Ordering Information
I/O Block Base
G70A
Reduces Wiring while Providing I/O
Flexibility
• Mount I/O relays and I/O SSRs freely.
• Electric-shock preventive (finger-touch protection) terminal
block incorporated conforming to VDE 0160.
• Connects to the PC and SBC easily via a connector.
• DIN track mounted.
• I/O Block conforming to VDE 0160.
Ordering Information
■ List of Models
Classification
Output
Input
Internal I/O circuit common
Rated voltage
Model
NPN (+ common)
24 VDC
G70A-ZOC16-3
PNP (– common)
24 VDC
G70A-ZOC16-4
NPN/PNP
110 VDC max., 240 VAC max.
(See note)
G70A-ZIM16-5
Note: Each relay to be mounted must incorporate a coil that has proper specifications within the maximum rated voltage range.
■ Suitable Relay/SSR
Classification
I/O Block Base
PCB Relay
Solid State Relay
Output
NPN:G70A-ZOC16-3
PNP:G70A-ZOC16-4
G2R-1-S
G2R-1-SN
G3R-OA202SZN
G3R-OA202SLN
G3R-ODX02SN
G3R-OD201SN
G3RZ-201SLN
H3RN-1
H3RN-11
Input
G70A-ZIM16-5
G2R-1A3-SN
G2R-13-SN
G2R-1A3-SND
G2R-13-SND
G3R-IAZR1SN
G3R-IDZR1SN
G3R-IDZR1SN-1
Note: G2R-13-SN has twin cross-bar contacts.
■ Connecting Sockets for I/O Terminal Expansion
Model
Number of poles
P2RF-05-E
1 pole (G2R: 1 pole usage)
P2RF-08-E
2 poles (G2R: 2 poles usage)
■ Accessories (Order Separately)
G78-16-E Short Bar
Applicable model
G70A-ZOC16-3
G70A-ZOC16-4
Model
G78-16-E
G70A-ZIM16-5
I/O Block Base
G70A
1
Specifications
■ Ratings/Characteristics
Item
G70A-ZOC16-3
G70A-ZOC16-4
G70A-ZIM16-5
Contact resistance
10 mΩ (excluding the resistance of the relay to be used)
Permissible current
10 A
100 mA
Max. operating voltage
380 VAC, 125 VDC
30 VDC
Dielectric strength
4,000 VAC, 50/60 Hz for 1 min between connector and
output terminals
2,000 VAC, 50/60 Hz for 1 min between output terminals
250 VAC, 50/60 Hz for 1 min between connectors
4,000 VAC, 50/60 Hz for 1 min between connector and
input terminals
2,000 VAC, 50/60 Hz for 1 min between coil terminals
250 VAC, 50/60 Hz for 1 min between connectors
Insulation resistance
Between connector and I/O terminals: 1,000 MΩ (at 500 V)
Other: 100 MΩ (at 500 V)
Vibration resistance
Malfunction: 10 to 61.2 to 10 Hz, 0.1-mm single amplitude (0.2-mm double amplitude); 61.2 to 150 to 61.2 Hz,
14.7 m/s2
Shock resistance
Malfunction: 200 m/s2
Noise immunity
Noise level: 2.0 kV; pulse width: 100 ns to 1 µs
Ambient temperature
Operating: 0°C to 55°C (with no icing)
Ambient humidity
Operating: 35% to 85%
Coil surge absorption element
Diode: 1 A, 400 V
Protection diode for inverse
connection
Diode (2 A, withstand inverse voltage: 40 V)
Tightening torque
0.59 N·m
Varistor (see note)
Note: Use a DC relay with a built-in diode because a DC relay without a built-in diode does not absorb any coil surge.
■ Relay (G2R-1-S, G2R-1-SN)
Coil Ratings
Rated voltage
24 VDC
Rated current
21.8 mA
1,100 Ω
Coil resistance
Coil inductance
Armature OFF
4.27
(H) (ref. value)
Armature ON
8.55
Must operate voltage
70% min. of rated voltage
Must release voltage
15% min. of rated voltage
Max. voltage
110% of rated voltage
Power consumption
Approx. 0.53 W
Contact Ratings
Number of poles
1 pole
Load
Resistive load (cosφ = 1)
Inductive load (cosφ = 0.4; L/R = 7 ms)
Rated load
10 A at 250 VAC; 10 A at 30 VDC
7.5 A at 250 VAC; 5 A at 30 VDC
Rated carry current
10 A
Max. operating voltage
380 VAC, 125 VDC
Max. operating current
10 A
Max. switching capacity
2,500 VA, 300 W
Min. permissible load
100 mA at 5 VDC
2
I/O Block Base G70A
1,875 VA, 150 W
■ Relay (G2R-1A3-SN (SND), G2R-13-SN (SND))
Coil Ratings
Rated voltage
Rated current
230 VAC
12 VDC
24 VDC
50 Hz
3.7 mA
43.6 mA
21.8 mA
60 Hz
3.1 mA
1,100 Ω
Coil resistance
30,000 Ω
275 Ω
Must operate voltage
80% max. of rated voltage
70% max. of rated voltage
Must release voltage
30% min. of rated voltage
15% min. of rated voltage
Max. voltage
110% of rated voltage
Power consumption
Approx. 0.7 W (60 Hz)
Approx. 0.53 W
Note: 1. The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of +15%/–20% (AC rated current) or ±10%
(DC coil resistance).
2. LEDs are used for the built-in operation indicator. For models equipped with these indications, the VAC rated current must be increased
by approximately 1 mA; the VDC rated current, by approximately 4 mA.
3. Operating characteristics are measured at a coil temperature of 23°C.
Contact Ratings
Refer to Ratings/Characteristics of G70A-ZIM16-5.
■ SSR
Ratings
Input Module
Input
Model
Rated voltage
Operating voltage
Input current
Must operate voltage Must release voltage
G3R-IAZR1SN
100 to 240 VAC
60 to 264 VAC
15 mA max.
60 VAC max.
G3R-IDZR1SN
5 VDC
4 to 6 VDC
8 mA max.
4 VDC max.
1 VDC min.
12 to 24 VDC
6.6 to 32 VDC
6.6 VDC max.
3.6 VDC min.
G3R-IDZR1SN-1
20 VAC min.
5 VDC
4 to 6 VDC
4 VDC max.
1 VDC min.
12 to 24 VDC
6.6 to 32 VDC
6.6 VDC max.
3.6 VDC min.
Output
Model
Logic level supply voltage
G3R-IAZR1SN
4 to 32 VDC
Logic level supply current
0.1 to 100 mA
G3R-IDZR1SN
G3R-IDZR1SN-1
Output Module
Input
Model
G3R-OA202SZN
Rated voltage
5 to 24 VDC
Operating voltage
4 to 32 VDC
Input current
G3R-OA202SLN
15 mA max.
(at 25°C)
G3R-ODX02SN
8 mA max.
Must operate voltage Must release voltage
4 VDC max.
1 VDC min.
G3R-OD201SN
Output
Model
G3R-OA202SZN
Load voltage
75 to 264 VAC
Load current (see note)
Inrush current
0.05 to 2 A
30 A (60 Hz, 1 cycle)
G3R-OA202SLN
G3R-ODX02SN
4 to 60 VDC
0.01 to 2 A
8 A (10 ms)
G3R-OD201SN
40 to 200 VDC
0.01 to 1.5 A
8 A (10 ms)
Note: The minimum current value is measured at 10°C min.
I/O Block Base
G70A
3
■ Characteristics
Input Module
Item
G3R-IAZR1SN
G3R-IDZR1SN
0.1 ms max.
G3R-IDZR1SN-1
Operate time
20 ms max.
15 ms max.
Release time
20 ms max.
0.1 ms max.
15 ms max.
Response frequency
10 Hz
1 kHz
10 Hz
Output ON voltage drop
1.6 V max.
Leakage current
5 µA max.
Insulation resistance
100 MΩ min. between input and output
Dielectric strength
4,000 VAC, 50/60 Hz for 1 min between input and output
Vibration resistance
10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude)
Shock resistance
1,000 m/s2
Ambient temperature
Operating: –30°C to 80°C (with no icing)
Storage: –30°C to 100°C (with no icing)
Approved standards
UL508 File No. E64562
CSA C22.2 (No. 14, No. 950) File No. LR35535
TÜV File No. R9650094 (EN60950)
Ambient humidity
Operating: 45% to 85%
Weight
Approx. 18 g
Output Module
Item
G3R-OA202SZN
G3R-OA202SLN
G3R-ODX02SN
Operate time
1/2 of load power source 1 ms max.
cycle + 1 ms max.
Release time
1/2 of load power source cycle + 1 ms max.
2 ms max.
Response frequency
20 Hz
100 Hz
Output ON voltage drop
1.6 V max.
Leakage current
1.5 mA max.
G3R-OD201SN
2.5 V max.
1 mA max.
Insulation resistance
100 MΩ min. between input and output
Dielectric strength
4,000 VAC, 50/60 Hz for 1 min between input and output
Vibration resistance
10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude)
Shock resistance
1,000 m/s2
Ambient temperature
Operating: –30°C to 80°C (with no icing)
Storage: –30°C to 100°C (with no icing)
Approved standards
UL508 File No. E64562
CSA C22.2 (No. 14, No. 950) File No. LR35535
TÜV File No. R9650094 (EN60950)
Ambient humidity
Operating: 45% to 85%
Weight
Approx. 18 g
Engineering Data
■ When Mounted to a G2R
Maximum Switching Power
Endurance
500
250 VAC resistive load
30 VDC resistive load
100
250 VAC inductive load
(cosφ=0.4)
50
Switching current (A)
Endurance (×104 operations)
G2R-1A-S (24 VDC)
Note:
AC resistive load
10
5
DC resistive load
10
5
DC inductive load
(L/R=7ms)
1
30 VDC inductive load
(L/R=7ms)
0.5
AC inductive load
(cosφ=0.4)
0
4
2
4
5
6
7.5 8
10
12
14
Switching current (A)
I/O Block Base G70A
0.1
0
5
10 20 30 50
100
500
Switching voltage (V)
The characteristics shown here are for 16-point mounting.
This data was produced from actual values sampled on
production lines, and should be used for reference
purposes only.
Since relays are mass-produced, a certain amount of
tolerance is generally allowed in their application.
■ When Mounted to a G3RZ
Inrush Current Resistivity
Load Current vs. Ambient
Temperature
Non-repetitive (Keep the inrush current to half the
rated value if it occurs repetitively.)
G3RZ-201SLN
Inrush current (A. peak)
Load current (A)
G3RZ-201SLN
1.4
1.2
1
0.8
14
12
10
8
0.7
0.6
6
0.4
4
0.2
2
0
−30 −20
0
20
0
5
40 55 60
80
100
Ambient temperature (°C)
10
30 50
100
300 500 1,000 3,000 5,000 10,000
Energizing time (ms)
■ When Mounted to a G3R
Load Current vs. Ambient Temperature
G3R-ODX02SN
2.5
Single mounting
2
16-point mounting
G3R-OD201SN
3
3
Load current (A)
3
Load current (A)
Load current (A)
G3R-OA202SZN
G3R-OA202SLN
2.5
Single mounting
2
2.5
2
Single mounting
16-point mounting
1.5
1.5
1.5
1
1
1
0.7
0.5
0.5
0.6
0.5
0
−30 −20
0
0
−30 −20
20 30 40 55 60
80
100
Ambient temperature (°C)
0
20
16-point mounting
0
−30 −20
40 55 60
80
100
Ambient temperature (°C)
0
20
40 55 60
80
100
Ambient temperature (°C)
Inrush Current Resistivity
Non-repetitive (Keep the inrush current to half the
rated value if it occurs repetitively.)
G3R-ODX02SN
30
20
10
0
10
30 50
100 200
500 1,000
5,000
Energizing time (ms)
G3R-OD201SN
15
Inrush current (A)
Inrush current (A)
Inrush current (A. peak)
G3R-OA202SZN
G3R-OA202SLN
14
13
12
11
10
15
14
13
12
11
10
9
9
8
8
7
7
6
6
5
5
4
4
3
3
2
2
1
0
10
30 50
100
300 500 1,000 2,000
Energizing time (ms)
1
0
10
30 50
100
I/O Block Base
300 500 1,000 2,000
Energizing time (ms)
G70A
5
Dimensions
Note: All units are in millimeters unless otherwise indicated.
G70A-ZOC16 (Output)
234
64
75
35.5−8.2
28.6
M3.5
9.2 19.6
20.7
34.2
48.7
G70A-ZIM16 (Input)
234
48.7
10.2
35.5−8.2
75
M3.5
9.2 19.6
20.7
34.2
54
6
I/O Block Base G70A
Terminal Arrangement/Internal Connection
G70A-ZOC16-3 (NPN)
Connector Terminal (+)* (−)*
Arrangement
(Top View)
*Recommended DC power supply; eg OMRON S8VS
G70A-ZOC16-4 (PNP)
(+)* (−)*
Connector Terminal
Arrangement
(Top View)
*Recommended DC power supply; eg OMRON S8VS
I/O Block Base
G70A
7
G70A-ZIM16-5 (NPN/PNP)
1A1
2A1
1A2
COM.
3A1
2A2
4A1
3A2
5A1
4A2
6A1
5A2
7A1
6A2
8A1
7A2
9A1
8A2
10A1
9A2
11A1
10A2
12A1
11A2
13A1
12A2
14A1
13A2
15A1
14A2
16A1
15A2
16A2
Connector Terminal
Arrangement
(Top View)
14
24
12
+
−
11
34
22
21
44
32
31
64
52
51
74
62
61
84
72
71
94
82
81
104
92
91
114
102
101
124
112
111
134
122
121
144
132
131
154
142
141
AC
(DC power also possible)
Independent common also possible
164
152
151
L32
L31
L30
L29
L28
L27
L26
L25
L24
L23
L22
L21
L20
L19
L18
L17
L16
L15
L14
L13
L12
L11
L9
54
42
41
L10
L8
L7
L6
L5
L4
L3
L2
L1
When mounted to a G2R-1-S
162
161
24 VDC
(Power supply) Recommended Power supply; eg. OMRON S8VS
Note: The above diagram shows the Unit mounted to a G2R-1-S.
When mounting to a [email protected] or G3RZ-201SLN, pins 11 to 14 are output terminals.
When mounting to a [email protected], pin 14 is a plus terminal and pin 11 is a minus terminal. When mounting to
G3RZ-201SLN, there is no polarity.
Cat. No. J087-E1-03
In the interest of product improvement, specifications are subject to change without notice.
OMRON EUROPE B.V.
Wegalaan 67-69,
NL-2132 JD, Hoofddorp,
The Netherlands
Phone: +31 23 568 13 00
Fax: +31 23 568 13 88
www.eu.omron.com
I/O Block Base G70A
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement