40GJ*B
40GJ*B
F
4
1
Volt-Ph
Unit Tons
Unit Btuh
Indoor Model Number
0.75
9,000
208/230-1
40GJQB09B--3
1
12,000
208/230-1
40GJQB12B--3
1.5
18,000
208/230-1
40GJQB18B--3
2
24,000
208/230-1
40GJQB24B--3
@ 60Hz
Parts Name
Indoor Unit
air inlet
panel
filter
aux.button
horizontal louver
cooling
indicator
power
indicator
air outlet
receiver
window
display
F
heating
indicator
temp.
indicator
drying
indicator
(Display content or position may be different from above
graphics, please refer to actual products)
remote controller
Notice:
Actual product may be different from above graphics, please refer to actual
products.
Working temperature range
Operating Temperature Range(Optional)
o
o
Indoor side DB/WB( F/ C)
o
o
Outdoor side DB/WB( F/ C)
Maximum cooling
89.6/73.4(32/23)
118.4/-(48/-)
Maximum heating
80.6/-(27/-)
75.2/64.4(24/18)
o
o
The operating temperature range (outdoor temperature) for cooling only unit is -0.39 F (-18 ) ~118.4 F (48 );
for heat pump unit is -5 F (15 ) ~118.4 F (48 ).
o
o
2
How to use the remote control to operate the unit
OPERATION INSTRUCTIONS
Remote Controller Description
ON/OFF
1
Press it to start or stop operation.
- : Press it to decrease temperature
2
setting.
+ : Press it to increase temperature
3
setting.
MODE
4
Press it to select operation mode
(AUTO/COOL/DRY/FAN/HEAT).
F
FAN
5
Press it to set fan speed.
1
6
SWING
Press it set swing angle.
3
2
I FEEL
7
/
8
(This function is only applicable for some models.)
Press it to set HEALTH or AIR function.
4
5
9
SLEEP
6
7
10
TEMP
8
9
11
QUIET
10
11
12
13
14
15
16
Press it to set QUIET function.
12
CLOCK
Press it set clock.
13
72172))
Press it to set auto-off/auto-on timer.
14
TURBO
15
LIGHT
Press it to turn on/off the light.
16
3
X-FAN
How to use the remote control to operate the unit
OPERATION INSTRUCTIONS
Remote Controller Description
1 ON/OFF :
Press this button to turn on the unit .Press this button again to turn off the unit.
2
Press this button to decrease set temperature. Holding it down above 2 seconds rapidly
decreases set temperature. In AUTO mode, set temperature is not adjustable.
3
+:
Press this button to increase set temperature.Holding it down above 2 seconds rapidly
increases set temperature. In AUTO mode, set temperature is not adjustable.
4 MODE :
Each time you press this button,a mode is selected in a sequence that goes from AUTO,
COOL,DRY, FAN,and HEAT *, as the following:
AUTO
COOL
DRY
FAN
HEAT
*
*Note:Only for models with heating function.
After energization, AUTO mode is defaulted. In AUTO mode, the set temperature will not
be displayed on the LED of the indoor, and the unit will automatically select the suitable operation
mode in accordance with the room temperature to make indoor room comfortable.
5 FAN :
This button is used for setting Fan Speed in the sequence that goes from AUTO,
, then back to Auto.
,
,
to
,
Auto
Low speed
Low-Medium speed
Medium speed
Medium-High speed
6
High speed
SWING:
Press this button to set up &down swing angle, which circularly changes as below:
OFF
This remote controller is universal . If any command
the unit will carry out the command as
,
or
is sent out,
indicates the guide louver swings as:
7 I FEEL:
Press this button to turn on I FEEL function. The unit automatically adjust temperature
according to the sensed temperature. Press this button again to cancel I FEEL function.
4
How to use the remote control to operate the unit
8
9
OPERATION INSTRUCTIONS
/
Press this button to achieve the on and off of healthy and scavenging functions in operation status.
Press this button for the first time to start scavenging function;
LCD displays“ ”. Press the button for the second time to start healthy and scavenging functions
simultaneously; LCD displays“ ” and “ ” . Press this button for the third time to quit healthy
and scavenging functions simultaneously. Press the button for the fourth time to start healthy
function; LCD display “
” . Press this button again to repeat the operation above.
SLEEP:
Press this button, can select Sleep 1 (
), Sleep 2 (
),Sleep 3 (
) and cancel the Sleep,
circulate between these, after electrified, Sleep Cancel is defaulted.
Sleep 1 is Sleep mode 1, in Cool, Dehumidify modes: sleep status after run for one hour, the main
unit setting temperature will increase 1.8 ℉ (1 ℃) ,setting temperature increased 3.6 ℉ (2℃) , the unit will run at this
setting temperature; In Heat mode: sleep status after run for one hour, the setting temperature will
decrease 1.8 ℉ (1 ℃) , 2 hours, setting temperature will decrease 3.6 ℉ (2℃) , then the unit will run at this setting
temperature.
Sleep 2 is sleep mode 2, that is air conditioner will run according to the presetting a group of sleep temperature curve.
Sleep 3- the sleep curve setting under Sleep mode by DIY:
(1) Under Sleep 3 mode, press "Turbo" button for a long time, remote control enters into user individuation sleep
setting status, at this time, the time of remote control will display "1 hour ", the setting temperature "88" will
display the corresponding temperature of last setting sleep curve and blink (The first entering will display
according to the initial curve setting value of original factory);
(2) Adjust "+" and "-" button, could change the corresponding setting temperature, after adjusted, press
"Trubo "button for confirmation;
(3) At this time, 1 hour will be automatically increased at the timer postion on the remote control, (that are
"2 hours " or "3 hours " or "8 hours "), the place of setting temperature "88" will display the
corresponding temperature of last setting sleep curve and blink;
(4) Repeat the above step (2)
(3) operation, until 8 hours temperature setting finished, sleep
curve setting finished, at this time, the remote control will resume the original timer display;
temperature display will resume to original setting temperature.
Sleep3- the sleep curve setting under SLEEP mode by DIY could be inquired:
The user could accord to sleep curve setting method to inquire the presetting sleep curve, enter into user
individuation sleep setting status, but do not change the temperature, press "Turbo" button directly for confirmation.
Note: In the above presetting or enquiry procedure, if continuously within10s, there is no button pressed, the
sleep curve setting within10s, there is no button pressed, the sleep curve setting status will be automatically
quit and resume to display the original displaying. In the presetting or enquiry procedure, press "ON/OFF"
button, "Mode" button, "Timer"button or "Sleep" button, the sleep curve setting or enquiry status will quit similarly.
10 TEMP:
Press this button, could select displaying the indoor setting temperature or indoor ambient
temperature.When the indoor unit firstly power on it will display the setting temperature,
if the temperature's displaying status is changed from other status to" ",displays the
ambient temperature, 5s later or within 5s, it receives other remote control signal that will
return to display the setting temperature. if the users haven't set up the temperature
displaying status,that will display the setting temperature.
5
How to use the remote control to operate the unit
OPERATION INSTRUCTIONS
11 QUIET:
Press this button, the Quiet status is under the Auto Quiet mode (display " " and "Auto" signal)
and Quiet mode (display "
" singal) and Quiet OFF (there is no signal of "
" displayed),
after powered on, the Quiet OFF is defaulted. Note: the Quiet function cannot be set up in Fan
and Dry mode;Under the Quiet mode (Display "
" signal), the fan speed is not available.
12 CLOCK :
Press CLOCK button, blinking
. Within 5 seconds,pressing +or - button adjusts the
present time.Holding down either button above 2 seconds increases or decreases the
time by 1 minute every 0.5 second and then by 10 minutes every 0.5 second. During
blinking after setting, press CLOCK button again to confirm the setting,and then
will be constantly displayed.
13
T-ON T-OFF:
Press T-ON button to initiate the auto-ON timer. To cancel the auto-timer program, simply
press this button again.
After press of this button,
disappears and "ON "blinks .00:00 is displayed for ON time
setting. Within 5 seconds, press + or - button to adjust the time value. Every press of either
button changes the time setting by 1 minute. Holding down either button rapidly changes the
time setting by 1 minute and then 10 minutes. Within 5 Seconds after setting, press TIMER
ON button to confirm.
Press T-OFF button to initiate the auto-off timer. To cancel the auto-timer program, simply
press the button again.TIMER OFF setting is the same as TIMER ON.
14 TURBO:
Press this button to activate / deactivate the Turbo function which enables the unit to
reach the preset temperature in the shortest time. In COOL mode, the unit will blow strong
cooling air at super high fan speed. In HEAT mode, the unit will blow strong heating air
at super high fan speed.
15 LIGHT:
Press LIGHT button to turn on the display's light and press this button again to turn off
the display 's light. If the light is turned on ,
is displayed. If the light is turned off,
disappears.
16 X-FAN:
Pressing X-FAN button in COOL or DRY mode,the icon
is displayed and the indoor
fan will continue operation for 10 minutes in order to dry the indoor unit even though you
have turned off the unit.
After energization, X-FAN OFF is defaulted. X-FAN is not available in AUTO,FAN or
HEAT mode.
17 Combination of "+" and "-" buttons: About lock
Press "+ " and "-" buttons simultaneously to lock or unlock the keypad. If the remote
controller is locked,
is displayed. In this case, pressing any button,
three times.
6
blinks
How to use the remote control to operate the unit
OPERATION INSTRUCTIONS
18 Combination of "MODE " and "-" buttons : About switch between Fahrenheit and centigrade
At unit OFF, press "MODE " and "- " buttons simultaneously to switch between
and
.
19 Combination of " TEMP " and "CLOCK" buttons : About Energy-saving Function
Press “TEMP” and “CLOCK” simultaneously in COOL mode to start energy-saving function.
Nixie tube on the remote controller displays “SE”. Repeat the operation to quit the function.
20 Combination of " TEMP " and "CLOCK" buttons : About 46 ℉ (8 ℃) Heating Function
Press “TEMP” and “CLOCK” simultaneously in HEAT mode to start 46 ℉ (8 ℃) Heating Function
Nixie tube on the remote controller displays “ ” and a selected temperature of “ 46 ℉ (8 ℃) ”.
Repeat the operation to quit the function.
21 About Back-lighting Function
The unit lights for 4s when energizing for the first time, and 3s for later press.
Replacement of Batteries
1.Remove the battery cover plate from the rear of the remote controller.
(As shown in the figure)
2.Take out the old batteries.
3.Insert two new AAA1.5V dry batteries, and pay attention to the polarity.
4. Reinstall the battery cover plate.
Notes:
When replacing the batteries, do not use old or different types of batteries,
otherwise, it may cause malfunction.
If the remote controller will not be used for a long time, please
remove batteries to prevent batteries from leaking.
The operation should be performed in its receiving range.
It should be kept 3.28ft (1 m) away from the TV set or stereo sound sets.
If the remote controller does not operate normally, please take the
batteries out and reinsert them after 30 seconds.If it still can't operate properly,
replace the batteries.
7
Sketch map for
replacing batteries
Emergency operation
If remote controller is lost or damaged, please use auxiliary button to turn
on or turn off the air conditioner. The operation in details are as below:
air conditioner. When the air conditioner is turned on, it will operate under
auto mode.
panel
aux. button
Clean and Maintenance
Note:
Ŷ Turn off the air conditioner and disconnect the power before cleaning the air
conditioner to avoid electric shock.
Ŷ'RQRWZDVKWKHDLUFRQGLWLRQHUZLWKZDWHUWRDYRLGHOHFWULFVKRFN
Ŷ'RQRWXVHYRODWLOHOLTXLGWRFOHDQWKHDLUFRQGLWLRQHr.
Clean surface of indoor unit
When the surface of indoor unit is dirty, it is recommended to use a soft dry cloth
or wet cloth to wipe it.
Note:
Ɣ'RQRWUHPRYHWKHSDQHOZKHQFOHDQLQJLW
8
Clean and Maintenance
1
Open panel
3
Pull out the panel to a certain
Ɣ8VHGXVWFDWFKHURUZDWHUWR
WKHZDWHUEHORZć℉)
WRFOHDQLWDQGWKHQSXWLWLQ
DVKDG\DQGFRROSODFHWRGU\
.
2
4
panel cover tightl\.
Note:
operation environment, clean frequenc\FDQEHLQFUHDVHG
9
Clean and Maintenance
Checking before use-season
1. Check whether air inlets and air outlets are blocked.
2. Check whether circuit break, plug and socket are in good condition.
4. Check whether drainage pipe is damaged.
Checking after use-season
1. Disconnect power supply.
Notice for recovery
1. Many packing materials are recyclable materials.
Please dispose them in appropriate recycling unit.
2. If you want to dispose the air conditioner, please contact local dealer or
consultant service center for the correct disposal method.
10
Malfunction analysis
General phenomenon analysis
Please check below items before asking for maintenance. If the malfunction still
FDQ¶WEHHOLPLQDWHGSOHDVHFRQWDFWORFDOGHDOHURUTXDOL¿HGSURIHVVLRQDOV
Phenomenon
Check items
Solution
Ɣ:KHWKHULW
VLQWHUIHUHGVHYHUHO\ Ɣ3XOORXWWKHSOXJ5HLQVHUW
(such as static electricity, stable the plug after about 3min, and
voltage)?
then turn on the unit again.
Indoor unit
can’t receive
remote
controller’s
signal or
remote
controller
has no
action.
Ɣ:KHWKHUUHPRWHFRQWUROOHULV
within the signal receiving
range?
Ɣ6LJQDOUHFHLYLQJUDQJHLVP
Ɣ:KHWKHUWKHUHDUHREVWDFOHV"
Ɣ5HPRYHREVWDFOHV
ƔSelect proper angle and point
Ɣ:KHWKHUUHPRWHFRQWUROOHULV
pointing at the receiving
the remote controller at the rewindow?
ceiving window on indoor unit.
Ɣ,VVHQVLWLYLW\RIUHPRWHFRQWUR Ɣ&KHFNWKHEDWWHULHV,IWKH
power of batteries is too low,
OOHUORZIX]]\GLVSOD\DQGQR
please replace them.
display?
Ɣ&KHFNZKHWKHUUHPRWHFRQW
Ɣ1RGLVSOD\ZKHQRSHUDWLQJ
roller appears to be damaged.
remote controller?
If yes, replace it.
Ɣ)OXRUHVFHQWODPSLQURRP"
No air
emitted
from
indoor
unit
Ɣ7DNHWKHUHPRWHFRQWUROOHU
close to indoor unit.
Ɣ7XUQRIIWKHÀXRUHVHQWODPS
and then try it again.
Ɣ$LULQOHWRUDLURXWOHWRILQGRRU
unit is blocked?
Ɣ(OLPLQDWHREVWDFOHV
Ɣ8QGHUKHDWLQJPRGHLQGRRU
temperature is reached to set
temperature?
Ɣ$IWHUUHDFKLQJWRVHWWHPSHU
ature, indoor unit will stop blowing out air.
Ɣ+HDWLQJPRGHLVWXUQHGRQMXVW Ɣ,QRUGHUWRSUHYHQWEORZLQJ
now?
out cold air, indoor unit will be
started after delaying for several minutes, which is a normal phenomenon.
11
Malfunction analysis
Phenomenon
Air conditioner can’t
operate
Mist is emitted from
indoor unit’s
air outlet
Set temperature can’t
be adjusted
Cooling
(heating)
effect is
not good.
Check items
Solution
Ɣ3RZHUIDLOXUH"
Ɣ:DLWXQWLOSRZHUUHFRYHU\
Ɣ,VSOXJORRVH"
Ɣ5HLQVHUWWKHSOXJ
Ɣ$LUVZLWFKWULSVRIIRUIXVHLV
burnt out?
Ɣ$VNSURIHVVLRQDOWRUHSODFH
air switch or fuse.
Ɣ:LULQJKDVPDOIXQFWLRQ"
Ɣ$VNSURIHVVLRQDOWRUHSODFHLW
Ɣ8QLWKDVUHVWDUWHGLPPHGLDWHO\
Ɣ:DLWIRUPLQDQGWKHQWXUQ
after stopping operation?
on the unit again.
Ɣ:KHWKHUWKHIXQFWLRQVHWWLQJ
for remote controller is
correct?
Ɣ5HVHWWKHIXQFWLRQ
Ɣ,QGRRUWHPSHUDWXUHDQGKXP
idity is high?
Ɣ%HFDXVHLQGRRUDLULVFRROHG
rapidly. After a while, indoor
temperature and humidity will
be decrease and mist will
disappear.
Ɣ8QLWLVRSHUDWLQJXQGHUDXWR
mode?
Ɣ7HPSHUDWXUHFDQ¶WEHDGMX
sted under auto mode.
Please switch the operation
mode if you need to adjust
temperature.
Ɣ<RXUUHTXLUHGWHPSHUDWXUH
exceeds the set temperature
range?
Ɣ6HWWHPSHUDWXUHUDQJH
16ć ~30ć(61℉-86℉) .
Ɣ9ROWDJHLVWRRORZ"
Ɣ:DLWXQWLOWKHYROWDJH
resumes normal.
Ɣ)LOWHULVGLUW\"
Ɣ&OHDQWKH¿OWHU
Ɣ6HWWHPSHUDWXUHLVLQSURSHU
range?
Ɣ$GMXVWWHPSHUDWXUHWRSURSHU
range.
Ɣ'RRUDQGZLQGRZDUHRSHQ"
Ɣ&ORVHGRRUDQGZLQGRZ
12
Malfunction analysis
Phenomenon
Check items
Solution
Odours are
emitted
Ɣ:KHWKHUWKHUH’s odour source, Ɣ(OLPLQDWHWKHRGRXUVRXUFH
such as furniture and cigarette,
etc.
Air conditioner operates
abnormally
Ɣ:KHWKHUWKHUH’s interference,
such as thunder, wireless
devices, etc.
“:ater
noise
Cracking
noise
Ɣ'LVFRQQHFWSRZHr, put back
power, and then turn on the
unit again.
Ɣ The noise is the sound of
Ɣ Air conditioner is turned on or
turned off just now?
Ɣ Air conditioner is turned on or
turned off just now?
13
the unit, which is a normal
phenomenon.
Ɣ This is the sound of friction
caused by expansion and/or
contraction of panel or other
parts due to the change of
temperature.
Malfunction analysis
Error Code
Ɣ:KHQDLUFRQGLWLRQHUVWDWXVLVDEQRUPDlWHPSHUDWXUHLQGLFaWRURQLQGRRUXQLWZLOO
DWLRQRIHUURUFRGH
,QGRRU
GLVSOD\
(UURUFRGH
$ERYHLQGLFDWRUGLDJUDPLVRQO\
IRUUHIHUHQFH3OHDVHUHIHUWR
DFWXDOSURGXFWIRUWKHDFWXDO
LQGLFDWRUDQGSRVLWLRQ
(UURUFRGH
TURXEOHVKRRWLQJ
+HDWLQJLQGLFDWRU
21V2))V
0HDQVGHIURVWLQJVWDWXV,W¶VWKHQRUPDOSKHQRPHQRQ
)
3OHDVHFRQWDFWTXDOLILHGSURIHVVLRQDOVIRUVHUYLFH
)
3OHDVHFRQWDFWTXDOLILHGSURIHVVLRQDOVIRUVHUYLFH
&
3OHDVHFRQWDFWTXDOLILHGSURIHVVLRQDOVIRUVHUYLFH
H6
,WFDQEHHOLPLQDWHGDIWHUUHVWDUWLQJWKHXQLW,IQRWSOHDVH
FRQWDFWTXDOLILHGSURIHVVLRQDOVIRUVHUYLFH
,WFDQEHHOLPLQDWHGDIWHUUHVWDUWLQJWKHXQLW,IQRW SOHDVH
(
1RWH,IWKHUH
UHRWKHUHUURUFRGHVSOHDVHFRQWDFWTXDOLILHGSURIHVVLRQDOVIRU
VHUYLFH
Warning
Ŷ:KHQEHORZSKHQRPHQRQRFFXUVSOHDVHWXUQRIIDLUFRQGLWLRQHUDQGGLVFRQ
IRUVHUYLFH
Ɣ3RZHUFRUGLVRYHUKHDWLQJRUGDPDJHG
Ɣ7KHUH¶VDEQRUPDOVRXQGGXULQJRSHUDWLRQ
Ɣ$LUVZLWFKWULSVRIIIUHTXHQWO\
Ɣ$LUFRQGLWLRQHUJLYHVRIIEXUQLQJVPHOO
Ɣ,QGRRUXQLWLVOHDNLQJ
Ŷ,IWKHDLUFRQGLWLRQHURSHUDWHVXQGHUDEQRUPDOFRQGLWLRQVLWPD\FDXVH
14
At least 6 in (15 cm)
Space to the ceiling
Installation dimension diagram
Space to the wall
At least 6 in (15 cm)
At least 6 in (15 cm)
Space to the wall
n
11
he
ot
et
c
pa
m)
0c
30
in(
At least 98 3/7 in (250cm)
st
lea
At
/9
81
ctio
tru
s
ob
S
15
Tools for installation
1 Level meter
2 Screw driver
3 Impact drill
4 Drill head
5 Pipe expander
6 Torque wrench
7 Open-end wrench
8 Pipe cutter
9 Leakage detector
10 Vacuum pump
11 Pressure meter
12 Universal meter
13 Inner hexagon spanner
Note:
14 Measuring tape
Ɣ3OHDVHFRQWDFWWKHORFDODJHQWIRULQVWDOODWLRQ
Selection of installation location
Basic requirement
Installing the unit in the following places maycause malfunction. If it is unavoidable, please consult the local
dealer:
1.The place with strong heat sources,
,
or volatile objects spread in the air.
2.The place with high-frequency
devices (such as welding machine,
medical equipment).
3.The place near coast area.
4.The place with oil or fumes in the air.
5.The place with sulfureted gas.
6.Other places with special circumstances.
7.The appliance shall not be installed in the laundry.
Indoor unit
1. There should be no obstruction near air
inlet and air outlet.
2. Select a location where the condensation water can be dispersed easily and
won't affect other people.
3. Select a location which is convenient to
connect the outdoor unit and near the
power socket.
4. Select a location which is out of reach
for children.
5. The location should be able to withstand
the weight of indoor unit and won't increase noise and vibration.
6. The appliance must be installed 2.5m
7. Don't install the indoor unit right above
the electric appliance.
8. Please try your best to keep way from
fluorescent lamp.
16
Requirements for electric connection
Safety precaution
1. Must follow the electric safety regulations when installing the unit.
air switch.
3. Make sure the power supply matches with the requirement of air conditioner.
Unstable power supply or incorrect wiring or malfunction. Please install proper
power supply cables before using the air conditioner.
4. Properly connect the live wire, neutral wire and grounding wire of power socket.
5. Be sure to cut off the power supply before proceeding any work related to
electricity and safety.
7. If the supply cord is damaged, it must be replaced by the manufacturer, its
8. The temperature of refrigerant circuit will be high, please keep the interconnection cable away from the copper tube.
9. The appliance shall be installed in accordance with national wiring regulations.
Grounding requirement
grounding with specialized grounding device by a professional. Please make
sure it is always grounded effectively, otherwise it may cause electric shock.
2. The yellow-green wire in air conditioner is grounding wire, which can't be used
for other purposes.
3. The grounding resistance should comply with national electric safety regulations.
4. The appliance must be positioned so that the plug is accessible.
5. An all-pole disconnection switch having a contact separation of at least 1/8 in (3mm)
in
6. Including an air switch with suitable capacity, please note the following table. Air
switch should be included magnet buckle and heating buckle function, it can
protect the circuit-short and overload. (Caution: please do not use the fuse only
for protect the circuit)
17
Installation of indoor unit
Step one: choosing installation location
rm it with the client.
Step two: install wall-mounting frame
1. Hang the wall-mounting frame on the wall; adjust it in horizontal position with the
plastic expansion particles in the holes.
3. Fix the wall-mounting frame on the wall with tapping screws (ST4.2X25TA) and
.
Step three: open piping hole
1. Choose the position of piping hole according to the direction of outlet pipe. The
position of piping hole should be a little lower than the wall-mounted frame,
shown as below.
、12K:
Wall
Level meter
Mark in the middle of it
Space
to the
wall
above
6 in (150 mm)
6 in (150 mm)
Right
Left
2 1/6 in (55mm)
2 1/6 in (55mm)
Rear piping hole
Rear piping hole
18K:
Wall
Wall
Space
to the
wall
above
24K:
Mark in the middle of it
Level meter
Wall
Wall
Mark in the middle of it
Level meter
Wall
Space
to the
wall
above
Space
to the
wall
above
Space
to the
wall
above
Space
to the
wall
above
6 in (150 mm)
6 in (150 mm)
6 in (150 mm)
6 in (150 mm)
Left
3/4 in (70mm)
Rear piping hole
Right
3/4 in (70mm)
Rear piping hole
Left
3/4 in (70mm)
Rear piping hole
Right
3/4 in (70mm)
Rear piping hole
2. Open a piping hole with the diameter o 2 1/6 in (55mm) 2 3/4 in (70mm)
position. In order to drain smoothly, slant the piping
hole on the wall slightly
18
Installation of indoor unit
Indoor
outdoor
Note:
Ɣ3D\DWWHQWLRQWRGXVWSUHYHQWLRQDQG
WDNHUHOHYDQWVDIHW\PHDVXUHVZKHQ
opening the hole.
Ɣ The plastic expansion particles are
QRWSURYLGHGDQGVKRXOGEHERXJKW
locally.
2 1/6 in (55mm)/
2 3/4 in (70mm)
5-10
Step four: outlet pipe
2. When select leading out the pipe
from left or right, please cut off the
corresponding hole on the bottom
case.
1. The pipe can be led out in the
direction of right, rear right, left or
rear left.
right
left
right
left
rear right
rear left
cut off
the hole
1. Aim the pipe joint at the corresponding
bellmouth.
pipe joint
union nut
pipe
2. Pretightening the union nut with hand.
3. Adjust the torque force by referring to the following sheet. Place the open-end
wrench on the pipe joint and place the torque wrench on the union nut. Tighten
the union nut with torque wrench.
19
Installation of indoor unit
Hex nut diameter
open-end
wrench
union nut
torque wrench
pipe
Tightening torque[ft.lb(N.m)]
1/4 in (6 mm)
20.34~27.12 ft.lb(15~20 N.m)
3/8 in (9.52 mm)
40.68~54.24 ft.lb(30~40 N.m)
1/2 in (12 mm)
54.24~74.58 ft.lb(40~55 N.m)
5/8 in (16 mm)
81.36~88.14 ft.lb(60~65 N.m)
3/4 in (19 mm)
94.93~101.7 ft.lb(70~75 N.m)
indoor pipe
4. Wrap the indoor pipe and joint of connection pipe with insulating pipe, and
then wrap it with tape.
insulating pipe
Note:
If a 18k indoor unit is to be connected with Free Match outdoor unit, a transitional
pipe joint (provided) should be added at the pipe joint of indoor unit evaporator
5/8 in (16 mm).
Please refer to step 1-4 during installation.
Step six: install drain hose
1. Connect the drain hose to the outlet pipe of
indoor unit.
drain hose
outlet pipe
drain hose
outlet
pipe
tape
Note:
Add insulating pipe in the indoor
drain hose in order to prevent
condensation.
The plastic expansion particles are
not provided.
drain hose
insulating pipe
Step seven: connect wire of indoor unit
panel
screw
1. Open the panel, remove the screw
on the wiring cover and then take
down the cover.
wiring cover
20
Installation of indoor unit
2. Make the power connection wire go
through the cable-cross hole at the back
of indoor unit and then pull it out from
the front side.
3. Remove the wire clip; connect the power
connection wire to the wiring terminal
according to the color; tighten the screw
cable-cross
hole
power connection
wire
with wire clip.
Wiring cover
Cable
Outdoor unit
4. Put wiring cover back and then tighten the screw.
5. Close the panel.
Note:
Ɣ All wires of indoor unit and outdoor unit should be connected by a professional.
for a new one. Avoid extending the wire by yourself.
installation.
Ɣ For the air conditioner without plug, an air switch must be installed in the line.
The air switch should be all-pole parting and the contact parting distance should
be more than 3mm
.
21
Installation of indoor unit
Step eight: bind up pipe
1. Bind up the connection pipe, power
cord and drain hose with the band.
indoor unit
connection pipe
drain hose
band
indoor and
outdoor power cord
gas
pipe
indoor power cord
liquid pipe
3. Bind them evenly.
4. The liquid pipe and gas pipe should
be bound separately at the end.
band
drain hose
2. Reserve a certain length of drain
hose and power cord for installation
when binding them. When binding to
a certain degree, separate the indoor
power and then separate the drain
hose.
Note:
Ɣ The power cord and control wire
can't be crossed or winding.
Ɣ The drain hose should be bound
at the bottom.
Step nine: hang the indoor unit
1. Put the bound pipes in the wall pipe and then make them pass through the wall
hole.
2. Hang the indoor unit on the wall-mounting frame.
3. Stuff the gap between pipes and wall hole with sealing gum.
4. Fix the wall pipe.
5. Check if the indoor unit is installed firmly and closed to the wall.
indoor
wall pipe
upper hook
outdoor
sealing gum
lower hook of
wall-mounting frame
Note:
Ɣ'RQRWEHQGWKHGUDLQKRVHWRRH[FHVVLYHO\LQRUGHUWRSUHYHQWEORFNLQJ
22
Check after installation
Items to be checked
Possible malfunction
The unit may drop, shake or emit noise.
Have you done the refrigerant leakage
test?
(heating) capacity.
It may cause condensation and water
dripping.
Is water drained well?
It may cause condensation and water
dripping.
Is the voltage of power supply according to the voltage marked on the
nameplate?
It may cause malfunction or damaging
the parts.
Is electric wiring and pipeline installed
correctly?
It may cause malfunction or damaging
the parts.
Is the unit grounded securely?
It may cause electric leakage.
Does the power cord follow the speci-
It may cause malfunction or damaging
the parts.
Is there any obstruction in the air inlet
and outlet?
(heating) capacity.
The dust and sundries caused during
installation are removed?
It may cause malfunction or damaging
the parts.
The gas valve and liquid valve of
connection pipe are open completely?
(heating) capacity.
Test operation
1. Preparation of test operation
Ɣ The client approves the air conditioner.
Ɣ6SHFLI\WKHLPSRUWDQWQRWHVIRUDLUFRQGLWLRQHUWRWKHFOLHQW
2. Method of test operation
Ɣ3XWWKURXJKWKHSRZHr, press ON/OFF button on the remote controller to start
operation.
Ɣ3UHVV02'(EXWWRQWRVHOHFW AUTO, COOL, DRY, F$1DQG+(AT to check
whether the operation is normal or not.
Ɣ,IWKHDPELHQWWHPSHUDWXUHLVORZHUWKDQć( 61 ℉), the air conditioner can’t
start cooling.
23
Configuration of connection pipe
1. Standard length of connection pipe
fference.
4. The additional refrigerant oil and refrigerant charging required after prolonging
connection pipe
of connection pipe.
The calculation ethod of additional refrigerant charging
of liquid pipe):
to the prolonged length of liquid pipe.
f
following sheet.
24
unt (on the
sis
Configuration of connection pipe
Additional refrigerant charging amount for R410A
Outdoor unit throttle
Liquid pipe(in/mm)
Gas pipe(in/mm) Cooling only(oz/ft (g/m)) Cooling and heating(oz/ft (g/m))
1/4 in (6 mm)
3/8 in (9.52 mm)
1/2 in (12 mm)
0.2 oz/ft (15 g/m)
0.2 oz/ft (20 g/m)
1/4 in (6 mm)
3/8 in (9.52 mm)
5/8 in (16 mm)
3/4 in (19 mm)
0.2 oz/ft (15 g/m)
0.5 oz/ft (50 g/m)
1/2 in (12 mm)
3/4 in (19 mm)
7/8 in (22.2 mm)
0.3 oz/ft (30 g/m)
1.3 oz/ft (120 g/m)
5/8 in (16 mm)
1 in (25.4 mm)
0.6 oz/ft (60 g/m)
1 1/4 in (31.8mm)
1.3 oz/ft (120 g/m)
3/4 in (19 mm)
_
2.7 oz/ft (250 g/m)
2.7 oz/ft (250 g/m)
7/8 in (22.2 mm)
_
3.8 oz/ft (350 g/m)
3.8 oz/ft (350 g/m)
25
Pipe expanding method
Note:
Improper pipe expanding is the main cause of refrigerant leakage. Please expand
the pipe according to the following steps:
A: Cut the pipe
E: Expand the port
r.
the distance of indoor unit and
outdoor unit.
hard
mold
expander
r.
pipe
pipe
pipe cutter
leaning
uneven
burr
Note:
fferent according to the
diameter, please refer to the sheet
below:
A
Outer diameter
B: Remove the burrs
Max
Min
1/20 in (1.3 mm) 0.02 in (0.7 mm)
prevent the burrs from getting into
the pipe.
3/50 in (1.6 mm) 1/24 in (1 mm)
pipe
0.07 in (1.8 mm) 1/24 in (1 mm)
shaper
1/10 in (2.4 mm) 2/25 in (2.2 mm)
downwards
F: Inspection
C: Put on suitable insulating pipe
D: Put on the union nut
connection pipe and outdoor valve;
install the union nut on the pipe.
port again according to the steps
above.
smooth surface
improper expanding
union pipe
leaning
pipe
l
26
damaged
surface
crack
uneven
thickness
66129917009
Edition Date: 11/14
Carrier Corporation
27
Catalog No: 40GJB-01OM
Was this manual useful for you? yes no
Thank you for your participation!