User Guide
TABLE OF CONTENTS
1. Safety Instruction
2. Technical Specification
3. Lamp
4. How To Set The Unit
4.1 Control Panel
4.2 Main Function
4.3 Home Position Adjustment
5. How To Control The Unit
5.1 Master/Slave Built-In Preprogrammed Function
5.2
5.3
5.4
5.5
Easy Controller CA-8
iSolution Operation / DMX Controller
DMX 512 Configuration
DMX 512 Connection
6. Troubleshooting
7. Fixture Cleaning
User Guide
Please read these instructions carefully before use
WWW.BEGLEC.COM
WWW.BEGLEC.COM
iMOVE-575W
Page: 1/17
WWW.BEGLEC.COM
iMOVE-575W
Page: 2/17
1. Safety Instruction
Please read the instruction carefully which includes important
WARNING
information about the installation, usage and maintenance.
y Please keep this User Guide for future consultation. If you sell the unit to another user, be sure that they also receive this instruction
booklet.
y Unpack and check carefully there is no transportation damage before using the unit.
y Before operating, ensure that the voltage and frequency of power supply match the power requirements of the unit.
y The unit is designed for use with the MSD 575W, MSR 575/2, NSD 575W or NSD 575/2 lamps. Do not use any other type of lamp.
y It’s important to ground the yellow/green conductor to earth in order to avoid electric shock.
y The unit is for indoor use only. Use only in a dry location.
y The unit must be installed in a location with adequate ventilation, at least 50cm from adjacent surfaces. Be sure that no ventilation slots
are blocked.
- AC 100V/120V - 60Hz
y Disconnect main power before fuse/lamp replacement or servicing.
- AC 230/240/250V - 50/60Hz
y Replace fuse/lamp only with the same type.
y Lamp
y Make sure there are no flammable materials close to the unit while operating, as it is fire hazard.
- MSD 575W or NSD 575W
- MSR 575/2 or NSD 575/2
y Use safety chain when fixes this unit. Don’t handle the unit by taking its head only, but always by taking its base.
y Maximum ambient temperature is Ta : 40
2. Technical Specification
y Power supply
. Don’t operate it where the temperature is higher than this.
y Optical system
- High efficiency optical system
y Unit surface temperature may reach up to 85
. Don’t touch the housing bare-hand during its operation, and allow about 15 minutes to
- High quality optical lens and dichroic colors
- Auto focus
cool down before replacing bulb or serving, as the unit could be very hot.
- Beam angle: 11 ~28
y In the event of serious operating problem, stop using the unit immediately. Never try to repair the unit by yourself. Repairs carried out by
unskilled people can lead to damage or malfunction. Please contact the nearest authorized technical assistance center. Always use the
same type spare parts.
y Shutter/Dimmer
- Blackout, 0~100% smooth dimming and strobe speed variable (1~10 flashes per second)
y Color wheel
y Don’t connect the device to any dimmer pack.
- Independent color wheel with 9 dichroic colors plus white.
- Color wheel rotates with variable speed, giving rainbow effect.
y Do not touch any wire during operation as high voltage might be causing electric shock.
y CMY Mixing system
- Cyan: 0 ~ 100%, Magenta: 0 ~ 100%, Yellow: 0 ~ 100%
Warning
y Effect Wheel
y To prevent or reduce the risk of electrical shock or fire, do not expose the unit to rain or moisture.
- Frost filter and diagonal lens
y Never touch bulb with bare fingers, as it is very hot after using.
y Movement
y Hot lamp explosion hazard. Do not open the unit within five minutes after switching off.
- Pan: 540° in 2.8 second.
y Do not start on the unit without bulb enclosure or housing are damaged.
- Tilt: 270° in 1.6 second.
y The housing, the lenses, or the ultraviolet filter must be replaced if they are visibly damaged.
- Automatic pan/ tilt homing correction.
y Do not look directly at the light while the bulb is on.
y DMX Channels
- Standard DMX 512 signal addressing and can be controlled by any universal DMX controller.
Caution
There are no user serviceable parts inside the unit. Do not open the housing or attempt any repairs by yourself. In the unlikely event your
16 Channels:
Channel 1 = Pan
Channel 2 = Tilt
unit may require service, please contact your nearest dealer.
Channel 9 = Yellow
Channel 10 = CMY color Mix
Channel 3 = Pan/Tilt Speed Channel 11 = CMY Speed
Channel 4 = Dimmer
Installation
The unit should be mounted via its mounting system ( as shown below ) on the bottom of the base. Use clamps to fix the unit to truss.
Always ensure that the unit is firmly fixed to avoid vibration and slipping while operating. Always ensure that the structure to which you are
attaching the unit is secure and is able to support a weight of 50 kgs for each unit. Also always use a safety cable that can hold 10 times of
Channel 12 = Effect Wheel
Channel 5 = Shutter
Channel 13 = Zoom
Channel 6 = Color
Channel 14 = Pan 16 bit
Channel 7 = Cyan
Channel 15 = Tilt 16 bit
Channel 8 = Magenta
Channel 16 = Lamp On/Off/Reset
the weight of the unit when installing the fixture.
WWW.BEGLEC.COM
iMOVE-575W
Page: 3/17
WWW.BEGLEC.COM
iMOVE-575W
Page: 4/17
5. Make sure the lamp is located in the center of the reflector for the best spot. Adjust lamp position by screws A, B and C.
8 Channels:
Channel 1 = Pan
Channel 2 = Tilt
Channel 3 = Shutter
Channel 4 = Effect wheel
Channel 5 = Color
Channel 6 = CYM Color Mix /Macro
Channel 7 = Dimmer
Channel 8 = Zoom
y Dimension: 428 x 387x 491 mm
y Weight: 30.5 kgs
4. How To Set The Unit
4.1. Control Panel
Luminous intensity:
Display
To show the various menus and the selected functions.
LED
DMX
On
DMX input present
MASTER
On
Master mode
SLAVE
On
Slave mode
SOUND
Flashing
Sound activation
MENU
To select the programming functions
DOWN
To go backward in the selected functions
Button
3. Lamp
In case of replacement of the lamp or maintenance, do not open the
fixture within 15 minutes until the unit cools down after switching off.
UP
To go forward in the selected functions
ENTER
To confirm the selected functions
WARNING
Because of its high internal pressure, there might be a risk that the Discharge lamp would explode during operation. The lamp emits
Remote controller input
intense UV radiation which is harmful to the eyes and skin. The high luminance of the arc can cause severe damage to the retina if
By connecting to the 1/4” microphone jack to control the unit for Stand by, Function, and Mode function.
looks directly at the lamp.
Sensitivity
To adjust the sound receives sensitivity.
Discharge lamp:
Microphone
MSD 575W or NSD 575W
MSR 575/2 or NSD 575/2
To receive audio signal for sound activated.
DMX input/output
1. Always switch off the main supply and never handle the lamp or luminaire when it is hot.
2. Do not touch the bulb with bare hands. If this happens, clean the lamp with denatured alcohol and wipe it with a lint free cloth
For DMX 512 link, use 3-pin XLR plug cable to link the unit together.
before installation.
3. The lamp generates UV radiation. Never operate the lamp without appropriate shielding.
4. When burning, the lamp operates at high pressure and there is a slight risk of arc tube rupture. The risk increases with age, temperature
and improper handling of the lamp. Do not use the lamp any longer than its specified life.
WWW.BEGLEC.COM
iMOVE-575W
Page: 5/17
WWW.BEGLEC.COM
iMOVE-575W
Page: 6/17
4.2. Main Function
To select any of the pre-set functions, press the MENU button until the required one is shown on the display. Select the function by ENTER
Show Mode
button and the display will blink. Use DOWN and UP button to change the mode. Once the required mode has been selected, press the
Press the MENU button until the
ENTER button to setup or it will automatically return to the main functions without any change after idling 8 seconds. To go back to the
button to select the
functions without any change press the MENU button. The main functions are shown below:
selected, press the ENTER button to setup or automatically return to the main functions without any change after 8 seconds. To go back to
is showing on the display. Pressing ENTER button and the display will blink. Use DOWN and UP
(show 1) or
(show 2) or
(show 3) or
(show 4) mode. Once the mode has been
the functions without any change press the MENU button again.
Show 1 mode - Fixture is placed on the floor. Tilt movement angle 210°.
Show 2 mode - Fixture is fixed under ceiling. Tilt movement angle 90°.
Show 3 mode - Fixture is placed on the speaker, The spot is always projecting
to the audience’s direction; i.e in front of the stage. Pan movement angle ( left to right to left ): 160°. Tilt movement angle: 90°
( 60° above horizon; 30° below horizon.)
Show 4 mode - Fixture is fixed under ceiling. The spot is mainly projecting in
front of the stage. Pan movement angle (left to right to left ) :160°. Tilt movement angle: 90° ( vertically, front 75°; back 15° )
Slave Mode
Press the MENU button until the
is shown on the display. Pressing ENTER button and the display will blink. Use DOWN and UP
button to select the
(normal) or
(2 light show) mode. Once the mode has been selected, press the ENTER button to
setup or automatically return to the main functions without any change after 8 seconds. To go back to the functions without any change
press the MENU button again.
Blackout Mode
Press the MENU button until the
is shown on the display. Pressing ENTER button and the display will blink. Use DOWN and UP
(yes blackout) or
button to select the
(no blackout) mode. Once the mode has been selected, press the ENTER button
to setup or automatically return to the main functions without any change after 8 seconds. To go back to the functions without any change
press the MENU button again.
Pan Inversion
Press the MENU button until the
button to select the
(normal) or
is shown on the display. Pressing ENTER button and the display will blink. Use DOWN and UP
(pan inversion) mode. Once the mode has been selected, press the ENTER button to
setup or automatically return to the main functions without any change after 8 seconds. To go back to the functions without any change
press the MENU button again.
DMX 512 Address Setting
Press the MENU button until the
is shown on the display. Pressing ENTER button and the display will blink. Use DOWN and UP
button to change the DMX 512 address.
Once the address has been selected, press the ENTER button to setup or automatically return to the main functions without any change
after 8 seconds. To go back to the functions
Tilt Inversion
Press the MENU button until the
button to select the
(normal) or
is shown on the display. Pressing ENTER button and the display will blink. Use DOWN and UP
(tilt inversion) mode. Once the mode has been selected, press the ENTER button to
setup or automatically return to the main functions without any change after 8 seconds. To go back to the functions without any change
without any change press the MENU button again.
press the MENU button again.
Led Display
Channel Mode
Press the MENU button until the
button to select the
Press the MENU button until the
is shown on the display. Pressing ENTER button and the display will blink. Use DOWN and UP
(16 Channel ) or
(8 Channel) mode. Once the mode has been selected, press the ENTER button to
setup or automatically return to the main functions without any change after 8 seconds. To go back to the functions without any change
button to select the
(Led on) or
is showing on the display. Pressing ENTER button and the display will blink. Use DOWN and UP
(Led off) mode. Once the mode has been selected, press the ENTER button to setup or
automatically return to the main functions without any change after 8 seconds. To go back to the functions without any change press the
MENU button again.
press the MENU button again.
WWW.BEGLEC.COM
iMOVE-575W
Page: 7/17
WWW.BEGLEC.COM
iMOVE-575W
Page: 8/17
4.3 Home Position Adjustment
Display Inversion
Press MENU button for at least 5 seconds into offset mode to adjust the home position, the functions are shown below:
It is good for you to install the unit on the floor or under ceiling. Press the MENU button until the
again return to the mode
is blinking on the display. Use the
(display inversion), It will automatically store after 8 seconds. Or press the ENTER button
ENTER button to change to the mode
(display normal). To go back to the functions press the MENU button.
Display normal mode for the fixture putting on the floor.
Display inversion mode for the fixture fixing under ceiling.
Focus Adjust
Press the MENU button until the
is blinking on the display. Pressing ENTER button and the display will blink. Use DOWN and UP
Pan offset
button to select the (0~255) value. Once the value has been selected, press the ENTER button to setup or automatically return to the main
Press the MENU button for at least 5 seconds into offset mode, use DOWN and UP button until the
functions without any change after 8 seconds. TO go back to the functions without any change press the MENU button again.
Pressing ENTER button and the display will blink. Use DOWN and UP button to adjust the pan home position. Once the position has been
is shown on the display.
selected, press the ENTER button to setup or automatically return to the offset functions without any change press the MENU button again,
Self-Test
to go back to the main functions without any change after 8 seconds.
Press the MENU button until the
is blinking on the display. Pressing ENTER button and the unit will run self-test by built-in
program. To go back to the functions press the MENU button again.
Tilt offset
Ambient temperature of lamp
Press the MENU button until the
Press the MENU button for at least 5 seconds into offset mode, use DOWN and UP button until the
is blinking on the display. Pressing ENTER button and the ambient temperature of lamp will
is shown on the display.
Pressing ENTER button and the display will blink. Use DOWN and UP button to adjust the tilt home position. Once the position has been
selected, press the ENTER button to setup or automatically return to the offset functions without any change press the MENU button again,
show on the display. To go back to the functions press the MENU button again.
to go back to the main functions without any change after 8 seconds.
Fixture Hours
Press the MENU button until the
is blinking on the display. Pressing ENTER button and the display will show the number of
working hours of the unit. To go back to the functions press the MENU button again.
Color offset
Press the MENU button for at least 5 seconds into offset mode, use DOWN and UP button until the
is shown on the display.
Pressing ENTER button and the display will blink. Use DOWN and UP button to adjust the color home position. Once the color has been
selected, press the ENTER button to setup or automatically return to the offset functions without any change press the MENU button again,
to go back to the main functions without any change after 8 seconds.
Lamp ON/OFF
is blinking on the display. Pressing ENTER button and the display will blink. Use DOWN and UP
Press the MENU button until the
button to select the
(Lamp on) or
(Lamp off) mode. Once the mode has been selected, press the ENTER button to setup
or automatically return to the main functions without any change after 8 seconds. To go back to the functions without any change press the
MENU button again.
is shown on the display.
Pressing ENTER button and the display will blink. Use DOWN and UP button to adjust the dimmer home position(0~255). Once the mode
has been selected, press the ENTER button to setup or automatically return to the offset functions without any change press the MENU
Lamp Mode
Press the MENU button until the
UP button to select the
Dimmer offset
Press the MENU button for at least 5 seconds into offset mode, use DOWN and UP button until the
is showing on the display. Pressing ENTER button and the display will blink. Use DOWN and
( Lamp mode on ) or
( Lamp mode off ) mode. Once the mode has been selected, press the
ENTER button to setup or automatically return to the main functions without any change after 8 seconds. To go back to the functions
without any change press the MENU button again.
button again, to go back to the main functions without any change after 8 seconds.
5. How To Control The Unit
You can operate the unit in three ways:
1. By master/slave built-in preprogram function
2. By easy controller CA-8
Reset
Press the MENU button until the
3. By IL-0824 ( please refer to the user guide of iLead controller ) or by universal DMX controller
is blinking on the display. Pressing ENTER button and all channels of the unit will return to their
No need to turn the unit off when you change the DMX address, as new DMX address setting will be effected at once. Every time you turn
the unit on, it will show 575U on the display and move all the motors to their ‘homing’ position. You may hear some noises for about 20
standard position. To go back to the functions press the MENU button again.
seconds. After the progress will be ready to receive DMX signal or run the built-in programs.
DMX RESET :
Set DMX value of channel 16 to 200~209, then all channels of the unit will return to their standard home position after about 5 seconds.
WWW.BEGLEC.COM
iMOVE-575W
Page: 9/17
WWW.BEGLEC.COM
iMOVE-575W
Page: 10/17
5.1. Master/Slave Built-In Preprogrammed Function
You can select blackout mode
in
(yes blackout) or
(no blackout) mode while the unit is turned on. By linking
the units in master/slave connection, the first unit will control the other units to give an automatic, sound activated, synchronized light show.
8 Channels
5.4. DMX 512 Configuration : 16-channel Mode DMX configuration
This function is good when you want an instant show. You have to select show (show 1, 2, 3, 4) modes by easy controller . Its DMX input
jack will have nothing plugged into it, and Its master LED will be constantly on and sound LED will flash to the music. The other units will
have to set in slave mode
and select
(normal) or
input jacks (daisy chain) and the slave LED lights will constantly on.
(2 light show) mode, Their DMX cables plugged into the DMX
2-light show
In
(slave mode),
you can set
means the unit works normally and
means 2-light show. In order to create a great light show,
on the second unit to get contrast movement to each other, even if you have two units only.
5.2. Easy Controller CA-8
The easy remote control is used only in master/slave mode. By connecting to the 1/4” microphone jack of the first
unit, you will find that the remote control on the first unit will control all the other units for Stand by, Function and
Mode.
Stand by
Function
Blackout the unit
Strobe
1. Color sync. strobe
2. Sync. strobe
3. Two-light strobe
Mode
Sound 1
(LED off )
X/Y moving show pattern selection
( Show 1 ~ Show 4 )
Please refer to 4.2. Main
Functions- Show mode
Color selection
Sound 2
(LED normal blinking)
Slow/Sound 3
(LED on)
X/Y moving setting
1.Pan position
2.Tilt position
3.Dimmer
First set Master unit, then set Slave units’
position
Position/ Latch
(LED fast blinking)
5.3.1 i Solution Operation
·Consistent DMX configuration enable iRock and iShow to be linked and controlled together at the same time.
·DMX address can be set remotely by iLead controller ( please refer to the user manual of iLead controller ). No need to calculate the DMX
channels of each fixture in the chain.
i.) The value as below will be effected after about five seconds,
·Automatic switching between DMX function and built-in stand alone programs.
For DMX reset, put DMX value of CH-16 to 200-209
For DMX lamp on, put DMX value of CH-16 to 130-139.
5.3.2 DMX Controller
If you use a universal DMX controller to control the units, you have to set DMX address from 1 to 512 channel so that the units can receive
For DMX lamp off, put DMX value of CH-16 to 230-239.
DMX signal.
Press the MENU button until the
is shown on the display. Pressing ENTER button and the display will blink. Use DOWN and UP
button to change the DMX 512 address. Once the address has been selected, press and keep ENTER button pressed until the display
stops blinking or storing automatically 8 seconds later. To go back to the functions without any change press the MENU button again.
Please refer to the following diagram to address your DMX 512 channel for the first 4 units.
16 Channels:
8 Channels
You have to set the fixture’ show mode in 8 channels mode when you use IL-0824 controller. DMX start address can be set remotely by
IL-0824 controller. No need to calculate the DMX channels of each fixture in the chain.
Please refer to the following diagram to address your DMX 512 channel for the first 4 units.
WWW.BEGLEC.COM
iMOVE-575W
Page: 11/17
WWW.BEGLEC.COM
iMOVE-575W
Page: 12/17
8-channel Mode DMX configuration
6. Troubleshooting
Following are a few common problems that may occur during operation. Here are some suggestions for easy troubleshooting:
A. The unit does not work, no light and the fan does not work
1. Check the connect power and main fuse.
2. Measure the mains voltage on the main connector.
3. Check the power on LED.
B. Not responding to DMX controller
1. DMX LED should be on. If not, check DMX connectors, cables to see if link properly.
2. If the DMX LED is on and no response to the channel, check the address settings and DMX polarity.
3. If you have intermittent DMX signal problems, check the pins on connectors or on PCB of the unit or the previous one.
4. Try to use another DMX controller.
5. Check in the DMX cables run near or run alongside to high voltage cables that may cause damage or interference to DMX interface
circuit.
C. Some units don’t respond to the easy controller
1. You may have a break in the DMX cabling. Check the LED for the response of the master/ slave mode signal.
2. Wrong DMX address in the unit. Set the proper address.
D. No response to the sound
5.5. DMX 512 Connection
1. Make sure that the unit is not receiving DMX signal.
The DMX 512 is widely used in intelligent lighting control, with a maximum of 512 channels.
2. Check microphone to see if it is good by tapping the microphone
E. One of the channels is not working well
1. The stepper motor might be damaged or the cable connected to the PCB is broken.
2. The motor’s drive IC on the PCB might be out of condition.
F. The lamp is cutting out intermittently
1. The lamp is not working well. Check the main voltage either too high or too low.
2. Internal temperature may be too high. Check and if necessary replace the fan on the head.
G. Pan Belt is broken
1. Turn off the main power.
2. Unscrew all the screws (A) and open the base-housing cover (B).
3. Unscrew all the screws (C) and open the arm cover (D).
4. Unplug all the connect wires that from the arm to the bottom.
5. Unscrew the screws (E) and remove the fixture head.
6. Loose the screws (F), then loose the screws (G).
1. If you use a controller with 5 pins DMX connector, you need to use a 5 to 3 pin adapter.
2. At last unit, the DMX cable has to be terminated with a terminator. Solder a 120-ohm 1/4W resistor between pin 2(DMX-) and pin
7. Change a new belt (H) , put the belt around the axis gear and motor gear.
8. Screwed the screws (G), install the new belt and adjust the belt tension properly. Note: do not fix belt too tight as it is easy to rupture.
3(DMX+) into a 3-pin XLR-plug and plug it in the DMX-output of the last unit.
3. Connect the unit together in a “daisy chain” by XLR plug from the output of the unit to the input of the next unit. The cable cannot be
branched or split to a “Y” cable. DMX512 is a very high-speed signal. Inadequate or damaged cables, soldered joints or corroded
9. Plug all the connect wires back that from the bottom to the arm.
10. Reverse the procedures from point 5 to point 2.
connectors can easily distort the signal and shut down the system.
4. The DMX output and input connectors are pass-through to maintain the DMX circuit, when power is disconnected to the unit.
5. Each lighting unit needs to have an address set to receive the data sent by the controller. The address number is between 0-511
(usually 0 & 1 are equal to 1).
6. The end of the DMX512 system should be terminated to reduce signal errors.
7. 3 pin XLR connectors are more popular than 5 pins XLR.
3 pin XLR: Pin 1: GND, Pin 2: Negative signal (-), Pin 3: Positive signal (+)
5 pin XLR: Pin 1: GND, Pin 2: Negative signal (-), Pin 3: Positive signal (+)
WWW.BEGLEC.COM
iMOVE-575W
Page: 13/17
WWW.BEGLEC.COM
iMOVE-575W
Page: 14/17
7. Fixture Cleaning
The cleaning of internal and external optical lenses and/or mirrors must be carried out periodically to optimize light output. Cleaning
frequency depends on the environment in which the fixture operates: damp, smoky or particularly dirty surrounding can cause greater
accumulation of dirt on the unit’s optics.
y Clean with soft cloth using normal glass cleaning fluid.
y Always dry the parts carefully.
y Clean the external optics at least every 20 days. Clean the internal optics at least every 30/60 days.
Pay attention to the belt tension when install the belt.
Please refer to the photos below:
EC Declaration of Conformity
We declare that our products (lighting equipments) comply with the following
specification and bears CE mark in accordance with the provision of the
Electromagnetic Compatibility (EMC) Directive 89/336/EEC.
EN55014-2: 1997 A1:2001, EN61000-4-2: 1995; EN61000-4-3:2002;
EN61000-4-4: 1995; EN61000-4-5: 1995, EN61000-4-6:1996,
EN61000-4-11: 1994.
&
Harmonized Standard
Photo 1
EN 60598-1: 2004
IEC 60598-1:2003+ corrigendum 2004
Part 1:General requirements and test
Following the provisions of the low voltage directive 73/23/EEC and 93/68/EEC
Photo 2
WWW.BEGLEC.COM
iMOVE-575W
Page: 15/17
WWW.BEGLEC.COM
iMOVE-575W
Page: 16/17
Innovation , Quality , Performance
WWW.BEGLEC.COM
iMOVE-575W
Page: 17/17
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project