KaDe KZ-500 U/H Access controller Installation Manual

KaDe KZ-500 U/H Access controller Installation Manual

Below you will find brief information for Access controller KZ-500 U/H. The KZ-500 U/H access controller is a waterproof, standalone device that can be used for door access control. It supports up to 10,000 cards, can read both 125KHZ HID and 125KHZ EM cards, and features remote control programming, manager cards for adding and deleting users, block enrollment, and anti-passback functionality. The KZ-500 U/H offers Wiegand 26 input/output, can be used as a slave reader or controller, and can be interconnected with another KZ-500 unit for a single door application. It is a reliable and versatile control system for various security applications.

advertisement

Assistant Bot

Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.

Access controller KZ-500 U/H Installation Manual | Manualzz

Installation Manual

INTEGRATED ACCESS CONTROLLER

KZ-500-U/H

VERSION 1.0

Integrated Access Controller – Installation manual

CONTENTS

1. Introduction …………..…………..…………..…………..…………..

2. Features …………..…………..…………..…………..

…….….

……

………….. 3

..…………..……….. 4

3. Specifications …………..…………..…………..…………..……………..………….. 5

4. Controller installation …………..…………..…………..…………..…………….. 5

5. Controller wiring diagram …………..…………….

……

…………..……………. 6

6. Detailed Programming Guide …………..

……

…………..

.……

…………..

8

AAT Holding sp. z o.o. Wszelkie prawa zastrzeżone.

2

Integrated Access Controller – Installation manual

1. Introduction

KZ-500-U/H Integrated access controller

The KZ-500-U/H is fully waterproof stand alone Proximity access Reader, which uses advanced microprocessor, equipped with large capacity Flash memory, supports up to10000 cards. It can read both 125KHZ HID card and

125KHZ EM card. It is so easy to add or delete card users by using the master card; besides, with infrared remote control programmer, the user can set the reader by themselves.

The KZ-500-U/H not only has the features of low power consumption, automatic selection of lock ,anti vandal alarm and exit button, but also has the protective functions against input over voltage and outputs short-circuit. The block enrollment function makes it can enroll maximum 10,000pcs HID cards or EM cards at a time within 10 minutes.

These features make the KZ-500-U/H easy in operation, safe and reliable; it is an idea choice for door access.

AAT Holding sp. z o.o. Wszelkie prawa zastrzeżone.

3

Integrated Access Controller – Installation manual

Features

Standalone controller with built in Card Reader

Waterproof, confirm to IP68

Use capacity: 10,000

Card interface: HID&EM 125KHZ card/tag

Remote control for programming

With Manager cards for fast add and delete users

Card block enrollment

Can enroll maximum 10,000pcs cards at a time within 10 minutes

Wiegand 26 input/output

Can be used as salve reader

2 pcs of KZ-500 can be interconnected

Can be used as controller by connection Wiegand reader

Anti-passback function

Alarm signal output, Door open detection

LED display

Full of 10000 users, recognizing speed <15ms.

AAT Holding sp. z o.o. Wszelkie prawa zastrzeżone.

4

Integrated Access Controller – Installation manual

Specifications

Supply Voltage

User capacity

Sleeping Current

Card type

Card Reading Distance

Wiegand interface

Operating Temperature

Operating Humidity

Environment

Lock output load

Alarm output load

Adjustable Door Relay Time

Adjustable Alarm Time

Wiring Connections

Manager card

Dimensions

DC12V±10%

10,000

<15mA

HID&EM 125khz Card/Tag

4~8cm

Wiegand 26

-25~60℃

20%~98%

Confirm to IP68

Max20A

Max20A

00-99 seconds

0- 3 minutes

Electric Lock, Exit Button, DOTL, External Alarm

Two

103*48*23mm

Installation

Drill holes on the wall or prepare the cassette.

Wire through the hole, and blanket the unused cable in case of short circuit.

Fix the back cover firmly on the cassette or the wall.

Attach the reader to the back cover.

AAT Holding sp. z o.o. Wszelkie prawa zastrzeżone.

5

Integrated Access Controller – Installation manual

Wiring

5

6

No Color Function

1

2

Green

D0

White D1

3

4

Description

Wiegand output, input signal wire D0

Wiegand output, input signal wire D1

Grey

Yellow

ALARM+

OPEN

Brown D_IN connecting to the negative pole of the alarm equipment

To connect to one part of Exit Button

Door Contact input,

Red 12V (+) 12Vdc Positive Regulated Power Input

7 Black GND (-) Negative Regulated Power Input the negative pole of the controller, connect to the other part of Exit button and door contact

Connect to the negative pole of the Lock

8 Blue VSS

9

10

Purple

Orange

L-

L+/

Alarm+

Connection Diagram

Connect to the positive pole of the lock and alarm equipment

Note: Do not power on until all wiring has been completed

AAT Holding sp. z o.o. Wszelkie prawa zastrzeżone.

6

Integrated Access Controller – Installation manual

To Reset to Factory Default

Power off, use the supplied Contact Pin to short out the 2P socket on the main board, then power on, if successful, the beeper will beep twice, the LED shines in orange, remove the Short Pin, then read the Two Manager cards

(Manager add card firstly, Manager delete card secondly), after that the LED turns in red, means reset to factory default setting successfully.

Remarks: Reset to factory default setting, the users' information enrolled is still retained. When

Re-set to Factory setting, the two Manager cards must be re-enrolled.

Sound and Light indication

Operation status

Reset to factory default setting

Sleeping mode

Operation successful

Enter into programming mode

Enter into setting

Exist from programming mode

Operation failed

Open the door

Alarm

Orange

LED

Red shines slow

Red shines

Orange shines

Red shines slow

Green shines

Red shines fast

Buzzer

Two short ring

Short ring

Short ring

Short ring

Short ring

Three short ring

Short ring

Alarm

AAT Holding sp. z o.o. Wszelkie prawa zastrzeżone.

7

Integrated Access Controller – Installation manual

Detailed Programming Guide

User settings

There are 2 ways to add and delete users:

A - By manager card; B - By remote control

A - By Manager card (The most convenient way)

To Add user by Manager Add Card

To Delete User by Manager Delete

Card

B- By Remote control

Manager add card Read card Manager add card Cards can be added continuously.

Manager delete card Read Card Manager delete card Cards can be deleted continuously.

Enter into the programming mode

firstly

To Enter the programming mode * Manager Password #

888888 is the default factory master code

Remarks: All the steps below must be done after enter into programming mode

To change the master code

To add a card user (Method 1)

This is the faster way to enter cards using ID number auto generation. The card can be either be presented or input the 8 digit card number from the card can be manually entered

To add a card user (Method 2)

This is the alternative way to enter cards using User ID Allocation. In this method a User ID is allocated to a card. Only one user ID can be allocated to a single card.

0 New Password # Repeat New Password #

The master code must be 6~8 digit number.

1 Read Card # or

1 Input Card number (8 digit) #

Card can be added continuously without exiting programming mode.

The card number is the last 8 digits of the number printing on the card.

1 ID number # Read Card # or

1 ID number # the Card number (8 digits)

#

To add a series cards users – Block

Enrollment

(It can enroll maximum 10,000pcs cards at a time within 10 minutes.)

8 ID number # 8 digits Card number #

Card quantity #

Card quantity is between 1-10,000. Of the

8 digits card number, for HID card, they are the 3 digits of a facility code and 5 digits of a serial number; for EM card, they are the last 8 digits on the card.

2 Read Card # or

2 Card number #

To delete a card user.

Note users can be deleted continuously without exiting programming mode

To delete ALL users.

(Note: This option will delete all users but Manager Cards. Be careful with use)

2 0000 #

AAT Holding sp. z o.o. Wszelkie prawa zastrzeżone.

8

Integrated Access Controller – Installation manual

Door setting

Lock power setting

Fail secure (Unlocked when power on )

4 0~99 #

0-99 is to set the door relay time 0-99 seconds.

This is the factory default, 3 seconds.

Fail safe (unlocked when power is off)

5 0~99 #

0-99 is to set the door relay time 0-99 seconds.

Anti-submarine Settings

Anti-submarine Disabled (Factory default)

Anti-submarine Master Mode:

Anti-submarine Auxiliary Machinery Mode

(Note: the detailed wiring diagram and illustrate ,please refer to “Advanced application”

3 0 #

3 1 #

3 2 #

Door open detection

Door Open Too Long (DOTL) warning. When used with an optional magnetic contact or built-in magnetic contact of the lock, if the door is opened normally, but not closed after 1 minute, the inside buzzer will beep automatically to remind people to close the door and continue for 1 minute before switching off automatically.

Door Forced Open warning. When used with an optional magnetic contact or built in magnetic contact of the lock, if the door is forced open, or if the door is opened after 120 seconds of the electro-mechanical lock not closed properly, the inside buzzer and alarm output will both operate.

To disable door open detection.

(Factory default)

To enable door open detection

6 0 #

6 1 #

Security Mode Setting

Keypad Lockout

Reader Lockout & Alarm Output options. If there are 10 invalid cards or 10 incorrect

PIN numbers in a 10 minute period either the reader will lockout for 10 minutes or the alarm will operate for 10 minutes, depending on the option selected below.

Normal status (No lockout or Alarm) 7 0 # (Factory default setting)

7 1 #

Alarm Output

7 2 #

LED Control

LED disabled

LED enabled

Alarm output time

7 3 #

7 4 #

To set the alarm output time (0-3 minutes) Factory default is 1 minute

To remove the alarm

9 0~3 #

To remove the Door Forced Open warning

To remove the Door Open Too Long warning

Read valid card or Master Code#

Close the door or Read valid card or Master Code #

To Unlock the door

To Unlock the door

Read User card

(Note that Manager Card can’t be used as User Card to unlock the door.)

AAT Holding sp. z o.o. Wszelkie prawa zastrzeżone.

9

Integrated Access Controller – Installation manual

Advanced Application

KZ-500 operating as a Controller

In this mode the KZ-500 supports a Wiegand 26 bit input so an external

Wiegand device with a 26 bit output can be connected to the Wiegand input terminals. Cards are required to be added at the external reader, except where an external ID reader is used, in this case cards can be added at either reader or controller. See figure 1.

KZ-500-U/H

c

Two KZ-500 units interconnected for a single door

In this mode two KZ-500 units are used for a single door, one for entry and the other for exit. Either device acts as the controller and reader at the same time. Users can be enrolled on either of the devices. In this mode the user capacity for one door can be up to 20000. The setting of the two KZ-500 units must be the same including the master code. See figure 2.

KZ-500-U/H #1

Figure 2.

KZ-500-U/H #2

AAT Holding sp. z o.o. Wszelkie prawa zastrzeżone.

10

Integrated Access Controller – Installation manual

Anti-passback function for single door (3 1 #)

The connection diagram is as figure 1. Install one Wiegand reader (or a KZ-500 without user information as reader) outside the door, connecting to one KZ-500

Controller inside the door, which acts as the Anti-passback Master unit. Of the two devices, they build up an anti-passback system for single door. The operation and function is as below:

4.1 Set the needed function and enroll the User Cards on the inside KZ-500 Antipassback Master unit.

4.2 With the valid user card, the user can only enter the door from the outside reader, and exit from the inside KZ-500 Controller. On the other hand, without entering record from the reader, the user can’t exit from the controller inside, also, the user can’t enter in and exit twice continuously.

Anti-passback function for 2 doors

The connection diagram is as Figure 3. Door 1 with one KZ-500 , and Door 2 with one KZ-500, set one KZ-500 on Door 1 as the Anti-passback Auxiliary unit

(3 2 #), and set the other KZ-500 on Door 2 as the Anti-passback Master unit (3

1 #). Then they build up a two doors anti-passback system, which is normally used for parking lot…etc

The operation and function is as below:

5.1 Set the needed function and enroll the User Cards from KZ-500 - Antipassback Master unit on Door 2.

5.2 With the valid user card, the user can only enter in from Door 1, and exit from Door 2. On the other hand, without entering record from the Auxiliary unit, the user can’t exit from the Master unit or Auxiliary unit, also, the user can’t enter in and exit twice continuously.

Controller KZ500 #1

Controller KZ500 #2

Figure 3.

AAT Holding sp. z o.o. Wszelkie prawa zastrzeżone.

11

AAT Holding sp. z o.o. ul. Puławska 431, 02-801 Warszawa tel. 22 546 05 46, faks 22 546 05 01 e-mail: [email protected], www.aat.pl

Warszawa

advertisement

Key Features

  • Waterproof, IP68
  • Standalone access control
  • 10,000 card capacity
  • HID&EM 125kHz card compatibility
  • Remote control programming
  • Manager cards for user management
  • Block enrollment
  • Wiegand 26 input/output
  • Slave reader capability
  • Interconnect with another KZ-500 unit

Frequently Answers and Questions

What is the maximum number of cards the KZ-500 U/H can support?
The KZ-500 U/H can support up to 10,000 cards.
What type of cards does the KZ-500 U/H support?
The KZ-500 U/H supports both 125KHZ HID and 125KHZ EM cards.
How can I add or delete users on the KZ-500 U/H?
You can add or delete users using manager cards or a remote control.
What is the anti-passback function?
The anti-passback function prevents a user from entering and exiting a door at the same time, ensuring that only one person is inside the secure area.
Can I use the KZ-500 U/H as a slave reader?
Yes, the KZ-500 U/H can be used as a slave reader.
Can I connect two KZ-500 U/H units together for a single door application?
Yes, you can connect two KZ-500 units together for a single door application.