Miniature Fiber-Optic
3G-SDI Extension Module
User’s Manual
(SDIX-100, SDIX-100C)
Manual Contents
______________________________________________________
Installation
Troubleshooting, Maintenance, Technical Support
1-3
1-5
Pictorials
Figure 1 – Fiber-Optic 3G-SDI Extension module, SDIX-100 1-1
Figure 2 – Tx Module of SDIX-100
Figure 3 – SDIX-100 with power adapter
1-2
1-3
Figure 4 – Rx Module of SDIX-100(C)
Figure 5 – Whole Connection of SDIX-100(C)
1-4
1-5
1- 0 Manual Contents
Welcome!
Congratulations on your purchase of the Miniature Fiber-Optic 3G-SDI
Extension module, SDIX-100, SDIX-100C. This manual contains information that will assist you in installing and operating the product.
Product Description
Shipping Group
SDIX-100-Tx, Rx Module: One (1) set of unit, length as your request.
Option) SDIX-100-Tx/Rx, SDIX-100C-Tx/Rx (Including re-clocker)
DC 5V 1.5A power adapter : Two (2) units
+12V power supply cable directly from camera (Option)
User’s Manual
Plastic hard case
Figure 1 – Fiber-Optic 3G-SDI Extension module, SDIX-100
1-1 Welcome, Product Description
System Requirements for Setup
Hardware requirements
You have to have a SDI multimedia systems (Camera, OB Van,
Broadcasting equipment using SDI signal, SDI Monitor etc.) or it should support the maximum graphic resolution feature of
Monitors to be connected.
No special requirements of memory size, CPU speed and chipsets, if you’ve already properly installed your SDI systems.
Software requirements
No special restrictions, if you’ve already properly installed your
SDI systems.
DC Power Adapter Technical Advisory
The SDIX-100(C) is designed to use only +5V external power.
Installation
Important: Please follow the installation procedure as below. Improper, or no operation may result if the start-up sequence is not correctly followed.
Step 1
Carefully unpack the contents of the shipping group.
Step 2
Connect the plug of the Tx side of SDIX-100 to the receptacle of SDI source
(Camera, Broadcasting equipment etc.) directly. Do NOT recommend to use any intermediate cable or adapter between them. It may deteriorate the signal transmission performance.
Figure 2 – Tx module of SDIX-100
Step 3
As shown in Figure 3, plug the +5V power adaptor in the shipping group to the
Tx & Rx Module.
Connecting 5V power adaptor to SDIX-100 Cable is indispensable procedure for working.
1-2 System Requirements for Setup
1-3 Installation
Figure 3 –SDIX-100 with power adapter
Step 4
Connect the Rx side of SDIX-100(C) to the SDI receptacle of a Display directly. Do NOT recommend to use any intermediate cable or adapter between them. It may deteriorate the signal transmission performance.
Figure 4 – Rx module of SDIX-100(C)
Step 5
Power ON the SDI source and Display.
Note: Both of Tx and Rx modules of SDIX-100(C) must be connected by
+5V power adaptors.
Figure 5 – Whole Connection of SDIX-100(C)
Step 7
If the system does not work properly, go to page 1-5, trouble shooting.
1-4 Installation (continued)
Troubleshooting
The display shows only black screen.
Ensure that all AC and DC plugs and jacks used by external power supplies are firmly connected.
Ensure that the SDI connector is firmly plugged in to the SDI source and SDI display. Ensure that the Tx and Rx module parts plug correctly to the SDI source and SDI display, respectively.
Check if the SDI source and SDI display are powered on and properly booted.
Reset the system by de-plugging and re-plugging the Tx SDI module or Rx
SDI module. Re-boot up the system while connecting the SDIX-100(C).
Screen is distorted or displays noises.
Ensure the quality of SDI source and check the extension length of fiber.
SDIX-100 guarantee 30Km@3G
Maintenance
No special maintenance is required for the SDIX-100 and power supplies.
Ensure that the cables and power modules are stored or used in a benign environment free from liquid or dirt contamination.
There are no user serviceable parts. Refer all service and repair issues to
Opticis.
Technical Support and Service
For commercial or general product support, contact your reseller. For technical service, contact Opticis by email [email protected]
or visit its website at www.opticis.com.
1-5 Troubleshooting, Maintenance, Technical Support
Product Specifications
SDIX-100(C), Fiber-Optic 3G-SDI Extension module
Transmission of Multi-rate HD-SDI Digital Video over 1 Fiber :
It converts and transport one(1) channel SMPTE-424M, 3G-SDI,
SMPTE-292M, HD-SDI or SMPTE-259M, SD-SDI.
Available both Single-mode and Multi-mode.
Offers clock recovery circuit included model, SDIX-100C as an option.
Extension limit: 30km @3G, 1080p 3G-SDI format.
Recommended Fiber-optic Cable: Glass Single-mode fiber with
1310, 1550nm of bandwidth and ST terminated connector.
General electrical specification
Data Transfer Rate (Graphic Data) : Max. 3Gbps
Link Power Budget : Min.11dB
Optical Connector : ST Connector
Electric Connector Type from Modules : 75 Ohm BNC (Male)
Mechanical specifications of Tx and Rx module parts
Dimensions: 19.5mm / 19.5mm / 82.7mm (W/H/D)
Environmental Specifications
Operating temperature: -20°C to 70°C
Storage temperature: - 30°C to 85°C
Humidity: 5% to 95% RH
DC Power Adapter
Supply Power : DC 5V, 1.5A
Cord DC Jack : Core is 5V and outer is GND.
1-6 Product Specifications
Warranty Information
1 (One) Year Warranty
Opticis warrants this fiber-optic 3G-SDI extension cable to be free from defects in workmanship and materials, under normal use and service, for a period of one (1) year from the date of purchase from Opticis or its authorized resellers.
If a product does not work as warranted during the applicable warranty period,
Opticis shall, at its option and expense, repair the defective product or part, deliver to customer an equivalent product or part to replace the defective item, or refund to customer the purchase price paid for the defective product.
All products that are replaced will become the property of Opticis.
Replacement products may be new or reconditioned.
Any replaced or repaired product or part has a ninety (90) day warranty or the reminder of the initial warranty period, whichever is longer.
Opticis shall not be responsible for any software, firmware, information, or memory data of customer contained in, stored on, or integrated with any products returned to Opticis for repair under warranty or not.
Warranty Limitation and Exclusion
Opticis shall have no further obligation under the foregoing limited warranty if the product has been damaged due to abuse, misuse, neglect, accident, unusual physical or electrical stress, unauthorized modifications, tampering, alterations, or service other than by Opticis or its authorized agents, causes other than from ordinary use or failure to properly use the Product in the application for which said Product is intended.
Dispose of Old Electrical & Electronic Equipment
(Applicable in the European Union and other European countries with separate systems)
This symbol on the product or on its packaging indicates that this product shall not be treated as household waste. Instead it shall be handed over to the applicable collection point for the recycling of electrical and electronic equipment. By ensuring this product is disposed of correctly, you will help prevent potential negative consequences for the environment and human health, which could otherwise be caused by inappropriate waste handling of this product.
The recycling of materials will help to conserve natural resources. For more detailed information about recycling of this product, please contact your local city office, your household waste disposal service or the shop where you purchased the product.
1-7 Warranty Information
FCC/CE Statement
This device complies with part 15 of FCC Rules and EN 55022/61000-3 for
CE certification. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 and 2 of FCC Rules and
EN 55022/61000-3 for CE certification. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and. if not installed and used in accordance with the instruction guide, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the
• interference by one or more of the following measures:
•
•
•
Re-orient or relocate the receiving antenna.
Increase the separation between the equipment and the receiver.
Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
Consult a service representative for help.
Properly shielded and grounded cables and connectors must be used in order to comply with FCC/CE emission limits. Changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment.
UL Statement
This device has completed a UL Commercial Inspection and Testing Services for the multimode DVI cable complied with VW-1 under UL 758. It is validated by the UL file number SV2038 and project number 04CA05353.
1-8 Regulatory Statements
UL/IEC Statement
This equipment has been tested and found to comply with the limits for
medical devices in IEC 60601-1:1994. These limits are designed to provide reasonable protection against harmful interference in a typical medical installation.
This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to other devices in the vicinity. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to other devices, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: y Reorient or relocate the receiving device. y Increase the separation between the equipment. y Connect the equipment into an outlet on a circuit different from that to which the other device(s) are connected. y Consult the manufacturer or field service technician for help. y Type of protection against electric shock: Class I equipment y Degree of protection against electric shock: Not classified - no applied parts y Classification according to the degree of protection against ingress of water as detailed in the current edition of IEC 529: IPX0, ordinary equipment y This equipment is not suitable for use in the presence of flammable anesthetics or oxygen y Mode of operation: continuous operation
Class A of CE and FCC certification
The SDIX-100 manufactured by Opticis Co., Ltd., which are all certified by
IEC/EN61000-3, 4 referred in Accession Number 07-1334-0217 as classified in Class A.
1-9 Regulatory Statements
© 2010 Opticis Co., Ltd. All Rights Reserved
Revision 1.0 .Jan. 28, 2010.
Opticis Locations
Headquarters
Opticis Co., Ltd.
#304, Byucksan Technopia, 434-6
Sangdaewon-Dong, Chungwon-Ku,
Sungnam City, Kyungki-Do, 462-716
South Korea
Tel: +82 (31) 737-8033~8
Fax:+82 (31) 737-8079 www.opticis.com
North American Office
Opticis USA LLC
649 Route 206
Unit 9 Suite 307
Hillsborough, NJ 08844
Tel: 908-837-9652
Fax: 908-837-9078 [email protected]
For order support, please contact your Distributor or Reseller.
For technical support, check with the Opticis web site www.opticis.com or contact [email protected]