UNIVERSAL PORTABLE CALIBRATOR v Modes : Measure and Source (Calibrate) v B, E, J, K, R, S, T, W1, W3 & W5 thermocouples and Pt100 RTD measure in °C or °F, and simulate in °C or °F v Millivolts (-199.99 to +199.99) and milliamps (0 to 19999 microamps) v High accuracy : ± 0.02% of FS ± 2 counts (except ohms) MICROCAL v v v v v v v High resolution : 0.1 °C or °F, 10 µV, 1 µA, 0.02 W 2x16 character dot-matrix LCD display Membrane keypad Ni-cad batteries for 4 to 8 hours operation on single charge Compact : 220x80x220 mm Lightweight : 1.5 kg Available with NPL traceable internal or 3rd party certificate GENERAL FUNCTIONS MICROCAL is a precision thermometer/calibrator for measurement of process signals and calibration of process instrumentation. Temperature Measurement It can : Measure/Source millivolts (0 to ±199.99 mV) Measure/Calibrate in °C/°F (-270 °C to +1820°C, -454 °F to +3308°F) Measure/Source milliamps (0 to 19999 µA) MICROCAL is a state-of-the-art instrument featuring a microprocessor based closed loop design. This means that the programmed output is continuously compared with a highly stable reference, and automatically corrected for any errors. Thus the accuracy achieved is extremely high : typically, better than ±0.02% of FS. Further, use of the microcomputer allows direct display in °C/°F of thermocouple and RTD inputs, as well as automatic and manual cold-junction compensation for thermocouples. The use of membrane keypad for function selection and setting instead of mechanical push button switches greatly enhances reliability. In this mode the instrument displays the linearised temperature of the thermocouple or RTD sensor on the display. The units can be °C or °F. For thermocouples, the cold junction temperature can be automatically corrected for, or set manually. Millivolts Measurement The measured millivolts of a thermocouple or any source can be displayed directly. Calibration in °C/°F In this mode MICROCAL generates the emf corresponding to any required temperature for the selected thermocouple. This can be referenced to any cold junction temperature manually. It can also be automatically compensated. Millivolts Source The required millivolts (-199.99 to 199.99 mV) are directly sourced. Milliamps Measurement C1014\LEAFLET\MICROCAL.CDR\R4\P1\2 CALIBRATION CERTIFICATE MICROCAL is supplied with a detailed internal calibration certificate with traceability to national/international standards. This is supplied free of charge. If a third party calibration certificate is required, it can be supplied at extra cost. Please provide a minimum additional time of 2 months for this. The instrument measures and displays the milliamp input (0 to 19999 µA). Milliamps Source The instrument fuctions as a powered transmitter generating any set current value (0 to 19999 µA) into a load of upto 500 W. UNIVERSAL PORTABLE CALIBRATOR MICROCAL TABLE 1 LINEARITY ERROR (°C) RANGE (°F) LINEARITY ERROR (°F) RESOLUTION (°F) 0.2 -346 to 1400 0.5 0.4 0.25 0.25 -454 to 2501 0.5 0.5 -270 to 400 0.1 0.2 -454 to 752 0.2 0.4 -271 to 1000 0.25 0.2 -454 to 1832 0.5 0.4 0 to 1768 0.25 0.8 32 to 3214 0.5 1.6 0 to 1768 0.25 0.8 32 to 3214 0.5 1.6 B Pt-6% Rh/Pt-30% Rh 400 to 1820 0.5 0.8 752 to 3308 1.0 1.6 W1 0 to 2320 1.0 1.0 32 to 4200 2.0 2.0 W3 Tungsten-3% Rhenium/ Tungsten-25% Rhenium 0 to 2320 1.0 1.0 32 to 4200 2.0 2.0 W5 0 to 2320 1.0 1.0 32 to 4200 2.0 2.0 -150 to 600 0.25 0.1 -240 to 1110 0.5 0.2 THERMOCOUPLE TYPE RANGE (°C) J -210 to 760 0.25 -270 to 1372 T Cu/Constantan E RESOLUTION (°C) Fe/Constantan K Chromel/Alumel Chromel/Constantan R Pt-13% Rh/Pt S Pt-10% Rh/Pt Tungsten/ Tungsten-26% Rhenium Tungsten-5% Rhenium/ Tungsten-26% Rhenium Pt100, 3-wire RTD v J, K, T, E, R, S, B conform to BS 4927, IEC 584-1 and ASTME 230. W1, W3, W5 conform to tables provided by Hoskins Manufacturing Company. Pt100 conforms to DIN 43760. TABLE 2 FUNCTION TABLE 3 RANGE ACCURACY RESOLUTION mV -199.99 to 199.99 mV 10 Microvolts Thermocouple, Millivolt ±60 µV mA 0 to 19999 µA 1 Microampere Milliamps ±6 µA Pt100 0 to 400.00 W 0.02 Ohms Pt100, 3-wire RTD ±0.5 W Resolution Accuracy Temperature coefficient of accuracy Maximum output current (mV/°C/°F source modes) Maximum burden (mA source mode) Operating temperature Humidity Batteries Battery life Battery charger Dimensions (in mm) Weight See Tables 1 & 2 See Table 3 0.004%/°C SPECIFICATIONS Display Error messages Display update rate Warm-up time Modes C1014\LEAFLET\MICROCAL.CDR\R4\P2\2 Ranges 2x16 character dot-matrix LCD display Display flashes messages to indicate conditions such overrange, underrange, incorrect key operations, etc. 2 readings/second Less than one minute a) Millivolts Measure b) Millivolts Source c) °C/°F Measure d) °C/°F Source e) Milliamps Measure f) Milliamps Source See Tables 1 & 2 Radix Electrosystems Pvt Ltd B-14, 2nd Floor, Ghanshyam Indl Estate Veera Desai Road, Andheri (West) Mumbai - 400 053, India Tel : + 91 22 26730101 · Fax : + 91 22 26731891 Email : [email protected] · www.radix.co.in BANGALORE BARODA CHENNAI HYDERABAD NAGPUR NEW DELHI PUNE 0.5 mA below 60 mV 0.3 mA above 60 mV 500 W 0 to 40 °C 0 to 80% RH, non condensing 1.2V x 8 size R6 Ni-Cad cells 4 to 8 hours per charge Included 220(W)x80(H)x220(D) 1.6 kg (ohms module 0.35 kg) Tel : 25286211, Fax : 25342931 Telefax : 2491749 Tel : 28293345, Fax : 28290341 Tel : 27898403/27818386, Fax : 27819327 Tel : 2551318/19/20, Fax : 2551914 Tel : 25786350, Fax : 2576 2094 Tel : 24479759, Fax : 24482796
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
advertisement