TECHNICAL DATA
Power Supply:
9V battery or 9V transformer
Min Operating Water Pressure:
0.5 bar(7 PSI)
Max Operating Water Pressure:
8.0 bar(116 PSI) With water pressure of more
than 8 Bars, use a pressure reducing valve
Sensor Range:
Self adjusting sensor
Minimum Sensor Range:
50mm.
Maximum Sensor Range:
160 mm.
Security time:
90 seconds. Can be reduced with the remote
control
2 | Dolphin Blue | DB840 / DB845 / DB850 / DB875
TECHNICAL DATA
DB840
DB845
DB850
DB875
DB840 / DB845 / DB850 / DB875 | Dolphin Blue | 3
PACK CONTENTS
Familiarise yourself with the part names and confirm that the parts are included
DB840 / DB845
1 x Tap and attachments
1 x Tap and
with internal
attachments
battery
1 x Allen Key
1 x Allen Key
1 x filter
1 x filter
DB850 / DB875
1 x Tap and
1 x Tap and
attachments with
attachments
internal battery
1 x Allen Key
1 x Allen Key
2 x filters
2 x filters
4 | Dolphin Blue | DB840 / DB845 / DB850 / DB875
PRE INSTALLATION INFORMATION
CHECK CONTENTS
Separate all parts from packaging and check each part with the Pack contents
section. Pay attention to the different models variations.
Make sure all parts are accounted for before discarding any packaging material.
If any parts are missing, do not attempt to install this electronic tap until you
obtain the missing parts.
WARNINGS:
Do not install the tap facing a mirror or any other electronic system operated
by an infra-red sensor. To prevent reflection problems, it is recommended to keep
a minimum distance of 1.50 meters between the tap and other objects.
PREPARATION FOR INSTALLATION
Flush water supply lines thoroughly
before installing the tap. Do
not allow dirt, Teflon tape or metal
particles to enter the tap.
Shut off water supply.
IMPORTANT:
All plumbing is to be installed in
accordance with applicable codes
and regulations.
Recommended hole size
DB840 / DB845 / DB850 / DB875 | Dolphin Blue | 5
TAP INSTALLATION
STEP 1 - REMOVE ALL MOUNTING
HARDWARE
O ring
Gasket
Disk
Hexagonal nut
Shut off water supply and remove the hexagonal
nut, the disk and the gasket. Do not remove the
O-ring from the base of the tap.
STEP 2 -INSTALLING THE TAP
1. Place the tap with O-ring into the hole in deck or lavatory. Make sure the
O-ring is located between the deck or lavatory and the bottom of the tap.
2. Slide the gasket over the flexible hose.
3. Secure the tap to deck or lavatory with the hexagonal nut and the disk.
STEP 3 - CONNECTING THE WATER SUPPLY
1. a. For DB840 and, DB845: Connect the flexible pipe to the water supply.
b. For DB850 and DB875: Connect the red flexible pipe to the hot water supply
and the blue pipe to the cold water supply.
2. Make sure that the filter/s is/are installed between the flexible pipe and the shut
off valve (not supplied).
3. Turn on the central water supply and the shut-off valve/s.
4. Check for leaks.
STEP 4 - CONNECTING THE POWER SOURCE
This product includes a self adjusting sensor. The ideal sensor range for the specific
location will be set automatically.
Important: Check that no objects are in
Now remove the protecting
front of the sensor besides the washbasin.
sticker that covers the sensor.
6 | Dolphin Blue | DB840 / DB845 / DB850 / DB875
TAP INSTALLATION
If your model is DB840 or DB850:
Important: Check that no objects are in
Now remove the protecting
front of the sensor besides the washbasin.
sticker that covers the sensor.
Install the battery's box at the wall underneath the sink using the two sided adhesive
foam facet. The cable connection must point down. (You can use an optional
extension cable in order to assemble the battery box up to 10ft. away from the sink.)
4. If your model is DB845 or DB875: Plug the transformer into the electricity
socket and connect the connectors.
5. Wait about 5 seconds in order to allow the system to set the ideal sensor
range. After the self adjustment has taken place the solenoid valve will be opened
and closed for 1 second. As an indication, you will see a small amount of water
delivered from the spout. Then the product will be ready for use.
6. If the obtained range is unsatisfactory, refer to the section entitled "Range
adjustment".
Note: This tap includes a special aerator that allows you to
adjust the water stream direction on site in order to prevent water
splashing if needed. To change the angle of the water stream, simply
move the adjustable tilting plate by pressing it smoothly.
DB840 / DB845 / DB850 / DB875 | Dolphin Blue | 7
SETTING ADJUSTMENT
Detection
Delay out time
Delay in time
Temporary off function
Entrance to the self
adjustment mode
Reset
Lock out time
Adjusting the sensor with the remote control
If necessary, the sensor settings can be adjusted as following:
Shut off the water supply. In order to adjust the sensor with the remote control,
hold the remote control straight in front of the sensor in a distance of about
6-8" (15-20cm). Choose the function you want to adjust by pressing once on
one of the function buttons. After pressing once on a specific function button, a
quick flashing of the red light at the front of the sensor will occur. At this stage,
you can change the setting by pressing the (+) or the (-) buttons, every push will
increase or decrease one level. After finishing the adjustment, turn the water
supply back on.
8 | Dolphin Blue | DB840 / DB845 / DB850 / DB875
RANGE ADJUSTMENT
DETECTION RANGE: DETECTION RANGE: This tap was supplied
with a Self Adjusting Sensor. The ideal detection range for the specific
location will be set automatically. Only if necessary, use the remote
control to adjust the sensor range as follows:
Press the RANGE button. Wait until a quick flashing of the red light of the sensor
eye is perceived. Then, press + to increase the one level and - to reduce it every
push will increase or decrease one level.
Note: Once you have changed the detection range with the remote control, this
distance will be remembered by the sensor, even if the power source is
disconnected. To get back to the self adjustment mode, use the ADJ button only.
ENTRANCE TO THE SELF ADJUSTMENT MODE: Check that no
objects are in front of the sensor. Press the ADJ button. Once a quick
flashing of the red light of the sensor eye is perceived, remove your
hand holding the remote control and move away from the sensor area. The ideal
sensor range for the specific location will be set automatically. Once the self
adjustment has taken place the solenoid valve will be opened and closed for 1
second as an indication that the ideal sensor range was set and the product is ready
for use.
SECURITY TIME: The Security time, prevents continuous running
of water due to reflections or vandalism. By default, if the sensor
is covered for more than 90 seconds the water flow will shut
automatically. To resume regular operation any obstruction must be removed.
Press the SEC button. Wait until a quick flashing of the red light of the sensor eye is
perceived. Then, press +to increase the security time and - to reduce it.
DB840 / DB845 / DB850 / DB875 | Dolphin Blue | 9
RANGE ADJUSTMENT
DELAY IN TIME: It is recommended to change the delay in time for
flush valves for urinals or toilets only.
If required, the delay intime can also be modified in taps as follows:
Press the IN button. Wait until a quick flashing of the red light of the sensor eye is
perceived. Then, press +to increase the delay in time and - to reduce it.
DELAY OUT TIME: This button allows modifying the water flow time
after the user removes his hands from the tap. A delay out time
close to 0 will save more water. An increased delay out time will make
the user experience more comfortable.
If required, the delay out time can be modified as follows: Press the OUT button.
Wait until a quick flashing of the red light of the sensor eye is perceived. Then, press
+to increase the delay out time and - to reduce it.
TEMPORARY OFF FUNCTION: This function is ideal to perform any
kind of activity in front of the sensor without operating the system (for
example, cleaning). The tap will remain shut for 1 minute when this
button is pressed once. To cancel this function and to return to normal operation
press the On/Off button again or wait 1 minute.
RESET BUTTON: This function restores al the factory settings except
for the sensor range. If required, press the Reset button and without
releasing it, press the +button once.
Note: To enter the self adjusting mode, use the ADJ button. To change the sensor I
range, use the RANGE button.
10 | Dolphin Blue | DB840 / DB845 / DB850 / DB875
BATTERY REPLACEMENT
When the battery weakens, the red indicator light will blink at a constant rate. The
battery must be replaced within two weeks.
TO REPLACE THE BATTERY IN DB840, DB850:
1
Carefully open the battery's box.
2
Remove the old battery.
3. Replace the used battery with a new 9 v battery. A lithium battery is
recommended.
4
Close the box.
DB840 / DB845 / DB850 / DB875 | Dolphin Blue | 11
BATTERY REPLACEMENT
Note : If you did not change the sensor detection range with the remote control,
the system will perform a new self adjustment after the reconnection of the battery.
Check that there
are no objects in
front of the
sensor after the battery
replacement was completed.
Important: Spent batteries should not
be disposed of with normal household
waste. Contact your local authority for
information on waste disposal and recycling.
After you have replaced the
battery, move away from the
sensor range. Wait 5
seconds in order to allow
the system to set the ideal
sensor range. Then after the
self adjustment has taken
place the solenoid valve will
be opened and closed for 1
second as an indication that
the ideal sensor range was
set and the product is ready
for use.
MAINTENANCE
Filter cleaning instructions
This tap is provided with one or two stainless steel filter/s preventing foreign
particles to enter the lines. If the water flow has decreased, this may be because
the filter is clogged. The filter can be cleaned as follows:
1
Shut-off the water shutoff valve.
2. Disconnect the flexible pipe.
3
Remove the filter/s and wash it/them under running water.
4
Reassemble the parts.
5
Reconnect the flexible pipe and restore the incoming water supply.
6
Make sure that there is no water leakage.
CARE AND CLEANING OF CHROME AND SPECIAL FINISHES
DO NOT use steel wool or cleansing agents containing alcohol, acid, abrasives, or
the like. Use of any prohibited cleaning or maintenance products or substances
could damage the surface of the tap. For surface cleaning of taps use ONLY
soap and water, then wipe dry with clean cloth or towel.When cleaning bathroom
tile, the taps should be protected from any splattering of harsh cleansers.
12 | Dolphin Blue | DB840 / DB845 / DB850 / DB875
TROUBLE SHOOTING
DB840 / DB845 / DB850 / DB875 | Dolphin Blue | 13
SPARE PARTS LISTING
DB840, DB845:
PART NAME
PART CODE
Interoperable Solenoid Valve
DB07500065
Seals and Screws Kit .
DB07210082
Cover Kit
DB07270106
Nano Sensor
DB08004006
9V Battery box
DB06520008
9V Transformer
DB06522042
IP67 Battery box
DB06530020
IP67 Box with Transformer
DB06530021
DB850, DB875:
PART NAME
PART CODE
Interoperable Solenoid Valve
DB07500065
Seals and Screws Kit
DB07210083
Cover Kit
DB07270106
Nano Sensor
DB08004006
Mixing Handle kit .
DB07260008
9V Battery box
DB06520008
9V Transformer
DB06522042
IP67 Battery box
DB06530020
IP67 Box with Transformer
DB06530021
14 | Dolphin Blue | DB840 / DB845 / DB850 / DB875
LIMITED WARRANTY
Dolphin Solutions Ltd warrants that its electronic taps, flush valves and
controls will be free of defects in material and workmanship during normal
use for two years from the date the product is purchased.
If a defect is found in normal use, Dolphin Solutions Ltd will, at its
discretion, repair, provide a replacement part or product, or make
appropriate adjustments. Damage caused by accident, misuse, or abuse is
not covered by this warranty. Improper care and cleaning will void the
warranty. Proof of purchase (original sales receipt) must be provided to
Dolphin Solutions Ltd with all warranty claims. Dolphin Solutions Ltd is not
responsible for labour charges, installation, or other incidental or
consequential costs other than those noted above. In no event shall the
liability of Dolphin Solutions Ltd exceed the purchase price of the tap,
valve or control.
If you believe that you have a warranty claim, contact your Dolphin
Distributor, Dealer or Plumbing Contractor. Please be sure to provide all
pertinent information regarding your claim, including a complete
description of the problem, the product, model number, the date the
product was purchased, from whom the product was purchased and the
installation date. Also include your original invoice.
DOLPHIN SOLUTIONS LTD AND/OR SELLER DISCLAIM ANY
LIABILITY FOR SPECIAL, INCIDENTAL OR CONSEQUENTIAL
DAMAGES. This warranty excludes product damage due to installation
error, incorrect maintenance, wear and tear, battery, water composition,
product abuse, or product misuse, whether performed by a contractor,
service company, or the consumer. This warranty does not cover product
damage caused by the following:
• Incorrect installation, inversions of supply pipes.
• Pressures or temperatures exceeding recommended limits.
• Improper manipulation, tampering, bad or lapsed maintenance.
• Foreign bodies, dirt or scale introduced by the water supply.
DB840 / DB845 / DB850 / DB875 | Dolphin Blue | 15
Tel: +44 (0)1424 20 22 24
Fax: +44 (0)1424 205 200
info@dolphinsolutions.co.uk
www.dolphinsolutions.co.uk
Southpoint, Compass Park, Bodiam, Robertsbridge, TN32 5BS
Dolphin Solutions Ltd
egnaR letoH elbamusnoC
s
tcudorP
seilimaF
smeti detaleR
noitallatsnI
ediuG
178 Dolphin Dispensers
page 180
DBL 400
Technical helpline
page 11
WP 106
ybaB
gnignahC
• Operating pressure
0.5–8.0 bar (7–116
PSI)
• Maximum water
temperature 70ºC
• 2 year manufacturer
’s warranty
• WRAS Approved
Product
sliaR barG
01424 202224
combat Legionella
– please specify at
time of orering
• Mandatory Hygiene
Flush feature can
be specified to
control (DB51 – see
page 188)
• Tap settings can
be adjusted manually
or by using remote
• Neopearl Aerator
please specify at
time of ordering)
• Flow rate – 6 litres/minute
(down to 1.89 litres/minute
page 183
–
premixed applications.
For 2 inlet hot and
cold feed see
TMV3 thermostatic
mixing valve is recommende
• Water Supply:
d for
Single inlet cold or
pre-mixed – a TMV2
plated brass finishes
or
available
• Quality polished
chrome plated brass
or lacquered nickel
contamination
• Touch Free Tap
– for ultimate hygiene
– prevents cross
DB 200 / DB 225
Dolphin Blue Infrared
Tap
page 12
WP 208R
page 105
WP 112R
01424 202224
page 159
BC 2006
• Powered by 9v
plug in transformer
• Powered by 6
DB 225S
x AAA / 9v PP3 battery
DB 200S
(designed to match
brushed stainless
steel)
Brushed nickel finish
• Powered by 9v
plug in transformer
• Powered by 6
x AAA / 9v PP3 battery
Polished chrome
finish
Product Codes
DB 225C
DB 200C
page 190-191
low battery warning)
– for other power
source options see
• Power: Plug-in
9 volt transformers
or 9 volt battery (with
• 3/8" BSP water
supply connector
• Counter hole Ø
28-34mm Min-max
thickness 2-27mm
• Power Connections:
tap male, power
source female
• Projection 105mm
• H 142 x Ø 45 mm
Product Data
paoS
sresnepsiD
source
Power
Ø50
Ø45
001
135°
Counter Mounte
d
241
eussiT telioT lew
oT repaP noitani
resnepsiD
bmoC dnaH riA t
resnepsiD
oH
stinU
sreyrD
spaT
sniB
moorhsaW
seirosseccA
page 178
DB 200
105
Taps
Bellchem WD9
174-269 taps,
bins, access.qxd
:Layout 1
DOLPHIN
Request your 200 page
catalogue today on
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising