58002-1_ICON_Cooktops_Elec.qxd, page 1

58002-1_ICON_Cooktops_Elec.qxd, page 1
Electric Slide-In Cooktop
E36EC75HSS
36" min.
30" min. for
unprotected cabinet
24" min. for
protected surface
13"
max.
cabinet
depth
25 3/4"
35 7/8"
18"
min.
2"
7 3/4"
Optional 9" stainless
steel backsplash
1" min. recommended
distance between rear
edge of cutout and
nearest combustible
surface above countertop
7 1/2" min. to nearest
combustible wall
(either side of unit)
10"
Side inset 3/8"
7 1/2"
Approximate location
of junction box
3
/8"
7 1/4"
12"
35 3/16"
25" min.
22"
24"
1 1/8"
max.
* 35 3/16"
* 35 15/16"
* Both cutout dimensions are critical to proper cooktop
installation. Due to variations in countertop materials
it is recommended to undercut finished dimension
(35-15/16") and adjust upon installation of cooktop.
4" x 8" opening to
route armored cable
36" Electric Slide-In Cooktop Specifications
• Product
Weight – 68 Lbs.
phase 3- or 4-wire cable, 120 / 240 or 120 / 208 Volt, 60 Hertz AC
only electrical supply with ground required on separate circuit fused on
both sides of line.
• Connected Load (kW Rating) @ 240 / 208 Volts = 11.8 / 8.8 kW
• Amps @ 240 / 208 Volts = 49.2 / 42.6 Amps
• Always consult local and national electric codes.
• Respect critical dimensions as noted for proper installation of cooktop.
• Allow 2" space below armored cable opening to clear electrical cable and
allow space for installation of junction box on wall at back of cooktop.
• Overhead cabinetry should not exceed a 13" maximum depth.
• Allow 30" minimum clearance between top of cooktop and bottom of
unprotected wood or metal overhead cabinetry.
• Absolute minimum horizontal distance between overhead cabinets
installed to either side of appliance must be no less than maximum
width of appliance.
• Allow 24" minimum clearance when bottom of wood or metal overhead
cabinet is protected by not less than 1/8" flame-retardant millboard
covered with not less than No. 28 MGS sheet steel, 0.015" stainless
steel, 0.024" aluminum or 0.020" copper.
• Allow 1" minimum clearance between rear edge of cutout and nearest
combustible surface above countertop.
• Single
• Allow
7-1/2" minimum clearance from edge of cooktop to nearest
combustible wall on either side of unit.
• It is recommended that drawers not be used beneath cooktop.
• To reduce risk of fire when using overhead cabinetry, install vent hood
that projects horizontally a recommended minimum of 7" beyond bottom
of cabinets.
• Electric Slide-In Cooktop model E36EC75HSS is NOT approved to be
used over any Electrolux ICON® Single Wall Oven.
• Electric Slide-In Cooktop model E36EC75HSS (without optional
backsplash) is approved to be used in combination with an
Electrolux ICON® 36” Downdraft Vent. (Refer to Slide-In
Cooktop / Downdraft Vent Countertop Preparation page on web for
detailed installation specifications.)
Note: For planning purposes only. Refer to Product Installation Guide
on the web at electroluxicon.com for detailed instructions.
Optional Accessories
• When
replacing an existing cooktop with countertop cutout deeper
than 7-1/4" and less than 8-1/2", order free Depth Adjustment Filler
Kit – (PN # 903051-9010).
• 9" Stainless Steel Backsplash – (PN # 903048-9010).
• Black Knobs Kit – (PN # 903127-9010).
Electrolux Major Appliances, N.A.
USA • 10200 David Taylor Drive • Charlotte, NC 28262 • 1-877-4electrolux (1-877-435-3287) • electroluxicon.com
CANADA • 5855 Terry Fox Way • Mississauga, ON L5V 3E4 • 1-800-265-8352 • electroluxicon.ca
E36EC75HSS 10/10
© 2010 Electrolux Home Products, Inc.
High standards of quality at Electrolux Home Products, Inc. mean we are
constantly working to improve our products. We reserve the right to change
specifications or discontinue models without notice.
Printed in the U.S.A.
Slide-In Cooktop/Downdraft Vent
Countertop Preparation
Countertop Preparation for 30" & 36" Slide-In Cooktop / Downdraft Vent Installation
Downdraft vent cutout opening
in cooktop support platform
1
/4" min.
flat ledge
E
2 9/16"
D
C
B
A
1"countertop
overhang
E30DD75ESS/30" Cooktop Cutout Dimensions
30" Cooktop
E30GC74GPS*
For detailed cooktop and
downdraft vent installation
specifications, refer to
model-specific product
page and installation
guide on web
7 1/4"
7 1/2"
A
B
29 15/16" 29 3/16"
C
22"
Vertical noncombustible surface - rear wall
2513/16"
1
/4" min. flat ledge
Downdraft
chimney top
Countertop*
Studwall
D
E
25 13/16" 27 3/4"
3"
9
/32"
1 15/16"
Vent unit
Slide-In Cooktop
E36DD75ESS/36" Cooktop Cutout Dimensions
36" Cooktops
E36EC75DSS
E36EC75ESS
E36EC75HSS
E36GC75DSS*
E36GC75ESS*
E36GC75GSS*
E36GC76EPS*
E36GC76GPS*
A
35 15/16"
35 15/16"
35 15/16"
35 15/16"
35 15/16"
35 15/16"
35 15/16"
35 15/16"
B
35 3/16"
35 3/16"
35 3/16"
35 3/16"
35 3/16"
35 3/16"
35 3/16"
35 3/16"
C
22"
22"
22"
22"
22"
22"
22"
22"
D
25 13/16"
25 13/16"
25 13/16"
25 13/16"
25 13/16"
25 13/16"
25 13/16"
25 13/16"
E
33 3/4"
33 3/4"
33 3/4"
33 3/4"
33 3/4"
33 3/4"
33 3/4"
33 3/4"
Stiffener
*Proper combination installation will require cooktop power cord
to be relocated to underside of unit. (For details, refer to 30" & 36"
Gas Slide-In Cooktop Power Cord Relocation Instructions page.)
Slide-In Cooktop / Downdraft Vent
Countertop Preparation Specifications
End of cooktop
support platform
Back side of
cabinet front
Cooktop Installation Note:
To ensure proper installation, refer to model-specific installation
guide on web for cooktop dimensions, cutout dimensions and
cabinet requirements.
Countertop Preparation Note:
Countertop with backsplash may not allow enough flat area for
proper installation, 2-13/16" of flat countertop required behind
cooktop. No gap required between back of cooktop and front
of downdraft trim piece.
*Standard 25" countertop depth is NOT adequate for slide-in
cooktop / vent installations.
• Amps
• For
detailed Slide-In Cooktop installation, refer to model-specific product
page and installation guide on web. Plan installation so that all required
minimum clearances between cooktop, overhead cabinets and adjacent
vertical walls are provided.
• Position cooktop/vent cutout so all required minimum clearances are met.
• Minimum flat countertop area must meet or exceed combined overall
width and depth as shown. Standard 25" countertop depth is NOT
adequate for slide-in cooktop / vent installations.
• Separate circuits required for cooktop and vent. (Refer to product-specific
electrical specifications.)
• Always consult local and national electric and gas codes. Check local
building codes for installation requirements, as they may vary per locale.
• Proper combination installation will require 30" & 36" Gas Slide-In
Cooktop power cord to be relocated to underside of unit. (For details,
refer to 30" & 36" Gas Slide-In Cooktop Power Cord Relocation
Instructions on web.)
Downdraft Vent Specifications
• For
213/16"
detailed Downdraft Vent installations, refer to model-specific
product page and installation guide on web.
• Voltage Rating – 120V / 60 Hz / 15 Amps
• Connected Load (kW Rating) @ 120 Volts = 1.0 kW
(For use on adequately wired 120V, dedicated circuit having 2-wire
service with a separate ground wire. Appliance must be grounded for
safe operation.)
@ 120 Volts = 8.0 Amps
unit outside of building only.
• Vent must be installed in vertical orientation only.
• 1,600 CFM remote exhaust blower (PN # 5304444802) included with
vent – shipped in separate box.
• Do not use flexible duct. Round duct instead of rectangular duct
recommended, especially when elbows are required.
• When multiple elbows are necessary, ensure a minimum of 24" of straight
duct between any two elbows.
• Thermal breaks such as short section of nonmetallic duct, should be
used in areas of extreme cold.
• For most efficient airflow exhaust, use a straight run or as few elbows
as possible.
• Cold weather installations should have additional backdraft damper
installed.
• Installing a Downdraft Vent in combination with any gas cooking surface
will affect optimum burner efficiency.
• Downdraft Vents can NOT be used in combination with any cooktop
backsplash.
• Vent
Note: For planning purposes only. Refer to Product Installation Guide
on the web at electroluxicon.com for detailed instructions.
Electrolux Major Appliances, N.A.
USA • 10200 David Taylor Drive • Charlotte, NC 28262 • 1-877-4electrolux (1-877-435-3287) • electroluxicon.com
CANADA • 5855 Terry Fox Way • Mississauga, ON L5V 3E4 • 1-800-265-8352 • electroluxicon.ca
SIC_DDV_PREP 10/10
© 2010 Electrolux Home Products, Inc.
High standards of quality at Electrolux Home Products, Inc. mean we are
constantly working to improve our products. We reserve the right to change
specifications or discontinue models without notice.
Printed in the U.S.A.