Index PLU 2: Index for exterior barcode
P31
PLU.03
Unit
P31
PLU.04
Price PLU 4: U.Price
P31
PLU.05
Cost
PLU 5: Cost
P31
PLU.06
Tare
PLU 6: Tare
P31
PLU.07 PST-1 PLU 7: Print format number of 1st bill
P31
PLU.08 BarT1 PLU 8: Barcode number of 1st bill
P31
PLU.09 BarF1 PLU 9: Barcode flag of bill 1st bill
P31
PLU.10 PST-2 PLU 10: Print format number of 2nd bill
P31
PLU.11 BarT2 PLU 11: Barcode number of 2nd bill
PLU 3: Unit
nd
P31
PLU.12 BarF2 PLU 12: Barcode flag of 2 bill
P31
PLU.13
P31
PLU.14 Name PLU 14: Goods name
P31
PLU.15 Des-1 PLU 15: Goods postil 1
P31
PLU.16 Des-2 PLU 16: Goods postil2
P31
PLU.17 Des-3 PLU 17: Goods postil3
P31
PLU.18 Des-4 PLU 18: Goods postil4
P31
PLU.19 Des-5 PLU 19: Goods postil5
P31
PLU.20 Des-6 PLU 20: Goods postil6
P31
PLU.21 Des-7 PLU 21: Goods postil7
P31
PLU.22 PS-SD
Choice 0: Prog means to be programme,
Choice 1: Skip means skiped in programme
Class PLU 13: class that it belongs to
PLU 22: Sale date print
Attached: PLU.27: Sale date data
42
Menus
Menu Prompt
Instructions
P31
PLU.23 PS-ST
P31
PLU.24 PS-PD
P31
PLU.25 PS-PT
P31
PLU.26 PS-UD
P31
PLU.32 DF-U
P31
PLU.33 DF-D
P31
PLU.36 DA-S0
Remarks
State
PLU 23: Sale time print
Attached: PLU.28: Sale time data
PLU 24: Packing date print
Attached: PLU.29: Packing date print
PLU 25: Packing time print
Attached: PLU.30: Packing time data
PLU 26: Shelf date print
Attached: PLU.31: Shelf date data
PLU 32: Manual discount upperlimit
Attached: PLU.34
PLU 33: Manual discount lower limit
Attached: PLU.35
PLU 36: Customize 0 of auto discount
Attached: PLU.37-PLU.55
P32
DTAss SkFPLU PLU F-Prog skip step setting
P33
DTAss
The same as P31
P33
Delete Delete data of the scale
Validate code is needed to enter: 9958.
DEL.01
Dept Delete1: Dept.
When entering to delete, system would request
P33
DEL.02
Class Delete2: Class
to input 2 numbers which mean the start
P33
DEL.03
PLU Delete3: PLU
number and the end number of the data to
P33
DEL.04
Unit
delete. If the end number is 0, only data of the
P33
DEL.05 BCode Delete5: Barcode
start number would be deleted. If the number is
P33
DEL.06 PSets Delete6: Print format
not 0 and it’s less than start number, no data
P33
DEL.07
would be deleted.
P4
Sales Delete7: Salesman
Commu
P41
Delete4: Unit
Communication setting
Commu U-Disk Load and save of data in USB flash disk
P42
Commu Ethnet Not real-time Download from Ethernet
P43
Commu RS-232 RS232communication
P44
Commu USlave USB slave communication
P44
Commu
P5
PTR
HWAss
P51
Hardware assistant setting
Admin password is required to enter
administrator’s password: 200806
HWAss Set-PW Hardware: setting password
P511 HWAss Set-PW Admin
: Admin password
P512 HWAss Set-PW Sale
: Sale password
P513 HWAss Set-PW Prog
: Prog password
P514 HWAss Set-PW Account
: Account password
P515 HWAss Set-PW Drawer
: Drawer password
P52
Not Open
Ethernet printer communication
Input same passwords 2 times to complete
amendment of password.
HWAss TMS-DFHardware: Recover factory default
P521 HWAss TMS-DFFac-Set
P522 HWAss TMS-DF
Base-DT
default)
P523 HWAss TMS-DFEraseDT
P524 HWAss TMS-DF
: Scale parameter(P1x)
: Default working data(P2x
Fac-All
: All working data(P2x)
: All parameters and
The interface that requires to input validate
code would be shown before default setting.
Input 9958 to finish setting.
data(P2x)
43
5.3 The Edit of All Parts in TMSet
5.3.1 Time Programme
Example 5-1 Time Programme
Operations
Keys
『Sale Idle』
Enter programme 【Prog】
Enter TMSet
【1】
Enter time
【1】
programme
Input current time
by number key
Tare
0.000
P1
P11
2008
Year
Display
Change/
U.Price
0.00
Weight/
Single/
Count
Total
0.000
0.00
TMSet
TMSet
Time
05 19
20 21
51 W-1
Month Day Hour Minute Second Week
……
Save time
【Amend】 P11
Return to sale
【Sale】 0.000
TMSet
0.000
Time
0.00
0.00
Remarks
〖Sale〗,〖Sum〗on.
〖Prog〗 on.
W-0 means Sunday, W-1
means Monday, and the like.
Cursor indicates current
editing object. And using
【←】
【→】 could move the
position of cursor.
Save to the scale.
〖Sale〗, 〖Sum〗on.
5.3.2 Programme of Spec Parameters
Example 5-2 Programme of Spec parameters
Operations
『Sale Idle』
Enter programme
Enter TMSet
Enter Spec
Change to 2
Enter Spec002
Change to 77
Choose steps directly
Input step 40
Confirm step
Change to 99
Save and exit
Return to sale
Display
Keys
Remarks
Weight/ Change/
Single/
Tare
Count
U.Price
Total
0.000 0.000
0.00
0.00
〖Sale〗, 〖Sum〗on.
P1 TMSet
【Prog】
〖Prog〗on.
P11 TMSet
Time
【1】
P12 SP.000
1
1
【2】
Spec No. Origin Set Current Set
P12 SP.000
1
2
【2】
Using【】
【】 can only
0
0
get to amend items in Spec
【】【】 P12 SP.002
amend level 0.
P12 SP.002
0
77
【7】【7】
Input
1-1
0
【×】
The input number of step
must be in Spec amend
Input
1-1
40
【4】【0】
level 0 or 1. If not, the step
cannot be reached.
0
0
【Confirm】 P12 SP.040
P12 SP.040
0
99
【9】【9】
P12 TMSet
Spec
【Amend】
0.000 0.000
0.00
0.00
【Sale】
〖Sale〗, 〖Sum〗on.
N o t e 1 The way it programmes is the same as the way in Fast-Prog of Spec Parameters in page 19, except
the way it enters programme page.
N o t e 2 Please refer to Definitions of Spec data parameters in page 73 for definitions of all items of Spec
44
data parameters.
5.3.3 Programme of Text Parameters
Example 5-3 Programme of Text Parameters
Operations
Keys
『Sale Idle』
Enter programme
Enter TMSet
【Prog】
【1】
Enter String
【3】
Switch to device name
Switch to store name
Enter editing
【→】
【←】
【Confirm】
Clear original text
【End】
Switch to EN-2
Save editing text
Return to sale mode
【Switch】
【Amend】
【Sale】
Tare
0.000
P1
P11
P13
Display
Remarks
Weight/ Change/ Single/
Count U.Price
Total
0.000
0.00
0.00 〖Sale〗, 〖Sum〗on.
TMSet
〖Prog〗on.
TMSet
Time
ST.000 ShopN Push-OK
ST.000 is store name.
String No. String Info
P13 ST.001
P13 ST.000
EN-1
0
EN-1
ScaleN Push-OK ST.001 is device name.
ShopN Push-OK
In view of have original
text, Suggesting users
press 【 End 】 before
editing to clear former
text.. If modify on
original literal, use【】
【】to move cursor to
target position
0
EN-2
0
P13 PLU.14
0.000 0.000
Name
0.00
0
OK-Edit Save to the scale.
0.00 〖Sale〗, 〖Sum〗 on.
N o t e 1 Please refer to 7.3 Definitions of String data paremeters for definitions of each text parameter.
5.3.4 Programme of PLU Shortcut Keys
Example 5-4 Programme of PLU Shortcut Keys
Display
Remarks
Weight/ Change/ Single/
Tare
Count U.Price Total
0.000 0.000
0.00
0.00 〖Sale〗, 〖Sum〗 on.
『Sale Idle』
Enter programme
P1 TMSet
【Prog】
〖Prog〗on.
Enter TMSet
P11 TMSet
Time
【1】
Enter PLU shortcut key
P14 scPLU
-----------【4】
Set SC1
P14 scPLU
0-01
0
【SC1】
Input PLU number
P14 scPLU
0-01
10
【1】【0】
Confirm input
------------ Save to temporary buffer.
【Confirm】 P14 scPLU
Set SC2
P14 scPLU
0-02
0
【SC2】
Input PLU number
P14 scPLU
0-02
11
【1】【1】
Confirm input
------------ Save to temporary buffer.
【Confirm】 P14 scPLU
Set Shift+SC1
1-01
0
【Shift】
【SC1】P14 scPLU
Input PLU number 【1】【0】【0】 P14 scPLU
1-01
100
Operations
Keys
45
【Confirm】
Confirm input
P14
scPLU
【Amend】 P14 TMSet
0.000 0.000
【Sale】
Save editing text
Return to sale mode
------
scPLU
0.00
Save to temporary buffer.
The last confirm can be
------skipped. Press 【Amend】
directly.
Save to the scale.
0.00 〖Sale〗, 〖Sum〗on.
N o t e 1 The way it programmes is the same as the way of Example 3-2 and Example 3-3 in page 18, except
the way it enters programme interface.
5.3.5 Programme of Fuction Shortcut Keys
Example 5-5 Programme of Fuction Shortcut Keys
Operations
『Sale Idle』
Enter programme
Enter TMSet
Enter Fuction shortcut
Set SC1
Input Fuction number
Save editing text
Return to sale mode
Display
Keys
Remarks
Weight/ Change/ Single/
Tare
Count U.Price Total
0.000 0.000
0.00
0.00 〖Sale〗, 〖Sum〗 on.
P1 TMSet
【Prog】
〖Prog〗on.
P11 TMSet
Time
【1】
P15 scFuc
-----------【5】
P15 scFuc
0-01
0
【SC1】
P15 scFuc
1
76
Fuction “Custom Info 1”=76
【7】【6】
scFuc
Save to the scale.
【Amend】 P15 TMSet
0.000 0.000
0.00
0.00 〖Sale〗, 〖Sum〗on.
【Sale】
N o t e 1 Please refer to 7.4 Definitions of Shortcut Function Key for details
5.4 The Edit of All Parts in DTSet
5.4.1 Department Programme
The department (Dept. for short) is the largest category in sales statistics. And it’s marked with number from 1 to
99 and the corresponding meanings are shown below:
Number
1
2
8
9
10~99
Use
System Dept.
System Dept.
System Dept.
Default Dept.
User Dept.
Instructions
Not edited weight Dept.
Not edited count Dept.
Error Dept.
Default Dept. for Class editing
Dept. that users can edit
Example 5-6 Department Programme
Operations
Keys
『Sale Idle』
Enter programme
Enter DTSet
【Prog】
【2】
Enter Dept. programme
【1】
Enter number 10
Next
【1】【0】
【→】
Tare
0.000
P1
P21
P21
P21
P21
Display
Remarks
Weight/ Change/ Single/
Count U.Price Total
0.000
0.00
0.00 〖Sale〗, 〖Sum〗 on.
TMSet
〖Prog〗 on.
DTSet
Dept
DPT.00 NoSet
0
Step No. Step Info Object
DPT.00 NoSet
10
DPT.01 Name OK-Edit
46
Edit department name
Save editing data
Return to sale mode
【Amend】 P21 DPT.00
0.000 0.000
【Sale】
NoSet
0.00
0
0.00
Department names would
usually not be printed. And they
are always used for
management in PC. So editing
their names is of little meaning.
Here we skip it off.
Continue to edit other
〖Sale〗, 〖Sum〗 on.
5.4.2 Class Programme
Class is the second largest category in sales statistics. And it is marked with number from 1 to 99 and the
corresponding meanings are shown below:
Number
1
2
8
9
10~99
Dept.
1
2
8
9
Use
System Class
System Class
System Class
Default Class
User Class
Instructions
Not edited weight Class
Not edited count Class
Error Class
Default Class for PLU editing
Class that users can edit
Example 5-7 Class Programme
Operations
Keys
Tare
『Sale Idle』
Enter programme
Enter DTSet
【Prog】
【2】
Enter class programme
【2】
Input class number 10
Next
【1】【0】
【→】
P22
P22
【→】
P22
【1】【0】
P22
0.000
P1
P21
P22
Edit class name
Next
Input department
number 10
Save editing class
Return to sale mode
Display
Remarks
Weight/ Change/ Single/
Count U.Price Total
0.000
0.00
0.00 〖Sale〗, 〖Sum〗 on.
TMSet
〖Prog〗 on.
DTSet
Dept
CLS.00 NoSet
0
Step No. Step Info Object
CLS.00 NoSet
10
CLS.01 Name OK-Edit
Class names would usually not
be printed. And they are always
used for management in PC. So
editing their names is of little
meaning. Here we skip it off.
Department that the class
CLS.02
Dept
0
belongs to. And the department
must exist.
CLS.02
Dept
10
【Amend】 P22 CLS.00
0.000 0.000
【Sale】
NoSet
0.00
0
0.00
Continue to edit other classes.
〖Sale〗, 〖Sum〗 on.
5.4.3 PLU Programme
Price-LookUp is information cell for goods sale. Serial number of PLU, as the only sign of scale store PLU, is
defined by user to correspond to actual goods. Remark number, as the number defined by users or the serial
number of actual goods, is often printed as barcode. All the serial numbers which can be edited by users are from
47
10 to 9999999. And special serial numbers are corresponding to the meanings shown below:
Internal
Number
1
2
3
10~5999
Number
Class
Use
Instructions
9999999
9999998
9999997
1~9999996
1
2
3
System PLU
System PLU
System PLU
User PLU
Not edited weight PLU
Not edited count PLU
Service charge PLU
PLU for users to edit
Example 5-8 PLU Programme
Display
Operations
Keys
Weight/ Change/
Tare
Count
U.Price
0.000 0.000
0.00
『Sale Idle』
Enter Prog
P1 TMSet
【Prog】
Enter DTSet
P21 DTSet
Dept
【2】
P23 PLU.00
Not Set
PLU Prog
【3】
Step No. Step Info
PLU Number 【1】【0】 P23 PLU.00
Not Set
Go to Next
P23 PLU.01
ICode
【】
Input
Item-Code
90001
P23 PLU.01
ICode
Go to Next
【】
P23 PLU.03
Unit
Set as weight
PLU
【1】
P23 PLU.03
Unit
Go to Next
【】
P23 PLU.04
Price
Set U.Price 【3】
【0】
【00】P23 PLU.04
Price
Go to Next
Set cost
Go to Next
【】
P23 PLU.05
Cost
【2】
【4】
【00】P23 PLU.05
Cost
【】
P23 PLU.06
Tare
Single/
Total
0.00
Remarks
〖Sale〗,〖Sum〗on.
〖Prog〗 on.
0
〖Prog〗on.
Object
10
Number are between 1~9999999
0
ICode is Item-Code, which is usually
printed as part of letters on barcode
print. If the number of barcodes is
90001
default 2/5 or other custom numbers,
ICode are printed as a part of barcodes.
Please see details in chapter Barcode.
0
【0】,【1】: default weight unit;
【2】: default count unit;
【3】: kg weight unit;
【4】: g weight unit;
【5】: ton weight unit;
【6】: lb weight unit;
1
【7】: 500g weight unit;
【8】: 100g weight unit;
Please see details in unit chapter.
Default weight unit mean the unit used
for display. And it is suggested for
weight PLU.
0.00
Preset U.Price in sale. Don't have to
30.00 input it. Users can temporarily input it
in sale.
0.00
The cost is used to calculate the profits.
24.00
Don’t have to input it.
0.000
48
Set Tare
Go to Next
Set name
Clear Original
Text
P
ork
Input number
2
Save edited
text
Go to next
【5】
P23 PLU.06
P23 PLU.14
【】
0
【Confirm】 En-1
【End】
Tare
Name
In consideration of there was a text, we
suggest users press 【End】 before
editing. If editing in the original text,
users could use【】
【】 to move the
position of cursor.
EN-1
0
【Shift】
【p/P】EN-1
【o/O】【r/R】
EN-1
【k/K】
EN-1
【-】
1
P
4
rk
5
k-
6
-2
【2】
En-1
【Amend】 P23 PLU.14
【】
P23 PLU.26
When transferring PLU, it’s preset tare.
Don’t have to input it.
OK-Edit Input the names of goods.
0.005
Name
PS-UD
This 【Amend】 is to save text edit in
buffers instead of PLU. Please pay
OK-Edit attention: If users need save it in PLU,
users need to press【Amend】 again as
the step below.
0
If to print the shelf life date
Print shelf date
【1】
P23 PLU.26
PS-UD
1
Go to next
【】
P23 PLU.31
PC-UD
0
Input shelf
days
【】
P23 PLU.31
PC-UD
3
Not Set
0
0.00
0.00
……
P23
Save edited
【Amend】 P23 PLU.00
PLU
Return to sale 【Sale】 0.000 0.000
0: Don't print PLU 31 invalid
1: Print. Continiune to set shelf days in
PLU.31
Shelf days. 0 means intraday valid,
followed like this.
If all cargo for one scale use same shelf
days, use Spec105 & Spec106
If other steps are still to be edited, users
can use 【】【】 to switch steps.
PLU10 is saved.
〖Sale〗,〖Sum〗 on
N o t e 1 Except the parts which have been instructed, meaning of the other words are listed List of
Programme Interface in page 46
N o t e 2 The way it programmes is the same as the way Fast-Prog of Example 3-1 in page 16, except the way
it enters programme page.
N o t e 3 xx is not continuous when users press【】and【】to select the programme content. There are two
reasons. First reason is that the content in this part is meaningless. For example, tare is not present in
count PLU programme. The second reason is that the content in that part is seldom used and has been
set as non-programme content (Skip) in P31 and P32. Users could change that setting for personel
usage and please refer to corresponding chapters for details.
5.4.4 Unit Programme
Unit is the basis of sale price. The scale has shielded parts of functions in consideration that edit of units may
49
cause unnecessary trouble. The 8 units edited when when the scale is released from factory are shown as below:
Number
1
2
3
4
5
6
7
8
9~19
20~99
Instructions
Default weight unit
Default count unit
Kg unit
g unit
ton unit
lb unit
500g unit
100g unit
System reserved unit
Unit for user to add
N o t e 1 Default weight unit is the measure unit of the scale.
Example 5-9 Unit Programme
Operations
『Sale Idle』
Enter programme
Enter DTSet
Enter unit
programme
Enter number 30
Next
Set unit name
Clear orginal text
Save editting text
Save editing unit
Return to sale
mode
Keys
【Prog】
【2】
【4】
Tare
0.000
P1
P21
P24
【3】【0】
【→】
【Confirm】
【End】
【Amend】
【Amend】
P24
P24
En-1
En-1
P24
P24
【Slae】
0.000
Display
Remarks
Weight/ Change/ Single/
Count
U.Price
Total
0.000
0.00
0.00
〖Sale〗, 〖Sum〗 on.
TMSet
〖Prog〗 on.
DTSet
Dept
UNT.00
NoSet
0
Step No. Step Info Object
UNT.00
NoSet
30
UNT.01
Name
OK-Edit
0
Unit name printed as unitage
0
UNT.01
Name
OK-Edit Save unit to buffer
UNT.00
NoSet
0
Go on edit other unit
0.000
0.00
0.00
〖Sale〗, 〖Sum〗 on.
5.4.5 Barcode Programme
Barcodes have different meanings in various applications and coding systems. Some barcodes are already edited
when the scale is released from factory. Users could choose some barcodes from them to use or edit the barcode
for themselves.
Number
1~9
Use
Factory Default
10~99
User’s barcode
Instructions
Already edited when the scale is released from factory
User cannot edit them.
Barcode that can be edited by users
Example 5-10 Barcode Programme
Operations
Keys
『Sale Idle』
Enter programme
【Prog】
Display
Remarks
Weight/ Change/ Single/
Tare
Count U.Price Total
0.000 0.000
0.00
0.00 〖Sale〗, 〖Sum〗 on.
P1 TMSet
〖Prog〗 on.
50
Enter DTSet
【2】
Enter barcode
【5】
Enter number 10
Next
【1】【0】
【→】
P21
DTSet
Dept
BAR.00 NoSet
0
P25
Step No. Step Info Object
P25 BAR.00 NoSet
10
P25 BAR.01 Name OK-Edit
Edit barcode names
Next
【→】
P25 BAR.02
Type
0
Next
【→】
P25 BAR.03 Check
0
Next
Next
Next
【→】
【→】
【→】
P25 BAR.04 NCon1
0
P25 BAR.05 Ncon2
0
P25 BAR.06 Des OK-Edit
Edit the descriptions of
barcodes
Save editing barcode
Return to sale mode
P25
【Amend】 P25 BAR.00 NoSet
0.000 0.000
0.00
【Sale】
0
0.00
Barcode names would usually not
be printed. And they are always
used for management in PC. So
editing their names is of little
meaning. Here we skip it off.
See Table 5-1 List of Barcode
Types.
See Table 5-2 Check Digit of
Barcode.
It could be used as fixed number
in barcode data.
Barcode descriptions should be
in exact appointed format and
edit a text with the length of 24.
Otherwise the format would be
invalid when it’s printed.
Please refer to the content of
Table 5-3 Descriptions of
Barcode Data Items and Table
5-4 Factory Default Barcode.
Continue to edit other barcodes.
〖Sale〗, 〖Sum〗 on.
Table 5-1 List of Barcode Types
Barcode formats
0
1
2
3
4
5
6
7
Instruction
Default
EAN13
EAN8
UPC A
UPC E
EAN-128
Code-128C
ITF-25
Valid number digit (suggest)
12
7
11
6
Even or Odd with Checksum
Even or Odd with Checksum
Even or Odd with Checksum
N o t e 1 When select default, it will auto select the most reasonable barcode format according to valid
number digit
N o t e 2 When print EAN-128, Code-128C or ITF-25, if length of number is odd number, it will auto add one
checksum at the end. The arithmetic is same as EAN/UPC checksum
51
Table 5-2 Check Digit of Barcode
Check ways
0
1
2
3
All checks
End Check
Middle Check
Not check
N o t e 1 Check digit of barcode for barcode formats is just an advice for the scale. The scale would process
the check based on the selected barcode format. For example, EAN13 is verified by End Check no
matter which kind of check is selected.
Table 5-3 Descriptions of Barcode Data Items
Items
Restrictions
A
B
C
D
E
F
G
H
I
J
K
L
M
N
L
P
Q
R
S
Instructions
Not print
Spec Flag
Constant Num 1
Constant Num 2
PLU Number
PLU Item-Code
PLU Index
PLU Flag
PLU real U.Price
PLU count/weight
PLU T.Price
Sale T.Price
Sale T.Count
Sale T.Weight
Add-up Times
Sales man number
Sale date: year
Sale date: month
Sale date: date
Print length 0~9
Data Source
A~Z
Display Length
0~9
Data Shift
0~9
Move to right 0~9 digits
0~3
0: not print
1: truncation print
2: fill in with character 0
3: fill in with character 9
Overflow
management
Table 5-4 Factory Default Barcode
Number
Name
Descriptions
1
B-Item 1
B201E500K500A000A000A000
2
B-Item 2
B201F500K500A000A000A000
3
B-Item 3
F700K500A000A000A000A000
Use
Instructions
2 digits Spec Flag,
Item
5 digits PLU Number,
barcode
5 digits PLU T.Price.
2 digits Spec Flag,
Item
5 digits PLU Item-Code,
barcode
5 digits PLU T.Price.
Item
7 digits PLU Item-Code,
barcode
5 digits PLU T.Price.
52
4
B-Item 4
B201E400K600A000A000A000
Item
barcode
5
B-Item 5
B201F400K600A000A000A000
Item
barcode
6
B-Item 6
F600K600A000A000A000A000
7
B-Sum 1
B701L500A000A000A000A000
8
B-Sum 2
B601L600A000A000A000A000
9
B-Sum 3
B501L700A000A000A000A000
Item
barcode
Total
barcode
Total
barcode
Total
barcode
2 digits Spec Flag,
4 digits PLU Number,
6 digits PLU T.Price.
2 digits Spec Flag,
4 digits PLU Item-Code,
6 digits PLU T.Price.
6 digits PLU Item-Code,
6 digits PLU T.Price.
7 digits Spec Flag,
5 digits Sale T.Price.
6 digits Spec Flag,
6 digits Sale T.Price.
5 digits Spec Flag,
7 digits Sale T.Price.
5.4.6 Print Formats Programme
Number
1~9
10~39
Use
Factory default
User’s print format
Instructions
Already edited when the scale is released from factory
Print format can be edited by users
Different print formats are needed in various applications. Some print types are already edited when the scale
is released from factory. Users could choose some formats from them or edit the format for themselves. It’s very
hard to edit print format on the scale. Suggest users do not edit print format on the scale.
This chapter would not offer any examples about print formats edit. Users should use the software on PC to
edit print formats or write down demands and send them to us. We will edit the print format you need.
Table 5-5 Factory Default Print Formats
No.
1
2
3
4
5
6
7
8
9
Format
Item Label
Item Label
Item Label
Total Label
Total Label
Total Label
Receipt
Receipt
Receipt
Gap Paper
58mm*40mm
40mm*30mm
58mm*30mm
58mm*40mm
40mm*30mm
58mm*30mm
Plain Paper
58mm
40mm
58mm
58mm
40mm
58mm
58mm
40mm
48mm
N o t e 1 If users use gap paper in size of 58mm*30mm, set the value of Spec000 to 1, Spec001 to 4.
N o t e 2 If users use gap paper in size of 40mm*30mm, set the value of Spec000 to 2, Spec005 to 5.
N o t e 3 If users use gap paper in size of 58mm*30mm, set the value of Spec000 to 3, Spec005 to 6.
N o t e 4 If users use plain paper in width of 58mm, set the value of Spec000 and Spec005 to 7
N o t e 5 If users use plain paper in width of 40mm, set the value of Spec000 and Spec005 to 8.
N o t e 6 If users use plain paper in width of 48mm, set the value of Spec000 and Spec005 to 9.
Table 5-6 Factory Default Print Formats for cash register scale
No.
1
Format
Receipt
Gap Paper
48mm
Plain Paper
Print PLU number
53
2
3
4
8
9
Receipt
Receipt
Receipt
List
List
48mm
48mm
48mm
48mm
48mm
Print number
New Line mode with Name
Large Font Mode
Cookroom Use List
Cookroom Use List, Large Font Mode
N o t e 1 User can use format 8 or 9, when remote printer is used as a cookroom printer.
If user really need to edit print format on the scale, please refer to 5.2.3 List of Programme Interface of P26
print format, following table are example to user refer:
Table 5-7 Print format: Print-item instruction
Print Item
Name
Sort
Length
Number Range
Instruction
Item No.
Number
Sign 1
Flag1
Number
1
0~99
Unique number with order
Code
1
Sign 2
Flag2
Code
1
Sign 3
Flag3
Code
1
Refer to later table
0: Not Print
1: Print
2: By-weight PLU print
3: By-count PLU print
4: Temporary PLU print
5: Tared PLU print
6: Free PLU print
Print State
Print
Code
1
0~255
7: Print with sale date
8: Print with packing date
9: Print with shelf date
10: Not 1pcs PLU print
11: Item service charge print
12: Service charge print
13: Taxed PLU print
Other: not defined
Angle
Angle
Code
1
0~3
Clockwise rotation: Angle*90
Snap to grid
Grid
Code
1
0~9
1~9: 9 position, 0: default
Font
CFont
Code
1
X Position
S-X
Y Positon
S-Y
Width
L-X
Height
L-Y
Coordinate
Coordinate
3~5
Version before V2.03
0~9
Version after V2.03 and V2.03
2
0 ~ 65535
2
0 ~ 65535
2
0 ~ 65535
2
0 ~ 65535
Start coordinate for print area
Height and width for print area
Table 5-8 Print format: Print-item code
Flag1
Code
Content
0
Barcode
1
Item Info
Flag2
Code
Flag3
Content
0
Readable
1
Not Readable
Code
Content
Flag3 blank means no effect.
Followed are the same
0
X
0
Name
1
1
1
Amount
2
2
2
Tare
If Flag2=3, it means print
the information for the third
3
3
3
First Unit Price
4
4
4
Payable Unit Price
‘X’ in Flag2 means print all
cargo in turn.
accumulate cargo’s
54
2
Sale Info
5
5
5
Price
6
6
6
PLU Number
7
7
7
Class Number
8
8
8
Dept. Number
9
9
9
Index
10
10
10
Item-Code
11
11
11
Sale Date
12
12
12
Sale Time
13
13
13
Package Date
14
14
14
Package Time
15
15
15
Shelf Date
…
…
16
Text 1
18
18
17
Text 2
19
19
18
Text 3
20
20
19
Text 4
21
21
20
Text 5
22
22
21
Text 6
23
23
22
Text 7
24
24
23
Gross
25
25
24
Measure Unit
26
26
25
Price Unit
27
27
26
Price without Tax
28
28
27
Tax
29
29
28
Item Service Fee
30
30
29
Tax Rate
31
31
30
PLU No and Name
0
Store Name
1
Device Name
2
Device Number
3
Print Date
4
Print Time
5
Add-up Times
6
Total Count
7
Total Weight
8
Total Price
9
Payment
10
Change
11
Rounding Money
12
Unit of Weight
13
Unit of Weight Price
14
Unit of Count
15
Unit of Count Price
16
Unit of Money
17
Device Postil 1
18
Device Postil 2
19
Device Postil 3
20
Device Postil 4
21
Device Postil 5
55
22
Device Postil 6
23
Device Postil 7
24
Device Postil 8
25
FID
0~8
Least Digital
26
SID
0~8
Least Digital
27
Net Price
28
Gross Price
29
Money of Discount and
Rounding
30
3
4
5
Salesman No.
31
Salesman Name
32
Total Price without Tax
33
Total Tax
34
Waiter Number
35
Waiter Name
36
Text of Item Service Fee
37
Text of Service Fee
38
Industry Mark
39
Reserved 4
40
Reserved 5
41
Reserved 6
42
Reserved 7
43
Reserved 8
44
Service Fee
45
Tax of Service Fee
46
Service Fee without Tax
47
Buffer Number
Const Text 0~15
Outline
Border
Partition
0~15
1~24
1~24
0
Area Flag
1
Page Print
2
Line Print
Flag2 is text series number
Flag2 is outline boarder
thickness
0 ~32
0mm~32mm
5.4.7 Salesman Programme
Example 5-11 Salesman Programme
Operations
Keys
『Sale Idle』
Enter programme
【Prog】
Enter DTSet
【2】
Enter salesman programme 【7】
Enter salesman 10
【1】【0】
Next
【→】
Edit salesman name
Tare
0.000
P1
P21
P27
P27
P27
Display
Remarks
Weight/ Change/ Single/
Count U.Price Total
0.000
0.00
0.00 〖Sale〗, 〖Sum〗 on.
TMSet
〖Prog〗 on.
Step No. Step Info Object
DTSet
Dept
SAL.00 NoSet
0
SAL.00 NoSet
10
SAL.01 Name OK-Edit
Process is omitted.
56
Next
P27 SAL.02
【→】
Edit salesman password
Save editing salesman 【Amend】 P27 SAL.00
Return to sale mode
【Sale】 0.000 0.000
Pass
0
NoSet
0.00
0
0.00
Continue to edit other salesmen.
〖Sale〗, 〖Sum〗 on.
N o t e 1 Number 1~99 is the content for users to edit.
5.5 Assistant Data Programme
5.5.1 Steps Select of PLU Programme
Example 5-12 Steps Select of PLU Programme
Operations
『Sale Idle』
Enter programme
Enter DTAss
Enter step selection
of PLU prog
Select step: ICode
Select step: Index Barcode
Display
Keys
Weight/ Change/
Tare
Count U.Price
0.000 0.000
0.00
【Prog】 P1 TMSet
P31 DTSet Sk-PLU
【3】
P31 PLU.00 NoSet
【1】
PLU
Step
Step
Info
P31 PLU.01 ICode
【→】
【→】
P31
Enable step: Index Barcode 【↓】
P31
Select step: Unit
P31
【→】
Select step: U.Price
P31
【→】
Select step: Cost
P31
【→】
Disable step: Cost
P31
【↓】
Save steps selection
【Amend】 P31
Return to sale mode
【Sale】 0.000
PLU.02
Index
PLU.02 Index
PLU.03
Unit
PLU.04
Price
PLU.05
Cost
PLU.05
Cost
DTSet Sk-PLU
0.000
0.00
Remarks
Single/
Total
0.00 〖Sale〗, 〖Sum〗 on.
〖Prog〗 on.
Prog 0
Prog or
Skip
Prog 0
Skip
Prog
Prog
Prog
Prog
Skip
0
0.00
Default index number is not
activated.
0 Amend to activation.
0
0
0 Default cost is activated.
1 Amend to not activated.
1
〖Sale〗, 〖Sum〗 on.
N o t e 1 The steps above activate steps Index Barcode and shield steps Cost.And then there is a step to input
index in the programme of P23, but no step to input cost. Select Prog or Skip by pressing【0】\【1】 or
【↑】【
\ ↓】. If Prog is selected, the step is in the programme. If Skip is selected, the step is skiped and
not in programme.
N o t e 2 Amended content would be in effect only in PLU programme and not effective in fast-prog.
5.5.2 Steps Select of PLU Fast Programme
Example 5-13 Steps Select of PLU Fast Programme
Operations
『Sale Idle』
Enter programme
Enter DTAss
Enter step selection of
Display
Keys
Remarks
Weight/ Change/ Single/
Tare
Count U.Price Total
0.000 0.000
0.00
0.00 〖Sale〗, 〖Sum〗 on.
【Prog】 P1 TMSet
〖Prog〗 on.
P31 DTSet Sk-PLU
【3】
P32 PLU.00 NoSet Prog 0
【2】
57
PLU fast prog
Select step: ICode
【→】
P32
PLU
Step
PLU.01
Select step: Index
【→】
P32
PLU.02
Enable step: Index
Select step: Unit
Select step: U.Price
Select step: Cost
Disable step: Cost
Save steps selection
Return to sale mode
P32
【↓】
P32
【→】
P32
【→】
P32
【→】
P32
【↓】
【Amend】 P32
【Sale】 0.000
Step Prog or
Info
Skip
ICode Prog 0
Index
PLU.02 Index
PLU.03
Unit
PLU.04
Price
PLU.05
Cost
PLU.05
Cost
DTSet Sk-PLU
0.000
0.00
Skip
Prog
Prog
Prog
Prog
Skip
0
0.00
Default index number is not
activated.
0 Amend to activation.
0
0
0 Default cost is activated.
1 Amend to not activated.
1
〖Sale〗, 〖Sum〗 on.
N o t e 1 The processes are the same as Example 5-12 only if amended contents only work in PLU fast-prog
instead of PLU programme.
5.5.3 Delete Sale Data
When entering the interfaces of delete, users would be requested to receive validate code. Validate code is
9958. Confirm and enter delete process.
Example 5-14 Delete PLU20~30
Display
Operations
Keys
Remarks
Weight/ Change/ Single/
Tare
Count U.Price Total
0.000 0.000
0.00
0.00 〖Sale〗, 〖Sum〗 on.
『Sale Idle』
Enter programme
P1 TMSet
【Prog】
〖Prog〗 on.
Enter DTAss
P31 DTSet Sk-PLU
【3】
Enter interface of delete
Input
Code
0
Request input validate code .
【3】
【9】
【9】
【5】
Input validate code
Input
Code
9958
【8】
【1】: Dept.,
【2】: Class,
【3】: PLU,
Confirm validate code 【Confirm】 P331 DTSet Delete Dept 【4】: Unit,
【5】: Barcode,
【6】: Print Format
【7】: Salesman.
Select to delete PLU
Input
2-1
0
【3】
【2】【0】
Input start number
Input
2–2
0
【Confirm】
【3】【0】
Input end number
P333 DTSet Delete PLU
【Confirm】
Return to sale mode
0.00
0.00 〖Sale〗, 〖Sum〗 on.
【Sale】 0.000 0.000
N o t e 1 Once confirming to delete object, users shall be requested to input 2 numbers. And system would
delete data objects in the range between the two numbers. If the 2nd number is 0, the object appointed
by 1st number is deleted. If 2nd number is less than 1st number, no object is deleted.
58
5.6 Communication and Data Update
5.6.1 Operations of files in USB flash Disk.
Data edited on PC could transfer by USB flash disk.
The software would create a file in the directory of JHSCALE when exporting a file to USB flash disk.
If users export auto-update file, the form of file is A_xxx.TMS. If the scale has set USB flash disk
auto-update (factory default setting), after switch on, the scale would update the data when system detects the file
in USB flash disk
In P41, press【×】 to select auto-update file A_xxx.TMS, or input number to select numbered files from
A_000.TMS to A_999.TMS (The number is file serial number ). Press【Confirm】to load file data and update the
information in the scale. Or press 【Amend】 to save scale information to appointed file.
Example 5-13 Load Files in USB Flash Disk
Operations
Keys
Tare
Display
Weight/
Change/
Count
U.Price
0.000
0.00
TMSet
『Sale Idle』
Enter programme
【Prog】
0.000
P1
Enter Commu
【4】
P41
Commu
U-Disk
Enter operation of
USB flash disk
【1】
P41
Commu
U-Disk
Single/
Total
0.00
Remarks
〖Sale〗, 〖Sum〗 on.
〖Prog〗 on.
Make sure USB flash disk
exists.
000
Input number here to load
numbered file.
Appoint auto-update
P41
Commu
U-Disk
XXX Please make sure selected
【×】
file
files are in the directory
JHSCALE.
0
0
0
Dw-Data When operation finishes
Load files
【Confirm】 Number of Number of Number Working normally, the state change
Error Data Right Data of Bytes
State into finish.
Several seconds
0
…
…
Finish
Exit
P41
Commu
U-Disk
Press any key to quit.
【Confirm】
Return to sale mode 【Sale】
0.000
0.000
0.00
0.00
〖Sale〗, 〖Sum〗 on.
N o t e 1 If file is loading ends normally, system would change the state into Finish. Normally, the amount of
error commands should be 0.
N o t e 2 If system encounters with invalid files or other serious mistakes, change the state into Error.
N o t e 3 In the state of Finish or Error, press any key to exit. If users want to exit midway, press 【Cancel】.
Example 5-14 Save working data to Files in USB Flash Disk
Operations
『Sale Idle』
Enter programme
Enter Commu
Keys
【Prog】
【4】
Tare
0.000
P1
P41
Display
Weight/
Change/
Count
U.Price
0.000
0.00
TMSet
Commu
U-Disk
Remarks
Single/
Total
0.00 〖Sale〗, 〖Sum〗 on.
〖Prog〗 on.
Make sure USB flash disk
59
exists.
Enter operation of
USB flash disk
Appoint numbered
file
Save file
【1】
P41
Commu
U-Disk
000
【1】【2】
P41
Commu
U-Disk
012
0
0
0
Data
Sort
Data
Number
…
…
…
Finish
0.000
0.000
0.00
0.00
【Amend】
Several seconds
Exit
【Confirm】
Return to sale mode 【Sale】
Press 【 × 】 to select
auto-update file.
Up-Data When operation finishes
normally, the state change
Number of Working into finish.
Saved Data State
〖Sale〗, 〖Sum〗 on.
N o t e 1 Exporting data to files in USB flash disk may take a lot of time. Please wait.
N o t e 2 Press any key to exit when saving is ended. If users want to exit midway, press 【Cancel】.
Example 5-15 Save sale list to Files in USB Flash Disk
Operations
Keys
Tare
Display
Weight/
Change/
Count
U.Price
0.000
0.00
TMSet
『Sale Idle』
Enter programme
【Prog】
0.000
P1
Enter Commu
【4】
P41
Commu
U-Disk
【1】
P41
Commu
U-Disk
【1】【2】
P41
Commu
0
0
Data
Sort
Data
Number
…
…
0.000
0.000
Enter operation of
USB flash disk
Appoint numbered
file
Save file
【PLU】
Several seconds
Exit
【Confirm】
Return to sale mode 【Sale】
Remarks
Single/
Total
0.00 〖Sale〗, 〖Sum〗 on.
〖Prog〗 on.
Make sure USB flash disk
exists.
000
Press 【 × 】 to select
auto-update file.
【 PLU 】
save the
0
Up-Data un-uploaded sale list
【F-Prog】+【PLU】 save
Number of Working all un-deleted sale
list( PC software’s
Saved Data State
repeat upload)
…
Finish
U-Disk
012
0.00
0.00
〖Sale〗, 〖Sum〗 on.
N o t e 1 Exporting data to files in USB flash disk may take a lot of time. Please wait.
N o t e 2 Press any key to exit when saving is ended. If users want to exit midway, press 【Cancel】.
5.6.2 Ethernet Monitor Interface
Example 5-16 Enter Ethernet Monitor Interface
Operations
『Sale Idle』
Keys
Tare
0.000
Display
Weight/
Change/
Count
U.Price
0.000
0.00
Single/
Total
0.00
Remarks
〖Sale〗, 〖Sum〗 on.
60
Enter programme
【Prog】
P1
TMSet
Enter Commu
【4】
P41
Commu
U-Disk
0
0
0
Number of Number of Number
Error Data Right Data of Bytes
0
0
0
Data
Saved
Data area
number
data
Enter Ethernet
monitor interface
【2】
Transfer upload and
download
【×】
Exit
【Cancel】
P42
Commu
Ethernet
Return to sale mode
【Sale】
0.000
0.000
0.00
Dw-Data
Working
State
Up-Data
Working
State
0.00
〖Prog〗 on.
Make sure USB flash disk
exists.
Ethernet download
information and Stat.
information
Ethernet
upload
information and Stat.
information
Press any key to quit. If
want to exit in the
midway, press 【Cancel】
〖Sale〗, 〖Sum〗 on.
N o t e 1 This monitor interface is usually used when the scale is set to not update in real-time on Internet.
5.6.3 RS232 Communications
The interface is similar to ethernet monitor interface. If want to process RS232 communication, must
firstenter this interface
5.7 Hardware Assistant
5.7.1 Validate Code
On the purpose of preventing any misoperation in important operation interfaces, users are requested to input
validate code when entering these operation interfaces. The interface is shown below:
Input
Code
0
Validate code of this scale is 9958. When the scale requests to input validate code, users should first make
sure whether this operation interface is the one you intend to enter and understand the meaning of this operation.
Then input validate code and do operations.
5.7.2 Password
Password is the code to obtain the right to operate the scale. And there are 5 passwords in all.
Amend
steps
Types
Password type
Admin password
P511
Admin
P512
Sale
P513
Prog
P514
Account
Sale password
Program
password
Account
password
Permission
Hardware Assistant
(P51)
Sale interface
Prog interface
Account interface
Sale interface
Original
password
200806
Please keep it
safe if users
amend it.
0
Prog interface
0
Account interface
0
N o t e 1 That Password is 0 means no passwords needed. Users could set the password to be 0 when
canceling the password.
N o t e 2 Admin password is in a higher level than the other 4 passwords. Users do not need to input any
61
password to enter all interface if admin password is 0 , no matter whether the other passwords are 0.
N o t e 3 If users want to protect Prog interface or Account interface, first change the admin password other
than factory default, then set passwords of corresponding interfaces.
N o t e 4 Spec247’s password hold function can let the device remember the entered password, then, user do
not need to input the same password repeatedly
Example 5-17 Process of Amending Passwords
Display
Operations
Keys
Remarks
Weight/ Change/ Single/
Tare
Count U.Price Total
0.000 0.000
0.00
0.00 〖Sale〗, 〖Sum〗 on.
『Sale Idle』
Enter programme
P1 TMSet
【Prog】
〖Prog〗 on.
Enter hardware Assistant
Input
Pass
0
【5】
Display dashes is the as many
Input admin password
……
Input
Pass ------as input numbers.
Confirm password
P51 HwAss Set-PW
【Confirm】
Amend password
P511 HwAss Set-PW Admin
【1】
【1】: admin password
【2】: sale password
【3】: program password
Amend prog password
Input Pass-1
【3】
【4】: account password
【 5 】 : 【 open drawer 】
password
Input password
Input Pass-2 ------……【Confirm】
Repeat password
……【Confirm】 P513 HwAss Set-PW Prog
Return to sale mode
0.000 0.000
0.00
0.00 〖Sale〗, 〖Sum〗 on.
【Sale】
N o t e 1 Input password must match for two times so that password setting can be done.
5.7.3 Recover Factory Default Setting
Example 5-18 Process of Amending Passwords
Operations
『Sale Idle』
Enter programme
Enter hardware Assistant
Input admin password
Confirm password
Recovery factory default
Select the type to amend
Input validate code
Display
Keys
Remarks
Weight/ Change/ Single/
Tare
Count U.Price Total
0.000 0.000
0.00
0.00 〖Sale〗, 〖Sum〗 on.
P1 TMSet
【Prog】
〖Prog〗 on.
Input
Pass
0
【5】
Display dashes is the as many
……
Input
Pass ------as input numbers.
P51 HwAss Set-PW
P521 HwAss TMS-DF Fac-Set
【2】
Here are 4 recovery types:
【1】Scale parameter(P1x)
Input
Code
0 【2】default working data
【4】
【3】all working data(P2x)
【4】all parameters and data
Input
Code 9958
【9】
【9】
【5】
【8】
62
Confirm validate code
Return to sale mode
【Confirm】
【Sale】
P521 HwAss TMS-DF Fac-All
0.000 0.000
0.00
0.00 〖Sale〗, 〖Sum〗 on.
N o t e 1 Please pay attention to this. Execute recovery 1 or 4, and then passwords would change to factory
default.
N o t e 2 If user amend the Spec irrelevantly, it will make scale do not work regularly, suggest user to
executeP511
N o t e 3 P524 will let the scale recover to factory default state(all user’s data will be deleted)
63
6 Account Operations
6.1 List of Account Interfaces
Entering to Account interface, the scale would enter a calculate process, which first calculate sale records.
Then enter A1 select interface.
Table 6-1 List of Account Interfaces
Menus
A1
Menu Prompt
Total
Instructions
Total
Daily Total daily report
A12
Total
Monly Total monthly report
A13
Total
Qualy Total quarterly report
A14
Total
Manly Total manual report
A21
Dept
Daily Department daily report
A22
Dept
Monly Department monthly report
A23
Dept
Qualy Department quarterly report
A24
Dept
Manly Department manual report
Dept
A3
Department report
Class
Class report
A31
Class
Daily Class daily report
A32
Class
Monly Class monthly report
A33
Class
Qualy Class quarterly report
A34
Class
Manly Class manual report
PLU
PLU report
A4
A41
PLU
Daily PLU daily report
A42
PLU
Monly PLU monthly report
A43
PLU
Qualy PLU quarterly report
A44
PLU
Manly PLU manual report
Clear
Clear report
A5
A51
Clear
A52
Clear
A53
Clear
A54
A6
Manly Clear current manual report information
All
Clear all reports and records information
Stock Clear stock report information
Clear
SID
Stock
Clear SID information, reset to 0
Stock report
A61
Stock
Print
A62
Stock
Audit Stock update
A7
List
A71
A8
Stock print
Sale list report
List
Print
Sales
A81
State
Total report
A11
A2
Remarks
Sale list print
Salesman report
Sales
Daily Salesman daily report
A82
Sales
Monly Salesman monthly report
A83
Sales
Qualy Salesman quarterly report
A84
Sales
Manly Salesman manual report
6.2 Operations of Printing Report
6.2.1 Print Total Report
Total reports are divided into total daily report, total monthly report, total quarterly report and total manual
64
report.
Press "X" key to print the list of report information. The left side of list is report number, the right side of list
is time information. Number-0 is today's report, normally.
Input the number of report, press "Print" to print it.
Total manual report would take operation A51 as time point to divide the storage. The buffer zone delays a
position automatically when a report is cleared (That means: Buffer 31 records the information which was stored
in buffer 30. By analogy, buffer 1 record the information which was stored in buffer 0 and information stored in
buffer 0 is cleared. Then start accumulating in buffer 0. ).
Example 6-1 Print Daily Reports of Today and Yesterday
Display
Operations
Keys
Remarks
Weight/ Change/ Single/
Tare
Count U.Price Total
0.000 0.000
0.00
0.00 〖Sale〗, 〖Sum〗 on.
『Sale Idle』
Enter Account
A1
Total
【Account】
〖Account〗 on.
【1】: Total report
【2】: Dept. report
Enter total report
A11 Total
Daily
【1】
【3】: Class report
【4】: PLU report
【1】: Daily report
【2】: Monthly report
Enter total daily report
Input
2–1
0
【1】
【3】: Quarterly report
【4】: Manual report
Input start number 【0】
Input
2–2
0
Start from today.
【Confirm】
Input end number 【1】
…
…
…
End at yesterday.
【Confirm】 …
Print daily report of today. (错
A11 Total
Daily
0
误!未找到引用源。)
Print daily report of yesterday.
A11 Total
Daily
1
(错误!未找到引用源。)
A11 Total
Daily
End of print.
Return to sale mode
0.000 0.000
0.00
0.00 〖Sale〗, 〖Sum〗 on.
【Sale】
6.2.2 Print Department Report
The scale could print report of all departments. Operation steps are similar as Print Total Report.
Only the step to enter is different.
6.2.3 Print Class Report
The scale could print reports of all Classes. Operation steps are similar as Print Total Report.
Only the step to enter is different.
6.2.4 Print PLU Report
The scale could print reports of all Classes. Operation steps are similar as Print Total Report.
Only the step to enter is different.
65
6.3 Clear Report Information
6.3.1 Clear Report Information Manually
The information in manual reports would not be cleared automatically unless users enter A51 (clear current
manual report) interface to clear it. After this operation, manual reports of all departments, classes and PLU would
be cleared, and total manual report would delay its serial number.
Example 6-2 Clear Information in Manual Report
Operations
『Sale Idle』
Enter Account
Enter clear report
Clear manual report
Return to sale mode
Keys
Tare
0.000
A1
【Account】
A51
【5】
---【1】
A51
0.000
【Sale】
Display
Weight/ Change/
Count U.Price
0.000
0.00
Total
Clear Manly
---------Clear Manly
0.000
0.00
Remarks
Single/
Total
0.00 〖Sale〗, 〖Sum〗 on.
〖Account〗 on.
------- Wait a few seconds.
0.00 〖Sale〗, 〖Sum〗 on.
6.3.2 Clear All Reports and Records Information
Example 6-3 Clear All Reports and Records Information
Operations
Keys
Tare
『Sale Idle』
Enter Account
Enter clear report
Clear manual report
0.000
A1
A51
Display
Remarks
Weight/ Change/ Single/
Count U.Price Total
0.000
0.00
0.00 〖Sale〗, 〖Sum〗 on.
Total
〖Account〗 on.
Clear Manly
Input
Code
0 Input validate code.
【Account】
【5】
【2】
【9】【9】【5】
Input validate code
【8】
Confirm validate code 【Confirm】 -------A52 Clear
Return to sale mode
0.000 0.000
【Sale】
-----All
0.00
------0.00 〖Sale〗, 〖Sum〗 on.
N o t e 1 This operation would clear the records of all deals. And it’s irreversible. Please operate it carefully.
6.3.3 Clear stock information
Example 6-4 Clear stock information
Operations
Keys
Tare
0.000
『Sale Idle』
Enter Account
A1
【Account】
Enter clear report
A51
【5】
Clear manual
【3】
report
Input validate code 【9】
【9】
【5】
【8】
Display
Weight/ Change/
Count
U.Price
0.000
0.00
Total
Clear
Manly
Input
Code
Single/
Total
0.00
0
Remarks
〖Sale〗, 〖Sum〗 on.
〖Account〗 on.
Input validate code.
66
Confirm validate
code
Return to sale
mode
【Confirm】
【Sale】
----
-----
------
A53
Clear
Stock
0.000
0.000
0.00
N o t e 1 This operation would clear stock
-------
0.00
〖Sale〗, 〖Sum〗 on.
report. And it’s irreversible. Please operate it carefully.
6.3.4 Reposition SID information
Example 6-5 Clear manual report
Operations
『Sale Idle』
Enter Account
Enter clear report
Clear manual
report
Return to sale
mode
Keys
Tare
Display
Weight/ Change/
Count
U.Price
0.000
0.00
Total
Clear
Manly
【Account】
【5】
0.000
A1
A51
【4】
----
-----
------
A54
Clear
SID
0.000
0.000
0.00
【Sale】
Single/
Total
0.00
Remarks
〖Sale〗, 〖Sum〗 on.
〖Account〗 on.
-------
Wait a few seconds.
0.00
〖Sale〗, 〖Sum〗 on.
6.4 Stock Management
6.4.1 Stock Management
A6’s stock report and A44’s manual PLU report are choiceable( by Spec141) .
Stock report only support first 1000 saved PLU, if the real input PLU number >1000, the partial PLU can
notprocess stock management
6.4.2 Stcok Print
When print stock report, it will clue to input 2 digits, scale will in turn print the stock report those PLU
reports whose serial numbers is between the 2 input numbers as well as the 2 input numbers.
Example 6-6 Print stock Reports with the Numbers from 10 to 20
Operations
『Sale Idle』
Enter Account
Enter stock
management
Enter stock print
Input start number
Input end number
Keys
Display
Change/
U.Price
0.00
【Account】
0.000
A1
【6】
A61
Stock
Print
Input
2–1
0
Input
2–2
0
Start from PLU10.
…
…
…
End to PLU20.
10
11
Print
Print
【1】
【1】【0】
【Confirm】
【2】【0】
【Confirm】
Tare
…
Single/
Total
0.00
Remarks
Weight/
Count
0.000
Total
〖Sale〗, 〖Sum〗 on.
〖Account〗 on.
Print stock report of PLU10.
Print stock report of PLU11.
67
Return to sale
mode
【Sale】
0.000
0.000
…
Print
……
End of print.
0.00
0.00
〖Sale〗, 〖Sum〗 on.
N o t e 1 If some stock reports store no data, these buffers would be skiped off without printing
N o t e 2 If end number input is 0, system would only print the buffer appointed by start number.
N o t e 3 If end number input is not 0 and less than start number, no buffer would be printed.
6.4.3 Stock Audit
Example 6-7 Amend PLU10 stock to 100
Operations
『Sale Idle』
Enter Account
Enter stock
management
Enter stock print
Keys
Weight/
Tare
Count
0.000 0.000
Total
【Account】 A1
【6】
Amend to the
imput number
Return to sale
mode
Single/
Total
0.00
Stock
Print
Input
PLU-no
0
A61
pcs
0
10
0.000
0.000
0.00
0.00
【2】
Remarks
〖Sale〗, 〖Sum〗 on.
〖Account〗 on.
Pcs means default count unit.
When PLU is for weight, default
Present
Stock unit
PLUnumber
stockunit is scale’s unit kg
stock
【Amend】: amend stock to input
pcs
100
10
【1】
【0】
【0】 A61
number
【Confirm】: add input number to
stock
pcs
100
10
【Amend】 A61
【F-Prog】+【Confirm】: reduce
input number from stock
【1】【0】
Enter PLU number
【Confirm】
Enter stock
quantity 100
A61
Display
Change/
U.Price
0.00
【Sale】
〖Sale〗, 〖Sum〗 on.
N o t e 1 Use【F-Prog】+【PLU】 can amend the stock unit, make the weight PLU also with count stock.
Generally do not suggest user use this function. Detailed refer to Spec142
6.5 List Print
6.5.1 Sale Log
When user sale in sale interface, sale data will be recorded. This recorded data is source of all account
modes’ Stat. Date. Device has about 6000~10000 location according to different device’s configure. When the
log is being over capability, device will delete oldest log according to FIFO rule.
6.5.2 List Print
Example 6-8 Intraday List Print
Operations
『Sale Idle』
Keys
Tare
0.000
Display
Weight/ Change/
Count
U.Price
0.000
0.00
Single/
Total
0.00
Remarks
〖Sale〗, 〖Sum〗 on.
68
Enter Account
Enter stock
management
【Account】
A1
Total
【7】
A71
List
Enter stock print
【1】
Start print
【Confirm】
Return to sale
mode
【Sale】
A71
0.000
List
0.000
〖Account〗 on.
Print
Print
20
1
2
…
Print
Print
Print
0.00
0.00
Last window display the
location number used by
intraday
Print first unit’s record
Print second unit’s record
……
Print finished
〖Sale〗, 〖Sum〗 on
Example 6-9 Appointed Time Period List Print
Operations
『Sale Idle』
Enter Account
Enter stock
management
Keys
【Account】
Display
Weight/ Change/
Tare
Count
U.Price
0.000 0.000
0.00
A1
Total
Single/
Total
0.00
【7】
A71
List
Print
Enter stock print
【1】
A71
List
Print
Enter time period
【×】
Input
01 01
……
Input
01 01
……
Time-1
00 00
……
Time-2
23 59
……
List
Print
30
1
2
…
Print
Print
Print
0.00
0.00
Enter start time
2009
【…】
【Confirm】 …
Enter finish time
2009
【…】
【Confirm】 …
A71
Start print
【Confirm】
Return to sale mode
【Sale】
0.000
0.000
20
Remarks
〖Sale〗, 〖Sum〗 on.
〖Account〗 on.
Last window display the
location number used by
intraday
00 W-4
……
59 W-4
……
Last window display the
location number used by
appointed time period
Print first unit’s record
Print second unit’s record
……
End print
〖Sale〗, 〖Sum〗 on
69
7 Appendix
7.1 Reference Table For Errors and Its Instructions
Number
E0.00
E0.01
Alarm instructions
Alarms for measurements
Weight is not stable when the scale
start-up.
Methods to handle
Make sure there is no heavy goods on the tray and the tray
is stable. If scale still warns, the sensor may go wrong.
Make sure there is no heavy goods on the tray and the tray
is on the bracket, If scale still warns, the sensor may go
wrong.
E0.02
Exceed the allowed start-up zero range
E1.00
E1.01
Alarms for operations
Prog data is invalid.
Input passwords of 2 times to amend
password are different
Input valid data again.
Re-amend password, and make sure 2 times input are the
same.
E1.03
The selected print format do not exist
Set print format again
E1.10
Sale at 0 price is forbidden.
E1.11
Exceed the largest sale price.
E1.12
E1.13
Need to return to zero point
Exceed accumulative limit
There is data in buffer and cannot print
in single.
No cashing mode, cannot executethe
cashing operation.
Cashing mode with zero change
default is forbidden.
Payment is less than sale price.
System cannot execute accumulative
operations while locking PLU.
System cannot switch buffers into
buffer with accumulation while
locking PLU.
Not allow no weigh sale for weight
goods
Less than smallest sale weight
Larger than largest sale weight
Discounted U.Price has to be less than
discount lower limit.
Discounted U.Price has to be higher
than discount upper limit.
Discount is forbidden.
Manual weight entry is forbidden
Manual weight entry failed for weight
is not zero.
E1.02
E1.14
E1.15
E1.16
E1.17
E1.18
E1.19
E1.20
E1.21
E1.22
E1.23
E1.24
E1.25
E1.26
E1.27
The sale whose sell price is 0 is forbidden. Refer to
Spec070.
Total price or grand total price of sold goods exceeds the
largest sale price.
Return to weight zero before sale. Refer to Spec069.
The accumulative times are over buffer accumulat limit
Print the data in buffers first. Then print this sale or switch
to other buffers.
The scale is set to be no cashing mode. Refer to Spec060.
Execute cashing operation afer inputing payment amount.
Refer to Spec060.
Charge enough money which is larger than sale price.
Before accumulative operations, system needs to exit lock
PLU (or auto mode) first.
Operate in current buffern, or exit lock PLU (or auto
mode).
Refer to Spec071.
Weight needs to be larger than smallest sale weight.
Weight needs to be smaller than largest sale weight.
Discounted in allowed range, or amend the allowed range.
Refer to Spec110
Refer to Spec077
Take off goods, or press 【Zero】
70
Number
E1.28
E1.29
E1.30
E1.31
E1.32
Alarm instructions
T-Sale is forbidden
Sale of Weight PLU or count PLU is
forbidden.
Can not enter special sale mode
Working on forced auto printing after
zero-return. PLU Quiting is forbidden.
Transfer sale buffer is forbidden under
accumulate mode
Methods to handle
Refer to Spec076
Refer to Spec075
Selected PLU haveconflict with special sale mode, select
again
Finish printing of current PLU.
Press 【 Confirm 】 or 【 Cancell 】 exit the accumulate
mode,then go on transfer
E1.33
Transfer sale mode forbidden
Refer to Spec079
E1.34
The scanned barcode can not be parsed
Confirm the scanned PLU have been edited, interior
barcode format station right
E1.35
Tare renew function forbidden
Must turn over tare, then go for tare
E1.36
Salesman is not exist
Login with exist personel
E1.37
Salesman’s password can not be 0
Login with personel whose password is not 0
E1.38
Service charge is forbidden
Open the function at Spec307
Custom Product Alarm
E1.50~E1.59
Forbid F-Prog of PLU
Forbid F-Prog of PLU shortcut keys
Forbid F-Prog of Spec data parameters
Forbid Re-print
Menu quiting via pressing 【 Sale 】
【Prog】【Account】 is forbidden.
Refer to Spec080.
Refer to Spec081.
Refer to Spec082.
Refer to Spec065.
E2.06
A44 report forbidden
Refer to Spec141.
E2.07
A6 report forbidden
Refer to Spec141.
E2.09
Illegal reboot
Refer to Spec138.
E6.00
Alarms for peripheral
E1.5x
E2.01
E2.02
E2.03
E2.04
E2.05
E6.10
PTR: Print sensor calibrate wrong
E6.11
PTR: Gap paper is not taken away.
E6.12
E6.13
E6.14
PTR: Print mouth is not closed tight.
PTR: Printer is working.
PTR: Lack of plain paper
E6.15
PTR: Lack of gap paper
E6.16
PTR: The printer cannot find the gap
intervals.
E6.17
E6.18
PTR: The printer cannot find gap
alignment positions.
PTR: The printer is overheated and it
needs to cool down.
Quit the menu by press【Cancel】some times.
Do calibrate operation with Ethernet Printer
Take away the printed label paper. If the alarm still
warns, do calibrate operation with Ethernet Printer
Install the paper and close mouth.
Please wait for a few seconds and try again.
Reinstall plain paper or the paper type cannot match.
Reinstall label paper or the paper type cannot match. If
the alarm still warns, do calibrate operation with
Ethernet Printer
The paper type cannot match and change the type to plain
paper or reinstall gap label paper. If the alarm still
warns, do calibrate operation with Ethernet Printer
Label paper is used up or paper type cannot match with
set paper type. Please reinstall label paper.
Please wait for a few seconds and try again.
71
Number
E6.19
Alarm instructions
PTR: There is no response of the
printer.
E6.20
PTR: Print sensor calibrate wrong
E6.21
PTR: Communication Error
E7.00
Some keys are pressed when the scale
starts.
E7.10
Print sensor calibrate wrong
E7.11
Gap paper is not taken away.
E7.12
E7.13
E7.14
Print mouth is not closed tight.
Printer is working.
Lack of plain paper
E7.15
Lack of gap paper
E7.16
The scale cannot find the gap intervals.
E7.18
E7.19
The scale cannot find gap alignment
positions.
The printer is overheated and it needs
to cool down.
There is no response of the printer.
E7.20
The printer over time
E7.23
PDS calibration failed, ignore PDS
E7.30
E7.40
Alarm for full storage of deals records.
Time error
E7.50
E7.51
E7.52
Printer process do not follow general time order and finish
the working, unknown print error
Checkup the Ethernet cable
Alarms for hardwares
E7.01
E7.17
Methods to handle
The printer may not be connected or in the state that the
printer could not print.
Please confirm that no keys are pressed.
In this interface, the last window display pressed keys. 8-5
means the key in 8th column from the left and 5th row from
the top is pressed.
In this interface, the second window displays the
calibrated times.
Refer to chapter 1.5.5 Abnormity of Gap Paper Print to
calibrate again
Take away the printed label paper. If there is still alarm
this problem, do as the way in chapter 1.5.5 Abnormity
of Gap Paper Print to detect.
Install the paper and close mouth.
Please wait for a few seconds and try again.
Reinstall plain paper or the paper type cannot match.
Reinstall label paper or the paper type cannot match. If
there is still alarm this problem, do as the way in
chapter 1.5.5 Abnormity of Gap Paper Print to detect.
The paper type cannot match and change the type to plain
paper or reinstall gap label paper. If there is still alarm
this problem, do as the way in chapter 1.5.5 Abnormity
of Gap Paper Print to detect.
Label paper is used up or paper type cannot match with
set paper type. Please reinstall label paper.
Please wait for a few seconds and try again.
The printer may not be connected or in the state that the
printer could not print.
Printer process do not follow general time order and finish
the working, unknown print error
Try reclibrate, this failure will not effect general use
Enter Account interface. Calculate reports and then clear
the reports.
Time module error, if scale work for years, then it means
to change the battery on main board
Inside examine and repair code, if restart again andagain,
Harware error
but still exist this question, need return to factory for
repair
72
Number
Alarm instructions
Methods to handle
E7.53
E7.54
Font file check error
Download font from Software again.
E7.61
No MAC device
Please ask Service for MAC file.
Wire-Network module do not exist or
If no wire-network module in present scheme, please
working irregular
close the network module (Set Spec043=0) .
Wireless-Network module do not exist
If no wireless-network module in present scheme, please
or working irregular
choose wire-network module (Set Spec050=0) .
AD work irregular or loadcell irregular
Confirm loadcell install right
E7.62
E7.63
E7.70
If device is working with battery, please charge it first.
E7.81
DC power is too low
If user confirm that power is right, please set Spec235=1
to close the power detect module
If device is working with battery, it means battery is not
E7.82
match with the device.
DC power is too high
If user confirm that power is right, please set Spec235=1
to close the power detect module
E8.00
Alarms for communications
E8.11
USB flash disk port do not connect
with the scale.
E8.12
USB flash disk does not exist.
E8.13
The file in USB flash disk does not
exist.
Please confirm that the scale used owns U-Disk port. If it
owns, and this alarm cannot be cleared after several times’
reboot, please use the guarantee.
Please confirm that USB-Disk is correctly inserted with
two condition:
1. USB-Disk is formatted in FAT12/16/32. NTFS is not
supported by device.
2. USB-Disk is bootloaded as FDD. HDD/ZIP are not
supported by device.
Confirm that appointed files are inside of USB flash disk.
7.2 Definitions of Spec data parameters
Default values are different via different version. Value list blow is cfor reference only.
No.
0
1
2
3
4
5
Content
Range
Remarks
Default Permission
0 means not to print, 1~99 are to print in appoint
Bill 1: Item Print Format
0~99
1
0
Print formats.
0 means not to print, 1~99 are to print in appoint
Bill 1: Item Barcode Format 0~99
2
0
barcode formats.
0~
Bill 1: Item Barcode flag
20
0
9999999
Bill 1: Item Print Times
0~99
1
1
Bill 1: Item Print Reverse
0~1 0: No Reverse, 1: Print 180°Reversed
0
1
0 means not to print, 1~99 are to print in appoint
Bill 1: Sum Print Format
0~99
4
0
Print formats.
73
No.
Content
6
Bill 1: Sum Barcode Format
7
Bill 1: Sum Barcode Flag
8 Bill 1: Sum Item Print Times
9
Bill 1: Sum Print Reverse
10
Bill 2: Item Print Format
11 Bill 2: Item Barcode Format
12
Bill 2: Item Barcode Flag
13
Bill 2: Item Print Times
14 Bill 2: Item Print Reverse
15
Bill 2: Sum Print Format
16 Bill 2: Sum Barcode Format
17
Bill 2 Sum Barcode Flag
Range
Remarks
Default Permission
0 means not to print, 1~99 are to print in appoint
7
0
0~99
barcode formats.
0~
209999
0
9999999
9
0~99
1
1
0~1 0: No Reverse, 1: Print 180°Reversed
0
1
0~99
0
1
0~99
0
1
0~
0
1
9999999
0~99 For the second-class Print formats, ordinary
0
1
0~1 users won’t use them.
0
1
0~99 Please don’t amend them in normal conditions.
0
1
0~99
0
1
0~
0
1
9999999
0~99
0
1
0~1
0
1
0~99 Reduced % of paper speed
0
1
0~1 0: Plain Paper, 1: Gap Paper.
1
0
0~15 0 is lightest, 9 is darkest. The print lighter, the
5
0
0~15 damage to print header smaller.
5
0
18 Bill 2: Sum Item Print Times
19 Bill 2: Sum Print Reverse
20
Print Speed Slow Down
21
Paper Type
22
Gray Level of Gap Paper
23 Gray Level of Plain Paper
Plain Paper: Interval of Each
24
0~99
0
Print
Unit of setting number is mm.
25 Plain Paper: Cut-off Position 0~99
35
Plain Paper: Pre-feed
Unit of setting number is dot.
26
0~1999
16
Distance
Device is reverse feed if number > 1000
27
Wide of Report Printing
0~99 Unit of setting number is mm.
50
28
Font for Report Print
0~2
1
Continuously print appointed time will enter
29
Heat Protect
0~30
5
over-heat protect, Please don’t amend it.
Hardware properties. Please don’t amend them
180
30
Feed Sensor Position
0~255
without the guidance of professionals.
Narrow Bar Dot Number of
31
0~9
0
Barcode
0 for Default
Wide Bar Dot Number of
32
0~19
0
Barcode
Font of Barcode readable
33
0~2
0
character
Weighing's Anti-shake while
Hardware property, Please don’t amend them
3
34
0~19
without the guidance of professionals.
Printing
35
Auto New Line Mode
0~1 0: Forbidden; 1: Allowed
0
0: No frame;
1: Up and down frame;
36
ITF25 frame mode
0~2
1
2: Around frame
37
ITF25 frame width
0~31 Frame dots
8
0
0
0
0
1
1
1
1
1
1
1
1
1
1
74
No.
38
Content
ITF25 left and right blank
width
Range
Remarks
20
1
39 Gap Paper: Pre-feed Distance 0~1999
0
0
40
Device Number
0
0
41
RS232 Baud Rate
5
0
1
1
0
0
0
0
1
1
0
1
0
1
10
1
0
1
0
1
1
1
1
1
2
1
0
1
0
0
1
1
1
0
3
0
3
0
3
0
3
0
42 USB flash disk Auto Update
43
Ethernet Mode
44
Ethernet Auto Re-connect
45
Ethernet Auto Reboot if
Configure Changed
46
Latency Time of USB
Linking
47
USB Power Always ON
48
Ethernet Overtime Interval
49
Password Authorization
50 Ethernet Type (Need Reset)
51
Security Mode
52
Security Option
53
Domain Type
56
Print Function
57
59
RS232 POS Protocol
Sale Log Auto Save
60
Cashing Mode
61
Drawer In Sale Operation
62
Press【Drawer】in Sale
63
Press【Drawer】in Prog
64 Press【Drawer】in Account
0~31 Left and right blank dots
Default Permission
Unit of setting number is dot.
Device is reverse feed if number > 1000
0~ They are used to distinguish more than one
9999999 scale. And they can be printed.
0: 300, 1: 600, 2: 1200, 3: 2400, 4: 4800, 5:
0~9
9600, 6: 19200, 7: 38400, 8: 57600, 9: 115200.
0~1 0: No Update, 1: Auto Update
0~2 0: Disable; 1: Server Mode; 2: Client Mode
0: do not try connect again
0~65535 1~65535: Device will try to connect with PC
each appointed second
0: Disable, only reset change Ethernet config.
0~1
1: Enable, Ethernet config apply immediately.
0: Default wait 2s; 1~99: wait0.1s--9.9s.
Suggest clients keep the default set. If some
0~99
U-disk start slowly, you can try to change the
waiting time for longer
0~1 1: Enable
Single overtime seconds, over 5 times overtime,
0~31
Ethernet will disconnect
0: Device Operation Only
0~1
1: Communication Operation Allowed
0~1 0: Wire-Network; 1: Wireless-Network
0~2 0: No Security; 1: WEP; 2: WPA/WPA2
0~1 0: Open System; 1: Shared Key
0: FCC; 1: IC; 2: ETSI; 3: Spain; 4: France; 5:
0~6
JapanA; 6: JapanB
0:Print All as setting; 1:Print Bill 1;
0
2:Print Bill 2; 3:Print in PTR; 4:Print Forbidden
0~99 Refer to POS Protocol File
0~1 1: Sale Log Auto Save to USB-Disk in Account
0: No Cashing Mode,
1: Cashing Mode With Zero Change Default, No
Display For Zero Change,
0~3
2: Cashing Mode With Zero Change Default,
Always Display For Zero Change,
3: Cashing Mode Without Zero Change Default.
0~3 0: Not Open Drawer, 1: Open Drawer 1,
2: Open Drawer 2,
3: Open Drawer 1 and 2.
0~3 For general scale, only drawer 1 is valid, if user
have double drawer request, please contact us.
0~3 The added drawer password only limit the
【Drawer】operation, open the drawer while
0~3
printing is not limited
75
No.
Content
65
Reprint
66
Change Display Exit
67
Number Tare
68
PLU Tare
69 Zero-Return For Weight Sale
70
Range
Remarks
Default Permission
0: Reprint Forbidden
1: Print One Piece of Bill 1
0~4 2: Print One Piece of Bill 2
3
1
3: Print Each Piece of Bill 1 and 2
4: Print Bill 1 and 2 as Sale Operation
0: Push Any Key For Exit,
0~99
0
0
1~99: Auto Quit Exit Specified Second
0: Forbidden, 1: Input Value Tare,
0~2
0
0
2: Floating-point Value Tare.
0: Forbidden, No Resume Tare
1: Update If Current Tare Is Zero, No Resume Tare
2. Update if PLU Tare Is Not Zero, No Resume Tare
3. Always Update PLU Tare, No Resume Tare
0~7
1
0
4: Forbidden, Resume Tare
5: Update If Current Tare Is Zero, Resume Tare
6. Update if PLU Tare Is Not Zero, Resume Tare
7. Always Update PLU Tare, Resume Tare
0: Always need Zero-Return;
0~2 1: Zero-Return is need if Weight Changed;
1
0
2: No Zero-Return need, Print "*" before weight
0~1 0: Forbid; 1: Allow
0
1
0: Forbid; 1: Allowed, 1 pc only
0~2
0
0
2: Allowed, multi pcs allowed
74
Allowed Zero Purchase
No Weigh Sale for Weight
PLU
Clear Sale Buffer if Press
【Sale】
Think【T-Sale】As【U.Price
Convert】
Return of Goods
75
PLU forbidden
0~3
76
T-Sale PLU transfer
forbidden
0~3
77
Manual Weight Entry
0~3
78
【Auto mode】Get into
Special Sale Mode
0~4
71
72
73
79
80
81
82
83
Sale mode select
PLU Fast-Prog
ScPLU Fast-Prog
Spec Fast-Prog
Unit Price Fast-Prog
【[email protected]】 or 【@Price】
0~1
0~1
0~1
0~1
0~1
0~1
0~1
0~3
0: Not clear, 1: Clear.
0: Forbid; 1: Allow. Convert the input U.Price
unit from T-Sale Unit to Scale unit.
0: Forbid, 1: Allow.
0: No forbidden; 1: Weight PLU forbidden;
2: Count PLU forbidden; 3: All PLU forbidden.
0: No forbidden;
1: T-Sale Weight PLU forbidden;
2: T-Sale Count PLU forbidden;
3: All T-Sale PLU forbidden;
0: Disable, 1-3: Enable
0: Auto mode forbidden
1: Swith to batch print mode
2: Swith to prepack print mode
3: Swith to lock PLU mode
4: Swith to auto print mode
0: Forbid, 1: Allow.
0: Forbid, 1: Allow.
0: Forbid, 1: Allow.
0: Forbid, 1: Allow.
0: Forbid;
1: long press【[email protected]】 change PLU saved unit price
0
0
0
0
0
0
0
1
0
1
0
0
2
0
1
1
1
1
0
0
0
0
1
1
76
No.
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
Content
Range
Remarks
Default Permission
2: press【[email protected]】change PLU default unit price
3: press【[email protected]】change PLU default unit price, long
press to enter PLUsaved name edit menu
Wait several seconds after pressing the key to set
Stable Waiting: Set Zero
0~99 zero. If it’s stable in time, execute setting zero. If 20
0
(Each 10 for 1 Second)
not stable, error beep would sound.
Wait several seconds after pressing accumulative
Stable Waiting: Sale
0~99 or print in sale. If it’s stable in time, execute sale. 20
0
(Each 10 for 1 Second)
If not stable, error beep would sound.
0: Disable; 1: Use dummy PLU, when try to
transfer one do not exist PLU, device will use
this PLU number or other PLU item empty way
0
1
Dummy PLU
0~1
to transfer a dummy PLU. For example::
PLU156 do not exist, when transfer, you will get
a cargo name PLU-0156 ‘s PLU.
0: Disable
1: use dummy ScPLU, if one shout cut key have
been edited, then when it is transferred, scale
0
1
Dummy ScPLU
0~1
will transfer PLU according to its short cut
code. 【SC1】refer to PLU101, 【Shift】
【SC1】
refer to PLU201. Etc.
Step-skip of PLU Fast-Prog
0: Disable;
0~1
1
1
Equal to PLU Prog
1: Enable, P331 and P332 do same effect
Allow the scale to calculate report data in
Calculating Account
1
1
0~1
background. Suggest clients do not edit this item
Backgroud
Log record function
0~1 0: Enable, 1: Disable
0
1
0: use old version, PLU is 10~5999
Dummy PLU number
0~1 1: PLU is 1~9999999, temporary PLU number
1
1
decided by Spec093 and 096
Dummy number for
0~
999999
1
Temporary weight PLU 9999999
9
Dummy number for
0~
999999
1
Temporary count PLU
9999999
8
Refer to Spec092
Dummy number for Service
0~
999999
1
Charge PLU
9999999
7
Dummy number for Discount 0~
999999
1
& Rounding PLU
9999999
6
0: Forbidden; 1: Allow use number index
Index barcode from keyboard 0~2
1
1
2: Allow use number and character index
0: Not Record
Single count deal: discount
sum and rounding
0~5 1: Independent Record Discount, No Rounding
3
1
2:
Separate
Record
Discount,
No
Rounding
sum’smanage
3: Independent Record Discount and Rounding
Accumulate deal: discount
4: Independent Record Discount, Separate
sum and rounding
0~5
3
1
Record Rounding
sum’smanage
5: Separate Record Discount and Rounding
77
No.
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
Content
Range
Remarks
Default Permission
0, Common Rounding For Redundancy Digit
1, Common Rounding For Last Digit
Rounding Method for Single
2, Common Rounding For Last 2 Digits
0~1
0
0
Total Price
3, Banker's Rounding For Redundancy Digit
4, Banker's Rounding For Last Digit
5, Banker's Rounding For Last 2 Digits
6, Rounding Down For Redundancy Digit
7, Rounding Down For Last Digit
Rounding Method for Sum
8, Rounding Down For Last 2 Digits
0~11
0
0
Tota Pricel
9, Rounding to 0/5 For Last Digit
10, Rounding to 0/5 For Last 2 Digits
11, Rounding to 0/5 For Last 3 Digits
Print with accumulated data
0~1 0: Enable, 1: Disable
0
1
Equal Reparation of Tare,
0: No Reparation; 1: Tare=Gross-Net;
0~3
3
1
Net and Gross
2: Net=Gross-Tare; 3: Gross=Net+Tare
0: YYYY.MM.DD; 1: YY.MM.DD
Date Type
0~5 2: MM/DD/YY;
3: MM-DD-YY
0
1
4: DD/MM/YY;
5: DD-MM-YY
0: Using PLU setting
1: Shelf Printing based-on Spec106 if PLU Do
0
0
Shelf Day Print
0~2
not set Shelf Day
2: Shelf Printing based-on Spec106
Shelf life days after intraday.
Shelf Days
0~999
0
0
0 means only for intraday
Number of Sale Buffers
0~99 0: maximum allowed buffer
0
0
Number of Maximum
0~65535 0: maximum allowed accumulate
0
0
Accumulate
Divide Operation of U.Price 0~1 0: Normal Operation; 1: Divide Operation
0
Not open
0, All Allowed
1, Forbidden U.Price Discount
Manual Discount: Forbidden 0~3
0
1
2, Forbidden T.Price Discount
3, Forbidden All Discount
0: no lower limit, discount freely;
Manual Discount:
1~99: Take the percent of U.Price as the lower
Lower Limit
0~255
limit of the discount.
0
0
(Percent Number)
100~255: Don’t allow the price after manual
discount is lower than original U.Price.
0: no upper limit, discount freely;
Manual Discount:
1~100: Don’t allow the price after manual
Upper Limit
0~255
discount is higher than original U.Price.
0
0
(Percent Number)
101~255: Take the percent of U.Price as the
upper limit of the discount.
Percent Discount Arithmetic 0~1 0: Subtracter, 1: Addition
0
1
0: Manual input number
0
1
Auto Percent Discount Rate 0~99
1~99: Discount with this number
78
No.
Content
Range
115 Auto Discount: Price Lock
0~3
116
Global Tax Sort
0~3
117
Global tax rate(‱)
118
Amend mode in sale
119
Scanner checkout
120 Bar code match calculation
121
Deal method with code=0
122 Internal Barcode 1: Format
123
124
125
126
127
128
129
130
131
Internal Barcode 1: Flag
Number
Internal Barcode 2: Format
Internal Barcode 2: Flag
Number
Internal Barcode 3: Format
Internal Barcode 3: Flag
Number
Internal Barcode 4: Format
Internal Barcode 4: Flag
Number
Total Price Masked before
Printing
Auto Printing after
Zero-return
Remarks
0: No Auto Discount
1: Price Lock if Auto Discount Is Effective
2: Price Lock If Auto Discount Is Setting
3: Price Lock for All PLU
Price Discount disable when price is tracking.
0: No global tax rate
1: Default is exclude Tax with Excluded Rate
2: Default is include Tax with Excluded Rate
3: Defaultx with included Rate
0~9999 0.01% tax rate, for 17%, need input 1700
0: Manual;
0~2 1: Record and clear
2: Not record and clear
0: Not checkout, ignore reduncdance information
0~2 1: Checkout, ignore reduncdance information
2: Checkout, not ignore reduncdance information
0: Do nothing
1: Deal with External Barcode (Index mode)
0~3
2: Deal with Internal Barcode (Code mode)
3: Deal with all mode
0: Search user PLU
0~2 1: Deal with By-Weight T-Sale PLU
2: Deal with By-Count T-Sale PLU
Group 1 interior bar code format, if Spec122=0,
0~99 device auto use Spec1 and Spec2 as Group 1
interior bar code format
0~
9999999
0~99 Group 2 interior bar code format
0~
9999999
0~99 Group 3 interior bar code format
0~
9999999
0~99 Group 4 interior bar code format
0~
9999999
0: Not enable
0~1
1: Enable. Total Price only displays after printing
0: Not enable.
1: Auto record after Zero-return. Can press
【Cancel】to exit, do not record after exit
0~4 2: Forced auto record after Zero-return. Force
operator to print the trade or take record.
3: Auto Printing after Zero-return. Can press
【Cancel】to exit, do not record after exit
Default Permission
1
1
1
0
1
0
0
1
2
1
3
1
1
1
0
0
0
0
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
79
No.
132
133
134
Content
Accu Mode: Transferring
PLU by Key Input
Accu Mode: Transferring
PLU by External Barcode
Accu Mode: Transferring
PLU by Internal Barcode
Range
Remarks
Default Permission
4: Forced Auto Printing after Zero-return. Force
operator to print the trade or take record.
0~1
0~1
0: Disable
1: Enable
0~1
0: No salesman mode, log in with salesman 0.
1: Login V1~V4 with Salesman 1~4, No
password
2: Password Enable, V1~V4 by Same Salesman
135
Salesman mode
0~5 3: Password Enable, V1~V4 by Different Salesman
4: Password Enable, V1~V4 by Same Salesman,
Pass=0 Salesman Cannot login
5: Password Enable, V1~V4 by Different
Salesman, Pass=0 Salesman Cannot login
0: Disable
136
Waiter Mode
0~2 1: Enable, Forbidden dummy personnel
2: Enable, Allowed dummy personnel
0: Always clear; 1: Memory last one
137
Waiter Memory Mode
0~2
2: Memory in buffer
138 Right of Default Salesman 0~65535 Please use software
139
EAN/UCC CRC
0~1 0: Standard, 1: Non-standard
0: Disable; 1: Half day clear(12:00 and 0:00)
2: Each day clear; 3: Each Saturday clear
140
SID auto clear
0~6
4: Each Monday clear; 5:Each month clear
6: Each quarter clear
0: Disable(A44 Report Enable)
141
Stock report
0~1
1: Enable(A44 Report Disable)
0: Only PLU's Unit Allowed
1: Default By-Weight Unit and By-Count Unit
142 Stock change unit mode
0~2
Allowed
2: All System Unit Allowed
0: Print as number
143
FID/SID Print Mode
0~9
1~9: Print in specified length with ’#’
144 Each Item has Indentify FID 0~1 0: Forbidden; 1: Enable.
+1: Print Picture 1; +2: Print global text 0
145 Print extra info in report 0~65535
+4: Print global text 1; +8……
150
0~255
When Spec153 is 0, device will connect to
151
0~255
Scale’s Ethernet IP
network by DHCP. Otherwise use appointed IP
152
0~255
to connect the network
153
0~255
154
0~255
When the network under clients
PC’s Ethernet IP
155
0~255
state( Spec043=2) , appoint PC’s IP.
156
0~255
0
1
1
1
1
1
1
0
0
1
0
1
0
0
1
1
2
1
1
1
1
1
6
1
0
1
0
1
192
168
0
0
0
0
0
0
0
0
0
0
0
0
80
No.
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
180
181
182
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
Content
Range
Remarks
0~255
0~255
0~255
Scale’s Ethernet gateway
Getway: not use DHCP to connect to network
0~255
0~255
0~255
0~255
Scale’s Ethernet mask
Getway: not use DHCP to connect to network
0~255
0~255
Scale’s server port
0~65535
Do not change such setting unless there are
Scale’s clients port
0~65535
expert! Irrelevant change will make the network
Scale’s UDP local port
0~65535
do not work
Scale’s UDP remote port 0~65535
0~255
0~255
Primary DNS
Primary DNS for dns analysis
0~255
0~255
Display and Printing of
0: Dot’.’;
0~1
Radix Point
1: Comma’,’
0: Not printing;
1: Dot’.’;
Printing of Kilocharacter
0~3
2: Comma’,’
3: Quotation Mark’ '’
Display of Kilocharacter
0~1 0: Not display; 1: Display based on Spec181
Unit Printing of Weight
0~1 0: No printing; 1: Printing
Unit Priting of Unit Price
0~1 0: No printing; 1: Printing
Unit Priting of Money
0~1 0: No printing; 1: Printing
Unit Price Length
0~6 0: Use System Length; 1~6: Specified Length
Total Price Length
0~7 0: Use System Length; 1~7: Specified Length
5-Windows Scale:
0: Auto Fix
PLU Name Display
1: Font 1 Display
0~3
2: Font 0 Display
5-Windows Scale:
3: 2-Line Mode
AD-Message display
5-Windows Scale:
0: Display Time;
1~3: Reserved
0~23
Display in Idle Mode
4~23: Global String data of Scale (0~19)
5-Windows Scale:
0: Display Accumulation Information
Display in accumulated mode
1: Display AD-Message
5-Windows Scale:
0~7
PLU Info Text Source 1
0: PLU Name
1~7: Text1~7
5-Windows Scale:
0~7
PLU Info Text Source 2
Decimal Point of Count In
0~5 Similar as spec208
Barcode Print
Fast Track of Weighing
0~4 0: Default level, 1~4: the bigger, the faster
Delay of Zero Judgement
0~19
100ms per one
Delay of Stable Judgement
0~19
Decimal Point: Tare
0~3 In default state, decimal digits of tare.
Default Permission
0
0
192
0
168
0
0
0
1
0
255
0
255
0
255
0
0
0
33581
1
33582
1
33583
1
33584
1
8
0
8
0
8
0
8
0
0
2
0
2
0
0
0
0
0
0
2
1
1
1
1
1
3
1
3
1
3
1
3
1
0
1
0
1
3
1
0
4
0
3
1
1
1
1
81
No.
Content
201
Decimal Point: Weight
202
Decimal Point: U.Price
203
Decimal Point: T.Price
204 Decimal Point Fix: Tare
205 Decimal Point Fix: Weight
206 Decimal Point Fix: U.Price
207 Decimal Point Fix: T.Price
208
Decimal Point of Weight In
Barcode Print
209
Decimal Point of Money In
Barcode Print
210
T-Sale Unit
211
System U.Price Unit
212
System Weight Unit
213
Weight Precision
214
Default measure sort
215 Maxium Overflow Degree
216 Maxium Underflow Degree
217
Minium Sale Degree
218
Zero Tracking Degree
Range
0~3
0~5
0~5
0~1
0~1
Remarks
Default Permission
In default state, decimal digits of weight.
3
1
In default state, decimal digits of U.Price.
2
1
In default state, decimal digits of T.Price.
2
1
Fix display decimal point according to Spec200
0
1
Fix display decimal point according to Spec201
0
1
Fix display decimal point according to Spec202
0~3 0: No Fix; 1: Fix for Discount;
3
1
2: Fix for PLU Call Out; 3: Always Fix.
Fix display decimal point according to Spec203.
0~2 0: No Fix; 1: Fix based on Spec100;
1
1
2: Common rounding before fix based on Spec100
For number 1.533, if number here is 2, print 153
3
1
0~5
when print barcode. If number here is 3, print
1533. The rest may be deduced by analogy.
0~5 Generally suggest Spec208=Spec201,
2
1
Spec209=Spec203
0, 1, 2: System Default;
0~8 3: kg Unit;
0
1
4: g Unit;
5: ton Unit;
6: lb Unit;
7: 500g Unit;
8: 100g Unit;
0~8 There are some relations among 3 units.
0
1
Relations are a little different in different
0~8 editions because the measuring systems are
3
1
different in different countries.
0: 10g, 3000
1: 5g/10g, 6000/3000
TM-30A
30kg
2: 2g/5g, 15000/6000
3: 1g/2g, 30000/15000
0: 5g, 3000
1: 2g/5g, 7500/3000
TM-15A
15kg
2: 1g/2g, 15000/7500
3: 0.5g/1g, 30000/15000
0~3
1
1
0: 2g, 3000
1: 1g/2g, 6000/3000
TM-6A
6kg
2: 0.5g/1g, 12000/6000
3: 0.2g/0.5g, 30000/12000
Only precisions of unit kg are listed here. Other
units may be a little different. When users use
precisions of 2 or 3, weight print would display
“*” which means it’s only for industrial use.
0: Non-input PLU is by-weight as default
0~1
0
1
1: Non-input PLU is by-count as default
0~99
9
1
0~99 Degree number, there is no limit if number is 0.
9
1
0~99
4
1
0~99999 Unit is: e/10
0
2
82
No.
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
244
245
246
247
Content
Range
Remarks
Default Permission
Tare Range
0~99
0
2
Range of the Initial Zero
0~99
9
2
Range of the Single Manual
0~99 Percentage number. No limit if number is 0.
2
2
Zero
Range of the Accumulative
0~99
2
2
Manual Zero
Zero Flag Range
0~99
4
2
Zero Tracking Range
0~99 Inter-code
5
2
Stable Flag Range
0~99
6
2
Tare can Overrun Capacity 1 0~1 0: Forbidden; 1: Allowed
0
1
Tare Update
0~1 0: Forbidden; 1: Allowed
1
1
Price Convert betweent
0: Allowed; 1: Only Default Weight Allowed
0~2
0
1
Different Weight Unit
2: Forbidden
0: Forbidden; 1: Long Press to Switch;
Weight Switch
0~2
1
1
2: Single Press to Switch
AD Anti-shake while printing 0~7 Hardware parameter
2
1
Zero forbidden in PLU Mode 0~1 0: Zero is allowed; 1: Zero is forbidden
0
1
0: Always based on low capability
Floating-point of weight
0~2 1: Based on current capability, low is priority
0
1
2: Based on current capability, high is priority
Zero back is necessary for
0: No need
0~1
0
1
fast weight unit switch
1: Need
Degrees of Zero back
0~31 Judgement Value of Zero back
0
1
Power Detect Module
0~1 0: Enable; 1: Disable
0
1
Print in Battery Mode
0~1 0: Print; 1: Not print
0
1
Interval of Key Scanner
0~4 Hardware parameter
1
1
Anti-shake of Key Scanner
0~4 Hardware parameter
1
1
Time for open drawer
0~9999 0~9999ms. Default 100ms
100
1
Ignore PBS Sensor
0~1 Use to oblige elimate error E7.12
0
1
Ignore PDS Sensor
0~1 Use to oblige elimate error E7.11
0
1
Ignore PPS Sensor
0~1 Use to oblige elimate error E7.14
0
1
Password is memoried and no need to input
again once it is input. Memory is cleared on
restart or parameter amend.
Password hold function
0~3 0: Not hold any password
0
1
1: Only hold drawer password
2: Hold all password except admin password
3: Hold all password
249
PLU Text Mode:
PLU Text Length ≈
Total Length-150
0~4
0: Default
1: 256 Bytes Mode; 2: 512 Bytes Mode
3: 1024 Bytes Mode; 4: 2048 Bytes Mode
0
1
250
No-Accumulation Mode
【Accu】is Doing Same
Operation as【Print】
0~1
0: Disable this mode
1: Enable this mode
0
1
83
No.
Content
Range
Remarks
Default Permission
0: Disable discount menu
251 Discount Menu of Unit Price 0~4 1: Enable, default mode is based on【Key】
0
1
2: Enable, default mode is PERCENT mode
252 Discount Menu of Total Price 0~4 3: Enable, default mode is MINUS mode
0
1
4: Enable, default mode is FIX mode
Call PLU by “Item-Code”
0: Based on PLU number
0
1
253
0~1
1: Based on PLU Item-Code
when Press 【PLU】
0: Disable;
1: Enable in idle mode
254
0~3
0
1
Auto【PLU】Function
2: Enable in PLU mode; 3: Enable in all mode
0: Disable
255 Digit number for auto【PLU】 0~7
0
1
1~7:Auto【PLU】after digtals number inputted
256
Pre-Print Function
0~1 0: Disable; 1: Enable
1
1
Need Admin Password In
0: Normal;
+1: Sale;
+2: Prog
0
1
260
0~31
Certain Mode
+4: Account; +8:【Drawer】; +16: Unit Price
0: Normal
By-Weight PLU Forbidden in
261
0
1
+1: Batch Print,
Certain Mode
0~15 +2:PrePack,
By-Count PLU Forbidden in
+4:Lock PLU,
262
0
1
Certain Mode
+8:Auto Print
Call PLU automatically in 0~99999 In idle status, device will call specified PLU
0
1
263
Idle status
99 automatically
AUTO MODE transaction
+1: Batch Print; +2: Prepack;
264
0~15
0
1
record as “Auto”, not “Sale”
+4: Lock PLU; +8: Auto Print
265 Date Print Mode:Month
0~1 0: Digits; 1: Two Characters
0
1
266
Date Display Mode
0~1 0: Default; 1: Using Spec104 and 265
0
1
267 Fast Switch with Weight Unit 0~1 0: Default; 1: Forbidden Non-Standard
0
1
268
Auto Tare Lock
0~1 0: Default; 1: Auto Lock
1
1
269
Print Forbidden
0~1 1: Forbidden Print Model
0
1
0: Disable;
1: Enable if No PLU;
270
Weight Display Hidden
0~2
0
1
2: Enable if No Unit Price
271
Auto Upgrade
0~1 0: Disable; 1: Enable
0
1
0: Mid-Track;
272
Filter Mode
0~2 1: Multi-Average;
0
1
2: Suited-Average
0~99999
999999
274 Maximum PLU Number
0 Means no limit
1
99
4
275
Uniscribe Script
0~2 0: Disable, 1: RTL in LTR, 2: LTR in RTL
0
1
0: Normal; 1: Batch Print; 2: PrePack; 3: Lock
0
1
277
Default Working Mode
0~2
PLU; 4: Auto Print.
278 Hangup Bill Print Format
0~99 0: default; 1~99: specified print format
0
1
0: Forbidden;
1: Only hangup bill can be load once;
279
Hangup and Loadback
0~3
0
1
2: Only hangup bill can be load, no times limit;
3: All bill can be load
280
Salesman authorization
0~1 0: Forbidden; 1: Enable
0
1
282 Payment Operation Forbidden 0~63 0: all enable, 1~63: Please use software
0
1
84
No.
Content
283 Record of Unconfirmed Data
287
288
289
290
291
292
293
non-VIP Discount Off
VIP Default Discount Off
Other Transaction Print
Format
Log Text 1
Log Text 2
Log Text 3
Log Text 4
Range
Remarks
Default Permission
0: Disable; 1: Record Priced Operation;
0~2
1
1
2: Record Priced/Weighted Operation
0~99 Percent-Off
0
1
0~99 0:Same as Spec287, 1~99: Specified Percent Off
0
1
0~99 0: Default; 1~99: Specified Pritn Format
0
1
0~14
0~14
0~14
0~14
0
0
0
0
1
1
1
1
0
1
0
0
1
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
1
6
7
1
1
1
1
1
0
0
(Need Special Firmware Version)
0: Blank; 1: PLU Name; 2~8: PLU Text1-7;
9: Item Code; 10: Index Barcode;
11~14: Custom Info 1~4
0: Auto Clear Custom Info1~4;
294
Keep Custom Info
0~15 +1:Keep Custom Info 1; +2:Keep Custom Info 2
+4:Keep Custom Info 3; +8:Keep Custom Info 4
297 Second Currency Exchange
xxx Please use software
298 Second Currency Decimal Dot 0~5 Decimal dot position
0: Default; 1: desk scale;
299 Default stable arithmetic
0~3
2: platform scale; 3 hanging scale
0: Forbidden
300
Item Service Fee
0~2 1: Allowed, not collect total percent again
1: Allow, collect total percent again
Item Service Fee: Default
0: Unit price mode; 1: Total price mode;
301
0~2
Method
2: Percent mode
0: Manual call, manual input price
1: Manual call, manual input percent
Total Service Fee: Input
2: Manual call, take auto price
302
0~5
Method
3: Manual call, take auto percent
4: Auto call, take auto price
5: Auto call, take auto percent
Under price mode, auto account according to
Total Service Fee: Auto
0~
303
price decimal point
collect based number
9999999
Under pecent mode: unit is ‱
Service Fee: Percent
0: Based on price before tax
304
0~1
Collection based Number
1: Based on price after tax
0: No global tax rate
1: Default is exclude Tax with Excluded Rate
305
Tax Sort of Service Fee
0~3
2: Default is include Tax with Excluded Rate
3: Defaultx with included Rate
306 Tax Rate of Service Fee (‱)0~9999 0.01% tax rate, for 17%, need input 1700
307
Service Fee Permission
0~1 0: Forbidden, 1: Allowed
308
Service Fee Re-Input
0~1 0: Forbidden, 1: Allowed
340 Dot matrix LCD’s contrast 0~7
Do not change these settings.
341 Dot matrix LCD’s brightness 0~31
(PTR, parameters setting for network printer)
0 means print according to bill 1 format (once
350
PTR: Item print format
0~99 using bill 1 format, the barcode format and
signals are all according to bill 1)
85
No.
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
400
401
Content
PTR: Item barcode format
Range
Remarks
0~99
0~
PTR: Item barcode flag
9999999
PTR: Item print Times
0~99
PTR: Item print Reverse
0~1 0: No Reverse, 1: Print 180°Reversed
0 means print according to bill 1 format (once
PTR: Sum Print Format
0~99 using bill 1 format, the barcode format and
signals are all according to bill 1)
PTR: Sum Barcode Format 0~99
0~
PTR: Sum Barcode Flag
9999999
PTR: Sum Item Print Times 0~99
PTR: Sum Item Print Rol
0~1 0: No Reverse, 1: Print 180°Reversed
0: Disable
1: Enable, wait till printing finished
PTR: network print function 0~3
2: Enable, wait till printing started
3: Enable, wait till data sending finished
0: No operation
1: Online/offline clew
2: Online/offline clew, alarm when there is no
PTR: printer status clew
0~3
rating printing
3: Online/offline clew, error when there is no
rating printing
PTR: rating number for
0~20 Alarm or error if less than rating number
printer
PTR: check interval
0~65535 Unit: second, default for 10s
0~255
0~255
PTR’s IP: No.1
0~255
0~255
0~255
0~255
PTR’s IP: No.2
0~255
0~255
0~255
0~255
PTR’s IP: No.3
0~255
0~255
PTR: Server Socket
0~65535
Do not change such setting unless there are
PTR: Client Socket
0~65535
expert! Irrelevant change will make the network
PTR: UDP Local Socket 0~65535
printer do not work
PTR: UDP Remote Socket 0~65535
PTR: Print speed decrease
0~99 Reduced % of paper feed speed
PTR: Paper Type
0~1 0: Plain Paper, 1: Gap Paper.
Default Permission
0
0
0
0
1
0
1
1
0
0
0
0
0
0
1
0
1
1
1
1
1
1
0
1
0
0
0
0
0
0
0
0
0
0
0
0
0
33591
33592
33593
33594
0
0
1
0
0
0
0
0
0
0
0
0
0
0
0
1
1
1
1
1
0
86
No.
Content
Range
Remarks
Default Permission
PTR: Gray Level of Gap
0
402
0~9 0 is lightest, 9 is darkest. The print color lighter, 7
Paper
the damage to print header smaller. Suggest
PTR: Gray Level of Plain
403
0~9 users use lighter grey level.
7
0
Paper
PTR: Plain Paper: Interval of
404
0~99
0
0
Each Print
Set the unit of number is mm.
0 means use default set
PTR: Plain Paper: Cut-off
405
0~99
0
0
Position
Unit of setting number is dot.
PTR: Plain Paper: Pre-feed
0
0
406
0~1999
Device is reverse feed if number > 1000
Distance
407
PTR: Paper width
0~99
0
0
408
PTR: Default font
0~2
1
1
Continuously print appointed time will enter
PTR: Printer over-heat
1
409
0~30 over-heat protect, Please don’t amend them 0
protect
without the guidance of professionals.
Hardware properties. Please don’t amend them
410 PTR: Feed Sensor Position 0~255
180
1
without the guidance of professionals.
PTR: Point numbers for
411
narrow bar in barcode
0~9
0
1
0 for default set, Please don’t amend them
printing
without the guidance of professionals.
PTR: Point numbers for wide
412
0~19
0
1
bar in barcode printing
PTR: Readable character
413
0~2
0
1
fonts in barcode printing
415 PTR: Auto new line mode
0~1 0: One line mode; 1: Auto new line mode
0
1
PTR: ITF25 barcode frame
0: No frame; 1: Up and Down frame;
1
1
416
0~2
2: Around frame
mode
PTR: ITF25 barcode frame
417
0~31 Frame dots
8
1
width
PTR: ITF25 barcode left and
418
0~31 Left and right blank dots
20
1
right blank width
Unit of setting number is dot.
PTR: Gap Paper: Pre-feed
0
0
419
0~1999
Device is reverse feed if number > 1000
Distance
420 PTR: Ignore PBS Sensor
0~1 Use to force remove error E6.12
0
1
421 PTR: Ignore PDS Sensor
0~1 Use to force remove error E6.11
0
1
422 PTR: Ignore PPS Sensor
0~1 Use to force remove error E6.14
0
1
450 PDF417: Checksum Level
0~9 0~8: Fix level; 9: System default level
9
1
451 PDF417: Columns Number 0~30 0: Auto sizing, 1~30: Fix number
0
1
452 PDF417: Rows Number
0~90 0~2: Auto sizing, 3~90: Fix number
0
1
453
PDF417: Bar Width
0~6 0: Default 3
0
1
454
PDF417: Bar Height
0~18 0: Default 6
0
1
455
QR: Check Level
0~3
1
1
456
QR: Version
0~31 QR Minimum Version
0
1
457
QR: Bar Size
0~6 0: Default=3
0
1
480 Custom Version Reserved
~499
Spec
87
7.3 Definitions of String data paremeters
Number
0
1
2
3
4
5
6
7
8
9
10
11
12
13
Hint
Text content
Default Print
ShopN
Store Name
Header center
ScaleN
Device Name
Not use
MnyPre Prefix of Money Unit
MnySuf Suffix of Money Unit
Strg-1
Bill text 1
Header center
Strg-2
Bill text 2
Header left
Strg-3
Bill text 3
Header center
Strg-4
Bill text 4
Header left
Strg-5
Bill text 5
End center
Strg-6
Bill text 6
End left
Strg-7
Bill text 7
End center
Strg-8
Bill text 8
End left
SpSt-1
Special text 1
Reserved
SpSt-2
Special text 2
Reserved
Number
14
15
16
17
18
19
20
21
22
23
24
25
26
27
Hint
Ind-MK
W-SSID
W-PASS
SpSt-6
SpSt-7
Domain
Cstr-1
Cstr-2
Cstr-3
Cstr-4
Cstr-5
Cstr-6
Cstr-7
Cstr-8
Text content
Default Print
Industry Mark
Industry Mark
WiFiSSID
Wireless SSID
WiFi Password Wireless Password
Special text 6
Reserved
Special text 7
Reserved
Special text 8
Reserved
Custom Text 1
Custom Text 2
Custom Text 3
Custom Text 4
Custom Text 5
Custom Text 6
Custom Text 7
Custom Text 8
7.4 Definitions of Shortcut Function Key
1
Number:0
2
Number:1
3
Number:2
4
Number:3
5
Number:4
6
Number:5
7
Number:6
8
Number:7
9
Number:8
10
Number:9
11
Number:00
12
Clear
13
Cancel
14
Accu/Confirm
15
Cash/Print
16
PLU
17
F-Prog
18
V1
19
V2
20
V3
21
V4
22
Amend
23
×
24
Feed
25
SetZero
26
SetTare
27
Sale
28
Prog
29
Account
30
Time
31
-%
32
-Num
33
@Price
34
TSale
35
CashBox
38
Manual Weight
39
Paper Type
40
Pre/Re Print
41
Shift
44
Print2
45
CCard
46
MoveDot
47
U.W. Sample
48
Weight Accu
49
Division
50
UnitChange
51
Lock Tare
52
Auto Mode
53
Normal Mode
54
Batch Mode
55
PrePack Mode
56 LockPLU Mode 57 AutoPrint Mode 58
Service Fee
59
←V→
60
Mode
62
On/Off
63
66
VIP
Custom Info 1
77
67 Other Transactions 76
PayOther-0
64
Custom Info 2 78
PayOther-1
65
PayOther-2
Custom Info 3
79
Custom Info 4
88
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project