Weintek cMT-iV5 Startup Guide HMI User Manual

Weintek cMT-iV5 Startup Guide HMI User Manual
Add to My manuals

Below you will find brief information for HMI cMT-iV5 Startup Guide. The cMT-iV5 Startup Guide is a 9.7-inch touch panel HMI that provides a user-friendly interface for connecting to cMT-SVR controllers. This guide is designed to help you set up and use the cMT-iV5 with your cMT-SVR system. The cMT-iV5 features a built-in speaker and fan-less cooling system for reliable operation. It supports multiple languages and input methods, making it easy to use in a variety of environments.

advertisement

Assistant Bot

Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.

Weintek cMT-iV5 Startup Guide - User Manual | Manualzz

User

Manual

cMT-iV5 Startup Guide

Table of Contents

Chapter1.

Overview ........................................................................................................................................ 1

1.1.

Specification ....................................................................................................................................... 1

1.2.

Dimensions ......................................................................................................................................... 2

1.3.

Ethernet port ...................................................................................................................................... 3

1.4.

CR1225 battery .................................................................................................................................. 3

1.5.

Power connection .............................................................................................................................. 3

1.6.

Requirements ..................................................................................................................................... 3

Chapter2.

System Setting ............................................................................................................................... 4

2.1.

Information ........................................................................................................................................ 4

2.2.

General ............................................................................................................................................... 5

2.3.

Language ............................................................................................................................................ 5

2.4.

Input Method ..................................................................................................................................... 5

2.5.

Time/Date .......................................................................................................................................... 6

2.6.

Network.............................................................................................................................................. 6

2.7.

cMT-SVR System Setting .................................................................................................................... 6

Chapter3.

CloudHMI App ................................................................................................................................ 8

3.1.

Introduction of icons .......................................................................................................................... 8

3.2.

How to load project file to cMT-iV5 ................................................................................................... 9

3.3.

How to switch between cMT-SVR projects ...................................................................................... 11

Chapter4.

Updating Firmware, OS ................................................................................................................ 12

4.1.

Updating CloudHMI .......................................................................................................................... 12

4.2.

Updating OS ..................................................................................................................................... 13

cMT-SVR Startup Guide

Chapter1.

Overview

1.1.

Specification

Cloud Human Machine Interface

Features

One Gigabit Ethernet Port

Built-in 512MB Flash Memory

Built-in 1000MB RAM

Fan-less Cooling System

Power Isolator Inside

Built-in mono speaker

Designed for connecting cMT-SVR

Display

Display

Resolution (WxH dots)

Brightness cd/m

2

Contrast Ratio

Backlight Type

Backlight Life Time

Colors

Touch Panel

Type

Accuracy

Storage

Memory

I/O Port

RAM

Processor

Ethernet

Audio Output

Video Input

RTC

Power

Input Power

Power Isolation

Power Consumption

Voltage Resistance

Isolation Resistance

Vibration Endurance

Enclosure

Specification

Dimensions WxHxD

Panel Cutout

Weight

Protection Structure

Storage Temperature

Environment

Operating Temperature

Relative Humidity

Certificate

PCB Coating

Display

Language

Input Methods

9.7” TFT

1024 x 768

350

500:1

LED

>30,000 hrs.

262K

Tempered Glass, Capacitive Type

Active Area Length(X)±2%, Width(Y)±2%

512 MB

1GB

32 bits RISC Cortex-A9 1GHz

10/100/1000M

Built-in Mono Speaker

N/A

Built-in

24±20%VDC

Built-in

900mA@24VDC

500VAC (1 min)

Exceed 50M

at 500VDC

10 to 25Hz(X,Y,Z direction 2G 30 minutes)

Plastic

257.2 x 199.7 x 32.7mm

248.5 x 191 mm

Approx.0.76 kg

NEMA4 / IP65

-20°~60°C (-4° ~ 140°F)

0° ~ 50°C (32° ~ 122°F)

10% ~ 90% @ 40°C (non-condensing)

Yes

CE marked

English, French, Italian, Spanish, Russian, Simplified

Chinese, Traditional Chinese, Korean, Deutsch

English, French, Italian, Spanish, German, Russian, Pinyin,

Zhuyin

V1.00

1

cMT-SVR Startup Guide

1.2.

Dimensions

257.2mm [10.13"]

247.7mm [9.75"]

a a a a a

VESA 75mm screw holes

b

Power Connector

b c

248.5mm [9.78"]

248.5mm [9.78"] W x 191mm [7.52"] H

R16m m

[R0.63"]

c

Ethernet Port

V1.00

2

cMT-SVR Startup Guide

1.3.

Ethernet port

The unit has one 10/100/1000M Gigabit Ethernet port.

The LED indicators on the Ethernet port indicate:

Orange LED: LAN link status

Green LED: Active communication status

To connect Ethernet, please use a CAT-6 Ethernet cable.

1.4.

CR1225 battery

The cMT-iV5 requires a CR1225 coin type lithium battery to keep the RTC running.

Battery type: CR1225 3V lithium battery

1.5.

Power connection

Power:

The unit can be powered by DC power only, voltage range: 24 ± 20% Volts DC, compatible with most controller DC systems. The power conditioning circuitry inside the unit is accomplished by a switching power supply. The peak starting current can be as high as 500mA.

Note:

Connect positive DC line to the

+

’ terminal and the DC ground to the

-

’ terminal.

1.6.

Requirements

1.

CloudHMI: Built-in app for connecting cMT-SVR.

2.

Supported HMI model: cMT-SVR.

3.

One cMT-iV5 can log in and operate three cMT-SVRs simultaneously.

V1.00

3

cMT-SVR Startup Guide

Chapter2.

System Setting

Startup cMT-iV5 and run the built-in CloudHMI app.

Tap the Start Button in the upper-left corner of the screen to open the setting page.

Tapping the checkerboard area returns to the previously used project screen.

2.1.

Information

Tap Setting > Information to view the information about this cMT-iV5.

The information includes: Machine type, HMI name, IP address, Subnet mask, Gateway, Mac address, App. version, and OS. version.

V1.00

4

cMT-SVR Startup Guide

2.2.

General

In General tab, screen brightness and audio volume can be adjusted, and password can be changed.

After entering the password, the HMI name can be viewed and changed. Tap the Direction icon to change the display direction.

2.3.

Language

In Language tab, select an interface language. The options are: English, French, Italian, Spanish,

Russian, Simplified Chinese, Traditional Chinese, Korean, and German.

2.4.

Input Method

Add in keyboards of different languages. The options are: English, French, Italian, Spanish, Russian,

Simplified Chinese (Pinyin), Traditional Chinese (Zhuyin), and German.

Tap icon in the upper-left corner (a cMT-iV5 password is required). Enter the password and

V1.00

5

click OK, the Time/Date and Network setting tabs will be enabled.

2.5.

Time/Date

In Time/Date tab, set the current system time and date.

cMT-SVR Startup Guide

2.6.

Network

In Network tab, enable [Obtain an IP address automatically] or manually enter IP address, Subnet mask, Gateway, and DNS.

2.7.

cMT-SVR System Setting

The system information of cMT-SVR can be set from CloudHMI in cMT-iV5. Tap Search, find the

V1.00

6

cMT-SVR Startup Guide cMT-SVR and tap to open cMT-SVR setting page.

See cMT-SVR User Manual for more information: http://www.weintek.com/Download/cMT/eng/UserManual/cMT_SVR_UserManual_eng.pdf

V1.00

7

cMT-SVR Startup Guide

Chapter3.

CloudHMI App

3.1.

Introduction of icons

Icon Description

When running CloudHMI, tap the Start Button to configure the settings.

Project tab lists the logged in cMT-SVRs. Each cMT-iV5 can control three cMT-SVRs simultaneously.

Search tab lists all the cMT-SVRs on the same network.

History tab lists the cMT-SVRs previously logged in.

System tab is used to adjust the brightness and volume, or view information.

Tap this icon to make cMT-SVR CPU LED (green) blink for identify the cMT-SVR.

Tap this icon to load cMT-SVR project to cMT-iV5 and run the project.

Tap this icon to configure cMT-SVR system settings.

In Search tab, sort cMT-SVRs according to IP address.

In Search tab, sort cMT-SVRs according to HMI name.

In History tab, clear all the login records.

Tap this icon to understand more information about the features and operations.

V1.00

8

3.2.

How to load project file to cMT-iV5

Step 1.

Run cMT-iV5, tap Start Button as shown in the following figure. cMT-SVR Startup Guide

Step 2.

Search all the cMT-SVRs on the same network.

Step 3.

Select the cMT-SVR, tap

V1.00

and then enter password.

9

cMT-SVR Startup Guide

Step 4.

The cMT-iV5 displays the project after the project is loaded

Tap Start Button to return to Search screen. To connect another cMT-SVR, repeat the preceding process to search for cMT-SVR and then load the project.

V1.00

10

cMT-SVR Startup Guide

The badge is displayed in the icons of the successfully connected cMT-SVRs.

One cMT-iV5 can login to up to three cMT-SVRs simultaneously. Once the limit has been reached the buttons for other cMT-SVRs will be unavailable and grayed out.

3.3.

How to switch between cMT-SVR projects

When multiple cMT-SVRs are connected, to switch between cMT-SVR projects, select from Project tab. To delete a project of a connected cMT-SVR, tap .

V1.00

11

cMT-SVR Startup Guide

Chapter4.

Updating Firmware, OS

CloudHMI (also called firmware) and OS version on cMT-iV5 can be updated via Ethernet.

Launch Utility Manager, select cMT Series, and click [Maintenance] > [iV5 upgrade] to run the iV5 upgrade program.

4.1.

Updating CloudHMI

Step 1.

Place the CloudHmi.iv5 file into the firmware folder under the EasyBuilder Pro installation directory. (The default directory: ebpro/firmware)

Step 2.

In the iV5 upgrade program select the HMI IP and select [Firmware]. The firmware will be downloaded and upgraded to cMT-iV5.

V1.00

12

cMT-SVR Startup Guide

Step 3.

Upon completion the updated CloudHMI version can be found in the Setting > Information tab.

4.2.

Updating OS

Please note that OS upgrade is a critical operation. Please make sure power stays on and do not disconnect before the update is completed.

Step 1.

In the iV5 upgrade program select the HMI IP and select [OS]. A warning message is displayed, select [Start Firmware Upgrade] check box and click OK.

Step 2.

Browse for the directory of the OS file named MTFirmware_iV5.bin, and click [Update].

V1.00

13

cMT-SVR Startup Guide

Step 3.

A confirmation message is displayed. Click [Yes] and the OS will be downloaded and upgraded to cMT-iV5.

Step 4.

Upon completion the updated OS version can be found in the Setting > Information tab.

V1.00

14

advertisement

Key Features

  • 9.7-inch touch panel
  • Built-in speaker
  • Fan-less cooling system
  • Supports multiple languages
  • Supports multiple input methods
  • Designed for connecting cMT-SVR

Frequently Answers and Questions

How do I connect the cMT-iV5 to a cMT-SVR?
The cMT-iV5 is designed for connecting to cMT-SVR controllers. Use a CAT-6 Ethernet cable to connect the cMT-iV5 to the cMT-SVR.
How do I update the firmware and OS on the cMT-iV5?
You can update the firmware and OS on the cMT-iV5 via Ethernet using the Utility Manager. Launch Utility Manager, select cMT Series, and click [Maintenance] > [iV5 upgrade] to run the iV5 upgrade program. You will need to have the necessary firmware and OS files available.
What are the system requirements for the cMT-iV5?
The cMT-iV5 requires a CR1225 coin type lithium battery to keep the RTC running. The unit can be powered by DC power only, voltage range: 24±20% Volts DC, compatible with most controller DC systems. The power conditioning circuitry inside the unit is accomplished by a switching power supply. The peak starting current can be as high as 500mA.

Related manuals