Quanser IP01, IP02 Linear Motion Servo Plant User Manual
Below you will find brief information for Linear Motion Servo Plant IP01, Linear Motion Servo Plant IP02. The Quanser IP01 and IP02 are fundamental modules for the linear motion experiments. They consist of a precisely machined solid aluminum cart driven by a high quality DC motor equipped with a planetary gearbox. The cart slides along a stainless steel shaft using linear bearings. The cart is driven via a rack and pinion mechanism as opposed to belts or wheels, in order to eliminate slippage, belt stretching and other undesirable effects. This, therefore, ensures consistent and continuous traction.
Advertisement
Advertisement
Linear Motion Servo Plants: IP01 or IP02
IP01 and IP02
User Manual
IP01 and IP02 User Manual
Table of Contents
1. IP01 and IP02 Presentation..................................................................................................1
1.1. General Description.....................................................................................................1
1.2. IP01 (Inverted Pendulum) Particularities.....................................................................1
1.3. IP02 (Self-Erecting Inverted Pendulum) Particularities..............................................1
2. Module Options: List of Experiments Based on the IP02 Servo Plant...............................3
2.1. Linear Family Package.................................................................................................3
2.2. Module Options for either IP01 or IP02......................................................................4
2.3. Module Options Specific to the IP02...........................................................................4
2.4. Two-Cart (i.e. MIMO) Systems with either IP01 or IP02...........................................5
3. IP01 and IP02 Component Description...............................................................................6
3.1. Component Nomenclature...........................................................................................6
3.2. Component Description...............................................................................................8
3.2.1. Rack (Component # 3).........................................................................................8
3.2.2. DC Motor (Component # 13)...............................................................................8
3.2.2.1. Description...................................................................................................8
3.2.2.2. Wiring...........................................................................................................9
3.2.3. Planetary Gearbox (Component # 14)..................................................................9
3.2.4. IP01 Potentiometers (Components # 18 and 19)..................................................9
3.2.4.1. Description...................................................................................................9
3.2.4.2. Wiring.........................................................................................................10
3.2.5. IP02 Encoders (Components # 8 and 9).............................................................11
3.2.5.1. Description.................................................................................................11
3.2.5.2. Wiring.........................................................................................................11
4. IP01 and IP02 Model Parameters......................................................................................12
5. Wiring Procedure For The IP01 And IP02........................................................................14
5.1. Cable Nomenclature...................................................................................................14
5.2. Typical Connections for the IP01/IP02......................................................................16
5.2.1. Connections Common to both IP01 and IP02....................................................16
5.2.2. Connections Specific to the IP01.......................................................................17
5.2.3. Connections Specific to the IP02.......................................................................17
5.3. Typical Connections for the IP01/IP02 when using the Quanser Q3 ControlPAQ-FW
...........................................................................................................................................19
5.3.1. Connections Common to both IP01 And IP02...................................................20
5.3.2. Connections Specific to the IP01.......................................................................20
5.3.3. Connections Specific to the IP02.......................................................................20
6. Testing and Troubleshooting.............................................................................................21
6.1. The IP01 or IP02 DC Motor......................................................................................21
6.1.1. Testing................................................................................................................21
6.1.2. Troubleshooting.................................................................................................22
Document Number: 501 Revision: 5.0 Page: i
IP01 and IP02 User Manual
6.2. The IP01 Potentiometers............................................................................................22
6.2.1. Testing................................................................................................................22
6.2.2. Troubleshooting.................................................................................................23
6.3. The IP02 Encoders.....................................................................................................23
6.3.1. Testing................................................................................................................23
6.3.2. Troubleshooting.................................................................................................24
7. Obtaining Support..............................................................................................................24
Appendix A. DC Motor Specification Sheet.........................................................................25
Appendix B. Planetary Gearhead Specification Sheet..........................................................26
Appendix C. IP01 Cart Potentiometer Specification Sheet...................................................27
Appendix D. IP01 Pendulum Potentiometer Specification Sheet.........................................28
Appendix E. IP02 Encoder Specification Sheet....................................................................29
Document Number: 501 Revision: 5.0 Page: ii
IP01 and IP02 User Manual
1. IP01 and IP02 Presentation
1.1. General Description
The IP01 and IP02 are fundamental modules for the linear motion experiments.
They consist of a precisely machined solid aluminum cart driven by a high quality DC motor equipped with a planetary gearbox. The cart slides along a stainless steel shaft using linear bearings. The cart is driven via a rack and pinion mechanism as opposed to belts or wheels, in order to eliminate slippage, belt stretching and other undesirable effects. This, therefore, ensures consistent and continuous traction.
The following sections provide more insight into the differences between the IP01 and IP02 and their applications.
1.2. IP01 (Inverted Pendulum) Particularities
A typical IP01 is depicted in Figure 1, below. In the case of the IP01, the cart position is
sensed via a ten-turn potentiometer. The IP01 cart is also equipped with a rotary joint with ball bearings to which a free turning erected rod can be attached. This rod functions as an
"inverted pendulum" in subsequent experiments. The angle of the rod is sensed using a conductive plastic potentiometer.
However, the IP01 pendulum cannot suspend in front of the cart. Should you wish to deploy the pendulum to conduct a full 360-degree rotation the IP02 should be utilized instead.
1.3. IP02 (Self-Erecting Inverted Pendulum) Particularities
A typical IP02 is depicted in Figure 2, below. The IP02 pendulum can suspend in front of
the cart to perform self-erecting and gantry experiments. Consistently, the IP02 system has encoders, as opposed to potentiometers as in the IP01, to allow for multiple turns.
The IP02 cart position is sensed via an quadrature incremental encoder whose shaft meshes with the track via an additional pinion. The IP02 is also equipped with a rotary joint to which a free-swinging rod can be attached and suspends in front of the cart. This rod functions, in subsequent experiments, as an "inverted pendulum", but more precisely as a self-erecting inverted pendulum as well as a regular inverted pendulum. The angle of the rod inclination about the vertical axis is also measured using a quadrature incremental encoder and is therefore unlimited and continuous over the entire range of motion. The pendulum in itself is a module and can be mounted on or remove from the cart.
Document Number: 501 Revision: 5.0 Page: 1
IP01 and IP02 User Manual
Furthermore, in order to run the self-erecting experiment, the supplied extra mass needs to be attached to the cart, so that the swinging inertia of the pendulum does not lift the cart off the track.
Figure 1 IP01 System
Figure 2 IP02 System
Document Number: 501 Revision: 5.0 Page: 2
IP01 and IP02 User Manual
2. M
odule Options: List of Experiments
Based on the IP02 Servo Plant
Quanser values itself for the modularity of its experiments. This modular philosophy facilitates the change from one experimental setup to another with relative ease of work.
2.1. Linear Family Package
The IP02 linear plant module serves as the base component for the linear family of experiments, also known as the Linear Family Package. The "Linear Family" is a package that has all the modules required to configure 7 completely different challenges based on the IP02
(thus maximizing the return on your investment).
Table 1, below, provides a list of the modules members of the Linear Family Package. Each
one of them (individually or in combination) expands the range of possible experiments based on the IP02 linear motion servo plant.
Module Name
N/A
N/A
Experiment Description
Design of a control system to manipulate the position of the
IP01 or IP02 cart.
Design of two different control systems to manipulate the speed of the IP01 or IP02 cart.
Single Inverted Pendulum
(SIP)
Single Pendulum Gantry
(SPG)
Self-Erecting Single
Inverted Pendulum
(SESIP)
Single Linear Flexible Joint
(SLFJ)
Seesaw
Design of a control system that keeps the classical inverted pendulum balanced and tracks the cart to a commanded position.
Design of a control system to track a desired cart linear position while minimizing the swing of the suspended pendulum.
Design of a control system to swing up the pendulum, keep it upright and maintain the cart position.
Design of a control system to manipulate the position of a spring driven cart.
Design of a control system to balance a seesaw using a sliding powered mass.
Document Number: 501 Revision: 5.0 Page: 3
IP01 and IP02 User Manual
Module Name Experiment Description
Seesaw with SLFJ Design of a control system to balance a seesaw using a flexible structure mounted atop of it.
Table 1 Modules of the Linear Family Package
2.2. Module Options for either IP01 or IP02
Table 2, below, provides a list of all the modules compatible with the IP01 and IP02 linear
motion servo plants. These modules can be used individually or in combination. Some of them are part of the Linear Family Package.
Module Name
Single Inverted Pendulum
(SIP)
Experiment Description
Design of a control system that keeps the classical inverted pendulum balanced and tracks the cart to a commanded position.
Flexible Inverted
Pendulum
(FLEXPEN)
Linear Flexible Joint Cart
(LFJC)
Design of a control system to balance a flexible inverted pendulum.
Design of a control system to manipulate the position of a spring driven cart.
Single Linear Flexible Joint with Inverted Pendulum
(SLFJ with IP)
Design of a control system to balance a pendulum on a spring driven cart.
Seesaw
SLFJ on Seesaw
Design of a control system to balance a seesaw using a sliding powered mass.
Design of a control system to balance a seesaw using a flexible structure mounted atop of it.
Active Mass Damper – 1
Floor (AMD)
Design of a control system to dampen the vibrations in a building-like structure.
Table 2 IP01- and IP02-Based List of Modules
2.3. Module Options Specific to the IP02
Table 3, below, provides a list of the modules only compatible with the IP02 linear motion
servo plants. Some of them are part of the Linear Family Package.
Document Number: 501 Revision: 5.0 Page: 4
IP01 and IP02 User Manual
Module Name
Single Pendulum Gantry
(SPG)
Self-Erecting Single Inverted
Pendulum
(SESIP)
Double Inverted Pendulum
(DBIP)
Table 3 IP02-Based Modules
Experiment Description
Design of a control system to track a desired cart position while minimizing the swing of the linear suspended pendulum.
Design of a control system to swing up the pendulum, keep it upright and maintain the cart position.
Design of a control system to balance a double inverted pendulum on a linear motion cart.
2.4. Two-Cart (i.e. MIMO) Systems with either IP01 or IP02
Table 4, below, lists some of the possible combinations of the previous modules to
configure Multi-Input-Multi-Ouput (MIMO) experiments, based on either the IP01 or IP02.
Module Name Experiment Description
Seesaw / Inverted Pendulum Design of a control system to balance an inverted pendulum on top of a seesaw.
Active Mass Damper – 2
Floors (AMD-2)
Design of a control system to dampen the vibrations in a building-like structure using a MIMO approach.
Table 4 IP01- or IP02-Based MIMO Experiments
Document Number: 501 Revision: 5.0 Page: 5
IP01 and IP02 User Manual
3. IP01 and IP02 Component
Description
3.1. Component Nomenclature
As a quick nomenclature, Table 5, below, provides a list of all the principal elements
composing the IP01 and IP02 systems. Every element is located and identified, through a unique identification (ID) number, on the IP01 and/or IP02 systems represented in Figures
3, 4, 5, and 6, below, as well as Figures 7 and 8.
ID #
1
IP02 Cart
Description
3
Rack
5
Cart Motor Pinion
ID # Description
2
Stainless Steel Shaft
4
Cart Position Pinion
6
Cart Motor Pinion Shaft
7
Pendulum Axis
9
IP02 Pendulum Encoder
8
IP02 Cart Encoder
10
IP02 Cart Encoder Connector
11
IP02 Pendulum Encoder Connector
12
Motor Connector
13
DC Motor
14
Planetary Gearbox
15
Linear Bearing
17
IP02 Weight
19
IP01 Pendulum Potentiometer
21
S1 & S2 Connector
23
Rack Set Screw: (7/64)"
Table 5 IP01 and IP02 Component Nomenclature
16
Pendulum Socket
18
IP01 Cart Potentiometer
20
IP01 Cart
22
Rack End Plate
24
Track Discontinuity
Document Number: 501 Revision: 5.0 Page: 6
IP01 and IP02 User Manual
Figure 3 IP02: Front View
Figure 4 IP02: Bottom View
Figure 5 IP02 with Weight: Front View
Figure 6 IP01: Front View
Document Number: 501 Revision: 5.0 Page: 7
IP01 and IP02 User Manual
3.2. Component Description
3.2.1. Rack (Component # 3)
Table 6, below, lists and characterizes the overall dimensions of the rack used in the IP01
and IP02 systems:
Description Value Unit
Overall Rack Length
Overall Rack Height
Overall Rack Depth
Table 6 IP01 and IP02 Rack Overall Dimensions
1.02
6.10E-002
0.15
m m m
Moreover as illustrated in Figures 7 and 8 below, parts of the track are missing (feature or
"component" #24) at both ends of the IP01 or IP02 rack. This feature plays the role of a hardware safety watchdog in preventing the IP01 or IP02 cart from running into one of the track's ends, which could potentially be damaging.
Figure 7 Rack Left End
Figure 8 Rack Right End
3.2.2. DC Motor (Component # 13)
3.2.2.1. Description
The IP01 and IP02 incorporate a Faulhaber Coreless DC Motor (2338S006), as shown in
Figures 4 and 5 (component # 13), on page 7. This model is a high efficiency low induct-
ance motor resulting in a much faster response than a conventional DC motor. The complete specification sheet of the motor is included in Appendix A.
Document Number: 501 Revision: 5.0 Page: 8
IP01 and IP02 User Manual
CAUTION: High Frequency signals applied to a motor will eventually damage the
gearbox and/or the motor brushes. The most likely source for high frequency noise is derivative feedback. If the derivative gain is too high, a noisy voltage will be fed into the motor. To protect your motor, you should always band limit your signal (especially derivative feedback) to a value of 50Hz.
CAUTION: Input: ±15V, 3A peak, 1A continuous.
CAUTION: Exposed moving parts.
3.2.2.2. Wiring
The supplied motor cable is designed to connect from a Quanser Universal Power Module
to a 4-pin DIN connector, shown as component # 12 in Figures 3, 4, and 6, on page 7.
3.2.3. Planetary Gearbox (Component # 14)
In the IP01 and IP02, the DC motor is coupled to a Faulhaber Planetary Gearhead Series
23/1, as shown in Figures 4 and 5 (component # 14), on page 7. Its reduction ratio is
3.71:1. The complete specification sheet of the planetary gearbox is included in Appendix
B.
3.2.4. IP01 Potentiometers (Components # 18 and 19)
3.2.4.1. Description
The main difference between the IP01 and the IP02 is that the IP01 makes use of two potentiometers to sense both cart and pendulum positions, as opposed to the IP02 which uses two encoders instead.
As depicted in Figure 6 by component # 18, on page 7, the IP01 cart position is sensed by a
10-turn black potentiometer, namely the Vishay Spectrol model 534-1-1-103. As illus-
trated by its wiring diagram in Figure 9, the IP01 cart potentiometer is connected to a ±12
Volt DC power supply through two bias resistors of 7.15 kÙ each. According to the wiring
diagram Figure 9 and under normal operations, potentiometer terminal 1 should measure
+5VDC while terminal 3 should measure -5VDC. The actual position voltage is available at terminal 2. The total output range of the cart position potentiometer results to be ±5V over
Document Number: 501 Revision: 5.0 Page: 9
IP01 and IP02 User Manual its 10 complete turns (i.e. 3600 degrees). The main specifications of the IP01 cart poten-
tiometer are included in Appendix C, on page 27. Regarding the inverted pendulum poten-
tiometer, it is a Vishay Spectrol model 138-0-0-103. It is represented in Figure 6 by com-
ponent # 19. Its wiring diagram is also depicted in Figure 9. No bias resistor is used. On the
IP01, the inverted pendulum is mechanically constrained to the upright position and limited to a ±32º-deviation from the vertical, during which the pendulum potentiometer output is within approximately a 5-volt range. The main specifications of the IP01 pendulum poten-
tiometer are included in Appendix D, on page 28. Refer to Table 7, on page 13, for the res-
ulting potentiometer sensitivities.
3.2.4.2. Wiring
Both IP01 potentiometers are wired to one 6-pin mini DIN socket, as seen in the wiring
schematic in Figure 9. A picture of the same 6-pin mini DIN socket, represented as com-
ponent # 21, is also available in Figure 6. Once the 6-pin mini DIN socket is connected to a
power amplifier, e.g. Quanser VoltPAQ or Q3 ControlPAQ-FW, the potentiometer signals are typically available on S1 and S2, where S1 and S2 are, respectively, the voltages proportional to the IP01 cart position and pendulum angle.
Figure 9 IP01 Wiring of the Two Potentiometers
As a remark, it should be noted that a potentiometer measures an absolute position signal.
However, the zero position can be modified by manually adjusting the potentiometer "neutral" mounting position.
Document Number: 501 Revision: 5.0 Page: 10
IP01 and IP02 User Manual
3.2.5. IP02 Encoders (Components # 8 and 9)
3.2.5.1. Description
On the IP02, both cart and pendulum positions are measured with two optical encoders, rep-
resented in Figure 3 by components # 8 and 9, respectively. Having an encoder (as opposed
to a potentiometer) sensing the pendulum angular position no longer constrains the range of motion of the pendulum to the inverted position. Therefore, self-erecting inverted pendulum experiments become possible. The encoder measuring the IP02 cart linear position does so through a rack-pinion system. Both encoders are typically identical. The encoder model used in the IP02 is a US Digital S1 single-ended optical shaft encoder. It offers a high resolution of 4096 counts per revolution (i.e. 1024 lines per revolution with two channels in quadrature). The complete specification sheet of the S1 optical shaft encoder is included in
Appendix E. An incremental encoder gives a relative position signal.
3.2.5.2. Wiring
The position signal generated by the encoder should be directly connected to a Quanser terminal board (a.k.a. I/O card) using a standard 5-pin DIN cable. DO NOT connect the en-
coder signal to the amplifier. The internal wiring diagram of the IP02 encoder is depicted
in Figure 10. The standard 5-pin DIN connector, shown in Figure 10, is also pictured as
component # 10 or 11 in Figure 3.
Figure 10 IP02 Encoder Wiring
Document Number: 501 Revision: 5.0 Page: 11
IP01 and IP02 User Manual
4. IP01 and IP02 Model Parameters
Table 7, below, lists and characterizes the main parameters (e.g. mechanical and electrical
specifications, convertion factors) associated with the IP01 and IP02. Some of these parameters can be used for mathematical modelling of the IP01 and IP02 systems.
T c
P r r mp
N mp r pp
N pp
K
EC
J m
K g
η g
M c1
M c2
M w
L t
L m
K t
η m
K m
Symbol
V nom f max
I max
ω max
R m
Description
Motor Nominal Input Voltage
Motor Input Voltage Maximum Frequency
Maximum input current
Maximum motor speed.
Motor Armature Resistance
Motor Armature Inductance
Motor Torque Constant
Motor Efficiency
Back-ElectroMotive-Force (EMF) Constant
Rotor Moment of Inertia
Planetary Gearbox Gear Ratio
Planetary Gearbox Efficiency
IP01 Cart Mass
IP02 Cart Mass
IP02 Cart Weight Mass
Track Length
Cart Travel
Rack Pitch
Motor Pinion Radius
Motor Pinion Number of Teeth
Position Pinion Radius
Position Pinion Number of Teeth
IP02 Cart Encoder Resolution
Value
6.0
50
1.0
Unit
V
Hz
A rad/s
628.3
2.6
0.18
0.00767
Ω mH
N.m/A
%
100
0.00767
3.90E-007
3.71
V.s/rad kg.m
2
100
0.52
0.57
0.37
0.990
% kg kg kg m
0.814
m
1.664E-003 m/tooth
6.35E-003
24 m
0.01482975
56 m
2.275E-005 m/count
Document Number: 501 Revision: 5.0 Page: 12
IP01 and IP02 User Manual
Symbol Description
K
EP
α range
IP02 Pendulum Encoder Resolution
IP01 Inverted Pendulum Mechanical Range
K
PC
IP01 Cart Potentiometer Sensitivity
K
PP
IP01 Pendulum Potentiometer Sensitivity
Table 7 IP01 and IP02 System Paremeters
Value
0.0015
±32
º
0.000
-0.2482
Unit
rad/count
º m/V rad/V
Document Number: 501 Revision: 5.0 Page: 13
IP01 and IP02 User Manual
5. Wiring Procedure For The IP01 And
IP02
This section describes the standard wiring procedure for both IP01 and IP02.
The following hardware, accompanying the IP01 or IP02, is assumed:
●
●
Data Acquisition Board: Quanser Q2-USB, Q8-USB, QPID, Q3
ControlPAQ-FW, or equivalent.
Power Amplifier: Quanser VoltPAQ, Q3 ControlPAQ- FW, or equivalent.
5.1. Cable Nomenclature
Table 8, below, provides a description of the standard cables used in the wiring of the IP01
and IP02.
Cable Designation
2xRCA to
2xRCA
Description
This cable connects an analog output of the data acquisition terminal board to the power module for proper power amplification.
Figure 11 "Amplifier Command" Cable
4-pin-DIN to
6-pin-DIN
This cable connects the output of the power module, after amplification, to the desired actuator (i.e. IP01 or IP02 motor).
Figure 12 "To Load" Cable
Document Number: 501 Revision: 5.0 Page: 14
IP01 and IP02 User Manual
Cable
Figure 13 "Encoder" Cable
Figure 14 "From Analog Sensors" Cable
Designation
5-pin-stereo-DIN to
5-pin-stereo-DIN
6-pin-mini-DIN to
6-pin-mini-DIN
5-pin-DIN to
4xRCA
Description
This cable is specific to the
IP02 system. It carries the encoder signals between an encoder connector and the data acquisition board (to the encoder counter). Namely, these signals are: +5VDC power supply, ground, channel A, and channel B.
This cable is specific to the
IP01 system. It carries analog signals between one or two plant sensors and the amplifier, where the signals can be either monitored and/or used by an analog controller. For example, connected to the IP01, the cable provides a ±12VDC bias to the two potentiometers and carries the two wiper voltages to S1 and S2 on the amplifier.
This cable is needed by the
IP01 system. It carries the analog signals, previously taken from the plant sensors, unchanged, from the amplifier to the Digital-To-Analog input channels on the data acquisition terminal board.
Figure 15 "To Analog-To-Digital" Cable
Table 8 Cable Nomenclature
Document Number: 501 Revision: 5.0 Page: 15
IP01 and IP02 User Manual
5.2. Typical Connections for the IP01/IP02
Figure 16, below, shows necessary connections from the data acquisition terminal board
and the power amplifier to interface to an IP01 or IP02. The procedure is discussed below
Figure 16: Connections between IP02, DAQ, and power amplifier
5.2.1. Connections Common to both IP01 and IP02
As both IP01 and IP02 share the same DC motor, the "power" connections for both IP01 and IP02 are identical. These connections are described below:
1. Connect the "Amplifier Command" Cable
The "Amplifier Command" cable is the 2xRCA-to-2xRCA cable described in Table
Document Number: 501 Revision: 5.0 Page: 16
IP01 and IP02 User Manual
and shown in Figure 11. Connect the one of RCA ends of this cable to the Analog
Output 0 (i.e. DAC # 0) of the terminal board and the other RCA end (of the same colour) to the socket labelled "Amplifier Command" on the power amplifier. This
connection is illustrated by cable # 1 in Figure 16.
2. Connect the "To Load" Cable
The "To Load" cable is the 4-pin-DIN-to-6-pin-DIN cable described in Table 8 and
shown in Figure 12. First, connect the cable 4-pin-DIN connector to the IP01 or
amplifier socket labelled "To Load". The connection to the power amplifier is
illustrated by cable # 2 in Figure Figure 16, above.
5.2.2. Connections Specific to the IP01
In the case of the IP01, the two potentiometers have to be connected. To do so, follow the two steps described below:
3. Connect the "To Analog-To-Digital" Cable
The "To Analog-To-Digital" cable is the 5-pin-DIN-to-4xRCA cable described in
Table 8 and shown in Figure 15. First, connect the cable 5-pin-DIN connector to the
labelled with a single digit ranging from one to four. This numbering corresponds to the four possible analog sensor signals passing through the amplifier, namely S1,
S2, S3 and S4. In order for the analog signals to be used in software, you should then connect all four RCA connectors to the first four analog input channels of your
DAQ Terminal Board. Specifically, connect S1 to Analog Input 0, S2 to Analog
Input 1, S3 to Analog Input 2, and S4 to Analog Input 3, as illustrated by cable #3
4. Connect the "From Analog Sensors" Cable
The "From Analog Sensors" cable is the 6-pin-mini-DIN-to-6-pin-mini-DIN cable
described in Table 8 and shown in Figure 14. First connect one end of the cable to
the IP01 S1 & S2 Connector, which is shown as component # 21 in Figure 6. Then
connect its other end to the amplifier socket labelled "S1 & S2", which is contained inside the amplifier "From Analog Sensors" front panel. The connection to the
amplifier is illustrated by cable # 4 in Figure 16, above.
5.2.3. Connections Specific to the IP02
In the case of the IP02, the two encoders have to be connected. To do so, follow the two
Document Number: 501 Revision: 5.0 Page: 17
IP01 and IP02 User Manual steps described below:
5. Connect the Cart Position "Encoder" Cable
The "Encoder" cable is the 5-pin-stereo-DIN-to-5-pin-stereo-DIN cable described in
Table 8 and shown in Figure 13. First connect one end of the cable to the IP02 Cart
Encoder Connector, which is shown as component # 10 in Figure 3. Then connect
the other cable end to the Encoder Input 0 on your DAQ Terminal Board, as
illustrated by cable # 5 in Figure 16, above.
6. Connect the Pendulum Angle "Encoder" Cable
The "Encoder" cable is the 5-pin-stereo-DIN-to-5-pin-stereo-DIN cable described in
Table 8 and shown in Figure 13. First connect one end of the cable to the IP02
Pendulum Encoder Connector, which is shown as component # 11 in Figure 3.
Then connect the other cable end to the Encoder Input 1 on your DAQ Terminal
Board, as shown by cable # 6 in Figure 16, above.
CAUTION: Any encoder should be directly connected to the data acquisition terminal board using a standard 5-pin DIN cable. DO NOT connect the encoder cable to the
amplifier!
Cable #
1
From
Terminal Board:
Analog Output
#0
To
Amplifier "Amplifier
Command" connector
2
3
Amplifier "To
Load" connector
Amplifier "To
ADC" connector
4 Amplifier "S1 &
S2" connector
IP01_2 "Motor" connector
Terminal Board:
S1 to Analog Input #0
S2 to Analog Input #1
S3 to Analog Input #2
S4 to Analog Input #3
IP01 “S1 & S2” connector
5 Terminal Board:
Encoder Input
#0
“IP02 Cart” encoder connector
Signal
Control signal to the amplifier
Power leads to the IP01_2 DC motor.
Carries the analog signals connected to the S1 & S2, S3, and S4 connectors on the amplifier to the dataacquisition board.
IP01 cart (S1/AI #0) and pendulum
(S2/AI #1) potentiometer measurements.
IP02 cart position measurement.
Document Number: 501 Revision: 5.0 Page: 18
IP01 and IP02 User Manual
Cable #
6
From
Terminal Board:
Encoder Input
#1
To
"IP02 Pendulum" encoder connector
Table 9: IP01_2 system wiring summary when using amplifier.
Signal
IP02 pendulum shaft angle measurement.
5.3. Typical Connections for the IP01/IP02 when using the
Quanser Q3 ControlPAQ-FW
The connections needed on the Q3 ControlPAQ-FW device when using the IP01 are shown
in Figure 17, below. The connection procedure is discussed below and summarized in Table
Figure 17: Connections between IP01_2 and Quanser Q3
ControlPAQ-FW.
Document Number: 501 Revision: 5.0 Page: 19
IP01 and IP02 User Manual
5.3.1. Connections Common to both IP01 And IP02
As both IP01 and IP02 share the same DC motor, the "power" connections for both IP01 and IP02 are identical. These connections are described below:
1. Connect the "To Load" Cable
The "To Load" cable is the 4-pin-DIN-to-6-pin-DIN cable described in Table 8 and
shown in Figure 12. First, connect the cable 4-pin-DIN connector to the IP01 or
socket labelled "MOTORS 0". The connection to the Q3 is illustrated by cable # 1
5.3.2. Connections Specific to the IP01
In the case of the IP01, the two potentiometers have to be connected. To do so, follow the two steps described below:
2. Connect the "From Analog Sensors" Cable
The "From Analog Sensors" cable is the 6-pin-mini-DIN-to-6-pin-mini-DIN cable
described in Table 8 and shown in Figure 14. Connect of the cable from the IP01 S1
& S2 Connector, shown as component # 21 in Figure 6, to the "ANALOG IN"
socket on the front panel of the Q3. The connection to the is illustrated by cable # 2
5.3.3. Connections Specific to the IP02
In the case of the IP02, the two encoders have to be connected. To do so, follow the two steps described below:
3. Connect the Cart Position "Encoder" Cable
The "Encoder" cable is the 5-pin-stereo-DIN-to-5-pin-stereo-DIN cable described in
Table 8 and shown in Figure 13. First connect one end of the cable to the IP02 Cart
Encoder Connector, which is shown as component # 10 in Figure 3. Then connect
the other cable end to the “ENCODERS 0” socket on your Q3, as illustrated by
cable # 3 in Figure 17, above.
4. Connect the Pendulum Angle "Encoder" Cable
The "Encoder" cable is the 5-pin-stereo-DIN-to-5-pin-stereo-DIN cable described in
Table 8 and shown in Figure 13. First connect one end of the cable to the IP02
Pendulum Encoder Connector, which is shown as component # 11 in Figure 3.
Then connect the other cable end to the ENCODERS 1 on your Q3 device, as
Document Number: 501 Revision: 5.0 Page: 20
IP01 and IP02 User Manual
shown by cable # 4 in Figure 17, above.
Cable #
1
2
From
Q3 "Motors 0" connector
Q3 "Analog In" connector
To
IP01_2 "Motor" connector
IP01 “S1 & S2” connector
3 Q3 “Encoders 0” connector
4 Q3 “Encoders 1” connector
“IP02 Cart” encoder connector
"IP02 Pendulum" encoder connector
Table 10: IP01_2 system wiring summary when using Q3.
Signal
Power leads to the IP01_2 DC motor.
IP01 cart (S1/AI #0) and pendulum
(S2/AI #1) potentiometer measurements.
IP02 cart position measurement.
IP02 pendulum shaft angle measurement.
6. Testing and Troubleshooting
The present section, and following subsections, describe some basic functional tests to determine if your IP01 or IP02 is operating normally. It is assumed that the IP01 or IP02 have
QUARC or LabVIEW to read sensor measurements and feed voltages to the motor. See the manual entitled IP01_2 Integration with QUARC to learn how to interface the IP01 or IP02 with QUARC. Alternatively, these tests can be performed with a signal generator and an oscilloscope.
6.1. The IP01 or IP02 DC Motor
6.1.1. Testing
Ensure the IP01_2 motor is operating correctly by going through this procedure:
1. Apply a small voltage (e.g. around 1V) to analog output channel 0 of the terminal board using, for example, the QUARC software.
2. A positive voltage should result in a motion of the cart to the right, when facing the
IP01 or IP02 (i.e. when facing the position and motor pinions in front of the cart, with the cables connected to the back of the cart). Likewise a negative voltage should result in a motion of the cart to the left part of the track, when facing the
IP01 or IP02.
Document Number: 501 Revision: 5.0 Page: 21
IP01 and IP02 User Manual
6.1.2. Troubleshooting
If the motor is not responding to any signals applied, you should:
●
●
●
●
Verify that the power amplifier is functional. For example when using the Quanser
VoltPAQ device, is the green LED lit?
Check that the data-acquisition board is functional, e.g. the green LED on the
Quanser Q2-USB, Q8-USB, or QPID terminal board should be bright green. The
DAQ board fuse may be burnt and need replacement.
Make sure the voltage is actually reaching the motor terminals (use a voltmeter or oscilloscope).
If the motor terminals are receiving the signal and the motor is still not turning, your motor might be damaged and will need to be repaired. Please refer to Section
Obtaining Support on page 24 for information on contacting Quanser for technical
support.
6.2. The IP01 Potentiometers
6.2.1. Testing
Assuming that all the connections in relation to the IP01 have been made as described in
Section Wiring Procedure For The IP01 And IP02, on page 14, you should be able to
measure and monitor the two IP01 potentiometer signals (i.e. S1 and S2). Using a program such as QUARC, the two potentiometer voltages can be traced on scopes and/or displayed on digital meters. On the DAQ board, the cart position potentiometer voltage (i.e. S1) is available on the analog input channel 0 and the pendulum angle potentiometer voltage (i.e.
S2) on the analog input channel 1.
Test the IP01_2 potentiometers with the following procedure
1. Measure analog input channel #0. Pushing manually the IP01 cart to the right side of the track, when facing it, should result in a positive change in the cart position potentiometer voltage, which should gradually increase up to +5V. Likewise, pushing the IP01 cart towards the left side of the track, when facing it, should result in a negative change in the cart position potentiometer voltage, which should gradually decrease down to -5V. Combining this with the observations made in
Section The IP01 or IP02 DC Motor, on page 21, it is seen that a positive motor
voltage results in an increasing cart position potentiometer voltage, and vice-versa.
2. Measure analog input channel #1. Manually rotating the inverted pendulum (or pendulum socket) clockwise (CW), when facing the cart, should result in a positive change in the pendulum potentiometer voltage, gradually increasing to +2.5V.
Likewise, rotating the inverted pendulum counter-clockwise (CCW), when facing
Document Number: 501 Revision: 5.0 Page: 22
IP01 and IP02 User Manual the cart, should result in a negative change in the pendulum potentiometer voltage, gradually decreasing to -2.5V.
6.2.2. Troubleshooting
If one of the potentiometers does not measure correctly, you should:
●
Verify that the power amplifier is functional. For example when using the Quanser
VoltPAQ device, is the green LED lit? Recall that the analog sensor signal goes through the amplifier before going to the data-acquisition device. Therefore the amplifier needs to be turned on to read the potentiometer.
●
●
Check that the data-acquisition board is functional, e.g. the green LED on the
Quanser Q2-USB, Q8-USB, or QPID terminal board should be bright green. If not then the DAC board fuse may be burnt and need replacement.
The power to the amplifier needs to be switched on in order for it to supply both potentiometers with ±12VDC. Ensure that the potentiometer is powered with
±12VDC at the 6-pin-mini-DIN connector, as shown in Figure 9. You should
observe ±5VDC at the cart position potentiometer terminals, and ±12VDC at the pendulum potentiometer terminals. Moreover, if the voltage from the wiper does not change when you rotate the potentiometer shaft (measuring with, for example, a voltmeter or an oscilloscope), your potentiometer may need to be replaced. To
obtain technical assistance, please refer to Section Obtaining Support on page 24 for
information on contacting Quanser.
6.3. The IP02 Encoders
6.3.1. Testing
Assuming that all the connections in relation to the IP02 have been made as described in
Section Wiring Procedure For The IP01 And IP02, on page 14, you should be able to
measure and monitor the two IP02 encoder signals. For example with QUARC, the two encoder counters can be read by the Encoder Input block and displayed in scopes and/or digital meters. The cart encoder signal is available on the encoder input channel 0 and the pendulum encoder signal on the encoder input channel 1.
1. Moving the IP02 cart, when facing it, to the right side of the track should result in a positive change (i.e. increase) in the cart position encoder counts, which should increase at a rate of +4096 counts per revolution of the position pinion. Likewise, moving the IP02 cart, when facing it, towards the left side of the track should result in a negative change in the cart position (i.e. decrease) in the cart position encoder counts, which should decrease at a rate of -4096 counts per revolution of the
Document Number: 501 Revision: 5.0 Page: 23
IP01 and IP02 User Manual
position pinion. Combining this with the observations made in Section The IP01 or
IP02 DC Motor, on page 21, it is seen that a positive motor voltage results in
increasing cart position encoder counts, and vice-versa.
2. Similarly, rotating the IP02 free-falling pendulum (or pendulum socket) counterclockwise (CCW), when facing the cart, should result in a positive change in the pendulum encoder counts, which should increase at a rate of +4096 counts per pendulum revolution. Likewise, rotating the free-falling pendulum clockwise (CW), when facing the cart, should result in a negative change in the pendulum encoder counts, which should decrease at a rate of -4096 counts per pendulum revolution.
Notes: Some data acquisition systems do not measure in quadrature, in which case you will receive a quarter of the expected counts, resulting to a lesser resolution. Other data acquisition systems do measure in quadrature but increment the count by 0.25 (as opposed to having integer number of counts). Therefore, you should know how the system you are using operates. All Quanser counters measure a total of four times the number of encoder lines per rotation. Therefore a 1024-line encoder results in 4096 integer number of counts for every full revolution.
6.3.2. Troubleshooting
If one of the encoders does not measure correctly, you should:
●
Check that the data-acquisition board is functional, e.g. the LED on the Quanser Q2-
USB, Q8-USB, and QPID terminal boards should be bright green. If not, then the
● terminal board or DAC board fuses may be burnt and need replacement.
Check that both the A and B channels from the encoder are properly generated and fed to the data-acquisition device. Using an oscilloscope, there should be two square waves, signals A and B, with a phase shift of 90 degrees. If this is not observed then the encoder may be damaged and need to be replaced. If you believe that your
7. Obtaining Support
Note that a support contract may be required to obtain technical support. To obtain support from Quanser, go to http://www.quanser.com
and click on the Tech Support link.
Fill in the form with all requested software version and hardware information and a description of the problem encountered. Submit the form. Be sure to include your email address and a telephone number where you can be reached. A qualified technical support person will contact you.
Document Number: 501 Revision: 5.0 Page: 24
IP01 and IP02 User Manual
Appendix A. DC Motor Specification
Sheet
Document Number: 501 Revision: 5.0 Page: 25
IP01 and IP02 User Manual
Appendix B. Planetary Gearhead
Specification Sheet
Document Number: 501 Revision: 5.0 Page: 26
IP01 and IP02 User Manual
Appendix C. IP01 Cart Potentiometer
Specification Sheet
Document Number: 501 Revision: 5.0 Page: 27
IP01 and IP02 User Manual
Appendix D. IP01 Pendulum
Potentiometer Specification Sheet
Document Number: 501 Revision: 5.0 Page: 28
IP01 and IP02 User Manual
Appendix E. IP02 Encoder
Specification Sheet
Document Number: 501 Revision: 5.0 Page: 29
Advertisement
Key Features
- Precisely machined solid aluminum cart
- High quality DC motor equipped with a planetary gearbox
- Linear bearings
- Rack and pinion mechanism
- Consistent and continuous traction