water quality monitoring
WATER QUALITY MONITORING
Table of Contents
Pocket Testers
Oakton Pocket Testers
Turbidity Meters
2020 Turbity Meter & 3000 Turbidity, Chlorine and Colorimeter
EPA Compliant Turbidity Meter
Analite Nep160 Turbidity Meter
Databank Handheld Datalogger
Colorimeters/Photometers
Flexible Photometers for Lab or Field
Single Wavelength Colorimeters
SMART Spectro Spectrophotometer
Handheld Meters
YSI ProDSS Multiparameter Sampling Instrument
YSI ProODO Dissolved Oxygen
Handheld Optical Dissolved Oxygen Meter
YSI Professional Plus
Fluorometers
Trilogy Laboratory Fluorometer
10-AU Field Fluorometer
Cyclops–7 Submersible Sensors
C-3 Submersible Fluorometer
C-6 Multi-Sensor Platform
PhytoFlash Active Fluorometer
UV Nitrate Analyzer
SUNA (Submersible Ultraviolet Nitrate Analyzer)
page 4
page 5
page 8
page 9
page 10
page 11
page 13
page 14
page 18
page 21
page 23
page 25
page 27
page 29
page 31
page 33
page 34
page 36
page 38
page 40
Sondes
HOBO U26 Optical Dissolved Oxygen Logger
HOBO Conductivity Data Logger
EXO - Advanced Water Quality Monitoring Platform
YSI 600QS (Quick Sample™)
Analite Nep495 Turbidity & Temperature Logging Probe
600OMS V2 Optical Monitoring System
600XL V2-1 and 600XLM V2-1 Sondes
YSI 6820 and 6920 V2 Sondes
YSI 6600 V2 Sonde
6600 EDS Extended Deployment System
YSI 6500 Monitoring System
YSI 6-Series Anti-Fouling Kits
YSI Oil in Water Sensor Adapter Kit
Buoys
page 41
page 43
page 45
page 48
page 50
page 52
page 54
page 56
page 58
page 60
page 62
page 65
page 67
EMM68 Buoy
EMM350 Buoy
page 69
page 71
YSI Castaway CTD
page 73
page 75
Autonomous Underwater Vehicles
Ecomapper AUV
Specialized Oxygen Sensors
Presens Non-Invasive Oxygen Sensors
Presens Oxygen Microsensors
Presens Imaging Solutions Visisens
page 77
page 79
page 81
page 83
Oakton Pocket Testers
Great for water, wastewater, laboratory or plant use, these multiparameter Testers feature longlife pH electrodes with a wide range of sample compatibility. Pin-style conductivity sensors
feature stainless steel electrodes for chemical resistance and durability. Replaceable sensor
module saves you money by reusing the meter body.Advanced features include auto-shutoff,
user-adjustable temperature coefficient, and low-battery indicator.
WD-35634-30
OAKTON
®
Waterproof pHTestr
TM
30 with double-junction
pH Range: -1.00 to 15.00pH, ±0.01 pH (resolution 0.01 pH)
Temperature Display: 0 to 50°C (32 to 122°F)
The pHTestr 30 features three-point calibration, simultaneous temperature display and a
replaceable double-junction electrode.
Includes:detachable electrode sensor, batteries and instructions.
WD-35662-35
Oakton Portable Waterproof ECTestr 11+.
Conductivity Range: 0 to 200.0 μS, 0 to 2000 μS, 0 to 20.00 mS
Conductivity Resolution: 0.1 μS, 1 μS, 0.01 mS
Conductivity Accuracy: ±1% full-scale
Temperature Range: 0 to 50°C, ±0.5°C (resolution 0.1°C)
The ECTestr 11+ offers One-point push-button calibration and is waterproof and dustproof.
Replaces ECTestr Pure+, ECTestr Low+, and the ECTestr High+, making all three separate
scales selectable in one portable large display tester.
Includes: protective plastic storage case, lanyard, and batteries.
WD-35425-00
Oakton PCTestr 35 Portable Waterproof pH and Conductivity Tester.
pH Range: 0.0 to 14.0 pH, ±0.1 pH (resolution 0.1 pH).
Conductivity Ranges: 0 to 1999 S/cm; 2.00 to 20.00 ms/cm, ±1% full scale (resolution 1
S/cm; 0.01 mS/cm).
Temperature Display: 0 to 50°C (32 to 122°F)
The PCTestr 35 features up to five-point pH calibration, conductivity auto ranging based on the
concentration of your sample, simultaneous temperature display and a replaceable sensor unit.
Includes: detachable sensor, clear plastic case, batteries and instructions.
4
TC-3000 - Turbidity, Chlorine & Colour
TC-2020 - Turbidity
TC-3000 Tri Meters
TC-3000e Kit t Order Code 1964-EPA
Turbidity, Chlorine, and Color meter, turbidity complies with
USEPA 180.1 Standard
TC-3000i Kit t Order Code 1964-ISO
Turbidity, Chlorine, and Color meter, turbidity complies with
ISO 7027 Standard
Six detector design allows for
long-term stability over a
wide range of operational
conditions. Kit supplied with
0, 1, and 10 NTU standards,
sample bottle, 4 sample
tubes, DPD tablets, and extra
battery.
Scattered Turbidity 90°
and Color Detector
Chlorine
Detector
Patent-pending
optical design
Turbidity Light
Source
Direct
Turbidity
Detector
IR LED 860nm: 3000i
Tungsten Lamp: 3000e
and stabilization detector
Chlorine LED 525nm
Color UV LED 370nm
and stabilization detector
and stabilization detector
Turbidity Specifications:
Unit of Measure NTU, FNU, FAU, ASBC, EBC
Range
0-4000
Resolution
0.01 NTU/FNU 0.00-10.99
0.1 NTU/FNU 11.00-109.9
1 NTU/FNU 110-4000
Accuracy
±2%
Range Selection Automatic
Detection Limit 0.05 NTU/FNU
Reproducibility
0.02 NTU/FNU, 0.5 FAU
Light Source
860nm LED (ISO) Tungsten (EPA)
Chlorine Specifications:
Range
Resolution
Accuracy
Detection Limit
Response Time
Light Source
0-10 ppm
0.01 ppm (0-5)
0.1 ppm (5-10)
0.02 or ±2%
0.02 ppm
<5 Seconds
525 nm LED
Color Specifications:
Range
Accuracy
Detection Limit
Light Source
Resolution
2-YEAR
WARRANTY
ULTRA
RUGGED,
WATERPROOF
CARRYING
CASE!
0-500 cu
±0.5 cu or 2%
0.2 cu
375 nm UV LED
0.1 cu (0-99.9 cu)
Meter Features:
Signal Averaging
Battery
AC Power
Data Logging
Auto Shut-Off
Optional Software
Languages
Response Time
5
Disabled, 2, 5, 10
9V
Optional
4000 points
Disabled, 5, 10, 30
SmartLink 2
English, French,
Spanish, Japanese,
Italian, Portuguese
<5 Seconds
t MSP430
Microcontroller used is the most advanced controller on the market for hand
held applications
t Advanced calibration algorithms
t Tube positioning ring limits tube variability
t Easy menu driven operation and large LCD display
t 4000 point data log, stored results can be viewed directly on instrument or downloaded
to a computer via RS-232 cable
2020 Turbidity Meters
2020e KiU t Order Code 1979-EPA
Turbidity complies with USEPA 180.1
Standard
2020i Kit t Order Code 1979-ISO
Turbidity complies with ISO 7027 Standard
2-YEAR
WARRANTY
Turbidity Specifications:
Unit of
Measure
Range
Resolution
NTU, FNU, FAU, ASBC,
EBC
0-4000
0.01 NTU/FNU 0.00-10.99
0.1 NTU/FNU 11.00-109.9
1 NTU/FNU 110-4000
±2%
0.05 NTU/FNU
Accuracy
Detection
Limit
Range
Automatic
Selection
Reproducibility 0.02 NTU/FNU, 0.5 FAU
Light Source
860nm LED (ISO)
Tungsten (EPA)
Meter Features:
Signal Averaging
Battery
AC Power
Data Logging
Auto Shut-Off
Optional Software
Languages
Response Time
Disabled, 2, 5, 10
9V
Optional
4000 points
Disabled, 5, 10, 30
SmartLink 2
English, French,
Spanish, Japanese,
Italian, Portuguese
<5 Seconds
ULTRA
RUGGED,
WATERPROOF
CARRYING
CASE!
Ideally suited for both
low-level drinking water
applications as well as
monitoring high turbidity
in the field.
2020e version meets USEPA design specifications for NPDWR and NPDES
turbidity monitoring programs as specified by USEPA method 180.1
2020i version meets design criteria for quantitative methods of turbidity using
optical turbidimeters as specified by ISO 7027.
Kits supplied with 0, 1, and 10 NTU standard, sample bottle, four sample
tubes, and an extra battery.
6
Kits and Accessories
TC-3000e Kit t Order Code 1964-EPA
Turbidity, Chlorine, and Color meter, turbidity complies
with USEPA 180.1 Standard
2020e Kit t Order Code 1979-EPA
Turbidity meter complies with USEPA 180.1 Standard
2020i KiU t Order Code 1979-ISO
Turbidity meter complies with ISO 7027 Standard
TC-3000i KiU t Order Code 1964-ISO
Turbidity, Chlorine, and Color meter, turbidity complies
with ISO 7027 Standard
1979-EPA
1979-ISO
1754
0641
0475
1480
1481
1482
1483
1484
1485
1486
6195-H
1964-EPA
1964-ISO
1754
0641
0475
1480
1481
1482
1483
1484
1485
1486
6195-H
TC-3000 Kit, EPA version
TC-3000 Kit, ISO version
AC adapter (variable 100-240V AC)
Vial Ring (2-pk)
Six pack of vials
0 NTU Standard (ISO and EPA), 60 mL
1 NTU Standard (ISO), 60 mL
10 NTU Standard (ISO), 60 mL
100 NTU Standard (ISO), 60 mL
1 NTU Standard (EPA), 60 mL
10 NTU Standard (EPA), 60 mL
100 NTU Standard (EPA), 60 mL
Formazin standard solution, 4000 NTU
(60 mL bottle)
4140
DPD Chlorine secondary standards kit
3176-01 FAS-DPD Titration kit for chlorine titration
6973-H
Standard chlorine solution, 250 ppm
(60 mL bottle)
6973-L
Standard chlorine solution, 250 ppm
(475 mL bottle)
3858-H
Permanganate solution, 1000 ppm
(60 mL bottle)
3858-L
Permanganate solution, 1000 ppm
(60 mL bottle)
6903A-J
Chlorine DPD #1 instrument grade tablets
(100 tablet box)
6197A-J
Chlorine DPD #3 instrument grade tablets
(100 tablet box)
P-6740-H* Liquid DPD 1A reagent (60 mL bottle)
P-6741-H* Liquid DPD 1B reagent (60 mL bottle)
P-6743-H* Liquid DPD 3 reagent (60 mL bottle)
*Note: DPD 1A and DPD 1B are both required to test
free residual chlorine and DPD1A, DPD1B and DPD 3
are required for testing total residual chlorine.
7
2020e Kit, EPA version
2020i Kit, ISO version
AC adapter (110V and 220V)
Vial Ring (2-pk)
Six pack of vials
0 NTU Standard (ISO and EPA), 60 mL
1 NTU Standard (ISO), 60 mL
10 NTU Standard (ISO), 60 mL
100 NTU Standard (ISO), 60 mL
1 NTU Standard (EPA), 60 mL
10 NTU Standard (EPA), 60 mL
100 NTU Standard (EPA), 60 mL
Formazin standard solution, 4000 NTU
(60 mL bottle)
HI 98703
EPA Compliant Turbidity Meter
FeaturesHANNA ’s Exclusive Fast Tracker™(T.I.S.)
EPA Compliant Turbidity
Measurement
The HI 98703 meets and exceeds the
requirements of the USEPA Method 180.1
for wastewater and Standard Method 2130
B for drinking water.
The HI 98703 measures the turbidity of a
sample in the 0.00 to 1000 NTU
(Nephelometric Turbidity Units) range. An
effective algorithm calculates and
converts the readings in NTU. The
instrument has an EPA compliance reading
mode which rounds the reading to meet
EPA reporting requirements. Depending on
the measured probe and needed accuracy,
normal, continuous, or signal averaging
measurement can be selected.
SPECIFICATIONS
HI 98703
Range
0.00 to 9.99; 10.0 to 99.9 and 100 to 1000 NTU
Range Selection
Automatic
0.01 NTU from 0.00 to 9.99 NTU; 0.1 NTU from 10.0 to 99.9 NTU;
1 NTU from 100 to 1000 NTU
Resolution
Accuracy
±2% of reading plus 0.02 NTU
Repeatability
±1% of reading or 0.02 NTU, whichever is greater
Stray Light
< 0.02 NTU
Typical EMC Deviation
±0.05 NTU
Light Detector
Silicon Photocell
Light Source
Tungsten filament lamp
Lamp life
Greater than 100,000 readings
Ratio Nephelometric Method (90°), ratio of scattered and transmitted light;
Adaptation of the USEPA Method 180.1 and Standard Method 2130 B.
Method
Measuring mode
Normal, Average, Continuous
Turbidity Standards
<0.1, 15, 100 and 750 NTU
Calibration
Two, three or four-point calibration
LOG Memory
200 records
Serial Interface
Environment
Up to 50°C (122°F); max 95% RH non-condensing
Power Supply
(4) 1.5V AA alkaline batteries or AC adapter; Auto-off after 15 minutes of non-use
224 x 87 x 77 mm (8.8 x 3.4 x 3.0”) / 512 g (18 oz.)
ORDERING INFORMATION
ACCESSORIES
HI 98703-01 (115V) and HI 98703-02 (230V)
are supplied with (5) sample cuvets and caps,
HI 98703-11 calibration cuvets, HI 93703-58
silicone oil, cuvet wiping tissue, (4) batteries, AC
adapter, instruction manual and rugged carrying
case.
HI 920005
Tag holders with tags (5)
HI 98703-58
Silicone oil (15 mL)
HI 731331
Glass cuvets (4)
SOLUTIONS
HI 92000
Windows® compatible software
HI 920011
5 to 9 pin RS232 connection cable
HI 920013
USB cable for PC connection
HI 98703-11
Turbidity standards kit
HI 93703-50 Cuvet cleaning solution, 250 mL
HI 98703 has a user-friendly interface
with a backlit, easy to read, large LCD
(Liquid Crystal Display). The display codes
guide the user step by step with routine
operation and through calibration.
With it’s logging function, up to 200
measurements can be stored in the
internal memory and consulted at any
time. In order to further store and analyze,
the data can be downloaded to a PC using
by either RS232 or USB.
For advanced field applications, the
HI 98703 turbidimeter is equipped with
Fast Tracker™—Tag Identification System
(T.I.S.) that makes data collecting and
management simpler than ever.
t Tungsten light source—EPA
compliant turbidity measurement
USB or RS 232
Dimensions / Weight
HI 98703 has GLP (Good Laboratory
Practice) functions that allow traceability
of the calibration conditions. The last
calibration points, time and date can be
checked at any time by a single touch.
HI 93703-60
Caps for cuvets (4)
HI 731318
Tissue for wiping cuvets (4)
8
t High accuracy at low ranges
(below 0.05 NTU)
Exclusive Fast Tracker™
t 2, 3 or 4 point calibration
t USB and RS232 PC connectivity
t Backlit LCD
t GLP capability
t User friendly display with
guidance codes
t Battery percentage on display
t Continuous current time on display
t
ANALITE NEP160 TURBIDITY METER
for Field and Laboratory Applications
The ANALITE NEP160 is a truly portable turbidity meter. Readings are taken by simply inserting the probe into
the steam or media to get an immediate result truly representative of the turbidity level at that point and time.
It allows for easy and fast multiple readings at a site to ascertain the real turbidity profi le of a stream or water
body.
The ANALITE 160 turbidity meter allows the user to set up measurement parameters through a user-friendly
menu system displayed on the in-built 2 line alphanumeric display.
All ANALITE NEP160 compliant probes are “hot swappable” and contain their calibration data in the probe
proper thereby avaoiding the need to calibrate every time another probe is connected. The NEP160 (and its
probes) comes supplied precalibrated however the user can calibrate a probe at any time using the simple
menu driven interface. Both 2 and 3 point calibrations can be preformed.
The NEP160 comes complete in a convenient carry case. The carry case can accommodate a probe with a
cable length of up to 10 meters, an ac adapter, the display unit, the RS232 cabling and the User Manual.
Specifi cations:
Range:
0 to 30,000NTU (3,000NTU limit on
NEP260, 90° probe) over four ranges
automatically determined.
2 line, 16-character dot matrix
Display:
alphanumeric liquid crystal display.
Turbidity (NTU) - default
Displayed:
Relative Turbidity Reference (NTU)
Relative Turbidity REL (Turbidity - Relative
Turbidity Reference)
Date/Time - default
Updated approximately every 1 second.
Reading:
Averaging period: 0.5 second or 8 seconds nominal – user
selectable.
1 <0.1 to 20NTU
Range Steps:
2 <1 to 200NTU
3 <10 to 2,000NTU
4 <100 to 20,000NTU
1 0.02NTU
Resolution
2 0.1NTU
3 1NTU
4 10NTU
2% ± 1 digit on all ranges.
Repeatability:
User set for one reading every 1 to 90
Data Logging:
seconds or minutes. All readings stored in
the Notepad.
100 readings each with time and date.
Notepad:
Menu driven, including:
Setup :
– Calibration
– Automatic Logging
– Analogue Output range selection
– Reference Turbidity value
– Setting date and time.
Setup Memory: Non volatile EEPROM.
Calendar clock displays date and time.
Clock:
Good Laboratory Practice. All readings as
GLP:
well as calibration constants are stored
together with the Time and Date and can
be recalled at any time.
Analogue Output: 0 – 2 volts full scale corresponding to preset
measurement range.
Output impedance 600 ohms nominal.
Internal: 6V NiMH rechargeable battery.
Power:
External: 10 to 16V dc, 400mA max.
incl. NiMH Charge current. External power
connection is via jack plug male with 2.5mm
pin. Centre pin is NEGATIVE polarity.
9
Outputs:
Inbuilt LCD, analogue output and RS232
port.
The RS232 port can output readings on
RS232 Port :
request or at preset intervals of time from
1 to 99 seconds or minutes. The Notepad
memory can also be downloaded on
request.
4800 baud rate, 8 bits, no parity, 1 stop bit,
Xon/Xoff protocol.
187mm x 110mm x 51mm (display unit).
Dimensions:
238mm x 32mm dia (probes incl gland).
Display Unit
0.5kg.
Weight:
180° Probe
0.4kg with 5m lead.
90° Probe
0.4kg with 5m lead.
Operating
Operating Temp’: 0° to 50°C.
-10° to 60°C
Storage
0 to 90% R.H. operating
Humidity:
IP65 with all connectors sealed with
Case Rating:
dust caps (supplied) or probe properly
connected and dust caps on remaining two
connectors.
100 meters water column.
Probe Rating:
Ordering Info:
NEP160-1-05R NEP160 with NEP280 - 180° general
purpose probe.
NEP160-2-05R NEP160 with NEP285 - 180° hi-temp
probe.
NEP160-3-05R NEP160 with NEP260 - ISO7027 90°
probe.
Display unit only.
NEP160R
All probes are supplied with 5 meters of
cable unless otherwise indicated at time of
order.
DataBank
Handheld Datalogger
DataBank Handheld Datalogger
Highlights of the DataBank
The DataBank is a universal handheld meter, datalogger,
t Stores up to 9,999 records and 16 calibrations
and power supply. Designed to work with analog sensors
from various manufacturers, the DataBank is easy to
t Includes auto-gain function
connect and use. Data, including GPS information, can
t Enables unattended datalogging at intervals
from 1 second to 4 days
be stored and downloaded to a PC. Sensor calibration is
simpli
d through continuous sensor readings with
results graphically displayed. Sensor power is provided
t Simpli
directly from the DataBank, eliminating the need to
t Provides rugged, weather-proof design
connect external batteries. Designed with the customer
in mind, the DataBank allows one-handed operation
t GPS-enabled
– even while wearing gloves.
DataBank Electrical Spe
Selectable Sensor
Parameters
Inputs
t Works with many analog sensors including
Seapoint Sensors, WET Labs and Campbell
Scien c
cations
Voltage: Software selectable 3 to 12 volts
Current: 150 mA at 3V to 100 mA at 12V
Warm-up Time: 0-25 seconds
Gain: 1-4
Ordering Information
INSTRUMENT
Input Selection: Switch; D
rential Voltage, D rential Current or
Dual Current
Range: 0-5V or 0-25 mA
Resolution: 12 bits
Sampling Rate: 1000 Hz (bursts); groups of bursts re-averaged @
30 Hz
Outputs
Two, Open Drain, up to 200 mA @ 15V max
(Used primarily for gain selection)
Storage
Non-Volatile, 1280 Kb
(9,999 records, 1 record = sensor reading, date, time and location)
Current Draw
Computer: <=45 mA (at full charge). Sleeping <20 uA LCD
Backlight: Full power ~ 30 mA. Low Power ~ 15 mA
Battery
Type: NiMH rechargable, 4.8 volts, 4,000 mA/Hr. User-replaceable
Life: Continuous up to 70 hours (dependant on sensor)
Charge Time
~3 hours (for a fully discharged battery; ambient @ 25 degrees C)
Serial Communications
RS-232
GPS Power
3.3 VDC @ up to 300 mA
Note: While DataBank is o , GPS is self-powered
DataBank Physical S
or calibration
cations
Size
Main body: 4.6”W x 3.2”H, x 3.4”D, Handle: 4.8” long
Overall: 11”H (with handle, stain-relief and connector).
Weight
1.7 lb. (.76 kg) w/o GPS
Weatherproof
Case IP65, connector IP68, buttons IP64.
10
PART NUMBER
All instrument packages include rechargeable NiMH
batteries, PC/Power interface cable, AC to DC charger
supply, software & manual
DataBank Handheld Datalogger
2900-000
For use with many analog sensors
DataBank Handheld Datalogger
with 2ft Cyclops Interface Cable
2900-002
DataBank Handheld Datalogger
with 5m Cyclops Interface Cable
2900-005
DataBank Handheld Datalogger
with 10m Cyclops Interface Cable
2900-010
DataBank Handheld Datalogger
with 25m Cyclops Interface Cable
2900-025
DataBank Handheld Datalogger
with 50m Cyclops Interface Cable
2900-050
DATABANK ACCESSORIES
PART NUMBER
Travel Case
142-2900
GPS Mounting Bracket for Garmin eTrex 2900-400
GPS Mounting Bracket for Garmin Geko 2900-401
External Power Option
2900-940
Car Charger
2900-151
F LEXIBLE P HOTOMETERS
FOR L AB OR
F IELD
YSI’s new line of photometers includes the Model 9300 and
9500. Eliminate sample preservation by taking your portable,
site. All reagents are safe and easy to use.
Selecting the desired test has never been easier. Simply navigate
among the list of available tests on the screen of the instruments
you through the steps to complete the test. Simple. Convenient.
Accurate.
Features (Model 9300 and 9500):
t %Jrect-reading concentrations with automatic set up
The YSI 9500.
Applications include:
t
t
t
t
t
t
Aquaculture
Aquarium management
Surface water
Education
Wastewater
Watershed management
t Large backlit graphic display
t Unique sample tube holder accommodates various diameters
t On-screen instructions
t Multiple languages (English, French, German, Spanish, Italian)
t 100+ test choices on the photometer display
Additional Features (Model 9500 only):
t Waterproof USB connection
t Power via USB port
t Internal MemorZ - 500 sample sets
t User-Selectable Options: test units, sample number, dilution factors
Advanced
recent tests, making it even quicker to use the next time. Up to 500 test
results are held in the 9500’s memory along with a date and time stamp.
-
Specifications
Accuracy
Resolution
Operating Wavelengths
Display
Power
Size (WxLxH)
Weight
Test Cells
±0.5% aU 4% transmittance; ±0.005 aU 0.3 AU
0.001 AU
450, 500, 550, 575, 600 anE 650 nm
Graphic, backlit L$% with on-screen instructions
3Y "" batteries; thF 9500 can also be powered via USB
146 Y 275 Y 75 mN (5.8 Y 10.8 Y 3 Jnches)
975 H (2 lbs)
Automatic adjustment froN 12-20 mm diameter
11
Ordering
Test Kits
Range
Starter Packs
(50 Tests)
Replacement Packs
(250 Tests)
Alkalinity, Total (Alkaphot)
Alkalinity-M (Alkaphot M)
Alkalinity-P (Alkaphot P)
Aluminum
Ammonia
Boron
Bromine
Calcium Hardness (Calcicol)
Chloride (Chloridol)
Chlorine DPD 1
Chlorine DPD 2
Chlorine DPD 1&3
Chlorine DPD 4
Chlorine HR (High Range)
Chlorine Dioxide (DPD)
0-500 (CaCO3 )
0-500 (CaCO3 )
0-500 (CaCO3 )
0-0.5
0-1.0 (N)
0-2.5
0-10.0
0-500 (CaCO3 )
0-50,000 (NaCl)
0-5.0
0-5.0
0-5.0
0-5.0
0-250
0-4.0
YPM188
YPM250
YPM251
YPM166
YPM152
YPM190
YPM060
YPM252
YPM268
YPM011
YPM021
YPM031
YPM041
YPM162
YPM052
YAP188
YAP250
YAP251
YAP166
YAP152
YAP190
YAP060
YAP252
YAP268
YAP011
YAP021
YAP031
YAP041
YAP162
YAP052
Chlorine Dioxide LR (Low Range)
Chlorine Dioxide HR (High Range)
Chromium VI (Hexavalent)
Copper (Coppercol) (free,
combined, total)
Copper (free)
Color (includes turbidity)
Cyanuric Acid
Fluoride
Hardness (Hardicol)
Hydrazine
0-2.5
2.5-20
0-1.0
0-5.0
YPM064
YPM065
YPM281
YPM186
YAP064
YAP065
YAP281
YAP186
0-5.0
10-500
0-200
0-1.5
0-500 (CaCO3 )
0-0.5
N/A
YPM269
YPM087
YPM179
YPM254
YPM103*
YAP187
N/A
YAP087
YAP179
YAP254
YAP103
Hydrogen Peroxide LR
Hydrogen Peroxide HR
Iron LR
Iron MR
Iron HR
Magnesium (Magnecol)
Manganese
Molybdate LR
Molybdate HR
Nickel
0-2
0-100
0-1.0
0-5.0
0-10
0-100
0-0.03
0-20
0-100
0-10
YPM104
YPM105
YPM155
YPM292
YPM156
YPM193
YPM173
YPM258
YPM175
YPM284
YAP104
YAP105
YAP155
YAP292
YAP156
YAP193
YAP173
YAP258
YAP175
YAP284
Nitrate
Nitrite (N)
Nitrite (NaNo 2 )
Organophosphonate (OP)
Ozone
pH (phenol red)
Phenol
Phosphate LR
Phosphate HR
Potassium
0-20 (N)
0-0.5 (N)
0-1500 (NaNo2 )
0-20 (PO4 )
0-2.0
6.8-8.4
0-5.0
0-4.0
0-100
0-12
YPM163
YPM109
YPM260
YPM262
YPM056
YPM130
YPM287
YPM177
YPM114
YPM189
YAP163
YAP109
YAP260
YAP262
YAP056
YAP130
YAP287
YAP177
YAP114
YAP189
Silica
Silica HR
Sulphate
Sulphide
Sulphite
Zinc
0-4.0
0-150
0-200
0-0.5
0-500 (Na2 SO 3 )
0-4.0
YPM181
YPM290
YPM154
YPM168
YPM266
YPM148
YAP181
YAP290
YAP154
YAP168
YAP266
YAP148
Item
Part Number
Description
9300
9500
285
286
804
283
284
YPT9300
YPT9500
YPT285
YPT286
YPT804
YPT283
YPT284
9300 photometer**
9500 photometer***
Hard-sided carrying case for the 9300
Hard-sided carrying case for the 9500
Color Standard Kit
USB Power Supply for 9500
USB Waterproof Cable for 9500
* Includes 30 tests ** Includes YPT285 *** Includes YPT286 and YPT284
12
SINGLE WAVELENGTH COLORIMETERS
1200 COLORIMETER SERIES
The new 1200 Series of single test, direct reading colorimeters incorporates design advances that enhance
reliability, improve accuracy, and simplify the calibration process, all in a portable, hand-held package.
SPECIFICATIONS:
Instrument Type:
Readout:
Photometric Accuracy:
Detector:
Sample Chamber:
Light Source:
Interface:
Power:
Size (LxWxH):
Single wavelength, direct-reading colorimeter
3½digit LCD
±0.001 Absorbance Unit
Silicon Photodiode
Accepts 25mm diameter flat-bottom, capped test tubes (included)
LED
RS-232 serial interface
Alkaline 9-volt DC battery, 3.5 mm jack for optional AC adapter
15 x 8 x 5.5 cm; 6 x 3c x 2½inches
SINGLE TEST COLORIMETER KITS AVAILABLE:
Test Factor
Ammonia Nitrogen
Bromine
Chlorine (Free &
Total) SEE BELOW
Chlorine (Free &
Total) SEE BELOW
Order
Code
3680-01
3672-01
DC1200-NH
DC1200-BR
Range
(ppm)
0–5.0
0–7.0
Detection
Limit
0.05
0.05
3670-01
DC1200-CL
0–4.0
0.05
DPD Tablets (2)
3670-01- DC1200-CLLI
LI
0–4.0
0.05
DPD Liquid (3)
0–7.0
0.05
Model
Chlorine Dioxide
3671-01 DC1200-CLO
Copper
3673-01
DC1200-CO
0–8.0
0.03
Fluoride
Iron
Manganese
Molybdenum
Nitrate Nitrogen
Ozone
Phosphate
Sulfate
3674-01 DC1200-FL
3681-01 DC1200-FE
3682-01 DC1200-MN
3676-01 DC1200-MO
3677-01 DC1200-NA
3678-01 DC1200-OZ
3679-01 DC1200-PLR
3683-01 DC1200-SU
0–2.0
0–4.0
0–0.9
0–50
0–3.0
0–0.4
0–3.0
0–100
0.028
0.25
0.01
0.5
0.05
0.04
0.07
1.0
13
Test Method (# of
Reagents)
Nessler (2)
DPD Tablets (1)
DPD with Glycine
Solution (2)
Diethyldithiocarbamate
(1)
Alizarin-Zirconyl (2)
1–10 Phenanthroline (2)
PAN (3)
Thioglycolate (3)
Cadmium Reduction (2)
Indigo Blue (3)
Ascorbic Acid (2)
Barium Chloride (1)
SMART SpectroTM Spectrophotometer
The SMART Spectro is a portable spectrophotometer that is easier to use and more accurate
than anything in its price range. With automatic wavelength selection, pre-programmed
tests, and superior performance - this is the best spectrophotometer for the money!
Over 80 pre-programmed tests included, and 25 user calibrations can be entered into the
memory. The user can also customize sequences for frequently run tests.
Advanced Features:
•
•
•
•
•
•
A wider wavelength range
Menu-driven display
Pre-programmed tests with 25 user tests
Automatic wavelength selection
Unique optical design system using a 1200 lines/mm grating
Greater accuracy, higher resolution
All Ready to Go!
The SMART Spectro is supplied
with 6 sample tubes, 2 sample
cell holders, AC adapter, battery
charger, instruction manual
including test procedures, and
quick-start guides.
Specifications:
Wavelength Range:
350-1000 nm
Wavelength Accuracy:
±2 nm
Wavelength Resolution:
1 nm
Wavelength Bandwidth:
Photometric Range:
Photometric Accuracy:
Photometric Noice:
Photometric Drift:
Photometric Stray Light:
Dispersive Device:
Optical Mount:
5 nm (max)
0-125%T, -0.1-2.5A
±0.005A
<0.001A at 0A,<0.002A at 2A
±0.002A/hr @500 nm
<0.5 %T
Grating - based system
Modified Ebert
Grating:
1200 grooves/mm ruled grating
Light Source:
Quartz halogen
Bulb Life:
Sample Chambers:
1000 hours minimum
25 mm round cell, 10 mm square cuvette UDV, COD, flow-through (optional)
Detector:
Silicon photodiode
Temperature Range:
0-40°C
Modes
Pre-Programmed Tests:
Wavelength Selection:
User Tests:
Conc., %T, ABS
Yes
Automatic
Yes, up to 25 can be entered and edited
Datalogging:
Yes, RS-232
Diagnostics:
Yes
Power:
Weight:
Size (W x D x H):
110/220 volt or battery pack (rechargeable)
4.65 kgs (10.3 lbs)
35 cm x 28 cm x 17 cm
14
SMART Spectro Reagent Systems
Test Factor
Alkalinity UDV†
Range ppm
0-200
# of
Tests
Case
Size*
Order Code
UDV (1)
50
E
4318-H
Test Method (# of reagents)
Aluminum
0.00-0.30
Eriochrome Cyanine R (4)
50
C
3641-SC
Ammonia Nitrogen-LR (Fresh Water)
0.00-1.00
Salicylate (3)
25
A
3659-01SC
Ammonia Nitrogen-LR (Salt Water)
0.00-1.00
Salicylate (3)
25
A
3659-01SC
Ammonia Nitrogen HR
0.00-4.00
Nesslerization (2)
50
A
3642-SC
Benzotriazole
0.00-30.00
UV Oxidation/Dichromate
50
C
4047
Biquanide
0.00-70.00
Colorimetric
50
A
4044
50
D
4868
100
A
3643-SC
Boron
0.00-0.80
Azomethine-H (2)
Bromine LR
0.00-9.00
DPD Tablets (3)
Bromine UDV†
0.00-22.00
Unit Dose Vial (1)
50
E
4311-H
Cadmium
0.00-1.00
PAN (4)
50
E
4017
Calcium/Magnesium (Total) Hardness
UDV
10-500
Unit Dose Vial (1)
50
Carbohydrazide
0.0000.9000
Iron Reduction (3)
100
E
4857
Chloride TesTab
0.0-30.0
Argentometric (1)
50
A
3693-SC
100
A
3643-SC
Chlorine
0.00-4.00
DPD Tablets (3)
4309-H
Chlorine Free UDV†
0.00-10.00
DPD (1)
50
E
4311-H
Chlorine Liquid DPD
0.00-4.00
DPD (3)
144
A
4859
Chlorine Total UDV†
0.00-10.00
DPD (1)
50
E
4312-H
50
A
3644-SC
Chlorine Dioxide
0.00-7.00
DPD tablet/Glycine (2)
Chromium (Hexavalent)
0.00-1.00
Diphenylcarbohydrazide (1)
100
A
3645-SC
Chromium TesTab
0.00-1.00
Diphenylcarbohydrazide (1)
50
A
3697-SC
Chromium (Total, Hex & Trivalent)
0.00-1.00
Diphenylcarbohydrazide (5)
100
D
3698-SC
Cobalt
0.00-2.00
PAN (3)
50
D
4851
COD LR 0-150 with Mercury‡
5-150
Digestion (1)
25
D
0075-SC
COD LR 0-150 without Mercury‡
5-150
Digestion (1)
25
D
0072-SC
COD SR 0-1500 with Mercury‡
0-1500
Digestion (1)
25
D
0076-SC
COD SR 0-1500 without Mercury‡
0-1500
Digestion (1)
25
D
0073-SC
15
COD HR 0-15,000 with Mercury‡
0-15,000
Digestion (1)
25
D
0077-SC
COD HR 0-15,000 without Mercury‡
0-15,000
Digestion (1)
25
D
0074-SC
¥
—
NA
50
A
3640-SC
Color
Copper BCA - LR
0-1000
0.00-3.50
Platinum Cobalt (0)
Bicinchoninic Acid (1)
Copper Cuprizone
0.00-2.00
Cuprizone (2)
50
A
4023
Copper DDC
0.00-6.00
Diethyldithiocarbamate (1)
100
A
3646-SC
Copper UDV†
0.00-4.00
UDV, Bicinchoninic acid (1)
50
E
4314-H
Cyanide
0.00-0.50
Pyridine-Barbituric Acid (5)
50
C
3660-SC
100
C
3661-SC
50
E
4313-H
100
A
4857
Winkler Colorimetric (3)
100
A
3688-SC
100
A
4857
Cyanuric Acid
5-200
Melamine (1)
Cyanuric Acid UDV†
5-150
Melamine, UDV (1)
DEHA
Dissolved Oxygen (DO)
0.000-0.700 Iron Reduction (3)
0.0-12.0
Erythorbic Acid
0.00-3.00
Iron Reduction (3)
Fluoride
0.00-2.00
SPADNS (2)
50
B
3647-01SC
UDV
50
E
4309-H
25
A
3656-SC
Hardness (total) UDV
10-500
Hydrazine
0.00-0.75
pdimethylaminobenzaldehyde
(2)
Hydrogen Peroxide LR
0.00-1.50
DPD Tablets (2)
100
A
3662-SC
Hydrogen Peroxide HR
0.00-60.00
DPD
100
B
4045
0.00-225.00 DPD
100
B
4045
Iron Reduction (3)
100
A
4857
DPD Tablets (2)
100
A
3643-SC
Bipyridyl (2)
50
A
3648-SC
Bipyridyl UDV (1)
50
E
4315-H
Hydrogen Peroxide Shock
Hydroquinone
Iodine
Iron
Iron UDV†
0.00-1.80
0.00-14.00
0.00-6.00
0.00-10.00
Iron Phenanthroline
0.00-4.50
1,10 Phenanthroline (2)
50
A
3668-SC
Lead
0.00-5.00
PAR (5)
50
D
4031
Manganese LR
0.00-0.70
PAN (3)
50
B
3658-SC
Manganese HR
0.0-15.0
Periodate (2)
50
A
3669-SC
50
D
4861
100
A
4857
Thioglycolate (3)
50
B
3699-02SC
Mercury
0.00-1.50
TMK (3)
Methylethylketoxime
0.00-3.00
Iron Reduction (3)
Molybdenum HR
0.0-15.0
Nickel
0.00-8.00
Dimethylglyoxime (6)
50
D
3663-SC
Nitrate Nitrogen LR
0.00-3.00
Cadmium Reduction (2)
20
A
3649-SC
Zinc Reduction (1)
50
A
3689-SC
Nitrate TesTab
0.0-60.0
Nitrite Nitrogen LR
0.00-0.80
Diazotization (2)
20
A
3650-SC
Nitrite TesTab
0.00-1.25
Diazotization (1)
50
A
3886-SC
0.00-25.00
Chromotropic Acid and
Perfulfate Digestion
25
D
4026
Ozone LR
0.00-0.40
Indigo Trisulfonate (3)
100
D
3651-SC
Ozone HR
0.00-2.50
Indigo Trisulfonate (3)
20
D
3651-SC
Nitrogen, Total‡
16
pH CPR (Chlorphenol Red)
5.0-7.0
Colorimetric (3)
100
B
3700-SC
pH PR (Phenol Red)
6.6-8.4
Colorimetric (3)
100
B
3700-SC
pH TB (Thymol Blue)
8.0-9.5
Colorimetric (3)
100
B
3700-SC
Phenol
0.00-6.00
4-Aminoantipyrine (3)
50
B
3652-SC
Phosphate LR‡
0.00-3.00
Ascorbic Acid Reduction (2)
50
A
3653-SC
Phosphate HR‡
0.00-70.0
Vanadomolybdophosphoric
Acid (1)
50
A
3655-SC
Phosphorus, Total LR
0.00-3.50
Ascorbic Acid and Persulfate
Digestion
25
D
4024
Phosphorus, Total HR
0.00-100.00
Molybdoranadate and
Persulfate Digestion
25
D
4025
0.0-10.0
Tetraphenylboron (2)
100
A
3639-SC
Potassium
Silica LR
0.00-2.50
Heteropoly Blue (4)
50
A
3664-SC
Silica HR
0-50
Silicomolybdate (3)
50
A
3687-SC
5.00-100.00 Barium Chloride (1)
50
A
3665-SC
Sulfate
Sulfide LR
0.00-1.00
Methylene Blue (3)
50
B
3654-01SC
Surfactants
0.00-8.00
Bromphenol Blue (3)
50
D
4876
Tannin
0.00-10.00
Tungstomolybdophosphoric
Acid (2)
50
B
3666-SC
Tolytrizole
0.00-30.00
UV Oxidation/Dichromate
50
C
4047
¥
—
NA
50
D
3667-SC
Turbidity
Zinc LR
0-400
0.00-3.00
Absorptimetric (0)
Zincon (6)
†Requires Accessory Package Code Number 1961 or 1962.
‡Requires Heater Block.
*Case Type:
A: 7 x 7 x 10 cm
B: 14.5 x 6.5 x 13 cm
C: 14.5 x 9.5 x 13.5 cm
D: Stand-alone cases. Will not fit into optional field carrying cases.
E: 13 x 7 x 12.5 cm
17
SPECIFICATIONS
YSI ProDSS Multiparameter Sampling Instrument
Portable digital sampling system for the measurement of pH, ORP,
dissolved oxygen (optical-based sensor), conductivity, turbidity, temperature, depth and more.
Designed for use in applications such as surface water, groundwater,
coastal waters, and aquaculture, the rugged and reliable ProDSS allows
for measurement of up to 17 parameters. The ProDSS features userreplaceable digital smart sensors that are automatically recognized by
the instrument when connected. A backlit color display, large memory,
convenient calibration procedures, rechargeable battery, and powerful PC
data management program (KorDSS) make the ProDSS user friendly. The
optional GPS function, wide range of sensors, and varying cable lengths
allow for complete customization of the ProDSS. Mil-spec (military spec)
connectors and a waterproof (IP-67), rubber over-molded case ensures
durability to provide years of sampling even in the harshest field conditions.
• Single cable design features universal ports which can accept any 4
sensors plus depth
• Long-life rechargeable lithium-ion battery to power handheld and sensors
• Color display and backlit keypad allow for sampling in all lighting
conditions
• Digital smart sensors are automatically recognized by the instrument and
store calibration data
• User-replaceable cables and sensors provide versatility, reduce down time
and reduce overall cost of ownership
• Large memory (> 100,000 data sets) with extensive site list and Data ID tag
Parameters:
Dissolved Oxygen (Optical)
Turbidity
pH
ORP/Redox
Conductivity
Specific Conductance
Salinity
Total Dissolved Solids (TDS)
Resistivity
Seawater Density
Total Suspended Solids (TSS)
Depth
Ammonium
Ammonia
Chloride
Nitrate
Temperature
capabilities
• KorDSS, a powerful data management software with geo-mapping
capability, is included with the instrument
• USB On-The-Go connector for PC connection, recharging/powering the
ProDSS and connecting directly to a USB stick
• Global Positioning System (GPS) (optional)
• Cable lengths up to 100 meters available with or without a depth sensor
• Rugged, waterproof case (IP-67 rated) with rubber over-mold and metal,
military-spec (MS) cable connectors as well as rugged titanium sensors
• Multiple languages in handheld and KorDSS: English, Spanish, Portuguese,
French, German, Italian, Japanese, Norwegian, and Chinese (simplified and
traditional)
• Warranty: 3-year instrument; 2-year cable assembly and sensors; 1-year pH
and pH/ORP sensor modules; 6-months ammonium, nitrate and chloride
sensor modules.
18
ProDSS General Specifications
Size
8.3 cm width x 21.6 cm length x 5.6 cm depth (3.25 in. x 8.5 in. x 2.21 in.)
Weight with batteries
567 grams (1.25 lbs)
Power
Rechargeable lithium-ion battery pack providing ~48 hours of battery life (instrument only with backlight off)
Instrument operating temperature
0 to 50 °C (32 to 122 °F)
Instrument storage temperature
0 to 45 °C (32 to 113 °F) with battery installed; 0 to 60 °C (32 to 140 °F) without battery installed
Display
Color, LCD graphic display
USB port
Built-in micro USB On-The-Go port for PC connection, recharging/powering the ProDSS and connecting directly to a USB stick
Cables
Available with or without depth sensor in 1, 4, 10, 20, 30, 40, 50, 60, 70, 80, 90, and 100-meters
Sensor ports
4 universal sensor ports on each cable; can accept any ProDSS sensor
Warranty
3-year instrument; 2-year bulkhead, cable assembly, and sensors; 1-year pH and pH/ORP sensor modules, ODO sensor caps, and Li-ion
battery pack; 6-months ammonium, nitrate, and chloride sensor modules
Memory
> 100000 data sets
Logging modes
Single point or continuous with autostable feature
GLP compliance
Yes; 400 detailed GLP records can be stored and are available to view, download, and print.
Languages
English, Spanish, Portuguese, French, German, Italian, Japanese, Norwegian, Simplified Chinese, Traditional Chinese
Certifications
CE; RoHS; IP-67; WEEE; FCC; UN Part III, Section 38.3, Test methods for lithium-ion batteries (Class 9)
GPS
Optional internal GPS; coordinates are stored with measurement data and site lists
Sites and data ID
100 user-defined sites and 100 user-defined data ID tags
ProDSS System Specifications (Instrument, Sensor, and Cable)
Sensor/Parameter
Range
Accuracy
Resolution
Units
Temperature
-5 to 70 °C (temperature compensation range ±0.2 °C
for DO mg/L measurement: -5 to 50 °C )
0.1 °C or 0.1 °F (user
selectable)
pH
0 to 14 pH units
±0.2 pH units
0.01 pH units
ORP
-1999 to 1999 mV
±20 mV
0.1 mV
Dissolved
Oxygen
0 to 500%, 0 to 50 mg/L
0 to 200%: ±1% of reading or 1% saturation, whichever is
greater
200 to 500%: ±8% of reading
0.01 mg/L and 0.1%, o r % saturation, % saturati on
0.1 mg/L and 1% (user local, mg/L, ppm
selectable)
°C, °F, K
pH, pH mV
mV
0 to 20 mg/L: ±0.1 mg/L or 1% of reading, whichever is greater
20 to 50 mg/L: ±8% of reading
Barometer
375 to 825 mmHg
±1.5 mmHg from 0 to 50 °C
0.1 mmHg
Conductivity
0 to 200 mS/cm
0 - 100 mS/cm: ±0.5% of reading or .001 mS/cm, whichever
is greater
100 - 200 mS/cm: ±1.0% of reading
0.001, 0.01 or 0.1 μS/
cm (range dependent )
Specific Conductance * 0 to 200 mS/cm
0 - 100 mS/cm: ±0.5% of reading or .001 mS/cm, whichever
is greater
mmHg, inHg, mbar, psi,
kPa, atm
100 - 200 mS/cm: ±1.0% of reading.
User selectable reference temperature (15 to 25 °C; default 25
�C) and compensation coeffcient (0 to 4%/�C; default 1.91%)
Salinity*
0 to 70 ppt
±1.0% of reading or ±0.1 ppt, whichever is greater
0.01 ppt
ppt or PSU
Total Dissolved Solids 0 to 100 g/L
(TDS)*
Calculated from specifc conductance and a user-selectable TDS 0.001, 0.01, 0.1 g/L
multiplier (0.30 to 1.00; default 0.65)
Resistivity*
0 to 2 Mohms
±0.1% Full Scale
0.001, 0.01, 0.1 ohms
Seawater Density*
0.0 to 50.0 sigma, sigma T
-
0.1 sigma or sigma T Sigma, Sigma T
Turbidity
0 to 4000 FNU
0 to 999 FNU: 0.3 FNU or ±2% of reading, whichever is greater
0.1 FNU
FNU, NTU
User correlated from turbidity feld measurements and lab TSS
measurements from grab samples
0.01, 0.1 mg/L
mg/L
mg/L, g/L, kg/L
ohm-cm, kohm-cm,
Mohm-cm
1000 to 4000 FNU: ±5% of reading
Total Suspended Solid s0 to 30000 mg/L
(TSS)*
Ammonium**
0 to 200 mg/L NH -N
4
±10% of reading or 2 mg/L, whichever is greater
0.01 mg/L
NH -N mg/L, NH -N mV
Ammonia*
0 to 200 mg/L NH -N
3
-
0.01 mg/L
NH3-N mg/L
Chloride**
0 to 18000 mg/L Cl
±15% of reading or 5 mg/L, whichever is greater
0.01 mg/L
Cl mg/L, Cl mV
Nitrate**
0 to 200 mg/L NO -N
±10% of reading or 2 mg/L, whichever is greater
0.01 mg/L
NO-N mg/L, NO -N mV
Depth
0 to 328 feet (0 to 100 m)
±0.013 ft (±0.004 m) for 1, 4, and 10 m cables
0.001 m or 0.01 ft
m, ft
3
±0.13 ft (±0.04 m) for cables 20 m and longer
*Derived/calculated parameter **ISEs for freshwater only; 20 meter maximum depth
19
4
3
4
3
ProDSS System Specifications (Instrument, Sensor, and Cable)
Sensor/Parameter
Sensor Type/Measurement Method
Calibration
Maximum Depth
Warranty
Temperature
Thermistor, installed on conductivity sensor
Not available
100 m
2 years for conductivity/temperatur e
sensor
pH
Combination glass bulb electrode,
Ag/AgCl reference electrode with gelled electrolyte
1, 2, or 3 point
100 m
2 years for pH and pH/ORP sensors
ORP
Platinum button with Ag/AgCl reference
1 point
100 m
2 years for pH/ORP sensor
Dissolved
Oxygen
Optical luminescence - lifetime method
1 or 2 point
100 m
2 years for optical DO sensor
Barometer
-
1 point
-
3 years, integrated into ProDSS handheld
Conductivity
Four nickel electrode cell
1 point
100 m
2 years for conductivity/temperatur e
sensor
Specific Conductance*Calculated from conductivity and temperature
1 point
-
-
Calculated from conductivity and temperature
1 point
-
-
Total Dissolved Solids Calculated from specifc conductance and a userselectable TDS multiplier (0.30 to 1.00; default
(TDS)*
0.65)
-
-
-
Resistivity*
Calculated from conductivity and temperature
-
-
-
Seawater Density*
Sigma is calculated from salinity, temperature, and
pressure (depth)
Sigma T is calculated from salinity and temperature
-
-
-
Turbidity
Nephelometric - Optical, 90° scatter
1, 2, or 3 point
-
2 years for turbidity sensor
Total Suspended Solids User correlated from turbidity feld measurements
and lab TSS measurements from grab samples
(TSS)*
-
-
-
Ammonium**
Ion selective electrode
1, 2, or 3 point
20 m
2 years for ammonium sensor
Ammonia*
Calculated from ammonium, temperature, salinity,
and pH
-
-
-
Chloride**
Ion selective electrode
1, 2, or 3 point
20 m
2 years for chloride sensor
Nitrate**
Ion selective electrode
1, 2, or 3 point
20 m
2 years for nitrate sensor
1 year for pH and pH/ORP sensor
modules
1 year for pH/ORP sensor module
Salinity*
1 year for optical DO sensor cap
6 months for ammonium sensor module
6 months for chloride sensor module
6 months for nitrate sensor module
Depth
Pressure transducer
-
1 point
*Derived/calculated parameter
**ISEs for freshwater only ; 20 meter maximum depth
20
2 years, integrated into cable assembly
Digital Optical Dissolved Oxygen Meter
YSI ODO ® technology reduces the time required calibrating
and maintaining sensors while utilizing a user replaceable
sensing element that requires approximately an annual
replacement. There are no electrodes to clean or solutions
to change. Based on usage, calibrations can be stable for
up to one year and are stored in each sensor.
Expanded DO range of 0-500% with a response time
of T90 in approximately 25 seconds
Non-consumptive luminescent method eliminates stirring
Easy to read graphic, backlit display and keypad for
use in any lighting condition
Truly fi eld-worthy, impact resistant, IP-67 waterproof
case and connectors; rubber over molded, non-slip case,
for extra durability and grip
User-replaceable cables in lengths of 1 to 100-meters; cable
management kit included with 4- through 30-meter cables
Pro Comm II allows USB connectivity for use with
Data Manager software and powers the instrument
Stores 5000 data sets (sensor data, date, time, site and
user defi ned information)
Multiple languages include English, Spanish, French,
Italian, Norwegian, Portuguese and German.
Asian language support in the future.
3-year instrument warranty;
2-year cable and probe warranty
YSI Optical BOD Probe
ProOBOD™ - Use in the lab with the ProODO
Smart sensor retains calibration in the probe
User-replaceable, low-maintenance sensor
with +1-year life
2-year warranty; reliableand serviceable, design
reduces cost-of-owners hip and reduces down-time
Probe body tapered to fi
t into a standard 300 mL
BOD bottle; international version also available
Extremely quiet operation
No warm-up time required
Self-stirring to provide representative sample
and improve response t imes
21
®
Specifications
ProODO SystemSpecifications
Dissolved Oxygen
Sensor Type
(% saturation)
Range
Accuracy
Resolution
Dissolved Oxygen
Sensor Type
(mg/L)
Range
Accuracy
Resolution
Temperature
Range
(°C, °F,°K)
Accuracy
Barometer
Range
(mmHg, inHg, mBar, Psi, KPa)
Accuracy
Resolution
Resolution
(instrument with cable and probe)
Optical (dynamic luminescence quenching lifetime detection)
0 to 500% air saturation
0 to 200% air saturation, ± 1% of the reading or ± 1% air saturation, whichever is greater;
200 to 500% air saturation, ± 15% of the reading
0.1% air saturation
Optical (dynamic luminescence quenching lifetime detection)
0 to 50 mg/L
0 to 20 mg/L, ± 0.1 mg/L or ± 1% of reading, whichever is greater;
20 to 50 mg/L, ± 15% of the reading
0.01 or 0.1 mg/L (auto-scaling)
-5 to 70°C
± 0.2°C
0.1°C
375 to 825 mmHg
± 1.5 mmHg from 0 to 50°C
0.1 mmHg
ProODO Additional Specifications
Storage Temperature
Size
Weight with batteries
Probe Dimensions
Power
CableLengths*
Connectors
Warranty
SalinityInput Range
DataMemory
Flow Dependence
Typical Response Time
Calibration
Languages
Certifications
Connectivity
Data Management
User ID
Measurement/
Logging Modes
GLP Compliant
Probe/Sensor Materials
603069 belt clip
-20 to 70°C
8.3 cm width x 21.6 cm length x 2.3 cm depth (3.25 in x 8.5 in x 2.25 in)
475 grams (1.05 lbs)
19 cm length (7.5 in); 2.4 cm diameter (0.95 in)
2 alkaline C-cells; approximately 80 hours - ambient conditions in manual sampling mode
1- 4- 10- 20- 30- 40- 50- 60- and 100-m; (3.3, 13.1, 32.8, 65.6, 98, 131, 164, 197 and 328 ft)
MS (military spec) waterproof with bayonet lock
3-year instrument; 2-year cable and probe; 1-year sensor cap
0-70 ppt; manual (automatically compensates for manual input value)
5000 data sets (sensor data, date, time, site and user defined information)
None
90% in 25 seconds; 95% in 45 seconds
DO - one point or two point with a zero % value; barometer - one point
English, Spanish, German, French, Italian, Norwegian, Portuguese; Asian language support in the future
RoHS, CE, WEEE, C-Tick, VCCI, IP-67, 1-meter drop test, Assembled in USA
USB 2.0; communications saddle and USB cable included
Data Manager desktop software included; 100 user defined folders and site names
Optional User ID for data security
Automatic and Manual sampling modes/Continuous and Interval logging modes
603062 cable
management kit
603075 soft-sided
carrying case
with ProODO, cable,
and accessories
Yes
The following materials may come into contact with the sampling environment:
Xenoy® PBT Polycarbonate blend, Noryl, Stainless Steel, Titanium,
Polyurethane, Santoprene, Acrylic, Polystyrene
* special order cables up to 100-meters in 10-meter increments
YSI ProOBOD Probe Specifications
Accuracy
Range
Resolution
Warranty
Cable Length
Power
Sensor Type
Typical Response Time
Certifications
mg/L
0-20 mg/L, ±0.1 mg/L or ±1% reading, whichever greater; 20-50 mg/L, ±15% reading
% air
0-200%, ±1% reading or ±1%, whichever greater; 200-500%, ±15% reading
temperature
±0.2° C
mg/L
0-50 mg/L
% air
0-500% air saturation
temperature
Ambient (10 to +40° C); Compensation (-5 to +50° C)
mg/L
0.01
% air
0.1%
0.1° C
temperature
2-years; 1-year sensor cap
3-meters (6 feet)
External 110-230 VAC power supply with DC input to sensor
Optical; dynamic luminescence quenching lifetime detection
95% in 22 seconds with stirring; 95% in 40 seconds without stirring
RoHS, CE, WEEE, IP-65, Assembled in USA
22
®
YSI.com/ProODO
YSI.com/ProOBOD
NEW Dsisgsistsasl Professional Series
Handheld Optical Dissolved Oxygen Meter
The new ProODO TM provides traditional YSI quality in a handheld
dissolved oxygen instrument with luminescent optical dissolved
oxygen (DO) technology. The ProODO utilizes “smart” digital sensor
technology which stores calibration data within the sensor. This allows
probes to be placed on any ProODO instrument without re-calibration.
YSI ODO technology reduces the time required calibrating and
maintaining sensors while utilizing a user replaceable sensing element
that requires approximately an annual replacement. There are no
electrodes to clean or solutions to change. Based on usage, calibrations
can be stable for up to one year and are stored in each sensor.
Optical technology also increases DO accuracy and eliminates probe
fouling by common gases such as hydrogen sulfide.
t ExpandeE D0 rangF oG 0-500% wiUI B responsF UJNF oG 590 JO
approYJNateMZ 25 seconds
t NoO-DonsuNptivF lVNJOFscenU NFUIoE eMJNJOatFT stirrinH
t EBTZ tP reBE graphic, backliU EJsplaZ aOE keypBE foS VsF JO anZ
lightinH Dondition
t
AO externaM sUJS
platF NaZ bF requireE tP ensurF B representativF saNple.
The ProODO is a digital signal instrument. Any
ProODO cable can be connected and used on any
ProODO instrument for the field or in a lab BOD
bottle. The luminescent optical probes hold the
calibration information internally.
aOE DonnectoST; rubbeS oveS Nolded, OoO-sliQ case, foS extrB
durabiliUZ aOE grip
t User-replaceablF cablFT JO lengthT oG 1 tP 100-NFteST; cablF
NanageNenU kiU JOcludeE wiUI 4-NFteS aOE longeS cables
t 6S# DonnectioO allowT JnteractioO wiUI powerfuM desktoQ DaUB
t StorFT 2000 daUB sFUT (sensoS daUB, date, UJNe, sitF aOE VseS
t MultiplF languagFT JOcludF EnglisI, SpanisI, FrencI, ItaliaO,
NorwegiaO, PortuguesF aOE GeSNaO. AsiaO languagF supporU
JO UIF Guture.
t 3-yeaS JnstrVNenU Xarranty; 2-yeaS cablF aOE probF Xarranty
Pure
Data for a
Healthy
Planet.®
23
ProODO System Specifications (instrument with cable and probe)
Dissolved Oxygen
(% saturation)
Sensor Type
Range
Accuracy
Resolution
Dissolved Oxygen
(mg/L)
Temperature
(°C, °F, °K)
Barometer
(mmHg, inHg,
mBar, Psi, KPa)
Sensor Type
Range
Accuracy
Resolution
Range
Accuracy
Resolution
Range
Accuracy
Resolution
Optical (dynamic luminescence quenching lifetime detection)
0 to 500% air saturation
0 to 200% air saturation, ± 1% of the reading or ± 1% air saturation,
whichever is greater; 200 to 500% air saturation, ± 15% of the reading
0.1% air saturation
Optical (dynamic luminescence quenching lifetime detection)
0 to 50 mg/L
0 to 20 mg/L, ± 0.1 mg/L or ± 1% of reading, whichever is greater;
20 to 50 mg/L, ± 15% of the reading
0.01 or 0.1 mg/L (auto-scaling)
-5 to 70°C
± 0.2°C
0.01°C
375 to 825 mmHg
± 1.5 mmHg from 0 to 50°C
0.1 mmHg
ProODO Additional Specifications
Storage Temperature
Size
Weight with batteries
Probe Dimensions
Power
Cable Lengths*
Connectors
Warranty
Salinity Input Range
Data Memory
Flow Dependence
Typical Response Time
Calibration
Languages
-20 to 70°C
8.3 cm width x 21.6 cm length x 2.3 cm depth (3.25 in x 8.5 in x 2.25 in)
475 grams (1.05 lbs)
19 cm length (7.5 in); 2.4 cm diameter (0.95 in)
2 alkaline C-cells; approximately 80 hours - ambient conditions in manual sampling mode
MS (military spec) waterproof with bayonet lock
3-year instrument; 2-year cable and probe; 1-year sensor cap
0-70 ppt; manual (automatically compensates for manual input value)
None
90% in 25 seconds; 95% in 45 seconds
DO - one point or two point with a zero % value; barometer - one point
English, Spanish, German, French, Italian, Norwegian, Portuguese; Asian language support
in the future
RoHS, CE, WEEE, C-Tick, VCCI, IP-67, 1-meter drop test, Assembled in USA
USB 2.0; communications saddle and USB cable included
Certifications
Connectivity
Data Management
User ID
Optional User ID for data security
Measurement/LoggingModes Automatic and Manual sampling modes/Continuous and Interval logging modes
GLP Compliant
Yes
Probe/Sensor Materials
PBT Polycarbonate blend, Noryl, Stainless Steel, Titanium, Polyurethane, Santoprene,
Acrylic, Polystyrene
ProODO Ordering Information (order items separately)
626281 ProODO Handheld instrument
626320 Replacement sensing element (included with initial probe purchase)
626250-1 1-m probe/cable for DO/temp
626250-4 4-m probe/cable for DO/temp (includes cable management kit)
626250-10 10-m probe/cable for DO/temp (includes cable management kit)
626250-20 20-m probe/cable for DO/temp (includes cable management kit)
626250-30 30-m probe/cable for DO/temp (includes cable management kit)
626250-40 40-m probe/cable for DO/temp (includes cable management kit)
626250-50 50-m probe/cable for DO/temp (includes cable management kit)
626250-60 60-m probe/cable for DO/temp (includes cable management kit)
626250-100100-mprobe/cable for DO/temp (includes cable management kit)
603069 belt clip
603062 cable
management kit
Accessories Ordering Information (visit ysi.com/accessories)
603075
603074 Hard-sided carrying case
603069 Belt clip to attach instrument to belt
063517 Ultra clamp (attach to instrument to secure it to a desk, boat, etc)
063507
603062 Cable management kit (included with 4- through 100-m cables)
605978 Cable weight, 4.9 oz, attach to stainless steel probe guard
* Special order cable lengths up to 100-meters in 10-meter increments available.
24
603075 soft-sided carrying case with
ProODO, cable, and accessories
The rugged design and fieldworthiness of the Professional
Plus instrument allows you to
perform your job with confidence even in the harshest
field conditions and with the
ProfessionalPlus
s DO, pH,
Conductivity, ORP,
Ammonium, Nitrate,
Chloride, Salinity,
Total Dissolved
Solids, Barometric
Pressure
The YSI Professional Plus accommodates
any combination of Pro Series probe, cable,
and accessory. This compact handheld includes
multiple languages, detailed GLP data, on-screen
Help functionality, auto-buffer recognition, milspec connectors, re-cal prompts, auto-stable and
security passwords to help make your job easier.
s 2,000 data-set
memory with GLP
event logging
Finally, a professional instrument for a true
professional.
s Interval or singleevent logging
capability
s Rubber, over-molded
IP-67 water proof
case
Possible probe choices
s 3-year instrument
warranty; 2-year
cable warranty
s User- upgradeable
software via USB
s Backlit display AND
keypad
s Graphic display with
detailed Help
*
s Rugged cables, connectors, and probes
**
***
X=
Choice of ISE; pH, ORP, pH/ORP (not recommended on the 1010-X cable)
Choice of ISE; Ammonium, Nitrate, or Chloride for fresh water only
Choice of DO; Galvanic, Polarographic
Lab-grade pH and ORP cable/probe options available
Choice of cable length: 1, 4, 10, 20, 30-meter all (up to 100-meters on 20-X only)
Connect from field to lab probes in seconds
Data Manager
Software
s Easy-to-use software to
manage all your data,
set up instruments, or
conduct real-time studies
s View graphical and
tabular data
s USB connection also
powers the instrument
25
lowest overall cost of ownership. Interchangeable probes
and cables reduce down-time
and keeps the Pro Plus ready
whenever and wherever you
are - field or lab.
if complexity is the problem
ease of use is the solution
productivity is the impact
SPECIFICATIONS
(SYSTEM W/4-METER CABLE AND PROBES)
Dissolved Oxygen Sensor Type Polarographic or Galvanic
(%)
Range
0 to 500%
Ammonium***
Accuracy
0 to 200% ± 2% of reading or 2% air
saturation, whichever is greater
200% – 500% ± 6% of reading
Resolution
1% or 0.1% air saturation
(user selectable)
Calibration
1 point and zero
Dissolved Oxygen Sensor Type Polarographic or Galvanic
(mg/L)
Range
0 to 50 mg/L
Accuracy
0 to 20 mg/L (±2% of the reading or
0.2 mg/L, whichever is greater)
20 to 50 mg/L (±6% of the reading)
Resolution
0.1 or 0.01 mg/L (user selectable); 0.1%
air saturation
Calibration
1 point and zero
Temperature
Range
--5 to 70°C
(Field rugged cableA
s)ccuracy
±0.2°C
Resolution
0.1°C
Units
°C, °F, K
Temperature
Range
--5 to 70°C
(Lab-grade)*
Accuracy
±0.35°C
Resolution
0.1°C
Units
°C, °F, K
Depth
4-meters submersion
Conductivity** Sensor Type Four electrode cell
Range
0 to 200 mS/cm
Accuracy
±0.5% of reading or 0.001 mS/cm,
whichever is greater (4-m cable)
±1% of reading or 0.001 mS/cm,
whichever is greater (20-m cable)
Resolution
0.001 mS/cm to 0.1 mS/cm (range
dependent)
Units
μS, mS
Calibration
1 point
Salinity
Sensor Type Calculated from conductivity and
temperature
Range
0 to 70 ppt
Accuracy
±1.0% of reading or 0.1 ppt,
whichever is greater
Resolution 0.01 ppt
Units
ppt, PSU
Calibration
1 point
pH
Sensor Type Glass Combination Electrode
Range
0 to 14 units
Accuracy
±0.2 units
Resolution
0.01 units
Units
mV, pH units
Calibration
1, 2, 3, 4, 5, or 6 point (user selec
table); US, NIST or Custom Buffers
ORP
Sensor Type Platinum button
Range
--1999 to +1999 mV
Accuracy
+/-20 mV in redox standards
Resolution
0.1 mV
Units
mV
Calibration
1 point
Ion Selective Electrode
0 to 200 mg/L-N, 0 to 40°C
±10% of reading or 2 mg/L-N,
whichever is greater
Resolution 0.1 mg/L
Units
mg/L-N, mV
Calibration
1, 2, or 3 point (user selectable)
Depth
17-meters submersion
Nitrate***
Sensor Type Ion Selective Electrode
Range
0 to 200 mg/L-N, 0 to 40°C
Accuracy
±10% of reading or 2 mg/L-N,
whichever is greater
Resolution 0.1 mg/L
Units
mg/L-N, mV
Calibration
1, 2, or 3 point (user selectable)
Depth
17-meters submersion
Chloride***
Sensor Type Ion Selective Electrode
Range
0 to 1000 mg/L, 0 to 40°C
Accuracy
± 15% of reading or 5 mg/L,
whichever is greater
Resolution 0.1 mg/L
Units
mg/L-Cl-, mV
Calibration
1, 2, or 3 point (user selectable)
Depth
17-meters submersion
Total DissolvedSolidsSensor Type
Calculated from conductivity and
(TDS)
temperature
Range
0 to 100 g/L
Cal constant range 0.30 to 1.00
(0.64 default)
Resolution
0.001, 0.01, 0.1g/L
Units
kg/L, g/L
Barometer
Sensor Type Piezoresistive
Range
375 to 825 mmHg
Accuracy
±3 mmHg within ±15°C from
calibration point
Resolution 0.1 mmHg
Units
mmHg, inHg, mbar, psi, kPa, ATM
Calibration
1 point
(INSTRUMENT ONLY AT AMBIENT TEMPERATURE)
pH
Range
-2.60 to 16.60
ORP
Conductivity
Accuracy
Resolution
Range
Accuracy
Resolution
Range
Accuracy
Resolution
Dissolved Oxygen Range
Accuracy
Temperature
* Lab-grade field cables include 605107, -108, -109, 605177, -178, -179
** Derived parameters can include resistivity, salinity, specific conductance, and total dissolved solids
*** ISE sensors for freshwater only
26
Sensor Type
Range
Accuracy
Resolution
Range
Accuracy
Resolution
Units
+/-0.1 mV (0.01 pH units)
0.1 mV (0.01 pH units)
-1999 to +1999 mV
+/-0.5 mV
0.01 mV
0.0 to 200 mS/cm
+/-0.3% FS +/-1 digit for each range
0.0001 mS/cm or 0.1 uS/cm to 0.1
mS/cm (range dependent)
0.00 to 90 mg/L; 0 to 550%
+/-0.2% FS (550% air saturation)
+/- 1 digit (with 1.25 PE membrane
at 10°C)
0.01 mg/L; 0.1% air saturation
-10 to 100.00C
+/-0.2% FS (550% air saturation)
+/- 1 digit (with 1.25 PE membrane
at 10°C)
0.1C
C, F, K
Aqua Fluor
™
Handheld Fluorometer/Turbidimeter
Highlights of the AquaFluor™
t Dual channels allow for quick
toggling between two applications
t Small size easily fits in shirt or jacket pocket
t Dustproof and watertight for field use, it
even floats!
t Single-point plus blank calibration
Handheld Fluor meter/Turbidimeter
AquaFl
The AquaF u r™ is a lightweight, in xpensive, handheld fluorometer/turbidimeter
de l for fi d
t
alsz
and durability
ho eed quick me
apability a ow
Whi
sm
ke the AquaFlu r™ perfect for the
ements away from the aboratory
to measure fl
size, performance h
es
a d t bidity i one
-b
Avai ab
pl .
t Operates using AAA batteries for >1,000
measurements per set
t 5 second warm up
t Low maintenance field fluorometer
not been compromised. The AquaF uor™
brings n w level f simplicity nd economy to Tur
fluor
Dua channe
t12 bit resolution
rD
igns’ li
of
d instrumentatio
Channels
The AquaFluor
TM
channels:
· Turbidity
· In Vivo Ch ophyll
· Extracted Ch orophyll
· B e Gr en A gae - Phycocyanin
· B ue Gr en A gae - Phyc rythrin
· Fluorescei Dye
· Rhodamin Dye
Optional Accessories
t Internal Data Logging stores up to 1,000
points of data
Ammoni
CDOM
· Optical Bright
· PTSA
Conta t Us for C
n
for Wastew ter Treat
t Adjustable Solid Secondary Standard
provides Quick and Easy Checks of
Calibration, Stability and Performance.
nt
m Opti al Kit
27
Aqua Fluor
™
Handheld Fluorometer/Turbidimeter
Application
Minimum Detection Limit
Linear Range
In Vivo Chlorophyll a
0.3 μg/L
0 - 300 μg/L
Weight in Air
Extracted Chlorophyll a*
0.5 μg/L
0 - 300 μg/L
Size
Ammonium*
0.1 μM
0 - 100 μM
CDOM
0.1 ppb
Cyanobacteria
AquaFluor™ Physical Specifications
Warm-up Time
Case
0 - 1000 ppb
150 cells/mL
0.5 ppm
0-30,000 ppm
Fluorescein Dye
0.4 ppb
0 - 400 ppb
Power
Detector
0.4 ppb
0 - 400 ppb
0.5 NTU
0 - 1000 NTU
PTSA
<1 ppb
0 - 1000 ppb
41-104°F; 5-40°C
AquaFluor™ Electrical Specifications
Optical Brighteners
Rhodamine Dye
5 seconds
IP 67 standard; dustproof/waterproof
Temperature
0 - 150,000 cells/mL
Turbidity
13.9 oz; 0.4 kg
1.75” x 3.5” x 7.25”; 4.45 cm x 8.9 cm x 18.4 cm
4 AAA batteries
Photodiode 300nm-1,000 nm capable
*Reagents and Reaction Time Required
Ordering Information
INSTRUMENT
PART NUMBER
AquaFluor™ Handheld Fluorometer/Turbidimeter
ACCESSORIES
8000-010
PART NUMBER
Internal Data Logging
8000-920
Adjustable Solid Secondary Standard*
8000-952
Adjustable Solid Secondary Standard**
12mm Test Tube Adapter***
8000-951
8000-932
Minicell Adapter
8000-936
12x75 mm Round Glass Test Tubes (12 ea)***
10-029A
10x10 mm Square Polystyrene Cuvette (100 ea)****
7000-957
10x10 mm Square Methacrylate Cuvette (100 ea)*****
7000-959
Minicells (200 μL capacity) (1000 ea.)
7000-950
AVAILABLE CHANNELS
PART NUMBER
Turbidity
8000-408
Chlorophyll a in vivo
8000-406
Chlorophyll a Extracted
8000-407
Blue Green Algae - Phycocyanin
8000-412
Blue Green Algae - Phycoerythrin
8000-411
Fluorescein Dye
Rhodamine Dye
8000-405
Ammonium
8000-402
CDOM
8000-401
Optical Brighteners for Wastewater Treatment
8000-403
PTSA
8000-400
8000-409
Contact Us for Custom Optics
*For use with chlorophyll a, phycoerythrin and rhodamine channels only
**For use with fluorescein and phycocyanin channels only
***Required for use with extracted chlorophyll
****Recommended for use with turbidity
*****Required for use with UV (<400nm)
Conta t Us
oll-Free : 1.877.316.8049
Phon : 408.749.0994
Fax : 408.749.0998
Email
Web
[email protected] designs.com
ww tu
designs.com
Addr s
845 West Maude Avenue
Sunnyvale CA 94085
S-0033 Rev. I
28
Trilogy
Laboratory Fluorometer
Features of the Trilogy
t Multifunctional, Compact and Modern Design
t Sample Adaptor accommodates 10 x 10 mm
square plastic cuvettes, 12 x 75 mm round tubes
and 12 x35 mm round vials
t Snap-in Modules Provide Flexibility
Trilogy Laboratory Fluorometer
The Trilogy Laboratory Fluorometer is a compact laboratory instrument for making
fluorescence, absorbance and turbidity measurements using the appropriate snapin Application Module. Trilogy provides you with excellent sensitivity and
measurement range. The all solid-state design ensures you will make reliable and
repeatable readings.
Fluorescence modules are available for chlorophyll a, (extractive acidification
and non-acidification plus in vivo), rhodamine and fluorescein dye, cyanobacteria (phycocyanin and phycoerythrin pigments), CDOM, optical brighteners
and ammonium. For extracted chlorophyll measurements using EPA 445, Trilogy automatically calculates the concentration using the filtered and solvent
volumes. The Turbidity Module uses an IR LED with a wavelength of 860 nm to
meet ISO 7027 requirements for Turbidity water quality measurements.
Snap-In Application Modules
Snap-in modules enable you to select the applications you need today while
being able to easily add capabilities in the future
t Absorbance
- Phosphate
- Nitrate
- Silicate
t Chlorophyll a
t Blue Green Algae - Phycocyanin
t Blue Green Algae - Phycoerythrin
Intuitive Color Touch Screen User
Interface
Store Up to 18 Named One to Five
Point Calibrations
Available Modules
t Turbidity
Touchscreen Highlights
Blank Reads and Automatically
Subtracts in Direct Concentration
Mode
t Rhodamine Dye
t Fluorescein Dye
t Ammonium
t CDOM
t Histamine
t Oil
t Optical Brighteners for Wastewater Treatment
Custom Modules Also Available
29
Trilogy
Laboratory Fluorometer
Fluorescence Module Performance
APPLICATION
MINIMUM DETECTION LIMIT
Chlorophyll a
Phycoerythrin
Phycocyanin
Rhodamine WT
Fluorescein
Ammonium
CDOM
Crude OIl
Refined Oil
Optical Brighteners
0.025 μg/L
150 cells/ml
150 cells/ml
0.01 ppb
0.01 ppb
0.1 μM
0.1 ppb
0.2 ppb
0.25 ppb
1 ppb
Trilogy Physical Specifications
LINEAR RANGE
0-300 μg/L
0-150,000 cells/ml
0-150,000 cells/ml
0-500 ppb
0-500 ppb
0-100 μM
0-1,000 ppb Quinine Sulfate
0-2,000 ppb Quinine Sulfate
0-6,000 ppb Napthalene
0-10,000 ppb Quinine Sulfate
Absorbance Module Performance
Readout
Dimensions
(D x W x H)
Direct Concentration (μg/l, ppb, etc.)
or Raw Fluorescence
12.92” x 10.44” x 8.42”
(32.82 cm x 26.52 cm x 21.39 cm)
Weight
8.1 lbs (3.65 kg)
Operating Temperature
Trilogy Electrical Specifications
Light Source & Detector
APPLICATION
MINIMUM DETECTION LIMIT
LINEAR RANGE
Nitrate
Silicate
Phosphate
0.04 mg/L of total inorganic N
3 μg/L of total inorganic Si
1 μg/L of total inorganic P
0-14 mg/L of total inorganic N
0-3,000 μg/L of total inorganic Si
0-930 μg/L of total inorganic P
Turbidity Module Performance
Data Output
MINIMUM DETECTION LIMIT
LINEAR RANGE
Turbidity
0.05 NTU
0-1,000 NTU
Light Emitting Diode
and Photodiode
100% ASCII format through a 9 pin
RS-232 serial cable at 9600 baud
PC Operating System
(optional if connected to PC)
Power
APPLICATION
60 - 105˚ F (15 - 40˚C)
Window 98 or later
100 to 240VAC Universal Power Supply
included, Output 12 VDC 0.84A Max
Ordering Information
INSTRUMENT
PART NUMBER
Trilogy Laboratory Fluorometer
FLUORESCENCE MODULES
7200-000
PART NUMBER
Chlorophyll a Acidification
Chlorophyll Non-Acidification
Chlorophyll a in-vivo
Rhodamine/Phycoerythrin
Phycocyanin
Fluorescein
CDOM/Ammonium
Histamine
Short Oil
Crude Oil
Optical Brighteners for Wastewater Treatment
TURBIDITY MODULE
Turbidity
7200-040
7200-046
7200-043
7200-042
7200-044
7200-048
7200-041
7200-049
7200-062
7200-063
7200-047
ABSORBANCE MODULES
Phosphate Kit
Silicate Kit
Nitrate Kit
Absorbance (requires filter paddle)
560/10 nm Filter Paddle
600/10 nm Filter Paddle
750/10 nm Filter Paddle
PART NUMBER
7200-060
PART NUMBER
7200-070
7200-072
7200-074
7200-050
7200-051
7200-052
7200-053
Contact Us
Toll-Free : 1.877.316.8049
Email : [email protected]
Address:
Phone : 408.749.0994
Web : www.turnerdesigns.com
845 West Maude Avenue
Fax : 408.749.0998
Sunnyvale, CA 94085
S-0068 Rev. M
30
10-AU
Field Fluorometer
Highlights of the 10AU
t &xceptional Sensitivity
t Automatic or Manual Ranging
t "OBlog and Digital Output
t Field Installable Optical Kits
t &BTy to Read LCD Display
t /ow 20% Lighter!
10AU Field Fluorometer
The 10AU Fie d Fluoromet r s
ugged, fiel d-po tab
n trument that can
be set up for continuou -flow monitoring r discret sample nalyses.
Measurement a e extremely stable ith stability meas red in months r
w
k
oppo ed to day
change of ex itati
sily mea u ed
h u
Watertight filter paddles enable q ick
and e ission fi te
a variety of
mp
nds c
b
site.
User Configured Options
t Standard or Red PMT
t Continuous Flow Monitoring or
Discrete Sample Analysis
Availabl Opti al Kit
Optica kits
ith ppropriate fi te
d amps a
ai ab
f r a w de ange of
pplicati n a d a be e si y insta ed in the fie d o ab ndividu l fi ters a d
lamps can also be pu ch
ed for
sto ized applications.
Available Optical Kits
· Chlo
ophyll
Extracted and/o In Vivo
B ue Green A gae - Phycocyanin (f eshwat r)
· Blu Gr n Algae - Phycoerythrin (m
· Rhod m e WT Dye Tracing
rin )
Flu resc n Dye Tracing
· Amm n
· CDOM
· Cr de Oil (Long Wavelength)
· Refi ed Oil (Short Wavele gth)
· Histamine
· Opti l Brighten s f Wastew t
Conta t Us for Cu
Optional Accessories
t Internal Data Logging & Electronic Chart
Recording
t Temperature Compensation for Continuous
Flow Measurements
Treatment
t Solid Secondary Standard
m Opti al Kit
31
10-AU
Field Fluorometer
Ordering Information
10AU Electrical Specifications
BASE INSTRUMENT W/ WATERTIGHT CASE
PART NUMBER
10AU Fluorometer with Red PMT
1100-100
10AU Fluorometer with Standard PMT
1100-101
SAMPLE CELL
Light Source
Detector
Lamp (4 watts, 8000 hours lamp life)
PhotoMultiplier Tube; Standard (300-650 nm), Red (185-870 nm)
AC Power
100-130 V; 200-240 V, 50/60 Hz, 30 watts
DC Power
11-16 V; 2.5 amperes
PART NUMBER
25 mm One-Piece Continuous Flow System
1100-020
25 mm & 13 mm Discrete Sample Test Tube Holder Set
10-AU-030
SOFTWARE
Digital Output
Analog Output
PART NUMBER
Internal Data Logging & Electronic Chart Recording
100% ASCII data output via RS-232 at 4800 or 9600 bps
10-AU-450
10AU Detection Limits
Temperature Compensation Package (On-Line Systems) 1100-500
Extracted Chlorophyll a
OPTICAL KITS
0.1, 1, 2, or 5 volts
PART NUMBER
In Vivo & Extractive Chlorophyll a
10-037R
Extractive Chlorophyll a
10-040R
In Vivo Chlorophyll a
10-096R
Blue Green Algae - Phycocyanin (freshwater)
10-305
Blue Green Algae - Phycoerythrin (marine)
10-304
Rhodamine WT Dye
10-041R
Fluorescein Dye
10-086R
Ammonium/CDOM
10-303
Crude Oil (Long Wavelength Oil)
10-302R
Refined Oil (Short Wavelength Oil)
10-301R
Optical Brighteners for Wastewater Treatment
10-302R
Rhodamine WT Dye
Fluorescein Dye
0.025 μg/L using EPA Method 445.0
0.01 ppb RWT in potable water
0.01 ppb Fluorescein in potable water
10AU Linear Range
Extracted Chlorophyll a
0 - 250 μg/L
Rhodamine WT Dye
0 - 250 ppb
Fluorescein Dye
0 - 250 ppb
10AU Physical Specifications
Contact Us for Custom Optical Kits
Weight
12.6 kg (28.5 lbs)
OPTIONAL ACCESSORIES
PART NUMBER
Height
24 cm (9.45 in)
Solid Secondary Standard
10-AU-904
Width
55 cm (21.65 in)
Shipping Case
10-AU-060
12 VDC Power & Signal Cable w/ Clips
10AU-810
Depth
34 cm (13.39 in)
Universal Power & Signal Cable, 115 VAC & 230 VAC
10AU-800
Operating Temperature
0-55° C, 32-131° F (ambient)
Conta t Us
Toll-Free : 1.877.316.8049
Email
Phon : 408.749.0994
Web
Fax : 408.749.0998
[email protected]
tu
designs.com
designs.com
Addr s
845 West Maude Avenue
Sunnyvale CA 94085
998-0865 Rev. C
32
CYCLOPS– 7
SUBMERSIBLE SENSORS
Cyclops-7 Highlights
t Integrate into a C6 Multi-Sensor Platform or
any third-party platform
t &xtremely small size - 4.3” x 0.9”
Cyclops-7 Submersible Sensors
The CYCLOPS-7 line of submersible sensors is designed for integration into multiparameter platforms requiring a high performance, compact sensor at a
significantly lower price than traditional submersible sensors. The CYCLOPS-7
combination of price, performance and size make the sensor very attractive for
oceanographic, freshwater and dye tracing applications.
t Affordable price / excellent value
t Very low power consumption
t &xcellent turbidity rejection
t Custom versions available
Fluorometer Performance
Physical Dimensions
Linearity: 0.99R2
Length x Diameter: 4.3” x 0.9”, 14.0 x 2.2 cm
Application
Minimum Detection Limit
Dynamic Range
Chlorophyll a*
1.3 μg/L
500 μg/L
Rhodamine WT
1.4 ppb
1000 ppb
Cyanobacteria
150 cells/mL
2,000,000 cells/mL
CDOM
0.2 ppb QS**
1000 ppb QS**
0.05 NTU
Environmental Characteristics
Temperature Range:
Ambient: 0 to 50 deg C
Water Temp: -2 to 50 deg C
Depth Range: 600 meters
Signal Output: 0 - 5 VDC
* Chlorophyll specifications determined with Rhodomonas SP culture
** Quinine Sulfate
Turbidity
Weight: 5.0 oz, 160 gm
Supply Voltage Range: 3 - 15 VDC
1000 NTU
Power Requirements: <300mW typical
Ordering Information
Chlorophyll a
2100-000-C
Blue Green Algae
Solid Secondary Standard
2100-900
Flowthrough Cap
2100-600
t Phycoerythrin
2100-000-&
Shade Cap
2100-700
t Phycocyanin
2100-000-P
2’ Pigtail Cable w/ locking sleeve
2100-750
Rhodamine
2100-000-R
Fluorescein
2100-000-F
Turbidity
2100-000-T
CDOM
2100-000-U
Optical Brighteners
2100-000-B
Crude Oil
2100-000-O
Titanium Housing also available
Contact Us for Custom Optics
33
Submersible Fluorometer
Highlights of the C3
t 0rder up to ThrFF 0QUJcal Sensors
t Temperature Sensor Included
t Robust Memory – 0ver 480,000 Data Points!
t &BTy to Use C-Soft Software with Data
Management Capabilities
t 0QUional Depth Sensor Available
C3 Submersible Fluorometer
The C3 Submersible Fluorometer can be configured with up to three optical
t 0QUional Mechanical Wiper Available
sensors ranging from the ultraviolet to the infrared spectrum. Internal memory
storage capacity combined with an external submersible lithium ion battery
allows the C3 to run during extended or short-term deployments. Each C3
comes with a factory installed temperature sensor and a depth rating of 600
meters. An optional factory installed depth sensor and mechanical wiper is
also available. The C-Soft Windows based software allows for intuitive calibration, datalogging set up, file management capabilities as well as digital data
integration.
Customized Optical Sensors
Choose up to three optical sensors to be factory installed for a variety of
applications.
Available Optical Sensors
· Turbidity
· Chlorophyll a in vivo
· Blue Green Algae - Phycocyanin
· Blue Green Algae - Phycoerythrin
· Rhodamine Dye
· CD0M
· CruEF 0il
· 0ptical Brighteners
Digital integration with a CTD
profiler or third party platform
Extended Deployments in the
Self-Contained Mode with
Submersible Battery
Secondary Solid Standard used to
check signal stability or correlating
to a primary standard
Contact Us for Custom Optics
34
Submersible Fluorometer
C3 Physical Specifications
Weight in Air
Length
23 cm 9.1 in
Diameter
10 cm 3.9 in
Material
Delrin Plastic
Temperature
Robust Memory
Over 480,000
Data Points!
Depth
Easy to Mount Battery
Bracket with Eye Holes
Required for External Lines
-2 to 50 degrees C.
0 to 600 meters
C3 Electrical Specifications
External Power
Mechanical Wiper
Enables Accurate Readings
1.64 kg 3.6 lbs
8 to 30 VDC
Extended Battery Life
Output
Interface
Digital Signal
RS232 Interface
Maximum Sample Rate
1 Second
Maximum Power Requirements
1 Watt
Ordering Information
INSTRUMENT
PART NUMBER
AVAILABLE FACTORY INSTALLED OPTICS
PART NUMBER
C3 Submersible Fluoromter
2300-000
Turbidity
2300-240
Chlorophyll a in vivo
2300-200
Blue Green Algae - Phycocyanin
Blue Green Algae - Phycoerythrin
2300-231
2300-230
Rhodamine Dye
2300-210
C3 ACCESSORIES
PART NUMBER
C3 Mechanical Wiper
2300-450
Pressure Sensor
2300-360
Submersible Battery Pack
2200-601
Battery Pack Bracket
2300-603
Flow Cap
2300-700
Shade Cap
2300-500
Shade Cap Weight
2300-510
Solid Secondary Standard
2300-900
CDOM
2300-251
Crude Oil
2300-253
Optical Brighteners
2300-252
Contact Us for Custom Optics
Cables Also Available, Contact Sales for Details
Contact Us
Toll-Free : 1.877.316.8049
Email : [email protected]
Address:
Phone : 408.749.0994
Web : www.turnerdesigns.com
845 West Maude Avenue
Fax : 408.749.0998
Sunnyvale, CA 94085
35
Highlights of the Platform
t Six ports Available for Turner Designs
Cyclops-7 Sensors
t Pressure and Depth Integrated
t Fast Sampling Rate
t Windows™ Based User Interface with
Data Management
t Robust Memory - Over 100,000 data points!
C6 Multi-Sensor Platform
t Field installable mechanical wiper allows for
extended deployments
The C6 Multi-Sensor Platform integrates up to six Cyclops-7 fluorescence
t Depth Rating up to 600 meters
and turbidity sensors for extended or short-term deployments. The C6
provides individual automatic gain control, calibration, digital data reporting and datalogging for each Cyclops-7 sensor. Each C6 comes with a
factory-installed temperature and pressure sensor. The C6 Windows™ based
user interface allows for intuitive calibration, datalogging set up, and file
downloading. Existing Cyclops-7 users can easily integrate their sensor into the
C6 Multi-Sensor Platform.
Interchangeable
Sensors
Interchangeable Sensors
Cyclops-7 sensors can be easily field installed for a variety of applications.
+
Available Sensors for easy Integration
· Turbidity
· Chlorophyll a in vivo
· Blue Green Algae - Phycocyanin
· Blue Green Algae - Phycoerythrin
· Fluorescein Dye
· Rhodamine Dye
· CDOM
· Crude Oil
· Optical Brighteners
Integrates up to Six Turner Designs
Cyclops Sensors
Interchangeable Sensors and
Easy to Install
+
Add Additional Sensors in the Future
Temperature & Depth Already Integrated
2
Contact Us for Custom Optics
36
Optional Dual-Armed Mechanical
Wiper Available
C6 Specifications
Weight in Air
2.74 kg ; 6.0 lbs.
Length
25.8 cm ; 10.2 in
Length with Sensors Attached
33.8 cm ; 13.3 in
Diameter
Material
2
Robust Memory
over 100,000
Lines of Data!
Dual Armed Mechanical Wiper
Minimizes Biofouling
Temperature
Easy to Mount Battery Bracket
with eye holes used for
External Lines or Fasteners
Depth
10.2 cm; 4.0 in
316 Stainless Steel; Delrin
-2 to 50 degrees C.
0-600 meters
C6 Electrical Specifications
Extended Battery Life
over 85 Days at 15 Minute Intervals!
External Power
Output
Ordering Information
Interface
INSTRUMENT
PART NUMBER
C6 Multi-Sensor Platform
2200-000
C6 ACCESSORIES
PART NUMBER
Mechanical Wiper
2200-450
Wiper Brush Replacement Kit
2200-452
Submersible Battery Pack
2200-601
Battery Pack Bracket
2200-603
Flow Cap
2200-700
Shade Cap
2200-500
Solid Secondary Standard*
2100-900
Boosters (Set of 2)**
2200-900
10 Meter Extender Cable**
105-2595
25 Meter Extender Cable**
105-2596
50 Meter Extender Cable**
105-2597
Maximum Sample Rate
8 to 20 VDC
Digital Signal
RS232 Interface
1 Second
CYCLOPS-7 SENSOR
Turbidity
2100-000-T
Chlorophyll a in vivo
2100-000-C
Blue Green Algae - Phycocyanin
2100-000-P
Blue Green Algae - Phycoerythrin
2100-000-E
Fluorescein Dye
2100-000-F
Rhodamine Dye
2100-000-R
CDOM
2100-000-U
Crude Oil
2100-000-O
Optical Brighteners
2100-000-B
Contact Us for Custom Optics
*Only available for visible wavelengths
**Boosters are required for cables greater than 5 meters in length
37
Active Fluorometer
Features
t %JgJUally JOtegratFT JOto B C5% PS
thJrd-partZ Tystem
t Low QowFS cPOsumptJPO <1 8 typJDal
t &xtFOdFE CatterZ MJfF
(Over 35 EayT aU 30 TFcPOd JOtervals)
PhytoFlash Submersible Active Fluorometer
PhytoFlasI JT aO in situ 4uCNFSTJCMF AcUJvF Fluorometer thaU cBO CF VTFd tP
determJOF thF RVaOtum FócJFOcZ PG QhytoplaOLtPO JO Coth oMJHPtrophJD BOE
mesotrophJD FOvJrPONeOts. PhytoFlasI JT EJTUJOcU GroN PUIFS øuorescFOcF
JOstrumeOtT oO thF market JO thaU Jt JT UIF örTU TPMJd-statF JOstrumeOU capaCMF PG
t -BrHF JOterOBM daUB MPHgJOH NFNorZ
(10,000 QPJOts)
t 0QUJPOBM solJE TFcPOdary TUaOdard QrovJdeT
B RuJDk, FBTy methPE tP verJGy DalJCratJPO
t ReporUT daUB JO FJthFS RelaUJvF FluorescFOce
6OJts (RFU) Pr %JrecU CPOceOtratJPO
varJaCMF øuoresceOcF measuremeOtT oO OaturBM cPOceOtraUJoOT PG QhytoQMBOk-
toO. ThF soMJd-statF Qlatform allows foS B NuDI wJEFr raOHF PG uses EVF tP JUT small
TJze, Qower FóDJeOcy, NorF TUaCMF coNQPOFOts, aOE MowFS QrJcF QoJOt.
Accuracy & Sensitivity
IOcreasFE TFOTJUJWJtZ for olJgotrPQIJD
systems (MJOJmVN %etecUJPO -JmJU
0.15
˜H/M)
AccuratF measuremeOUT oG (Fo) BOE
(Fm) øVPresceOcF aU loX
coOceOtraUJoOs
Versatility
PhytoFlaTI DBO CF operated JO UhreF
dJffereOU NPdes:
The 4elf-CoOUBJOFd Mode DBO CF Vsed wJtI thF
JOterOBM Eata loggJOH Tystem BOE recharHFBClF
Cattery Qack.
Applications
t In situ measuremeOU oG QhytoplaOktoO QIotosyOtheUJD Qarameters
t IOEJcatoS oG OutrJeOt status oG QlaOktoOJD Blgae
t %etectJPO oG tIF POTet oG Blgal Clooms
t OceaOograpIJc, FstuarJOe, MJNOologJcaM aOd rJverJOF studJes
t %etermJOaUJoO PG OPO-photochemJcaM RVFOchJOH JO lBCoratorZ mode
t MeasuremeOt PG QhotosyOthetJD FócJFOcy foS all algaF usJOH #lVF PhytoFlash
t MeasuremeOt PG QhotosyOthetJD FócJFOcy foS cyaOPCacterJB (Clue-greeO
algae) VTJOH Red PhytoFlash
38
The IOtegrated Mode Bllows PhytoFlash tP
CF matFE XJUI BOE coOtrolled Cy a thJrd-partZ
system.
The LaCoratory Mode QrovJEFT GVll reporUJOH oG
tIF respoOsF curve.
Active Fluorometer
Technique
The PhytoFlash detection system is best described as a short-pulse, multiple
Measured Parameters
turnover variable fluorescence system. The technique utilizes 3 low-intensity LEDs
to monitor minimum fluorescence (Fo) and, after saturating the cells in the sample
chamber using 6 high-intensity LEDs, measure maximum fluorescence (Fm). The
LEDs are arranged to provide an even distribution of light throughout the entire
sample volume. The low intensity of the monitoring LEDs prevents an increase in
the photosynthetic rate. Users are able to define the saturation duration
(200 - 10,000 ms) of the high intensity LEDs. Under the Laboratory Mode users are
able to view the response curve. A dark Flow Through Cap is available to allow for
Fo
Minimum fluorescence
Fm
Maximum fluorescence
Fv
Variable fluorescence (Fm - Fo)
Maximum quantum yield of
photochemistry in PSII
Fv/Fm (yield)
Blank
Calculated blank value used in calibration
Response Curve
Available during laboratory mode
dark adaptation for all three modes.
PhytoFlash Physical Specifications
Ordering Information
INSTRUMENT
PART NUMBER
PhytoFlash Submersible Active Fluorometer (Blue Version)
2500-000
PhytoFlash Submersible Active Fluorometer (Red Version)
2500-001
Titanium PhytoFlash Submersible Active Fluorometer (Blue Version)
2500-000-T
Titanium PhytoFlash Submersible Active Fluorometer (Red Version)
2500-001-T
*Titanium withstands corrosion better than stainless steel and is recommended for stationary
deployments in highly corrosive environments.
PHYTOFLASH ACCESSORIES
PART NUMBER
Submersible Battery Pack
2500-600
Flow Cap
2500-710
Shade Cap
2500-510
Solid Secondary Standard (for Blue PhytoFlash)
2500-900
Solid Secondary Standard (for Red PhytoFlash)
2500-901
2 Foot Analog Interface Cable with Locking Sleeve
2500-170
10 Meter Analog Interface Cable with Locking Sleeve
2500-171
25 Meter Analog Interface Cable with Locking Sleeve
2500-172
50 Meter Analog Interface Cable with Locking Sleeve
2500-173
Interface Cable and 12V Power Supply
2500-150
Dummy Plug
105-2570
Minimum Detection Limit
Dynamic Range*
0.15 μg/l
Low: 0-5 μg/l High 0-100 μg/l
Weight in Air
3.25 lbs (1.47 kg)
Weight in Water
1.01 lbs (0.46 kg)
Length x Diameter
Temperature
12” x 3” (30.5 cm x 7.6 cm)
-2 to 50 degrees C
Depth
600 meters
*Chlorophyll specifications determined with Dunaliella monoculture
PhytoFlash Electrical Specifications
Power Requirements
Supply Voltage Range
Detector
Light Source
<1 W Typical
8 - 30 VDC
Photodiode
Light Emitting Diode
Patents Issued 7301158 and 7470917
Contact Us
Toll-Free : 1.877.316.8049
Email : [email protected]
Address:
Phone : 408.749.0994
Web : www.turnerdesigns.com
845 West Maude Avenue
Fax : 408.749.0998
Sunnyvale, CA 94085
S-0070 Rev. F
39
SUNA V 2 (Submersible Ultraviolet Nitrate Analyzer)
A Versatile UV Nitrate Sensor for Operation in
Diverse Environments
The SUNA V2 (Submersible Ultraviolet Nitrate Analyzer) is a chemicalfree UV nitrate sensor based on the ISUS (In Situ Ultraviolet
Spectroscopy) UV nitrate measurement technology developed at MBARI.
Satlantic has adapted the technology to develop the SUNA V2 to
measure nitrate in increasingly more challenging environments including
extremely turbid and high CDOM conditions. With improved optics and
built-in logic intelligence, the SUNA V2 measures nitrate with industry
leading accuracy and stability over a wide range of environmental
conditions, from blue-ocean nitraclines to storm runoff in rivers and
streams.
The SUNA V2 is the ultimate solution for real-time nutrient monitoring.
Every SUNA V2 now comes with our proven universal real-time nitrate
processing algorithm, which has been upgraded to include adaptive
sampling intelligence that automatically adjusts for signal strength. Also
included in every SUNA V2 is a 10 mm pathlength, a class based nitrate
calibration, serial data output and a 500 meter depth rating.
In addition to these standard features, a wide range of optional features
provide the ability to customize the instrument to meet your specific
research and deployment needs.
OPTIONAL FEATURES
•
•
•
•
•
•
Reduced 5mm pathlength for high turbidity environments
Active fouling control with fully integrated Hydro-Wiper
Internal data logging and scheduling with 2 GB memory
Full Freshwater & seawater calibrations
USB communications and data download
SDI-12 interface
SUNA SPECIFICATIONS
PERFORMANCE
Limit of Detection
Detection Range
Accuracy
Short-term precision (at 3cr)
Drift (per hour lamp time)
Turbidity range
0.5 µM (FW or SW with TIS correction)
2.0 µM (SW 0-40 psu)
3000 µM (10 mm path length)
4000 µM (5 mm path length)
± 2 µM (± 0.028 mgI1-N) or ± 10% of reading
0.3& µM (FW or SW with TIS correction)
2.4 µM (SW 0-40 psu)
0.3 µM (FW or SW with TIS correction)
1.0 µM (SW 0-40 psu)
625 NTU* (10 mm path length; absent other absorbing species)
1250 NTU (5 mm path length; absent other absorbing species)
*Nephelometric Turbidity Units
OPTICS
Path Length
Wavelength Range
Lamp Type
Lamp Lifetime
10 mm & 5 mm (high turbidity option)
190-370 nm
Continuous Wave, Deuterium Lamp
900 h
ELECTRICAL
1nput Voltage
Power Consumption
8-18 VDe & 8-15 with Hydro-Wiper
7.5 W (0.625 A at 12 V) nominal
40
The HOBO U26 Dissolved Oxygen logger measures
concentrations of oxygen in lakes, streams, rivers,
estuaries, and coastal waters. Used by aquatic biologists,
hydrologists, and other research professionals to monitor
water quality, the U26 is ideal for climate change and
environmental impact studies as well as ecological and
oceanographic research.
The HOBO U26 combines the high accuracy, robust
performance of industry-leading RDO ® Basic (Rugged
Dissolved Oxygen) sensor technology with an easyto-maintain design all at a fraction of the cost of other
monitoring options.
Key Advantages
Optical DO sensor technology for long-lasting calibration with less maintenance
Software corrects for measurement drift from fouling; provides salinity-adjusted
DO concentration and percent saturation
Easy-to-replace sensor cap lasts six months
Powerful, Intuitive Software
HOBOware ® Pro software makes it easy to graph and an
alyze
lyzedissolved
dissolved
monitoring
projects. It features a Dissolved Oxygen Data
Assistant which provides salinity-adjusted DO
concentration and percent saturation.
The software also provides the option of start-and-end
point calibration for added accuracy and to correct for
data export to Microsoft ® Excel and other programs.
41
42
HOBO® Conductivity Data Logger
The HOBO U24 Conductivity Logger is a high-accuracy, cost-effective data logger for
measuring conductivity and temperature in streams, lakes, and other freshwater
sources. Ideal for monitoring aquifers for saltwater intrusion and road and agricultural runoff, the U24 is easy to deploy and maintain. It features a non-contact sensor
to minimize drift-related measurement errors, open access to the sensor for cleaning, and software-based drift compensation.
Features
Non-contact sensor reduces sensor drift for easy maintenance
Provides easy access to sensor for cleaning and shedding air bubbles
HOBOware Pro software enables start/end-point calibration to compensate for any
fouling and provides easy conversion to specific conductance and salinity
USB optical interface provides high-speed, reliable data offload in wet environments
Compatible with the HOBO Waterproof Shuttle for easy and reliable
data retrieval and transport
43
HOBO® Conductivity Data Logger
Specifications
Memory - 18,500 temperature and conductivity measurements when using one conductivity range;
14,400 sets of measurements when using both conductivity ranges (64kbytes)
Sample rate - 1 second to 18 hrs, fixed or multiple-rate sampling with up to 8 user-defined sampling
intervals
Battery life - 3 years (@ 1 min logging)
Maximum Depth - 70 m (225')
Operating Range - 0 to 50°C (32° to 122°F) - non freezing
Weight - 193 gm (6.82 ounces), buoyancy in freshwater: -59.8 gm (-2.11 ounces)
Size - 3.18 cm diameter x 16.5 cm, with 6.3 mm mounting hole (1.25" diameter x 6.5", ¼” hole)
Calibrated Range - Conductivity: Low Range: 0 to 1,000 uS/cm; Full Range: 0 to 10,000 uS/cm Temperature: 5 to 40C (41 to 104F)
Extended Range - Conductivity: Low Range: 0 to 2,500 uS/cm; Full Range: 0 to 15,000 uS/cm Temperature: 0 to 40C (32 to 104F)
Accuracy - Conductivity: 3% of reading, or 5 uS/cm, whichever is greater / Temperature: 0.1C (0.2F)
Resolution - Conductivity: 1 uS/cm - Temperature: 0.01°C (0.02°F)
Response Time - 1 second to 90% of change
CE - Not CE compliant yet
44
&90 - "EWBODFE 8BUFS 2VBMJUZ .POJUPSJOH 1MBUGPSN
WBUFS RVBMJUZ NPOJUPSJOH
UIBt’T mFME-SFBEZ
4VSGBDF WBUFS &
GSPVOE WBUFS .oOJUoSJOH
CBQUVSJOH BDDVSBUF EBUB JO GSFTIXBUFS
FOWJSPONFOUT JT FBTZ XJUI &X0.
EXO1 sonde
EXO2 sonde
t 4VSGBDF BOE
HSPVOEXBUFS
NPOJUPSJOH EPXO UP
250 N (828 GU)
t #MVFUPPUI XJSFMFTT
DPNNVOJDBUJPO
t 2VJDL BOE FBTZ
DBMJCSBUJPO PG NVMUJQMF
TFOTPST
t WFMEFE UJUBOJVN
TFOTPST JODMVEJOH
DPOEVDUJWJUZ, EJTTPMWFE
oYZHFO, G%0., Q),
03P, UVSCJEJUZ, BOE
UPUBM BMHBF
t C5% QMVT 3-5
BEEJUJPOBM TFOTPST
t CPBTUBM BOE NBSJOF
NPOJUPSJOH EPXO UP
250 N (828 GU)
t 4FBNMFTT JOUFHSBUJPO
BOE “EBJTZ DIBJOJOHw
JOUP NPOJUPSJOH
TZTUFNT
t 'MFYJCMF TFOTPS
QBZMoBE/DPOmHVSBtJPOT
t WFMEFE UJUBOJVN
TFOTPST
t "OUJGPVMJOH XJQFS
IFMQT UP FYUFOE
EFQMPZNFOUT UP NPSF
UIBO 90 EBZT
0VU PG UIF Cox, &X0 JT SFBEZ UP HP XJUI:
t PSF-JOTUBMMFE TFOTPST GPS FBTZ TFU-VQ PG
GBDUPSZ-DPOmHVSFE TZTUFNT
t 8JSFMFTT DPNNVOJDBUJPO SFEVDFT OVNCFS PG
mFME DBCMFT
t 0OCPBSE EJBHOPTUJDT NJUJHBUF TFU-VQ BOE
DPOmHVSBUJPO FSSPST
8JUI B IJHIMZ FGmDJFOU QPXFS NBOBHFNFOU QMBUGPSN, SPCVTU
DPOTUSVDUJPO, BOE B DIFNJTUSZ-GSFF BOUJ-GPVMJOH TZTUFN, &X0 BMMPXT
BDDVSBUF EBUB DPMMFDUJPO GPS VQ UP 90 EBZT CFUXFFO TFSWJDF JOUFSWBMT.
45
Instrument Specifications
*
EXO1 Sonde
Ports
Size
Weight
4 sensor ports
Peripheral port: 1 power communication port
Diameter: 4.70 cm (1.85 in)
Length: 64.77 cm (25.50 in)
1.42 kg (3.15 lbs) with 4 probes, guard and batteries installed
EXO2 Sonde
Ports
7 sensor ports (6 ports available when central wiper used)
Peripheral ports: 1 power communication port; 1 auxiliary expansion port
Size
Diameter: 7.62 cm (3.00 in)
Length: 71.10 cm (28.00 in)
Weight
3.60 kg (7.90 lbs) with 5 probes, guard and batteries installed
Sondes
Operating Temperature
-5 to 50˚C
Storage Temperature
-20 to 80˚C (except 0 to 60˚C for pH and pH/ORP sensors)
Depth Rating
0 to 250 m (0 to 820 ft)
Communications
Computer Interface: Bluetooth wireless technology, RS-485, USB
Output Options: USB with signal output adapter (SOA); RS-232 & SDI-12 with DCP-SOA
Sample Rate
Up to 4 Hz
Battery Life
90 days **
Data Memory
512 MB total memory; >1,000,000 logged readings
Sensors
Calculated Parameters
Ammonium **
ORP
Salinity
Chloride **
pH
Specific Conductance
Conductivity
Temperature
Total Dissolved Solids
Depth
Total Algae (Chlorophyll + BGA-PC or PE
Dissolved Oxygen
Turbidity
Fluorescent Dissolved Organic
Matter (fDOM)
Vented Level **
**)
Total Suspended Solids
Nitrate **
EXO Handheld
Size
Width: 12.00 cm (4.72 in)
Height: 25.00 cm (9.84 in)
Weight
0.71 kg (1.56 lbs) without batteries
Operating System
Windows CE 5.0
Operating Temperature
-10 to 50˚C
Storage Temperature
-20 to 80˚C
IP Rating
IP-67
Data Memory
2 GB total memory; >2,000,000 data sets
Accessories
Cables (non-vented)
Flow cells
Sonde/sensor guard
Carrying case
KOR software
Calibration cup
DCP Signal Output Adapter
USB Signal Output Adapter
Anti-fouling components
Warranty
1 Year
pH, ORP, and optical DO membranes
2 Years
Cables, sondes (bulkheads), handheld, and the following sensors: conductivity,
temperature, depth, and optical sensors
* Specifications indicate typical performance and are subject to change.
Please check EXOwater.com for up-to-date information.
** Typically 90 days at 20˚C at 15-minute logging interval; temperature/conductivity, pH/
ORP, DO, and turbidity sensors installed on EXO1; or temperature/conductivity, pH/ORP,
DO, total algae, and turbidity sensors installed with central wiper that rotates once per
logging interval on EXO2. Battery life is heavily dependent on sensor configuration.
46
EXO Bluetooth modules comply with Part 15C of FCC Rules
and have FCC, CE Mark and C-tick approval. Bluetooth-type
approvals and regulations can be country specific. Check
local laws and regulations to insure that the use of wireless
products purchased from Xylem are in full compliance.
** Release in 2013. BGA-PE specs TBD.
Sensor Specifications
Sensor
*
Range
Ammonium**
11
0 to 200 mg/L
(ammonia with pH sensor)
Barometer
Accuracy
Response Resolution
*
±10% of reading or 2 mg/L-N, w.i.g.
1
375 to 825 mmHg
± 1.5 mmHg from 0 to 50°C
Blue-green Algae
Phycocyanin (PC) or
Phycoerythrin (PE)**
0 to 100 μg/L PC;
0 to 100 RFU
Linearity: R 2 > 0.999 for serial dilution
of Rhodamine WT solution from 0 to
100 μg/mL PC equivalents
Detection Limit: 0.04 μg/L PC
Chloride**
0 to 1000 mg/L
±15% of reading or 5 mg/L, w.i.g.
(part of Total Algae sensor)
11
(part of Total Algae sensor)
Conductivity
2
0 to 10 m (0 to 33 ft)
Depth 4
0 to 250 m (0 to 820 ft) ±0.04% FS (±0.10 m or ±0.33 ft)
Vented Level**
0 to 10 m (0 to 33 ft)
0 to 500%
air saturation
Dissolved Oxygen
Optical
0.1 mmHg
T63<2 sec
.01 μg/L PC; 0.01 RFU
0.01 mg/L
0 to 50 mg/L
T63<2 sec
0.01 μg/L Chl; 0.01
RFU
T63<2 sec
0.0001 to 0.01 mS/cm
(range dependent)
T63<2 sec
0.001 m (0.001 ft)
(auto-ranging)
±0.04% FS (±0.004 m or ±0.013 ft)
0 to 100 m (0 to 328 ft) ±0.04% FS (±0.04 m or ±0.13 ft)
(non-vented)
–
–
Linearity: R > 0.999 for serial dilution
of Rhodamine WT solution from 0 to
400 μg/L Chl equivalents
Detection Limit: 0.09 μg/L Chl
0 to 100: ±0.5% of reading or 0.001
mS/cm, w.i.g.; 100 to 200: ±1% of
reading
0 to 200 mS/cm
3
0.01 mg/L
2
0 to 400 μg/L Chl;
0 to 100 RFU
Chlorophyll
-
±0.03% FS (±0.003 m or ±0.010 ft)
0 to 200%: ±1% of reading or 1%
saturation, w.i.g.; 200 to 500%: ±5% of
reading 5
0 to 20 mg/L: ±0.1 mg/L or 1% of
reading, w.i.g.; 20 to 50 mg/L: ±5% of
reading 5
T63<5 sec
T63<2 sec
0.1% air saturation
6
0.01 mg/L
fDOM
0 to 300 ppb Quinine
Sulfate equivalents
(QSE)
Linearity: R 2 > 0.999 for serial dilution
of 300 ppb QS solution
Detection Limit: 0.07 ppb QSE
Nitrate** 11
0 to 200 mg/L-N
±10% of reading or 2 mg/L-N, w.i.g.
ORP
-999 to 999 mV
pH
0 to 14 units
±0.1 pH units within ±10˚C of calibration temp;±0.2 pH units for entire
temp range 8
0 to 70 ppt
±1.0% of reading or 0.1 ppt, w.i.g.
T63 <2 sec
Specific Conductance
(Calculated from Conductivity and
0 to 200 mS/cm
±0.5% of reading or .001 mS/cm,
w.i.g.
–
0.001, 0.01, 0.1 mS/cm
(auto-scaling)
Temperature
-5 to 50°C
-5 to 35°C: ±0.01°C
35 to 50°C: ±0.05°C
T63<1 sec
.001 °C
0 to 100,000 g/L
Cal constant range
0.30 to 1.00
(0.64 default)
Not Specified
–
variable
0 to 1500 mg/L
ot Specified
T63<2 sec
0 to 4000 FNU
0 to 999 FNU: 0.3 FNU or ±2% of
reading, w.i.g.; 1000 to 4000 FNU:
±5% of reading 12
T63<2 sec
Salinity ( Calculated from
Conductivity and Temperature)
Temperature)
Total Dissolved Solids
(Calculated from Conductivity
and Temperature)
Total Suspended Solids
(Calculated from Turbidity
and TDS)
Turbidity 11
(TDS)
(TSS)
1
± 20 mV in Redox standard solutions
10
10
.01 ppb QSE
–
0.01 mg/L
T63< 5 sec
7
T63<3 sec
9
0.1 mV
0.01 units
0.01 ppt
variable
0 to 999 FNU: 0.01 FNU;
1000 to 4000 FNU: 0.1
FNU
Accuracy specifications apply to conductivity levels of 0 to 100,000
μS/cm.
Relative to calibration gases
6
When transferred from air-saturated water to stirred deaerated water
7
When transferred from water-saturated air to Zobell solution
8
Within the environmental pH range of pH 4 to pH 10
9
On transfer from water-saturated air to rapidly stirred air-saturated water at
a specific conductance of 800 μS/cm at 20˚C; T63<5 seconds on transfer from
water-saturated air to slowly-stirred air-saturated water.
10
Temperature accuracy traceable to NIST standards
11
Calibration: 1-, 2-, or 3-point, user-selectable
12
Specification is defined in AMCO-AEPA Standards
All sensors have a depth rating to 250 m (820 ft), except shallow and medium depth
sensors and ISEs. EXO sensors are not backward compatible with 6-Series sondes.
4
5
* Specifications indicate typical performance and are subject to change. Please
check EXOwater.com for up-to-date information.
Accuracy specification is attained immediately following calibration under controlled
and stable environmental conditions. Performance in the natural environment may
vary from quoted specification.
2
0-30˚C
0-40˚C
w.i.g. = whichever is greater
Outputs of specific conductance (conductivity corrected to 25˚C) and total
dissolved solids are also provided. The values are automatically calculated from
conductivity according to algorithms found in Standard Methods for the Examination
of Water and Wastewater (Ed. 1989).
1
3
** Release in 2013. BGA-PE specs TBD.
47
YSI 600QS (Quick Sample™)
The Easy Solution to Handheld Sampling
Packaged for convenience, the combination of the YSI 650MDS displaydatalogger and the YSI 600QS sonde allows you to collect 9 parameters
simultaneously in real time. Designed for reliable field use, the 650MDS
features an IP-67, impact-resistant case, and utilizes internal, non-volatile
unprecedented sensor reliability and parameter measurement systems.
and polluted waters.
t Rapid-PulsF ™stirring-independenU EissolveE
oxygeO, accepteE foS compliancF Nonitoring
t Collect 9 parameters simultaneously in real time
t Dissolved oxygen, dissolved oxygen % saturation, temperature,
conductivity, pH, ORP1, and depth1 are measured simultaneously
t Specific conductance, salinity, total dissolved solids and resistivity
are calculated and displayed with measured parameters at the
users discretion
t Small compact sonde fits easily into 2-inch wells
t Compatible with EcoW
2
t Menu-driven, easy-to-use interface for 650MDS and 600QS sonde to PC
The 600QS (Quick Sample)
t Sonde communicates via RS-232 to 650MDS and PC, and via
SDI-12 to data collection platforms
t Easy-to-use sensor diagnostics that help insure accurate, high
quality data acquisition
t 3-year warranty on the 650MDS and 2-year warranty on the 600QS
sonde.3
1
optional sensor, 2 EcoWatch is not necessary for operation, calibration or sensor diagnostics
refer to warranty statement for conditions: extended warranties are also available
3
Feature-Packed Performance
Pure
Data for a
Healthy
Planet.®
A cost-effective
combination of two
outstanding YSI products
Battery Life
With the standard alkaline battery configuration of 4 C-cells, the YSI 650 will power
itself and a YSI 6600 sonde continuously for approximately 30 hours. Or, choose the
rechargeable battery pack option with quick-charge feature.
Optional GPS Interface
Designed to NMEA protocol, the YSI 650MDS will display and log real-time GPS
readings with a user supplied GPS interfaced with YSI 6-Series sondes.
48
YSI 600QS Display & Datalogger (650MDS) Specifications
Operating -10 to +60°C for visible display
Storage -20 to +70°C
Temperature
Waterproof Rating
IP-67 for both the standard alkaline battery configuration and for the rechargeable battery pack option
Connector
MS-8; meets IP-67 specification
Width 4.7 in, 11.9 cm
Length 9 in, 22.9 cm
Weight with batteries 2.1 lbs, 0.91 kg
Dimensions
VGA; LCD with 320 by 240 pixels with backlight
Display
Power
Standard 4 alkaline C-cells with detachable battery cover
Optional Ni metal hydride battery pack with attached battery cover and 110/220 volt charging system
Communications
Optional GPS
NMEA 0183; requires user-supplied GPS and YSI 6115 Y-cable
Backlight
4 LEDs illuminating LCD; user-selectable
Keypad
20 keys, including instrument on/off, backlight on/off, enter, esc, 10 number/letter entry keys, 2 vertical
arrow keys, 2 horizontal arrow keys, period key, and minus key
Warranty
3 years
YSI 600QS Sonde (600R) Specifications
Fresh, sea or polluted water
Medium
Dimensions
Diameter
Length
Weight
1.65 in, 4.2 cm
14 in, 35.6 cm
1.1 lbs, 0.5 kg
Power
External only, 12 V DC or power supplied by 650MDS
Sensor
Range
Resolution
Accuracy
Rapid Pulse™ Dissolved
Oxygen, % air saturation
0 to 500%
0.1 %
0 to 200% : ± 2% of reading or 2% air saturation, whichever is greater; 200 to 500%: ±6% of
reading
Rapid Pulse™ Dissolved
Oxygen, mg/L
0 to 50 mg/L
0.01 mg/L
0 to 20 mg/L: ± 0.2 mg/L or 2% of reading,
whichever is greater; 20 to 50 mg/L: ±6% of
reading
Conductivitys
0 to 100 mS/cm
0.001 to 0.1 mS/cm
(range-dependent)
±0.5% of reading + 0.001 mS/cm
Salinity
0 to 70 ppt
0.01 ppt
±1% of reading or 0.1 ppt, whichever is greater
Temperature
-5 to +50°C
0.01°C
±0.15°C
pH
0 to 14 units
0.01 unit
±0.2 unit
-999 to +999 mV
0.1 mV
±20 mV
0 to 200 feet, 0 to 61 m
0.001 feet, 0.001 m
±0.4 feet, ±0.12 m
ORP
Depth
Medium
according to algorithms found in Standard Methods for the Examination of Water and Wastewater (ed 1989).
Ordering Information
600QS-01
600QS-02
600QS-03
600QS-04
600QS-05
600QS-06
600QS-07
600QS-08
49
ANALITE NEP495
TURBIDITY & TEMPERATURE LOGGING
PROBE
The ANALITE NEP495 turbidity probes can monitor and log turbidity and temperature in a sturdy self-contained
package that is easy to set up and easy to selectively download the data collected.
The ANALITE NEP495 microprocessor based turbidity probe is designed for monitoring and logging
applications where turbidity levels of up to 1,000NTU may be encountered. Available ranges are 40NTU,
100NTU, 400NTU and 1,000NTU, which can be set by the user. The ANALITE NEP495 probe, with its integral
wiper assembly, is designed to operate over an extended period of time where bio-fouling or sedimentation
build-up is likely. The ANALITE NEP495 turbidity probes may be submerged to a depth rating of 100 meters
(approx. 330 feet).
The ANALITE NEP495 probe use 90° optics and employs infrared light in accordance with ISO7027 and use a
unique modulation technique that ensures almost total rejection of ambient light conditions. The salient features
of the ANALITE NEP495 probes are tabled below:
Feature
NEP495
RS232 Interface
Yes
Integral and Auto Wiping
Yes
Turbidity Logging
Yes
Temperature Logging
Yes
User Range Select
Yes
User Calibrate
Yes
Firmware Upgradeable
Yes
The user may calibrate the probe at any time as well as allowing later versions of fi rmware to be uploaded by
the user via the RS232 interface.
The ANALITE NEP495 probes are similar to the ANALITE NEP395 probe but with the inclusion of temperature
measurement and a fl exible self contained logging function. As normally supplied, the ANALITE NEP495 can
store over 30,000 data sets with each data set consisting of turbidity, temperature, time and date. Logging
intervals can be set from less than 1 second to over 18 hours. Data is stored in non-volatile memory.
The ANALITE NEP495 is self-contained requiring no external power or commands once logging has
commenced. The internal batteries have a life expectancy of over 30,000 data sets or about 60 days whichever comes fi rst and assuming a wipe prior to each reading.
50
Specifi cations:
Logging Interval User set, from 1 second to over 18
hours in 1 second increments.
Factory set to 900 seconds (15 mins).
Technique
90° Infra-Red (ISO7027).
Range
40, 100, 400 and 1,000NTU – set by
user, factory default setting is 100NTU.
Resolution
Range
40NTU
100NTU
400NTU
1,000NTU
Repeatability
±1% at 25°C.
Linearity
Better than 1% for 40NTU, 100NTU and
400NTU, 3% for 1,000NTU (using 3
point calibration).
Temperature
Output
Measurements
Data Capacity
32,000 data sets minimum but depends
on memory capacity installed in the
probe.
Memory technology is FlashRAM
Logging stops when memory is full.
Calibration
Turbidity - 2 or 3-point calibration for
each range. May be set by the user
only through the RS232 interface and
for the range selected. Can revert back
to factory calibration settings after user
calibration.
Temperature – factory calibration only.
-10°C to 50°C with ±0.1°C resolution
and ±0.5°C accuracy. Time constant 50
seconds in water.
Power
3 off – C cells alkaline.
0.5mA STANDBY, 15mA ON.
40mA ON and wiping.
RS232 – 1200, 2400, 4800 or 9600BPS,
7 data bits, even parity, one stop bit. The
factory default setting is 9600BPS.
Wipe Time
8 seconds nominal.
Weight
1,800gms - including batteries.
Dimensions
532mm long overall, 38mm diameter.
Construction
316 Stainless steel casing. Screw on
End Cap to allow battery replacement
and PC connection via RS232 interface.
Depth Rating
100m (330ft) static water column.
Resolution
±0.01NTU
±0.02NTU
±0.1NTU
±0.2NTU
RS232 Realtime
Latest turbidity measurement.
Mean and Sample Variance.
Median.
Minimum.
Maximum.
Probe battery voltage.
External (water) temperature.
RS232 Logging
Each logging point generates a data set
containing:
Turbidity in NTU
Water Temperature in °C
Time the data set was recorded.
Date the data set was recorded.
Operating Temp. -10°C to 50°C.
Storage Temp.
-20°C to 55°C.
Download Cable 3 meters with DB9 termination.
Accessories
32mm dia.
38mm dia.
Protective shroud for optics.
NEP49SHRD 38mm dia.
Replacement wiper kits NEP19WIPE.
10mm
hole
198
500
7
25
Specifi cations subject to change without notice.
File: NEP495 Brochure Mar 2004 V1.indd
51
600OMS
V2
Optical Monitoring System
Dissolved Oxygen, Turbidity, Chlorophyll, Blue-Green Algae, or
Rhodamine in a Low-Cost Package
Measure any one of the parameters above in combination with temperature,
conductivity, and depth or vented level in fresh, sea, or polluted water.
V2 can take advantage of the newest optical sensors from YSI:
ROX Reliable Oxygen (YSI 6150) and two new blue-green algae sensors (YSI
turbidity sensor, the YSI 6025 chlorophyll sensor, as well as the revolutionary YSI
V2 also incorporates innovations in sensor
body.
t WipeE opticT foS NBYJNVN Bnti-foulinH protection
t IdeBM foS long-terN deployNents
t LoX poweS requireNents
t Field-replBceBblF opticBM sensors
t 150,000 reBEJnH NeNory
t IntegrBtF witI DCPs
t CoNpBtiblF witI YS* 650.%4 EisplBZ BOE dBtBMogger
The YSI 600OMS
V2
and optical sensors
Pure
Data for a
Healthy
Planet.®
Low-cost, single
parameter optical
monitoring system
Sensor performance verified*
V2
Program (ETV). For information on which sensors were
52
YSI 600OMS Sensor Specifications
Range
Resolution
Accuracy
ROX™
Optical Dissolved Oxygens
% Saturation
0 to 500%
0.1%
0 to 200%: ±1% of reading or 1% air saturation,
whichever is greater; 200 to 500%: ±15% of
reading
ROX™
Optical Dissolved Oxygens
mg/L
0 to 50 mg/L
0.01 mg/L
0 to 20 mg/L: ± 0.1 mg/L or 1% of reading,
whichever is greater; 20 to 50 mg/L: ±15% of
reading
Conductivityss
0 to 100 mS/cm
0.001 to 0.1 mS/cm
(range dependent)
±0.5% of reading + 0.001 mS/cm
Salinity
0 to 70 ppt
0.01 ppt
±1% of reading or 0.1 ppt, whichever is greater
Temperature
-5 to +50°C
0.01°C
±0.15°C
Turbiditys
6136 Sensor*
0 to 1,000 NTU
0.1 NTU
±2% of reading or 0.3 NTU, whichever is
greater**
Rhodamines
0-200 μg/L
0.1 μg/L
±5% reading or 1 μg/L, whichever is greater
Depth
Medium
Shallow
Vented Level
t Maximum depth rating for all optical probes is 200 feet, 61 m.
**In YSI AMCO-AEPA Polymer Standards.
Standard
Methods for the Examination of Water and Wastewater (ed 1989).
Range
Detection Limit
Resolution
Linearity
BGA - Phycocyanins
~0 to 280,000 cells/mL†
0 to 100 RFU
~220 cells/mL§
1 cell/mL
0.1 RFU
R2 > 0.9999**
BGA - Phycoerythrins
~0 to 200,000 cells/mL†
0 to 100 RFU
~450 cells/mL§§ 1 cell/mL
0.1 RFU
R2 > 0.9999***
Chlorophylls
6025 Sensor*
~0 to 400 μg/L
0 to 100 RFU
~0.1 μg/L§§§
R2 > 0.9999****
t Maximum depth rating for all optical
probes is 200 feet, 61 m.
BGA = Blue-Green Algae
RFU = Relative Fluorescence Units
~ = Approximately
† Explanation of Ranges can
be found in the ‘Principles of
Operation’ section of the 6-Series
Manual, Rev D.
§ Estimated from cultures of Microcystis aeruginosa.
§§ Estimated from cultures Synechococcus sp.
§§§ Determined from cultures of Isochrysis sp. and
chlorophyll a concentration determined via extractions.
YSI 600OMS V2
Sonde Specifications
Medium
Fresh, sea or polluted water
Dimensions
1.65 in, 4.2 cm
21.3 in, 54.1 cm
1.3 lbs, 0.6 kg
1.4 lbs, 0.7 kg
Diameter
Length
Weight
Weight with Batteries
0.1 μg/L Chl
0.1% RFU
**Relative to serial dilution of Rhodamine WT
(0-400 ug/L).
***Relative to serial dilution of Rhodamine WT
(0-8 μg/L).
****Relative to serial dilution of Rhodamine
WT (0-500 ug/L).
Power
External 12 V DC
Internal Battery Option 4 AA Alkaline cells, 25 to 30 days at 15 minute sampling interval at 25°C
Ordering Information
600-01
600OMS V2 sonde, conductivity, temperature, optical port
600-02
600OMS V2 sonde, conductivity, temperature, optical port, internal batteries
600-03
600OMS V2 sonde, conductivity, temperature, optical port, shallow depth
600-04
600OMS V2 sonde, conductivity, temperature, optical port, shallow depth, internal batteries
600-05
600OMS V2 sonde, conductivity, temperature, optical port, medium depth
600-06
600OMS V2 sonde, conductivity, temperature, optical port, medium depth, internal batteries
600-07
600OMS V2 sonde, conductivity, temperature, optical port, shallow vented depth
600-08
600OMS V2 sonde, conductivity, temperature, optical port, shallow vented depth, internal
batteries
53
NEW
600XL V2-1 and 600XLM V2-1 Sondes
Measure multiple parameters simultaneously
parameters simultaneously, including:
Temperature
Conductivity
pH
ORP
Depth or Level
Salinity
Resistivity
TDS
Both sondes have one optical port, allowing for measurement of an
additional parameter with one of the following optical sensors:
ROX™ Optical Dissolved Oxygen
Turbidity
Chlorophyll
Blue-Green Algae (freshwater or marine)
Rhodamine WT
Each optical sensor has an integrated anti-fouling wiper which prolongs
deployment times (thus reducing operating costs) and improves the quality
of data.
Economical Logging and Spot Sampling System
in situ
grammable intervals and store 150,000 readings. At one-hour intervals, the
instrument will log data for about 75 days utilizing its own power source.
external power.
Left: 600XL V2-1 with two-piece
probe guard; right: 600XLM V2-1
sonde with optical DO sensor
(bottom) and batteries (top)
Pure
Data for a
Healthy
Planet.®
Multiparameter sampling
or logging in a compact
sonde for ground water,
dredging, and spot
sampling applications
t Either sonde down 2" wells (1.65" OD)
t Optical sensor port provides a multipurpose platform
t Field-replaceable sensors for quicker maintenance
t Easily connects to data collection platforms
t Anti-fouling wipers on optical sensors extend deployment times
t Compatible with YSI 650 Multiparameter Display System
t Flow cell available for pump-through applications
t Horizontal measurements in very shallow waters
Connect with Data Collection Platforms
Either sonde can easily connect to the YSI 650 handheld logger/display, YSI
6200 DAS (Data Acquisition System), web-enabled YSI EcoNet® or your own
data collection platform, via SDI-12, for remote and real-time monitoring
applications.
54
Sonde Features
· ROX™ Optical DO: An extremely durable DO sensor with excellent stability, insensitivity to
times while reducing operating costs.
· Field-Replaceable Sensors allow users to quickly and easily replace damaged sensors in the
· Power Management: Battery life is 34 days at a 15-minute interval or 75 days at a 1-hour
interval with optical DO sensor installed.
· Key Applications: ground water monitoring, dredging, spot sampling, education, and
long-term monitoring studies.
YSI 600XL V2-1 and 600XLM V2-1 Sonde Specifications
Available Sensors*
Operating Environment
Medium
Temperature
Depth
Temperature, conductivity, pH, ORP, optional depth (shallow, medium, or
shallow vented), and one optical sensor (dissolved oxygen, turbidity, chlorophyll,
rhodamine, or blue-green algae)
Fresh, sea, or polluted water
-5 to 50˚C
Storage Temperature
-40 to 60˚C for sonde and sensors except pH and pH/ORP
-10 to 60˚C for pH and pH/ORP sensors
Material
PVC, stainless steel
Diameter
1.65 in (4.19 cm)
Length
600XL V2
600XLM V2
Weight
600XL V2
600XLM V2
25.1 in (63.8 cm) without depth sensor; 27.1 in (68.8 cm) with depth and
no bottom weight
28.5 in (72.4 cm) without depth sensor; 30.5 in (77.5 cm) with depth and
no bottom weight
1.96 lbs. (0.87 kg) with depth and no bottom weight
2.15 lbs. (1.05 kg) with depth and no bottom weight
Communications
RS-232C, SDI-12
Memory
384 kb (150,000 individual parameter readings)
Power
Battery Life
600XL V2
600XLM V2
External 12 V DC
4 AA Alkaline batteries or external 12 V DC
Approximately 30 days at 20˚C at a 15-minute logging interval with optical DO,
temperature, conductivity, pH/ORP, and depth sensors operative
* Note: Rapid Pulse™ polarographic-style DO sensor is not available on the V2 sondes. Please refer
to the 600XL or 600XLM sondes.
Standard Accessories
Integrated depth sensor t Two-piece probe guard with bottom
Conductivity/temp sensor weight
pH/ORP sensor
t Carrying case
t
(other lengths available)
t Long calibration cup
t
t Maintenance kit
t Flow cell kit (optional)
ROX optical DO sensor with extended bulkhead
55
: 4 I Environmental
NEW
YSI 6820 and 6920 V2 Sondes
With 2 optical ports and new sensor options
Measure multiple parameters simultaneously including:
Temperature
Conductivity
And 2 of the following optical sensors:
Specific Conductance
ROX Optical DO NEW
Salinity
Turbidity
Resistivity
Chlorophyll
TDS
Blue-Green Algae NEW
pH
(Phycocyanin or Phycoerythrin)
ORP
Rhodamine
Depth or Level
Nitrate, Ammonium or Chloride
t 4elf-cMFBOJOH optJDBM TeOToST wJUI JNQroveE wiping
t Field-replaceabMF TeOToST
t 6920 V2 IBT B bVJMU-JO CBUterZ coNQBrtNeOU foS Mong-terNin situ
Nonitoring
Take Advantage of YSI’s New Optical Sensors
In addition to turbidity, chlorophyll, and rhodamine, YSI now offers these optical
sensors:
ROX Reliable Optical Dissolved Oxygen
The ROX sensor uses lifetime luminescence detection technology
to offer the most reliable oxygen sensor with the lowest possible
maintenance effort. Experience significantly less membrane
maintenance while obtaining excellent accuracy, sensitivity, and range.
The YSI 6820 V2 and 6920 V2 Sondes
Pure
Data for a
Healthy
Planet.®
Upgraded, compact sondes
for field sampling and data
collection platforms
Blue-Green Algae (BGA)
YSI’s fluorescence-based blue-green algae sensors will allow you to monitor bluegreen algae populations where their presence is a concern. Whether providing an
early warning to an algal bloom, tracking taste and odor-causing species in drinking
water supplies, or conducting ecosystem research; YSI BGA sensors will provide
sensitive and reliable in situ data.
6820 and 6920 Upgrades Available
YSI is committed to offering our customers reliable and cost-effective water
monitoring solutions. To this end, we are offering V2 Upgrades for existing
6820/6920s. Upgrades will be available from YSI Authorized Service Centers and
will include the new 6820/6920 V2 bulkhead, an Optical Dissolved Oxygen Sensor,
calibrated by an experienced YSI service technician.
Sensor performance verified*
The 6820 V2 and 6920 V2 sondes use sensor technology that was verified
through the US EPA’s Environmental Technology Verification Program (ETV). For
information on which sensors were performance-verified, turn this sheet over and
look for the ETV logo.
56
YSI 6820 V2 & 6920 V2 Sensor Specifications
Range
Resolution
Accuracy
Optical Dissolved Oxygens
% Saturation
0 to 500%
0.1%
0 to 200%: ±1% of reading or 1% air saturation,
whichever is greater; 200 to 500%: ±15% of
reading
Optical Dissolved Oxygens
mg/L
0 to 50 mg/L
0.01 mg/L
0 to 20 mg/L: ± 0.1 mg/L or 1% of reading,
whichever is greater; 20 to 50 mg/L: ±15% of
reading
Conductivityss
6560 Sensor
0 to 100 mS/cm
0.001 to 0.1 mS/cm
(range-dependent)
±0.5% of reading + 0.001 mS/cm
Salinity
0 to 70 ppt
0.01 ppt
±1% of reading or 0.1 ppt, whichever is greater
Temperature
6560 Sensor
-5 to +70°C†
0.01°C
±0.15°C
pH
6561 Sensor
0 to 14 units
0.01 unit
±0.2 unit
ORP
-999 to +999 mV
0.1 mV
±20 mV
0.001 feet, 0.0003 m
0.001 feet, 0.0003 m
0.001 feet, 0.001 m
±0.01 feet, 0.003 m
±0.06 feet, ±0.02 m
±0.4 feet, ±0.12 m
Depth
Vented Level 0 to 30 feet, 0 to 9 m
Shallow 0 to 30 feet, 0 to 9 m
Medium 0 to 200 feet, 0 to 61 m
Turbiditys
6136 Sensor
0 to 1,000 NTU
0.1 NTU
±2% of reading or 0.3 NTU, whichever is greater‡
Nitrate/nitrogensss
0 to 200 mg/L-N
0.001 to 1 mg/L-N
(range dependent)
±10% of reading or 2 mg/L, whichever is greater
Ammonium/ammonia/
nitrogensss
0 to 200 mg/L-N
0.001 to 1 mg/L-N
(range dependent)
±10% of reading or 2 mg/L, whichever is greater
Chloridesss
0 to 1000 mg/L
0.001 to 1 mg/L
(range dependent)
±15% of reading or 5 mg/L, whichever is greater
Chlorophylls
6025 Sensor
0 to 400 μg/L
0.1 μg/L Chl; 0.1% FS
Rhodamines
0-200 μg/L
0.1 μg/L
±5% reading or ±1 μg/L, whichever is greater
† Sensor only. Operating temperature of sonde is -5 to 45° C.
‡ In YSI AMCO-AEPA Polymer Standards.
t Maximum depth rating for all optical probes is 200 feet, 60.96 m.
ttReport outputs of specific conductance (conductivity corrected to 25° C), resistivity, and total dissolved solids are
Methods for the Examination of Water and Wastewater (ed 1989).
tttFreshwater only, Maximum depth rating of 50 feet, 15.2 m.
BGA - Phycocyanins
Ranges
Detection Limits
Linearitys
0-200,000 cells/mL†
150 cells/mL§
R2 = 0.9999*
0-200,000 cells/mL
400 cells/mL
R2 = 0.999**
BGA - Phycoerythrin
s
s
Maximum depth rating for all optical
probes is 200 feet, 60.96 m. Preliminary
Specifications.
‡
† Estimated from cultures of
Microcystis aeruginosa.
‡ Estimated from cultures of PE
containing blue-green algae.
R2 = 0.99994***
§§
§ Estimated from cultures of
Microcystis aeruginosa.
§§ Estimated from cultures of PE
containing blue-green algae.
*Relative to serial dilution of Rhodamine WT (0-400 ug/L).
**Relative to serial dilution of Microcystis aeruginosa cultures (0200,000 cells/mL).
*** Relative to serial dilution of Rhodamine WT (0-8 μg/L).
YSI 6820 V2 & 6920 V2 Sonde Specifications
6820
V2
6920
V2
Medium
Fresh, sea or polluted water
Fresh, sea or polluted water
Temperature
-5 to +45°C
-5 to +45°C
Communications
RS-232, SDI-12
RS-232, SDI-12
Software
EcoWatch®
EcoWatch®
Dimensions
2.86 in, 7.3 cm
13.5 in, 34.3 cm
3.4 lbs, 2.3 kg
2.85 in, 7.24 cm
18 in, 45.7 cm
4 lbs, 1.8 kg (batteries installed)
External only, 12 V DC
Internal: 8 AA-size alkaline batteries
External: 12 V DC
Power
Diameter
Length
Weight
57
NEW
YSI 6600
V2
Sonde
With 2 or 4 optical ports and new sensor options
V2 sonde
simultaneous measurement of conductivity (salinity), temperature, depth or level,
V2-4 also measures these parameters: dissolved oxygen,
turbidity, chlorophyll, and blue-green algae; the V2-2 measures two of the four
parameters simultaneously. Additional calculated parameters include total dissolved
Take advantage of YSI’snew optical sensor design and anti-fouling wiper control for
improved reliability during extended deployments.
t Self-cleaninH opticaM sensorT witI JntegrateE wipeST removF biofoulinH
aOE NaintaJO IigI datB BccuracZ
t OptimaM poweS NanagemenU aOE builU-JO batterZ compartmenU
extendT in situ NonitorinH periods
Take Advantage of YSI’s New Optical Sensors
optical sensors:
Complete Data Record
The YSI 6600 V2-4 Sonde, with
4 optical sensor ports, is the only
instrument available to simultaneously
measure dissolved oxygen, turbidity,
chlorophyll, and blue-green algae!
Pure
Data for a
Healthy
ROX Reliable Optical Dissolved Oxygen
interference and does not require regular membrane changes.
Blue-Green Algae (BGA)
green algae populations where their presence is a concern. Whether providing an
early warning to an algal bloom, tracking taste and odor-causing species in drinking
water supplies, or conducting ecosystem research, YSI BGA sensors will provide
sensitive and reliable in situ data.
Sensor performance verified*
V2
Planet.®
sheet over and look for the ETV logo.
Upgraded sondes
for rugged long-term
deployment
6600 Upgrades Available
V2 Upgrades for existing 6600s.
Upgrades will be available from YSI Authorized Service Centers and will include the
new 6600 V2
experienced YSI service technician.
58
YSI 6600 V2 Sensor Specifications
Range
Resolution
Accuracy
ROX™
Optical Dissolved Oxygens
% Saturation
0 to 500%
0.1%
0 to 200%: ±1% of reading or 1% air saturation,
whichever is greater; 200 to 500%: ±15% of
reading
ROX™
Optical Dissolved Oxygens
mg/L
0 to 50 mg/L
0.01 mg/L
0 to 20 mg/L: ± 0.1 mg/L or 1% of reading,
whichever is greater; 20 to 50 mg/L: ±15% of
reading
Dissolved Oxygenss
% Saturation
6562 Rapid Pulse™ Sensor*
0 to 500%
0.1%
0 to 200%: ±2% of reading or 2% air saturation,
whichever is greater; 200 to 500%: ±6% of
reading
Dissolved Oxygenss
mg/L
6562 Rapid Pulse™ Sensor*
0 to 50 mg/L
0.01 mg/L
0 to 20 mg/L: ± 0.2 mg/L or 2% of reading,
whichever is greater; 20 to 50 mg/L: ±6% of
reading
Conductivitysss
6560 Sensor*
0 to 100 mS/cm
0.001 to 0.1 mS/cm
(range dependent)
±0.5% of reading + 0.001 mS/cm
Salinity
0 to 70 ppt
0.01 ppt
±1% of reading or 0.1 ppt, whichever is greater
Temperature
6560 Sensor*
-5 to +50°C
0.01°C
±0.15°C
pH
6561 Sensor*
0 to 14 units
0.01 unit
±0.2 unit
ORP
-999 to +999 mV
0.1 mV
±20 mV
Turbiditys
6136 Sensor*
0 to 1,000 NTU
0.1 NTU
±2% of reading or 0.3 NTU, whichever is
greater**
Nitrate/nitrogenssss
0 to 200 mg/L-N
0.001 to 1 mg/L-N
(range dependent)
±10% of reading or 2 mg/L, whichever is greater
Ammonium/ammonia/
nitrogenssss
0 to 200 mg/L-N
0.001 to 1 mg/L-N
(range dependent)
±10% of reading or 2 mg/L, whichever is greater
Chloridessss
0 to 1000 mg/L
0.001 to 1 mg/L
(range dependent)
±15% of reading or 5 mg/L, whichever is greater
Rhodamines
0-200 μg/L
0.1 μg/L
±5% reading or 1 μg/L, whichever is greater
Depth
Deep
Medium
Shallow
Vented Level
t Maximum depth rating for all optical probes is 200 feet, 61 m. Turbidity and Rhodamine are also available in a Deep
Depth option (0 to 200 m).
tt Rapid Pulse is only available on 6600 V2-2 (two optical ports version).
**In YSI AMCO-AEPA Polymer Standards.
Standard
Methods for the Examination of Water and Wastewater (ed 1989).
tttt Freshwater only. Maximum depth rating of 50 feet, 15.2 m. 6600 V2-2 has 3 ISE ports; not available on the 6600V2-4.
Range
Detection Limit
Resolution
Linearity
1 cell/mL
0.1 RFU
R2 > 0.9999**
Blue-Green Algae
Phycocyanins
~0 to 280,000 cells/mL
0 to 100 RFU
~220 cells/mL
Blue-Green Algae
Phycoerythrins
~0 to 200,000 cells/mL†
0 to 100 RFU
~450 cells/mL§§ 1 cell/mL
0.1 RFU
R2 > 0.9999***
Chlorophylls
6025 Sensor*
~0 to 400 μg/L
0 to 100 RFU
~0.1 μg/L§§§
R2 > 0.9999****
t Maximum depth rating for all optical
probes is 200 feet, 61 m. Also available in
a Deep Depth option (0 to 200 m).
RFU = Relative Fluorescence Units
† Explanation of Ranges can
be found in the ‘Principles of
Operation’ section of the 6-Series
Manual, Rev D.
§ Estimated from cultures of Microcystis aeruginosa.
§§ Estimated from cultures Synechococcus sp.
§§§ Determined from cultures of Isochrysis sp. and
chlorophyll a concentration determined via extractions.
†
§
0.1 μg/L Chl
0.1% RFU
**For serial dilution of Rhodamine WT (0-400 ug/L).
***For serial dilution of Rhodamine WT (0-8 μg/L).
****For serial dilution of Rhodamine WT
(0-500 ug/L).
YSI 6600 V2 Sonde Specifications
Medium
Temperature
Communications
Fresh, sea or polluted water
Operating -5 to +50°C
Storage -10 to +60°C
RS-232, SDI-12
EcoWatch®
Software
Dimensions
Power
59
Diameter
Length, no depth
Length, with depth
Weight
3.5 in, 8.9 cm
19.6 in, 49.8 cm
21.6 in, 54.9 cm
7 lbs, 3.18 kg (batteries installed,
with depth)
External 12 V DC
Internal 8 C-size alkaline batteries
Y S I Environmental
NEW
6600 EDS Extended Deployment System
Measure over 10 parameters in severe fouling environments
Building upon the unprecedented accuracy and reliability of YSI’s
stirring-independentRapid PulseTM dissolved oxygen system, as well as
on the improved and proven wiped turbidity sensor, YSI has produced
the YSI 6600 EDS (Extended Deployment System).
s Provides unprecedented DO accuracy and longevity in
aggressive fouling environments
Figure 1. Profile of the new 6600 EDS depicting (clockwise from
bottom-right), Rapid PulseTM dissolved oxygen sensor, chlorophyll,
pH/ORP, and turbidity, all of which are maintained free of fouling
by the universal wiper assembly, as well as individual optical
wipers.
Figure 2. A prototype 6600 EDS after continuous deployment for
80 days in Buzzards Bay, MA. The sensor in the foreground is the
active DO sensor. The sensor at top-right was used as a non-wiped
fouling reference. Note extensive fouling by plant and animal
species on the non-wiped sensor.
s Wiped fouling protection for turbidity, chlorophyll, DO, pH,
and ORP sensors
s Ideal for extended, long-term deployments
s Virtually maintenance free
s Sensors are field-replaceable
s Integrates with DCPs
Initial field studies of the YSI 6600 EDS indicate that the system provides
unprecedented DO accuracy and longevity in aggressive fouling environments. The 6600 EDS was inspected after 80 days of an ongoing deployment performance evaluation (see Fig. 2). The Rapid PulseTM DO sensor
performed within specifications throughout this deployment without the
need for recalibration or cleaning. During this deployment, the instrument was removed once for battery replacement; none of the sensors
were cleaned or recalibrated.
6600 EDS 80 Day DO Performance Evaluation
Compatible with
EcoWatch™ for
Windows® software
Reference Measurement Dates
DO Conc mg/ l
Control DO mg/l
Figure 3. Remarkably close agreement (mean error 0.16mg/l) between the continuously deployed sonde and the control
measurements was observed throughout an 80-day deployment.
60
DO Quality Assurance for Wiped Do Study
Figure 4. DO measurements made continuously at
15-minute intervals for 80 days. Eight reference
measurements (blue symbols) were made during
this deployment. Data depicts excellent agreement
with reference measurements.
Control DO mg/l
DO mg/l
Time, Days
YSI 6600 EDS (Extended Deployment System)
Dissolved Oxygen
% Saturation
Range
Resolution
Accuracy
0 to 500%
0.1%
0 to 200%: ±2% of reading or 2% air saturation, whichever is greater;
200 to 500%: ±6% of reading
Dissolved Oxygen
mg/L
Range
Resolution
Accuracy
Conductivity †
Range
Resolution
Accuracy
0 to 50 mg/L
0.01 mg/L
0 to 20 mg/L: ±2% of reading or 0.2 mg/L, whichever is greater;
20 to 50 mg/L: ±6% of reading
0 to 100 mS/cm
0.001 to 0.1 mS/cm (range-dependent)
±0.5% of reading + 0.001 mS/cm
Temperature
Range
Resolution
Accuracy
pH
Range
Resolution
Accuracy
ORP
Range
Resolution
Accuracy
Salinity
Range
Resolution
Accuracy
-999 to +999 mV
0.1 mV
±20 mV
0 to 70 ppt
0.01 ppt
±1% of reading or 0.1 ppt, whichever is greater
Shallow Depth
Range
Resolution
Accuracy
0 to 30 feet (0 to 9 m)
0.001 feet (0.001 m)
±0.06 feet (±0.02 m)
Medium Depth
Range
Resolution
Accuracy
0 to 200 feet (0 to 61 m)
0.001 feet (0.001 m)
±0.4 feet (±0.12 m)
Deep Depth
Range
Resolution
Accuracy
Vented Level
Range
Resolution
Accuracy
0 to 656 feet (0 to 200 m)
0.001 feet (0.001 m)
±1 feet (±0.3 m)
0 to 30 feet (0 to 9 m)
0.001 feet (0.0003 m)
±0.01 feet (0.003 m)
Turbidity
Range
Resolution
Accuracy
Depth
0 to 1,000 NTU
0.1 NTU
±5% of reading or 2 NTU, whichever is greater
200 feet (60.96 m)
Chlorophyll
Range
Resolution
Depth
0 to 400 μg/L
0.1 μg/L Chl; 0.1%FS
200 feet (60.96 m)
-5 to +45°C
0.01°C
±0.15°C
0 to 14 units
0.01 unit
±0.2 unit
† Report outputs of specific conductance (conductivity corrected to 25° C), resistivity, and total dissolved solids are also provided.
These values are automatically calculated from conductivity according to algorithms found in Standard Methods for the
Examination of Water and Wastewater (ed 1989).
61
YSI 6500 Monitoring System
Compact, multiparameter
water quality system
provides continuous data
to improve the efficiency
of operations
Five ways you’ll stay one step ahead
1. Continuously monitor DO, conductivity, temperature, pH
By providing uninterrupted data, the YSI 6500 connected to a
YSI 6-Series sonde is a cost-effective alternative for water
quality monitoring. Replacing multiple instruments, it reduces
labor needs for both installation and operation.
Control the readout and
mode of operation
Make the characters small and read
all the parameters simultaneously.
Or use larger, easy-to-read
characters and view the parameters
two at a time.
2. Eight scalable 4-20 mA current loop channels
Monitor up to eight parameters with settable high and low
limits. You can integrate the YSI 6500 with SCADA or plant
control systems, and chart recorders.
3. Four SPDT relays
You define the setpoints for four parameters. Readings beyond
your setpoints trigger alarms or phone dialers.
4. Choose the calibration method you prefer
Loop output for transmitting
data to trigger alarms
4-20 mA
loop
output
DO, mg/L
control
relay
20
16
12
8
4
the YSI 6500 lets you calibrate in the field and the lab.
Easily calibrate the sensors with your PC and EcoWatch®
controlled and you’re out of the weather.
In the field, calibrate the DO sensor in air or use a YSI portable
oxygen meter (like the YSI 55) to determine calibration values;
use standard solutions to calibrate the pH and conductivity
probes.
8
7
6
5
4
3
on
off
t (hours)
you transmit data; the control
relays activate alarms and phone
control relay being activated when
the dissolved oxygen drops below
4 mg/L.
In the field, you can calibrate with the YSI 6500 Monitor itself,
a YSI 650 multiparameter display system, an Isco sampler or a
laptop computer.
5. Versatile YSI 600R adds flexibility to your operation
YSI 600r can be used independently for other applications,
such as stream sampling with a YSI 650 multiparameter display
system; or it can interface with an automatic sampler or flow
meter.
YSI 600r uses our Rapid Pulse™ oxygen sensor (no stirring
required) and the pH reference probe is replaceable.
62
System Components
YSI 6500 Monitor
Typical installations
YSI 600r sonde connected to a YSI
6500 monitor with a 25-foot YSI
6091 cable.
If you want to install the
monitor more than 25 feet from
the sonde, you must use a YSI 6502
breakout box in addition to your
own junction box and cable.
3.67”
4.11”
YSI 600R
system components.
1.00”
18.25”
4.11”
1.64”
2.25”
5.52”
YSI 6502 breakout box
4.00”
2.00” 4.40”
bulkhead
connector
mounting
flange kit
YSI 600R
9.69”
8.75”
8.40”
7.69”
6.83”
6.40”
YSI 6500
monitor
5.00”
5.13”
3.0” ±0.25”
MS-8
Mating
face
4.00” 6.40”
5.13”
6.0” ±0.25”
YSI 6507 patch cable
Red
Black
Purple
Overall cable assembly length = 72 +3/-0
0.75” conduit fitting
YSI 6505 weather shield
8.78”
6.25”
Mating
face
YSI 6091 BCR interconnect cable
9.00”
6.65” 4.25”
4 x .375 thru
2.16”
5.00”
MS-8
Mating
face
63
Overall cable assembly length = 25 feet
YSI 6500 Specifications
Operating Temperature
-20 to +60˚C (-4 to +140˚F)
Enclosure Rating
NEMA 4X
Line Power (nominal)
100 to 240 V AC, 50-60 Hz
Maximum Power Draw
45 watts
Control Relay Outputs
Rated 5 amps at 240 V AC
4 to 20 mA Loops
Class L, 0 to 300 ohms (250 ohms typical)
4 to 20 mA Output Accuracy
±0.08 mA (electrically isolated from sensors)
Electrical Safety
UL, CUL, and CE approved
Pollution Degree
II per UL3101
Installation Category
III per UL3101
YSI 600R Sensor Specifications
Range
Resolution
Accuracy
Dissolved Oxygen
% Saturation
Rapid Pulse™ Sensor
0 to 500%
0.1%
0 to 200%: ±2% of reading or 2% air
saturation, whichever is greater; 200 to 500%:
±6% of reading
Dissolved Oxygen
mg/L
Rapid Pulse™ Sensor
0 to 50 mg/L
0.01 mg/L
0 to 20 mg/L: ± 0.2 mg/L or 2% of reading,
whichever is greater; 20 to 50 mg/L: ±6% of
reading
Conductivityss
0 to 100 mS/cm
0.001 to 0.1 mS/cm
(range dependent)
±0.5% of reading + 0.001 mS/cm
Salinity
0 to 70 ppt
0.01 ppt
±1% of reading or 0.1 ppt, whichever is greater
Temperature
-5 to +50°C
0.01°C
±0.15°C
pH
0 to 14 units
0.01 unit
±0.2 unit
YSI 600R Sonde Specifications
Medium
Fresh, sea or polluted water
Software
Temperature
-5 to +50°C
Dimensions
Communications
RS-232, SDI-12
Power
64
EcoWatch®
Diameter
Length
Weight
1.65 in, 4.2 cm
14.8 in, 37.5 cm
1.10 lbs, 0.50 kg
External 12 V DC
6-Series Anti-Fouling Kits
System Inhibits Biofouling to Lengthen Deployment Times and
Reduce Operating Costs
and ensure high quality data for continuously deployed monitoring systems.
copper alloys to provide optimal anti-fouling characteristics and long-term
keep non-wiped surfaces slick and challenging for biofouling settlement.
times, a major savings in operating costs. With the Anti-fouling Kits installed, cleaning the sonde is much easier and the chance of damage during
cleaning is much less.
YSI 6600 sonde with installed
anti-fouling kit
t
t
t
t
Optimize data return from remote monitoring sites
Lower the cost of long-term deployments by 2-5x
200 meter depth rating for all Anti-Fouling Optical Probes
Easy instrument cleaning with lower risk of sensor damage
Refer to back page for list of all components.
Pure
Data for a
Healthy
Planet.®
representing a variety of freshwater and marine environments. In these challenging biofouling conditions, the materials which exhibited the best performance relative to durability and anti-fouling properties were selected for the
anti-fouling kits.
(Right) YSI sonde with anti-fouling
kit after 30 days deployed in a high
biofouling environment. The copper
anti-fouling kit significantly slowed
the growth of aquatic organisms on
the sensors.
Photo courtesy of Stephanie Hess, King County
65
How to Order Anti-fouling Parts
Category
Item Number Description
Optical
Sensors
616425
616431
616432
Optical Sensors, clockwise
6431,6425,and 6436
616436
616450
Anti-fouling Wiper
Wipers for
Sensors
616625*
616630*
6155 Membrane Kit
616445*
2166 Copper Screens
C-Spray Solution
6625AF Anti-fouling Wiper Kit for YSI optical sensors.**
Includes two wiper assemblies (copper-alloy wiper block,
larger pad, and setscrew), hex wrench, and instructions.
(Does not include sensor.)
6330AF Anti-fouling Wiper/Brush Kit for 6600EDS
sonde. Includes two wiper assemblies (copper-alloy wiper/
brush assembly, larger pad, and setscrew), hex wrench, and
instructions. (Does not include sensor.)
6445AF Anti-fouling Wiper/Brush Kit for 6600V2-4
sonde. Includes two wiper assemblies (copper-alloy wiper/
brush assembly, larger pad, and setscrew), hex wrench, and
instructions. (Does not include sensor.)
Membrane
606155
6155 Optical DO Membrane Kit for 6450 DO Probe. Includes copper-alloy replacement membrane, lock nuts, hex
wrench, and instructions. (Does not include sensor.)
Screen for
Sensors
202166
Copper-mesh screens. Includes two pre-formed, antifouling/animal blocking screens for 6560 Conductivity/
Temperature Probe and 6561 pH Probe.
Nanopolymer C-Spray
Solution
Guards
6175 Copper Sonde Guard Tape
Port Plugs
6189 Copper Tape
Anti-fouling Chlorophyll Probe. Includes probe with
copper-alloy housing, lock nut, wiper block, and wiper kit.
Rated to 200 meter depth.
Anti-fouling Blue-green Algae-Phycocyanin Probe.
Includes probe with copper-alloy housing, lock nut, wiper
block, and wiper kit. Rated to 200 meter depth.
Anti-fouling Blue-green Algae-Phycoerythrin Probe.
Includes probe with copper-alloy housing, lock nut, wiper
block, and wiper kit. Rated to 200 meter depth.
Anti-fouling Turbidity Probe. Includes probe with copperalloy housing, lock nut, wiper block, and wiper kit. Rated
to 200 meter depth.
Anti-fouling ROX Dissolved Oxygen Probe. Includes
probe with copper-alloy housing, lock nut, wiper block,
and wiper kit. Rated to 200 meter depth.
C-Spray Protective Probe Solution for 6560 Conductivity/
Temperature Probe and other components. 100 mL bottle.
616145
616176
616175
Copper-alloy sonde guard for 6600 sondes
Copper-alloy sonde guard for 6820/6920 sondes
Copper-alloy sonde guard for 600OMS sonde (long
length)
616189
Roll of anti-fouling copper tape
mm x 4.8 m). Adhesive backed. Apply to 6560 Conductivity/Temperature Probe, 6561 pH Probe, and other probes.
~230 applications. Lasts ~4-6 weeks in water.
616151
616161
616171
Copper-alloy optical probe port plug
Copper-alloy pH probe port plug
Copper-alloy ISE probe port plug
* Proper use of the anti-fouling wipers requires the latest version of 6-Series sonde firmware (3.06 or later).
** For a YSI 6600V2-4 sonde with wiped pH/ORP probe, purchase one 616445 wiper/brush assembly plus
616625 wipers for your remaining optical sensors. For a YSI 6600EDS sonde, purchase one 616630 wiper/
brush assembly plus 616625 wipers for your remaining optical sensors.
6151 Port Plug
66
Oil in Water Sensor Adapter Kit
Add Hydrocarbon Sensing to Existing Water Quality Sondes
and AUVs
output sensors. In addition to monitoring for the standard water quality parameters of
Temperature, Conductivity, pH, Dissolved Oxygen, Turbidity, Blue-Green Algae, and
Chlorophyll, 6-Series customers can now measure hydrocarbons and other parameters
from the Turner Cyclops-7® submersible sensor line.
Hydrocarbon monitoring in water is of growing importance near oil platforms, mari-
signal response.
YSI 6600 water quality sonde with adapted
Turner hydrocarbon sensor monitors oil in polluted
waters, shipping channels, and mines
By plugging the sensor adapter into an optical port on a YSI sonde, hydrocarbons can
tions. Because the Turner probe is seamlessly integrated into the YSI sensor suite,
hydrocarbon data are logged and transmitted along with water quality data.
Advantages
Field Upgradable:
sondes that may already be deployed. It provides the lowest-cost solution to adding
oil monitoring capability to current monitoring locations.
No Wiring:
power and logs data to its internal memory. If the sonde is already connected to a data
logger, then the logger program will only require a slight change to accept additional
output parameters over SDI-12.
CDOM Rejection: Separating the oil signal from naturally occurring Colored Dissolved Organic Matter is a strength of the Turner probes, which give the maximum
signal with minimal interference. A C7 CDOM sensor can also be added if another
sensor adapter is purchased.
Compatibility
6920, 6820, and OMS, will require external power and a customized sensor guard
Adapter Kit is compatible with YSI’s EMM68 rapid deployment harbor buoy.
Note:
a quote on special fabrications.
67
Oil in Water Sensor Adapter Kit Includes:
Adapter
Sensors
Accessories
YSI-Turner C7 Adapter Module with sonde interface connector,
wet-pluggable C7 connector, and microprocessor controller
202400
One of the following Turner sensor options:
202401
202402
202403
Crude oil sensor for open ocean monitoring
CDOM sensor for coastal monitoring
Extended 14 in. plastic sensor guard without bottom plate
Extended transport and calibration cup without endcap and gasket
202414
202415
Firmware upgrade to add auxiliary ports 1 and 2 parameter selection in the
Sensor Menu, and millivolts and engineering units in the Report Menu
Firmware
Instructions
Installation and calibration instructions
202416
Sensor Specifications:
Near-Shore Refined Fuels Sensor with CDOM Rejection
Min. Detection Limit
2 ppb NS (1.5 Napthalene Disulfonic Disodium Salt)
Range
0-10,000 ppb NS (1.5 Napthalene Disulfonic Disodium Salt)
Sensor Output (AUX)
0-5 V
Linearity
0.99 R2
Depth
61 meters
Temperature Range
0-50 deg C
Open-Water Crude Oil Detection Sensor
Min. Detection Limit
0.2 ppb QS (Quinine Sulfate)
Range
0-1,500 ppb QS (Quinine Sulfate)
Sensor Output (Aux)
0-5 VDC
Linearity
0.99 R2
Depth
61 meters
Temperature Range
0-50 deg C
CDOM Sensor
Min. Detection Limit
Range
Sensor Output (Aux)
Linearity
Depth
Temperature Range
0.4 ppb QS (Quinine Sulfate)
0-2,500 ppb QS (Quinine Sulfate)
0-5 VDC
0.99 R2
61 meters
0-50 deg C
68
EMM68 Buoy
Quick and Easy Access to Water Quality Data
water quality monitor-
ing
by two people, reducing deployment and maintenance costs—while
And the
entire system can be installed without divers, allowing for complete
economical alternative to obtaining site access to install permanent
Receive remote data
Two data delivery systems are available to send data from any YSI
The EMM68 buoy is lightweight and
easy to deploy from shore or small boat
while the web-enabled option posts data directly to a public or private
web site.
Advantages of remote data delivery:
t
t Make you aware of changing conditions as they occur, improving
response time
t Match your calibration and maintenance schedules to actual sensor
performance, reducing consumables
EMM68 buoy supports a single water
quality instrument, such as a YSI 6600
V2-4 sonde, positioned inside the
subsurface pipe
Ideal for monitoring in these applications
t Baseline studies
t Construction and dredging
t Dye-tracing studies
t Emergency response
t Fisheries
t Industrial sites
t Non-point source/TMDL
t Point source/discharge
t Stormwater & CSO
t Source water
t University/research
Custom systems available
Contact YSI’s Integrated Systems & Services division to discuss your
deployment in high-energy environments and for long-term monitoring
projects.
69
EMM68 Buoy Specifications
Weight
Mooring
Antenna
Solar
Battery
Float
Sensor Payload
48 kg (105 lbs) in air
Customer-supplied single- or two-point
Integral cellular antenna standard; waterproof external antenna optional
2 x 10-watt panels
12 v/24 amp-hr
Any YSI 6-Series water quality sonde (can include temperature, depth,
conductivity, blue-green algae, chlorophyll, dissolved oxygen, ORP, pH,
rhodamine, and turbidity)
Software
Telemetry
Beacon
Deployment
separately
CDMA through Verizon®, GSM circuit-switched data, or GPRS (customer
Flashing amber; optional
Min. water depth 1.8 meters; max. operational currents 2 knots;
max. rolling wave height 1 meter
Simple Steps to Deploy a Buoy
t Activate cellular modem and account
t
unrestricted internet access
t
t Test communications in lab
t Source and install mooring lines and weights
t Deploy buoy in safe location
t Maintain sensors and equipment on a
regular basis
70
EMM350 PISCES Platform
Pontoon for In-situ Characterization of Environmental Systems
ity, water velocity, and meteorological sensors as well as computer logging
serviceable from the water and accommodate multiple underwater cable
connections.
platform provides several instrument array options as well as several data
acquisitions products.
Features include:
t Towable by most small vessels
t Ideal for high currents up to 12 knots
t Loading and deployment by two persons
Pure
Data for a
Healthy
Planet.
®
t Abundant power reserve and solar accumulation
t
t Sonde standpipe is retractable for transportation and towing
multiple-depth sampling
Custom systems available
Easily movable monitoring
platform for navigable
waterways
The PISCES is deployed with one- or two-point mooring, making it
stable even in wind-driven surface chop.
71
EMM350 Specifications
Hull
Weight
Shape
Dimensions
160 lbs.; with payload 230 lbs.
Catamaran
Height 70 in.
Length 75 in.
Width 48 in.
Mooring Attachment
One- or two-point attachment points
Frame
6061 marine-grade, powder-coated aluminum
6061 marine-grade, powder-coated aluminum
316 stainless steel
Tripod
Hardware
Antenna
Beacon
Solid-state LED strobe
Sonde Tube
Left: EMM350 is designed to fit between
the wheel wells of a full-size pickup truck.
The EMM350 is easy to deploy for moni toring around construction, dredging, and
other applications.
®
72
vertical profiling
for continuous monitoring
Simultaneously monitor water quality, water velocity, and
meteorological data 24/7 with an automated Vertical Profiling System,
the most comprehensive environmental monitoring system available.
Why Profile?
Source Water Monitoring
Water quality assessment
is best conducted through
a complete time series that
monitors physical,
chemical, and biological
parameters.
YSI’s automated Vertical
Profiler offers further
advancements by sampling
at different depths, allowing you to monitor an entire
water column.
Variations in temperature,
wind, rainfall, salinity, and
flow cause changes in the
vertical structure of a water
column, varying from highly
stratified to well-mixed.
19-20˚C
18-19˚C
sonde collects water quality
data at uniform steps
throughout the water column
17-18˚C
data are used to
identify which intake
is closest to the best
water quality
16-17˚C
Users who apply data from
a Vertical Profiler will see
the impacts of the physical
environment on their water
resources—without frequent
trips to the field.
15-16˚C
14-15˚C
A Vertical Profiler is moored
next to a water intake tower in a drinking
water reservoir. Profiler data are used to
continuously assess water quality, allow ing a plant manager to select the most
appropriate intake.
73
Vertical Profiling Systems
Comprised of three components: 1) a floating or fixed mounting platform, 2) a profiling package
composed of a controller, winch, data logging and telemetry system, and meteorological sensor
suite (optional), and 3) an underwater sensor package that typically includes a YSI 6-Series water
quality sonde and other sensors upon request.
YSI 6950 Fixed Profiling System YSI 6951 Pontoon-Mounted Profiling System
can be attached to any fixed with meteorological package provides a stable
work surface and easy-to-deploy design for
structure such as a bridge or pier
low-energy environments
YSI 6952 Buoy-Based Profiling System for
high-energy environments
Anti-fouling technology
Adjust profile steps
Integrated wipers and new
copper-alloy Anti-Fouling Kits
for YSI sensors prevent the
growth of biofouling, prolong
maintenance intervals, lower
operating costs, and improve
reliability.
As water levels fluctuate,
data from optional fixed
reference sonde or optional
depth sounder automatically
compensate for the changes.
Alternately, a 50-point table
entry may be used.
Vertical Profiling System Specifications
Minimum Profile Depth
1 meter
Maximum Profile Depth
100 meters
Depth Profile Setpoint Accuracy
Recommended/Min. Step Size
1 meter/0.5 meter
Maximum Profile Frequency
~50% of duty cycle
Sensor Options
Water Quality: Conductivity, temperature, depth, dissolved oxygen,
pH/ORP, turbidity, chlorophyll a, blue-green algae, PAR, and velocity
Meteorological: Wind speed and direction, barometric pressure, rainfall,
relative humidity, light, and air temperature
Sensor Step Modes
Table entry (50 steps max.) or computed
Power Requirement
Cable Options
15 meter vented, 50 meter, or 100 meter
74
The CastAway™-CTD
with profiling and analysis software
TheYSI CastAway-CTD is a lightweight,easy
to use hydrographic instrument designed
for quick and accurate conductivity,
temperature, and depth profiles. Starting
with a unique six-electrode array and a
flow-through cell, the CastAway makes
use of commercial Bluetooth and GPS
technology to make an instrument that is as
usable as it is accurate.
The palm-sized CastAway-CTD can easily
be deployed by hand. Each cast is referenced
with both time and location using its builtin GPS receiver. Latitude and longitude
are acquired both before and after each
profile. Plots of conductivity, temperature,
salinity and sound speed versus depth can
be viewed immediately on the CastAway’s 4HE #ASTAWAY IS A MULTI-FUNCTIONAL TOOL THAT
integrated color LCD screen in the field. INCORPORATES THE MOST MODERN TECHNOLOGY AVAILABLE
- YET IS SIMPLE TO USE. )T IS DESIGNED FOR #4$
PROlLING DOWN TO l00 M AND IS EASY TO DEPLOY.
Raw data can be easily downloaded via
Bluetooth to a Windows computer for
detailed analysis and/or export at any time. Rugged, non-corrosive housing, AA battery
power and tool-free operation reflect the technician-friendly pedigree of the CastAwayCTD. So do the simple, intuitive features – everything an operator needs to know
about deploying the CastAway-CTD, viewing data and downloading the files fits in the
lunchbox-sized carrying case.
Best used in:
s Coastal Oceanography
s Hydrology
s Aquaculture/Fisheries
When needed for:
s Saltwater Intrusion
s Surveying/Hydrography
s Sound Velocity Profiles
s &Ield Sensor Verification
s %STUArine Research
The CastAway-CTD
Instant, reliable data in the
palm of your hand!
s '03 POSITION1 DATE AND TIME
s &AST SAMPLING AND SENSOR RESPONSE
s WATERPROOF INTERFACE WORKS IN AND OUT OF THE WATER
s "LUETOOTH WIRELESS COMMUNICATION
s .O USER CALIBRATION REQUIRED
s .O TOOLS1 COMPUTERS OR CABLES REQUIRED!
75
Specifications
Memory 15 MB (750+ casts based on typical usage)
Communications Bluetooth class II, up to 10 m range
Power 2 “AA” alkaline batteries, 40 hours continuous use
Simple “AA”
battery installation
and storage area
for spare stylus.
Data Output Format - ASCII (CSV)
-Hypack
-Matlab
Environmental - Depth range: 0-100 m
- Use temperature: -5° to 45° C
- Storage temperature: -10° to 50° C
Sampling Modes - Casting (up/down)
- Point sample (moving the unit back and forth)
Software - Windows XP/Vista/7
- Geo-referenced
- Multi-language
- Data plots, filtering, import/export
Accessories - Hard plastic storage/shipping case
- Polyurethane jacket
- 15m deployment line
- Bluetooth dongle
- Two locking carabiners
- Three magnetic stylus pens
- Cleaning brush
A screen capture of data from a
river delta in Louisiana acquired
using a CastAway-CTD. The
technicians collected 21 casts in
less than 3.5 hours.
Thermistor Response Less than 200 ms
Sampling Rate 5 Hz
Weight In air: 1.0 lb (0.45 kg)
In water: 0.06 lbs (0.03 kg)
Each CastAway ships in this hard
plastic kit, complete with
accessories and quick start guide.
The CastAway-CTD Output Parameters
Range
Resolution
Accuracy
Measured or Derived
Conductivity
0 to 100,000 μS/cm
1μS/cm
± 0.25% ± 5 μS/cm
Measured
Temperature
-5° - 45° C
0.01° C
± 0.05° C
Measured
Pressure
0 to 100 dBar
0.01 dBar
± 0.25% FS
Measured
Salinity
Up to 42 (PSS-78)
0.01 (PSS-78)
± 0.1 (PSS-78)
PSS-783
Sound Speed
1400 - 1730 m/s
0.01 m/s
± 0.15 m/s
Chen-Millero4
Density1
990 to 1035 kg/m3
0.004 kg/m3
± 0.02 kg/m3
EOS805
0 to 100 m
0.01m
± 0.25% FS
EOS805
0 to 250,000 μS/cm
1μS/cm
± 0.25% ±5 μS/cm
EOS805
Depth
Specific Conductivity
2
10 m
GPS
Based on temperature resolution and accuracy.
2
Based on 100,000 μS/cm at -5° C.
3
1978 Practical Salinity Scale.
4
Chen-Millero, 1977. Speed-of-sound in sea water at high pressures.
5
International Equation of State for sea water (EOS-80).
1
76
NEW
AUV
Generate High-Resolution Maps of Water Quality and Bathymetry
AUV (Autonomous Underwater Vehicle) with YSI’s 6-Series sensors will provide
continuous interval for missions up to 10 hours long.
t UnderwateS vehiclF iT easilZ deployeE bZ oOF person
surveZ desigO aOE execution
t UndulatioO througI tIF wateS columO providFT datB JO
botI tIF IorizontaM aOE verticaM planeT
t Geo-referenceE data
t ProveO YS* sensoS technology
EcoMapper Platform
t Robust and simple to use – minimal operator training
t Low cost of ownership – purchase, maintain, repair,
modify
t Bow with integrated sensor package includes YSI’s
sensor bulkhead, depth sounder, and PAR ports
t
aluminum construction
t Launch from the shore or small boat
t Li-Ion batteries = long run-time and quick recharge
t Near-coastal operating depth — bays, rivers, lakes
Once deployed, the EcoMapper communicates with a Wi-Fi box while on the surface
(up to 200 m) and acquires a GPS fix at
waypoints identified in the mission plan.
Between waypoints, the EcoMapper dives
to a specified depth and dead reckons to
the next waypoint.
Pure
Data for a
Healthy
Planet.
®
Automated Water
Quality Surveys
t GPS (WAAS) position-corrected data at 1 Hz rate
t Built-in moisture detectors with fail-safe emergency buoyancy system for
asset recovery
t Integrated location pinger
Water Quality Parameters
Temperature
Conductivity
ROX™ Optical Dissolved Oxygen
Turbidity
Chlorophyll
Blue-Green Algae (marine or freshwater)
Rhodamine
Depth
PAR - Upward-facing
PAR - Downward-facing
Salinity
Resistivity
TDS
TSS
pH
ORP
77
Mission planning software with an intuitive interface
t Simple to use waypoint-based navigation and mission planning
t Select any NOAA or USGS Chart in GEO/NOS format (even geo-referenced satellite images)
t Operator selects measurement depths, speed, sensors, poling frequency, etc.
t
t
t
Screenshot from VectorMap mission
planning software showing a “lawnmower”style mission path drawn onto image of
saltwater lagoon.
Place the vehicle in the water and start
mission.
Dissolved oxygen data collected from
saltwater lagoon mission.
Salinity map of lagoon. Notice the
freshwater input in the northwest corner.
EcoMapper AUV Specifications
Dimensions
Diameter
Length
Weight
5.8 in, 14.73 cm
60.1 in, 152.6 cm
45 lbs, 20.4 kg
Propulsion System
2-blade cast bronze propeller
Endurance
8 hours at speed of 2.5 knots
Speed Range
1-4 knots
Control
Four independent control planes
External Hook-up
Data: wireless 802.11g Ethernet (up to 200 m comm. distance)
Power: 2-pin DC charge voltage in
Navigation
Tracking
Internal data log; programmable resolution
Software
Energy
600 WHrs of rechargeable Lithium-Ion batteries (>300 cycles)
Onboard Electronics
Low power X86 processor; 80 GB disk drive for data collection
Communication
2.4 GHz radio link when on the surface to download missions and upload collected data
Option
Imagenex side-scan sonar 330 kHz
78
79
80
81
82
Measure and Visualize Oxygen Distributions in 2D
For Biological Research
83
84
Hoskin Scientific Limited has been supplying testing and
monitoring instruments since 1946. Although our range is
broad, we focus on three major markets including:
Geotechnical & Materials Testing
Environmental Monitoring
Test & Measurement Instrumentation
Hoskin Scientific operates out of three offices within Canada:
3735 Myrtle Stree,t
Burnaby, BC V5C 4E7
Phone (604) 872-7894
Fax (604) 872-0281
email [email protected]
800-663-3023
4210 Morris Drive,
Burlington, ON L7L 5L6
Phone (905) 333-5510
Fax (905) 333-4976
email [email protected]
800-247-3581
300 Rue Stinson,
Montreal, PQ H4N 2E7
Phone (514) 735-5267
Fax (514) 735-3454
email [email protected]
02.15
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement