HAMEG EMC - SET 2 Datasheet - Test Equipment Solutions Ltd

HAMEG EMC - SET 2 Datasheet - Test Equipment Solutions Ltd
Test Equipment Solutions Datasheet
Test Equipment Solutions Ltd specialise in the second user sale, rental and distribution of
quality test & measurement (T&M) equipment. We stock all major equipment types such as
spectrum analyzers, signal generators, oscilloscopes, power meters, logic analysers etc from
all the major suppliers such as Agilent, Tektronix, Anritsu and Rohde & Schwarz.
We are focused at the professional end of the marketplace, primarily working with customers
for whom high performance, quality and service are key, whilst realising the cost savings that
second user equipment offers. As such, we fully test & refurbish equipment in our in-house,
traceable Lab. Items are supplied with manuals, accessories and typically a full no-quibble 2
year warranty. Our staff have extensive backgrounds in T&M, totalling over 150 years of
combined experience, which enables us to deliver industry-leading service and support. We
endeavour to be customer focused in every way right down to the detail, such as offering free
delivery on sales, covering the cost of warranty returns BOTH ways (plus supplying a loan
unit, if available) and supplying a free business tool with every order.
As well as the headline benefit of cost saving, second user offers shorter lead times, higher
reliability and multivendor solutions. Rental, of course, is ideal for shorter term needs and
offers fast delivery, flexibility, try-before-you-buy, zero capital expenditure, lower risk and off
balance sheet accounting. Both second user and rental improve the key business measure of
Return On Capital Employed.
We are based near Heathrow Airport in the UK from where we supply test equipment
worldwide. Our facility incorporates Sales, Support, Admin, Logistics and our own in-house
Lab.
All products supplied by Test Equipment Solutions include:
- No-quibble parts & labour warranty (we provide transport for UK mainland addresses).
- Free loan equipment during warranty repair, if available.
- Full electrical, mechanical and safety refurbishment in our in-house Lab.
- Certificate of Conformance (calibration available on request).
- Manuals and accessories required for normal operation.
- Free insured delivery to your UK mainland address (sales).
- Support from our team of seasoned Test & Measurement engineers.
- ISO9001 quality assurance.
Test equipment Solutions Ltd
Unit 8 Elder Way
Waterside Drive
Langley
Berkshire
SL3 6EP
T: +44 (0)1753 596000
F: +44 (0)1753 596001
Email: [email protected]
Web: www.TestEquipmentHQ.com
EMC SET 2
EMC Precompliance Set up to 3 GHz
The EMC precompliance set EMC-SET2 includes all necessary instruments to analyse typical EMC
problems. This set contains a spectrum analyzer HMS-X incl. HMS-EMC and HMS-3G option, a
probe set HZ540, the HM6050-2 LISN for line conducted measurements and the HMExplorer
software for EMC precompliance measurements.
HMS-X
Spectrum Analyzer
Frequency range: 100 kHz to 1.6 GHz/3 GHz
Spectral purity greater than -100 dBc/Hz (at 100 kHz)
Sweep from 20 ms to 1000 s
Detectors: auto-, min-/max.-peak, sample, RMS, average, quasi-peak
HM6050-2
Line Impedance Simulation Network
Measurement of Line-conducted Interference within the Range from 9 kHz…30 MHz (CISPR 16)
Switchable Transient Limiter
Artificial Hand Connector
HZ540
The HZ540 Probe Set consists of three active broadband probes for EMI diagnosis.
H-field probe
High-impedance probe
E-field probe
EMC PreCom 2.00
EMC module part of the HMExplorer software for conducting pre-compliance measurements (only
possible with HO720 USB/RS-232 interface card and Windows® 32-bit).
Spectrum Analyzer
1.6 GHz | 3 GHz
HMS-X
HMS-X
HMS-X
1 Basic Unit + 3 Options
Your HMS-X Spectrum Analyzer
You can create your HMS spectrum analyzer by combining a basic unit with any
of three available options. In case of growing requirements, upgrade vouchers
allow you to upgrade your instruments with all options at any point in time.
Key facts
❙
❙
❙
❙
❙
❙
Frequency range: 100 kHz to 1.6 GHz/3 GHz*1
Spectral purity greater than -100 dBc/Hz (at 100 kHz)
SWEEP from 20 ms to 1000 s
Detectors: auto-, min-/max.-peak, sample, RMS, average, quasi-peak*2
Miscellaneous marker/Δmarker and peak functions
Tracking generator*3
Frequency range: 5 MHz to 1.6 GHz/3 GHz*1
Output level: -20 dBm to 0 dBm
❙ Directly export data to USB flash drive, RS-232/USB dual interface
for remote control
❙ Fanless design and fast boot time
3 GHz
HMS-EMC
❙ This option activates all the functions that are
required for EMC precompliance measurements.
The preamplifier option has been integrated into the
new HMS-EMC option.
*1 with HMS-3G (HV212) option
*2 with HMS-EMC (HV213) option
*3 with HMS-TG (HV211) option
HMS-3G
❙ The frequency range is increased from
1.6 GHz to 3 GHz with this option.
HMS-TG
❙ This option activates the tracking generator
in the instrument.
We have used the first-class hardware from our largest HMS spectrum analyzer
and developed a new and flexible instrument concept. It can be individually
configured, combined and upgraded for your applications.
HMS-EMC
HMS-3G
HMS-X
2 HAMEG INSTRUMENTS | HMS-X
HMS-TG
Model overview:
HMS previous models
HMS-X
HMS1000E
HMS-X
-104 dBm to +20 dBm
HMS1000
HMS-X + EMC*
typ. -104 dBm
HMS1010
HMS-X + EMC* + TG
HMS3000
HMS-X + EMC* + 3G
HMS3010
HMS-X + EMC* + 3G + TG
HMS-X with EMC option HMS-X basic unit
Amplitude measurement range -114 dBm to +20 dBm
DANL
typ. -135 dBm
Resolution bandwidth
100 Hz to 1 MHz, 200 kHz (-3 dB),
10 kHz to 1 MHz, 200 kHz (-3 dB)
200 Hz, 9 kHz, 120 kHz, 1 MHz (-6 dB)
Video bandwidth
10 Hz to 1 MHz
1 kHz to 1 MHz
* The preamplifier function is an integral part of the HMS-EMC option
More informationen | www.hameg.com 3
HMS-X upgrade
Precompliance
Upgrade at any time
EMC Precompliance
You can easily upgrade all three available options at any later point in time with
option upgrade vouchers available at your dealer.
Not only do unexpected results in test labs during EMC compliance
measurements translate into extra costs, quite often they also cause a
substantial delay for your project. HAMEG offers effective and cost-efficient
tools for EMC precompliance measurements which allow you to successfully
prevent possible surprises before the actual onset of a problem.
The voucher number and the serial number of your HMS-X instrument enable
you to generate the respective licence key directly on our web page
http://voucher.hameg.com.
Our HMExplorer software for your EMC measurements is included with every
HMS-X spectrum analyzer with activated EMC option.
EMC precompliance sets
HV213
HV211
Activates EMC option
HV212
HV211
HV211
HV211
Unlocks TG
Upgrade to 3 GHz
HMS-X
HMS-X
HAMEG offers product sets for your EMC precompliance
measurements, which include all necessary instruments to
analyse typical EMC problems. Depending on your requirements,
you can choose between a 1 GHz and a 3 GHz combination.
Option code*1
Voucher code*2
EMC option incl. preamplifier
HMS-EMC
HV213
Bandwidth upgrade to 3 GHz
HMS-3G
HV212
Unlock built-in tracking generator
HMS-TG
HV211
*1 available only with purchase of HMS-X basic unit
*2 activate HMS-X options at any time after purchase of HMS-X basic unit
4 HAMEG INSTRUMENTS | HMS-X
Spectrum analyzer HMS-X
1 GHz EMC-SET1
❙
❙
❙
❙
Spectrum analyzer HMS-X incl. HMS-EMC option
Probe set HZ530
Line impedance stabilization network (LISN) HM6050-2
HMExplorer software
HMS-X
HMS-X options
HMExplorer software for EMC
precompliance measurements
HMS-EMC
3 GHz EMC-SET2
Differences to SET1:
❙ HMS-3G option additional
❙ 3 GHz probe set HZ540 instead of HZ530
HMS-X
HMS-EMC
HMS-3G
Line impedance stabilization network
for line conducted measurements
LISN HM6050-2
1 GHz probe set
HZ530
3 GHz probe set
HZ540 (fig. similar)
More informationen | www.hameg.com 5
Accessories
Technical Data
Recommended Accessories
Spectrum analyzer HMS-X
Firmware: ≥ 2.022
(RBW 10 kHz, VBW 1 kHz,
ref. level ≤-30 dBm
10 MHz to 1.6 GHz/3 GHz*1)
Frequency
Frequency range:
100 kHz to 3 GHz
Near-field probe set 3 GHz HZ540 | HZ550
This unit is used to measure the voltage standing wave ratio (VSWR) and
reflection coefficient of a device under test with an impedance of 50 Ω.
Typical test devices include attenuators, terminations, frequency switches,
amplifiers, cables and mixers.
Near field probe set for comparative measurements with built-in preamplifier
covering frequency ranges from 1 MHz to 3 GHz, designed for the 50 Ω
N-connectors of the HMS-X:
❙ E-field probe
❙ H-field probe
❙ High impedance probe
❙ µH-field probe (HZ550)
❙ Radiation probe (HZ550)
Temperature stability:
±2 ppm (0 to 30 °C)
Aging:
±1 ppm/year
(ref. level ≤-20 dBm,
f >30 MHz, RBW ≤100 kHz)
Resolution
1 Hz
Accuracy
±(Frequency x tolerance of reference)
Span setting range:
Basic unit
0 Hz (zero span) and 100 Hz to 3 GHz
*1
Spectral purity, SSB phase noise:
30 kHz from carrier
(500 MHz, +20 to 30 °C)
<-85 dBc/Hz*2
100 kHz from carrier
(500M Hz, +20 to 30 °C)
<-100 dBc/Hz
(2 to 3 GHz)
-55 dBc*1
(mixer level -40 dBm)
Miscellaneous
Display:
-80 to +20 dBm in 1 dB steps
Display range
100 dB, 50 dB, 20 dB, 10 dB
Span > 0 Hz
20 ms to 1000 s, min. 20 ms/600 MHz
100 Hz to 1 MHz in 1–3 steps, 200 kHz
*2
Logarithmic display scaling
dBm, dBµV, dBmV
Linear display scaling
Percentage of reference level
*2
Measured curves:
1 curve and 1 memory curve
Trace mathematics:
A-B (curve-stored curve), B-A
Detectors:
Auto-, Min-, Max-Peak, Sample, RMS, Average
Tolerance
Quasi-Peak*2
≤300 kHz
±5 % typ.
Failure of level display:
1 MHz
±10 % typ.
(ref. level -50 dBm, 20 to 30 °C)
<1.5 dB, typ. 0.5 dB
Resolution bandwidths (-6 dB): 200 Hz, 9 kHz, 120 kHz, 1 MHz*2
1 kHz to 1 MHz in 1–3 steps
Marker/Deltamarker
10 Hz to 1 MHz in 1–3 steps
*2
HZ46
HZ99
HO730
HO740
HZ530
Amplitude
4 RU 19” rackmount kit
Carrying case for protection
and transport
Ethernet/USB dual interface
card
Interface IEEE-488 (GPIB),
galvanically isolated
Near-field probe set 1 GHz
Display range:
Average noise level displayed up to +20 dBm
Amplitude measurement
range:
Typ. -104 to +20 dBm
Number of marker:
8
Marker functions:
Peak, next peak, minimum,
center = marker, frequency,
reference level = marker level,
all marker on peak
Marker displays:
Max. permissible DC
at HF input:
80 V
Max. power at HF input:
20 dBm, 30 dBm for max. 3 min.
Intermodulation free range:
66 dB typ.
(typ. +13 dBm third-order intercept)
(at distance between signals
≤2 MHz)
60 dB typ. (+10 dBm TOI)
(at distance between signals
>2 MHz)
66 dB typ. (typ. +13 dBm TOI)
Normal (level, log.), delta marker, noise marker
Normal (lin.), (frequency) counter*2
Typ. -114 to +20 dBm
*2
6 HAMEG INSTRUMENTS | HMS-X
16.5 cm (6.5") TFT Color VGA Display
Save/Recall memory
10 complete device settings
Trigger
Free run, Single Trigger, external Trigger
Video Trigger*2
linear*2
2 ms to 100 s
TOI products, 2 x -20 dBm
(-10 dBm ref. level)
AM and FM (internal speaker)
Interfaces:
Dual-Interface USB/RS-232 (HO720),
USB-Stick (frontside),
USB-Printer (rear side),
DVI-D for ext. monitor
Power supply:
105/253 V, 50 to 60 Hz, CAT II
Power consumption:
Max. 40 W at 230 V, 50 Hz
Protection class:
Safety class I (EN61010-1)
Operating temperature:
+5 to +40 °C
Storage temperature:
-20 to +70 °C
Rel. humidity:
5 to 80 % (non condensing)
Dimensions (W x H x D):
285 x 175 x 220 mm
Weight:
3.6 kg
-60 dBc typ.
Reference level
<-120 dBc/Hz
Span = 0 Hz
Video bandwidths:
3.5 mm DIN jack
Level display:
Resolution bandwidths (-3 dB): 10 kHz to 1 MHz in 1–3 steps, 200 kHz
3 GHz VSWR bridge for HMS-X, option HMS-TG required, option HMS-3G recommended
10 dBm
Demodulation
<-80 dBm
-70 dBc typ.
10 MHz
Essential level (50 Ω)
Audio output (Phone):
typ. -124 dBm*2
(Mixer level ≤-40 dBm,
carrier offset >1 MHz)
Inputs/Outputs
HF Input:
N socket
Input impedance
50 Ω
VSWR
(10 MHz to 1.6 GHz/3 GHz*1)
<1.5 typ.
Output tracking generator*3:
N socket
Output impedance
50 Ω
Frequency range
5 MHz to 1.6 GHz/3 GHz*1
Output level
-20 to 0 dBm, in 1 dB steps
BNC females
Reference frequency
Supply output for field probes: 6 Vdc, max. 100 mA (2.5 mm DIN jack)
2nd harmonic receive frequency:
Sweep time:
Same specification as
HZ540 | HZ550, but with low
capacitance probe instead of
high impedance probe
-95 dBm, typ. -104 dBm
Input related spurious:
0 Hz (zero span) and 100 Hz to 1.6 GHz
TTL
Ext. reference input/output:
Inherent spurious:
Frequency counter*2:
1 MHz from carrier
(500MHz, +20 to 30 °C)
Alternative version
HZ540L | HZ550L
Preamp. deactivated
BNC female
Trigger voltage
(RBW 100 Hz, VBW 10 Hz,
Ref. Level ≤-30 dBm 10 MHz
to 1.6 GHz/3 GHz*1)
-115 dBm*2, typ. -135 dBm*2
100 kHz to 1.6 GHz
*1
3 GHz VSWR bridge HZ547
Trigger input:
DANL (Displayed average noise level):
*1
with activated HMS-3G option
*2
with activated HMS-EMC option
*3
with activated HMS-TG option
Accessories included:
Line cord, printed operating manual, CD, software
Recommended accessories:
HO730
Dual-interface ethernet/USB
HO740
Interface IEEE-488 (GPIB), galvanically isolated
HZ530
Near-field probe set 1 GHz for EMI diagnostics
HZ540/550
Near-field probe set 3 GHz for EMI diagnostics
HZ540L/550L Near-field probe set 3 GHz for EMI diagnostics
HZ547
3 GHz VSWR bridge for HMS-X incl. HMS-TG option
HZ13
Interface cable (USB) 1.8 m
HZ14
Interface cable (serial) 1:1
HZ21
Adapter N (plug) - BNC (socket)
HZ46
4RU 19” rackmount kit
HZ72
GPIB-cable 2 m
HZ99
Carrying case for protection and transport
HZ520
Plug-in antenna with BNC connection
HZ525
50 Ω-termination, N plug
HZ560
Transient limiter
HZ575
75/50 Ω converter
More information | www.hameg.com 7
HM6050-2
Line Impedance Stabilization Network
HM6050-2
R M
easurement of Line-conducted Interference
within the Range from 9 kHz…30 MHz (CISPR 16)
R Switchable Transient Limiter
HM6050-2K
(UK Version, 230 V)
HM6050-2S
(US Version, 115 V)
R Artificial Hand Connector
Technical Specifications at 23 °C ±2 °C
Frequency Range:
Impedance Characteristics:
Measurement
of Line-conducted
Interference: Fail
Measurement
of Line-conducted
Interference: Pass
Max. Current:
Line Voltage/Frequency:
Artificial Hand:
PE (switchable):
9 kHz…30 MHz
= 50 Ω || (50 µH + 5 Ω),
Z
Error <20 % under terms of VDE 876T1
16 A
230 V/50…60 Hz, CAT II
220 pF + 511 Ω
50 µH || 50 Ω
Transient Limiter
Frequency Range:
Transmission Loss:
150 kHz…30 MHz
10 dB (+1.5/-0.5 dB)
Connectors
Measurement Output:
Power Supply Socket for DUT:
Artificial Hand:
Power Cable:
50 Ω BNC
Standard German (UK, US) electrical cases
4 mm banana socket
fixed
Miscellaneous
Operating Temperature:
Power Supply:
Safety Class:
Dimensions and Weight:
10…40 °C
HM6050-2D (DE Version) 230 V ±10 %, 50…60 Hz
HM6050-2K (UK Version) 230 V ±10 %, 50…60 Hz
HM6050-2S (US Version) 115 V ±10 %, 50…60 Hz
Safety class I (IEC1010-1/VDE 0411)
285 x 125 x 380 mm (W x H x D), approx. 6 kg
HM6050-2E/121010 · C&E · Subject to change without notice · © HAMEG Instruments GmbH® · DQS-certified in accordance with DIN EN ISO 9001:2008, Reg.-No.: 071040 QM08
HAMEG Instruments GmbH · Industriestr. 6 · D-63533 Mainhausen · Tel +49 (0) 6182 8000 · Fax +49 (0) 6182 800100 · www.hameg.com · [email protected]
HZ540/HZ550 EMV Near-Field Probe Set up to 3GHz
HZ540 and HZ550 EMI-Near Field Probe Sets
HZ550
The HZ540/550 are the ideal toolkits for the investigation of RF electromagnetic fields. They are indispensable for EMI pre-compliance testing during product
development, prior to third party testing. The sets
include 3 or 5 hand-held probes with built-in preamplifier covering the frequency range from <1 MHz
to approx. 3000 MHz.
The probes of the basic set HZ540 include one mag­
netic field probe, one electric field probe, and a high
impedance probe. In addition to the HZ550 features an
optional µ-magnetic field probe and an antenna. All
probe outputs are matched to the 50 Ω inputs of spectrum analyzers or RF-receivers.
Picture
HZ550L
Probe Set HZ540 (Basic Set)
HZ551
Frequency range:
Directional sensitivity:
Output impedance:
Power supply:
HZ552
Frequency range:
Directional sensitivity:
Output impedance:
Power supply:
HZ553
Frequency range:
Input capacity:
Attenuation:
Max. input voltage:
Max. voltage of a
non-insulated conductor:
Output impedance:
Power supply:
Physical dimensions:
HZ540 consists of:
Probe Set HZ550
Electrical Field Probe
<1 MHz to approx. 3 GHz
omnidirectional
Sensitive to electrical fields
50 Ω; SMA-connector
6 Vdc /80 mA
(directly from HAMEG Spectrum
Analyzer)
HZ554
Frequency range:
Directional sensitivity:
Magnetic Field Probe
<30 MHz to approx. 3 GHz
similar to a frame antenna
Sensitive to changing magnetic fields
50 Ω; SMA-connector
6 Vdc /50 mA
(directly from HAMEG Spectrum
Analyzer)
HZ556
Frequency range:
Directional pattern:
High Impedance Probe
<1 MHz to approx. 3 GHz
<2 pF II approx. 250 kΩ
between 10:1 and 30:1
10 Vpp (without significant distortion)
HZ550 consists of:
30 V
50 Ω; SMA-connector
6 Vdc /80 mA
(directly from HAMEG Spectrum
Analyzer)
13 x 27 x 70 mm (W x H x D)
(+ antenna at HZ551)
HZ551 Electrical Field Probe
HZ552 Magnetic Field Probe
HZ553 High Impedance Probe
1 SMA to N-Cable 1.2 m
Case
Manual
Max. voltage of a
non-insulated conductor:
Output impedance:
Power supply:
Max. input power:
Output impedance:
Power supply:
Physical dimensions:
Magnetic Field Probe (small sensor)
<50 MHz to approx. 3 GHz
Sensitive to chan­ging magnetic fields
High spatial re­so­lution due to very
small sensor area
30 V
50 Ω; SMA-connector
6 Vdc /50 mA
Active antenna
<30 MHz to approx. 3 GHz
like a frame antenna
Radiation of changing magnetic fields
0.5 W (short term)
50 Ω; SMA-connector
not required; passive probe
13 x 27 x 70 mm (W x H x D)
(+ antenna at HZ551)
1 HZ540 Basic Set
1 HZ554 Magnetic Field Probe
1 HZ556 Active antenna
1 SMA to N-Cable 1.2 m
Probe Set HZ540L and HZ550L
HZ540L = HZ540 (without HZ553) + HZ555 Low Capacitance Probe
HZ550L = HZ550 (without HZ553) + HZ555 Low Capacitance Probe
HZ555
Frequency range:
Input impedance:
Attenuation:
Max. input voltage:
Max. voltage of a
non-insulated conductor:
Output impedance:
Power supply:
Low Capacitance Probe
approx. 400 kHz…3 GHz
<0.2 pF // 250 kΩ
10:1
5 Vpp
30 V
50 Ω; SMA-connector
6 Vdc /80 mA
HZ540/HZ550E/250112 · C&E · Subject to change without notice · © HAMEG Instruments GmbH® · DQS-certified in accordance with DIN EN ISO 9001:2008, Reg.-No.: 071040 QM08
HAMEG Instruments GmbH · Industriestr. 6 · D-63533 Mainhausen · Tel +49 (0) 6182 8000 · Fax +49 (0) 6182 800100 · www.hameg.com · [email protected]
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF