Thank you for purchasing this Samsung product.

Paper_AX034HPXAWQ_IB_EN_04615A-01.indd 33 2014-02-24 오전 10:23:29

Features of your air purifier with humidification function

TOTAL AIR CARE!! Purification, humidification, sterilization functions can operate with one appliance!!

As the functions of purification, humidification and sterilization are combined, this Samsung air purifier with humidification function enables you to use your living space efficiently.

The combination of the 3 step filter purification system pre filter (for large dust)  HEPA filter (for fine dust)  deodorization filter (for harmful gas and odor) and the sterilization function of S-Plasma ion will improve indoor air quality.

The fine water particles produced by natural humidification are easily absorbed into skin and spread far away to humidify the indoor room evenly. In addition, the appliance maintains a healthy humidity of 40%~60% to provide you with healthy living environment.

S-Plasma ion captures the harmful materials floating in the air through HOO – that is produced by combining active hydrogen (H) with oxygen ion(O

2

– ) and destroys the hydrogen bond of protein structure to perform sterilization which removes germ, virus, and mold in the air.

Samsung air purifier with humidification function uses a water purification filter to prevent white powder caused after moisture vaporizes from forming.

High-class design centric as it is easy to use and in harmony with any indoor interior.

Contents

Preparation

Safety precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

Check before use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10

Check the name of the components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14

Basic function

Operation mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16

Sleep mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17

S–Plasma ion . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17

Others

Cleaning and maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18

Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27

Paper_AX034HPXAWQ_IB_EN_04615A-01.indd 2

ENGLISH-2

2014-02-24 오전 10:23:07

PrEPArATION

Safety precautions

These safety precautions are for owner’s safety and preventions of property damage. Therefore, please read this manual thoroughly before using your air purifier.

WARNING

CAUTION

Hazards or unsafe practices that may result in severe

personal injury or death.

Hazards or unsafe practices that may result in minor

personal injury or property damage.

Follow directions.

Do NOT attempt.

Make sure the machine is grounded to prevent electric shock.

Unplug the appliance.

Do NOT disassemble.

FOR INSTALLATION WARNING

Plug the power cord into a wall socket with the power specifications of the product or higher and use the socket for this appliance only. In addition, do not use an extension cord.

power strip or extending the power cord may result in electric shock or fire.

or fire.

may cause electric shock or fire.

Paper_AX034HPXAWQ_IB_EN_04615A-01.indd 3

ENGLISH-3

2014-02-24 오전 10:23:07

Safety precautions

FOR INSTALLATION WARNING

Do not install this appliance near a heater, inflammable material.

Do not install this appliance in a humid, oily or dusty location, in a location exposed to direct sunlight and water (rain drops). Do not install this appliance in a location where gas may leak.

FOR INSTALLATION CAUTION

The appliance should be installed in a place where the power cord of the product can be easily pulled out.

leakage.

Install your appliance on a level and hard floor that can support its weight.

problems with the product.

There should be over 15cm space around the appliance.

decrease.

damaged.

When installing the appliance, be careful not to press the power cord.

Paper_AX034HPXAWQ_IB_EN_04615A-01.indd 4

ENGLISH-4

2014-02-24 오전 10:23:07

FOR POWER SUPPLY WARNING

Unplug the product, and then remove foreign substances

(dust, moisture, etc.) of the power plug terminal or power plug connection part with a dry cloth on a regular basis.

When the appliance or power plug or power cord is damaged, contact your nearest service center.

Plug the power plug into the wall socket firmly. Do not use a damaged power plug, damaged power cord or loose wall socket.

When unplugging the product, do not pull the power cord. Grip the power plug, and then pull the power plug.

Do not pull or excessively bend the power cord. Do not twist or tie the power cord.

Do not hook the power line over a metal object, place a heavy object on the power cord, insert the power line between objects, or push the power cord into the space behind the appliance.

FOR POWER SUPPLY CAUTION

When not using the air purifier for a long period of time or during a thunder or lightning storm, disconnect the power supply.

Paper_AX034HPXAWQ_IB_EN_04615A-01.indd 5

ENGLISH-5

2014-02-24 오전 10:23:07

Safety precautions

FOR OPERATION WARNING

If the appliance is flooded, turn off the appliance and contact a service center.

If the appliance generates a strange noise, a burning smell or smoke, disconnect the power supply immediately and contact a service center.

When gases (city gas, profane gas, etc.) leak, do not touch the power cord. Immediately ventilate the area and contact a service center or a qualified technician.

Do not unplug the appliance during operation.

may result in electric shock or fire.

When repairing is needed, contact a service center.

leakage, electric shock and fire.

Do not touch the power plug with wet hands.

Do not strike or pull the appliance with excessive force.

product.

After unpacking the air purifier, keep all packaging materials out of the reach of children.

Do not insert your fingers or foreign substances into the air inlet or air outlet. inserting their fingers into the appliance.

ENGLISH-6

Paper_AX034HPXAWQ_IB_EN_04615A-01.indd 6 2014-02-24 오전 10:23:07

Do not place an object near the outdoor unit that allows children to climb onto the machine.

Do not open the water bottle door during operation and do not put your hands into the outlet.

Do not put other foreign materials such as metal into the appliance.

If water has entered power supply part, unplug the appliance and dry it completely before use.

Do not shake or move the appliance while the appliance(water bottle and tray) contains water.

fire.

Do not use humidification detergent.

Do not place heavy things onto the appliance.

Do not attempt to repair, disassemble, or modify the appliance yourself.

the standard fuse. malfunction or injury.

If any foreign substance such as water has entered the appliance, disconnect the power supply and contact a service center.

Paper_AX034HPXAWQ_IB_EN_04615A-01.indd 7

ENGLISH-7

2014-02-24 오전 10:23:07

Safety precautions

FOR OPERATION CAUTION

Keep about 2m distance from other electric appliances such as

TV, video, audio etc.

Leave more than 15cm space between the product and the wall.

installing the appliance in the middle of the place might be efficient. However, when installing the appliance at wall side, allow more than 15cm between the appliance and the wall.

Do not spray volatile material such as insecticide onto the appliance.

shock, fire or product malfunctions.

Do not tilt or turn the appliance upside down, while the appliance is plugged in.

Do not use a damaged water bottle.

Do not put hot (over 40 °C) or polluted water (salinity, detergent, chemical etc) into the water bottle.

Do not install or operate the appliance at a place where the water in the appliance may be frozen.

malfunction.

humidification function is 16 °C~30 °C.

Do not put the appliance into the water.

ENGLISH-8

Paper_AX034HPXAWQ_IB_EN_04615A-01.indd 8 2014-02-24 오전 10:23:08

After removing the upper cover, do not press the switches on the upper left side of the product with hands and chopsticks.

Do not drink the water from the tray of the appliance.

Do not place the appliance on the edge of a desk and table.

Do not stand on top of the appliance or place objects (such as laundry, lighted candles, lighted cigarettes, dishes, chemicals, metal objects, etc.) on the appliance.

malfunction and injury.

Do not operate the appliance with wet hands.

Do not eat grains in the water purification filter.

This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.

Children should besupervised to ensure that they do not play with the appliance.

FOR CLEANING WARNING

Do not clean the appliance by spraying water directly onto it.

Do not use benzene, thinner, acetone or alcohol to clean the appliance.

electric shock or fire.

Disconnect the power supply and stop the fan operation before cleaning the appliance.

ENGLISH-9

Paper_AX034HPXAWQ_IB_EN_04615A-01.indd 9 2014-02-24 오전 10:23:08

Check before use

Checking installation

Check the required installation condition below.

Check the power plug and socket

(When the appliance is plugged in, it will be changed to operation waiting status.)

Product information

Clean the humidification filter and the tray and then operate the appliance again.

This is not foreign matter but fiber materials of the humidification filter. If the floating particles of dust are generated a lot, clean the tray and then operate the appliance again.

Temperature range for operation of air purifier with humidification function

Design information

Paper_AX034HPXAWQ_IB_EN_04615A-01.indd 10

ENGLISH-10

2014-02-24 오전 10:23:08

Displaying current humidity

Using a filter f ) is on, change the HEPA filter and the deodorization filter.

(The HEPA filter and deodorization filter removes invisible fine dust and gas or odor particle. Therefore, even though the filter looks fine, you should change those filters on a regular basis. As the filter exchange period is set based on maximum hours of usage by considering its operation hour, the exchange period might be different by indoor environment.) filter) should be changed.

maintain better indoor environment.

Product specification

Model

Product size(WxHxD)

Water bottle capacity

AX034HPXAWQ Series

450 mm X 478 mm X 274 mm

3.4 ℓ

❋ ❋ Design or product specification might be changed without notice for product improvement.

Paper_AX034HPXAWQ_IB_EN_04615A-01.indd 11

ENGLISH-11

2014-02-24 오전 10:23:08

Check before use

Water supply

Use tap water for the safe and long term use of your air purifier with humidification function.

1. While the air purifier with humidification function is switched off, detach the upper cover ( ①) and lift off (②) the water bottle.

2. Open the water bottle cap.

- Turn the bottle cap in an anticlockwise direction. Before opening the water bottle, press the port in the middle of the bottle cap, which will release the vacuum and make the bottle cap easier to open.

3. Filling water for the water bottle.

- Use tap water (which shouldn’t be hotter than 40 °C).

- When filling the bottle, you should grip the water bottle tightly.

Port

Upper cover

Water bottle

4. Close the water bottle cap.

- Turn the bottle cap in clockwise direction.

5. After putting the water bottle into the water bottle box( ①), attach the upper cover( ②).

Upper cover

Water bottle handle

Water bottle

Paper_AX034HPXAWQ_IB_EN_04615A-01.indd 12

ENGLISH-12

2014-02-24 오전 10:23:09

NOTE

• When the appliance runs out of water during operation, (water supply) light will flash.

• To start the humidification mode, allow about 1-5 minutes after filling the water bottle when the appliance is supplied with enough water, (water supply) light will go out and then return to the previous mode.

• Tap water reduces the bacterial growth of the water bottle and tray as the tap water contains chlorine. If the hardness of tap water is high, white powder (impurities) may be formed on a filter or tray. In this case, clean the appliance more frequently.

• When the water from reverse osmotic pressure water purifier is used, less white powder will be generated than using tap water. However, as the water of reverse osmotic pressure water purifier does not have chlorine there could be faster bacterial growth. Clean the water bottle or tray more frequently with a neutral detergent and using tap water is recommended. (reverse osmotic pressure method : Pressure larger than osmotic pressure is applied to the denser solution so that water can move to the light part for purification.)

• Hardness indicates the amount of calcium ion and magnesium ion in water. Limestone and shoreline area shows high hardness.

CAUTION

• If you assemble the water bottle incorrectly after supplying the water, this may result in water leakage.

Paper_AX034HPXAWQ_IB_EN_04615A-01.indd 13

ENGLISH-13

2014-02-24 오전 10:23:09

Check the name of the components

Air purifier with humidification function

Upper cover

Opens and closes the upper cover to check the water bottle or pre filter

Pre filter

Filters the dust of the incoming air

Dust sensor

Detects dust in the air

Button control part and display panel

HEPA/Deodorization filter

Safety net

S-Plasma ion

Tray rail

Puts or pulls the tray in and out of the air purifier with humidification function

Water bottle

Air outlet

Output of the humidity or air flow

Air intake

Sucks in the outdoor air

Water level indicator

Checks the amount of remaining water in the water bottle

Humidification hydraulic turbine

Side cover

Opens and closes to check the hydraulic turbine and tray

Tray

Stores the water flowing from water bottle

Water level adjustment

Adjusts the amount of water supply or water level

Opening the upper cover

Grip each side grooves on the back of the appliance and lift up the upper cover.

Opening the side cover

After pulling out the upper cover and the water bottle( ①), detach the side cover from the appliance by pulling the handle part at the right bottom of the appliance in the arrow direction( ②).

Paper_AX034HPXAWQ_IB_EN_04615A-01.indd 14

ENGLISH-14

2014-02-24 오전 10:23:11

Buttons on the control panel

Button control part

전원

풍량/모드

예약

가습

S-Plasma ion

Humidification mode display

Water supply display

Displays when water supply is needed

Current purification level display

Displays current air purification level

Fan speed/Auto/Sleep display

Displays fan speed adjustment or Auto/

Sleep mode

Current humidity or off timer display

Displays current humidity, desired humidity(%) or off time(Hr)

Filter exchange display

S-Plasma ion display

Displays S-Plasma ion function

Buttons on the control panel

Power button

Fan speed/Auto/Sleep button

Off timer button

Humidification mode or desired humidity adjustment button

S-Plasma ion button

Filter exchange icon off button

Turns the air purifier with humidification function on or off.

Adjusts fan speed or selects Auto or sleep mode.

Set the off time for the air purifier with humidification function.

Adjusts humidification mode or desired humidity.

Turn the S-Plasma ion(sterilization) function on or off.

resets the filter exchange display function after filter exchange.

NOTE

• When pressing the [ ]button on the control panel, the appliance starts and set mode and function will be displayed.

• When pressing a button and then the selected function is displayed with sound, it indicates that the function has been set.

Purification display

• Displays the purification level by odor or dust sensor.

• Purification display description

• red : Low(Polluted) / Orange : Medium(Normal) / Blue : High(Purity)

ENGLISH-15

Paper_AX034HPXAWQ_IB_EN_04615A-01.indd 15 2014-02-24 오전 10:23:12

BASIC FUNCTION

Operation mode

You can select humidification and purification mode or purification mode only.

Humidification and purification mode time. f ] light will be on on the control panel and the desired humidity can be adjusted.

Purification mode f ] light on the control panel will go out and desired humidity cannot be adjusted.

NOTE

• When the humidification function is not in use, detaching the hydraulic turbine before using the appliance is recommended. (refer to p.10)

• When you only use the purification mode without using the humidification function, get rid of all the water within the tray and the water bottle, wash the humidification filter, and make sure to dry them all before using the product.

• Unpleasant smell may occur if the humidification hydraulic turbine is not being used while it is wet. Keep the humidification hydraulic turbine after cleaning it thoroughly. (refer to page 20.)

1. Press [ ] button to start the humidification and purification mode.

- The air purifier with humidification function will be turned on with sound.

- When plugging the appliance in and turning it on, it will start as humidification and purification mode(Fan speed: [ ](Low)).

- When turning the appliance on again, the mode you set before turning the appliance off will remain.

- When the fan speed is auto, desired humidity cannot be adjusted.

2. Press [ ] button to adjust the desired humidity in humidification and purification mode.

- When pressing the button once time, current humidity will be displayed and each time you press the button, the desired humidity will be increased by 5%. You can set the humidity range from 30 to 70%.

- You can select either humidification and purification mode or purification mode only by adjusting humidity level. When the desired humidity is 70%, press [ ] button one more time to turn off the [ ] light and to stop the humidification mode and to start the purification mode.

- When the fan speed is Auto, the proper humidification and purification status will be maintained depending on the ambient temperature, humidity, dust, and odor.

- When the [ ] light is not lit up, the humidification function does not operate.

- If the [ ] icon blinks during humidification and purification mode, the mode will be stopped.

3. Press [ ] button to adjust fan speed.

- (Low)  (Medium)  rotation.

(Strong)  Auto  (Sleep) will be selected in

- When the fan speed is Auto, the proper humidification and purification status will be maintained depending on the ambient temperature, humidity, dust, and odor.

- When selecting sleep mode, only the [ ] display on the control panel will be dimmed.

- Fan speed will be changed to (Sleep) during humidification and purification mode.

<Auto setting status>

ENGLISH-16

Paper_AX034HPXAWQ_IB_EN_04615A-01.indd 16 2014-02-24 오전 10:23:13

Sleep mode

When you are sleeping, the air purifier with humidification function will be turned off automatically.

While the appliance is switched on, press [ ] button and set the sleep mode.

f ] button, the time for sleep mode will be selected by 1 hour unit from continuation to 8Hr(8hours).

time and set humidity by pressing [ ] button and [ ] button.

f ] button in timer mode, the timer function will be canceled.

<When Sleep function is set>

NOTE

• When the set time is over, the air purifier with humidification function will be turned off automatically.

• After setting the timer function, if you turn the appliance off or select the continuation status for timer, the timer function will be canceled.

• When setting the timer function, the remaining time will be displayed by 1 hour unit as time goes on.

• When selecting timer function, the appliance will be changed to sleep mode.

• If you select sleep mode while operating S-plasma ion, S-plasma ion will operate even though it is not displayed.

• The mode before setting the sleep mode will operate.

• Off timer function operates only in sleep mode.

S–Plasma ion

S-Plasma ion captures the harmful materials floating in the air through HOO –

(H) with oxygen ion(O

2

– virus, and mold in the air.

that is produced by combining active hydrogen

) and destroys the hydrogen bond of protein structure to perform sterilization which removes germ, f ] button to operate S-Plasma ion.

f ] button. The S-Plasma ion display will go out.

<When S–Plasma ion function is on>

NOTE

• When you don’t use the humidification function, empty the water in the water bottle.

Paper_AX034HPXAWQ_IB_EN_04615A-01.indd 17

ENGLISH-17

2014-02-24 오전 10:23:14

OTHErS

Cleaning and maintenance

CAUTION

• Before you clean the appliance, you turn off and unplug the appliance.

Cleaning the exterior clean.

CAUTION

• Do not clean the display and button control part with alkaline detergent.

• Do not clean the surface of the appliance with sulfuric acid, hydrochloric acid or organic solvent such as thinner, kerosene, and acetone. Do not attach a sticker to the appliance as it will damage the surface of the appliance.

Maintaining the appliance with a dry cloth and then leave them to dry in the shade.

humidity level is low.

CAUTION

• If water remains in the appliance for a long time, the foreign materials in the water will combine with air, which corrodes interior of the appliance and blocks the humidity discharge as well as bacterial propagation. (When not using the appliance for a long time, remove all the water in the water bottle and from the interior of the appliance.)

Moving the appliance

(If you lift up the tray without the water bottle, the appliance may fall as the tray is pulled out.)

CAUTION

• When moving the appliance, the water bottle should be attached.(remove all the water in the water bottle and the tray.)

Paper_AX034HPXAWQ_IB_EN_04615A-01.indd 18

ENGLISH-18

2014-02-24 오전 10:23:14

Cleaning dust sensor

1. Grip the grooves of the dust sensor cover and pull the cover toward the right.

Dust sensor cover

2. Clean the dust sensor lens carefully with a cotton bud.

Dust sensor lens

3. Put the two hinge parts of the dust sensor cover into the right grooves of the dust sensor part( ①) and press the cover in the arrow direction( ②) to attach.

Dust sensor cover

CAUTION

• Do not clean the sensor part with volatile materials such as alcohol and acetone, use only water.

• When foreign material(dust) remains around the dust sensor lens, the contamination level status might not be changed from contamination status. In that case, clean the sensor again.

• Clean the sensor part every six months. However, the cleaning period can vary according to the surrounding environment and hours of usage, so this period should be shorter in a dusty environment.

Paper_AX034HPXAWQ_IB_EN_04615A-01.indd 19

ENGLISH-19

2014-02-24 오전 10:23:15

Cleaning and maintenance

Cleaning the water bottle

1. While the appliance is switched off, detach the upper cover( ①) and lift off the water bottle from water bottle box( ②).

Upper cover

Water bottle

2. Open the water bottle cap.

- Turn the bottle cap in an anti clockwise direction. Before opening the water bottle, press the port in the middle of the bottle cap to release the vacuum so the bottle cap can be opened easily.

Port

Water bottle cap

Water purification filter

3. After cleaning the water bottle with running water, leave it dry completely in the shade.

- Clean the water bottle frequently.

4. Close the water bottle cap.

- Turn the bottle cap in a clockwise direction.

5. After putting the water bottle into the water bottle box ( ①), fit the upper cover( ②).

Upper cover

Water bottle

NOTE

• When using the appliance for the first few times, the operating time might be delayed while the supply of water flows through. (Maximum 5minutes)

• Each time you supply water, check the condition of the water bottle and clean it when it is dirty.

CAUTION

• If the upper cover is not closed correctly after cleaning, the appliance will not operate correctly.

• Be careful of damage since the water bottle could be weakened by shock.When the water bottle gets damaged, do not use it as there is the danger of water leakage and you should contact a service center.

ENGLISH-20

Paper_AX034HPXAWQ_IB_EN_04615A-01.indd 20 2014-02-24 오전 10:23:15

Cleaning the water purification filter

1. After detaching the water purification filter from water bottle cap, put the filter into a bowl of tap water and clean it by shaking slowly.

2. Fit the water purification filter back into the water bottle cap.

NOTE

• Water purification filter needs to be cleaned only when the surface of the filter is polluted.

• Initial use : When you wash the filter for the first few times, sometimes the water color can be dark red but it will not cause any harm to the human body.

• Water supply : When operating the appliance for the first time, the initial operation time can be delayed since it needs time for the water supply (Maximum 5minutes).

• replacement time : The replacement time for the water purification filter can vary according to the elements of water and service life. When white powder forms in the tray or in the hydraulic turbin, purchase a new filter.

(Expected lifespan of the filter is 3~6 months.)

• Maintenance : If you are not going to use the filter for long period of time, remove it from the water bottle, dry the moisture on the surface and store it in a vinyl package.

CAUTION

• Be careful of damage since the water purification filter could be weakened by shock. When the water bottle gets damaged, do not use it as there is the danger of water leakage and contact a service center.

• Do not detach the water purification filter, do not apply impact to the filter and do not make a hole in the filter net. Otherwise, a positive ion exchange resin will get out.

• Do not drink the water purified and reserved in the appliance.

Paper_AX034HPXAWQ_IB_EN_04615A-01.indd 21

ENGLISH-21

2014-02-24 오전 10:23:16

Cleaning and maintenance

Cleaning the humidification filter

When the appliance is not cleaned for a long time, sediment powder will form on the humidification hydraulic turbin, so clean the filter frequently.

1. While the appliance is switched off, detach the upper cover( ①) and lift off the water bottle from water bottle box( ②).

Upper cover

Water bottle

2. Detach the side cover from the appliance by pulling the tray handle on the bottom right of the appliance and lift up the humidification hydraulic turbin.

3. Grip the the part marked 'Back' on the humidification hydraulic turbin and press the fastener(6 places) in the arrow direction to detach and then pull out the humidification filter.

- When reassembling the humidification hydraulic turbin, repeat the assembling procedure in reverse order.

4. Clean the humidification filter by soaking it in water. Then press the filter gently with hands and leave it to dry in the shade.

- Dissolve detergent in lukewarm water and put the filter in the water for

20~30 minutes. Then press the filter gently with hands to clean.

- rinse the filter with clean water to thoroughly remove the detergent or pollutant in the filter. (If the filter is not washed clean, it may produce an odor.)

- After cleaning the filter, leave the filter to dry in the shade.

Paper_AX034HPXAWQ_IB_EN_04615A-01.indd 22

ENGLISH-22

2014-02-24 오전 10:23:20

5. After fitting the rubber packing into the groove of the humidification hydraulic filter, the humidification filter with humidification hydraulicn turbin. When putting the humidification hydraulic turbin into the appliance, the 'Back' writing on the turbin should look at the rear side of the appliance.

6. After closing the side cover( ①), put the water bottle into the water bottle box( ②) and close the upper cover.(③)

Upper cover

Water bottle

Side cover

NOTE

• Humidification filter must be cleaned at least 2 times per week and tray and humidification hydraulic turbine must be cleaned at least 1 time per week.

• There is no front or rear side for the humidification filter.

• If the humidification filter is too dirty or there’s bad smell, dissolve detergent in lukewarm water and put the filter in the water for about and hour. Then clean the filter by rubbing or pressing it gently with hands and rinse them thoroughly before drying it completely in the shade.

• If you are not going to use the humidification function for long period of time, empty the water in the tray and the water bottle, clean and dry the humidification and store the filter in the place where it is free from other odors.

CAUTION

• When the upper cover is not closed correctly after cleaning, the appliance will not operate correctly.

• When many impurities are attahced, cleaning the humidification hydraulic turbin and the tray will be difficult and noise or product malfunctions may happen.

• rinse the humidification filter more than 3 times so that detergent does not remain on the filter.

Paper_AX034HPXAWQ_IB_EN_04615A-01.indd 23

ENGLISH-23

2014-02-24 오전 10:23:22

Cleaning and maintenance

Cleaning the tray and the interior of the appliance

If the appliance is not cleaned for a long time, sediment (powder) can form so clean the appliance frequently.

1. While the appliance is switched off, detach the upper cover( ①) and lift off the water bottle from water bottle box( ②).

Upper cover

Water bottle

2. Detacth the side cover from the appliance by gripping and pulling out the tray handle on bottom right of the appliance and then lift up the humidification hydraulic turbin in the arrow direction. Be careful not to drop water from the humidification hydraulic turbin.

3. If white powder has formed on the surface of the humidification hydraulic turbine or around the groove of the gear part, noise may be generated.

Therefore, clean those parts with a soft brush.

4. After removing the water in the tray, dry the tray, side cover and interior of the appliance with dry towel.

- When the tray is too dirty, clean the tray by using water with a neutral detergent and rinse it and dry it completely in the shade.

- Do not clean the surface of the tray with anything sharp.

5. Put the humidification hydraulic turbin into the tray. When putting the turbin into the tray, the side that 'Back' is written should look at the rear side of the product.

- When putting the humidification hydraulic turbin into the tray, fit the rear side of the turbin into the hook first and then pull the front hook to fit the turbin.

6. After closing the side cover( ①), put the water bottle into the water bottle box( ②) and close the upper cover.(③)

Upper cover

Water bottle

Side cover

NOTE

• When the upper cover is not closed correctly after cleaning, the appliance will not operate correctly.

• Clean the tray and interior of the appliance more than once a week. However, if those parts have a bad odor or become dirty, clean them more frequently.

ENGLISH-24

Paper_AX034HPXAWQ_IB_EN_04615A-01.indd 24 2014-02-24 오전 10:23:25

Cleaning the pre filter

1. While the appliance is switched off, detach the upper cover( ①) and detach the pre filter from pre filter frame.

Upper cover

Pre filter

2. Clean the pre filter with running water.

-

- When the dust is too thick, rinse the filter with warm water using neutral detergent.

3. Dry the filter completely in the shade.

- When drying the filter, it shouldn't be exposed to direct sunlight.

-

4. After putting the pre filter into the pre filter frame( cover(

-

②).

①), close the upper

Upper cover

Pre filter

NOTE

• Put the filter into the appliance as the front side look forwards.

• Clean the pre filter every 2weeks. However, the cleaning period can vary according to the surrounding environment and hours of usage, so the period should be shorter in a dusty area.

Paper_AX034HPXAWQ_IB_EN_04615A-01.indd 25

ENGLISH-25

2014-02-24 오전 10:23:27

Cleaning and maintenance

Changing HEPA filter and deodorization filter

When the filter exchange light [ ] is lit up on the control panel, change the HEPA filter and deodorization filter.

HEPA filter Deodorization filter

HEPA filter is a highly efficient filter that eliminates fine dust or cigarette particles.

Deodorization filter is a highly efficient filter that eliminates smells from everyday living such as the bathroom or food.

1. While the appliance is switched off, detach the upper cover( ①) and pull out the filter frame that is in front of pre filter( ②).

Upper cover

Filter frame

2. Pull out the HEPA filter and deodorization filter from the filter frame.

- After pulling out the HEPA filter, you can pull out the deodorization filter.

Filter handle

3. Put the new HEPA and deodorization filter into the filter frame.

- If you touch the deodorization filter by hands, your hands will be dirty.

Put on gloves before you change the filters.

- When putting the HEPA filter and deodorization filter into the filter frame, put the deodorization filter first and then HEPA filter.

4. After putting the filter frame back( ①), close the upper cover(②).

- When putting the filter frame back, check the inserting direction.

Upper cover

Filter frame

5. After turning the appliance on, press [ ] button and [ ] button at the same time for 3 seconds.

- The filter exchange light on the control panel will go out with a beep sound and the light will be on again for next exchange period.

NOTE

• Exchange filter can be purchased at a Samsung service center.

CAUTION

• The HEPA filter and deodorization filter shouldn’t be cleaned or touched with water.

ENGLISH-26

Paper_AX034HPXAWQ_IB_EN_04615A-01.indd 26 2014-02-24 오전 10:23:28

Troubleshooting

Before reporting the problems of your appliance, please check the trouble shooting table below.

Problem

The air purifier with humidification function does not work at all.

HEPA filter or deodorization filter exchange display is on continuously.

Odor is generated.

Solution

• Check if there is a power failure. After checking the status of power supply, operate the appliance again.

• Check if the power plug is properly connected.

Insert the power plug into the wall socket correctly and operate the appliance again.

• Check if the power socket has a problem and use another socket.

• Check if the upper cover is correctly closed.

• Check if you pressed the [ ] button and the

[ ] button at the same time for more than

3 seconds. When exchanging the filters, press the

[ ] button and the [ ] button for 3 seconds until you hear a beep sound.

• Check if you haven’t cleaned the appliance for a long time or used stale water. Clean the water bottle, humidification filter and the interior of the appliance.

• Check if the odor is similar to that of chlorine.

• The odor may be from the chlorine contained in the water. (Place the water outside for about one day and then supply the water again.)

• Check if the pre filter is dirty and then clean the pre filter.

• Check if the odor is generated from HEPA filter or deodorization filter and then change the two filters.

ENGLISH-27

Paper_AX034HPXAWQ_IB_EN_04615A-01.indd 27 2014-02-24 오전 10:23:28

Troubleshooting

Problem

Water is not supplied.

The humidity level does not go up to set humidity level in humidification mode.

The water bottle runs out of water but [Water supply] light is not lit up.

Breeze is generated but the moisture is not.

Solution

• Check if the water bottle is properly fitted into the water bottle box.

• Check the water supply after removing the purification filter from the water bottle.

• Check whether the indoor room is warm or windows are open.

• Especially, the humidity level is very low in the winter as the appliance is used in a sealed room.

Therefore, the current humidity level might not go up to the high humidity level set by users.

❋ ❋ This is not the product malfunction, but just the difference depending on the usage environment.

• Check if water remains in the tray. When the water in the tray is removed, the water supply light [   ] will be lit up as well as the water bottle.

After removing all the water in the tray, operate the applaince and check whether the [   ] light is lit up in 3~5 minutes.

• Check if the humidification mode is off. If the humidification light is off, the humidification function will not work, so after checking it, change it to the humidification mode.

• Since this appliance is an evaporative air purifier with humidification function, the vapor is invisible. Even if you cannot see the vapor from the appliance, do not worry about product malfunction.

ENGLISH-28

Paper_AX034HPXAWQ_IB_EN_04615A-01.indd 28 2014-02-24 오전 10:23:28

Problem

Less moisture is generated.

Strange noise is generated.

Error is indicated.

Solution

• Check if you used well / spring water and then change it to tap water.

• Check if the water in the water bottle is freezing or too cold. Use water of 7 °C~15 °C after

10~15minutes is passed. When using the water lower than 6 °C, product malfunction may occur.

• Check if the hydrulic turbin fits correctly. When putting the turbin into the appliance, the side with toothed wheel should look forward.

• Check if it is electrical noise. The electrical noise may be generated during the ion production.

Therefore, do not worry about malfunction with this noise.

• Check if it is mechanical noise. Check if the hydraulic turbine and tray are dirty with white powder. Purchase a new water purification filter and replace it. Clean the humidification hydraulic turbine and tray on a regular basis. Especially, when there is white powder around the groove of the humidification hydraulic turbine gear part, clean it with a soft brush as the white powder causes a noise.

• Are the hydraulic turbin or tray dirty with white powder?

• messagess are displayed on the timer diplay of the control panel. In this case, the appliance has a certain problem, so contact the service center.

Paper_AX034HPXAWQ_IB_EN_04615A-01.indd 29

ENGLISH-29

2014-02-24 오전 10:23:28

Memo

Paper_AX034HPXAWQ_IB_EN_04615A-01.indd 30

ENGLISH-30

2014-02-24 오전 10:23:28

Memo

Paper_AX034HPXAWQ_IB_EN_04615A-01.indd 31

ENGLISH-31

2014-02-24 오전 10:23:28

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

Download PDF

advertisement