Kudos Bow Pivot Shower Enclosure Installation Instructions
Below you will find brief information for Shower Enclosure Bow Pivot. This Shower Enclosure offers a refreshing innovation for your showering experience with its sleek design and easy installation. The Bow Pivot design allows for smooth operation and a stylish look. The enclosure is designed to be easily installed and adjusted, ensuring a perfect fit for your bathroom. Ensure you waterproof your walls before installing the Shower Enclosure, and use the silicone sealant to ensure a leak-proof seal around your shower tray.
PDF
Download
Document
Advertisement
Advertisement
ORIGINAL RANGE KUDOS BOW PIVOT REFRESHING INNOVATION IN SHOWERS Installation Instructions Please read these instructions before installing, as incorrect fitting will invalidate the guarantee. Carry out each stage before moving onto the next. Do not dispose of packaging, no claims for damaged or missing parts will be accepted if the packaging has been disposed of. If you are unsure about these instructions please contact Kudos Shower Products: Customer Service Helpline: 01539 564040 KEY STAGES TOOLS REQUIRED ? Flat-Headed Screwdriver ? Pozi-Drive Screwdriver ? Spirit Level ? Tape Measure ? Silicone Sealant ? 4mm Allen Key (Supplied) ? Electric Drill ? 7mm Drill Bit (Masonry) ? Junior Hacksaw ? Decide handing of the door ? Remove the door glass ? Fit height adjusters ? Position and level the frame work in situ ? Drill walls and fix connector posts ? Adjust wall posts to ensure vertical ? Re-fit door glass and adjust ? Silicone seal the enclosure IMPORTANT Check appearance of shower enclosure - any defects must be Prior to tiling, any gap or crevice between the rim of the tray and reported to Kudos Shower Products before assembly/installation the wall must be filled with silicone sealant flush with the rim of the Claims for imperfections will only be accepted prior to tray - see Fig.1 assembly/installation Waterproof the walls using ceramic tiles/shower panels etc. before Any claims made under the terms of the Lifetime Guarantee installation of the shower enclosure must be reported to Kudos within 21 days of the fault occurring Fully seal between tiles/shower panels and the tray BEFORE installing the enclosure - see Fig.2 Check the enclosure adjustment sizes are suitable for your installation Use care when drilling into the walls to avoid hidden pipes or Ensure the top of shower tray is level in all directions electric cables Once the tray is installed but before the tiles are fitted any crevice between the tray and the walls must be filled with silicone sealant flush with the top of the tray. SILICONE SEALANT FIG.1 FIG.2 Once the walls have been tiled but before the enclosure is installed, the tiles must be silicone sealed to the tray all of the way around in one continuous bead. CLEANING GENERAL - for the frame work and fixings use only warm soapy water and damp cloth/ sponge on a regular basis. After cleaning please rinse with clean water to remove any residue. Do not use abrasive scouring powders, chemicals or aerosol cleaners - these may result in damage to the surfaces, in particular, the plated component parts. See instruction below for glass cleaning advice. LIFESHIELD Your Kudos Product is pre-treated with Life Shield on the inside surfaces only. While this makes cleaning the glass a lot easier and helps prevent the build up of harmful lime-scale and soap deposits the glass still needs to be maintained on a regular basis. We recommend the use of a detergent and aroma free glass cleaner (A 50/50 mix of Vinegar and Water works well!!). Strong detergents and abrasives can damage the coating. DO NOT use abrasive cleaners or abrasive scrubbing equipment for cleaning!! DO use a squeegee to remove remaining droplets of water from glass after showering, any build up of residue can be removed easily using an appropriate cleaner and agitation from soft cleaning equipment THESE INSTRUCTIONS TO BE LEFT WITH THE CUSTOMER IMPORTANT- If you are installing a side panel together with this door, please read these instructions in conjunction with the side panel installation instructions 5 REMOVE CLIP-IN EXTRUSIONS from wallposts on each side of the unit. B A CONTENTS Carefully remove unit, installation pack, handle and seals from packaging. 1 C OUTSIDE RELEASING CLIP-IN EXTRUSION ON PIVOT SIDE REMOVE CONNECTOR POSTS These simply unclip from each wallpost on each side of unit. A C B OUTSIDE RELEASING CLIP-IN EXTRUSION ON DOOR OPENING SIDE 2 HANDING OF UNIT The door can be fitted to open from the left or right hand side. Simply (and carefully) turn unit upside down to suit your installation. Opening Side Pivot Side Left hand opening door 3 Pivot Side Opening Side A- press along length of clip-in extrusion as shown to release B- ease clip-in extrusion out of wallpost C- lift out and away 6 CURVED FACE TO INSIDE 7 POSITION FRAME ONTO TRAY, holding each side of frame, carefully position centrally onto tray. 8 EXPAND FRAME WIDTH equally on both sides by turning the nylon adjustment screws (3 in each wall post) in an anticlockwise direction, until unit is lightly wedged into position. NB- turning these screws force the compensating channel outwards to increase the width of the door-max. 15mm adjustment in each wall post. 9 SET FRAME LEVEL, if necessary, by turning relevant height adjuster screw (clockwise to raise). Use spirit level to ensure accurate levelling. NB- turning the screw will raise that side of the unit off the tray, there is 5mm adjustment in each height adjuster. Right hand opening door REMOVE DOOR GLASS Using 4mm Allen key provided, remove the screw and pivot patch from top of door. Carefully lift glass up and out of frame, taking care not to damage the pivot mechanism at bottom of door. Remove top pivot body. 3.2 3.1 TOP OF DOOR 3.3 TIP REMOVE PIVOT BODY 4 INSERT HEIGHT ADJUSTERS, into the bottom of each wallpost INSERT SPIRAL CAM INTO HOLE AS INDICATED, ENSURE CAM IS ORIENTATED AS SHOWN SLIDE HEIGHT ADJUSTER INTO FRAME AND OVER SPIRAL CAM. IT PUSH HEIGHT ADJUSTER FULLY INTO FRAME, FLUSH WITH RE-FIT CONNECTOR POSTS, to wall posts ensuring curved faces are to inside of unit. 10 If there is a gap between underside of bottom curved rail and top of tray select shim from strip supplied, break off and insert under rail at pivot body position . This will support rail when glass is fitted. The shim will be concealed by silicone sealant later. MARK POSITION of connector posts onto walls at bottom. NB- if height adjusters were utilised, mark position of base of connector post onto wall. Carefully remove unit from tray. Shim Strip MARK INNER EDGE AND BOTTOM AS SHOWN 11 REMOVE CONNECTOR POSTS from unit and re-position these to marks made on walls. Using spirit level to ensure posts are vertical, mark through the 3 pre-punched slotted holes in each post, be sure to mark at centre of each slotted hole. cL cL C B A Mark slotted holes on centre point as shown OUTSIDE RE-FITTING CLIP-IN EXTRUSION ON DOOR OPENING SIDE 12 DRILL HOLES in walls using 7mm masonry drill and fit wall plugs supplied, or fixings suitable for the construction of your wall. FIX CONNECTOR POSTS to walls, ensuring curved face is to inside, using six-No. 8’s x 30mm long-panhead screws provided (3 in each wallpost). CURVED FACE A- Offer leading edge to wall post ensuring correct face to outside B- Ensure leading edge is fully located into all plastic clips C- Press clip-in extrusion until it “clips” into wall post. 17 FIT THE HANDLE: Layout of Handle Note: shorter end of inner handle to face inward UNIT TO CONNECTOR POSTS, 13 FIX ensuring that the compensating channels Fix this end first see 1 below Closing side of Door in wallposts fully engage into the connector posts. Fix unit to connector posts using six-No.8’s x 30mm longpanhead screws, through wall post mouldings into pre-drilled holes in connector posts (3 each side). Do not overtighten these screws. Panel side of door FRAME is level, vertical and 14 CHECK square on all sides of the unit, frame must TIP 15 not be twisted. Using spirit level check wall posts are vertical and straight, (use adjustment screws as described in stage 8, as necessary). Use clip-in extrusions as straight edges to ensure wall posts are straight. 3) Offer handle into hole in door glass on closing side with small inside handle. ENSURE THREAD IS IN CENTRE OF GLASS HOLE. 4) Screw small inside handle into larger outer handle. Screw until hand tight and inner handle is horizontal. DO NOT OVER TIGHTEN 18 Still holding the glass offer the top pivot screw plate into position on the outside and insert screw to secure using Allen key provided. You may now release hold of the glass. 16 2) Screw fix with M6x30mm using 4mm Allen key (supplied) Do not fully tighten yet. FIT DOOR GLASS by carefully lifting glass into frame and inserting bottom pivot spindle into the pivot body on the bottom curved rail. Take care not to damage pivot body in locating spindle into hole. Do not leave go of the glass at this time. While holding the glass securely in place, offer the top pivot spindle into position on inside with the spindle pushed into the top pivot body on the curved top rail. TIP 1) Position Handle over hole in glass nearest to the Panel side. Fit screw plate from inside. INSIDE Stand on outside of unit when fitting glass as pivot screw plates fix from outside. If working alone, place components on top of frame to access these when required. RE-FIT CLIP IN EXTRUSIONS, to the wall posts each side ensuring the leading edge is properly located along the full height before pressing it into the wall post - it will not engage properly if twisted. A PLASTIC CLIP B CLOSE THE DOOR The glass, on the opening side, should wipe across the flipper seal evenly from top to bottom. C OUTSIDE RE-FITTING CLIP-IN EXTRUSION ON PIVOT SIDE Rear Seal Flipper Seal Glass OUTSIDE IF THIS IS NOT THE CASE: If necessary the glass can be adjusted to the left or right to increase or decrease the interference with the flipper seal - loosen pivot screw at top and/or bottom, adjust door and re-tighten screws. Please refer to next stage, overleaf, if further adjustment is required to achieve the correct closing action. 19 IF CLOSING ACTION IS TOO LOOSE: If still too loose, remove clip-in extrusions on opening side and adjust centre adjustment screw outwards (anti-clockwise) by 1 to 2 turns to bring frame closer to the glass at mid height of door. FIT PIVOT COVER CAPS 22 Slide pivot cover caps over inside and outside faces of the pivot parts. The caps will ‘snap’ into position when fully home and will not slide off. Centre adjustment screw Slide Over 23 20 CHECK CLOSING ACTION DOOR If the glass does not touch the rear seal, (diagram at stage 18), evenly over the full height when closed, it is possible the curved glass is slightly twisted. NB-This is normal and within the glass manufacturers standard tolerances for curved glass. To compensate for this it is necessary to re-adjust the frame, this requires that you remove the clip-in extrusions from both sides. There are 3 access holes in each wallpost through which you can reach the wall fixing screws, which were used to fix the connector posts to the wall. IF THE GLASS DOES NOT TOUCH THE REAR SEAL AT THE TOP Release the top wall fixing screw on the opening side and adjust the frame outwards. For further adjustment, release the bottom fixing screw on the pivot side and adjust the frame outwards. Re-tighten screws and re-fit clip-in extrusions. See screw positions ‘A’ ACCESS HOLE FOR WALL FIXING SCREW LONGER SEAL Leg to face outside of enclosure B A 21 SHORTER SEAL Leg to face inside of enclosure 24 TEST SEAL ACTION WHEN OPENING DOOR Open and close the door and check to ensure seal action is a smooth sweeping action on frame. If the seal catches or snags check the seal is fully pushed onto the glass edge. TIP If seal is tight at opening side, it may be necessary to add more shim under rail (refer to stage 9) to raise the glass door. 25 IF THE GLASS DOES NOT TOUCH THE REAR SEAL AT THE BOTTOM Release the bottom wall fixing screw on the opening side and adjust the frame outwards. For further adjustment, release the top fixing screw on the pivot side and adjust the frame outwards. Re-tighten screws and re-fit clip-in extrusions. See screw positions ‘B’ FIT BOTTOM SEAL This needs to be measured and cut to size. First measure from closing edge of glass to side of pivot component. Then cut a length equal to this from the seal supplied. Slide the seal onto bottom edge of glass ensuring this is pushed firmly all the way onto the glass and tight against the pivot cover cap. Next measure short length from inside edge of vertical seal, on pivot side of glass to side of pivot component and repeat as above. SILICONE SEAL UNIT, to walls and tray. OUTSIDE AND OUTSIDE ONLY Silicone seal wallposts to wall on inside and outside Silicone seal frame to tray and joints as shown on outside only A B FIT TOP COVER CAPS 1 1 1. Fit connector post cap-push fit. 2 3 2 2. Fit channel cappush fit. 3 3. Fit top cap screw fixno.4x10mm csk screws. IMPORTANT Do not silicone seal on the inside of unit (except where shown). Sealing the wallposts & rails to the tray on the inside can result in leakage problems-please note that, in use, water can penetrate into the frame extrusions-this has no detrimental effect to the product-however, this water must be allowed to drain out of the extrusions to the inside. Allow 24 hours for the silicone to cure before using the shower. V10-01 ">
Advertisement
Key Features
- Bow Pivot design
- Adjustable frame width
- Height adjustable
- Easy to install and adjust
- Lifetime Guarantee
Frequently asked questions
How to clean the Shower Enclosure glass?
Use a detergent and aroma free glass cleaner (A 50/50 mix of Vinegar and Water works well!!). Avoid using abrasive cleaners or abrasive scrubbing equipment.
What should I do if the glass does not touch the rear seal?
It is possible that the curved glass is slightly twisted, re-adjust the frame by releasing the wall fixing screws and adjusting the frame outwards. Re-tighten screws and re-fit clip-in extrusions.
Where should I apply silicone sealant for sealing?
Silicone seal wallposts to the wall on the inside and outside. Silicone seal the frame to the tray and joints as shown on the outside only.