VistaMAX Starter Kits

VistaMAX Starter Kits
VistaMAX Starter Kits
The 3.5 GHz VistaMAX Starter Kit by Vecima Networks is designed to enable operators to assess the
performance and capabilities of the WiMAX standard in general and of Vecima Networks’ VistaMAX product
family. VistaMAX is ideal for providing last mile access or for offering broadband connectivity. The starter kits
include all the cabling and peripheral equipment necessary for the operator to deploy.
Designed and manufactured by Vecima Networks, the VistaMAX is based on the IEEE 802.16-2004 standard
and currently operates in frequencies between 3300 and 3800 MHz. Both the VistaMAX base and subscriber
stations are contained in a weatherproof sealed housing. The base station has an integrated 60, 90 or 120
degree antennas to offer a single box solution for WiMAX applications. External antennas can be
accommodated with an optional N female connector. VistaMAX is a state of the art solution that can be deployed
rapidly and is suitable for temporary or permanent installations where high speed data, voice or video services
are required.
•
•
•
•
•
•
•
Up to 21.7 Mbps
Time Division Duplexing (TDD)
Software selectable channel bandwidths of 1.75, 3.5 and 7 MHz
Integrated GPS synchronization
True non line-of-sight performance
Fast adaptive modulation (BPSK, QPSK, 16QAM or 64QAM) for both uplink and downlink
Power over Ethernet for convenient single cable connections
OBR3500 (Outdoor Base Station)
OSR3500 (Outdoor Subscriber Station)
NMS8000 / SSP (Management Server)
Training and installation
Price
3
Platinum
4
12
1
3 day1
Gold
1
5
1
Onsite2
Silver
1
5
1
3 day
Bronze
1
5
1
-
Basic
1
5
3 day
$33,999
$18,499
$14,499
$12,499
$10,499
1
3 day VistaMAX training for 4 people at Vecima’s Saskatoon facilities.
3 day training provided by Vecima engineer at your location, some exceptions apply.
3
All pricing is in US$ and is subject to change. Please request a current quote prior to ordering.
2
vistamax_sk_wp_03.pdf
Page 2
VistaMAX Starter Kits
OBR3500
OSR3500
RF
RF Frequency
3300 to 3400 MHz
3400 to 3650 MHz
3600 to 3800 MHz
+45 dBm EIRP (60o integrated antenna)
+43 dBm EIRP (90o integrated antenna)
+42 dBm EIRP (120o integrated antenna)
+28 dBm at external antenna connector
Industry Canada RSS-192
ETSI EN 301 021 v1.6.1
3300 to 3800 MHz
10/100BaseT 802.3 Ethernet
1024
SNMP (WiMAX Forum MIBs + Vecima
Networks extensions)
Built in HTTPS web server
Telnet/SSH CLI
Syslog
10/100BaseT 802.3 Ethernet
Up to 63
SNMP (WiMAX Forum MIBs + Vecima
Networks extensions)
Built in HTTPS web server
Telnet/SSH CLI
Syslog
No. of Subscribers Supported
EMC/EMI
Lightning protection
Power Supply
1024
ETSI EN 301 489-1
Multi-strike protection built-in
36 to 56 VDC Power over Ethernet
Power Consumption
45 W maximum
ETSI EN 301 489-1
Built-in
Requires IEEE 802.3af-compliant
Power over Ethernet
12.5 W maximum
-45oC to +550C
20" x8" x5" (50.8cm x20cm x12.7cm)
Pole mount (2.5" to 4.5" diameter pole)
20 lbs. (9 Kg)
-
-45oC to +550C
12" x12" x3" (30.5cm x30.5cm x7.7cm)
Pole mount (1" to 1.75" diameter pole)
5 lbs. (2.3 Kg)
NEMA 4X/IP66
Maximum Rated Output Power
Spectral Mask Compliance
+38 dBm EIRP
Industry Canada RSS-192
ETSI EN 301 021 v1.6.1
Network
LAN Interface
Bridged MAC Addresses
Supported
Management/Monitoring Interfaces
Operational Parameters
Mechanical
Operating Temperature
Physical
Mounting
Weight
Weatherproofing
vistamax_sk_wp_03.pdf
Page 3
VistaMAX Starter Kits
Secure Web Interface Connection (HTTPS)
Different access levels for users (Customizable read/write for each NMS feature set)
Network Monitor
Up to date information per subscriber (Configurable update time for all IP and RF stats)
System alarm and warnings (Notifications from state changes of monitored devices)
Application server monitoring (ICMP, SMTP, POP3, and HTTP)
System Level Services
Define QoS service packages, service flows and classifiers
Add/Remove BS and registered SS
Configure as DHCP server
Set SNMP v2c strings
Monitor POP3, SMTP, ICMP, and HTTP services
Subscriber Monitor
Numerically and graphically displays RF parameters per SS
Graphical uplink and downlink SS byte usage per SS
Geographical Interface
Map available with all SS and BS locations
Reports
Online Change (1,2,7 day)
All users throughput (2 day 5 minute average)
Base station throughput
CPE-IP per SS (IP addresses of host devices)
DHCP lease report
All subscriber monthly byte usage
SS distance (Customer name, SS distance & bearing to BS)
Sectors
Operating
Current
(Amps)
Peak
Current
(Amps)
0
1
2
4
8
0.89
1.26
1.63
2.4
3.87
2.19
2.56
2.93
3.7
5.17
1
2
4
8
1.31
1.71
2.54
4.18
2.75
3.16
3.97
5.61
OBR3500 (3.5 GHz)
Peak
Operating
Power
Power (W)
(W)
42.72
105.12
60.48
122.88
78.24
140.64
115.2
177.6
185.76
248.16
OBR1900 (1.9 GHz)
62.88
132
82.08
151.68
121.92
190.56
200.64
269.28
*Total power includes NMS power of 400W at 48V and 8.3Amps
vistamax_sk_wp_03.pdf
Page 4
Total Operating
Power (W)*
Total Peak
Power (W)*
442.72
460.48
478.24
515.2
585.76
505.12
522.88
540.64
577.6
648.16
462.88
482.08
521.92
600.64
532
551.68
590.56
669.28