TANKS FOR PROTEINS
W
LO
ST
CO
92000 MA•GEL•IN UNIVERSAL CAST-YOUR-OWN SYSTEM
The NEW Ma•GEL•In is truly a versatile protein
system designed to accomodate today’s
researcher. This system will allow you to cast
your own gels using the 10 cm x 10 cm glass
plates and easy-to-use casting system, or if you
prefer to use 8 cm x 10 cm precast gels, the
Ma•GEL•In will accommodate those as well.
This versatility comes from the specially
designed (patent pending) gel capture system
that allows plates in a 10 cm x 10 cm format or
cast-your-own glass plates in a 10 cm x 10 cm
format.
Casting your oun gels: The #920000 comes with
three sets of glass plates and a 2-place casting
system for casting your own gels. The 2-place
casting system #921000 has a very small
footprint (10 cm x 15 cm), utilizing minimal
space on the counter. The glass plates are held
together using neoprene spacers.
40
Once assembled, the glass sandwich is placed in
the casting system, and the lid is mounted to the
top pf the casting system. The gel can now be
cast through the opening in the lid. Once the gel
has polymerezed, the glass sandwiches can be
removed from the casting system, placed in the
gel capture unit, and set into the buffer tank.
Quick and simple!
Pre-Cast gels: Using the same gel capture unit,
8 cm x 10 cm precast polyacrylamide gels can be
inserted, locked in place, and set into he buffer
tank. The Ma•GEL•In will accommodate various
brands of pre-cast gel. The #920000 is an allinclusive, easy-to-use, protein electrophoresis
system designed for years of continuous use.
“Discover what Ma•GEL•In can do for you!”
The tank holds a minimum of 350 ml of buffer.
For longer runs, the tank can be filled to a
maximm of 850 ml. A stir bar can be placed in
the tank to recirculate the buffer to keep the
ionic concentration constant.
The tank includes a patented vented lid to further
reduce heat buildup during the gel run.
Apelex cata 2009-5 anglais:Mise en page 1
18/01/10
9:40
Page 41
TANKS FOR PROTEINS
1
2
3
4
5
6
7
8
9
10
11
SET UP
1 • Create glass plate sandwich with spacers and glass slides.
2 • Place glass sandwich into casting system-notched plates
ORDERING INFORMATION
92000
to inside.
3 • secure lid by pressing down and inserting locking knobs.
4 • Add gel through opening in lid.
Description
5 • Carefully remove combs.
6 • Insert gel plates in gel capture device per instructions.
7 • Turn cams inward to secure gel plates.
8 • Place gel capture device in tank-note keyed inserts.
9 • Pour appropriate amount of buffer.
92030
92031
92032
92033
PS 304
TECHNICAL SPECIFICATIONS - CONSTRUCTION
• Inner gel support
• Clamp assemblies
• Buffer chamber
• Gaskets
• Shipping weight
• Overall size
• Gel size
Molded ABS
Molded polycarbonate
3/8” acrylic
Extruded silicone
2.2 Kg
17 cm (L) x 17 cm (W) x 18 cm (H)
8 cm (L) x 10 cm (W)
or 10 cm (L) x 10 cm (W)
The 92000 comes with a patented vented lid.
Patent #5779,869.
Well Wildth
0.8 mm x 10 tooth
0.8 mm x 12 tooth
0.8 mm x 15 tooth
0.8 mm x 1 sample
5.86 mm
4.22 mm
3.38 mm
70 mm
Sample Volume
Per mm Gel
28.13 µl
20.26 µl
16.22 µl
336 µl
SUGGESTED POWER SUPPLY
10 • Load the samples in the wells.
11 • Initiate desired program.
Ma•GEL•In Universal Protein Cast-Your-Own System.
Includes: center support, buffer tank, vented lid,
casting system, three inner and three outer glass plates,
two sets of 0.8 mm side spacers,
two 0.8 mm x 15 tooth combs, power cords, and manual.
300 Volts
400 mA
Cat. No. 160500
ORDERING INFORMATION
50500
92010
92020
92025
92040
92050
92060
92070
92071
92072
92100
92200
92500
Description
Replacement Power Cords
Inner Glass Plate, Set of 5 (Notched)
Outer Glass Plate, Set of 5
0.8 Spacer Set (2 Spacers)
Replacement Tank
Replacement Gel Capture Device
Replacement Lid
Replacement Gaskets, casting System, 2 Each
Replacement Thumb Screws, 2 Each
Replacement Tank Connector Kit
Protein Casting System, 2 Place
Protein Casting System, 8 Place
Western Transfer Module
41
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement