User Guide

User Guide
 Built for the best performance |
Intelligent Moving Head
Professional Lighting Technology
User Guide
TABLE OF CONTENTS
. Safety Instruction
. Technical Specification
. Lamp
. How To Set The Unit
| 4.1 Control Panel
4.2 Main Function
. How To Control The Unit
| 5.1 Master/Slave Built-In Preprogrammed Function.
— 5.2 Easy Controller | a
5.3 Universal DMX Controller
5.4 DMX512 Configuration
5.5 DMX512 Connection
. Troubleshooting
. Fixture Cleaning
ENT
A
WARNING
Please read carefully the instruction, which inciudes important
information about the installation, usage and maintenance.
Please keep this User Guide for future consultation. If you sell the unit to another user, be
sure that they also receive this instruction booklet
Unpack and check carefully there is no transportation damage before using the unit.
Before operating, ensure that the voltage and frequency of power Supply match the power
requirements of the unit. |
The unit is designed for use with the ELC 24V 250W. Do not use any other type of lamp.
Its important to ground the yellow/green conductor to earth in order to avoid electric shock.
The unit is for indoor use only. Use only in a dry location.
The unit must be installed in a location with adequate ventilation, at least 50cm from
adjacent surfaces. Be sure that no ventilation slots are blocked.
Disconnect main power before fuse/lamp replacement or servicing.
Replace fuse/lamp only with the same type. |
Make sure there is no flammable materials close to the unit while operating as it is fire
hazard. | |
Use safety chain when fixes this unit. Don’t handle the unit by taking its head only, but
always by taking its base.
Maximum ambient temperature is TA: 40°C. Don t operate it at where the temperature is
higher than this.
Unit surface temperature may reach up to 85C. Don't touch the housing bare-hand during
its operation, and allow about 15 minutes to cool down before replacing bulb or serving, as
the unit could be very hot.
In the event of serious operating problem, stop using the unit immediately. Never try to
repair the unit by yourself. Repairs carried out by unskilled people can lead to damage or
malfunction. Please contact the nearest authorized technical assistance center. Always use
the same type spare parts. | |
Don't connect the device to any dimmer pack.
Do not touch any wire during operation as high voltage might be causing electric shock.
3 Warning
|
|
To prevent or reduce the risk of electrical shock or fire, do not expose the unit to rair
or moisture. a
Never touch bulb with bare fingers as it is very hot after using.
Hot lamp explosion hazard. Do not open the unit within five minutes after switching off.
Do not start on the unit without bulb enclosure or housing are damaged.
The housing, the lenses, or the ultraviolet filter must be replaced if they are visibly
damaged. |
Do not look directly at the light while the bulb is on.
Caution
There are no user serviceable parts inside the unit. Do not open the housing or
attempt any repairs yourself. In the unlikely event your unit may require service,
please contact your nearest dealer.
Installation
The unit should be mounted via its screw holes on the bottom of the base. Use clamps to fix th
| unit to truss. Always ensure that the unit is firmly fixed to avoid vibration and slipping while
operating. Always ensure that the structure to which you are attaching the unit is secure and is
| able to support a weight of 15kgs for each unit.
e Power supply
- AC 120V-60HZ
- AC 230/240/250V~50/60Hz
e Lamp
- ELC 24V 250W
e Optical system
—- Standard 11* focused beam angle.
- Focus can be adjusted by manual.
e Gobo wheel —
- Independent gobo wheel with 14 gobos plus open and shutter.
- Blackout, and strobe speed variable(1~7 flashes per second).
e Color wheel | a
—- Independent color wheel with 11 dichroic mirrors plus white.
e Movement |
- Pan : 540° in 2.8 second.
- - Tilt : 270° in 1.6 second.
«DMX Channels —
a 4
- Standard DMX512 signal addressing and can be controlied by any universal DMX controller.
Channel 1 = Shutter
Channel 2 = Gobos
Channel 3 = Colors
Channel 4 = Pan motion
Channel 5 = Tilt motion
e Dimension : 290mm x 330mm x 380mm (Lx W x H)
e Weight : 11 kgs
. ``
In case of replacement of the lamp or maintenance, do not open the
fixture within 15 minutes until the unit cools down after switching off.
e Lamp:
ELC 24V 250W
1 1.Always switch off the main supply and never handle the lamp or luminaries when is ho!
2.Do not touch the bulb with bare hands. If this happens, clean the lamp with denatured
alcohol and wipe it with a lint free cloth before installation.
' 3. Never operate the lamp without appropriate shielding.
4. Make sure the lamp is located in the center for the best spot.
Diagram for Lamp changing
4. How To Set The Unit
4.1 Control Panel
4
eu DO
3
O |
Cc
О
m
NTER
© рмх
O MASTER
O SLAVE
O © sounn
MIN MAX.
SENSITIVITY
MIC ONLY FOR REMOTE
CONTROL (CA-6)
WO
DMX IN
DMX OUT 7
1. Display
To show the various menu and the selected functions.
2. LED
DMX On DMX input present
MASTER On master mode
SLAVE On - slave mode
SOUND Flashing — [sound activation
3. Button |
MENU to select the programming functions
DOWN to go backward in the selected functions
UP to go forward in the selected functions
ENTER to confirm the selected functions
4. Remote controller input
By connect to the 1/4" microphone jack to control the unit for Stand by, Strobe/Next and
Fast/Slow function.
5. Sensitivity
To adjust the microphone-receiving sensitivity.
6. Microphone
To receives audio signal for sound activation.
7. DMX input/output
For DMX512 link, use 3-pin XLR plug cable
to link the unit together.
4.2 Main Function
To select any of the given functions, press the MENU button up to when the required one i
showing on the display. Select the function by ENTER button and the display will blink. Use
DOWN and UP button to change the mode. Once the required mode has been selected, press
. the ENTER button to setup or it will automatically return to the main functions without any
change after idling 8 seconds. To go back to the functions without any change press the MENL
button. The main functions are showing below:
5 DMX512 Address Setting
51e |
ena [Sh $ Show Mode "Show 1"
на — En Y Show Mode" Show 2"
no Slave Mode " Normal"
—=1 SH Slave mode " 2 Light Show 2 "
Pan Normal |
Pan inversion
MENU re pue | Tilt Normal
ВО . | .
i Tilt Inversion
es 1 dof Display Normal
“LO ea? ni
—d ar 1 Display Inversion
—FAgul Focus Adjust
Self-Test
hr Fixture Hours
ESPE) Reset
DMX512 Address Setting
Press the MENU button up to when the Adar is showing on the display. Pressing
ENTER button and the display will blink. Use DOWN and UP button to change the DMX512
address. Once the address has been selected, press the ENTER button to setup or
automatically return to the main functions without any change after 8 seconds. To go back to tt
functions without any change press the MENU button again.
Show Mode
Press the MENU button up To when the Shia is showing on the display. Pressing
ENTER button and the display will blink. Use DOWN and UP button to select the Sh i
(show 1) or Sh e (show 2) mode. Once the mode has been selected, press the ENTER
button to setup or automatically return to-the main functions without any change after 8 seconds. .
To go back to the functions without any change press the MENU button again.
ML: ;
Shi Show 1 mode- Fixture is placed on the floor. Tilt movement angle 210°.
She ix
Show 2 mode-Fixture is fixed under ceiling. Tilt movement angle 90°.
Slave Mode
TA
Press the MENU button up to when the JL
ENTER button and the display will blink. Use DOWN and UP button to select the no
(normal) or CL Sh (2 light show) mode. Once the mode has been selected, press the ENTER
button to setup or automatically return to the main functions without any change after 8 seconds.
is showing on the display. Pressing
To go back to the functions without any change press the MENU button again.
Pan Inversion
ui
Press the MENU button up to when the | Pan
fs
ENTER button and the display will blink. Use DOWN and UP button to select the 15
(normal) or - (pan inversion) mode. Once the mode has been selected, press the
ENTER button to setup or automatically return to the main functions without any change after 8
is showing on the display. Pressing
seconds. To go back to the functions without any change press the MENU button again.
1 IE
LL Tit Inversion
A |
4 L |
T
Press the MENU button up to when the is showing on the display. Pressing
ENTER button and the display will blink. Use DOWN and UP button to select the ne .
(normal) or (pan inversion) mode. Once the mode has been selected, press the
ENTER button to setup or automatically return to the main functions without any change after 8
seconds. To go back to the functions without any change press the MENU button again.
7
терр
}
Display Inversion
It is good Î for you to install the unit on the floor or under ceiling. Press the MENU button up
to when the is blinking on the display. Use the ENTER button to change to the mode
e: (display inversion), It will automatically store after 8 seconds. Or press the ENTER
button again return to the mode bash (display normal). To go back to the functions press th
MENU button.
i gor Display normal mode for the fixture putting on the floor.
— di
Display inversion mode for the fixture fixing under ceiling.
СО)!
MOL
Focus Adjust
Press the MENU button up to when the Hd is blinking on the display. Pressing
ENTER button, the unit will focus on tilt 90°, and then the unit will focus on pan 0°, pan 90°,
pan180°, pan270° in every pressing ENTER button. To go back to the functions press the
MENU button again.
LL:
Self-Test
Press the MENU button up to when the ELSE is blinking on the display. Pressing
ENTER button and the unit will run self-test by built in program. To go back to the functions
pres the MENU button again.
Fixture Hours
Press the MENU button up to when the the is blinking on the display. Pressing
ENTER button and the display will show the number of working hours of the unit. To go back t
the functions press the MENU button again.
Reset
Press the MENU button up to when the rote is blinking on the display. Pressing
ENTER button and all channels of the unit will return to their standard position. To go back to
the functions press the MENU button again. |
E 5. How To Control The Unit
You can operate the unit in three ways:
1. By master/slave built-in preprogram function
2. By easy controller |
3. By universal DMX controller
No need to turn the unit off when you change the DMX address, as new DMX address
setting will be effected at once. Every time you turn the unit on, it will show AE-5 on the display
and move all the motors to their ‘home’ position and you may hear some noises for about 20
seconds. After that the unit will be ready to receive DMX signal or run the built in programs.
5.1 Master/Slaver Built In Preprogrammed Function
By linking the units in master/slave connection, the first unit will control the other units to —
give an automatic, sound activated, synchronized light show. This function | is good when you !
want an instant show. You have to set the first unit in master mode ! Shi NI and select 4
(show 1) or 22) (show 2) mode. Its DMX input jack will have nothing plugged into it, ang
master LED will be constantly on and sound LED will flash to the music. The other units wi - |
have to set in slave mode Siig and select No (normal) or cLSh (2 light show)
mode, Their DMX cables plugged into the DMX input jacks (daisy chain) and the slave led Ш ghts
will constantly on.
2-light show
on SL (slave mode), ne means the unit works normally and cLSh means 2- light
show. In order to create a great light show, you can set ! ELSA on the second unit to get
contrast movement to each other, even if you have two units only.
all the other units for Stand by, Strobe/Next and Fast/Slow function.
2. STROBE/NEXT : Under FAST mode, the light will strobe in three
N 5.7 Easy Controller
| | - The easy remote control is used only in master/slave mode. By connecting to the 1/4”
“microphone jack of the first unit, you will find that the remote control on the first unit will control
1. STAND BY : To blackout ail the unit.
different ways:
a.) Strobe in different gobos and colors.
b.) Synchronous strobe in white color.
с.) Two-light strobe in white color.
If the unit in slow mode, press NEXT button to choose desired color
and gobo. it will change ten colors and then change one gobo.
3. FAST/SLOW : When the LED is off, it is in FAST mode. The unit's movement- Pan/Tilt &
Gobo/Color is sound activated. If the LED on, it is in SLOW mode, Pan/Tilt is sound activated
but Gobo/Color wheel are static, controlled by Next button.
5.3 Universal DMX Controller
| If you use a universal DMX controller to control the units, you have to set DMX address
from 1 to 512 channel so that the units can receive DMX signal.
Press the MENU button up to when the ddr is showing on the display. Pressing
ENTER button and the display will blink. Use DOWN and UP button to change the DMX512
address. Once the address has been selected, press and keep ENTER button pressed up to
when the display stops blinking or storing automatically 8 seconds later. To go back to the
functions without any change press the MENU button again. Please refer to the following
diagram
to address your DMX512 channel for the first 4 units.
5,5 DMX512 Connection
5.4. DMX512 Configuration
DMX512 CONFIGURATION ~The DMX512 is widely used in intelligent lighting control, with a maximum of 512 channels
CHANNEL 1 CHANNZL 2 CHANNEL 3 CHANNEL 4 CHANNEL 5 > 2
SHUTTER GOOD COLOR PAN TILT у
255 2557 East 255 т Fast TOT
5 <ÁZ <>
| . e e
4
ва с U
1964 60990 Shaking: |
5 74 | DMX512 COMMON 120 ohm 1/4W
® DMX +
A Sw Slow INPUT . 2)
02
‘ 7 DMX -
1354 Gobo/Calor () 0) Termination reduces signal errors and to avoid signal
128 + 128 4 transmission problems and interference. It is always
15% [4204 Gezc 14 [4244 Magenta advisable to connect a DMX terminal.
1174 Gezs13 Yellow (Resistance 120 ohm 1/4W) between pin2 (DMX-) and
dy dy |104] Ge>:12 MOT Que pin3 (DMX+) of the last fixture.
Gcozc 11 99 + Е
4 | 52: 10 Light green :
88| Gozo eS y i 1. If you using a controller with 5 pins DMX output, you need to use a 5 to 3 pin adapter-cable
ca Lb Color 80 + === В 77 1 Pink
dy de 4 (727 Sonn 7 56 UY Purple 2. At last unit, the DMX cable has to be terminated with a terminator. Solder a 120 ohm 1/4W
e Т ell 55 Red resistor between pin 2(DMX-) and pin 3(DMX+) into a 3-pin XLR-plug and plug it in the
dy de 48 1 23% д | sa} Amber DMX-output of the last unit. 1
м 1 Cez-3 234 Light blue 3. Connect the unit together in a “daisy chain’ by XLR plug from the output of the unit to the
24 33 g y
are? .
Gobo 267 cer: 1 22 - ange input of the next unit. The cable can not be branched or split to a Y cable. DMX512 1s a ve
16 16+ 2-77 reen | -
- Stopped а +. Sur | LUE | ice high-speed signal. Inadequate or damaged cables, soldered joints or corroded connectors
opped ско =
С - 0- о = can easily distort the signal and shut down the system.
50505 4.The DMX output and input connectors are pass-through to maintain the DMX circuit, when
power is disconnected to the unit.
5. Each lighting unit needs to have an address set to receive the data sent by the
controller. The address number is between 0-511 (usually 0 € 1 are equal to 1).
"6. The end of the DMX512 system should be terminated to reduce signal errors.
7.3 pin XLR connectors are more popular than 5 pin XLR.
3 pin XLR: Pin 1: GND, Pin 2: Negative signal (-), Pin 3: Positive signal (+)
5 pin XLR: Pin 1: GND, Pin 2: Negative signal (-), Pin 3: Positive signal (+)
A oe
O 7
a
O
..
11 1
—
Co
co
NL
AN
6. Troubleshooting | | | |
Following are a few common problems that may occur during operation. Here are
some suggestions for easy troubleshooting: o “6. M The pan belt is broken
A. The unit does not work, no light and the fan does not work | - a 1. Turn off the main power.
1. Check the connect power and main fuse. 2. Unscrew all the screws (A) and open the base-housing cover (B).
2.Measure the mains voltage on the main connector. 3. Unplug all the connect wires (C) that from the arm to PC board and ignitor.
3, Check the power on LED. . 4, Unscrew the screws (D) that fix the axis gear (E). =
B. Not responding to DMX controiler | С hange a new belt (F) by going through all connect wires that from the arm to base, and
1. DMX LED should be on. If not, check DMX connectors, cables to see if link properly. . ; ough the bridge for correct position.
—2.1fthe DMX LED is on and no response to the channel, check the address settings and DMX et up the gear axis to the bridge and screwed it. Note : do not press the belt.
polarity. | a ut the belt around the axis gear and motor gear.
3. If you have intermittent DMX signal problems, check the pins on connectors or on PCB of the Plug all the connect wires (C) that form the arm to PC board and ignitor.
unit or the previous one. Adjust the pan home position.
crew the base-housing cover (B).
4. Try to use another DMX controller.
5. Check if the DMX cables run near or run alongside to high voltage cables that may cause
ts
damage or interference to DMX interface circuit.
C. Some units don’t respond to the easy controller |
1. You may have a break in the DMX cabling. Check the LED for the response of the master/
slave mode signal. | ©
2. Wrong DMX address in the unit. Set the proper address.
D. No response to the sound
1. Check the unit that is not receiving DMX signal.
2 Check the unit that is not set to display mode
3. Check microphone to see if it is good by tapping the microphone
E. One of the channels is not working well
1. The stepper motor might be damaged or the cable connected to the PCB is broken.
2. The motor's drive IC on the PCB might be out of condition.
F. The lamp is cutting out intermittently
1. The lamp is not working well, Check the main voltage either too high or too low.
2. internal temperature may be too high. Check and if necessary replace the fan on the head.
ARTIC Cleaning
The cleaning of internal and external optical lenses and/or mirrors must be carried out J
periodically to optimize light output. Cleaning frequency depends on the environment in which
the fixture operates: damp, smoky or particularly dirty surrounding can cause greater |
accumulation of dirt on the unit's optics. a В o 3
* Clean with soft cioth using normal glass cleaning fluid. E
*. Always dry the parts carefuliy. |
e Clean the external optics at least every 20 days. Clean the internal optics at least every 30/60
days. |
EC Declaration of Conformity
We declare that our products (lighting equipments) comply with the following
specification and bears CE mark in accordance with the provision of the
Electromagnetic Compatibility (EMC) Directive 89/336/EEC.
EN55014-1: 1993, EN61000-3-2: 1995, EN61000-3-3:1995 1
EN55014-2: 1997 CATEGORY || |
EN61000-4-2: 1995, EN61000-4-3: 1995, EN61000-4-4:1995
EN61000-4-5: 1995, EN61000-4-6: 1995, EN61000-4-11: 1994
Harmonized Standard
EN60598-1: 1993 ВЕ
Safety of household and similar electrical appliances
Part 1 : General requirements
| Following the provisions of the Low Voltage Directive 73/23/EEC and 93/68/EEC.
EC Declaration of Conformity
We declare that our products (remote controller) comply with the following
specification and bears CE mark in accordance with the provision of the
Electromagnetic Compatibility (EMC) Directive 89/336/EEC.
EN55015: 1993
EN50082-1: 1997 | | |
EN61000-3-2: 1995 |
EN61000-3-3: 1995 |
ит
Счет
3
LY
a л
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement