Haier EK HSM18HEKC03/R2(DB), EK HSM18HRAC03/R2(DB), HUM18HC03/R2(DB) split-system air conditioner SERVICE MANUAL
EK HSM18HEKC03/R2(DB), EK HSM18HRAC03/R2(DB), HUM18HC03/R2(DB) are split-system air conditioners designed for domestic use. They offer a variety of features, including cooling, heating, and dehumidifying. The air conditioner is easy to use and features a remote control for convenient operation. The EK series models feature a DC inverter technology that helps to save energy and the HUM18HC03/R2(DB) model includes a healthy negative ion feature.
PDF
Download
Document
Advertisement
Advertisement
SERVICE MANUAL Order No.AC1012S001V0 Wall mounted Type DC InverterEK-Series Model No. HSM18HEKC03/R2(DB) HSM18HRAC03/R2(DB) HUM18HC03/R2(DB) HSM18HEKC03/R2(DB) HSM18HRAC03/R2(DB) HUM18HC03/R2(DB)outdoor unit indoor unit and remote controller 2010 HSM18HEKC/HRAC03/R2(DB) HUM18HC03/R2(DB) -SM Table of Contents 1. Introduction 1 2. List of Functions 6 3. Specifications 7 4. Printed Circuit Board Connector Wiring Diagram 9 5. Functions and Control 14 5.1 Main functions and control specifications of indoor unit 14 5.2 Main functions and control specifications of outdoor unit 22 5.3 Value of Thermistor 30 6. System Configuration 40 6.1 System Configuration 40 6.2 Instruction 40 7. Error Codes and Descirption 49 8. Installations 64 9. Removal Procedure 72 9.1 Removal of Indoor Unit(HSM18HEKC03/R2(DB) 72 9.2 Removal of Indoor Unit(HSM18HRAC03/R2(DB) 84 9.3 The removal procedure of outdoor 94 10. Wiring Diagrams 107 10.1 Indoor Unit ............................................................................................... 107 10.2 Outdoor Unit ............................................................................................ 108 11. Circuit Diagrams 109 12 .Description of Coding rules of Unit Model................................................112 HSM18HEKC/HRAC03/R2(DB) HUM18HC03/R2(DB) -SM Introduction 1. Introduction 1.1 Safety Cautions Be sure to read the following safety cautions before conducting repair work. The caution items are classified into “Warning” and “Caution”. The “Warning” items are especially important since they can lead to death or serious injury if they are not followed closely. The “Caution” items can also lead to serious accidents under some conditions if they are not followed. Therefore, be sure to observe all the safety caution items described below. About the pictograms This symbol indicates an item for which caution must be exercised. The pictogram shows the item to which attention must be paid. This symbol indicates a prohibited action. The prohibited item or action is shown inside or near the symbol. This symbol indicates an action that must be taken, or an instruction. The instruction is shown inside or near the symbol. After the repair work is complete, be sure to conduct a test operation to ensure that the equipment operates normally, and explain the cautions for operating the product to the customer. 1.1.1 Caution in Repair Warning Be sure to disconnect the power cable plug from the plug socket before disassembling the equipment for a repair. Working on the equipment that is connected to a power supply can cause an electrical shook. If it is necessary to supply power to the equipment to conduct the repair or inspecting the circuits, do not touch any electrically charged sections of the equipment. If the refrigerant gas discharges during the repair work, do not touch the discharging refrigerant gas.The refrigerant gas can cause frostbite. When disconnecting the suction or discharge pipe of the compressor at the welded section, release the refrigerant gas completely at a well-ventilated place first. If there is a gas remaining inside the compressor, the refrigerant gas or refrigerating machine oil discharges when the pipe is disconnected, and it can cause injury. If the refrigerant gas leaks during the repair work, ventilate the area. The refrigerant gas can generate toxic gases when it contacts flames. The step-up capacitor supplies high-voltage electricity to the electrical components of the outdoor unit. Be sure to discharge the capacitor completely before conducting repair work.A charged capacitor can cause an electrical shock. Do not start or stop the air conditioner operation by plugging or unplugging the power cable plug. Plugging or unplugging the power cable plug to operate the equipment can cause an electrical shock or fire. 1 Domestic Air Conditioner HSM18HEKC/HRAC03/R2(DB) HUM18HC03/R2(DB) -SM Introduction Warning Do not repair the electrical components with wet hands. Working on the equipment with wet hands can cause an electrical shock. Do not clean the air conditioner by splashing water. Washing the unit with water can cause an electrical shock. Be sure to provide the grounding when repairing the equipment in a humid or wet place, to avoid electrical shocks. Be sure to turn off the power switch and unplug the power cable when cleaning the equipment. The internal fan rotates at a high speed, and cause injury. Do not tilt the unit when removing it. The water inside the unit can spill and wet the furniture and floor. Be sure to check that the refrigerating cycle section has cooled down sufficiently before conducting repair work. Working on the unit when the refrigerating cycle section is hot can cause burns. Use the welder in a well-ventilated place. Using the welder in an enclosed room can cause oxygen deficiency. 1.1.2 Cautions Regarding Products after Repair Warning Be sure to use parts listed in the service parts list of the applicable model and appropriate tools to conduct repair work. Never attempt to modify the equipment. The use of inappropriate parts or tools can cause an electrical shock, excessive heat generation or fire. When relocating the equipment, make sure that the new installation site has sufficient strength to withstand the weight of the equipment. If the installation site does not have sufficient strength and if the installation work is not conducted securely, the equipment can fall and cause injury. Be sure to install the product correctly by using the provided standard installation frame. For Incorrect use of the installation frame and improper installation can cause the equipment to fall, resulting in injury. integral units only Be sure to install the product securely in the installation frame mounted on a window frame. If the unit is not securely mounted, it can fall and cause injury. For integral units only 2 Domestic Air Conditioner HSM18HEKC/HRAC03/R2(DB) HUM18HC03/R2(DB) -SM Introduction Warning Be sure to use an exclusive power circuit for the equipment, and follow the technical standards related to the electrical equipment, the internal wiring regulations and the instruction manual for installation when conducting electrical work. Insufficient power circuit capacity and improper electrical work can cause an electrical shock or fire. Be sure to use the specified cable to connect between the indoor and outdoor units. Make the connections securely and route the cable properly so that there is no force pulling the cable at the connection terminals. Improper connections can cause excessive heat generation or fire. When connecting the cable between the indoor and outdoor units, make sure that the terminal cover does not lift off or dismount because of the cable. If the cover is not mounted properly, the terminal connection section can cause an electrical shock, excessive heat generation or fire. Do not damage or modify the power cable. Damaged or modified power cable can cause an electrical shock or fire. Placing heavy items on the power cable, and heating or pulling the power cable can damage the cable. Do not mix air or gas other than the specified refrigerant (R-410A / R22) in the refrigerant system. If air enters the refrigerating system, an excessively high pressure results, causing equipment damage and injury. If the refrigerant gas leaks, be sure to locate the leak and repair it before charging the refrigerant. After charging refrigerant, make sure that there is no refrigerant leak. If the leak cannot be located and the repair work must be stopped, be sure to perform pump-down and close the service valve, to prevent the refrigerant gas from leaking into the room. The refrigerant gas itself is harmless, but it can generate toxic gases when it contacts flames, such as fan and other heaters, stoves and ranges. When replacing the coin battery in the remote controller, be sure to disposed of the old battery to prevent children from swallowing it. If a child swallows the coin battery, see a doctor immediately. 3 Domestic Air Conditioner Introduction HSM18HEKC/HRAC03/R2(DB) HUM18HC03/R2(DB) -SM Caution Installation of a leakage breaker is necessary in some cases depending on the conditions of the installation site, to prevent electrical shocks. Do not install the equipment in a place where there is a possibility of combustible gas leaks. If a combustible gas leaks and remains around the unit, it can cause a fire. Be sure to install the packing and seal on the installation frame properly. If the packing and seal are not installed properly, water can enter the room and wet the furniture and floor. For integral units only 1.1.3 Inspection after Repair Warning Check to make sure that the power cable plug is not dirty or loose, then insert the plug into a power outlet all the way. If the plug has dust or loose connection, it can cause an electrical shock or fire. If the power cable and lead wires have scratches or deteriorated, be sure to replace them. Damaged cable and wires can cause an electrical shock, excessive heat generation or fire. Warning Do not use a joined power cable or extension cable, or share the same power outlet with other electrical appliances, since it can cause an electrical shock, excessive heat generation or fire. 4 Domestic Air Conditioner HSM18HEKC/HRAC03/R2(DB) HUM18HC03/R2(DB) -SM Introduction Caution Check to see if the parts and wires are mounted and connected properly, and if the connections at the soldered or crimped terminals are secure. Improper installation and connections can cause excessive heat generation, fire or an electrical shock. If the installation platform or frame has corroded, replace it. Corroded installation platform or frame can cause the unit to fall, resulting in injury. Check the grounding, and repair it if the equipment is not properly grounded. Improper grounding can cause an electrical shock. Be sure to measure the insulation resistance after the repair, and make sure that the resistance is 1 M ohm or higher. Faulty insulation can cause an electrical shock. Be sure to check the drainage of the indoor unit after the repair. Faulty drainage can cause the water to enter the room and wet the furniture and floor. 5 Domestic Air Conditioner HSM18HEKC/HRAC03/R2(DB) HUM18HC03/R2(DB) -SM Functions Category Healthy negative ion make your room full of an abundance natural negative ions. HSM18HEK/HRAC03/R2(DB) HUM18HC03/R2(DB) N Child lock Avoid the child's wrong operation on the remote controller Y 3D air flow The 3D airflow is able to deliver the airflow horizontally and vertically. N 24Hour timer Use the timer function to set on,or off,or from on to off,or from off to on Y Easy clean design The panel is easy to wash and the airflow vents can be detached easily Y With twin-blade technology ,the airflow can be adjusted not to blow directly Y Catches most small particles and remove unpleasant odors effectively. Y Sleep mode The setting temprature and the indoor noise can be adjusted to a more comfortable level when you set the "sleep mode"during night sleep Y 4 Fan setting Slect the fan speed LO,MED,HI,AUTO Y adjust the last fixed operation mode automatically. Y Quick cooling or heating Y lower noise operation condition Y Intelligent air Anti-mold filter Auto mode Power mode Soft mode Constant temperature Make dehumidifying in the room while keeping the constant temperature inside dehumidification Note: Y: Holding Functions N : No Functions N HSM18HEKC/HRAC03/R2(DB) HUM18HC03/R2(DB) -SM HSM18HEKC03/R2(DB) 1.5~4.9~5.5 1.6~5.35~5.8 HSM18HRAC03/R2(DB) 1.5~4.9~5.5 1.6~5.35~5.8 5100~16700~18700 5400~18200~19800 5100~16700~18700 5400~18200~19800 1290~4214~4730 1376~4601~4988 6.9 6.6 400~1530~1950 405~1480~2000 6.9 6.6 400~1530~1950 405~1480~2000 97 96 97 3.20 3.61 3.20 3.61 6.35 6.35 12.7 12.7 16.0 16.0 25 25 15 15 7 10 20 20 14.2 15.0 14.2 15.0 12.7 13.5 12.7 13.5 11.2 13.0 11.2 13.0 - - - 4 4 0.15 0.15 0.15 0.15 33 33 33 33 938X187X265(EK1) 938X191X265(EK2) (WxDxH) 1376~4601~4988 96 - (WxDxH) 1290~4214~4730 2.0 2.0 1016X304X360 10.5 938X204X265 1016X304X360 10.5 12.5 12.5 42/39/36 42/39/36 52 52 HSM18HEKC/HRAC03/R2(DB) HUM18HC03/R2(DB) -SM HUM18HC03/R2(DB) SNB130FGYM2 900 FV50S 0.5 R410a 1.2 35 35 1235.5 1235.5 40 6.9 6.6 1530 1480 98 98 15 (WxDxH) 810X288X688 (WxDxH) 949X406X745 43 46.5 51 61 5 8 HSM18HEKC/HRAC03/R2(DB) HUM18HC03/R2(DB) -SM Connector Wring Diagram 4.Printed Circuit Board Connector Wiring Diagram 4.1˖Indoor unit Connectors Connectors PCB(1) (Control PCB) For HUM18HC03/R2(DB) 1) CN26 Connector for fan motor 2) CN1 Connector for heat exchanger thermistor and Room temperature thermistor 3) CN11 Connector for UP&DOWN STEP motor 4) CON2 Connector for power N wire 5) CON1 Connector for power L 6) CN32 Connector for display board 7) C0N6,C0N8 Connector for ions generator 8) CON7 Connector for communicate between the indoor board and the outdoor board 9) CON9 Connector for new airflow wire 10) CN34 Connector for long-range control 11) CN20 Connector for room card Note: Other designations PCB(1) (INdoor Control PCB) 1) SW1 Connector for Forced operation ON / OFF switch 2) SW2 1 Select remote code A or B,2 Select 25 or 35 ,3 Select room card able or disable 3) SW4 Select 20 or other,if select 20,SW2 must select 25(Select ON) 4) RV1 Varistor 5) FUSE1 Fuse 3.15A/250VAC 9 Domestic Air Conditioner HSM18HEKC/HRAC03/R2(DB) HUM18HC03/R2(DB) -SM Connector Wring Diagram PCB(1) CN26 CN1 SW1 CN11 CN32 CN20 CON6 CON1 CON9 CON2 CON6 CON7 CN34 10 Domestic Air Conditioner HSM18HEKC/HRAC03/R2(DB) HUM18HC03/R2(DB) -SM Connector Wring Diagram 4.2: outdoor unit Connectors PCB(1) (Control PCB) 1) CN1,CN2 Connector for power N and L 2) CN3 Connector for ground 3) CN6 CN7 Connector for terminal to indoor unit 4) CN25 Connector for DC POWER 15Vand 5V to the module board 5) CN9,CN10 Connector for CN2,CN1 on the module board 6) CN12 Connector for AC fan motor 7) CN11 Connector for four way valve coil 8) CN17,CN18,CN19, CN47 Connector for thermistors 9) CN24 Connector for communicate between the control board and the module board 10) CN25 CN28 Connector to P and N of the module board 11) CN36 Connector for communicate between indoor and outdoor unit 12) CN15 Connector for electric expansion valves 13) CN45 Connector for terminal socket protect 14) CN22 Connector for DC fan motor PCB(2) (module PCB) CN10 Connector for the DC power 5V and 15V form the control PCB CN11 Connector for communicate between the control board and the module board P( CN8), N(CN9) Connector for capacitance board LI (CN3),LO(CN4) Connector for reactor CN5ˈCN6ˈCN7 Connector for the U, V, W wire of the compressor Note: Other Designations PCB(1) (Control PCB) 1) FUSE 1, (25A,250VAC) FUSE 2(1A,250VAC) 2)LED 1 keep light representative normal ,if keep flash interval representative trouble Alarm 3)RV1,RV2,RV3 Varistor 11 Domestic Air Conditioner HSM18HEKC/HRAC03/R2(DB) HUM18HC03/R2(DB) -SM Connector Wring Diagram PCB(1) CN28 CN25 CN22 CN23 CN22 CN21 CN20 CN19 CN18 CN17 CN47 CN16 CN15 CN45 CN12 CN1 CN2 CN11 CN36 CN10 CN8 CN4 CN7 CN6 12 Domestic Air Conditioner HSM18HEKC/HRAC03/R2(DB) HUM18HC03/R2(DB) -SM Connector Wring Diagram PCB(2) CN4 CN2 CN1 CN3 CN10 CN9 CN8 CN7 CN5 CN6 CN11 13 Domestic Air Conditioner Function and control HSM18HEKC/HRAC03/R2(DB)HUM18HC03/R2(DB)-SM 5.Funcitions and Control 5.1 Main functions and control specification of indoor unit 5.1.1 Automatic operation When the running mode is turned to automation after starting the system, the system will first determine the running mode according to the current room temperature and then will run according to the determined mode. Tr in the following selection conditions means room temperature, Ts means setting temperature, Tp means temperature of indoor coil pipe Tr≥23ć Choose Cooling Mode Tr˘23ć Choose Heating Mode After turning to the automation mode, the running mode can be switched between cooling mode, fan mode and heating mode according to the change of the indoor ambient temperature. But the automatic conversion between cooling mode and heating mode must be conducted after 15 minutes. 5.1.2 Cooling operation mode Temperature control range: 16ć---30ć Temperature difference: ±1ć * Control features: When Tr˄input airflow˅>Ts˄set temperature˅ć, the compressor will be opened,the indoor fan will operate at the set speed and the mode signal will be sent to the outdoor system. When Tr˄input airflow˅< Ts˄set temperature˅ć, the compressor will be opened,the indoor fan will operate at the set speed and the mode signal will be sent to the outdoor system. The system will keep the original status if Tr= Ts. Airflow speed control: (temperature difference 1ć) Automatic: When Tr>=Ts+3ć, high speed. When Ts+1ć=<Tr<Ts+3ć, medium speed When Tr<Ts+1ć, low speed When the sensor is off, low speed When the airflow speed has no delay from the high to low switching, the speed should be delayed for 3 minutes (remain at high speed for 3 minutes.) before the next switch. Manus: When the system is operating, you can set the high, medium or low speed manually. ( When the sensor is on or off, the system will change the speed 2 seconds after receiving the signal.) *Airgate location control: the location for the airgate can be set according to your needs. *Defrosting function: preventing the frosting on the indoor heat exchanger (when cooling or demoisture). When the compressor works continuously for 1/6 minutes (adaptable in EEPROM) and the temperature of the indoor coils has been below zero centigrade for 10 seconds, the compressor will be stopped and the malfunction will be recorded in the malfunction list. The indoor system will continue to run. When the temperature of the indoor coil is raised to 7ć, the compressor will be restarted again (the prerequirement of 3 minutes’ delay should be satisfied.) * timing system on/off function. * Dormant control function. 14 Domestic Air Conditioner HSM18HEKC/HRAC03/R2(DB)HUM18HC03/R2(DB)-SM 5.1.3 Function and control Demoisture mode. * temperature control range: 16---30ć * temperature difference: ±1ć Control feature: send the demoisture signal to the outdoor system. When Tr>Ts+2ć, the compressor will be turned on, the indoor fan will operate at the set speed. When Tr is between the Ts and Ts+2ć, the outdoor system will operate at the high demoisture frequency for 10 minutes and then at the low demoisture mode for six minutes. The indoor fan will operate at low speed. When Tr< Ts, the outsystem will be stopped, the indoor fan will be stopped for 3 minutes and then turned to the low speed option. All the frequency converses have a ±1ć difference. * Wind speed control: Automatic: When Tr >= Ts+ 5ć, high speed. When Ts+3ć≤Tr< Ts+5ć, medium speed. When Ts+2ć≤Tr< Ts+3ć, low speed. When Tr<Ts+2ć, light speed. If the outdoor fan stopped, the indoor fan will be paused for 3 minutes. If the outdoor fan stopped for more than 3 minutes and the outdoor system still operates, the system will be changed into light speed mode. When the airflow speed has no delay from the high to low switching, the speed should be delayed for 3 minutes (remain at high speed for 3 minutes.) before the next switch. Manual: When the sensor is off or Tr< Ts+3ć, the manual operation can not be made. (obligatory automatic operation.) *Airgate location control: the location for the airgate can be set according to your needs. *Defrosting function: preventing the frosting on the indoor heat exchanger (when cooling or demoisture). When the compressor works continuously for 1/6 minutes (adaptable in EEPROM) and the temperature of the indoor coils has been below zero centigrade for 10 seconds, the compressor will be stopped and the malfunction will be recorded in the malfunction list. The indoor system will continue to run. When the temperature of the indoor coil is raised to 7ć, the compressor will be restarted again (the prerequirement of 3 minutes’ delay should be satisfied.) * coil protection (synchronic overheating protection) are installed for the four directions latch malfunctions when demoisturing. * timing system on/off function. * Dormant control function. 5.1.4 Heating operation mode. * temperature control range: 16---30ć * temperature difference: ±1ć * control feature: the temperature compensation is automatically added and the system will send the heating signals to the outdoor system. If Tr≤Ts, the outdoor compressor is turned on, the indoor fan will be at the cold air proof mode. If Tr>Ts+3, the outdoor system is turned off, the indoor fan will be at the heat residue sending mode. If Tr<Ts+3ˈthe outdoor system will be turned on again, the indoor fan will be at the cold air proof mode. 15 Domestic Air Conditioner Function and control HSM18HEKC/HRAC03/R2(DB)HUM18HC03/R2(DB)-SM *Indoor fan control manual control: You can choose high, medium, low and automatic speed control. Automatic: When Tr<Ts, high speed. When Ts=<Tr=<Ts+2ć, medium speed. When Tr> Ts+2ć, low speed. When the airflow speed has no delay from the high to low switching, the speed should be delayed for 3 minutes (remain at high speed for 3 minutes.) before the next switch. *Airgate location control: the location for the airgate can be set according to your needs. Coldair proof operation 1. The indoor operation within 4 minutes after the start up is as the following diagram, the air speed can be raised only after the speed has reached a certain level. Set speed Heat start temp 1 Low speed Keep the high speed. The fan doesn’t stop Heat start temp 2 Light speed Heat start temp 3 Fan/off Heat start temp 4 Fan/off 2. 4 minutes after the start up of the indoor fan, the light airflow and the low airflow will be turned to the set speed airflow. 3. In the cold air proof operation, the fan won’t stop after the start up. 4. During the cold air proof operation, the indoor system will continuously send ‘indoor high speed’ signals to the outdoor system. * Residue heat sending. The indoor fan will send the residue heat at a low speed for 20 seconds. If other conditions are satisified, when the compressor stops, the indoor system will operate at a light speed. The indoor fan will stop when the coil temperature is below the ‘heat start temp 4’. * Defrosting. When the system receives the defrosting signal from outdoors, the indoor fan will stop and the indoor temperature display won’t change. At the time, any indoor coil malfunctions will be neglected. When the outdoor defrosting finishes, the coil malfunction will still be neglected until the compressor has been started up for 30 seconds. The indoor temperature display will not change and the system operates at the cold air proof mode. * Automatic heating temperature compensation: when the system enters the heating mode, the temperature compensation (4) will be added. When the status is switched off, the compensation will be erased. 5.1.5 strength operation a. the system enters the mode after receiving the ‘strength signal’. Send strength operation signal to the outdoor system. Strength operation quit if you change the fan mode or operation mode . The mode change finishes the strength operation. Entering ‘mute’, you can have normal operation or signal control such as timing to finish the strength 16 Domestic Air Conditioner Function and control HSM18HEKC/HRAC03/R2(DB)HUM18HC03/R2(DB)-SM operation. When the system is at the automatic option ,There is no strength/ mute function,. 5.1.6 Mute operation the system enters the mode after receiving the ‘mute signal’. a. Mute heating: the airflow speed is slight, the system sends the mute signal to the outdoor system. b. mute cooling: the airflow speed is slight, the system sends the mute signal to the outdoor system. When the compressor operates, the airflow speed is mute speed. EEPROM is adaptable. Mute operation can not work under the demoisturing and airflow-sending operation. 5.1.7 Air refreshing After receiving the signal from the remote control,(HV series: the background light of the ‘health’ logo is green. HS series: the ‘health’indicator will be lighted). If the fan operates, the negative ion generator operates to realize the negative sending function. If the indoor fan stops, the negative ion generator is turned off. When the negative ion generator is turned off, if the air refreshing system is turned on, the negative ion generator will be turned on when the fan operates. 5.1.8 Timing. You can set 24 hours’ on/off timing accordingly. After the setting, the timing indicator will be lightened. Also, the light will be turning off after the timing is finished. The followings are several timing methods. 1.system /on timing: The timing indicator will be lightened and the indoor system is under the waiting mode. The light will be turned off when the timing is finished and the rest of the system will operate under a normal condition. The timing starts since the last reception of the timing singal. You can have the dormacy setting under the timing mode, the order of your settings will be operated according to the timing settings. 2.system /off timing: When the system is turned on, the timing indicator is lightened, the rest of the system will operated under a normal condition. When set time comes, the indicator light will be turned off and the system will be turned off. If you have set the dormant functions, the order of your settings will be operated according to the timing settings. 3.system /on and off timing: The settings will be completed according to the orders. 5.1.9 Dormant operation The dormant timing is an eight hours unadaptable one. The timing signs are shown on the E series board. (RC series show the dormant signal, the timing light is lighted on the 6 lights board). 2.1 Under the cooling/ demoisture operation, after the setting of the dormant operation, the set temperature will be raised for 1 centigrade after 1 hour’s operation and will be raised for 1 centigrade 1 hour later. The system will keep this status for 6 hours and then close. 2.2 Under the heating mode, after the setting of the dormant operation, the et temperature will fall 2 17 Domestic Air Conditioner HSM18HEKC/HRAC03/R2(DB)HUM18HC03/R2(DB)-SM Function and control centigrades after 1 hour’s operation and will fall 2 centigrades 1 hours later. 3 hours after the preceding operations, the set temperature will be raised for 1 centigrade and the system will keep this status for 3 hours and then close down. 2.3 During the dormant time, except the change of the system mode or a new press on the dormant setting keys, the timing of the 8 hours dormancy will take the first timing as the start time, any presses on other keys will not affect the original timing. 2.4 Indoor fan control under the dormant operation. If the indoor fan is at the high speed before the dormant operation setting, the speed will be turned to medium after the setting. If the fan is at the medium speed before the dormant setting, the speed will be turned to low after the setting. If the fan is at the low speed before the dormant setting, the speed will not change. 5.1.10 Urgent on/off input Press the urgency button the buzzer will ring. The system will enter the automatic mode if you don’t press the button for more than 5 seconds. Under the system off mode, if you press the urgency key for 5 to 10 seconds, the system will start the test operation. Under the system off mode, If you press the urgency key for 10 to 15 seconds, the display screen will show the resume of the last malfunction. If the system is under operation, the press on the urgency key will stop it. Under the system off mode, the display screen will show no sign. Urgency operation: If you press the urgency key for less than 5 seconds, the buzzer will ring when you press the on/off key. The system will enter the urgency operation when the urgency key is loosened. The urgency operation is fully automatic. Test operation. The inlet temperature sensor doesn’t work, the indoor fan and the indoor air direction board motor works synchronically. High speed airflow, cooling, outdoor system on, etc, will send the ambient temperature 30 centigrade and coil temperature 16 centigrade information to the outdoor system. Test operation The defrost protection of the evaporator doesn’t work. The temperature control doesn’t work. The test operation will be finished in 30 minutes. The test operation can be stopped by the relative commands from the remote control. 5.1.11 Low load protection control In order to prevent the frosting of the indoor heat interaction device, the outdoor system will be stopped if the indoor heat interaction temperature is below zero centigrade for 5 minutes, but the fan will continue to operate. The outdoor system will be started again when the heat interaction temperature is above 7 centigrade and the system has been stopped for 3 minutes. The malfunction will be stored in the malfunction resume and will not be revealed. 18 Domestic Air Conditioner Function and control HSM18HEKC/HRAC03/R2(DB)HUM18HC03/R2(DB)-SM 5.1.12 High load protection control The outdoor system will be stopped if the coil temperature is above 65ć for 2 minutes. The indoor fan will be controlled by the thermostat. The outdoor system can be restarted when the coil temperature is below 42ć and the system has been stopped for 3 minutes. The malfunction will be stored in the malfunction resume and will not be revealed. 5.1.13 Abnormal operation of indoor system When the outdoor system operates, if the indoor system operation differs from the outdoor system, the abnormal operation malfunction will be reported. 10s after the report, the indoor system will be closed. Outdoor system mode Indoor system mode conflicts cooling heating yes cooling cooling no cooling airflow no heating heating no heating airflow yes heating cooling yes 5.1.14 Malfunction list resume. Nothing is presented if there is no code list. The malfunction display will automatically finish in 10 seconds. The remote control only receives the sigals for stop. According to the signals, the malfunction resume presentation finishes. The resume restores after the power supply restores. 5.1.15 Abnormality confirmation approaches. 1.indoor temperature sensor abnormality: under the operation, the normal temperature ranges from 120 degree to -30 degree. When the temperature goes beyond this range, the abnormality can be confirmed. If the temperature goes back into the range, the system will automatically resume. 2.indoor heat interaction sensor abnormality: under the operation, the normal temperature ranges from 120 degree to -30 degree. When the temperature goes beyond this range, the abnormality can be confirmed. If the temperature goes back into the range, the system will automatically resume. 3.indoor malfunction: Out door malfunction: When the indoor system receives the outdoor malfunction codes, it will store the code into E2 for the malfunction list resume. The indoor system will continue to operate according to the original status, the malfunction code will not be revealed or processed. 4.transmission abnormality: If the indoor system can’t receive the outdoor system for 8 minutes, the communication abnormality 19 Domestic Air Conditioner Function and control HSM18HEKC/HRAC03/R2(DB)HUM18HC03/R2(DB)-SM can be confirmed and reported and the outdoor system will be stopped. 5.1.16 Single indoor system operation * Enter condition: First, Heating operation mode, set the high speed airflow and 30 centigrade set temperature, then press the dormant keys for 6 times within 7 seconds, the system will feedback with 6 rings. * After the system enters the separate indoor system operation mode, the indoor system will operate according to the set mode and neglect the communication signals of the outdoor system. However, it has to send signals to the outdoor system. * Quitting condition: This mode can be quitted after receiving the quitting signal from the remote control or urgency system. The indoor system thus can quit the single operation mode. 5.1.17 Power cut compensation. * Entering condition: Press dormant button 10 times within 7 second, the buzzer will ring 4 times and the present system status will be stored into the EEPROM of the indoor system. * After entering the power cut compensation mode, the processing of the indoor system should be as the followings: Remote control urgency singal: operate according to the remote control and the urgent conditions, the present status will be stored into the EEPROM of the indoor system. * Quitting conditions: Press dormant button 10 times within 7 seconds and the buzzer will ring twice. 5.1.18 Fixed frequency operation. 1. Fixed cooling: a. under G code condition: high speed cooling, set 16ć, press temperature ‘-‘ key and the set key at the same time. The system will enter the fixed frequency operation after the buzzer rings twice. b. The proceeding programs are as the follows: Entering the fixed frequency operation, you can set the fixed strength location 1 and send the coolng signal to the outdoor system. Meanwhile, you can fix the indoor system at high speed mode, the location of the airflow directin board can be switched to the maximal position. c. Quitting condition: The fixed frequency cooling can be quitted after receiving the remote signal, and the system will enter the remote setting status. 2. Fixed heating: a. under G code condition: high speed heating, set 30ć, press temperature ‘+‘ key and the set key at the same time. The system will enter the fixed frequency operation after the buzzer rings twice. b. The proceeding programs are as the follows: Entering the fixed frequency operation, you can set the fixed strength location 1 and send the heating signal to the outdoor system. Meanwhile, you can fix the indoor system at high speed mode, the location of the airflow directin board can be switched to the maximal position. c. Quitting condition: The fixed frequency heating can be quitted after receiving the remote signal, and the system will enter the remote setting status. 20 Domestic Air Conditioner Function and control HSM18HEKC/HRAC03/R2(DB)HUM18HC03/R2(DB)-SM 5.1.19 Time cutting function: connect the test program terminal on the mainboard after connecting the system to the power circuit. The CPU of the main control will be 60 times faster. 5.1.20 Display function When the system starts up or power on, the background and the LED will be fully lighted for 3 seconds. Then the LED displays the mode you have set. 5.1.20.1 Three-color background The multi-color indicator is not lighted when the system is off. The mode-switching will change the indicator colors. Red color is for heating mode, blue for cooling, water color for demoisturing, white for automatic mode, pink for airflow sending, green for health mode and yellow green for air refreshing. The colors health, refreshing colors are preferred to the mode colors. If different status exist at the same time, then the last set color will be shown. The lighting key of the control board can turn on or off the display. 5.1.20.2 LED display *Set timing to display timing signs, set dormant mode to display dormant sign.(The dormant signs will be shown on the G series panels.), set health mode to display health sign, set new airflow mode to display new airflow sign and set violet disinfection to display health sign. *Set auto, heating, demoisturing, heating to display the relative signs. When you use a remote control to switch cooling, demoisturing and heating modes, the set temperature will be shown and the screen board will return to the room temperature 5 seconds later. If you choose the airflow sending mode, the screen board will show the room temperature directly. *If the system is under malfunction status, the display will show the malfunction code. Please refer to the malfunction list. 5.2 The control system of outdoor unit 5.2.1˖The operation frequency of outdoor unit and its control 5.2.1.1˖The operation frequency control of compressor The operation frequency scope of compressor˖ Mode Minimun operation frequency Maximun operation frequency Heating 20 Hz 100Hz Refrigeration 20 Hz 9 0 Hz 5.2.1.2˖The starting of compressor When the compressor is started for the first time, it must be kept under the conditions of 58Hz,88Hz for one minute (the overheating protection of the outdoor unit air-blowing temperature, immediately decrease the frequency when the compressor is overflowing and releasing the pressure)ˈthen it can be operated towards the target frequency. When the machine runs normally, there’s no such process. After starting the compressor for operation, the compressor should run according to the calculated frequency, and every determined frequency for protection should be prior to the calculated frequency. 5.2.1.3˖The speeds of increasing or decreasing the frequency of the compressor 21 Domestic Air Conditioner Function and control HSM18HEKC/HRAC03/R2(DB)HUM18HC03/R2(DB)-SM The speed of increasing or decreasing the frequency rapidly 1 -----------1HZ/second The speed of increasing or decreasing the frequency slowly 2 -----------1HZ/10seconds 5.2.1.4˖The calculation of the compressor’s frequency 1˅ǃThe minimum/maximum frequency limitation AˊWhile refrigerating: ˢˉ˩˝˴ˉ̎ is the maximum operation frequency of the compressor; ˢˉ˩INˉ̎ is the minimum operation frequency of the compressor. BˊWhile heating: ˢˉ˩˝˴ˉ̀ is the maximum operation frequency of the compressor; ˢˉ ˩INˉ̀is the minimum operation frequency of the compressor. 1˅ǃThe frequency limitation which is affected by the environment temperature. Heating mode: Serial No. Temperature scope Frequency limitation 1 Wh_c<-12 Max_hz8 100 HZ 2 Wh_c<-8 Max_hz7 100HZ 3 Wh_c<-2 Max_h z4 100HZ 4 Wh_c<5 Max_hz5 90 HZ 5 Wh_c<10 Max_hz1 80 HZ 6 Wh_c<17 Max_hz2 70 HZ 7 Wh_c<20 Max_hz6 60HZ 8 Wh_c>˙20 Max_hz3 48HZ Remarks: the above are the maximum frequency limitations of the complete appliance which are affected by the environment, and they have nothing to do with the ability of the indoor unit. Refrigeration/dehumidification mode: Serial No. Temperature scope Frequency limitation 1 Wh_c<28 Max_hz1 45HZ 2 Wh_c<32 Max_hz2 70 HZ 3 Wh_c<40 Max_hz3 90 HZ 4 Wh_c<48 Max_hz4 70 HZ 5 Wh_c>˙48 Max_hz5 48 HZ Remarks: the above are not only the maximum frequency limitations of the complete appliance which are affected by the environment, but also the maximum ability limitation of the system. When the starting ability is not the maximum, its maximum frequency limitation is calculated by the following equations: The frequency limitation which is affected by the temperature and under the condition of actual ability ˙the actural running system ability*the maximum frequency which is limited by the temperature and under the condition of maximum ability/the maximum designing ability of the system ΔT=∑˄ΔTi*Pi˅/∑Pi (ΔTi=|Tst_i-Tnh_i the indoor environment temperature| ;Pi˙i the ability of the indoor unit) Refrigeration/dehumidification: <1 ˙1 ˙2 ˙3 >=4 50% 70% 100% 120% 140% ΔT <1 ˙1 ˙2 ˙3 >=4 The percentage of the 50% 70% 100% 140% 140% ΔT The percentage of the rated frequency P Heating mode˖ rated frequency P 22 Domestic Air Conditioner HSM18HEKC/HRAC03/R2(DB)HUM18HC03/R2(DB)-SM Function and control K=∑Ki/the number of running machines The indoor set Breeze Low Medium High Strong Quiet airflow speed The percentage of the Healthy airflow 70ˁ 70% 90% 100% 120% 70% 70% rated frequency Ki The calculation of the actual output frequency: when there is no healthy airflow: F =F-ED-*×P×K When the healthy airflow has been set: F =F-ED-*×P×K˄airflow speed˅×K˄healthy airflow˅ When refrigerating, it is needed to satisfy ˢˉ˩INˉ̀< F<ˢˉ˩˝˴ˉ̀ When heating, it is needed to satisfy ˢˉ˩INˉr< F<ˢˉ˩˝˴ˉr 5.2.2: The outdoor fan control (exchange fan) When the fan is changed among every airflow speed (including stop blowing), in order to avoid the airflow speed from skipping frequently, it must be kept under each mode for over 30 seconds, and then it can be changed to another mode (when refrigerating, the time is changed to 15 seconds). 5.2.2.1:The outdoor fan control when refrigerating or dehumidifying After the compressor is started for 5 seconds, the outdoor fan is started at the medium speed at first, after 30 seconds,it begins to control the airflow speed according to the temperature conditions of the outdoor environment. The temperature of the The temperature of the outdoor outdoor air ˄Ta˅ coil˄Te˅ Airflow speed Ta≥ 30 ć —— High 26ć≤ Ta<30ć —— K e e p in g t h e s p e e d 24 ć≤ Ta<26ć —— M edi um 23 ć≤ Ta<24ć —— K e e p in g t h e s p e e d 5 ć≤ Ta<23ć —— Low Ta<5ć 15 ć≤ Te Low 15ć>Te Stop 5.2.2.2:The outdoor fan control when heating The temperature of the outdoor Airflow speed air ˄Ta˅ Ta≥ 22 ć Low 19ć≤ Ta<22 ć Keep ing the speed 16ć≤ Ta<22 ć Me di u m 14ć≤ Ta<16 ć Keep ing the speed Ta<14ć High 23 Domestic Air Conditioner Function and control HSM18HEKC/HRAC03/R2(DB)HUM18HC03/R2(DB)-SM 5.2.3˖The control of the outdoor electronic expansion valve When starting the compressor: the opening size of the valve must be guaranteed to have entered into the standard opening size, and then the compressor can be started. When refrigeration is in vain (the machine is shut down or is in the state of retrograde operation), the opening size of the expansion valve of the indoor unit is 5 steps; When heating is in vain, the opening size of the expansion valve of the indoor unit is 55 steps; When the outdoor unit is shut down, the valve is opened completely for 2 minutes, and then begin initialization. The scope of refrigerationg valve 60-----480 steps The scope of heating valve 90-----480 steps The valves are adjusted according to the degree of superheat —SHaˈƸSHa. 5.2.4˖Four way control For the details of defrosting four-way valve control, see the defrosting process. Four way working in other ways: Under the mode of heating, open the four-way valve, when the compressor is not started or changed to non-heating mode, make sure the compressor is stoped for 2 minutes, and then close the four-way valve. 5.2.5˖The outdoor defrosting control A.The conditions for entering into defrosting mode When starting running heating, the compressor continuously runs for over 10 minutes, after running for 45 minutes in all (defrosting is ended or when entering into refrigeration mode, clear the compressor’s cumulative run time), through detecting the defrosting sensor TCS˄detect the defrosting situation of the heat exchanger of the outdoor unit˅and the outdoor environment temperature sensor TA, and meeting the following conditions continuously for 2 minutes, the machine enters into the defrosting operation: TCS≤C×TAˉα α is determined as the following according to the data of EEPROM: C selcet˖if Tao˘0ćˈC=0.8;if Tao≥0ćˈC=0.6 ˈαis read from EEPROMˈNormal State: α=6 The temperature limitation for entering into defrosting mode -15ć≤C×TAˉα≤-5ć B.Defrosting time interval When the result of C×TAˉα is in the scope of -15ć≤C×TAˉα, the interval between two defrostings is 45 minutes (the time interval which is in 57 digits in EEPROM can be adjusted˅ When the result of C×TAˉα is in the scope of C×TAˉα<-15ć, the time interval between two defrostings is 65 minutes. C.Defrosting operation When starting defrosting, the compressor stops for 1 minute at first, and the outdoor fan is running, after 55 seconds, the four-way valve is off. When the compressor is started, the outdoor fan is stoped, the compressor stops for 30 seconds at the conditions of 58HZ, and then runs towards the target frequency—88HZ. During defrosting period, the protections, such as current of the compressor, compressor’s blowing 24 Domestic Air Conditioner HSM18HEKC/HRAC03/R2(DB)HUM18HC03/R2(DB)-SM Function and control and so on, are in effect. During defrosting period, the compressor which is stoped because of protection or malfunction will reinstate after stoping for 3 minutes, and don’t clear the cumulated run time. When it is satisfied with the continuously running time, it will enter into the defrosting mode. After entering into defrosting mode, make sure the compressor runs for at least for 2 minutes, and then it can withdraw from defrosting. If a single machine causes defrosting, the other machines all involve in defrosting. D.The conditions of withdrawing from defrosting The defrosting operation will change to heating operation, if any of the following conditions is satisfied: ˄1˅ ˖The temperature of the outdoor heat exchanger is continuously over 7ć for 80 seconds. ˄2˅ ˖The temperature of the outdoor heat exchanger is continuously over 12ć for 5 seconds. ˄3˅ ˖Continuously run defrosting for 11 minutes˄56 digits in EEPROM can be adjusted˅. EˊWhen satisfying the conditions of withdrawing from defrosting, the machine works as the followings: The compressor stops, the outdoor fan is started, and the four-way valve is closed, after 60 seconds the compressor runs according to the starting process. 5.2.6 Protection function 5.2.6.1˖TTC high temperature-preventing protection Once the machine is started, it can run TTC overheating protection of air-blowing, but air-blowing sensor malfunction must alarm after 4 minutes during which the compressor is started (during the course of self-detection, there’s no such limitation) Sensor detection methods: 100 times (one cycle of procedure run is one time, and about 5ms, detection method for each time: continuously sampling for 8 times, then order them and take the mean value of the middle 2 values), take the mean value. TTC˄ć˅ 117 Abnormal stop Decreasing the frequency rapidly˄1HZ/second˅ 112 Decreasing the frequency slowly (1HZ/10seconds) 108 105 The frequency doesn’t change. Increasing the frequency (1HZ/10second) 98 Increasing the frequency˄1HZ/1second˅ TTC>=110ć lasts for 20 seconds. Overheating protection of air-blowing, alarm malfunction to the indoor, others don’t last. 5.2.6.2˖TC high temperature-preventing control of the indoor heating unit˖ Tpg_indoor is the highest value of the effective indoor unit (start it and it is in accord with the running 25 Domestic Air Conditioner Function and control HSM18HEKC/HRAC03/R2(DB)HUM18HC03/R2(DB)-SM state). The indoor heat exchanger sensor tests the temperature of the indoor heat exchanger. If the temperature is higher than 55ć, decrease the rotate speed of the compressor and do the high temperature-preventing protection of the indoor heat exchanger; if the temperature of the indoor heat exchanger is lower than 47ć, recover to the normal control. TC Fgh_t1ˉ2 Fgh_t2ˉ2 N P Fgh_t3ˉ2 Q Fgh_t4—2 Fgh_t5—2 Normal R The compressor stops Fgh_t1 65ć Decreasing the frequency rapidly Fgh_t2 63ć Decreasing the frequency slowly Fgh_t3 55ć Prohibiting increasing the frequency Fgh_t4 52ć Increasing slowly Fgh_t5 48ć N˖Decreasing at the speed of 1HZ/1 second P˖Decreasing at the speed of 1Hz/10 seconds Q˖Continue to keep the last-time instruction cycle R˖Increasing at the speed of 1Hz/10seconds Remarks: the outdoor unit 5.2.6.3 The control of preventing the overcurrent of the compressor˖ ●During the starting process of the compressor, if the curren of the compressor is greater than 12A for 3 seconds, stop the compressor and alarm, after 3 minutes, start it again, if such state appears 3 times in 20 minutes, stop the compressor and alarm, and confirm the malfunction. Then continue to run it only after the the power is off. ●During the starting process of the compressor, if the AC current is greater than 11A, the frequency of the compressor decreases at the speed of 1HZ/second. ●During the starting process of the compressor, if the AC current is greater than 10A, the frequency of the compressor decreases at the speed of 0.1HZ/second. ●During the starting process of the compressor, if the AC current is greater than 9.5A, the frequency of the compressor increases at the prohibited speed. ●During the starting process of the compressor, if the AC current is greater than 9A, the frequency of the compressor increases at the speed of no faster than 0.1HZ/second. 5.2.6.4 The protection function of AC current: During the starting process of the compressor, if the AC current is greater than 10.5A, the frequency of the compressor decreases at the speed of 1HZ/second. During the starting process of the compressor, if the AC current is greater than 9.5A, the frequency of the compressor decreases at the speed of 0.1HZ/second. During the starting process of the compressor, if the AC current is greater than 9.0A, the frequency of the compressor increases at the prohibited speed. During the starting process of the compressor, if the AC current is greater than 8A, the frequency of the compressor increases at the speed of no faster than 0.1HZ/second. 26 Domestic Air Conditioner Function and control HSM18HEKC/HRAC03/R2(DB)HUM18HC03/R2(DB)-SM Remarks: when the outdoor temperature is high, there’s compensation for AC current protection. ŁWhen the outdoor environment temperature is higher than 40ć, AC current protection value decreases by 1.5A łWhen the outdoor environment temperature is higher than 50ć,AC current protection value decreases by 2.5A 5.2.6.5 Antifreezing protection of the indoor heat exchanger When refrigerating/heating, prevent freezing. Tpg_indoor Ў is the minimum value of the effective indoor unit (start it and it is in accord with the running state). 12ć//ice_temp_4+2 ice_temp_4 10ć Increasing slowly 8ć//ice_temp_3+2 Keeping the frequency ice_temp_3 6ć ice_temp_2 5ć ice_temp_1 3ć Decreasing slowly Decreasing rapidly 0ć ice_temp_1 Stop When Tpg_indoorLJ ice_temp_1ć, the frequency of the compressor decreases at the speed of 1HZ/1second. When Tpg_indoorLJ ice_temp_2ć, the frequency of the compressor decreases at the speed of 1HZ/10seconds. When Tpg_indoor begins to rise again, and ice_temp_2LJ=Tpg_indoorLJ= ice_temp_3ć, the frequency of thecompressor doesn’t change. When ice_temp_3LJTpg_indoorLJice_temp_3+3ć, the frequency of the compressor increases at the speed of 1HZ/10seconds. For example, Tpg_indoor<= 0ćˈlast for 2 minutes, and then the outdoor unit will stop, and report underload malfunction, but don’t send malfunction report to the indoor. The compressor stops for more than 3 minutes, Tpg_indoor> ice_temp_3+2ć, the compressor recovers. 5.2.6.6 The frequency limitation of modification rate In the field which is controlled by high frequency, if the modification rate is not high enough, the control-driven on chip will enter into weak magnetic control, this will help to relieve the problem of modification rate. If during the course of weak magnetic control, the modification rate is still not high enough, enter into the control of decreasing frequency until the alarm of modification rate is relieved. 5.2.6.8 Temperature protection of the outdoor refrigerating coil When the defrosting temperature and the sensor’s temperature are higher than 65ć, the frequency of the compressor decreases 1hz/10seconds. Keep the frequency until it decreases to the lowest frequency. When the temperatures are lower than 65ć and higher than 60ć, keep the frequency of the compressor. When the temperatures are lower than 60ć, relieve the defrosting temperature protection. 27 Domestic Air Conditioner HSM18HEKC/HRAC03/R2(DB)HUM18HC03/R2(DB)-SM Function and control 5.2.6.9˖Malfunction display and malfunction handling a)ǃFor the complete appliance’s malfunctions˖Annex 2 If there’s malfunction with the outdoor unit, the light of the outdoor unit will flash and its frequency is 1HZ, the number of times is according to the table, when a round of flashing is finished, the light shoud be off for 5 seconds. b)ǃFor the units’ malfunctins˖Annex 1 If there’s malfunction with the units, this will not affect the run of the complete appliance, but this can be displayed by the malfunction light, the light flashing frequency is 0.5HZ, the number of times is according to the malfunction table of the indoor units. When a round of flashing is finished, the light shoud be off for 10 seconds. Then report according to the order : unit A→unit B→unit C→unit D, that is, if there’s malfunction with several units, then just report the indoor unit with the highest priority level. Among the unit malfunctions, the priority level of the communication malfunction is the highest, for others, that appears first will have the priority. Remarks: in 3 minutes when the compressor stops, the units’ malfunctions are not displayed; the complete appliance’s malfunctions are prior to the units’ malfunctions. Annex 1˖Malfunction codes of the whole unit Remarks: under the mode of refrigeration, the malfunctions of each unit’s thin pipe temperature sensor are not reported, under the mode of heating, the malfunctions of each unit’s thick pipe temperature sensor are not reported. 28 Domestic Air Conditioner HSM18HEKC/HRAC03/R2(DB)HUM18HC03/R2(DB)-SM Function and control 5.3 Value of Thermistor 5.3.1 intdoor Unit Room sensor and Pipe Sensor R25ć=10KΩ±3% B25ć/50ć=3700K±3% Temp.((ć)) Max.(KΩ) Normal(KΩ) Min.(KΩ) Tolerance(ć) -30 165.2170 147.9497 132.3678 -1.94 1.75 -29 155.5754 139.5600 125.0806 -1.93 1.74 -28 146.5609 131.7022 118.2434 -1.91 1.73 -27 138.1285 124.3392 111.8256 -1.89 1.71 -26 130.2371 117.4366 105.7989 -1.87 1.70 -25 122.8484 110.9627 100.1367 -1.85 1.69 -24 115.9272 104.8882 94.8149 -1.83 1.67 -23 109.4410 99.1858 89.8106 -1.81 1.66 -22 103.3598 93.8305 85.1031 -1.80 1.64 -21 97.6556 88.7989 80.6728 -1.78 1.63 -20 92.3028 84.0695 76.5017 -1.76 1.62 -19 87.2775 79.6222 72.5729 -1.74 1.60 -18 82.5577 75.4384 68.8710 -1.72 1.59 -17 78.1230 71.5010 65.3815 -1.70 1.57 -16 73.9543 67.7939 62.0907 -1.68 1.55 -15 70.0342 64.3023 58.9863 -1.66 1.54 -14 66.3463 61.0123 56.0565 -1.64 1.52 -13 62.8755 57.9110 53.2905 -1.62 1.51 -12 59.6076 54.9866 50.6781 -1.60 1.49 -11 56.5296 52.2278 48.2099 -1.58 1.47 -10 53.6294 49.6244 45.8771 -1.56 1.46 -9 50.8956 47.1666 43.6714 -1.54 1.44 -8 48.3178 44.8454 41.5851 -1.51 1.42 -7 45.8860 42.6525 39.6112 -1.49 1.40 -6 43.5912 40.5800 37.7429 -1.47 1.39 -5 41.4249 38.6207 35.9739 -1.45 1.37 -4 39.3792 36.7676 34.2983 -1.43 1.35 -3 37.4465 35.0144 32.7108 -1.41 1.33 -2 35.6202 33.3552 31.2062 -1.38 1.31 -1 33.8936 31.7844 29.7796 -1.36 1.29 0 32.2608 30.2968 28.4267 -1.34 1.28 1 30.7162 28.8875 27.1431 -1.32 1.26 2 29.2545 27.5519 25.9250 -1.29 1.24 3 27.8708 26.2858 24.7686 -1.27 1.22 4 26.5605 25.0851 23.6704 -1.25 1.20 5 25.3193 23.9462 22.6273 -1.23 1.18 6 24.1432 22.8656 21.6361 -1.20 1.16 7 23.0284 21.8398 20.6939 -1.18 1.14 29 Domestic Air Conditioner HSM18HEKC/HRAC03/R2(DB)HUM18HC03/R2(DB)-SM Function and control 8 21.9714 20.8659 19.7982 -1.15 1.12 9 20.9688 19.9409 18.9463 -1.13 1.09 10 20.0176 19.0621 18.1358 -1.11 1.07 11 19.1149 18.2270 17.3646 -1.08 1.05 12 18.2580 17.4331 16.6305 -1.06 1.03 13 17.4442 16.6782 15.9315 -1.03 1.01 14 16.6711 15.9601 15.2657 -1.01 0.99 15 15.9366 15.2770 14.6315 -0.98 0.96 16 15.2385 14.6268 14.0271 -0.96 0.94 17 14.5748 14.0079 13.4510 -0.93 0.92 18 13.9436 13.4185 12.9017 -0.91 0.90 19 13.3431 12.8572 12.3778 -0.88 0.87 20 12.7718 12.3223 11.8780 -0.86 0.85 21 12.2280 11.8126 11.4011 -0.83 0.83 22 11.7102 11.3267 10.9459 -0.81 0.80 23 11.2172 10.8634 10.5114 -0.78 0.78 24 10.7475 10.4216 10.0964 -0.75 0.75 25 10.3000 10.0000 9.7000 -0.75 0.75 26 9.8975 9.5974 9.2980 -0.76 0.76 27 9.5129 9.2132 8.9148 -0.80 0.80 28 9.1454 8.8465 8.5496 -0.84 0.83 29 8.7942 8.4964 8.2013 -0.87 0.86 30 8.4583 8.1621 7.8691 -0.91 0.90 31 8.1371 7.8428 7.5522 -0.95 0.93 32 7.8299 7.5377 7.2498 -0.98 0.97 33 7.5359 7.2461 6.9611 -1.02 1.00 34 7.2546 6.9673 6.6854 -1.06 1.04 35 6.9852 6.7008 6.4222 -1.10 1.07 36 6.7273 6.4459 6.1707 -1.13 1.11 37 6.4803 6.2021 5.9304 -1.17 1.14 38 6.2437 5.9687 5.7007 -1.21 1.18 39 6.0170 5.7454 5.4812 -1.25 1.22 40 5.7997 5.5316 5.2712 -1.29 1.25 41 5.5914 5.3269 5.0704 -1.33 1.29 42 5.3916 5.1308 4.8783 -1.37 1.33 43 5.2001 4.9430 4.6944 -1.41 1.36 44 5.0163 4.7630 4.5185 -1.45 1.40 45 4.8400 4.5905 4.3500 -1.49 1.44 46 4.6708 4.4252 4.1887 -1.53 1.47 47 4.5083 4.2666 4.0342 -1.57 1.51 48 4.3524 4.1145 3.8862 -1.61 1.55 49 4.2026 3.9686 3.7443 -1.65 1.59 50 4.0588 3.8287 3.6084 -1.70 1.62 51 3.9206 3.6943 3.4780 -1.74 1.66 52 3.7878 3.5654 3.3531 -1.78 1.70 30 Domestic Air Conditioner HSM18HEKC/HRAC03/R2(DB)HUM18HC03/R2(DB)-SM Function and control 53 3.6601 3.4416 3.2332 -1.82 1.74 54 3.5374 3.3227 3.1183 -1.87 1.78 55 3.4195 3.2085 3.0079 -1.91 1.82 56 3.3060 3.0989 2.9021 -1.95 1.85 57 3.1969 2.9935 2.8005 -2.00 1.89 58 3.0919 2.8922 2.7029 -2.04 1.93 59 2.9909 2.7948 2.6092 -2.08 1.97 60 2.8936 2.7012 2.5193 -2.13 2.01 61 2.8000 2.6112 2.4328 -2.17 2.05 62 2.7099 2.5246 2.3498 -2.22 2.09 63 2.6232 2.4413 2.2700 -2.26 2.13 64 2.5396 2.3611 2.1932 -2.31 2.17 65 2.4591 2.2840 2.1195 -2.36 2.21 66 2.3815 2.2098 2.0486 -2.40 2.25 67 2.3068 2.1383 1.9803 -2.45 2.29 68 2.2347 2.0695 1.9147 -2.49 2.34 69 2.1652 2.0032 1.8516 -2.54 2.38 70 2.0983 1.9393 1.7908 -2.59 2.42 71 2.0337 1.8778 1.7324 -2.63 2.46 72 1.9714 1.8186 1.6761 -2.68 2.50 73 1.9113 1.7614 1.6219 -2.73 2.54 74 1.8533 1.7064 1.5697 -2.78 2.58 75 1.7974 1.6533 1.5194 -2.83 2.63 76 1.7434 1.6021 1.4710 -2.88 2.67 77 1.6913 1.5528 1.4243 -2.92 2.71 78 1.6409 1.5051 1.3794 -2.97 2.75 79 1.5923 1.4592 1.3360 -3.02 2.80 80 1.5454 1.4149 1.2942 -3.07 2.84 81 1.5000 1.3721 1.2540 -3.12 2.88 82 1.4562 1.3308 1.2151 -3.17 2.93 83 1.4139 1.2910 1.1776 -3.22 2.97 84 1.3730 1.2525 1.1415 -3.27 3.01 85 1.3335 1.2153 1.1066 -3.32 3.06 86 1.2953 1.1794 1.0730 -3.38 3.10 87 1.2583 1.1448 1.0405 -3.43 3.15 88 1.2226 1.1113 1.0092 -3.48 3.19 89 1.1880 1.0789 0.9789 -3.53 3.24 90 1.1546 1.0476 0.9497 -3.58 3.28 91 1.1223 1.0174 0.9215 -3.64 3.33 92 1.0910 0.9882 0.8942 -3.69 3.37 93 1.0607 0.9599 0.8679 -3.74 3.42 94 1.0314 0.9326 0.8424 -3.80 3.46 95 1.0030 0.9061 0.8179 -3.85 3.51 96 0.9756 0.8806 0.7941 -3.90 3.55 97 0.9490 0.8558 0.7711 -3.96 3.60 31 Domestic Air Conditioner HSM18HEKC/HRAC03/R2(DB)HUM18HC03/R2(DB)-SM Function and control 98 0.9232 0.8319 0.7489 -4.01 3.64 99 0.8983 0.8088 0.7275 -4.07 3.69 100 0.8741 0.7863 0.7067 -4.12 3.74 101 0.8507 0.7646 0.6867 -4.18 3.78 102 0.8281 0.7436 0.6672 -4.23 3.83 103 0.8061 0.7233 0.6484 -4.29 3.88 104 0.7848 0.7036 0.6303 -4.34 3.92 105 0.7641 0.6845 0.6127 -4.40 3.97 106 0.7441 0.6661 0.5957 -4.46 4.02 107 0.7247 0.6482 0.5792 -4.51 4.07 108 0.7059 0.6308 0.5632 -4.57 4.12 109 0.6877 0.6140 0.5478 -4.63 4.16 110 0.6700 0.5977 0.5328 -4.69 4.21 111 0.6528 0.5820 0.5183 -4.74 4.26 112 0.6361 0.5667 0.5043 -4.80 4.31 113 0.6200 0.5518 0.4907 -4.86 4.36 114 0.6043 0.5374 0.4775 -4.92 4.41 115 0.5891 0.5235 0.4648 -4.98 4.45 116 0.5743 0.5100 0.4524 -5.04 4.50 117 0.5600 0.4968 0.4404 -5.10 4.55 118 0.5460 0.4841 0.4288 -5.16 4.60 119 0.5325 0.4717 0.4175 -5.22 4.65 120 0.5194 0.4597 0.4066 -5.28 4.70 5.3.2 Outdoor Unit Ambient Sensor, Defrosting Sensor, Pipe sensor R25ć=10KΩ±3% B25ć/50ć=3700K±3% Temp.(ć) Max.(KΩ) Normal(KΩ) Min.(KΩ) Tolerance(ć) -30 165.2170 147.9497 132.3678 -1.94 1.75 -29 155.5754 139.5600 125.0806 -1.93 1.74 -28 146.5609 131.7022 118.2434 -1.91 1.73 -27 138.1285 124.3392 111.8256 -1.89 1.71 -26 130.2371 117.4366 105.7989 -1.87 1.70 -25 122.8484 110.9627 100.1367 -1.85 1.69 -24 115.9272 104.8882 94.8149 -1.83 1.67 -23 109.4410 99.1858 89.8106 -1.81 1.66 -22 103.3598 93.8305 85.1031 -1.80 1.64 -21 97.6556 88.7989 80.6728 -1.78 1.63 -20 92.3028 84.0695 76.5017 -1.76 1.62 -19 87.2775 79.6222 72.5729 -1.74 1.60 -18 82.5577 75.4384 68.8710 -1.72 1.59 -17 78.1230 71.5010 65.3815 -1.70 1.57 -16 73.9543 67.7939 62.0907 -1.68 1.55 -15 70.0342 64.3023 58.9863 -1.66 1.54 -14 66.3463 61.0123 56.0565 -1.64 1.52 -13 62.8755 57.9110 53.2905 -1.62 1.51 32 Domestic Air Conditioner HSM18HEKC/HRAC03/R2(DB)HUM18HC03/R2(DB)-SM Function and control -12 59.6076 54.9866 50.6781 -1.60 1.49 -11 56.5296 52.2278 48.2099 -1.58 1.47 -10 53.6294 49.6244 45.8771 -1.56 1.46 -9 50.8956 47.1666 43.6714 -1.54 1.44 -8 48.3178 44.8454 41.5851 -1.51 1.42 -7 45.8860 42.6525 39.6112 -1.49 1.40 -6 43.5912 40.5800 37.7429 -1.47 1.39 -5 41.4249 38.6207 35.9739 -1.45 1.37 -4 39.3792 36.7676 34.2983 -1.43 1.35 -3 37.4465 35.0144 32.7108 -1.41 1.33 -2 35.6202 33.3552 31.2062 -1.38 1.31 -1 33.8936 31.7844 29.7796 -1.36 1.29 0 32.2608 30.2968 28.4267 -1.34 1.28 1 30.7162 28.8875 27.1431 -1.32 1.26 2 29.2545 27.5519 25.9250 -1.29 1.24 3 27.8708 26.2858 24.7686 -1.27 1.22 4 26.5605 25.0851 23.6704 -1.25 1.20 5 25.3193 23.9462 22.6273 -1.23 1.18 6 24.1432 22.8656 21.6361 -1.20 1.16 7 23.0284 21.8398 20.6939 -1.18 1.14 8 21.9714 20.8659 19.7982 -1.15 1.12 9 20.9688 19.9409 18.9463 -1.13 1.09 10 20.0176 19.0621 18.1358 -1.11 1.07 11 19.1149 18.2270 17.3646 -1.08 1.05 12 18.2580 17.4331 16.6305 -1.06 1.03 13 17.4442 16.6782 15.9315 -1.03 1.01 14 16.6711 15.9601 15.2657 -1.01 0.99 15 15.9366 15.2770 14.6315 -0.98 0.96 16 15.2385 14.6268 14.0271 -0.96 0.94 17 14.5748 14.0079 13.4510 -0.93 0.92 18 13.9436 13.4185 12.9017 -0.91 0.90 19 13.3431 12.8572 12.3778 -0.88 0.87 20 12.7718 12.3223 11.8780 -0.86 0.85 21 12.2280 11.8126 11.4011 -0.83 0.83 22 11.7102 11.3267 10.9459 -0.81 0.80 23 11.2172 10.8634 10.5114 -0.78 0.78 24 10.7475 10.4216 10.0964 -0.75 0.75 25 10.3000 10.0000 9.7000 -0.75 0.75 26 9.8975 9.5974 9.2980 -0.76 0.76 27 9.5129 9.2132 8.9148 -0.80 0.80 28 9.1454 8.8465 8.5496 -0.84 0.83 29 8.7942 8.4964 8.2013 -0.87 0.86 30 8.4583 8.1621 7.8691 -0.91 0.90 31 8.1371 7.8428 7.5522 -0.95 0.93 32 7.8299 7.5377 7.2498 -0.98 0.97 33 Domestic Air Conditioner HSM18HEKC/HRAC03/R2(DB)HUM18HC03/R2(DB)-SM Function and control 33 7.5359 7.2461 6.9611 -1.02 1.00 34 7.2546 6.9673 6.6854 -1.06 1.04 35 6.9852 6.7008 6.4222 -1.10 1.07 36 6.7273 6.4459 6.1707 -1.13 1.11 37 6.4803 6.2021 5.9304 -1.17 1.14 38 6.2437 5.9687 5.7007 -1.21 1.18 39 6.0170 5.7454 5.4812 -1.25 1.22 40 5.7997 5.5316 5.2712 -1.29 1.25 41 5.5914 5.3269 5.0704 -1.33 1.29 42 5.3916 5.1308 4.8783 -1.37 1.33 43 5.2001 4.9430 4.6944 -1.41 1.36 44 5.0163 4.7630 4.5185 -1.45 1.40 45 4.8400 4.5905 4.3500 -1.49 1.44 46 4.6708 4.4252 4.1887 -1.53 1.47 47 4.5083 4.2666 4.0342 -1.57 1.51 48 4.3524 4.1145 3.8862 -1.61 1.55 49 4.2026 3.9686 3.7443 -1.65 1.59 50 4.0588 3.8287 3.6084 -1.70 1.62 51 3.9206 3.6943 3.4780 -1.74 1.66 52 3.7878 3.5654 3.3531 -1.78 1.70 53 3.6601 3.4416 3.2332 -1.82 1.74 54 3.5374 3.3227 3.1183 -1.87 1.78 55 3.4195 3.2085 3.0079 -1.91 1.82 56 3.3060 3.0989 2.9021 -1.95 1.85 57 3.1969 2.9935 2.8005 -2.00 1.89 58 3.0919 2.8922 2.7029 -2.04 1.93 59 2.9909 2.7948 2.6092 -2.08 1.97 60 2.8936 2.7012 2.5193 -2.13 2.01 61 2.8000 2.6112 2.4328 -2.17 2.05 62 2.7099 2.5246 2.3498 -2.22 2.09 63 2.6232 2.4413 2.2700 -2.26 2.13 64 2.5396 2.3611 2.1932 -2.31 2.17 65 2.4591 2.2840 2.1195 -2.36 2.21 66 2.3815 2.2098 2.0486 -2.40 2.25 67 2.3068 2.1383 1.9803 -2.45 2.29 68 2.2347 2.0695 1.9147 -2.49 2.34 69 2.1652 2.0032 1.8516 -2.54 2.38 70 2.0983 1.9393 1.7908 -2.59 2.42 71 2.0337 1.8778 1.7324 -2.63 2.46 72 1.9714 1.8186 1.6761 -2.68 2.50 73 1.9113 1.7614 1.6219 -2.73 2.54 74 1.8533 1.7064 1.5697 -2.78 2.58 75 1.7974 1.6533 1.5194 -2.83 2.63 76 1.7434 1.6021 1.4710 -2.88 2.67 77 1.6913 1.5528 1.4243 -2.92 2.71 34 Domestic Air Conditioner HSM18HEKC/HRAC03/R2(DB)HUM18HC03/R2(DB)-SM Function and control 78 1.6409 1.5051 1.3794 -2.97 2.75 79 1.5923 1.4592 1.3360 -3.02 2.80 80 1.5454 1.4149 1.2942 -3.07 2.84 81 1.5000 1.3721 1.2540 -3.12 2.88 82 1.4562 1.3308 1.2151 -3.17 2.93 83 1.4139 1.2910 1.1776 -3.22 2.97 84 1.3730 1.2525 1.1415 -3.27 3.01 85 1.3335 1.2153 1.1066 -3.32 3.06 86 1.2953 1.1794 1.0730 -3.38 3.10 87 1.2583 1.1448 1.0405 -3.43 3.15 88 1.2226 1.1113 1.0092 -3.48 3.19 89 1.1880 1.0789 0.9789 -3.53 3.24 90 1.1546 1.0476 0.9497 -3.58 3.28 91 1.1223 1.0174 0.9215 -3.64 3.33 92 1.0910 0.9882 0.8942 -3.69 3.37 93 1.0607 0.9599 0.8679 -3.74 3.42 94 1.0314 0.9326 0.8424 -3.80 3.46 95 1.0030 0.9061 0.8179 -3.85 3.51 96 0.9756 0.8806 0.7941 -3.90 3.55 97 0.9490 0.8558 0.7711 -3.96 3.60 98 0.9232 0.8319 0.7489 -4.01 3.64 99 0.8983 0.8088 0.7275 -4.07 3.69 100 0.8741 0.7863 0.7067 -4.12 3.74 101 0.8507 0.7646 0.6867 -4.18 3.78 102 0.8281 0.7436 0.6672 -4.23 3.83 103 0.8061 0.7233 0.6484 -4.29 3.88 104 0.7848 0.7036 0.6303 -4.34 3.92 105 0.7641 0.6845 0.6127 -4.40 3.97 106 0.7441 0.6661 0.5957 -4.46 4.02 107 0.7247 0.6482 0.5792 -4.51 4.07 108 0.7059 0.6308 0.5632 -4.57 4.12 109 0.6877 0.6140 0.5478 -4.63 4.16 110 0.6700 0.5977 0.5328 -4.69 4.21 111 0.6528 0.5820 0.5183 -4.74 4.26 112 0.6361 0.5667 0.5043 -4.80 4.31 113 0.6200 0.5518 0.4907 -4.86 4.36 114 0.6043 0.5374 0.4775 -4.92 4.41 115 0.5891 0.5235 0.4648 -4.98 4.45 116 0.5743 0.5100 0.4524 -5.04 4.50 117 0.5600 0.4968 0.4404 -5.10 4.55 118 0.5460 0.4841 0.4288 -5.16 4.60 119 0.5325 0.4717 0.4175 -5.22 4.65 120 0.5194 0.4597 0.4066 -5.28 4.70 Discharging Sensor R80ć=50KΩ±3% 35 Domestic Air Conditioner HSM18HEKC/HRAC03/R2(DB)HUM18HC03/R2(DB)-SM Function and control B25/80ć=4450K±3% Tolerance(ć) Temp.((ć)) Max.(KΩ) Normal(KΩ) Min.(KΩ) -30 14646.0505 12061.7438 9924.4999 -2.96 2.45 -29 13654.1707 11267.8730 9290.2526 -2.95 2.44 -28 12735.8378 10531.3695 8700.6388 -2.93 2.44 -27 11885.1336 9847.7240 8152.2338 -2.92 2.43 -26 11096.6531 9212.8101 7641.8972 -2.91 2.42 -25 10365.4565 8622.8491 7166.7474 -2.90 2.42 -24 9687.0270 8074.3787 6724.1389 -2.88 2.41 -23 9057.2314 7564.2244 6311.6413 -2.87 2.41 -22 8472.2852 7089.4741 5927.0206 -2.86 2.40 -21 7928.7217 6647.4547 5568.2222 -2.84 2.39 -20 7423.3626 6235.7109 5233.3554 -2.83 2.39 -19 6953.2930 5851.9864 4920.6791 -2.82 2.38 -18 6515.8375 5494.2064 4628.5894 -2.80 2.37 -17 6108.5393 5160.4621 4355.6078 -2.79 2.37 -16 5729.1413 4848.9963 4100.3708 -2.77 2.36 -15 5375.5683 4558.1906 3861.6201 -2.76 2.35 -14 5045.9114 4286.5535 3638.1938 -2.75 2.34 -13 4738.4141 4032.7098 3429.0191 -2.73 2.34 -12 4451.4586 3795.3910 3233.1039 -2.72 2.33 -11 4183.5548 3573.4260 3049.5312 -2.70 2.32 -10 3933.3289 3365.7336 2877.4527 -2.69 2.31 -9 3699.5139 3171.3148 2716.0828 -2.67 2.30 -8 3480.9407 2989.2460 2564.6945 -2.66 2.29 -7 3276.5302 2818.6731 2422.6139 -2.64 2.28 -6 3085.2854 2658.8058 2289.2164 -2.63 2.28 -5 2906.2851 2508.9126 2163.9230 -2.61 2.27 -4 2738.6777 2368.3158 2046.1961 -2.60 2.26 -3 2581.6752 2236.3876 1935.5371 -2.58 2.25 -2 2434.5487 2112.5459 1831.4826 -2.56 2.24 -1 2296.6230 1996.2509 1733.6024 -2.55 2.23 0 2167.2730 1887.0018 1641.4966 -2.53 2.22 1 2045.9191 1784.3336 1554.7931 -2.52 2.21 2 1932.0242 1687.8144 1473.1460 -2.50 2.20 3 1825.0899 1597.0431 1396.2333 -2.48 2.19 4 1724.6540 1511.6468 1323.7551 -2.47 2.17 5 1630.2870 1431.2787 1255.4324 -2.45 2.16 6 1541.5904 1355.6163 1191.0048 -2.43 2.15 7 1458.1938 1284.3593 1130.2298 -2.41 2.14 8 1379.7528 1217.2282 1072.8813 -2.40 2.13 9 1305.9472 1153.9626 1018.7481 -2.38 2.12 10 1236.4792 1094.3200 967.6334 -2.36 2.11 11 1171.0715 1038.0743 919.3533 -2.35 2.09 12 1109.4661 985.0146 873.7359 -2.33 2.08 36 Domestic Air Conditioner HSM18HEKC/HRAC03/R2(DB)HUM18HC03/R2(DB)-SM Function and control 13 1051.4226 934.9440 830.6210 -2.31 2.07 14 996.7169 887.6792 789.8583 -2.29 2.06 15 945.1404 843.0486 751.3077 -2.27 2.04 16 896.4981 800.8922 714.8380 -2.26 2.03 17 850.6086 761.0603 680.3265 -2.24 2.02 18 807.3024 723.4134 647.6580 -2.22 2.00 19 766.4212 687.8205 616.7252 -2.20 1.99 20 727.8172 654.1596 587.4271 -2.18 1.98 21 691.3524 622.3161 559.6694 -2.16 1.96 22 656.8979 592.1831 533.3634 -2.14 1.95 23 624.3328 563.6604 508.4261 -2.12 1.93 24 593.5446 536.6540 484.7796 -2.10 1.92 25 564.4275 511.0760 462.3510 -2.09 1.90 26 536.9865 486.9352 441.1516 -2.07 1.89 27 511.0105 464.0500 421.0258 -2.05 1.87 28 486.4151 442.3499 401.9146 -2.03 1.86 29 463.1208 421.7683 383.7626 -2.01 1.84 30 441.0535 402.2430 366.5175 -1.99 1.83 31 420.1431 383.7151 350.1301 -1.97 1.81 32 400.3242 366.1295 334.5542 -1.95 1.80 33 381.5350 349.4341 319.7460 -1.93 1.78 34 363.7176 333.5801 305.6645 -1.90 1.76 35 346.8176 318.5216 292.2709 -1.88 1.75 36 330.7839 304.2151 279.5286 -1.86 1.73 37 315.5682 290.6199 267.4031 -1.84 1.71 38 301.1254 277.6976 255.8620 -1.82 1.70 39 287.4128 265.4119 244.8745 -1.80 1.68 40 274.3905 253.7288 234.4118 -1.78 1.66 41 262.0206 242.6161 224.4465 -1.76 1.64 42 250.2676 232.0436 214.9529 -1.74 1.63 43 239.0983 221.9825 205.9065 -1.71 1.61 44 228.4809 212.4060 197.2844 -1.69 1.59 45 218.3860 203.2887 189.0648 -1.67 1.57 46 208.7855 194.6066 181.2273 -1.65 1.55 47 199.6531 186.3369 173.7524 -1.63 1.54 48 190.9639 178.4584 166.6217 -1.60 1.52 49 182.6945 170.9508 159.8181 -1.58 1.50 50 174.8228 163.7951 153.3249 -1.56 1.48 51 167.3280 156.9733 147.1268 -1.53 1.46 52 160.1904 150.4683 141.2090 -1.51 1.44 53 153.3914 144.2641 135.5577 -1.49 1.42 54 146.9136 138.3454 130.1598 -1.47 1.40 55 140.7403 132.6980 125.0027 -1.44 1.38 56 134.8559 127.3081 120.0746 -1.42 1.36 57 129.2457 122.1630 115.3645 -1.40 1.34 37 Domestic Air Conditioner HSM18HEKC/HRAC03/R2(DB)HUM18HC03/R2(DB)-SM Function and control 58 123.8956 117.2504 110.8618 -1.37 1.32 59 118.7926 112.5589 106.5564 -1.35 1.30 60 113.9241 108.0776 102.4388 -1.32 1.28 61 109.2784 103.7961 98.5000 -1.30 1.26 62 104.8443 99.7046 94.7315 -1.28 1.23 63 100.6112 95.7939 91.1253 -1.25 1.21 64 96.5692 92.0553 87.6735 -1.23 1.19 65 92.7088 88.4805 84.3690 -1.20 1.17 66 89.0211 85.0614 81.2048 -1.18 1.15 67 85.4976 81.7908 78.1744 -1.15 1.12 68 82.1303 78.6615 75.2715 -1.13 1.10 69 78.9116 75.6668 72.4902 -1.10 1.08 70 75.8343 72.8004 69.8249 -1.08 1.06 71 72.8916 70.0561 67.2703 -1.05 1.03 72 70.0770 67.4283 64.8213 -1.03 1.01 73 67.3844 64.9115 62.4731 -1.00 0.99 74 64.8080 62.5006 60.2211 -0.98 0.96 75 62.3423 60.1906 58.0609 -0.95 0.94 76 59.9821 57.9770 55.9885 -0.92 0.92 77 57.7223 55.8552 53.9998 -0.90 0.89 78 55.5583 53.8210 52.0912 -0.87 0.87 79 53.4856 51.8706 50.2591 -0.85 0.84 80 51.5000 50.0000 48.5000 -0.85 0.84 81 49.7063 48.2057 46.7083 -0.85 0.85 82 47.9835 46.4842 44.9911 -0.89 0.89 83 46.3286 44.8323 43.3452 -0.93 0.92 84 44.7385 43.2468 41.7672 -0.96 0.95 85 43.2105 41.7248 40.2540 -1.00 0.99 86 41.7386 40.2604 38.7996 -1.03 1.02 87 40.3241 38.8545 37.4048 -1.07 1.06 88 38.9643 37.5045 36.0668 -1.11 1.09 89 37.6569 36.2078 34.7831 -1.14 1.13 90 36.3996 34.9622 33.5513 -1.18 1.16 91 35.1903 33.7653 32.3689 -1.22 1.19 92 34.0269 32.6151 31.2338 -1.26 1.23 93 32.9075 31.5096 30.1438 -1.30 1.27 94 31.8302 30.4467 29.0970 -1.33 1.30 95 30.7933 29.4246 28.0915 -1.37 1.34 96 29.7950 28.4417 27.1254 -1.41 1.37 97 28.8337 27.4961 26.1970 -1.45 1.41 98 27.9078 26.5864 25.3048 -1.49 1.44 99 27.0160 25.7110 24.4470 -1.53 1.48 100 26.1569 24.8685 23.6222 -1.57 1.52 101 25.3290 24.0574 22.8291 -1.61 1.55 102 24.5311 23.2765 22.0662 -1.65 1.59 38 Domestic Air Conditioner HSM18HEKC/HRAC03/R2(DB)HUM18HC03/R2(DB)-SM Function and control 103 23.7620 22.5245 21.3323 -1.69 1.63 104 23.0205 21.8002 20.6261 -1.73 1.66 105 22.3055 21.1025 19.9465 -1.77 1.70 106 21.6159 20.4303 19.2924 -1.81 1.74 107 20.9508 19.7825 18.6626 -1.85 1.77 108 20.3091 19.1582 18.0563 -1.89 1.81 109 19.6899 18.5564 17.4723 -1.93 1.85 110 19.0924 17.9761 16.9098 -1.98 1.89 111 18.5157 17.4166 16.3680 -2.02 1.93 112 17.9590 16.8769 15.8458 -2.06 1.96 113 17.4214 16.3564 15.3427 -2.10 2.00 114 16.9023 15.8542 14.8577 -2.15 2.04 115 16.4010 15.3696 14.3902 -2.19 2.08 116 15.9167 14.9020 13.9394 -2.23 2.12 117 15.4489 14.4506 13.5047 -2.27 2.16 118 14.9968 14.0149 13.0855 -2.32 2.19 119 14.5599 13.5942 12.6811 -2.36 2.23 120 14.1376 13.1879 12.2909 -2.41 2.27 121 13.7294 12.7955 11.9144 -2.45 2.31 122 13.3347 12.4165 11.5510 -2.50 2.35 123 12.9531 12.0503 11.2003 -2.54 2.39 124 12.5840 11.6965 10.8617 -2.58 2.43 125 12.2270 11.3545 10.5348 -2.63 2.47 126 11.8817 11.0240 10.2191 -2.68 2.51 127 11.5475 10.7046 9.9142 -2.72 2.55 128 11.2242 10.3957 9.6197 -2.77 2.59 129 10.9112 10.0970 9.3352 -2.81 2.63 130 10.6084 9.8082 9.0602 -2.86 2.67 131 10.3151 9.5288 8.7945 -2.91 2.71 132 10.0312 9.2586 8.5378 -2.95 2.75 133 9.7563 8.9971 8.2895 -3.00 2.80 134 9.4901 8.7441 8.0495 -3.05 2.84 135 9.2322 8.4993 7.8175 -3.09 2.88 136 8.9824 8.2623 7.5931 -3.14 2.92 137 8.7404 8.0329 7.3760 -3.19 2.96 138 8.5059 7.8108 7.1660 -3.24 3.00 139 8.2787 7.5958 6.9629 -3.29 3.04 140 8.0584 7.3875 6.7664 -3.33 3.09 39 Domestic Air Conditioner HSM18HEKC/HRAC03/R2(DB) HUM18HC03/R2(DB) -SM 6.2.1 The Instruction of HSM18HEKC03/R2(DB)HUM18HC03/R2(DB) 40 HSM18HEKC/HRAC03/R2(DB) HUM18HC03/R2(DB) -SM Parts and Functions Indoor Unit Remote controller Inlet Air Purifying Filter 1 6 (inside) 2 7 Inlet grille 3 Outlet 4 8 5 9 10 Vertical blade Horizontal flap Emergency Switch (adjust left and right air fl ow) 20 12 21 Display board (adjust up and down air flow Don't adjust it manually) 19 11 13 22 14 Please be subject to the actual produce purchased the above picture is just from your reference 23 15 24 16 25 Display board 1 2 17 3 4 5 26 18 1. Mode display Operation mode SMART AUTO COOL DRY HEAT Remote controller 4 TIMER ON\OFF display 1 Signal receiver hole TIMER ON-OFF display 2 ON/OFF display SLEEP display 3 Ambient temp.display Note to the power failure resume: When receiving the remote control signal, display the set temperature and in the rest time the room temperature is displayed and this room temperature is only for reference. LO MED HI 5. LOCK display 6. TIMER OFF display TIMER ON display 5 COOL\HEAT\Dry\AUTO display Outdoor Unit Control the lightening and extinguishing of the indoor LED display board. 19. POWER ON/OFF button 20. DRY button 21. TEMP button 22. SWING button 23. HOUR button 24. EXTRA FUNCTION button Used to confirm timer and clock settings. 26. RESET button When the remote controller appears abnormal, use a sharp pointed article to press this button to reset the remote 1 Remove the battery cover; 2 Load the batteries as illustrated. 4 INLET 18. LIGHT button Loading of the battery OUTLET Used to lock buttons and LCD display. 25.CANCEL/CONFIRM button 2. Signal sending display 3. SWING display 4. FAN SPEED display press the sleep button ten times in five seconds and enter function after hearing four sounds.And press the sleep button ten times within five seconds and leave this function after hearing two sounds. FAN 7.TEMP display 8.POWER/SOFT display 9.HEALTH display 10. QUIET button 11. HEAT button 12. COOL button 13. AUTO button 14. FAN button 15. TIMER button 16. HEALTH button 17. LOCK button CONNECTING PIPING AND ELECTRICAL WIRING DRAIN HOSE Please be subject to the actual produce purchased the above picture is just from your reference 4 2 R-03 batteries, resetting key (cylinder); 3 Be sure that the loading is in line with the" + "/"-"; Load the battery,then put on the cover again. Note: The distance between the signal transmission head and the receiver hole should be within 7m without any obstacle as well. When electronic-sta rted type fluorescent lamp or change- over type fluorescent lamp or wireless telephone is installed in the room, the recei ver is apt to be disturbed in receiving the signals, so the distance to the indoor unit should be shorter. Full display or unclear display during operation indicates the batteries have been used up. Please change batteries. If the remote controller can't run normally during operation, please remove the batteries and reload several minutes later. Hint: Remove the batteries in case won't be in use for a long period. If there is any display after taking-out, just press reset key. 41 HSM18HEKC/HRAC03/R2(DB) HUM18HC03/R2(DB) -SM Operation Base Operation Emergency operation and test operation Emergency Operation: Use this operation only when the remote controller is defective or lost, and with function of emergency running, air conditoner can run automatically for a while. When the emergency operation switch is pressed, the " Pi " sound is heard once, which means the start of this operation. When power switch is turning on for the first time and emergency operation starts, the unit will run automatically in the following modes: Remote controller Room Designated Timer Fan Operation temperature temperature mode speed mode 23 C Below 23 C o o No AUTO COOL No AUTO HEAT i 26 C P o o Above 23 C emergency operation switch It is impossible to change the settings of temp. and fan speed,It is also not possible to operate in timer or dry mode. 1. Unit start Test operation: Press ON/OFF on the remote controller, unit starts. Test operation switch is the same as emergency switch. 2.Select temp.setting Use this switch in the test operation when the room o Press temperature is below 16 C, do not use it in the normal operation. button Every time the button is pressed, temp.setting increase 1oC,if kept depressed, it will increase rapidly Every time the button is pressed, temp.setting decrease 1oC,if kept depressed, it will decrease rapidly Select a desired temperature. Pi Under this operation mode,the fan motor of indoor unit will run in high speed. Air Flow Direction Adjustment Press FAN button. For each press, fan speed changes as follows: Remote controller: MED Pi operation starts with the air flow speed "Hi". 3.Fan speed selection LOW test operation switch Continue to press the test operation switch for more than 5 seconds . After you hear the "Pi" sound twice, release your finger from the switch: the cooling 1.Status display of air flow COOL/DRY: HI HEAT: Air conditioner is running under displayed fan speed. When FAN is set to AUTO, the air conditioner automatically adjusts the fan speed according to room temperature. Initial state 2.Left and right air flow adjustment(manual) Move the vertical blade by a knob on air conditioner to adjust left and right direction referring to Fig. Operation Mode AUTO Remote Controller Note Under the mode of auto operation, air conditioner will automatically select Cool or Heat operation according to room temperature When FAN is set to AUTO the air conditioner automatically adjusts the fan speed according to room temperature. Cautions: COOL DRY HEAT FAN ' When adjusting the flap by hand,turn off the unit. When humidity is high,condensate water might occur at air outlet if all vertical louvers are adjusted to left or right. It is advisable not to keep horizontal flap at downward position for a long time in COOLor DRY mode , otherwise, condensate water might occur. Note: When restart after remote turning off, the remote controller will automatically memorize the previous set swing position. In DRY mode , when room temperature becomes lower than temp.setting+2 o C, unit will run intermittently at LOW speed regardless of FAN setting. In HEAT mode, warm air will blow out after a short period of the time due to cold-draft prevention function. When FAN is set to AUTO, the air conditioner automatically adjusts the fan speed according to room temperature. In FAN operation mode , the unit will not operate in COOL or HEAT mode but only in FAN mode , AUTO is not available in FAN mode. And temp. setting is disabled. In FAN mode, sleep operation is not available. 42 HSM18HEKC/HRAC03/R2(DB) HUM18HC03/R2(DB) -SM Operation Sleep Operation Before going to bed,you can simply press the SLEEP button and unit will operate in SLEEP mode and bring you a sound sleep. 4. In FAN mode It has no SLEEP function. 5.Set the wind speed change when sleeping If the wind speed is high or middle before setting for the sleep, set for lowing the wind speed after sleeping. If it is low wind, no change. Note When TIMER function is set, the sleeping function can’t be set up .After the sleeping function is set up , if user resets TIMER function, the sleeping function will be cancelled; the machine will be in the state of timing-on. Use of SLEEP function After the unit starts,set the operation status,then press SLEEP button before which the clock must be adjudted and time being set. 1 hours after SLEEP mode starts,temp.will become 1OC higher than temp.setting.After another 1 hours,temp.rises by 1OC futher.The unit will run for further 6 hours then stops Temp. is higher than temp.setting so that room temperature won’t be too low for your sleep. SLEEP operation starts SLEEP operation stops Rises 1OC Rises 1OC Temp.setting high speed of AUTO fan mode. In HEAT mode, fan speed automatically takes medial speed of AUTO fan mode. (2) SOFT Operation You can use this function when silence is needed for rest or reading. In SOFT operation mode, fan speed automatically takes low speed of AUTO fan mode. Note ˖ During POWER operation, in rapid HEAT or COOL mode , the room will show inhomogeneous temperature distribution. Long period SOFT operation will cause effect of not too cool or not too warm. Approx.6hrs 1 hr (1) POWER Operation When you need rapid heating or cooling, you can use this function. In COOL mode, fan speed automatically takes Operation Mode 1. In COOL,DRY mode 1 hr POWER/SOFT Operation Unit stop In COOL, DRY mode To cancel POWER or SOFT operation Press POWER/SOFT button again ,POWER or SOFT disappears. HEALTH< Operation 2. In HEAT mode 1 hours after SLEEP mode starts,temp will become 2OC lower than temp.setting.After another 1 hours,temp decrease by 2 OC futher.After more another 3 hours,temp. rises by 1OC futher.The unit will run for further 3 hours then stops.Temp.is lower than temp. setting so that room temperature won’t be too high for your sleep. Temp.setting 1 hr Unit stop Healthy Negative ions Decreases 2OC 1 hr Decreases 2OC 3 hrs 3 hrs Rises 1OC SLEEP operation stops SLEEP operation starts In HEAT mode 3. In AUTO mode The unit operaters in corresponding sleep mode adapted to the automatically selected operation mode. The anion generator in the airconditioner can generate a lot of anion effectively balance the quantity of position and anion in the air and also to kill bacteria and speed up the dust sediment in the room and finally clean the air in the room. About UV light degerming function UV light emitted by the UV light device of the indoor unit catalytically activates the nano TiO2 on the multi-lights touching intermediary, and the degerming effect is highly efficient and lasting. Note: when the function is running, don't open the inlet grille. 43 HSM18HEKC/HRAC03/R2(DB) HUM18HC03/R2(DB) -SM EUROPEAN REGULATIONS CONFORMITY FOR THE MODELS Operation CE Timer On/Off On-Off Operation All the products are in conformity with the following European provision: - Low Voltage Directive 73/23/EEC - Low Voltage Directive 2006/95/EC -Electomagnetic CompatibilitY 89/336/EEC -Electomagnetic CompatibilitY 2004/108/EC Set clock correctly before starting TIMER operation. 1.After unit starts, select your desired operation mode. 2.Press TIMER button to change TIMER mode. Every time the button is pressed, display changes as follows: Remote controller: ROHS The products are fulfilled with the requirements in the directive 2002/95/EEC of the European parliament and of council on the Restriction of the use of Certain Hazardous Substances in Electrical and Electronic Equipment (EU RoHS Directive) BLANK TIMER ON TIMER OFF TIMER ON-OFF TIMER OFF-ON Then select your desired TIMER mode (TIMER ON or TIMER OFF or TIMER ON-OFF). " "or " "will flash. 3.Press TIME+ /TIME- button to set time. It can be adjusted within 24 hours. 4.After setting correct time, press SET button to confirm " "or" " on the remote controller stops flashing. 5.Cancel TIMER mode Just press TIMER button several times until TIMER mode disappears. Hints: After replacing batteries or a power failure happens, time setting should be reset. Remote controller possesses memory function,when use TIMER mode next time, just press SET button after mode selecting if time setting is the same as previous one. According to the Time setting sequence of TIMER ON or TIMER OFF, either Start-Stop or Stop-Start can be achieved. WEEE In accordance with the directive 2002/96/CE of the European parliament, herewith we inform the consumer about the disposal requirements of the electrical and electronic products. DISPOSAL REQUIREMENTS: Your air conditioning product is marked with this symbol.This means that electrical and electronic products shall not be mixed with unsorted household waste. Do not try to dismantle the system yourself : the dismantling of the air conditioning system,treatment of the refrigerant, of oil and of other part must be done by a qualified installer in accordance with relevant local and national legislation. Air conditioners must be treated at a specialized treatment facility for reuse, recycling and recovery. By ensuring this product is disposed of correctly, you will help to prevent potential negative consequences for the environment and humen health. Please contact the installer or local authority for more information. Battery must be removed from the remote controller and disposed of separately in accordance with relevant local and nationl legislation. Healthy airflow Operation 1.Press ON/OFF to starting IMPORTANT INFORMATION REGARDING THE REFRIGERANT USED Setting the comfort work conditions. 2.The setting of healthy airflow function appears on the 1).Press the button of healthy airflow , display. Horizontal airflow sending. Avoid the airflow blows direct to the body. 2).Press the button of healthy airflow again, appears on Avoid the airflow Downward airflow sending. the display. blows direct to the body. 3.The cancel of the healthy airflow function Press the button of healthy airflow again, the unit goes on working under the condition before the setting of healthy airflow function. Notice: Do not direct the flap by hand. Otherwise, the grille will run incorrectly. If the grille is not run correctly, stop Contains fluorinated greenhouse gases covered by the Kyoto Protocol R410A 1= kg 2 2= kg 1+2= kg 1 F A B C D E This product contains fluorinated greenhouse gases covered by the Kyoto Protocol. Do not vent into the atmosphere. Refrigerant type:R410A GWP* value:1975 GWP=global warming potential Please fill in with indelible ink, •1 the factory refrigerant charge of the product •2 the additional refrigerant amount charged in the field and • 1+2 the total refrigerant charge on the refrigerant charge label supplied with the product. The filled out label must be adhered in the proximity of the product charging port (e.g. onto the inside of the stop value cover). A contains fluorinated greenhouse gases covered by the Kyoto Protocol B factory refrigerant charge of the product: see unit name plate C additional refrigerant amount charged in the field D total refrigerant charge E outdoor unit F refrigerant cylinder and manifold for charging for a minute and then start, adjusting by remote controller. Note: 1.After setting the healthy airflow function, the position grill is fixed. 2.In heating, it is better to select the mode. 3.In cooling, it is better to select the mode. 4.In cooling and dry, using the air conditioner for a long time under the high air humidity, condensate water may occur at the grille . 44 HSM18HEKC/HRAC03/R2(DB) HUM18HC03/R2(DB) -SM Maintenance For Smart Use of The Air Conditioner Setting of proper room temperature Remote Controller Do not block the air inlet or outlet Indoor Body Proper temperature wipe the air conditioner by using a soft and dry cloth.For serious stains, use a neutral detergent diluted with water.Wring the water out of the cloth before wiping,then wipe off the detergent completely. Do not usewater,wipe the controller with a dry cloth.Do not use glass cleaner or chemical cloth. Do not use the following for cleaning Use the timer effectively Close doors and windows during operation Gasoline,benzine, thinner or cleanser may damage the coating of the unit. Hot water over 40 O C(104O F) may cause discoloring or deformation. Air Filter cleaning During cooling operation prevent the penetration of direct sunlight with curtain or blind Open the inlet grille by pulling it upward. Remove the filter. Push up the filter's center tab slightly until it is released from the stopper, and remove the filter downward. If the unit is not to be used for a long time, turn off the power supply main switch. Clean the filter. Use the louvers effectively Use a vacuum cleaner to remove dust, or wash the filter with water.After washing, dry the filter completely in the shade. Attach the filter. Attach the filter correctly so that the "FRONT" indication is facing to the front.Make sure that the filter is completely fixed behind the stopper.If the right and left filters are not attached correctly, that may cause defects. OFF Once every two weeks Close the inlet grille. Replacement of Air Purifying Filter 1.Open the lnlet Grille 4.Attach the standard air filter Prop up the inlet grille by using a small device named grille-support which located in the right side of the indoor unit. (Necessary installation) ATTENTION: The white side of the photocatalyst air purifying filter face outside,and the black side face the unit The green side of the bacteria-killing medium air purifying filter face outside,and the white side face the unit. 2.Detach the standard air filter Slide the knob slightly upward to release the filter, then withdraw it. 5.Close the Inlet Grille Close the Grille surely NOTE: Detach old Air Purifying Filter The photocatalyst air purifying filter will be solarized in fixed time. In normal family, it will be solarized every 6 months. The bacteria-killing medium air purifying filter will be used for a long time,no need for replacement. But in the period of using them ,you should remove the dust frequently by using vacuum cleaner or flaping them lightly,otherwise , its performance will be affected. 3.Attach Air Purifying Filter Put air purifying filter appliances into the right and left filter frames. Please keep the bacteria-killing medium air purifying filter in the cool and dry conditions avoid long time directly sunshine when you stop using it,or its ability of sterilization will be reduced. 45 HSM18HEKC/HRAC03/R2(DB) HUM18HC03/R2(DB) -SM Cautions WARNING Please call Sales/Service Shop for the Installation. Do not attempt to install the air conditioner by yourself because improper works may cause electric shock, fire, water leakage. WARNING When abnormality such as burnt-small found, immediately stop the operation button and contact sales shop. Check proper installation of the drainage securely Use an exclusive power source with a circuit breaker STRICT ENFORCEMENT OFF Connect power supply cord to the outlet completely STRICT ENFORCEMENT Use the proper voltage STRICT STRICT ENFORCEMENT ENFORCEMENT Take care not to damage Do not use power supply the power supply cord. cord in a bundle. PROHIBITION PROHIBITION PROHIBITION Do not start or stop the operation by disconnecting the power supply cord and so on. 1.Do not use power supply cord extended or connected in halfway 2.Do not install in the place where there is any possibility of inflammable gas leakage around the unit. 3.Do not get the unit exposed to vapor or oil steam. PROHIBITION Do not insert objects into the air inlet or outlet. Do not channel the air flow directly at people, especially at infants or the aged. PROHIBITION Do not try to repair or reconstruct by yourself. Connect the earth cable. earthing PROHIBITION CAUTION Do not use for the purpose of storage of food, art work, precise equipment, breeding, or cultivation. PROHIBITION Do not install the unit near a fireplace or other heating apparatus. Take fresh air occasionally especially when gas appliance is running at the same time. STRICT ENFORCEMENT Check good condition of the installation stand PROHIBITION Do not place animals or plants in the direct path of the air flow Do not operate the switch with wet hand. PROHIBITION Do not pour water onto the unit for cleaning PROHIBITION PROHIBITION Do not place any objects on or climb on the unit. PROHIBITION PROHIBITION 46 Do not place flower vase or water containers on the top of the unit. PROHIBITION HSM18HEKC/HRAC03/R2(DB) HUM18HC03/R2(DB) -SM Trouble shooting Cautions Before asking for service, check the following first. Phenomenon The system does not restart immediately. Noise is heard Normal Performance inspection Smells are generated. Mist or steam are blown out. Cause or check points When unit is stopped, it won't restart immediately until 3 minutes have elapsed to protect the system. When the electric plug is pulled out and reinserted, the protection circuit will work for 3 minutes to protect the air conditioner. During unit operation or at stop, a swishing or gurgling noise may be heard.At first 2-3 minutes after unit start, this noise is more noticeable. (This noise is generated by refrigerant flowing in the system.) During unit operation, a cracking noise may be heard.This noise is generated by the casing expanding or shrinking because of temperature changes. Should there be a big noise from air flow in unit operation, air filter may be too dirty. This is because the system circulates smells from the interior air such as the smell of furniture, paint, cigarettes. Do not obstruct or cover the ventilation grille of the air conditoner.Do not put fingers or any other things into the inlet/outlet and swing louver. Do not allow children to play with the air conditioner.In no case should children be allowed to sit on the outdoor unit. Specifications The refrigerating circuit is leak-proof. The machine is adaptive in following situation 1.Applicable ambient temperature range: Indoor Cooling Maximum:D.B/W.B 32oC/23oC Minimum:D.B/W.B 21oC/15oC Maximum:D.B/W.B 43oC/26oC 18oC Maximum:D.B 27oC Minimum: D.B 0 oC Outdoor Minimum: D.B Indoor Heating Outdoor Maximum:D.B/W.B 24oC/18oC Minimum:D.B/W.B - 7 oC/-8oC o o Outdoor Maximum:D.B/W.B 24 C/18 C (INVERTER) Minimum:D.B -15oC 2. If the power supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similar qualified person. 3.If the fuse of indoor unit on PC board is broken,please change it with the type of T. 3.15A/ 250V. If the fuse of outdoor unit is broken,change it with the type of T.25A/250V During COOL or DRY operation, indoor unit may blow out mist. This is due to the sudden cooling of indoor air. 4. The wiring method should be in line with the local wiring standard. 5. After installation, the power plug should be easily reached. In dry mode, fan speed can’t be changed. In DRY mode, when room temperature becomes lower than temp. setting+2 oC,unit will run intermittently at LOW speed regardless of FAN setting. Poor cooling 7. The appliance is not intended for use by young children or infirm persons without supervision. 8. Young children should be supervised to ensure that they do not play with the appliance. Is power plug inserted? Is there a power failure? Is fuse blownout? Multiple check 6. The waste battery should be disposed properly. 9. Please employ the proper power plug, which fit into the power supply cord. Is the air filter dirty? Normally it should be cleaned every 15 days. Are there any obstacles before inlet and outlet? Is temperature set correctly? Are there some doors or windows left open? Is there any direct sunlight through the window during the cooling operation?(Use curtain) Are there too much heat sources or too many people in the room during cooling operation? 10. The power plug and connecting cable must have acquired the local attestation. 11.In order to protect the units,please turn off the A/C first, and at least 30 seconds later, cutting off the power. 47 Introduction HSM09/12HRAC03/R2(DB) HUM09/12HC03/R2(DB) -SM 6.2.2 The Instruction of HSM18HRAC03/R2(DB) HUM18HC03/R2(DB) Parts and Functions Indoor Unit Remote controller Inlet Air Purifying Filter 16 (inside) Inlet grille 17 15 9. ON/OFF button 10. TIMER ON display 11. FAN SPEED display 14 18 13 LOW 19 12 20 11 Outlet 21 22 Anion generator Emergency Switch Vertical blade (inside) Horizontal flap Display board SiJQal receiver hole TEMP display HEALTH display COOL display HEAT display 23 Operation mode 24 Remote controller AUTO COOL DRY FAN HEAT 25 27 Actual indoor unit may vary from the one shown in the manual, according to the product purchased. AUTO 26 Display board HI 17.Signal sending display 18. POWER/SOFT display 19. TEMP display 28 20. TIMER OFF display 29 2 21. CLOCK display 30 22. TEMP button 23. FAN button 24.SWING button 1.CODE . HEALTH AIRFLOW button Used to select CODE A or B 25. FRESH button 26. which will be displayed on LCD.Please select A without 27. SET button special explanation. 28. POWER/SOFT button 29. LOCK button 2.LIGHT button If pressed, the other buttons Control the lightening and will be disabled.Press it once extinguishing of the indoor again,lock will be cancelled. LED display board. 3. TIMER button 30. RESET button 4. CLOCK button When the remote controller 5. SLEEP button appears abnormal,use a 6. MODE button sharp pointed article to press 7. HOUR button this button to reset the remote controller normal. 8. HEALTH button (adjust left and right air fl ow) (adjust up and down air flow Don't adjust it manually) MED 12. LOCK display 13. SWING display 14. SLEEP display 15. HEALTH display 16. Operation mode display (If the unit which you purchased has healthy function,follow it. If not,please ignore.) Dry display TIMER OFF display TIMER ON display SLEEP display The following functions and related displays are not available: LIGHT button is not available for HSU-09HRA103/R2 and HSU-12HRA103/R2. Outdoor Unit 1 26 Loading of the battery 1 Remove the battery cover; 2 Load the batteries as illustrated. OUTLET INLET CONNECTING PIPING AND ELECTRICAL WIRING DRAIN HOSE 2 R-03 batteries, resetting key (cylinder); 3 Be sure that the loading is in line with the " + "/"-"; 4 Load the battery,then put on the cover again. Clock set Note: The distance between the signal transmission head and the receiver hole should be within 7m without any obstacle as well. When electronic-started type fluorescent lamp or change-over type fluorescent lamp or wireless telephone is installed in the room, the receiver is apt to be disturbed in receiving the signals, so the distance to the indoor unit should be shorter. Full display or unclear display during operation indicates the batteries have been used up. Please change batteries. If the remote controller can't run normally during operation, please remove the batteries and reload several minutes later. Press CLOCK button, "AM" or "PM" flashes. Press or to set correct time. Each press will increase or decrease 1min. If the button is kept pressed,time will change quickly. After time setting is confirmed,press SET, "AM "and "PM" stop flashing,while clock starts working. Hint: Remove the batteries in case unit won't be in usage for a long period. If there are any display after taking-out, just need to press reset key. 48 Domestic air conditioner Introduction HSM09/12HRAC03/R2(DB) HUM09/12HC03/R2(DB) -SM EUROPEAN REGULATIONS CONFORMITY FOR THE MODELS Operation CE Timer On/Off On-Off Operation All the products are in conformity with the following European provision: - Low Voltage Directive 73/23/EEC - Low Voltage Directive 2006/95/EC -Electomagnetic CompatibilitY 89/336/EEC -Electomagnetic CompatibilitY 2004/108/EC Set clock correctly before starting TIMER operation. 1.After unit starts, select your desired operation mode. 2.Press TIMER button to change TIMER mode. Every time the button is pressed, display changes as follows: Remote controller: ROHS The products are fulfilled with the requirements in the directive 2002/95/EEC of the European parliament and of council on the Restriction of the use of Certain Hazardous Substances in Electrical and Electronic Equipment (EU RoHS Directive) BLANK TIMER ON TIMER OFF TIMER ON-OFF Then select your desired TIMER mode (TIMER ON or TIMER OFF or TIMER ON-OFF). " "or " "will flash. 3.Press TIME+ /TIME- button to set time. It can be adjusted within 24 hours. 4.After setting correct time, press SET button to confirm " "or" " on the remote controller stops flashing. 5.Cancel TIMER mode Just press TIMER button several times until TIMER mode disappears. Hints: After replacing batteries or a power failure happens, time setting should be reset. Remote controller possesses memory function,when use TIMER mode next time, just press SET button after mode selecting if time setting is the same as previous one. According to the Time setting sequence of TIMER ON or TIMER OFF, either Start-Stop or Stop-Start can be achieved. WEEE In accordance with the directive 2002/96/CE of the European parliament, herewith we inform the consumer about the disposal requirements of the electrical and electronic products. DISPOSAL REQUIREMENTS: Your air conditioning product is marked with this symbol.This means that electrical and electronic products shall not be mixed with unsorted household waste. Do not try to dismantle the system yourself : the dismantling of the air conditioning system,treatment of the refrigerant, of oil and of other part must be done by a qualified installer in accordance with relevant local and national legislation. Air conditioners must be treated at a specialized treatment facility for reuse, recycling and recovery. By ensuring this product is disposed of correctly, you will help to prevent potential negative consequences for the environment and humen health. Please contact the installer or local authority for more information. Battery must be removed from the remote controller and disposed of separately in accordance with relevant local and nationl legislation. 1.Press ON/OFF to starting IMPORTANT INFORMATION REGARDING THE REFRIGERANT USED Setting the comfort work conditions. 2.The setting of healthy airflow function appears on the 1).Press the button of healthy airflow , display. Horizontal airflow sending. Avoid the airflow blows direct to the body. 2).Press the button of healthy airflow again, appears on the display. Downward airflow sending. Avoid the airflow blows direct to the body. 3.The cancel of the healthy airflow function Press the button of healthy airflow again, the unit goes on working under the condition before the setting of healthy airflow function. Notice: Do not direct the flap by hand. Otherwise, the grille will run incorrectly. If the grille is not run correctly, stop Contains fluorinated greenhouse gases covered by the Kyoto Protocol R410A 1= kg 2 2= kg 1+2= kg 1 F A B C D E This product contains fluorinated greenhouse gases covered by the Kyoto Protocol. Do not vent into the atmosphere. Refrigerant type:R410A GWP* value:1975 GWP=global warming potential Please fill in with indelible ink, •1 the factory refrigerant charge of the product •2 the additional refrigerant amount charged in the field and • 1+2 the total refrigerant charge on the refrigerant charge label supplied with the product. The filled out label must be adhered in the proximity of the product charging port (e.g. onto the inside of the stop value cover). A contains fluorinated greenhouse gases covered by the Kyoto Protocol B factory refrigerant charge of the product: see unit name plate C additional refrigerant amount charged in the field D total refrigerant charge E outdoor unit F refrigerant cylinder and manifold for charging for a minute and then start, adjusting by remote controller. Note: 1.After setting the healthy airflow function, the position grill is fixed. 2.In heating, it is better to select the mode. 3.In cooling, it is better to select the mode. 4.In cooling and dry, using the air conditioner for a long time under the high air humidity, condensate water may occur at the grille . 49 Domestic air conditioner Introduction HSM09/12HRAC03/R2(DB) HUM09/12HC03/R2(DB) -SM Maintenance For Smart Use of The Air Conditioner Setting of proper room temperature Remote Controller Do not block the air inlet or outlet Proper temperature Do not usewater,wipe the controller with a dry cloth.Do not use glass cleaner or chemical cloth. Indoor Body wipe the air conditioner by using a soft and dry cloth.For serious stains, use a neutral detergent diluted with water.Wring the water out of the cloth before wiping,then wipe off the detergent completely. Do not use the following for cleaning Use the timer effectively Close doors and windows during operation Gasoline,benzine, thinner or cleanser ay damage the coating of the unit. Hot water over 40 O C(104O F) may discoloring or deformation. Air Filter cleaning During cooling operation prevent the penetration of direct sunlight with curtain or blind Open the inlet grille by pulling it upward. Remove the filter. Push up the filter's center tab slightly until it is from the stopper, and remove the filter downward. If the unit is not to be used for a long time, turn off the power supply main switch. Clean the filter. Use the louvers effectively Use a vacuum cleaner to remove dust, or wash the filter with water.After washing, dry the filter completely in the shade. Attach the filter. Attach the filter correctly so that the "FRONT" indication facing to the front.Make sure that the filter is fixed behind the stopper.If the right attached correctly, that OFF Once every two weeks Close the inlet grille. Replacement of Air Purifying Filter 1.Open the lnlet Grille 4.Attach the standard air filter Prop up the inlet grille by using a small device named grille-support which located in the right side of the indoor unit. (Necessary installation) ATTENTION: The white side of the photocatalyst air purifying filter face outside,and the black side face the unit The green side of the bacteria-killing medium air purifying filter face outside,and the white side face the unit. 2.Detach the standard air filter Slide the knob slightly upward to release the filter, then withdraw it. 5.Close the Inlet Grille Close the Grille surely NOTE: Detach old Air Purifying Filter The photocatalyst air purifying filter will be solarized in fixed time. In normal family, it will be solarized every 6 months. The bacteria-killing medium air purifying filter will be used for a long time,no need for replacement. But in the period of using them ,you should remove the dust frequently by using vacuum cleaner or flaping them lightly,otherwise , its performance will be affected. 3.Attach Air Purifying Filter Put air purifying filter appliances into the right and left filter frames. Please keep the bacteria-killing medium air purifying filter in the cool and dry conditions avoid long time directly sunshine when you stop using it,or its ability of sterilization will be reduced. 50 Domestic air conditioner Introduction HSM09/12HRAC03/R2(DB) HUM09/12HC03/R2(DB) -SM Cautions WARNING Please call Sales/Service Shop for the Installation. Do not attempt to install the air conditioner by yourself because improper works may cause electric shock, fire, water leakage. WARNING When abnormality such as burnt-small found, immediately stop the operation button and contact sales shop. Check proper installation of the drainage securely Use an exclusive power source with a circuit breaker STRICT ENFORCEMENT OFF Connect power supply cord to the outlet completely STRICT ENFORCEMENT Use the proper voltage STRICT STRICT ENFORCEMENT ENFORCEMENT Take care not to damage Do not use power supply the power supply cord. cord in a bundle. PROHIBITION PROHIBITION PROHIBITION Do not start or stop the operation by disconnecting the power supply cord and so on. 1.Do not use power supply cord extended or connected in halfway 2.Do not install in the place where there is any possibility of inflammable gas leakage around the unit. 3.Do not get the unit exposed to vapor or oil steam. PROHIBITION Do not insert objects into the air inlet or outlet. Do not channel the air flow directly at people, especially at infants or the aged. PROHIBITION Do not try to repair or reconstruct by yourself. Connect the earth cable. earthing PROHIBITION CAUTION Do not use for the purpose of storage of food, art work, precise equipment, breeding, or cultivation. PROHIBITION Do not install the unit near a fireplace or other heating apparatus. Take fresh air occasionally especially when gas appliance is running at the same time. STRICT ENFORCEMENT Check good condition of the installation stand PROHIBITION Do not place animals or plants in the direct path of the air flow Do not operate the switch with wet hand. PROHIBITION Do not pour water onto the unit for cleaning PROHIBITION PROHIBITION Do not place any objects on or climb on the unit. PROHIBITION PROHIBITION Do not place flower vase or water containers on the top of the unit. PROHIBITION 51 Domestic air conditioner Introduction HSM09/12HRAC03/R2(DB) HUM09/12HC03/R2(DB) -SM Trouble shooting Cautions Before asking for service, check the following first. Phenomenon The system does not restart immediately. Noise is heard Normal Performance inspection Smells are generated. Mist or steam are blown out. In dry mode, fan speed can’t be changed. Do not obstruct or cover the ventilation grille of the air conditoner.Do not put fingers or any other things into the inlet/outlet and swing louver. Cause or check points When unit is stopped, it won't restart immediately until 3 minutes have elapsed to protect the system. When the electric plug is pulled out and reinserted, the protection circuit will work for 3 minutes to protect the air conditioner. During unit operation or at stop, a swishing or gurgling noise may be heard.At first 2-3 minutes after unit start, this noise is more noticeable. (This noise is generated by refrigerant flowing in the system.) During unit operation, a cracking noise may be heard.This noise is generated by the casing expanding or shrinking because of temperature changes. Should there be a big noise from air flow in unit operation, air filter may be too dirty. This is because the system circulates smells from the interior air such as the smell of furniture, paint, cigarettes. Poor cooling Specifications The refrigerating circuit is leak-proof. The machine is adaptive in following situation 1.Applicable ambient temperature range: Indoor Cooling Maximum:D.B/W.B 32oC/23oC Minimum:D.B/W.B 21oC/15oC Maximum:D.B/W.B 43oC/26oC 18oC Maximum:D.B 27oC Minimum: D.B 0 oC Outdoor Minimum: D.B Indoor Heating Outdoor Maximum:D.B/W.B 24oC/18oC Minimum:D.B/W.B - 7 oC/-8oC o o Outdoor Maximum:D.B/W.B 24 C/18 C (INVERTER) Minimum:D.B -15oC 2. If the power supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similar qualified person. 3.If the fuse of indoor unit on PC board is broken,please change it with the type of T. 3.15A/ 250V. If the fuse of outdoor unit is broken,change it with the type of T.25A/250V During COOL or DRY operation, indoor unit may blow out mist. This is due to the sudden cooling of indoor air. 4. The wiring method should be in line with the local wiring standard. In DRY mode, when room temperature becomes lower than temp. setting+2 oC,unit will run intermittently at LOW speed regardless of FAN setting. Is power plug inserted? Is there a power failure? Is fuse blownout? Multiple check Do not allow children to play with the air conditioner.In no case should children be allowed to sit on the outdoor unit. 5. After installation, the power plug should be easily reached. 6. The waste battery should be disposed properly. 7. The appliance is not intended for use by young children or infirm persons without supervision. 8. Young children should be supervised to ensure that they do not play with the appliance. 9. Please employ the proper power plug, which fit into the power supply cord. Is the air filter dirty? Normally it should be cleaned every 15 days. Are there any obstacles before inlet and outlet? Is temperature set correctly? Are there some doors or windows left open? Is there any direct sunlight through the window during the cooling operation?(Use curtain) Are there too much heat sources or too many people in the room during cooling operation? 10. A breaker should be incorporated into fixed wiring. The breaker should be all-pole switch and the distance between its two contacts should be not less than 3mm. 11 .The power plug and connecting cable must have acquired the local attestation. 12.In order to protect the units,please turn off the A/C first, and at least 30 seconds later, cutting off the power. 13.Please don't insert any sensor on 3-way stop valve pipe fitting. HSU-09HRAC103/R2 HSU-12HRAC103/R2 HSU-18HRAC103/R2 X 0.415 0.317 0.085 52 Domestic air conditioner HSM18HEKC/HRAC03/R2(DB)HUM18HC03/R2(DB)-SM Service Diagnosis 7 Service Diagnosis 7.1 Caution for Diagnosis The operation lamp flashes when any of the following errors is detected. 1.When a protection device of the indoor or outdoor unit is activated or when the thermistor malfunctions, disabling equipment operation. 2.When a signal transmission error occurs between the indoor and outdoor units.In either case, conduct the diagnostic procedure described in the following pages. 7.2.Problem Symptoms and Measures Symptom None of the units operates Check Item Check the power supply. Details of Measure Check to make sure that the rated voltage is supplied. Check the indoor PCB Check to make sure that the indoor PCB is broken Operation Check the power supply. A power failure of 2 to 10 cycles can stop air conditioner sometimes stops. operation. Check for faulty operation Set the units to cooling operation, and compare the of the electronic Equipment operates but does expansion valve. not cool, or does not heat (only for heat pump) temperatures of the liquid side connection pipes of the Diagnosis by service port connection section among rooms to check the opening and closing operation of the electronic expansion valves of the individual units. Check for insufficient gas. pressure and operating current. Large operating noise and vibrations Check the installation condition. Check to make sure that the required spaces for installation (specified in the Technical Guide, etc.) are provided. 53 Domestic Air Conditioner HSM18HEKC/HRAC03/R2(DB)HUM18HC03/R2-SM Service Diagnosis 7.3 Error Codes and Description indoor display Code indication Indoor ˂ Outdoor Indoor Malfunction Indoor Outdoor (LED1 flash times) E7 15 E1 E2 E4 E14 F12 F1 / / / / 1 2 F3 4 F19 F27 F4 F8 F21 6 7 8 9 10 Communication fault between indoor and outdoor units Room temperature sensor failure Heat-exchange sensor failure Indoor EEPROM error Indoor fan motor malfunction Outdoor EEPROM error The protection of IPM Overcurrent protection of AC electricity for the outdoor model Communication fault between the IPM and outdoor PCB Power voltage is too high or low Compressor is lockrotor or stopt momentary Overheat protection for exhaust temperature Outdoor DC fan motor fault Frost-removing temperature sensor failure F7 11 Suction temperature sensor failure Page .55 F6 12 Ambient temperature sensor failure Page .55 F25 13 Exhaust temperature sensor failure Page .55 F11 18 deviate from the normal for the compressor Page .66 F28 19 Loop of the station detect error Page .66 F2 24 Overcurrent of the compressor Page .67 F23 25 F36 39 F22 Outdoor Malfunction Reference Page Description 3 Overcurrent protection for single-phase of the compressor Middle part of condenser temperature sensor failure Page .63 Page .55 Page .55 Page .62 Page .56 Page .62 Page .59 Page .67 Page .60 Page .65 ---Page .61 Page .58 Page .55 Page .67 ---- 54 Domestic Air Conditioner HSM18HEKC/HRAC03/R2(DB)HUM18HC03/R2-SM Service Diagnosis 7.3.1 Thermistor or Related Abnormality Indoor Display E1: Room temperature sensor failure E2: Heat-exchange sensor failure LED1 flash 10 times˖Defrost temperature sensor failure LED1 flash 11 times˖Suction temperature sensor failure LED1 flash 12 times˖Ambient temperature sensor failure LED1 flash 13 times˖Discharge temperature sensor failure Outdoor display Method of Malfunction Detection Malfunction Decision Conditions The temperatures detected by the thermistors are used to determine thermistors errors. When the thermistor input is more than 4.92V or less than 0.08V during compressor operation. z Note: The values vary slightly in some models Supposed Causes Ŷ Faulty connector connection Ŷ Faulty thermistor Ŷ Faulty PCB Troubleshooting * Caution Be sure to turn off power switch before connect or disconnect connector, else parts damage may be occurred. or Check the connector connection. NO Correct the connection Is it normal? Yes Thermistor resistance check NO Replace the thermistor Is it normal? Yes Replace the indoor unit PCB Thermistor resistance check method: Remove the connector of the thermistor on the PCB, and measure the resistance of thermistor using tester.The relationship between normal temperature and resistance is shown in the value of indoor thermistor. 55 Domestic Air Conditioner HSM18HEKC/HRAC03/R2(DB)HUM18HC03/R2-SM Service Diagnosis 7.3.2 Indoor fan motor malfunction Indoor Display E14 Method of The rotation speed detected by the Hall IC during fan motor operation is used to determine Malfunction abnormal fan motor operation Detection when the detected rotation feedback signal don’t received in 2 minutes Malfunction Decision Conditions Supposed Causes Ŷ Operation halt due to breaking of wire inside the fan motor. Ŷ Operation halt due to breaking of the fan motor lead wires. Ŷ Detection error due to faulty indoor unit PCB. How to check Fan Motor (DC) 1. Check connector connection. 2. Check motor power supply voltage output (pins 1-4). 3. Check motor control voltage (pins 4-5). 4. Check rotation command voltage output (pins 4-6). 5. Check rotation pulse input (pins 4-7). Notes: the a/c is electrifying, don’t pull out or insert the terminals of the motor, else the motor would be damaged. Troubleshooting * Caution Be sure to turn off power switch before connect or disconnect connector, or else parts damage may be occurred. 56 Domestic Air Conditioner HSM18HEKC/HRAC03/R2(DB)HUM18HC03/R2-SM Service Diagnosis Turn off power supply and rotate fan by hand NO Does fan rotate smoothly? Replace fan motor Yes Turn power ON and operate fan No Turn off power supply and disconnect fan motor connector, then turn power ON Does it rotate? Yes Check output of fan motor connector Is motor power voltage DC310V generated? Stop fan motor NO Replace indoor unit PCB Yes Is motor control power voltageDC15V generated? Is rotation number command pulse generated? Yes Yes Is rotation number command voltage DC1̚6V generated? NO Replace unit PCB indoor Yes Replace fan motor No No Replace indoor unit PCB Replace indoor fan motor PCB 57 Domestic Air Conditioner HSM18HEKC/HRAC03/R2(DB)HUM18HC03/R2-SM Service Diagnosis 7.3.3 Outdoor DC fan motor fault Check whether Terminal on the outdoor mainboard is well inserted. NO Is it normal? Reinsert the terminals YES Electrify the machine again and turn it on in the Cool state with the remote controller. check whether motor can run˛ NO Measure the voltage between 1 and 3 of the terminal of fan motor on the mainboard about DC310V,Measure the voltage between 3 and 4 of the terminal about DC15V. Measure the voltage between 5 and 3 of the terminal about 1-6v. YES Measure the voltage between 3 and 6 of the terminal about 0-5v. YES Is it normal? Is it normal? N0 YES The motor of the outdoor unit is damaged and needs replacing. N0 The mainboard of the outdoor unit is damaged and needs replacing 58 Domestic Air Conditioner HSM18HEKC/HRAC03/R2(DB)HUM18HC03/R2-SM Service Diagnosis 7.3.4 IPM protection Outdoor display LED1 flash 2 times. Indoor Display F1 Method of Malfunction Detection IPM protection is detected by checking the compressor running condition and so on. Malfunction Decision Conditions Ŷ The system leads to IPM protection due to over current. Ŷ The compressor faulty leads to IPM protection. Ŷ Circuit component of IPM is broken and led to IPM protection. Supposed Causes Ŷ IPM protection dues to the compressor faulty. Ŷ IPM protection dues to faulty PCB of IPM module. Ŷ Compressor wiring disconnected. Troubleshooting * Caution Be sure to turn off power switch before connect or disconnect connector, or else parts damage may be occurred. Turn off the power. check if the compressor wiring connected ok or not NO Disconnect the wiring Yes Check the IPM module NO Normal? Change the IPM module Yes Test the resistance values among Phases U, V and W of compressor If the resistance is 1ȍ or so NO Replace the compressor Yes Check the installation condition. Check the IPM module method: Disconnect the compressor harness connector from the outdoor unit PCB. To disengage the connector, press the protrusion on the connector. Then, measure resistance between P (+) and N (-) and the U, V and W terminals of the compressor connector with a multi-tester. Evaluate the measurement results for a pass/fail judgment. N(-)terminal of tester(P(+)for digital P(+) UVW P(-) UVW tester) P(+)terminal of tester(N(-)for digital UVW P(+) UVW P(-) tester) Normal resistance Several k to several M (и) Unacceptable resistance Short (0 ) or open 59 Domestic Air Conditioner HSM18HEKC/HRAC03/R2(DB)HUM18HC03/R2-SM Service Diagnosis 7.3.5 The communication fault between IPM and outdoor PCB Outdoor display LED1 flash 4 times Indoor Display F3 Method of Malfunction Detection Communication is detected by checking the IPM module and the outdoor PCB. Malfunction Decision Conditions Ŷ The outdoor PCB broken leads to communication fault Ŷ The IPM module broken leads to communication fault Supposed Causes Ŷ The outdoor PCB is broken Ŷ The IPM module is broken Ƶ Communication wiring disconnected Troubleshooting * Caution Be sure to turn off power switch before connect or disconnect connector, or else parts damage may be occurred. 1) Check whether Terminal CN23 and CN24 on the outdoor mainboard CN10 and CN11 on IPM module 2) Check whether the connected wire between IPM and outdoor NO Are they good? 1) Pull out and reinsert the terminals. 2) Replace connected wire Malfunction unsolved YES Electrify the machine again and turn it YES on, Check whether the voltage between 1 and 2 of Terminal CN23 is about DC5V, Check whether the Replace the outdoor IPM module with a new one. voltage between2 and 3 of Terminal CN23 is about DC15V, NO Replace the outdoor mainboard with a new one 60 Domestic Air Conditioner HSM18HEKC/HRAC03/R2(DB)HUM18HC03/R2-SM Service Diagnosis 7.3.6 Overheat Protection For Discharge Temperature Indoor display Outdoor display Method of Malfunction Detection F4 LED1 flash 8 times The exhaust temperature control is checked with the temperature being detected by the exhaust pipe thermistor. Malfunction Decision Conditions When the compressor discharge temperature is above 117ć Supposed Causes Ŷ Electronic expansion valve defective Ŷ Faulty thermistor. Ƶ Faulty PCB Troubleshooting * Caution Be sure to turn off power switch before connect or disconnect connector, or else parts damage may be occurred. Electrify the machine again and turn it on with the remote controller, then measure the temperature at the discharge temperature sensor of the compressor on the outdoor unit 1) The cryogen may have been leaked during YES The temperature exceeds 110 ć installation, or there may be leakage in the piping system. shortly after the 2) There may be other causes to make the machine starts up? discharge temperature too high. NO Malfunctions occur after running for some time even though the measured temperature is below 110ć. Pull out the discharge sensor and measure its resistance at standard temperatures according to the resistance-temperature table The results deviate YES much? The sensor is damaged. Replace the sensor with a new one. NO The outdoor mainboard is damaged and needs be replaced 61 Domestic Air Conditioner HSM18HEKC/HRAC03/R2(DB)HUM18HC03/R2-SM Service Diagnosis 7.3.7 EEPROM abnormal Indoor Display Method of Malfunction Detection E4 ˖Indoor EEPROM error F12˖Outdoor EEPROM error LED1 flash 1 times The Data detected by the EEPROM are used to determine MCU. Malfunction Decision Conditions When the Data of EEPROM is error or the EEPROM is damaged. Supposed Causes Ŷ Faulty EEPROM data Ŷ Faulty EEPROM Ŷ Faulty PCB Troubleshooting * Caution Be sure to turn off power switch before connect or disconnect connector, or parts damage may be occurred. Check the EEPROM of the indoor or outdoor mainboard, and be sure it is right. 62 Domestic Air Conditioner HSM18HEKC/HRAC03/R2(DB)HUM18HC03/R2-SM Service Diagnosis 7.3.8 Communication error between the indoor and outdoor units Indoor display Outdoor display E7 LED1 flash 15 times. Method of Malfunction Detection The date received from the another unit in indoor unit-outdoor unit signal transmission is checked whether is normal Malfunction Decision Conditions Supposed Causes When the date sent from the another unit cannot be received normally,or when the content of the data is abnormal Ŷ Indoor unit- outdoor unit signal transmission error due to wiring error Ŷ Faulty PCB Troubleshooting * Caution Be sure to turn off power switch before connect or disconnect connector, or else parts damage may be occurred. Yes Restart the a/c and it The outdoor mainboard needs becomes normally. dehumidification. NO If starting up normally, but NO malfunction occurs again The outdoor mainboard needs dedusting. after a while YES Check whether the linking cable No between the indoor and outdoor is 1. Reconnect the linking cable; well connected or whether its core 2. Replace the linking cable with wires are well insulated. new one. YES ˄A˅ 63 Domestic Air Conditioner HSM18HEKC/HRAC03/R2(DB)HUM18HC03/R2-SM Service Diagnosis ˄A˅ Yes Check the indoor mainboard. Measure the voltage between Jumpers 3 and 4 of IC1 on the indoor mainboard with a multimeter. No Test the outdoor power supply (230VAC and +310VDC) with a multimeter. If the voltage is of a constant value of 0V DCto5V DC If 230VAC is available but 310DC not, the power module is damaged, replace it with a new one. YES If both 230VAC and 310DC are The indoor mainboard is damaged; replace No available, measure it with a new one. +12V(from7805) is available. YES The outdoor mainboard is damaged; Replace them with a new one. Measure the AC voltage between positions 1 and 3 on the terminal of If the value is constant at about 30V, the outdoor unit with a multimeter. indoor mainboard is damaged, replace it with a new one. If the value varies between 0 and 80 VAC, the The outdoor mainboard is damaged; replace outdoor mainboard is damaged, replace it it with a new one. with a new one. 64 Domestic Air Conditioner NO HSM18HEKC/HRAC03/R2(DB)HUM18HC03/R2-SM Service Diagnosis 7.3.9 Power Supply over or under voltage fault F19 LED1 flash 6 times Indoor display Outdoor display: Method of Malfunction Detection An abnormal voltage rise or fall is detected by checking the specified voltage detection circuit. Malfunction Decision Conditions Supposed Causes An voltage signal is fed from the voltage detection circuit to the microcomputer Troubleshooting Ŷ Supply voltage not as specified. Ŷ The IPM module is broken. Ŷ The outdoor PCB is broken. * Caution Be sure to turn off power switch before connect or disconnect connector, or else parts damage may be occurred. Check the power supply No Is it rated power? This question may be caused by the power. Yes Check the IPM module No Is it normal? Change the new one Yes Change the outdoor PCB About how to check the IPM module, please refer to IPM protection fault. 65 Domestic Air Conditioner HSM18HEKC/HRAC03/R2(DB)HUM18HC03/R2-SM Service Diagnosis 7.3.10 Loop of the station detect error Outdoor Display LED1 flash 18 times Indoor Display F11 LED1 flash 19 times Indoor Display F28 Method of Malfunction Detection The position of the compressor rotor can not detected normally Malfunction Decision Conditions When the wiring of compressor is wrong or the connection is poor; or the compressor is damaged Ŷ Faulty The wiring of compressor Ŷ Faulty compressor Ƶ Faulty PCB Supposed Causes Troubleshooting * Caution Be sure to turn off power switch before connect or disconnect connector, or parts damage may be occurred. Within 3 minutes after the machine is supplied with power and turned on with the remote controller, the compressor could not start up YES 1. The wiring of compressor is incorrect or the connection is poor; 2. The compressor is damaged NO At first, the compressor start up ,soon the compressor stopped with the LED1 on the outdoor PCB blinks˄1Hz˅for 18/19 times YES IPM Module is damaged and needs replacing. Malfunction unso Malfunction unsolved The Malfunctions exist also. The compressor is damaged. Replace a new one 66 Domestic Air Conditioner HSM18HEKC/HRAC03/R2(DB)HUM18HC03/R2-SM Service Diagnosis 7.3.11 Over-current of the compressor Outdoor Display LED1 flash 3 LED1 flash 24 LED1 flash 25 Method of Malfunction Detection Indoor Display F22 Indoor Display F2 Indoor Display F23 The current of the compressor is too high Malfunction Decision Conditions When the IPM Module is damaged Or the compressor is damaged Power supply voltage is too low or too high. Ŷ Faulty IPM Module Ŷ Faulty compressor Ŷ Faulty power supply Supposed Causes Troubleshooting * Caution Be sure to turn off power switch before connect or disconnect connector, or parts damage may be occurred. Electrify the machine again and turn it on YES with the remote controller, If malfunctions are reported before or upon the IPM Module is damaged and needs replacing. compressor being started up NO The compressor is started normally, but malfunctions are reported after it YES Repair the power supply has run for some time. Check the power supply is too low or too high NO The system may have been over or under charged with gas, which can be judged through the pressure of the measuring system. 67 Domestic Air Conditioner Installation HSM18HEKC/HRAC03/R2(DB) HUM18HC03/R2(DB) -SM 8 Installation Installation Manual of Room Air Conditioner Preparation Necessary Tools for Installation ƽ ƽ ƽ ƽ ƽ ƽ Selection of Installation Place ƽ Torque wrench (17mm,22mm,26mm) ƽ Pipe cutter ƽ Flaring tool ƽ Knife ƽ Measuring tape ƽ Reamer Driver Nipper Hacksaw Hole core drill Spanner(17,19 and 26mm) Gas leakage detector or soap-and-water solution Indoor Unit ƽ Place, robust not causing vibration, where the body can be supported sufficiently. ƽ Place, not affected by heat or steam generated in the vicinity, where inlet and outlet of the unit are not disturbed. ƽ Place, possible to drain easily, where piping can be connected with the outdoor unit. ƽ Place, where cold air can be spread in a room entirely. ƽ Place, nearby a power receptacle, with enough space around. (Refer to drawings). ƽ Place where the distance of more than lm from televisions, radios, wireless apparatuses and fluorescent lamps can be left. Power Source ƽ In the case of fixing the remote controller on a wall, place where the indoor unit can ƽ Before inserting power plug into receptacle, check the voltage without fail. The power source is the same as the corresponding name plate. ƽ Install an exclusive branch circuit of the power. ƽ A receptacle shall be set up in a distance where the power cable can be reached.Do not extend the cable by cutting it. receive signals when the fluorescent lamps in the room are lightened. Outdoor Unit ƽ Place, which is less affected by rain or direct sunlight and is sufficiently ventilated. ƽ Place, possible to bear the unit, where vibration and noise are not increased. ƽ Place, where discharged wind and noise do not cause a nuisance to the neighbors. ƽ Place, where a distance marked n is available as illustrated in the above figure. Drawing for the installation of indoor and outdoor units The models adopt HFC free refrigerant R410A Attention must be paid to the rising up of drain hose more than 5cm Optional parts for piping A Non-adhesive tape B Adhesive tape C Saddle (L.S) with screws Connecting electric cable for indoor and outdoor E Drain hose F Heating insulating material G more than 10cm D G Piping hole cover Arrangement of piping directions more than 10cm F Rear left Floor fixing dimensions of the A Rear right Left outdoor unit (Unit:mm) Right C Below more than 10cm more than 10cm Fixing of outdoor unit ƽ Fix the unit to concrete or block ƽ The marks from A to G in the figure are the parts numbers. ƽ The distance between the indoor unit and the floor should be more than 2m. with bolts (10mm) and nuts firmly and horizontally. ƽ When fitting the unit to wall surface, roof or rooftop, fix D a supporter surely with nails or wires in consideration of E earthquake and strong wind. ƽ If vibration may affect the more than 60cm house, fix the unit by attaching a vibration-proof mat. more than15cm Please be subject to the actual product purchased , the above picture is just for your reference. Read this manual before installation Explain sufficiently the operating means to the user according to this manual. NO.0010531116 68 Domestic air conditioner Installation HSM18HEKC/HRAC03/R2(DB) HUM18HC03/R2(DB) -SM 1. Insert the drain hose into the dent of heat insulation materials of indoor unit. 2. Insert the indoor/outdoor electric cable from backside of indoor unit, and pull it out on the front side, then connect them. 3. Coat the flaring seal face with refrigerant oil and connect pipes. Cover the connection part with heat insulation materials closely, and make sure fixing with adhesive tape Accessory parts Remote controller (1) Drain hose (1) R-03 dry battery (2) Cushion (4) Mounting plate (1) Drain-elbow (1) Indoor/outdoor electric cable Plastic cap (4) Ø4X25 Screw (4) Heat insulation material Lid for right piping Pipe supporting plate (1) Lid for left piping Piping Pipe supporting plate Drain hose Lid for under piping pipe Selection of pipe Fix with adhesive tape Liquid pipe (Ø) 6.35mm(1/4”) Gas pipe (Ø) 12.7mm(1/2”) ● Indoor/outdoor electric cable and drain hose must be bound with refrigerant piping by protecting tape. [ Other direction piping ] ● Cut away, with a nipper, the lid for piping according to the piping direction and then bend the pipe according to theposition of wall hole. When bending, be careful not to crash pipes. ● Connect beforehand the indoor/outdoor electric cable, and then pull out the connected to the heat insulation of connecting part specially. NOTE˖The thickness of the pipe must be 0.8mm at least. Indoor unit 1 Fitting of the Mounting Plate and Positioning of the wall Hole Fixing the indoor unit body When the mounting plate is first fixed 1. Carry out, based on the neighboring pillars or lintels, a proper leveling for the plate to be fixed against the wall, then temporarily fasten the plate with one steel nail. 2. Make sure once more the proper level of the plate, by hanging a thread with a weight from the central top of the plate, then fasten securely the plate with the attachment steel nail. 3. Find the wall hole location A using a measuring tape ● Hang surely the unit body onto the upper notches of the mounting plate. Move the body from side to side to verify its secure fixing. ● In order to fix the body onto the mounting plate,hold up the body aslant from the underside and then put it down perpendicularly. Unloading of indoor unit body B= 60mm ● When you unload the indoor unit,please use your hand to arise the body to leave agraffe, then lift the bottom of the body outward slightly and lift the unit aslant until it leaves the mounting plate. 30mm A=145mm mounting plate B= 60mm 4 30mm A=150mm agraffe mounting plate Connecting the indoor/outdoor Electric Cable Removing the wiring cover When the mounting plate is fixed side bar and lintel ● Fix to side bar and lintel a mounting bar, Which is separately sold, and then fasten the plate to the fixed mounting bar. ● Remove terminal cover at right bottom corner of indoor unit, then take off wiring cover by removing its screws. ● Refer to the previous article, “ When the mounting plate is first fixed “, for the position of wall hole. 2 When connecting the cable after installing the indoor unit Making a Hole on the Wall and Fitting the Piping Hole Cover ● Make a hole of 60 mm in diameter, slightly descending to outside the wall. ● Install piping hole cover and seal it off with putty after installation Wall hole 1. Insert from outside the room cable into left side of the wall hole, in which the pipe has already existed. 2. Pull out the cable on the front side, and connect the cable making a loop. Ø60mm When connecting the cable before installing the indoor unit Indoor side (Section of wall hole) 3 ● ● Outdoor side Thickness of wall G Piping hole pipe ● Installation of the Indoor Unit ● Drawing of pipe Insert the cable from the back side of the unit, then pull it out on the front side. Loosen the screws and insert the cable ends fully into terminal block, then tighten the screws. Pull the cable slightly to make sure the cables have been properly inserted and tightened. After the cable connection, never fail to fasten the connected cable with the wiring cover. [ Rear piping ] ● Draw pipes and the drain hose, then fasten them with the adhesive tape [ Left· Left-rear piping ] ● In case of left side piping, cut away, with a nipper, the lid for left piping. ● In case of left-rear piping, bend the pipes according to the piping direction to the mark of hole for left-rear piping which is marked on heat insulation materials. Note When connecting the cable, confirm the terminal number of indoor and outdoor units carefully. If wiring is not correct, proper operation can not be carried out and will cause defect. 69 Domestic air conditioner Installation HSM18HEKC/HRAC03/R2(DB) HUM18HC03/R2(DB) -SM Outdoor unit Outdoor unit A 1(N) 2 (L) 3 (C) 4G0.75mm2 Installation of Outdoor Unit POWER HUM18HA03/R2(DB) HUM18HB03/R2(DB) Power cable: 1(N ) 2 (L) 3 (C ) Indoor unit A ^ Drawing for the installation of indoor and outdoor units Install according to Connection of pipes ƽ To bend a pipe, give the roundness as large as possible not to crush the pipe , and the bending radius should be 30 to 40 mm or longer. ƽ Connecting the pipe of gas side first makes working easier. ƽ The connection pipe is specialized for R410A. Half union Forced fastening without careful centering may damage the threads and cause a leakage of gas. Flare nut Pipe Diameter(ǿ) 3G2.5mm2 Spanner Outdoor unit A Fastening torque Liquid side6.35mm(1/4") 18N.m Liquid/Gas side9.52mm(3/8") 42 N.m Gas side 12.7mm(1/2") 55N.m Gas side 15.88mm(5/8") 60 N.m Torque wrench 1 2 Be careful that matters, such as wastes of sands, etc. shall not enter the pipe. The standard pipe length is 5m. If it is overm, the function of the unit will be affected. If the pipe has to be lengthened, the refrigerant should be charged, according to 20 g/m. But the charge of refrigerant must be conducted by professional air conditioner engineer. Before adding additional refrigerant, perform air purging from the refrigerant pipes and indoor unit using a vacuum pump,then charge additional refrigerant. 3(C) 4G0.75mm2 HUM18HC03/R2(DB)-EU Power cable: ^ ( ) CAUTION Outdoor unit ( ) 2N POWER 1L Indoor unit A Indoor unit B B A A Indoor unit Outdoor unit 3G2.5mm2 ● ● Outdoor unit Indoor unit B Oil trap Indoor unit L A N Outdoor unit ● ● Max.Elevation: Amax=15m In case the elevation A is more than 5m, oil trap shoud be installed every 5~7m Max. Length: Bmax=25m In case the pipe length B is more than 10m, the refrigerant should be charged, according to 20 g/m. 1 2 4G0.75mm 3(C) 2 Connection ƽ Use the same method on indoor unit. Loosen the screws on ƽ ( ) ƽ ( ) { ƽ 2N POWER 1L 1(N) 2(L) 3 HFM18HC03/R2(DB) Power cable: HUM18HC03/R2(DB)-EU terminal block and insert the plugs fully into terminal block, then tighten the screws. Insert the cable according to terminal number in the same manner as the indoor unit. If wiring is not correct, proper operation can not be carried out and controller may be damaged. Fix the cable with a clamp. Attaching Drain-Elbow ƽ If the drain-elbow is used, please attach it as figure. (Note: Only for heat pump unit.) 3G2.5mm2 1. If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similar qualified person. The type of connecting wire is Purging Method:To use vacuum pump 1. H05RN-F or H07RN-F. 2. If the fuse on PC board is broken please change it with the type of T. 3.15A/250V. Detach the service port’s cap of 3-way valve, the valve rod’s cap for 2-way valve and 3-way’s, connect the service port into the projection of charge hose (Iow) for gaugemanifold. Then connect the projection of charge hose (center) for gaugemanifold into vacuum pump. 2. Open the handle at Iow in gaugemanifold, operate vacuum pump. If the scalemoves of gause (Iow) reach vacuum condition in a moment, check 1. again. 3. The wiring method should be in line with the local wiring standard. 4. After installation, the power plug should be easily reached. 5. A breaker should be incorporated into fixed wiring. The breaker should be all-pole switch and the distance between its two contacts should be not less than 3mm. 3. Vacuumize for over 15min.And check the level gauge which should read -0.1MPa (76 cm Hg) at Iow pressure side. After the completion of vacuumizing, close the handle ‘Lo’ in gaugemanifold and stop the operation of the vacuum pump. Check condition of the scale and hold it for 1-2min. If the scale-moves back in spite of tightening, make flaring work again, the return to the beginning of 3 . 4. Open the valve rod for the 2-way valve to an angle of anticlockwise 90 degrees. After 6 seconds, close the 2-way valve and make the inspection of gas leakage. 70 Domestic air conditioner Installation HSM18HEKC/HRAC03/R2(DB) HUM18HC03/R2(DB) -SM 5. No gas leakage? In case of gas leakage, tighten parts of pipe connection. If leakage stops, then proceed 6. steps On Drainage ƽ Please install the drain hose so as to be downward slope without fail. ƽ Please don’t do the drainage as shown below. If it does not stop gas leakage, discharge whole refrigerants from the service port. After flaring work again and vacuumize, fill up prescribed refrigerant from the gas cylinder. Less than 5cm 6. Detach the charge hose from the service port, open 2-way valve and 3-way. Turn the valve rod anticlockwise until hitting lightly. leakage, turn the service port’s cap, the valve rod’s cap for 2-way valve and 3-way’s a little more than the point where the torque increases suddenly. 7.To prevent the gas 8. After attaching the each caps, check the gas It becomes The end is imm- It waves. The gap with the There is the bad high midway. ersed in water. ground is too small. smell from a ditch ƽ Please pour water in the drain pan of the indoor unit, and confirm that drainage leakage around the caps. is carried out surely to outdoor. ƽ In case that the attached drain hose is in a room, please apply heat insulation to it without fail. Step 1. Step 2. 2-way valve Liquid Side 3-way valve Gas Side Open Ƶ Refrigerant charge label Gaugemanifold(for R410A) Anti countercurrent joint Contains fluorinated greenhouse gases covered by the Kyoto Protocol Step 3. Close Tube(for R410A) Step 4. Vacuum pump(for R410A) Step 6. 2-way valve R410A 1= kg 2 2= kg 1+2= kg 1 2-way valve 3-way valve 3-way valve O Open 90 F 2-way valve 3-way valve Step 7. Valve rod cap Valve rod cap Service port cap CAUTION ƽ If the refrigerant of the air conditioner leaks, it is necessary to discharge all the refrigerant. Vacuumize first, then charge the liquid refrigerant into air conditioner according to the amount marked on the name plate. ƽ Please do not let other cooling medium, except specified one (R410A), or air enter into the cooling circulation system. Otherwise, there will be abnormal high pressure in the system to make it crack and lead to personal injuries. Power Source Installation ƽ The power source must be exclusively used for air conditioner. (Over I0A) ƽ In the case of installing an air conditioner in a moist place, please install an earth leakage breaker. ƽ For installation in other places, use a circuit breaker as far as possible. Check Items for Test Run Conventional flare tool Clutch-type clutch-type(Rigid-type) Wing-nut type (Imperial-type) 1.0~1.5mm 1.Cut pipe Flare tooling die 3.Insert the flare nut Correct D E Ƶ Please kindly explain to our customers how to operate through the instruction manual. be removed. Flare tool for R410A 0~0.5mm C Ƶ Check for Installation and Test Run Cutting and Flaring Work of Piping ƽ Pipe cutting is carried out with a pipe cutter and burs must ƽ After inserting the flare nut, flaring work is carried out. A B This product contains fluorinated greenhouse gases covered by the Kyoto Protocol. Do not vent into the atmosphere. Refrigerant type:R410A GWP* value:1975 GWP=global warming potential Please fill in with indelible ink, •1 the factory refrigerant charge of the product •2 the additional refrigerant amount charged in the field and • 1+2 the total refrigerant charge on the refrigerant charge label supplied with the product. The filled out label must be adhered in the proximity of the product charging port (e.g. onto the inside of the stop value cover). A contains fluorinated greenhouse gases covered by the Kyoto Protocol B factory refrigerant charge of the product: see unit name plate C additional refrigerant amount charged in the field D total refrigerant charge E outdoor unit F refrigerant cylinder and manifold for charging 2-way valve 3-way valve A Put check mark in boxes Gas leak from pipe connecting? Heat insulation of pipe connecting? Are the connecting wirings of indoor and outdoor firmly inserted to the terminal block? Is the connecting wiring of indoor and outdoor firmly fixed? Is drainage securely carried out? Is the earth line securely connected? Is the indoor unit securely fixed? Is power source voltage abided by the code? Is there any noise? Is the lamp normally lighting? Are cooling and heating (when in heat pump) performed normally? Is the operation of room temperature regulator normal? 1.5~2.0mm 2.Remove burs 4.Flare pipe Incorrect Lean Damage of flare Crack Partial Too outside Domestic air conditioner HSM18HEKC/HRAC03/R2(DB) HUM18HC03/R2(DB) -SM Removal of indoorunit (HSM18HEKC03/R2(DB)) 72 Removal Procedure HSM18HEKC/HRAC03/R2(DB) HUM18HC03/R2(DB)-SM 73 HSM18HEKC/HRAC03/R2(DB) HUM18HC03/R2(DB)-SM Removal Procedure Open the front panel until it is on the horizontal position, and then release the pivots on both sides of the unit to remove the front panel. Please close the panels before start the removal procedure of front grille. Slide the front panel from one side to another to release each axis. 74 HSM18HEKC/HRAC03/R2(DB) HUM18HC03/R2(DB)-SM two HOOKS three 75 Removal Procedure HSM18HEKC/HRAC03/R2(DB) HUM18HC03/R2(DB)-SM Removal Procedure flap flap flap flap 76 HSM18HEKC/HRAC03/R2(DB) HUM18HC03/R2(DB)-SM 77 Removal Procedure HSM18HEKC/HRAC03/R2(DB) HUM18HC03/R2(DB)-SM 78 Removal Procedure HSM18HEKC/HRAC03/R2(DB) HUM18HC03/R2(DB)-SM 79 Removal Procedure HSM18HEKC/HRAC03/R2(DB) HUM18HC03/R2(DB)-SM 80 Removal Procedure HSM18HEKC/HRAC03/R2(DB) HUM18HC03/R2(DB)-SM 81 Removal Procedure HSM18HEKC/HRAC03/R2(DB) HUM18HC03/R2(DB)-SM 82 Removal Procedure HSM18HEKC/HRAC03/R2(DB) HUM18HC03/R2(DB)-SM 83 Removal Procedure HSU-18HEKC/HRAC03/R2(DB)HUM18HC03/R2(DB)-SM Removal Procedure 9.2 The removal procedure of Indoor unit HSM18HRAC03/R2(DB) 9.2.1 Removal of Front Panel Procedure Step 1. Features Procedure Points 2. Remove the front panel 1 Hold the front panel by the tabs on the both sides and lift it until it 2 Open the front panel to the and left axes with Release the both sides pivots and insert them and remove the to the end. front panel. 84 Domestic Air Conditioner HSU-18HEKC/HRAC03/R2(DB)HUM18HC03/R2(DB)-SM Step 3 Pull the front panel Procedure Removal Procedure Points RXWKRUL]RQWDOO\ and remove it. 85 Domestic Air Conditioner HSU-18HEKC/HRAC03/R2(DB)HUM18HC03/R2(DB)-SM Removal Procedure 9.2.2 Removal of Air Filter Step Procedure /LIWDQDLU¿OWHU XSZDUGVVOLJKWO\ and then pull it Points Insert the air ¿OWHUVDORQJJURRYHV ZKHQLQVWDOOLQJ :KHQLQVWDOOLQJ LQVHUWKRRNVRIWKH out downwards. DLU¿OWHUFRPSOHWHO\ 86 Domestic Air Conditioner HSU-18HEKC/HRAC03/R2(DB)HUM18HC03/R2(DB)-SM Removal Procedure 9.2.3 Removal of the blade Step Procedure Release the PDUNHGKRRNV Points Insert the air ¿OWHUVDORQJJURRYHV ZKHQLQVWDOOLQJ Pull out and remove the blade. :KHQLQVWDOOLQJ LQVHUWKRRNVRIWKH DLU¿OWHUFRPSOHWHO\ 87 Domestic Air Conditioner HSU-18HEKC/HRAC03/R2(DB)HUM18HC03/R2(DB)-SM Removal Procedure 9.2.4 Removal of Front Case Step 1 2 Procedure Points Release the screw covers Loosen the 2 ¿[LQJVFUHZV 88 Domestic Air Conditioner HSU-18HEKC/HRAC03/R2(DB)HUM18HC03/R2(DB)-SM Step Procedure 3 Loosen the PDUNHGKRRNV 4 Pull out the front case. Removal Procedure Points 89 Domestic Air Conditioner HSU-18HEKC/HRAC03/R2(DB)HUM18HC03/R2(DB)-SM Removal Procedure 9.2.5 Removal of Vertical Blades and Display Board Step 1 Procedure Points Pull out the Vertical Blades. /RRVHQWKH¿[LQJ 2 screws,and remove the display board. Loosen the screw of 3 the drip proof plate. Lift and remove the electrical box. 90 Domestic Air Conditioner HSU-18HEKC/HRAC03/R2(DB)HUM18HC03/R2(DB)-SM Removal Procedure 9.2.6 Removal of Fan Drain pan and Electrical Box Step 1 2 Procedure Points Loosen the 2 screws. Pull out the drain pan. 'LVFKDUJHWKH static electricity 3 Loosen the screw of from your body the drip proof plate. Lift and remove EHIRUHWRXFKLQJWKH HOHFWULFDOSDUWVOLNH the electrical box. VLJQDOUHFHLYHU3&% It may cause the malfunction of PCB. 91 Domestic Air Conditioner HSU-18HEKC/HRAC03/R2(DB)HUM18HC03/R2(DB)-SM Removal Procedure 25HPRYDORI)DQ0RWRUDQG+HDW([FKDQJHU Step 1. Remove the Procedure Points ULJKWVLGHSODWH 1 Loosen the 2 screws. 2 Remove the ¿[LQJSODWH 3 Lift up the evaporator Be careful not to FXW\RXU¿QJHU E\WKH¿QVRIWKH evaporator. 3. Remove the fan. 1 Loosen the 2 screws. 92 Domestic Air Conditioner HSU-18HEKC/HRAC03/R2(DB)HUM18HC03/R2(DB)-SM Step 2 /LIWXSWKHULJKW Procedure Removal Procedure Points part of the fan motor and slide it WRWKHULJKWZDUGWR remove. 3 /LIWXSWKHULJKW part of the fan and remove it 93 Domestic Air Conditioner HSM18HEKC/HRAC03/R2(DB) HUM18HC03/R2(DB)-SM Removal of procedure 9.3 The removal procedure of outdoor 9.3.1 Removal of Outdoor panel Step 1. Features 1 Loosen the service Procedure Points Be careful not to cover screw and FXW\RXU¿QJHUE\ remove the service WKH¿QVRIWKHKHDW cover. H[FKDQJHU 94 Domestic air conditioner HSM18HEKC/HRAC03/R2(DB) HUM18HC03/R2(DB)-SM Step 2. Remove the panels. 1 Loosen the 4 screws and lift the top panel 2 Loosen the screws of the panel. 3 Pull and remove the front panel. Procedure Removal of procedure Points 95 Domestic air conditioner HSM18HEKC/HRAC03/R2(DB) HUM18HC03/R2(DB)-SM Removal of procedure 9.3.2 Romoval of Electrcal Box Step Procedure Points 5HPRYHWKH¿[LQJ screws, then lift the electrical box * * * * * * * 96 Domestic air conditioner HSM18HEKC/HRAC03/R2(DB) HUM18HC03/R2(DB)-SM Removal of procedure 9.3.3 Romoval of the Side panel Step 1 Procedure Points /RRVHQWKH¿[LQJ screws and remove the side panel. 97 Domestic air conditioner HSM18HEKC/HRAC03/R2(DB) HUM18HC03/R2(DB)-SM Step 2 3 Procedure Removal of procedure Points Remove the EDFNSDQHO /RRVHQWKH¿[LQJ screws and remove the side panel. 98 Domestic air conditioner HSM18HEKC/HRAC03/R2(DB) HUM18HC03/R2(DB)-SM Removal of procedure 9.3.4 Removal of fan and fan motor Step Procedure Points Put the lead wire Loosen the of motor when 1 remove the fan the propeller fan) 99 Domestic air conditioner HSM18HEKC/HRAC03/R2(DB) HUM18HC03/R2(DB)-SM Removal of procedure Step 2 Procedure Points screws and lift the fan motor. 100 Domestic air conditioner HSM18HEKC/HRAC03/R2(DB) HUM18HC03/R2(DB)-SM Step 3 Procedure Removal of procedure Points screws, then lift the 101 Domestic air conditioner HSM18HEKC/HRAC03/R2(DB) HUM18HC03/R2(DB)-SM Step 4 Procedure Removal of procedure Points screws, then lift the proof plate. 102 Domestic air conditioner HSM18HEKC/HRAC03/R2(DB) HUM18HC03/R2(DB)-SM Step Procedure Removal of procedure Points Cut down the 1 and pull out the compressor and remove the 103 Domestic air conditioner HSM18HEKC/HRAC03/R2(DB) HUM18HC03/R2(DB)-SM Step Procedure Removal of procedure Points 2 4 Domestic air conditioner HSM18HEKC/HRAC03/R2(DB) HUM18HC03/R2(DB)-SM Step 3 Procedure Removal of procedure Points /RRVHQWKH¿[LQJ KRRNDQGUHPRYH WKHKHDWH[FKDQJHU 105 Domestic air conditioner HSM18HEKC/HRAC03/R2(DB) HUM18HC03/R2(DB)-SM Step 4 Procedure Removal of procedure Points Remove the YDOYHEUDFNHW 106 Domestic air conditioner HSM18HEKC/HRAC03/R2(DB) HUM18HC03/R2(DB) -SM 10.Wiring Diagrams 10..1. Indoor unit Appendix Wring Diagram HSM18HEKC/HRAC03/R2(DB) HUM18HC03/R2(DB) -SM 10.2.Outdoor unit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˖<(//2:*5((1 Remark ˖the dotted parts are optional for different unit. 25˖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omestic air conditioner 32:(5 Wring Diagram HSM18HEKC/HRAC03/R2(DB) HUM18HC03/R2(DB) -SM 11.Circuit Diagrams 11.1.Indoor unit +5V R45 10K R46 1K C25 R55 R59 R62 R63 1K 100 R65 R66 100 100 REV SCK RCK SER GND +5V COM2 COM3 100 100 0.1UF +5V R301 10K R3 R4 2K 10K C10 IC1 R40 10K P1 2SA1037AK R1 10K R61 10K TXD RXD ZERO +5V C27 0.001uF C5 2 1 IRQ E5 +5V CN5 TJC8-02 0.1UF 100uF-16V R20 CN7 51K 3 2 1 R58 C16 1K 1 2 3 4 5 6 7 8 9 10 11 12 595 SER 13 595 RCK 14 595 SCK 15 GND 16 +5V 17 PG Feedback 18 PG output 19 20 21 22 0.001UF 10K +5V +12V R19 N5 10K 2SC2412 25 1 2 R21 27 R23 B2B-XH-A 10K R9 +5V B SW3 R18 XT1 JSS1270 R29 3.3K A R11 1M N4 2SC2412 4.7K R53 R110 10K 3 10K FCR8.0MC5 1 TJC8-02 RESET PTC0 PTC1 PTC2 PTC3 PTC4 PTC5 PTC6 PTE0/TXD PTE1/RXD IRQ PTD0/SS PTD1/MISO PTD2/MOSI PTD3/SPSCK VSS VDD PTD4/T1CH0 PTD5/T1CH1 PTD6/T2CH0 PTD7/T2CH1 PTB0/AD0 44 43 42 41 40 39 38 37 36 35 34 33 32 31 30 29 28 27 26 25 24 23 PTE4/OSC1 PTE3/OSC2 PTE2 VSSA VDDA PTA7/KBD7 PTA6/KBD6 PTA5/KBD5 PTA4/KBD4 PTA3/KBD3 PTA2/KBD2 PTA1/KBD1 PTA0/KBD0 VREFL VREFH PTB7/AD7 PTB6/AD6 PTB5/AD5 PTB4/AD4 PTB3/AD3 PTB2/AD2 PTB1/AD1 OSC1 OSC2 GND +5V E2 SCL E2 SDA +5V R30 R25 R26 10K 2 10K 3 1K4 R57 R56 5 1K6 1K7 8 IC4 DATA ULN2003 16 15 14 13 12 11 10 9 C20 +5V R28 1K GND +5V +5V B3P5-VH R33 R32 R31 R34 10K 10K 10K 10K +12v 0.1UF R67 L0 C19 CBB61-1.2uf-450VAC R64 120 -1W C22 3 2 1 TLP3526 10K R36 1K C12 0.1UF IC8 L1 +5V 171uH-800mA-1KHZ -LHB1308-171 CN12 4.7uF-16V E2 E3 4.7uF-16V 1 2 CN8 R35 1K 1K C13 R37 C14 0.01UF 0.01UF TJC8-02 0.01uf-50V 680 +12V MKP61-103-275V +5V R47 CN10 TJC8-02 5 4 3 2 1 +12V N CN2 CN9-1 S5B-PH 0.001UF C23 10K CN13 R22 0.01UF 35 JSS1270 R43 3.3K MC908GT16CFBE C15 B3B-EH-A +5V SW2 10K 560 2 1 XT1 R12 10K E2 CN11 C18 0.1UF 2K 0.1UF 8 7 6 5 2 C2 R2 A0 VCC A1 TEST A2 SCL VSS SDA AT24C02B B8B-PH +5V +5V 1 2 3 4 R68 C9 IC7 R10 8 7 6 5 4 3 2 1 +5V R302 10K 0.01UF 0.1UF CN6 SW1-1 JTP1288LA R16 1K C7 +5v 2 1 TSVC-1 1 SW1 4 3 2 1 R38 R27 4.7K 1% S4B-XH-A 4.7K 1% R303 BUZZ1 BEEP-PKM13EPY-4002 N L0 10K +12v CON2 D8 RLS4148 K2 892N-1AC-C R60 4.7K FLZ (L_IN) 1 CON1 1 +12V R24 R48 220 N7 2K 2SC2412 10K R71 R108 47K-2W R104 100K-1/4W +5V D101 R106 L ZD101 1N4746A(18V-1W) C102 0.047uF-50V R101 TXD 1K +5V 47K-2W 1N4007 IC101 PC851 N E101 100uF-50V R102 2K IC102 CON6 C103 2.2nf-250VAC 1K C101 0.001uF 1 R105 4.7K-1/4w TLP421 N CN3 1 2 3 S(N-W) 5289-2A 1 D102 R107 CON7 COM 2K-2W 1N4007 +5V +5V R17 R14 10K 4.7K R39 N2 2SC2412 L L0 FUSE1 T3.15A-250V AC N R201 R13 0.01UF 4.7K R202 4.7K 4.7K N3 2SC2412 C17 0.001UF C3 CN4 N MKP61-104-275V 3 2 1 B3B-XH-A +12V D5 IC3 D3 1N4007 D4 1N4007 +5V 3 1N4007 E4 D2 1N4007 D1 1N4007 MC7805CT 1 2 RV1 S14K350 1K 2K C8 NERTB-1.5-2P 2 CON3 10K 2 1 1 1 R15 CN1 ZERO R103 RXD C1 E1 2200uF-35V 0.1UF C4 470uF-16V 0.1UF 109 Domestic air conditioner Wring Diagram HSM18HEKC/HRAC03/R2(DB) HUM18HC03/R2(DB) -SM 11.2.Outdoor unit 11.2.1 Control Board Circuit Diagrams J24 J25 J26 J27 R3 1 2K/2W COM +5V CY7 222/250VAC GND 1 5V 2 RST 3 MODE 4 3 R98 10K 3 IC11 2 4 1 TLP851/PC851 J18 R4 2K 1 IC10 4 2 3 FLASH TLP421/PS2561 R47 R50 1K 5.1K/1% P1 2SA1037AK C20 102/50V CN33 2 White 1 R46 0 +5V R97 R51 10K 10K CN30 GND 1 PCJ35 2 HEAT 3 COOL 4 TEST/SS 5 K4 K6 1 1 5 4 3 2 1 CN13 9 8 7 6 5 4 3 2 1 CN12 1 2 1 1 2 1 3 2 1 1 CN10 K3 K1 K2 R88 +12V TQ(White) 47K/1% 1K 1K 1K 1K J17 Com with Module (Black) CN32 TEST/SS 1 GND 2 J32 K5 C C 2U/450V C1 2SC2412K N4 10K R87 4.7K J34 D6 12V-5A-892H(N)-1AC-C 12V-5A-892H(N)-1AC-C 12V-5A-892-1CC-C LL4148 CN17 12V-25A-891P-1A-C 12V-5A-892H(N)-1AC-C 12V-5A-892H(N)-1AC-C +5V +5V +5V 3 D11 D5 +12V+12V J6 J33 2 2SC2412K LL4148 P 2SC2412K LL4148 N5 J7 J15 1 N3 E11 N +15V+15V J23 J16 4.7U/16V C23 C24 C25 C26 J13 J4 J10 J14 J37 J8 CN18 104/50V R89 R85 R84 104/50V J12 J38 J3 104/50V 104/50V 3 R92 0 10K 10K 4.7K +5V 2 E12 Comment: 2SC2412K 0 +5V 1 R38 R93 4.7U/16V N1 0 C10 62 51 1K R83 R94 R91 VCC TX 0 330 61 52 CN19 1K R81 R99 VREF XQ 10K 53 104/50V 59 1K R79 R39 AVSS CS 2 R40 5.1K/1% J36 13 54 1K R77 10K DC-FANSPEED HW 1 E13 36 46 DC FAN PG Fre Adjust 4.7U/16V 41 31 J9 R41 1K J5 C14 Indoor Com OUT Fault Light CN20 38 55 R75 2K Indoor Com IN SW-1 102/50V 37 56 J22 3 PC COM SW-2 4.7K 45 60 2 E14 NC HEAT-2 R102 28 47 1 R86 4.7U/16V Terminal Pro Fan/E-Valve select 27 29 0 MODULE COMOUT SDA C19 26 30 104/50V N6 MODULE COM IN SCL J2 44 42 J21 +5V Comment: 2SC2412K NC H/L FAN SPEED R100 J1 CN31 24 57 R42 TEST-EN FAN 4.7K 50 58 VSS 4-WAY 1 330 23 63 R101 COOL-EN HEAT-1 2 R43 22 64 4.7K HEAT-EN PTC +5V 3 6 1 0 RESET E-VALVE-D 4 9 2 R104 XIN E-VALVE-C 7 4 XOUT E-VALVE-B 0 8 5 R44 J20 VSS E-VALVE-A 48 3 VSS MODE IC7 ULN2003 1K 49 43 C16 R103 VSS NC R66 1K 1 10 40 16 Comment: 102/50V VCC NC R67 1K 2 4.7K 15 14 39 NC NC CN16 R68 1K 3 15 35 14 NC NC D R69 1K 4 17 34 13 1 C NC NC R70 1K 5 12 2 18 33 B NC NC J39 R71 1K 19 32 6 11 3 NC NC J40 R72 A IC5 1K 20 16 7 10 4 +5V NC NC 21 12 +5V GND 12V 5 R5F212A8SNFA NC NC R61 25 11 6 NC NC C13 R95 R96 2K R59 104/50V 10K 10K +12V R62 2K 10K P2 R63 IC6 AT24C02B 2SA1037AK 560 SW1 5 4 R60 SDA GND 1 4 6 3 10K SCL GND 7 2 2 3 R64 GND GND 1 R65 8 VCC GND 10K 10K C12 +5V 104/50V 1 3 R52 10K R53 10K R54 10K R55 R56 R57 R58 +5V R48 10K R49 10K J19 CN23 5V 3 COM 2 GND 1 H XQ(Red) 4 2 1N4007 CY10 222/250VAC CN7 L HW(Yellow) CS(White) 2 PC817A 1 IC9 PC817A D1 C COM SW TEST(BLUE) 1 3 R37 330 CN4 C 20K/1% 4 IC8 R35 1K H E-valve(White) E9 47U/25V L 20K/1% R33 2.2K R36 1K White BlackCOM 20K/1% 103/50V C15 ( ) B FUSE2 T1A/250V R74 10K/1% C22 102/50V +15V R34 1K ZD2 10V/0.5W R13 330/1W ZD3 5.1V/0.5W CX7 104/275V W R80 CN21 310V 1 2 0V 3 15V 4 5 6 ST R82 N P R12 100/1W CX4 103/275V R78 RA-362M COM 400N R76 PE S14K350 8MH/10A J28 J29 J30 J31 PTC1 ERROR LED1 RV3 S14K350 CX3 225/275V Two-speed AC Fan CN14 CN15 R73 10K/1% C21 102/50V RV2 SA1 CX2 225/275V Three-speed AC Fan XT1 4M CN3 Yellow/Green 1 8MH/10A CY1 472/250V/275V AC-N CY2 472/250V/275V White 1 L2 R2 1M CY5 472/250V/275V CX1 225/275V COM heater Four -Way Comment: CN25 CN11 CN27 CN36 FUCTION TEST(White) 104/50V C11 R1 1M CY3 103/250V/275V RV1 S14K350 CY6 472/250V/275V L1 T25A 250VAC AC-L OUT CN9 1 1 FUSE1 Black 1 AC-L CN1 AC-N OUT CN8 CY4 103/250V/275V CN2 AC-L AC-N CN6 1 CN5 ZD1 IN5948B R25 D7 6 MBR1100\SB1100 1 10K FB 3 R29 E6 47 100U/16V GND 8 7 NC R18 47 6 NCP1200P100 R15 15 M1 C2 102/100V 222/250VAC 220 220 CN22 +15V 1 2 3 E4 470U/25V 5 R17 330/1W C6 104/50V E3 22U/25V 4 IC2 ( ) R32 5.1K/1% IRFUC20 2/1W CY9 D9 4 MUR115\MUR130\ER106 5 GNDDRV 10K L3 20UH/1A E5 470U/25V 7 CS VCC J11 4 R26 1K R27 IC1 ADJ HV 2 R90 0 C4 103/50V R16 +5VD R24 5.1K/1% E8 C9 Comment: 100U/16V 104/50V R21 CX5 104/275V Vout R20 3 D10 ER106 +5V 3 R28 5.1K/1% CY8 472/1KV L7805CV 2 R14 100K/2W 1 47 C3 IC4 +12V Comment: E22034 102/100V 1 T1 Vin D8 10 MBR3100\ER302 E7 C8 R22 470U/25V 104/50V 1K/0.5W 9 C7 104/50V P N R19 PC817A 3 1 2 R30 1K R31 1K C5 104/50V IC3 TL431C 110 Domestic air conditioner Wring Diagram HSM18HEKC/HRAC03/R2(DB) HUM18HC03/R2(DB) -SM CN26 P 1 250 Connector P R23 220K/2W E1 E2 CX6 105/275VAC 680U/400V/450V 680U/400V/450V LED2 POWER N 1 250 Connector CN24 N 11.2.2 Module Board Circuit Diagram L 5. 2MH/15A CN7 2 LO CN1 P D207 FFA30U60DN 24 P 1 3 IC8 C404 SGH40N60UF 474/275V C405 104/275V CN2 U 680U/400V*2 V 22 CN3 V W 21 CN4 W 6 R220 82 5 IC5 7 C208 104 HA17393AF 15V R230 D203 US1M C032 104 D202 US1M C034 104 D201 US1M C036 104 10 8 IC6 R207 1 R209 3 C201 104 4 HA1630D06 R211 1K 1K 1K 6 IC6 7 5 HA1630D06 R210 6. 8K 5V 1 2 3 4 5V 5V R202 6. 2K R205 1K 2 IC4 1 4 HA1630D06 R206 1K R201 1K 6 R203 1K 5 R204 6. 2K IC4 7 15V CN10 HA1630D06 C504 100U/25V 3 2 1 C501 100U/16V POWER(BLUE) 5V PC2 330 PC817A MMBT9013 TR3 3 2 1 C018 103 R016 1K R012 4. 7K R015 CN11 PC1 R014 C017 223 330 R013 C016 472 PC817A 8 7 6 5 R010 4. 7K 8 3 C202 104 IC3 24C04 C011 104 5V R019 4. 7K R018 4. 7K TR2 C014 MMBT9012 102 R229 4.22K R228130K R227130K R226130K 2 VNO VNC VN1 CIN FO UN WN VN WP VNC VP UP VWFB VVFB VP1 8 15V 9 10 11 12 13 14 15 16 17 R213 100 1 C203 104 R208 6. 8K R212 9. 1K 7 IC5 C204104 8 4 HA17393AF R011 4. 7K 6 D206 24V/1W C023 C413 100U/25V 5V R224 4. 7K 5 224 C205 223 R218 82 C207 104 4 2 5V C412 47U/25V C411 47U/25V C022 103 40 39 38 37 36 35 34 33 32 31 30 29 R231 4.7K 28 27 26 25 24 23 22 21 R221 140 3 R008 4. 7K 5V 5V C003 104 C002 104 C006 474 C004 104 41 R009 4. 7K 42 43 44 45 46 47 R006 100 R005 4. 7K 48 C020 49 102 50 C019 R017 4. 7K 51 103 52 53 54 C028 55 103 R007 4. 7K 56 57 CN12 58 59 RES 7 FWP 60 6 TXD 5 RXD 4 MD1 3 5V 2 GND 1 20 19 18 17 16 15 14 13 12 11C001 10 104 9 8 7 C015 6 102 5 4 3 2 1 C410 47U/25V D204 LL4148 IC1 SH7046 61 62 63 64 R001 4.7K 65 66 R002 4.7K 67 68 R004 4.7K 69 70 71 72 73 74 C008 75 76 474 77 C009 78 471 79 80 C502 100U/25V TR1 MMBT9013 3 R222 C005 104 5V C007 474 R216 10 2 R225 5V R003 4.7K 330 C012 104 5V C029 471 15V 8 IC7 6 TLP251 5 N C030 471 3 R217 1K 5V 2 20 0. 015/5W LL4148 4 RS2 N CN5 R214 100 VUFB 10K RS1 0. 015/5W D205 BG1 D25B X60B R223 C406 104/275V R215 CN9 AC -N communicate U 23 PM1 PS21965-AT R219 1K CN8 AC -L CN6 LI X1 10M IC2 T600D C013 104 4. 7U/16V C503 D208 LL4148 5V 330 111 Domestic air conditioner Appendix HSM18HEKC/HRAC03/R2(DB) HUM18HC03/R2(DB) -SM 12 Description of coding rules of unit model H 1 M S H 8 EKC 0 R 3 (D 2 B) DC Inverter Refrigerant type:R2(R410A) Applicable voltage:3(220~230V) Applicable frequency:0(50HZ) apparance of indoor unit is EKC series H-heat pump Nominal cooling capacity (18000 BTU/h) M-Multi match:one outdoor unit can match different indoor unit The structure code of indoor unit: S(wall-mounted) H-Abbreviation of Haier HSM18HRAC03/R2(DB) means 18000BTU. H U 1 M 8 H 0 C R 3 2 (D B) DC Inverter Refrigerant type:R2(R410A) Applicable voltage:3(220~230V) Applicable frequency:0(50HZ) C is serial number H-heat pump Nominal cooling capacity (18000BTU/h) M-Multi match:one outdoor unit can match different indoor unit The structure code of outdoor unit: H-Abbreviation of Haier HUM18HC03/R2(DB) means18000BTU. Examples: HSU-07RD03/R1,It represents wall-mounted split type heat pump a capacity is 7000BTU/h,and the power supply is 220-230V/50Hz,”D” ir condition er .The cooling means the developing sequence,and"R1" means the refrigerant is R407C. 112 Domestic Air Conditioner HSM18HEKC/HRAC03/R2(DB) HUM18HC03/R2(DB) -SM The end Sincere Forever Haier Group Zhao Ni Zhang Fei Yang Bifei 86 532 88936935 Wu Hongjin ">

Public link updated
The public link to your chat has been updated.
Advertisement
Key features
- Cooling, heating and dehumidifying modes
- Easy-to-use remote control
- DC inverter technology (EK series)
- Healthy negative ions (HUM18HC03/R2(DB) model)
- 24-hour timer
- Sleep mode
Frequently asked questions
This air conditioner offers cooling, heating, and dehumidifying modes. It also has a fan mode for circulating air without cooling or heating.
You can control the air conditioner using the remote control. The remote control allows you to adjust the temperature, fan speed, mode, and other settings.
DC inverter technology is used in the EK series models. It helps to save energy by efficiently controlling the compressor's speed.
The healthy negative ion feature is available in the HUM18HC03/R2(DB) model. Negative ions can help to purify the air by neutralizing pollutants and allergens.
Yes, this air conditioner has a 24-hour timer that allows you to set it to turn on or off at specific times.
The sleep mode optimizes the air conditioner's settings for comfortable sleep. It can adjust the temperature and fan speed to create a more restful environment.