Star FGR006, SR, EX, IP-FGR006 Fingerprint & Proximity Reader User’s Manual
Below you will find brief information for Fingerprint & Proximity Reader FGR006, Fingerprint & Proximity Reader FGR006 SR, Fingerprint & Proximity Reader IP-FGR006, Fingerprint & Proximity Reader FGR006 EX. This manual describes the installation, configuration, and operation of the Star FGR006 Fingerprint & Proximity Reader. This device is designed for access control systems and provides access to authorized users using both fingerprint and proximity card. It features built-in proximity reader, fingerprint module and external reader port (in FGR006EX model). It allows you to replace old readers with this modern device and manage access permissions based on user fingerprint and card ID.
advertisement
Assistant Bot
Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.
Fingerprint & Proximity Reader
USER’S MANUAL
Fingerprint & Proximity Reader
Rev.4.2.0
Table of Contents
Fingerprint & Proximity Reader
1. Important Safety Instructions............................................................................3
2. General ................................................................................................................3
3. Features...............................................................................................................4
4. Identifying Supplied Parts .................................................................................4
5. Specification .......................................................................................................4
6. Product Overview ...............................................................................................5
6.1. Functions .....................................................................................................5
6.2 PRODUCT EXPLANATION ...........................................................................6
6.2.1 PANEL DESCRIPTION.........................................................................6
6.2.2. Color Coded & Wiring Table..............................................................6
7. Installation Tips & Check Point .........................................................................7
7.1. Recommended cable type and permissible length of cable....................7
7.2. Reader connection ......................................................................................7
8. Installation of the Product .................................................................................8
8.1. Mullion and Wall Mount...............................................................................8
8.2. System Initialization ....................................................................................9
8.3. Wire Connection of FGR006 .......................................................................9
8.4. Wire Connection of FGR006EX ..................................................................9
8.5. Network Connection of FGR006...............................................................10
8.6. Wiring Example..........................................................................................10
9. Communication.................................................................................................11
9.1. Address Setting for RS485 / RS422 Communication .............................11
9.2. Address Setting for RS232 Communication Port Connection ..............12
9.3. Address Setting for RS485 Communication Port Connection ..............12
10. Operation.........................................................................................................13
11. Operation Indication of Reader / Register ....................................................17
12. FCC Registration Information........................................................................18
2
Fingerprint & Proximity Reader
1. Important Safety Instructions
When using your Single Door Controller, basic safety precautions should always be followed to reduce the risk of fire, electrical shock, and injury to persons. In addition, the following should also be followed:
1. Read and understand all instructions.
2. Follow all warnings and instructions marked on the product.
3. Do not use liquid cleaners or aerosol cleaners. Use a damp cloth for cleaning. If necessary, use mild soap.
4. Do not use this product near water, such as bath-tub, wash bowl, kitchen sink, laundry tub, in a wet basement, or swimming pool.
5. This product should be operated only from the type of power source indicated on the marking label.
If you are not sure of the type of power supplied to your installation site, consult your dealer or local power company.
6. Never push objects of any kind into this product or through the cabinet slots as they may touch voltage points or short out parts that could result in fire or electric shock. Never spill liquid of any kind on the product.
7. To reduce the risk of electric shock, do not disassemble this product by yourself, but take it to qualified service whenever service or repair is required. Opening or removing the covers may expose you to dangerous voltages or other risks. Also, incorrect reassembly can cause electric shock when the unit is subsequently used.
8. Unplug this product from the Direct Current (DC) power source and refer to qualified service personnel under these conditions: a. When the power supply cord or plug is damaged or frayed. b. If liquid has been spilled on the product. c. If the product does not operate normally after following the operating instructions in this manual.
Adjust only those controls that are covered by the operating instructions in this manual.
Improper adjustment of other controls that are not covered by this manual may damage the unit and will often require extensive work by a qualified technician to restore normal operation. d. If the product exhibits a distinct change in performance.
2. General
The STAR FGR006 is a Biometrics and Proximity Reader which is compatible to existing proximity readers. The STAR FGR006 can be connected to any existing access control panel and you will have personal authorization by one’s fingerprint to avoid any access from un-authorized person. The
STAR FGR006 has built-in proximity reader (The STAR FGR006EX has external reader port) and fingerprint module so that the access is only allowed when the personal ID and fingerprint are authorized. Its modern design gives you an easy installation (just replace existing reader) to metal door frame (mullion) or to any flat wall surface. The STAR FGR006 ensures you a successful operation where you want biometrics access control. The STAR FGR006 has three LED of red, green and lens(upper right), inside beeper sound to guarantee you an accurate and reliable access control.
3
Fingerprint & Proximity Reader
3. Features
- Proximity/PIN and Fingerprint Verification
- Dual fingerprints registration
- Stores up to 1,000/2,000/4.000 Fingerprints
- 1:1Verification and 1: N Identification
- RS232 communication port for upload/download Fingerprints using PDA or Notebook (Optional)
- Registration / Verification mode using Master Card
- Off-line Add/Delete function using Master Card
- External Reader Port to work with existing Proximity Reader
- (26bit Wiegand) or Keypad / Magnetic stripe Reader(FGR006EX)
- 26bit Wiegand, ABA TrackⅡ
- High Protection from Scratch and ESD (Electro Static Discharge)
- Tamper switch
- High Quality Optical Sensor
4. Identifying Supplied Parts
Please unpack and check the contents of the box.
Main Unit Bezel User’s Manual RS232 Serial Port
(Optional)
5. Specification
CPU
Memory
Power / Current
Data Format
Output Format
32bit Microprocessor and Dual 8bit Microprocessor
Program Memory : 64KB EEPROM
DC 12V / Max. 350mA
User
1,000 / 2,000 / 4,5000 available
Reader Port
(FGR006EX only)
1ea of external reader port
26bit Wiegand, 8bit burst Format for keypad reader
26bit Wiegand, ABA Track II Magstripe format
(Caution : Card Present signal is Open Collector)
RS232, RS485, RS422(default, up to 255ch) selectable
Communication
LED Control Input
4800bps and 9600bps (Default)
19200bps, 38400bps, 57600bps and 115200bps (Optional)
Low active, maximum 20mA current drain (RS485)
4
Buzzer Control Input
Tamper Switch
LED Indicator / Beeper
Color
Operating Temperature
Operating Humidity
Dimension (W x H x D)
Weight
Fingerprint & Proximity Reader
Low active, maximum 20mA current drain (RS485)
Low active
3 LED Indicators / Piezo Buzzer
Light and Dark Gray
-15℃ to 40℃ (-5℉ to 104℉)
10% to 90% relative humidity non-condensing
2.6"x5.1"x2.0" (66x129x51mm)
230g (0.5 lbs)
6. Product Overview
6.1. Functions
The FGR006 is finger reader with integrated proximity reader and registration terminal.
Registration Mode
The registration mode registers or eliminates user cards.
Reader Mode
This function uses as reader.
RF Only Mode
: If card data is authorized, card ID will be transmitted to controller.
RF + FINGER Mode
: If fingerprint data is authorized, card ID will be transmitted to controller.
Master Card
A master card is used when it changes mode each other.
Card Number Output Form
If your fingerprint is authorized then output becomes the card number to 26bit Wiegand or
ABA Track II according to an output type.
Error Signal Output
If your fingerprint is not authorized then FGR006(FGR006EX) will generate finger error signal for
500ms of low active pulse.(Only available when your FG006(FGR006EX) is set to 26bit Wiegand output) This signal is open collector.
Card Number Input Form
This function is only available when you use FGR006EX.
5
Fingerprint & Proximity Reader
FGR006EX is input the card number in the outside but FGR006 is contained internally.
It takes a card input in a 8bit Burst or 26bit Wiegand or ABA Track II form .
6.2 PRODUCT EXPLANATION
6.2.1 PANEL DESCRIPTION
6.2.2. Color Coded & Wiring Table
IO PORT NAME
POWER
Main Power(+12V)
Power Ground
SIGNAL NAME
+12V
GND
INPUT (Only available with RS232/RS485 Communication)
LED Control Input LED
Buzzer Control Input
WIEGAND OUTPUT
Wiegand Data-0
BEEP
DATA0
COLOR CODED
RED
BLACK
BROWN
BLUE
GREEN
Wiegand Data-1
* Finger Error
DATA1
ERROR
WHITE
ORANGE
* Note that the Finger Error output is only available with Wiegand output.
ABA TRACK II OUTPUT
Card Present CLS Orange
RS485 COMMUNICATION PORT
6
Fingerprint & Proximity Reader
RS422 COMMUNICATION PORT Î DEFAULT
RS422 TX+ RS422 TX+
RS422 TX- RS422 TX-
RS422 RX+
RS422 RX-
TAMPER SWITCH
Tamper Switch
RS422 RX+
RS422 RX-
RS422 TX+
RS422 TX-
RS422 RX+
RS422 RX-
EXTERNAL READER PORT (FGR006EX Only)
Wiegand Data-0 Wiegand Data-0
Wiegand Data-1 Wiegand Data-1
Wiegand Data-0
Wiegand Data-1
7. Installation Tips & Check Point
7.1. Recommended cable type and permissible length of cable
Reader (Power and Data)
Reader -> ACU
Belden #9512, 22 AWG
4 conductor, shielded
Belden #9514, 22 AWG
8 conductor, shielded
150m
* Need thicker wire if you connect the reader with high current consumption.
7.2. Reader connection
If you install the reader in a long distance between the ACU and the reader, you have to remind that there will be a voltage drop between both ends of GND wire. For example, if you connect a reader with
100mA current consumption at 100m distance (assume to using DC resistance of cable of
100Ω/100m) and the reader power is supplied from the ACU, the voltage drop of the GND wire will be
1V. In this case, the Wiegand data signal can not be measured lower than 1V.
The most of ACU is capturing the signal by the voltage level of data input and 1V is the critical point whether the ACU read the data logic “1” or logic “0” therefore the reader output can not be read correctly from the ACU.
You have to think about how you reduce the voltage drop between both ends of GND wire.
There will be two methods to reduce the voltage drop and ACU can read data correctly.
Reduce the DC resistance of GND wire; Using thick cable or add more wires to GND wire in parallel. If you connect 4 wires in parallel for GND, the DC resistance of GND
wire will be reduced to 1/4 of single wire.
Use separate power for the reader; Disconnect +12V wire from the ACU and connect external power supply to the reader nearby then there will be no current flow through the GND wire and no voltage drop between both ends of GND wire
.
7
Shield
Fingerprint & Proximity Reader
EARTH GND
< Reader connection using additional wires >
EARTH GND Shield
< Reader connection using external power supply >
8. Installation of the Product
8.1. Mullion and Wall Mount
8.1.1 Drill two Ø1/8"(3mm) holes, 4.4"(113mm) apart in vertical and drill one Ø1/2" hole for the reader cable 2.2"(56mm) apart from the top hole.
8.1.2 Connect wires between the control panel and FGR006 reader then put reader cable into the center hole and install the main unit by using two 3-16 screws.
8.1.3 Put bezel into the main unit then push bezel until you hear the locking sound.
8
Fingerprint & Proximity Reader
8.2. System Initialization
You can H/W initialize using DIP switches.
First, turn on the system power and turn off all
DIP switches.
Set DIP switches after an initialization completion.
* DIP Switch as used as address of RS422/RS485 communication.
An Initialization situation refers to the "11.Operation Indication of Reader / Register" of manual.
8.3. Wire Connection of FGR006
8.4. Wire Connection of FGR006EX
9
Fingerprint & Proximity Reader
8.5. Network Connection of FGR006
8.6. Wiring Example
8.6.1 Power
- Connect (+) wire of DC 12V power to Red wire
- Connect Power GND(-) wire of DC 12V to Black wire
8.6.2 Input Connection (Only available with RS232/RS485 communication)
- A green LED turns on if the short does LED CONTROL INPUT wire with the GND.
- The beep sound appears if the short does BEEPER CONTROLER
INPUT wire with the GND.
10
Fingerprint & Proximity Reader
8.6.3 Output Connections
[ 26bit Wiegand Output] [ABA Track II Output]
8.6.4
External Reader Connection (FGR006EX Only)
9. Communication
A communication setting up is basically RS422.
If you need the change of the communication mode separate FGR006(FGR006EX) and must set the jumper of MAIN PCB part.
A jumper setting up uses a soldering iron.
9.1. Address Setting for RS485 / RS422 Communication
There is 8bit DIP SW for address setting and it turns to 8bit binary code as below and each bit has fixed address value, the address is calculated the sum value of each bit set to “1” position.
11
Fingerprint & Proximity Reader
9.2. Address Setting for RS232 Communication Port Connection
You should use external RS232 serial cable.
- Connect connector for serial communication finished wiring on COM1 or COM2 port of PC.
- Install application software and then execute it.
※
Please refer to 10.5 External RS232 Serial Jack (OPTION 2)
9.3. Address Setting for RS485 Communication Port Connection
FGR006(FGR006EX) Wire CNP-200A Converter Wire
GRAY RS485-A RED RS485-A
YELLOW RS485-B GRAY RS485-B
Set the jumper as shown in the figure above.
RS-485/RS-232 converter is required to connect serial communication RS485 between Main Unit and PC(Personal Computer). The converter is CNP200A.
- Connect RS485 A, Gray wire of Main Unit to Red wire of CNP200A converter.
- Connect RS485 B, Yellow wire of Main Unit to Gray wire of CNP200A converter.
- Plug the RS232 9-pin connector of CNP200A converter into COM1 or COM2 Port of PC.
- Install and run the application software.
12
9.4. RS422 Communication Port Connection
Fingerprint & Proximity Reader
FGR006(FGR006EX) Wire
CNP-200A Converter
Wire
YELLOW RS422-Tx[-] WHITE Rx-
GRAY RS422-Tx[+] RED Rx+
BLUE RS422-Rx[-] BLACK Tx-
BROWN RS422-Rx[+] BLUE Tx+
Set the jumper as shown in the figure above.
RS422/RS232 converter is require to connect serial communication RS422 between Main Unit and
PC(Personal Computer). The converter is CNP200A.
- Connect RS422 Tx[-],Yellow wire of Main Unit to White wire(Rx[-] port) of CNP200A converter.
- Connect RS422 Tx[+], Gray wire of Main Unit to Red wire(Rx[+] port) of CNP200A converter.
- Connect RS422 Rx[-], Blue wire of Main Unit to Black wire(Tx[-] port) of CNP200A converter.
- Connect RS422 Rx[+], Brown wire of Main Unit to Blue wire(Tx[+] port) of CNP200A converter.
- Plug the RS232 9-pin connector of CNP200A converter into COM1 or COM2 Port of PC.
- Install and run the application software
10. Operation
10.1. Master Card Registration Mode
10.1.1 Master Card Registration
The card presented to the FGR006 for the first time after initialization becomes the master card.
A master card registration mode situation refers to the "11.Operation Indication of
Reader / Register" of manual.
※ Note: Master card is not using the master fingerprint
10.1.2 Master Card Change
You can register Master Card again after initialization of hardware.
※ CAUTION : If you initialize hardware, all user data are deleted.
You can change master card by using the application software.
Using the application software keeps the user data unchanged.
Please refer the FGR006 software manual for download master card.
10.1.3 Master Card Function.
It is used as the key to change reader and registration mode mutually
※ For example
In the Reader mode if you access master card, it is changed to registration mode.
In the Registration mode if you access master card again, it is changed to reader mode.
13
Fingerprint & Proximity Reader
10.2. Reader Mode
10.2.1 Reader Mode Function.
A reader mode authorize user card.
If your fingerprint is authorized then the output is your card ID.
If your fingerprint is not authorized then output is error signal.
A reader mode situation refers to the "11.Operation Indication of Reader / Register" of manual.
10.2.2 Authorization Method
Present proximity card to the FGR006
Present proximity card to the external reader(FGR006EX only)
If your card ID is registered, fingerprint scanner will light on.
If your card ID is not registered, FGR006(FGR006EX) will make 2 beep sounds and return to the reader mode.
9 RF + FINGER MODE: Put your finger on the fingerprint scanner for authorization.
If your fingerprint is authorized then FGR006(FGR006EX) will turn on the lens. LED(upper light) indicator make a beep sound for a second and send your card ID to the access controller.
9 RF Only: If card is authorized only without using fingerprint, LED(upper light) indicator make a beep sound for a second and send your card ID to the access controller.
If your fingerprint is not authorized then FGR006(FGR006EX) will make 2 beep sounds and generate finger error signal for 500ms of low active pulse.(Only available when your
FGR006(FGR006EX) is set to 26bit Wiegand output)
10.3. Registration Mode
10.3.1 Registration Mode Function
The mode is the register an user card or to delete.
It deletes the card when an user card is registered. (4 beeps sounds)
It registers the card when an user card is not registered. (3 beep sounds)
10.3.1 User Card Registration.
9 RF + FINGERPRINT MODE:
After reading user’s card, you should register fingerprint two times.
Present the proximity card to the FGR006
Present the proximity card to the external reader (FGR006EX only)
Put the fingerprint when red light is illuminated on the fingerprint scanner.
Put the fingerprint again on the fingerprint scanner when the red light is illuminated again after the red light turns off.
It beeps 3 times when the registration is completed.
14
Fingerprint & Proximity Reader
9 RF Only:
Don’t place your finger on fingerprint scanner after reading user’s card.
It beeps 3 times when the registration is completed.
Register by method such as above, if there are cards to register additionally.
After registration present proximity master card again, and it is changed to the reader mode. It beeps 2 times when the registration is not correct.
10.3.2 User Card Deletion
Present the proximity card to the FGR006
Present the proximity card to the external reader(FGR006EX only)
It beeps 4 times when the deletion is completed.
After deletion present proximity master card again, and it is changed to the reader mode. It beeps 2 times when the deletion is not.
10.4. Identification Function (OPTION 1)
This function operates in the Reader mode.
User can be verified with Fingerprint template only. (No card necessary)
Sensor will be activated automatically when user place the fingerprint on the fingerprint scanner.
※
CAUTION : This function must be applied when the number of user is less than 100.
If your fingerprint is authorized then FGR006(FGR006EX) will turn on the lens led(upper light) and make a beep sound for a second and will send your card ID to the access controller.
If your fingerprint is not authorized then FGR006(FGR006EX) will make 2 beep sounds and generate finger error signal for 500ms of low active pulse.(Only available when your FGR006
(FGR006EX) is set to 26bit Wiegand output)
10.5. External RS232 Serial Jack (OPTION 2)
This function use in FGR006 to PC(or Notebook) when it connect directly.
This function is possible the software though FGR006 are established to a stand alone type.
15
Fingerprint & Proximity Reader
It use to connect with FGR006 and
RS232 port of PC(or notebook).
It uncover TOP CASE in FGR006.
Extract after you pull TOP CASE bottom of
FGR006.
It insert RS232 serial jack at bottom of
FGR006
It connect a d-sub connector with RS232 port of PC (or notebook).
16
11. Operation Indication of Reader / Register
FGR006 : over the version 3.00
FGR006EX : over the version 3.00
11.1. LED Indicators Status
LED STATUS
Booting
Fingerprint & Proximity Reader
FUNCTION
The system is booting when power is supplied
Register
Master Card
The unit is initialized and master card is unregistered
Registration Mode Add / Delete user
Reader Mode Verify user card
Initialization The unit is initialized
Initialization
Completed
System initialization is completed
11.2. Buzzer Sound Status
BEEP SOUND TIMES
1 time(1second)
2 times
3 times
4 times
Access granted.
Register user card.
STATUS
Error(Fingerprint or operation error)
Delete user card.
17
Fingerprint & Proximity Reader
12. FCC Registration Information
FCC REQUIREMENTS PART 15
Caution: Any changes or modifications in construction of this device which are not expressly approved by the responsible for compliance could void the user's authority to operate the equipment.
NOTE: This device complies with Part 15 of the FCC Rules.
Operation is subject to the following two conditions;
1. This device may not cause harmful interface, and
2. This device must accept any interference received, including interference that may cause undesired operation.
This equipment has been tested and found to comply with the limits for a Class A Digital Device, pursuant to Part 15 of the FCC Rules. These limits are designed to this equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the radio or television off and on, the user is encouraged to try to correct interference by one or more of the following measures.
1. Reorient or relocate the receiving antenna.
2. Increase the separation between the equipment and receiver.
3. Connect the equipment into an outlet on another circuit.
4. Consult the dealer or an experienced radio/TV technician for help.
18
advertisement
Key Features
- Proximity/PIN and Fingerprint Verification
- Dual fingerprints registration
- Stores up to 1,000/2,000/4.000 Fingerprints
- 1:1Verification and 1: N Identification
- RS232 communication port for upload/download Fingerprints using PDA or Notebook
- Registration / Verification mode using Master Card
- Off-line Add/Delete function using Master Card
- External Reader Port to work with existing Proximity Reader
- High Protection from Scratch and ESD
- Tamper switch