MARINE AIR-CONDITIONING, HEATING

AND VENTILATION SYSTEMS

HVAC Catalogue

MAR-IX IS A PRODUCT FROM MAVÉ B.V. WWW.MAVE.NL

English

MARINE AIR-CONDITIONING, HEATING AND VENTILATION SYSTEMS

CONTENTS

Self contained units

Airco chiller units

Clima chiller units

Airco inverter chiller units

Clima inverter chiller units

Hydraulic driven chiller units

Reversed cycle chiller units

Fan coil units

Defroster units

Air handling units

Accessories

System possibilities

Compositions

Application form

16

18

12

14

33

08

10

04

06

39

46

34

36

55

3

Self Contained Units

The self contained unit is a complete air conditioning system. It is a compact system that can easily cool any given chamber.

This compact system includes all cool technical components that an air-conditioning unit requires to cool a single compartment, such as the seawater cooled condenser, compressor and evaporator.

This unit can be easily installed in the compartment without being entirely visible.

Included with this system are all basic necessary components such as the seawater pump and the thermostat. These items are required to secure a fully functioning air conditioning system.

MARINE AIR-CONDITIONING, HEATING AND VENTILATION SYSTEMS

Technical features

- equipped with rotary compressor

- filled with environment friendly R407C refrigerant

- mainly manufactured from stainless steel

- sea water resistant condenser

- sea water resistant water pump

- standard equipped with vibration absorbers

- pressure and temperature protected

- low current

- air outlet horizontally or vertically adjustable

Standard supply

- self contained unit

- manual

- sea water pump

- sea water strainer

- digital thermostat

- isolated airhose

- skin fittings

Voltage

Cool capacity

Refrigerant

Current

Max. air flow

Airhose connection

Dimensions (lxwxh)

Weight

Price

4

Self contained units

SCU2

230V 50Hz-AC* and 12-24VDC

2 kW (6.800Btu)

R407C

3A

350 m³/h

Ø 100 mm

447 x 216 x 354 mm

27 kg

€ 1.699,-

SCU3

230V 50Hz-AC* and 12-24VDC

3 kW (10.200Btu)

R407C

4,5A

650 m³/h

Ø 150 mm

506 x 216 x 354 mm

31 kg

€ 1.865,-

* 230V/60Hz-AC on request

MARINE AIR-CONDITIONING, HEATING AND VENTILATION SYSTEMS

See page 46 for an example composition.

SCU2

2kW (6.800Btu)

SCU3

3kW (10.200Btu)

Self contained units

5

Airco Chiller Unit

An airco chiller unit is a system which can be installed in the engine compartment.

This chiller unit supplies a tubing circuit through the boat with cold water (glycol). This fluid flows through the fan coil units (through which air is flowing at the same time) and as a result it cools the surrounding areas.

This system can cool any given area, the temperature can be controlled and adjusted separately.

The sum of the capacity of the fan coil units, which have to function at the same time, results in the total capacity of the airco chiller unit.

A complete chiller system consists of the airco chiller unit, fan coil units and thermostats.

MARINE AIR-CONDITIONING, HEATING AND VENTILATION SYSTEMS

Technical features

- equipped with rotary compressors

- filled with environment friendly R407C refrigerant

- mainly manufactured from stainless steel

- sea water resistant condenser

- sea water resistant water pump

- standard equipped with vibration absorbers

- pressure and temperature protected

- low current

- quiet operation

- compact system

Standard supply

- the chiller unit

- manual

- circulation pump

- sea water pump

- sea water strainer

- reservoir or expansion tank

- all required fluid connectors

- skin fittings

Voltage

Cool capacity

Refrigerant

Number of compressors

Current

Dimensions (lxwxh)

Weight

Price

A5

230V 50Hz-AC* and 12-24VDC

5 kW (17.000Btu)

R407C

1

5A

268 x 387 x 418 mm

41 kg

€ 3.610,-

A10

230V 50Hz-AC* and 12-24VDC

10 kW (34.100Btu)

R407C

2

10A

513 x 387 x 418 mm

79 kg

€ 5.135,-

A15

230V 50Hz-AC* and 12-24VDC

15 kW (51.200Btu)

R407C

3

15A

758 x 387 x 418 mm

115 kg

€ 6.870,-

* 230V/60Hz-AC on request

6

Airco chiller units

MARINE AIR-CONDITIONING, HEATING AND VENTILATION SYSTEMS

See page 47 for an example composition.

A5

5kW (17.000Btu)

A10

10kW (34.100Btu)

A15

15kW (51.200Btu)

Airco chiller units

7

Clima Chiller Unit

A clima chiller unit is a system which can be installed in the engine compartment.

This chiller unit supplies a tubing circuit through the boat with cold or warm water (glycol). This fluid flows through the fan coil units (through which air is flowing at the same time) and as a result it can either cool down or heat up the surrounding areas.

This system can control the temperature in any given compartment separately.

The sum of the capacity of the fan coil units, which have to function at the same time, results in the total capacity of the clima chiller unit.

The integrated diesel heater is the main source for heating the system.

A complete chiller system consists of the clima chiller unit, fan coil units and thermostats.

MARINE AIR-CONDITIONING, HEATING AND VENTILATION SYSTEMS

Technical features

- equipped with rotary compressors

- filled with environment friendly R407C refrigerant

- mainly manufactured from stainless steel

- sea water resistant condenser

- sea water resistant water pump

- standard equipped with vibration absorbers

- pressure and temperature protected

- low current

- quit operation

- compact system

Standard supply

- the chiller unit

- manual

- circulation pump

- sea water pump

- sea water strainer

- reservoir or expansion tank

- all required fluid connectors

- skin fittings

Voltage

Cool capacity

Refrigerant

Number of compressors

Current AC

Heat capacity

Current DC

Dimensions (lxwxh)

Weight

Price

C5

230V 50Hz-AC* and 12-24VDC

5 kW (17.000Btu)

R407C

1

5A

5 kW (diesel)

10-37W

268 x 387 x 511 mm

45 kg

€ 5.400,-

C10

230V 50Hz-AC* and 12-24VDC

10 kW (34.100Btu)

R407C

2

10A

9 kW (diesel)

36-125W

513 x 514 x 418 mm

90 kg

€ 7.145,-

C15

230V 50Hz-AC* and 12-24VDC

15 kW (51.200Btu)

R407C

3

15A

9 kW (diesel)

36-125W

758 x 514 x 418 mm

130 kg

€ 8.920,-

* 230v/60Hz-ac on request

8

Clima chiller units

MARINE AIR-CONDITIONING, HEATING AND VENTILATION SYSTEMS

Zie pagina 48 voor een voorbeeld samenstelling.

C5

Koel vermogen 5kW (17.000Btu)

Verwarmend vermogen 5kW

C10

Koel vermogen 10kW (34.100Btu)

Verwarmend vermogen 10kW

C15

Koel vermogen 15kW (51.200Btu)

Verwarmend vermogen 10kW

Clima chiller units

9

Airco Inverter Chiller Units

An airco inverter chiller unit is a system which can be installed in the engine compartment.

This chiller unit will control its capacity according to what is being demand in its surroundings, due to the applied inverter compressor technology.

There is no current peak when switching on the compressor.

The chiller unit supplies cold water (glycol) which flows through a tubing circuit and fan coil units, (through which air is flowing at the same time) and as a result it cools the surrounding areas.

This system can cool any given area/cabin and the temperature and airflow can be controlled and adjusted separately.

The sum of the capacity of the fan coil units, which have to function at the same time, results in the total capacity of the chiller unit.

A complete system consists of the chiller unit, fan coil units and thermostats.

MARINE AIR-CONDITIONING, HEATING AND VENTILATION SYSTEMS

Technical features

- equipped with variable capacity rotary compressor

- filled with environment friendly R410A refrigerant

- mainly manufactured from stainless steel

- sea water resistant condensor

- sea water resistant water pump

- standard equipped with vibration absorbers

- pressure and temperature protected

- low current

- quit operation

- variable cool capacity

- compact system

- no current peak at start-up

- energy saving

Standard supply

- the chiller unit

- manual

- circulation pump

- sea water pump

- sea water strainer

- all required fluid connectors

- skin fittings

Voltage

Cool capacity

Refrigerant

Current

Dimensions (lxwxh)

Weight

Price

Voltage

Cool capacity

Refrigerant

Current

Dimensions (lxwxh)

Weight

Price

AIV5

230V 50/60Hz-AC and 12-24VDC

1-5kW (3.400-17.000Btu)

R407C

1,5-5A

508 x 257 x 414 mm

39 kg

€ 4.900,-

AIV15

230V 50/60Hz-AC and 12-24VDC

2-15kW (6.800-51.200Btu)

R410A

3-15A

578 x 377 x 515 mm

68 kg

€ 8.100,-

AIV8

230V 50/60Hz-AC and 12-24VDC

2-8kW (6.800-27.300Btu)

R410A

2-8A

508 x 257 x 474 mm

48 kg

€ 5.620,-

AIV20

380-440V 50/60Hz

L3+N+Pe and 12-24VDC

4-20kW (13.600-68.300)

R410A

7,5A / 400V

678 x 457 x 597 mm

108 kg

€ 13.700,-

AIV10

230V 50/60Hz-AC and 12-24VDC

2-10kW (6.800-34.100Btu)

R410A

2-10A

408 x 387 x 445 mm

47 kg

€ 5.985,-

AIV25

380-440V 50/60Hz

L3+N+Pe and 12-24VDC

4-25kW (13.600-85.300Btu)

R410A

9A / 400V

678 x 457 x 597 mm

110 kg

€ 14.900,-

AIV30

380-440V 50/60Hz

L3+N+Pe and 12-24VDC

4-30kW (13.600-102.300)

R410A

11A / 400V

678 x 457 x 597 mm

114 kg

€ 15.600,-

10

Airco inverter chiller units

MARINE AIR-CONDITIONING, HEATING AND VENTILATION SYSTEMS

See page 49 for an example composition.

AIV5

5kW (17.000Btu)

AIV8

8kW (27.300Btu)

AIV10

10kW (34.100Btu)

AIV15

15kW (51.200Btu)

AIV20/AIV25/AIV30

Airco inverter chiller units

11

MARINE AIR-CONDITIONING, HEATING AND VENTILATION SYSTEMS

Clima Inverter Chiller Units

A clima inverter chiller is a system which can be installed in the engine compartment.

This chiller unit will control its capacity according to what is being demanded in its surroundings due to the applied inverter compressor technology.

There is no current peak when switching on the compressor.

The chiller unit supplies cold/hot water (glycol) which flows through a tubing circuit and fan coil units, (through which air is flowing at the same time) and as a result it cools/heats the surrounding areas.

This system can cool any given area/cabin, and the temperature and airflow can be controlled and adjusted separately.

The sum of the capacity of the fan coil units, which have to function at the same time, results in the total capacity of the chiller unit.

Furthermore this system is equipped with a diesel heater, heat exchanger and boiler function. The heat exchanger can be connected to the cooling system of the main engine or generator, to heat the boiler or the heating system. The boiler function can be connected to the diesel heater or heat exchanger, and is able to function simultaniously with the cooling function.

A complete system consists of the chiller unit, fan coil units and thermostats.

Voltage

Cool capacity

CIV5

230V 50/60Hz-AC and 12-24VDC

1-5 kW

(3.400-17.000Btu)

CIV8

230V 50/60Hz-AC and 12-24VDC

2-8 kW

(6.800-27.300Btu)

Refrigerant

Number of compressors

Current AC

Heat capacity

Current DC

Dimensions (lxwxh)

Weight

Price

R407C

1

1,5-5A

5 kW

10-37W

508 x 371 x 414 mm

52 kg

€ 6.520,-

R410A

1

2-9A

5 kW

10-37W

508 x 371 x 474 mm

61 kg

€ 7.240,-

CIV10-5

230V 50/60Hz-AC and 12-24VDC

2-10 kW

(6.800-34.100Btu)

R410A

1

2-10A

5 kW

10-37W

408 x 501 x 445 mm

62 kg

€ 8.600,-

Technical features

- equipped with variable capacity rotary compressor

- filled with environment friendly R410A refrigerant

- mainly manufactured from stainless steel

- sea water resistant condensor

- sea water resistant water pump

- standard equipped with vibration absorbers

- pressure and temperature protected

- low current

- quit operation

- variable cool capacity

- compact system

- no current peak at start-up

- energy saving

Standard supply

- the chiller unit

- manual

- circulation pump

- sea water pump

- sea water strainer

- reservoir or expansion tank

- all required fluid connectors

- skin fittings

CIV10-10

230V 50/60Hz-AC and 12-24VDC

2-10 kW

(6.800-34.100Btu)

R410A

1

2-10A

10 kW

36-125W

408 x 606 x 435 mm

68 kg

€ 9.100,-

CIV15

230V 50/60Hz-AC and 12-24VDC

3-15 kW

(10.200-51.200Btu)

R410A

1

3-15A

10 kW

36-125W

578 x 517 x 515 mm

88 kg

€ 9.830,-

12

Clima inverter chiller units

MARINE AIR-CONDITIONING, HEATING AND VENTILATION SYSTEMS

See page 50 for an example composition.

CIV5

Cool capacity 5kW (17.000Btu)

Heat capacity 5kW

CIV8

Cool capacity 8kW (27.300Btu)

Heat capacity 5kW

CIV10

Cool capacity 10kW (34.100Btu)

Heat capacity 5kW or 10kW

CIV15

Cool capacity 15kW (51.200Btu)

Heat capacity 10kW

Clima inverter chiller units

13

Hydraulic Driven Chiller Units

The hydraulic driven chiller unit is a system which can be placed in the engine room.

This chiller unit is equipped with a hydraulic driven cool compressor, circulation pump and sea water pump (intergrated).

The system is driven by a hydraulic installation

(usually already present on board) and a battery supply of 24VDC.

This chiller unit supplies a tubing circuit through the boat with cold water (glycol). This fluid flows through the fan coil units (through which air is flowing at the same time) and as a result it cools the surrounding areas.

This system can cool any given area/cabin, and the temperature and airflow can be controlled and adjusted separately.

The sum of the capacity of the fan coil units, which have to function at the same time, results in the total capacity of the chiller unit.

A complete chiller system consists of the hydraulic driven chiller unit, fan coil units and thermostats.

MARINE AIR-CONDITIONING, HEATING AND VENTILATION SYSTEMS

Technical features

- equipped with hydraulic driven compressor, circulation and sea water pump

- filled with environment friendly R134A refrigerant

- mainly manufactured from stainless steel

- sea water resistant condenser

- sea water resistant water pump

- standard equipped with vibration absorbers

- pressure and temperature protected

- compact system

- resistant against rough seas and angles up to 60°

Standard supply

- the hydraulic driven chiller unit

- manual

- the hydraulic driven circulation pump

(intergrated)

- the hydraulic driven sea water pump

(intergrated)

- sea water strainer

- reservoir or expansion tank

- all required fluid connectors

- skin fittings

Voltage

Cool capacity

Refrigerant

Number of compressors

Current

Oil supply

Dimensions (lxwxh)

Weight

Price

14

Hydraulic driven chiller units

HC5

24VDC*

5kW (17.000Btu)

R134A

1

3A

8-12L/min. (at ±150bar)

250 x 460 x 515 mm

40 kg

€ 9.320,-

Spe c ia ll y de s ign e d fo nc e s r e x t r e m e

!

c ir c u ms ta

HC10

24VDC*

10kW (34.100Btu)

R134A

1

3A

10-15L/min (at ±150bar)

260 x 600 x 663 mm

76 kg

€ 11.900,-

* 12VDC on request

HC5

Cool capacity 5kW (17.000Btu)

MARINE AIR-CONDITIONING, HEATING AND VENTILATION SYSTEMS

See page 51 for an example composition.

HC10

Cool capacity 10kW (34.100Btu)

Hydraulic driven chiller units

15

Reversed Cycle Chiller Units

A reversed cycle chiller unit is an alternative current (AC) system (with Reverse Cycle heating system) which can be installed in the engine compartment.

This chiller unit supplies a tubing circuit through the boat with cold or warm water

(glycol). This fluid flows through the fan coil units (through which air is flowing at the same time) and as a result it cools down or heats up the surrounding areas.

This system can control the temperature in any given compartment separately.

The sum of the capacity of the fan coil units, which have to function at the same time, results in the total capacity of the chiller unit.

A complete chiller system consists of the reversed cycle chiller unit, fan coil units and thermostats.

MARINE AIR-CONDITIONING, HEATING AND VENTILATION SYSTEMS

Technical features

- equipped with scroll compressors

- filled with environment friendly R407C refrigerant

- mainly manufactured from stainless steel

- sea water resistant condensor

- sea water resistant water pump

- standard equipped with vibration absorbers

- pressure and temperature protected

- quiet operation

- reverse cycle heating system

Standard supply

- the chiller unit

- manual

- circulation pump

- sea water pump

- sea water strainer

- expansion tank

- all required fluid connectors

- skin fittings

Voltage

Cool capacity

Refrigerant

Current

Heat capacity

Dimensions (lxwxh)

Weight

Price

A15RC

400v 50Hz*

L3+N+Pe and 12-24VDC

15 kW (51.200Btu)

R407C

3.600W

up to 20kW

412 x 660 x 570 mm

105 kg

€ 7.795,-

16

Reversed cycle chiller units

A30RC

400v 50Hz*

L3+N+Pe and 12-24VDC

30 kW (102.400Btu)

R407C

7.200W

up to 40kW

779 x 660 x 570 mm

205 kg

€ 12.550,-

A45RC

400v 50Hz*

L3+N+Pe and 12-24VDC

45 kW (153.600Btu)

R407C

10.800W

up to 60kW

1.146 x 660 x 570 mm

300 kg

€ 15.180,-

* 400v/60Hz-ac on request

MARINE AIR-CONDITIONING, HEATING AND VENTILATION SYSTEMS

See page 52 for an example composition.

A15RC

Cool capacity 15kW (51.200Btu)

Heat capacity up to 20kW

A30RC

Cool capacity 30kW (102.400Btu)

Heat capacity up to 40kW

A45RC

Cool capacity 45kW (153.600Btu)

Heat capacity up to 60kW

Reversed cycle chiller units

17

Fan Coil Units

Fan coil units are the components in a heating and airconditioning system that ensures the transport of energy from hot or cold air.

The MAR-IX fan coil units are designed as compact as possible to minimize the installation space.

The ‘low profile’ (LP) range is designed to be installed in narrow spaces. For example vertically in cabinets or horizontally under seating areas.

The fans used on the units are specially selected to move a large volume of air at low noise to guarantee comfort.

Besides the standard fan coil units it is possible to provide the units with a 24VDC fan, an electric 3-way valve or electric heating.

MARINE AIR-CONDITIONING, HEATING AND VENTILATION SYSTEMS

Technical features

- compact format

- rotatable fan housing

- installation friendly

- high air flow air filter

- quiet operation

- low current

- external electronic device

Available with;

- 3-way valve 230VAC or 24VDC

- electric heating

- 1,5kW (5.800Btu) up to 13kW (40.200Btu)

Standard supply

- the fan coil unit

- manual

- air filter

- electronic connection device

Explanation type numbers

24

V

EL

Equipped with 24VDC fan

Equipped with electric 3-way valve

Equipped with electric heating

Contents fan coil units

1.5kW (5.800Btu)

2kW (6.800Btu)

2kW LP (6.800Btu)

3kW (10.200Btu)

3kW LP (10.200Btu)

2x2kW (13.600Btu)

4kW (13.600Btu)

4kW LP (10.200Btu)

5kW (17.000Btu)

6kW (20.400Btu)

7kW (23.800Btu)

8kW (27.200Btu)

10kW (34.00Btu)

13kW (44.200Btu) page 19 page 20 page 21 page 22 page 23 page 24 page 25 page 26 page 27 page 28 page 29 page 30 page 31 page 32

18

Fan coil units

Fan Coil Units 1.5kW

MARINE AIR-CONDITIONING, HEATING AND VENTILATION SYSTEMS

FC1.5 ELV

Cool capacity

Heat capacity

Elec. heat capacity

Voltage

Current

Type fan

Max. airflow

Airhose connection

Fluid connection

Dimensions (lxwxh)

Weight

Price

Cool capacity

Heat capacity

Elec. heat capacity

Voltage

Current

Type fan

Max. airflow

Airhose connection

Fluid connection

Dimensions (lxwxh)

Weight

Price

10 kg

FC1.5

4kW (80°C water)

-

230VAC 50/60Hz

0,5A

Ø 140 mm

310 m³/h

Ø 100 mm

Ø 16 mm

270 x 210 x 300 mm

5,5 kg

€ 570,-

FC1.5 V-24

1,5kW (5.100Btu)

4kW (80°C water)

-

24VDC

2,5A

Ø 140 mm

310 m³/h

Ø 100 mm

½”G O.D.

310 x 230 x 300

7,5 kg

€ 915,-

9 kg

€ 840,-

FC1.5 - 24

1,5kW (5.100Btu)

4kW (80°C water)

-

24VDC

2,5A

Ø 140 mm

310 m³/h

Ø 100 mm

Ø 16 mm

270 x 210 x 300 mm

5,5 kg

€ 690,-

14 kg

€ 1.060,-

FC1.5 ELV

1,5kW (5.100Btu)

4kW (80°C water)

0,75kW

230VAC 50/60Hz

3,7A

Ø 140 mm

310 m³/h

Ø 100 mm

½”G O.D.

310 x 230 x 300

9 kg

€ 878,-

FC1.5 V

4kW (80°C water)

-

230VAC 50/60Hz

0,5A

Ø 140 mm

310 m³/h

Ø 100 mm

½”G O.D.

310 x 230 x 300

7,5 kg

€ 793,-

FC1.5 ELV-24

1,5kW (5.100Btu)

4kW (80°C water)

0,75kW

24VDC

5,7A

Ø 140 mm

310 m³/h

Ø 100 mm

½”G O.D.

310 x 230 x

9 kg

€ 998,-

Fan coil units

19

Fan Coil Units 2kW

MARINE AIR-CONDITIONING, HEATING AND VENTILATION SYSTEMS

FC2

Cool capacity

Heat capacity

Elec. heat capacity

Voltage

Surrent

Type fan

Max. airflow

Airhose connection

Fluid connection

Dimensions (lxwxh)

Weight

Price

Cool capacity

Heat capacity

Elec. heat capacity

Voltage

Current

Type fan

Max. airflow

Airhose connection

Fluid connection

Dimensions (lxwxh)

Weight

Price

FC2

2kW (6.800Btu)

6kW (80°C water)

-

230VAC 50/60Hz

0,5A

Ø 140 mm

350 m³/h

Ø 100 mm

Ø 16 mm

340 x 210 x 300 mm

6,4 kg

€ 620,-

FC2 V-24

2kW (6.800Btu)

6kW (80°C water)

-

24VDC

2,5A

Ø 140 mm

350 m³/h

Ø 100 mm

½”G O.D.

380 x 230 x 300

8,4 kg

€ 965,-

20

Fan coil units

FC2 ELV

FC2 - 24

2kW (6.800Btu)

6kW (80°C water)

-

24VDC

2,5A

Ø 140 mm

350 m³/h

Ø 100 mm

Ø 16 mm

340 x 210 x 300 mm

6,4 kg

€ 740,-

FC2 ELV

2kW (6.800Btu)

6kW (80°C water)

1kW

230VAC 50/60Hz

4,8A

Ø 140 mm

350 m³/h

Ø 100 mm

½”G O.D.

380 x 230 x 300

9,9 kg

€ 928,-

FC2 V

2kW (6.800Btu)

6kW (80°C water)

-

230VAC 50/60Hz

0,5A

Ø 140 mm

350 m³/h

Ø 100 mm

½”G O.D.

380 x 230 x 300

8,4 kg

€ 845,-

FC2 ELV-24

2kW (6.800Btu)

6kW (80°C water)

1kW

24VDC

6,8A

Ø 140 mm

350 m³/h

Ø 100 mm

½”G O.D.

380 x 230 x 300

9,9 kg

€ 1.048,-

MARINE AIR-CONDITIONING, HEATING AND VENTILATION SYSTEMS

Fan Coil Units 2kW ‘low profile’

FC2LP V

Cool capacity

Heat capacity

Elec. heat capacity

Voltage

Current

Type fan

Max. airflow

Airhose connection

Fluid connection

Dimensions (lxwxh)

Weight

Price

FC2LP

2kW (6.800Btu)

6kW (80°C water)

-

230VAC 50/60Hz

0,5A

Ø 140 mm

350 m³/h

Ø 100 mm

Ø 16 mm

340 x 160 x 510

8,3 kg

€ 840,-

FC2LP - 24

2kW (6.800Btu)

6kW (80°C water)

-

24VDC

2,5A

Ø 140 mm

350 m³/h

Ø 100 mm

Ø 16 mm

340 x 160 x 510

8,3 kg

€ 960,-

FC2LP V

2kW (6.800Btu)

6kW (80°C water)

-

230VAC 50/60Hz

0,5A

Ø 140 mm

350 m³/h

Ø 100 mm

½”G O.D.

380 x 160 x 510

10,3 kg

€ 1.163,-

FC2LP V-24

2kW (6.800Btu)

6kW (80°C water)

-

24VDC

2,5A

Ø 140 mm

350 m³/h

Ø 100 mm

½”G O.D.

380 x 160 x 510

10,3 kg

€ 1.055,-

Fan coil units

21

Fan Coil Units 3kW

MARINE AIR-CONDITIONING, HEATING AND VENTILATION SYSTEMS

FC3 ELV

Cool capacity

Heat capacity

Elec. heat capacity

Voltage

Current

Type fan

Max. airflow

Airhose connection

Fluid connection

Dimensions (lxwxh)

Weight

Price

Cool capacity

Heat capacity

Elec. heat capacity

Voltage

Current

Type fan

Max. airflow

Airhose connection

Fluid connection

Dimensions (lxwxh)

Weight

Price

FC3

3kW (10.200Btu)

10kW (80°C water)

-

230VAC 50/60Hz

0,5A

Ø 220 mm

650 m³/h

Ø 150 mm

Ø 16 mm

440 x 210 x 340 mm

9,3 kg

€ 810,-

FC3 V-24

3kW (10.200Btu)

10kW (80°C water)

-

24VDC

4,4A

Ø 220 mm

650 m³/h

Ø 150 mm

½”G O.D.

480 x 250 x 320

11,3 kg

€ 1.185,-

22

Fan coil units

FC3 ELV

FC3 - 24

3kW (10.200Btu)

10kW (80°C water)

-

24VDC

4,4A

Ø 220 mm

650 m³/h

Ø 150 mm

Ø 16 mm

440 x 210 x 340 mm

9,3 kg

€ 960,-

FC3 ELV

3kW (10.200Btu)

10kW (80°C water)

1,5kW

230VAC 50/60Hz

7A

Ø 220 mm

650 m³/h

Ø 150 mm

½”G O.D.

480 x 250 x 320

12,8 kg

€ 1.118,-

FC3 V

3kW (10.200Btu)

10kW (80°C water)

-

230VAC 50/60Hz

0,5A

Ø 220 mm

650 m³/h

Ø 150 mm

½”G O.D.

480 x 250 x 320

11,3 kg

€ 1.033,-

FC3 ELV-24

3kW (10.200Btu)

10kW (80°C water)

1,5kW

24VDC

10,9A

Ø 220 mm

650 m³/h

Ø 150 mm

½”G O.D.

480 x 250 x 320

12,8 kg

€ 1.238,-

MARINE AIR-CONDITIONING, HEATING AND VENTILATION SYSTEMS

Fan Coil Units 3 kW ‘low profile’

FC3LP

Cool capacity

Heat capacity

Elec. heat capacity

Voltage

Current

Type fan

Max. airflow

Airhose connection

Fluid connection

Dimensions (lxwxh)

Weight

Price

FC3LP

3kW (10.200Btu)

10kW (80°C water)

-

230VAC 50/60Hz

0,5A

Ø 220 mm

650 m³/h

Ø 150 mm

Ø 16 mm

440 x 170 x 630 mm

13,7 kg

€ 1.060,-

FC3LP - 24

3kW (10.200Btu)

10kW (80°C water)

-

24VDC

4,4A

Ø 220 mm

650 m³/h

Ø 150 mm

Ø 16 mm

440 x 170 x 630

13,7 kg

€ 1.210,-

FC3LP V

3kW (10.200Btu)

10kW (80°C water)

-

230VAC 50/60Hz

0,5A

Ø 220 mm

650 m³/h

Ø 150 mm

½”G O.D.

480 x 170 x 630

15,7 kg

€ 1.383,-

FC3LP V-24

3kW (10.200Btu)

10kW (80°C water)

-

24VDC

4,4A

Ø 220 mm

650 m³/h

Ø 150 mm

½”G O.D.

480 x 170 x 630

15,7 kg

€ 1.503,-

Fan coil units

23

Fan Coil Units 2x2kW

MARINE AIR-CONDITIONING, HEATING AND VENTILATION SYSTEMS

FC2x2 V

Cool capacity

Heat capacity

Elec. Heat capacity

Voltage

Current

Type fan

Max. airflow

Airhose connection

Fluid connection

Dimensions (lxwxh)

Weight

Price

Cool capacity

Heat capacity

Elec. Heat capacity

Voltage

Current

Type fan

Max. airflow

Airhose connectioon

Fluid connection

Dimensions (lxwxh)

Weight

Price

FC2x2

4kW (13.600Btu)

12kW (80°C water)

-

230VAC 50/60Hz

1A

Ø 2 x 140mm

2 x 350 m³/h

2 x Ø 100 mm

Ø 16 mm

565 x 210 x 300 mm

10 kg

€ 885,-

FC2x2 V-24

4kW (13.600Btu)

12kW (80°C water)

-

24VDC

5A

Ø 2 x 140mm

2 x 350 m³/h

2 x Ø 100 mm

½”G O.D.

605 x 230 x 300

12 kg

€ 1,348,-

24

Fan coil units

FC2x2 - 24

4kW (13.600Btu)

12kW (80°C water)

-

24VDC

5A

Ø 2 x 140mm

2 x 350 m³/h

2 x Ø 100 mm

Ø 16 mm

565 x 210 x 300 mm

10 kg

€ 1.125,-

FC2x2 ELV

4kW (13.600Btu)

12kW (80°C water)

2kW

230VAC 50/60Hz

9,6A

Ø 2 x 140mm

2 x 350 m³/h

2 x Ø 100 mm

½”G O.D.

605 x 230 x 300

15 kg

€ 1.278,-

FC2x2 V

FC2x2 V

4kW (13.600Btu)

12kW (80°C water)

-

230VAC 50/60Hz

1A

Ø 2 x 140mm

2 x 350 m³/h

2 x Ø 100 mm

½”G O.D.

605 x 230 x 300

12 kg

€ 1.108,-

FC2x2 ELV-24

4kW (13.600Btu)

12kW (80°C water)

2kW

24VDC

13,6A

Ø 2 x 140mm

2 x 350 m³/h

2 x Ø 100 mm

½”G O.D.

605 x 230 x 300

15 kg

€ 1.518,-

Fan Coil Units 4kW

MARINE AIR-CONDITIONING, HEATING AND VENTILATION SYSTEMS

FC4 ELV

Cool capacity

Heat capacity

Elec. heat capacity

Voltage

Current

Type fan

Max. airflow

Airhose connectioon

Fluid connectioon

Dimensions (lxwxh)

Weight

Price

Cool capacity

Heat capacity

Elec. heat capacity

Voltage

Current

Type fan

Max. airflow

Airhose connection

Fluid connection

Dimensions (lxwxh)

Weight

Price

FC4

4kW (13.600Btu)

15kW (80°C water)

-

230VAC 50/60Hz

0,9A

Ø 225 mm

850 m³/h

Ø 180 mm

Ø 16 mm

510 x 240 x 350 mm

12,5 kg

€ 915,-

FC4 V-24

4kW (13.600Btu)

15kW (80°C water)

-

24VDC

4A

Ø 225 mm

850 m³/h

Ø 180 mm

½”G O.D.

555 x 290 x 330

14,5 kg

€ 1.340,-

FC4 ELV

FC4 - 24

4kW (13.600Btu)

15kW (80°C water)

-

24VDC

4A

Ø 225 mm

850 m³/h

Ø 180 mm

Ø 16 mm

510 x 240 x 350 mm

12,5 kg

€ 1.115,-

FC4 ELV

4kW (13.600Btu)

15kW (80°C water)

2kW

230VAC 50/60Hz

9,6A

Ø 225 mm

850 m³/h

Ø 180 mm

½”G O.D.

555 x 290 x 330

16 kg

€ 1.223,-

FC4 V

4kW (13.600Btu)

15kW (80°C water)

-

230VAC 50/60Hz

0,9A

Ø 225 mm

850 m³/h

Ø 180 mm

½”G O.D.

555 x 290 x 330

14,5 kg

€ 1.125,-

FC4 ELV-24

4kW (13.600Btu)

15kW (80°C water)

2kW

24VDC

12,7A

Ø 225 mm

850 m³/h

Ø 180 mm

½”G O.D.

555 x 290 x 330

16 kg

€ 1.343,-

Fan coil units

25

MARINE AIR-CONDITIONING, HEATING AND VENTILATION SYSTEMS

Fan Coil Units 4kW ‘low profile’

FC4LP (horizontal)

Cool capacity

Heat capacity

Elec. heat capacity

Voltage

Current

Type fan

Max. airflow

Airhose connection

Fluid connection

Dimensions (lxwxh)

Weight

Price

FC4LP

4kW (13.600Btu)

15kW (80°C water)

-

230VAC 50/60Hz

0,9A

Ø 225 mm

850 m³/h

Ø 180 mm

Ø 16 mm

500 x 180 x 645 mm

17 kg

€ 1.240,-

FC4LP - 24

4kW (13.600Btu)

15kW (80°C water)

-

24VDC

4A

Ø 225 mm

850 m³/h

Ø 180 mm

Ø 16 mm

500 x 180 x 645 mm

17 kg

€ 1.440,-

FC4LP V

4kW (13.600Btu)

15kW (80°C water)

-

230VAC 50/60Hz

0,9A

Ø 225 mm

850 m³/h

Ø 180 mm

½”G O.D.

550 x 180 x 645

19 kg

€ 1.563,-

26

Fan coil units

FC4LP V-24

4kW (13.600Btu)

15kW (80°C water)

-

24VDC

4A

Ø 225 mm

850 m³/h

Ø 180 mm

½”G O.D.

550 x 180 x 645

19 kg

€ 1.687,-

Fan Coil Units 5kW

MARINE AIR-CONDITIONING, HEATING AND VENTILATION SYSTEMS

FC5 (upper outlet)

FC5

Type fan

Max. airflow

Airhose connection

Fluid connection

Dimensions (lxwxh)

Weight

Price

Cool capacity

Heat capacity

Elec. heat capacity

Voltage

Current

Type fan

Max. airflow

Airhose connection

Fluid connection dimensions (lxwxh)

Weight

Price

Ø 225 mm

850 m³/h

Ø 180 mm

Ø 16 mm

500 x 260 x 330

13,7 kg

€ 1.128,-

FC5 V-24

5kW (17.000Btu)

18kW (80°C water)

-

24VDC

4A

Ø 225 mm

850 m³/h

Ø 180 mm

½”G O.D.

540 x 320 x 330

15,7 kg

€ 1.471,-

FC5 - 24

Ø 225 mm

850 m³/h

Ø 180 mm

Ø 16 mm

500 x 260 330

13,7 kg

€ 1.248,-

FC5 ELV

5kW (17.000Btu)

18kW (80°C water)

3kW

230VAC 50/60Hz

13,9A

Ø 225 mm

850 m³/h

Ø 180 mm

½”G O.D.

540 x 320 x 330

17,2 kg

€ 1.436,-

FC5

FC5 V

Ø 225 mm

850 m³/h

Ø 180 mm

½”G O.D.

540 x 320 x 330

15,7 kg

€ 1.351,-

FC5 ELV-24

5kW (17.000Btu)

18kW (80°C water)

3kW

24VDC

17A

Ø 225 mm

850 m³/h

Ø 180 mm

½”G O.D.

540 x 320 x 330

17,2 kg

€ 1.556,-

Fan coil units

27

Fan Coil Units 6kW

MARINE AIR-CONDITIONING, HEATING AND VENTILATION SYSTEMS

FC6

Cool capacity

Heat capacity

Elec. heat capacity

Voltage

Current

Type fan

Max. airflow

Airhose connection

Fluid connection

Dimensions (lxwxh)

Weight

Price

Cool capacity

Heat capacity

Elec. heat capacity

Voltage

Current

Type fan

Max. airflow

Airhose connection

Fluid connection

Dimensions (lxwxh)

Weight

Price

28

Fan coil units

FC6

6kW (20.400Btu)

20kW (80°C water)

-

230VAC 50/60Hz

1A

Ø 2 x 220 mm

2 x 650 m³/h

Ø 2 x 220mm

Ø 16 mm

680 x 200 x 320

13,5 kg

€ 1.354,-

FC6 V-24

6kW (20.400Btu)

20kW (80°C water)

-

24VDC

8,8A

Ø 2 x 220 mm

2 x 650 m³/h

Ø 2 x 150mm

½”G O.D.

720 x 250 x 320

15,5 kg

€ 1.817,-

FC6

FC6 - 24

6kW (20.400Btu)

20kW (80°C water)

-

24VDC

8,8A

Ø 2 x 220 mm

2 x 650 m³/h

Ø 2 x 220mm

Ø 16 mm

680 x 200 x 320

13,5 kg

€ 1.594,-

FC6 ELV

6kW (20.400Btu)

20kW (80°C water)

3kW

230VAC 50/60Hz

14A

Ø 2 x 220 mm

2 x 650 m³/h

Ø 2 x 150mm

½”G O.D.

720 x 250 x 320

18,5 kg

€ 1.747,-

FC6 V

6kW (20.400Btu)

20kW (80°C water)

-

230VAC 50/60Hz

1A

Ø 2 x 220 mm

2 x 650 m³/h

Ø 2 x 220mm

½”G O.D.

720 x 250 x 320

15,5 kg

€ 1.579,-

FC6 ELV-24

6kW (20.400Btu)

20kW (80°C water)

3kW

24VDC

21,8A

Ø 2 x 220 mm

2 x 650 m³/h

Ø 2 x 150mm

½”G O.D.

720 x 250 x 320

18,5 kg

€ 1.987,-

Fan Coil Units 7kW

MARINE AIR-CONDITIONING, HEATING AND VENTILATION SYSTEMS

FC7

Cool capacity

Heat capacity

Elec. heat capacity

Voltage

Current

Type fan

Max. airflow

Airhose connection

Fluid connection

Dimensions (lxwxh)

Weight

Price

Cool capacity

Heat capacity

Elec. heat capacity

Voltage

Current

Type fan

Max. airflow

Airhose connection

Fluid connection

Dimensions (lxwxh)

Weight

Price

FC7

7kW (23.800Btu)

22kW (80°C water)

-

230VAC 50/60Hz

1A

Ø 2 x 220 mm

2 x 650 m³/h

Ø 2 x 150mm

Ø 16 mm

790 x 200 x 325

15,8 kg

€ 1.520,-

FC7 V-24

7kW (23.800Btu)

22kW (80°C water)

-

24VDC

8,8A

Ø 2 x 220 mm

2 x 650 m³/h

Ø 2 x 150mm

½”G O.D.

830 x 250 x 325

17,8 kg

€ 1.983,-

FC7

FC7 - 24

7kW (23.800Btu)

22kW (80°C water)

-

24VDC

8,8A

Ø 2 x 220 mm

2 x 650 m³/h

Ø 2 x 150mm

Ø 16 mm

790 x 200 x 325

15,8 kg

€ 1.760,-

FC7 ELV

7kW (23.800Btu)

22kW (80°C water)

3kW

230VAC 50/60Hz

14A

Ø 2 x 220 mm

2 x 650 m³/h

Ø 2 x 150mm

½”G O.D.

830 x 250 x 325

20,8 kg

€ 1.685,-

FC7 V

7kW (23.800Btu)

22kW (80°C water)

-

230VAC 50/60Hz

1A

Ø 2 x 220 mm

2 x 650 m³/h

Ø 2 x 150mm

½”G O.D.

830 x 250 x 325

17,8 kg

€ 1.743,-

FC7 ELV-24

7kW (23.800Btu)

22kW (80°C water)

3kW

24VDC

21,8A

Ø 2 x 220 mm

2 x 650 m³/h

Ø 2 x 150mm

½”G O.D.

830 x 250 x 325

20,8 kg

€ 2.153,-

Fan coil units

29

Fan Coil Units 8kW

MARINE AIR-CONDITIONING, HEATING AND VENTILATION SYSTEMS

FC8

Cool capacity

Heat capacity

Elec. heat capacity

Voltage

Current

Type fan

Max. airflow

Airhose connection

Fluid connection

Dimensions (lxwxh)

Weight

Price

Cool capacity

Heat capacity

Elec. heat capacity

Voltage

Current

Type fan

Max. airflow

Airhose connection

Fluid connection

Dimensions (lxwxh)

Weight

Price

FC8

8kW (27.200Btu)

25kW (80°C water)

-

230VAC 50/60Hz

1A

Ø 250 mm

1000 m³/h

Ø 180mm

Ø 16 mm

525 x 255 x 380

15 kg

€ 1,628,-

FC8 V-24

8kW (27.200Btu)

25kW (80°C water)

-

24VDC

3,6A

Ø 250 mm

1000 m³/h

Ø 180 mm

½”G O.D.

565 x 300 x 380

17 kg

€ 2.203,-

30

Fan coil units

FC8 ELV

FC8 - 24

8kW (27.200Btu)

25kW (80°C water)

-

24VDC

3,6A

Ø 250 mm

1000 m³/h

Ø 180mm

Ø 16 mm

525 x 255 x 380

15 kg

€ 1.748,-

FC8 ELV

8kW (27.200Btu)

25kW (80°C water)

4kW

230VAC 50/60Hz

18A

Ø 250 mm

1000 m³/h

Ø 180 mm

½”G O.D.

565 x 300 x 380

18,5 kg

€ 2.185,-

FC8 V

8kW (27.200Btu)

25kW (80°C water)

-

230VAC 50/60Hz

1A

Ø 250 mm

1000 m³/h

Ø 180mm

½”G O.D.

565 x 300 x 380

17 kg

€ 1.745,-

FC8 ELV-24

8kW (27.200Btu)

25kW (80°C water)

4kW

24VDC

20,6A

Ø 250 mm

1000 m³/h

Ø 180 mm

½”G O.D.

565 x 300 x 380

18,5 kg

€ 2.305,-

Fan Coil Units 10kW

MARINE AIR-CONDITIONING, HEATING AND VENTILATION SYSTEMS

FC10 ELV

FC10 ELV

Cool capacity

Heat capacity

Elec. heat capacity

Voltage

Current

Type fan

Max. airflow

Airhose connection

Fluid connection

Dimensions (lxwxh)

Weight

Price

Cool capacity

Heat capacity

Elec. heat capacity

Voltage

Current

Type fan

Max. airflow

Airhose connection

Fluid connection

Dimensions (lxwxh)

Weight

Price

FC10

10kW (34.000Btu)

28kW (80°C water)

-

230VAC 50/60Hz

1A

Ø 280 mm

1100 m³/h

Ø 200 mm

Ø 16 mm

605 x 280 x 400

20 kg

€ 2.110,-

FC10 V-24

10kW (34.000Btu)

28kW (80°C water)

-

24VDC

2,3A

Ø 280 mm

1100 m³/h

Ø 200 mm

½”G O.D.

650 x 320 x 400

22 kg

€ 2.455,-

FC10 - 24

10kW (34.000Btu)

28kW (80°C water)

-

24VDC

2,3A

Ø 280 mm

1100 m³/h

Ø 200 mm

Ø 16 mm

605 x 280 x 400

20 kg

€ 2.230,-

FC10 ELV

10kW (34.000Btu)

28kW (80°C water)

4kW

230VAC 50/60Hz

18A

Ø 280 mm

1100 m³/h

Ø 200 mm

½”G O.D.

650 x 320 x 400

23,5 kg

€ 2.418,-

FC10 V

10kW (34.000Btu)

28kW (80°C water)

-

230VAC 50/60Hz

1A

Ø 280 mm

1100 m³/h

Ø 200 mm

½”G O.D.

650 x 320 x 400

22 kg

€ 2.333,-

FC10 ELV-24

10kW (34.000Btu)

28kW (80°C water)

4kW

24VDC

19,3A

Ø 280 mm

1100 m³/h

Ø 200 mm

½”G O.D.

650 x 320 x 400

23,5 kg

€ 2.538,-

Fan coil units

31

Fan Coil Units 13kW

MARINE AIR-CONDITIONING, HEATING AND VENTILATION SYSTEMS

FC13 ELV

Cool capacity

Heat capacity

Elec. heat capacity

Voltage

Current

Type fan

Max. airflow

Airhose connection

Fluid connection

Dimensioons (lxwxh)

Weight

Price

Cool capacity

Heat capacity

Elec. heat capacity

Voltage

Current

Type fan

Max. airflow

Airhose connection

Fluid connection

Dimensions (lxwxh)

Weight

Price

FC13

13kW (44.200Btu)

35kW (80°C water)

-

230VAC 50/60Hz

1,8A

Ø 2 x 225 mm

2 x 850 m³/h

2 x Ø 180 mm

Ø 16 mm

805 x 260 x 320

22,5 kg

€ 2.540,-

FC13 V-24

13kW (44.200Btu)

35kW (80°C water)

-

24VDC

8A

Ø 2 x 225 mm

2 x 850 m³/h

2 x Ø 180 mm

½”G O.D.

850 x 300 x 320

24,5 kg

€ 3.002,-

32

Fan coil units

FC13 - 24

13kW (44.200Btu)

35kW (80°C water)

-

24VDC

8A

Ø 2 x 225 mm

2 x 850 m³/h

2 x Ø 180 mm

Ø 16 mm

805 x 260 x 320

22,5 kg

€ 2.780,-

FC13 ELV

13kW (44.200Btu)

35kW (80°C water)

6kW

230VAC 50/60Hz

27,8A

Ø 2 x 225 mm

2 x 850 m³/h

2 x Ø 180 mm

½”G O.D.

850 x 300 x 320

27,5 kg

€ 2.933,-

FC13 ELV

FC13 V

13kW (44.200Btu)

35kW (80°C water)

-

230VAC 50/60Hz

1,8A

Ø 2 x 225 mm

2 x 850 m³/h

2 x Ø 180 mm

½”G O.D.

850 x 300 x 320

24,5 kg

€ 2.763,-

FC13 ELV-24

13kW (44.200Btu)

35kW (80°C water)

6kW

24VDC

34A

Ø 2 x 225 mm

2 x 850 m³/h

2 x Ø 180 mm

½”G O.D.

850 x 300 x 320

27,5 kg

€ 3.173,-

MARINE AIR-CONDITIONING, HEATING AND VENTILATION SYSTEMS

Defroster Units

For safety reasons it is important that the windows in the wheelhouse are clean. To solve that problem, a series of defroster units has been developed and added to the assortment of

Mar-ix.

Just warming up the air to demist the windows, generally gives poor results, especially when the humidity in the wheelhouse is high because of rainy weather.

The defroster units are equipped with a dual heat exchanger which warms up the air first and cools and dehumidifies the air. This decreases the humidity which cleans the windows faster and better.

With the special developped control panel, the temperature and airflow can be set stepless.

With the ‘dry air mode’ activated, the defroster unit will dehumidify the air.

Depending on the available space, the defroster unit can be placed behind the ceiling, to blow the air on the windows from above or the unit can be placed in the stearing console, to blow the air on the windows from below.

We are pleased to advise you about the possibilities of the system.

DF2x2 - 24

DF4LP - 24

Cool capacity

Heat capacity

Elec. Heat capacity

Voltage

Current

Type fan

Max. airflow

Airhose connection

Fluid connection

Dimensions (lxwxh)

Weight

Price

DF2x2 - 24

4kW (13.600Btu)

12kW (80°C water)

-

24VDC

5A

Ø 2 x 140 mm

2 x 300 m³/h

2 x Ø 100 mm

2 x ½”G O.D.

793 x 289 x 170

14,3 kg

€ 2.642,-

Control panel

DF4LP - 24

4kW (13.600Btu)

15kW (80°C water)

-

24VDC

4A

Ø 225 mm

750 m³/h

Ø 180 mm

½”G O.D.

216 x 616 x 772

22 kg

€ 2.953,-

Defroster units

33

MARINE AIR-CONDITIONING, HEATING AND VENTILATION SYSTEMS

Air Handling Units

New in the assortment of Mar-ix are the air handling units.

A serie, especially designed for marine application, produced with sustainable materials and a high quality finish.

Air handling units are applied to provide the ship with fresh, conditioned air.

The systems are avalaible in a large variety of configurations. For almost every ship we can supply a suitable system.

Mar-ix provides the unique possibility to apply a system with heat recovery. By placing a supply and return unit the energy in the used air can be recovered and added to the fresh air.

In this way a energy saving from 40% till 60% will be achieved. The total required energy to heat and cool the air will be decreased.

We can advise you with a full calculation to select a suitable system.

Fam 1-10

Fam 6-10

Fan

Filter

34

Air handling units

Type

Max. airflow

Voltage

Current

Airhose connection

1

2

Heat recovery

Ram 1

Fam

Ø 140 EC

– 250 EC

250 - 1600m³/h

24VDC / 220-230VAC 50-60Hz

0,5A - 3A

In Ø125

– 300 / Uit Ø100 - 180

HAF

F9

40-60%

Ram

Ø 140 EC

– 250 EC

250 - 1600m³/h

24 VDC / 220-230VAC 50-60Hz

0,5A

– 3A

In Ø125

– 300 / Uit Ø100 - 180

HAF

40-60%

MARINE AIR-CONDITIONING, HEATING AND VENTILATION SYSTEMS

Air inlet

Conditioned air

Air outlet

H ea t re co ve ry

Return air

FAM

Posibilities:

F ilt e r

F

-

H

R

+

H e a t re co ve ry

C o o lin g

-

M

+

H e a tin g

M

+

M

-

C o o lin g

/ h e a tin g

E le ct ri ca l h e a tin g

F a n

EH

RAM:

H

R

-

+

Air handling units

35

MARINE AIR-CONDITIONING, HEATING AND VENTILATION SYSTEMS

Electric Water Heaters

The Mar-ix electric heater gives the posibility to heat the fluid circuit of the heating system in a ship by electric power.

Unlike a diesel heater or a reverse cycle chiller unit, an electric heating unit is completely silent.

The desired temperature can be preset and the capacity can be controlled in two ways.

In the standard version, the temperature is limited and controlled by an internal thermostat.

If the liquid temperature is reaching the setpoint the heater will switch off, when the temperature has dropped to the preset level, the heater will switch on automatically.

As an option it is possible to expand the electric heater with an inverter system.

With this option, the output power of the heater will be automatically adjusted to the required capacity.

This achieves a constant heating capacity, resulting in a constant temperature of the liquid and equall loading of the electrical installation.

This reliable electric heater can also be used for frost protection of the ship.

The exceptional reliability is ensured because each individual electric heater is equiped with multiple elements. Failure of a single element will not affect the operation of the other elements.

HE3 HE15

Heat capacity

Voltage

Current

Water temperature

Fluid connection

Dimensions (lxwxh)

Weight

Price

HE3

3kW

230VAC of 400VAC

13A/230V of 4.5A/400V

30-90°C

2 x ¾’G O.T.

221 x 141 x 485

4 kg

€ 352,-

36

Accessories

HE7.5

7.5kW

400VAC

11A/400V

30-90°C

2 x ¾’G O.T.

221 x 141 x 937

7 kg

€ 1.270,-

HE15

15kW

400VAC

22A/400V

30-90°C

2 x ¾’G O.T.

221 x 141 x 937

7 kg

€ 1.686,-

MARINE AIR-CONDITIONING, HEATING AND VENTILATION SYSTEMS

Heat exchangers

Mar-ix supplies heat exchangers in various capacities and designs. These are applicable to various fluid systems, for separating technical and/or heat transfer wherever desired.

These heat exchangers are often applied to use the heat from the engines and/or generators, for heating up the vessel and the drinking water.

Pumps

Circulatiepompen

Max. waterflow

Circulatiepompen

Max. capacity

Max. current

RS15/7

2,5 m³ p/u

230VAC

125W

0,55A

TOP S30-7

6,8 m³ p/u

230VAC

195W

0,95A

BPHE2x7.5

TOP S30-10

10,6 m³ p/u

230VAC

400W

1,95A

BPHE2x15

BAC40-129

18 m³ p/u

230VAC

750W

2,1A

RS15/7 Top S30-7 Top S30-10 BAC40-129

Zeewaterpompen

Max. waterflow

Voltage

Max. capacity

Max. current

Electrical ball valve

MP20R

MP20R

1,6 m³ p/u

24VDC

45W

0,2A

SP108

SP-108

4 m³ p/u

230VAC

250W

1,2A

SP208

SP-208

8 m³ p/u

230VAC

400W

2A

Motor

230VAC

24VAC/DC

24VAC/DC

On/off

On/off

Modulair

Ball valve DN20 – ¾”G I.D.

DN25 - 1"G I.D.

2-way

DN32 – 1¼”G I.D.

3-way

DN40 – 1½”G I.D.

Accessories

37

Air hoses

MARINE AIR-CONDITIONING, HEATING AND VENTILATION SYSTEMS

Thermostaten

Type

Inner diameter

Outside diameter

Length

Price

L100

Ø 100 mm

Ø 120 mm

3 m

€ 48,20

L125

Ø 125 mm

L150

Ø 150 mm

Ø 145 mm Ø 170 mm

3 m

€ 57,20

3 m

€ 65,30

L180

Ø 180 mm

L200

Ø 200 mm

Ø 200 mm Ø 220 mm

3 m

€ 71,60

3 m

€ 74,10

Type

Afmetingen (wxhxd)

Build in depth

DIGITH

120 x 90 x 30 mm

20 mm

Standard supply

- thermostat

- manual

- speed control

- cables

Grills

Air supply grill Air return grill

Dimensions AxB

200 x 150 mm

250 x 150 mm

300 x 150 mm

Teak

€ 51,30

€ 58,10

€ 65,60

Cherry

€ 40,00

€ 46,30

€ 52,50

Mahogany

€ 34,40

€ 40,60

€ 45,60

Red Oak

€ 26,30

€ 30,60

€ 35,00

Walnut

€ 28,10

€ 32,50

€ 37,50

Dimensions AxB

200 x 200 mm

250 x 250 mm

300 x 300 mm

Teak

€ 41,30

€ 51,90

€ 63,80

Cherry

€ 33,10

€ 42,50

€ 51,90

Mahogany

€ 28,80

€ 36,90

€ 46,30

Red Oak

€ 22,50

€ 28,80

€ 36,30

Walnut

€ 23,10

€ 30,00

€ 38,10

38

Accessories

MARINE AIR-CONDITIONING, HEATING AND VENTILATION SYSTEMS

CONTENTS SYSTEM POSSIBILITIES

Clima chiller units

To cool and heat up with FC units

(Only for the Clima systems C5, C10 and C15 or the A5, A10 and A15 in combination with an external heater.)

To cool and heat up with FC units including boiler function

(Only for the Clima inverter systems CIV series.)

To cool with FC units and heat up with radiators

(Only for the Clima systems C5, C10 and C15 or the A5, A10 and A15 in combination with an external heater.)

To cool with FC units and heat up with FC units and radiators

(Only for the Clima systems C5, C10 and C15 or the A5, A10 and A15 in combination with an external heater.)

To cool with FC units and heat up with radiators including boiler function

(Only for the Clima inverter systems CIV series.)

To cool with FC units and heat up with FC units and radiators including boiler function

(Only for the Clima inverter systems CIV series.)

40

41

42

43

44

45

System possibilities

39

40

MARINE AIR-CONDITIONING, HEATING AND VENTILATION SYSTEMS

Flow circuit during cooling

Airco

M

12v

Heater

To cool and heat up with FC units

Circulation pump

Non-return valve

Non-return valve

Fan coil unit

Fan coil unit

Fan coil unit

Flow circuit during heating

Airco

M

12v

Heater

Circulation pump

Non-return valve

Non-return valve

Fan coil unit

Fan coil unit

Fan coil unit

Only for the Clima systems C5, C10 and C15 or the A5, A10 and A15 in combination with an external heater.

MARINE AIR-CONDITIONING, HEATING AND VENTILATION SYSTEMS

Flow circuit during heating and boiler in use

Cooling circuit main engine/generator

Heat function will automatically be supplied by the main engine or generator if this is in use.

To cool and heat up with FC units including boiler function

Circulation pump

Airco

Non-return valve

M

12v

Heater

Fan coil unit

Fan coil unit

Boiler

Circulation pump

Airco

M

12v

Heater

Non-return valve

Fan coil unit

Fan coil unit

Flow circuit during cooling

Cooling circuit main engine/generator

Boiler

Fan coil unit

Fan coil unit

Circulation pump

Airco

M

12v

Flow circuit with boiler in use

Cooling circuit main engine/generator

Heat function will automatically be supplied by the main engine or generator if this is in use.

Heater

Boiler

Non-return valve

Airco

M

12v

Flow circuit during cooling and boiler in use

Cooling circuit main engine/generator

Heat function will automatically be supplied by the main engine or generator if this is in use.

Heater

Boiler

Only for the Clima inverter systems CIV series.

Circulation pump

Non-return valve

Fan coil unit

Fan coil unit

Fan coil unit

Fan coil unit

Fan coil unit

Fan coil unit

41

42

MARINE AIR-CONDITIONING, HEATING AND VENTILATION SYSTEMS

Flow circuit during cooling

Airco

M

12v

Heater

To cool with FC units and heat up with radiators

Non-return valve

Circulation pump

Non-return valve

Fan coil unit

Fan coil unit

Fan coil unit

Thermostat valve

Radiator

Thermostat valve

Radiator

Thermostat valve

Radiator

Flow circuit during heating

Airco

M

12v

Heater

Non-return valve

Circulation pump

Non-return valve

Fan coil unit

Fan coil unit

Fan coil unit

Thermostat valve

Radiator

Thermostat valve

Radiator

Thermostat valve

Radiator

Only for the Clima systems C5, C10 and C15 or the A5, A10 and A15 in combination with an external heater.

MARINE AIR-CONDITIONING, HEATING AND VENTILATION SYSTEMS

To cool with FC units and heat up with FC units and radiators

Flow circuit during cooling

Airco

M

12v

Heater

Non-return valve

Circulation pump

Non-return valve

Fan coil unit

Fan coil unit

Fan coil unit

Thermostat valve

Radiator

Thermostat valve

Radiator

Thermostat valve

Radiator

Flow circuit during heating

Airco

M

12v

Heater

Non-return valve

Non-return valve

Circulation pump

Fan coil unit

Thermostat valve

Radiator

Fan coil unit

Thermostat valve

Radiator

Fan coil unit

Thermostat valve

Radiator

Only for the Clima systems C5, C10 and C15 or the A5, A10 and A15 in combination with an external heater.

43

MARINE AIR-CONDITIONING, HEATING AND VENTILATION SYSTEMS

To cool with FC units and heat up with radiators including boiler function

Non-return valve

Circulation pump

Airco

M

12v

Heater

Fan coil unit

Fan coil unit

Fan coil unit

Flow circuit during cooling

Cooling circuit main engine/generator

Boiler

Thermostat valve

Radiator

Thermostat valve

Radiator

Thermostat valve

Radiator

Non-return valve

Circulation pump

Airco

M

12v

Flow circuit during heating and boiler in use

Cooling circuit main engine/generator

Heater

Heat function will automatically be supplied by the main engine or generator if this is in use.

Boiler

Thermostat valve

Radiator

Fan coil unit

Fan coil unit

Thermostat valve

Radiator

Fan coil unit

Thermostat valve

Radiator

Non-return valve

Circulation pump

Airco

M

12v

Flow circuit with boiler in use

Cooling circuit main engine/generator

Heat function will automatically be supplied by the main engine or generator if this is in use.

Heater

Boiler

Thermostat valve

Radiator

Fan coil unit

Fan coil unit

Thermostat valve

Radiator

Fan coil unit

Thermostat valve

Radiator

44

Non-return valve

Circulation pump

Airco

M

12v

Flow circuit during cooling and boiler in use

Cooling circuit main engine/generator

Heat function will automatically be supplied by the main engine or generator if this is in use.

Heater

Boiler

Only for the Clima inverter systems CIV series.

Thermostat valve

Radiator

Fan coil unit

Fan coil unit

Thermostat valve

Radiator

Fan coil unit

Thermostat valve

Radiator

MARINE AIR-CONDITIONING, HEATING AND VENTILATION SYSTEMS

To cool with FC units and heat up with FC units and radiators including boiler function

Non-return valve

Circulation pump

Airco

M

12v

Heater

Fan coil unit

Fan coil unit

Fan coil unit

Flow circuit during cooling

Cooling circuit main engine/generator

Boiler

Thermostat valve

Radiator

Thermostat valve

Radiator

Thermostat valve

Radiator

Non-return valve

Circulation pump

Airco

M

12v

Flow circuit during heating and boiler in use

Cooling circuit main engine/generator

Heater

Heat function will automatically be supplied by the main engine or generator if this is in use.

Boiler

Thermostat valve

Radiator

Fan coil unit

Fan coil unit

Thermostat valve

Radiator

Fan coil unit

Thermostat valve

Radiator

Non-return valve

Circulation pump

Airco

M

12v

Flow circuit with boiler in use

Cooling circuit main engine/generator

Heat function will automatically be supplied by the main engine or generator if this is in use.

Heater

Boiler

Thermostat valve

Radiator

Fan coil unit

Fan coil unit

Thermostat valve

Radiator

Fan coil unit

Thermostat valve

Radiator

Non-return valve

Circulation pump

Airco

M

12v

Flow circuit during cooling and boiler in use

Cooling circuit main engine/generator

Heat function will automatically be supplied by the main engine or generator if this is in use.

Heater

Boiler

Only for the Clima inverter systems CIV series.

Thermostat valve

Radiator

Fan coil unit

Fan coil unit

Thermostat valve

Radiator

Fan coil unit

Thermostat valve

Radiator

45

MARINE AIR-CONDITIONING, HEATING AND VENTILATION SYSTEMS

Air supply grill

Digital thermostat

Isolated air hose

Skin fitting

Self contained unit

Sea water pump

Sea water strainer

Ball valve

Air return grill

Skin fitting

46

Example composition self contained unit installation.

Example composition self contained unit installation.

F a n

c o il tu b in g

1

6 m m

I

.D

.

m m

5 g b u e

H d a

Example composition airco chiller unit installation.

47

F a n

c il o tu b in g

1

6 m m

I

.D

.

m

5 m g b u d a e

H

48

Example composition clima chiller unit installation.

a

F n

c o il tu b in g

1

6 m m

I

.D

.

m m

H

Example composition airco inverter chiller unit installation.

49

a

F n

c o il tu b in g

1

6 m m

I

.D

.

m m

H

50

Example composition clima inverter chiller unit installation.

F a

c n o il tu b in

1 g

6 m m

I

.D

.

m m

5

2 g b u d a e

H

Example composition hydraulic driven chiller unit installation.

51

F a

c n il o tu b in

1 g

6 m m

I

.D

.

m m

H

52

Example composition reversed cycle chiller unit installation.

MARINE AIR-CONDITIONING, HEATING AND VENTILATION SYSTEMS

53

MARINE AIR-CONDITIONING, HEATING AND VENTILATION SYSTEMS

Mentioned prices are in euro’s excluding V.A.T. and valid until 31 December 2012.

Prices, specifications and images are with reservations of compose, printer’s and type errors.

We continuously aspire improvement of our products, as a result, interim modifications may be altered without possible notice.

Terms and conditions as per our conditions of sale (available on request).

All our systems come with 3 years full warranty!

54

APPLICATION FORM

NAME

CONTACTPER

ADDRESS

POST CODE

PLACE

Project

Type of boat

Dimensions (lxw)

Use

System

Climate

Approval

Pleasure / Profession

Cooling / Cooling-heating

Normal / Tropical

05.

06.

07.

01.

02.

03.

04.

08.

09.

10.

Notes:

Name area

MARINE AIR-CONDITIONING, HEATING AND VENTILATION SYSTEMS

Place

COUNTRY

TELEPHONE

FAX

EMAIL

CUSTOMER CODE

Voltage

Brand generator

Type generator

Generator capacity

Generator voltage

Number of area’s

12v / 24v

Length (m) Width (m) Hight (m)

Application form

55

MARINE AIR-CONDITIONING, HEATING AND VENTILATION SYSTEMS

EXPLANATION FOR REQUEST FORMULAR

Project

Your reference.

Type of boat (motor / sailboat) / Dimensions (lxw)

The type of boat gives us, together with the outside dimensions an impression of the possibillities for our systems.

Use (pleasure / profession)

With this information we can choose a system that demands your needs, and at the same time will be as economical as possible. Every situation can be different. Do you wish cooling in all spaces at the same time or just in the saloon during the day and in the bedrooms at night? This information will decide the total capacity/size of the system.

System (cooling / cooling-heating)

For just cooling our self contained and airco chiller units will be all you need. When a cooling and heating system will be needed in warmer climates, than our reversed cycle chiller units will satisfy. The outside water temperature must stay above 5 to 7 °C for functioning. For climates like the Northern of Europe or other cold climates during the winter our clima chiller systems will be satisfy. For heating these systems are provided with an Eberspächer diesel heater. It is also possible to connect a excisting heating system onto our systems for an integral adjustment of the digital thermostat. Also existing radiators can be connected.

Place

Herewith we calculate an average of capacity: upper deck/ centre deck/ lower deck. Tothether with the choice of climate we can decide the needed capacity. An upper deck cabin with a lot of windows will ask more cooling capacity than a lower deck sleeping room.

Climate

To decide the needed capacity a cooling calculation will have to be made. The choice of climate (normal/tropical) together with the place (upper/mid or lower deck) will give us a calculation figure.

Approval

When your situation subscribes an approved system we can take care of this.

Battery/generator details

All our systems will need a 12 or 24v-dc connection for memory and control. The 230/400v-ac 50/60Hz connection to supply the compressors and pumps. Most of the generators are suitable for this power. If you do not have these details please give us the brand and type of the generator.

Name area

Your defenition of the space as: saloon, sleeping room 1 /2 etc.

56

Explanation for request formular

MAR-IX IS A PRODUCT FROM MAVÉ B.V. WWW.MAVE.NL

NAUTIC & INDUSTRIAL ENGINEERING

Mavé B.V.

Lisdoddeweg 21

8251 SM DRONTEN

The Netherlands

Tel. +31(0)321-337467

Fax +31(0)321-337542

Web: www.mave.nl

Email: [email protected]

advertisement

Related manuals

advertisement