VDS 2510 2510-R, 2510-L transmission system Installation Manual
The VDS2510 2510-R and VDS2510 2510-L are a transmission system for sending two video, two audio, two alarm signals and DC power through one coaxial cable. It can transmit signals and 12VDC power up to 800 meters, or up to 1,000 meters if a camera is powered at the remote end. The system is easy to install and use, and requires only one cable to connect all components.
advertisement
Assistant Bot
Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.
VDS2510 Installation Manual
Video Signal Output No. 1
C
C
N.O.
N.C.
Alarm
Output
Ground
Audio Out
N.O.
Alarm
Output
N.C.
Ground
Audio Out
Video Signal Output No. 2
OUTPUT Connections
There are two VIDEO OUT connectors. Please connect each connector with a cable to a device, e.g. a monitor.
There are two Audio OUT connectors.
Please connect each connector with a cable to a device, e.g. a monitor or a speaker.
There are two ALARM OUT connectors. Please link the N.C. N.O.
connect from each of the ALARM OUT connectors to other further application devices.
Distributor/Retailer
Copyright (c) 2006,
All Rights Reserved.
Foresight CCTV , Inc.
Email: info@ oresight -cctv .com
Made in Taiwan
047ab, May. 2006
VDS2510 Installation Manual
VDS2510
Installation Manual
Viewer
2510-L (Local Unit)
Sender
2510-R (Remote Unit)
Content
Introduction .........................................................2
Features .............................................................2
Packing Checklist....................................................2
Certificate ..........................................................2
Patents ..............................................................2
Limited Warranty .....................................................2
Specification of VDS2510-R Sender ...................................3
Specification of VDS2510-L Viewer ...................................3
Functions of Remote Unit(VDS2510-R Sender) ..........................4
Functions of Local Unit(VDS2510-L Viewer) ...........................5
Installation of Remote Unit and Local Unit ..........................6
Making Connection....................................................8
Installation Notice..................................................8
Connecting Sender Unit...............................................9
Connecting Viewer Unit .............................................11
www.foresight-cctv.com
047ab, May. 2006
VDS2510 Installation Manual
Introduction
The VDS2510 series is a transmission system for sending two video, two audio, two alarm signals and DC power through one coaxial cable.
The system can transmit signals and 12VDC power up to 800 meters. If a camera is powered at the remote end, without DC power supplying from Viewer, the transmission distance of the VDS2510 can reach 1,000 meters.
Features
&
&
&
One cable transmits all signals and DC power.
Universal Voltage Input (85V~265V).
Up to 800 meters transmission range while sending DC power from the Viewer unit; up to 1,000 meters transmission range when cameras have another power source.
&
Real time analog video signals for color and B/W (50fps/60fps), better than
480TVL resolution.
&
Built-in electrical transient voltage suppressor (TVS) protection, gas tube arrester protection and lightning protection
&
&
Inter-carrier technology eliminates signal interference.
Accept both N.C. or N.O. alarm connection, or mix of N.C. and N.O. In Term mode.
Packing Checklist
Carefully unpack the VDS2510 and check that the following items are included:
&
&
&
&
&
&
VDS2510-R Sender (Remote Unit)
VDS2510-L Viewer (Local Unit)
Power supply (AC to DC power adapter) and power cord
Four mounting brackets and four screws
Two 1,000 ohms terminators for alarm mode use in Alarm Input side.
Installation Manual
Contact your dealer immediately if any of the above items appears damaged or the unit does not work.
Certificate
This equipment has been tested and found to comply with the Part 15 rules of the US FCC Regulation, and gets CE approved.
Patents
Patents covering the design, operation, techniques, and unique features of the Single-cable transmission device of a surveillance system include: U.S. Patent #US 6,369,699 B1 April 9, 2002; Taiwan
Patent #201389 September 3 2004; Europe Patent #EP 1134909 A1
September 19, 2001.
Other Patents are pending.
Limited Warranty
Foresight grants a warranty for this product for 18 months.
Please offer the purchase date and the serial Number of Bar-Code on the back of the product to your distributor or retailer as proof for this purpose . During the warranty period, in case of defected in material or workmanship, the defective unit will be repaired or replaced according to the assessment of Foresight.
However, this warranty does not cover damages caused by improper use or from unauthorized modifications by third parties.
- 2 -
047ab, May. 2006
VDS2510 Installation Manual
Connecting Viewer unit
The following illustration shows the connections for the Viewer unit:
Link In
DC power can be sent to the
Remote side for cameras power consumption.
Link Fault Indication
System Status
DC40V
DC Power Input
LINK IN Connections
Connect the other end of the coaxial cable which is connected to the LINK OUT side of the Sender unit to the LINK IN side of the
Viewer unit.
Connect a wire from the +12V pin and Out of the LINK FAULT PTB connector to a buzzer or an indicator wherever you want.
Plug the power cord on and connect the AC to DC power adapter to the DC POWER IN connector in the LINK IN side of the Viewer unit.
- 11 -
047ab, May. 2006
VDS2510 Installation Manual
Link Out
Power Status
Alarm
Input
Type
Selector
LED here can indicate the
Alarm connecting
Coaxial cable is used for Link Out to send broadband signals: 2 video, 2
Audio and 2 alarm signals.
Coaxial Cable
1 to 800Metres use RG-6/u or Equivalents
LINK OUT Connection
Connect the LINK OUT of Sender unit with one end of a coaxial cable, and connect the other end of the coaxial cable to the LINKIN side of
VDS2510 Installation Manual
Specification of VDS2510-R Sender
To ensure smooth operation of VDS2510, the following minimum system and setup requirements should be met.
Electrical:
All video, Audio and Alarm have two inputs
Video Input Signal: 1.0Vpp, 75 ohms
Bandwidth of Video Signal: 5.5MHz typ.
Audio Input Signal: 3.0Vpp, 100K ohms, max
Alarm Input type: N.C./N.O./Terminal 1,000 ohms
Power Output: DC12V, 1.0 A(2 cameras in total), max.
Connection
:
(PTB= Plugable Terminal Block)
Video Input: BNC Socket X 2
Audio Input, Alarm Input and DC Out: 5 Pin PTB X 2, 3.5mm Pitch
Link Out: BNC Socket
Specification of VDS2510-L Viewer
Electrical:
All video, Audio and Alarm have two outputs
Video Output Signal: 1.0Vpp, 75 ohms
Bandwidth of Video Signal: 5.5MHz typ.
S/N ratio of Video Signal: 50dB typ.
Gain of Audio signal Output: 0dB ∮3dB, 600 ohms / internal impedance
Bandwidth of Audio Signal: 50Hz to 10KHz ∮3dB
S/N Ratio of Audio Signal: 46dB under 1.0Vpp input at RU
Alarm Output: N.C./N.O., Contact Rating 1A, 30VDC Dry contact
DC Power Input: 40V
Max. DC power Output: 38V, 1.6A, min.
Link Fault Output : 0.15A, min.
Connection
:
(PTB= Plugable Terminal Block)
Link In: BNC Socket
Link Fault: 2 Pin PTB, 3.5mm Pitch
DC Power Input: 2 Pin PTB, 5.0mm Pitch
Video Output: BNC Socket X 2
Audio Output and Alarm Output: 5 Pin PTB X 2, 3.5mm Pitch
- 10 -
047ab, May. 2006
- 3 -
047ab, May. 2006
VDS2510 Installation Manual
Functions of Remote Unit
VDS2510-R Sender
INPUT side
VIDEO IN: to receive a video signal from video source, eg. a camera.
AUDIO IN: to receive an audio signal from an audio source, eg. a microphone.
ALARM IN: to receive alarm connection from devices like sensors or infra-red detective devices. Both N.O. and N.C. are acceptable, even at the same time(under the TERM).
DC OUT: to send 12VDC power to cameras.
LINK OUT Side
LINK OUT with DC IN: to send out two video, two audio, two alarm signals to the Viewer unit and to receive DC power from the Viewer unit.
POWER STATUS LED: to indicate the power supplying condition. When LED is red, it implies the power supplying to camera is stand-by or not been used.
When LED is green, it means the power is loaded well to the camera.
When LED is Yellow, it means the DC power is low. Please check if the cable used is over length limitation or the DC consumption of the two cameras in total is more than 1.0A (note1). When LED is flashing, it implies the power supply might be failed due to the power is too low to offer any function.
ALARM
LED: to indicate the Alarm Input and Alarm Output are both well working.
CONNECTION INPUT TYPE: to let users to select which alarm connection type to apply: N.C.
or N.O. or TERM (mixed with N.O. and N.C.)
Note 1. The 1.0A is based on the condition of less than 600M distances and 5C-2V coaxial cable used.
Please refer to How to Use Alarm manual enclosed.
- 4 -
047ab, May. 2006
VDS2510 Installation Manual
Connecting Sender unit
The following illustration shows the connections for the Sender
Video Signal Input
Audio Signal In
Ground
Alarm Sensor In
DC 12V Out
Audio Signal In
Ground
Alarm Sensor In
DC 12V Out
Video Signal Input
No. 1
No. 2
INPUT Connection
There are two VIDEO IN connectors. Please connect each VIDEO IN connector with one end of a cable carrying video signal from the video source.
There are two AUDIO IN connectors. Please connect each AUDIO IN connector with one end of a cable carrying audio signal from the audio source.
There are two ALARM IN connectors. Please connect each PTB connector in ALARM IN with a wire with the N.O./N.C. connection from sensors.
Please refer to How to Use Alarm manual to improve security and flexibility of alarm connection.
There are two DC OUT connectors. Please connect each DC OUT connectors with the power cord (DC 12V) to the video source, e.g. a camera.
- 9 -
047ab, May. 2006
VDS2510 Installation Manual
Making Connection
The following illustration gives an overview of the Sender unit and the Viewer unit connections.
VDS2510 Installation Manual
Functions of Local Unit
VDS2510-L Viewer
L I N K I N s i d e
LINK IN with DC OUT: to receive in two video, two audio, and two alarm signals from the
Sender unit and also to send DC power out to the Sender unit.
LINK FAULT: to warn users if the cable between Sender unit and Viewer unit is disconnected.
To allow users to send the warning signal to an extra warning device, e.g. buzzer, relay or light bulb and everyplace users prefer.
SYSTEM STATUS LED:
When users turn off the system, LED will be red. When users turn on the system, LED will be yellow at the first 5 seconds for initial, and then become green. The LED will keep green, when the system is on.
ON/OFF: to turn on or turn off the system
DC POWER IN: to input the power from the power supply.
OUTPUT side
VIDEO OUT: to send the video signals out to a device, e.g. A monitor or DVR
AUDIO OUT: to send out the audio signals to a device, e.g. monitor or loudspeaker amplifier. The audio signal level output from the AUDIO
OUT is exactly the same as what the AUDIO IN received at Sender
Unit .
ALARM OUT: to send the alarm connection out for a further application.
LED:
To indicate the alarm function is operating.
Power Supply
Installation Notice
When setting up the VDS2510 Sender unit and Viewer unit, be sure to note the following points:
Both units should be fixed securely to a permanent object such as a wall or a pillar.
Avoid locations with extreme vibrations or dust.
Avoid locations with dampness or extreme heat.
- 8 -
047ab, May. 2006 047ab, May. 2006
VDS2510 Installation Manual
I n s t a l l a t i o n o f R e m o t e a n d L o c a l U n i t s
T h e V D S 2 5 1 0 u n i t s c a n b o t h b e f i x e d t o a w a l l o r d e s k t o p w i t h t h e s u p p l i e d m o u n t i n g b r a c k e t s . T h e m o u n t i n g b r a c k e t s c a n b e f i x e d o n t o t h e r e a r , t o p , o r b o t t o m o f e i t h e r u n i t .
A t t a c h i n g t h e M o u n t i n g B r a c k e t s
A t t a c h t h e m o u n t i n g b r a c k e t s t o e i t h e r t h e S e n d e r u n i t o r t h e v i e w e r u n i t a s s h o w n b e l o w :
1 . A l i g n t h e m o u n t i n g b r a c k e t w i t h t h e m o u n t i n g t r a c k o n t h e r e a r o f t h e u n i t a s s h o w n h e r e :
Mounting
Tracks
2 . S l i d e t h e b r a c k e t i n t h e d i r e c t i o n o f t h e a r r o w u n t i l t h e w h i t e n u b c l i c k s i n t o p l a c e a s s h o w n b e l o w :
Nub
VDS2510 Installation Manual
4. Fix the unit in the desired location with two screws.
Removing the Mounting Brackets
Remove the mounting as shown below:
1. Use a flat-tipped screwdriver to lift the white nub as shown below:
Nub
2 . W h i l e l i f t i n g t h e n u b , s l i d e t h e b r a c k e t o u t i n t h e d i r e c t i o n o f t h e a r r o w a s s h o w n b e l o w :
3 . R e p e a t t h e a b o v e s t e p s o n a n o t h e r s i d e o f t h e u n i t t o a t t a c h t h e s e c o n d b r a c k e t .
- 6 -
047ab, May. 2006
3 . R e p e a t t h e a b o v e s t e p s t o r e m o v e t h e s e c o n d b r a c k e t .
- 7 -
047ab, May. 2006
advertisement
Key Features
- One cable transmits all signals and DC power
- Universal Voltage Input (85V~265V)
- Up to 800 meters transmission range
- Real time analog video signals
- Built-in electrical transient voltage suppressor
- Inter-carrier technology eliminates signal interference
- Accept both N.C. or N.O. alarm connection
Frequently Answers and Questions
What is the maximum transmission distance of the VDS2510?
What type of coaxial cable should I use with the VDS2510?
Can I use both N.C. and N.O. alarm connections?
What are the alarm input types?
What is the maximum DC power output?
Related manuals
advertisement
Table of contents
- 2 Introduction
- 2 Features
- 2 Packing Checklist
- 2 Certificate
- 2 Patents
- 2 Limited Warranty
- 3 Specification of VDS2510-R Sender
- 3 Specification of VDS2510-L Viewer
- 4 Functions of Remote Unit(VDS2510-R Sender)
- 5 Functions of Local Unit(VDS2510-L Viewer)
- 6 Installation of Remote Unit and Local Unit
- 5 Making Connection
- 5 Installation Notice