HM8112-3 6½-Digit Precision Multimeter HM8112-3 HM8112-3S: Multimeter with built-in Scanner Card (8+1 Channels, 2- and 4-Wire) R 6½-Digit Display (1,200,000 Counts) R Resolution: 100 nV, 100 pA, 100 µΩ, 0.01 °C/F R DC Basic Accuracy 0.003 % R 2-Wire/4-Wire Measurements R Measurement Intervals adjustable from 0.1…60 s HZ42 19“ Rackmount Kit 2RU R Up to 100 Measurements transmitted to PC per Second R True RMS Measurement, AC and DC+AC R M athematic Functions: Limit Testing, Minimum/Maximum, Average and Offset R T emperature Measurements with Platinum (PT100/PT1000) and Ni (K and J types) Sensors Precise Temperature Measurement with Sensor R Internal Data Logger for up to 32,000 Measurement Results R Offset Correction R G alvanically isolated USB/RS-232 Interface, optional IEEE-488 (GPIB) R Optional: Scanner Card (8+1 Channels each 2- and 4-Wire) Accuracy: Values given are in ±(% of reading. + % of full scale) 6½-Digit Precision Multimeter HM8112-3 All data valid at 23 °C after 30 minutes warm-up. DC specifications Ranges: Input impedance 0.1 V, 1.0 V: 10 V, 100 V, 600 V: Accuracy: Range 0,1 V 1,0 V 10,0 V 100,0 V 600,0 V 1 year; % rdg. 0,005 0,003 0,003 0,003 0,004 Integration time: Display range: 600 V range: Resolution: Zero point Temperature drift: Long-term stability: AC specifications Measurement ranges: Measurement method: 0.1 V; 1 V; 10 V; 100 V; 600 V >1 GΩ 10 MΩ Values given are in ±(% of reading (rdg.) + % of full scale (f.s.)) 23 °C ±2 °C % f.s. 0,0006 0,0006 0,0006 0,0006 0,0006 Temp. coefficient 10…21 °C + 25…40 °C 0,0008 0,0008 0,0008 0,0008 0,0008 0.1 s 120.000 digit 60.000 digit 1 µV 1…60 s 1,200.000 digit 600.000 digit 100 nV better than 0.3 µV/°C better than 3 µV for 90 days 0.1 V; 1 V; 10 V; 100 V; 600 V true rms DC or AC coupled (not in 0.1 V range) Input impedance: 1 GΩ II <60 pF 0.1 V, 1 V: 10 MΩ II <60 pF 10…600 V: 1.5 sec to within 0.1 % of reading Response time: For sine wave signals >5 % of full scale Accuracy: Values given are in ±(% of reading + % of full scale); 23 °C ±2 °C for 1 year Range 20 Hz…1 kHz 1…10 kHz 10…50 kHz 50…100 kHz 100…300 kHz 0.1 V 0.1+0.08 5+0.5 (5 kHz) 1.0 V 0.08+0.08 0.15+0.08 0.3+0.1 0.8+0.15 7+0.15 10.0 V 0.08+0.08 0.1+0.08 0.3+0.1 0.8+0.15 4+0.15 100.0 V 0.08+0.08 0.1+0.08 0.3+0.1 0.8+0.15 600.0 V 0.08+0.08 0.1+0.08 Temperature coefficient 10…21 °C and 25…40 °C; (% rdg. + % f.s.) 0.01 + 0.008 at 20 Hz…10 kHz: 0.08 + 0.01 at 10…100 kHz: 7:1 (max. 5x range) Crest factor: 0.1s 1…60s Integration time: 120.000 digit 1,200.000 digit Display range: 600.00 digit 600.000 digit 600 V range: 1 µV 100 nV Resolution: Overload protection: (V/Ω-HI to V/Ω-LO) and to chassis: all Measurement ranges: all the time 850 Vpeak or 600 Vdc Maximum input voltage LOW against 250 Vrms at max. 60 Hz or 250 Vdc chassis/safety earth: Current specifications Ranges: Integration time: Display ranges: 1 A range: Resolution: Accuracy: (1 year; 23 °C ±2 °C) Temperature coefficient/°C: (%rdg. + %f.s.) Voltage: Response time: Crest factor: Input protection: 100 µA; 1 mA; 10 mA; 100 mA; 1 A 0.1 s 1…60 s 120.000 digit 1,200.000 digit 100.000 digit 1,000.000 digit 1 nA 100pA DC 45 Hz…1 kHz 1…5 kHz 0.02 + 0.002 0.1 + 0.08 0.2 + 0.08 10…21 °C 25…40 °C 0.002+ 0.001 0.01+ 0.01 <600 mV…1.5 V 1.5 s to within 0.1 % of reading 7:1 (max. 5 x range) fuse, FF 1 A 250 V Resistance Ranges: Integration time: Display ranges: Resolution: 100 Ω, 1 kΩ, 10 kΩ, 100 kΩ, 1 MΩ, 10 MΩ 0.1 s 1…60 s 120.000 digit 1,200.000 digit 1 mΩ 100 µΩ Range 100 Ω 1 kΩ 10 kΩ 100 kΩ 1 MΩ 10 MΩ 1 year; %rdg 0.005 0.005 0.005 0.005 0.05 0.5 23 °C ±2 °C %f.s. 0.0015 0.001 0.001 0.001 0.002 0.02 Temp. coefficient/°C 10…21 °C 25…40 °C 0.0008 0.0008 0.0008 0.0008 0.0008 0.0008 0.0008 0.0008 0.002 0.002 0.01 0.01 Measurement current: Range 100 Ω, 1 kΩ 10 kΩ 100 kΩ 1 MΩ 10 MΩ max. measurement voltage: approx. 3 V 250 Vp Overload protection: Current 1 mA 100 µA 10 µA 1 µA 100 nA Temperature measurement 2- and 4-wire measurement PT100/PT1000 (EN60751): -200…+800 °C Range: 0.01 °C; measurement current 1 mA Resolution: ±(0.05 % rdg. + sensor tolerance + 0.08 K) Accuracy: Temperature coefficient 10…21 °C and 25…40 °C: <0.0018 °C/°C NiCr-Ni (K-type) -270…+1,372 °C Range: 0.1 °C Resolution: ±(0.7 % rdg. + 0.3 K) Accuracy: NiCr-Ni (J-type) -210…+1,200 °C Range: 0.1 °C Resolution: ±(0.7 % rdg. + 0.3 K) Accuracy: Frequency and period specifications 1 Hz…100 kHz Range: 0.00001…1 Hz Resolution: 0.05 % of reading Accuracy: 1…2 s Measurement time: Interface Interface: Functions: Inputs: Outputs: USB/RS-232 (HO820), IEEE-488 (option) Control/Data fetch Function, range, integration time, start command Measurement results, function, range, integration time (10 ms…60 s) Miscellaneous Time to change range or function approx. 125 ms with DC voltage, DC current, resistance approx. 1 s with AC voltage, AC current 30,000 readings /128 kB Memory: Safety class I (EN 61010) Safety class: 105…254 V~; 50/60 Hz, CAT II Power supply: approx. 8 W Power consumption: +5…+40 °C Operating temperature: -20…+70 °C Storage temperature: 5…80 % (non condensing) Rel. humidity: 285 x 75 x 365 mm Dimensions (W x H x D): approx. 3 kg Weight: Accessories supplied: Line cord, Operating manual, PVC test lead (HZ15), Interface cable (HZ14) Recommended accessories: HO112 Scanner Card (Installation only ex factory) as HM8112-3S HO880 IEEE-488 (GPIB) Interface (galvanically isolated) HZ10S 5 x Silicone test lead black HZ10R 5 x Silicone test lead red HZ10B 5 x Silicone test lead blue HZ13 Interface cable (USB) 1.8 m HZ33 Test cable 50 Ω, BNC/BNC, 0.5 m HZ34 Test cable 50 Ω, BNC/BNC, 1 m HZ42 19” Rackmount kit 2RU HZ72 GPIB-Cable 2 m HZ887 Temperature probe HM8112-3E/010611 · C&E · Subject to change without notice · © HAMEG Instruments GmbH® · DQS-certified in accordance with DIN EN ISO 9001:2008, Reg.-No.: 071040 QM08 HAMEG Instruments GmbH · Industriestr. 6 · D-63533 Mainhausen · Tel +49 (0) 6182 8000 · Fax +49 (0) 6182 800100 · www.hameg.com · [email protected]
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
advertisement