TUTA S30 GSM Power Socket User Manual
Below you will find brief information for GSM Power Socket S30. This device is a remotely controlled power socket that uses a GSM SIM card to allow you to turn it on or off from your mobile phone. You can control the socket output manually by pressing a button on the device or by sending SMS commands. You can also set a schedule to automatically turn the socket on or off at specific times, and you can even control the socket based on the surrounding temperature. This device is ideal for controlling electrical appliances in your home or office, such as lights, fans, or heaters.
advertisement
Assistant Bot
Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.
TUTA S30
GSM Power Socket
User Manual
Manual version 2.3
TUTA S30 GSM POWER SOCKET USER MANUAL
TUTA S30 GSM Power Socket
Thank you for purchasing the TUTA S30.
The TUTA S30 GSM power socket is a remote controlled socket consisting of a
GSM module. The power supply output of the socket can be turned on or off remotely by the SMS (Short Message System) command or local controlled by pressing button. It is an intelligent power supply socket controlled by users’ mobile phone at anytime and anywhere.
TUTA S30 is suitable for controlling electrical appliances which power consumption less than 3000W in household or office. It is universal for all kinds of indoor power supply sockets.
With extended-connected temperature sensor, TUTA S30 can switch on or off the socket output according to the environment temperature. It’s available for power control of the heating or refrigeration plant, to keep the environmental temperature within presetting range or at a fixed temperature value.
Furthermore, a SMS notification will be sent to master’s mobile phone if TUTA
S30 detects the rapid-changing or the reaching of pre-set alert value of surroundings temperature.
TUTA S30 is mainly applied for house and office usage. It is not suited for industry application, especially in humidity or dust condition.
All services and functions need to be supported by the GSM network and a SIM card.
This brochure suits for TUTA S30 model.
Details of the functioning and advanced operation of this socket are described in this instruction manual.
2
TUTA S30 GSM POWER SOCKET USER MANUAL
CONTENTS
3
TUTA S30 GSM POWER SOCKET USER MANUAL
4
TUTA S30 GSM POWER SOCKET USER MANUAL
1. Purchase a GSM SIM card (mobile phone card) from GSM network service and install it in the socket. This SIM card number is referred as
TUTA S30 number on this brochure.
2. The user needs to activate the Caller ID Presentation function of SIM card, and deactivate PIN code of the SIM. Contact with GSM network service for support.
3. Change the original password at the beginning use. Be sure to keep the password and SIM card number secret. Do not disclose this information to anyone other than the authorized users in order to ensure your safety.
For your safety
λ
This socket was designed for home or office use. Do not use it on the electrical appliance which is for industry or business operation, for example,
λ iatrical appliances, large heaters and refrigerates.
Before using this socket, make sure that the mobile phones can be used well
λ in the area, otherwise, do not put this socket into operation.
The power consumption of the appliances connected with the socket cannot
λ exceed 3000W and the current cannot exceed 15A.
The electrical appliance which power consumption is higher than 1500W must be grounded.
λ
Do not make two plugs of socket short circuit.
λ
Do not touch the socket jack by any metal objects or hand.
λ
This socket was designed for indoor use. Don’t use it in wet, chemically aggressive or dusty environment.
λ
Do not open the case unless maintenance needed.
λ
Do not keep shaking or fall down this socket, otherwise it can be damaged.
λ
This socket is a wireless signal transmission socket. Keep it away from electronic equipment likely to interfere with the wireless signals, in order to
λ
λ avoid signals interference.
λ
Switch off this socket and mobile phone when entering areas marked
"Explosive", "Might explode", "Closed wireless transceiver sockets" etc.
Do not cast this socket in a fire, as this may cause explosion.
This socket should only be operated from power approved by the socket
5
TUTA S30 GSM POWER SOCKET USER MANUAL manufacturer. The use of any other types of power may damage the socket.
λ
Keep the socket and its accessories out of the children reach.
Exception clause
1. We operate on a policy of continuous development. We reserve the right to make changes and improvements to any of the sockets described in this document without prior notice.
2. For the latest socket information, please visit: http://www.i-tuta.com. We don’t guarantee for the document veracity, reliability or any content except regulate in proper laws. Including no guarantee for socket suitable market or suitable area promise.
3. We hold no responsibility for the illegal use of this socket.
4. We hold no responsibility for any loss of income or any special, incidental, consequential or indirect damages howsoever caused.
5. The contents of this document are provided “as is”. Except as required by applicable law, no warranties of any kind, either expressed or implied, including, but not limited to the accuracy, reliability or contents of this document. We reserve the right to revise this document or withdraw it at any time without prior notice.
Chapter 1 Features and accessories
1.1 Main function
λ
This socket uses a GSM SIM card.
λ
Remotely operate by SMS command: The socket be controlled and set by sending SMS commands.
λ
λ
Input: 110V-250V/50Hz.
Output: Max.15A for long-duration operation.
λ Relay: 30A/250V relay with two working status power on/off for output outlet.
λ M button: To manual control output power on/off.
λ
Delayed control socket output.
λ Auto operates by preset schedule: Fixing-time control output power on/off.
λ
External temperature sensor supported: Send environmental temperature
SMS to mobile phone.
6
TUTA S30 GSM POWER SOCKET USER MANUAL
λ Auto operates by temperature: Available for power control of the heating or refrigeration plant, to keep the environmental temperature within presetting range or at fixed temperature value.
SMS alarm when temperature rapid-changing or reaching the pre-set
λ
value: When it detects the rapid-changing or the reach of pre-set alert value of surroundings temperature, it can auto-send the SMS alarm message to master’s mobile phone.
λ
Support 5 mobile phone users.
λ
Auto time-synchronization.
λ
SMS notification upon external power source changing.
1.2 Package contents
1. GSM power socket 1 unit
2. Temperature sensor 1 unit
3. User manual 1 unit
1.3 Sockets instructions
Figure 1: TUTA S30 instructions
1. Data port 5. Indicator light (Power, GSM, Output)
2. Temperature sensor port 6. Socket plugs
3. M button 7. Power switch
7
TUTA S30 GSM POWER SOCKET USER MANUAL
4. Electrical outlet 8. SIM card holder
Figure 2: Temperature sensor Instruction
1. Standard 3.5mm interface (put into 2 of Figure1)
2. Temperature sensor
1.4 Light indicator and “Beep” warning tone
Indicator
Power (Green) light
Action
Turning off No power supply input
Constant light Has power supply input
Status
GSM (Blue) light
Output (Red) light
“Beep” warning tone
(Default turning off)
Turning off Not installed SIM card, or the power switch of socket is
Flash
“OFF”.
Be busy or searching GSM network.
Constant light Successfully load to GSM network.
Constant light The socket outlet has power supply.
Turning off The socket outlet cuts power supply.
One time The socket outlet changes power supply status.
Several times TUTA S30 lost external power supply.
Long Beep TUTA S30 is successfully register GSM network, or it is successfully reset to its factory settings.
Note: The “Beep” warning tone can be turn on or turn off by SMS command.
Refer to Chapter 3.9 for details.
Chapter 2 Quick start
2.1 Install the SIM card and temperature sensor
•
Turn the power switch to “OFF” position.
•
Loosen the screw and open the socket’s SIM cover; you will see a SIM card holder.
8
TUTA S30 GSM POWER SOCKET USER MANUAL
•
•
• Push the metallic cover of the holder to “OPEN” direction and open the SIM card holder.
•
Put the SIM card on the card holder, ensuring that the beveled corner is toward the beveled corner of the SIM holder and the golden contact area is
• facing downwards.
Cover back the metallic cover and push it to “LOCK” direction. The SIM card will be fixed in the holder.
Screw the SIM cover back.
Insert the temperature sensor into the I/O port until it is seized.
2.2 GSM Power on/ off
Power on:
1. Turn the power switch to “On” position (See 7 on Figure1).
2.
Plug the TUTA S30 in an AC power socket (See 6 on Figure1).
The blue light will be flashing slowly for about 20 seconds, then blue light be
3.
4.
on constantly and a long “Beep” tone can be heard (if “Beep” warning tone is enabled).
The default state of the socket outlet is no power supply output.
Insert the plug of electronic appliance in the TUTA S30 electrical outlet (See
4 on Figure1).
M button (See 3 on Figure1) can be pressed for about 0.5 second to switch on or off the output of socket.
After adding user numbers to the socket, users can send SMS command to control the power supply output. (Refer to Chapter 3.2)
Power off:
1.
Turn the power switch to “Off” position. The blue light turns off.
2. The socket outlet can work as a normal power socket. TUTA S30 can not be controlled by SMS commands. M button is disabled.
Note:
1.
If the GSM indicator light is not constant lights, which imply the SIM card working normally, all functions of this socket are invalid.
2. Check GSM network signal of the using place:
•
The GSM network’s signal strength may affect the socket feature.
Therefore, before using, the user should ensure that TUTA S30 is used in an area with a strong GSM network signal.
•
For the first time use, the user should perform a test-run by sending
9
TUTA S30 GSM POWER SOCKET USER MANUAL
SMS to the socket. This allows the user to check the GSM network connection of the socket.
2.3 Add a Master number to the socket
The user must edit and send the following SMS to socket via his/her mobile phone (the phone number will be the Master number) in order to:
Add a Master number to the socket: #00#
Successful SMS reply
Welcome to use TUTA-S30.
Your Password is:1234.
2.4 The regulation of time
Important note
If TUTA S30 is being used for the first time, or it has been reset, the Master user must adjust the socket time according to the current time of SMS center.
Otherwise, TUTA S30 will use the original time from 00:00:00, 1 st .Jan.2004.
Method
The Master user sends following SMS message in order to:
Regulate the socket time: #152#
SIMCardNumber (1)
• The SIMCardNumber should be the SIM card number of TUTA S30.
Successful SMS reply
The socket current time is yyyy/mm/dd hh:mm.
2.5 Socket output switching on/off
Method
Method 1:To press M button 0.5 second (See 3 on Figure1).
Method 2:
The Master user sends following SMS message to socket in order to:
Switch on the socket output: #01#
Switch off the socket output: #02#
10
TUTA S30 GSM POWER SOCKET USER MANUAL
Successful SMS reply
Status: ON/OFF
Temp:23
Temp control: function ON/OFF
Schedule control: function ON/OFF
Delay control: function OFF
2.6 External power supply notification
TUTA S30 will notify the user when the external power changes. The “Beep, Beep…” tones will be heart (if enabled), also a SMS notification will be sent if the SIM card is available:
Lost external power supply:
If the plug of TUTA S30 is disconnected from external AC power or lost of the AC power occurs, all operating on TUTA S30 is de-activated, including M button and all
SMS commands. TUTA S30 will notify the user “Main electricity supply lost
Temp:**”.
Resume external power supply:
If the AC power of TUTA S30 is available again, the SMS notification will be sent to the user, i.e.” Main electricity supply restore Status: ON/OFF Temp:**”
When the external power supply is resumed, the output of TUTA S30 will keep its previous working status. For example, if the output is switched on before the external power supply cut off, the output will be switched on when the external power supply is resumed.
If the power supply is switched on and off frequently, TUTA S30 will send reminding
SMS messages.
Chapter 3 Advanced settings
3.1 Define the users
3.1.1 User authorization level
All the settings of TUTA S30 can be set or adjusted via a SMS command.
There are two mobile phone user controlling levels:
11
TUTA S30 GSM POWER SOCKET USER MANUAL
Master user:
Only one Master user has authorization to use all features of TUTA S30.
In order to enable all the functions on the socket, the Master user must store his/ her mobile number in the socket’s memory. Only one Master’s mobile number (Master number) is allowed for a socket.
Family users:
There are four Family users have authorization to use two commands of switch on or cut off the socket output.
The other mobile phone users have no authorization to use TUTA S30.
3.1.2 About the SMS Command
•
Master user’s SMS command format: #code#content#.
• Family users’ SMS command format: #code#content#password#.
•
The password must be a four-digit number.
•
The original password is 1234.
•
The maximum digits that are allows for the phone number is sixteen.
•
TUTA S30 will reply to the user after it receives the SMS command.
Note
•
The “#” symbol must not be ignored when typing an SMS command.
•
No allow any space within the commands.
3.1.3 Add a master number to the socket
Description
If TUTA S30 is being used for the first time, or TUTA S30 has been reset to factory settings, the Master user’s number must be programmed into the socket.
Method
The user must edit and send the following SMS to socket via his/her mobile phone (the phone number will be the Master number) in order to:
Add a master number to the socket: #00# (2)
Successful SMS reply
Welcome to use TUTA-S30.
Your Password is:1234..
12
TUTA S30 GSM POWER SOCKET USER MANUAL
Failed SMS reply
If a user tries to add another Master user again, TUTA S30 will send a notification via SMS stating “The master user already exists.”. The Master number should be changed. (Refer to Chapter 3.1.4)
3.1.4 Change the master number
Method
Method 1:
The Master user sends following SMS message in order to:
Change the master user’s number: #14#
NewMasterNumber
• NewMasterNumber should be the new Master user’s mobile phone number.
Method 2:
TUTA S30 should be reset to factory settings to remove old Master number before setting the new one. (Refer to Chapter 3.11)
Successful SMS reply
New master number set successfully.
Successful SMS reply will be sent to the new Master user. Then the old Master user’s number will not be able to control TUTA S30 anymore.
3.1.5 Add a family number
Up to 4 family users’ number can be stored on one socket.
Family users have the authority to send SMS command to switch on or cut off the
TUTA S30 output. The family users should remember and safeguard the socket’s
SIM number.
Method
The Master user sends following SMS message in order to:
Add a family number: #06#
FamilyNumber
Add several family numbers: #06#
FamilyNumber1
#...#
FamilyNumber4
(5)
• FamilyNumber should be the Family user’s mobile phone number.
Successful SMS reply
#******# Family numbers set successfully.
13
TUTA S30 GSM POWER SOCKET USER MANUAL
3.1.6 Check family user’s number
Refer to Chapter 3.10 Check status.
3.1.7 Delete family number
Method
The Master user sends following SMS message in order to:
Delete a family number: #113#
FamilyNumber
Delete several family numbers simultaneously: (7)
#113#
FamilyNumber1
#…#
FamilyNumber4
#
Delete all family numbers: #113# (8)
Successful SMS reply
#******# Family number has been deleted.
Failed SMS reply
#******# The family number does not exist.
3.2 Switching on/off the socket output manually
Description
•
•
When the socket output is switching on, TUTA S30 offers power supply for electronic appliance which being connected with it; the red indicator light is lighted constantly. Otherwise, TUTA S30 has no power supply for electronic appliance and the red light is turned off.
Note: If the socket output status is changed manually (including pressing the
M button, sending SMS, making phone call), the preset timing, delaying or temperature control of the socket will be invalid automatically and a SMS notification message will be sent to the Master, but the setting time range and temperature range parameters will be saved until TUTA S30 is reset to factory settings.
3.2.1 Switching on/off by SMS
Method
14
TUTA S30 GSM POWER SOCKET USER MANUAL
The Master user sends following SMS message in order to:
Switch on the socket output manually: #01# (9)
Cut off the socket output manually: #02# (10)
The Family users send following SMS message in order to:
Switch on the socket output manually: #01#
Password
Cut off the socket output manually: #02#
Password
(12)
•
•
Password should be 4 digits password number. Default 1234.
SMS reply will be also sent to Master user when Family users use these two commands to change the socket output successfully.
Successful SMS reply
Status: ON/OFF
Temp:**
Temp control: function ON/OFF
Schedule control: function ON/OFF
Delay control: function ON/OFF
3.2.2 Switching on/off by M button
Keep press M button on the TUTA S30 for half a second. The OUTPUT indecator light will turn on or off to indicate that TUTA S30 output is switching on or off.
The SMS reply is same with Chapter 3.2.1.
3.2.3 Switching on/off by calling
Description
If the Master user calls TUTA S30, the socket output will be switched on or cut off automatically when the user hears the ring tone in the phone. The calling will be hung up automatically if the user doesn’t hang up the call.
Method
The Master user sends following SMS message in order to:
Enable switching on/off the output by calling: #18#1# (13)
Disable switching on/off the output by calling (Default): #18#0# (14)
Successful SMS reply
Control the socket power output status by calling activated /de-activated.
15
TUTA S30 GSM POWER SOCKET USER MANUAL
3.3 Delayed-switch on/off the socket output
Description
•
•
•
•
The output of TUTA S30 can be set to delay switch on or off for a period with
SMS commands.
When the “delayed-switch on/off the socket” function is applied, the preset
“timed switch on the output” function will be invalid at once.
When the “delayed switch on the socket” command is received and if the socket output is switched on, the socket output will be switched off immediately and be switch on again as the setting delayed time is reaching.
Contrarily, if the socket output is switched off, the output will remain switching off until the setting delayed time is reaching. Afther switching on the output, the following SMS reply will be sent:
Status: ON
Delay control: function OFF
When the “delayed switch off the socket” command is received and if the the socket output is switched on, the socket output will remain the switch on state and be switched off as the setting delayed time is reaching. If the socket output is switched off, it will be switched on immediately and be switch off again when reaching the setting delayed time. After switching off the socket output, the following SMS reply will be sent:
Status: OFF
Delay control: function OFF
Method
The Master user sends following SMS message in order to:
Delay switching on the output after a certain minutes: #138#1# Minutes
Delay switching off the output after a certain minutes: #138#0# Minutes (16)
•
•
Minutes are time parameters, its range is 0-720,
When Minutes is 0, the “delayed switch on/off the socket” function will be invalid, but the current output status won’t be changed.
Successful SMS reply
Status: ON/OFF
Output will switch off/on after * minutes.
16
TUTA S30 GSM POWER SOCKET USER MANUAL
3.4 Timed switching on the socket output
3.4.1 Enable timing switching on the output
Description
•
•
The output of TUTA S30 can be set to switch on for a duration and then be switch off after the duration.
If the socket output status is changed manually (including pressing M button, sending SMS and making phone call), the preset timing, delaying or temperature control of the socket will be invalid automatically, but the setting time range parameters will be saved until TUTA S30 is reset to factory settings. If these functions need to be restarted, the following SMS commands must be set: Timing #128#1#, Temperature control #159#1#,
“delayed switch on/off the socket” commands need to be reset.
Method
The Master user sends following SMS message in order to:
Enable timing switch on the output: #128#1# (17)
Successful SMS reply
Schedule control: function ON
WorkDay, StartTime-EndTime
If the value of the “WorkDay, StartTime, EndTime” on the SMS reply are all 0, it means the time duration has not been set. (Refer to 3.4.2)
Then TUTA S30 will keep switching on or off the output automatically according to the schedule settings.
3.4.2 Set time period to switch on the output
Description
After successful setting of time duration to switch on the socket output, the schedule parameter will be saved on the socket until TUTA S30 is reset to factory settings.
But the “timed switch on the output” feature is applied only when command 17 be set.
17
TUTA S30 GSM POWER SOCKET USER MANUAL
Method
The Master user sends following SMS message in order to:
Set time period to switch on the output: (18)
•
#129#
WorkDay
# # #
WorkDay: one digit, the values lie in the range of “0” to “8”.
The following table contains the descriptions of each value:
•
Value
0
1
2
6
7
8
3
4
5
Corresponding day
Everyday
Monday
Tuesday
Wednesday
Thursday
Friday
Saturday
Sunday
Monday to Friday
StartTime and EndTime: Be consists of 4 digits (hh:mm) and works on a 24 hour clock. The StartTime and EndTime should be in the same day, and the
EndTime must be later than StartTime.
•
•
The socket output will switch on at the StartTime and cut off at the EndTime.
For example: #129#1#0000#2130#
2130 means time 9:30PM.
,
0000 means time 00:00(hh:mm)AM,
Successful SMS reply
Schedule control: function ON/OFF
WorkDay, StartTime-EndTime
3.4.3 Disable timing switching on the output
Method
The Master user sends following SMS message in order to:
Disable timing switch on the output: #128#0# (19)
Successful SMS reply
Schedule control: function OFF
WorkDay, StartTime-EndTime.
18
TUTA S30 GSM POWER SOCKET USER MANUAL
3.5 Auto-control the socket output by temperature
3.5.1 Enable auto-controlled by temperature
Description
•
The external temperature sensor must be inserted into the I/O port of TUTA
S30. The output status of the socket can be controlled by the environmental
• temperature automatically.
If users don’t open the “timed switch on the socket” or “delayed switch on/off the socket” functions, the socket will control to switch on or cut off the output according to temperature setting.
•
If users open the “timed switch on the socket” or “delayed switch on/off the socket” functions, the temperature control function will only be valid when
• power output is switch on (including timed switch on or delayed switch on time period).
For example: TUTA S30 is used for the power control of the heating apparatus. If users set the socket output on when indoor temperature is bellow 20 degrees and off when indoor temperature is above 28 degrees.
Meanwhile, users set the TUTA S30 output is on from 9am to 5pm. In this case, the socket will control to switch on or off the output according to indoor temperature automatically from 9am to 5pm duration.
Method
The Master user sends following SMS message in order to:
Enable auto-control the output by temperature: #159#1# (20)
Successful SMS reply
Status: ON/OFF
Temp control: function ON
Temp: **
Mode: Heating/Cooling
Range: LowTemp ~ HighTemp
Then TUTA S30 can switch on or off the output automatically according to the temperature range setting.
19
TUTA S30 GSM POWER SOCKET USER MANUAL
3.5.2 Set temperature range to switch on/off the output
Description
After successful setting of temperature range, the temperature parameter will be saved on the socket until TUTA S30 is reset to factory settings.
But the “Auto-controlled by temperature” feature is applied only when command
20 be set.
Method
The Master user sends following SMS message in order to:
Set temperature range to switch on/off the output: (21)
#159#
Mode
# # #
•
•
Mode is the control selection:
For coldness, mode=1. For warmness, mode=0.
LowTemp and HighTemp means temperature value, the range is -10 to 50 centigrade degree, if LowTemp equals to HighTemp, constant temperature control will be actived.
•
Temperature unit is degree Celsius.
•
Example 1: set commands: #159#0#10#20#, if the environmental temperature is 5 degrees (bellow the limitation of 10 degrees in the command), the socket
• output will be switched on to power heating apparatus; and if the environmental temperature is 24 degrees (above the limitation of 20 degrees in the command), the socket output will be switched off and the heating apparatus stops working;
Example 2: set commands: #159#1#10#20#, if the environmental temperature is 26 degrees (above the limitation of 20 degrees in the command), the socket output will be switched on to power cooling apparatus; and when the environmental temperature is 7 degrees (bellow the limitation of 10 degrees in the command), the socket output will be off, cooling apparatus stops working.
Successful SMS reply
Status: ON/OFF
Temp control: function ON/OFF
Temp: **
Mode: Heating/Cooling
Range: LowTemp ~ HighTemp
20
TUTA S30 GSM POWER SOCKET USER MANUAL
3.5.3 Disable auto-controlled by temperature
Method
The Master user sends following SMS message in order to:
Disable auto-control the output by temperature: #159#0# (22)
Successful SMS reply
Status: ON/OFF
Temp control: function OFF
Temp: **
Mode: Heating/Cooling
Range: LowTemp ~ HighTemp
3.6 Temperature alarm
3.6.1 Over-temperature alarm
Description
A range of temperature can be pre-set onto the socket. In this case, if the surroundings temperature is detected out of the pre-set temperature range, the
TUTA S30 will auto-send the SMS alarm message to master’s mobile phone.
This feature depends on the temperature sensor.
Method
The Master user sends following SMS message in order to:
Enable over-temperature alarm: #170#1# (23)
Set limits of temperature: #170# MinTemp MaxTemp (24)
• MinTemp and MaxTemp: The values can be set within the range of -10 to 50 centigrade degree.
Default MinTemp is 20 and MaxTemp is 30 centigrade degree
.
Disable the alarm upon going beyond limits temperature: #170#0# (25)
Successful SMS reply
Temperature alert: function ON/OFF
21
TUTA S30 GSM POWER SOCKET USER MANUAL
Min Temp.:**
Max Temp.: **.
3.6.2 Temperature rapid-changing alarm
Description
A time period value and temperature changing value can be pre-set onto the socket. In this case, if the surroundings temperature change to the pre-set value within the pre-set time period, a SMS alarm message will be auto-sent to master’s mobile phone.
This feature depends on the temperature sensor.
Method
The Master user sends following SMS message in order to:
Enable the temperature rapid changing alarm: #160#1# (26)
Set time period and temperature changing value: #160# Temp # #
•
•
Temp: The values lie in the range of 1 to 50 centigrade degree.
Time: The values lie in the range of 1 to 300 minutes.
Default Temp is 2 degree and Time is 1 minute
.
Disable the temperature rapid changing alarm: #160#0# (28)
Successful SMS reply
Fast temperature changing.: function ON/OFF
Delta:**
Time:* minutes
3.7 SMS notification upon the socket output changing
Description
TUTA S30 will default notify the user when the state of the socket output is changed with a SMS notification. The Master user can enable/disable this SMS notification.
Method
The Master user sends following SMS message in order to:
22
TUTA S30 GSM POWER SOCKET USER MANUAL
SMS notification upon the socket output changing (Default): #11#1# (29)
No SMS notification upon the socket output changing: #11#0# (30)
Successful SMS reply
Set no SMS notification when socket output changed.
Set SMS notification once socket output changed.
3.8 SMS notification upon extension power supply changing
Description
TUTA S30 will default notify the user when the state of the extension power supply is changed with a SMS notification. For example:
Main electricity supply lost
Temp:** or
Main electricity supply restore
Status: ON
Temp:**
The Master user can enable/disable this SMS notification.
Method
The Master user sends following SMS message in order to set:
SMS notification upon the power supply changing (Default): #12#1# (31)
No SMS notification upon the power supply changing: #12#0# (32)
Successful SMS reply
(No) SMS notification upon main electricity supply changing.
3.9 “Beep” warning tone
Description
A “Beep” warning tone will be sounded if the work state of TUTA S30 is changed.
23
TUTA S30 GSM POWER SOCKET USER MANUAL
The “Beep” warning tone is default turning off. The Master user can enable it by sending SMS command.
Method
The Master user sends following SMS message in order to:
Enable the “Beep” warning tone: #19#1# (33)
Disaable the “Beep” warning tone (Default): #19#0# (34)
Successful SMS reply
Beep alarm activated/de-activated.
3.10 Check status
Method
The Master user sends following SMS message in order to:
Check socket operating status:
#07# (35)
After receiving the SMS commands, TUTA S30 will reply one SMS message of socket status checking:
Number:***********,**********
Status: ON/OFF
TEMP:**
Temp control:function ON/OFF
Schedule control:function ON/OFF
Delay control:function ON/OFF
Check socket output status: #000# (36)
After receiving the SMS commands, TUTA S30 will reply one SMS message of socket output status:
Status: ON
Temp:23.
Check “delayed switch on/off the socket” parameters: #138# (37)
After receiving the SMS commands, TUTA S30 will reply one SMS message of
“Delayed switch on/off the socket” parameters checking:
Status: ON/OFF
Output will switch off/on after ** minutes.
Check “Timing switch on the socket” parameters: #128# (38)
After receiving the SMS commands, TUTA S30 will reply one SMS message of
24
TUTA S30 GSM POWER SOCKET USER MANUAL
“Timing switch on the socket” parameters:
Schedule control: function ON/OFF
WorkDay, StartTime-EndTime.
Check “Temperature control” parameters: #159# (39)
After receiving the SMS commands, TUTA S30 will reply one SMS message of temperature parameters checking:
Status: ON/OFF
Temp control: function ON/OFF
Temp: **
Mode: Heating/Cooling
Range: LowTemp ~ HighTemp
If “No temperature sensor connected” be received, it means TUTA S30 cannot detect the temperature sensor. User needs to check if the temperature sensor is inserted to the I/O port.
Check “temperature rapid changing alarm” parameters: #160# (40)
After receiving the SMS commands, TUTA S30 will reply one SMS message of parameters. It means SMS alarm message will be sent upon the surrounding temperature changes “Delta” centigrade degree within * minutes:
Fast temperature changing.: function ON/OFF
Delta: *
Time: * minutes
Check “over-temperature alarm limits” parameters: #170# (41)
After receiving the SMS commands, TUTA S30 will reply one SMS message of parameters. It means SMS alarm message will be sent upon temperature reaches MinTemp or MaxTemp centigrade degree:
Temperature alert: function OFF
Min Temp.: **
Max Temp.: **
3.11 Resetting the socket
Description
•
•
This function resets all programmed settings to their original values, including cleaning all user number, timing parameter and temperature parameter.
If the setting status is wrong or the malfunctions can’t be corrected, users can restore the socket to its original status to make it work normally.
25
TUTA S30 GSM POWER SOCKET USER MANUAL
Note
This function needs to be used carefully as it also erases all setting values.
Method
Method 1: Press the side M button of the device for 5 seconds.
Method 2: The Master user sends following SMS message to TUTA S30 in order to:
Reset the socket: #08# (42)
Successful SMS reply
Reset the socket to factory setting successfully.
A long “Beep” tone (if enabled) will be heard and it means resetting the socket successfully.
Chapter 4 Maintenance
•
•
If TUTA S30 does not in use for long time, it should be powered off.
Store and use the remote socket in suitable temperature. Too high or too low temperature will likely to damage the socket.
•
Try to keep the TUTA S30 and all its accessories dry. Do not store and use it in the bathroom, or other place with high humidity. Do not allow pour water or other liquids into the socket, otherwise, it might cause malfunctions.
•
Do not store and use the socket in dusty.
•
Do not use alcohol, acetone and other similar solvents to clean it. Wipe it with soft-wet cloth.
•
Do not attempt to open it except as instructed. If the socket does not work normally, try to resolve it as the guide of the "general troubleshooting", if to the problem can not be solved, contact with the dealer immediately.
Chapter 5 General Troubleshooting
No.
General Trouble
1 Power indicator light turns off
2 GSM indicator light turns off
Possible Reason
No power input.
Can’t find or identify the SIM card.
The power switch is OFF.
3 Socket output cannot be changed by M button.
No power input.
The power switch is OFF.
26
Solution
Check TUTA S30’s external
AC power is available.
SIM card no install properly:
Power off the socket and check it again.
Power on the socket.
Check TUTA S30’s external
AC power is available.
TUTA S30 GSM POWER SOCKET USER MANUAL
No.
General Trouble
5 Socket didn’t response of any operation.
6 After power on the socket, GSM indicator keeps flashing.
TUTA S30 work abnormally.
Network signal weak or network busy.
Possible Reason
4 All functions disable
(Indicator is working)
Caller ID presentation do not active, insufficient fee of the SIM card.
SIM card PIN code actives.
Solution
Power on the socket.
Contact network provider to active SIM card function. Pay for the card.
Switch off the power, check
SIM card, or reset factory setting.
If mobile phone’s signal is weak too, place the socket at other place with strong signal and try again.
Close the PIN code.
SIM card invalid.
Contact with local operator to check of it.
7 The master number already exists.
Other master is already set in the socket.
Change Master number or recover to factory default setting.
8 Invalid format. Please check and try again.
Invalid command.
9 No authorization user
Refer to the user manual.
Use the Master mobile phone to try the command again.
Note: If the problem can’t be solved with above guidelines, contact to your local distributor or after service center.
Chapter 6 Main Technical Parameters
Input power socket 110~230V/50HZ, CEE 7/7 hybrid Schuko/French plug
Output power socket relay 110~ 230V/50HZ, 230V/30A(30s),15A long-term,
CEE7/4 German “Schuko”
Operating temperature -10
℃~+50℃
Store temperature -20
℃~+60℃
Relative humidity 10-90%,without condensation
Communication protocols GSM PHASE 2/2+ (including data operation)
Data interface GSM SIM 1.8V/3.0V socket
External temperature sensor -10 ~50
℃
GSM working band EGSM900,DCS1800
27
TUTA S30 GSM POWER SOCKET USER MANUAL
Appendix: SMS commands list
Category
Time
Define the users
Switching on/off output manually
Function Command
Regulate the socket time
Add a master number to the socket
Change the master user’s number
(1) #152#SIMCardNumber#
(2) #00#
(3) #14#
NewMasterNumber
#
Add a family number
Add several family numbers
(4) #06#
(5) #06#
FamilyNumber
#
#...# FamilyNumber4 #
Delete a family number
Delete several family
(6) #113#
(7) #113#
FamilyNumber #
FamilyNumber1 numbers simultaneously
Delete all family numbers (8) #113#
#…# FamilyNumber4 #
Master user switches on the socket output manually
Master user cuts off the socket output manually
Family user switches on the socket output manually
(9) #01#
(10)#02#
(11) #01#
Password
#
Family user cuts off the socket output manually
Enable switching on/off the output by calling
(12) #02#
Password
#
(13) #18#1#
Delay control
Disable switching on/off the output by calling (Default)
Delay switching on the output after a certain minutes
Delay switching off the output after a certain minutes
Timing control Enable timing switch on the output
Temperature control
Set time period to switch on the output
Disable timing switch on the output
Enable auto-control the output by temperature
Set temperature range to switch on/off the output
Disable auto-control the output by temperature
Overtemperature alarm
Temperature rapidchanging alarm
Enable the over-temperature alarm
Set limits of temperature
Disable the overtemperature alarm
Enable the temperature rapid-changing alarm
Set time period and temperature changing value
(14) #18#0#
(15) #138#1#
(16) #138#0#
(17) #128#1#
(18) #129#
(19) #128#0#
(20) #159#1#
(21) #159#
(22) #159#0#
(23) #170#1#
(24) #170#
(25) #170#0#
(26) #160#1#
(27) #160#
Disable the temperature rapid-changing alarm
(28) #160#0#
SMS notification upon the (29) #11#1#
Minutes
Minutes
WorkDay
Mode
MinTemp
Temp
#
#
#
#
#
#
#
28
#
#
#
#
#
Category
SMS notification
“Beep” warning tone
Check status
Reset to factory settings
TUTA S30 GSM POWER SOCKET USER MANUAL
Function Command
socket output changing
(Default)
No SMS notification upon the socket output changing
SMS notification upon the power supply changing
(Default)
No SMS notification upon the power supply changing
Enable the “Beep” warning tone
Disaable the “Beep” warning tone (Default)
Check socket operating status
(30) #11#0#
(31) #12#1#
(32) #12#0#
(33) #19#1#
(34) #19#0#
(35) #07#
Check Socket output status (36) #000#
Check “Delayed switch (37) #138# on/off the socket” parameters
Check “Timed switch on the socket” parameters
(38) #128#
Check “Temperature control” parameters
Check “temperature rapidchanging alarm” parameters
(39) #159#
(40) #160#
Check “over-temperature alarm” parameters
Reset the socket
(41) #170#
(42) #08#
Xiamen Youthnet Co., Ltd.
Add: 10F, No.56 Guanri road, Software park II, Xiamen, Fujian, China. 361009 http://www.i-tuta.com.
TEL: +86-592-6300656
FAX: +86-592-6022220
29
advertisement
Key Features
- Remote control via SMS
- Manual on/off via button
- Scheduled on/off
- Temperature-based control
- Temperature alarms
- Power supply notification
- Up to 5 user accounts
- Delayed on/off
- Time synchronization