(61-2) 9672 1233
(
Solution 844/862/880
Installation Manual
Copyright
2001 by Electronics Design and Manufacturing Pty Limited,
SYDNEY, AUSTRALIA
Document Part Number MA8XXI
DOCUMENT ISSUE 1.40
Printed 10 May 2001
This documentation is provided to suit
Solution 844/862/880
Control Panel (CC404/CC406/CC408)
Firmware Revision 1.00 – 1.09
Hardware Revision A - J
Alarm Link required = 2.74 or higher
Control Panel Software Version 1.00 – 1.09 = S404_V10
= S406_V10
= S408_V10
Copyright Notice
All rights reserved. No part of this publication may be reproduced, transmitted or stored in a retrieval system in any form or by any means, electronic, mechanical, photocopying, recording, or otherwise, without the prior written permission of
Electronics Design and Manufacturing Pty Limited.
Trademarks
Throughout this document trademark names may have been used. Rather than put a trademark symbol in every occurrence of a trademark name, we state that we are using the names only in an editorial fashion and to the benefit of the trademark owner with no intention of infringement of the trademark.
Notice of Liability
While every precaution has been taken in the preparation of this document, neither Electronics Design and Manufacturing
Pty Limited nor any of its official representatives shall have any liability to any person or entity with respect to any liability, loss or damage caused or alleged to be caused directly or indirectly by the information contained in this book.
Electronics Design and Manufacturing Pty Limited reserves the right to make changes to features and specifications at any time without prior notification in the interest of ongoing product development and improvement.
318#7(>;(?"'%7'%0(
Introduction _____________________________________________________________________ 17
Introduction __________________________________________________________________________ 18
Solution 844 Features __________________________________________________________________ 19
Solution 862 Features __________________________________________________________________ 20
Solution 880 Features __________________________________________________________________ 21
Quick Start___________________________________________________________________________ 22
Solution 844 Zone Defaults _____________________________________________________________________ 24
Solution 862 Zone Defaults _____________________________________________________________________ 24
Solution 880 Zone Defaults _____________________________________________________________________ 24
Zone Types __________________________________________________________________________________ 25
Programming____________________________________________________________________ 27
Programming_________________________________________________________________________ 28
Programming With The Remote Codepad _________________________________________________ 29
Programming With The Hand Held Programmer___________________________________________ 31
Programming With The Programming Key________________________________________________ 33
Programming Option Bits ______________________________________________________________ 34
Installer’s Programming Commands _____________________________________________________ 35
Command 958 - Enable/Disable Zone Status Mode ___________________________________________________ 36
Command 959 - Test Programming Key ___________________________________________________________ 37
Command 960 - Exit Installer's Programming Mode __________________________________________________ 39
Command 961- Reset Control Panel Back To Factory Default Settings____________________________________ 39
Command 962 - Copy Control Panel Memory To Programming Key _____________________________________ 40
Command 963 - Copy From Programming Key To Control Panel________________________________________ 41
Command 964 - Erase Programming Key __________________________________________________________ 42
Command 965 - Set Up Domestic Dialling Format ___________________________________________________ 43
Command 966 - Enable/Disable Automatic Stepping Of Locations_______________________________________ 44
Command 999 - Display Panel Type Or Software Version Number ______________________________________ 46
Disable Factory Default ________________________________________________________________________ 47
Defaulting The Control Panel ____________________________________________________________________ 48
Codepad Indicators _______________________________________________________________ 49
CP5 Eight Zone LED Codepad __________________________________________________________ 50
Zone Indicators _______________________________________________________________________________ 50
AWAY Indicator______________________________________________________________________________ 50
STAY Indicator_______________________________________________________________________________ 51
MAINS Indicator _____________________________________________________________________________ 51
FAULT Indicator _____________________________________________________________________________ 51
Audible Indicators_____________________________________________________________________________ 52
CP5 Eight Zone LCD Codepad __________________________________________________________ 53
Zone Indicators _______________________________________________________________________________ 53
AWAY Indicator______________________________________________________________________________ 53
STAY Indicator_______________________________________________________________________________ 54
System Disarmed _____________________________________________________________________________ 54
MAINS Indicator _____________________________________________________________________________ 54
Zone Isolating Mode ___________________________________________________________________________ 54
FAULT Indicator _____________________________________________________________________________ 55
Programming Mode ___________________________________________________________________________ 55
Off Indicator/Zone Sealed _______________________________________________________________________ 55
On Indicator/Zone In Alarm _____________________________________________________________________ 55
Audible Indicators_____________________________________________________________________________ 56
CP5 Master Partitioned LED Codepad____________________________________________________ 57
Zone Indicators _______________________________________________________________________________ 57
Area On/Off Indicators _________________________________________________________________________ 57
Area Display Indicators ________________________________________________________________________ 58
Status Indicators ______________________________________________________________________________ 58
PARTIAL Indicator _________________________________________________________________________ 58
AUX Indicator _____________________________________________________________________________ 58
MAINS Indicator ___________________________________________________________________________ 59
FAULT Indicator ___________________________________________________________________________ 59
Audible Indicators __________________________________________________________________________ 59
System Operations ________________________________________________________________ 61
System Operations _____________________________________________________________________ 62
Arming The System In AWAY Mode _____________________________________________________________ 62
Forced Arming _____________________________________________________________________________ 62
Disarming The System From AWAY Mode ________________________________________________________ 63
Arming The System In STAY Mode 1 _____________________________________________________________ 64
Entry Guard Timer For STAY Mode ____________________________________________________________ 64
Forced Arming _____________________________________________________________________________ 65
Disarming The System From STAY Mode 1 ________________________________________________________ 66
Arming The System In STAY Mode 2 _____________________________________________________________ 67
Entry Guard Timer For STAY Mode ____________________________________________________________ 67
Forced Arming _____________________________________________________________________________ 67
Disarming The System From STAY Mode 2 ________________________________________________________ 68
Codepad Duress Alarm_________________________________________________________________________ 69
Codepad Panic Alarm __________________________________________________________________________ 69
Codepad Fire Alarm ___________________________________________________________________________ 69
Codepad Medical Alarm________________________________________________________________________ 69
Isolating Zones ________________________________________________________________________ 70
Standard Isolating ___________________________________________________________________________ 71
Code To Isolate_____________________________________________________________________________ 72
Fault Analysis Mode____________________________________________________________________ 73
Fault Descriptions _____________________________________________________________________________ 74
Low Battery _______________________________________________________________________________ 74
Date and Time______________________________________________________________________________ 74
Sensor Watch ______________________________________________________________________________ 74
Horn Speaker Monitor _______________________________________________________________________ 74
Telephone Line Fault ________________________________________________________________________ 74
E
2
Fault ___________________________________________________________________________________ 74
Fuse Fail __________________________________________________________________________________ 75
Communication Failure ______________________________________________________________________ 75
AC Mains Failure ___________________________________________________________________________ 76
Remote Radio Transmitter Operations ________________________________________________ 77
Remote Radio Transmitter Operations ____________________________________________________ 78
Indications Upon Remote Radio Transmitter Operations _______________________________________________ 78
Remote Radio User Code Priority Levels___________________________________________________________ 78
Changing Or Deleting Remote Radio User Codes ____________________________________________________ 79
2 Channel Radio Remote Hand Held Transmitter Operations ___________________________________________ 81
Arming In AWAY Mode _____________________________________________________________________ 81
Disarming From AWAY Mode ________________________________________________________________ 81
Arming In STAY Mode 1 _____________________________________________________________________ 81
Disarming From STAY Mode 1 ________________________________________________________________ 81
Panic Alarm _______________________________________________________________________________ 81
4 Channel Radio Remote Hand Held Transmitter Operations ___________________________________________ 82
Arming In AWAY Mode _____________________________________________________________________ 82
Disarming From AWAY Mode ________________________________________________________________ 82
Arming In STAY Mode 1 _____________________________________________________________________ 82
Disarming From STAY Mode 1 ________________________________________________________________ 82
Panic Alarm _______________________________________________________________________________ 82
Turning Output 1 ON ________________________________________________________________________ 83
Turning Output 1 OFF _______________________________________________________________________ 83
Turning Output 2 ON ________________________________________________________________________ 83
Turning Output 2 OFF _______________________________________________________________________ 83
System Functions_________________________________________________________________ 85
System Functions______________________________________________________________________ 86
Installer Code Functions ________________________________________________________________________ 86
Reserved __________________________________________________________________________________ 86
Set The Number Of Days Until The First Test Report _______________________________________________ 87
Changing Domestic Phone Numbers ____________________________________________________________ 88
Change Telco Arm/Disarm Sequence ____________________________________________________________ 90
Setting STAY Mode 2 Zones __________________________________________________________________ 95
Satellite Siren Service Mode ___________________________________________________________________ 96
Turning Telephone Monitor Mode On/Off ________________________________________________________ 97
Walk Test Mode ____________________________________________________________________________ 97
Event Memory Recall Mode ___________________________________________________________________ 98
Reserved __________________________________________________________________________________ 98
Master Code Functions_________________________________________________________________ 99
Arm or Disarm Both Areas At The Same Time ____________________________________________________ 99
Changing and Deleting User Codes ____________________________________________________________ 100
Changing and Deleting Remote Radio User Codes_________________________________________________ 102
Changing Domestic Phone Numbers ___________________________________________________________ 104
Change Telco Arm/Disarm Sequence ___________________________________________________________ 106
Setting STAY Mode 2 Zones _________________________________________________________________ 111
Turning Outputs On/Off _____________________________________________________________________ 112
Setting The Date and Time ___________________________________________________________________ 114
Walk Test Mode ___________________________________________________________________________ 115
Event Memory Recall Mode __________________________________________________________________ 116
Reserved _________________________________________________________________________________ 116
User Code Functions __________________________________________________________________ 117
Arm or Disarm Both Areas At The Same Time ___________________________________________________ 117
Hold Down Functions _________________________________________________________________ 118
Arm The System In AWAY Mode _____________________________________________________________ 118
Arm The System In STAY Mode 1_____________________________________________________________ 118
Arm The System In STAY Mode 2_____________________________________________________________ 119
Horn Speaker Test__________________________________________________________________________ 119
Bell Test _________________________________________________________________________________ 119
Strobe Test _______________________________________________________________________________ 119
Turning Day Alarm On and Off _______________________________________________________________ 120
Fault Analysis Mode ________________________________________________________________________ 120
Initiate A Modem Call ______________________________________________________________________ 121
Reset Latching Outputs ______________________________________________________________________ 121
Codepad Buzzer Tone Change ________________________________________________________________ 122
Send Test Report ___________________________________________________________________________ 122
Remote System __________________________________________________________________ 123
Operations Via Telephone_________________________________________________________ 123
Remote Arming Via The Telephone _____________________________________________________ 124
Alarm Link Operations ___________________________________________________________ 125
Alarm Link Software _________________________________________________________________ 126
Remote Connect _____________________________________________________________________________ 126
Remote Connect With Customer Control ________________________________________________________ 126
Remote Connect Without Call Back Verification __________________________________________________ 127
Remote Connect With Call Back Verification ____________________________________________________ 127
Direct Connect ____________________________________________________________________________ 128
Alarm Link Options __________________________________________________________________________ 129
Enable Upload/Download Via Alarm Link _______________________________________________________ 129
Enable Alarm Link Call Back _________________________________________________________________ 129
Terminate Alarm Link Connection On Alarm ____________________________________________________ 129
Use External Modem Module (CC811) For Alarm Link Operations ___________________________________ 129
Domestic Dialling________________________________________________________________ 131
Domestic Dialling Format ______________________________________________________________ 132
Domestic Dialling Function ____________________________________________________________________ 132
Acknowledge Domestic Dialling ______________________________________________________________ 132
Setting Up and Programming Domestic Reporting __________________________________________________ 133
Disable Domestic Dialling ___________________________________________________________________ 134
Dialler Reporting Formats_________________________________________________________ 135
Transmission Formats _________________________________________________________________ 136
Contact ID Format ___________________________________________________________________________ 136
Point ID Codes ______________________________________________________________________________ 137
4+2 Reporting Format_________________________________________________________________________ 138
Basic Pager Reporting Format __________________________________________________________________ 139
Basic Pager Display Information ________________________________________________________ 140
Subscriber ID Number ________________________________________________________________________ 140
Zone Status _________________________________________________________________________________ 140
System Status _______________________________________________________________________________ 140
Dialler Information ______________________________________________________________ 141
Dialler Information ___________________________________________________________________ 142
Primary Telephone Number For Receiver 1 ________________________________________________________ 143
Secondary Telephone Number For Receiver 1 ______________________________________________________ 143
Handshake Tone For Receiver 1_________________________________________________________________ 144
Transmission Format For Receiver 1 _____________________________________________________________ 145
Subscriber ID Number For Receiver 1 ____________________________________________________________ 145
Primary Telephone Number For Receiver 2 ________________________________________________________ 146
Secondary Telephone Number For Receiver 2 ______________________________________________________ 146
Handshake Tone For Receiver 2_________________________________________________________________ 147
Transmission Format For Receiver 2 _____________________________________________________________ 148
Subscriber ID Number For Receiver 2 ____________________________________________________________ 148
Dialling Format______________________________________________________________________________ 149
Reserved ___________________________________________________________________________________ 149
Telco Arming Sequence _______________________________________________________________________ 150
Telco Arming – Call Forward Immediate On _____________________________________________________ 150
Telco Arming – Call Forward No Answer On ____________________________________________________ 150
Telco Disarming Sequence _____________________________________________________________________ 151
Telco Arming – Call Forward Immediate Off ____________________________________________________ 151
Telco Arming – Call Forward No Answer Off ____________________________________________________ 151
Call Back Telephone Number___________________________________________________________________ 151
Ring Count _________________________________________________________________________________ 152
Answering Machine Bypass ____________________________________________________________________ 152
Telephone Line Fault Options __________________________________________________________________ 153
Operate The FAULT Indicator When Telephone Line Fails _________________________________________ 153
Sound Speaker, Bell and Strobe When The System Is Armed ________________________________________ 153
Sound Speaker, Bell and Strobe When The System Is Disarmed ______________________________________ 153
Reserved _________________________________________________________________________________ 153
Ring Burst Time _____________________________________________________________________________ 154
Dialler Options __________________________________________________________________ 155
Programming Option Bits ______________________________________________________________ 156
Dialler Options 1 ____________________________________________________________________________ 157
Dialler Reporting Functions Allowed ___________________________________________________________ 157
Disabled = Disable All Dialler Reporting Functions _______________________________________________ 157
Remote Arming Via The Telephone Allowed ____________________________________________________ 157
Answering Machine Bypass Only When Armed __________________________________________________ 157
Use Bell 103 For FSK Format (Disabled = CCITT V21)____________________________________________ 157
Dialler Options 2 ____________________________________________________________________________ 158
Open/Close Reports Only If Previous Alarm _____________________________________________________ 158
Open/Close Reports For STAY Mode 1 and STAY Mode 2 _________________________________________ 158
Delay Siren Until Transmission Complete _______________________________________________________ 158
Extend Time To Wait For Handshake From 30 - 55 Seconds ________________________________________ 158
Dialler Options 3 _____________________________________________________________________________ 159
Set DTMF Dialling Pulses To 1 Digit/Second ____________________________________________________ 159
Reserved _________________________________________________________________________________ 159
Change Decadic Dialling To 60/40 _____________________________________________________________ 159
Reserved _________________________________________________________________________________ 159
Alarm Link Options __________________________________________________________________________ 160
Upload/Download Allowed___________________________________________________________________ 160
Call Back Phone Number Required For Upload/Download __________________________________________ 160
Terminate Upload/Download On Alarm _________________________________________________________ 160
External Modem Module (CC811) Required For Upload/Download ___________________________________ 160
User Codes _____________________________________________________________________ 161
Access Codes ________________________________________________________________________ 162
Installer Code _______________________________________________________________________________ 162
User Codes _________________________________________________________________________________ 163
Solution 844/862 User Codes ___________________________________________________________________ 164
Solution 880 User Codes_______________________________________________________________________ 164
User Code Priority ___________________________________________________________________________ 165
Arm and Disarm ___________________________________________________________________________ 165
Arm Only ________________________________________________________________________________ 165
Arm and Disarm + Open/Close Reports _________________________________________________________ 165
Arm Only + Closing Reports _________________________________________________________________ 165
Arm and Disarm + Code To Isolate ____________________________________________________________ 166
Arm and Disarm + Code To Isolate + Open/Close Reports __________________________________________ 166
Arm and Disarm + Master Code Functions_______________________________________________________ 166
Arm and Disarm + Master Code Functions + Open/Close Reports ____________________________________ 166
Arm and Disarm + Master Code Functions + Code To Isolate ________________________________________ 166
Arm and Disarm + Master Code Functions + Code To Isolate + Open/Close Reports______________________ 166
Zone Information _______________________________________________________________ 167
Day Alarm Zones ____________________________________________________________________________ 168
Day Alarm Resetting________________________________________________________________________ 168
Day Alarm Latching ________________________________________________________________________ 168
Day Alarm Operation _________________________________________________________________________ 169
EOL Resistor Value __________________________________________________________________________ 170
Connections Of Split EOL Resistors Using N/C Contacts _____________________________________________ 171
Connections Of Split EOL Resistors Using N/O Contacts _____________________________________________ 172
Zone Programming ___________________________________________________________________ 173
Zone Operating Information ____________________________________________________________________ 173
Zone Options________________________________________________________________________________ 173
Zone Reporting Information ____________________________________________________________________ 173
Solution 844 Zones Defaults ____________________________________________________________________ 174
Solution 862 Zones Defaults ____________________________________________________________________ 174
Solution 880 Zones Defaults ____________________________________________________________________ 174
Zone Types _________________________________________________________________________________ 175
Instant Zone_______________________________________________________________________________ 175
Handover Zone ____________________________________________________________________________ 175
Delay-1 Zone______________________________________________________________________________ 175
Delay-2 Zone______________________________________________________________________________ 175
Reserved _________________________________________________________________________________ 175
Reserved _________________________________________________________________________________ 176
24 Hour Medical ___________________________________________________________________________ 176
24 Hour Panic _____________________________________________________________________________ 176
24 Hour Hold-Up __________________________________________________________________________ 176
24 Hour Tamper ___________________________________________________________________________ 176
Reserved _________________________________________________________________________________ 176
Keyswitch Zone ___________________________________________________________________________ 176
24 Hour Burglary Zone ______________________________________________________________________ 176
24 Hour Fire Zone __________________________________________________________________________ 176
Chime Zone_______________________________________________________________________________ 177
Zone Not Used ____________________________________________________________________________ 177
Zone Pulse Count ____________________________________________________________________________ 177
Zone Pulse Count Handover __________________________________________________________________ 177
Zone Pulse Count Time________________________________________________________________________ 178
Zone Options 1 ______________________________________________________________________________ 179
Lockout Siren & Lockout Dialler ______________________________________________________________ 179
Delay Alarm Reporting______________________________________________________________________ 179
Silent Alarm ______________________________________________________________________________ 180
Sensor Watch _____________________________________________________________________________ 180
Keyswitch Zone Options ______________________________________________________________________ 181
Latching Arm and Disarm In AWAY Mode _____________________________________________________ 181
Latching Arm In AWAY Mode _______________________________________________________________ 181
Latching Disarm From AWAY Mode, STAY Mode 1 Or STAY Mode 2_______________________________ 181
Latching Arm and Disarm In STAY Mode 1 _____________________________________________________ 181
Latching Arm In STAY Mode 1_______________________________________________________________ 181
Latching Disarm From STAY Mode 1 Or STAY Mode 2 ___________________________________________ 181
Momentary Arm and Disarm In AWAY Mode ___________________________________________________ 182
Momentary Arm In AWAY Mode _____________________________________________________________ 182
Momentary Disarm From AWAY Mode, STAY Mode 1 Or STAY Mode 2 ____________________________ 182
Momentary Arm and Disarm In STAY Mode 1 ___________________________________________________ 182
Momentary Arm In STAY Mode 1 ____________________________________________________________ 182
Momentary Disarm From STAY Mode 1 Or STAY Mode 2 _________________________________________ 182
Zone Options 2 ______________________________________________________________________________ 183
Isolate In STAY Mode 1_____________________________________________________________________ 183
Zone Isolation Allowed _____________________________________________________________________ 183
Forced Arming Allowed _____________________________________________________________________ 183
Zone Restore Report ________________________________________________________________________ 183
Zone Reporting Information ____________________________________________________________________ 184
Zone Report Code__________________________________________________________________________ 184
Zone Dialler Options _______________________________________________________________________ 184
Swinger Shutdown Count For Siren ______________________________________________________________ 185
Swinger Shutdown Count For Dialler ____________________________________________________________ 186
System Reporting Information _____________________________________________________ 187
Reporting Information_________________________________________________________________ 188
Zone Status – Bypass Reports __________________________________________________________________ 188
Zone Status – Trouble Reports __________________________________________________________________ 189
Zone Status – Sensor Watch Reports _____________________________________________________________ 190
Zone Status – Alarm Restore Code_______________________________________________________________ 190
Zone Status Reporting Options__________________________________________________________________ 190
Open/Close Reports __________________________________________________________________________ 191
Open/Close Reporting Options__________________________________________________________________ 191
Codepad Duress Report _______________________________________________________________________ 192
Codepad Panic Report ________________________________________________________________________ 192
Codepad Fire Report__________________________________________________________________________ 193
Codepad Medical Report ______________________________________________________________________ 193
Codepad Reporting Options ____________________________________________________________________ 194
System Status – Fuse Fail Report ________________________________________________________________ 194
System Status – Fuse Fail Restore Report _________________________________________________________ 194
System Status – AC Fail Report _________________________________________________________________ 195
System Status – AC Fail Restore Report __________________________________________________________ 195
System Status - Low Battery Report______________________________________________________________ 196
System Status - Low Battery Restore Report _______________________________________________________ 196
System Status - Access Denied__________________________________________________________________ 197
Code Retries ______________________________________________________________________________ 197
System Status Reporting Options ________________________________________________________________ 198
Test Reporting Time __________________________________________________________________________ 199
Test Reporting Dialler Options__________________________________________________________________ 199
Programmable Outputs ___________________________________________________________ 201
Outputs _____________________________________________________________________________ 202
Output Defaults______________________________________________________________________________ 202
Default For Strobe ___________________________________________________________________________ 202
Default For Entry/Exit ________________________________________________________________________ 202
Redirecting Outputs To The Codepad Buzzer ______________________________________________________ 203
Output Event Types __________________________________________________________________________ 204
Output Polarity ______________________________________________________________________________ 213
Output Not Used ___________________________________________________________________________ 213
Normally Open, Going Low __________________________________________________________________ 213
Normally Open, Pulsing Low _________________________________________________________________ 213
Normally Open, One Shot Low________________________________________________________________ 213
Normally Open, One Shot Low With Retrigger ___________________________________________________ 213
Normally Open, One Shot Low With Reset ______________________________________________________ 213
Normally Open, One Shot Low With Alarm______________________________________________________ 214
Normally Open, Latching Low ________________________________________________________________ 214
Normally Low, Going Open __________________________________________________________________ 214
Normally Low, Pulsing Open _________________________________________________________________ 214
Normally Low, One Shot Open________________________________________________________________ 214
Normally Low, One Shot Open With Retrigger ___________________________________________________ 214
Normally Low, One Shot Open With Reset ______________________________________________________ 214
Normally Low, One Shot Open With Alarm______________________________________________________ 214
Normally Low, Latching Open ________________________________________________________________ 214
Timing Of Outputs ___________________________________________________________________________ 215
Pulsing Polarities_____________________________________________________________________________ 215
One Shot Polarities ___________________________________________________________________________ 216
System Event Timers _____________________________________________________________ 217
System Event Timers _________________________________________________________________ 218
Programming Entry/Exit Timers _________________________________________________________________ 218
Entry Timer 1 _______________________________________________________________________________ 218
Entry Timer 2 _______________________________________________________________________________ 218
Exit Time __________________________________________________________________________________ 219
Entry Guard Timer For STAY Mode _____________________________________________________________ 219
Delay Alarm Reporting Time ___________________________________________________________________ 219
Sensor Watch Time ___________________________________________________________________________ 220
Codepad Lockout Time________________________________________________________________________ 220
Siren Run Time ______________________________________________________________________________ 221
Siren Sound Rate_____________________________________________________________________________ 221
Auto Arming Pre-Alert Timer___________________________________________________________________ 222
Auto Arming Time ___________________________________________________________________________ 222
Auto Disarming Time _________________________________________________________________________ 223
Kiss-Off Wait Time __________________________________________________________________________ 223
Reserved ___________________________________________________________________________________ 223
System Time ________________________________________________________________________________ 225
System Date ________________________________________________________________________________ 226
Setting The Date and Time ___________________________________________________________________ 226
System and Consumer Options _____________________________________________________ 227
Programming Option Bits _____________________________________________________________ 228
System Options 1 ____________________________________________________________________________ 229
EDM Smart Lockout Allowed ________________________________________________________________ 229
Horn Speaker Monitor ______________________________________________________________________ 229
Strobe Indications For Radio Arm/Disarm _______________________________________________________ 229
Horn Speaker Beeps For Radio Arm/Disarm _____________________________________________________ 229
System Options 2 ____________________________________________________________________________ 230
Codepad Panic To Be Silent __________________________________________________________________ 230
Codepad Fire To Be Silent ___________________________________________________________________ 230 odepad Medical To Be Silent _________________________________________________________________ 230
Access Denied To Be Silent __________________________________________________________________ 230
System Options 3 ____________________________________________________________________________ 231
AC Fail In 1 Hour (Disabled = After 2 Minutes) __________________________________________________ 231
Ignore AC Fail ____________________________________________________________________________ 231
Zone Pulse Count Handover __________________________________________________________________ 231
Handover Delay To Be Sequential _____________________________________________________________ 231
System Options 4 ____________________________________________________________________________ 232
Panel To Power Up Disarmed (If Power Reset)___________________________________________________ 232
Arm/Disarm Tracking On Power Up ___________________________________________________________ 232
Internal Crystal To Keep Time ________________________________________________________________ 232
Keyswitch Interface, Night Arm Station Or RE005 Installed _________________________________________ 232
Consumer Options 1 __________________________________________________________________________ 233
Test Reports When Armed ___________________________________________________________________ 233
Test Report After Siren Reset _________________________________________________________________ 233
Auto Arm In STAY Mode 1 __________________________________________________________________ 233
STAY Indicator To Display Day Alarm Status ___________________________________________________ 233
Consumer Options 2 __________________________________________________________________________ 234
Codepad Display Extinguish After 60 Seconds ___________________________________________________ 234
Single Button Arming Allowed (AWAY/STAY Mode 1 & 2) _______________________________________ 234
Single Button Disarming Allowed (STAY Mode 1 & 2) ____________________________________________ 234
Alarm Memory Reset On Disarm ______________________________________________________________ 234
Consumer Options 3 __________________________________________________________________________ 235
Codepad Fault Alarm Beeps Allowed __________________________________________________________ 235
Use Digit 3 For Codepad Duress Instead Of Digit 9 _______________________________________________ 235
Alarm Activates Sirens & Strobe In STAY Mode 1 & 2 ____________________________________________ 235
Reserved _________________________________________________________________________________ 235
Radio Input Options __________________________________________________________________________ 236
Radio Receiver (WE800) ____________________________________________________________________ 236
Latching Keyswitch Input____________________________________________________________________ 236
Momentary Keyswitch Input _________________________________________________________________ 236
Partitioning_____________________________________________________________________ 237
CP5 Master Partitioned LED Codepad ___________________________________________________ 238
Zone Indicators ______________________________________________________________________________ 238
Area On/Off Indicators ________________________________________________________________________ 239
Area Display Indicators _______________________________________________________________________ 239
Status Indicators _____________________________________________________________________________ 239
PARTIAL Indicator ________________________________________________________________________ 239
AUX Indicator ____________________________________________________________________________ 240
MAINS Indicator __________________________________________________________________________ 240
FAULT Indicator __________________________________________________________________________ 240
Audible Indicators _________________________________________________________________________ 241
Operating Codepads In Partitioning _____________________________________________________ 242
Operating From A CP5 Area Addressable LED Codepad ___________________________________________ 242
Operating From A CP5 Master Partitioned Codepad _______________________________________________ 242
Programming ________________________________________________________________________ 243
Partitioning Options 1_________________________________________________________________________ 243
First To Open/Last To Close Reporting _________________________________________________________ 243
Area 1 Codepad Connected To Data Terminal ____________________________________________________ 243
Reset Sirens From Any Area Allowed __________________________________________________________ 244
Master Codepad To Display AUX Indicator When On-Line _________________________________________ 244
Partitioning Options 2_________________________________________________________________________ 244
Lock Area 1 To Receiver 1 and Lock Area 2 To Receiver 2 _________________________________________ 244
User Codes Can Arm/Disarm Both Areas At Same Time (Code + 0 + #) _______________________________ 244
Reserved _________________________________________________________________________________ 244
Reserved _________________________________________________________________________________ 244
Zone Allocations ______________________________________________________________________ 245
Zone Allocations For Area 1 ___________________________________________________________________ 245
Zone Allocations For Area 2 ___________________________________________________________________ 245
User Code Allocations _________________________________________________________________ 247
Setting Up and Programming Codepads For Partitioning____________________________________ 248
Setting Up The Master Partitioned Codepad As The Main Codepad. __________________________________ 248
Setting Up An Area 1 Codepad As The Main Codepad _____________________________________________ 248
Setting Up An Area 1 Codepad _______________________________________________________________ 248
Setting Up An Area 2 Codepad _______________________________________________________________ 248
Codepad Connections For Partitioning ___________________________________________________ 249
Optional Equipment ______________________________________________________________ 251
Optional Equipment___________________________________________________________________ 252
Terminals and Descriptions _______________________________________________________ 257
Terminal Definitions and Descriptions ___________________________________________________ 258
Glossary Of Terms ___________________________________________________________________ 259
Solution 844/862/880 Wiring Diagram ___________________________________________________ 262
Solution 844/862/880 Component Overlay ________________________________________________ 263
Telecom Connection Diagrams _________________________________________________________ 264
Appendices _____________________________________________________________________ 265
Appendix A _________________________________________________________________________ 266
Telephone Anti-Jamming ______________________________________________________________________ 266
Appendix B _________________________________________________________________________ 267
Test Reports Only When Armed _________________________________________________________________ 267
Specifications___________________________________________________________________ 269
Warranty Statement __________________________________________________________________ 270
Year 2000 Compliance ________________________________________________________________ 270
Specifications ________________________________________________________________________ 271
Software Version Number______________________________________________________________________ 271
Advice To Users _____________________________________________________________________________ 271
New Zealand Telepermit Notes__________________________________________________________________ 272
Solution 844 Programming Sheets __________________________________________________ 273
Solution 862 Programming Sheets __________________________________________________ 283
Solution 880 Programming Sheets __________________________________________________ 293
Index _________________________________________________________________________ 303
•
/'%<":$9%&"'((((
/'%<":$9%&"'(
Solution 844/862/880
Installation Manual
Congratulations on selecting the
Solution 844/862/880
control panel for your installation. So that you can obtain the most from your unit, we suggest that you take the time to read through this manual and familiarise yourself with the numerous outstanding operating and installation features of this system.
You will notice that in all aspects of planning, engineering, styling, operation, convenience and adaptability, we have sought to anticipate your every possible requirement. Programming simplicity and speed have been some of the major considerations and we believe that our objectives in this area have been more than satisfied.
This installation manual will explain all aspects of programming the
Solution
844/862/880
control panel from factory default to final commissioning. All system parameters and options are detailed, however, suitability is left up to the individual. Every control panel can be tailored to meet all requirements quickly and easily. The programming simplicity will make your installation quick, accurate and rewarding each and every time.
The
Solution
range of control panels are very popular amongst thousands of people throughout many countries of the world, all who have various levels of technical aptitude and ability. We have tried to aim this installation manual to all levels of readers.
As the
Solution
control panels continue to be improved over the years, they have become very powerful. Some of its early first-time users have advanced to true "power users" and we need to address their needs too, while maintaining the simplicity of the manual and the product.
ISSUE140 Electronics Design and Manufacturing Pty Limited
Introduction 19
!"#$%&"'()**(@71%$<70(
The
Solution 844
security system uses the very latest in microprocessor technology to provide you with more useful features and superior reliability and performance.
Following is a list of the main features that the control panel will provide.
!" Eight Programmable User Codes (1 – 8)
!" Eight Remote Radio User Codes (9 – 16)
!" Four Programmable Burglary Zones
!" Four 24 Hour Programmable Zones
!" Dual Reporting
!" On-Board Line Fault Module
!" Telco Arming/Disarming Sequence
!" Automatic Arming
!" Automatic Disarming
!" Codepad Duress, Panic, Fire, Medical Alarms
!" STAY Mode and AWAY Mode Operation
!" Upload/Download Programmable
!" Dynamic Battery Testing
!" Entry and Exit Warning Beeper
!" Remote Arming
!" Answering Machine Bypass
!" AC Fail and System Fault Indicators
!" Monitored Siren Output
!" Strobe Output
!" Relay Output
!" Separate Fire Alarm Sound
!" EDMSAT – Satellite Siren Compatible
!" Zone Lockout
!" Sensor Watch
!" Day Alarm
!" Event Memory Recall
!" Walk Test Mode
!" Delayed Reporting
Electronics Design and Manufacturing Pty Limited ISSUE140
Solution 844/862/880
Installation Manual
!"#$%&"'(),-(@71%$<70(
The
Solution 862
security system uses the very latest in microprocessor technology to provide you with more useful features and superior reliability and performance.
Following is a list of the main features that the control panel will provide.
!" Eight Programmable User Codes (1 – 8)
!" Eight Remote Radio User Codes (9 – 16)
!" Six Programmable Burglary Zones
!" Two 24 Hour Programmable Zones
!" Dual Reporting
!" On-Board Line Fault Module
!" Telco Arming/Disarming Sequence
!" Automatic Arming
!" Automatic Disarming
!" Codepad Duress, Panic, Fire, Medical Alarms
!" STAY Mode and AWAY Mode Operation
!" Upload/Download Programmable
!" Dynamic Battery Testing
!" Entry and Exit Warning Beeper
!" Remote Arming
!" Answering Machine Bypass
!" AC Fail and System Fault Indicators
!" Monitored Siren Output
!" Strobe Output
!" Relay Output
!" Separate Fire Alarm Sound
!" EDMSAT – Satellite Siren Compatible
!" Zone Lockout
!" Sensor Watch
!" Day Alarm
!" Event Memory Recall
!" Walk Test Mode
!" Delayed Reporting
ISSUE140 Electronics Design and Manufacturing Pty Limited
Introduction 21
!"#$%&"'()).(@71%$<70(
The
Solution 880
security system uses the very latest in microprocessor technology to provide you with more useful features and superior reliability and performance.
Following is a list of the main features that the control panel will provide.
!" Eight Programmable User Codes (1 – 8)
!" Eight Variable User Codes (Radio Remote/Programmable User Codes (9 - 16))
!" Eight Programmable Burglary Zones
!" Partitionable To Two Separate Areas
!" Dual Reporting
!" On-Board Line Fault Module
!" Telco Arming/Disarming Sequence
!" Automatic Arming
!" Automatic Disarming
!" Codepad Duress, Panic, Fire, Medical Alarms
!" STAY Mode and AWAY Mode Operation
!" Upload/Download Programmable
!" Dynamic Battery Testing
!" Entry and Exit Warning Beeper
!" Remote Arming
!" Answering Machine Bypass
!" AC Fail and System Fault Indicators
!" Monitored Siren Output
!" Strobe Output
!" Relay Output
!" Separate Fire Alarm Sound
!" EDMSAT – Satellite Siren Compatible
!" Zone Lockout
!" Sensor Watch
!" Day Alarm
!" Event Memory Recall
!" Walk Test Mode
!" Delayed Reporting
Electronics Design and Manufacturing Pty Limited ISSUE140
A$&9B(!%1<%(
Solution 844/862/880
Installation Manual
The following steps will allow you to use the
Solution 844/862/880
control panel with the factory default values. The default values allow the control panel to communicate in the
Contact ID format. If you are not familiar to programming the
Solution
range of control panels, we suggest that you first read information contained in the programming section beginning on page 28.
1.
After all wiring has been completed; connect the AC plug pack to the control panel.
Both the
MAINS
and
AWAY
indicators will illuminate. The
MAINS
indicator will display to indicate that the AC mains supply has been connected. The AWAY indicator displays that the system is now armed in the AWAY Mode. If any 24 hour zones are unsealed at the time the system is powered up, the siren, strobe and bell outputs will activate into alarm and the corresponding zone indicator will flash.
2.
Enter the default Master Code
2580
followed by the button to disarm the system and to reset any alarm that may have occurred during the system power up. The
AWAY
indicator will extinguish to indicate that the system has now been disarmed. If any zone indicators were flashing, this would indicate that an alarm had occurred on that zone. If a zone indicator is constantly illuminated, this would indicate that the zone is unsealed.
3.
4.
The back-up battery should now be connected.
Enter the factory default Installer Code
1234
followed by the button. Two beeps will be heard and the
STAY
and
AWAY
indicators will now flash simultaneously to indicate that you have now entered Installer’s Programming Mode. When entering
Installer’s Programming Mode, you will be automatically positioned at “LOCATION
000”, the beginning of the Primary Telephone Number For Receiver 1.
5.
Enter the Primary Telephone Number followed by the Secondary Telephone Number and the Subscriber ID Number for Receiver 1. Refer to Dialler Information on page
142 for more information.
6.
7.
8.
Remember that when programming a zero in the telephone numbers of Receiver 1 and
Receiver 2, a zero must be programmed as a ten. Programming a zero in the telephone number will indicate the end of the dialling sequence. A zero must be programmed as a zero in all other locations other than the telephone numbers for Receiver 1, Receiver 2 and the Call Back Telephone number, unless otherwise stated.
Set the time for the test reports if required. Any other programming changes required may also be made; otherwise the factory default settings will be used. Refer to Test
Reporting Time on page 199 for more information on programming test reports.
Enter Installer’s Command
960
followed by the button to exit Installer’s
Programming Mode. Two beeps will be heard and the
STAY
and
AWAY
indicators will extinguish. The system has now returned to the disarmed state and is now ready for use.
Refer to Installer’s Programming Commands on page 35 for more information.
Use the Master Code to set the date and time. Refer to How To Set The New Date and
Time on page 23 for more information.
ISSUE140 Electronics Design and Manufacturing Pty Limited
Introduction 23
C"D(3"(!7%(347(E7D(F1%7(1':(3&G7(
1.
2.
Enter your followed by
6
and the button.
Three beeps will be heard and the STAY and AWAY indicators will begin to flash.
Enter the day, month, year, hour and minute using the (DD, MM, YY, HH, MM) format
(i.e. DD = Day of the month, MM = Month of the year, YY = Current year, HH = Hour of the day, MM = Minute of the day).
Please note that when programming the hour of the day, you will need to use 24:00 hour format.
3.
Press the button when finished.
Two beeps will be heard and the STAY and AWAY indicators will extinguish. If a long beep is heard, an error was made when entering the date and time.
+
6
+
+
DD
+
MM
+
YY
+
HH
+
MM
+
HI1G5#7(
If the date and time needs to be set for the 1st January 1997 at 10:30 PM, program the date and time as follows;
2580
+
6
+
+
0
+
1
+
0
+
1
+
9
+
7
+
2
+
2
+
3
+
0
+
Electronics Design and Manufacturing Pty Limited ISSUE140
Solution 844/862/880
Installation Manual
!"#$%&"'()**(J"'7(F7;1$#%0
The default zone settings of the control panel are listed in the table below. Zones 1 – 4 may be programmed to any of the available zone types. Zones 5 – 8 are limited to that they may only be programmed to any 24 hour or keyswitch type. Refer to “Table 4: Available Zone Types” on page 25 for the different zone types that may be selected.
J"'7(E"(
1
2
3
4
Delay-1
Handover
Handover
Instant
J"'7(3=57( J"'7(E"(
5
6
7
8
J"'7(3=57(
24 Hour Burglary
24 Hour Burglary
24 Hour Fire
24 Hour Tamper
Table 1: Zone Defaults For Solution 844
!"#$%&"'(),-(J"'7(F7;1$#%0
The default zone settings of the control panel are listed in the table below. Zones 1 – 6 may be programmed to any of the available zone types. Zones 7 and 8 are limited to that they may only be programmed to any 24 hour or keyswitch type. Refer to “Table 4: Available Zone
Types” on page 25 for the different zone types that may be selected.
J"'7(E"(
1
2
3
4
Delay-1
Handover
J"'7(3=57(
Handover
Handover
J"'7(E"(
5
6
7
8
J"'7(3=57(
Instant
Instant
24 Hour Fire
24 Hour Tamper
Table 2: Zone Defaults For Solution 862
!"#$%&"'()).(J"'7(F7;1$#%0
The default zone settings of the control panel are listed in the table below. Zones 1 – 8 may be programmed to any of the available zone types. Refer to “Table 4: Available Zone Types” on page 25 for the different zone types that may be selected.
J"'7(E"(
1
2
3
4
Delay-1
Handover
Handover
Handover
J"'7(3=57( J"'7(E"(
5
6
7
8
Table 3: Zone Defaults For Solution 880
J"'7(3=57(
Instant
Instant
Instant
24 Hour Tamper
ISSUE140 Electronics Design and Manufacturing Pty Limited
Introduction 25
J"'7(3=570(
There are thirteen different zone types to choose from when programming zones. These thirteen different zone types are available for all
Solution 844/862/880
control panels.
Refer to Zone Programming on page 173 for more information on programming zones.
J"'7(3=57( F709<&5%&"'( J"'7(3=57( F709<&5%&"'(
0
1
Instant
Handover
8
9
24 Hour Hold-Up
24 Hour Tamper
2
3
4
5
6
7
Delay-1
Delay-2
Reserved
Reserved
24 Hour Medical
24 Hour Panic
10
11
12
13
14
15
Reserved
Keyswitch
24 Hour Burglary
24 Hour Fire
Chime Only
Zone Not Used
Table 4: Available Zone Types
Electronics Design and Manufacturing Pty Limited ISSUE140
Solution 844/862/880
Installation Manual
ISSUE140 Electronics Design and Manufacturing Pty Limited
(
K<"6<1GG&'6(
Solution 844/862/880
Installation Manual
K<"6<1GG&'6(
HI1G5#7(
(
LOCATION 000 - 015
The programming options of the control panel are stored in a non-volatile EPROM. This memory will hold all the relevant configuration and user specific data even during a total power loss.
The data retention time is as long as ten years without power; therefore, no reprogramming will be required after powering the control panel down.
The data can be changed as many times as required without the need for any additional specialised equipment. This memory is laid out in numerous locations, each of which holds the data for a specific function.
15 is the maximum value that can be programmed into any location.
In general, the entire programming sequence will consist of nominating the required location number and then enter or change the current data. You will repeat this procedure until all the data has been programmed to suit your requirements. The factory default settings have been selected for reporting to the monitoring station in the Contact ID Format.
The Installers Code only gives access to the Installer's Programming Mode and does NOT arm and disarm the system. Installer’s Programming Mode can not be entered when the system is armed, or at any time during siren run time.
Programming of the
Solution 844/862/880
control panel can be carried out via any of the following three methods.
•
Remote Codepad
•
Hand Held Programmer (CC814)
•
Alarm Link Upload/Download Software (CC816)
K<&G1<=(37#754"'7(E$G87<(@"<(L797&M7<(N (
0000000000000000
ISSUE140 Electronics Design and Manufacturing Pty Limited
Programming 29
K<"6<1GG&'6(O&%4(347(L7G"%7(?":751:(
When programming the control panel via the remote codepad, the system must be in the disarmed state with no alarm memory present.
To access the Installer’s Programming Mode, enter the four digit the
followed by
button. The factory default Installer Code is
1234
. Two beeps will be heard and both the AWAY and the STAY indicators will flash simultaneously to indicate that you have entered Installer’s Programming Mode.
When entering Installer’s Programming Mode, you will be automatically positioned at
“LOCATION 000”, the beginning of the Primary Telephone Number for Receiver 1.
F1%1(
P1#$7(
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
J"'7(N(
/':&91%"<(
#"
J"'7(-(
/':&91%"<(
J"'7(Q(
/':&91%"<(
J"'7(*(
/':&91%"<(
#"
#"
#"
J"'7(R(
/':&91%"<(
J"'7(,(
/':&91%"<(
J"'7(S(
/':&91%"<(
J"'7()(
/':&91%"<(
2T/E!(
/':&91%"<(
#"
#"
#"
#"
#"
#"
#"
#"
#"
#"
#"
#"
#"
#"
#"
#"
#"
Table 5: Codepad Indicators When Programming
HI1G5#7(
To access Installer’s Programming Mode, enter the followed by the button. Two beeps will be heard and both the
AWAY
and the
STAY indicators will flash simultaneously to indicate that you have entered Installer’s Programming Mode. The codepad indicators will display the current data stored in the first location (LOCATION 000). by the
34
followed by the button will automatically step you to the beginning of the Subscriber ID Number for Receiver 1).
To move to the next location, press the button. This will step you to the next location and the data in that location will be displayed (e.g. If you are currently positioned at
“LOCATION 034”, pressing the button will step you to “LOCATION 035”).
If you press the button without previously entering a location number, the system will step back one location (e.g. If you are positioned at “LOCATION 035” and you press the
button, you will step back one location to LOCATION 034).
Electronics Design and Manufacturing Pty Limited ISSUE140
Solution 844/862/880
Installation Manual
To change data in the current location, enter the new value (0 – 15) followed by the button. This will store the new data into the location and still leave you positioned at the same location. You will notice that the new information programmed will be displayed on the codepad indicators (e.g. If you enter the value
14
followed by the button, both
ZONE
4 and the
MAINS
indicator will illuminate).
To move to the next location, press the now be displayed.
button. The data in the next locations data will
To exit the Installer’s Programming Mode, enter command
960
followed by the button. Two beeps will be heard and the
STAY
and
AWAY
indicators will extinguish. The system will now return to the disarmed state and is now ready for use.
Refer to Installer’s Programming Commands on page 35 for further information on commands that can be performed during access of Installer’s Programming Mode.
ISSUE140 Electronics Design and Manufacturing Pty Limited
Programming 31
K<"6<1GG&'6(O&%4(347(C1':(C7#:(K<"6<1GG7<(
The Hand Held Programmer (CC814) has five, seven segment displays. The three seven segment displays on the left display the current location number and the two seven segment displays on the right display the data for the location currently being displayed.
To connect the hand held programmer, locate the socket marked PROGRAMMING KEY found at the top of the PCB (printed circuit board) next to the Auxiliary Module socket.
Observe the triangular markings on the PCB and line them up with the markings on the hand held programmers connecting socket.
When the hand held programmer is correctly connected onto the printed circuit board, one beep will be heard and four centre bars on the hand held programmer will illuminate with either an 'A' or 'U' suffix to indicate the system is armed or unarmed. Only when the
Installer's Programming Mode has been accessed will any numerals appear on the display.
When connecting the hand held programmer to the control panel, make sure that the switch on the hand held programmer is in the EXT position and that no external programming key has been connected. Failing to do this may corrupt the control panel's
memory. If this occurs, the control panel will need to be returned to Electronics Design
and Manufacturing Pty Limited where a service fee will be charged to unlock the control panel's memory.
HI1G5#7(
To access the Installer's Programming Mode, enter the followed by the
# button. The factory default Installers Code is
1234
. Two beeps will be heard and the hand held programmer will display the current data stored in "LOCATION 000".
To move to another programming location, enter the required followed by the
#
button. The data of the new location will now be displayed (e.g.
34
followed by the
#
button will automatically step you to the beginning of the Subscriber ID Number for
Receiver 1).
To move to the next location, press the
#
button. This will step you to the next location and the data in that location will be displayed (e.g. If you are currently positioned at “LOCATION
034”, pressing the
#
button will step you to “LOCATION 035”).
If you press the button without previously entering a location number, the system will step back one location (e.g. If you are positioned at “LOCATION 035” and you press the
* button, you will step back one location to LOCATION 034).
To change data in the current location, enter the new value (0 – 15) followed by the
*
button.
This will store the new data into the location and still leave you positioned at the same location. You will notice that the new information programmed will be displayed on the data display of the hand held programmer (e.g. If you enter the value
14
followed by the
* button, the data display will display 14).
To move to the next location, press the
#
button. The data in the next location will now be displayed.
Electronics Design and Manufacturing Pty Limited ISSUE140
Solution 844/862/880
Installation Manual
To exit the Installer's Programming Mode, enter command
960
followed by the
# button. Two beeps will be heard and the system will return to the disarmed state. Refer to
Installer’s Programming Commands on page 35 for further information on commands that can be performed during access of the Installer's Programming Mode.
When using the hand held programmer, any reference in this manual made to the button should be considered as the
*
button and the button considered as the
#
button.
ISSUE140 Electronics Design and Manufacturing Pty Limited
Programming 33
K<"6<1GG&'6(O&%4(347(K<"6<1GG&'6(U7=(
The Programming Key (CC891) is a unique device that will allow you to store or copy programming information from your control panel. Once the programming key has information stored in the microprocessor, the programming key may be used to easily program other existing
Solution 844/862/880
control panels with the same programming data, or be alternatively used for back up purposes of existing information.
Connecting a programming key, which has been pre-programmed directly onto the control panel in the disarmed state, will automatically initiate a data transfer from the programming key to the control panel memory.
If you have a new programming key, you should first enter the Installer's Programming Mode and program the system as required before connecting the programming key to the control panel.
To connect the programming key, locate the socket marked PROGRAMMING KEY found at the top of the PCB (printed circuit board) next to the Auxiliary Module socket. Observe the triangular markings on the printed circuit board and line them up with the markings on the programming key.
To copy the control panel's data into the programming key, access Installer’s Programming
Mode (e.g.:
1234
followed by the
#
button) and enter Installer’s Programming
Command
962
followed by the
#
button. Refer to Command 962 - Copy Control Panel
Memory To Programming Key on page 40 for further information.
To exit the Installer's Programming Mode, enter command
960
followed by the
# button. Two beeps will be heard and the system will return to the disarmed state. Before removing the programming key, wait two seconds for the activity LED to return to its normal state. The programming key will now become your standard data pattern for future programming of your control panels.
It should be noted that when entering the Installer's Programming Mode, inserting a programming key and then changing any location will cause a simultaneous update of not only the programming keys data, but also the control panels data. Therefore, you are not able to change data in the programming key without the same location being changed in the control panels memory.
Connecting a Programming Key (CC891) to the control panel when the programming keys memory is blank will corrupt the control panel's memory unless the Installer's
Programming Mode has been entered first. If this occurs, then the control panel will need to be returned to Electronics Design and Manufacturing Pty Limited where a service fee will be charged to unlock the control panel's memory.
Electronics Design and Manufacturing Pty Limited ISSUE140
Solution 844/862/880
Installation Manual
K<"6<1GG&'6(>5%&"'(V&%0(
When programming these locations, you will notice that there are four alternatives per location.
You may select one, two, three or all of these alternatives for each location, however, only one number is required to be programmed. This number is calculated by adding the option bit numbers together.
HI1G5#7(
If at "LOCATION 177" you want options 1, 2 and 4, add the numbers together and the total is the number to be programmed. In this example, the number to be programmed is 7 (i.e. 1 + 2
+ 4 = 7).
>5%&"'(
1
F709<&5%&"'(
Enabled = Allow Dialler Reporting Functions
Disabled = Disable All Dialler Reporting Functions
2
Enable Remote Arming Via The Telephone
4
8
Enable Answering Machine Bypass Only When Armed
Enabled = Use Bell 103 For FSK Format
Disabled = CCITT V21 Format
Table 6: Example - Programming Option Bits
ISSUE140 Electronics Design and Manufacturing Pty Limited
Programming 35
/'0%1##7<W0(K<"6<1GG&'6(?"GG1':0(
There are ten different commands that can be used to perform various functions once the
Installer's Programming Mode has been entered. To issue the command required, enter the corresponding numerical code followed by the
#
button.
?"GG1':( F709<&5%&"'( K167(
958
Enable/Disable Zone Status Mode 36
959
Test Programming Key
Exit Installer’s Programming Mode
37
39
960
961
962
Reset Control Panel Back To Factory Default Settings
Copy The Control Panel Memory To The Programming Key
Copy The Programming Key Data To The Control Panel
963
964
39
40
41
965
966
999
Erase Programming Key
Set Up Domestic Dialling Format
Enable/Disable Automatic Stepping Of Locations During Programming
This Command Displays The Control Panel’s Software Version Number Or
Control Panel Type
Table 7: Installer's Programming Commands
42
43
44
46
Electronics Design and Manufacturing Pty Limited ISSUE140
Solution 844/862/880
Installation Manual
?"GG1':(XR)(Y(H'18#7+F&018#7(J"'7(!%1%$0(2":7(
This function enables and disables the zone status display mode when using the hand held programmer. The hand held programmer will display the zones on the seven-segment display from left to right. If there is a dash illuminated on the display of the hand held programmer, the corresponding zone is unsealed and if the display is blank, the zone is sealed.
The third (or centre) display shows either the number 4 or the number 8. The number 4 constantly illuminated indicates that zones 1 - 4 are being displayed. The number 8 constantly illuminated indicates that zones 5 - 8 are being displayed.
Pressing the
#
button will toggle the display between the zones. This feature will prove to be very useful during installation as the hand held programmer allows you to view the status of the zones directly at the control panel, saving you time and money.
C"D(3"(H'18#7(J"'7(!%1%$0(2":7(
1.
Enter Installers Programming Mode (i.e.
1234
followed by the
#
button).
Two beeps will be heard and the hand held programmer will display the data currently programmed in “LOCATION 000”.
2.
Enter command
958
followed by the
#
button.
Two beeps will be heard and the number 4 will illuminate to indicate zones 1 – 4 are being displayed.
C"D(3"(F&018#7(J"'7(!%1%$0(2":7(
1.
Enter command
958
followed by the
#
button.
Two beeps will be heard and you will return to the Installer’s Programming Mode.
HI1G5#7(
A " - " in the display indicates the zone is unsealed.
A blank display indicates the zone is sealed.
À
indicates that zone 1 is sealed and zones 2, 3 and 4 are unsealed.
À-
indicates that zones 5 and 8 are unsealed and zones 6 and 7 are sealed.
ISSUE140 Electronics Design and Manufacturing Pty Limited
Programming 37
?"GG1':(XRX(Y(370%(K<"6<1GG&'6(U7=(
This command initiates a test to be carried out on the programming key. Only the
Programming Key (CC891) may be used with the
Solution 844/862/880
control panel.
The programming key test is non-destructive and any data in the programming key will remain intact after the test has been completed. One long beep indicates that the programming key test has failed and two beeps indicates a successful test.
If the programming key has been removed before the test is complete or the programming key has failed, the data in the programming key has become corrupt. Remember not to remove the programming key while the activity LED is constantly illuminated or pulsing rapidly.
C"D(3"(370%(347(K<"6<1GG&'6(U7=(
1.
Enter Installer's Programming Mode (i.e.
1234
followed by the
#
button).
Two beeps will be heard and the STAY and AWAY indicators will begin to flash on the remote codepad to indicate that you have entered Installer’s Programming Mode. You will also notice that the remote codepad will display the data currently programmed in
“LOCATION 000”.
2.
Plug the programming key onto the pins marked PROGRAMMING KEY on the control panel found at the top of the PCB (printed circuit board) next to the Auxiliary Module socket.
3.
4.
Enter command
959
followed by the
#
button.
Two beeps will be heard after the programming key has successfully been tested. If you heard a long beep after issuing this command, the programming key has become corrupt and will need to be erased to clear the corrupt data. Refer to Command 964 - Erase
Programming Key on page 42 for more information.
Before removing the programming key from the control panel, enter command
960
followed by the
#
button to exit the Installer's Programming Mode. Two beeps will be heard. The STAY and AWAY indicators will now extinguish on the remote codepad and the system will return to the disarmed state.
Failing to exit Installer’s Programming Mode before removing the programming key may result in corrupting the data in the programming key.
Electronics Design and Manufacturing Pty Limited ISSUE140
Solution 844/862/880
Installation Manual
C"D(3"(370%(347(K<"6<1GG&'6(U7=(Z0&'6(347(C1':(C7#:(K<"6<1GG7<(
1.
2.
3.
4.
5.
Before connecting the hand held programmer onto the pins marked PROGRAMMING
KEY, make sure that the switch on the hand held programmer is in the EXT position and that no external key has been plugged onto the hand held programmer.
Enter the Installer's Programming Mode (i.e.
1234
followed by the
#
button).
Two beeps will be heard and the hand held programmer will display the data currently programmed in “LOCATION 000”.
Plug the programming key onto the pins marked EXTERNAL KEY on the hand held programmer.
Enter command
959
followed by the
#
button.
Two beeps will be heard after the programming key has successfully been tested. If you heard a long beep after issuing this command, the programming key has become corrupt and will need to be erased to clear the corrupt data. Refer to Command 964 - Erase
Programming Key on page 42 for more information.
Before removing the programming key from the hand held programmer, enter command
960
followed by the
#
button to exit the Installer's Programming Mode. Two beeps will be heard and the system will now return to the disarmed state.
Failing to exit Installer’s Programming Mode before removing the programming key may result in corrupting the data in the programming key.
ISSUE140 Electronics Design and Manufacturing Pty Limited
Programming 39
?"GG1':(X,.(Y(HI&%(/'0%1##7<[0(K<"6<1GG&'6(2":7(
This command is used to exit the Installer's Programming Mode after you complete programming the control panel.
You may exit Installer’s Programming Mode from any location by entering command
960
followed by the
#
button. Two beeps will be heard and the system will return to the disarmed state. When using the remote codepad to program the system, you will notice that the STAY and AWAY indicators will extinguish to indicate that you have terminated Installer’s
Programming Mode.
?"GG1':(X,NY(L707%(?"'%<"#(K1'7#(V19B(3"(@19%"<=(F7;1$#%(
!7%%&'60(
This command will reset the control panel back to the factory default values. Refer to the default values shown throughout this manual or the programming sheets on pages 273 - 293 for more information.
You may reset the control panel back to the factory default settings from any location when in
Installer’s Programming Mode. This is achieved by entering command
961
followed by the
#
button. Two beeps will be heard and the system will default back to the factory default values.
Electronics Design and Manufacturing Pty Limited ISSUE140
ISSUE140
Solution 844/862/880
Installation Manual
?"GG1':(X,-(Y(?"5=(?"'%<"#(K1'7#(27G"<=(3"(K<"6<1GG&'6(U7=(
This command is used to copy the control panel memory to the programming key. Only the
Programming Key (CC891) may be used with the
Solution 844/862/880
control panel.
C"D(3"(?"5=(347(?"'%<"#(K1'7#(27G"<=(3"(347(K<"6<1GG&'6(U7=(
1.
2.
Enter Installer's Programming Mode (i.e.
1234
followed by the
#
button).
Two beeps will be heard and the
STAY
and
AWAY
indicators will begin to flash on the remote codepad to indicate that you have entered Installer’s Programming Mode. You will also notice that the remote codepad will display the data currently programmed in
“LOCATION 000”.
Plug the programming key onto the pins marked PROGRAMMING KEY on the control panel found at the top of the PCB (printed circuit board) next to the Auxiliary Module socket.
3.
4.
Enter command
962
followed by the
#
button.
Two beeps will be heard after the control panel memory has successfully been copied into the programming key. If you heard a long beep after issuing this command, the programming key has become corrupt and will need to be erased to clear the corrupt data. Refer to Command 964 - Erase Programming Key on page 42 for more information.
Before removing the programming key from the control panel, enter command
960
followed by the
#
button to exit Installer's Programming Mode. The STAY and AWAY indicators will now extinguish on the remote codepad to indicate that the system has returned to the disarmed state.
Failing to exit Installer’s Programming Mode before removing the programming key may result in corrupting the programming key.
C"D(3"(?"5=(347(K1'7#(27G"<=(3"(K<"6<1GG&'6(U7=(Z0&'6(347(C1':(C7#:(K<"6<1GG7<(
1.
2.
3.
4.
5.
Before connecting the hand held programmer onto the pins marked PROGRAMMING
KEY, make sure that the switch on the hand held programmer is in the EXT position and that no external key has been plugged onto the hand held programmer.
Enter Installer's Programming Mode (i.e.
1234
followed by the
#
button).
Two beeps will be heard and the hand held programmer will display the data currently programmed in “LOCATION 000”.
Plug the programming key onto the pins marked EXTERNAL KEY on the hand held programmer.
Enter command
962
followed by the
#
button.
Two beeps will be heard after the control panel memory has successfully been copied into the programming key. If you heard a long beep after issuing this command, the programming key has become corrupt and will need to be erased to clear the corrupt data. Refer to Command 964 - Erase Programming Key on page 42 for more information.
Before removing the programming key from the hand held programmer, enter command
960
followed by the
#
button to exit Installer's Programming Mode. Two beeps will be heard and the system will now return to the disarmed state.
Failing to exit Installer’s Programming Mode before removing the programming key may result in corrupting the programming key.
Electronics Design and Manufacturing Pty Limited
Programming 41
?"GG1':(X,Q(Y(?"5=(@<"G(K<"6<1GG&'6(U7=(3"(?"'%<"#(K1'7#(
This command is used to copy data from the programming key to the control panel. Only the
Programming Key (CC891) may be used with the
Solution 844/862/880
control panel.
C"D(3"(?"5=(347(K<"6<1GG&'6(U7=(27G"<=(3"(347(?"'%<"#(K1'7#(
1.
2.
Enter Installer's Programming Mode (i.e.
1234
followed by the
#
button).
Two beeps will be heard and the STAY and AWAY indicators will begin to flash on the remote codepad to indicate that you have entered Installer’s Programming Mode. You will also notice that the remote codepad will display the data currently programmed in
“LOCATION 000”.
Connect the programming key onto the pins marked PROGRAMMING KEY on the control panel found at the top of the PCB (printed circuit board) next to the Auxiliary
Module socket.
3.
4.
Enter command
963
followed by the
#
button.
Two beeps will be heard after the programming key's data has successfully been copied into to the control panel. If you heard a long beep after issuing this command, the programming key has become corrupt and will need to be erased to clear the corrupt data. Refer to Command 964 - Erase Programming Key on page 42 for more information.
Before removing the programming key from the control panel, enter command
960
followed by the
#
button to exit Installer's Programming Mode. The STAY and
AWAY
indicators will now extinguish on the remote codepad and the system will return to the disarmed state.
Failing to exit Installer’s Programming Mode before removing the programming key may result in corrupting the programming key.
C"D(3"(?"5=(K<"6<1GG&'6(U7=(27G"<=(3"(?"'%<"#(K1'7#(Z0&'6(C1':(C7#:(K<"6<1GG7<(
1.
2.
3.
4.
5.
Before connecting the hand held programmer onto the pins marked PROGRAMMING
KEY, make sure that the switch on the hand held programmer is in the EXT position and that no external key has been plugged onto the hand held programmer.
Enter Installer's Programming Mode (i.e.
1234
followed by the
#
button).
Two beeps will be heard and the hand held programmer will display the data currently programmed in “LOCATION 000”.
Plug the programming key onto the pins marked EXTERNAL KEY on the hand held programmer.
Enter command
963
followed by the
#
button.
Two beeps will be heard after the programming key's data has successfully been copied into to the control panel. If you heard a long beep after issuing this command, the programming key has become corrupt and will need to be erased to clear the corrupt data. Refer to Command 964 - Erase Programming Key on page 42 for more information.
Before removing the programming key from the hand held programmer, enter command
960
followed by the
#
button to exit Installer's Programming Mode. Two beeps will be heard and the system will now return to the disarmed state.
Failing to exit Installer’s Programming Mode before removing the programming key may result in corrupting the programming key.
Electronics Design and Manufacturing Pty Limited ISSUE140
ISSUE140
Solution 844/862/880
Installation Manual
?"GG1':(X,*(Y(H<107(K<"6<1GG&'6(U7=(
This command erases all data from the programming key. Only the Programming Key
(CC891) may be used with the
Solution 844/862/880
control panel.
C"D(3"(H<107(347(K<"6<1GG&'6(U7=(
1.
2.
Enter Installer's Programming Mode (i.e.
1234
followed by the
#
button).
Two beeps will be heard and the
STAY
and
AWAY
indicators will begin to flash on the remote codepad to indicate that you have entered Installer’s Programming Mode. You will also notice that the remote codepad will display the data currently programmed in
“LOCATION 000”.
Connect the programming key onto the pins marked PROGRAMMING KEY on the control panel found at the top of the PCB (printed circuit board) next to the Auxiliary
Module socket.
3.
4.
Enter command
964
followed by the
#
button.
Two beeps will be heard after the programming keys data has been deleted.
Before removing the programming key from the control panel, enter command
960
followed by the
#
button to exit Installer's Programming Mode. The STAY and AWAY indicators will now extinguish on the remote codepad and the system will return to the disarmed state.
Failing to exit Installer’s Programming Mode before removing the programming key may result in corrupting the programming key.
C"D(3"(H<107(347(K<"6<1GG&'6(U7=(Z0&'6(347(C1':(C7#:(K<"6<1GG7<(
1.
Before connecting the hand held programmer onto the pins marked PROGRAMMING
KEY, make sure that the switch on the hand held programmer is in the EXT position and that no external key has been plugged onto the hand held programmer.
2.
Enter Installer's Programming Mode (i.e.
1234
followed by the
#
button).
Two beeps will be heard and the hand held programmer will display the data currently programmed in “LOCATION 000”.
3.
4.
5.
Plug the programming key onto the pins marked EXTERNAL KEY on the hand held programmer.
Enter command
964
followed by the
#
button.
Two beeps will be heard after the programming keys data has been deleted.
Before removing the programming key from the hand held programmer, enter command
960
followed by the
#
button to exit Installer's Programming Mode. Two beeps will be heard and the system will now return to the disarmed state.
Failing to exit Installer’s Programming Mode before removing the programming key may result in corrupting the programming key.
Electronics Design and Manufacturing Pty Limited
Programming 43
?"GG1':(X,R(Y(!7%(Z5(F"G70%&9(F&1##&'6(@"<G1%(
Command 965 has been included to allow the set up of the domestic dialling format a one step operation. Refer to page 132 for more information on Domestic Dialling Format.
After you enter Installer's Programming Mode, enter command
965
followed by the
# button. The command will automatically set Receiver 1 to domestic reporting and set the following locations only for Receiver 2. No other locations will be changed when command
965 has been issued.
All domestic telephone numbers are stored in “LOCATION 466 – 513”. For more information on programming domestic dialling, refer to Setting Up and Programming Domestic Reporting on page 133 for more information.
\"91%&"'( F709<&5%&"'( !7%%&'6(
LOCATION 032
LOCATION 033
Handshake Tone For Receiver 1
Transmission Format
1 (Handshake Tone)
LOCATION 034 – 039 Subscriber ID Number
LOCATION 332 Zone Status Reporting Options
4 (Domestic)
0, 0, 0, 0, 0, 1 (1 Beep)
2 (Receiver 2 Only)
LOCATION 333 – 334 Open/Close Reports
LOCATION 335 Open/Close Reporting Options
LOCATION 356 - 358
LOCATION 359
LOCATION 360 - 366
LOCATION 367
System Status – Access Denied
System Status Reporting Options
Test Reporting Time
Test Reporting Dialler Options
11, 12 (Open/Close Reports)
2 (Receiver 2 Only)
6, 7, 12 (Access Denied)
2 (Receiver 2 Only)
0, 0, 0, 0, 7, 1, 0 (Test Reports)
1 (Receiver 1 Only)
Table 8: Command 965 Defaults
As you can see from the table above, the transmission format has automatically been set for domestic dialling and the Subscriber ID Number has been set for one identification beep. All reports except zone status reporting and system status reporting have been allocated to
Receiver 1 for domestic dialling.
This means that the zone status reports including zone bypass, zone trouble, sensor watch and alarm restore codes as well as system status reports including fuse fail, AC fail, low battery and access denied reports have been allocated to Receiver 2 and will not report unless Receiver 2 has also been set up to report.
Electronics Design and Manufacturing Pty Limited ISSUE140
Solution 844/862/880
Installation Manual
?"GG1':(X,,(Y(H'18#7+F&018#7(T$%"G1%&9(!%755&'6(>;(\"91%&"'0(
This command allows automatic stepping of locations while programming via Installer’s
Programming Mode. When enabled via the hand held programmer, the decimal point of the left most display will reflect the mode of operation.
If the decimal point is illuminated on the hand held programmer, automatic stepping of locations is active. An automatic increment of the location being programmed will occur as soon as the
*
button is pressed positioning you at the next location ready for programming.
If the decimal point is not illuminated on the hand held programmer, the automatic stepping of locations is disabled and programming the next location will need to be manually selected by pressing the
#
button. As you can see from the examples below, auto step mode can be very useful when programming successive locations.
When programming via the remote codepad, there are no visual indications to display if automatic stepping of locations has been enabled.
C"D(3"(H'18#7(T$%"G1%&9(!%755&'6(>;(\"91%&"'0(
1.
2.
Enter Installer’s Programming Mode (i.e.
1234
followed by the
#
button).
Two beeps will be heard.
If you are using the remote codepad, the
STAY
and
AWAY
indicators will begin to flash to indicate that you have entered Installer’s Programming Mode. You will also notice that the remote codepad will display the data currently programmed in “LOCATION
000”.
Enter command
966
followed by the
#
button.
Two beeps will be heard.
HI1G5#7(
C"D(3"(F&018#7(T$%"G1%&9(!%755&'6(>;(\"91%&"'0(
1.
Enter command
966
followed by the
#
button.
Two beeps will be heard.
(Auto Step Enabled)
To enter the Primary Telephone Number "02 pause 9672 1055" with auto step enabled (i.e.
Decimal point illuminated when using the hand held programmer).
Press
0
followed by the
#
button.
(This will position you at "LOCATION 000" being the start of the Primary Telephone Number
For Receiver 1).
+
*
+
2
+
*
+
+
2
+
*
+
1
+
*
+
*
+
*
+
9
+
*
+
6
+
*
+
7
+
*
+
*
+
5
+
*
+
5
+
*
+
0
+
ISSUE140 Electronics Design and Manufacturing Pty Limited
Programming
HI1G5#7(
45
(Auto Step Disabled)
To enter the Primary Telephone Number "02 pause 9672 1055" with auto step disabled (i.e.
Decimal point extinguished when using the hand held programmer).
Press
0
followed by the
#
button.
(This will position you at "LOCATION 000" being the start of the Primary Telephone Number
For Receiver 1).
+
*
+
#
+
2
+
*
+
#
+ +
*
+
#
+
9
+
*
+
#
+
6
+
*
+
#
+
7
+
*
+
#
+
2
+
*
+
#
+
1
+
*
+
#
+ +
*
+
#
+
5
+
*
+
#
+
5
+
*
+
#
+
0
+
*
Electronics Design and Manufacturing Pty Limited ISSUE140
Solution 844/862/880
Installation Manual
?"GG1':(XXX(Y(F&05#1=(K1'7#(3=57(><(!";%D1<7(P7<0&"'(E$G87<(
When using this command via the remote codepad, the codepad will display the panel version of the control panel. As there are three different control panel’s using the same PCB, it is difficult to know which control panel the PCB has been set up to be.
The codepad will display a 4, 6 or 8 depending on the software of the control panel. Refer to the “Table 9: Control Panel Type” below for more information.
/':&91%"<( ?"'%<"#(K1'7#(3=57(
4
Solution 844
6
Solution 862
8
Solution 880
Table 9: Control Panel Type
When using this command via the hand held programmer, the hand held programmer will display the software version number of the control panel.
C"D(3"(F&05#1=(347(?"'%<"#(K1'7#(3=57(><(!";%D1<7(P7<0&"'(E$G87<(
1.
2.
3.
Enter Installer’s Programming Mode (i.e.
1234
followed by the
#
button).
Two beeps will be heard and the data currently programmed in “LOCATION 000” will be displayed via the hand held programmer or remote codepad.
If you are using the remote codepad, the STAY and AWAY indicators will begin to flash to indicate that you have entered Installer’s Programming Mode.
Enter command
999
followed by the
#
button.
Two beeps will be heard.
If you are using the hand held programmer, the right display will indicate the software version number of the control panel.
If you are using the remote codepad, the codepad will display a zone indicator corresponding to the control panel type. Refer to “Table 9: Control Panel Type” above for more information.
Press the
#
button to exit this command and return to the Installer’s Programming
Mode.
4.
Enter command
960
followed by the
#
button to exit Installer's Programming
Mode. Two beeps will be heard and the system will now return to the disarmed state.
If you are using the remote codepad, the STAY and
ISSUE140 Electronics Design and Manufacturing Pty Limited
AWAY indicate that you have returned to the disarmed state.
indicators will extinguish to
Programming
LOCATION 900
47
F&018#7(@19%"<=(F7;1$#%(
0
This feature prevents the control panel from being manually defaulted via the default button or to prevent using a programming key to perform an automatic download to the control panel when the system is disarmed.
A zero programmed into this location will allow defaulting of the control panel. If 15 has been programmed into this location, defaulting of the control panel will not be permitted and the
Installer Code MUST be used for further programming of the control panel.
If the Installer Code is not known, the control panel will need to be returned to your EDM
Distributor for exchange. A nominal fee applies for this service.
Electronics Design and Manufacturing Pty Limited does not recommend the use of this feature.
If the option is required to disable the option of being able to default the control panel, a special procedure has been implemented to eliminate the possibility of accidentally setting this option. The default button on the PCB must be held down while programming this location.
C"D(3"(K<7M7'%(21'$1#(F7;1$#%&'6(>;(347(?"'%<"#(K1'7#(
1.
2.
3.
4.
5.
6.
Enter Installer’s Programming Mode (i.e.
1234
followed by the
#
button).
Two beeps will be heard and the data currently programmed in “LOCATION 000” will be displayed via the hand held programmer or remote codepad.
If you are using a remote codepad, the STAY and AWAY indicators will begin to flash to indicate that Installer’s Programming Mode has been accessed.
From the hand held programmer or remote codepad, go to "LOCATION 900".
(e.g.
900
followed by the
#
button).
Hold down and continue to hold down the DEFAULT button.
The default button will be located at the top of the PCB next to the PROGRAMMING
KEY connecting socket.
Program a 15 into "LOCATION 900".
(e.g.
15
followed by the
*
button).
Release the default button.
Enter command
960
followed by the
#
button to exit Installer's Programming
Mode. Two beeps will be heard and the system will return to the disarmed state.
If you are using a remote codepad, the
STAY
and
AWAY
indicators will extinguish to indicate that the system has returned to the disarmed state.
Electronics Design and Manufacturing Pty Limited ISSUE140
ISSUE140
Solution 844/862/880
Installation Manual
F7;1$#%&'6(347(?"'%<"#(K1'7#(
If the
Solution 844/862/880
control panel does not have "LOCATION 900" programmed as 15, follow the procedure outlined below to successfully default the control panel back to the factory default settings.
C"D(3"(F7;1$#%(347(?"'%<"#(K1'7#(P&1(/'0%1##7<(?":7(
1.
2.
Enter Installer Programming Mode.
(e.g.
1234
followed by the
#
button). Two beeps will be heard. The STAY and
AWAY indicators will begin to flash to indicate that you have accessed programming mode.
Enter Installer’s Programming Command
965
followed by the
#
button.
Two beeps will be heard after the control panel has successfully been defaulted.
3.
Enter Installer’s Programming Command 960 followed by the # button.
Two beeps will be heard. The
STAY
and
AWAY
indicators will cease to flash and the system will return to the disarmed state.
The control panel has now been successfully defaulted back to the factory default settings.
C"D(3"(F7;1$#%(347(?"'%<"#(K1'7#(P&1(F7;1$#%(V$%%"'(
1.
2.
3.
4.
5.
Disconnect the AC mains supply and the backup battery from the control panel.
Hold down and continue to hold down the DEFAULT button.
The default button is located at the top of the PCB next to the PROGRAMMING KEY connecting socket.
Reconnect the AC mains supply to the control panel.
After reconnecting the AC mains supply, wait for 3-5 seconds before releasing the
DEFAULT button.
Disarm the system using the default Master Code (e.g. Enter
2580
followed by the
#
button).
The control panel has now been successfully defaulted back to the factory default settings.
If you hear the dialler seize relay (RL2) click four times while attempting to default the control panel, this would indicate that the feature of defaulting the control panel has been disabled in “LOCATION 900” on page 47. The control panel will need to be returned to Electronics Design and Manufacturing Pty Limited for exchange where a service fee will be charged to unlock the control panel's memory if the Installer Code is not known.
Electronics Design and Manufacturing Pty Limited
(
?":751:(/':&91%"<0(
Solution 844/862/880
Installation Manual
?KR(H&64%(J"'7(\HF(?":751:(
The codepad is the communications interface between you and your alarm system. The codepad allows you to issue commands and offers both visual and audible indications that guide you through the general operation.
The codepad incorporates numerous indicators. There are ZONE indicators that are used to show the condition of each zone and four others for general status. The following is a list of situations and the relevant indications that will be seen.
Figure 1: CP5 Eight Zone Codepad (CP508)
J"'7(/':&91%"<0(
The
ZONE
indicators are used to display the status of the zones. The following table lists the various circumstances that the indicators will display (i.e. Zone Sealed, Zone Unsealed).
/':&91%"<(
On
Off
Flashing Fast
(0.25 Sec On – 0.25 Sec Off)
Flashing Slow
(1 Sec On – 1 Sec Off)
Zone Is Unsealed
F7;&'&%&"'(
Zone Is Sealed
Zone Is In Alarm Condition
Zone Is Manually Isolated
Table 10: Zone Indicators
TOT](/':&91%"<(
The
AWAY
indicator is used to display that the system is armed in
AWAY
Mode. The
AWAY indicator will also flash in unison with the STAY indicator when Installer’s Programming Mode or Master Code Functions are used.
Refer to page 62 for more information on the different methods on arming the system in
AWAY Mode.
/':&91%"<( F7;&'&%&"'(
On
System Is Armed In AWAY Mode
Off
System Is Not Armed In AWAY Mode
Table 11: AWAY Indicator
ISSUE140 Electronics Design and Manufacturing Pty Limited
Codepad Indicators 51
!3T](/':&91%"<(
The
STAY
indicator is used to display that the system is armed in STAY Mode 1 or STAY
Mode 2. The STAY indicator will also flash in unison with the AWAY indicator when
Installer’s Programming Mode or Master Code Functions are used.
For the different methods of arming the system in STAY Mode 1, refer to page 64. Refer to
Zone Options 1 on page 173 for information on setting zones to be automatically isolated in
STAY Mode 1. For the method of arming the system in STAY Mode 2, refer to page 67.
Refer to Setting STAY Mode 2 Zones on page 95 when using the Installer Code or Setting
STAY Mode 2 Zones on page 111 when using the Master Code.
/':&91%"<(
On
Off
Flashing
F7;&'&%&"'(
System Is Armed In STAY Mode 1 Or STAY Mode 2
System Is Not Armed In STAY Mode
Zone Isolating Mode Or Setting STAY Mode 2 Zones
Table 12: STAY Indicator
2T/E!(/':&91%"<(
The
MAINS
indicator is used to display that the systems AC mains supply is normal or has failed.
When programming numbers (i.e. Installer’s Programming Mode or Master Code Functions), the
MAINS
indicator will illuminate when you program numbers between 10 and 15. The
MAINS indicator represents digit 10 plus the value of the illuminated zone indicator (e.g.: If you program a twelve, the MAINS indicator and zone 2 will illuminate).
/':&91%"<(
On
Flashing
F7;&'&%&"'(
AC Mains Power Normal
AC Mains Failure
Table 13: MAINS Indicator
@TZ\3(/':&91%"<(
The
FAULT
indicator is used to display that the system has detected a system fault. Refer to
Fault Analysis Mode on page 73 for more information on system faults.
Every time a new system fault has been detected (e.g.: FAULT indicator flashing), the codepad will begin to beep once every minute.
Pressing the button once will cancel the once a minute beep and acknowledge the fault
(e.g.: FAULT indicator on).
/':&91%"<(
On
Off
Flashing
F7;&'&%&"'(
There Is A System Fault That Needs To Be Rectified
The System Is Normal, There Are No Faults
There Is A System Fault Waiting To Be Acknowledged
Table 14: FAULT Indicator
Electronics Design and Manufacturing Pty Limited ISSUE140
Solution 844/862/880
Installation Manual
T$:&8#7(/':&91%"<0(
In general, the audible indications given out by the codepad are as follows:
/':&91%"<( F7;&'&%&"'(
One Short Beep
A Button Has Been Pressed On The Codepad Or End
Of Exit Time When Armed In Either STAY Mode 1 Or
STAY Mode 2
Two Short Beeps
The System Has Accepted Your Code
Three Short Beeps
One Long Beep
The Requested Function Has Been Executed
Indicates The End Of Exit Time In AWAY Mode Or
The Requested Operation Has Been Denied Or Aborted
Walk Test Mode Is Currently Active Or Warning
Before Automatic Arming Takes Place
One Short Beep Every Second
One Short Beep Every Two
Seconds
Telephone Monitor Mode Is Active
One Short Beep Every Minute
There Is A System Fault Waiting To Be Acknowledged
Table 15: Audible Indications
ISSUE140 Electronics Design and Manufacturing Pty Limited
Codepad Indicators 53
?KR(H&64%(J"'7(\?F(?":751:(
The codepad is the communications interface between you and your alarm system. The codepad allows you to issue commands and offers both visual and audible indications that guide you through the general operation.
The codepad incorporates numerous indicators. There are ZONE indicators that are used to show the condition of each zone and seven others for general status. The following is a list of situations and the relevant indications that will be seen.
Figure 2: CP5 Eight Zone LCD Codepad
(CP508L)
1 2 3 ....
J"'7(/':&91%"<0(
The
ZONE
indicators are used to display the status of the zones. The following table lists the various circumstances that the indicators will display (i.e. Zone Sealed, Zone Unsealed).
/':&91%"<( F7;&'&%&"'(
On
Zone Is Unsealed
Off
Flashing Fast
(0.25 Sec On – 0.25 Sec Off)
Flashing Slow
(1 Sec On – 1 Sec Off)
Zone Is Sealed
Zone Is In Alarm Condition
Zone Is Manually Isolated
Table 16: Zone Indicators
TOT](/':&91%"<(
The
AWAY
indicator is used to display that the system is armed in
AWAY
Mode. The indicator will also illuminate when the system is armed in AWAY Mode. The
AWAY
indicator will also flash in unison with the STAY indicator when Installer’s Programming Mode or
Master Code Functions are used.
Refer to page 62 for more information on the different methods on arming the system in
AWAY Mode.
/':&91%"<(
On
Off
F7;&'&%&"'(
System Is Armed In AWAY Mode
System Is Not Armed In AWAY Mode
Table 17: AWAY Indicator
Electronics Design and Manufacturing Pty Limited ISSUE140
Flashing
ISSUE140
Solution 844/862/880
Installation Manual
!3T](/':&91%"<(
The STAY indicator is used to display that the system is armed in STAY Mode 1 or STAY
Mode 2. The STAY indicator will also flash in unison with the AWAY indicator when
Installer’s Programming Mode or Master Code Functions are used.
The
Mode 2.
indicator will also illuminate when the system is armed in STAY Mode 1 or STAY
For the different methods of arming the system in STAY Mode 1, refer to page 64. Refer to
Zone Options 1 on page 173 for information on setting zones to be automatically isolated in
STAY Mode 1. For the method of arming the system in STAY Mode 2, refer to page 67.
Refer to Setting STAY Mode 2 Zones on page 95 when using the Installer Code or Setting
STAY Mode 2 Zones on page 111 when using the Master Code.
/':&91%"<(
On
Off
Flashing
F7;&'&%&"'(
System Is Armed In STAY Mode 1 Or STAY Mode 2
System Is Not Armed In STAY Mode
Zone Isolating Mode Or Setting STAY Mode 2 Zones
Table 18: STAY Indicator
!=0%7G(F&01<G7:(
This indicator will illuminate with the indicator when the system has been disarmed.
2T/E!(/':&91%"<(
The
MAINS
indicator is used to display that the systems AC mains supply is normal or has failed.
When programming numbers (i.e. Installer’s Programming Mode or Master Code Functions), the
MAINS
indicator will illuminate when you program numbers between 10 and 15. The
MAINS indicator represents digit 10 plus the value of the illuminated zone indicator (e.g.: If you program a twelve, the MAINS indicator and zone 2 will illuminate).
/':&91%"<(
On
Flashing
F7;&'&%&"'(
AC Mains Power Normal
AC Mains Failure
Table 19: MAINS Indicator
J"'7(/0"#1%&'6(2":7(
This indicator will illuminate and flash every 3 seconds when you attempt to manually isolate zones or when the installer or Master Code holder programs zones to be automatically isolated for STAY Mode 2.
Refer to Isolating Zones on page 70 for information on how to manually isolate zones. Refer to Setting STAY Mode 2 Zones on page 95 when using the Installer Code or Setting STAY
Mode 2 Zones on page 111 when using to Master Code to program zones to be automatically isolated in STAY Mode 2.
Electronics Design and Manufacturing Pty Limited
Codepad Indicators 55
@TZ\3(/':&91%"<(
The
FAULT
indicator is used to display that the system has detected a system fault. Refer to
Fault Analysis Mode on page 73 for more information on system faults.
Every time a new system fault has been detected (e.g.: FAULT indicator flashing), the codepad will begin to beep once every minute.
Pressing the button once will cancel the once a minute beep and acknowledge the fault
(e.g.: FAULT indicator on).
/':&91%"<( F7;&'&%&"'(
On
There Is A System Fault That Needs To Be Rectified
The System Is Normal, There Are No Faults
Off
Flashing
There Is A System Fault Waiting To Be Acknowledged
Table 20: FAULT Indicator
K<"6<1GG&'6(2":7(
These two indicators will flash when the system has entered either Installer’s Programming
Mode or when any Master Code Functions are used.
Flashing
>;;(/':&91%"<+J"'7(!71#7:(
The indicator will illuminate when the system is in the disarmed state or Installer’s
Programming Mode has been entered and will flash when a zone becomes unsealed during the disarmed state. The indicator will stop flashing when all zones are sealed.
>'(/':&91%"<+J"'7(/'(T#1<G(
The indicator will illuminate when the system is armed in
AWAY
Mode and will flash when an alarm occurs. The indicator will reset once a valid user code has been entered.
Electronics Design and Manufacturing Pty Limited ISSUE140
Solution 844/862/880
Installation Manual
T$:&8#7(/':&91%"<0(
In general, the audible indications given out by the codepad are as follows:
/':&91%"<(
One Short Beep
F7;&'&%&"'(
A Button Has Been Pressed On The Codepad Or End
Of Exit Time When Armed In Either STAY Mode 1 Or
STAY Mode 2
Two Short Beeps
The System Has Accepted Your Code
Three Short Beeps
One Long Beep
The Requested Function Has Been Executed
Indicates The End Of Exit Time In AWAY Mode Or
The Requested Operation Has Been Denied Or Aborted
Walk Test Mode Is Currently Active Or Warning
Before Automatic Arming Takes Place
One Short Beep Every Second
One Short Beep Every Two
Seconds
Telephone Monitor Mode Is Active
One Short Beep Every Minute
There Is A System Fault Waiting To Be Acknowledged
Table 21: Audible Indications
ISSUE140 Electronics Design and Manufacturing Pty Limited
Codepad Indicators
Figure 3: CP5 Master Partitioned LED
Codepad (CP500P)
?KR(210%7<(K1<%&%&"'7:(\HF(?":751:(
57
This codepad is only used on the
Solution 880
control panel when partitioned. The Master Partitioned LED codepad will allow the user to operate both areas individually from the same codepad, without the need to operate individual areas from separate codepads.
The codepad is the communications interface between you and your alarm system. The codepad allows you to issue commands and offers both visual and audible indications that guide you through the general operation.
The codepad incorporates numerous indicators. There are
ZONE
indicators that are used to show the condition of each zone and four others for general status. The following is a list of situations and the relevant indications that will be seen.
Refer to Partitioning on page 237 for more information.
The indicators on the CP5 Master Partitioned LED codepad are configured in to four groups.
Following is a description of what the indicators mean.
N(
J"'7(/':&91%"<0(
The
ZONE
indicators are used to display the status of the zones. The following table lists the various circumstances that the indicators will display (i.e. Zone Sealed, Zone Unsealed).
/':&91%"<( F7;&'&%&"'(
On
Off
Flashing Fast
(0.25 Sec On – 0.25 Sec Off)
Flashing Slow
(1 Sec On – 1 Sec Off)
Zone Is Unsealed
Zone Is Sealed
Zone Is In Alarm Condition
Zone Is Manually Isolated
Table 22: Zone Indicators
-(
T<71(>'+>;;(/':&91%"<0(
The group of four Area On/Off indicators (1 – 4) show the status of each area (i.e. If an indicator is illuminated, that area is armed and if the indicator is not illuminated, that area is disarmed).
If an area is armed in STAY Mode 1, the corresponding Area On/Off indicator will be illuminated in conjunction with the PARTIAL indicator. If the area is armed in AWAY Mode, only the corresponding Area On/Off Indicator will be illuminated.
T<71(>'+>;;(/':&91%"<(
On
Off
F7;&'&%&"'(
Area Is Armed In AWAY Mode Or STAY Mode 1
Area Is Disarmed
Table 23: Area On/Off Indicators
Electronics Design and Manufacturing Pty Limited ISSUE140
ISSUE140
Q(
*(
Solution 844/862/880
Installation Manual
T<71(F&05#1=(/':&91%"<0(
A group of four Area Display indicators display which area is currently being displayed (i.e. If number 1 is being displayed, all information provided on the codepad display relates only to
Area 1. If number 2 is being displayed, all information provided on the codepad display relates only to Area 2).
Pressing the button will toggle or move you to the next area display (i.e. If Area 1 is currently being displayed, pressing the button will toggle or move you to Area 2.
Pressing the
1).
button a second time will toggle you back to display information for Area
T<71(F&05#1=(/':&91%"<0( F7;&'&%&"'(
On
Indicates Current Area Being Displayed
Off
Indicates Current Area Not Being Displayed
Table 24: Area Display Indicators
!%1%$0(/':&91%"<0(
A group of four indicators display the following:
KTL3/T\(/':&91%"<(
The
PARTIAL
indicator is used to display that the system is armed in
STAY
Mode 1. The
PARTIAL indicator will also flash in unison with the AUX indicator when Installer’s
Programming Mode or Master Code Functions are used.
For the different methods of arming the system in STAY Mode 1, refer to page 64. Refer to
Zone Options 1 on page 173 for information on setting zones to be automatically isolated in
STAY Mode 1.
/':&91%"<( F7;&'&%&"'(
On
System Is Armed In STAY Mode 1
Off
System Is Not Armed In STAY Mode 1
Table 25: Partial Indicator
TZ^(/':&91%"<(
If Option 8 in “LOCATION 432” on page 243 has been enabled, the
AUX
indicator will be used to display when the control panel is using the telephone line. The AUX indicator will also flash in unison with the
PARTIAL
indicator when Installer’s Programming Mode or Master
Code Functions are used.
/':&91%"<(
On
Off
Flashing
F7;&'&%&"'(
System Is Armed In STAY Mode 1 Or STAY Mode 2
System Is Not Armed In STAY Mode
Zone Isolating Mode Or Setting STAY Mode 2 Zones
Table 26: AUX Indicator
Electronics Design and Manufacturing Pty Limited
Codepad Indicators 59
2T/E!(/':&91%"<(
The MAINS indicator is used to display that the systems AC mains supply is normal or has failed.
When programming numbers (i.e. Installer’s Programming Mode or Master Code Functions), the MAINS indicator will illuminate when you program numbers between 10 and 15. The
MAINS
indicator represents digit 10 plus the value of the illuminated zone indicator (e.g.: If you program a twelve, the
MAINS
indicator and zone 2 will illuminate).
/':&91%"<(
On
Flashing
F7;&'&%&"'(
AC Mains Power Normal
AC Mains Failure
Table 27: MAINS Indicator
@TZ\3(/':&91%"<(
The FAULT indicator is used to display that the system has detected a system fault. Refer to
Fault Analysis Mode on page 73 for more information on system faults.
Every time a new system fault has been detected (e.g.: FAULT indicator flashing), the codepad will begin to beep once every minute.
Pressing the button once will cancel the once a minute beep and acknowledge the fault
(e.g.:
FAULT
indicator on).
/':&91%"<(
On
Off
Flashing
F7;&'&%&"'(
There Is A System Fault That Needs To Be Rectified
The System Is Normal, There Are No Faults
There Is A System Fault Waiting To Be Acknowledged
Table 28: FAULT Indicator
T$:&8#7(/':&91%"<0(
In general, the audible indications given out by the codepad are as follows:
/':&91%"<( F7;&'&%&"'(
One Short Beep
A Button Has Been Pressed On The Codepad Or End
Of Exit Time When Armed In Either STAY Mode 1 Or
STAY Mode 2
Two Short Beeps
The System Has Accepted Your Code
Three Short Beeps
One Long Beep
The Requested Function Has Been Executed
Indicates The End Of Exit Time In AWAY Mode Or
The Requested Operation Has Been Denied Or Aborted
Walk Test Mode Is Currently Active Or Warning
Before Automatic Arming Takes Place
One Short Beep Every Second
One Short Beep Every Two
Seconds
Telephone Monitor Mode Is Active
One Short Beep Every Minute
There Is A System Fault Waiting To Be Acknowledged
Table 29: Audible Indications
Electronics Design and Manufacturing Pty Limited ISSUE140
Solution 844/862/880
Installation Manual
ISSUE140 Electronics Design and Manufacturing Pty Limited
(
!=0%7G(>57<1%&"'0(
!=0%7G(>57<1%&"'0(
This section explains the general operations of the system. The operations will explain how to arm and disarm the system in the various modes, how to isolate zones, initiate codepad alarms and determine any fault that may occur.
T<G&'6(347(!=0%7G(/'(TOT](2":7(
Arming the system in AWAY Mode is normally performed when you leave the premises and require that all zones be activated in a ready state to detect any intrusion.
There are two different methods for arming the system in AWAY Mode. Method one is standard and will always operate. Method two is optional and needs Option 2 in "LOCATION
429" to be enabled on page 234.
If you require to isolate a zone(s) prior to arming the system in AWAY Mode, refer to Isolating
Zones on page 70.
Solution 844/862/880
Installation Manual
Single button arming in AWAY Mode will report as user code number 16.
27%4":(>'7(
C"D(3"(T<G(347(!=0%7G(/'(TOT](2":7(
1.
Enter your followed by the button.
Two beeps will be heard and the AWAY indicator will illuminate. Exit time will now commence.
+
27%4":(3D"(
C"D(3"(T<G(347(!=0%7G(/'(TOT](2":7(
1.
Hold down the button until two beeps are heard.
The AWAY indicator will illuminate and exit time will now commence. Refer to Option
2 in "LOCATION 429" on page 234 to enable single button arming in AWAY Mode.
If a zone is not sealed at the end of exit time, the zone will be automatically isolated and will be constantly illuminated on the remote codepad. The zone will become an active part of the system again as soon as it has resealed (i.e.. If a window is left open after exit time has expired, the window will not be an active part of the system until it has closed. Opening the window after exit time has expired will cause an alarm condition).
@"<97:(T<G&'6(
The feature of arming the system when a zone is not sealed is known as forced arming. Refer to Zone Options 2 on page 183 to enable forced arming for each zone.
If the AWAY indicator does not illuminate and a long beep is heard when attempting to arm the system in AWAY Mode, forced arming is not permitted. If this is the case, you must ensure that all zones are sealed or manually isolated before you can arm the system.
ISSUE140 Electronics Design and Manufacturing Pty Limited
System Operations 63
F&01<G&'6(347(!=0%7G(@<"G(TOT](2":7(
When you enter the premises after the system has been armed in AWAY Mode, you will need to disarm the system from AWAY Mode to disable detection devices that will activate the sirens, strobe and bell outputs.
If there has been an alarm condition prior to disarming the system from AWAY Mode, a flashing ZONE indicator will be displayed, indicating a previous alarm on that zone.
C"D(3"(F&01<G(347(!=0%7G(@<"G(TOT](2":7(
1.
Enter your followed by the button.
Two beeps will be heard and the AWAY indicator will extinguish.
+
Electronics Design and Manufacturing Pty Limited ISSUE140
Solution 844/862/880
Installation Manual
T<G&'6(347(!=0%7G(/'(!3T](2":7(N(
Arming the system in STAY Mode 1 is only used when the perimeter and unused areas of the premises need to be armed to detect any would be intruder from entering the premises, at the same time allowing you to move freely within an area which has been automatically isolated.
Programming zones to be automatically isolated in STAY Mode 1 can only be programmed by the installer. Refer to Zone Options 2 on page 183 for further information on setting zones to be automatically isolated in STAY Mode 1.
There are two methods for arming your system in STAY Mode 1. Method one is standard and will always operate. Method two is optional and needs Option 2 in "LOCATION 429" to be enabled on page 234.
H'%<=(_$1<:(3&G7<(@"<(!3T](2":7(
When arming the system in STAY Mode 1, an optional entry timer called Entry Guard Timer
For STAY Mode may be used to delay the sirens, strobe and bell outputs if a zone that has not been automatically isolated has triggered into alarm condition. Entry Guard Timer For STAY
Mode is the delay time used for all zones except 24 hour zones when the system is armed in
STAY Mode 1 or STAY Mode 2.
If the Entry Guard Timer For STAY Mode has been programmed and a zone that has not been automatically isolated has triggered, the codepad will beep twice a second until the Entry
Guard Timer For STAY Mode has expired or the system has been disarmed. If the alarm condition has not been reset before Entry Guard Timer For STAY Mode expires, the strobe, bell and siren outputs will activate into alarm.
Single button arming in STAY Mode 1 will report as user code number 16.
27%4":(>'7(
C"D(3"(T<G(347(!=0%7G(/'(!3T](2":7(N(
1.
Enter your followed by the button.
Two beeps will be heard and the STAY indicator will illuminate. Exit time will now commence.
Any zones that have been programmed to be automatically isolated in STAY Mode 1 will begin to flash until exit time expires. At the end of exit time, the
ZONE
indicators will extinguish and the codepad will give one short beep.
+
ISSUE140 Electronics Design and Manufacturing Pty Limited
System Operations
27%4":(3D"(
C"D(3"(T<G(347(!=0%7G(/'(!3T](2":7(N(
1.
65
Hold down the button until two beeps are heard.
The STAY indicator will illuminate and exit time will now commence.
Any zones that have been programmed to be automatically isolated in STAY Mode 1 will begin to flash until exit time expires. At the end of exit time, the ZONE indicators will extinguish and the codepad will give one short beep.
If a zone is not sealed at the end of exit time, the zone will be automatically isolated and will be constantly illuminated on the remote codepad. The zone will become an active part of the system again as soon as it has resealed (i.e.. If a window is left open after exit time has expired, the window will not be an active part of the system until it has closed. Opening the window after exit time has expired will cause an alarm condition).
@"<97:(T<G&'6(
The feature of arming the system when a zone is not sealed is known as forced arming. Refer to Zone Options 2 on page 183 to enable forced arming for each zone.
If the
STAY
indicator does not illuminate and a long beep is heard when attempting to arm the system in STAY Mode 1, forced arming is not permitted. If this is the case, you must ensure that all zones are sealed or manually isolated before you can arm the system.
Electronics Design and Manufacturing Pty Limited ISSUE140
Solution 844/862/880
Installation Manual
F&01<G&'6(347(!=0%7G(@<"G(!3T](2":7(N(
There are two methods for disarming the system from STAY Mode 1. Method one is standard and will always operate. Method two is optional and needs Option 4 to be enabled in
"LOCATION 429" on page 234.
Method two will not operate unless both Option 2 and Option 4 has been enabled in
"LOCATION 429" on page 234.
27%4":(>'7(
C"D(3"(F&01<G(347(!=0%7G(@<"G(!3T](2":7(N(
1.
Enter your followed by the button.
Two beeps will be heard and the
STAY
indicator will extinguish. The system is now disarmed.
+
27%4":(3D"(
A flashing ZONE indicator represents a previous alarm on that zone. If this is the case, a valid user code will need to be used to disarm the system using method one. To enable method two,
Option 4 in "LOCATION 429" on page 234 will need to be enabled.
C"D(3"(F&01<G(347(!=0%7G(@<"G(!3T](2":7(N(
1.
Hold down the button until two beeps are heard.
The
STAY
indicator will extinguish and the system is now disarmed.
Single button disarming from STAY Mode 1 will report as user code number 16.
ISSUE140 Electronics Design and Manufacturing Pty Limited
System Operations 67
T<G&'6(347(!=0%7G(/'(!3T](2":7(-(
Arming the system in STAY Mode 2 is only used when the perimeter and unused areas of the premises need to be armed to detect any would be intruder from entering the premises, at the same time allowing you to move freely within an area which has been automatically isolated.
Programming zones to be automatically isolated in STAY Mode 2 can be programmed either by the Installer Code Function – Setting STAY Mode 2 Zones on page 95 or Master Code
Functions - Setting STAY Mode 2 Zones on page 111.
H'%<=(_$1<:(3&G7<(@"<(!3T](2":7(
When arming the system in STAY Mode 2, an optional entry timer called Entry Guard Timer
For STAY Mode may be used to delay the sirens, strobe and bell outputs if a zone that has not been automatically isolated has triggered into alarm condition. Entry Guard Timer For STAY
Mode is the delay time used for all zones except 24 hour zones when the system is armed in
STAY Mode 1 or STAY Mode 2.
If the Entry Guard Timer For STAY Mode has been programmed and a zone that has not been automatically isolated has triggered, the codepad will beep twice a second until the Entry
Guard Timer For STAY Mode has expired or the system has been disarmed. If the alarm condition has not been reset before Entry Guard Timer For STAY Mode expires, the strobe, bell and siren outputs will activate into alarm.
Single button arming in STAY Mode 2 will report as user code number 16.
C"D(3"(T<G(347(!=0%7G(/'(!3T](2":7(-(
1.
Hold down the
0
button until two beeps are heard.
The STAY indicator will illuminate and exit time will now commence.
Any zones that have been programmed to be automatically isolated in STAY Mode 2 will begin to flash until exit time expires. At the end of exit time, the ZONE indicators will extinguish and the codepad will give one short beep.
0
If a zone is not sealed at the end of exit time, the zone will be automatically isolated and will be constantly illuminated on the remote codepad. The zone will become an active part of the system again as soon as it has resealed (i.e.. If a window is left open after exit time has expired, the window will not be an active part of the system until it has closed. Opening the window after exit time has expired will cause an alarm condition).
@"<97:(T<G&'6(
The feature of arming the system when a zone is not sealed is known as forced arming. Refer to Zone Options 2 on page 183 to enable forced arming for each zone.
If the STAY indicator does not illuminate and a long beep is heard when attempting to arm the system, forced arming is not permitted. If this is the case, you must ensure that all zones are sealed or manually isolated before you can arm the system.
Electronics Design and Manufacturing Pty Limited ISSUE140
Solution 844/862/880
Installation Manual
F&01<G&'6(347(!=0%7G(@<"G(!3T](2":7(-(
There are two methods for disarming the system from STAY Mode 2. Method one is standard and will always operate. Method two is optional and needs Option 4 to be enabled in
"LOCATION 429" on page 234.
Method two will not operate unless both Option 2 and Option 4 has been enabled in
"LOCATION 429" on page 234.
27%4":(>'7(
C"D(3"(F&01<G(347(!=0%7G(@<"G(!3T](2":7(-(
1.
Enter your followed by the button.
Two beeps will be heard and the
STAY
indicator will extinguish. The system is now disarmed.
+
27%4":(3D"(
A flashing ZONE indicator represents a previous alarm on that zone. If this is the case a valid user code will need to be used to disarm the system using method one. To enable method two,
Option 4 in "LOCATION 429" on page 234 will need to be programmed.
C"D(3"(F&01<G(347(!=0%7G(@<"G(!3T](2":7(-(
1.
Hold down the
0
button until two beeps are heard.
The
STAY
indicator will extinguish and the system is now disarmed.
0
Single button disarming from STAY Mode 2 will report as user code number 16.
ISSUE140 Electronics Design and Manufacturing Pty Limited
69 System Operations
?":751:(F$<700(T#1<G(
A codepad duress alarm is used as a silent hold up alarm. This will only occur when the number
9
is added to the end of any valid user code that is being used to disarm the system.
However, if a user code has a priority level of arming only, entering their user code followed by 9 will still transmit a duress alarm when the system is armed.
A duress alarm (Contact ID Event Code 121) is only useful if your system is reporting back to a monitoring station or pocket pager as domestic reporting format can’t decipher which type of alarm had occurred. If you wish to disable the codepad duress alarm report, refer to
“LOCATION 336” on page 192 for more information. If you require to activate a duress alarm by adding a number 3 to the end of any valid user code being used to disarm the system, enable
Option 2 in “LOCATION 430” on page 235.
+
9
+
?":751:(K1'&9(T#1<G(
An audible codepad panic alarm will be activated when both the
1
and
3
buttons or both the and buttons are pressed simultaneously.
Refer to Option 1 in "LOCATION 425" on page 230 if you wish to program codepad panic to be silent. If you wish to disable the codepad panic alarm report, refer to
“LOCATION 337 - 338” on page 192 for more information. A codepad panic alarm will transmit a Contact ID Event Code 120 when reporting back to a base station receiver.
1
+
3
or
+
?":751:(@&<7(T#1<G(
Figure 4: CP5 LED Codepad
Showing Audible Alarm Buttons
An audible codepad fire alarm will be activated when both the
4
and
6
buttons on the remote codepad are pressed simultaneously. A distinct fire sound is emitted through the horn speaker to indicate this type of alarm condition. The fire sound is different to the burglary sound.
Refer to Option 2 in "LOCATION 425" on page 230 if you wish to program codepad fire to be silent. If you wish to disable the codepad fire alarm report, refer to
“LOCATION 339 - 340” on page 193 for more information. A codepad fire alarm will transmit a Contact ID Event Code 110 to a base station receiver.
4
+
6
?":751:(27:&91#(T#1<G(
An audible codepad medical alarm will be triggered when both the
7
and
9
buttons on the remote codepad are pressed simultaneously.
Refer to Option 4 in "LOCATION 425" on page 230 if you wish to program codepad medical to be silent. If you wish to disable the reporting of the codepad medical alarm report, refer to
“LOCATION 341 - 342” on page 193 for more information. A codepad medical alarm will transmit a Contact ID Event Code 100 to a base station receiver.
7
+
9
Electronics Design and Manufacturing Pty Limited ISSUE140
Solution 844/862/880
Installation Manual
/0"#1%&'6(J"'70(
Isolating zones allow you to manually disable one or more zones before arming the system in
AWAY Mode, STAY Mode 1 or STAY Mode 2. Once a zone has been isolated, access is allowed into that zone during the armed state without activating the sirens or dialler.
An example when you may require to isolate a zone before arming in AWAY Mode, STAY
Mode 1 or STAY Mode 2 may be when a zone PIR detector may be false alarming or that you may need to leave a pet inside a particular zone whilst you are away.
Isolating zones is performed by one of two methods. One way requires the use of a valid user code while the other way does not. The ability to isolate zones is governed by the priority level allocated to each user code holder. Some user code holders may not be able to isolate zones.
Refer to User Code Priority on page 165 for further information.
Zones that have been manually isolated using this method will transmit a zone bypass report
(Contact ID Event Code 570) for each zone upon arming the system. A zone bypass restore report will be transmitted when the system has been disarmed.
ISSUE140 Electronics Design and Manufacturing Pty Limited
System Operations 71
!%1':1<:(/0"#1%&'6(
Standard isolating allows all operators to be able to isolate zones. Therefore, no code is required to be used when isolating zones.
1.
2.
3.
Press the button twice.
Three beeps will be heard.
* Enter the required to be isolated followed by the
The zone you just selected to be isolated will now begin to flash.
button.
24 hour zones will automatically isolate as soon as the button has been pressed.
All other burglary zones will automatically isolate only after the system has been armed.
Repeat Step 2 if more than one zone is required to be isolated until all zones that are required to be isolated have been selected.
Press the button when finished selecting the zones to be isolated.
Two beeps will be heard and the system will return to the disarmed state.
The zones selected to be isolated when you arm the system in AWAY Mode, STAY Mode 1 or
STAY Mode 2 will continue to flash until the system has next been disarmed.
+ + + +
*
As each zone is selected to be isolated, the corresponding ZONE indicator will begin to flash. If a mistake is made, press the zone number that was incorrectly entered followed by the button. This zone is now no longer selected to be isolated and the ZONE indicator will extinguish.
HI1G5#7(
If you wish to manually isolate zones 1, 3 and 4, the following sequence would be entered below;
+ +
1
+ +
3
+
+
4
+ +
Electronics Design and Manufacturing Pty Limited ISSUE140
Solution 844/862/880
Installation Manual
?":7(3"(/0"#1%7(
The method of code to isolate restricts only those user codes that have the priority level Code
To Isolate set to be able to isolate zones. Therefore, if any user code has this priority level set, the method of standard isolating will be disabled.
1.
Press the button.
2.
3.
4.
Enter your .
Press the button.
Three beeps will be heard and the STAY indicator will begin to flash. If you attempt to enter isolating mode with a user code that has not been allocated for code to isolate, the system will ignore the attempt to enter the mode.
* Enter the required to be isolated followed by the zone you have just selected to be isolated will now begin to flash.
button. The
5.
24 hour zones will automatically isolate as soon as the button has been pressed.
All other burglary zones will automatically isolate only after the system has been armed.
Repeat Step 4 if more than one zone is required to be isolated until all zones that are required to be isolated have been selected.
Press the button when finished selecting the zones to be isolated.
Two beeps will be heard and the system will return to the disarmed state.
The zones selected to be isolated when you arm the system in AWAY Mode, STAY Mode 1 or
STAY Mode 2 will continue to flash until the system has next been disarmed.
+
+
+
+
+
*
As each zone is selected to be isolated, the corresponding ZONE indicator will begin to flash. If a mistake is made, press the zone number that was incorrectly entered followed by the button. This zone is now no longer selected to be isolated and the ZONE indicator will extinguish.
ISSUE140
HI1G5#7(
If you wish to manually isolate zones 1, 3 and 4, the following sequence would be entered below;
+ +
+
1
+ +
3
+ +
4
+ +
Electronics Design and Manufacturing Pty Limited
System Operations 73
@1$#%(T'1#=0&0(2":7(
Whenever a system fault occurs, the FAULT or MAINS indicator will flash and the codepad will beep once every minute.
If the
MAINS
indicator is flashing, this is because the AC mains supply has been disconnected from the control panel. If the AC mains supply has been disconnected continuously for more than 2 minutes, the control panel will send an “AC Loss” signal (Contact ID Event Code 301) to the base station receiver and the codepad will commence beeping once every minute until the AC mains supply has been reconnected or acknowledged by pressing the button.
When the AC mains supply has been restored, the MAINS indicator will automatically stop flashing and return to its normal state. Once the AC mains supply has been connected continuously for two minutes, the control panel will send an “AC Loss” restore report and the codepad will automatically stop it’s once a minute beep.
C"D(3"(F7%7<G&'7(347(3=57(>;(!=0%7G(@1$#%(
To determine all system faults other than the AC mains supply, enter fault analysis mode by following the procedures below.
1.
Hold down the
5
button until two beeps are heard.
The
FAULT
indicator will remain steady and the
STAY
and
AWAY
indicators will flash in unison with each other.
The illuminated
ZONE
indicators will indicate the type of system fault that has occurred. Refer to "Table 30: Fault Indicators" below for the list of different system faults that may occur.
2.
To exit fault analysis mode, press the button. The STAY and AWAY indicators will extinguish and the FAULT indicator will remain illuminated.
J"'7(/':&91%"<( @1$#%(F709<&5%&"'(
1
Low Battery
2
Date and Time
3
Sensor Watch
4
5
6
Horn Speaker Disconnected
Telephone Line Fault
E
2
Fault
7
8
Fuse Fail
Communications Failure
Table 30: Fault Indicators
C"D(3"(T9B'"D#7:67(347(!=0%7G(@1$#%(
1.
To acknowledge the system fault, press the button. The FAULT indicator will remain illuminated and the codepad will cease its once a minute beep.
Electronics Design and Manufacturing Pty Limited ISSUE140
N(
-(
Q(
*(
R(
,(
Solution 844/862/880
Installation Manual
@1$#%(F709<&5%&"'0(
\"D(V1%%7<=(
A low battery fault will register when the battery supply voltage falls below 10.5 volts or when a dynamic battery test detects a low capacity battery. This fault will clear after a successful dynamic battery test. A dynamic battery test is performed every four hours once power has been connected to the control panel and also every time the system is armed in AWAY Mode,
STAY Mode 1 or STAY Mode 2.
When reporting to the base station receiver, the control panel will report a “Battery Test
Failure” report (Contact ID Event Code 309) to indicate the low battery fault condition.
F1%7(1':(3&G7(
The date and time fault will register every time the control panel has been powered down. This type of fault will not cause the FAULT indicator on the codepad to flash unless the Auto
Arming Time on page 222 has been programmed, otherwise, the date and time fault will only be indicated when entering fault analysis mode. This fault will clear once the date and time has been programmed. Refer to Setting The Date and Time on page 114 for further information on setting the date and time.
!7'0"<(O1%94(
A sensor watch fault will register because one of the detection devices has stopped working or has failed to detect movement for the time period programmed whilst the system is disarmed.
The sensor watch fault will clear after the registered zone has been unsealed and resealed again.
To find out which zone has registered the sensor watch fault, hold down the
5
button whilst in fault analysis mode to display the zone that has registered the sensor watch fault. Refer to
Sensor Watch Time on page 220 for setting sensor watch time and Zone Options 1 on page 179 for setting zones to be monitored for sensor watch.
When reporting to the base station receiver, a “Self Test Fail” report (Contact ID Event Code
307) will be used to indicate the sensor watch fault.
C"<'(!571B7<(2"'&%"<(
A horn speaker monitor fault will register when the horn speaker becomes disconnected from the control panel. This fault will clear when the horn speaker has been reconnected. Refer to
"LOCATION 424" on page 229 to enable monitoring of the horn speaker.
37#754"'7(\&'7(@1$#%(
A telephone line fault will register when the telephone line has been disconnected from the control panel for more than 40 seconds. This fault can only occur if Option 1 in “LOCATION
176” on page 153 has been selected. The fault will clear once the telephone line has been reconnected for more than 40 seconds.
H (@1$#%(
An E
2
fault will register when the control panel detects an internal checksum error. The control panel will need to be powered down and defaulted to clear this fault.
ISSUE140 Electronics Design and Manufacturing Pty Limited
System Operations
S(
)(
75
@$07(@1&#(
This fault will occur when either the 1 Amp – 12 V accessories fuse or the 1 Amp codepad fuse has failed. After 10 seconds has expired since the fuse had failed, the control panel will automatically send a System Trouble code (Contact ID Event Code 300) to the base station receiver. After the fuse has been replaced for a period of 10 seconds, a restore report will be sent to the base station receiver.
If both the 1 Amp – 12 V accessories fuse and the 1 Amp codepad fuse have failed, only one system trouble report will be sent to the base station receiver. Only after both fuses have been replaced will any system trouble restore report will be sent to the base station receiver.
?"GG$'&91%&"'(@1&#$<7(
A communication failure fault will register if the primary telephone number and secondary telephone number for either Receiver 1 or Receiver 2 is unsuccessful in calling the receiving party.
When a communications fault occurs, to determine which receiver failed to report, hold down the
8
button for two seconds until two beeps are heard. If Receiver 1 failed to report, zone 1 will illuminate. If Receiver 2 failed to report, zone 2 will illuminate.
If the primary telephone number and secondary telephone number for Receiver 1 or Receiver 2 is set up for back to base reporting, Receiver 1 or Receiver 2 has a maximum of twelve call attempts per event to call the base station receiver (If both Receiver 1 and Receiver 2 have the primary telephone number and secondary telephone number programmed, the maximum number of calls will total 24 providing that the event is allocated to report on both receivers).
The control panel will attempt to call the base station receiver up to six times using both the primary telephone number and the secondary telephone number (Only three times if the primary telephone number is programmed). If at this stage the control panel has failed to communicate to the base station receiver, a communications fault will occur and the control panel will wait 10 minutes before attempting to report to the base station receiver for a further
6 attempts. The communication fault will reset on the next successful call attempt.
If Receiver 1 or Receiver 2 is set up for domestic reporting, the control panel will not display a fault if failed to report after the maximum of six call attempts.
If Option 1 in “LOCATION 177” on page 157 is enabled and there are no telephone numbers programmed, no fault condition will occur.
Electronics Design and Manufacturing Pty Limited ISSUE140
Solution 844/862/880
Installation Manual
T?(21&'0(@1&#$<7(
An AC mains supply failure will automatically flash the
MAINS
indicator. If the AC mains supply has been disconnected continuously for more than two minutes, the remote codepad will beep the codepad buzzer once every minute. If the control panel has been programmed to report an AC mains fail to a base station receiver,”AC Fail" report (Contact ID Event Code
301) will be transmitted.
The MAINS indicator will cease to flash as soon as the AC mains supply has been reconnected.
When the AC mains supply has been continuously connected for a period of two minutes, the codepad will cease the once a minute beep and”AC Fail” restore report will be transmitted to the base station receiver.
If Option 1 – Enable AC Fail In 1 Hour in “LOCATION 426” on page 231 has been enabled, the codepad will flash the
MAINS
indicator as soon as the AC mains supply has been disconnected and will not activate the dialler or the codepad buzzer unless the AC mains supply has been disconnected continuously for a period of 1 hour.
If Option 2 – Ignore AC Mains Fail in “LOCATION 426” on page 231 has been enabled, the codepad will not indicate when the AC mains supply has failed, but the control panel will still report if enabled an "AC Fail" report.
ISSUE140 Electronics Design and Manufacturing Pty Limited
(
L7G"%7(L1:&"(3<1'0G&%%7<(>57<1%&"'0(
Solution 844/862/880
Installation Manual
L7G"%7(L1:&"(3<1'0G&%%7<(>57<1%&"'0(
The
Solution 844/862/880
control panel has the ability to be remotely operated using hand held radio remote transmitters. There is a choice of using either a 2 channel hand held transmitter or a 4 channel hand held transmitter to operate the system.
Both the 2 channel and 4 channel hand held transmitters can remotely arm and disarm the system in AWAY Mode or STAY Mode 1 and activate remote panic alarms. However, the 4channel hand held transmitter has the added ability to operate the control panel’s programmable outputs allowing you to activate a garage door or outside lights etc.
Before any hand held radio transmitter can operate the control panel, you will need to teach the control panel the transmitters radio code. Refer to Changing Or Deleting Remote Radio User
Codes on page 79 for more information.
/':&91%&"'0(Z5"'(L7G"%7(L1:&"(3<1'0G&%%7<(>57<1%&"'0(
When using either the 2 channel or 4 channel hand held transmitters to operate the system, audible and/or visual indications can be provided via the horn speakers or the strobe. This will allow you to operate the system from outside the premises with confidence. Only the installer can program the feature of audible and/or visual indication beeps. Refer to Option 4 – Allow
Strobe Indications For Radio Arm/Disarm and Option 8 – Allow Horn Speaker Beeps For
Radio Arm/Disarm in “LOCATION 424” on page 229 for more information.
E"(>;(V7750( !=0%7G(!%1%$0(
1
System Disarmed
2
1 Two Tone
Beep
System Armed In AWAY Mode
System Armed In STAY Mode 1
Table 31: Horn Speaker Indication Beeps For Remote Operations
!%<"87(F$<1%&"'(
3 Seconds
!=0%7G(!%1%$0(
System Disarmed
6 Seconds
6 Seconds
System Armed In AWAY Mode
System Armed In STAY Mode 1
Table 32: Strobe Indications For Remote Operations
L7G"%7(L1:&"(Z07<(?":7(K<&"<&%=(\7M7#0(
The radio remote hand held transmitters may only be programmed to operate as user codes 9 –
16. Priority levels can be allocated to each radio remote hand held transmitter, allowing the transmitter to only arm the system, arm and disarm the system etc. Refer to User Code Priority on page 165 for more information.
Before any hand held radio transmitter can operate the control panel, you will need to teach the control panel the transmitters radio code. Refer to Changing Or Deleting Remote Radio User
Codes on page 79 for more information.
ISSUE140 Electronics Design and Manufacturing Pty Limited
Remote Radio Transmitter Operations 79
?41'6&'6(><(F7#7%&'6(L7G"%7(L1:&"(Z07<(?":70(
Up to eight remote radio hand held transmitters (User Codes 9 – 16) may be used to operate the system. Before the control panel will accept any of the signals from any radio remote hand held transmitter, the control panel must learn the code of the transmitter.
You may substitute the Master Code with the Installer Code if required to perform the function of changing or deleting remote radio user codes.
C"D(3"(T::(><(?41'67(T(L7G"%7(L1:&"(Z07<(?":7(
1.
Enter your followed by
1
and the button.
Three beeps will be heard and the
STAY
and
AWAY
indicators will begin to flash.
2.
Enter the button.
(9-16) that you wish to add or change followed by the
3.
Two beeps will be heard and the corresponding codepad indicators will illuminate.
Refer to "Table 33: Codepad Indicators Showing Relative Remote User Numbers" on page 80.
Now press any of the buttons on the hand held transmitter to allow the control panel to learn the hand held transmitters ID code. Two beeps will be heard and the
STAY
and
AWAY
indicators will extinguish.
If you wish to add or change any further remote radio user codes, repeat this procedure as many times as required.
+
1
+
+
+ +
When adding or changing remote radio user codes, this function will automatically terminate if a button is not pressed within sixty seconds or by pressing the button.
One long beep indicates the code entered already exists or an incorrect user number has been selected.
Radio remote user codes must be allocated to one or more areas when operating a
Solution 880 control panel that has been partitioned. Refer to User Code Allocations on page 247 for more information.
Electronics Design and Manufacturing Pty Limited ISSUE140
Solution 844/862/880
Installation Manual
C"D(3"(F7#7%7(T(L7G"%7(L1:&"(Z07<(?":7(
1.
Enter your followed by
1
and the button.
Three beeps will be heard and the
STAY
and
AWAY
indicators will begin to flash.
2.
3.
Enter the (9-16) that you wish to delete followed by the button.
Two beeps will be heard and the corresponding ZONE indicator will illuminate. Refer to “Table 33: Codepad Indicators Showing Relative Remote User Numbers” on page
80.
Press the button to delete the user code.
Two beeps will be heard and the STAY and AWAY indicators will extinguish.
If you wish to delete any further remote radio user codes, repeat this procedure as many times as required.
+
+
1
+
+ +
When deleting remote radio user codes, this function will automatically terminate if a button is not pressed within sixty seconds or by pressing the beep indicates the an incorrect user number has been selected.
button. One long
12
13
14
15
16
Z07<(
E"(
9
10
11
J"'7(N(
/':&91%"<(
#"
J"'7(-(
/':&91%"<(
J"'7(Q(
/':&91%"<(
J"'7(*(
/':&91%"<(
J"'7(R(
/':&91%"<(
#"
#"
#"
#"
#"
J"'7(,(
/':&91%"<(
J"'7(S(
/':&91%"<(
J"'7()(
/':&91%"<(
#"
#"
2T/E!(
/':&91%"<(
#"
#"
#"
#"
#"
#"
#"
Table 33: Codepad Indicators Showing Relative Remote User Numbers
ISSUE140 Electronics Design and Manufacturing Pty Limited
Remote Radio Transmitter Operations 81
-(?41''7#(L1:&"(L7G"%7(C1':(C7#:(3<1'0G&%%7<(>57<1%&"'0(
All operations via the 2 button radio remote hand held transmitter are fixed once the control panel has been taught the hand held transmitters code. Therefore, there is no programming required for each button of the transmitter.
T<G&'6(/'(TOT](2":7(
Figure 5: 2 Button
Hand Held Transmitter
(RE012)
1.
Press the BLACK button on the hand held transmitter for two seconds.
Two beeps will be heard on the remote codepad and the AWAY indicator will illuminate. Exit time will now commence.
If horn speaker indication beeps have been enabled, two beeps will be heard from the horn speaker. If the strobe indications have been enabled, the strobe will flash for 6 seconds to indicate that the system has been armed.
F&01<G&'6(@<"G(TOT](2":7(
1.
Press either the BLACK or GREEN button on the hand held transmitter for two seconds.
Two beeps will be heard on the remote codepad and the AWAY indicator will extinguish.
If the horn speaker indication beeps have been enabled, one beep will be heard from the horn speaker. If the strobe indications have been enabled, the strobe will flash for 3 seconds to indicate that the system has been disarmed.
T<G&'6(/'(!3T](2":7(N(
1.
Press GREEN button on the hand held transmitter for two seconds.
Two beeps will be heard on the remote codepad and the STAY indicator will now illuminate. Exit time will now commence.
If the horn speaker indication beeps have been enabled, one two-tone beep will be heard from the horn speaker. If the strobe indications have been enabled, the strobe will flash for 6 seconds to indicate that the system has been armed.
F&01<G&'6(@<"G(!3T](2":7(N(
1.
Press either the BLACK or GREEN button on the hand held transmitter for two seconds.
Two beeps will be heard on the remote codepad and the STAY indicator will extinguish.
If the horn speaker indication beeps have been enabled, one beep will be heard from the horn speaker. If the strobe indications have been enabled, the strobe will flash for 3 seconds to indicate that the system has been disarmed.
K1'&9(T#1<G(
1.
Press both the BLACK button and the GREEN button together for two seconds on the hand held transmitter. This will initiate an audible panic alarm that will activate the horn speaker, strobe and internal sirens.
If Option 1 – Enable Codepad Panic To Be Silent has been programmed in
“LOCATION 425” on page 230, the remote radio panic alarm will also be silent.
Electronics Design and Manufacturing Pty Limited ISSUE140
Figure 6: 4 Button
Hand Held Transmitter
(RE013)
Solution 844/862/880
Installation Manual
*(?41''7#(L1:&"(L7G"%7(C1':(C7#:(3<1'0G&%%7<(>57<1%&"'0(
All operations via the 4 channel radio remote hand held transmitter are fixed once the control panel has been taught the hand held transmitters code. Therefore, there is no programming required for each button of the transmitter. The DOOR and AUX buttons on the 4 channel radio remote hand held transmitter may be used to operate programmable outputs (e.g.: garage door or outside lights etc) on the control panel.
T<G&'6(/'(TOT](2":7(
1.
Press the AWAY button on the hand held transmitter for two seconds.
Two beeps will be heard on the remote codepad and the AWAY indicator will illuminate. Exit time will now commence.
If horn speaker indication beeps have been enabled, two beeps will be heard from the horn speaker. If the strobe indications have been enabled, the strobe will flash for 6 seconds to indicate that the system has been armed.
F&01<G&'6(@<"G(TOT](2":7(
1.
Press either the AWAY or STAY button on the hand held transmitter for two seconds.
Two beeps will be heard on the remote codepad and the AWAY indicator will extinguish.
If the horn speaker indication beeps have been enabled, one beep will be heard from the horn speaker. If the strobe indications have been enabled, the strobe will flash for 3 seconds to indicate that the system has been disarmed.
T<G&'6(/'(!3T](2":7(N(
1.
Press STAY button on the hand held transmitter for two seconds.
Two beeps will be heard on the remote codepad and the STAY indicator will now illuminate. Exit time will now commence.
If the horn speaker indication beeps have been enabled, one two-tone beep will be heard from the horn speaker. If the strobe indications have been enabled, the strobe will flash for 6 seconds to indicate that the system has been armed.
F&01<G&'6(@<"G(!3T](2":7(N(
1.
Press either the AWAY or STAY button on the hand held transmitter for two seconds.
Two beeps will be heard on the remote codepad and the STAY indicator will extinguish.
If the horn speaker indication beeps have been enabled, one beep will be heard from the horn speaker. If the strobe indications have been enabled, the strobe will flash for 3 seconds to indicate that the system has been disarmed.
K1'&9(T#1<G(
1.
Press both the AWAY button and the STAY button together for two seconds on the hand held transmitter. This will initiate an audible panic alarm that will activate the horn speaker, strobe and internal sirens.
If Option 1 – Enable Codepad Panic To Be Silent has been programmed in
“LOCATION 425” on page 230, the remote radio panic alarm will also be silent.
ISSUE140 Electronics Design and Manufacturing Pty Limited
Remote Radio Transmitter Operations 83
There are two remote outputs than can be operated from the DOOR and AUX buttons on the 4 channel hand held transmitter. These outputs can only be programmed by the installer. The output event types that can be used are listed in the table below. Refer to the section on
Programmable Outputs from page 201 for more information.
>$%5$%(HM7'%(3=57( F709<&5%&"'( K167(
2,11
Radio Control Output 1 209
2,12
2,13
2,14
Radio Control Output 2
Radio Control Output 1 – Not Armed In AWAY Mode
Radio Control Output 2 – Not Armed In AWAY Mode
209
209
209
Table 34: Remote Output Event Types
3$<'&'6(>$%5$%(N(>E(
1.
Press the DOOR button on the hand held transmitter for two seconds.
Output 1 will now turn on.
3$<'&'6(>$%5$%(N(>@@(
1.
Press the DOOR button on the hand held transmitter for two seconds.
Output 1 will now turn off.
3$<'&'6(>$%5$%(-(>E(
1.
Press the AUX button on the hand held transmitter for two seconds.
Output 2 will now turn on.
3$<'&'6(>$%5$%(-(>@@(
1.
Press the AUX button on the hand held transmitter for two seconds.
Output 2 will now turn off.
All reset times of the remote DOOR and AUX buttons are in reference to polarity 1 and 8. Reset times will vary depending on the polarity used.
Electronics Design and Manufacturing Pty Limited ISSUE140
Solution 844/862/880
Installation Manual
ISSUE140 Electronics Design and Manufacturing Pty Limited
(
!=0%7G(@$'9%&"'0(
Solution 844/862/880
Installation Manual
!=0%7G(@$'9%&"'0(
This section explains the more advanced features that are required for testing and regular maintenance of the system. Features such as Installer Code Functions, Master Code Functions and Hold Down Functions are covered in this section.
/'0%1##7<(?":7(@$'9%&"'0(
Installer Code Functions are designed to allow the installer to perform various system tests without the need to know a Master Code.
To enter the required Installer Code function, enter the followed by the required digit and the button. All available Installer Code functions are listed in “Table 35: Installer Code Functions” outlined below.
+ +
These functions can only be carried out when the system is in the disarmed state.
@$'9%&"'(
0
1
2
3
4
5
6
7
8
9
F709<&5%&"'( K167(
Reserved
Set Number Of Days Until The First Test Report
Change Domestic Telephone Numbers
87
88
Change Telco Arm/Disarm Sequence
Setting STAY Mode 2 Zones
EDMSAT - Satellite Siren Service Mode
90
95
96
Turning Telephone Monitor Mode On/Off
Walk Test Mode
97
97
Event Memory Recall Mode 98
Reserved
Table 35: Installer Code Functions
L707<M7:(
.(
ISSUE140 Electronics Design and Manufacturing Pty Limited
System Functions
N(
87
!7%(347(E$G87<(>;(F1=0(Z'%&#(347(@&<0%(370%(L75"<%(
If you require the first test to report (Contact ID Event Code 602) the day after you are installing the control panel and you have programmed the repeat interval between each test report for every 7 days, you will need to set when the first test report will occur. If the first test report is not set using this Installer Code Function, the first test report will be sent to the base station receiver in the number of days programmed in the repeat interval. Refer to
"LOCATION 360 - 366" on page 199 for setting the test report time and repeat interval.
C"D(3"(!7%(347(@&<0%(370%(L75"<%(
1.
Enter your followed by
1
and the button.
Three beeps will be heard and the
STAY
and
AWAY
indicators will begin to flash.
2.
3.
Enter the to wait (1 - 15 days) until the first test report is required.
Press the button when finished.
Two beeps will be heard and the
STAY
and
AWAY
indicators will extinguish. The system will now return to the disarmed state.
+
+
1
+
+
Each time you enter Installer's Programming Mode after you have set when the first test report will occur, the first test report time will default back to the repeat interval time between each test report as set in “LOCATION 366”.
Test reports will not report if the Subscriber ID Number is 0000. The number of days decrements by one at 2400 hours as set in "LOCATION 901 – 904" on page 225.
HI1G5#7(
If you programmed the repeat interval in the test reports for every seven days, but wish to have the first test report to begin in two days time, follow the sequence outlined below;
1234
+
1
+
+
2
+
Electronics Design and Manufacturing Pty Limited ISSUE140
ISSUE140
-(
?41'6&'6(F"G70%&9(K4"'7(E$G87<0(
When the system has been set up for domestic dialling, this function allows the installer to view and program the required telephone numbers that the system will call in the event of an alarm. For a more detailed description, refer to Domestic Dialling on page 131 for further information.
C"D(3"(?41'67(F"G70%&9(K4"'7(E$G87<0(
1.
Enter your followed by
2
and the button.
Three beeps will be heard and the
STAY
and
AWAY
indicators will begin to flash.
If there are telephone numbers already programmed, they will be displayed one digit at a time via the remote codepad indicators. Refer to "Table 37: Codepad Indicators When
Changing Telephone Numbers" on page 89 for the indicators and their meanings.
If there are no telephone numbers programmed, a further two beeps will be heard after entering this mode. These two beeps are normally heard after the last digit of the last phone number has been displayed.
2.
3.
4.
5.
Solution 844/862/880
Installation Manual
Enter all the digits for , one digit at a time. You will notice as each digit is entered, the corresponding codepad indicators will illuminate.
If there is more than one telephone number, press the button followed by the
4 button after the last digit of the telephone number. This will insert a break between the first telephone number and the second telephone number. If there is only one phone number, press the button to exit this mode.
Enter all the digits for , one digit at a time. You will notice as each digit is entered, the corresponding codepad indicators will illuminate.
After the last digit of the second telephone number, press the button to exit this mode unless a third telephone number is required. If there is a third telephone number to be programmed, press the button followed by the
4
button to insert a break between the second telephone number and the third telephone.
+
F&6&%(L7`$&<7:(
0
1
2
3
4
5
6
7
+ +
+
4
+
2
+
+
E$G87<(3"(K<"6<1G(
0
1
2
3
4
5
6
7
F&6&%(L7`$&<7:(
8
9
10
11
12
Four Second Pause
Break
15
Table 36: Domestic Dialling Digits
E$G87<(3"(K<"6<1G(
8
9
Refer To Digit
0
*
Followed By
1
*
Followed By
2
*
Followed By
3
*
Followed By
4
*
Followed By
5
Electronics Design and Manufacturing Pty Limited
8
9
11
5
6
7
(
F&6&%(
0
1
2
3
4
12
Pause
Break
15
System Functions
HI1G5#7(
89
If you wish to program two separate telephone numbers (9672 1777 and 9672 1233), follow the sequence below and replace the telephone numbers mentioned in the manual with the telephone numbers that you wish to program.
1234
+
2
+
+
96721777
+ +
4
+
96721233
+
C"D(3"(F&018#7(F"G70%&9(F&1##&'6(
If at any time you wish to cancel domestic dialling for any reason (e.g.. You are moving house and do not wish the system to continue calling your work place or mobile phone etc), you may enter your followed by
2
and the button, the button followed by the
4
and the button to disable domestic dialling.
+
2
+ + +
4
+
J"'7(N(
/':&91%"<(
#"
#"
#"
J"'7(-(
/':&91%"<(
#"
#"
J"'7(Q(
/':&91%"<(
#"
#"
J"'7(*(
/':&91%"<(
#"
#"
J"'7(R(
/':&91%"<(
#"
#"
J"'7(,(
/':&91%"<(
#"
J"'7(S(
/':&91%"<(
#"
Table 37: Codepad Indicators When Changing Telephone Numbers
J"'7()(
/':&91%"<(
#"
#"
2T/E!(
/':&91%"<(
#"
#"
#"
#"
#"
#"
Electronics Design and Manufacturing Pty Limited ISSUE140
9
11
12
6
7
8
(
F&6&%(
0
1
2
3
4
5
Pause
Break
15
Solution 844/862/880
Installation Manual
Q(
?41'67(37#9"(T<G+F&01<G(!7`$7'97(
This installer code function allows you to program the call forward sequence to automatically operate when you arm the system in AWAY Mode. This feature is only available if your telecommunication provider has the call forward option available.
When arming the system in AWAY Mode, the control panel will automatically dial the telecommunication exchange to redirect all calls to your mobile phone, pocket pager or answering service. When activated, your telephone will still allow outgoing calls to be made.
Contact your telecommunications provider for more information on call forward operations.
F&6&%(L7`$&<7:(
0
1
2
3
6
7
4
5
E$G87<(3"(K<"6<1G(
0
1
2
3
4
5
6
7
F&6&%(L7`$&<7:(
8
9
10
11
12
Four Second Pause
Break
15
Table 38: Telco Arm/Disarm Dialling Digits
E$G87<(3"(K<"6<1G(
8
9
Refer To Digit
0
*
Followed By
1
*
Followed By
2
*
Followed By
3
*
Followed By
4
*
Followed By
5
#"
#"
J"'7(N(
/':&91%"<(
#"
#"
J"'7(-(
/':&91%"<(
#"
J"'7(Q(
/':&91%"<(
#"
#"
J"'7(*(
/':&91%"<(
#"
#"
J"'7(R(
/':&91%"<(
#"
#"
J"'7(,(
/':&91%"<(
#"
Table 39: Codepad Indicators For Changing Telco Arm/Disarm Sequence
J"'7(S(
/':&91%"<(
#"
#"
#"
J"'7()(
/':&91%"<(
#"
#"
#"
#"
#"
2T/E!(
/':&91%"<(
#"
ISSUE140 Electronics Design and Manufacturing Pty Limited
System Functions 91
C"D(3"(K<"6<1G(37#9"(T<G&'6(!7`$7'97(Y(H10=(?1##(@"<D1<:(aE"(T'0D7<(>'b(
1.
2.
3.
Enter your followed by
3
and the button.
Three beeps will be heard and the STAY and AWAY indicators will begin to flash.
Press button
1
followed by the button to change the telco arming sequence.
Three beeps will be heard.
If a previous call forwarding sequence has already been programmed, the sequence will be displayed one digit at a time via the remote codepad indicators. Refer to “Table 39:
Codepad Indicators For Changing Telco Arm/Disarm Sequence” on page 90 for the indicators and their meanings.
If there is no call forward sequence programmed, a further two beeps will be heard after entering this mode. These two beeps are normally heard after the last digit of the call forward sequence has been displayed.
Enter
161
followed by the calls to followed by
you wish the control panel to divert all
2
and the button. Two beeps will be heard and the system will return to the disarmed state.
161
+
1
+
+
3
+
+
2
+
HI1G5#7(
If you wish to automatically divert all unanswered incoming calls to another telephone number
(e.g.: 9672 1777) when the system is armed in AWAY Mode, follow the example sequence below and replace the telephone number mentioned in the manual with the telephone number that you wish to divert all calls to.
+
1
+
+
1234
+
3
+
+
161
+
96721777
2
+
C"D(3"(F&018#7(347(37#9"(T<G&'6(!7`$7'97(
If at any time you wish to cancel the telco arming sequence, you may enter your then the
followed by
3
and the button, followed by
1
and the button,
button followed by the
4
and the button.
+
+
3
+ +
1
+
+
4
+
Electronics Design and Manufacturing Pty Limited ISSUE140
Solution 844/862/880
Installation Manual
C"D(3"(K<"6<1G(347(37#9"(F&01<G&'6(!7`$7'97(c(H10=(?1##(@"<D1<:(aE"(T'0D7<(>;;b(
1.
2.
3.
Enter your followed by
3
and the button.
Three beeps will be heard and the
STAY
and
AWAY
indicators will begin to flash.
Press button
2
followed by the button to change the telco disarming sequence.
Three beeps will be heard.
If a previous telco disarming sequence has already been programmed, the sequence will be displayed one digit at a time via the remote codepad indicators. Refer to “Table 39:
Codepad Indicators For Changing Telco Arm/Disarm Sequence” on page 90 for the indicators and their meanings.
If no telco disarming sequence has been programmed, a further two beeps will be heard after entering this mode. These two beeps are normally heard after the last digit of the call forward sequence has been displayed.
Enter
261 2
and the button.
Two beeps will be heard and the system will return to the disarmed state.
+
3
+
2
+
261 2
+
C"D(3"(F&018#7(347(37#9"(F&01<G&'6(!7`$7'97(
If at any time you wish to cancel the telco disarming sequence, you may enter your
followed by
3
and the button, followed by
2
and the button, then the button followed by the
4
and the button.
+
+
3
+ +
2
+
+
4
+
ISSUE140 Electronics Design and Manufacturing Pty Limited
System Functions 93
C"D(3"(K<"6<1G(37#9"(T<G&'6(!7`$7'97(Y(H10=(?1##(@"<D1<:(a/GG7:&1%7(>'b(
1.
2.
3.
Enter your followed by
3
and the button.
Three beeps will be heard and the STAY and AWAY indicators will begin to flash.
Press button
1
followed by the button to change the telco arming sequence.
Three beeps will be heard.
If a previous call forwarding sequence has already been programmed, the sequence will be displayed one digit at a time via the remote codepad indicators. Refer to “Table 39:
Codepad Indicators For Changing Telco Arm/Disarm Sequence” on page 90 for the indicators and their meanings.
If there is no call forward sequence programmed, a further two beeps will be heard after entering this mode. These two beeps are normally heard after the last digit of the call forward sequence has been displayed.
Enter
121
followed by the calls to followed by
you wish the control panel to divert all
2
and the button. Two beeps will be heard and the system will return to the disarmed state.
121
+
1
+
+
3
+
+
2
+
HI1G5#7(
If you wish to automatically divert all incoming calls to another telephone number (e.g.: 9672
1777) when the system is armed in AWAY Mode, follow the example sequence below and replace the telephone number mentioned in the manual with the telephone number that you wish to divert all calls to.
+
1
+
+
1234
+
3
+
+
121
+
96721777
2
+
C"D(3"(F&018#7(347(37#9"(T<G&'6(!7`$7'97(
If at any time you wish to cancel the telco arming sequence, you may enter your then the
followed by
3
and the button, followed by
1
and the button,
button followed by the
4
and the button.
+
+
3
+ +
1
+
+
4
+
Electronics Design and Manufacturing Pty Limited ISSUE140
Solution 844/862/880
Installation Manual
C"D(3"(K<"6<1G(347(37#9"(F&01<G&'6(!7`$7'97(c(H10=(?1##(@"<D1<:(a/GG7:&1%7(>;;b(
1.
2.
3.
Enter your followed by
3
and the button.
Three beeps will be heard and the
STAY
and
AWAY
indicators will begin to flash.
Press button
2
followed by the button to change the telco disarming sequence.
Three beeps will be heard.
If a previous telco disarming sequence has already been programmed, the sequence will be displayed one digit at a time via the remote codepad indicators. Refer to “Table 39:
Codepad Indicators For Changing Telco Arm/Disarm Sequence” on page 90 for the indicators and their meanings.
If no telco disarming sequence has been programmed, a further two beeps will be heard after entering this mode. These two beeps are normally heard after the last digit of the call forward sequence has been displayed.
Enter
221 2
and the button.
Two beeps will be heard and the system will return to the disarmed state.
+
3
+
2
+
221 2
+
C"D(3"(F&018#7(347(37#9"(F&01<G&'6(!7`$7'97(
If at any time you wish to cancel the telco disarming sequence, you may enter your
followed by
3
and the button, followed by
2
and the button, then the button followed by the
4
and the button.
+
+
3
+ +
2
+
+
4
+
ISSUE140 Electronics Design and Manufacturing Pty Limited
System Functions
*(
95
!7%%&'6(!3T](2":7(-(J"'70(
This function allows the installer to select which zones are to be automatically isolated when the system is armed in STAY Mode 2.
Every time the system is armed in STAY Mode 2, the zones selected using this function will be automatically isolated.
To arm the system in STAY Mode 2, hold down the
0
button until two beeps are heard.
Refer to Hold Down Functions on page 118 or Arming The System In STAY Mode 2 on page
67 for more information.
C"D(3"(!7%(!3T](2":7(-(J"'70(
1.
Enter your followed by
4
and the button.
Three beeps will be heard and the
STAY
indicator will begin to flash.
2.
3.
* Enter the that you wish to automatically isolate followed by the button. The corresponding ZONE indicator will begin to flash to display that you have selected the zone to be automatically isolated every time you arm the system in STAY
Mode 2.
If more than one zone is required to be automatically isolated in STAY Mode 2, repeat step 2 until all zones required have been selected.
Press the button to exit this function.
Two beeps will be heard and the system will return to the disarmed state. The zones that were selected to be automatically isolated in STAY Mode 2 and the STAY indicator will extinguish.
+
4
+
+
+ +
* As each zone has been selected to be isolated, the corresponding ZONE indicator will begin to flash. If a mistake has been made, press the zone number that was incorrectly entered followed by the button. This zone is now no longer programmed to be isolated and the ZONE indicator will extinguish.
This function will not operate on Solution 880 control panels that have been partitioned.
HI1G5#7(
If you wish to select zones 2, 5 and 6 to be automatically isolated when arming in STAY Mode
2, follow the sequence below.
1234
+
4
+
+
2
+ +
5
+ +
6
+ +
Electronics Design and Manufacturing Pty Limited ISSUE140
Solution 844/862/880
Installation Manual
C"D(3"(F&018#7(!3T](2":7(-(J"'70(
If at any time you wish to disable all zones selected to be automatically isolated for STAY
Mode 2, you may enter your followed by
4
and the button, followed by the button.
+
+
4
+
R(
!1%7##&%7(!&<7'(!7<M&97(2":7(
If an EDMSAT is connected to Output 1, this function will allow you to perform service work on the system without triggering the satellite siren. The satellite siren will return to its normal working state the next time the system is armed.
C"D(3"(H'%7<(!1%7##&%7(!&<7'(!7<M&97(2":7(
1.
Enter your
Three beeps will be heard.
followed by
5
and the button.
+
5
+
ISSUE140 Electronics Design and Manufacturing Pty Limited
System Functions
,(
S(
97
3$<'&'6(37#754"'7(2"'&%"<(2":7(>'+>;;(
Telephone monitor mode allows the remote codepad to be used for a visual representation of data transmissions between the control panel and the base station receiver. The dialling sequence is also shown in this mode.
The codepad will beep once every two seconds while telephone monitor mode is active regardless of whether the system is in Installer's Programming Mode or normal operating mode. The first five indicators are used to display the progressive steps for a transmission to the base station receiver.
J"'7(/':&91%"<(
1
2
3
4
5
None
F&1##&'6(HM7'%(
Telephone Line Seized
Dialling Phone Number
Handshake Received
Data Is Being Transmitted
Kiss-Off Received
Telephone Line Released
Table 40: Telephone Monitor Mode Indications
C"D(3"(3$<'(37#754"'7(2"'&%"<(2":7(>'(
1.
Enter your
Three beeps will be heard.
followed by
6
and the button.
C"D(3"(3$<'(37#754"'7(2"'&%"<(2":7(>;;(
1.
Enter your
Two beeps will be heard.
followed by
6
and the button.
+
6
+
O1#B(370%(2":7(
Walk test mode allows you to test detection devices to ensure that they are functioning correctly. Before activating walk test mode, isolate any zones that are not required for testing.
Refer to Isolating Zones on page 70 for further information.
C"D(3"(H'%7<(O1#B(370%(2":7(
1.
2.
Enter your followed by
7
and the button.
Three beeps will be heard and the
STAY
and
AWAY
indicators will begin to flash. The codepad will beep once every second while the system is in walk test mode.
Unseal and seal the zones to be tested.
The codepad will sound one long beep and the horn speaker will sound one short beep every time a zone is sealed or unsealed.
3.
Press the button to exit this function.
Two beeps will be heard and the
STAY
and
AWAY
indicators will extinguish. The system has now returned to the disarmed state.
+
7
+
Electronics Design and Manufacturing Pty Limited ISSUE140
)(
Solution 844/862/880
Installation Manual
HM7'%(27G"<=(L791##(2":7(
This function allows you to playback the last forty events that have occurred to the system.
The event memory recall mode reports all alarms and arming/disarming of the system in the
AWAY Mode, STAY Mode 1 and STAY Mode 2. This function helps with trouble shooting system faults. The events are displayed via the codepad indicators.
C"D(3"(H'%7<(347(HM7'%(27G"<=(L791##(2":7(
1.
Enter your followed by
8
and the button.
Three beeps will be heard. The events will be played back via the codepad indicators in reverse chronological order.
ISSUE140
+
8
+
HI1G5#7(
If the events were as follows:
HM7'%(E"(
1
2
3
4
HM7'%(F709<&5%&"'(
System Armed In AWAY Mode
Alarm In Zone 3
Alarm In Zone 4
System Disarmed
Table 41: Event Memory Recall - Example Events
HM7'%(E"(
4
3
2
1
The event memory playback will report as follows:
?":751:(/':&91%"<(
All Indicators Off Except MAINS
HM7'%(F709<&5%&"'(
System Disarmed
Zone 4 + AWAY Indicator Illuminates Alarm In Zone 4
Zone 3 + AWAY Indicator Illuminates Alarm In Zone 3
AWAY Indicator Illuminates System Armed In AWAY Mode
Table 42: Event Memory Recall - Example Event Playback
A beep and an illuminated indicator indicate each event. Resetting a 24-hour alarm in the disarmed state is indicated by one beep only. After the last event, three beeps will be heard to indicate the end of playback. The replay of event memory can be terminated at any time by
button. pressing the
If the system is armed in STAY Mode 1 or STAY Mode 2, the STAY indicator will display during the event memory playback. There is no differentiation between arming the system in STAY Mode 1 and STAY Mode 2.
If the control panel has been powered down, the memory of all events will be lost.
X(
L707<M7:(
Electronics Design and Manufacturing Pty Limited
System Functions 99
210%7<(?":7(@$'9%&"'0(
Master Code Functions are designed to allow those users that have the appropriate priority level to perform certain functions of a supervisory level. These functions can only be carried out when the system is in the disarmed state.
The default Master Code is
2580
and is known as User Code 1. It is possible for the system to have multiple Master Codes. Refer to "User Code Priority" on page 165 for more information.
To enter the required Master Code function, enter the followed by the required
digit and the button. All available Master Code functions are listed in “Table
43: Master Code Functions” outlined below.
+ +
@$'9%&"'(
0
1
2
3
4
5
6
7
8
9
F709<&5%&"'(
Arm Or Disarm Both Areas At The Same Time
Changing and Deleting User Codes/Radio Codes
Changing Domestic Phone Numbers
Changing Telco Arm/Disarm Sequence
Setting STAY Mode 2 Zones
Turning Outputs On/Off
K167(
99
100/102
104
106
111
112
Setting The Date and Time
Walk Test Mode
114
115
Event Memory Recall Mode 116
Reserved
Table 43: Master Code Functions
.(
T<G("<(F&01<G(V"%4(T<710(T%(347(!1G7(3&G7(
This Master Code function only operates on
Solution 880
systems that have been partitioned. The Master Code function allows those Master Code user codes that are allocated to both Area 1 and Area 2 to arm or disarm both areas at the same time.
This allows the user to ensure that both areas will be armed or disarmed by pressing one extra button rather that entering a code twice to ensure both areas are armed or disarmed. This function can be used to arm both areas at the same time from either the CP5 Area Addressable
Codepad (CP500A) or the Master Partitioned Codepad (CP500P). Refer to Option 2 in
“LOCATION 433” on page 244 to enable this feature.
C"D(3"(T<G+F&01<G(V"%4(T<710(T%(347(!1G7(3&G7(
1.
Enter your followed by
0
and the button.
Two beeps will be heard and both areas will be armed or disarmed from AWAY Mode.
If you require both areas to be armed or disarmed in STAY Mode 1, substitute the
button with the button.
+
0
+
Electronics Design and Manufacturing Pty Limited ISSUE140
N(
Solution 844/862/880
Installation Manual
?41'6&'6(1':(F7#7%&'6(Z07<(?":70(
This function allows a Master Code holder to add/change or delete any of the system user codes. When using a
Solution 880
control panel that has been partitioned, user codes cannot be added, changed or deleted by the Master Code holder unless they (the user code) have been allocated to an area or the same area as the Master Code. Refer to User Code
Allocations on page 247 for more information
C"D(3"(T::(><(?41'67(T(Z07<(?":7(
1.
2.
Enter your followed by
1
and the button.
Three beeps will be heard and the
STAY
and
AWAY
indicators will begin to flash.
Enter the (1-8) that you wish to change followed by the button.
Two beeps will be heard and the corresponding ZONE indicator will illuminate. Refer to "Table 44: Codepad Indicators Showing Relative User Numbers" on page 101.
3.
Enter the digits required for the followed by the button.
Two beeps will be heard and the
STAY
and
AWAY
indicators will extinguish.
If you wish to change any further user codes, repeat this procedure as many times as required.
+
+
+
1
+
+ +
When adding or changing user codes, this function will automatically terminate if a button is not pressed within sixty seconds or by pressing the button. One long beep indicates the code entered already exists or an incorrect user number has been selected.
HI1G5#7(
If you require to program user code number 2 as 4627, follow the steps outlined below and remember to substitute the default Master Code (2580) with the Master Code that has been programmed.
2580
+
1
+
+
2
+
+
4627
+
ISSUE140 Electronics Design and Manufacturing Pty Limited
System Functions 101
C"D(3"(F7#7%7(T(Z07<(?":7(
1.
Enter your followed by
1
and the button.
Three beeps will be heard and the STAY and AWAY indicators will begin to flash.
2.
Enter the (1-8) that you wish to delete followed by the button.
Two beeps will be heard and the corresponding ZONE indicator will illuminate. Refer to "Table 44: Codepad Indicators Showing Relative User Numbers" on page 101.
3.
Press the button to delete the user code.
Two beeps will be heard and the STAY and AWAY indicators will extinguish.
If you wish to delete any further user codes, repeat this procedure as many times as required.
+
+
1
+
+ +
When deleting user codes, this function will automatically terminate if a button is not
button. One long beep indicates pressed within sixty seconds or by pressing the an incorrect user number has been selected.
Z07<(
E"(
1
2
3
4
5
6
7
8
J"'7(N(
/':&91%"<(
#"
J"'7(-(
/':&91%"<(
#"
J"'7(Q(
/':&91%"<(
#"
J"'7(*(
/':&91%"<(
#"
J"'7(R(
/':&91%"<(
#"
J"'7(,(
/':&91%"<(
#"
J"'7(S(
/':&91%"<(
#"
J"'7()(
/':&91%"<(
#"
Table 44: Codepad Indicators Showing Relative User Numbers
HI1G5#7(
If you wish to delete user code number 3, follow the steps outlined below and remember to substitute the default Master Code (2580) with the Master Code that has been programmed.
2580
+
1
+
+
3
+
+
Electronics Design and Manufacturing Pty Limited ISSUE140
N(
Solution 844/862/880
Installation Manual
?41'6&'6(1':(F7#7%&'6(L7G"%7(L1:&"(Z07<(?":70(
This function allows a Master Code holder to add/change or delete any of the system user codes.
C"D(3"(T::(><(?41'67(T(L7G"%7(L1:&"(Z07<(?":7(
1.
Enter your followed by
1
and the button.
Three beeps will be heard and the STAY and AWAY indicators will begin to flash.
2.
3.
Enter the (9-16) that you wish to change followed by the button.
Two beeps will be heard and the corresponding codepad indicators will illuminate.
Refer to "Table 45: Codepad Indicators Showing Relative Remote User Numbers" on page 103.
Now press any of the buttons on the hand held transmitter.
Two beeps will be heard and the
STAY
and
AWAY
indicators will extinguish.
If you wish to change any further user codes, repeat this procedure as many times as required.
+
+
+
1
+
+
When adding or changing remote radio user codes, this function will automatically terminate if a button is not pressed within sixty seconds or by pressing the button will also terminate the session at anytime. One long beep indicates the code entered already exists or an incorrect user number has been selected.
ISSUE140 Electronics Design and Manufacturing Pty Limited
System Functions 103
C"D(3"(F7#7%7(T(L7G"%7(L1:&"(Z07<(?":7(
1.
Enter your followed by
1
and the button.
Three beeps will be heard and the STAY and AWAY indicators will begin to flash.
2.
3.
Enter the (9-16) that you wish to delete followed by the button.
Two beeps will be heard and the corresponding
ZONE
indicator will illuminate. Refer to "Table 45: Codepad Indicators Showing Relative Remote User Numbers" on page
103.
Press the button to delete the user code.
Two beeps will be heard and the
STAY
and
AWAY
indicators will extinguish.
If you wish to delete any further remote radio user codes, repeat this procedure as many times as required.
+
+
1
+
+ +
When deleting remote radio user codes, this function will automatically terminate if a button is not pressed within sixty seconds or by pressing the button will also terminate the session at anytime. One long beep indicates the an incorrect user number has been selected.
Z07<(
E"(
9
10
11
12
13
14
15
16
J"'7(N(
/':&91%"<(
#"
J"'7(-(
/':&91%"<(
J"'7(Q(
/':&91%"<(
J"'7(*(
/':&91%"<(
#"
#"
#"
#"
J"'7(R(
/':&91%"<(
J"'7(,(
/':&91%"<(
J"'7(S(
/':&91%"<(
#"
#"
J"'7()(
/':&91%"<(
#"
2T/E!(
/':&91%"<(
#"
#"
#"
#"
#"
#"
#"
Table 45: Codepad Indicators Showing Relative Remote User Numbers
Electronics Design and Manufacturing Pty Limited ISSUE140
ISSUE140
-(
Solution 844/862/880
Installation Manual
?41'6&'6(F"G70%&9(K4"'7(E$G87<0(
When the system has been set up for domestic dialling, this function allows the Master Code holder to view and program the required telephone numbers that the system will call in the event of an alarm. For a more detailed description, refer to Domestic Dialling on page 131 for further information.
C"D(3"(?41'67(F"G70%&9(K4"'7(E$G87<0(
1.
Enter your followed by
2
and the button.
Three beeps will be heard and the
STAY
and
AWAY
indicators will begin to flash.
If there are telephone numbers already programmed, they will be displayed one digit at a time via the remote codepad indicators. Refer to "Table 47: Codepad Indicators When
Changing Domestic Telephone Numbers" on page 105 for the indicators and their meanings.
If there are no telephone numbers programmed, a further two beeps will be heard after entering this mode. These two beeps are normally heard after the last digit of the last phone number has been displayed.
2.
3.
Enter all the digits for , one digit at a time. You will notice as each digit is entered, the corresponding codepad indicators will illuminate.
If there is more than one telephone number, press the button followed by the
4 button after the last digit of the telephone number. This will insert a break between the first telephone number and the second telephone number. If there is only one phone number, press the button to exit this mode.
4.
5.
Enter all the digits for , one digit at a time. You will notice as each digit is entered, the corresponding codepad indicators will illuminate.
After the last digit of the second telephone number, press the button to exit this mode unless a third telephone number is required. If there is a third telephone number to be programmed, press the button followed by the
4
button to insert a break between the second telephone number and the third telephone.
+
F&6&%(L7`$&<7:(
0
1
2
3
4
5
6
7
+
2
+
+
4
+ + +
E$G87<(3"(K<"6<1G(
0
1
2
3
4
5
6
7
F&6&%(L7`$&<7:(
8
9
*
#
Four Second Pause
Break
Table 46: Domestic Dialling Digits
E$G87<(3"(K<"6<1G(
8
9
*
Followed By
1
*
Followed By
2
*
Followed By
3
*
Followed By
4
Electronics Design and Manufacturing Pty Limited
4
5
6
7
8
(
F&6&%(
0
1
2
3
9
*
#
Pause
Break
System Functions
HI1G5#7(
105
If you wish to program two separate telephone numbers (9672 1777 and 9672 1233), follow the sequence below and replace the telephone numbers mentioned in the manual with the telephone numbers that you wish to program. Remember to substitute the default Master Code
(2580) with the Master Code that has been programmed.
2580
+
2
+
+
96721777
+ +
4
+
96721233
+
C"D(3"(F&018#7(F"G70%&9(F&1##&'6(
If at any time you wish to cancel domestic dialling for any reason (e.g.. You are moving house and do not wish the system to continue calling your work place or mobile phone etc), you may enter your followed by
2
and the button, the button followed by the
4
and the button to disable domestic dialling.
+
2
+ + +
4
+
J"'7(N(
/':&91%"<(
#"
#"
#"
J"'7(-(
/':&91%"<(
#"
#"
J"'7(Q(
/':&91%"<(
#"
#"
J"'7(*(
/':&91%"<(
#"
#"
J"'7(R(
/':&91%"<(
#"
J"'7(,(
/':&91%"<(
#"
Table 47: Codepad Indicators When Changing Domestic Telephone Numbers
J"'7(S(
/':&91%"<(
#"
J"'7()(
/':&91%"<(
#"
#"
2T/E!(
/':&91%"<(
#"
#"
#"
#"
#"
Electronics Design and Manufacturing Pty Limited ISSUE140
Q(
Solution 844/862/880
Installation Manual
?41'67(37#9"(T<G+F&01<G(!7`$7'97(
This Master Code Function allows you to program the call forward sequence to automatically operate when you arm the system in AWAY Mode. This feature is only available if your telecommunication provider has the call forward option available.
When arming the system in AWAY Mode, the control panel will automatically dial the telecommunication exchange to redirect all calls to your mobile phone, pocket pager or answering service. When activated, your telephone will not ring but outgoing calls may still be made.
Contact your telecommunications provider for more information on call forward operations.
8
9
11
12
Pause
Break
15
(
F&6&%(
0
1
2
3
4
5
6
7
F&6&%(L7`$&<7:(
0
1
2
3
4
5
6
7
E$G87<(3"(K<"6<1G(
0
1
2
3
4
5
6
7
F&6&%(L7`$&<7:(
8
9
10
11
12
Four Second Pause
Break
15
Table 48: Telco Arm/Disarm Dialling Digits
E$G87<(3"(K<"6<1G(
8
9
Refer To Digit
0
*
Followed By
1
*
Followed By
2
*
Followed By
3
*
Followed By
4
*
Followed By
5
J"'7(N(
/':&91%"<(
#"
#"
#"
#"
J"'7(-(
/':&91%"<(
#"
J"'7(Q(
/':&91%"<(
#"
#"
J"'7(*(
/':&91%"<(
#"
#"
J"'7(R(
/':&91%"<(
#"
#"
J"'7(,(
/':&91%"<(
#"
Table 49: Codepad Indicators For Changing Telco Arm/Disarm Sequence
J"'7(S(
/':&91%"<(
#"
J"'7()(
/':&91%"<(
#"
#"
2T/E!(
/':&91%"<(
#"
#"
#"
#"
#"
#"
ISSUE140 Electronics Design and Manufacturing Pty Limited
System Functions 107
C"D(3"(K<"6<1G(37#9"(T<G&'6(!7`$7'97(Y(H10=(?1##(@"<D1<:(aE"(T'0D7<(>'b(
1.
2.
3.
Enter your followed by
3
and the button.
Three beeps will be heard and the STAY and AWAY indicators will begin to flash.
Press button
1
followed by the button to change the telco arming sequence.
Three beeps will be heard.
If a previous call forwarding sequence has already been programmed, the sequence will be displayed one digit at a time via the remote codepad indicators. Refer to “Table 49:
Codepad Indicators For Changing Telco Arm/Disarm Sequence” on page 106 for the indicators and their meanings.
If there is no call forward sequence programmed, a further two beeps will be heard after entering this mode. These two beeps are normally heard after the last digit of the call forward sequence has been displayed.
Enter
161
followed by the calls to followed by
you wish the control panel to divert all
2
and the button. Two beeps will be heard and the system will return to the disarmed state.
161
+
1
+
+
3
+
+
2
+
HI1G5#7(
If you wish to automatically divert all unanswered incoming calls to another telephone number
(e.g.: 9672 1777) when the system is armed in AWAY Mode, follow the example sequence below and replace the telephone number mentioned in the manual with the telephone number that you wish to divert all calls to. Remember to substitute the default Master Code (2580) with the Master Code that has been programmed.
+
1
+
+
2580
+
3
+
161
+
96721777
+
2
+
C"D(3"(F&018#7(347(37#9"(T<G&'6(!7`$7'97(
If at any time you wish to cancel the telco arming sequence, you may enter your followed by
3
and the button, followed by
1
and the button, then the button followed by the
4
and the button.
+
+
3
+ +
1
+
+
4
+
Electronics Design and Manufacturing Pty Limited ISSUE140
Solution 844/862/880
Installation Manual
C"D(3"(K<"6<1G(347(37#9"(F&01<G&'6(!7`$7'97(c(H10=(?1##(@"<D1<:(aE"(T'0D7<(>;;b(
1.
2.
3.
Enter your followed by
3
and the button.
Three beeps will be heard and the
STAY
and
AWAY
indicators will begin to flash.
Press button
2
followed by the button to change the telco disarming sequence.
Three beeps will be heard.
If a previous telco disarming sequence has already been programmed, the sequence will be displayed one digit at a time via the remote codepad indicators. Refer to “Table 49:
Codepad Indicators For Changing Telco Arm/Disarm Sequence” on page 106 for the indicators and their meanings.
If no telco disarming sequence has been programmed, a further two beeps will be heard after entering this mode. These two beeps are normally heard after the last digit of the call forward sequence has been displayed.
Enter
261 2
and the button.
Two beeps will be heard and the system will return to the disarmed state.
+
3
+
2
+
261 2
+
C"D(3"(F&018#7(347(37#9"(F&01<G&'6(!7`$7'97(
If at any time you wish to cancel the telco disarming sequence, you may enter your
followed by
3
and the button, followed by
2
and the button, then the sequence.
button followed by the
4
and the button to disable the telco arming
+
+
3
+ +
2
+
+
4
+
ISSUE140 Electronics Design and Manufacturing Pty Limited
System Functions 109
C"D(3"(K<"6<1G(37#9"(T<G&'6(!7`$7'97(Y(H10=(?1##(@"<D1<:(a/GG7:&1%7(>'b(
1.
2.
3.
Enter your followed by
3
and the button.
Three beeps will be heard and the STAY and AWAY indicators will begin to flash.
Press button
1
followed by the button to change the telco arming sequence.
Three beeps will be heard.
If a previous call forwarding sequence has already been programmed, the sequence will be displayed one digit at a time via the remote codepad indicators. Refer to “Table 49:
Codepad Indicators For Changing Telco Arm/Disarm Sequence” on page 106 for the indicators and their meanings.
If there is no call forward sequence programmed, a further two beeps will be heard after entering this mode. These two beeps are normally heard after the last digit of the call forward sequence has been displayed.
Enter
121
followed by the calls to followed by
you wish the control panel to divert all
2
and the button. Two beeps will be heard and the system will return to the disarmed state.
121
+
1
+
+
3
+
+
2
+
HI1G5#7(
If you wish to automatically divert all incoming calls to another telephone number (e.g.: 9672
1777) when the system is armed in AWAY Mode, follow the example sequence below and replace the telephone number mentioned in the manual with the telephone number that you wish to divert all calls to. Remember to substitute the default Master Code (2580) with the
Master Code that has been programmed.
+
1
+
+
2580
+
3
+
121
+
96721777
+
2
+
C"D(3"(F&018#7(347(37#9"(T<G&'6(!7`$7'97(
If at any time you wish to cancel the telco arming sequence, you may enter your followed by
3
and the button, followed by
1
and the button, then the button followed by the
4
and the button.
+
+
3
+ +
1
+
+
4
+
Electronics Design and Manufacturing Pty Limited ISSUE140
Solution 844/862/880
Installation Manual
C"D(3"(K<"6<1G(347(37#9"(F&01<G&'6(!7`$7'97(c(H10=(?1##(@"<D1<:(a/GG7:&1%7(>;;b(
1.
2.
3.
Enter your followed by
3
and the button.
Three beeps will be heard and the
STAY
and
AWAY
indicators will begin to flash.
Press button
2
followed by the button to change the telco disarming sequence.
Three beeps will be heard.
If a previous telco disarming sequence has already been programmed, the sequence will be displayed one digit at a time via the remote codepad indicators. Refer to Refer to
“Table 49: Codepad Indicators For Changing Telco Arm/Disarm Sequence” on page
106 for the indicators and their meanings.
If no telco disarming sequence has been programmed, a further two beeps will be heard after entering this mode. These two beeps are normally heard after the last digit of the call forward sequence has been displayed.
Enter
221 2
and the button.
Two beeps will be heard and the system will return to the disarmed state.
+
3
+
2
+
221 2
+
C"D(3"(F&018#7(347(37#9"(F&01<G&'6(!7`$7'97(
If at any time you wish to cancel the telco disarming sequence, you may enter your
followed by
3
and the button, followed by
2
and the button, then the sequence.
button followed by the
4
and the button to disable the telco arming
+
+
3
+ +
2
+
+
4
+
ISSUE140 Electronics Design and Manufacturing Pty Limited
System Functions
*(
111
!7%%&'6(!3T](2":7(-(J"'70(
This function allows the Master Code Holder to select which zones are to be automatically isolated when the system is armed in STAY Mode 2. Every time the system is armed in STAY
Mode 2, the zones selected using this function will be automatically isolated.
To arm the system in STAY Mode 2, hold down the
0
button until two beeps are heard.
Refer to Hold Down Functions on page 118 or Arming The System In STAY Mode 2 on page
67 for more information.
C"D(3"(!7%(!3T](2":7(-(J"'70(
1.
Enter your followed by
4
and the button.
Three beeps will be heard and the STAY indicator will begin to flash.
2.
3.
* Enter the that you wish to automatically isolate followed by the button. The corresponding
ZONE
indicator will begin to flash to display that you have selected the zone to be automatically isolated every time you arm the system in STAY
Mode 2.
If more than one zone is required to be automatically isolated in STAY Mode 2, repeat step 2 until all zones required have been selected.
Press the button to exit this function.
Two beeps will be heard and the system will return to the disarmed state. The zones that were selected to be automatically isolated in STAY Mode 2 and the
STAY
indicator will extinguish.
+
4
+
+
+ +
* As each zone has been selected to be isolated, the corresponding ZONE indicator will begin to flash. If a mistake has been made, press the zone number that was incorrectly entered followed by the button. This zone is now no longer programmed to be isolated and the ZONE indicator will extinguish.
This function will not operate on Solution 880 control panels that have been partitioned.
HI1G5#7(
If you wish to select zones 2, 5 and 6 to be automatically isolated when arming in STAY Mode
2, follow the sequence below. Remember to substitute the default Master Code (2580) with the
Master Code that has been programmed.
2580
+
4
+
+
2
+ +
5
+ +
6
+ +
Electronics Design and Manufacturing Pty Limited ISSUE140
ISSUE140
Solution 844/862/880
Installation Manual
C"D(3"(F&018#7(!3T](2":7(-(J"'70(
If at any time you wish to disable all zones selected to be automatically isolated for STAY
Mode 2, you may enter your followed by
4
and the button, followed by the button.
+
+
4
+
R(
3$<'&'6(>$%5$%0(>'+>;;(
If an output has been programmed for remote operation, you can turn the remote output on or off using this Master Code function or remotely using the Alarm Link Software.
For this Master Code Function to operate, one or more of the following output event types need to be programmed in any of the programmable outputs.
Output Number 1 = Output Event Type – 2,8 on page 209.
Output Number 2 = Output Event Type – 2,9 on page 209.
Output Number 3 = Output Event Type – 2,10 on page 209.
C"D(3"(3$<'(T'(>$%5$%(>'(@<"G(347(L7G"%7(?":751:(
1.
Enter your followed by
5
and the button.
Three beeps will be heard and the
STAY
and
AWAY
indicators will begin to flash.
2.
Enter the required (1-3) followed by the button.
Three beeps will be heard and the output will now turn on. Repeat step 2 if more than one output is required to be turned on.
3.
Press the button again to exit this function.
Two beeps will be heard and the
STAY
and
AWAY
indicators will extinguish.
+
5
+
+ + +
HI1G5#7(
If Output 2 has been programmed as
281000
in “LOCATION 374 – 379”, the
Master Code holder may turn on this output following the steps outlined below;
2580
+
5
+
+
1
+ +
Electronics Design and Manufacturing Pty Limited
System Functions
C"D(3"(3$<'(T'(>$%5$%(>;;(@<"G(347(L7G"%7(?":751:(
1.
Enter your followed by
5
and the button.
Three beeps will be heard and the STAY and AWAY indicators will begin to flash.
2.
3.
113
Enter the required (1-3) followed by the button.
Two beeps will be heard and the output will now turn off. Repeat step 2 if more than one output is required to be turned off.
Press the button again to exit this function.
Two beeps will be heard and the STAY and AWAY indicators will extinguish.
+
+
5
+
+ +
HI1G5#7(
If Output 2 has been programmed as
281000
in “LOCATION 374 – 379”, the
Master Code holder may turn off this output following the steps outlined below;
2580
+
5
+
+
1
+ +
Electronics Design and Manufacturing Pty Limited ISSUE140
,(
Solution 844/862/880
Installation Manual
!7%%&'6(347(F1%7(1':(3&G7(
This function only needs to be used when the date and time requires to be changed or the system has been powered down.
If the date and time has not been set using this function, the date and time fault will only display when the Auto Arming Time in “LOCATION 414 - 417” on page 222 has been programmed, or when you enter Fault Analysis Mode by holding down the
5
button.
C"D(3"(!7%(347(E7D(F1%7(1':(3&G7(
1.
2.
Enter your followed by
6
and the button.
Three beeps will be heard and the
STAY
and
AWAY
indicators will begin to flash.
Enter the day, month, year, hour and minute using the (DD, MM, YY, HH, MM) format
(i.e.. DD = Day of the month, MM = Month of the year, YY = Current year, HH = Hour of the day, MM = Minute of the day).
Please note that when programming the hour of the day, you will need to use 24:00 hour format.
3.
Press the button when finished.
Two beeps will be heard and the
STAY
and
AWAY
indicators will extinguish. If a long beep is heard, an error was made when entering the date and time.
+
6
+
DD
+
MM
+
YY
+
HH
+
MM
+
HI1G5#7(
If the date and time needs to be set for the 1st January 1997 at 10:30 PM, program the date and time as follows;
2580
+
6
+
0
+
1
+
0
+
1
+
9
+
7
+
2
+
2
+
3
+
0
+
ISSUE140 Electronics Design and Manufacturing Pty Limited
System Functions
S(
115
O1#B(370%(2":7(
Walk test mode allows you to test detection devices to ensure that they are functioning correctly. Before activating walk test mode, isolate any zones that are not required for testing.
Refer to Isolating Zones on page 70 for further information.
C"D(3"(H'%7<(O1#B(370%(2":7(
1.
2.
Enter your followed by
7
and the button.
Three beeps will be heard and the STAY and AWAY indicators will begin to flash. The codepad will beep once every second while the system is in walk test mode.
Unseal and seal the zones to be tested.
The codepad will sound one long beep and the horn speaker will sound one short beep every time a zone is sealed or unsealed.
3.
Press the button to exit this function.
Two beeps will be heard and the
STAY
and
AWAY
indicators will extinguish. The system has now returned to the disarmed state.
+
7
+
Electronics Design and Manufacturing Pty Limited ISSUE140
)(
Solution 844/862/880
Installation Manual
HM7'%(27G"<=(L791##(2":7(
This function allows you to playback the last forty events that have occurred to the system.
The event memory recall mode reports all alarms and arming/disarming of the system in the
AWAY Mode, STAY Mode 1 and STAY Mode 2. This function helps with trouble shooting system faults. The events are displayed via the codepad indicators.
C"D(3"(H'%7<(347(HM7'%(27G"<=(L791##(2":7(
1.
Enter your followed by
8
and the button.
Three beeps will be heard. The events will be played back via the codepad indicators in reverse chronological order.
ISSUE140
+
8
+
HI1G5#7(
If the events were as follows:
HM7'%(E"(
1
2
3
4
HM7'%(F709<&5%&"'(
System Armed In AWAY Mode
Alarm In Zone 3
Alarm In Zone 4
System Disarmed
Table 50: Event Memory Recall - Example Events
HM7'%(E"(
4
3
2
1
The event memory playback will report as follows:
?":751:(/':&91%"<(
All Indicators Off Except MAINS
HM7'%(F709<&5%&"'(
System Disarmed
Zone 4 + AWAY Indicator Illuminates Alarm In Zone 4
Zone 3 + AWAY Indicator Illuminates Alarm In Zone 3
AWAY Indicator Illuminates System Armed In AWAY Mode
Table 51: Event Memory Recall - Example Event Playback
A beep and an illuminated codepad indicator indicate each event. Resetting a 24-hour alarm in the disarmed state is indicated by one beep only. After the last event, three beeps will be heard to indicate the end of playback. The replay of event memory can be terminated at any time by
button. pressing the
If the system is armed in STAY Mode 1 or STAY Mode 2, the STAY indicator will display during the event memory playback. There is no differentiation between arming the system in STAY Mode 1 and STAY Mode 2.
If the control panel has been powered down, the memory of all events will be lost.
X(
L707<M7:(
Electronics Design and Manufacturing Pty Limited
System Functions
Z07<(?":7(@$'9%&"'0(
@$'9%&"'(
0
+ +
F709<&5%&"'(
Arm Or Disarm Both Areas At The Same Time (CC408)
Table 52: User Code Functions
.(
117
T<G("<(F&01<G(V"%4(T<710(T%(347(!1G7(3&G7(
This user code function only operates on
Solution 880
systems that have been partitioned.
The function allows those user codes that are allocated to both Area 1 and Area 2 to arm or disarm both areas at the same time.
This allows the user to ensure that both areas will be armed or disarmed by pressing one extra button rather that entering a code twice to ensure both areas are armed or disarmed. This function can be used to arm both areas at the same time from either the CP5 Area Addressable
Codepad (CP500A) or the Master Partitioned Codepad (CP500P). Refer to Option 2 in
“LOCATION 433” on page 244 to enable this feature.
C"D(3"(T<G+F&01<G(V"%4(T<710(T%(347(!1G7(3&G7(
1.
Enter your followed by
0
and the button.
Two beeps will be heard and both areas will be armed or disarmed from AWAY Mode.
If you require both areas to be armed or disarmed in STAY Mode 1, substitute the
button with the button.
+
0
+
Electronics Design and Manufacturing Pty Limited ISSUE140
Solution 844/862/880
Installation Manual
C"#:(F"D'(@$'9%&"'0(
Hold down functions have been incorporated to allow easy activation of specific operations.
When a button is held down for two seconds, two beeps will be heard and a particular function will operate. The hold down functions available are listed below.
#
(
T<G(347(!=0%7G(/'(TOT](2":7(
Holding the
#
button down until two beeps are heard will arm the system in AWAY Mode.
Option 2 in "LOCATION 429" on page 234 will need to be enabled for this hold down function to operate.
This hold down function will not operate on
Solution 880
control panels when partitioned using the CP5 Master Partitioned codepad (CP500P). Holding the
#
button down until two beeps are heard on a CP5 Area Addressable codepad (CP500A) will arm the corresponding area in AWAY Mode.
*
(
T<G(347(!=0%7G(/'(!3T](2":7(N(
Holding the
*
button down until two beeps are heard will arm the system in STAY Mode 1.
Option 2 in "LOCATION 429" on page 234 will need to be enabled for this hold down function to operate.
If there has not been an alarm during the armed cycle, holding the
*
button down a second time will disarm the system from STAY Mode 1. If you require single button disarming from
STAY Mode 1 using this hold down function, Option 4 in "LOCATION 429" on page 234 will need to be enabled.
If an alarm has occurred or entry warning has triggered, a valid user code will need to be used to disarm the system.
Refer to Zone Options 2 on page 173 for information on programming each zone to be automatically isolated in STAY Mode 1.
This hold down function will not operate on
Solution 880
control panels when partitioned using the CP5 Master Partitioned codepad (CP500P). Holding the
*
button down until two beeps are heard on a CP5 Area Addressable codepad (CP500A) will arm the corresponding area in STAY Mode 1.
ISSUE140 Electronics Design and Manufacturing Pty Limited
119 System Functions
0
(
T<G(347(!=0%7G(/'(!3T](2":7(-(
Holding the
0
button down until two beeps are heard will arm the system in STAY Mode 2.
Option 2 in "LOCATION 429" on page 234 will need to be enabled for this function to operate.
If there has not been an alarm during the armed cycle, holding the
0
button down a second time will disarm the system from STAY Mode 2. If you require single button disarming from
STAY Mode 2 using this hold down function, Option 4 in "LOCATION 429" on page 234 will need to be enabled.
If an alarm has occurred or entry warning has been triggered, a valid user code will need to be used to disarm the system.
Refer to Setting STAY Mode 2 Zones using the Installer Code function on page 95 or Setting
STAY Mode 2 Zones using the Master Code function on page 111 for more information.
1
2
3
(
(
(
STAY Mode 2 is not available to Solution 880 control panels that have been partitioned.
C"<'(!571B7<(370%(
Holding the
1
button down until two beeps are heard will sound the horn speaker for a twosecond burst. No other sounding device will sound in this mode.
V7##(370%(
Holding the
2
button down until two beeps are heard will sound the internal screamers for a two-second burst. No other sounding device will sound in this mode.
If an EDMSAT (SS914) has been connected to the control panel, this function will test both the horn speaker and the strobe connected to the satellite siren for two seconds.
!%<"87(370%(
Holding the
3
button down will operate the strobe. No other device will operate in this mode.
If an EDMSAT (SS914) has been connected to the control panel, this function will also test the strobe on the satellite siren.
C"D(3"(3$<'(!%<"87(370%(>E(
1.
Hold down the
3
button until three beeps are heard.
The strobe will begin to flash.
C"D(3"(3$<'(!%<"87(370%(>@@(
1.
Hold down the
3
button until two beeps are heard.
The strobe will stop flashing.
Electronics Design and Manufacturing Pty Limited ISSUE140
Solution 844/862/880
Installation Manual
4
(
5
(
3$<'&'6(F1=(T#1<G(>'(1':(>;;((
Holding the
4
button down will turn day alarm on or off. If the STAY indicator is required to indicate the status of day alarm operation (enabled/disabled), refer to Option 8 in "LOCATION
428" on page 233 for further information. The STAY indicator when enabled, will flash once every 3 seconds to display when day alarm is active.
C"D(3"(3$<'(F1=(T#1<G(>E(
1.
Hold down the
4
button until three beeps are heard.
Day alarm has now been turned on.
C"D(3"(3$<'(F1=(T#1<G(>@@(
1.
Hold down the
4
button until two beeps are heard.
Day alarm has now been turned off.
@1$#%(T'1#=0&0(2":7(
There are various system faults that can be detected by the control panel. When any of these faults are present, the
FAULT
indicator will begin to flash and the codepad will beep once every minute. Refer to Fault Descriptions on page 74 for a more detailed description on each fault type.
C"D(3"(F7%7<G&'7(347(3=57(>;(@1$#%(
1.
Hold the
5
button down until two beeps are heard.
The STAY and AWAY indicators will begin to flash in unison with the FAULT indicator.
One or more
ZONE
indicators (1-8) will illuminate to indicate the type of fault that has occurred.
C"D(3"(HI&%(@1$#%(T'1#=0&0(2":7(
1.
To exit fault analysis mode, press the button.
The
STAY
and
AWAY
indicators will extinguish and return you to the disarmed state.
J"'7(/':&91%"<( @1$#%(F709<&5%&"'(
1
Low Battery
2
3
4
5
Date and Time
Sensor Watch
Horn Speaker Disconnected
Telephone Line Fault
E
2
Fault
6
7
8
Fuse Fail
Communications Failure
Table 53: Fault Indicators
ISSUE140 Electronics Design and Manufacturing Pty Limited
121 System Functions
6
(
/'&%&1%7(T(2":7G(?1##(
Holding the
6
button down until two beeps are heard will force the control panel to dial the call back telephone number programmed in "LOCATION 159 - 174" on page 151 in an attempt to connect to the installer’s remote computer.
The remote computer will be required to be running the Alarm Link Software (CC816) and will need to be set to “Waiting For An Incoming Call". If no call back telephone number has been programmed, holding down the
6
button will have no effect.
7
(
L707%(\1%94&'6(>$%5$%0(
Holding the
7
button down until two beeps are heard will reset any programmable output that has been programmed to remain on once it has been activated.
The output will need to be programmed with a latching polarity. Refer to Output Polarity on page 213 for further information.
Electronics Design and Manufacturing Pty Limited ISSUE140
Solution 844/862/880
Installation Manual
8
(
?":751:(V$dd7<(3"'7(?41'67(
Holding the
8
button down continuously will change the tone of the buzzer in the remote codepad. There are fifty different tones to choose from between 1500 Hz - 5000 Hz and they are specific to each codepad. In a multiple codepad installation, each codepad can have a different tone.
C"D(3"(?41'67(347(3"'7(>;(347(V$dd7<((
1.
2.
To change the tone of the codepad buzzer, hold the
8
button down continuously.
The tone of the buzzer will start to increase in pitch.
Release the
8
button when the desired tone has been reached.
Every time the system has been powered down, each codepad will need their individual tone reset using this function.
C"D(3"(F7%7<G&'7(347(T<71(341%(347(?":751:(V7#"'60(3"(
When using Hold Down Function 8 on
Solution 880
control panels that have been partitioned, the codepad will indicate the area that the codepad belongs to.
1.
Hold the
8
button down until two beeps are heard.
2.
A ZONE indicator will illuminate to indicate which area that the codepad belongs to when the system has been partitioned.
3.
Zone 1 = Area 1 Codepad
Zone 2 = Area 2 Codepad
Zone 7 = Master Partitioned Codepad
No
ZONE
indicator means that the codepad has incorrect settings or incorrect codepad used.
Press the button to exit this mode.
9
(
!7':(370%(L75"<%(
Holding the
9
button down until two beeps are heard will transmit a test report (Contact ID
Event Code 602) that is used to test the dialling and reporting capabilities of the system without causing the sirens to sound.
A test report will not be transmitted if the Subscriber ID Number is 0000. This feature is only applicable if the control panel has been programmed to report via the telephone.
ISSUE140 Electronics Design and Manufacturing Pty Limited
L7G"%7(!=0%7G((
>57<1%&"'0(P&1(37#754"'7(
Solution 844/862/880
Installation Manual
L7G"%7(T<G&'6(P&1(347(37#754"'7(
This feature allows you to arm your system from any remote location via the telephone line.
For obvious security reasons, the system cannot be disarmed using this method. To make use of this feature, you will require a touch tone telephone or the Phone Controller (CC911).
C"D(3"(L7G"%7#=(T<G(]"$<(!=0%7G(P&1(347(37#754"'7(
1.
2.
3.
4.
Call the telephone number that your control panel has been connected to.
When the control panel answers the incoming call, a short jingle will be heard. Hold the phone controller to the mouthpiece of the telephone and press the button on the side of the unit for 3 seconds. You can alternatively press the
*
button on the touch tone telephone for 3 seconds to arm the system.
If you hear a number of strange sounding tones when the control panel answers the incoming call, this means that the system has been programmed for remote programming functions. Simply wait for a pause in the tones and follow step 2 to remotely arm the system.
After releasing the button on the phone controller or the
*
button on the touch tone telephone, two beeps will be heard to indicate that the system has armed in AWAY
Mode.
Hang up the telephone and the system will remain armed.
If the control panel does not answer the call, this means that the system may already be armed, remote functions have not been enabled or the ring count has been set to zero. Refer to Option
2 in "LOCATION 177" on page 157 to enable remote arming via the telephone and
“LOCATION 175” on page 152 to set the number of rings before the control panel will answer.
Where both remote arming and Upload/Download via the Installer’s remote computer have been selected, the control panel will answer the call expecting the remote computer. This is easily noticed, as the modem negotiating tones will be heard rather than the remote arming jingle.
If you attempt to arm a Solution 880 control panel that has been partitioned, both areas will arm in AWAY Mode. Arming individual areas is not available using this method.
ISSUE140 Electronics Design and Manufacturing Pty Limited
T#1<G(\&'B(>57<1%&"'0(
Solution 862 - 1.00
Solution 844/862/880
Installation Manual
T#1<G(\&'B(!";%D1<7(
The
Solution 844/862/880
control panel can be remotely programmed or controlled via an IBM or compatible personal computer via the Alarm Link Software (CC816). This facility will allow you to make alterations to your customers control panel without the need to leave your office, thus improving customer service and saving you time and money. For country locations where a control panel may be situated hundreds of kilometres from your office, the
Upload/Download feature is invaluable.
When selecting the control panel type during the setup of a new customer database in the
Alarm Link Software, refer to the table below to select the software version number that corresponds to the control panel type required.
?"'%<"#(K1'7#0(!";%D1<7(P7<0&"'(
Solution 844 - 1.00
!7#79%(K1'7#(3=57(
S404_V10
S406_V10
Solution 880 - 1.00
S408_V10
Table 54: Alarm Link Panel Forms
After selecting the correct panel type when adding a new customer in the Alarm Link Software, the Subscriber ID Number and the Installer Code must match that of the control panel for synchronisation when making connection to the control panel. If these two locations do not match that of the control panel, the computer and the control panel will not synchronise.
L7G"%7(?"''79%(
The remote connect feature allows you to establish a connection through the telephone network from your IBM or compatible computer to the
Solution 844/862/880
control panel anywhere in the country where a telephone line is present. The advantages of this are very obvious and having this facility will allow you to offer faster service to your clients.
L7G"%7(?"''79%(O&%4(?$0%"G7<(?"'%<"#(
If you wish to configure the control panel so that a remote connection can only be established when the client initiates it through the remote codepad, you will need to program the following information.
"LOCATION 159 - 174" on page 151 will need to have the Call Back Telephone Number programmed and Option 1 in "LOCATION 180" on page 129/160 will need to be disabled.
The control panel has now been set so that the client has control of when a remote connection can be established.
To activate the control panel to dial the remote computer to establish a link, hold the
6
button down until two beeps are heard on the remote codepad.
ISSUE140 Electronics Design and Manufacturing Pty Limited
Alarm Link Operations 127
L7G"%7(?"''79%(O&%4"$%(?1##(V19B(P7<&;&91%&"'(
Remote connect without call back verification can be handy where you have a need to perform
Upload/Download functions from multiple locations.
There are two methods that you may program so that the call back verification is disabled. It should be noted that by using this feature you are reducing the security of the control panel.
27%4":(>'7(
Method one allows you to call the control panel from any remote location without the need of having the control panel call back to the computer to establish a link. In using method one, the customer has no access to initiate a modem call by holding down the
6
button. The following locations need to be programmed for this method to operate.
"LOCATION 159 - 174" on page 151 should be programmed as zeros. Option 1 in
"LOCATION 180" on page 129/160 will need to be enabled and Option 2 needs to be disabled.
The control panel will now allow a connection of the first call without calling the remote computer back to make contact.
27%4":(3D"(
Method two allows you to program a call back telephone number so that the customer can still initiate a modem call when required, but when calling the control panel via the computer from any remote location, the control panel does not call back the remote computer to establish a link.
"LOCATION 159 - 174" on page 151 should have the call back telephone number programmed if required. Option 1 in "LOCATION 180" on page 129/160 will need to be enabled and Option 2 needs to be disabled.
The control panel will now allow a connection of the first call without calling the remote computer back to make contact but still allow the customer to initiate a modem call by holding down the
6
button when required.
L7G"%7(?"''79%(O&%4(?1##(V19B(P7<&;&91%&"'(
Remote connect with call back verification offers the highest degree of data security by incorporating a two level security check.
The first is the Installer Code combined with the Subscriber ID Number needs to match that of the control panel. Secondly, the control panel will call back the programmed call back telephone number to establish the valid connection. The "Call Back Telephone Number" is the telephone line that the modem and computer has been connected to.
"LOCATION 159 - 174" on page 151 must be programmed with the Call Back Telephone
Number and both Option 1 and Option 2 in "LOCATION 180" on page 129/160 will need to be enabled.
Electronics Design and Manufacturing Pty Limited ISSUE140
Solution 844/862/880
Installation Manual
F&<79%(?"''79%(
The direct connect feature has been incorporated giving the installer a simple method for programming the
Solution 844/862/880
control panel at the office or on site visits using a portable computer. There is no need for telephone lines or modems that makes programming of the control panel completed easily in minutes.
All that is required is the Direct Link Cable (CC808) connected to the correct serial port on your IBM or compatible computer and the other end to the auxiliary module socket on the control panel.
When using the direct connect method of connecting to the control panel, Option 1 in
“LOCATION 180” on page 129/160 does not require to be enabled. The direct connect method of programming or operating the control panel will operate regardless of this option being set.
ISSUE140 Electronics Design and Manufacturing Pty Limited
Alarm Link Operations
LOCATION 180
N(
-(
*(
)(
>5%&"'(
1
2
4
8
129
T#1<G(\&'B(>5%&"'0(
3
F709<&5%&"'(
Enable Upload/Download Via Alarm Link
Enable Alarm Link Call Back
Terminate Alarm Link Connection On Alarm
Use External Modem Module (CC811) For Alarm Link Operations
Table 55: Alarm Link Options
H'18#7(Z5#"1:+F"D'#"1:(P&1(T#1<G(\&'B(
This option will need to be selected if you require to use the Alarm Link Software (CC816) to remotely program the control panel. The control panel will not respond to the Alarm Link
Software if this option is not selected. Refer to Alarm Link Software on page 126 for more information.
H'18#7(T#1<G(\&'B(?1##(V19B(
If this option has been selected and a call back telephone number has been programmed, the remote programming computer must be connected to the telephone line that has been programmed in the call back telephone number locations. Refer to “LOCATION 159 - 174” on page 151 for more information.
If this option is not selected, it will allow the installer to connect to their customers control panel from any remote location when attempting upload/download operations without the need to wait for the control panel to call back to the remote computer, but still allows the ability for the customer to initiate the modem call from the codepad when requested by holding down the
6
button. Refer to Alarm Link Software on page 126 for more information.
37<G&'1%7(T#1<G(\&'B(?"''79%&"'(>'(T#1<G(
If the control panel is communicating with a remote computer via Alarm Link Software
(CC816) and an alarm has registered, the Alarm Link session will be terminated and the relevant alarm message will then be transmitted to the base station receiver.
If an alarm occurs that does not need to report to the base station receiver, the session will not be terminated. If this option has not been selected and an alarm has registered, the Alarm Link software will prompt the operator with a “Terminate” or “Continue” message.
Z07(HI%7<'1#(2":7G(2":$#7(a??)NNb(@"<(T#1<G(\&'B(>57<1%&"'0(
If this option has been selected, the control panel will use the external plug-in Module (CC811) for remote programming operations via the Alarm Link Software (CC816). This option should only be enabled where the telephone line is susceptible to noise.
Electronics Design and Manufacturing Pty Limited ISSUE140
Solution 844/862/880
Installation Manual
ISSUE140 Electronics Design and Manufacturing Pty Limited
F"G70%&9(F&1##&'6(
Solution 844/862/880
Installation Manual
F"G70%&9(F&1##&'6(@"<G1%(
The locations of the primary telephone number and secondary telephone number for Receiver 1 or Receiver 2 are only used for base station reporting and pager reporting. When either
Receiver 1 or Receiver 2 is set up for domestic reporting, both the primary telephone number and the secondary telephone number will be ignored.
The domestic dialling telephone numbers are located separately in “LOCATIONS 466 – 514” making provision to store up to 48 digits. The 48 locations are used to store any number of telephone numbers and subject to the length of each telephone number, it is possible to store 4 or more different telephone numbers for domestic dialling.
If both Receiver 1 and Receiver 2 have been set up for domestic reporting format, you would still have 48 data locations and both Receiver 1 and Receiver 2 would use the same domestic telephone numbers. The ability to program separate domestic telephone numbers for Receiver
1 and Receiver 2 is not available for domestic dialling format.
Refer to Setting Up and Programming Domestic Reporting on page 133 for more information.
F"G70%&9(F&1##&'6(@$'9%&"'(
When the control panel has activated into alarm condition, it will commence dialling the first telephone number programmed. If a busy or engaged tone has been detected, the control panel will hang up and commence dialling the second telephone number (if one is programmed).
However, the first call will be counted as one unsuccessful dialling attempt. If the second telephone number is also busy or an engaged tone is detected, the control panel will hang up and commence dialling the third telephone number (if one is programmed) or return to the first telephone number.
If a busy tone is not detected, the control panel will assume that the telephone has been answered and will begin sending its transmission. The transmission sequence consists of an identification beep, followed by a siren tone and a long pause. The transmission sequence will repeat itself until the control panel receives an acknowledgment tone during the pause or the control panel automatically hangs up after a period of two minutes. The identification beep will allow the customer to verify which control panel made the call if more than one control panel is reporting to the same telephone number. The identification beep is programmed in
"LOCATION 039" of the Subscriber ID Number For Receiver 1 or “LOCATION 079” of the
Subscriber ID Number For Receiver 2.
A maximum of six calls per alarm event will be made when the control panel has been set up for "Domestic Dialling Format". This count includes any unsuccessful calls. The counter will be reset if the zone re-triggers and a further six attempts will be made. The control panel will stop dialling after six attempts or three successful calls. The control panel will also stop dialling if a valid user code has been entered at the remote codepad.
If both Receiver 1 and Receiver 2 have been programmed for domestic dialling, the maximum number of calls per alarm event is twelve.
T9B'"D#7:67(F"G70%&9(F&1##&'6(
Once the call has been received, if it is not acknowledged during any of the transmission pauses by pressing the
*
button on a touch tone telephone or by using the Phone Controller
(CC911), the control panel will continue to send its transmission for a period of 2 minutes. It will then hang up and commence dialling the next telephone number. If the call is successfully acknowledged, the control panel will hang up and no further calls will be made for that event.
ISSUE140 Electronics Design and Manufacturing Pty Limited
Domestic Dialling 133
!7%%&'6(Z5(1':(K<"6<1GG&'6(F"G70%&9(L75"<%&'6(
Programming the control panel for domestic reporting has been made extremely simple by the use of the Installer's Programming Command 965. Refer to Command 965 - Set Up Domestic
Dialling Format on page 43 for more information.
C"D(3"(!7%(Z5(347(?"'%<"#(K1'7#(@"<(F"G70%&9(F&1##&'6(
1.
2.
3.
Enter Installer's Programming Mode (EG:
1234
followed by the button).
Two beeps will be heard and the
STAY
and
AWAY
indicators will begin to flash.
Enter Command
965
followed by the button.
Two beeps will be heard. The control panel has now been set up for Domestic Dialling
Format. Refer to Command 965 - Set Up Domestic Dialling Format on page 43 for more information.
Exit Installer's Programming Mode by entering Command
960
followed by the
4.
button. Two beeps will be heard and the STAY and AWAY indicators will extinguish. The system will now return to the disarmed state.
Enter your followed by
2
and the button.
Three beeps will be heard and the STAY and AWAY indicators will begin to flash.
If there are telephone numbers programmed, they will be displayed one digit at a time via the codepad indicators.
If there are no telephone numbers programmed, a further two beeps will be heard after entering this mode. These two beeps are normally heard after the last digit of the last phone number has been displayed.
5.
6.
Enter all the digits for , one digit at a time. You will notice as each digit is entered, the corresponding codepad indicators will illuminate.
If there is more than one telephone number, press the button followed by the
4 button after the last digit of the telephone number. This will insert a break between the first telephone number and the second telephone number. If there is only one phone number, press the button to exit this mode.
7.
8.
Enter all the digits for , one digit at a time. You will notice as each digit is entered, the corresponding codepad indicators will illuminate.
After the last digit of the second telephone number, press the button to exit this mode unless a third telephone number is required. If there is a third telephone number to be programmed, press the button followed by the
4
button to insert a break between the second telephone number and the third telephone.
+
+
+
2
+
+
4
+ +
Electronics Design and Manufacturing Pty Limited ISSUE140
F&6&%(L7`$&<7:(
0
1
2
3
4
5
6
7
Solution 844/862/880
Installation Manual
E$G87<(3"(K<"6<1G(
0
1
2
3
4
5
6
7
F&6&%(L7`$&<7:(
8
9
*
#
Four Second Pause
Break
Table 56: Domestic Dialling Digits
E$G87<(3"(K<"6<1G(
8
9
*
Followed By
1
*
Followed By
2
*
Followed By
3
*
Followed By
4
HI1G5#7(
If you wish to program two separate telephone numbers (9672 1777 and 9672 1233), follow the sequence below and replace the telephone numbers mentioned in the manual with the telephone numbers that you wish to program.
2580
+
2
+
+
96721777
+ +
4
+
96721233
+
F&018#7(F"G70%&9(F&1##&'6(
If at any time you wish to cancel domestic dialling for any reason (e.g.. You are moving house and do not wish the system to continue calling your work place or mobile phone etc), you may enter your followed by
2
and the button, the button followed by the
4
and the button to disable domestic dialling.
+
2
+ + +
4
+
ISSUE140 Electronics Design and Manufacturing Pty Limited
(
F&1##7<(L75"<%&'6(@"<G1%0(
Solution 844/862/880
Installation Manual
3<1'0G&00&"'(@"<G1%0(
When making use of the control panel's dialling and communication features, there are a number of transmission formats available. Refer to "LOCATION 033" on page 145 to set the required transmission format for Receiver 1 and “LOCATION 073” on page 148 to set the required transmission formation for Receiver 2. The
Solution 844/862/880
control panel comes factory default to report in the Contact ID Format.
?"'%19%(/F(@"<G1%(
This format can identify hundreds of protection zones by their unique code and provides a single digit event qualifier and a three digit event code that quickly identifies the condition being reported.
!$809<&87<(
/F(E$G87<(
(
A$1#&;&7<(
HM7'%((
?":7(
_<"$5(
E$G87<(
K"&'%(/F(
E$G87<(
Four Digit
Subscriber ID
Number
Event Qualifier, Which Gives
Specific Event Information.
1 = New Event Or Opening
3 = New Restore Or Closing
Event Code
(Made Up Of 3
Hex Digits)
Table 57: Contact ID Format Breakdown
Group Number
(Made Up Of 2
Hex Digits)
Point ID Number
(Made Up Of 3
Hex Digits)
In general, Contact ID reporting format is very simple as most of the Event Codes and Point ID
Codes have been predefined. The base station software usually only has the ability to identify a zone going into alarm by its Point ID Code and usually pays little attention to the Event
Code.
Refer to "Table 58: Point ID Codes" on page 137 for further information on the
Solution
844/862/880
Point ID Codes.
ISSUE140 Electronics Design and Manufacturing Pty Limited
User Codes
1 - 16
030
031
040
041
046
045
042
044
Zone Specific
1 – 8
Zone Specific
1 - 8
Zone Specific
1 – 8
00
Dialler Reporting Formats 137
K"&'%(/F(?":70(
The table below shows the different Point ID Codes and Event Codes that are transmitted to the base station receiver when using Contact ID Reporting Format. All event codes are fixed and will always transmit the same code as there are no programming locations made available to alter these.
K"&'%(/F(
E$G87<(
Zones
1 - 8
HM7'%(
F709<&5%&"'(
Burglary Zone
HM7'%(
?":7(
130 Burglary
(
HI5#1'1%&"'(
(
K167(
174
Medical Zone 100 24 Hour Medical 174
Panic Zone 120 24 Hour Panic 174
Hold-Up Zone
Tamper Zone
Burglary Zone
Fire
Open/Close Report
AC Mains Fail
Low Battery
Codepad Duress
Codepad Panic
Codepad Fire
Codepad Medical
Code Retry Limit Exceeded
Test Report
Sensor Watch
110
401
301
309
122
137
133
121
120
110
100
421
602
307
24 Hour Hold-Up
24 Hour Tamper
24 Hour Burglary
24 Hour Fire
Opening – User #
Closing – User #
AC Power
Battery Test Failure
Duress Alarm
Panic Alarm
Fire Alarm
Medical Alarm
Access Denied
Test Report
Sensor Self Test Failure
174
163
195
196
174
174
174
192
192
193
193
197
199
190
Fuse Fail 300 System Trouble 194
Table 58: Point ID Codes
Electronics Design and Manufacturing Pty Limited ISSUE140
ISSUE140
Solution 844/862/880
Installation Manual
*e-(L75"<%&'6(@"<G1%(
The 4+2 Express Format will report a Subscriber ID Number followed by an expansion code and the reporting channel number is transmitted directly after the expansion code.
!$809<&87<(/F(E$G87<( HI51'0&"'(?":7( ?41''7#(E$G87<(
SSSS A CH
Table 59: Example Reporting In 4+2 Format
E7D(HM7'%(
Alarm
Trouble
Bypass
AC Fail
Low Battery
Opening Report
Closing Report
Test Report
Program Altered
Duress
*(e(-(L75"<%(
SSSS AC
H
SSSS TC
H
SSSS BC
H
SSSS EA
C
SSSS LL
B
SSSS OU
SSSS CU
SSSS T
E
O
SSSS P0
SSSS DD
0
HM7'%(
Alarm Restore
Trouble Restore
*(e(-(L75"<%(
SSSS R C
H
SSSS TR C
H
Bypass Restore
AC Fail Restore
SSSS B
R
C
H
SSSS E
R
A
CR
Low Battery Restore SSSS L
BR
L
B
Table 60: 4 + 2 Reporting Format
?":7(
SSSS
A
CH
0
T
B
E
AC
L
LB
OP
CP
U
Zero
Trouble
F709<&5%&"'(
Subscriber ID Number
Alarm
Channel Number
Bypass
AC Fail Code 1 st
Open
Close
User Number
Digit
AC Fail Code 2 nd
Digit
Low Battery Code 1 st
Digit
Low Battery Code 2 nd
Digit
?":7(
R
TR
BR
ER
ACR
LR
LBR
D
D0
P
PCH
TP
F709<&5%&"'(
Alarm Restore Code
Trouble Restore Code
Bypass Restore Code
AC Fail Restore Code 1 st
Digit
AC Fail Restore Code 2 nd
Digit
Low Battery Restore Code 1 st
Digit
Low Battery Restore Code 2 nd
Digit
Duress Code 1 st
Digit
Duress Code 2 nd
Digit
Panic Code 1 st
Digit
Panic Code 2 nd
Digit
Test Code
Table 61: 4 + 2 Transmission Code Descriptions
Electronics Design and Manufacturing Pty Limited
Dialler Reporting Formats 139
V10&9(K167<(L75"<%&'6(@"<G1%(
Basic Pager Format requires some interpretation of the numbers that appear on the display, however, it is possible to differentiate between 1000 different control panels when a number of control panels are reporting to the one pager.
C"D(3"(!7%$5(L797&M7<(N(@"<(V10&9(K167<(L75"<%&'6(
1.
"LOCATION 000 - 015" on page 143 requires the Basic Pager's access telephone number programmed.
2.
“LOCATION 034 – 039” on page 145 requires a Subscriber ID Number programmed.
3.
"LOCATION 032" on page 144 requires "Option 5 - Pager Handshake" to be selected.
4.
"LOCATION 033" on page 145 requires "Option 5 - Basic Pager Format" to be selected.
C"D(3"(!7%$5(L797&M7<(-(@"<(V10&9(K167<(L75"<%&'6(
1.
"LOCATION 040 - 055" on page 146 requires the Basic Pager's access telephone number programmed.
2.
3.
4.
“LOCATION 074 – 079” on page 148 requires a Subscriber ID Number programmed.
"LOCATION 072" on page 147 requires "Option 5 - Pager Handshake" to be selected.
"LOCATION 073" on page 148 requires "Option 5 - Basic Pager Format" to be selected.
Figure 7: Basic Pager Display
The example in "Figure 7: Basic Pager Display" shows that the transmission has come from
Subscriber ID Number 678 and that Zone 2 is in alarm, Zone 3 has been manually isolated, the system is armed, the panic zone is normal, the AC is connected and there is no fault condition.
Electronics Design and Manufacturing Pty Limited ISSUE140
Solution 844/862/880
Installation Manual
V10&9(K167<(F&05#1=(/';"<G1%&"'(
!$809<&87<(/F(E$G87<(
This is the identification number of the control panel and is programmed in “LOCATION 034
– 039” on page 145 for Receiver 1 and “LOCATION 074 – 079” on page 148 for Receiver 2.
The pocket pager will only display the last three digits of the Subscriber ID Number.
J"'7(!%1%$0(
The zone status display shows you the status of each zone (1 - 8) of the control panel. The following table below describes what each number means when displayed on the zone status display of the pocket pager.
E$G87<((
F&05#1=7:(
J"'7(F709<&5%&"'(
0
Zone Normal
This indicates that the corresponding zone is in the sealed state.
1
2
3
Alarm
This indicates that the corresponding zone is unsealed and in alarm condition.
Zone Bypassed
This indicates that a system operator has manually isolated the corresponding zone. Refer to Isolating Zones on page 70 for information on how to manually isolate a zone(s) prior to arming the system. Refer to
Zone Status – Bypass Reports on page 188 for more information.
Zone Trouble (Software Version 1.02)
This indicates that a zone was left unsealed after the end of exit time.
Refer to Zone Status – Trouble Reports on page 189 for more information.
Table 62: Zone Status Display Descriptions
!=0%7G(!%1%$0(
The system status information is divided up into 4 digits. The first digit of the system status display indicates whether the system is armed or disarmed (8 = Disarmed / 9 = Armed).
The second digit on the system status display indicates which codepad alarm was triggered by the operator (0 = No Codepad Alarm / 1 = Codepad Panic or Duress / 2 = Codepad Fire Alarm
/ 3 = Codepad Medical Alarm). Refer to Figure 4: CP5 LED Codepad Showing Audible Alarm
Buttons on page 69 for more information.
The third digit on the system status display indicates when the AC mains supply has failed (0 =
AC mains supply is normal / 1 = AC mains supply has failed or disconnected).
The fourth digit on the system status display indicates when a system fault has occurred at the control panel (0 = System Normal – There is no faults / 1 = System Fault – There is a fault registered by the control panel). Refer to Fault Analysis Mode on page 73 for more information on the types of system faults that may occur.
ISSUE140 Electronics Design and Manufacturing Pty Limited
F&1##7<(/';"<G1%&"'(
Solution 844/862/880
Installation Manual
F&1##7<(/';"<G1%&"'(
This section outlines the programming information required for the
Solution
844/862/880
control panel when communicating with base station receivers. Typically these parameters specify the telephone numbers to call, the transmission formats, handshake tones and transmission speeds.
The
Solution 844/862/880
has the ability to report event information from two onboard diallers. The first dialler reports to Receiver 1 and the second dialler reports to Receiver
2. Each dialler has the ability to be programmed with two separate telephone numbers, handshake tone, reporting format type and Subscriber ID Number.
HI1G5#7(
Dialler 1 could be set up to report in Domestic Dialling Format and reports to Receiver 1.
Dialler 2 could be set up to report to a base station receiver in Contact ID Format only when
Dialler 1 was unsuccessful.
C"D(3"(K<"6<1G(T(37#754"'7(E$G87<(
When programming the telephone number, if a '0' is required, it must be programmed as a '10'.
Each location in the primary, secondary and call back telephone numbers hold one digit of the telephone number.
To tell the dialler when the end of the telephone number has been reached, a '0' must be inserted at the end of the telephone number. Therefore the dialling sequence will be terminated when a zero appears.
HI1G5#7(
To program the telephone number 9672 1055 as the Primary Telephone Number for Receiver
1, you would program the following:
LOCATION 000 - 015
96721 5500000000
.
K<"6<1GG&'6(T(@"$<(!79"':(K1$07(/'(347(37#754"'7(E$G87<(
To enter a four-second pause in the dialling sequence, you would need to program the value
'13'. This may be necessary when the dialler is communicating through an old (slower) telephone exchange or where a PABX system is in place.
HI1G5#7(
To program the telephone number 02 pause 9672 1055 as the Primary Telephone Number for
Receiver 2, you would program the following:
LOCATION 040 - 055
2 96721 5500000
.
F&6&%(L7`$&<7:(
0
E$G87<(3"(K<"6<1G(
10
F&6&%(L7`$&<7:(
8
E$G87<(3"(K<"6<1G(
8
5
6
7
1
2
3
4
1
9
9
2
3
End Of Number
*
0
11
4
#
12
5
4 Second Pause
13
6
Break
14
7
Table 63: Dialling Digits
ISSUE140 Electronics Design and Manufacturing Pty Limited
Dialler Information 143
K<&G1<=(37#754"'7(E$G87<(@"<(L797&M7<(N(
0000000000000000
LOCATION 000 - 015
When the control panel needs to transmit a report, the control panel will dial this number in an attempt to contact the monitoring station or pager etc. If the call is successful, the relevant information will be transmitted and the dialler will return back to the stand-by mode.
If unsuccessful, the dialler will attempt two more times using the primary telephone number for receiver 1, after which the secondary telephone number for receiver 1 will be called three times. If the dialling sequence is still unsuccessful, the control panel will then attempt to repeat this procedure dialling the primary telephone number and the secondary telephone number for receiver 2 if programmed.
This procedure will be repeated only once again (i.e.. Maximum of 12 call attempts per alarm) after ten minutes if none of the first 6 attempts were successful if only the primary telephone number and secondary telephone number for receiver 1 has been programmed.
If the primary telephone number and secondary telephone numbers for both receiver 1 and receiver 2 have been programmed, a maximum of 24 call attempts per alarm will be made.
Contact your monitoring station or pager company for the relevant telephone numbers before programming these locations.
When Receiver 1 has been set up for domestic reporting, telephone numbers programmed into these locations will be ignored. Refer to Changing Domestic Phone
Numbers on page 88 when using the Installer Code function and Changing Domestic
Phone Numbers on page 104 when using the Master Code function.
LOCATION 016 - 031
!79"':1<=(37#754"'7(E$G87<(@"<(L797&M7<(N(
0000000000000000
Refer to the Primary Telephone Number For Receiver 1 for programming information.
When Receiver 1 has been set up for domestic reporting, telephone numbers programmed into these locations will be ignored. Refer to Changing Domestic Phone
Numbers on page 88 when using the Installer Code function and Changing Domestic
Phone Numbers on page 104 when using the Master Code function.
Electronics Design and Manufacturing Pty Limited ISSUE140
LOCATION 032
C1':041B7(3"'7(@"<(L797&M7<(N(
1
This location sets the type of handshake tone required for receiver 1 before data transmissions to the monitoring station will begin.
1.
Solution 844/862/880
Installation Manual
2.
3.
4.
HI LO Handshake Tone is required when the control panel requires to communicate in
Contact ID Format or High Speed DTMF.
1400 Hz Handshake Tone is required when the control panel requires to communicate in Ademco Lo Speed Format or Domestic Dialling Format.
Reserved.
No Handshake Tone is not recommended.
5.
Pager Handshake Tone is required when the control panel needs to communicate in
Basic Pager Format.
>5%&"'(
1
2
3
C1':041B7(3"'7(
HI LO Handshake
(Contact ID Format)
1400 Hz Lo Speed
(Ademco Tx At 1900Hz)
2300 Hz (Low Speed Sescoa)
>5%&"'(
4
5
C1':041B7(3"'7(
No Handshake
Pager Handshake
Table 64: Handshake Tones For Receiver 1
ISSUE140 Electronics Design and Manufacturing Pty Limited
Dialler Information 145
3<1'0G&00&"'(@"<G1%(@"<(L797&M7<(N(
1
LOCATION 033
Enter the desired transmission format here. This location selects the data format that will be transmitted to the base station receiver. This location also allows you to configure the control panel for domestic or basic pager formats.
>5%&"'(
1
2
3
3<1'0G&00&"'(@"<G1%(
Contact ID
4 + 2 Express
FSK (300 Baud) BELL
>5%&"'(
4
5
3<1'0G&00&"'(@"<G1%(
Domestic
Basic Pager
Table 65: Transmission Formats For Receiver 1
!$809<&87<(/F(E$G87<(@"<(L797&M7<(N(
000000
LOCATION 034 – 039
This number is transmitted to identify the calling control panel. Enter the desired Subscriber
ID Number in the six locations provided.
For Basic Pager Format, “LOCATION 034 – 036” will be ignored and the first digit of the
Subscriber ID Number required must start in “LOCATION 037”.
When using Domestic Dialling Format, the number of identification beeps will be the number that is programmed in “LOCATION 039”. This gives the ability to identify between 15 different control panels calling the same telephone number.
HI1G5#7(
If you wish to program the Subscriber ID Number as 4729, you would program the six locations as follows:
004729
Electronics Design and Manufacturing Pty Limited ISSUE140
Solution 844/862/880
Installation Manual
K<&G1<=(37#754"'7(E$G87<(@"<(L797&M7<(-(
0000000000000000
LOCATION 040 - 055
When the control panel needs to transmit a report, the control panel will dial this number in an attempt to contact the monitoring station or pager etc. If the call is successful, the relevant information will be transmitted and the dialler will return back to the stand-by mode.
If unsuccessful, the dialler will attempt two more times using the primary telephone number for receiver 1, after which the secondary telephone number for receiver 1 will be called three times. If the dialling sequence is still unsuccessful, the control panel will then attempt to repeat this procedure dialling the primary telephone number and the secondary telephone number for receiver 2 if programmed.
This procedure will be repeated only once again (i.e.. Maximum of 12 call attempts per alarm) after ten minutes if none of the first 6 attempts were successful if only the primary telephone number and secondary telephone number for receiver 1 has been programmed.
If the primary telephone number and secondary telephone numbers for both receiver 1 and receiver 2 have been programmed, a maximum of 24 call attempts per alarm will be made.
Contact your monitoring station or pager company for the relevant telephone numbers before programming these locations.
When Receiver 2 has been set up for domestic reporting, telephone numbers programmed into these locations will be ignored. Refer to Changing Domestic Phone
Numbers on page 88 when using the Installer Code function and Changing Domestic
Phone Numbers on page 104 when using the Master Code function.
!79"':1<=(37#754"'7(E$G87<(@"<(L797&M7<(-(
0000000000000000
LOCATION 056 - 071
Refer to the Primary Telephone Number For Receiver 2 on page 146 for more information.
When Receiver 2 has been set up for domestic reporting, telephone numbers programmed into these locations will be ignored. Refer to Changing Domestic Phone
Numbers on page 88 when using the Installer Code function and Changing Domestic
Phone Numbers on page 104 when using the Master Code function.
ISSUE140 Electronics Design and Manufacturing Pty Limited
Dialler Information
LOCATION 072
147
C1':041B7(3"'7(@"<(L797&M7<(-(
1
This location sets the type of handshake tone required for Receiver 2 before data transmissions to the monitoring station will begin.
1.
2.
3.
4.
5.
HI LO Handshake Tone is required when the control panel requires to communicate in
Contact ID Format or High Speed DTMF.
1400 Hz Handshake Tone is required when the control panel requires to communicate in Ademco Lo Speed Format or Domestic Dialling Format.
Reserved.
No Handshake Tone is not recommended.
Pager Handshake Tone is required when the control panel needs to communicate in
Basic Pager Format.
>5%&"'(
1
2
3
C1':041B7(3"'7(
HI LO Handshake
(Contact ID Format)
1400 Hz Lo Speed
(Ademco Tx At 1900Hz)
2300 Hz (Low Speed Sescoa)
>5%&"'(
4
5
C1':041B7(3"'7(
No Handshake
Pager Handshake
Table 66: Handshake Tones For Receiver 2
Electronics Design and Manufacturing Pty Limited ISSUE140
Solution 844/862/880
Installation Manual
LOCATION 073
3<1'0G&00&"'(@"<G1%(@"<(L797&M7<(-(
1
Enter the desired transmission format here. This location selects the data format that will be transmitted to the base station receiver. This location also allows you to configure the control panel for domestic or basic pager formats.
>5%&"'(
1
2
3
3<1'0G&00&"'(@"<G1%(
Contact ID
4 + 2 Express
FSK (300 Baud) BELL
>5%&"'(
4
5
3<1'0G&00&"'(@"<G1%(
Domestic
Basic Pager
Table 67: Transmission Formats For Receiver 2
LOCATION 074 – 079
!$809<&87<(/F(E$G87<(@"<(L797&M7<(-(
000000
This number is transmitted to identify the calling control panel. Enter the desired Subscriber
ID Number in the six locations provided.
For Basic Pager Format, “LOCATION 074 – 076” will be ignored and the first digit of the
Subscriber ID Number required must start in “LOCATION 077”.
When using Domestic Dialling Format, the number of identification beeps will be the number that is programmed in “LOCATION 079”. This gives the ability to identify between 15 different control panels calling the same telephone number.
HI1G5#7(
If you wish to program the Subscriber ID Number as 4729, you would program the six locations as follows:
004729
ISSUE140 Electronics Design and Manufacturing Pty Limited
Dialler Information 149
F&1##&'6(@"<G1%(
1
LOCATION 080
The method for dialling telephone numbers is entered here. Options 3 and 6 will alternate the dialling sequence between DTMF and Decadic if the call to the base station receiver was unsuccessful. Caution should be exercised when selecting the dialling method.
Only use the Australian method if the control panel is to be connected to the Australian
Telecommunications Network. The International DTMF dialling option should only be used in those countries that allow both the caller and the receiver to terminate the phone call. Using the incorrect format will disable EDM's patent Telephone Anti-Jamming feature.
>5%&"'(
1
2
3
F&1##&'6(@"<G1%(
Australian DTMF
(5 Digits/Second)
Australian Decadic
Alternating DTMF
& Australian Decadic
>5%&"'(
4
5
6
F&1##&'6(@"<G1%(
International DTMF
(Touch Tone)
Reversed Decadic
(10 Minus 1)
Alternate DTMF
& Reversed Decadic
Table 68: Dialling Formats
The alternating sequence is as follows; DTMF - Decadic - DTMF - Decadic - DTMF -
Decadic
L707<M7:(
LOCATION 081 – 112
00000000000000000000000000000000
Electronics Design and Manufacturing Pty Limited ISSUE140
Solution 844/862/880
Installation Manual
37#9"(T<G&'6(!7`$7'97(
LOCATION 113 – 142
000000000000000000000000000000
These locations allow you to automatically activate call diversion on your telephone when you arm the system in AWAY Mode.
Upon activating the Telco Arming Sequence when arming the system in AWAY Mode, the control panel will redirect all calls to your mobile phone, pocket pager or answering service.
Contact your telecommunications provider for more information on Call Forward operations.
F&6&%(L7`$&<7:( E$G87<(3"(K<"6<1G( F&6&%(L7`$&<7:( E$G87<(3"(K<"6<1G(
0
10
8
8
1
1
9
9
2
3
2
3
10
*
10
11
4
4
#
12
5
5
Four Second Pause
13
6
6
Break
14
7
7
15
15
Table 69: Telco Arm/Disarm Dialling Digits
37#9"(T<G&'6(c(?1##(@"<D1<:(/GG7:&1%7(>'(
To turn Call Forward Immediate On:
*21
(Phone Number you want calls to go to)
#
HI1G5#7(
If you wish to immediately forward all incoming calls to the telephone number 96721055 upon arming the system in AWAY Mode, you would program the following:
2196721 55 00000000000000
0000
37#9"(T<G&'6(c(?1##(@"<D1<:(E"(T'0D7<(>'(
To turn Call Forward No Answer On:
*61
(Phone Number you want calls to go to)
#
HI1G5#7(
If you wish to forward all incoming calls to the telephone number 96721055 upon arming the system in AWAY Mode when there is no answer, you would program the following:
6196721 55 00000000000000
0000
ISSUE140 Electronics Design and Manufacturing Pty Limited
Dialler Information 151
37#9"(F&01<G&'6(!7`$7'97(
0000000000000000
LOCATION 143 – 158
These locations allow you to automatically deactivate call diversion on your telephone when you disarm the system from AWAY Mode.
F&6&%(L7`$&<7:(
4
5
6
7
0
1
2
3
E$G87<(3"(K<"6<1G(
10
1
2
3
4
5
6
7
F&6&%(L7`$&<7:(
8
9
10
*
#
Four Second Pause
Break
15
Table 70: Telco Arm/Disarm Dialling Digits
E$G87<(3"(K<"6<1G(
8
9
10
11
12
13
14
15
37#9"(T<G&'6(c(?1##(@"<D1<:(/GG7:&1%7(>;;(
To turn Call Forward Immediate Off:
#21#
HI1G5#7(
If you wish to disable the Telco Arming – Call Forward Immediate upon disarming the system from AWAY Mode, you would program the following:
21 000000000000
37#9"(T<G&'6(c(?1##(@"<D1<:(E"(T'0D7<(>;;(
To turn Call Forward No Answer Off:
#61#
HI1G5#7(
If you wish to disable the Telco Arming – Call Forward No Answer upon disarming the system from AWAY Mode, you would program the following:
61 000000000000
LOCATION 159 - 174
?1##(V19B(37#754"'7(E$G87<(
0000000000000000
This location contains the telephone number that will be called when Upload/Download is requested or the number
6
button is held down to initiate a modem call from the control panel to establish a communications link with the remote computer. The computer must be running the Alarm Link Software (CC816) and will need to be set to "Waiting For An Incoming Call".
The Call Back Telephone Number is also required to be programmed if Remote Connect With
Call Back Verification on page 127 is required.
Refer to the section - Alarm Link Operations beginning on page 125 for more information.
Electronics Design and Manufacturing Pty Limited ISSUE140
LOCATION 175
Solution 844/862/880
Installation Manual
L&'6(?"$'%(
8
This location sets the number of rings before the control panel will answer an incoming call.
This should be set at an acceptable level bearing in mind that one ring = "Ring, Ring - Ring,
Ring" and that a ring count of 10 represents approximately 60 seconds. This location only has an effect if remote arming and/or remote Upload/Download via Alarm Link Software has been enabled. If this location is programmed as 'zero', then the answering of incoming calls will be totally disabled irrespective of any programmed options.
T'0D7<&'6(2194&'7(V=5100(
Answering machine bypass has been incorporated so that it is possible to make a connection with the control panel for remote arming or Upload/Download when there is an answering machine or facsimile machine on the same telephone line. There are two different methods of using answering machine bypass as explained below. The secondary method should only be used when there is a large amount of traffic on the line (e.g.. A home office). It will reduce the chance of the control panel incorrectly answering incoming calls.
1.
2.
Programming the ring count as 15 will enable "Answering Machine Bypass" in the primary mode. When calling the control panel, let the phone ring for no more than 4 rings and then hang up. If you call again within 45 seconds, the control panel will answer the call on the first ring and the connection will be established. This will prevent the answering machine or facsimile from answering the call. Refer to Option 2 in "LOCATION 177" on page 157 if you wish to enable Answering Machine Bypass
Only When System Is Armed.
Programming a 14 as the ring count will enable "Answering Machine Bypass" in the secondary mode. In this mode, when calling the control panel, allow the phone to ring for no more than 2 rings and then hang up. Wait a minimum of 8 seconds before calling the control panel again. The control panel will now answer on the first ring. If you do not wait the 8 seconds, the control panel will not answer the call. Refer to Option 2 in
"LOCATION 177" on page 157 if you wish to enable Answering Machine Bypass Only
When System Is Armed.
You should set the ring count on the answering machine or facsimile machine to be higher than two rings. Four or six rings would be preferred.
Programming a zero into this location will disable the control panel from answering an incoming call.
ISSUE140 Electronics Design and Manufacturing Pty Limited
Dialler Information
LOCATION 176
N(
-(
*(
153
37#754"'7(\&'7(@1$#%(>5%&"'0(
0
When programming this location, you will notice that there are four options per location. If you require options 1, 2, 4 or all of these options, only one number needs to be programmed.
This number is calculated by adding the option bit numbers together. Program a 7 if you require options 1, 2 and 4 simultaneously (i.e.. 1 + 2 + 4 = 7).
>5%&"'(
1
2
4
8
F709<&5%&"'(
Operate The FAULT Indicator When Telephone Line Fails
Sound Speaker, Bell and Strobe When System Is Armed
Sound Speaker, Bell and Strobe When System Is Disarmed
Reserved
Table 71: Telephone Line Fault Options
The
Solution 844/862/880
has the ability to monitor the telephone line. If the telephone line has been cut or disconnected for more than forty seconds, the control panel will recognise this and the
FAULT
indicator will illuminate on the codepad. The
FAULT
indicator will extinguish once the telephone line has been restored for more than forty seconds.
Option 2 and 4 will not operate unless option 1 has been enabled.
>57<1%7(347(@TZ\3(/':&91%"<(O47'(37#754"'7(\&'7(@1�(
The
FAULT
indicator will flash and the codepad buzzer will beep once every minute if the control panel detects that the telephone line has been disconnected. Refer to Fault Descriptions on page 74 for more information.
!"$':(!571B7<f(V7##(1':(!%<"87(O47'(347(!=0%7G(/0(T<G7:(
Option 1 in this location will also need to be selected for this option to operate. If the control panel detects that the telephone line has been disconnected when the system is armed in
AWAY Mode, STAY Mode 1 or STAY Mode 2, the horn speaker, bell and strobe outputs will operate.
!"$':(!571B7<f(V7##(1':(!%<"87(O47'(347(!=0%7G(/0(F&01<G7:(
Option 1 in this location will also need to be selected for this option to operate. If the control panel detects that the telephone line has been disconnected when the system is disarmed, the horn speaker, bell and strobe outputs will operate.
L707<M7:(
)(
If Options 1, 2 and 4 have been added together, the horn speaker, bell, strobe and
EDMSAT outputs will operate when the system is armed or disarmed.
Electronics Design and Manufacturing Pty Limited ISSUE140
LOCATION 748 - 749
\"91%&"'(
748
749
Solution 844/862/880
Installation Manual
L&'6(V$<0%(3&G7(
46
F709<&5%&"'(
Increments Of 5 ms
Increments Of 80 ms
Table 72: Ring Burst Time Locations
(V1.07+) These locations program the ring burst time (Default = 500 ms). If the duration of the telephone ring tone is 1.5 seconds, programming the ring burst time more than the telephone ring duration (1.5 seconds); the control panel will not detect an incoming call.
Always program the ring burst time less than the duration of the ring tone.
These locations are factory set and should not be changed unless required.
ISSUE140 Electronics Design and Manufacturing Pty Limited
F&1##7<(>5%&"'0(
Solution 844/862/880
Installation Manual
K<"6<1GG&'6(>5%&"'(V&%0(
When programming these locations, you will notice that there are four options per location.
You may select one, two, three or all four of these options, however, only one number needs to be programmed. This number is calculated by adding the option bit numbers together.
HI1G5#7(
If at "LOCATION 177" you want options 1, 2 and 4, add the numbers together and the total is the number to be programmed. In this example, the number to be programmed is 7 (i.e. 1 + 2
+ 4 = 7).
>5%&"'( F709<&5%&"'(
1
Dialler Reporting Functions Allowed
2
Remote Arming Via The Telephone Allowed
4
Answering Machine Bypass Only When Armed
8
Use Bell 103 For FSK Format (Disabled = CCITT V21)
Table 73: Example - Programming Option Bits
ISSUE140 Electronics Design and Manufacturing Pty Limited
Dialler Options
LOCATION 177
N(
-(
*(
)(
>5%&"'(
1
2
4
8
157
F709<&5%&"'(
Dialler Reporting Functions Allowed
Remote Arming Via The Telephone Allowed
Answering Machine Bypass Only When Armed
Use Bell 103 For FSK Format (Disabled = CCITT V21)
Table 74: Dialler Options 1
F&1##7<(>5%&"'0(N(
9
F&1##7<(L75"<%&'6(@$'9%&"'0(T##"D7:(
If this option has been selected, the dialler will function for all operations. Upload/Download via Alarm Link Software (CC816) and telephone remote arming will remain operational regardless of this setting.
F&018#7:(g(F&018#7(T##(F&1##7<(L75"<%&'6(@$'9%&"'0(
If this option is not selected, the communication dialler will not operate. Upload/Download via
Alarm Link Software (CC816) and telephone remote arming will remain operational regardless of this setting.
L7G"%7(T<G&'6(P&1(347(37#754"'7(T##"D7:(
If this option has been selected, you can remotely arm the system via a standard telephone using the Phone Controller (CC911) or by pressing the
*
button on your touch tone telephone. Refer to Remote Arming Via The Telephone on page 124 for more information.
Forced arming is automatically assumed when this feature is being used. Refer to Zone
Options 2 on page 183 for more information on forced arming.
Whether remote functions have been enabled or disabled, this will have no effect on remote arming via the telephone. Refer to Ring Count on page 152 for programming the number of rings before the control panel will answer an incoming call.
T'0D7<&'6(2194&'7(V=5100(>'#=(O47'(T<G7:(
This option needs to be selected if the answering machine bypass feature is required to operate only when the system has been armed in AWAY Mode, STAY Mode 1 or STAY Mode 2.
When the system is disarmed, the control panel will not answer any incoming calls. This option is beneficial in high telephone traffic installations where the control panel could answer an incoming call. Refer to Ring Count on page 152 to program answering machine bypass.
Z07(V7##(N.Q(@"<(@!U(@"<G1%(aF&018#7:(g(??/33(P-Nb(
If this option is enabled, the control panel will use the transmission frequency BELL 103 at
300 baud. If this option is disabled, the control panel will use the transmission frequency
CCITT V21 at 300 baud.
Electronics Design and Manufacturing Pty Limited ISSUE140
LOCATION 178
N(
----((((
*(
)(
Solution 844/862/880
Installation Manual
F&1##7<(>5%&"'0(-(
0
>5%&"'(
1
2
4
8
F709<&5%&"'(
Open/Close Reports Only If Previous Alarm
Open/Close Reports For STAY Mode 1 and STAY Mode 2
Delay Siren Until Transmission Complete
Extend Time To Wait For Handshake From 30 To 55 Seconds
Table 75: Dialler Options 2
>57'+?#"07(L75"<%0(>'#=(/;(K<7M&"$0(T#1<G(
This option requires Open/Close reports in “LOCATION 333 - 334” to be enabled on page 191 for it to be effective.
An opening report will be transmitted to the base station receiver when the system has been disarmed after an alarm has occurred. When the system has been armed, a closing report will be transmitted. An opening or closing report will not report again until the system has registered another alarm condition.
If the system is disarmed when an alarm occurs, only a closing report will be transmitted when the system is next armed.
>57'+?#"07(L75"<%0(@"<(!3T](2":7(N(1':(!3T](2":7(-(
If open and close reports are required when the system is armed in STAY Mode 1 or STAY
Mode 2, this option will need to be selected.
This option requires Open/Close reports in “LOCATION 333 - 334” to be enabled on page 191 for it to be effective.
F7#1=(!&<7'(Z'%&#(3<1'0G&00&"'(?"G5#7%7(
If this option has been selected, the EDMSAT, horn speaker, bell and strobe outputs will not activate until the base station receiver has sent a kiss-off back to the control panel after the message has been transmitted. If multiple messages are transmitted, the sirens will activate after the last kiss-off has been sent.
However, the EDMSAT, horn speaker, bell and strobe outputs will activate as soon as a codepad panic, codepad fire and codepad medical alarms have been activated.
HI%7':(3&G7(3"(O1&%(@"<(C1':041B7(@<"G(Q.(Y(RR(!79"':0(
The control panel after dialling the monitoring station will wait approximately 30 seconds for receipt of a valid handshake tone. The handshake tone indicates to the control panel that it has reached the monitoring station and can now transmit its messages. Enabling this option will extend the wait time from 30 seconds to 55 seconds.
ISSUE140 Electronics Design and Manufacturing Pty Limited
Dialler Options
LOCATION 179
N(
-(
*(
)(
159
F&1##7<(>5%&"'0(Q(
0
>5%&"'(
1
2
4
8
F709<&5%&"'(
Set DTMF Dialling Pulses To 1 Digit/Second
Reserved
Change Decadic Dialling To 60/40
Reserved
Table 76: Dialler Options 3
!7%(F32@(F&1##&'6(K$#070(3"(N(F&6&%+!79"':(
If this option is not selected, the dialling format – Australian DTMF dials at the rate of 5 digits per second (i.e. 100 ms tone, 100 ms pause, 100 ms tone, 100 ms pause).
If this option has been selected, the dialling format – Australian DTMF dials at the rate of 1 digit per second (i.e. 500 ms tone, 500 ms pause).
L707<M7:(
?41'67(F791:&9(F&1##&'6(3"(,.+*.(
Some countries have different requirements for decadic dialling. Setting this option will change the dialling characteristics from 65/35 (Australian Standard) to 60/40. This option should only be set when the control panel is used in a country that requires decadic dialling as
60/40. This option has no effect when using DTMF tone dialling.
L707<M7:(
Electronics Design and Manufacturing Pty Limited ISSUE140
LOCATION 180
N(
-(
*(
)(
>5%&"'(
1
2
4
8
Solution 844/862/880
Installation Manual
T#1<G(\&'B(>5%&"'0(
3
F709<&5%&"'(
Upload/Download Allowed
Call Back Phone Number Required For Upload/Download
Terminate Upload/Download On Alarm
External Modem Module (CC811) Required For Upload/.Download
Table 77: Alarm Link Options
Z5#"1:+F"D'#"1:(T##"D7:(
This option will need to be selected if you require to use the Alarm Link Software (CC816) to remotely program the control panel. The control panel will not respond to the Alarm Link
Software if this option is not selected. Refer to Alarm Link Software on page 126 for more information.
?1##(V19B(K4"'7(E$G87<(L7`$&<7:(@"<(Z5#"1:+F"D'#"1:(
If this option has been selected and a call back telephone number has been programmed, the remote programming computer must be connected to the telephone line that has been programmed in the call back telephone number in “LOCATION 159 - 174” on page 151.
If this option is not selected, it will allow the installer to connect to their customers control panel from any remote location when attempting upload/download operations without the need to wait for the control panel to call back to the remote computer, but still allows the ability for the customer to initiate the modem call from the codepad when requested by holding down the
6
button. Refer to Alarm Link Software on page 126 for more information.
37<G&'1%7(Z5#"1:+F"D'#"1:(>'(T#1<G(
If the control panel is communicating with a remote computer via Alarm Link Software
(CC816) and an alarm has registered, the “Alarm Link” session will be terminated and the relevant alarm message will then be transmitted to the base station receiver.
If an alarm occurs that does not need to report to the base station receiver, the session will not be terminated. If this option has not been selected and an alarm has registered, the Alarm Link software will prompt the operator with a “Terminate” or “Continue” message.
HI%7<'1#(2":7G(2":$#7(a??)NNb(L7`$&<7:(@"<(Z5#"1:+F"D'#"1:(
If this option has been selected, the control panel will use the external plug-in Modem Module
(CC811) for remote programming operations via the Alarm Link Software (CC816). This option should only be enabled where the telephone line is susceptible to noise.
ISSUE140 Electronics Design and Manufacturing Pty Limited
Z07<(?":70(
Solution 844/862/880
Installation Manual
T99700(?":70(
This section describes the access codes that are used to assign privileges and access functions for user code holders of the system. Two types of user codes exist within the system, the
Installer Code and User Codes. Each of these codes allow specific access and operation of the varied functions of the control panel.
LOCATION 181 - 184
/'0%1##7<(?":7(
1234
This code is used to access the Installer's Programming Mode and can be between one to four digits long. However, after the control panel has been powered up, the Installer Code can disarm the system if it is the first code used. The next time the Installer Code is used, access into Installer's Programming Mode will be made.
Installer Code functions are available to allow the installer to carry out various functions during the disarmed state without the need to remember the customers Master Code. Refer to
Installer Code Functions on page 86 for more information.
Refer to Programming With The Remote Codepad on page 29 for more information on programming the system once Installer’s Programming Mode has been accessed.
ISSUE140 Electronics Design and Manufacturing Pty Limited
User Codes 163
Z07<(?":70(
LOCATION 185 - 264
The purpose of user codes is to arm and disarm the system as well as perform other specific functions as described in Master Code Functions on page 99.
User codes (1–8) can be any length between one to four digits long. Each user code may have a different priority level or multiple user codes may have the same priority level. The priority level controls the behaviour of the code, allowing it to arm only, arm and disarm or be a Master
Code holder etc. The priority level of each user code is programmed in the last location of each user code and can only be programmed by the installer. The Master Code holder does not have any ability to change the priority level of any user code.
NR( NR( NR( NR( ( .( (
Z07<(?":7( K<&"<&%=(
There are a total of 16 user codes available that can be changed or deleted at any time by a
Master Code holder, however, user codes 9 – 16 can only be remote radio user codes. Refer to
Remote Radio Transmitter Operations on page 78 for more information. Multiple Master
Codes can be programmed. Refer to Master Code Functions on page 99 for more information on adding, deleting or changing user codes.
The priority level for each user code can only be programmed or altered by the installer.
2.
3.
4.
5.
User Code 16 will report when any of the following methods for arming and disarming are used.
1.
Arm and disarm via remote radio control equipment connected to the optional Radio
Key/Keyswitch Interface (CC813).
6.
7.
Arm and disarm the system via Alarm Link Software (CC816).
Arm the system remotely over the telephone.
Single button arming in AWAY Mode, STAY Mode 1 or STAY Mode 2.
Single button disarming from STAY Mode 1 or STAY Mode 2.
Automatic arming in AWAY Mode or STAY Mode 1.
Automatic disarming from AWAY Mode or STAY Mode 1 or STAY Mode 2
Electronics Design and Manufacturing Pty Limited ISSUE140
Solution 844/862/880
Installation Manual
!"#$%&"'()**+),-(Z07<(?":70(
The
Solution 844/862
has the ability to have up to eight programmable user codes (User
Codes 1 – 8) to operate the system. Refer to System Operations on page 62 for information on the different methods of arming and disarming the system.
User codes 9 – 16 have been included to allow those systems that require radio remote control via hand held remote transmitters. Refer to Remote Radio Transmitter Operations on page 78 for information on remote operations and adding and deleting remote radio user codes.
( ( ( ( (
Z07<(?":7(N
Location 185 - 189
-( R( )( .( N.(
Z07<(?":7(-
Location 190 - 194
NR( NR( NR( NR( -(
Z07<(?":7(Q
Location 195 - 199
NR( NR( NR( NR( -(
Z07<(?":7(*
Location 200 - 204
NR( NR( NR( NR( -(
Z07<(?":7(R
Location 205 - 209
NR( NR( NR( NR( -(
Z07<(?":7(,
Location 210 - 214
NR( NR( NR( NR( -(
Z07<(?":7(S
Location 215 - 219
NR( NR( NR( NR( -(
Z07<(?":7()
Location 220 - 224
.( NR( NR( NR( Q(
(
L1:&"(?":7(X(
Location 225 - 229
NR( NR( NR( NR( -(
(
L1:&"(?":7(N.(
Location 230 - 234
NR( NR( NR( NR( -(
(
L1:&"(?":7(NN(
Location 235 - 239
NR( NR( NR( NR( -(
(
L1:&"(?":7(N-(
Location 240 - 244
NR( NR( NR( NR( -(
(
L1:&"(?":7(NQ(
Location 245 - 249
NR( NR( NR( NR( -(
(
L1:&"(?":7(N*(
Location 250 - 254
NR( NR( NR( NR( -(
(
L1:&"(?":7(NR(
Location 255 - 259
NR( NR( NR( NR( -(
(
L1:&"(?":7(N,(
Location 260 - 264
NR( NR( NR( NR( -(
(
(
( ( ( ( (
!"#$%&"'()).(Z07<(?":70(
The
Solution 880
has the ability to have up to sixteen programmable user codes (User
Codes 1 – 16). Refer to System Operations on page 62 for information on the different methods of arming and disarming the system.
However, if you wish to remotely operate the system via hand held remote transmitters, user codes 9 – 16 may be programmed as remote user codes. Refer to Remote Radio Transmitter
Operations on page 78 for information on remote operations and adding and deleting remote radio user codes.
( ( ( ( (
Z07<(?":7(N
Location 185 - 189
-( R( )( .( N.(
Z07<(?":7(-
Location 190 - 194
NR( NR( NR( NR( -(
Z07<(?":7(Q
Location 195 - 199
NR( NR( NR( NR( -(
Z07<(?":7(*
Location 200 - 204
NR( NR( NR( NR( -(
Z07<(?":7(R
Location 205 - 209
NR( NR( NR( NR( -(
Z07<(?":7(,
(
Z07<(?":7(X(
(
Z07<(?":7(N-(
(
Z07<(?":7(NR(
Location 210 - 214
NR( NR( NR( NR( -(
Location 225 - 229
NR( NR( NR( NR( -(
Location 240 - 244
NR( NR( NR( NR( -(
Location 255 - 259
NR( NR( NR( NR( -(
Z07<(?":7(S
(
Z07<(?":7(N.(
(
Z07<(?":7(NQ(
(
Z07<(?":7(N,(
Location 215 - 219
NR( NR( NR( NR( -(
Location 230 - 234
NR( NR( NR( NR( -(
Location 245 - 249
NR( NR( NR( NR( -(
Location 260 - 264
NR( NR( NR( NR( -(
Z07<(?":7()
(
Z07<(?":7(NN(
(
Z07<(?":7(N*(
(
(
Location 220 - 224
.( NR( NR( NR( Q(
Location 235 - 239
NR( NR( NR( NR( -(
Location 250 - 254
NR( NR( NR( NR( -(
( ( ( ( (
ISSUE140 Electronics Design and Manufacturing Pty Limited
User Codes 165
Z07<(?":7(K<&"<&%=(
There are ten different priority levels that can be allocated to the user code. Each priority level allows or restricts the functions that different user code holders may perform and can only be changed by the installer.
Once user code priority levels 4, 6, 12 or 14 have been programmed to any of the available user codes, the method of standard isolating will no longer operate. Only those user codes with the priority level of 4, 6, 12 or 14 will be able to isolate zones using the method code to isolate.
K<&"<&%=(
0
1
2
3
4
Arm/Disarm
Arm Only
F709<&5%&"'(
Arm/Disarm + Open/Close Report
Arm Only + Close Report
Arm/Disarm + Code To Isolate
K<&"<&%=(
6
8
10
12
14
F709<&5%&"'(
Arm/Disarm + Code To Isolate + Open/Close
Report
Arm/Disarm + Master Code Functions
Arm/Disarm + Master Code Functions +
Open/Close Report
Arm/Disarm + Master Code Functions + Code To
Isolate
Arm/Disarm + Master Code Functions + Code To
Isolate + Open/Close Report
Table 78: User Code Priority Levels
.(
N(
-(
Q(
T<G(1':(F&01<G(
This priority level allows the user code holder to arm and disarm the system. No opening or closing reports will be transmitted when this user code has been used to arm or disarm the system. However, a user code with this priority level will only send a closing report only after a previous code that has the ability to send an opening report has disarmed the system.
T<G(>'#=(
This priority level allows the user code holder to arm the system but not disarm it. No closing reports will be transmitted when this user code has been used to arm the system. However, a user code with this priority level will only send a closing report only after a previous code that has the ability to send an opening report has disarmed the system.
T<G(1':(F&01<G(e(>57'+?#"07(L75"<%0(
This priority level allows the user code holder to arm and disarm the system. When this user code has been used, an opening or closing report will always be transmitted along with the user number that armed or disarmed the system.
This option requires Open/Close reports in “LOCATION 333 - 334” to be enabled on page 191 for it to be effective.
T<G(>'#=(e(?#"0&'6(L75"<%0(
This priority level allows the user code holder to arm the system but not disarm it. When this user code has been used, a closing report will always be transmitted along with the user number that armed the system.
This option requires Open/Close reports in “LOCATION 333 - 334” to be enabled on page 191 for it to be effective.
Electronics Design and Manufacturing Pty Limited ISSUE140
ISSUE140
*(
,(
)(
N.(
N-(
N*(
Solution 844/862/880
Installation Manual
T<G(1':(F&01<G(e(?":7(3"(/0"#1%7(
This priority level allows the user code holder to arm and disarm the system. No opening or closing reports will be transmitted when this user code has been used to arm or disarm the system. However, a user code with this priority level will only send a closing report after a previous code that has the ability to send an opening report has disarmed the system.
Isolating zones will only be allowed by using the method “Code To Isolate” once this priority level has been set. Refer to Isolating Zones on page 70 for further information.
T<G(1':(F&01<G(e(?":7(3"(/0"#1%7(e(>57'+?#"07(L75"<%0(
This priority level allows the user code holder to arm and disarm the system. Opening and closing reports will always be transmitted when this user code has been used to arm or disarm the system. Isolating of zones will only be allowed by using the method “Code To Isolate” once this priority level has been set.
This option requires Open/Close reports in “LOCATION 333 - 334” to be enabled on page 191 for it to be effective. Refer to Isolating Zones on page 70 for more information.
T<G(1':(F&01<G(e(210%7<(?":7(@$'9%&"'0(
This priority level allows arming and disarming of the system and the ability to carry out any of the Master Code Functions described on page 99. No opening or closing reports will be transmitted when this user code has been used to arm or disarm the system. However, a user code with this priority level will only send a closing report after a previous code that has the ability to send an opening report has disarmed the system.
T<G(1':(F&01<G(e(210%7<(?":7(@$'9%&"'0(e(>57'+?#"07(L75"<%0(
This priority level allows arming and disarming of the system and the ability to carry out any of the Master Code Functions described on page 99. Opening and closing reports will always be transmitted when this user code has been used to arm or disarm the system.
This option requires Open/Close reports in “LOCATION 333 - 334” to be enabled on page 191 for it to be effective.
T<G(1':(F&01<G(e(210%7<(?":7(@$'9%&"'0(e(?":7(3"(/0"#1%7(
This priority level allows arming and disarming of the system and the ability to carry out any of the Master Code Functions described on page 99. No opening and closing reports will be transmitted when this user code has been used to arm or disarm the system. However, a user code with this priority level will only send a closing report after a previous code that has the ability to send an opening report has disarmed the system.
Isolating zones will only be allowed by using the method “Code To Isolate” once this priority level has been set. Refer to Isolating Zones on page 70 for more information.
T<G(1':(F&01<G(e(210%7<(?":7(@$'9%&"'0(e(?":7(3"(/0"#1%7(e(>57'+?#"07(
L75"<%0(
This priority level allows arming and disarming of the system and the ability to carry out any of the Master Code Functions described on page 99. Opening and closing reports will always be transmitted when this user code has been used to arm or disarm the system. This option requires Open/Close reports in “LOCATION 333 - 334” to be enabled on page 191 for it to be effective. Refer to Isolating Zones on page 70 for more information.
Isolating zones will only be allowed by using the method Code To Isolate once this priority level has been set.
Electronics Design and Manufacturing Pty Limited
J"'7(/';"<G1%&"'(
LOCATION 265
Solution 844/862/880
Installation Manual
F1=(T#1<G(J"'70(
0
When programming this location, you will notice that there are four options per location. You may select one, two, three or all four of these options, however, only one number needs to be programmed. This number is calculated by adding the option bit numbers together. Program a seven (7) if you require options 1, 2 and 4 simultaneously (i.e.. 1 + 2 + 4 = 7).
>5%&"'(
1
2
4
8
Zone 1
Zone 2
Zone 3
Zone 4
F1=(T#1<G(J"'7(
Table 79: Day Alarm Zones 1 - 4
Day alarm allows a combination of zones to be monitored while the system is in the disarmed state. Indications are available via any of the programmable outputs including the codepad buzzer. This function has been expanded to accommodate latching and non-latching day alarm output event types.
When the system has been armed in AWAY Mode, STAY Mode 1 or STAY Mode 2, zones that have been programmed as day alarm zones will activate the sirens and dialler just as non day alarm zones do. When day alarm has been activated, it will ignore any zone pulse count settings that have been programmed for that zone (i.e.. Zone pulse count is only relevant when the system has been armed).
HI1G5#7(
An example of a day alarm set up could be the front door of a shop that has a pressure mat or electronic beam that customers activate as they enter to and from the shop. As the customers walk on the pressure mat or break the electronic beam, the codepad buzzer will beep.
F1=(T#1<G(L707%%&'6(
An output that has been programmed for day alarm resetting will operate when a zone programmed for day alarm has been triggered. The output will reset once the zone has resealed. This will only occur when the system is disarmed. Refer to Output Event Type Day
Alarm Resetting on page 205 for more information.
F1=(T#1<G(\1%94&'6(
An output that has been programmed for day alarm latching will operate when a zone programmed for day alarm has been triggered. The ZONE indicator and the latching output will reset when the button has been pressed. This will only occur when the system is disarmed. Refer to Output Event Type - Day Alarm Latching on page 205 for more information.
ISSUE140 Electronics Design and Manufacturing Pty Limited
Zone Information 169
F1=(T#1<G(>57<1%&"'(
If a zone has been programmed for day alarm, the zone can be isolated in the normal way so that it does not register as a day alarm zone during the disarmed state. Only zones 1 – 4 can be used as day alarm zones.
The
STAY
indicator can be programmed to indicate whether day alarm has been turned on or off. When day alarm has been turned on, the STAY indicator will flash once every three seconds. Refer to Option 8 in “LOCATION 428” on page 233 for more information.
Monitoring of zones 5 – 8 can be achieved by programming an output to mimic a zone. Refer to Output Event Types on page 204 for more information on all available output types that can be programmed.
C"D(3"(3$<'(F1=(T#1<G(>'(
1.
Hold down the
4
button until three beeps are heard.
C"D(3"(3$<'(F1=(T#1<G(>;;(
1.
Hold Down the
4
button until two beeps are heard.
Electronics Design and Manufacturing Pty Limited ISSUE140
Solution 844/862/880
Installation Manual
H>\(L70&0%"<(P1#$7(
LOCATION 266
>5%&"'(
0
L70&0%"<(P1#$7(
No EOL Resistor
1
1K (Brown, Black, Red)
1K5 (Brown, Green, Red)
2
3
4
2K2 (Red, Red, Red)
3K3 (Orange, Orange, Black, Brown) 1%
5
6
7
3K9 (Orange, White, Red)
4K7 (Yellow, Violet, Red)
5K6 (Green, Blue, Red)
>5%&"'(
8
9
10
11
12
L70&0%"<(P1#$7(
6K8 (Blue, Grey, Black, Brown) 1%
10K (Brown, Black, Orange)
12K (Brown, Red, Orange)
22K (Red, Red, Orange)
Reserved
13
Reserved
14
15
Table 80: EOL Resistor Value
Reserved
Split EOL (3K3/6K8) 1% Resistors Required
Four Burglary Zones & Four 24 Hour Zones.
The control panel has the ability to be programmed for different values of EOL (End Of Line) resistors. This is a global parameter and will effect all four zones simultaneously. It gives the ability to fit the
Solution 844/862/880
control panel into an existing installation without having to change the EOL resistors. This feature also increases the security of the system as there are eleven possible EOL resistor values that can be used. This makes it extremely difficult for anyone to tamper with the system.
If split EOL resistors have been selected, the control panel will look for four burglary zones (1-
4) consisting of 3K3 EOL resistors and four 24 hour zones (5–8) consisting of 6K8 resistors connected in parallel. The zone 1 terminal on the PCB becomes the terminal for zones 1 and 5.
Caution should be exercised when using split EOL resistors to create four burglary zones and four 24 hour zones. This configuration is only suitable for normally closed contacts. If normally open contacts are used, as is the case with most types of smoke detectors, a short circuit on one zone will trigger both zones connected in parallel.
If you require N/O contacts when using split EOL resistors, refer Connections Of Split
EOL Resistors Using N/O Contacts on page 172 for information on how to connect N/O contacts.
ISSUE140 Electronics Design and Manufacturing Pty Limited
Zone Information
?"''79%&"'0(>;(!5#&%(H>\(L70&0%"<0(Z0&'6(E+?(?"'%19%0(
171
Figure 8: Connections Of Split EOL Resistors For 8 Zones
Electronics Design and Manufacturing Pty Limited ISSUE140
Solution 844/862/880
Installation Manual
?"''79%&"'0(>;(!5#&%(H>\(L70&0%"<0(Z0&'6(E+>(?"'%19%0(
Figure 9: Connections Of Split EOL Resistors Using One N/O Contact
ISSUE140
Figure 10: Connections Of Split EOL Using Two N/O Contacts
Electronics Design and Manufacturing Pty Limited
Zone Information
J"'7(K<"6<1GG&'6(
173
Each zone contains seven locations that are divided into three groups. The first 3 locations determine how the zone will operate, the next two locations allow various options for each zone and the last two locations contain the dialler reporting information of each zone.
J"'7(>57<1%&'6(/';"<G1%&"'(
J"'7(3=57(
This location programs the "Zone Type" required (e.g.. Delay-1, Instant, 24 Hour etc).
J"'7(K$#07(?"$'%(
This location sets how many times the zone must trigger within the time specified in the "Zone
Pulse Count Time”.
J"'7(K$#07(?"$'%(3&G7(
This parameter sets the time period for the number of times the zone must trigger before activating an alarm.
J"'7(>5%&"'0(
J"'7(>5%&"'0(N(
This location controls the zone (e.g.. Lockout Siren, Silent etc).
J"'7(>5%&"'0(-(
This location controls the zone (e.g.. Isolate In STAY Mode 1, Forced Arming Allowed etc).
J"'7(L75"<%&'6(/';"<G1%&"'(
J"'7(L75"<%(?":7(
If you wish the control panel to transmit zone alarm reports, this location should be programmed as 1. If you do not wish to transmit zone alarm reports, this location should be programmed as a 0.
J"'7(F&1##7<(>5%&"'0(
This location is factory default to report only to receiver 1. You can select each zone to report on receiver 1, receiver 2, both receiver 1 and receiver 2, receiver 2 only when receiver 1 fails or no reporting at all. Select the required dialler option from the table below.
>5%&"'(
0
No Report Required
F709<&5%&"'(
1
2
4
8
Receiver 1
Receiver 2
Receiver 1 and Receiver 2
Receiver 2 Only When Receiver 1 Fails
Table 81: Zone Dialler Options
Electronics Design and Manufacturing Pty Limited ISSUE140
Solution 844/862/880
Installation Manual
LOCATION 267 - 322
!"#$%&"'()**(J"'70(F7;1$#%0(
J"'7(N(
Location 267 - 273
J"'7(-(
Location 274 - 280
( ( ( ( ( ( ( ( ( -( .( .( N( N*( N( N( ( ( N( .( .( N( N*( N( N(
J"'7(Q(
Location 281 - 287
J"'7(*(
Location 288 - 294
J"'7(R(
Location 295 – 301
N( .( .( N( N*( N( N( ( ( .( .( .( N( N*( N( N( ( ( N-( .( .( N( N-( N( N(
J"'7(,(
Location 302 - 308
J"'7(S(
Location 309 - 315
J"'7()(
Location 316 - 322
N-( .( .( N( N-( N( N( ( ( NQ( .( .( N( N-( N( N( ( ( X( .( .( N( N-( N( N(
(
J"'7(
3=57(
(
J"'7(K$#07(
?"$'%(
(
J"'7(K$#07(
?"$'%(3&G7(
(
J"'7(
>5%&"'(N(
(
J"'7(
>5%&"'(-(
(
L75"<%(
?":7(
(
F&1##7<(
>5%&"'0(
LOCATION 267 - 322
Zones 1 – 4 may be programmed as any zone type, whereas zones 5 – 8 may only be programmed to any 24-hour zone type.
!"#$%&"'(),-(J"'70(F7;1$#%0(
J"'7(N(
Location 267 - 273
J"'7(-(
Location 274 - 280
( ( ( ( ( ( ( ( ( -( .( .( N( N*( N( N( ( ( N( .( .( N( N*( N( N(
J"'7(Q(
Location 281 - 287
J"'7(*(
Location 288 - 294
J"'7(R(
Location 295 – 301
N( .( .( N( N*( N( N( ( ( N( .( .( N( N*( N( N( ( ( .( .( .( N( N*( N( N(
J"'7(,(
Location 302 - 308
J"'7(S(
Location 309 - 315
J"'7()(
Location 316 - 322
.( .( .( N( N*( N( N( ( ( NQ( .( .( N( N-( N( N( ( ( X( .( .( N( N-( N( N(
(
J"'7(
3=57(
(
J"'7(K$#07(
?"$'%(
(
J"'7(K$#07(
?"$'%(3&G7(
(
J"'7(
>5%&"'(N(
(
J"'7(
>5%&"'(-(
(
L75"<%(
?":7(
(
F&1##7<(
>5%&"'0(
LOCATION 267 - 322
Zones 1 – 6 may be programmed as any zone type, whereas zones 7 and 8 may only be programmed to any 24-hour zone type.
!"#$%&"'()).(J"'70(F7;1$#%0(
J"'7(N(
Location 267 - 273
J"'7(-(
Location 274 - 280
( ( ( ( ( ( ( ( ( -( .( .( N( N*( N( N( ( ( N( .( .( N( N*( N( N(
J"'7(Q(
Location 281 - 287
J"'7(*(
Location 288 - 294
J"'7(R(
Location 295 – 301
N( .( .( N( N*( N( N( ( ( N( .( .( N( N*( N( N( ( ( .( .( .( N( N*( N( N(
J"'7(,(
Location 302 - 308
J"'7(S(
Location 309 - 315
J"'7()(
Location 316 - 322
.( .( .( N( N*( N( N( ( ( .( .( .( N( N*( N( N( ( ( X( .( .( N( N-( N( N(
(
J"'7(
3=57(
( ( ( (
J"'7(K$#07(
?"$'%(
J"'7(K$#07(
?"$'%(3&G7(
J"'7(
>5%&"'(N(
Zones 1 – 8 may be programmed as any zone type.
J"'7(
>5%&"'(-(
(
L75"<%(
?":7(
(
F&1##7<(
>5%&"'0(
ISSUE140 Electronics Design and Manufacturing Pty Limited
Zone Information
.(
N(
-(
Q(
*(
175
J"'7(3=570(
There are sixteen different zone types to choose from. Refer to the table below for the different zone types available.
J"'7(3=57(
0
1
2
3
4
5
6
7
Instant
Handover
F709<&5%&"'(
Delay-1
Delay-2
Reserved
Reserved
24 Hour Medical
24 Hour Panic
J"'7(3=57(
8
9
10
11
12
13
14
15
F709<&5%&"'(
24 Hour Hold-Up
24 Hour Tamper
Reserved
Keyswitch
24 Hour Burglary
24 Hour Fire
Chime Only
Zone Not Used
Table 82: Zone Types
/'0%1'%(J"'7(
An Instant zone (Contact ID Event Code 130) will sound the sirens and operate the dialler as soon as it registers as unsealed after the exit timer has expired.
If an Instant zone has not restored at the time the system is disarmed, a zone restore report will be automatically sent to the receiving party.
C1':"M7<(J"'7(
A Handover zone (Contact ID Event Code 130) will act as an instant zone if it has been triggered by itself. If a handover zone has triggered after a delay zone, the remaining delay time will handover from the delay zone to the handover zone. Handover may be sequential or non sequential. The control panel is factory default with sequential handover. Refer to Option
8 in "LOCATION 426" on page 231 if you require handover to be non sequential.
If a Handover zone has not restored at the time the system is disarmed, a zone restore report will be automatically sent to the receiving party.
F7#1=YN(J"'7(
A Delay-1 zone (Contact ID Event Code 130) will have a delay time determined by the value in Entry Timer 1 on page 218. After entry time has expired, the system will activate into alarm condition.
If a Delay-1 zone has not restored at the time the system is disarmed, a zone restore report will be automatically sent to the receiving party.
F7#1=Y-(J"'7(
A Delay-2 zone (Contact ID Event Code 130) will have a delay time determined by the value in Entry Timer 2 on page 218. After entry time has expired, the system will activate into alarm condition.
If a Delay-2 zone has not restored at the time the system is disarmed, a zone restore report will be automatically sent to the receiving party.
L707<M7:(
Electronics Design and Manufacturing Pty Limited ISSUE140
ISSUE140
Solution 844/862/880
Installation Manual
L707<M7:(
R(
,(
S(
)(
X(
-*(C"$<(27:&91#(
A 24 Hour Medical zone (Contact ID Event Code 100) is always ready to trigger the dialler, horn speaker, bell and strobe regardless of whether the system is in the armed or disarmed state. A medical report will be transmitted to the base station receiver. A 24 Hour Medical zone will not send a restore report until the zone actually restores.
-*(C"$<(K1'&9(
A 24 Hour Panic zone (Contact ID Event Code 120) is always ready to trigger the dialler, horn speaker, bell and strobe regardless of whether the system is in the armed or disarmed state. A panic report will be transmitted to the base station receiver. A 24 Hour Panic zone will not send a restore report until the zone actually restores.
-*(C"$<(C"#:YZ5(
A 24 Hour Hold-Up zone (Contact ID Event Code 122) is always ready to trigger the dialler, horn speaker, bell and strobe regardless of whether the system is in the armed or disarmed state. If you require the hold-up alarm to be silent, enable Option 4 – Silent Alarm in Zone
Options 1 on page 179. A 24 Hour Hold-Up zone will not send a restore report until the zone actually restores.
-*(C"$<(31G57<(
A 24 Hour Tamper zone (Contact ID Event Code 137) is always ready to trigger the dialler, horn speaker, bell and strobe regardless of whether the system is in the armed or disarmed state. A 24 Hour Tamper zone will not send a restore report until the zone actually restores.
L707<M7:(
N.(
NN(
N-(
NQ(
U7=0D&%94(J"'7(
A Keyswitch zone is used when you need to connect a keyswitch to operate the system. Refer to Keyswitch Zone Options on page 181 for selecting options such as momentary, toggle etc.
User code number 16 will be reported when arming and disarming using this method of operation. Programming the polarity level of user code 16 will also effect the operation of the keyswitch zone. Refer to User Code Priority on page 165 for more information.
-*(C"$<(V$<6#1<=(J"'7(
A 24 Hour Burglary zone (Contact ID Event Code 133) is always ready to trigger the dialler, horn speaker, bell and strobe regardless of whether the system is in the armed or disarmed state. A 24 Hour Burglary zone will not send a restore report until the zone actually restores.
-*(C"$<(@&<7(J"'7(
A 24 Hour Fire zone (Contact ID Event Code 110) is always ready to trigger the dialler, horn speaker, bell and strobe regardless of whether the system is in the armed or disarmed state. A distinct fire sound is emitted through the horn speaker to indicate this type of alarm condition.
This fire sound is completely different to the burglary sound. A 24 Hour Fire zone will not send a restore report until the zone actually restores.
Electronics Design and Manufacturing Pty Limited
Zone Information
N*(
NR(
177
?4&G7(J"'7(
A Chime zone is not a burglary zone. It can never sound the sirens or trigger the dialler. Its purpose is to map it to a programmable output for an indication of sealed or unsealed state.
Refer to Output Event Type - Global Chime on page 210.
Chime zones require EOL resistors and they will register at a remote codepad. These zones do not effect the operation of forced arming.
J"'7(E"%(Z07:((
If a zone is not used, program it as a zone type of 15. This zone will never sound the sirens or trigger the dialler. An EOL resistor is not required if this zone type is used.
J"'7(K$#07(?"$'%(
Zone pulse count is the number of times a zone must be triggered before the zone registers as an alarm. The number of pulses vary between 0 – 15. The zone pulse count value is relative to the time frame (i.e.. The number of pulses must be present during a particular time frame.
Refer to “Table 84: Zone Pulse Count Times” on page 178 for time frame settings.
3
4
5
6
7
>5%&"'(
0
1
2
E$G87<(>;(K$#070(
1
1
2
3
4
5
6
7
>5%&"'(
8
9
10
11
12
13
14
15
E$G87<(>;(K$#070(
8
9
10
11
12
13
14
15
Table 83: Number Of Pulses
Zones that have been programmed with pulse count which are continuously unsealed for
10 seconds will activate an alarm condition. 24 Hour Fire zones that have been programmed with pulse count which are continuously unsealed for 30 seconds will activate an alarm condition.
J"'7(K$#07(?"$'%(C1':"M7<(
Zone pulse count handover will only operate with zone pulse count time options 8 – 15. Refer to Zone Pulse Count Time on page 178 for more information.
Any zone that registers one trigger pulse will automatically increment any other zone pulse count that has already registered at least one trigger pulse during its respective time. To enable this option, refer to Option 4 in “LOCATION 426” on page 231.
24 Hour zones do not receive any handover pulses from other zones. 24 Hour zones may handover pulses to other zones.
Electronics Design and Manufacturing Pty Limited ISSUE140
Solution 844/862/880
Installation Manual
J"'7(K$#07(?"$'%(3&G7(
Zone pulse count time is the time frame or period over which the programmed number of pulses must register before an alarm condition is generated.
-.(G0(\""5(L705"'07(3&G7(
>5%&"'( K$#07(?"$'%(3&G7(
0
0.5 Seconds
1
2
3
4
5
6
7
1 Second
2 Seconds
3 Seconds
4 Seconds
5 Seconds
10 Seconds
15 Seconds
NR.(G0(\""5(L705"'07(3&G7(
>5%&"'( K$#07(?"$'%(3&G7(
8
9
10
11
12
13
14
15
Table 84: Zone Pulse Count Times
20 Seconds
30 Seconds
40 Seconds
50 Seconds
60 Seconds
90 Seconds
120 Seconds
200 Seconds
For zone pulse count time, options 0 – 7 have a zone loop response time of 20 ms. For zone pulse count time, options 8 – 15 have a zone loop response time of 150 ms. Loop response time is the length of time a zone must be unsealed before it can register as a valid pulse.
Inertia sensors should use options 0 - 7, while PIR detectors should use options 8 – 15.
24 Hour zones do not receive any handover pulses from other zones. 24 Hour zones may handover pulses to other zones.
ISSUE140 Electronics Design and Manufacturing Pty Limited
Zone Information 179
J"'7(>5%&"'0(N(
When programming this location, you will notice that there are four options per location. You may select one, two, three or all four of these options, however, only one number needs to be programmed. This number is calculated by adding the option bit numbers together. Program a seven (7) if you require options 1, 2 and 4 simultaneously (i.e.. 1 + 2 + 4 = 7).
>5%&"'(
1
2
4
8
F709<&5%&"'(
Lockout Siren/Lockout Dialler
Delay Alarm Reporting
Silent Alarm
Sensor Watch
Table 85: Zone Options 1
N(
\"9B"$%(!&<7'(h(\"9B"$%(F&1##7<(
Lockout means one activation per arming cycle (i.e.. A zone programmed for "Lockout" can only cause the sirens or dialler to operate once).
When the system is next armed, the zone can cause the sirens and dialler to operate once more.
Restore signals will be transmitted when the system has been disarmed.
The
Solution 844/862/880
control panel performs lockout different to most other control panels in that only the first zone to trigger an alarm condition will be locked out. All other zones that are triggered during the same siren run time will reset when the sirens reset.
This prevents an intruder from triggering all zones then waiting for the sirens to stop before reentering the premises.
HI1G5#7(
-(
All zones are programmed for both lockout siren and dialler. Zone 1 is triggered followed by all other zones causing the sirens to sound and the dialler to report to the base station receiver.
Zone 1 will be the only zone that stops reporting to the base station receiver because of the first zone to trigger is locked out. The remaining zones will continue to report if they are triggered again.
Refer to Swinger Shutdown Count For Siren on page 185 to set the number of times the siren will be allowed to activate before it will be locked out and Swinger Shutdown Count For
Dialler on page 186 to set the number of times the dialler will activate before lockout will take effect.
F7#1=(T#1<G(L75"<%&'6(
This option will allow the reporting of alarms on selected zones to be delayed to allow the user to enter their code to cancel alarms that are not required to report. All sounding devices (e.g.: horn speaker, strobe and bell outputs) will operate as soon as the alarm condition occurs, but the dialler will not operate until the delay time in “LOCATION 406 – 407” on page 219 has expired.
Electronics Design and Manufacturing Pty Limited ISSUE140
*(
)(
Solution 844/862/880
Installation Manual
!'%(T#1<G(
A zone programmed to be silent will not activate the horn speaker, bell strobe or EDMSAT outputs. The dialler and all other programmable outputs will function as per their particular programming.
!7'0"<(O1%94(
Sensor watch gives the control panel the ability to recognise that detection devices may have stopped working. This is a feature that monitors the operation of a zone over a programmed time period. Refer to "LOCATION 408 - 409" on page 220 for programming sensor watch time.
This value determines how many 24 hour periods a zone may remain continuously sealed before it registers as a sensor watch fault. The number of hours required to fulfil these 24 hour periods is only calculated while the system is in the disarmed state. Every time the system is armed in AWAY Mode, STAY Mode 1 or STAY Mode 2, the sensor watch timer pauses calculating. Sensor watch timer will continue calculating the next time the system has been disarmed.
HI1G5#7(
If the sensor watch time is programmed for two days in a situation where a premises is armed for twelve hours and disarmed for twelve hours each day, it will take four days before a zone can register as a faulty sensor watch zone.
ISSUE140 Electronics Design and Manufacturing Pty Limited
Zone Information
.(
N(
-(
*(
R(
,(
U7=0D&%94(J"'7(>5%&"'0(
When you select a zone to be a keyswitch input, then the following table relates to the options available to that keyswitch zone. These keyswitch zone options replace Zone Options 1 only for the zones that have been programmed to operate as a keyswitch zone. Keyswitch zones will report as user code 16.
>5%&"'( F709<&5%&"'(
0
Latching Arm and Disarm In AWAY Mode
181
1
Latching Arm In AWAY Mode
2
Latching Disarm From AWAY Mode, STAY Mode 1 Or STAY Mode 2
4
5
Latching Arm and Disarm In STAY Mode 1
Latching Arm In STAY Mode 1
6
8
9
10
12
13
14
Latching Disarm From STAY Mode 1 Or STAY Mode 2
Momentary Arm and Disarm In AWAY Mode
Momentary Arm In AWAY Mode
Momentary Disarm From AWAY Mode, STAY Mode 1 Or STAY Mode 2
Momentary Arm and Disarm In STAY Mode 1
Momentary Arm In STAY Mode 1
Momentary Disarm From STAY Mode 1 Or STAY Mode 2
Table 86: Keyswitch Zone Options
\1%94&'6(T<G(1':(F&01<G(/'(TOT](2":7(
If this option has been selected, the system will either arm or disarm from AWAY Mode when using the latching keyswitch input.
\1%94&'6(T<G(/'(TOT](2":7(
If this option has been selected, the system will arm in AWAY Mode when using the latching keyswitch input. Disarming the system will not be permitted via the keyswitch zone if this option has been selected.
\1%94&'6(F&01<G(@<"G(TOT](2":7f(!3T](2":7(N(><(!3T](2":7(-(
If this option has been selected, the system will disarm from AWAY Mode, STAY Mode 1 or
STAY Mode 2 when using the latching keyswitch input. Arming the system will not be permitted via the keyswitch zone if this option has been selected.
\1%94&'6(T<G(1':(F&01<G(/'(!3T](2":7(N(
If this option has been selected, the system will arm or disarm in STAY Mode 1 when using the latching keyswitch input. Arming and disarming the system in AWAY Mode will not be permitted via the keyswitch zone if this option has been selected.
\1%94&'6(T<G(/'(!3T](2":7(N(
If this option has been selected, the system will arm in STAY Mode 1 when using the latching keyswitch input. Arming the system in AWAY Mode or disarming the system will not be permitted via the keyswitch zone if this option has been selected.
\1%94&'6(F&01<G(@<"G(!3T](2":7(N(><(!3T](2":7(-(
If this option has been selected, the system will only disarm from STAY Mode 1 or STAY
Mode 2 when using the latching keyswitch input. Arming the system in STAY Mode 1, STAY
Mode 2 or arming and disarming the system in AWAY Mode will not be permitted via the keyswitch zone if this option has been selected.
Electronics Design and Manufacturing Pty Limited ISSUE140
)(
X(
N.(
N-(
NQ(
N*(
Solution 844/862/880
Installation Manual
2"G7'%1<=(T<G(1':(F&01<G(/'(TOT](2":7(
If this option has been selected, the system will either arm or disarm from AWAY Mode when using the momentary keyswitch input.
2"G7'%1<=(T<G(/'(TOT](2":7(
If this option has been selected, the system will arm in AWAY Mode when using the momentary keyswitch input. Disarming the system will not be permitted via the keyswitch zone if this option has been selected.
2"G7'%1<=(F&01<G(@<"G(TOT](2":7f(!3T](2":7(N(><(!3T](2":7(-(
If this option has been selected, the system will disarm from either AWAY Mode, STAY Mode
1 or STAY Mode 2 when using the momentary keyswitch input. Arming the system will not be permitted via the keyswitch zone if this option has been selected.
2"G7'%1<=(T<G(1':(F&01<G(/'(!3T](2":7(N(
If this option has been selected, the system will arm or disarm in STAY Mode 1 when using the momentary keyswitch input. Arming and disarming the system in AWAY Mode will not be permitted via the keyswitch zone if this option has been selected.
2"G7'%1<=(T<G(/'(!3T](2":7(N(
If this option has been selected, the system will arm in STAY Mode 1 when using the momentary keyswitch input. Arming the system in AWAY Mode or disarming the system will not be permitted via the keyswitch zone if this option has been selected.
2"G7'%1<=(F&01<G(@<"G(!3T](2":7(N(><(!3T](2":7(-(
If this option has been selected, the system will only disarm the system from STAY Mode 1 or
STAY Mode 2 when using the momentary keyswitch input. Arming the system in STAY
Mode 1, STAY Mode 2 or arming and disarming the system from AWAY Mode will not be permitted via the keyswitch zone if this option has been selected.
Figure 11: Wiring Diagram For Keyswitch Zone
ISSUE140 Electronics Design and Manufacturing Pty Limited
Zone Information
N(
-(
*(
)(
183
J"'7(>5%&"'0(-(
When programming this location, you will notice that there are four options per location. You may select one, two, three or all four of these options, however, only one number needs to be programmed. This number is calculated by adding the option bit numbers together. Program a seven (7) if you require options 1, 2 and 4 simultaneously (i.e.. 1 + 2 + 4 = 7).
>5%&"'(
1
2
4
8
F709<&5%&"'(
Isolate In STAY Mode 1
Zone Isolation Allowed
Forced Arming Allowed
Zone Restore Report
Table 87: Zone Options 2
/0"#1%7(/'(!3T](2":7(N(
If this option has been selected, it will allow the zone to be automatically isolated when the system has been armed in STAY Mode 1.
If this option is not selected, when the system has been armed in STAY Mode 1, the zone will activate an alarm when triggered as it normally would in AWAY Mode.
Refer to Entry Guard Timer For STAY Mode on page 219 if you wish to program a global entry time for ALL zones except for 24 hour zone types when armed in STAY Mode 1 (i.e..
The entry guard timer will override the delay time programmed for a delay zone). If the entry guard timer has been programmed as "0" each zone will act as per its programmed zone type.
Refer to Arming The System In STAY Mode 1 on page 64 for more information.
J"'7(/0"#1%&"'(T##"D7:(
If this option has been selected, it will allow the system user to isolate the zone before arming the system. If this option is not selected, the zone can not be manually isolated. When a zone has been manually isolated, a zone bypass report (Contact ID Event Code 570) will be sent.
Refer to Isolating Zones on page 70 for more information.
When isolating 24 hour zone types, the 24 hour zone will automatically send a zone bypass report at the time the zone is selected to be isolated. All non 24 hour zone types will only send a bypass report at the time the system is armed.
If you require the system not to report zone bypass reports, program “LOCATION 325 - 326” on page 188 as zeros.
@"<97:(T<G&'6(T##"D7:(
If this option has been selected, it will allow the system to be armed with the zone unsealed. If this option is not selected, the system will not allow the user code holder to arm the system until the zone in question has been sealed or manually isolated. Refer to Isolating Zones on page 70 for more information.
J"'7(L70%"<7(L75"<%(
If this option has been selected, the zone will send restore reports as soon as the zone has restored. If this option has not been selected, the zone will not send restore reports after the zone has restored.
If a non 24 hour zone has not restored at the time the system is disarmed, the system will automatically send a zone restore report for that zone. All 24 hour zone types will only a send zone restore report at the time the zone has restored.
Electronics Design and Manufacturing Pty Limited ISSUE140
Solution 844/862/880
Installation Manual
J"'7(L75"<%&'6(/';"<G1%&"'(
J"'7(L75"<%(?":7(
If you wish the control panel to transmit zone alarm reports, this location should be programmed as 1. If you do not wish to transmit zone alarm reports, this location should be programmed as a 0.
J"'7(F&1##7<(>5%&"'0(
This location is factory default to report only to receiver 1. You can select each zone to report on receiver 1, receiver 2, both receiver 1 and receiver 2, receiver 2 only when receiver 1 fails or no reporting at all. Select the required dialler option from the table below.
>5%&"'(
0
1
2
4
8
F709<&5%&"'(
No Report Required
Receiver 1
Receiver 2
Receiver 1 and Receiver 2
Receiver 2 Only When Receiver 1 Fails
Table 88: Zone Dialler Options
ISSUE140 Electronics Design and Manufacturing Pty Limited
Zone Information
LOCATION 323
\"91%&"'(
323
185
!D&'67<(!4$%:"D'(?"$'%(@"<(!&<7'(
3
F709<&5%&"'(
Swinger Shutdown Count For Siren (0-15)
Table 89: Swinger Shutdown Count For Siren Location
This location determines the number of times the sirens can be triggered before any lockout options will take effect. A minimum of one zone must be programmed for lockout siren for this location to be effective. Refer to Zone Options 1 on page 179 to program zones for lockout siren.
Only alarms triggered from zone inputs will increment the swinger shutdown counter. This means alarms such as codepad panic, access denied and any other system alarms will not effect the swinger shutdown count.
While the sirens are operating, the counter for the sirens is only incremented by the first zone that causes the alarm. Any other zones that are triggered during siren run time will not effect the counter. While the dialler is on line, its counter is only incremented by the first zone that causes the alarm. Any other zones that are triggered while the dialler is on line will not effect the counter.
When the swinger shutdown count (As programmed in “LOCATION 323”) has been reached, all zones that have been triggered will be locked out according to their individual lockout settings.
HI1G5#7(
All eight zones have been programmed for lockout siren with a swinger shutdown count of 3.
If zone 1 triggers an alarm, the swinger shutdown count will decrement by one after the end of siren run time to a swinger shutdown count of 2.
After the siren run time has reset from the previous alarm, zone 2 triggers an alarm and reactivates the sirens. After the sirens have reset, the swinger shutdown count has decremented again from 2 to 1.
If zone 3 also triggers an alarm after the sirens have reset from zone 2, the swinger shutdown count has decremented from 1 to 0, therefore locking out all three zones from sounding the sirens again until the system has been reset.
However, at this point in time, the swinger shutdown count for sirens has again a lockout count of 3 and the process of swinger shutdown for the remaining zones begin again until all zones have been locked out.
The Swinger Shutdown Count For Siren is global to both Area 1 and Area 2 when using a
Solution 880
control panel that has been partitioned.
Electronics Design and Manufacturing Pty Limited ISSUE140
LOCATION 324
\"91%&"'(
324
Solution 844/862/880
Installation Manual
!D&'67<(!4$%:"D'(?"$'%(@"<(F&1##7<(
6
F709<&5%&"'(
Swinger Shutdown Count For Dialler (0-15)
Table 90: Swinger Shutdown Count For Dialler Location
This location determines the number of times the dialler can be triggered before any lockout options will take effect. A minimum of one zone must be programmed for lockout dialler for this location to be effective. Refer to Zone Options 1 on page 179 to program zones for lockout dialler.
Only alarms triggered from zone inputs will increment the swinger shutdown counter. This means alarms such as codepad panic, code retries and any other system alarms will not effect the swinger shutdown count.
While the sirens are operating, the counter for the dialler is only incremented by the first zone that causes the alarm. Any other zones that are triggered during siren time will not effect the counter. While the dialler is on line, its counter is only incremented by the first zone that causes the alarm. Any other zones that are triggered while the dialler is on line will not effect the counter.
When the swinger shutdown count (As programmed in "LOCATION 324") has been reached, all zones that have been triggered will be locked out according to their individual lockout settings.
If "Lockout Dialler" has been enabled for any zone, the last restore signal will not be transmitted until the system or area (If partitioned) has been disarmed.
The Swinger Shutdown Count For Dialler is global to both Area 1 and Area 2 when using a
Solution 880
control panel that has been partitioned.
HI1G5#7(
All eight zones have been programmed for lockout dialler with a swinger shutdown count of 6.
If zone 1 triggers an alarm, the swinger shutdown count will decrement by one at the time the control panel makes the call to a swinger shutdown count of 5.
If zone 1 re-triggers the dialler, the swinger shutdown count will be decremented by one to a swinger shutdown count of 4. If zone 1 re-triggers the dialler 3 more times, the swinger shutdown count will be 1.
If zone 2 triggers an alarm, the swinger shutdown count will be decremented by one to a swinger shutdown count of zero, therefore, locking out zone 2 from activating the dialler again until the system has been reset. However, at this point in time, the swinger shutdown count for the dialler has again a lockout count of 6 and the process of swinger shutdown for the remaining zones including zone 1 begin again until all zones have been locked out.
ISSUE140 Electronics Design and Manufacturing Pty Limited
!=0%7G(L75"<%&'6(/';"<G1%&"'(
L75"<%&'6(/';"<G1%&"'(
This section covers features that are involved with the basic house keeping of the system. This includes monitoring of the zones - whether they are isolated from the system or more importantly that they are actually operating, the status of both the AC mains and DC power to the system and codepad generated alarms activated by the user.
LOCATION 325 - 326
J"'7(!%1%$0(c(V=5100(L75"<%0(
98
\"91%&"'( F709<&5%&"'(
325
326
Zone Bypass Report
Zone Bypass Restore Report
Solution 844/862/880
Installation Manual
Table 91: Zone Status - Bypass Report Locations
A zone is bypassed when it is manually isolated. Refer to Isolating Zones on page 70 for information on isolating zones. A "Zone Bypass" report (Contact ID Event Code 570) will be transmitted at the end of exit time for any zone that has been manually isolated. 24-hour zones will send a “Zone Bypass” report at the time the zone has been selected to be isolated.
A "Zone Bypass Restore" report will be transmitted when the system has been disarmed. All bypassed zones are automatically cleared when the system has been disarmed.
The bypass code parameter is used as the expansion digit in 4+2 Formats. It has no effect on
Contact ID Format as a zone bypass will always be reported on event code 570.
If "Zone Bypass" reports are not required, program "LOCATION 325 - 326" with a zero.
ISSUE140 Electronics Design and Manufacturing Pty Limited
System Reporting Information
LOCATION 327 – 328
\"91%&"'(
327
328
189
J"'7(!%1%$0(c(3<"$8#7(L75"<%0(
23
F709<&5%&"'(
Zone Trouble Report
Zone Trouble Restore Report
Table 92: Zone Status - Trouble Report Locations
A zone is in trouble when it is unsealed at the end of exit time. A "Sensor Trouble" report
(Contact ID Event Code 380) will be transmitted to indicate that one or more zones have been automatically isolated by the system. 24-hour zones that are unsealed at the end of exit time will not transmit a "Sensor Trouble" report as the restore for that zone is still outstanding.
A "Sensor Trouble" restore report will be transmitted for burglary zones when the zone reseals or when the system is next disarmed (which ever happens first). A 24-hour zone will only transmit a restore signal when it has resealed.
The trouble code parameter is used as the expansion digit in 4+2 Format. It has no effect on
Contact ID Format as a "Sensor Trouble" report will always be reported on event code 380.
If "Sensor Trouble" reports are not required, program "LOCATION 327 – 328" with a zero.
Electronics Design and Manufacturing Pty Limited ISSUE140
LOCATION 329 - 330
\"91%&"'(
329
330
Solution 844/862/880
Installation Manual
J"'7(!%1%$0(c(!7'0"<(O1%94(L75"<%0(
45
F709<&5%&"'(
Sensor Watch Report
Sensor Watch Restore Report
Table 93: Zone Status – Sensor Watch Report Locations
A "Self Test Failure" report (Contact ID Event Code 307) will be transmitted to the base station receiver when a zone has not been triggered during the Sensor Watch Time programmed in "LOCATION 408 - 409" on page 220. This report will continue to be transmitted (according to the frequency of the sensor watch time) until the fault has been rectified.
To clear the fault and stop any further reporting, the zone that registered the fault must be unsealed and resealed again. Refer to "LOCATION 408 - 409" on page 220 to set the number of days a zone may remain sealed before registering as a fault. Refer to Zone Options 1 on page 179 to program zones to be monitored by the sensor watch feature.
If "Self Test Failure" reports are not required, program "LOCATION 329 - 330" with a zero.
LOCATION 331
LOCATION 332
ISSUE140
J"'7(!%1%$0(c(T#1<G(L70%"<7(?":7(
If you wish the control panel to transmit zone alarm restore reports, this location should be programmed as 14. If you do not wish to transmit zone restore reports, this location should be programmed as a zero.
“LOCATION 332” will be ignored when programming the alarm restore code and is global for all zones. A zone restore report will only report to the receiving party that the zone has been allocated to (e.g.: Receiver 1 or Receiver 2 etc).
J"'7(!%1%$0(L75"<%&'6(>5%&"'0(
1
>5%&"'(
0
1
2
4
8
F709<&5%&"'(
No Report Required
Receiver 1
Receiver 2
Receiver 1 and Receiver 2
Receiver 2 Only When Receiver 1 Fails
Table 94: Zone Status Reporting Options Location
This location is factory default to report only to receiver 1. You can select whether the zone status reports will report on, receiver 1, receiver 2, both receiver 1 and receiver 2, receiver 2 only when receiver 1 fails or no reporting at all.
When using partitioned
Solution 880
control panels, this location will be ignored if Option
1 – Lock Area 1 to Receiver 1 & Lock Area 2 to Receiver 2 in “LOCATION 433” on page 244 has been programmed.
Electronics Design and Manufacturing Pty Limited
System Reporting Information
LOCATION 333 - 334
191
>57'+?#"07(L75"<%0(
\"91%&"'(
333
334
F709<&5%&"'(
Opening Report
Closing Report
Table 95: Open/Close Reporting Locations
An "Opening" report (Contact ID Event Code 401) will be transmitted to the base station receiver when the system has been disarmed from AWAY Mode. A "Closing" report (Contact
ID Event Code 401) is transmitted at the end of exit time when the system has been armed in
AWAY Mode.
If an expanded format has been selected, this code will be used as the expansion code and the user number that armed or disarmed the system will follow in the same transmission.
Refer to Option 2 in "LOCATION 178" on page 158 for programming "Open/Close" reports in
STAY Mode. To program "Open/Close" reports only after a previous alarm, refer to Option 1 in "LOCATION 178" on page 158.
If you do not require "Open/Close" reports, program "LOCATION 333 - 334" with zero.
LOCATION 335
>57'+?#"07(L75"<%&'6(>5%&"'0(
1
>5%&"'(
0
1
2
4
8
F709<&5%&"'(
No Report Required
Receiver 1
Receiver 2
Receiver 1 and Receiver 2
Receiver 2 Only When Receiver 1 Fails
Table 96: Open/Close Reporting Options Location
This location is factory default to report only to receiver 1. You can select whether the open/close reports will report on receiver 1, receiver 2, both receiver 1 and receiver 2, receiver
2 only when receiver 1 fails or no reporting at all.
Electronics Design and Manufacturing Pty Limited ISSUE140
LOCATION 336
\"91%&"'(
336
Solution 844/862/880
Installation Manual
?":751:(F$<700(L75"<%(
6
F709<&5%&"'(
Codepad Duress Report
Table 97: Codepad Duress Report Location
A "Duress" report (Contact ID Event Code 121) will be transmitted to the base station receiver when the
9
button is added to the end of any valid user code being used to disarm the system.
This alarm will always be silent. A duress alarm can be triggered during exit time (i.e.. If the system has been armed and then disarmed by adding the
9
button to the end of the user code before exit time has expired, a "Duress" report will be transmitted). Adding
9
to the end of a user code when arming the system will not cause a duress alarm.
Refer to Option 2 in “LOCATION 430” on page 235 if you wish to add the
3
button to the end of the user code being used to disarm the system.
Restore reports are not transmitted for this event. If a "Duress" report is not required, program "LOCATION 336" with a zero.
LOCATION 337 - 338
?":751:(K1'&9(L75"<%(
7
\"91%&"'(
337
338
F709<&5%&"'(
Codepad Panic Reporting Code (Tens Digit)
Codepad Panic Reporting Code (Units Digit)
Table 98: Codepad Panic Report Locations
A "Panic Alarm" report (Contact ID Event Code 120) will be transmitted to the base station receiver when either the two outside buttons
1
and
3
or and are pressed simultaneously. This is an audible alarm. Refer to Option 1 in "LOCATION 425" on page
230 if you require codepad panic to be silent.
Restore reports are not transmitted for this event. If a "Panic" report is not required, program "LOCATION 337 - 338" with a zero.
ISSUE140 Electronics Design and Manufacturing Pty Limited
System Reporting Information
LOCATION 339 - 340
193
?":751:(@&<7(L75"<%(
7
\"91%&"'(
339
340
F709<&5%&"'(
Codepad Fire Reporting Code (Tens Digit)
Codepad Fire Reporting Code (Units Digit)
Table 99: Codepad Fire Report Locations
A "Fire Alarm" report (Contact ID Event Code 110) will be transmitted to the base station receiver when the
4
and
6
buttons are pressed simultaneously. This is an audible alarm.
Refer to Option 2 in "LOCATION 425" on page 230 if you require codepad fire to be silent. A distinct fire sound is emitted through the horn speaker to indicate this type of alarm condition.
The fire sound is different to the burglary sound.
Restore reports are not transmitted for this event. If a "Fire" report is not required, program "LOCATION 339 - 340" with a zero.
LOCATION 341 - 342
\"91%&"'(
341
342
F709<&5%&"'(
Codepad Medical Reporting Code (Tens Digit)
Codepad Medical Reporting Code (Units Digit)
Table 100: Codepad Medical Report Locations
?":751:(27:&91#(L75"<%(
7
A "Medical" report (Contact ID Event Code 100) will be transmitted to the base station receiver when the
7
and
9
buttons are pressed simultaneously. This is an audible alarm.
Refer to Option 4 in "LOCATION 425" on page 230 if you require codepad medical to be silent.
Restore reports are not transmitted for this event. If a "Medical" report is not required, program "LOCATION 341 - 342" with a zero.
Electronics Design and Manufacturing Pty Limited ISSUE140
LOCATION 343
Solution 844/862/880
Installation Manual
?":751:(L75"<%&'6(>5%&"'0(
1
>5%&"'(
0
1
2
4
8
F709<&5%&"'(
No Report Required
Receiver 1
Receiver 2
Receiver 1 and Receiver 2
Receiver 2 Only When Receiver 1 Fails
Table 101: Codepad Reporting Options Location
This location is factory default to report only to receiver 1. You can select whether the codepad reporting options will report on receiver 1, receiver 2, both receiver 1 and receiver 2, receiver 2 only when receiver 1 fails or no reporting at all.
LOCATION 344 - 345
\"91%&"'(
344
345
!=0%7G(!%1%$0(c(@$07(@1&#(L75"<%(
3
F709<&5%&"'(
System Status – Fuse Fail Reporting Code (Tens Digit)
System Status – Fuse Fail Reporting Code (Units Digit)
Table 102: System Status – Fuse Fail Report Locations
A system trouble report (Contact ID Event Code 300) will be transmitted when either the codepad fuse or the accessories fuse has blown. A delay of approximately 10 seconds will be between from when the fuse has blown and when the system will report the event.
LOCATION 346 - 347
\"91%&"'(
346
347
!=0%7G(!%1%$0(c(@$07((@1&#(L70%"<7(L75"<%(
8
F709<&5%&"'(
System Status – Fuse Fail Restore Reporting Code (Tens Digit)
System Status – Fuse Fail Restore Reporting Code (Units Digit)
Table 103: System Status – Fuse Fail Restore Report Locations
A system trouble restore report (Contact ID Event Code 300) will be transmitted when either the codepad fuse or the accessories fuse has been replaced. A delay of approximately 10 seconds will be between from when the fuse has been replaced and when the system will report the event.
ISSUE140 Electronics Design and Manufacturing Pty Limited
System Reporting Information
LOCATION 348 - 349
\"91%&"'(
348
349
195
!=0%7G(!%1%$0(c(T?(@1&#(L75"<%(
2
F709<&5%&"'(
System Status – AC Fail Reporting Code (Tens Digit)
System Status – AC Fail Reporting Code (Units Digit)
Table 104: System Status – AC Fail Report Locations
An "AC Loss" report (Contact ID Event Code 301) will be transmitted to the base station receiver when the AC mains supply has been disconnected for two minutes. If you require an
"AC Loss" report to be transmitted to the base station receiver when the AC mains supply has been disconnected for 1 hour, enable Option 1 in "LOCATION 426" on page 231. If you wish to ignore AC fail, enable Option 2 in "LOCATION 426" on page 231.
If an "AC Loss" report is not required, program "LOCATION 348 - 349" with a zero.
LOCATION 350 - 351
\"91%&"'(
350
351
!=0%7G(!%1%$0(c(T?(@1&#(L70%"<7(L75"<%(
7
F709<&5%&"'(
System Status – AC Fail Restore Reporting Code (Tens Digit)
System Status – AC Fail Restore Reporting Code (Units Digit)
Table 105: System Status – AC Fail Restore Report Locations
A restore signal will be transmitted when the AC mains supply has been restored continuously for more than two minutes.
If an "AC Loss” restore report is not required, program "LOCATION 350 - 351" with a zero.
Electronics Design and Manufacturing Pty Limited ISSUE140
LOCATION 352 - 353
\"91%&"'(
352
353
Solution 844/862/880
Installation Manual
!=0%7G(!%1%$0(Y(\"D(V1%%7<=(L75"<%(
1
F709<&5%&"'(
System Status – Low Battery Reporting Code (Tens Digit)
System Status – Low Battery Reporting Code (Units Digit)
Table 106: System Status – Low Battery Report Locations
A "Battery Test Failure" report (Contact ID Event Code 309) will be transmitted to the base station receiver when the systems battery voltage falls below 10.5 volts or when a dynamic battery test detects a low capacity battery.
The control panel continually monitors the battery voltage. Refer to Fault Descriptions on page 74 for more information. A dynamic battery test is performed every time the system has been armed as well as every four hours from power up of the control panel.
If a "Low Battery" report is not required, program "LOCATION 352 - 353" with a zero.
Outputs 1 – 4 will NOT operate whilst the control panel detects a low battery.
LOCATION 354 - 355
\"91%&"'(
354
355
!=0%7G(!%1%$0(Y(\"D(V1%%7<=(L70%"<7(L75"<%(
6
F709<&5%&"'(
System Status – Low Battery Restore Report (Tens Digit)
System Status – Low Battery Restore Report (Units Digit)
Table 107: System Status – Low Battery Restore Report Locations
A "Low Battery” restore report will be transmitted if the back up battery has been restored the next time the system has been armed, or when the next dynamic battery test reports the battery test is OK.
If a "Low Battery Restore" report is not required, program "LOCATION 354 - 355" with a zero.
ISSUE140 Electronics Design and Manufacturing Pty Limited
System Reporting Information
LOCATION 356 - 358
\"91%&"'(
356
357
358
197
!=0%7G(!%1%$0(Y(T99700(F7'&7:(
6 7
F709<&5%&"'(
Code Retries (0–15)
System Status – Access Denied Reporting Code (Tens Digit)
System Status – Access Denied Reporting Code (Units Digit)
Table 108: System Status – Access Denied Locations
An "Access Denied" report (Contact ID Event Code 421) will be transmitted to the base station receiver when the number of incorrect code attempts equals the number programmed in
"LOCATION 356". This is an audible alarm. Refer to Option 8 in "LOCATION 425" on page
230 if you require this alarm to be silent.
Restore signals for this event are not transmitted. If an "Access Denied" report is not required, program "LOCATION 357 - 358" with a zero.
?":7(L7%<&70(
Code retries restricts the amount of times an invalid user code can be used in an attempt to operate the system. This location sets the number of incorrect code attempts that will cause an alarm condition. When the number of incorrect code attempts equals the number programmed in this location, the system will carry out the following;
1.
2.
3.
Activate the sirens, internal screamers and strobes connected to the control panel. Refer to Option 8 in “LOCATION 425” on page 230 if you require access denied to be silent.
Shutdown all codepads that are connected to the control panel and lock them out for the time period programmed in “LOCATION 410” on page 220.
Transmit an “Access Denied” (Contact ID Event Code 421) report to the base station receiver.
Each time the system is armed or disarmed, the counter will be reset. The number of attempts can be anywhere between 1-15. If you program a zero into “LOCATION 356”, the code attempts are unlimited and neither of the three points listed above will take place. This function works when the system is in the armed or disarmed state.
Electronics Design and Manufacturing Pty Limited ISSUE140
LOCATION 359
Solution 844/862/880
Installation Manual
!=0%7G(!%1%$0(L75"<%&'6(>5%&"'0(
1
>5%&"'(
0
1
2
4
8
No Report Required
Receiver 1
F709<&5%&"'(
Receiver 2
Receiver 1 and Receiver 2
Receiver 2 Only When Receiver 1 Fails
Table 109: System Status Reporting Options Location
This location is factory default to report only to receiver 1. You can select whether the system status reporting options will report on receiver 1, receiver 2, both receiver 1 and receiver 2, receiver 2 only when receiver 1 fails or no reporting at all.
ISSUE140 Electronics Design and Manufacturing Pty Limited
System Reporting Information
LOCATION 360 - 366
\"91%&"'(
360
361
362
363
364
365
366
199
370%(L75"<%&'6(3&G7(
0000 71 0
F709<&5%&"'(
Actual Hour Of The Day (Tens Digit)
Actual Hour Of The Day (Units Digit)
Actual Minute Of The Day (Tens Digit)
Actual Minute Of The Day (Units Digit)
Test Report Code (Tens Digit)
Test Report Code (Units Digit)
Repeat Interval In Days
Table 110: Test Reporting Time Locations
A "Test" report (Contact ID Event Code 602) is a specific signal that is transmitted to the base station receiver and is normally used to test the dialling and reporting functions of the control panel. Test reports will not be transmitted if the Subscriber ID Number is 0000.
When programming test reports, the control panel needs to know the hour and minute of the day the report is required, as well as how often to transmit the report. Test reports are reported on a daily basis ranging from every day to every fifteen days. Refer to "Installer Code
Functions" on page 86 to set the first test report.
If you do not require "Test" reports, program the repeat interval in "LOCATION 366" as zero.
HI1G5#7(
If you wish to send test reports once every seven days at 11:35 PM, you would program
“LOCATION 360 - 366” as follows:
2335 71 7
LOCATION 367
>5%&"'(
0
1
2
4
8
370%(L75"<%&'6(F&1##7<(>5%&"'0(
1
F709<&5%&"'(
No Report Required
Receiver 1
Receiver 2
Receiver 1 and Receiver 2
Receiver 2 Only When Receiver 1 Fails
Table 111: Test Reporting Options Location
This location is factory default to report only to receiver 1. You can select whether the test reporting options will report on receiver 1, receiver 2, both receiver 1 and receiver 2, receiver 2 only when receiver 1 fails or no reporting at all.
Electronics Design and Manufacturing Pty Limited ISSUE140
Solution 844/862/880
Installation Manual
ISSUE140 Electronics Design and Manufacturing Pty Limited
K<"6<1GG18#7(>$%5$%0(
>$%5$%0(
ISSUE140
Solution 844/862/880
Installation Manual
The
Solution 844/862/880
control panel has four fully programmable outputs on the main PCB and one other programmable output that operates the codepad buzzer. These four outputs are factory default to operate a horn speaker, fire alarm verification, strobe and an internal screamer.
Outputs 1 – 4 will NOT operate whilst the control panel detects a low battery.
Programmable outputs require four parameters to be programmed in order to operate correctly.
HM7'%(3=57i
K"#1<&%=i
When To Operate
How To Operate
3&G7(V107i
How Long To Operate For
3&G7(2$#%&5#&7<i
How Often To Operate
HM7'%(
3=57(
K"#1<&%=( 3&G7(
V107(
3&G7(
2$#%&5#&7<(
O47'(3"(>57<1%7
Is selected from the output event types listed on page 204.
Each digit should be entered into the two corresponding locations for the output event type required.
C"D(3"(>57<1%7
Is selected from "Table 112: Event Type Polarities” on page
213. This determines whether the output remains operating for the duration of the event, pulses for the duration, operates once only (one shot) or latches on.
C"D(\"'6(3"(>57<1%7(@"<
Is determined by a time base and a multiplier. Refer to
"Timing Of Outputs" on page 215 for further information.
C"D(>;%7'(3"(>57<1%7(@"<
Is determined by a time base and a multiplier. Refer to
"Timing Of Outputs" on page 215 for further information.
>$%5$%(F7;1$#%0(
>$%5$%(N
L7#1=(
Location 368 - 373
N( N*( .( .( .( .(
Default For Horn
Speaker
Location 386 – 391
N( NR( N( .( .( .(
Default For
Sirens Running
>$%5$%(-
Location 374 - 379
-( S( N.( -( N( R(
?":751:(
Default For
Fire Alarm Verification
Location 392 – 397
.( NQ( -( N( .( N(
Default For Entry/Exit
Warning + Day Alarm
!%<"87
(
Location 380 - 385
-( .( ,( *( .( )(
Default For Strobe
(Reset In 8 Hrs)
( ( ( ( ( (
HM7'%(3=57( K"#1<&%=( 3&G7(V107( 3&G7(2$#%&5#&7<(
Electronics Design and Manufacturing Pty Limited
Programmable Outputs 203
L7:&<79%&'6(>$%5$%0(3"(347(?":751:(V$dd7<(
Multiple output event types can be directed to the codepad buzzer so that it may be used to indicate any number of events.
This is achieved by selecting an output and programming it for the required output event type.
When you are satisfied that the output is functioning correctly, change the first digit of the output event type (i.e.. The tens digit) by adding the value 8.
HI1G5#7(
30
Communications Failure
This event will operate when the dialler has made all possible attempts to reach the base station receiver. The output will reset when the first "Kiss-Off" is received.
This output event type is not applicable for domestic reporting.
To redirect the above output event type to operate a codepad buzzer, program the output event type as below:
0
Communications Failure
This event will operate when the dialler has made all possible attempts to reach the base station receiver. The output will reset when the first "Kiss-Off" is received.
This output event type is not applicable for domestic reporting.
The codepad buzzer will now operate instead of the output that has been programmed. The output is no longer functional and cannot be used for any other output event type.
Electronics Design and Manufacturing Pty Limited ISSUE140
ISSUE140
Solution 844/862/880
Installation Manual
>$%5$%(HM7'%(3=570(
There are approximately seventy five different output event types to choose from. Two numbers designate each output event type. These two numbers need to be programmed into the appropriate locations of the output being used to indicate when the output should operate.
All reset times are in reference to polarity 1 and 8. Reset times will vary depending on the polarity used.
00
EDMSAT - Satellite Siren (Output 1 Only)
This output controls all functions of an EDMSAT satellite siren (SS914). The option of speaker indication beeps will not operate via the EDMSAT for remote operations. No polarity is required to be programmed for this output event type.
01
System Armed
This output will operate when the system is armed in AWAY Mode, STAY Mode 1 or STAY Mode 2. The output will reset when the system has been disarmed.
02
System Disarmed
This output will operate when the system is in the disarmed state. The output will reset as soon as the system becomes armed.
03
Armed In STAY Mode
This output will operate when the system has been armed in STAY Mode 1 or
STAY Mode 2. The output will reset when the system is disarmed.
04
Armed In AWAY Mode
This output will operate when the system has been armed in AWAY Mode. The output will reset when the system is disarmed.
05
Auto Arm Pre-Arming Alert Time
This output will operate during the time period before the control panel will automatically arm in AWAY Mode or STAY Mode 1. Once the control panel has automatically armed in AWAY Mode or STAY Mode 1, the output will reset. To program the pre-arming alert time, refer to “LOCATION 413” on page 222.
06
Exit Warning With All Zones Sealed Or Entry Warning
This output will operate during exit time when the control panel has been armed in
AWAY Mode, STAY Mode 1 or STAY Mode 2 if all zones are sealed. This output event type will reset once exit time has expired.
The next time this output event type will operate will be during entry time and will reset once entry time has expired or the system has been disarmed. This output event type will also operate if a zone has triggered when the system has been armed in STAY Mode 1 or STAY Mode 2 only if the Entry Guard Timer For STAY Mode has been programmed in "LOCATION 404 - 405" on page 219.
07
Exit Warning
This output operates during exit time when the system has been armed in AWAY
Mode, STAY Mode 1 or STAY Mode 2. The output will reset once exit time has expired.
Electronics Design and Manufacturing Pty Limited
Programmable Outputs 205
08
Exit Warning Finished
This output operates when the exit time has expired when the system has been armed in AWAY Mode, STAY Mode 1 or STAY Mode 2. The output will reset when the system has been disarmed.
09
Kiss-Off After Exit Time
This output will operate after the first successful transmission to the base station receiver when exit time has expired. The output will reset when the system has been disarmed.
0
Entry Warning
This output will operate when either Entry Timer 1, Entry Timer 2 or Entry Guard
Timer For STAY Mode are operating. The output will reset when the entry time expires.
0
Entry Warning + Day Alarm Resetting
This output combines both Entry Warning and Day Alarm Resetting so that either of these two events will activate the output.
If the output has been triggered by either Entry Timer 1, Entry Timer 2, or Entry
Guard Timer For STAY Mode, the output will reset once the entry timer has expired or the system has been disarmed.
If a zone programmed for day alarm has triggered during the disarmed state, the output will reset when the zone has resealed. Day alarm may be turned on and off by holding down the
4
button. Refer to Day Alarm Zones on page 168 for programming zones to operate for day alarm.
0
Exit Warning + Entry Warning + Day Alarm Resetting
This output combines exit warning, entry warning and day alarm so that any of these three events will activate the output.
This output will activate once the system has been armed in AWAY Mode, STAY
Mode 1 or STAY Mode 2 irrespective of any zones being sealed or unsealed until exit time expires.
The next time the output will activate will be during entry time and will reset once entry time has expired or the system has been disarmed. This output will also operate when the Entry Guard Timer For STAY Mode is timing.
If a zone programmed for day alarm has triggered during the disarmed state, the output will reset when the zone has resealed. Day alarm may be turned on and off by holding down the
4
button. Refer to Day Alarm Zones on page 168 for programming zones to operate for day alarm.
0
Day Alarm Resetting
This output will operate when a zone programmed for day alarm has been triggered.
The output will reset when the day alarm zone has resealed. Day alarm may be turned on and off by holding down the
4
button. Refer to Day Alarm Zones on page 168 for programming zones to operate for day alarm.
0
Day Alarm Latching
This output will operate when a zone programmed for day alarm has been triggered.
The output will reset when the button has been pressed. Day alarm may be turned on and off by holding down the
4
button. Refer to Day Alarm Zones on page 168 for programming zones to operate for day alarm.
Electronics Design and Manufacturing Pty Limited ISSUE140
ISSUE140
Solution 844/862/880
Installation Manual
10
Day Alarm Enabled
This output will operate as soon as day alarm has been enabled. The output will reset when day alarm has been turned off.
Day alarm can be turned on and off by holding down the
4
button. Three beeps indicates that day alarm has been turned on, two beeps indicates that day alarm has been turned off. Refer to Day Alarm Zones on page 168 for programming zones to operate for day alarm.
11
Telephone Line Fail
This output will operate when the in-built telephone line fault module detects that the telephone line has been disconnected for a period of approximately 40 seconds.
The output will reset once the telephone line has been restored continuously for more than 40 seconds. This output will not operate unless Option 1 in “LOCATION
176” on page 153 has been enabled.
12
Kiss-Off Received
This output will operate after the control panel has successfully transmitted to the receiving party.
13
Fuse Fail
This output will operate when either the 1 Amp codepad fuse or the 1 Amp accessories fuse fails. The output will reset once the faulty fuse has been replaced.
14
AC Fail
This output will operate as soon as the AC mains has failed. The output will reset as soon as the AC mains has restored. This output will operate regardless of Option 2 in "LOCATION 426" on page 231 being set.
15
Low Battery
This output will operate when a dynamic battery test detects that the battery has failed or the battery voltage has fallen below 10.5 volts. The dynamic battery test is performed every four hours from when the system has been powered up or every time the system has been armed in AWAY Mode, STAY Mode 1 or STAY Mode 2.
This output will reset only after a dynamic battery test reports the backup battery has restored.
16
Horn Speaker Monitor Fail
If Option 2 – Enable Monitoring Of Horn Speaker in "LOCATION 424" on page
229 has been selected, this output will operate when the horn speaker has been disconnected. The output will reset when the horn speaker has been reconnected.
17
Sensor Watch Alarm
This output will operate when the sensor watch count has been reached. Refer to
Zone Options 1 on page 179 for more information on programming zones for sensor watch. Refer to "LOCATION 408 - 409" on page 220 for setting how many days before a zone can register as a faulty sensor watch zone.
18
Codepad Medical Alarm
This output will operate when a codepad medical alarm has been activated by pressing the
7
and
9
buttons simultaneously on the remote codepad. This output will reset once a valid user code has been entered at the remote codepad.
Electronics Design and Manufacturing Pty Limited
Programmable Outputs 207
19
Codepad Fire Alarm
This output will operate when a codepad medical alarm has been activated by pressing the
4
and
6
buttons on the remote codepad simultaneously. This output will reset once a valid user code has been entered at the remote codepad.
1
Codepad Panic Alarm
This output will operate when a codepad panic alarm (audible or silent) has been activated by pressing the
1
and
3
buttons or the and buttons on the remote codepad simultaneously. This output will reset once a valid user code has been entered at the remote codepad.
1
Codepad Duress Alarm
This output will operate when a duress alarm has been activated by adding a
9
to the end of the user code being used to disarm the system. This output will reset the next time the system has been armed.
1
Codepad Tamper – Access Denied
This output will operate when the wrong code has been entered more times than allowed. Refer to "LOCATION 356" on page 197 for setting the number of incorrect attempts that may be allowed. This output will reset once a valid user code has been entered.
1
Horn Speaker (Output 1 Only)
This output will operate only on Output 1 and should be programmed whenever an 8 ohm horn speaker is required. A maximum of two horn speakers may be used.
Refer to “LOCATION 411” on page 221 for setting the siren run time and
“LOCATION 412” on page 221 for setting the siren sound rate.
If you require monitoring of the horn speaker, refer to Option 2 in “LOCATION
424” on page 229.
1
Sirens Running
This output will operate for the duration of the siren run time programmed in
"LOCATION 411" on page 221. When the sirens have been activated, this output will reset once the siren run time has expired. The relay output (Output 4) is factory default for this operation.
20
Strobe Operating
This output will operate when an alarm condition occurs and will reset once a valid user code has been entered. The strobe output (Output 3) is factory default for this operation and is programmed to automatically reset after 8 hours of duration.
21
Silent Alarm
This output will operate when any zone programmed to be silent alarm has triggered. The output will reset when the siren run time expires, an audible alarm has triggered, or a valid user code has been entered.
22
Alarm When In STAY Mode
This output will operate whenever an audible or silent zone alarm has triggered when the system has been armed in STAY Mode 1 or STAY Mode 2. The output will reset when the system has been disarmed.
Electronics Design and Manufacturing Pty Limited ISSUE140
Solution 844/862/880
Installation Manual
23
Alarm When In AWAY Mode
This output will operate whenever an audible or silent zone alarm has triggered when the system has been armed in AWAY Mode. The output will reset when the system has been disarmed.
24
Mimic System Fault
This output will operate without any time delays as soon as any system fault occurs including if the AC mains supply has failed. The output will reset as soon as the system fault or the AC mains supply has restored.
25
Fire Alarm Resetting
This output will operate when a 24 hour fire zone is triggered. The output will reset once a valid user code has been entered or when siren run time expires.
26
Fire Alarm Latching
This output will operate when a 24 hour fire zone has triggered and will reset when the system has been armed or disarmed.
27
Fire Alarm Verification
This feature is used on some commercial fire control panels to reduce false alarms on smoke detectors. It is conceptually very similar to zone pulse count as used in some motion detectors. Basically, a fire zone is allotted a pulse count of 3 pulses over a period of 3 minutes.
If the smoke detector trips, the voltage to the smoke detector is disconnected for 15 seconds and then reapplied. No alarm has registered.
If within 3 minutes of the first trigger the unit triggers again, no alarm will be registered and the voltage to the smoke detector will again be disconnected for 15 seconds and then reapplied.
If a third trigger is detected within 3 minutes of the first trigger, (i.e.. 3 pulses in 3 minutes) a fire alarm will be registered. Power to the smoke detector will be maintained to facilitate unit identification via the detector memory.
This output should be connected to the negative side of any fire/smoke detector. To configure an output for this feature, use the following settings.
EVENT TYPE = 2,7 POLARITY = 10
TIMEBASE = 2 MULTIPLIER = 15
The zone that the fire/smoke detector is connected to should be programmed as follows:
ZONE TYPE = 13 ZONE PULSE COUNT = 3
ZONE PULSE COUNT TIME = 15
ISSUE140 Electronics Design and Manufacturing Pty Limited
Programmable Outputs 209
28
Remote Control 1
2
29
Remote Control 2
Remote Control 3
These outputs can be remotely activated (Turned "On" or "Off") via the following methods:
1.
Remote Codepad - Refer to the Master Code Functions - “Turning Outputs
On/Off” on page 112 for further information.
2.
Remotely Via Alarm Link Software - Refer to your Alarm Link Instruction
Manual for further information.
2
Radio Control Output 1
This output will operate when the button marked DOOR on the 4 channel hand held transmitter is activated when the system is armed or disarmed.
2
Radio Control Output 2
This output will operate when the button marked AUX on the 4 channel hand held transmitter is activated when the system is armed or disarmed.
2
Radio Control Output 1 – Not In AWAY Mode
This output will operate when the button marked DOOR on the 4 channel hand held transmitter is activated when the system is disarmed or armed in STAY Mode 1 or
STAY Mode 2. The output will not operate when the system is armed in AWAY
Mode
2
Radio Control Output 2 – Not In AWAY Mode
This output will operate when the button marked AUX on the 4 channel hand held transmitter is activated when the system is disarmed or armed in STAY Mode 1 or
STAY Mode 2. The output will not operate when the system is armed in AWAY
Mode.
2
Communications Failure After 3 Unsuccessful Calls
This output will operate when the communication dialler has made 3 unsuccessful calls to the base station receiver. The output will reset when all messages have been transmitted (i.e.. When the buffer is empty or when all possible attempts have been made).
30
Communications Failure
This output will operate when the communication dialler has made all possible attempts to reach the base station receiver. The output will reset when the first
"Kiss-Off" has been received. This output will not operate for domestic formats.
31
Dialler Disabled
This output will operate as long as Option 1 in "LOCATION 177" on page 157 has been disabled. The output will reset once Option 1 – Enable Dialler Reporting
Functions in "LOCATION 177" on page 157 has been enabled.
32
Dialler Active
This output will operate when the communication dialler is on-line. The output will reset when the communication dialler has released the telephone line.
33
Ring Detect
This output will operate when an incoming call has been detected by the control panel. The output will reset when the ringing has stopped or when the call has been answered.
Electronics Design and Manufacturing Pty Limited ISSUE140
Solution 844/862/880
Installation Manual
35
Mimic Zone 1
39
Mimic Zone 5
36
38
Mimic Zone 2
37
Mimic Zone 3
3
Mimic Zone 6
3
Mimic Zone 7
Mimic Zone 4
3
Mimic Zone 8
These output types will mimic the zone inputs. The output will operate when the zone is unsealed and will reset when the zone has resealed. They will operate regardless of the zone type chosen (i.e.. A zone "Not Used" can still operate a mimic output). This feature operates when the system is armed or disarmed.
45
Global Chime
This output will operate when any zones programmed as "Chime" have triggered.
The output will reset when the zone has resealed. Refer to Zone Type on page 173 for more information.
46
Zone Not Sealed
This output will operate whenever a burglary zone is unsealed. Chime zones will not operate this output event type.
47
Zone Not Sealed After Exit Time
This output will operate at the end of exit time if a burglary zone is unsealed. The output will reset when all zones are sealed or the system has been disarmed. Chime zones will not operate this output event type.
49
AC Mains 60 Hz Or 50 Hz
This output will activate when the AC mains supply frequency is at 60 Hz. The output will reset once the AC mains supply has returned to 50 Hz.
ISSUE140 Electronics Design and Manufacturing Pty Limited
Programmable Outputs
347(;"##"D&'6("$%5$%(7M7'%(%=570(1<7("'#=(155#&918#7(%"(%47(!"#$%&"'()).(9"'%<"#(51'7#(D47'(51<%&%&"'7:j(
211
4
Area 1 Has Zone Unsealed
4
Area 2 Has Zone Unsealed
These two outputs will operate when a zone in their corresponding area has registered as unsealed when the area is either armed in AWAY Mode or STAY
Mode, or the area is disarmed.
HI1G5#7(
Zone 1 is allocated to Area 1. If Zone 1 becomes unsealed, Output Event Type 4,10 will operate. The output will reset once the zone has resealed.
52
Area 1 In Alarm
53
Area 2 In Alarm
These two outputs will operate when a zone in their corresponding area has registered an alarm. These outputs will reset once a valid user code has been entered.
HI1G5#7(
Zone 1 has been allocated to Area 1. If Zone 1 has registered an alarm, Output
Event Type 5,2 will operate. The output will reset once a valid user code allocated to operate Area 1 has been entered.
56
Area 1 Is Armed
57
Area 2 Is Armed
These two outputs will operate when their corresponding area has been armed in
AWAY Mode or STAY Mode 1. The output will reset once the corresponding area is disarmed.
HI1G5#7(
If area 1 has been armed in AWAY Mode or STAY Mode 1, Output Event Type 5,6 will operate. The output will reset once Area 1 is disarmed.
5
Area 1 Is Disarmed
5
Area 2 Is Disarmed
These two outputs will operate when their corresponding area has been disarmed.
The output will reset once the corresponding area is armed.
HI1G5#7(
If Area 1 has been disarmed, Output Event Type 5,10 will operate. The output will reset once Area 1 is disarmed.
5
Any Areas Armed
This output will operate when either Area 1 or Area 2 has become armed in AWAY
Mode or STAY Mode 1. The output will reset when both areas are disarmed.
5
Any Areas Disarmed
This output will operate when either Area 1 or Area 2 has become disarmed. The output will reset when both areas are armed in either AWAY Mode or STAY Mode
1.
Electronics Design and Manufacturing Pty Limited ISSUE140
Solution 844/862/880
Installation Manual
60
Area 1 Codepad Data Terminal
This output type is used to connect the data terminal of the Area 1 codepad when you are using the Master Partitioned codepad as the main codepad. Set DIP switch 1 in the ON position for the Area 1 codepad to operate correctly. Refer to Figure 12:
DIP Switch Location On Back Of Codepad PCB below for the location of the DIP switches on the pack of the codepad.
If you are not using a Master Partitioned as the main codepad, connect the data cable from the Area 1 codepad to the DATA terminal on the control panel and enable
Option 2 in “LOCATION 432” on page 243.
Refer to Codepad Connections For Partitioning on page 249 for further information on connecting codepads when the system has been partitioned.
61
Area 2 Codepad Data Terminal
This output type is used to connect the data terminal of the Area 2 codepad. Set DIP
Switch 2 to the ON position for the Area 2 codepad to operate correctly. Refer to
Figure 12: DIP Switch Location On Back Of Codepad PCB below for the location of the DIP switches on the back of the codepad.
Figure 12: DIP Switch Location On Back Of Codepad PCB
ISSUE140 Electronics Design and Manufacturing Pty Limited
Programmable Outputs
3
4
5
6
7
>5%&"'(
0
1
2
213
>$%5$%(K"#1<&%=(
There are fifteen different polarities to choose from. Each polarity is designated by a number.
This number needs to be programmed into the appropriate location of the output being used to indicate how the output should operate.
K"#1<&%=(
Output Not Used
Normally Open, Going Low
Normally Open, Pulsing Low
Normally Open, One Shot Low
Normally Open, One Shot Low (Retrigger)
Normally Open, One Shot Low (Can Reset)
Normally Open, One Shot Low (Alarm)
Normally Open, Latching Low
>5%&"'(
8
9
10
11
12
13
14
Table 112: Event Type Polarities
K"#1<&%=(
Normally Low, Going Open
Normally Low, Pulsing Open
Normally Low, One Shot Open
Normally Low, One Shot Open (Retrigger)
Normally Low, One Shot Open (Can Reset)
Normally Low, One Shot Open (Alarm)
Normally Low, Latching Open
.(
N(
-(
Q(
*(
R(
>$%5$%(E"%(Z07:( (
If an output is not required for use, the polarity should be programmed as zero.
E"<G1##=(>57'f(_"&'6(\"D(
This polarity is normally open circuit and will switch to zero volts when the event occurs. The output will switch back to open circuit when the event has restored. Time parameters are not applicable to this polarity.
E"<G1##=(>57'f(K$#0&'6(\"D(
This polarity is normally open circuit and will switch to pulsing zero volts when the event occurs. The output will switch back to open circuit when the event has restored. Time parameters vary the "On" time of the pulse.
E"<G1##=(>57'f(>'7(!4"%(\"D(
This one shot polarity is normally open circuit and will switch to zero volts when the event occurs. The output will switch back to open circuit when the time parameter setting has expired. This one shot time setting will always run its full duration and cannot be manually reset.
E"<G1##=(>57'f(>'7(!4"%(\"D(O&%4(L7%<&667<(
This one shot polarity is normally open circuit and will switch to zero volts when the event occurs. Every time the event occurs, it will restart the one shot timer. The output will switch back to open circuit once the one shot time has expired.
This polarity is ideally suited for lighting control. A PIR can be used to trigger an output for turning on lights. While ever there is movement, the PIR will keep re-triggering the output and lengthen the time the lights will remain switched on.
E"<G1##=(>57'f(>'7(!4"%(\"D(O&%4(L707%(
This one shot polarity is normally open circuit and will switch to zero volts when the event occurs. The output will switch back to open circuit when the one shot time has expired or when the event has returned to normal. This means the operation of the output can be shortened regardless of the time parameter programmed.
Electronics Design and Manufacturing Pty Limited ISSUE140
ISSUE140
,(
S(
)(
X(
N.(
NN(
N-(
NQ(
N*(
Solution 844/862/880
Installation Manual
E"<G1##=(>57'f(>'7(!4"%(\"D(O&%4(T#1<G(
This one shot polarity is normally open circuit and will switch to zero volts when the event occurs. The output will switch back to open circuit once the one shot time has expired, when the event has returned to normal or when the system has been disarmed.
This polarity is ideally suited for the operation of strobe lights as they can be programmed (Up to 99 hours) to reset and prevent them from burning out or becoming annoying to others from prolonged operation.
E"<G1##=(>57'f(\1%94&'6(\"D(
This polarity is normally open circuit and will switch to zero volts when the event occurs. The output will switch back to open circuit once the
7
button on the remote codepad is held down until two beeps are heard. Time parameters are not applicable to this polarity.
E"<G1##=(\"Df(_"&'6(>57'(
This polarity is normally zero volts and will switch to open circuit when the event occurs. The output will switch back to zero volts when the event has restored. Time parameters are not applicable to this polarity.
E"<G1##=(\"Df(K$#0&'6(>57'(
This polarity is normally zero volts and will switch to pulsing open circuit when the event occurs. The output will switch back to zero volts when the event has restored. Time parameters vary the "Off" time of the pulse.
E"<G1##=(\"Df(>'7(!4"%(>57'(
This one shot polarity is normally zero volts and will switch to open circuit when the event occurs. The output will switch back to zero volts when the time parameter has expired. This one shot time setting will always run its full duration and cannot be manually reset.
E"<G1##=(\"Df(>'7(!4"%(>57'(O&%4(L7%<&667<(
This one shot polarity is normally zero volts and will switch to open circuit when the event occurs. Every time the event occurs, it will restart the one shot timer. The output will switch back to zero volts once the one shot time has expired.
E"<G1##=(\"Df(>'7(!4"%(>57'(O&%4(L707%(
This one shot polarity is normally zero volts and will switch to open circuit when the event occurs. The output will switch back to zero volts when the one shot time has expired or when the event has returned to normal. This means the one shot timer can be shortened regardless of the time setting.
E"<G1##=(\"Df(>'7(!4"%(>57'(O&%4(T#1<G(
This one shot polarity is normally zero volts and will switch to open circuit when the event occurs. The output will switch back to zero volts when the one shot time has expired, when the event has returned to normal or when the system has been disarmed. This means that the one shot timer can be shortened regardless of the time setting.
E"<G1##=(\"Df(\1%94&'6(>57'(
This polarity is normally zero volts and will switch to open circuit when the event occurs. The output will switch back to zero volts once the
7
button on the remote codepad has been held down until two beeps are heard. Time parameters are not applicable to this polarity.
Electronics Design and Manufacturing Pty Limited
Programmable Outputs 215
3&G&'6(>;(>$%5$%0(
The timing of outputs is calculated by the time base and a multiplier. These two values play different roles depending on the polarity selected. When programming outputs to pulse, both the "On" and "Off" times can be set. One shot polarities can be programmed to operate between 200 ms up to 99 hours in duration.
3&G7((
V107(
2$#%&5#&7<(
37'0(+(Z'&%0(
The maximum value that can be programmed in the two multiplier locations is
99
.
>5%&"'(
1
2
3
4
3&G7(V107(
200 ms
1 Second
1 Minute (60 Seconds)
1 Hour (60 Minutes)
Table 113: Time Base Settings
The time base settings can be set to only one of the values listed in "Table 113: Time Base
Settings". The multiplier value is a two digit decimal number from 00-99. For greater accuracy, use 60 seconds for 1 minute intervals and use 60 minutes for one hour intervals.
K$#0&'6(K"#1<&%&70(
When calculating pulsing polarities both the "On" and "Off" times need to be programmed.
The duration or "On" time of an output is determined by selecting only one of the time base options from "Table 113: Time Base Settings". This means there are only four "On" times to choose from.
The "Off" time is calculated as a multiple of the "On" time by choosing a decimal number between 00 and 99. If an output is required to operate for 200 ms every five seconds, program the time settings as follows;
>E(3&G7(
200 ms
1 Sec
1 Min
1 Hour
( N( ( ( -( R( (
>'(3&G7( >;;(3&G7(
>@@(3&G7(
200 ms - 19.8 ms
1 Sec - 99 Sec’s
1 Min - 99 Min’s
1 Hour - 99 Hours
/'9<7G7'%0(
200 ms
1 Sec
1 Min
1 Hour
Table 114: Pulsing Time Settings
3"#7<1'97(
+/- 200 ms
+/- 1 Sec
+/- 1 Min
+/- 1 Hour
Electronics Design and Manufacturing Pty Limited ISSUE140
Solution 844/862/880
Installation Manual
>'7(!4"%(K"#1<&%&70(
The duration or "On" time of an output is determined by the product of the time base and the multiplier.
If an output is required to operate for five seconds, program the time settings as follows;
( -( ( ( .( R( (
3&G7(V107( 2$#%&5#&7<(
The "On" time is calculated by multiplying the time base setting (1 second) by the multiplier value (05).
(i.e.. 1 x 05 = 5 seconds)
>'(3&G7(
200 ms - 19.8 Sec’s
1 Sec - 99 Sec’s
1 Min - 99 Min’s
1 Hour - 99 Hours
/'9<7G7'%0(
200 ms
1 Sec
1 Min
1 Hour
Table 115: One Shot Time Settings
3"#7<1'97(
+/- 200 ms
+/- 1 Sec
+/- 1 Min
+/- 1 Hour
ISSUE140 Electronics Design and Manufacturing Pty Limited
!=0%7G(HM7'%(3&G7<0(
Solution 844/862/880
Installation Manual
!=0%7G(HM7'%(3&G7<0(
This section covers the features that involve timing. Features such as entry and exit times, sensor watch time, siren run time and system date and time along with a host of other timers are discussed extensively in this section.
K<"6<1GG&'6(H'%<=+HI&%(3&G7<0(
There are two locations to be programmed for Entry Timer 1, Entry Timer 2, Exit Time For
AWAY Mode and Entry Guard Time For STAY Mode.
The first location of the timer is for programming increments of 1 second. The second location of the timer is for programming increments of 16 seconds. By adding these two locations together will give the total time required.
HI1G5#7
If you require the entry time to expire after 18 seconds, you would need to program
“LOCATION 398” as 2 (i.e.. 2 x 1 second = 2 seconds) and “LOCATION 399” as 1 (i.e.. 1 x
16 seconds = 16 seconds). This would give you the total time of 18 seconds (i.e.. 2 + 16 seconds = 18 seconds.
H'%<=(3&G7<(N(
LOCATION 398 - 399
(Defaulted To 20 Seconds
41
\"91%&"'( F709<&5%&"'(
398
Increments Of 1 Second (0 – 15 Sec’s)
399
Increments Of 16 Seconds (0 – 240 Sec’s)
Table 116: Entry Timer 1 Locations
Entry time can be programmed between 0 and 255 seconds in increments of one second. Entry
Timer 1 is the delay time used by the zone type – Delay-1. Refer to Zone Types on page 175 for more information.
H'%<=(3&G7<(-(
82
LOCATION 400 - 401
(Defaulted To 40 Seconds)
\"91%&"'(
400
401
F709<&5%&"'(
Increments Of 1 Second (0 - 15 Sec’s)
Increments Of 16 Seconds (0 –240 Sec’s)
Table 117: Entry Timer 2 Locations
Entry time can be programmed between 0 and 255 seconds in increments of one second. Entry
Timer 2 is the delay time used by the zone type – Delay-2. Refer to Zone Types on page 175 for more information.
ISSUE140 Electronics Design and Manufacturing Pty Limited
System Event Timers 219
F709<&5%&"'(
Increments Of 1 Second (0 - 15 Sec’s)
Increments Of 16 Seconds (0 –240 Sec’s)
HI&%(3&G7(
3
LOCATION 402 – 403
(Defaulted To 60 Seconds)
\"91%&"'(
402
403
Table 118: Exit Time Locations
Exit time can be programmed between 0 and 255 seconds in increments of one second. When arming the system in AWAY Mode, the remote codepad will beep during exit time until the remaining 10 seconds where the codepad will give you one continuous beep to inform you that the end of exit time is approaching.
The remote codepad will always give one short beep at the end of exit time when arming in
STAY Mode 1 or STAY Mode 2.
H'%<=(_$1<:(3&G7<(@"<(!3T](2":7(
00
LOCATION 404 - 405
(Defaulted To 00 Seconds)
\"91%&"'(
404
405
F709<&5%&"'(
Increments Of 1 Second (0 - 15 Sec’s)
Increments Of 16 Seconds (0 –240 Sec’s)
Table 119: Entry Guard Timer For STAY Mode Locations
"Entry Guard Timer For STAY Mode" is the delay time used for ALL zones except 24 hour burglary and 24 hour fire zones when the system is armed in STAY Mode 1 or STAY Mode 2.
Each zone including delay zones will have the entry delay as programmed in "LOCATION 404
- 405" (i.e.. The entry guard timer will override the delay time programmed for a delay zone).
If the entry guard timer has been programmed as "0" each zone will act as per its programmed zone type.
F7#1=(T#1<G(L75"<%&'6(3&G7(
00
LOCATION 406 – 407
(Defaulted To 00 Seconds)
\"91%&"'(
406
407
F709<&5%&"'(
Increments Of 1 Second (0 - 15 Sec’s)
Increments Of 16 Seconds (0 –240 Sec’s)
Table 120: Delay Alarm Reporting Time Locations
These locations programs the time in seconds that a delayed report waits dormant in the dial buffer before reporting to the receiving party. If a user code holder resets the alarm condition within this time frame, the control panel will clear the dialler buffer and prevent the alarm from reporting to the receiving party.
Electronics Design and Manufacturing Pty Limited ISSUE140
LOCATION 408 - 409
\"91%&"'(
408
409
Solution 844/862/880
Installation Manual
!7'0"<(O1%94(3&G7(
00
F709<&5%&"'(
Increments Of Days (Tens Digit)
Increments Of Days (Units Digit)
Table 121: Sensor Watch Time Locations
The time set in these two locations determine how many days (0-99) a zone may remain sealed before registering as a fault. This feature is only active when the system is in the disarmed state. If a zone programmed for sensor watch has not become unsealed and reset during this time, the
FAULT
indicator will illuminate. Refer to Fault Descriptions on page 74 for further information on sensor watch faults. Refer to Zone Options 1 on page 179 for programming zones for sensor watch.
The sensor watch time counter is only active whilst the control panel is disarmed. Therefore, if the system is only disarmed for 8 hours a day and the sensor watch time is programmed for 1 day, a zone that is programmed for sensor watch will register a sensor watch fault if not triggered during the disarmed state within 3 days.
This feature would be useful in a situation where someone has moved objects in the view of the detector, blocking out the detector from picking up movement.
LOCATION 410
?":751:(\"9B"$%(3&G7(
0
\"91%&"'(
410
F709<&5%&"'(
Increments Of 1 Minute (0 - 15 Minutes)
Table 122: Codepad Lockout Time Locations
All codepads will be locked out for the specified time programmed if an invalid code has been entered more times than allowed by the code retry attempts programmed in "LOCATION 356" on page 197. If the Codepad Lockout Time is programmed as zero, no codepad lockout will occur.
ISSUE140 Electronics Design and Manufacturing Pty Limited
System Event Timers 221
!&<7'(L$'(3&G7(
5
LOCATION 411
(Defaulted To 5 Minutes)
\"91%&"'(
411
F709<&5%&"'(
Increments Of 1 Minute (0 – 15)
Table 123: Siren Run Time Location
The siren run time determines how long the horn speaker will activate during an alarm condition. The siren run time can be programmed between 0 - 15 minutes (+/- 1 minute).
LOCATION 412
\"91%&"'(
412
!&<7'(!"$':(L1%7(
7
F709<&5%&"'(
Siren Sound Rate (0 = SLOWEST 15 = FASTEST)
Table 124: Siren Sound Rate Location
The siren sound rate varies the frequency of the siren tone. Programming the siren sound rate as a zero is the slowest and fifteen is the fastest. The siren sound rate does not change the frequency rate for the fire alarm tone.
Electronics Design and Manufacturing Pty Limited ISSUE140
LOCATION 413
Solution 844/862/880
Installation Manual
T$%"(T<G&'6(K<7YT#7<%(3&G7<(
1
\"91%&"'(
413
F709<&5%&"'(
Increments Of 5 Minutes (0 – 75 Minutes)
Table 125: Auto Arming Pre-Alert Timer Location
This location sets the time period that will warn you before the control panel will automatically arm in AWAY Mode. The codepad will beep once every second until the pre-alert timer has expired, after this time, the system will automatically arm itself in AWAY Mode. If you require the system to automatically arm in STAY Mode 1, enable Option 4 in “LOCATION
428” on page 233.
Once the control panel has automatically armed in AWAY Mode or STAY Mode 1, exit time will commence. If a valid user code is entered during the pre-alert time, the auto arming time as programmed in “LOCATION 414 - 417” will extend by one hour.
If you require a programmable output to operate during the auto arming pre-alert time, refer to
Output Event Type – Auto Arm Pre-Arming Alert Time on page 204.
LOCATION 414 - 417
T$%"(T<G&'6(3&G7(
0000
\"91%&"'(
414
415
416
417
F709<&5%&"'(
Actual Hour Of The Day (Tens Digit)
Actual Hour Of The Day (Units Digit)
Actual Minute Of The Day (Tens Digit)
Actual Minute Of The Day (Units Digit)
Table 126: Auto Arming Time Locations
These locations are used to program the actual time of the day that the system will automatically arm itself in AWAY Mode. This time must be set in 24 hour format (i.e.. 10:30
PM would be programmed as 2230). Refer to Option 4 in “LOCATION 428” on page 233 if you require the system to arm in STAY Mode 1.
If forced arming has been disabled for any zone, the feature of automatic arming will operate regardless of any zones being unsealed. Refer to Zone Options 2 on page 183 for more information on programming zones for forced arming.
User code 16 will be report when the feature of automatic arming is used.
On
Solution 880
control panels that have been partitioned into two separate areas, both areas will automatically arm in AWAY Mode at the same time every day.
ISSUE140 Electronics Design and Manufacturing Pty Limited
System Event Timers
LOCATION 418 - 421
LOCATION 422
223
T$%"(F&01<G&'6(3&G7(
0000
\"91%&"'(
418
419
420
421
F709<&5%&"'(
Actual Hour Of The Day (Tens Digit)
Actual Hour Of The Day (Units Digit)
Actual Minute Of The Day (Tens Digit)
Actual Minute Of The Day (Units Digit)
Table 127: Auto Disarming Time Locations
These locations are used to program the actual time of the day that the system will automatically disarm itself from AWAY Mode, STAY Mode 1 or STAY Mode 2. This time must be set in 24 hour format (i.e.. 10:30 PM would be programmed as 2230).
User code 16 will report when the feature of automatic disarming is used.
On
Solution 880
control panels that have been partitioned into two separate areas, both areas will automatically disarm at the same time every day.
programmed to automatically arm. To solve the problem, we suggest that you program the automatic arming time as 25:00 hours if you only require the control panel to disarm.
U&00Y>;;(O1&%(3&G7(
3
\"91%&"'(
422
F709<&5%&"'(
Increments Of 500 ms (500 ms – 8 Sec’s)
Table 128: Kiss-Off Wait Time Location
This location sets the time that the control panel will wait for acknowledgment before resending the report. This applies only to Contact ID Format and 4 + 2 Express Formats.
LOCATION 423
L707<M7:(
0
\"91%&"'(
423
F709<&5%&"'(
Reserved
Table 129: Reserved Location
Electronics Design and Manufacturing Pty Limited ISSUE140
Solution 844/862/880
Installation Manual
ISSUE140 Electronics Design and Manufacturing Pty Limited
System Event Timers 225
!=0%7G(3&G7(
0000
LOCATION 901 – 904
\"91%&"'(
901
902
903
904
F709<&5%&"'(
Current Hour In 24 Hour Time (Tens Digit)
Current Hour In 24 Hour Time (Units Digit)
Current Minute (Tens Digit)
Current Minute (Units Digit)
Table 130: System Time Locations
The
Solution 844/862/880
control panel has a real time 24 hour clock that needs to be set during installation. This time must be set in 24 hour format HHMM (i.e.. 10:30 PM would be programmed as 2230). Every time the system has been powered down, the system time will need to be reset.
Electronics Design and Manufacturing Pty Limited ISSUE140
LOCATION 905 – 910
\"91%&"'(
905
906
907
908
909
910
Solution 844/862/880
Installation Manual
!=0%7G(F1%7(
010101
F709<&5%&"'(
Day Of The Month (Tens Digit)
Day Of The Month (Units Digit)
Month Of The Year (Tens Digit)
Month Of The Year (Units Digit)
Year (Tens Digit)
Year (Units Digit)
Table 131: System Date Locations
The
Solution 844/862/880
control panel has a real time 12 month calendar that needs to be set during installation. This time must be set using the format DDMMYY (i.e.. If the date that is required to be set is the 1 July 1997, you would then program 010797). Every time the system has been powered down, the system date will need to be reset.
!7%%&'6(347(F1%7(1':(3&G7(
The Master Code holder is allowed to set the date and time as follows:
C"D(3"(!7%(347(E7D(F1%7(1':(3&G7(
1.
2.
3.
Enter your followed by
6
and the button.
Three beeps will be heard and the STAY and AWAY indicators will begin to flash.
Enter the day, month, year, hour and minute using the (DD, MM, YY, HH, MM) format
(i.e.. DD = Day of the month, MM = Month of the year, YY = Current year, HH = Hour of the day, MM = Minute of the day).
Please note that when programming the hour of the day, you will need to use 24:00 hour format.
Press the button when finished.
Two beeps will be heard and the STAY and AWAY indicators will extinguish. If a long beep is heard, an error was made when entering the date and time.
HI1G5#7(
If the date and time needs to be set for the 1st January 1997 at 10:30 PM, program the date and time as follows;
2580
+
6
+
0
+
1
+
0
+
1
+
9
+
7
+
2
+
2
+
3
+
0
+
ISSUE140 Electronics Design and Manufacturing Pty Limited
!=0%7G(1':(?"'0$G7<(>5%&"'0(
K<"6<1GG&'6(>5%&"'(V&%0(
When programming these locations, you will notice that there are four options per location.
You may select one, two, three or all four of these options, however, only one number needs to be programmed. This number is calculated by adding the option bit numbers together.
Program a seven (7) if you require options 1, 2 and 4 simultaneously (i.e.. 1 + 2 + 4 = 7).
HI1G5#7(
If at "LOCATION 424" you want options 1, 2 and 4, add the numbers together and the total is the number to be programmed. In this example, the number to be programmed is 7 (i.e.. 1 + 2
+ 4 = 7).
>5%&"'( F709<&5%&"'(
1
EDM Smart Lockout Allowed
2
Horn Speaker Monitor
Solution 844/862/880
Installation Manual
4
Strobe Indication For Radio Arm/Disarm
8
Horn Speaker Beeps For Radio Arm/Disarm
Table 132: Example - Programming Option Bits
ISSUE140 Electronics Design and Manufacturing Pty Limited
System and Consumer Options
LOCATION 424
N(
-(
*(
229
!=0%7G(>5%&"'0(N(
1
>5%&"'(
1
2
4
8
F709<&5%&"'(
EDM Smart Lockout Allowed
Horn Speaker Monitor
Strobe Indication For Radio Arm/Disarm
Horn Speaker Beeps For Radio Arm/Disarm
Table 133: System Options 1
HF2(!G1<%(\"9B"$%(T##"D7:(
This feature allows the control panel to remove any zones that are programmed for lockout dialler from the lockout list while the sirens are running. This feature allows a monitoring station to receive zone alarm reports from previously locked out zones during siren run time.
Refer to Zone Options 1 on page 179 for information on programming zones for lockout dialler and lockout siren.
Refer to Swinger Shutdown Count For Dialler on page 186 to program the number of times the zone can report before being locked out.
(C"<'(!571B7<(2"'&%"<(
If this option has been selected, the control panel will detect when the horn speaker has been disconnected from the speaker terminals. The
FAULT
indicator will illuminate when the horn speaker has been disconnected and will extinguish when the horn speaker has been reconnected.
If an output is required to operate when the horn speaker has been disconnected, refer to
Output Event Type – Horn Speaker Monitor Fail on page 206 for more information.
!%<"87(/':&91%&"'0(@"<(L1:&"(T<G+F&01<G(
This option will allow the strobe to indicate when the system is armed and disarmed when remotely operating the system via the Solution Wireless On/Off Interface (WE800).
E"(>;(!79"':0( !=0%7G(!%1%$0(
3 Seconds
System Disarmed
6 Seconds
6 Seconds
System Armed In AWAY Mode
System Armed In STAY Mode 1
Table 134: Strobe Indications For Remote Operations
)(
C"<'(!571B7<(V7750(@"<(L1:&"(T<G+F&01<G(
This option will allow the horn speaker to indicate when the system is armed and disarmed when remotely operating the system via the Solution Wireless On/Off Interface (WE800).
E"(>;(V7750( !=0%7G(!%1%$0(
1
2
System Disarmed
System Armed In AWAY Mode
3
System Armed In STAY Mode 1
Table 135: Horn Speaker Beeps For Remote Operations
Electronics Design and Manufacturing Pty Limited ISSUE140
LOCATION 425
N(
-(
*(
)(
>5%&"'(
1
2
4
8
Solution 844/862/880
Installation Manual
!=0%7G(>5%&"'0(-(
0
F709<&5%&"'(
Codepad Panic To Be Silent
Codepad Fire To Be Silent
Codepad Medical To Be Silent
Access Denied To Be Silent
Table 136: System Options 2
?":751:(K1'&9(3"(V7(!'%(
If this option has been selected, a codepad panic alarm or radio remote panic alarm will not operate the horn speaker, the bell or the strobe outputs. If this option is not selected, all three outputs will operate after a codepad panic alarm has been activated when the
1
and
3 buttons or the and buttons on the remote codepad are pressed simultaneously.
Selecting this option does not effect the operation of the communication dialler.
If you wish to disable the reporting of the codepad panic alarm, program “LOCATION 337 -
338” on page 192 as zero.
?":751:(@&<7(3"(V7(!'%(
If this option has been selected, a codepad fire alarm will not operate the horn speaker, the bell or the strobe outputs. If this option is not selected, all three outputs will operate after a codepad fire alarm has been activated when the
4
and
6
buttons on the remote codepad are pressed simultaneously. Selecting this option does not effect the operation of the communication dialler.
If you wish to disable the reporting of the codepad fire alarm, program “LOCATION 339 -
340” on page 193 as zero.
?":751:(27:&91#(3"(V7(!'%(
If this option has been selected, a codepad medical alarm will not operate the horn speaker, the bell or the strobe outputs. If this option is not selected, all three outputs will operate after a codepad fire alarm has been activated when the
7
and
9
buttons on the remote codepad are pressed simultaneously. Selecting this option does not effect the operation of the communication dialler.
If you wish to disable the reporting of the codepad medical alarm, program “LOCATION 341 -
342” on page 193 as zero.
T99700(F7'&7:(3"(V7(!'%(
If this option has been selected, a codepad tamper alarm will not operate the horn speaker, bell or the strobe outputs. If this option is not selected, all three outputs will operate after a codepad tamper alarm has occurred.
Refer to "LOCATION 356" on page 197 to set the number of invalid code retries before an alarm condition occurs. Selecting this option does not effect the operation of the communication dialler. If you wish to disable the reporting of access denied reports program
“LOCATION 357 - 358” as zero.
ISSUE140 Electronics Design and Manufacturing Pty Limited
System and Consumer Options
LOCATION 426
N(
-(
*(
231
!=0%7G(>5%&"'0(Q(
8
>5%&"'(
1
2
4
8
F709<&5%&"'(
AC Fail In 1 Hour (Disabled = After 2 Minutes)
Ignore AC Fail
Pulse Count Handover
Handover Delay To Be Sequential
Table 137: System Options 3
T?(@1&#(/'(N(C"$<(aF&018#7:(g(T;%7<(-(2&'$%70b(
If this option has been selected, the MAINS indicator will begin to flash as soon as the AC mains supply becomes disconnected. An "AC Loss" signal (Contact ID Event Code 301) will be transmitted to the base station receiver after the AC mains supply has been disconnected continuously for more than 60 minutes.
If this option has not been selected, the MAINS indicator will begin to flash and an "AC Loss" signal (Contact ID Event Code 301) will be transmitted to the base station receiver after the
AC mains power has been disconnected continuously for 2 minutes.
The MAINS indicator will cease to flash once the AC mains supply has been restored for more than two minutes. An “AC Loss Restore” report will be transmitted to the base station receiver after the AC mains supply has been restored continuously for more than 2 minutes irrespective of this option being set.
/6'"<7(T?(@1&#(
If this option has been selected, the
MAINS
indicator will not flash, nor will the codepad beep once every minute when the AC mains has been disconnected from the control panel. If you require a programmable output to operate when the AC mains has failed, refer to Output Event
Type – AC Fail on page 206.
If this options has been selected, an “AC Loss” report (Contact ID Event Code 301) will still report to the base station receiver unless disabled in “LOCATION 350 - 351” on page 195.
J"'7(K$#07(?"$'%(C1':"M7<(
If this option has been selected, any zone pulse count readings will handover and accumulate to any zone that is triggered during the same arming cycle. Zone pulse count handover will only operate with zone pulse count options 8-15. Refer to Zone Pulse Count on page 177 and Zone
Pulse Count Time on page 178 for more information.
24-hour zones do not receive any handover pulses from other zones. 24-hour zones can handover pulses to other zones.
)(
C1':"M7<(F7#1=(3"(V7(!7`$7'%&1#(
If this option has been selected, handover delay will be sequential (i.e.. In numerical order from lowest to highest). If the sequence is broken before the entry time expires, an alarm will occur.
If this option has not been selected, handover delay will follow the entry path provided that a delay zone has been triggered first. Refer to “Handover Zone” on page 175 for more information.
Electronics Design and Manufacturing Pty Limited ISSUE140
LOCATION 427
>5%&"'(
1
2
4
8
Solution 844/862/880
Installation Manual
!=0%7G(>5%&"'0(*(
0
F709<&5%&"'(
Panel To Power Up Disarmed (If Power Reset)
Arm/Disarm Tracking On Power Up
Internal Crystal To Keep Time
Keyswitch Interface, Night Arm Station Or RE005 Installed
Table 138: System Options 4
N(
-(
HI1G5#7(
(K1'7#(3"(K"D7<(Z5(F&01<G7:(a/;(K"D7<(L707%b(
If this option has been selected, the control panel will power up in the disarmed state once the battery and AC mains have been reconnected after the system has been powered down.
If this option is not selected, the system will always power up armed in AWAY Mode.
T<G+F&01<G(3<19B&'6(>'(K"D7<(Z5(
If enabled, the control panel will keep its current armed status in non-volatile memory. If for any reason the control panel is restarted due to a power failure, the control panel will return to the armed or disarmed status that the control panel was in before the power failed.
If the system was disarmed prior to the system being powered down, when the system is powered back up, the system will return to the disarmed state.
*(
)(
/'%7<'1#(?<=0%1#(3"(U775(3&G7(
If this option has been selected, it will force the control panel not to use the mains frequency as a time base to keep time. The control panel will use the internal crystal (XTAL) to keep track of time. This option is useful in countries that do not have a constant mains frequency.
U7=0D&%94(/'%7<;197f(E&64%(T<G(!%1%&"'(><(LH..R(/'0%1##7:(
This option must be selected when using the Radio Key/Keyswitch Interface (CC813), 2
Channel Radio Interface (RE005), or the Night Arm Station (CP105). This option allows the control panel to be operated using either of these three accessories. User Code 16 will be used when reporting open/close reports via any of these accessories.
Using a Solution 880 control panel that has been partitioned, the Night Arm Station will not operate the system.
ISSUE140 Electronics Design and Manufacturing Pty Limited
System and Consumer Options
LOCATION 428
N(
-(
*(
233
?"'0$G7<(>5%&"'0(N(
0
>5%&"'(
1
2
4
8
F709<&5%&"'(
Test Reports Only When Armed
Test Report After Siren Reset
Auto Arm In STAY Mode 1
STAY Indicator To Display Day Alarm Status
Table 139: Consumer Options 1
370%(L75"<%0(O47'(T<G7:(
If this option has been selected, test reports (Contact ID Event Code 602) will only be sent when the system has been armed in AWAY Mode, STAY Mode 1 or STAY Mode 2. It is no longer necessary to send a test report as well as an opening and closing report every day.
During the working week, most commercial premises would be open and therefore a test report is not necessary, as open and close reports would be sent at the time programmed. If you wish to manually send a test report, hold down the
9
button until two beeps are heard.
Refer to Test Reporting Time on page 199 to set the test report time required. To set the first test report, refer to the Installer Code Function – Set The Number Of Days Until The First Test
Report on page 87.
370%(L75"<%(T;%7<(!&<7'(L707%(
Selecting this option will force the control panel to send a test report after the siren has reset.
This can be used to indicate to the monitoring station that the control panel itself has not been tampered with during the alarm period.
T$%"(T<G(/'(!3T](2":7(N(
If automatic arming in STAY Mode 1 is preferred to automatic arming in AWAY Mode, this option will need to be selected.
Refer to “LOCATION 414 - 417” on page 222 to program the time that the control panel will automatically arm itself and “LOCATION 413” on page 222 to set the auto arming pre-alert time.
When using this option with a partitioned Solution 880 control panel, both areas will automatically arm in STAY Mode 1.
)(
(!3T](/':&91%"<(3"(F&05#1=(F1=(T#1<G(!%1%$0(
If this option has been selected, the
STAY
indicator will be used to display when day alarm has been enabled. The
STAY
indicator will flash once every 3 seconds while day alarm is active.
Refer to “LOCATION 265” on page 168 for programming zones to operate for day alarm operation.
Day alarm can be turned on and off by holding down the
4
button for 2 seconds. Three beeps indicate day alarm is turned on and two beeps indicate day alarm is turned off. Refer to Day
Alarm Operation on page 169 for more information.
Electronics Design and Manufacturing Pty Limited ISSUE140
LOCATION 429
N(
-(
*(
)(
>5%&"'(
1
2
4
8
Solution 844/862/880
Installation Manual
?"'0$G7<(>5%&"'0(-(
2
F709<&5%&"'(
Codepad Display Extinguish After 60 Seconds
Single Button Arming Allowed (AWAY/STAY Mode 1 & 2)
Single Button Disarming Allowed (STAY Mode 1 & 2)
Alarm Memory Reset On Disarm
Table 140: Consumer Options 2
?":751:(F&05#1=(HI%&'6$&04(T;%7<(,.(!79"':0((
If this option has been selected, all indicators on the remote codepad display will extinguish if a button is not pressed for 60 seconds. The indicators will illuminate when there is an alarm
(except a silent alarm), when a button is pressed on the codepad, when the AC mains fail beeps, or if the entry timer has been activated.
!&'6#7(V$%%"'(T<G&'6(T##"D7:(aTOT]+!3T](2":7(N(h(-b(
If this option has been selected, the hold down functions for arming in AWAY Mode, STAY
Mode 1 and STAY Mode 2 will be functional. Refer to Hold Down Functions on page 118 for more information.
!&'6#7(V$%%"'(F&01<G&'6(T##"D7:(a!3T](2":7(N(h(-b(
This option will only operate when Option 2 in this location has also been selected. This option will allow hold down functions for disarming from STAY Mode 1 and STAY Mode 2.
Refer to Hold Down Functions on page 118 for more information.
T#1<G(27G"<=(L707%(>'(F&01<G((
This option allows the memory of alarm events to be cleared from the remote codepad when the system has been disarmed. If this option has not been selected, the system will need to be armed and disarmed again to clear alarm memory from the remote codepad.
ISSUE140 Electronics Design and Manufacturing Pty Limited
System and Consumer Options
LOCATION 430
N(
-(
*(
235
?"'0$G7<(>5%&"'0(Q(
5
>5%&"'(
1
2
4
8
F709<&5%&"'(
Codepad Fault Alarm Beeps Allowed
Use Digit 3 For Codepad Duress Instead Of Digit 9
Alarms Activate Sirens & Strobe In STAY Mode 1 & 2
Reserved
Table 141: Consumer Options 3
?":751:(@1$#%(T#1<G(V7750(T##"D7:(
If this option has been enabled, the codepad will flash the FAULT indicator and beep once every minute until acknowledged when a system fault has occurred. To acknowledge a new fault and stop the codepad from beeping once every minute, simply press the button.
If this option has not been enabled, the codepad will only flash the
FAULT
indicator when a new fault has occurred, but will not cause the codepad to beep once every minute until the fault has been acknowledge or rectified.
Z07(F&6&%(Q(@"<(?":751:(F$<700(/'0%71:(>;(F&6&%(X(
This option if selected, will allow the customer to use the digit
3
after entering their code to disarm the system to activate a duress alarm.
T#1<G(T9%&M1%70(!&<7'0(h(!%<"87(/'(!3T](2":7(N(h(-(
This option will need to be selected if audible alarms are required when the system has been armed in STAY Mode 1 or STAY Mode 2.
L707<M7:(
)(
Electronics Design and Manufacturing Pty Limited ISSUE140
LOCATION 431
N(
-(
Q(
>5%&"'(
1
2
3
4
Solution 844/862/880
Installation Manual
L1:&"(/'5$%(>5%&"'0(
0
F709<&5%&"'(
Radio Receiver (WE800)
Latching Keyswitch Input
Momentary Keyswitch Input
Reserved
Table 142: Radio Input Options
L1:&"(L797&M7<(aOH)..b(
This option needs to be selected when using the optional 304 Mhz RF Receiver (WE800) for remote operations using radio remote hand held transmitters.
\1%94&'6(U7=0D&%94(/'5$%(
This option allows you to connect a latching keyswitch to the JP3 terminals D and GND to remotely arm and disarm the system in AWAY Mode.
2"G7'%1<=(U7=0D&%94(/'5$%(
This option allows you to connect a momentary keyswitch to the JP3 terminals D and GND to remotely arm and disarm the system in AWAY Mode.
ISSUE140 Electronics Design and Manufacturing Pty Limited
K1<%&%&"'&'6(
Solution 844/862/880
Installation Manual
The
Solution 880
control panel includes a feature called partitioning which can effectively transform your single control panel and split the system into two separate controllable areas.
Normally arming and disarming the system would turn the entire system on or off. However, when the
Solution 880
control panel has been partitioned, you may arm or disarm an individual area without affecting the other area.
Partitioning is extremely useful when you wish to secure sheds, dual occupancy dwellings, granny flats, shops and offices.
When partitioning, only the CP5 Area Addressable (CP500A) codepad and the CP5 Master
Partitioned (CP500P) codepad can be used.
?KR(210%7<(K1<%&%&"'7:(\HF(?":751:(
Figure 13: CP5 Master Partitioned LED
Codepad (CP500P)
This codepad is only used on the
Solution 880
control panel when partitioned. The Master Partitioned LED codepad will allow the user to operate both areas individually from the same codepad, without the need to operate individual areas from separate codepads.
The codepad is the communications interface between you and your alarm system. The codepad allows you to issue commands and offers both visual and audible indications that guide you through the general operation.
The codepad incorporates numerous indicators. There are
ZONE
indicators that are used to show the condition of each zone and four others for general status. The following is a list of situations and the relevant indications that will be seen.
The indicators on a CP5 Master Partitioned LED codepad are configured in to four groups.
Following is a description of what the indicators mean.
N(
J"'7(/':&91%"<0(
The
ZONE
indicators are used to display the status of the zones. The following table lists the various circumstances that the indicators will display (i.e.. Zone Sealed, Zone Unsealed).
/':&91%"<( F7;&'&%&"'(
On
Zone Is Unsealed
Off
Flashing Fast
(0.25 Sec On – 0.25 Sec Off)
Flashing Slow
(1 Sec On – 1 Sec Off)
Zone Is Sealed
Zone Is In Alarm Condition
Zone Is Manually Isolated
Table 143: Zone Indicators
ISSUE140 Electronics Design and Manufacturing Pty Limited
Partitioning
-(
Q(
*(
239
T<71(>'+>;;(/':&91%"<0(
The group of four Area On/Off indicators (1 – 4) show the status of each area (i.e.. If an indicator is illuminated, that area is armed and if the indicator is not illuminated, that area is disarmed).
If an area is armed in STAY Mode 1, the corresponding Area On/Off indicator will be illuminated in conjunction with the PARTIAL indicator. If the area is armed in AWAY Mode, only the corresponding Area On/Off Indicator will be illuminated.
T<71(>'+>;;(/':&91%"<( F7;&'&%&"'(
On
Area Is Armed In AWAY Mode Or STAY Mode 1
Off
Area Is Disarmed
Table 144: Area On/Off Indicators
T<71(F&05#1=(/':&91%"<0(
A group of four Area Display Indicators indicate which area is currently being displayed (i.e..
If number 1 is being displayed, all information provided on the display relates only to Area 1.
If number 2 is being displayed, all information provided on the display relates only to Area 2).
Pressing the button will toggle or move you to the next area display (i.e.. If Area 1 is currently being displayed, pressing the button will toggle or move you to Area 2.
Pressing the
1).
button a second time will toggle you back to display information for Area
T<71(F&05#1=(/':&91%"<0( F7;&'&%&"'(
On
Indicates Current Area Being Displayed
Off
Indicates Current Area Not Being Displayed
Table 145: Area Display Indicators
!%1%$0(/':&91%"<0(
A group of four indicators display the following:
KTL3/T\(/':&91%"<(
The
PARTIAL
indicator is used to display that the system is armed in
STAY
Mode 1. The
PARTIAL indicator will also flash in unison with the AUX indicator when Installer’s
Programming Mode or Master Code Functions are used.
For the different methods of arming the system in STAY Mode 1, refer to page 64. Refer to
Zone Options 1 on page 173 for information on setting zones to be automatically isolated in
STAY Mode 1.
/':&91%"<( F7;&'&%&"'(
On
System Is Armed In STAY Mode 1
Off
System Is Not Armed In STAY Mode 1
Table 146: Partial Indicator
Electronics Design and Manufacturing Pty Limited ISSUE140
ISSUE140
Solution 844/862/880
Installation Manual
TZ^(/':&91%"<(
If Option 8 in “LOCATION 432” on page 243 has been enabled, the
AUX
indicator will be used to display when the control panel is using the telephone line. The
AUX
indicator will also flash in unison with the PARTIAL indicator when Installer’s Programming Mode or Master
Code Functions are used.
/':&91%"<(
On
Off
Flashing
F7;&'&%&"'(
System Is Armed In STAY Mode 1 Or STAY Mode 2
System Is Not Armed In STAY Mode
Zone Isolating Mode Or Setting STAY Mode 2 Zones
Table 147: AUX Indicator
2T/E!(/':&91%"<(
The MAINS indicator is used to display that the systems AC mains supply is normal or has failed.
When programming numbers (i.e. Installer’s Programming Mode or Master Code Functions), the MAINS indicator will illuminate when you program numbers between 10 and 15. The
MAINS indicator represents digit 10 plus the value of the illuminated zone indicator (e.g.: If you program a twelve, the
MAINS
indicator and zone 2 will illuminate).
/':&91%"<(
On
Flashing
F7;&'&%&"'(
AC Mains Power Normal
AC Mains Failure
Table 148: MAINS Indicator
@TZ\3(/':&91%"<(
The FAULT indicator is used to display that the system has detected a system fault. Refer to
Fault Analysis Mode on page 73 for more information on system faults.
Every time a new system fault has been detected (e.g.: FAULT indicator flashing), the codepad will begin to beep once every minute.
Pressing the button once will cancel the once a minute beep and acknowledge the fault
(e.g.:
FAULT
indicator on).
/':&91%"<(
On
Off
Flashing
F7;&'&%&"'(
There Is A System Fault That Needs To Be Rectified
The System Is Normal, There Are No Faults
There Is A System Fault Waiting To Be Acknowledged
Table 149: FAULT Indicator
Electronics Design and Manufacturing Pty Limited
Partitioning 241
T$:&8#7(/':&91%"<0(
In general, the audible indications given out by the codepad are as follows:
/':&91%"<( F7;&'&%&"'(
One Short Beep
A Button Has Been Pressed On The Codepad Or End
Of Exit Time When Armed In Either STAY Mode 1 Or
STAY Mode 2
Two Short Beeps
The System Has Accepted Your Code
Three Short Beeps
One Long Beep
The Requested Function Has Been Executed
Indicates The End Of Exit Time In AWAY Mode Or
The Requested Operation Has Been Denied Or Aborted
Walk Test Mode Is Currently Active Or Warning
Before Automatic Arming Takes Place
One Short Beep Every Second
One Short Beep Every Two
Seconds
Telephone Monitor Mode Is Active
One Short Beep Every Minute
There Is A System Fault Waiting To Be Acknowledged
Table 150: Audible Indications
Electronics Design and Manufacturing Pty Limited ISSUE140
Solution 844/862/880
Installation Manual
>57<1%&'6(?":751:0(/'(K1<%&%&"'&'6(
>57<1%&'6(@<"G(T(?KR(T<71(T::<70018#7(\HF(?":751:(
When operating a CP5 Area Addressable (CP500A) codepad in a system that has been partitioned, the display and operations are exactly the same as the CP5 Eight Zone LED codepad except that the commands issued from the codepad only effects the area that the codepad is allocated to. Refer to System Operations on page 62 for more information on operating the system.
HI1G5#7(
If the codepad is allocated to Area 2, only user codes that have been allocated to Area 2 can operate the codepad. If user codes only have access to Area 1, entering their code at the Area 2 codepad will not operate Area 1 or Area 2.
If you wish to determine which codepad you are currently operating, hold down the
8
button to determine which area that the codepad is allocated to (i.e.. If Zone 1 illuminates, the codepad is allocated to Area 1, if Zone 2 illuminates, the codepad is allocated to Area 2). Refer to Hold
Down Functions on page 118 for more information.
>57<1%&'6(@<"G(T(?KR(210%7<(K1<%&%&"'7:(?":751:(
When operating a CP5 Master Partitioned (CP500P) codepad in a system that has been partitioned, all operations are the same as the CP5 Area Addressable codepad with one exception. All operations are only related to the Area Display that is being indicated on the codepad at the time (i.e.. If the Area Display illuminates number 2, the codepad is displaying information only for Area 2. Therefore, all operations will only effect Area 2).
Refer to System Operations on page 62 for more information on operating the system.
C"D(3"(2"M7(@<"G(>'7(T<71(3"(347(E7I%(
1.
Press the button.
The Area Display indicator will move to the next area display (i.e.. If the Area Display illuminates number 1, pressing the button will toggle to display Area 2. Pressing the button a second time will toggle the display back to Area 1).
ISSUE140 Electronics Design and Manufacturing Pty Limited
Partitioning
K<"6<1GG&'6(
LOCATION 432
N(
-(
243
The following locations area only applicable when partitioning the
Solution 880
control panel. Remember that when programming option bit locations, you may add the options together (e.g.: If you require both options 2 and 4, you would add the two options together and program a 6).
K1<%&%&"'&'6(>5%&"'0(N(
0
>5%&"'(
1
2
4
8
F709<&5%&"'(
First To Open/Last To Close Reporting
Area 1 Codepad Connected To Data Terminal
Reset Sirens From Any Area Allowed
Master Codepad To Display AUX Indicator When On-Line
Table 151: Partitioning Options 1
@&<0%(3"(>57'+\10%(3"(?#"07(L75"<%&'6(
This option needs to be enabled if only one Open/Close report is required when the system has been partitioned. Rather than having individual Open/Close reports fore each area, a closing report will be transmitted only when BOTH areas have been armed and an opening report will be transmitted as soon as one area has been disarmed.
The reports will be transmitted on the Subscriber ID Number allocated to that particular area.
Subscriber ID Numbers and Open/Close reports must be programmed for both areas.
The option of first to open/last to close reporting is only applicable when all user codes have their priority level set with no open/close reports. Therefore, if user codes have priority levels set to open/close reports, an opening or closing report will always be reported when any area is disarmed or armed irrespective of which area was first to open or last to close.
T<71(N(?":751:(?"''79%7:(3"(F1%1(37<G&'1#(
If this option has been enabled, the DATA terminal on the
Solution 880
control panel will be configured to transmit status information only relevant to Area 1. This allows you to connect an area addressable codepad (CP500A) set for Area 1 operation to the DATA terminal of the control panel instead of connecting the addressable codepad to an output.
If this option has not been enabled, the CP5 Master Partitioned (CP500P) codepad will need to be used as the DATA terminal on the control panel would display information for both Area 1 and Area 2.
An advantage in using this option is that it allows you to configure a system into separate areas while still leaving the maximum number of programmable outputs available for other applications.
Electronics Design and Manufacturing Pty Limited ISSUE140
*(
)(
LOCATION 433
N(
-(
*(
Solution 844/862/880
Installation Manual
L707%(!&<7'0(@<"G(T'=(T<71(T##"D7:(
This option is only applicable when the control panel has been partitioned. If this option has been enabled, any valid user code from either Area 1 or Area 2 will be able to reset the horn speaker, strobe, bell or EDMSAT outputs from operating. This option does not allow a user code allocated from one area to disarm another area.
210%7<(?":751:(3"(F&05#1=(TZ^(/':&91%"<(O47'(>'Y\&'7(
If this option has been enabled, the AUX indicator on the CP5 Master Partitioned (CP500P) codepad will illuminate when the control panel has seized the telephone line to transmit a report. The
AUX
indicator will extinguish once the telephone line has been released.
>5%&"'(
1
2
4
8
K1<%&%&"'&'6(>5%&"'0(-(
0
F709<&5%&"'(
Lock Area 1 To Receiver 1 and Lock Area 2 To Receiver 2
User Codes Can Arm/Disarm Both Areas At Same Time (Code + 0 + #)
Reserved
Reserved
Table 152: Partitioning Options 2
\"9B(T<71(N(3"(L797&M7<(N(1':(\"9B(T<71(-(3"(L797&M7<(-(
If this option has been selected, it will automatically set all reports for Area 1 to Receiver 1 and all reports on Area 2 to Receiver 2.
If this option has not been selected, all reporting will need to be manually programmed to report on Receiver 1 or Receiver 2 for both areas.
Z07<(?":70(?1'(T<G+F&01<G(V"%4(T<710(T%(!1G7(3&G7(a?":7(e(.(e(kb(
If this option ahs been selected, it will allow any user allocated to both areas to arm or disarm both areas at the same time without the need to enter the code at each area codepad. Refer to
Arm or Disarm Both Areas At The Same Time on page 99 and 117 for more information.
If the user arms both areas at the same time, if in “LOCATION 432” on page 243 has the option “First To Open/Last To Close Reporting” enabled, only a closing report for the Area 2 will be reported.
If the user disarms both areas at the same time, if in “LOCATION 432” on page 243 has the option “First To Open/Last To Close Reporting” enabled, only an opening report for Area 1 will be reported.
L707<M7:(
L707<M7:(
)(
ISSUE140 Electronics Design and Manufacturing Pty Limited
Partitioning
J"'7(T##"91%&"'0(
245
Each area can have up to eight zones allocated to it. The eight locations for each area represents ZONE indicators one to eight on the remote area addressable codepad. Any of the zone inputs 1 – 8 can be mapped to any area to appear as any zone on the remote area addressable codepad (i.e.. Any zone can be programmed to both Area 1 and Area 2 to become common zones).
Zones that have been programmed as common zones (e.g.: Allocated to both Area 1 and Area
2) will report to the base station receiver on group zero (i.e. Area 1 = Group 1 and Area 2 =
Group 2). Zones that are allocated only to one area will report on the corresponding group number. Common zones that are programmed other than 24 hour zone types will not activate an alarm until both areas have been armed in either AWAY Mode or STAY Mode 1.
LOCATION 434 - 441
J"'7(T##"91%&"'0(@"<(T<71(N(
00000000
\"91%&"'(
434
435
436
437
438
439
440
441
Area 1 – Zone 1 Indicator
Area 1 – Zone 2 Indicator
Area 1 – Zone 3 Indicator
Area 1 – Zone 4 Indicator
Area 1 – Zone 5 Indicator
Area 1 – Zone 6 Indicator
Area 1 – Zone 7 Indicator
Area 1 – Zone 8 Indicator
F709<&5%&"'(
Table 153: Solution 880 – Zone Allocations For Area 1
LOCATION 442 - 449
J"'7(T##"91%&"'0(@"<(T<71(-(
00000000
\"91%&"'(
442
443
444
445
446
447
448
449
Area 2 – Zone 1 Indicator
Area 2 – Zone 2 Indicator
Area 2 – Zone 3 Indicator
Area 2 – Zone 4 Indicator
Area 2 – Zone 5 Indicator
Area 2 – Zone 6 Indicator
Area 2 – Zone 7 Indicator
Area 2 – Zone 8 Indicator
F709<&5%&"'(
Table 154: Solution 880 – Zone Allocations For Area 2
Electronics Design and Manufacturing Pty Limited ISSUE140
Solution 844/862/880
Installation Manual
HI1G5#7(
In this example, zones 1, 2, 3 and 4 have been allocated to Area 1 to appear as zones 1, 2, 3 and
4. Zones 1, 5, 6, 7 & 8 have been allocated to Area 2 to appear as zones 1, 5, 6, 7 and 8.
Programming the same zone into more than one area indicates that the zone will operate as a common zone.
Figure 14: Area 1 Codepad Display
Area 1 Zone Allocations
LOCATION 434 – 441
12340000
Figure 15: Area 2 Codepad Display
Area 2 Zone Allocations
LOCATION 442 – 449
10005678
ISSUE140 Electronics Design and Manufacturing Pty Limited
Partitioning 247
Z07<(?":7(T##"91%&"'0(
“LOCATION 450 – 465” are used to assign each user code to an area or multiple areas when the
Solution 880
control panel has been partitioned. A number 0 – 3 is required to be entered into each of these locations to assign each user code holder to the areas they are required to operate. Multiple user codes can be allocated to the same areas.
Select the required areas that the user code holder is to operate and then add the options values together from “Table 155: User Code Allocations” below (e.g.: If the user code is allocated to operate both Area 1 and Area 2, program a 3 (i.e.. 1 + 2 = 3) into the required location relevant to their user code allocation. If the user code is allocated only to Area 1, program their user code allocation as 1).
>5%&"'( T##"91%7:(T<710(
0
Not Allocated To An Area
1
2
3
Allocated To Area 1
Allocated To Area 2
Allocated To Area 1 + Area 2
Table 155: User Code Allocations
Location Location Location 453
Z07<(?":7(N( .( ( Z07<(?":7(-( .( ( Z07<(?":7(Q( .( ( Z07<(?":7(*( .(
Location Location Location 457
Z07<(?":7(R( .( ( Z07<(?":7(,( .( ( Z07<(?":7(S( .( ( Z07<(?":7()( .(
Location Location Location 461
Z07<(?":7(X( .( ( Z07<(?":7(N.( .( ( Z07<(?":7(NN( .( ( Z07<(?":7(N-( .(
Location Location Location 465
Z07<(?":7(NQ( .( ( Z07<(?":7(N*( .( ( Z07<(?":7(NR( .( ( Z07<(?":7(N,( .(
Electronics Design and Manufacturing Pty Limited ISSUE140
Solution 844/862/880
Installation Manual
!7%%&'6(Z5(1':(K<"6<1GG&'6(?":751:0(@"<(K1<%&%&"'&'6(
Only the CP5 Area Addressable (CP500A) and CP5 Master Partitioned (CP500P) codepads can be used when partitioning a
Solution 880
control panel.
!7%%&'6(Z5(347(210%7<(K1<%&%&"'7:(?":751:(T0(347(21&'(?":751:j(
If you are using the CP5 Master Partitioned (CP500P) codepad as the main codepad when partitioning, you need to connect the codepad to the main codepad terminals (CP-, CP+, CLK and DATA). All DIP switches on the back of the codepad will need to be set to the ON position.
!7%%&'6(Z5(T'(T<71(N(?":751:(T0(347(21&'(?":751:(
If you are not using the CP5 Master Partitioned codepad as the main codepad of the partitioned system, you need to connect the Area 1 codepad to the main codepad terminals (CP-, CP+,
CLK and DATA). In addition to setting up the Area 1 Codepad, you will need to set DIP switch 1 on the back of the codepad into the ON position and enable Option 2 in “LOCATION
432” on page 243.
!7%%&'6(Z5(T'(T<71(N(?":751:(
If you wish to have a separate area codepad only for Area 1 when using the CP5 Master
Partitioned codepad as the main codepad, you will need to connect the Area 1 codepad to the main codepad terminals (CP-, CP+ and CLK) with the DATA terminal to be connected to one of the programmable outputs programmed as “6,0 – Area 1 Codepad Data”. DIP switch 1 on the back of the Area 1 codepad will need to be in the ON position.
!7%%&'6(Z5(T'(T<71(-(?":751:(
If you wish to have a separate area codepad only for Area 2 when using either the CP5 Master
Partitioned codepad or another area codepad for Area 1, you will need to connect the Area 2
Codepad to the main codepad terminals (CP-, CP+ and CLK) with the DATA terminal to be connected to one of the programmable outputs programmed as “6,1 – Area 2 Codepad Data”.
DIP switch 2 on the back of the Area 2 codepad will need to be in the ON position.
ISSUE140
Figure 16: DIP Switch Location On Back Of Codepad PCB
Electronics Design and Manufacturing Pty Limited
Partitioning 249
?":751:(?"''79%&"'0(@"<(K1<%&%&"'&'6(
If the CP-5 Area Addressable (CP500A) codepad is assigned to
Area 1, DIP Switch 1 on the back of the remote codepad will need to be in the ON position. The following locations for Output 1 will need to be programmed.
[LOCATION 368 = 6, 369 = 0]
If the CP-5 Area Addressable (CP500A) codepad is assigned to
Area 2, DIP Switch 2 on the back of the remote codepad will need to be in the ON position. The following locations for Output 1 will need to be programmed.
[LOCATION 368 = 6, 369 = 1]
Figure 17: Connections For CP-5 Master Partitioned (CP500P) Codepad
and CP-5 Area Addressable (CP500A) Codepad
The following DIP Switch settings and locations must be programmed for the two CP-5 Area Addressable (CP500A) codepads to function correctly.
AREA 1 CODEPAD
DIP Switch 1 on the back of the remote codepad will need to be in the ON position. The following location will also need to be programmed.
[LOCATION 432, Option bit 2 must be enabled]
AREA 2 CODEPAD - (Output 1)
DIP Switch 2 on the back of the remote codepad will need to be in the ON position. The following locations for Output 1 will need to be programmed.
[LOCATION 368 = 6, 369 = 1]
Figure 18: Connections For Two CP-5 Eight Zone Area
Addressable (CP500A) Codepads
Electronics Design and Manufacturing Pty Limited ISSUE140
Solution 844/862/880
Installation Manual
ISSUE140 Electronics Design and Manufacturing Pty Limited
>5%&"'1#(H`$&5G7'%(
Solution 844/862/880
Installation Manual
>5%&"'1#(H`$&5G7'%(
EDM manufactures numerous accessories that can be used in conjunction with the
Solution
844/862/880
control panel. These optional pieces of equipment will enhance certain features thus making the system extremely flexible.
-(?41''7#+*(?41''7#(C1':(C7#:(3<1'0G&%%7<0(Q.*(24d(aLH.N-+LH.NQb(
These hand held radio transmitters can be used in conjunction with the 304 Mhz RF Receiver
(WE800) to remotely operate the system. Both hand held transmitters have the ability to remotely arm and disarm the system in AWAY Mode or STAY Mode 1 and activate remote panic alarms. The 4 channel hand held transmitter has the added ability to operate outputs such as garage doors, swimming pool pumps or outside lights etc.
Q.*(24d(L@(L797&M7<(aOH)..b(
This interface was designed to allow the use of up to eight radio user codes (9 – 16). This is useful if you require the system to be radio controlled and you would like to give your customer total control via a radio hand held remote transmitter.
ISSUE140
Figure 19: Solution Wireless ON/OFF Interface (WE800)
-(?41''7#(L1:&"(/'%7<;197(aLH..Rb(
The EDM 2 channel radio interface has been designed to allow customers to remotely operate
Solution control panels and control two on-board relays. The interface may also be used as a stand alone receiver, independent of a Solution control panel and used solely for remote control of external devices connected to the two on-board relays.
The interface’s operating frequency is 304 Mhz with the ability to store up to 120 radio remote codes. When connecting the interface to a Solution control panel, there is only a three wire connection in parallel to the codepad and Option 8 in “LOCATION 427” on page 232 needs to be programmed.
Electronics Design and Manufacturing Pty Limited
Optional Equipment 253
HF2!T3(Y(!1%7##&%7(!&<7'(a!!XN*b(
The EDMSAT Satellite Siren is a totally self contained unit incorporating a high powered siren and a weatherproof strobe. A 1.2 AH sealed lead acid battery needs to be fitted. The
EDMSAT requires only two wires for operation on which the charging of the battery and triggering of the siren and strobe are carried out. This is done by pulse code modulating
(PCM) the charging voltage. Any attempt to tamper with the wiring or to substitute an alternative power source across the wiring will disrupt the data transmission and the EDMSAT will activate immediately. When the EDMSAT carries out a battery test, the unit will sound for two seconds if the battery test fails. Refer to the Output Event Type – EDMSAT - Satellite
Siren on page 204 when programming a programmable output for the satellite siren.
C1':(C7#:(K<"6<1GG7<(a??)N*b(
The hand held programmer is used to program the locations in the
Solution
844/862/880
control panel. The unit displays the actual location number and the data value currently programmed. It comes complete with a one metre connecting cable and a socket for an external programming key. Refer to Programming With The Hand Held
Programmer on page 31 for more information.
K<"6<1GG&'6(U7=(a??)XNb(
The programming key is a unique device that will store all programming information programmed in your control panel once copied to the programming key. The programming key can hold all your common configuration data such as monitoring station telephone numbers and zone reporting channels etc.
T#1<G(\&'B(!";%D1<7(a??)N,b(
This software package is designed to be used for programming the
Solution
844/862/880
control panel by either the direct connect method or the remote connect method via the telephone line. All options and features can be accessed using this software as well as maintaining history and service reports. Refer to "LOCATION 180" on page 129 or
160 to enable this feature. Refer to Alarm Link Software on page 126 for more information on the remote connect methods.
?KR(H&64%(J"'7(\HF(?":751:(a?KR.)b(
This codepad is designed to operate with the
Solution
range of control panels. This codepad provides indications for up to 8 zones. This codepad cannot be used with the
Solution 880
control panel when partitioned.
?KR(H&64%(J"'7(\?F(?":751:(a?KR.)\b(
This codepad is designed to operate with the
Solution
range of control panels with a fixed icon display. This codepad provides indications for up to 8 zones. This codepad cannot be used with the
Solution 880
control panel when partitioned.
?KR(H&64%(J"'7(T<71(T::<70018#7(?":751:(a?KR..Tb(
This codepad is designed to operate with the
Solution 880
control panels when partitioned.
These codepads have DIP switches on the back of the codepad to select which area in partitioning that the codepad belongs to. Refer to Setting Up and Programming Codepads For
Partitioning on page 248 and Codepad Connections For Partitioning on page 249 for more information.
?KR(210%7<(K1<%&%&"'7:(?":751:(a?KR..Kb(
This codepad is designed to operate with the
Solution 880
control panels when partitioned.
These codepads allow the entire system to be operated from the single codepad allowing the user to toggle between separate areas by pressing the button. This means that there is no need to have separate CP5 Area Addressable (CP500A) codepads for each area. Refer to
Setting Up and Programming Codepads For Partitioning on page 248 and Codepad
Connections For Partitioning on page 249 for more information.
Electronics Design and Manufacturing Pty Limited ISSUE140
Solution 844/862/880
Installation Manual
E&64%(T<G(!%1%&"'(a?KN.Rb(
The night arm station incorporates a panic button and is designed to allow system operation from a bedroom or sitting room to arm and disarm the system in STAY Mode 1. Refer to
Option 8 in “LOCATION 427” on page 232 to enable the night arm station to operate with the system.
K4"'7(?"'%<"##7<(a??XNNb(
The phone controller operates at a frequency of 1400 Hz and allows the user to remotely arm the system in AWAY Mode via the telephone. This phone controller can also be used to acknowledge a phone call from the control panel when the system is set up for domestic dialling.
C1':(C7#:(F&1##7<(370%7<(aFFX.Nb(
The hand held dialler tester simulates a base station for testing of the control panel's dialling functions. It communicates in most formats.
?7##$#1<(F&1##7<0(
The cellular dialler when connected to the control panel will transmit alarm information via the cellular phone network to the base station receiver when a land telephone line is not present or has been tampered with.
K!N..(K"D7<(!$55#=(2":$#7(aK!N..
b
The PS100 Power Supply Module has been designed for applications requiring 13.8 volts DC at currents of up to 1 Amp and must be used in conjunction with the TF008 - 18 volt AC plug pack.
The unit comes complete with our standard, fully short circuit proof, power out and battery charging terminals as well as a DC LED indicator and AC mains fail output. For situations requiring an uninterrupted power source, a rechargeable sealed lead-acid battery can be connected. In the event of an AC mains failure, the power supply will switch to battery power without interrupting the load being supplied.
3@..)(K#$6(K19B(a3@..)b(
The TF008 plug packs have been designed to be used with the EDM control panels and the
PS100 Power Supply Module. The plug pack includes built in thermal fuses that under overload or fault conditions will blow and eliminate any possible fire threat due to excessive heat build up inside the casing.
The TF008 plug pack incorporates a three wire flying lead that enables a mains earth connection to be made between the equipment and the plug pack. This connection may be required for lightning protection on equipment that is connected to phone lines or for safety reasons such as earthing of metal enclosures.
!"#$%&"'(?":751:(2&G&9(V"1<:(a??)-.b(
The Solution Codepad Mimic Board (CC820) has been designed to allow you to have a separate output indicator for each indicator found on the remote codepad. This will be useful to remotely display system status information.
ISSUE140 Electronics Design and Manufacturing Pty Limited
Optional Equipment 255
-(O&<7(!G"B7(F7%79%"<(/'%7<;197([email protected](
The 2 Wire Smoke Detector Interface (FA101) has been designed to allow high quality 2 wire,
24 volt DC smoke detectors to be easily connected to the Solution range of control panels. The interface provides the 24 volts required to power the smoke detector and also provides a relay output that is used to trigger the control panel. Multiple detectors may be connected to the same interface.
L1:&"(U7=+U7=0D&%94(/'%7<;197(a??)NQb(
This interface was designed to allow simple interfacing of a momentary keyswitch or radio equipment for remote control operations to operate the control panel.
If the R/K terminal is used, a number of momentary keyswitches may be connected in parallel for multiple arm/disarm locations. The ON and OFF terminals can be used to directly interface to any access control system.
The HOME terminal will force the system to arm and disarm in STAY Mode 1.
There is also a PANIC terminal that allows the customer to issue a panic alarm from a remote keyswitch or hand held radio transmitter.
This is handy if you require your system to be radio controlled and you would like to give your customer total control via a hand held radio remote.
Electronics Design and Manufacturing Pty Limited ISSUE140
Solution 844/862/880
Installation Manual
ISSUE140 Electronics Design and Manufacturing Pty Limited
37<G&'1#0(1':(F709<&5%&"'0(
Solution 844/862/880
Installation Manual
37<G&'1#(F7;&'&%&"'0(1':(F709<&5%&"'0(
37<G&'1#(
HTL3C(
(
N)P(T?(
( eVT33HL](
YVT33HL](
(
_EF( eN-P(
?\U(
FT3T(
(
(
!3L(
>Z3(N( e?>2(
(
(
(
?>22(
E+>(
( eN-P(
J*(
JQ(
( eN-P(
_EF(
(
J-(
JN( eN-P(
F709<&5%&"'(
This terminal should be connected to the green wire on the TF008 Plug Pack that is internally connected to the mains earth. Extensive lightning protection has been built into the control panel and this terminal will have to be connected correctly if you are to take the best advantage of the protection provided.
These two terminals are plug on type, and are the termination point for the TF008 Plug Pack. The voltage of the plug pack being used must be 18 - 22 volts AC and rated at 1.3 Amps minimum for correct operation.
The + BATTERY connects to the red positive terminal of the battery and the - BATTERY connects to the black negative terminal of the battery. The battery should be a 12 volt sealed lead acid rechargeable type with a capacity of between 1.2 AH - 6.5 AH. The back-up battery is protected by a 3 Amp fuse.
The charging globe which is situated above the 3 Amp fuse will always be illuminated until the battery is
100% charged.
This group of terminals are the connection points for your system codepads. All system codepads should connect in a parallel configuration back to these terminals. The only factor restricting the number of codepads that can be connected is the available power and its distribution. Each codepad has a maximum power requirement of 60 mA with all indicators illuminated, therefore this should be taken into consideration when calculating your available continuous power. The total continuous external load on the system should not exceed 1 Amp maximum.
This group of terminals are the output interface terminals. They can be configured to any combination of the functions available via the system programming options. They can be used for a variety of functions with incredible flexibility. All outputs have a common terminal that is positive 12 volts and each output is capable of sinking a maximum of 400 mA. Output 1 is defaulted to operate a horn speaker.
The outputs are protected by EDM's unique Integrated Protection System, [IPS]. This makes them extremely tolerant to abuse or incorrect wiring. It should be noted that each output is open collector and will not source any current but can sink a maximum of 400 mA per output.
These relay contacts are fully programmable as with the strobe and output 1. The relay is factory defaulted as an alarm output (Sirens Running - Event Type 1,15).
The N/O contact is the connection point for the positive side of a DC siren such as a piezo screamer. The negative side of the DC siren needs to be connected to the GND terminal. A link (JP2) is provided on the PCB for connecting the COM terminal to either GND or 12V. This link should be connected to +12V as shown in "Figure 20: Solution 844/862/880 Wiring Diagram" on page 262. The relay is rated at 1
Amp/30 VDC.
These terminals are zones three and four. Their common terminal is +12V. All normally closed contacts are to be wired in series with the EOL resistor and where normally open contacts are to be wired in parallel with the EOL resistor. The function of the zones and their response times are programmable via the system programming options. If split EOL has been programmed, this will enable 24 hour zones or keyswitch zones to be connected in parallel to zones three and four to act as zones seven and eight.
These two terminals are for power to detectors and other equipment. They are fuse protected by a 1 amp fuse.
These terminals are zones one and two. Their common terminal is +12V. All normally closed contacts are to be wired in series with the EOL resistor and where normally open contacts are to be wired in parallel with the EOL resistor. The function of the zones and their response times are programmable via the system programming options. If split EOL has been programmed, this will enable 24 hour zones or keyswitch zones to be connected in parallel to zones one and two to act as zones five and six
ISSUE140 Electronics Design and Manufacturing Pty Limited
Terminals and Descriptions 259
(
_#"001<=(>;(37<G0(
37<G( F709<&5%&"'(
T#1<G(?"':&%&"'(
Is when your alarm system is armed and one of the detection devices are violated. A 24 hour zone
(e.g.. Smoke detector) may trigger when your system is armed or disarmed.
(
T'0D7<&'6(2194&'7(
V=5100(
Answering machine bypass has been incorporated so that it is possible to make a connection with the control panel for remote arming or remote programming operations when there is an answering machine or facsimile machine on the same telephone line.
(
T<G7:( a!=0%7G(>Eb(
(
When the system is in a state ready to accept alarms.
T$%"G1%&9(T<G&'6(
Automatic arming allows the system to automatically arm at the same time each day in AWAY
Mode or STAY Mode 1.
(
T$%"G1%&9(F&01<G&'6( Automatic disarming allows the system to automatically disarm at the same time each day in
AWAY Mode or STAY Mode 1.
(
TOT]("<(k(
(
TOT](2":7(
(
?":751:(
This is the button on your codepad used to execute any given command.
Is the mode used to arm your system when you leave your premises.
The codepad allows you to perform all functions such as arming, disarming and programming of your alarm system.
(
F1=(T#1<G(
Day alarm allows a combination of zones to be monitored while the system is in the disarmed state.
(
F7%79%"<0(
Are devices connected to your alarm system used to cause an alarm condition. Some common forms of detection devices are; passive infrared, smoke, photo electric beams, reed switches and
(
F&1##7<(
vibration sensors.
Is a device that is used for communicating to a monitoring station, mobile phone or pocket pager etc.
(
F&01<G7:(
(
F$1#(L75"<%&'6(
Is when your system is in a state that will not accept alarms except for 24 hour zones.
Dual reporting allows your control panel to transmit alarm signals in two different reporting formats (EG: The control panel may transmit to a monitoring station as well as a mobile phone etc or even to two different monitoring stations).
(
F='1G&9(V1%%7<=(
370%&'6(
(
HF2!T3( a!1%7##&%7(!&<7'b(
Is a feature used to monitor and test the condition of your backup battery.
Is a self contained siren unit complete with flashing blue strobe light and a backup battery. It offers a higher level of security for your alarm system.
H'%<=(3&G7("<(
H'%<=(F7#1=(
(
H'%<=(O1<'&'6(
Is the time allowed after entering your premises, to disarm your system before an alarm occurs.
Is the beeping from your codepad during entry time to remind you to disarm your system.
Electronics Design and Manufacturing Pty Limited ISSUE140
Solution 844/862/880
Installation Manual
37<G(
(
HI&%(3&G7("<(
HI&%(F7#1=(
F709<&5%&"'(
Is the amount of time you have to leave your premises after you have armed your system.
(
HI%7<'1#(H`$&5G7'%(
Is any device connected to your system such as detectors, codepads and sirens.
(
@"<97:(T<G&'6(
Is a situation where your alarm system is permitted to be armed when one or more zones are unsealed.
(
C1':"M7<(F7#1=(
When your system is armed and zone one is violated, the entry delay starts timing. If zone two is then violated the entry delay time is handed over to zone two and so on through zones three and
(
C1':(C7#:(L1:&"(
L7G"%7(?"'%<"#(
(
(\"9B"$%(F&1##7<(
(
\"9B"$%(!&<7'(
(
210%7<(?":7(
four. This is known as sequential hand over delay.
Hand held radio transmitters can be used to arm and disarm your system or cause a panic alarm.
Lockout dialler means that the dialler will only activate once per zone per arming cycle.
Lockout siren means that the sirens will only activate once per zone per arming cycle.
Is a numerical code used for arming and disarming the system as well as allowing access to all functions that are programmable through the codepad.
(
2"'&%"<&'6(!%1%&"'(
Is a secure location where a digital receiver monitors numerous alarm systems and deciphers their alarm transmission reports so that the operator can advise the appropriate authorities to take
(
K1'&9(
immediate action.
This is a type of alarm raised by you to indicate to the monitoring station that there is an emergency situation at your premises.
(
K4"'7(?"'%<"##7<(
Is a device used for arming your system via the telephone line. It is also used to acknowledge domestic alarm reports.
(
K1<%&%&"'&'6(
The
Solution 880
control panel may be set up to transform your single control panel and split the system into two separate controllable areas. Partitioning is extremely useful when you wish to secure sheds, dual occupancy dwellings, granny flats, shops and offices.
(
L1:&"(L7G"%7(Z07<(?":70( A radio user code that is used to arm and disarm the system remotely via hand held transmitters in
AWAY Mode or STAY Mode 1. Remote panic alarms are also allowed.
(
!71#7:(
Refers to a zones status. If a zone is sealed, the detection devices are not violated and the zone indicator will be extinguished (i.e.. a reed switch is closed or a detector is on stand by waiting for an intrusion).
(
!7'0"<(O1%94(
Sensor watch gives the control panel the ability to recognise that detection devices may have stopped working. This is a feature that monitors the operation of a zone over a programmed time
(
!'%(T#1<G(
period.
When programming your system, it is possible to have an individual zone for silent alarm. This means that when the zone is violated your alarm system will communicate with the monitoring station without sounding the sirens. This can only be programmed by your installer.
ISSUE140 Electronics Design and Manufacturing Pty Limited
Terminals and Descriptions 261
37<G(
!3T](2":7(N(
F709<&5%&"'(
Is a condition that automatically isolates certain zones when your system is armed in STAY Mode
1. These zones can only be programmed by your installer.
(
!3T](2":7(-(
Is a condition that automatically isolates certain zones when your system is armed in STAY Mode
2. These zones are programmed by the Master Code holder.
(
37#9"(T<G&'6(!7`$7'97( Telco arming is a feature that automatically diverts your telephone number to another telephone when the system is armed in AWAY Mode - same as using call forwarding.
(
37#9"(F&01<G(!7`$7'97( Telco disarm automatically un-diverts your telephone upon disarming your system.
(
Z'071#7:(
Refers to zone status. If a zone is unsealed, the detection devices are violated and the zone indicator will be illuminated (i.e.. a reed switch is open or a detector has noted an intrusion).
(
Z07<(?":7(
A numerical code that is used to arm and disarm the system in AWAY Mode, STAY Mode 1 or
STAY Mode 2.
(
J"'70(
A monitored input used to trigger an alarm condition. A zone may be set up only to activate an alarm when the system is armed or to operate irrespective of the system being armed or disarmed.
-*(C"$<(J"'7(
A monitored input where tamper switches and emergency switches may be connected. If at any time, (whether your system is armed or disarmed) one of these switches is violated, an alarm condition will be generated.
Electronics Design and Manufacturing Pty Limited ISSUE140
!"#$%&"'()**+),-+)).(O&<&'6(F&16<1G(
Solution 844/862/880
Installation Manual
Figure 20: Solution 844/862/880 Wiring Diagram
ISSUE140 Electronics Design and Manufacturing Pty Limited
Terminals and Descriptions
!"#$%&"'()**+),-+)).(?"G5"'7'%(>M7<#1=(
263
Figure 21: Solution 844/862/880 Component Overlay
Electronics Design and Manufacturing Pty Limited ISSUE140
37#79"G(?"''79%&"'(F&16<1G0(
Solution 844/862/880
Installation Manual
ISSUE140
Figure 22: Telecom Connection Diagrams For Solution 844/862/880
Electronics Design and Manufacturing Pty Limited
T557':&970(
Solution 844/862/880
Installation Manual
T557':&I(T(
37#754"'7(T'%&Yl1GG&'6(
There are many companies today importing American designed products that claim to have
Anti-Jamming and believe it or not, they push this feature as if it were a major break through in control panel technology. Well this in fact is not the case at all as most control panels have some sort of Anti-Jamming feature. We can go as far back as the early 1980's where even the
678 diallers incorporated a form of Anti-Jamming as a standard programmable option.
The important thing to note is that as most American designed products are primarily aimed at their local market and telephone networks, when they are imported to Australia their antijamming function does not perform as it should.
To clear up just what anti-jamming is and how it works needs some understanding of
Telephone Networks. In America either of the two parties (i.e.. the one who initiated the call or the one receiving the call) can clear the line by placing the hand piece back on the hook. If you pick up the hand piece again, dial tone will be received and you will be able to make a new call immediately. This is not so here in Australia.
In Australia, only the calling party can immediately terminate the call. If you receive a call from someone and hang up on them, picking the hand piece back up again to make a new call only reconnects you to the original caller. It will not be possible to make another call until the original caller hangs up or you hang up phone for ninety seconds or longer. So you see
Australia is very different and needs a special form of anti-jamming to suit our telephone network.
There are control panels on the market that after making a few call attempts which fail simply hang up and wait for ninety seconds or so, in an attempt to clear the jamming incoming call.
This may work in some instances where the caller is not a genuine burglar and is not deliberately trying to jam the control panel. With this simple method of hanging up for ninety seconds we have not only delayed the alarm signal for this time but also the time taken for the original failed call attempts which could easily total 4 minutes. This is bad enough in its own right but even more disturbing is the fact that the initial failed call attempts allow for the establishment of an audio connection between the would be burglar and the control panel.
Anyone with a little knowledge of alarm systems will be able to actually trick the dialler into thinking it is talking to a base station thus actually clearing the alarm signal. Pretty frightening when you thought the control panel you were using and recommending to your customers is supposed to have anti-jamming.
At Electronics Design and Manufacturing Pty Limited we take anti-jamming very seriously and have in fact devoted a great deal of time and money researching this problem. Our engineers have come up with the best possible anti-jamming procedure known and patented accordingly {Patent Number 571994}.
Our procedure is very simple and effective because we never answer the burglar’s phone call and the Telecom Network will automatically clear an unanswered call in approximately ninety seconds. This time will be even shorter if the call is originated through the Mobile-Net
Network where it will most likely be in the case of a true burglary.
Once the control panel detects that the phone line has stopped ringing it immediately loops the line and makes its call therefore transmitting its alarm message successfully. The line is also automatically disconnected from the telephones within the protected premises immediately on an alarm condition by the control panel to further confuse the burglar and eliminate the possibility of the burglar answering the call. As you can see, our method of anti-jamming will in the worst possible case delay the alarm signal by ninety seconds but even more importantly will never allow for an audio connection between the burglar and the control panel.
ISSUE140 Electronics Design and Manufacturing Pty Limited
Appendices
T557':&I(V(
267
All dialling products produced by Electronics Design and Manufacturing Pty Limited have incorporated this true anti-jamming feature as standard since 1985 and we do not consider it as an option but a must in any professional security system.
True anti-jamming can only be found in products produced by Electronics Design and
Manufacturing Pty Limited and any other manufacturer can only offer second best due to our patent on this very unique and effective procedure.
370%(L75"<%0(>'#=(O47'(T<G7:(
The
Solution 844/862/880
control panel allows for test reports to be transmitted to the base station receiver to verify that the dialler functional. So what you might say, as most alarm diallers allow you to do this.
The one problem with this is that installations that report opening and closing reports will generally also transmit a test report each day. This call is unnecessary, as a successful opening and closing report means that the dialler is functioning correctly.
The
Solution 844/862/880
control panel allows you to save time and money by providing test reports only while the system is in the armed state.
Program "LOCATION 428" on page 233 with Option 1 (Send test reports only if the system is armed), and then set the test report time to be in the middle of the day. During Monday to
Friday when the premises are generally open and the system disarmed a test report will not be transmitted. However, on the weekend, the premises will be closed and the system armed, so a test report will be transmitted at the programmed time thus verifying the operation of the dialler.
At first glance this may not seem to be a big deal but lets do a few sums and you will see just where savings can be made.
Let us assume that the customer wants, needs or has test reports programmed for once a day as well as opening and closing reports. This means that at least three phone calls will be made each week day and one call on Saturday and one call on Sunday.
By using the
Solution 844/862/880
control panel you will be able to eliminate five calls per week. This means that over one week you will save your customer $1.25 and over one year you will save them $65.00.
Not a bad saving, and remember these figures are for local calls only.
Turning the table slightly, a control room with lets say 1000 customers sending the above mentioned reports, can expect to receive some 884,000 phone calls ($221,000 assuming local calls) just for reporting opening, closing and test reports over a 12 month period.
If you use the
Solution 844/862/880
control panel, you can effectively cut the calls to
624,000 per year (at a value of $156,000 assuming local calls), a saving of $65,000. If we now assume that for each call one line is printed on the logging printer, and that one page is filled per 60 calls. You will be able to save 4333 sheets of paper per year and at approximately $45 per box this becomes a considerable saving.
As you can see using the
Solution 844/862/880
control panel will save you money, your customer money and will help conserve our natural resources, in fact, the only people who don't like this feature is Telecom.
Electronics Design and Manufacturing Pty Limited ISSUE140
Solution 844/862/880
Installation Manual
ISSUE140 Electronics Design and Manufacturing Pty Limited
!579&;&91%&"'0(
Solution 844/862/880
Installation Manual
O1<<1'%=(!%1%7G7'%(
Electronics Design and Manufacturing Pty Limited warrants this product to be free from defects in material and workmanship for a period of three years from the date of manufacture as indicated by the date stamp and /or the serial number on the product.
Defective units returned by the purchaser at their own expense during this period will be repaired or replaced at the option of the manufacturer. The repair or replacement will be free of charge provided that the defects were not incurred during shipping or handling, or the damage was not due to causes beyond the control of Electronics Design and Manufacturing Pty
Limited, such as lightning, excessive voltage, mechanical shock or damage arising out of abuse, alteration or improper application of the equipment.
]71<(-...(?"G5#&1'97(
This notice is to confirm that all
Solution 844/862/880
control panels are not susceptible to, or can be corrupted by the “Year 2000 Millennium Bug”.
To date, all
Solution
products that incorporate time keeping functions employ a rotating 100 year calendar. This means that the
Solution
products do not use the century in any time keeping algorithms, only the year within the century.
ISSUE140 Electronics Design and Manufacturing Pty Limited
Specifications
!579&;&91%&"'0(
271
37G57<1%$<7(L1'67i(
C$G&:&%=(
K"D7<(!"$<97i(
0 – 45 Degrees Celsius
10% - 95%
TF008 Plug Pack – 240 Volt / 18 Volt AC @ 1.3
Amp
65 mA
!%1':YV=(?$<<7'%i(
?$<<7'%(F<1D(/'(T#1<G(?"':&%&"'i(
115 mA
?$<<7'%(F<1D(O&%4(E"(T#1<G(1':(?":751:(@&%%7:i( 105 mA
V19BYZ5(V1%%7<=i(
F&G7'0&"'0i(
Ah / 12 Volt DC Rechargeable Sealed Lead Acid
Battery
306 mm x 262 mm x 84 mm (Packed In Carton)
O7&64%i(
!$55#&7<(?":7i(
E7D(J71#1':(37#757<G&%i(
2.5 Kg
N771
21#1=0&1(T55<"M1#(E$G87<i(
PTC 211/98/083 – Solution 880
PTC 211/98/084 – Solution 862
PTC 211/98/085 – Solution 844
Pending
LOCATION 999
!";%D1<7(P7<0&"'(E$G87<(
1.00
When using the Hand Held Programmer (CC814), you have the ability to display the software version number of the control panel. Refer to Command 999 - Display Panel Type Or
Software Version Number on page 46 for more information.
T:M&97(3"(Z07<0(
The Austel permit that has been issued for this product is subject to the following conditions.
•
The
Solution 844/862/880
Control Panel may only be powered by an EDM
TF008 Plug Pack (Approval Number Q92128).
Electronics Design and Manufacturing Pty Limited ISSUE140
Solution 844/862/880
Installation Manual
E7D(J71#1':(37#757<G&%(E"%70(
•
The grant of a telepermit for a device in no way indicates Telecom acceptance of responsibility for the correct operation of that device under all operating conditions.
•
This equipment shall not be used in any manner that could constitute a nuisance to other
Telecom customers.
•
Immediately disconnect this equipment should it become physically damaged and arrange for its disposal or repair.
•
The transmit level from this device is set at a fixed level and because of this there may be circumstances where the performance is less than optimal. Before reporting such occurrences as faults, please check the line with a standard telepermitted telephone and do not report a fault if the telephone performance is satisfactory.
•
This device is equipped with pulse dialling while the Telecom standard is DTMF tone dialling. There is no guarantee that Telecom lines will always continue to support pulse dialling.
Use of dialling, when this equipment is connected to the same line as other equipment, may give rise to bell tinkle or noise and may also cause a false answer condition.
Should such problems occur, the user should NOT contact the Telecom Faults Service.
•
•
•
This equipment is set up to carry out test calls at pre-determined times. Such test calls will interrupt any other calls that may be set up on the line at the same time. The timing set for such test calls should be discussed with the installer.
The timing set for test calls from this equipment may be subject to drift. If this proves to be inconvenient and your calls are interrupted, then the problem of timing should be discussed with the equipment installer. The matter should NOT be reported as a fault to
Telecom Faults Service.
This equipment shall not be set up to make automatic calls to the Telecom 111
Emergency Service.
This equipment should not be used under any circumstances that may constitute a nuisance to other Telecom customers.
In the event of any problem with this device, the systems battery, AC mains supply and telephone line should be disconnected. The user is to then arrange with the supplier of the device to make the necessary repairs.
Should the matter be reported to Telecom as a wiring fault and the fault be proven to be due to this product, a call-out charge will be incurred.
ISSUE140 Electronics Design and Manufacturing Pty Limited
(
!"#$%&"'()**(K<"6<1GG&'6(!477%0(
Solution 844/862/880
Installation Manual
Location 000 – 015
K<&G1<=(37#754"'7(E$G87<(@"<(L797&M7<(N
Location 016 – 031
!79"':1<=(37#754"'7(E$G87<(@"<(L797&M7<(N
Page 143
.( .( .( .( .( .( .( .( .( .( .( .( .( .( .( .(
Page 143
.( .( .( .( .( .( .( .( .( .( .( .( .( .( .( .(
Location 032
C1':041B7(3"'7(@"<((L797&M7<(N
Location 033
Location 034 – 039
Location 040 – 055
3<1'0G&00&"'(@"<G1%(@"<(L797&M7<(N(
!$809<&87<(/F(E$G87<(@"<(L797&M7<(N
1 = HI-LO Handshake (Contact ID)
2 = 1400 Hz (TX @ 1900 Hz)
3 = 2300 Hz (Low Speed Sescoa)
1 = Contact ID
2 = 4 + 2 Express
3 = FSK 300 Baud
4 = Domestic
K<&G1<=(37#754"'7(E$G87<(@"<(L797&M7<(-
4 = No Handshake Required
5 = Pager
Page 144
N(
Page 145
5 = Basic Pager
6 = Reserved
7 = Reserved
8 = Reserved
N
Page 145
.( .( .( .( .( .(
Page 145
.( .( .( .( .( .( .( .( .( .( .( .( .( .( .( .(
Location 056 – 071
!79"':1<=(37#754"'7(E$G87<(@"<(L797&M7<(-
Location 072
C1':041B7(3"'7(@"<(L797&M7<(-
Location 073
3<1'0G&00&"'(@"<G1%(@"<(L797&M7<(-(
Location 074 – 079
!$809<&87<(/F(E$G87<(@"<(L797&M7<(-
Page 146
.( .( .( .( .( .( .( .( .( .( .( .( .( .( .( .(
Page 148
1 = HI-LO Handshake (Contact ID)
2 = 1400 Hz (TX @ 1900 Hz)
3 = 2300 Hz (Low Speed Sescoa)
1 = Contact ID
2 = 4 + 2 Express
3 = FSK 300 Baud
4 = Domestic
4 = No Handshake Required
5 = Pager
5 = Basic Pager
6 = Reserved
7 = Reserved
8 = Reserved
N(
Page 148
N
Page 148
.( .( .( .( .( .(
Location 080
F&1##&'6(@"<G1%
(
Location 081 – 112
L707<M7:
1 = Australian DTMF (5 Digits/Second)
2 = Australian Decadic
3 = Alternate DTMF & Decadic (AUST)
Page 149
4 = International DTMF
5 = Reversed Decadic
6 = Alternate DTMF & Reversed Decadic
N(
Page 149
Location 113 –142
37#9"(T<G&'6(!7`$7'97(
Page 150
.( .( .( .( .( .( .( .( .( .( .( .( .( .( .( .( .( .( .( .( .( .( .( .( .( .( .( .( .( .(
Location 143 – 158
37#9"(F&01<G&'6(!7`$7'97
Page 151
.( .( .( .( .( .( .( .( .( .( .( .( .( .( .( .(
Location 159 – 174
?1##(V19B(37#754"'7(E$G87<
Location 175
L&'6(?"$'%
Location 176
37#754"'7(\&'7(@1$#%(>5%&"'0(
Page 151
.( .( .( .( .( .( .( .( .( .( .( .( .( .( .( .(
0 = Panel Will Not Answer
1 – 13 = No Of Rings Until Panel Answers
14 = Answering Machine Bypass 2
15 = Answering Machine Bypass 1
Page 152
)
Page 153
1 = Operate The FAULT Indicator When Telephone Line Fails
2 = Sound Speaker, Bell & Strobe When System Is Armed
4 = Sound Speaker, Bell & Strobe When System Is Disarmed
8 = Reserved
.
ISSUE140 Electronics Design and Manufacturing Pty Limited
Solution 844
Programming Sheets
(
Location 177
F&1##7<(>5%&"'0(N
Location 178
F&1##7<(>5%&"'0(-
Location 179
(
F&1##7<(>5%&"'0(Q
Location 180
T#1<G(\&'B(>5%&"'0(
1 = Dialler Reporting Functions Allowed
2 = Remote Arming Via The Telephone Allowed
4 = Answering Machine Bypass Only When Armed
8 = Use Bell 103 For FSK Format (Disabled – CCITT V21)
1 = Open/Close Reports Only If Previous Alarm
2 = Open/Close Reports For STAY Mode 1 and STAY Mode 2
4 = Delay Siren Until Transmission Complete
8 = Extend Time To Wait For Handshake From 30 Seconds To 55 Seconds
1 = Set DTMF Dialling Pulses To 1 Digit/Second
2 = Reserved
4 = Change Decadic Dialling To 60/40
8 = Reserved
275
Page 157
X
Page 158
.
Page 159
.
Page 129/160
Location 181 – 184
/'0%1##7<(?":7
1 = Upload/Download Allowed
2 = Call Back Phone Number Required For Upload/Download
4 = Exit Upload/Download Connection On Alarm
8 = External Modem Module (CC811) Required For Upload/Download
Q
Page 162
N( -( Q( *(
Page 163
Location 185 – 264
Z07<(?":70
( ( ( ( (
Z07<(?":7(N
Location 185 - 189
-( R( )( .( N.(
Z07<(?":7(-
Location 190 - 194
NR( NR( NR( NR( -(
Z07<(?":7(Q
Location 195 - 199
NR( NR( NR( NR( -(
Z07<(?":7(*
Z07<(?":7(,
(
L1:&"(?":7(X(
(
L1:&"(?":7(N-(
(
L1:&"(?":7(NR(
Location 210 - 214
NR( NR( NR( NR( -(
Location 225 - 229
NR( NR( NR( NR( -(
Location 240 - 244
NR( NR( NR( NR( -(
Location 255 - 259
NR( NR( NR( NR( -(
Z07<(?":7(S
(
L1:&"(?":7(N.(
(
L1:&"(?":7(NQ(
(
L1:&"(?":7(N,(
Location 200 - 204
NR( NR( NR( NR( -(
Z07<(?":7(R
Location 205 - 209
NR( NR( NR( NR( -(
Location 215 - 219
NR( NR( NR( NR( -(
Location 230 - 234
NR( NR( NR( NR( -(
Location 245 - 249
NR( NR( NR( NR( -(
Location 260 - 264
NR( NR( NR( NR( -(
Z07<(?":7()
(
L1:&"(?":7(NN(
(
L1:&"(?":7(N*(
(
(
Location 220 - 224
.( NR( NR( NR( Q(
Location 235 - 239
NR( NR( NR( NR( -(
Location 250 - 254
NR( NR( NR( NR( -(
( ( ( ( (
NR(((( NR ....(((( ((((
Z07<(?":7( K<&"<&%=(
K<&"<&%=(
0
1
2
3
4
Arm/Disarm
Arm Only
F709<&5%&"'(
Arm/Disarm + Open/Close Report
Arm Only + Close Report
Arm/Disarm + Code To Isolate
K<&"<&%=(
6
8
10
12
14
Table 156: User Code Priority Levels
F709<&5%&"'(
Arm/Disarm + Code To Isolate + Open/Close
Report
Arm/Disarm + Master Code Functions
Arm/Disarm + Master Code Functions +
Open/Close Report
Arm/Disarm + Master Code Functions + Code To
Isolate
Arm/Disarm + Master Code Functions + Code To
Isolate + Open/Close Report
Electronics Design and Manufacturing Pty Limited ISSUE140
Solution 844/862/880
Installation Manual
Location 265
F1=(T#1<G(J"'70
Location 266
H>\(L70&0%"<(P1#$7
1 = Zone 1
2 = Zone 2
0 = No End Of Line Resistor
1 = 1K
2 = 1K5
3 = 2K2
4 = 3K3
5 = 3K9
6 = 4K7
7 = 5K6
8 = 6K8
4 = Zone 3
8 = Zone 4
Page 168
.(
Page 170
9 = 10K
10 = 12K
11 = 22K
12 = Reserved
13 = Reserved
14 = Reserved
15 = Split EOL (3K3/6K8) – Four Burglary
Zones and Four 24 Hour Zones
NR
Page 174
Location 267 – 322
J"'70(
J"'7(N(
Location 267 - 273
J"'7(-(
Location 274 - 280
( ( ( ( ( ( ( ( ( -( .( .( N( N*( N( N( ( ( N( .( .( N( N*( N( N(
J"'7(Q(
Location 281 - 287
J"'7(*(
Location 288 - 294
J"'7(R(
Location 295 – 301
N( .( .( N( N*( N( N( ( ( .( .( .( N( N*( N( N( ( ( N-( .( .( N( N-( N( N(
J"'7(,(
Location 302 - 308
J"'7(S(
Location 309 - 315
J"'7()(
Location 316 - 322
N-( .( .( N( N-( N( N( ( ( NQ( .( .( N( N-( N( N( ( ( X( .( .( N( N-( N( N(
( ( ( ( ( ( (
J"'7(
3=57(
J"'7(K$#07(
?"$'%(
J"'7(K$#07(
?"$'%(3&G7(
J"'7(
>5%&"'(N(
J"'7(
>5%&"'(-(
L75"<%(
?":7(
F&1##7<(
>5%&"'0(
J"'7(3=570
There are fifteen different zone types to choose from. Each zone contains eight locations. Zones 1 to 4 are fully programmable whereas zones 5 to 8 may only be programmed to any 24 hour zone type.
J"'7(3=57( F709<&5%&"'( J"'7(3=57( F709<&5%&"'(
0
1
2
3
Instant
Handover
Delay-1
Delay-2
Reserved
8
9
10
11
24 Hour Hold-Up
24 Hour Tamper
Reserved
Keyswitch
24 Hour Burglary
4
5
6
7
Reserved
24 Hour Medical
24 Hour Panic
12
13
14
15
24 Hour Fire
Chime Only
Zone Not Used
Table 157: Available Zone Types
ISSUE140 Electronics Design and Manufacturing Pty Limited
Solution 844
Programming Sheets
J"'7(K$#07(?"$'%(!7%%&'60(
The pulse count settings for each zone can be programmed between 0 - 15.
J"'7(K$#07(?"$'%(3&G7(
Zone pulse count time is the time frame or period over which the number of pulses must register.
-.(G0(\""5(L705"'07(3&G7(
J"'7(K$#07(?"$'%(3&G7(
NR.(G0(\""5(L705"'07(3&G7(
J"'7(K$#07(?"$'%(3&G7(
0
0.5 Second
8
20 Seconds
1
1 Second
2 Seconds
9
30 Seconds
40 Seconds
2
3
4
3 Seconds
4 Seconds
5 Seconds
10
11
12
50 Seconds
60 Seconds
90 Seconds
5
6
7
10 Seconds
15 Seconds
13
14
15
120 Seconds
200 Seconds
Table 158: Zone Pulse Count Time Options
J"'7(>5%&"'0(N(
>5%&"'(
1
2
4
8
(
F709<&5%&"'(
Lockout Siren/Lockout Dialler
Delay Alarm Reporting
Silent Alarm
Sensor Watch
Table 159: Zone Options 1
(
J"'7(>5%&"'0(-(
>5%&"'(
1
2
4
8
F709<&5%&"'(
Isolated In STAY Mode 1
Zone Isolation Allowed
Forced Arming Allowed
Enable Zone Restore Report
Table 160: Zone Options 2
J"'7(F&1##7<(>5%&"'0
>5%&"'(
0
1
2
4
8
F709<&5%&"'(
No Report Required
Receiver 1
Receiver 2
Receiver 1 + 2
Receiver 2 Only When Receiver 1 Fails
277
Table 161: Zone Dialler Options
J"'7(F709<&5%&"'0(
Use this table as a reference to indicate what each zone is connected to.
J"'7( F709<&5%&"'( J"'7(
1 5
2
3
6
7
4 8
Table 162: Zone Descriptions
F709<&5%&"'(
Electronics Design and Manufacturing Pty Limited ISSUE140
Location 323
!D&'67<(!4$%:"D'(?"$'%(@"<(!&<7'(
Location 324
!D&'67<(!4$%:"D'(?"$'%(@"<(F&1##7<(
Location 325 – 326
J"'7(!%1%$0(Y(V=5100(L75"<%0(
Location 327 – 328
J"'7(!%1%$0(Y(3<"$8#7(L75"<%0
Location 329 – 330
J"'7(!%1%$0(Y(!7'0"<(O1%94(L75"<%0
Location 331
J"'7(!%1%$0(Y(T#1<G(L70%"<7(?":7(
Location 332
J"'7(!%1%$0(L75"<%&'6(>5%&"'0
Location 333 – 334
>57'+?#"07(L75"<%0
Location 335
>57'+?#"07(L75"<%&'6(>5%&"'0
Location 336
?":751:(F$<700(L75"<%
Location 337 – 338
?":751:(K1'&9(L75"<%
Location 339 – 340
?":751:(@&<7(L75"<%
Location 341 – 342
?":751:(27:&91#(L75"<%
Location 343
?":751:(L75"<%&'6(>5%&"'0
Location 325
Location 326
Location 327
Location 328
Location 329
Location 330
Solution 844/862/880
Installation Manual
Zone Bypass Report
Zone Bypass Restore Report
Zone Trouble Report
Zone Trouble Restore Report
Sensor Watch Report
Sensor Watch Restore Report
Page 185
Q
Page 186
,
Page 188
X( )(
Page 189
-( Q(
Page 190
*( R(
Page 190
N*(
Page 190
0 = No Report Required
1 = Receiver 1
2 = Receiver 2
4 = Receiver 1 + 2
8 = Receiver 2 Only When Receiver 1 Fails
Location 333
Location 334
Opening Report
Closing Report
N(
Page 191
NN( N-(
Page 191
0 = No Report Required
1 = Receiver 1
2 = Receiver 2
4 = Receiver 1 + 2
8 = Receiver 2 Only When Receiver 1 Fails
N(
Page 192
,(
Page 192
S( NR(
Page 193
S( N*(
Page 193
S( NQ(
Page 194
0 = No Report Required
1 = Receiver 1
2 = Receiver 2
4 = Receiver 1 + 2
8 = Receiver 2 Only When Receiver 1 Fails
N(
ISSUE140 Electronics Design and Manufacturing Pty Limited
Solution 844
Programming Sheets
Location 344 – 345
!=0%7G(!%1%$0(c(@$07(@1&#(L75"<%(
Location 346 – 347
!=0%7G(!%1%$0(c(@$07(@1&#(L70%"<7(L75"<%(
279
Location 348 – 349
!=0%7G(!%1%$0
(c
T?(@1&#(L75"<%(
Location 350 – 351
!=0%7G(!%1%$0(Y(T?(@1&#(L70%"<7(L75"<%(
Location 352 – 353
!=0%7G(!%1%$0(Y(\"D(V1%%7<=(L75"<%
Location 354 – 355
!=0%7G(!%1%$0(Y(\"D(V1%%7<=(L70%"<7(L75"<%
Location 356 – 358
!=0%7G(!%1%$0(c(T99700(F7'&7:
Location 359
!=0%7G(!%1%$0(L75"<%&'6(>5%&"'0
Location 360 – 366
370%(L75"<%&'6(3&G7
Location 367
370%(L75"<%&'6(F&1##7<(>5%&"'0(
Location 356
Location 357
Location 358
Code Retries
Reporting Code – Tens Digit
Reporting Code – Units Digit
0 = No Report Required
1 = Receiver 1
2 = Receiver 2
4 = Receiver 1 + 2
8 = Receiver 2 Only When Receiver 1 Fails
Location 360
Location 361
Location 362
Location 363
Location 364
Location 365
Location 366
Actual Hour Of The Day (Tens Digit)
Actual Hour Of The Day (Units Digit)
Actual Minute Of The Day (Tens Digit)
Actual Minute Of The Day (Units Digit)
Test Report Code (Tens Digit)
Test Report Code (Units Digit)
Repeat Interval In Days
0 = No Report Required
1 = Receiver 1
2 = Receiver 2
4 = Receiver 1 + 2
8 = Receiver 2 Only When Receiver 1 Fails
Location 368 – 397
>$%5$%((
?"';&6$<1%&"'0
>$%5$%(N
L7#1=(
Location 368 - 373
N( N*( .( .( .( .(
>$%5$%(-
Location 374 - 379
-( S( N.( -( N( R(
Default For
Horn Speaker
Location 386 – 391
N( NR( N( .( .( .(
?":751:(
Default For
Fire Alarm Verification
Location 392 – 397
.( NQ( -( N( .( N(
Default For
Sirens Running
Default For Entry/Exit
Warning + Day Alarm
!%<"87
(
HM7'%(3=57( K"#1<&%=( 3&G7(V107( 3&G7(2$#%&5#&7<(
,( S( N-(
Page 198
N(
Page 198
.( .( .( .( S( N( .(
Page 199
N(
Page 202
Location 380 - 385
-( .( ,( *( .( )(
Default For Strobe
(Reset In 8 Hrs)
( ( ( ( ( (
Page 194
N.( Q(
Page 194
N.( )(
Page 195
N.( -(
Page 195
N.( S(
Page 196
N.( N(
Page 196
N.( ,(
Page 197
Electronics Design and Manufacturing Pty Limited ISSUE140
Location 398 – 399
H'%<=(3&G7<(N
Location 400 – 401
H'%<=(3&G7<(-
Location 402 – 403
HI&%(3&G7
Location 404 – 405
H'%<=(_$1<:(3&G7(@"<(!3T](2":7(
Location 406 – 407
F7#1=(T#1<G(L75"<%&'6(3&G7(
Location 408 – 409
!7'0"<(O1%94(3&G7
Location 410
?":751:(\"9B"$%(3&G7
Location 398
Location 399
Location 400
Location 401
Location 402
Location 403
Location 404
Location 405
Location 406
Location 407
Location 408
Location 409
Location 410
Location 411
!&<7'(L$'(3&G7
Location 413
T$%"(T<G&'6(K<7YT#7<%(3&G7(
Location 411
Location 412
!&<7'(!"$':(L1%7(a!#"D(mY!"$':Yn(@10%b
Location 413
Location 414 – 417
T$%"(T<G&'6(3&G7
Location 418 – 421
T$%"(F&01<G&'6(3&G7
Location 422
U&00Y>;;(O1&%(3&G7(
Location 423
L707<M7:
Location 414
Location 415
Location 416
Location 417
Location 418
Location 419
Location 420
Location 421
Location 422
Solution 844/862/880
Installation Manual
Increments Of 1 Second (0 - 15 Sec’s)
Increments Of 16 Seconds (0 - 240 Sec’s)
Increments Of 1 Second (0 - 15 Sec’s)
Increments Of 16 Seconds (0 - 240 Sec’s)
Increments Of 1 Second (0 - 15 Sec’s)
Increments Of 16 Seconds (0 - 240 Sec’s)
Increments Of 1 Second (0 - 15 Sec’s)
Increments Of 16 Seconds (0 - 240 Sec’s)
Increments Of 1 Second (0 - 15 Sec’s)
Increments Of 16 Seconds (0 - 240 Sec’s)
Increments Of Days (Tens Digit)
Increments Of Days (Units Digit)
Increments Of 10 Seconds
Increments Of 1 Minute (0 – 15 Min’s)
Increments Of 5 Minutes
Page 218
*( N(
Page 218
)( -(
Page 219
N-( Q(
Page 219
.( .(
Page 219
.( .(
Page 220
.( .(
Page 220
.
Page 221
R
Page 221
S
Page 222
N
Page 222
(
Hour Of The Day (Tens Digit)
Hour Of The Day (Units Digit)
Minute Of The Day (Tens Digit)
Minute Of The Day (Units Digit)
.( .( .( .(
Page 223
(
Hour Of The Day (Tens Digit)
Hour Of The Day (Units Digit)
Minute Of The Day (Tens Digit)
Minute Of The Day (Units Digit)
Increments Of 500 ms (500 ms – 8 Sec’s)
.( .( .( .(
Page 223
Q(
Page 223
.
ISSUE140 Electronics Design and Manufacturing Pty Limited
Solution 844
Programming Sheets
Location 424
!=0%7G(>5%&"'0(N
Location 425
!=0%7G(>5%&"'0(-(
Location 426
!=0%7G(>5%&"'0(Q
Location 427
!=0%7G(>5%&"'0(*
Location 428
?"'0$G7<(>5%&"'0(N
Location 429
?"'0$G7<(>5%&"'0(-
Location 430
?"'0$G7<(>5%&"'0(Q
Location 431
L1:&"(/'5$%(>5%&"'0
Location 748 - 749
L&'6(V$<0%(?"$'%
Location 900
F&018#7(@19%"<=(F7;1$#%(
Location 901 – 904
!=0%7G(3&G7
Location 905 – 910
!=0%7G(F1%7(
1 = EDM Smart Lockout Allowed
2 = Horn Speaker Monitor
4 = Strobe Indications For Radio Arm/Disarm
8 = Horn Speaker Beeps For Radio Arm/Disarm
1 = Codepad Panic To Be Silent
2 = Codepad Fire To Be Silent
4 = Codepad Medical To Be Silent
8 = Access Denied (Code Retries) To Be Silent
1 = AC Fail In 1 Hour (Disabled = After 2 Minutes)
2 = Ignore AC Fail
4 = Pulse Count Handover Allowed
8 = Handover Delay To Be Sequential
1 = Panel To Power Up Disarmed (If Power Reset)
2 = Arm/Disarm Tracking On Power Up
4 = Internal Crystal To Keep Time
8 = Keyswitch Interface, Night Arm Station Or RE005 Installed
1 = Test Reports Only When Armed
2 = Test Report After Siren Reset
4 = Auto Arm In STAY Mode 1
8 = STAY Indicator To Display Day Alarm Status
1 = Codepad Display Extinguish After 60 Seconds
2 = Single Button Arming Allowed (AWAY, STAY Mode 1 & 2)
4 = Single Button Disarming Allowed (STAY Mode 1 & 2)
8 = Alarm Memory Reset On Disarm
1 = Codepad Fault Alarm Beeps Allowed
2 = Use Digit 3 For Codepad Duress Instead Of Digit 9
4 = Alarms Activate Siren & Strobe Outputs In STAY Mode 1 & 2
8 = Reserved
1 = Radio Receiver (WE800)
2 = Latching Keyswitch Input
3 = Momentary Keyswitch Input
4 = Reserved
Location 748
Location 749
Location 901
Location 902
Location 903
Location 904
Location 905
Location 906
Location 907
Location 908
Location 909
Location 910
Increments Of 5 ms
Increments Of 80 ms
0 = Defaulting Enabled
15 = Defaulting Disabled
Hour Of The Day (Tens Digit)
Hour Of The Day (Units Digit)
Minute Of The Day (Tens Digit)
Minute Of The Day (Units Digit)
Day Of The Month (Tens Digit)
Day Of The Month (Units Digit)
Month Of The Year (Tens Digit)
Month Of The Year (Units Digit)
Year (Tens Digit)
Year (Units Digit)
281
Page 229
N
Page 230
.
Page 231
)
Page 232
.
Page 233
.
Page 234
-
Page 235
R
Page 236
.
Page 154
*( ,(
Page 47
.
Page 225
.( .( .( .(
Page 226
.( N( .( N( .( N(
Electronics Design and Manufacturing Pty Limited ISSUE140
Solution 844/862/880
Installation Manual
ISSUE140 Electronics Design and Manufacturing Pty Limited
(
!"#$%&"'(),-(K<"6<1GG&'6(!477%0(
Solution 844/862/880
Installation Manual
Location 000 – 015
K<&G1<=(37#754"'7(E$G87<(@"<(L797&M7<(N
Location 016 – 031
!79"':1<=(37#754"'7(E$G87<(@"<(L797&M7<(N
Page 143
.( .( .( .( .( .( .( .( .( .( .( .( .( .( .( .(
Page 143
.( .( .( .( .( .( .( .( .( .( .( .( .( .( .( .(
Location 032
C1':041B7(3"'7(@"<((L797&M7<(N
Location 033
Location 034 – 039
Location 040 – 055
3<1'0G&00&"'(@"<G1%(@"<(L797&M7<(N(
!$809<&87<(/F(E$G87<(@"<(L797&M7<(N
1 = HI-LO Handshake (Contact ID)
2 = 1400 Hz (TX @ 1900 Hz)
3 = Reserved
1 = Contact ID
2 = 4 + 2 Express
3 = FSK 300 Baud
4 = Domestic
K<&G1<=(37#754"'7(E$G87<(@"<(L797&M7<(-
4 = No Handshake Required
5 = Pager
Page 144
N(
Page 145
5 = Basic Pager
6 = Reserved
7 = Reserved
8 = Reserved
N
Page 145
.( .( .( .( .( .(
Page 145
.( .( .( .( .( .( .( .( .( .( .( .( .( .( .( .(
Location 056 – 071
!79"':1<=(37#754"'7(E$G87<(@"<(L797&M7<(-
Location 072
C1':041B7(3"'7(@"<(L797&M7<(-
Location 073
3<1'0G&00&"'(@"<G1%(@"<(L797&M7<(-(
Location 074 – 079
!$809<&87<(/F(E$G87<(@"<(L797&M7<(-
Page 146
.( .( .( .( .( .( .( .( .( .( .( .( .( .( .( .(
Page 148
1 = HI-LO Handshake (Contact ID)
2 = 1400 Hz (TX @ 1900 Hz)
3 = 2300 Hz (Low Speed Sescoa)
1 = Contact ID
2 = 4 + 2 Express
3 = FSK 300 Baud
4 = Domestic
4 = No Handshake Required
5 = Pager
5 = Basic Pager
6 = Reserved
7 = Reserved
8 = Reserved
N(
Page 148
N
Page 148
.( .( .( .( .( .(
Location 080
F&1##&'6(@"<G1%
(
Location 081 – 112
L707<M7:
1 = Australian DTMF (5 Digits/Second)
2 = Australian Decadic
3 = Alternate DTMF & Decadic (AUST)
Page 149
4 = International DTMF
5 = Reversed Decadic
6 = Alternate DTMF & Reversed Decadic
N(
Page 149
Location 113 –142
37#9"(T<G&'6(!7`$7'97(
Page 150
.( .( .( .( .( .( .( .( .( .( .( .( .( .( .( .( .( .( .( .( .( .( .( .( .( .( .( .( .( .(
Location 143 – 158
37#9"(F&01<G&'6(!7`$7'97
Page 151
.( .( .( .( .( .( .( .( .( .( .( .( .( .( .( .(
Location 159 – 174
?1##(V19B(37#754"'7(E$G87<
Location 175
L&'6(?"$'%
Location 176
37#754"'7(\&'7(@1$#%(>5%&"'0(
Page 151
.( .( .( .( .( .( .( .( .( .( .( .( .( .( .( .(
0 = Panel Will Not Answer 14 = Answering Machine Bypass 2
1 – 13 = No Of Rings Until Panel Answers 15 = Answering Machine Bypass 1
Page 152
)
Page 153
1 = Display FAULT Indicator When Telephone Line Fails
2 = Sound Alarm When System Is Armed
4 = Sound Alarm When System Is Disarmed
8 = Reserved
.
ISSUE140 Electronics Design and Manufacturing Pty Limited
Solution 862
Programming Sheets
(
Location 177
F&1##7<(>5%&"'0(N
Location 178
F&1##7<(>5%&"'0(-
(
Location 179
F&1##7<(>5%&"'0(Q
Location 180
T#1<G(\&'B(>5%&"'0(
1 = Dialler Reporting Functions Allowed
2 = Remote Arming Via The Telephone Allowed
4 = Answering Machine Bypass Only When Armed
8 = Use Bell 103 For FSK Format (Disabled – CCITT V21)
1 = Open/Close Reports Only If Previous Alarm
2 = Open/Close Reports For STAY Mode 1 and STAY Mode 2
4 = Delay Siren Until Transmission Complete
8 = Extend Time To Wait For Handshake From 30 Seconds To 55 Seconds
1 = Set DTMF Dialling Pulses To 1 Digit/Second
2 = Reserved
4 = Change Decadic Dialling To 60/40
8 = Reserved
285
Page 157
X
Page 158
.
Page 159
.
Page 129/160
Location 181 – 184
/'0%1##7<(?":7
1 = Upload/Download Allowed
2 = Call Back Phone Number Required For Upload/Download
4 = Exit Upload/Download Connection On Alarm
8 = External Modem Module (CC811) Required For Upload/Download
Q
Page 162
N( -( Q( *(
Page 163
Location 185 – 264
Z07<(?":70
Z07<(?":7(Q
( ( ( ( (
Location 195 - 199
NR( NR( NR( NR( -(
Z07<(?":7(N
Z07<(?":7(*
Location 185 - 189
-( R( )( .( N.(
Location 200 - 204
NR( NR( NR( NR( -(
Z07<(?":7(-
Z07<(?":7(R
Location 190 - 194
NR( NR( NR( NR( -(
Location 205 - 209
NR( NR( NR( NR( -(
Z07<(?":7(,
(
L1:&"(?":7(X(
(
L1:&"(?":7(N-(
(
L1:&"(?":7(NR(
Location 210 - 214
NR( NR( NR( NR( -(
Location 225 - 229
NR( NR( NR( NR( -(
Location 240 - 244
NR( NR( NR( NR( -(
Location 255 - 259
NR( NR( NR( NR( -(
Z07<(?":7(S
(
L1:&"(?":7(N.(
(
L1:&"(?":7(NQ(
(
L1:&"(?":7(N,(
Location 215 - 219
NR( NR( NR( NR( -(
Location 230 - 234
NR( NR( NR( NR( -(
Location 245 - 249
NR( NR( NR( NR( -(
Location 260 - 264
NR( NR( NR( NR( -(
Z07<(?":7()
(
L1:&"(?":7(NN(
(
L1:&"(?":7(N*(
(
(
Location 220 - 224
.( NR( NR( NR( Q(
Location 235 - 239
NR( NR( NR( NR( -(
Location 250 - 254
NR( NR( NR( NR( -(
( ( ( ( (
NR(((( NR ....(((( ((((
Z07<(?":7( K<&"<&%=(
K<&"<&%=(
0
1
2
3
4
Arm/Disarm
Arm Only
F709<&5%&"'(
Arm/Disarm + Open/Close Report
Arm Only + Close Report
Arm/Disarm + Code To Isolate
K<&"<&%=(
6
8
10
12
14
Table 163: User Code Priority Levels
F709<&5%&"'(
Arm/Disarm + Code To Isolate + Open/Close
Report
Arm/Disarm + Master Code Functions
Arm/Disarm + Master Code Functions +
Open/Close Report
Arm/Disarm + Master Code Functions + Code To
Isolate
Arm/Disarm + Master Code Functions + Code To
Isolate + Open/Close Report
Electronics Design and Manufacturing Pty Limited ISSUE140
Solution 844/862/880
Installation Manual
Location 265
F1=(T#1<G(J"'70
Location 266
H>\(L70&0%"<(P1#$7
1 = Zone 1
2 = Zone 2
0 = No End Of Line Resistor
1 = 1K
2 = 1K5
3 = 2K2
4 = 3K3
5 = 3K9
6 = 4K7
7 = 5K6
8 = 6K8
4 = Zone 3
8 = Zone 4
Page 168
.(
Page 170
9 = 10K
10 = 12K
11 = 22K
12 = Reserved
13 = Reserved
14 = Reserved
15 = Split EOL (3K3/6K8) – Six Burglary
Zones and Two 24 Hour Zones
NR
Page 173
Location 267 – 322
J"'70(
J"'7(N(
Location 267 - 273
J"'7(-(
Location 274 - 280
( ( ( ( ( ( ( ( ( -( .( .( N( N*( N( N( ( ( N( .( .( N( N*( N( N(
J"'7(Q(
Location 281 - 287
J"'7(*(
Location 288 - 294
J"'7(R(
Location 295 – 301
N( .( .( N( N*( N( N( ( ( N( .( .( N( N*( N( N( ( ( .( .( .( N( N*( N( N(
J"'7(,(
Location 302 - 308
J"'7(S(
Location 309 - 315
J"'7()(
Location 316 - 322
.( .( .( N( N*( N( N( ( ( NQ( .( .( N( N-( N( N( ( ( X( .( .( N( N-( N( N(
( ( ( ( ( ( (
J"'7(
3=57(
J"'7(K$#07(
?"$'%(
J"'7(K$#07(
?"$'%(3&G7(
J"'7(
>5%&"'(N(
J"'7(
>5%&"'(-(
L75"<%(
?":7(
F&1##7<(
>5%&"'0(
J"'7(3=570
There are fifteen different zone types to choose from. Each zone contains eight locations. Zones 1 to 6 are fully programmable whereas zones 7 and 8 may only be programmed to any 24 hour zone type.
J"'7(3=57( F709<&5%&"'( J"'7(3=57(
0
Instant
8
F709<&5%&"'(
24 Hour Hold-Up
1
2
3
4
Handover
Delay-1
Delay-2
Reserved
Reserved
9
10
11
12
24 Hour Tamper
Reserved
Keyswitch
24 Hour Burglary
24 Hour Fire
5
6
7
24 Hour Medical
24 Hour Panic
13
14
15
Chime Only
Zone Not Used
Table 164: Available Zone Types
ISSUE140 Electronics Design and Manufacturing Pty Limited
Solution 862
Programming Sheets
J"'7(K$#07(?"$'%(!7%%&'60
The pulse count settings for each zone can be programmed between 0 - 15.
J"'7(K$#07(?"$'%(3&G7
Zone pulse count time is the time frame or period over which the number of pulses must register.
-.(G0(\""5(L705"'07(3&G7(
J"'7(K$#07(?"$'%(3&G7(
NR.(G0(\""5(L705"'07(3&G7(
J"'7(K$#07(?"$'%(3&G7(
0
0.5 Second
8
20 Seconds
1
2
3
4
1 Second
2 Seconds
3 Seconds
4 Seconds
9
10
11
12
30 Seconds
40 Seconds
50 Seconds
60 Seconds
5 Seconds 90 Seconds
5
6
7
10 Seconds
15 Seconds
13
14
15
120 Seconds
200 Seconds
Table 165: Zone Pulse Count Time Options
J"'7(>5%&"'0(N(
>5%&"'(
1
2
4
8
(
F709<&5%&"'(
Lockout Siren/Lockout Dialler
Delay Alarm Reporting
Silent Alarm
Sensor Watch
Table 166: Zone Options 1
(
J"'7(>5%&"'0(-(
>5%&"'(
1
2
4
8
F709<&5%&"'(
Isolated In STAY Mode 1
Zone Isolation Allowed
Forced Arming Allowed
Enable Zone Restore Report
Table 167: Zone Options 2
J"'7(F&1##7<(>5%&"'0(
>5%&"'(
0
1
2
4
8
F709<&5%&"'(
No Report Required
Receiver 1
Receiver 2
Receiver 1 + 2
Receiver 2 Only When Receiver 1 Fails
287
Table 168: Zone Dialler Options
J"'7(F709<&5%&"'0
Use this table as a reference to indicate what each zone is connected to.
J"'7( F709<&5%&"'( J"'7(
1 5
2
3
6
7
4 8
Table 169: Zone Descriptions
F709<&5%&"'(
Electronics Design and Manufacturing Pty Limited ISSUE140
Location 323
!D&'67<(!4$%:"D'(?"$'%(@"<(!&<7'(
Location 324
!D&'67<(!4$%:"D'(?"$'%(@"<(F&1##7<(
Location 325 – 326
J"'7(!%1%$0(Y(V=5100(L75"<%0(
Location 327 – 328
J"'7(!%1%$0(Y(3<"$8#7(L75"<%0
Location 329 – 330
J"'7(!%1%$0(Y(!7'0"<(O1%94(L75"<%0
Location 331
J"'7(!%1%$0(Y(T#1<G(L70%"<7(?":7(
Location 332
J"'7(!%1%$0(L75"<%&'6(>5%&"'0
Location 333 – 334
>57'+?#"07(L75"<%0
Location 335
>57'+?#"07(L75"<%&'6(>5%&"'0
Location 336
?":751:(F$<700(L75"<%
Location 337 – 338
?":751:(K1'&9(L75"<%
Location 339 – 340
?":751:(@&<7(L75"<%
Location 341 – 342
?":751:(27:&91#(L75"<%
Location 343
?":751:(L75"<%&'6(>5%&"'0
Location 325
Location 326
Location 327
Location 328
Location 329
Location 330
Solution 844/862/880
Installation Manual
Zone Bypass Report
Zone Bypass Restore Report
Zone Trouble Report
Zone Trouble Restore Report
Sensor Watch Report
Sensor Watch Restore Report
Page 185
Q
Page 186
,
Page 188
X( )(
Page 189
-( Q(
Page 190
*( R(
Page 190
N*(
Page 190
0 = No Report Required
1 = Receiver 1
2 = Receiver 2
4 = Receiver 1 + 2
8 = Receiver 2 Only When Receiver 1 Fails
Location 333
Location 334
Opening Report
Closing Report
N(
Page 191
NN( N-(
Page 191
0 = No Report Required
1 = Receiver 1
2 = Receiver 2
4 = Receiver 1 + 2
8 = Receiver 2 Only When Receiver 1 Fails
N(
Page 192
,(
Page 192
S( NR(
Page 193
S( N*(
Page 193
S( NQ(
Page 194
0 = No Report Required
1 = Receiver 1
2 = Receiver 2
4 = Receiver 1 + 2
8 = Receiver 2 Only When Receiver 1 Fails
N(
ISSUE140 Electronics Design and Manufacturing Pty Limited
Solution 862
Programming Sheets
Location 344 – 345
!=0%7G(!%1%$0(c(@$07(@1&#(L75"<%(
Location 346 – 347
!=0%7G(!%1%$0(c(@$07(@1&#(L70%"<7(L75"<%(
Location 348 – 349
!=0%7G(!%1%$0
(c
T?(@1&#(L75"<%
Location 350 – 351
!=0%7G(!%1%$0(Y(T?(@1&#(L70%"<7(L75"<%(
Location 352 – 353
!=0%7G(!%1%$0(Y(\"D(V1%%7<=(L75"<%
Location 354 – 355
!=0%7G(!%1%$0(Y(\"D(V1%%7<=(L70%"<7(L75"<%
Location 356 – 358
!=0%7G(!%1%$0(c(T99700(F7'&7:
Location 359
!=0%7G(!%1%$0(L75"<%&'6(>5%&"'0
Location 360 – 366
370%(L75"<%&'6(3&G7
Location 367
370%(L75"<%&'6(F&1##7<(>5%&"'0(
Location 356
Location 357
Location 358
Code Retries
Reporting Code – Tens Digit
Reporting Code – Units Digit
0 = No Report Required
1 = Receiver 1
2 = Receiver 2
4 = Receiver 1 + 2
8 = Receiver 2 Only When Receiver 1 Fails
Location 360
Location 361
Location 362
Location 363
Location 364
Location 365
Location 366
Actual Hour Of The Day (Tens Digit)
Actual Hour Of The Day (Units Digit)
Actual Minute Of The Day (Tens Digit)
Actual Minute Of The Day (Units Digit)
Test Report Code (Tens Digit)
Test Report Code (Units Digit)
Repeat Interval In Days
0 = No Report Required
1 = Receiver 1
2 = Receiver 2
4 = Receiver 1 + 2
8 = Receiver 2 Only When Receiver 1 Fails
Location 368 – 397
>$%5$%((
?"';&6$<1%&"'0
>$%5$%(N
L7#1=(
Location 368 - 373
N( N*( .( .( .( .(
>$%5$%(-
Location 374 - 379
-( S( N.( -( N( R(
Default For
Horn Speaker
Location 386 – 391
N( NR( N( .( .( .(
Default For
Sirens Running
?":751:(
Default For
Fire Alarm Verification
Location 392 – 397
.( NQ( -( N( .( N(
Default For Entry/Exit
Warning + Day Alarm
!%<"87
(
HM7'%(3=57( K"#1<&%=( 3&G7(V107( 3&G7(2$#%&5#&7<(
289
N(
Page 202
Location 380 - 385
-( .( ,( *( .( )(
Default For Strobe
(Reset In 8 Hrs)
( ( ( ( ( (
Page 194
N.( Q(
Page 194
N.( )(
Page 195
N.( -(
Page 195
N.( S(
Page 196
N.( N(
Page 197
N.( ,(
Page 197
,( S( N-(
Page 198
N(
Page 198
.( .( .( .( S( N( .(
Page 199
Electronics Design and Manufacturing Pty Limited ISSUE140
Location 398 – 399
H'%<=(3&G7<(N
Location 400 – 401
H'%<=(3&G7<(-
Location 402 – 403
HI&%(3&G7
Location 404 – 405
H'%<=(_$1<:(3&G7(@"<(!3T](2":7(
Location 406 – 407
F7#1=(T#1<G(L75"<%&'6(3&G7(
Location 408 – 409
!7'0"<(O1%94(3&G7
Location 410
?":751:(\"9B"$%(3&G7
Location 398
Location 399
Location 400
Location 401
Location 402
Location 403
Location 404
Location 405
Location 406
Location 407
Location 408
Location 409
Location 410
Location 411
!&<7'(L$'(3&G7
Location 413
T$%"(T<G&'6(K<7YT#7<%(3&G7(
Location 411
Location 412
!&<7'(!"$':(L1%7(a!#"D(mY!"$':Yn(@10%b
Location 413
Location 414 – 417
T$%"(T<G&'6(3&G7
Location 418 – 421
T$%"(F&01<G&'6(3&G7
Location 422
U&00Y>;;(O1&%(3&G7(
Location 423
L707<M7:
Location 414
Location 415
Location 416
Location 417
Location 418
Location 419
Location 420
Location 421
Location 422
Solution 844/862/880
Installation Manual
Increments Of 1 Second (0 - 15 Sec’s)
Increments Of 16 Seconds (0 - 240 Sec’s)
Increments Of 1 Second (0 - 15 Sec’s)
Increments Of 16 Seconds (0 - 240 Sec’s)
Increments Of 1 Second (0 - 15 Sec’s)
Increments Of 16 Seconds (0 - 240 Sec’s)
Increments Of 1 Second (0 - 15 Sec’s)
Increments Of 16 Seconds (0 - 240 Sec’s)
Increments Of 1 Second (0 - 15 Sec’s)
Increments Of 16 Seconds (0 - 240 Sec’s)
Increments Of Days (Tens Digit)
Increments Of Days (Units Digit)
Increments Of 10 Seconds
Increments Of 1 Minute (0 – 15 Min’s)
Increments Of 5 Minutes
Page 218
*( N(
Page 218
)( -(
Page 219
N-( Q(
Page 219
.( .(
Page 219
.( .(
Page 220
.( .(
Page 220
.
Page 221
R
Page 221
S
Page 222
N
Page 222
(
Hour Of The Day (Tens Digit)
Hour Of The Day (Units Digit)
Minute Of The Day (Tens Digit)
Minute Of The Day (Units Digit)
.( .( .( .(
Page 223
(
Hour Of The Day (Tens Digit)
Hour Of The Day (Units Digit)
Minute Of The Day (Tens Digit)
Minute Of The Day (Units Digit)
Increments Of 500 ms (500 ms – 8 Sec’s)
.( .( .( .(
Page 223
Q(
Page 223
.
ISSUE140 Electronics Design and Manufacturing Pty Limited
Solution 862
Programming Sheets
Location 424
!=0%7G(>5%&"'0(N
Location 425
!=0%7G(>5%&"'0(-(
Location 426
!=0%7G(>5%&"'0(Q
Location 427
!=0%7G(>5%&"'0(*
Location 428
?"'0$G7<(>5%&"'0(N
Location 429
?"'0$G7<(>5%&"'0(-
Location 430
?"'0$G7<(>5%&"'0(Q
Location 431
L1:&"(/'5$%(>5%&"'0
Location 748 - 749
L&'6(V$<0%(?"$'%
Location 900
F&018#7(@19%"<=(F7;1$#%(
Location 901 – 904
!=0%7G(3&G7
Location 905 – 910
!=0%7G(F1%7(
1 = EDM Smart Lockout Allowed
2 = Horn Speaker Monitor
4 = Strobe Indications For Radio Arm/Disarm
8 = Horn Speaker Beeps For Radio Arm/Disarm
1 = Codepad Panic To Be Silent
2 = Codepad Fire To Be Silent
4 = Codepad Medical To Be Silent
8 = Access Denied To Be Silent
1 = AC Fail After 1 Hour (Disabled = After 2 Minutes)
2 = Ignore AC Fail
4 = Pulse Count Handover Allowed
8 = Handover Delay To Be Sequential
1 = Panel To Power Up In The Disarmed (If Power Reset)
2 = Arm/Disarm Tracking On Power Up
4 = Internal Crystal To Keep Time
8 = Keyswitch Interface, Night Arm Station Or RE005 Installed
1 = Test Reports Only When Armed
2 = Test Report After Siren Reset
4 = Auto Arm In STAY Mode 1
8 = STAY Indicator To Display Day Alarm Status
1 = Codepad Display Extinguish After 60 Seconds
2 = Single Button Arming In Allowed (AWAY/STAY Mode 1 & 2)
4 = Single Button Disarming Allowed (STAY Mode 1 & 2)
8 = Alarm Memory Reset On Disarm
1 = Codepad Fault Alarm Beeps Allowed
2 = Use Digit 3 For Codepad Duress Instead Of Digit 9
4 = Alarms Activate Siren & Strobe Outputs In STAY Mode 1 & 2
8 = Reserved
1 = Radio Receiver (WE800)
2 = Latching Keyswitch Input
3 = Momentary Keyswitch Input
4 = Reserved
Location 748
Location 749
Location 901
Location 902
Location 903
Location 904
Location 905
Location 906
Location 907
Location 908
Location 909
Location 910
Increments Of 5 ms
Increments Of 80 ms
0 = Defaulting Enabled
15 = Defaulting Disabled
Hour Of The Day (Tens Digit)
Hour Of The Day (Units Digit)
Minute Of The Day (Tens Digit)
Minute Of The Day (Units Digit)
Day Of The Month (Tens Digit)
Day Of The Month (Units Digit)
Month Of The Year (Tens Digit)
Month Of The Year (Units Digit)
Year (Tens Digit)
Year (Units Digit)
291
Page 229
N
Page 230
.
Page 231
)
Page 232
.
Page 233
.
Page 234
-
Page 235
R
Page 236
.
Page 154
*( ,(
Page 47
.
Page 225
.( .( .( .(
Page 226
.( N( .( N( .( N(
Electronics Design and Manufacturing Pty Limited ISSUE140
Solution 844/862/880
Installation Manual
ISSUE140 Electronics Design and Manufacturing Pty Limited
(
!"#$%&"'()).(K<"6<1GG&'6(!477%0(
Solution 844/862/880
Installation Manual
Location 000 – 015
K<&G1<=(37#754"'7(E$G87<(@"<(L797&M7<(N
Location 016 – 031
!79"':1<=(37#754"'7(E$G87<(@"<(L797&M7<(N
Page 143
.( .( .( .( .( .( .( .( .( .( .( .( .( .( .( .(
Page 143
.( .( .( .( .( .( .( .( .( .( .( .( .( .( .( .(
Location 032
C1':041B7(3"'7(@"<((L797&M7<(N
Location 033
Location 034 – 039
Location 040 – 055
3<1'0G&00&"'(@"<G1%(@"<(L797&M7<(N(
!$809<&87<(/F(E$G87<(@"<(L797&M7<(N
1 = HI-LO Handshake (Contact ID)
2 = 1400 Hz (TX @ 1900 Hz)
3 = 2300 Hz (Low Speed Sescoa)
1 = Contact ID
2 = 4 + 2 Express
3 = FSK 300 Baud
4 = Domestic
K<&G1<=(37#754"'7(E$G87<(@"<(L797&M7<(-
4 = No Handshake Required
5 = Pager
Page 144
N(
Page 145
5 = Basic Pager
6 = Reserved
7 = Reserved
8 = Reserved
N
Page 145
.( .( .( .( .( .(
Page 145
.( .( .( .( .( .( .( .( .( .( .( .( .( .( .( .(
Location 056 – 071
!79"':1<=(37#754"'7(E$G87<(@"<(L797&M7<(-
Location 072
C1':041B7(3"'7(@"<(L797&M7<(-
Location 073
3<1'0G&00&"'(@"<G1%(@"<(L797&M7<(-(
Location 074 – 079
!$809<&87<(/F(E$G87<(@"<(L797&M7<(-
Page 146
.( .( .( .( .( .( .( .( .( .( .( .( .( .( .( .(
Page 148
1 = HI-LO Handshake (Contact ID)
2 = 1400 Hz (TX @ 1900 Hz)
3 = 2300 Hz (Low Speed Sescoa)
1 = Contact ID
2 = 4 + 2 Express
3 = FSK 300 Baud
4 = Domestic
4 = No Handshake Required
5 = Pager
5 = Basic Pager
6 = Reserved
7 = Reserved
8 = Reserved
N(
Page 148
N
Page 148
.( .( .( .( .( .(
Location 080
F&1##&'6(@"<G1%
(
Location 081 – 112
L707<M7:
1 = Australian DTMF (5 Digits/Second)
2 = Australian Decadic
3 = Alternate DTMF & Decadic (AUST)
Page 149
4 = International DTMF
5 = Reversed Decadic
6 = Alternate DTMF & Reversed Decadic
N(
Page 149
Location 113 –142
37#9"(T<G&'6(!7`$7'97(
Page 150
.( .( .( .( .( .( .( .( .( .( .( .( .( .( .( .( .( .( .( .( .( .( .( .( .( .( .( .( .( .(
Location 143 – 158
37#9"(F&01<G&'6(!7`$7'97
Page 151
.( .( .( .( .( .( .( .( .( .( .( .( .( .( .( .(
Location 159 – 174
?1##(V19B(37#754"'7(E$G87<
Location 175
L&'6(?"$'%
Location 176
37#754"'7(\&'7(@1$#%(>5%&"'0(
Page 151
.( .( .( .( .( .( .( .( .( .( .( .( .( .( .( .(
0 = Panel Will Not Answer
1 – 13 = No Of Rings Until Panel Answers
14 = Answering Machine Bypass 2
15 = Answering Machine Bypass 1
Page 152
)
Page 153
1 = Display FAULT Indicator When Telephone Line Fails
2 = Sound Alarm When System Is Armed
4 = Sound Alarm When System Is Disarmed
8 = Reserved
.
ISSUE140 Electronics Design and Manufacturing Pty Limited
Solution 880
Programming Sheets
(
Location 177
F&1##7<(>5%&"'0(N
Location 178
F&1##7<(>5%&"'0(-
Location 179
(
F&1##7<(>5%&"'0(Q
Location 180
T#1<G(\&'B(>5%&"'0(
1 = Dialler Reporting Functions Allowed
2 = Remote Arming Via The Telephone Allowed
4 = Answering Machine Bypass Only When Armed
8 = Use Bell 103 For FSK Format (Disabled = CCITT V21)
1 = Open/Close Reports Only If Previous Alarm
2 = Open/Close Reports For STAY Mode 1 and STAY Mode 2
4 = Delay Siren Until Transmission Complete
8 = Extend Time To Wait For Handshake From 30 Seconds To 55 Seconds
1 = Set DTMF Dialling Pulses To 1 Digit/Second
2 = Reserved
4 = Change Decadic Dialling To 60/40
8 = Reserved
1 = Upload/Download Allowed
2 = Call Back Phone Number Required For Upload/Download
4 = Exit Upload/Download Connection On Alarm
8 = External Modem Module (CC811) Required For Upload/Download
Location 181 – 184
/'0%1##7<(?":7
Location 185 – 264
Z07<(?":70
Z07<(?":7(Q
Z07<(?":7(,
(
Z07<(?":7(X(
(
Z07<(?":7(N-(
(
Z07<(?":7(NR(
( ( ( ( (
Location 195 - 199
NR( NR( NR( NR( -(
Location 210 - 214
NR( NR( NR( NR( -(
Location 225 - 229
NR( NR( NR( NR( -(
Location 240 - 244
NR( NR( NR( NR( -(
Location 255 - 259
NR( NR( NR( NR( -(
Z07<(?":7(N
Z07<(?":7(*
Z07<(?":7(S
(
Z07<(?":7(N.(
(
Z07<(?":7(NQ(
(
Z07<(?":7(N,(
.
Page 159
.
Page 129/160
.
Page 162
N( -( Q( *(
Page 163
Location 185 - 189
-( R( )( .( N.(
Location 200 - 204
NR( NR( NR( NR( -(
Location 215 - 219
NR( NR( NR( NR( -(
Location 230 - 234
NR( NR( NR( NR( -(
Location 245 - 249
NR( NR( NR( NR( -(
Location 260 - 264
NR( NR( NR( NR( -(
Z07<(?":7(-
Z07<(?":7(R
Z07<(?":7()
(
Z07<(?":7(NN(
(
Z07<(?":7(N*(
(
(
Location 190 - 194
NR( NR( NR( NR( -(
Location 205 - 209
NR( NR( NR( NR( -(
Location 220 - 224
.( NR( NR( NR( Q(
Location 235 - 239
NR( NR( NR( NR( -(
Location 250 - 254
NR( NR( NR( NR( -(
( ( ( ( (
295
Page 157
X
Page 158
NR(((( NR ....(((( ((((
Z07<(?":7( K<&"<&%=(
K<&"<&%=(
0
1
2
3
4
Arm/Disarm
Arm Only
F709<&5%&"'(
Arm/Disarm + Open/Close Report
Arm Only + Close Report
Arm/Disarm + Code To Isolate
K<&"<&%=(
6
8
10
12
14
Table 170: User Code Priority Levels
F709<&5%&"'(
Arm/Disarm + Code To Isolate + Open/Close
Report
Arm/Disarm + Master Code Functions
Arm/Disarm + Master Code Functions +
Open/Close Report
Arm/Disarm + Master Code Functions + Code To
Isolate
Arm/Disarm + Master Code Functions + Code To
Isolate + Open/Close Report
Electronics Design and Manufacturing Pty Limited ISSUE140
Solution 844/862/880
Installation Manual
Location 265
F1=(T#1<G(J"'70
1 = Zone 1
2 = Zone 2
4 = Zone 3
8 = Zone 4
Page 168
.(
Location 266
H>\(L70&0%"<(P1#$7
0 = No End Of Line Resistor
1 = 1K
2 = 1K5
3 = 2K2
4 = 3K3
5 = 3K9
6 = 4K7
7 = 5K6
8 = 6K8
9 = 10K
10 = 12K
11 = 22K
12 = Reserved
13 = Reserved
14 = Reserved
15 = Split EOL (3K3/6K8)
Eight Programmable Zones
Page 170
NR
Location 267 – 322
J"'70(
Page 174
J"'7(N(
Location 267 - 273
J"'7(-(
Location 274 - 280
( ( ( ( ( ( ( ( ( -( .( .( N( N*( N( N( ( ( N( .( .( N( N*( N( N(
J"'7(Q(
Location 281 - 287
J"'7(*(
Location 288 - 294
J"'7(R(
Location 295 – 301
N( .( .( N( N*( N( N( ( ( N( .( .( N( N*( N( N( ( ( .( .( .( N( N*( N( N(
J"'7(,(
Location 302 - 308
J"'7(S(
Location 309 - 315
J"'7()(
Location 316 - 322
.( .( .( N( N*( N( N( ( ( .( .( .( N( N*( N( N( ( ( X( .( .( N( N-( N( N(
( ( ( (
J"'7(
3=57(
J"'7(K$#07(
?"$'%(
J"'7(K$#07(
?"$'%(3&G7(
J"'7(
>5%&"'(N(
J"'7(
>5%&"'(-(
J"'7(3=570
There are fifteen different zone types to choose from. Each zone contains eight locations.
J"'7(3=57( F709<&5%&"'( J"'7(3=57(
L75"<%(
?":7(
F709<&5%&"'(
0
1
2
3
4
5
6
7
Instant
Handover
Delay-1
Delay-2
Reserved
Reserved
24 Hour Medical
24 Hour Panic
8
9
10
11
12
13
14
15
( ( (
F&1##7<(
>5%&"'0(
24 Hour Hold-Up
24 Hour Tamper
Reserved
Keyswitch
24 Hour Burglary
24 Hour Fire
Chime Only
Zone Not Used
Table 171: Available Zone Types
?"''79%&"'0(@"<(!5#&%(H>\(L70&0%"<0(@"<()(J"'7(>57<1%&"'(
Figure 23: Split EOL Wiring Diagram
ISSUE140 Electronics Design and Manufacturing Pty Limited
Solution 880
Programming Sheets
J"'7(K$#07(?"$'%(!7%%&'60
The pulse count settings for each zone can be programmed between 0 - 15.
J"'7(K$#07(?"$'%(3&G7
Zone pulse count time is the time frame or period over which the number of pulses must register.
-.(G0(\""5(L705"'07(3&G7(
J"'7(K$#07(?"$'%(3&G7(
NR.(G0(\""5(L705"'07(3&G7(
J"'7(K$#07(?"$'%(3&G7(
0
1
0.5 Second
1 Second
8
9
20 Seconds
30 Seconds
2
3
2 Seconds
3 Seconds
4 Seconds
10
11
40 Seconds
50 Seconds
60 Seconds
4
5
6
7
5 Seconds
10 Seconds
15 Seconds
12
13
14
15
90 Seconds
120 Seconds
200 Seconds
Table 172: Zone Pulse Count Time Options
J"'7(>5%&"'0(N(
>5%&"'(
1
2
4
8
(
F709<&5%&"'(
Lockout Siren/Lockout Dialler
Delay Alarm Reporting
Silent Alarm
Sensor Watch
Table 173: Zone Options 1
J"'7(F&1##7<(>5%&"'0
(
J"'7(>5%&"'0(-(
>5%&"'(
1
2
4
8
F709<&5%&"'(
Isolated In STAY Mode 1
Zone Isolation Allowed
Forced Arming Allowed
Enable Zone Restore Report
Table 174: Zone Options 2
>5%&"'(
0
1
2
4
8
F709<&5%&"'(
No Report Required
Receiver 1
Receiver 2
Receiver 1 + 2
Receiver 2 Only When Receiver 1 Fails
297
Table 175: Zone Dialler Options
J"'7(F709<&5%&"'0
Use this table as a reference to indicate what each zone is connected to.
J"'7( F709<&5%&"'( J"'7(
1 5
2 6
3
4
7
8
Table 176: Zone Descriptions
O&<&'6(F&16<1G(@"<(U7=0D&%94(J"'7(
F709<&5%&"'(
Figure 24: Wiring Diagram For Keyswitch Zone
Electronics Design and Manufacturing Pty Limited ISSUE140
Location 323
!D&'67<(!4$%:"D'(?"$'%(@"<(!&<7'(
Location 324
!D&'67<(!4$%:"D'(?"$'%(@"<(F&1##7<(
Location 325 – 326
J"'7(!%1%$0(Y(V=5100(L75"<%0(
Location 327 – 328
J"'7(!%1%$0(Y(3<"$8#7(L75"<%0
Location 329 – 330
J"'7(!%1%$0(Y(!7'0"<(O1%94(L75"<%0
Location 331
J"'7(!%1%$0(Y(T#1<G(L70%"<7(?":7(
Location 332
J"'7(!%1%$0(L75"<%&'6(>5%&"'0
Location 333 – 334
>57'+?#"07(L75"<%0
Location 335
>57'+?#"07(L75"<%&'6(>5%&"'0
Location 336
?":751:(F$<700(L75"<%
Location 337 – 338
?":751:(K1'&9(L75"<%
Location 339 – 340
?":751:(@&<7(L75"<%
Location 341 – 342
?":751:(27:&91#(L75"<%
Location 343
?":751:(L75"<%&'6(>5%&"'0
Location 325
Location 326
Location 327
Location 328
Location 329
Location 330
Solution 844/862/880
Installation Manual
Zone Bypass Report
Zone Bypass Restore Report
Zone Trouble Report
Zone Trouble Restore Report
Sensor Watch Report
Sensor Watch Restore Report
Page 185
Q
Page 186
,
Page 188
X( )(
Page 189
-( Q(
Page 190
*( R(
Page 190
N*(
Page 190
0 = No Report Required
1 = Receiver 1
2 = Receiver 2
4 = Receiver 1 + 2
8 = Receiver 2 Only When Receiver 1 Fails
Location 333
Location 334
Opening Report
Closing Report
N(
Page 191
NN( N-(
Page 191
0 = No Report Required
1 = Receiver 1
2 = Receiver 2
4 = Receiver 1 + 2
8 = Receiver 2 Only When Receiver 1 Fails
N(
Page 192
,(
Page 192
S( NR(
Page 193
S( N*(
Page 193
S( NQ(
Page 194
0 = No Report Required
1 = Receiver 1
2 = Receiver 2
4 = Receiver 1 + 2
8 = Receiver 2 Only When Receiver 1 Fails
N(
ISSUE140 Electronics Design and Manufacturing Pty Limited
Solution 880
Programming Sheets
Location 344 – 345
!=0%7G(!%1%$0(c(@$07(@1&#(L75"<%(
Location 346 – 347
!=0%7G(!%1%$0(c(@$07(@1&#(L70%"<7(L75"<%(
Location 348 – 349
!=0%7G(!%1%$0
(c
T?(@1&#(L75"<%
Location 350 – 351
!=0%7G(!%1%$0(Y(T?(@1&#(L70%"<7(L75"<%(
Location 352 – 353
!=0%7G(!%1%$0(Y(\"D(V1%%7<=(L75"<%
Location 354 – 355
!=0%7G(!%1%$0(Y(\"D(V1%%7<=(L70%"<7(L75"<%
Location 356 – 358
!=0%7G(!%1%$0(c(T99700(F7'&7:
Location 359
!=0%7G(!%1%$0(L75"<%&'6(>5%&"'0
Location 360 – 366
370%(L75"<%&'6(3&G7
Location 367
370%(L75"<%&'6(F&1##7<(>5%&"'0(
Location 356
Location 357
Location 358
Code Retries
Reporting Code – Tens Digit
Reporting Code – Units Digit
0 = No Report Required
1 = Receiver 1
2 = Receiver 2
4 = Receiver 1 + 2
8 = Receiver 2 Only When Receiver 1 Fails
Location 360
Location 361
Location 362
Location 363
Location 364
Location 365
Location 366
Actual Hour Of The Day (Tens Digit)
Actual Hour Of The Day (Units Digit)
Actual Minute Of The Day (Tens Digit)
Actual Minute Of The Day (Units Digit)
Test Report Code (Tens Digit)
Test Report Code (Units Digit)
Repeat Interval In Days
0 = No Report Required
1 = Receiver 1
2 = Receiver 2
4 = Receiver 1 + 2
8 = Receiver 2 Only When Receiver 1 Fails
Location 368 – 397
>$%5$%((
?"';&6$<1%&"'0
>$%5$%(N
L7#1=(
Location 368 - 373
N( N*( .( .( .( .(
>$%5$%(-
Location 374 - 379
-( S( N.( -( N( R(
Default For
Horn Speaker
Location 386 – 391
N( NR( N( .( .( .(
?":751:(
Default For
Fire Alarm Verification
Location 392 – 397
.( NQ( -( N( .( N(
Default For
Sirens Running
Default For Entry/Exit
Warning + Day Alarm
!%<"87
(
HM7'%(3=57( K"#1<&%=( 3&G7(V107( 3&G7(2$#%&5#&7<(
299
N(
Page 202
Location 380 - 385
-( .( ,( *( .( )(
Default For Strobe
(Reset In 8 Hrs)
( ( ( ( ( (
Page 194
N.( Q(
Page 194
N.( )(
Page 195
N.( -(
Page 195
N.( S(
Page 196
N.( N(
Page 197
N.( ,(
Page 197
,( S( N-(
Page 198
N(
Page 198
.( .( .( .( S( N( .(
Page 199
Electronics Design and Manufacturing Pty Limited ISSUE140
Location 398 – 399
H'%<=(3&G7<(N
Location 400 – 401
H'%<=(3&G7<(-
Location 402 – 403
HI&%(3&G7
Location 404 – 405
H'%<=(_$1<:(3&G7(@"<(!3T](2":7(
Location 406 – 407
F7#1=(T#1<G(L75"<%&'6(3&G7(
Location 408 – 409
!7'0"<(O1%94(3&G7
Location 410
?":751:(\"9B"$%(3&G7
Location 398
Location 399
Location 400
Location 401
Location 402
Location 403
Location 404
Location 405
Location 406
Location 407
Location 408
Location 409
Location 410
Location 411
!&<7'(L$'(3&G7
Location 413
T$%"(T<G&'6(K<7YT#7<%(3&G7(
Location 411
Location 412
!&<7'(!"$':(L1%7(a!#"D(mY!"$':Yn(@10%b
Location 413
Location 414 – 417
T$%"(T<G&'6(3&G7
Location 418 – 421
T$%"(F&01<G&'6(3&G7
Location 422
U&00Y>;;(O1&%(3&G7(
Location 423
L707<M7:
Location 414
Location 415
Location 416
Location 417
Location 418
Location 419
Location 420
Location 421
Location 422
Solution 844/862/880
Installation Manual
Increments Of 1 Second (0 - 15 Sec’s)
Increments Of 16 Seconds (0 - 240 Sec’s)
Increments Of 1 Second (0 - 15 Sec’s)
Increments Of 16 Seconds (0 - 240 Sec’s)
Increments Of 1 Second (0 - 15 Sec’s)
Increments Of 16 Seconds (0 - 240 Sec’s)
Increments Of 1 Second (0 - 15 Sec’s)
Increments Of 16 Seconds (0 - 240 Sec’s)
Increments Of 1 Second (0 - 15 Sec’s)
Increments Of 16 Seconds (0 - 240 Sec’s)
Increments Of Days (Tens Digit)
Increments Of Days (Units Digit)
Increments Of 10 Seconds
Increments Of 1 Minute (0 – 15 Min’s)
Increments Of 5 Minutes
Page 218
*( N(
Page 218
)( -(
Page 219
N-( Q(
Page 219
.( .(
Page 219
.( .(
Page 220
.( .(
Page 220
.
Page 221
R
Page 221
S
Page 222
N
Page 222
(
Hour Of The Day (Tens Digit)
Hour Of The Day (Units Digit)
Minute Of The Day (Tens Digit)
Minute Of The Day (Units Digit)
.( .( .( .(
Page 223
(
Hour Of The Day (Tens Digit)
Hour Of The Day (Units Digit)
Minute Of The Day (Tens Digit)
Minute Of The Day (Units Digit)
Increments Of 500 ms (500 ms – 8 Sec’s)
.( .( .( .(
Page 223
Q(
Page 223
.
ISSUE140 Electronics Design and Manufacturing Pty Limited
Solution 880
Programming Sheets
Location 424
!=0%7G(>5%&"'0(N
Location 425
!=0%7G(>5%&"'0(-(
Location 426
!=0%7G(>5%&"'0(Q
Location 427
!=0%7G(>5%&"'0(*
Location 428
?"'0$G7<(>5%&"'0(N
Location 429
?"'0$G7<(>5%&"'0(-
Location 430
?"'0$G7<(>5%&"'0(Q
Location 431
L1:&"(/'5$%(>5%&"'0
1 = Enable EDM Smart Lockout
2 = Enable Monitoring Of Horn Speaker
4 = Allow Strobe Indications For Radio Arm/Disarm
8 = Allow Horn Speaker Beeps For Radio Arm/Disarm
1 = Enable Codepad Panic To Be Silent
2 = Enable Codepad Fire To Be Silent
4 = Enable Codepad Medical To Be Silent
8 = Enable Access Denied To Be Silent
1 = AC Fail In 1 Hour (Disabled = After 2 Minutes)
2 = Ignore AC Mains Fail Indication
4 = Pulse Count Handover Allowed
8 = Handover Delay To Be Sequential
1 = Panel To Power Up Disarmed (If Power Reset)
2 = Arm/Disarm Tracking On Power Up
4 = Internal Crystal To Keep Time
8 = Keyswitch Interface, Night Arm Station Or RE005 Installed
1 = Test Reports Only When Armed
2 = Test Report After Siren Reset
4 = Auto Arm In STAY Mode 1
8 = STAY Indicator To Display Day Alarm Status
1 = Codepad Extinguish Mode
2 = Single Button Arming Allowed (AWAY, STAY Mode 1 & 2)
4 = Single Button Disarming Allowed (STAY Mode 1 & 2)
8 = Alarm Memory Reset On Disarm
1 = Codepad Fault Alarm Beeps Allowed
2 = Use Digit 3 For Codepad Duress Instead Of Digit 9
4 = Alarms Activate Siren & Strobe Outputs In STAY Mode 1 & 2
8 = Reserved
1 = Radio Receiver (WE800)
2 = Latching Keyswitch Input
3 = Momentary Keyswitch Input
4 = Reserved
301
Page 229
N
Page 230
.
Page 231
)
Page 232
.
Page 233
.
Page 234
-
Page 235
R
Page 236
.
Electronics Design and Manufacturing Pty Limited ISSUE140
Location 432
K1<%&%&"'&'6(>5%&"'0(N
Location 433
K1<%&%&"'&'6(>5%&"'0(-
Location 434 – 441
J"'7(T##"91%&"'0(@"<(T<71(N
Location 442 – 449
J"'7(T##"91%&"'0(@"<(T<71(-
Location 450 – 465
Z07<(?":7(T##"91%&"'0
Location 450
T<710(@"<(Z07<(kN
.
Location 454
T<710(@"<(Z07<(kR
.
Location 458
T<710(@"<(Z07<(kX(
.
Location 462
T<710(@"<(Z07<(kNQ(
.
Location 748 - 749
L&'6(V$<0%(?"$'%
Location 900
F&018#7(@19%"<=(F7;1$#%(
Location 901 – 904
!=0%7G(3&G7
Location 905 – 910
!=0%7G(F1%7(
Solution 844/862/880
Installation Manual
Page 243
1 = First To Open/Last To Close Reporting
2 = Area 1 Codepad Connected To Data Terminal
4 = Reset Sirens From Any Area Allowed
8 = Master Codepad To Display AUX Indicator When On-Line
.
1 = Lock Area 1 To Receiver 1 and Lock Area 2 To Receiver 2
2 = User Codes Allowed To Arm/Disarm Both areas At Same Time (code + 0 + #)
4 = Reserved
8 = Reserved
Page 244
.
Page 245
.( .( .( .( .( .( .( .(
Page 245
.( .( .( .( .( .( .( .(
Page 247
Location 451
T<710(@"<(Z07<(k-
.
Location 455
T<710(@"<(Z07<(k,
.
Location 459
T<710(@"<(Z07<(kN.(
.
Location 463
T<710(@"<(Z07<(kN*(
.
Location 452
T<710(@"<(Z07<(kQ
.
Location 456
T<710(@"<(Z07<(kS
.
Location 460
T<710(@"<(Z07<(kNN(
.
Location 464
T<710(@"<(Z07<(kNR(
.
Location 748
Location 749
0 = Defaulting Enabled
15 = Defaulting Disabled
Increments Of 5 ms
Increments Of 80 ms
Location 901
Location 902
Location 903
Location 904
Hour Of The Day (Tens Digit)
Hour Of The Day (Units Digit)
Minute Of The Day (Tens Digit)
Minute Of The Day (Units Digit)
Location 905
Location 906
Location 907
Location 908
Location 909
Location 910
Day Of The Month (Tens Digit)
Day Of The Month (Units Digit)
Month Of The Year (Tens Digit)
Month Of The Year (Units Digit)
Year (Tens Digit)
Year (Units Digit)
Location 453
T<710(@"<(Z07<(k*
.
Location 457
T<710(@"<(Z07<(k)
.
Location 461
T<710(@"<(Z07<(kN-(
.
Location 465
T<710(@"<(Z07<(kN,(
.
Page 154
*( ,(
Page 47
.
Page 225
.( .( .( .(
Page 226
.( N( .( N( .( N(
ISSUE140 Electronics Design and Manufacturing Pty Limited
/':7I(
Solution 844/862/880
Installation Manual
2
2 Channel Hand Held Transmitter Operations
Arming In AWAY Mode.......................................... 81
Arming In STAY Mode 1......................................... 81
Disarming From AWAY Mode ................................ 81
Disarming From STAY Mode 1 ............................... 81
Panic Alarm .............................................................. 81
2 Wire Smoke Detector Interface ............................... 255
24 Hour Zone.............................................................. 261
Single Button Operation..........................................234
Via Telephone .................................................124, 157
Audible Indicators.....................................52, 56, 59, 241
Auto Arm In STAY Mode 1 .......................................233
Auto Arming Pre-Alert Timer.....................................222
Auto Arming Time ......................................................222
Auto Disarming Time .................................................223
Automatic Stepping Of Locations.................................44
AUX Indicator.......................................................58, 240
AWAY Indicator.....................................................50, 53
AWAY Mode ..............................................................259
Arming ..............................................................62, 118
Disarming..................................................................63
AWAY or # .................................................................259
4
4 + 2 Reporting Format .............................................. 138
4 Channel Hand Held Transmitter Operations
Arming In AWAY Mode.......................................... 82
Arming In STAY Mode 1......................................... 82
Disarming From AWAY Mode ................................ 82
Disarming From STAY Mode 1 ............................... 82
Panic Alarm .............................................................. 82
Turning Remote Output 1 Off .................................. 83
Turning Remote Output 1 On ................................... 83
Turning Remote Output 2 Off .................................. 83
Turning Remote Output 2 On ................................... 83
A
AC Mains
Fail In 1 Hour ......................................................... 231
Ignore Fail Indication ............................................. 231
Report ..................................................................... 195
Restore Report ........................................................ 195
AC Mains Failure ......................................................... 76
Access Codes
Installer Code.......................................................... 162
User Code Priority Level ........................................ 165
User Codes.............................................................. 163
Access Denied
Code Retries ........................................................... 197
Access Denied To Be Silent ....................................... 230
Alarm Condition ......................................................... 259
Alarm Link ......................................................... 129, 160
Direct Connect ........................................................ 128
Enable Alarm Link Call Back......................... 129, 160
Enable Upload/Download............................... 129, 160
External Modem Module ........................................ 129
Initiate Modem Call ................................................ 121
Remote Connect ..................................................... 126
Remote Connect With Call Back Verification........ 127
Remote Connect With Customer Control ............... 126
Remote Connect Without Call Back Verification... 127
Terminate Session If Report Pending ............. 129, 160
Alarm Link Software .................................................. 253
Alarm Memory Reset On Disarm............................... 234
Alarm Reporting ......................................................... 179
Answering Machine Bypass ............................... 152, 259
Only When Armed.................................................. 157
Area Display Indicator.......................................... 58, 239
Area On/Off Indicator........................................... 57, 239
Armed ......................................................................... 259
Arming
Both Areas At Same Time ................................ 99, 117
In AWAY Mode ............................................... 62, 118
In STAY Mode 1 .............................................. 64, 118
In STAY Mode 2 .............................................. 67, 119
ISSUE140 Electronics Design and Manufacturing Pty Limited
B
Basic Pager..................................................................139
Basic Pager Reporting.................................................139
Battery Testing ............................................................259
Bell Test ......................................................................119
Bypass Reports............................................................188
C
Call Back Telephone Number .....................................151
Cellular Diallers ..........................................................254
Code Retries ................................................................197
Codepad ......................................................................259
Buzzer .....................................................................202
Buzzer Tone Change ...............................................122
Connections When Partitioning ..............................249
CP5 Eight Zone Area Addressable Codepad...........253
CP5 Master Partitioned ...........................................253
Determine Area .......................................................122
DIP Switches...........................................................248
Codepad Duress ....................................................69, 192
Codepad Duress Report...............................................192
Codepad Extinguish Mode ..........................................234
Codepad Fire .................................................69, 193, 230
Codepad Fire Report ...................................................193
Codepad Fire To Be Silent ..........................................230
Codepad Indicators
Area Display .....................................................58, 239
Area On/Off ......................................................57, 239
Audible..................................................52, 56, 59, 241
AUX ..................................................................58, 240
AWAY ................................................................50, 53
FAULT..................................................51, 55, 59, 240
MAINS..................................................51, 54, 59, 240
OFF Indicator/Zone Sealed .......................................55
ON Indicator/Zone In Alarm.....................................55
PARTIAL..........................................................58, 239
Programming Mode ..................................................55
STAY ..................................................................51, 54
System Disarmed ......................................................54
Zone ......................................................50, 53, 57, 238
Zone Isolating Mode .................................................54
Codepad Lockout Time...............................................220
Codepad Medical ..........................................69, 193, 230
Codepad Medical Report.............................................193
Codepad Medical To Be Silent ...................................230
Codepad Panic...............................................69, 192, 230
Codepad Panic Report.................................................192
Codepad Panic To Be Silent........................................230
Index
Codepad Reporting Options ........................................194
Codepads
CP5 Eight Zone LCD Codepad .................................53
CP5 Eight Zone LED Codepad .................................50
CP5 Master Partitioned Codepad ............................238
Command 958 - Enable/Disable Zone Status................36
Command 959 - Test Programming Key ......................37
Command 960 - Exit Installer's Programming Mode....39
Command 961 - Reset Control Panel Back To Factory
Default.......................................................................39
Command 962 - Copy Control Panel Memory To
Programming Key .....................................................40
Command 963 - Copy From Programming Key To
Control Panel.............................................................41
Command 964 - Erase Programming Key ....................42
Command 965 - Set Up Domestic Dialling...................43
Command 966 - Enable/Disable Automatic Stepping...44
Command 999 - Display Panel Type/Software Version46
Communication Failure.................................................75
Component Overlay ....................................................263
Connections Of Split EOL Using N/O Contacts .........172
Consumer Options 1............................................233, 234
Auto Arm In STAY Mode 1 ...................................233
Enable STAY Indicator To Display Day Alarm Status
............................................................................233
Send Test Report After Siren Reset ........................233
Send Test Reports Only If Armed...........................233
Consumer Options 2
Alarm Memory Reset On Disarm ...........................234
Enable Codepad Extinguish Mode ..........................234
Single Button Arming .............................................234
Single Button Disarming.........................................234
Consumer Options 3
Codepad Fault Alarm Beeps ...................................235
Operation Of Siren & Strobe In STAY Mode.........235
Use Digit 3 For Duress Instead Of Digit 9 ..............235
Contact ID Format ......................................................136
Control Panel To Power Up Disarmed........................232
Copy Control Panel Memory To Programming Key ....40
Copy From Programming Key To Control Panel .........41
D
Date and Time ...............................................74, 114, 225
Day Alarm...........................................................168, 259
Latching ..................................................................168
Operation.................................................................169
Resetting .................................................................168
Status Indicator .......................................................233
Turning On/Off .......................................................120
Decadic Dialling To 60/40 ..........................................159
Defaulting The Control Panel .................................39, 48
Delay Alarm Reporting Time......................................219
Delay Siren Until Transmission Complete..................158
Detectors .....................................................................259
Dialler .........................................................................259
Dialler Information
Answering Machine Bypass....................................152
Call Back Telephone Number .................................151
Dialling Format .......................................................149
Handshake Tone For Receiver 1 .............................144
Handshake Tone For Receiver 2 .............................147
Primary Telephone Number For Receiver 1 ...........143
Primary Telephone Number For Receiver 2 ...........146
Programing Telephone Numbers ............................142
Electronics Design and Manufacturing Pty Limited
305
Ring Count ............................................................. 152
Secondary Telephone Number For Receiver 1 ....... 143
Secondary Telephone Number For Receiver 2 ....... 146
Subscriber ID Number For Receiver 1 ................... 145
Subscriber ID Number For Receiver 2 ................... 148
Telco Arming Sequence ......................................... 150
Telco Disarming Sequence ..................................... 151
Telephone Line Fault Options ................................ 153
Transmission Format For Receiver 1 ..................... 145
Transmission Format For Receiver 2 ..................... 148
Dialler Options 1
Allow Dialler Reporting Functions ........................ 157
Answering Machine Bypass Only When Armed... 157
Disable Dialler Reporting Functions ...................... 157
Remote Arming Via Telephone.............................. 157
Dialler Options 2
Delay Siren Until Transmission Complete ............. 158
Extend Time To Wait For Handshake .................... 158
Open/Close Reports In STAY Mode ...................... 158
Open/Close Reports Only If Previous Alarm Has
Occurred ............................................................. 158
Dialler Options 3
Change Decadic Dialling To 60/40 ........................ 159
Set DTMF Dialling Pulses To 1 Digit/Second ....... 159
Dialler Reporting Formats .......................................... 136
Dialling Format .......................................................... 149
Disable Factory Default................................................ 47
Disarmed .................................................................... 259
Disarming
Automatic ............................................................... 223
Both Areas At Same Time................................ 99, 117
From AWAY Mode.................................................. 63
From STAY Mode 1................................................. 66
From STAY Mode 2................................................. 68
Single Button Operation ......................................... 234
Domestic Dialling
Acknowledging Alarm Report................................ 132
Changing Domestic Telephone Numbers ......... 88, 104
Command 965 .......................................................... 43
Disable89, 91, 92, 93, 94, 96, 105, 107, 108, 109, 110,
112, 134
Format .................................................................... 132
Function.................................................................. 132
Setting Up & Programming .................................... 133
DTMF Dialling Pulses To 1 Digit/Sec ....................... 159
Dual Reporting ........................................................... 259
Duress Alarm................................................................ 69
E
E2 Fault ........................................................................ 74
EDM Smart Watch ..................................................... 229
EDMSAT.............................................. 96, 204, 253, 259
Entry Guard Timer For STAY Mode ............. 64, 67, 219
Entry Time.................................................................. 259
Entry Timer 1 ............................................................. 218
Entry Timer 2 ............................................................. 218
Entry Warning ............................................................ 259
EOL Resistor Value.................................................... 170
Erase Programming Key............................................... 42
Event Memory Recall Mode................................. 98, 116
Exit Installer's Programming Mode .............................. 39
Exit Time ............................................................ 219, 260
External Equipment .................................................... 260
ISSUE140
F
Fault
AC Mains Failure ..................................................... 76
Beeps ...................................................................... 235
Communication Failure ............................................ 75
Date and Time .......................................................... 74
E2 Fault .................................................................... 74
Fuse Fail ................................................................... 75
Horn Speaker ............................................................ 74
Low Battery .............................................................. 74
Sensor Watch ............................................................ 74
Telephone Line Fault ................................................ 74
Fault Analysis Mode..................................................... 73
Determine Type ...................................................... 120
Exit ......................................................................... 120
FAULT Indicator...................................... 51, 55, 59, 240
Features
Solution 404.............................................................. 19
Solution 406.............................................................. 20
Solution 408.............................................................. 21
Fire Alarm .................................................................... 69
Forced Arming.................................. 62, 65, 67, 183, 260
Fuse Fail ....................................................................... 75
G
Glossary Of Terms...................................................... 259
H
Hand Held Dialler Tester............................................ 254
Hand Held Programmer ........................................ 31, 253
Hand Held Radio Remote Control.............................. 260
Hand Held Transmitters.............................................. 252
Handover .................................................................... 175
Delay....................................................................... 260
Delay To Be Sequential .......................................... 231
Handshake
Extend Time To Wait ............................................. 158
Handshake Tone For Receiver 1................................. 144
Handshake Tone For Receiver 2................................. 147
Hold Down Function
Arm In AWAY Mode ............................................. 118
Arm In STAY Mode 1 ............................................ 118
Arm In STAY Mode 2 ............................................ 119
Bell Test.................................................................. 119
Codepad Buzzer Tone Change ............................... 122
Fault Analysis Mode............................................... 120
Horn Speaker Test .................................................. 119
Initiate Modem Call ................................................ 121
Reset Latching Outputs........................................... 121
Send Test Report .................................................... 122
Strobe Test.............................................................. 119
Turning Day Alarm On/Off .................................... 120
Horn Speaker ................................................................ 74
Monitor ................................................................... 229
Test ......................................................................... 119
I
Installer Code.............................................................. 162
Installer Code Function
Change Telco Arm/Disarm Sequence............... 90, 106
Changing Domestic Phone Numbers ........................ 88
Event Memory Recall ............................................... 98
Satellite Siren Service Mode..................................... 96
ISSUE140 Electronics Design and Manufacturing Pty Limited
Solution 844/862/880
Installation Manual
Set First Test Report..................................................87
Setting STAY Mode 2 Zones ............................95, 111
Telephone Monitor Mode..........................................97
Walk Test Mode........................................................97
Installer's Programming Commands
958 - Enable/Disable Zone Status .............................36
959 - Test Programming Key ....................................37
960 - Exit Installer's Programming Mode .................39
961 - Reset Control Panel Back To Factory Default .39
962 - Copy Panel Memory To Programming Key ....40
963 - Copy From Programming Key To Panel .........41
964 - Erase Programming Key ..................................42
965 - Set Up Domestic Dialling ................................43
966 - Automatic Stepping Of Locations....................44
999 - Display Panel Type/Software Version Number
...............................................................................46
Internal Crystal To Keep Time....................................232
Introduction ...................................................................18
Invalid Code ................................................197, 220, 230
Isolate In STAY Mode 1 .............................................183
Isolating Allowed ........................................................183
Isolating Zones ..............................................................70
Code To Isolate .........................................................72
Standard Method .......................................................71
K
Keyswitch Zone ..........................................................176
Options ....................................................................181
L
Latching Outputs
Resetting..................................................................121
Lockout Dialler ...................................................179, 260
Lockout Siren ......................................................179, 260
Low Battery...................................................................74
Report......................................................................196
Restore Report.........................................................196
M
MAINS Indicator ......................................51, 54, 59, 240
Master Code ................................................................260
Master Code Function
Arm/Disarm Both Areas At Same Time ...................99
Changing & Deleting Remote Radio Codes............102
Changing & Deleting User Codes ...........................100
Changing Domestic Telephone Numbers................104
Event Memory Recall .............................................116
Setting Date and Time.............................................114
Turning Outputs ON/OFF .......................................112
Walk Test Mode......................................................115
Master Partitioned Codepad
Area Display Indicators.....................................58, 239
Area On/Off Indicators .....................................57, 239
Audible Indicators .............................................59, 241
AUX Indicator...................................................58, 240
FAULT Indicator ..............................................59, 240
MAINS Indicator ..............................................59, 240
PARTIAL Indicator ..........................................58, 239
Zone Indicators..................................................57, 238
Medical Alarm ..............................................................69
Modem Call.................................................................121
Modem Module...........................................................129
Monitoring Station ......................................................260
Index
N
New Zealand Telepermit Notes...................................272
Night Arm Station ...............................................232, 254
O
OFF Indicator/Zone Sealed ...........................................55
ON Indicator/Zone In Alarm.........................................55
Open/Close Reports ....................................................191
In STAY Mode........................................................158
Only If Previous Alarm Has Occurred ....................158
Reporting Options ...................................................191
Operating Remote Outputs Via Transmitter .................83
Option Bits ....................................................................34
Optional Equipment
2 Channel Radio Interface.......................................252
2 Wire Smoke Detector Interface............................255
304 Mhz RF Receiver .............................................252
Alarm Link Software...............................................253
Cellular Diallers ......................................................254
CP5 Eight Zone Area Addressable..........................253
CP5 Eight Zone LCD Codepad ...............................253
CP5 Eight Zone LED Codepad ...............................253
CP5 Master Partitioned Codepad ............................253
EDMSAT - Satellite Siren ......................................253
Hand Held Dialler Tester ........................................254
Hand Held Programmer ..........................................253
Hand Held Transmitters - 304 Mhz.........................252
Night Arm Station ...................................................254
Phone Controller .....................................................254
Programming Key ...................................................253
PS100 Power Supply Module .................................254
Radio Key/Keyswitch Interface ..............................255
Solution Codepad Mimic Board..............................254
TF008 Plug Pack .....................................................254
Output 1 ......................................................................202
Output 2 ......................................................................202
Output Event Type ......................................................204
AC Fail....................................................................206
AC Mains 60 Hz or 50 Hz.......................................210
Alarm When In AWAY Mode ................................208
Alarm When In STAY Mode ..................................207
Any Areas Armed ...................................................211
Any Areas Disarmed ...............................................211
Area 1 Codepad Data Terminal...............................212
Area 1 Has Zone Unsealed......................................211
Area 1 In Alarm ......................................................211
Area 1 Is Armed ......................................................211
Area 1 Is Disarmed..................................................211
Area 2 Codepad Data Terminal...............................212
Area 2 Has Zone Unsealed......................................211
Area 2 In Alarm ......................................................211
Area 2 Is Armed ......................................................211
Area 2 Is Disarmed..................................................211
Armed In AWAY Mode..........................................204
Armed In STAY Mode............................................204
Auto Arm Pre-Alert Time .......................................204
Codepad Duress Alarm ...........................................207
Codepad Fire Alarm................................................207
Codepad Medical Alarm .........................................206
Codepad Panic Alarm .............................................207
Codepad Tamper .....................................................207
Communications Failure .........................................209
307
Communications Failure After 3 Unsuccessful Calls
............................................................................ 209
Day Alarm Enabled ................................................ 206
Day Alarm Latching ............................................... 205
Day Alarm Resetting .............................................. 205
Dialler Active ......................................................... 209
Dialler Disabled...................................................... 209
EDMSAT - Satellite Siren ...................................... 204
Entry Warning ........................................................ 205
Entry Warning + Day Alarm Resetting .................. 205
Exit Warning .......................................................... 204
Exit Warning + Entry Warning .............................. 205
Exit Warning Finished............................................ 205
Exit Warning With All Zones Sealed Or Entry
Warning .............................................................. 204
Fire Alarm Latching ............................................... 208
Fire Alarm Resetting .............................................. 208
Fire Alarm Verification .......................................... 208
Fuse Fail ................................................................. 206
Global Chime.......................................................... 210
Horn Speaker .......................................................... 207
Horn Speaker Monitor Fail..................................... 206
Kiss-Off After Exit Time........................................ 205
Kiss-Off Received .................................................. 206
Low Battery ............................................................ 206
Mimic System Fault ............................................... 208
Mimic Zone 1 ......................................................... 210
Mimic Zone 2 ......................................................... 210
Mimic Zone 3 ......................................................... 210
Mimic Zone 4 ......................................................... 210
Mimic Zone 5 ......................................................... 210
Mimic Zone 6 ......................................................... 210
Mimic Zone 7 ......................................................... 210
Mimic Zone 8 ......................................................... 210
Radio Control Output 1 .......................................... 209
Radio Control Output 1 - Not In AWAY Mode ..... 209
Radio Control Output 2 .......................................... 209
Radio Control Output 2 - Not In AWAY Mode ..... 209
Remote Control 1 ................................................... 209
Remote Control 2 ................................................... 209
Remote Control 3 ................................................... 209
Ring Detect ............................................................. 209
Sensor Watch Alarm............................................... 206
Silent Alarm............................................................ 207
Sirens Running ....................................................... 207
Strobe Operating..................................................... 207
System Armed ........................................................ 204
System Disarmed.................................................... 204
Telephone Line Fail................................................ 206
Zone Not Sealed ..................................................... 210
Zone Not Sealed After Exit Time ........................... 210
Output Polarity
Normally Low, Going Open ................................... 214
Normally Low, Latching Open............................... 214
Normally Low, One Shot Open .............................. 214
Normally Low, One Shot Open With Alarm .......... 214
Normally Low, One Shot Open With Reset ........... 214
Normally Low, One Shot Open With Retrigger ..... 214
Normally Low, Pulsing Open ................................. 214
Normally Open, Going Low ................................... 213
Normally Open, Latching Low............................... 214
Normally Open, One Shot Low .............................. 213
Normally Open, One Shot Low With Alarm .......... 214
Normally Open, One Shot Low With Reset ........... 213
Electronics Design and Manufacturing Pty Limited ISSUE140
Normally Open, One Shot Low With Retrigger ..... 213
Normally Open, Pulsing Low ................................. 213
Output Not Used ..................................................... 213
Outputs ....................................................................... 202
One Shot Polarities ................................................. 216
Polarity ................................................................... 213
Pulsing Polarities .................................................... 215
Redirecting Output To Codepad Buzzer................. 203
Timing .................................................................... 215
Turning On/Off....................................................... 112
P
Panic ........................................................................... 260
Panic Alarm .................................................................. 69
PARTIAL Indicator .............................................. 58, 239
Partitioning
Area Addressable Codepad Operations .................. 242
Codepad Connections ............................................. 249
Codepad Operations................................................ 242
Master Partitioned Codepad Operations ................. 242
Master Partitioned LED Codepad........................... 238
Programming .......................................................... 243
Setting Up Area 1 Codepad .................................... 248
Setting Up Area 2 Codepad .................................... 248
Setting Up Master Partitioned Codepad ................. 248
User Code Allocations ............................................ 247
Zone Allocations..................................................... 245
Partitioning Options 1
Display AUX Indicator When Using Telephone Line
............................................................................ 244
First To Open/Last To Close Reporting.................. 243
Main Codepad To Display Data Only For Area 1 .. 243
Resetting Of Sirens From Either Area .................... 244
Partitioning Options 2
Enable "User Code + 0 + AWAY" To Arm/Disarm
Both Areas .......................................................... 244
Lock Area 1 To Receiver 1 & Lock Area 2 To
Receiver 2 ........................................................... 244
Phone Controller................................................. 254, 260
Plug Pack .................................................................... 254
Point ID Codes............................................................ 137
Power Up Disarmed.................................................... 232
Primary Telephone Number For Receiver 1 ............... 143
Primary Telephone Number For Receiver 2 ............... 146
Programming ................................................................ 28
Automatic Stepping Of Locations ............................ 44
Codepad Indicators ................................................... 29
Entry/Exit Tiemrs ................................................... 218
Installer's Programming Commands ......................... 35
Option Bits................................................ 34, 156, 228
Telephone Numbers................................................ 142
Via Hand Held Programmer ..................................... 31
Via Programming Key .............................................. 33
Via Remote Codepad ................................................ 29
Programming Key................................................. 33, 253
Copy From Programming Key To Panel .................. 41
Copy Panel Memory To Programming Key ............. 40
Erase ......................................................................... 42
Test ........................................................................... 37
Programming Sheets
Solution 404............................................................ 273
Solution 406............................................................ 283
Solution 408............................................................ 293
PS100 Power Supply Module ..................................... 254
ISSUE140 Electronics Design and Manufacturing Pty Limited
Solution 844/862/880
Installation Manual
Q
Quick Start ....................................................................22
R
Radio Input Options ....................................................236
Latching Keyswitch Input .......................................236
Momentary Keyswitch Input...................................236
Radio Receiver ........................................................236
Radio Key/Keyswitch Interface ..........................232, 255
Receiver 1
Handshake Tone......................................................144
Primary Telephone Number ....................................143
Secondary Telephone Number ................................143
Subscriber ID Number ............................................145
Transmission Format...............................................145
Receiver 2
Handshake Tone......................................................147
Primary Telephone Number ....................................146
Secondary Telephone Number ................................146
Subscriber ID Number ............................................148
Transmission Format...............................................148
Relay Output ...............................................................202
Remote Arming Via Telephone ..........................124, 157
Remote Operation Of Outputs Via Transmitter ............83
Remote Radio Transmitter Operations..........................78
Add or Changing Transmitter Codes.................79, 102
Arming In AWAY Mode ....................................81, 82
Arming In STAY Mode 1 ...................................81, 82
Deleting Transmitter Codes ..............................80, 103
Disarming From STAY Mode 1..........................81, 82
Disarming In AWAY Mode ................................81, 82
Horn Speaker Beeps ..................................................78
Operating Outputs .....................................................83
Panic Alarm.........................................................81, 82
Strobe Indications......................................................78
Remote Radio User Codes
Adding Or Changing .........................................79, 102
Deleting .............................................................80, 103
Reporting Format
4 + 2 Reporting Format ...........................................138
Basic Pager..............................................................139
Contact ID Format...................................................136
Domestic Dialling ...................................................132
Reset Control Panel Back To Factory Default ..............39
Ring Burst Time..........................................................154
Ring Count ..................................................................152
S
Satellite Siren ......................................................253, 259
Satellite Siren Service Mode .........................................96
Sealed ..........................................................................260
Secondary Telephone Number For Receiver 1 ...........143
Secondary Telephone Number For Receiver 2 ...........146
Sensor Watch ................................................74, 180, 260
Reports ....................................................................190
Time ........................................................................220
Silent Alarm ........................................................180, 260
Siren & Strobe In STAY Mode...................................235
Siren Run Time ...........................................................221
Siren Sound Rate.........................................................221
Smart Watch................................................................229
Software Version Number...........................................271
Solution Codepad Mimic Board..................................254
Index
Specifications ....................................................269, 271
STAY Indicator.......................................................51, 54
STAY Indicator To Display Day Alarm Status...........233
STAY Mode 1.............................................................261
Arming ..............................................................64, 118
Disarming..................................................................66
STAY Mode 2.............................................................261
Arming ..............................................................67, 119
Disarming..................................................................68
Setting Zones.....................................................95, 111
Strobe Output ..............................................................202
Strobe Test ..................................................................119
Subscriber ID Number For Receiver 1........................145
Subscriber ID Number For Receiver 2........................148
Swinger Shutdown Count
For Dialler ...............................................................186
For Siren..................................................................185
System Date ................................................................225
System Disarmed Indicator ...........................................54
System Operations ........................................................62
Arming In AWAY Mode ..........................................62
Arming In STAY Mode 1 .........................................64
Arming In STAY Mode 2 .........................................67
Disarming From AWAY Mode.................................63
Disarming From STAY Mode 1................................66
Disarming From STAY Mode 2................................68
System Options 1 ........................................................229
EDM Smart Lockout ...............................................229
Monitoring Of Horn Speaker ..................................229
System Options 2 ........................................................230
Access Denied To Be Silent....................................230
Codepad Fire To Be Silent ......................................230
Codepad Medical To Be Silent ...............................230
Codepad Panic To Be Silent....................................230
System Options 3 ........................................................231
AC Fail In 1 Hour ...................................................231
Handover Delay To Be Sequential..........................231
Ignore AC Mains Fail Indication ............................231
Zone Pulse Count Handover ...................................231
System Options 4 ........................................................232
Arm/Disarm Tracking On Power Up ......................232
Enable Control Panel To Power Up Disarmed........232
Enable Radio Key/Keyswitch Interface or Night Arm
Station .................................................................232
Internal Crystal To Keep Time................................232
System Status
AC Mains Fail Report .............................................195
AC Mains Fail Restore Report ................................195
Access Denied.........................................................197
Fuse Fail Report ......................................................194
Fuse Fail Restore Report .........................................194
Low Battery Report.................................................196
Low Battery Restore Report....................................196
Reporting Options ...................................................198
System Time ...............................................................224
T
Telco Arming Sequence ................................90, 106, 150
Telco Disarming Sequence .........................................151
Telecom Connection Diagrams...................................264
Telephone Anti-Jamming............................................266
Telephone Arming ..............................................124, 157
Telephone Line Fault ....................................................74
Telephone Line Fault Options.....................................153
309
Telephone Monitor Mode............................................. 97
Telephone Numbers
Changing Domestic Phone Numbers........................ 88
Terminal Definitions and Descriptions....................... 258
Test Reports................................................................ 122
After Siren Reset .................................................... 233
Dialler Options ....................................................... 199
Only When Armed ......................................... 233, 267
Repeat Interval........................................................ 199
Reporting Time....................................................... 199
Set First Test Report ................................................. 87
TF008 Plug Pack ........................................................ 254
Transmission Format For Receiver 1 ......................... 145
Transmission Format For Receiver 2 ......................... 148
Trouble Reports .......................................................... 189
U
Unsealed ..................................................................... 261
User Code Function
Arm/Disarm Both Areas At Same Time................. 117
User Codes ......................................................... 163, 261
Adding Or Changing ...................................... 100, 102
Allocations When Partitioning ............................... 247
Deleting .......................................................... 101, 103
Priority Level.......................................................... 165
W
Walk Test Mode ................................................... 97, 115
Warranty Statement .................................................... 270
Wiring Diagram.......................................................... 262
Z
Zone
Allocations.............................................................. 245
Defaults ............................................................ 24, 174
Dialler Options ............................................... 173, 184
EOL Resistor Value................................................ 170
Indicators .............................................. 50, 53, 57, 238
Isolating - Code To Isolate ....................................... 72
Isolating - Standard................................................... 71
Isolating Allowed ................................................... 183
Operating Information ............................................ 173
Options 1 ........................................................ 173, 179
Options 2 ................................................................ 173
Programming .......................................................... 173
Pulse Count..................................................... 173, 177
Pulse Count Handover .................................... 177, 231
Pulse Count Time ........................................... 173, 178
Report Code............................................................ 173
Reporting Information .................................... 173, 184
Restore Code .......................................................... 190
Restore Report ........................................................ 183
Status Mode .............................................................. 36
Trouble ................................................................... 189
Types ........................................................ 25, 173, 175
Zone Bypass ............................................................... 188
Zone Options 1
Delay Alarm Reporting .......................................... 179
Lockout Siren & Dialler ......................................... 179
Sensor Watch.......................................................... 180
Silent Alarm............................................................ 180
Zone Options 2
Forced Arming........................................................ 183
Isolate In STAY Mode 1 ........................................ 183
Electronics Design and Manufacturing Pty Limited ISSUE140
Zone Isolation Allowed .......................................... 183
Zone Restore Report ............................................... 183
Zone Reporting Information
Dialler Options ....................................................... 184
Zone Report Code................................................... 184
Zone Restore Code ................................................. 190
Zone Status
Bypass Reports ....................................................... 188
Reporting Options................................................... 190
Sensor Watch Reports............................................. 190
Trouble Reports ...................................................... 189
Zone Types
24 Hour Burglary Zone........................................... 176
Solution 844/862/880
Installation Manual
24 Hour Fire Zone ...................................................176
24 Hour Hold-Up Zone ...........................................176
24 Hour Medical .....................................................176
24 Hour Panic Zone ................................................176
24 Hour Tamper ......................................................176
Chime Zone.............................................................177
Delay-1 Zone...........................................................175
Delay-2 Zone...........................................................175
Handover Zone........................................................175
Instant Zone.............................................................175
Keyswitch Zone ......................................................176
Zone Not Used ........................................................177
Zones...........................................................................261
ISSUE140 Electronics Design and Manufacturing Pty Limited
Index 311
Electronics Design and Manufacturing Pty Limited ISSUE140
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Related manuals
advertisement
Table of contents
- 306 Introduction
- 307 Solution 844 Features
- 308 Solution 862 Features
- 309 Solution 880 Features
- 310 Quick Start
- 312 Solution 844 Zone Defaults
- 312 Solution 862 Zone Defaults
- 312 Solution 880 Zone Defaults
- 308 Programming