2 WIRE Switchboard
2 WIRE Switchboard
346310
Front view
Switchboard for 2 WIRE audio and video systems. It provides access to various services
(video door entry system functions, door lock and/or stair light management, and
monitoring of apartment alarms) directly from the keyboard, or using the intuitive
icons menu. The switchboard is supplied with built-in table-top support and has a
7” colour LCD display, receiver and handsfree, dedicated keys for the main functions,
and configurable keys. Programming can be performed directly from the device, or
using a PC with the TiSwitchBoardDevice software installed (supplied). It gives the
possibility of creating a directory of handsets, entrance panels, and switchboard.
the device DOES NOT MANAGE secondary EPs and apartment EPs (connected
downstream the apartment interface 346850). The use of additional power supply
is recommended.
It is possible to connect up to maximum 16 switchboards (configured from 0 to 15).
1
2
3
4
5
WARNING: the switchboard cannot be used in systems with 2 WIRE IP interface
346890.
7
Related items
9
336982 LIVINGLIGHT white series 8 pole socket for table-top installation of the switchboard
336803 (8 poles - frayed) cable for table-top installation of the switchboard
346020 additional 2 DIN modules power supply
15
Technical data
Power supply from SCS BUS: Absorptions from BUS (without additional supply):
- stand by absorption: - max. operating absorption: Absorptions from BUS (with additional supply):
- stand by absorption: - max. operating absorption: Operating temperature: Load of relay contacts: 8
10
12 11
35 mA
450 mA
5 mA
20 mA
5 - 40 °C
24 Vac / 24 Vdc
3 A, cosφ = 1
290 mm
210 mm
Legend
1. Handset
2. 7” colour LCD display for the displaying of the user and programming menu and of
the images recorded by the entrance panel or cameras
3. Microphone
4. Navigation keypad. It enables navigating through the menus, with the possibility
of confirming the selection (OK key)
5. Cancel key
6. Direct call key
7. Door lock release key
8. Directory access key
9. Entrance panel and camera cycling activation key
10.Handsfree key
11.Alarm warning LED
12.Operation status LED:
LED ON (steady)=device in stand-by
LED ON (flashing quickly)=call pending
LED ON (flashing slowly)=busy
13.Alphanumeric key
14.Keypad + legend of configurable functions
15.Loudspeaker
BT00412-c-UK
170 mm
13
6
19 – 27 Vdc
Dimensional data
170 mm
14
TECHNICAL SHEETS
Description
1
346310
Configuration
Rear view
The switchboard must be configured as far as:
1
2
- Setting of the local switchboard address (0 or 1 - 15)
- Setting of the associated entrance panel address (1 - 80)
- Setting of any associated service handset
Two different configuration modes are available:
-directly from the icon menu of the switchboard
-using a PC with the TiSwitchboardDevice software installed (available in the CD supplied)
WARNING: certain specific functions, such as the filling of the directories and the
management of the ringtones, require the configuration to be performed using the PC.
3
4
To transfer the configuration performed using the software or to update the device,
connect the switchboard to the PC using the USB-mini cable.
5
Legend
1.
2.
3.
4.
5.
Mini-USB connector for PC connection
Line termination ON/OFF micro-switch
Clamps for the connection of the 2-WIRE SCS BUS BTicino
Additional power supply connection clamps (1 - 2)
Clamps for the connection of the power supply of the audible signal device
(optional)
Functional notes
The maximum installation distances are the same as for 2 WIRE handsets.
Calls from entrance panels are received by all switchboards connected to the system
(the first switchboard answering takes the call).
Calls from handsets may be managed in two different ways (based on the configuration
of the handsets themselves):
mode 1 – handsets configured with P=0 – the calls from these handsets are received
by all the switchboards of the system (the first switchboard answering takes the call).
BT00412-c-UK
mode 2 – example, Handset configured with P=81 – the calls from these handsets
are only received by the secondary switchboard configured with 1; handsets configured
with P=95 – calls from these Handsets are only received by the secondary handset
configured with 15.
The management of the operating mode (day/night) is only entrusted to the main
switchboard (configured with 0).
2
To enable communication the device must be powered.
346310
TEChNICAL SHEETS
Wiring diagrams
Diagram 1 : Single riser with one Switchboard
346310
Main switchboard configuration = 0
230 Vac
346020
PRI
1- 2
2 1
BUS
NOTES:
– Additional power supply with item 346020 recommended.
– For the functional check and the calculation of absorptions use the
YouDiagram software - which can be downloaded free of charge from
the website www.international.bticino.com - ASSISTANCE AND TOOLS TECHNICAL SOFTWARE.
– For the configuration of the switchboard refer to the documentation
supplied with the product.
F441
OUT1
OUT2
OUT3
IN 1
I N2
IN 3
346000
OUT 4
OUT
IN
IN 4
BUS 2 1
SC S
230V a.c .
BT00412-c-UK
Main EP
(P = 1)
CONT.
3
346310
Wiring diagrams
Diagram 2 : 2 wire multi riser with one Switchboard
Riser 1
Riser 2
346851
F441
OUT1
OUT2
OUT3
346851
346000
346851
OUT1
OUT2
OUT3
IN 1
I N2
IN 3
346000
OUT 4
346851
OUT
OUT
IN
IN
ON
ON
F441
OUT 4
ON
OF F
IN 1
M
I N2
IN 3
IN 4
ON
BUS 2 1
SC S
OFF
M
MOD
15
BUS 2 1
SC S
230V a.c .
25
230 Vac
ON OFF
IN 4
MOD
ON OFF
Riser EP
Riser EP
To other 346851 interfaces
NOTES:
– Additional power supply with item 346020
recommended.
– For the functional check and the calculation
of absorptions use the YouDiagram software which can be downloaded free of charge from
the website www.international.bticino.com ASSISTANCE AND TOOLS - TECHNICAL SOFTWARE.
– For the configuration of the switchboard refer to
the documentation supplied with the product.
346310
230 Vac
346020
PRI
1- 2
BUS
F441
OUT1
OUT2
OUT3
IN 1
I N2
IN 3
346000
OUT 4
OUT
BT00412-c-UK
IN
IN 4
230V a.c .
Main EP
(P = 1)
4
BUS 2 1
SC S
Main switchboard configuration = 0
2 1
346310
Diagram 3 : 2 wire multi riser with several Switchboards
Riser 1
346851
Riser 2
F441
OUT1
OUT2
OUT3
346851
346000
346851
OUT1
OUT2
OUT3
IN 1
I N2
IN 3
346000
OUT 4
346851
OUT
OUT
IN
IN
ON
ON
F441
OUT 4
TEChNICAL SHEETS
Wiring diagrams
ON
OF F
IN 1
M
I N2
IN 3
IN 4
ON
BUS 2 1
SC S
OFF
M
MOD
15
BUS 2 1
SC S
230V a.c .
25
230 Vac
ON OFF
IN 4
MOD
ON OFF
Riser EP
Riser EP
To other 346851 interfaces
NOTES:
– In systems with several switchboards, secondary
switchboards must be powered locally with an
additional power supply item 346020.
– Max. 3 switchboards can be connected to the
audio-video node using a star type connection.
– For the configuration of the switchboard refer to
the documentation supplied with the product.
346310
Main switchboard configuration = 0
230 Vac
346020
PRI
1- 2
2 1
BUS
F441
OUT1
OUT2
OUT3
346000
346310
Secondary switchboard configuration = 1
OUT 4
OUT
IN 1
I N2
IN 3
IN 4
BUS 2 1
SC S
BT00412-c-UK
230 Vac
IN
346020
PRI
230V a.c .
1- 2
Main EP
(P = 1)
BUS
2 1
CONT.
5
IN
OUT
OFF
IN 1
OUT1
ON
IN 3
OUT3
ON
IN 4
OUT 4
Main EP
(P = 1)
I N2
OUT2
IN
OUT
346850
SC S
F441
PS
BUS
TK
BUS
PI
BT00412-c-UK
6
230V a.c .
346830
To Handsets
riser 1
BUS 2 1
346000
230 Vac
BUS 2 1
346000
3499
3499
3499
Switchboard 1
Switchboard 2
Switchboard 3
346841
346841
346841
Switchboard 13
Switchboard 14
Switchboard 15
Switchboard 9
Switchboard 10
Switchboard 11
Switchboard 4
Switchboard 5
Switchboard 6
NOTES:
– In systems with several switchboards, secondary
switchboards must be powered locally with an
additional power supply item 346020.
– For the configuration of the switchboard refer to
the documentation supplied with the product
346841
BUS
BUS
BUS
BUS
346310
346310
346310
346310
PRI
230 Vac
2 1
PRI
230 Vac
Secondary switchboard = 12
2 1
PRI
230 Vac
Secondary switchboard = 8
2 1
PRI
230 Vac
Secondary switchboard = 7
2 1
Main switchboard = 0
1- 2
1- 2
1- 2
1- 2
346020
346020
346020
346020
Wiring diagrams
Diagram 4: 2 wire backbone connection of 16 switchboards
346310
Diagram 5 : Display of alarms from common parts on backbone
Riser 1
Riser 2
346851
346851
346851
ON
ON
Riser 3
346851
346851
346851
ON
OF F
ON
M
ON
OFF
ON
M
MOD
15
ON OFF
TECHNICAL SHEETS
Wiring diagrams
OFF
M
MOD
MOD
25
35
ON OFF
ON OFF
BUS
Main switchboard configuration = 0
346310
230 Vac
F441
OUT1
OUT2
OUT3
346020
346000
OUT 4
PRI
OUT
IN
1- 2
IN 1
I N2
IN 3
IN 4
BUS 2 1
SC S
2 1
230V a.c .
Main EP
(P = 1)
F422
OUT
F422
C
IN
I1
I2
I3
I4
MOD
E46ADCN
=–
=–
=–
=1
=3
BT00412-c-UK
NOTES:
– Additional power supply with item 346020
recommended.
– For the functional check and the calculation of
absorptions use the YouDiagram software - which
can be downloaded free of charge from the website
www.international.bticino.com - ASSISTANCE AND
TOOLS - TECHNICAL SOFTWARE.
– For the configuration of the switchboard refer to
the documentation supplied with the product.
– On the common parts it is possible to connect,
using interface item F422, the contact interfaces
for the management of alarms (max. 9 interfaces)
- e.g. door/window contacts and technical alarms
(gas, water, etc.). Refer to the specific MY HOME
documentation.
– All apartment and common alarms are only managed
by the main switchboard (configured with 0).
230V a.c .
4615
3480
NC pushbutton
NO pushbutton
Technical alarm activation
Z1 = 9
N1 = 1
MOD1 = –
Z2 = –
N2 = –
MOD2 = 1-9
N°
AUX
MOD
T
NC pushbutton
-
C
+
-
N° = 2
AUX = 1-9
MOD = –
Alarm reset
7
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project