TOYOTOMI FS 1060A split-system air conditioner Service Manual
Below you will find brief information for split-system air conditioner FS 1060A. This document is a service manual for the FS 1060A split-system air conditioner. It covers maintenance and troubleshooting procedures, as well as assembly and disassembly instructions. The document also includes parts lists and wiring diagrams. The FS 1060A is suitable for various applications such as home, office or commercial buildings.
advertisement
Assistant Bot
Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.
▼
Scroll to page 2
of
28
Service Manual MODEL: FS1060A 1 Introduction and Features Model FS 1060A Remarks 2 Specification and Technical Parameter Model Function Rated Voltage Rated Frequency Total Capacity (Btu/h) Power Input (W) Rated Input (W) Rated Current (A) Air Flow Volume (m 3/h) (H/M/L)** Dehumidifying Volume (l/h) EER / C.O.P (W/W) Energy Class Model of Indoor Unit Fan Motor Speed (r/min) (H/M/L) Output of Fan Motor (w) Input of Heater (w) Fan Motor Capacitor (uF) Fan Motor RLA(A) Fan Type-Piece Diameter-Length (mm) Evaporator Pipe Diameter (mm) Indoor unit Row-Fin Gap(mm) Coil length (l) x height (H) x coil width (L) Swing Motor Model Output of Swing Motor (W) Fuse (A) Sound Pressure Level dB (A) (H/M/L) Sound Power Level dB (A) (H/M/L)*** Dimension (H/W/D) ( mm) Dimension of Package (L/W/H) ( mm) Net Weight /Gross Weight (kg) FS 1060A COOLING HEATING 380-415V 3N̚ 50Hz 16000W 6400W 7800W 12.05A 18000W 6200(9700)W 7800(11300)W 12.05(17.25) A 2000 5.2 2.5 / FS 1060Ai 550/500/450 r/min 130W 3500W 6uf 1.59A Centrifugal fan – 1 ij369X 180.5 Aluminum fin-copper tube ĭ7 3-1.4 914.4X471X42.2 SM016 4W PCB 5.0A 58/53/50 / 540/1750/380 2000/720/515 60/85 Model of Outdoor Unit Compressor Manufacturer/trademark Compressor Model Compressor Type L.R.A. (A) Compressor RLA(A) Compressor Power Input(W) Overload Protector Throttling Method Starting Method Working Temp Range (ć) Condenser Pipe Diameter (mm) Rows-Fin Gap(mm) Coil length (l) x height (H) x coil width (L) Fan Motor Speed (rpm) Output of Fan Motor (W) Outdoor Fan Motor RLA(A) unit Fan Motor Capacitor (uF) Air Flow Volume of Outdoor Unit Fan Type-Piece Fan Diameter (mm) Defrosting Method Climate Type Isolation Moisture Protection Permissible Excessive Operating Pressure for the Discharge Side(MPa) Permissible Excessive Operating Pressure for the Suction Side(MPa) Sound Pressure Level dB (A) (H/M/L) Sound Power Level dB (A) (H/M/L) Dimension (W/H/D) ( mm) Dimension of Package (L/W/H)( mm) Net Weight /Gross Weight (kg) Refrigerant Charge (kg) Length (m) Gas additional charge(g/m) Connec Liquid Pipe (mm) tion Outer Diameter Gas Pipe (mm) Pipe Height (m) Max Distance Length (m) FS 1060Ao Dallian SANYO / SANYO C-SBN453H8D SCrOll 67A 9.77A 5750W UP18 Capillary Capacitor -7 ćİTİ45ć Aluminum fin-copper tube ĭ9.52 3-1.8 745X1219.2X66 940 rpm 92W 0.42 4uf 5000 m3/h Axial fan -1 ĭ450X156 Auto defrost T1 I IP24 3.9 2.21 61 / 950X1250X412 450X1110X1280 115/126 R410A/5.0Kg 5M 100g//m ĭ12(1/2") ĭ19(3/4") 30 30 If the above specification's parameter has been changed, please refer to the nameplate. 3 Parts' Name air outlet display screen air discharge panel remote controller swing display screen timer air intake panel air intake temperature fan speed mode sealing tape ON/OFF air intake connecting pipe drain pipe air discharge 4 Outline and Installation Dimension Indoor unit's outline and installation size unit: rear Pipe side should be at least 30cm. front Pipe side should be at least 30cm. Outdoor unit's outline and installation size unit: more than more than 600 more than 600 more than 600 bolt nut 5 If above electric circuit diagram has been changed, please refer to it on the body. 6 Controller's function manual and operation method 1 Temperature Parameters Indoor preset temperature (Tpreset) Indoor ambient temperature (Tamb.) 2 Basic Functions Once the unit is started under any modes, the compressor will keep running within 6 minutes. Once the unit's stopped, it cannot be restarted until after 3-minute lag. (1) Cooling Mode Cooling Conditions and Process When Tamb.Tpreset+1ć , the unit will run under cooling mode, in which case the compressor and outdoor fan will EHstarted, and the indoor fan will run at preset speed. When T ambTpreset -1ć, the unit will be stopped under cooling mode, in which case the compressor and outdoor fan will be stopped, while the indoor fan will run at preset speed. When Tpreset -1ć<T amb.< Tpreset +1ć, the unit will maintain its original operating status. ¾ Under cooling mode, the temperature can be set within a range from 16 to 30ć. The initial value is 25ć. The outdoor fan runs at high speed. Tpreset Tamb. start cooling original running status Tpreset stop cooling mins mins mins compressor hign speed hign speed outdoor fan indoor fan set fan speed run stop Dry Mode Drying Conditions and Process When T amb.Tpreset +2ć , the unit will run under cooling mode, in which case the compressor and outdoor fan will started, and the indoor fan will run at low speed. When Tpreset -2ćT amb.Tpreset +2ć , the compressor, indoor fan and outdoor fan will run 6 minutes and stop 4 minutes repeated cycle, while the indoor fan will run at low speed. When T amb.< Tpreset -2ć, the compressor, outdoor fan and indoor fan will be stopped. ¾ Under this mode, the temperature can be set within a range from 16 to 30ć. The initial value is 25ć. The outdoor fan runs at high speed. Tamb. cooling Tpreset drying Tpreset stop running mins mins mins mins compressor outdoor fan indoor fan high speed low speed run high speed high speed low speed low speed stop Heating Mode Heating Conditions and Process When Tamb. Tpreset- 1 , the unit is running in heating mode. Meawhile, the reversing valve, compressor and the outdoor fan start running. When the unit is turned on to turn to heating mode or switch to heating mode from other modes, the four-way valve start running after the compressor is started for the first time in 20s, and the indoor fan will start running after 90s delayed at most. If T amb.Tpreset +1ć , the compressor and outdoor fan will be stopped, while reversal valve will remain energized and the indoor fan will run at low speed for 10s and then it will stop running. When Tpreset -1ć<T amb.< Tpreset +1ć, the unit will maintain its original operating status. Under heating mode, the temperature can be set within a range from 16 to 30ć. The initial value is 25ć. If the unit is switched off under heating mode or switched from heating mode to another mode, the 4-way valve will be de-energized after 2-minute lag. stop heating Tpreset original running status Tpreset start heating mins mins mins compressor outdoor fan low speed low speed indoor fan o run stop Defrosting Conditions and Process When detecting any frost in condenser, the system will start defrosting( The auxiliary electric heater,if any, will be stopped firstly, and then start defrosting after 1 min. ),in which case the compressor, indoor fan and outdoor fan will be stopped simultaneously, the 4-way valve will stop in 3S and the compressor will be started in another 30S.(Defrost will not be detected during high temperature protection).When detecting the frost in condenser is removed, the defrost is completed, in which case the compressor stops, while the 4-way valve runs. 30S later, the compressor starts running,outdoor fan runs,and the indoor fan will run in 90S at least. Auxiliary electric heater working condition When indoor fan is runnng and Tevap. is lower than Tamb. and Tamb. Tpreset-2 , auxiliary electric heater will start running. When indoor fan isn't running, or Tevap. is high, or Tamb. is high, the auxiliary electric heater will stop running. After the auxiliary electric heater is stopped, it can be restarted only after 2min delayed. outdoor fan is running at low fan speed; outdoor fan is running at high fan speed; outdoor outdoor outdoor Outdoor fan keep the original running status. Fan Mode Indoor fan will run at preset speed Auto Speed Low Speed Mid. Speed High Speed ¾The temperature can be set within a range from 16 to 30 . The initial value is 25 ć AUTO Mode Under this mode, the system will automatically select its running mode (cooling, dry, heating or fan) with the change of ambient temperature. ¾ Once a mode is started, the unit will run at least 30 seconds before it can turn to other running status under auto mode according to the ambient temperature. Other Control Sleep Function If the controller is under cooling or dry mode, the preset temperature will be increased by 1ć one hour after running under sleep mode and will be increased by another 1ć after two hours. The temperature will increased by 2ć within two hours. After that, the unit will run at this temperature. Tpreset setting temperature Tpreset Tpreset Tpreset 1hr 2hrs more than 2 hrs If the controller is under heating mode, the preset temperature will be decreased by 1ć one hour after running under sleep mode and will be decreased by another 1ć after two hours. The temperature will decreased by 2ć within two hours. After that, the unit will run at this temperature. 1hr 2hrs more than 2 hrs Tpreset Tpreset setting temperature Tpreset Tpreset No sleep function under fan mode or auto mode. Timer function Timer ON TIMER ON function can be set when the unit is at off mode. At the time for Timer ON, the controller will run under preset mode. The interval of time setting is 0.5h and can be set within 0.5-24hr. Timer OFF TIMER OFF function can be set when the unit is at on mode. At the time for Timer OFF, the system will be stopped. The interval of time setting is 0.5h and can be set within 0.5-24hr . Swing Control You can control its ON and OFF by using the swing button. The swing is valid only when the indoor fan is running. Buzzer When the controller is energized or receives correct signal from press button, the buzzer will give out a beep. Auto fan speed control of indoor fan In this mode, indoor fan will select the fan speed(high, medium, low) according to the change of ambient temperature. Once the fan speed is started, it can be switched according to the condition only after running for 30s. Indicator control The indicator will make a blink when the controller is just energized. The indicator will blink under any condition as below: Defrosting; Antifreeze Protection; Compressor high pressure protection; Compressor low pressure protection;Exhaust pipe high temp. protection; forcible cooling; forcible heating. Power-off Memory Memory content:mode, swing,timer,preset temp.,preset fan speed. After the power is failed, if it's re-energized ,the unit will automatically start to run by the memory of last time. Button MODE button Press MODE key to select and display the run mode as below: FAN button Press FAN key to select and display the run mode as below: AUTO, low, medium, high ¾ Fan speed is not adjustable under dry mode. TEMP setting button (TEMP and TEMP ) 1)Press TEMP. or TEMP. each time, the preset temp. will increase or decrease 1 and the range of adjustment is 16-30 .Under AUTO mode, this button doesn't work. 2) Press the temp. buttons and simultaneously,all the buttons function on the display screen willl be shielded .If press the two keys once again, the shield will be released. (4) Timer Button You can press this button to set the time for AUTO ON when the unit is stopped, or set the time for AUTO OFF when the unit is running. Each press of TIMER button will increase the time setting by 0.5h. If you keep holding down this button, the time setting will automatically increase by 0.5h every 0.5s. The setting range is 0.5-24hr. (5) Swing button Press SWING button once, SWING will be displayed. If indoor fan has been in operation, the swing motor will work. If press this button again, SWING will be disappeared and swing motor will be stopped. (6) ON/OFF button This button is controlling ON/OFF of the controller. After each pressing, the ON/OFF will be switched once. 5 Protection (1) Indoor Antifreeze Protection When the unit is cooling under cooling or dry mode . If it is detected that the system is under antifreeze protection, the indicator will blink and E2 will be displayed, in which case the compressor and the outdoor fan will stop running, while indoor fan and swing motor will maintain the original status. When antifreeze protection is released, the indicator will be black, LCD will resume its display and the controller runs in preset mode. The button is not shielded under antifreeze protection. (2) Compressor High-pressure Protection If high-pressure protection is detected, the unit will close all loads and shield all buttons and remote-control signal, meanwhile, the indicator will blink and E1 will be displayed. Upon detecting that the compressor high-pressure protection is released, the indicator will still blink and E1 wil be displayed, in which case you have to press ON/OFF button to switch off the unit before you can clear E1 display and turn the indicator. Press ON/OFF button to resume the operation. (3) Compressor Low-pressure Protection 1.After the compressor is started for 3mins, if it is detected for 3 minutes successively that the low-pressure switch is broken, the complete unit will be stopped and the indicator will flicker. In 3 minutes, the unit will restore running automatically. If low-pressure switch protection occurs 2 times successively, the indicator flickers and E3 is displayed ,and the unit cannot restore running automatically, so as to remind the user of air leakage. Press ON/OFF button to switch off the unit and press it again to restore operation. 2.Under defrosting mode, low-pressure switch signal can not be detected,which should be done after defrosting finished 10 minutes later. 3.From the controller, you can press down SWING button and FAN SPEED button simultaneously to shield the detection of low pressure switch signal for purpose of air collection. Detection will be resumed automatically after 6 minutes,or you can resume detection by pressing ON/OFF button to switch off the unit and pressing it again to start the unit. 4.Under heating mode,if the outdoor ambient temp. is lower than 0 or equal to 0 ,this detection will be shielded. 5.Under heating mode,if compresoor is running while outdoor fan is stopped(Hi-temp. protection),the detection will be shield till the outdoor fan resumes running. 6.If it is detected that the low-pressure switch is off when the compressor is stopped, the complete unit will be stopped, the indicator will blink and E3 will be displayed, in which case the unit cannot be restarted automatically. You have to press ON/OFF button to switch off the unit and press this button again to restart. (4) Discharge Pipe High-temp. Protection After the compressor is started, if the discharge temperature is too high or exhaust sensor is in short circuit (or open circuit), the indicator will flicker and the unit will be stopped when the indoor ambient temperature reaches the preset value.After the compressor is stopped for 3 mins, the complete unit will be restarted when the discharge temperature is resumed to normal range. If above phenomena occurs twice continuously, the complete unit cannot be restarted automatically, the indicator will blink and E4 will be displayed. Press ON/OFF button to switch off the unit and press it again to switch on the unit. If the discharge temperature is normal, the unit will run under preset mode. If turn on the unit in heating mode or turn to heating mode from other modes, the air discharge temperature will shield 1min for protection when turning on the unit or the compressor is started up for the first time. Indoor ultra-high temp. protection Under heating mode, if it is detected that the temp. of evaporator pipe is too high,the outdoor fan will stop runing(defrosting won't be detected),if temp. gets right, outdoor fan will start running(defrosting will be detected). Low-voltage Protection When the compressor is running,and it is detected that the current exceeds specified value,the unit will stop running when indoor ambient temperature reaches preset temp. After the compressor has stopped for 3 mins, the unit will automatically resume its original running status. If there are more than 6 times protection (If the compressor has stopped for more than 6mins, the times of protection will be cleared),their indicator light flickers and displays E5,and the unit can not resume its original running status. It needs to press the ON/OFF button to stop the unit and repress the button to resume operation. Malfunction and Protection Code E1 Compressor High-pressure Protection Indoor Antifreeze Protection E2 Compressor Low-pressure Protection E3 E4 Exhaust Pipe High-temp. Protection E5 Low-voltage Protection Disassembly procedure of outdoor unit Operating Procedures / Photos 1.Disassemble grill net Unscrew the support chassis between rear plate and valve and 6 tapping screws on condenser side plate, and then remove the grill net. grill net screw screws 2.Disassemble the top cover plate Unscrew the tapping screws around top cover plate and pull it upward, then remove the top cover plate. 3.Disassemble the front plate Unscrew 3 tapping screws on front plate and pull it upward, then remove the front plate. Operating Procedures / Photos 4.Disassemble electric box Unscrew 2 screws on electric box and pull out the signal power wire and the power cord as showed in Fig., and pull it downward, then remove the electric box screws signal power wire 5.Disassemble panel Unscrew 2 screws used for fixing the panel, pull the panel downward and pull out the signal wire, then remove the panel. screws 6.Disassemble air damper and the mounted plate of water tray Unscrew 10 screws around the air damper, and then remove the air damper. Unscrew 2 screws on the mounted plate of water tray and then remove it. screw air damper mounted plate of water tray Operating Procedures / Photos screws 7.Disassemble air-out Assy Unscrew the 3 screws used for connecting air outlet and top cover and the 2 screws used for connecting left plate and right plate air-out assy air-out assy screws 8.Disassemble chassis chassis Unscrew the screws around the chassis and pull it outward, then disassemble the chassis. screw Operating Procedures / Photos 9.Disassemble lower platen of casing Unscrew the 2 screws on the lower platen of casing and pull it upward, then you can remove the lower platen of casing lower platern of casing 10.Disassemble top cover Unscrew the screws around the top cover and then remove the top cover. top cover screw 11.Disassemble air damper and the mounted plate of water tray Press the diversion circle by hand to rotate it in clockwise direction and lift it to remove the diversion circle. As shown in Fig. 12. Unscrew the nut on blade by wrench and lift it diversion circle upward to remove the blade. screws Operating Procedures / Photos nut blade 12.Disassemble mounted plate of evaporator Unscrew the 2 screws on the mounted plate of evaporator and then remove it. mounted plate of evaporator 13.Disassemble the left side and right side plates Unscrew the screws used for connecting the left and right side plates and rear plate, and then remove it. screw screws Operating Procedures / Photos 14.Disassemble casing Unscrew the screws used for fixing the casing and then remove the casingDŽ casing screw 15.Disassemble evaporator Unscrew the 2 screws used for fixing evaporator and then remove evaporator. Unscrew the 4 screws used for fixing the electric heating and then remove it. screws evaporator electric heating parts 16.Disassemble motor Unscrew the screws used for fixing the motor and then remove it. motor screw Operating Procedures / Photos 4.Disassemble the outer case Unscrew the screws around the outer case and then remove it. screw outer case 5.Disassemble electric box Unscrew the screws around the electric box and then remove the electric box assy. screws 6.Disassemble right side plate Unscrew the screws around the right side plate assy and the right side plate assy. right side panel screw Operating Procedures / Photos 7.Disassemble axial blade nut Disboard the nut on blade with wrench and then remove the blade. nut motor 8.Disassemble outdoor motor Unscrew 4 tapping screws used for fixing the motor pull out the leading wire and remove the motor. Unscrew 2 tapping screws used for fixing the motor support, lift it upward and then remove the motor support. fix screw for motor motor support fxing screw 9. Disassemble four-way valve Unscrew the fixing nut of the four-way valve coil and remove the coil. Wrap the four-way valve with wet cotton and unsolder the 4 weld spots connecting the four-way valve to take it out. Welding process should be as quick as possible and keep wrapping cotton wet all the time. Be sure not to burn out the leading wire of compressor. four-way valve Operating Procedures / Photos 10. Disassemble valve Unscrew 2 screws used for fixing the valve and unsolder its connection pipe, the remove the valve. gas valve screw screws liquid valve 11.Disassemble capillary Unsolder the weld spot used for connecting capillary and other pipes and then remove the capillary. capillary 12.Disassemble compressor Unscrew 4 foot screws of compressor and unsolder the connection pipes, then remove the compressor. foot nut 8 Assembly Drawing and Parts List Assembly drawing for indoor unit parts Parts list for indoor unit No Description 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 Left Side Plate Sub-Assy Rear Plate Sub-Assy Top Cover Sub-Assy Right Side Plate Sub-Assy Evaporator Assy Water Tray Sub-Assy Temperature Sensor Electric Heater Tube Breakwater Sub-Assy Propeller housing press plate sub-assy Rear Grill Air Guard Assy Front Panel Assy Air Outlet Assy Display crank Synchronizing Motor Air Louver Filter Sub-Assy Air Intake panel Assy Electric Box Cover Sub-Assy Fuse Relay Relay Main Board Capacitor CBB61 Transformer Terminal Board Electric Box Assy Protective covering Diversion Circle Propeller Housing Sub-assy Centrifugal fan Fan Motor Chassis Rear Cover Baffle Plate Connecting Cable Connecting Cable Connecting Cable Drain Pipe Part Code FS 1060Ai 01304305 01304177 22244470 01304179 01004283 12414471 39000171 32004053 01364483D 01364471 01474034 01364496 20004386 2000447001 30543070 10564201 15214215 10514452 11144471 200044711 01404403 46010013 44020331 44020345 30033066 33010037 43110237 42010258 01404334 01474027 10374202 12104470 10314401 15014431 22224471 2224422002 2611408802 40030311 40030309 40030310 05230022 Qty 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 6 1 1 1 1 3 7 1 1 1 1 1 1 1 1 1 1 1 3 3 2 1 1 1 Assembly drawing for outdoor unit Parts list of outdoor unit No Description 1 Panel Grille Part Code FS 1060Ao 22414102 2 3 4 Cabinet Rear Grill Top Cover 01435436 01475432 01255472 1 1 1 5 6 7 Rear Side Plate Sub-Assy Handle Valve Support Sub-Assy 01303712 26235253 01715001 1 2 1 8 9 10 Chassis Sub-assy Front Side Plate Sensor supprt 01205472 01305431 24211341 1 1 1 11 12 13 Axial-flow Fan Condenser Assy Motor Support Sub-Assy 10335253 01105341 01705471 2 1 1 14 15 16 Fan Motor Mid-clapboard sub-assy Inhalation Tube Sub-Assy 15015451 01235473 03639066 2 1 1 17 18 19 4-way Valve Assy 4-way Valve Accessary Compressor and fittings 03025268 430004002 00129052 1 1 1 20 21 22 Assistant Capillary Sub-Assy Cut-off Valve 3/4(R410A) Electric heater(compressor) 03005283 07130212 76515404 1 1 1 23 24 Condenser support sub-assy Temperature Sensor 01894148 39000129 1 1 25 26 27 Air-out Temp. Sensor Outdoor Tube Sensor Electric Box Assy 39000163 39000127 014054709 1 1 1 28 29 30 AC Contactor Over Current Protector Transformer 44010236 46020103 43110242 1 1 1 31 32 33 Relay Terminal Board Capacitor CBB61 44020332 42010258 33010013 1 2 2 34 35 36 Phase Reverse Protector Relay Terminal Board 46020052 44020369 42011103 1 1 2 37 38 39 Drainage Connecter Drainage Plug Pressure Protect Switch 06123401 06813401 460200061 1 2 1 40 Low pressure switch 46020007 1 Qty 2 9 Troubleshooting When setting the circuit breaker at "ON", it will be tripped off immediately Ground and measure the insulation resistance, confirm whether the A/C is leaking Breaker is tripped over or the fuse is burnt out When the A/C is turn to "ON", the circuit breaker will be tripped off in a few minutes Check the circuit breaker No power supply Check the power supply circuit The power plug hasn't been inserted well or poor connection Wrong wire connection between outdoor unit and indoor unit A/C can't be started up Check the remote controller Fuse of controller is burnt out Replace the fuse of controller Indoor unit and outdoor unit can't be started up Whether the outlet wire of transformer is firm, and whether there's output volatage Setting temperature is unreasonable Whether ccoooing(heating) load is inapproprite Flow malfunction of refrigerant Check whether the wire connection is wrong according to the electric circuit diagram , and connect it correctly Malfunction of remote controller Whether the wire between stronge electric plate and weak electric plate is connected firmly Poor (heating) or cooling Check and insert the plug well Connect the wire firmly Please connect the wire firmly and check the output volatege Adjust the setting temperature Check the forecast cooling(heating)load Malfunction of four-way valve Replace four-way valve Refrigerant volume is insufficient Fill with refrigerant Malfunction of compressor Replace compressor Flow of valve is insufficient Increase the valve flow Clean the filter Filter is blocked Air circulation is insufficient Fan speed is set too low Installation position for the outdoor unit is improper Set the fan speed to high or medium The ventilation for the outdoor unit should be good. You can install the rain-proof and sun-proof board. Poor (heating) or cooling Outdoor's unit filter is blocked Clean filter periodically Outdoor unit's heat exchanger is blocked Clean the dust accumulated on the surface of heat exchanger There's leakage between high voltage and low voltage in compressor Part of compresser is blocked Refrigerant is leaking One-way valve of outdoor unit is blocked Indoor fan's motor is burnt our or its wire is broken When setting fan blowing, the fan can't run Repair it or replace fan's motor Fan's capacitor is open circuit or damaged Replace fan's capacitor with the same model and specification Replace the relay Relay hasn't been connected well Outdoor fan's motor is broken Wrong wire connection Outdoor fan's capacitor is damaged Malfunction of the compressor In cooling or heating mode, the outdoor fan is running, while the compressor doesn't run Replace the one-way valve Connect the wire correctly according to the electric circuit diagram The setting temperature is improper In cooling or heating mode, the compressor is running, while outdoor fan don't run Check the leakage and add refrigerant Wrong wire connection Relay coil's wire is broken In cooling or heating mode, the outdoor unit and the compressor don't run. Replace the compressor Adjust the setting temperature Replace the fan's motor Connect the wire correctly according to the electric circuit diagram Replace the fan's capacitor Replace the compressor Rotating capacitor of compressor is broken Replace the capacitor Voltage is a little low or high Suggest to equip with the voltage regulator Wrong wire connection Connect the wire correctly according to the electric circuit diagram Replace the compressor Drain pipe is blocked or broken Replace the drain piple The junction of the refrigerant pipe hasn't been wrapped well Wrap it again and wrap it tightly Leakage The fan of indoor unit will contact other parts There are foreign substances in the indoor unit Abnomal sound and vibration Adjust the fan's position Take out the foreign substances Abnormal vibration for the compressor Adjust the compressor's support mat and fasten the loose bolt The pipes for outdoor unit are in collision with each other Separate the collision pipes Metal plates in the unit are in collision with each other. 1. Tighten the screws 2. Stick the damping plaster among metal plates The blade of outdoor unit is in collision with the outer case Adjust the blade's position There is abnormal sound in the compressor Replace the compressor There is abnormal electromagnetic sound in the four-way valve when heating Electromagnetic valve is short-circuit ; please replace it. Notice: there's no malfunction in respect of heating for cooling only units.
advertisement
Key Features
- Cooling, heating, fan and dry modes
- Sleep function
- Timer function
- Swing control
- Auto fan speed
- Power-off memory
- Compressor high-pressure protection
- Compressor low-pressure protection
- Discharge pipe high-temp. protection
- Low-voltage Protection
Frequently Answers and Questions
How do I choose the right temperature setting for my split-system air conditioner?
It depends on your personal preference and the desired room temperature. During cooling mode, set the temperature within a range from 16 to 30°C, while heating mode allows a range of 16 to 30°C.
What does the 'sleep function' do?
When the sleep function is activated, the set temperature will increase by 1°C after one hour and by another 1°C after two hours. The temperature will increase by 2°C within two hours. After that, the unit will run at this temperature.
How do I set the timer function?
The Timer ON function can be set when the unit is at off mode. At the time for Timer ON, the controller will run under preset mode. The interval of time setting is 0.5h and can be set within 0.5-24hr. The Timer OFF function can be set when the unit is at on mode. At the time for Timer OFF, the system will be stopped. The interval of time setting is 0.5h and can be set within 0.5-24hr.
What are the different protection functions of the air conditioner?
The air conditioner has multiple protection functions, including compressor high-pressure protection, compressor low-pressure protection, discharge pipe high-temp. protection, and low-voltage protection. These functions help to prevent damage to the unit and ensure its safe operation.