- Industrial & lab equipment
- Measuring, testing & control
- weintek
- cMT-iV5 Startup Guide
- User manual
- 16 Pages
Weintek cMT-iV5 Startup Guide HMI User Manual
Below you will find brief information for HMI cMT-iV5 Startup Guide. The cMT-iV5 Startup Guide is a 9.7-inch touch panel HMI that provides a user-friendly interface for connecting to cMT-SVR controllers. This guide is designed to help you set up and use the cMT-iV5 with your cMT-SVR system. The cMT-iV5 features a built-in speaker and fan-less cooling system for reliable operation. It supports multiple languages and input methods, making it easy to use in a variety of environments.
advertisement
Assistant Bot
Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.
User
Manual
cMT-iV5 Startup Guide
Table of Contents
cMT-SVR Startup Guide
Chapter1.
Overview
1.1.
Specification
Cloud Human Machine Interface
Features
One Gigabit Ethernet Port
Built-in 512MB Flash Memory
Built-in 1000MB RAM
Fan-less Cooling System
Power Isolator Inside
Built-in mono speaker
Designed for connecting cMT-SVR
Display
Display
Resolution (WxH dots)
Brightness cd/m
2
Contrast Ratio
Backlight Type
Backlight Life Time
Colors
Touch Panel
Type
Accuracy
Storage
Memory
I/O Port
RAM
Processor
Ethernet
Audio Output
Video Input
RTC
Power
Input Power
Power Isolation
Power Consumption
Voltage Resistance
Isolation Resistance
Vibration Endurance
Enclosure
Specification
Dimensions WxHxD
Panel Cutout
Weight
Protection Structure
Storage Temperature
Environment
Operating Temperature
Relative Humidity
Certificate
PCB Coating
Display
Language
Input Methods
9.7” TFT
1024 x 768
350
500:1
LED
>30,000 hrs.
262K
Tempered Glass, Capacitive Type
Active Area Length(X)±2%, Width(Y)±2%
512 MB
1GB
32 bits RISC Cortex-A9 1GHz
10/100/1000M
Built-in Mono Speaker
N/A
Built-in
24±20%VDC
Built-in
900mA@24VDC
500VAC (1 min)
Exceed 50M
at 500VDC
10 to 25Hz(X,Y,Z direction 2G 30 minutes)
Plastic
257.2 x 199.7 x 32.7mm
248.5 x 191 mm
Approx.0.76 kg
NEMA4 / IP65
-20°~60°C (-4° ~ 140°F)
0° ~ 50°C (32° ~ 122°F)
10% ~ 90% @ 40°C (non-condensing)
Yes
CE marked
English, French, Italian, Spanish, Russian, Simplified
Chinese, Traditional Chinese, Korean, Deutsch
English, French, Italian, Spanish, German, Russian, Pinyin,
Zhuyin
V1.00
1
cMT-SVR Startup Guide
1.2.
Dimensions
257.2mm [10.13"]
247.7mm [9.75"]
a a a a a
VESA 75mm screw holes
b
Power Connector
b c
248.5mm [9.78"]
248.5mm [9.78"] W x 191mm [7.52"] H
R16m m
[R0.63"]
c
Ethernet Port
V1.00
2
cMT-SVR Startup Guide
1.3.
Ethernet port
The unit has one 10/100/1000M Gigabit Ethernet port.
The LED indicators on the Ethernet port indicate:
Orange LED: LAN link status
Green LED: Active communication status
To connect Ethernet, please use a CAT-6 Ethernet cable.
1.4.
CR1225 battery
The cMT-iV5 requires a CR1225 coin type lithium battery to keep the RTC running.
Battery type: CR1225 3V lithium battery
1.5.
Power connection
Power:
The unit can be powered by DC power only, voltage range: 24 ± 20% Volts DC, compatible with most controller DC systems. The power conditioning circuitry inside the unit is accomplished by a switching power supply. The peak starting current can be as high as 500mA.
Note:
Connect positive DC line to the
‘
+
’ terminal and the DC ground to the
‘
-
’ terminal.
1.6.
Requirements
1.
CloudHMI: Built-in app for connecting cMT-SVR.
2.
Supported HMI model: cMT-SVR.
3.
One cMT-iV5 can log in and operate three cMT-SVRs simultaneously.
V1.00
3
cMT-SVR Startup Guide
Chapter2.
System Setting
Startup cMT-iV5 and run the built-in CloudHMI app.
Tap the Start Button in the upper-left corner of the screen to open the setting page.
Tapping the checkerboard area returns to the previously used project screen.
2.1.
Information
Tap Setting > Information to view the information about this cMT-iV5.
The information includes: Machine type, HMI name, IP address, Subnet mask, Gateway, Mac address, App. version, and OS. version.
V1.00
4
cMT-SVR Startup Guide
2.2.
General
In General tab, screen brightness and audio volume can be adjusted, and password can be changed.
After entering the password, the HMI name can be viewed and changed. Tap the Direction icon to change the display direction.
2.3.
Language
In Language tab, select an interface language. The options are: English, French, Italian, Spanish,
Russian, Simplified Chinese, Traditional Chinese, Korean, and German.
2.4.
Input Method
Add in keyboards of different languages. The options are: English, French, Italian, Spanish, Russian,
Simplified Chinese (Pinyin), Traditional Chinese (Zhuyin), and German.
Tap icon in the upper-left corner (a cMT-iV5 password is required). Enter the password and
V1.00
5
click OK, the Time/Date and Network setting tabs will be enabled.
2.5.
Time/Date
In Time/Date tab, set the current system time and date.
cMT-SVR Startup Guide
2.6.
Network
In Network tab, enable [Obtain an IP address automatically] or manually enter IP address, Subnet mask, Gateway, and DNS.
2.7.
cMT-SVR System Setting
The system information of cMT-SVR can be set from CloudHMI in cMT-iV5. Tap Search, find the
V1.00
6
cMT-SVR Startup Guide cMT-SVR and tap to open cMT-SVR setting page.
See cMT-SVR User Manual for more information: http://www.weintek.com/Download/cMT/eng/UserManual/cMT_SVR_UserManual_eng.pdf
V1.00
7
cMT-SVR Startup Guide
Chapter3.
CloudHMI App
3.1.
Introduction of icons
Icon Description
When running CloudHMI, tap the Start Button to configure the settings.
Project tab lists the logged in cMT-SVRs. Each cMT-iV5 can control three cMT-SVRs simultaneously.
Search tab lists all the cMT-SVRs on the same network.
History tab lists the cMT-SVRs previously logged in.
System tab is used to adjust the brightness and volume, or view information.
Tap this icon to make cMT-SVR CPU LED (green) blink for identify the cMT-SVR.
Tap this icon to load cMT-SVR project to cMT-iV5 and run the project.
Tap this icon to configure cMT-SVR system settings.
In Search tab, sort cMT-SVRs according to IP address.
In Search tab, sort cMT-SVRs according to HMI name.
In History tab, clear all the login records.
Tap this icon to understand more information about the features and operations.
V1.00
8
3.2.
How to load project file to cMT-iV5
Step 1.
Run cMT-iV5, tap Start Button as shown in the following figure. cMT-SVR Startup Guide
Step 2.
Search all the cMT-SVRs on the same network.
Step 3.
Select the cMT-SVR, tap
V1.00
and then enter password.
9
cMT-SVR Startup Guide
Step 4.
The cMT-iV5 displays the project after the project is loaded
Tap Start Button to return to Search screen. To connect another cMT-SVR, repeat the preceding process to search for cMT-SVR and then load the project.
V1.00
10
cMT-SVR Startup Guide
The badge is displayed in the icons of the successfully connected cMT-SVRs.
One cMT-iV5 can login to up to three cMT-SVRs simultaneously. Once the limit has been reached the buttons for other cMT-SVRs will be unavailable and grayed out.
3.3.
How to switch between cMT-SVR projects
When multiple cMT-SVRs are connected, to switch between cMT-SVR projects, select from Project tab. To delete a project of a connected cMT-SVR, tap .
V1.00
11
cMT-SVR Startup Guide
Chapter4.
Updating Firmware, OS
CloudHMI (also called firmware) and OS version on cMT-iV5 can be updated via Ethernet.
Launch Utility Manager, select cMT Series, and click [Maintenance] > [iV5 upgrade] to run the iV5 upgrade program.
4.1.
Updating CloudHMI
Step 1.
Place the CloudHmi.iv5 file into the firmware folder under the EasyBuilder Pro installation directory. (The default directory: ebpro/firmware)
Step 2.
In the iV5 upgrade program select the HMI IP and select [Firmware]. The firmware will be downloaded and upgraded to cMT-iV5.
V1.00
12
cMT-SVR Startup Guide
Step 3.
Upon completion the updated CloudHMI version can be found in the Setting > Information tab.
4.2.
Updating OS
Please note that OS upgrade is a critical operation. Please make sure power stays on and do not disconnect before the update is completed.
Step 1.
In the iV5 upgrade program select the HMI IP and select [OS]. A warning message is displayed, select [Start Firmware Upgrade] check box and click OK.
Step 2.
Browse for the directory of the OS file named MTFirmware_iV5.bin, and click [Update].
V1.00
13
cMT-SVR Startup Guide
Step 3.
A confirmation message is displayed. Click [Yes] and the OS will be downloaded and upgraded to cMT-iV5.
Step 4.
Upon completion the updated OS version can be found in the Setting > Information tab.
V1.00
14
advertisement
Key Features
- 9.7-inch touch panel
- Built-in speaker
- Fan-less cooling system
- Supports multiple languages
- Supports multiple input methods
- Designed for connecting cMT-SVR
Frequently Answers and Questions
How do I connect the cMT-iV5 to a cMT-SVR?
How do I update the firmware and OS on the cMT-iV5?
What are the system requirements for the cMT-iV5?
Related manuals
advertisement
Table of contents
- 3 Overview
- 3 Specification
- 4 Dimensions
- 5 Ethernet port
- 5 CR1225 battery
- 5 Power connection
- 5 Requirements
- 6 System Setting
- 6 Information
- 7 General
- 7 Language
- 7 Input Method
- 8 Time/Date
- 8 Network
- 8 cMT-SVR System Setting
- 10 CloudHMI App
- 10 Introduction of icons
- 11 How to load project file to cMT-iV
- 13 How to switch between cMT-SVR projects
- 14 Updating Firmware, OS
- 14 Updating CloudHMI
- 15 Updating OS