EN CN2 CN1 TECHNICAL MANUAL 1 2 3 4 5 6 7 8 JP1 DL1 DL2 DL3 V+ VA B V+ VA B JP2 V+ AUX1 VV+ AUX2 V24H 01 02 03 04 13.8 VDC / 5A power supply unit in metal box Art. VEDOPSU5A Warning • Install the equipment by carefully following the instructions given by the manufacturer and in compliance with the standards in force. • All the equipment must only be used for the purpose it was designed for. Comelit Group S.p.A. declines any responsibility for improper use of the apparatus, for any alterations made by others for any reason or for the use of non-original accessories or materials. • Installation, assembly and servicing operations of electrical devices must only be performed by specialised electricians. • For standard-compliant installation, a suitable (two-pole) device must be provided for isolating and protecting the network power supply in the building's electrical system (see diagram), in compliance with the standards in force (law 46/90): for example, a two-pole overload circuit breaker with rated current 6A. There must be a gap of at least 3 [mm] between the isolating device contacts. EARTH NEUTRAL PHASE control panel 230 V 50 Hz • Carry out the maintenance and operation test of all the components (smoke sensors, movement sensors, ...) as indicated in the respective technical manuals. • Replace the protections on the terminals. Product labels • All articles have an ID label for product traceability. Two examples are shown below: article code EAN article identification code 000P1515XXXXXXXX Via Don Arrigoni, 5 24020 Rovetta (BG) - Italy article code VEDOPSU5A 000P1515XXXXXXXX Via Don Arrigoni, 5 - 24020 Rovetta (BG) - Italy interpretation serial number: protocol number serial number manufacturer's name serial number 000PWWYYXXXXXXXX date of manufacture week of manufacture (WW) and year of manufacture (YY) (in the sample label 1515= week15 of the year 15) Identification label Certifications Grade 2 / Class II • All the products comply with the requirements of the 2014/30/EU and 2014/35/EU directives. This is proved by the CE mark on the products themselves. EN 50131-1 EN 50131-6 EN 60950 • All the system components must have safety grade 2 or higher to obtain grade 2 alarm system certification according to standard EN50131. manufacturer's name VEDOPSU5A Vin:230V~ +10% -15% 50/60Hz Max Current 1.3A VEDOPSU5A article code Manutenzione • Disconnect the power supply before carrying out any maintenance procedures. • It is recommended to check the correct operation of the safety system periodically (at least once a month). Remove any dust accumulated in the control panel housing with a damp cloth, without using any solvent, and check that there are no foreign bodies. • Check the conditions of the connectors and the conductors. Table of contents Warning............................................................................................. 2 Description........................................................................................ 3 Identification of parts and separation of circuits.......................... 3 Main features.................................................................................... 4 Addressing.................................................................................................5 Setting the speed of the card on the bus...............................................5 Terminal block......................................................................................4 Technical characteristics ................................................................ 6 Installation......................................................................................... 7 Power supply unit management card (PCBPSU)...................................4 Opening The Housing Art. Art. BOXMETAL............................................7 Terminal block M1-M2-M3-M4-M5-M6...............................................4 Fixing the housing Art. BOXMETAL to the wall......................................7 LED signals..........................................................................................5 Installation of Art. PCBPSU......................................................................8 Power supply unit connector...............................................................5 Installation of Art. PSU50.........................................................................8 Jumpers di configurazione...................................................................5 Installation of Art. 30076003 / 30076004.................................................8 Switching power supply unit Art. PSU50................................................4 Anti-tamper connection.......................................................................5 Connecting V- reference terminal........................................................5 2 Earth connection..................................................................................5 Programming Art. PCBPSU............................................................. 5 Description This device can be used to expand Vedo series systems by providing: • A new branch to the RS485 data BUS, electrically isolated with the corresponding power supply output. • 2 auxiliary power supply outputs. • 4 Open Collector indication outputs. • One terminal for tamper contact. Identification of parts and separation of circuits 2 3 CN2 CN1 1 4 1 2 3 4 5 6 7 8 DL1 DL2 DL3 V+ VA B V+ VA B JP2 NO JP1 V+ AUX1 VV+ AUX2 V24H 01 02 03 04 CO A 5 C A C 1 2 A D B B 4 3 D B C CO NO D 4 7 6 1.Battery connector 6. Internal fuse 250V~ T2.5A (for PSU50) 2.PSU connector 7.High Voltage Cables. 3.Balance resistor A. Power supply unit management card (PCBPSU) 4.Tamper connectors B. Power supply unit PSU50 5.Earth connection according to standard EN60950. C. Battery Art. 30076003 / Art. 30076004. 3 Main features CN2 1 2 3 4 5 CN1 L M1 V+ VA B V+ VA B 6 M2 M3 7 DL1 DL2 DL3 JP2 JP1 V+ AUX1 VV+ AUX2 V24H 01 02 03 04 N 1 2 3 4 5 6 7 8 8 M4 1.GND 6.Data BUS in 2. V+ 7.Data BUS out 3.Connection terminals 8.Outputs Power Supply 4.Balance resistor 9.Outputs 5.Screws for earth connection 10.CN2 Battery connector 9 M5 10 11 M6 11.CN1 PSU connector Holes for fixing the PCBPSU card to the metal housing. Switching power supply unit Art. PSU50 Open Frame switching power supply unit, PB battery charger, 90-260 Vac 50/60 Hz input, 13.8 Vdc / 5 A output. Safety grade: EN50131 grade 2. Terminal block Earth connection terminal (not used) Terminal block M1-M2-M3-M4-M5-M6 Earth connection terminal BUS IN V+485 communication BUS power supply input positive V- 485 communication BUS power supply input negative A RS485 data BUS for connection to the control panel (IN) - A B RS485 data BUS for connection to the control panel (IN)-B N Neutral L Phase V+Power supply positive output. 485 communication bus. Limited to 1.5A Power supply unit management card (PCBPSU) • The auxiliary power supplies provided by the card are acquired by the mains power supply units connected to connector CN1. • The Open Collector outputs are configured to provide fault and anomaly indications. • If the power supply unit is not connected to a control panel, the indication delay times are as follows: power supply network alarm delay=1 minute, battery alarm delay=5 minutes. • When the device is connected to a Vedo series control panel, it is possible to monitor the status of the auxiliary power supplies and the power supply unit itself. In this case network alarm delay and battery alarm delay times can be configured (using the Safekey keypad or the Safe Manager software). 4 BUS OUT V- Power supply negative - output reference. 485 communication BUS power supply A RS485 data BUS for connection to other devices (OUT) A B RS485 data BUS for connection to other devices (OUT) B Outputs Power Supply V+AUX1Auxiliary 1 power supply output positive. Limited to 1.5A V- Auxiliary 1 power supply output negative V+AUX2 Auxiliary 2 power supply output positive. Limited to 1.5A V- Auxiliary 2 power supply output negative 24H Tamper contact input Outputs O1Open Collector Output O1. Programmed as module AntiSabotage by default. The output is active when module sabotage occurs. O2Open Collector Output O2. Programmed as module Low Battery Anomaly by default. The output is active when the programmed time has elapsed since the moment at which the battery was no longer detected or the does not respect the values indicated in the technical specifications. Anti-tamper connection The 24H terminal needs the Tamper contact to be connected in single balanced configuration. A resistance of 1.8KΩ, in series with the contact, is required. O3Open Collector Output O3. Programmed as module No 230V Mains Anomaly by default. The output is active when the programmed time has elapsed since the moment at which the network was no longer detected. O4Open Collector Output O4. Programmed by default to indicate the fault of the power supply unit or of the power supply outputs. The output is active when there is a fault in the power supply unit or on the power supply outputs V+bus, VAUX1 or VAUX2 LED signals DL1 Flashing slowly: no data transfer over bus at the speed set using the dip switch. Flashing quickly: data transfer over bus in progress. DL2 Off: the peripheral is communicating correctly. Connecting V- reference terminal The incoming RS485 bus (bus IN) is electrically isolated from the rest of the card. As a result, the V- input terminal must only be connected to the bus running towards the control panel. Do not connect the V- terminal for the incoming bus to other V- terminals present, and do not use it as a reference for outgoing power supply voltage values. This could damage the devices used, or cause them to malfunction. Earth connection Very slow flashing: (approx. 3 seconds) no data package on the BUS. DL3 On: indicates that one of the Open Collector outputs is under protection due to a short circuit. Power supply unit connector CN1 External 230 V - 50 Hz power supply unit connector CN2 Battery connector For standard-compliant installation, connect the earth terminal to the system earth, passing through the power supply earth connection using the yellow/green cable supplied with the device housings. To guarantee system certification, the power supply unit must be positioned in boxes protected by an anti-opening switch, or in the control panel housing. The 24h input must be connected to a balanced line, and connected to a Vedo system input line. Jumpers di configurazione JP1 RS485 output termination* JP2 RS485 input termination* * Always remember to insert an end-of-line resistor between A and B of the 485 connection (using the relevant jumpers) to the two ends of the main bus line. Programming Art. PCBPSU Addressing Setting the speed of the card on the bus The device address must be unique and can only be programmed using dip switches. Note that the standard speed of the bus for VEDO control panels is 38400 Baud. N° 1 2 3 4 5 6 7 8 DIP1 OFF ON OFF ON OFF ON OFF ON DIP2 OFF OFF ON ON OFF OFF ON ON DIP3 OFF OFF OFF OFF ON ON ON ON DIP4 DIP5 Not used DIP6 BAUD 9600 38400 (default) 57600 115200 DIP7 OFF ON OFF ON DIP8 OFF OFF ON ON 5 Technical characteristics Art. PSU50 complies with standards EN50130-4:2011, EN 60950-1:2006 + A11:2009 + A1:2010 + A12:2011 + A2:2013. Art. BOXMETAL complies with standards EN50131-1, EN50131-3, EN50131-6, EN50136-1, EN50136-2, EN 60950-1:2006 + A11:2009 + A1:2010 + A12:2011, EN50130-4) PSU50 Name of manufacturer / supplier Dimensions (L x H x D) Weight Input voltage AC input frequency AC Alternating Current Output voltage Rated current Output voltage ripple Voltage surge protection Overload protection Comelit Group S.p.A. 113 x174 x57 mm 435 g 230V~ + 10% -15% 50/60 Hz @230V~ : 1,3A 14,0 V ± 2% 5A Max 300mV +50% 110~180% rated output power -10° / + 55° with warm dry air Operating temperature and Operating humidity -10° / + 40° C with max + 93% RH (not condensed) Safety grade 2 according to EN50131-1* Environmental class II according to EN50131-1 PCBPSU Name of manufacturer / supplier Dimensions (L x H x D) Weight Housings supported Comelit Group S.p.A. 140x127x23mm 115gr Art. BOXMETAL PSU15 Power supply units supported PSU50 Art. 30076003 12V/7Ah Batteries supported Art. 30076004 12V and 18Ah Max. battery charging current 0,8A Battery 80% charging time 8h/19h Low Battery Fault Generation in presence of EPS 12V Low Battery Fault Generation in absence of EPS 11,5V Switch-off Art. PCBPSU in absence of EPS for Protection against Deep Discharges 10,5V Intervention voltage of the protection against voltage surges: battery disconnection 15V Maximum current for Outputs V+BUS OUT,V+AUX1, V+AUX2 1,5A Output voltage operating range (V+BUS OUT,V+AUX1,V+AUX2) 10÷15V CN1 input voltage operating range 12,8÷15V CN2 input voltage operating range (Battery) 10,5÷15V Control panel card consumption Art. PCBPSU (min./max.) 15/20mA Maximum current available for external devices Grade 2: 1,45A Maximum current delivered to outputs TC1 and TC2 100mA -10° / + 55° with warm dry air Operating temperature and Operating humidity -10° / + 40° C with max + 93% RH (not condensed) Type of power supply unit TIPO A according to standard EN50131-6 Environmental class II according to EN50131-1 BOXMETAL Name of manufacturer / supplier Comelit Group S.p.A. Dimensions (L x H x D) 315 x 440 x 95 mm Weight 3250 g (housing + fixing supports) -10° / + 55° with warm dry air Operating temperature and Operating humidity -10° / + 40° C with max + 93% RH (not condensed) Certified safety grade 2 according to EN50131-1* Environmental class II according to EN50131-1 * Respecting any indications for configuration and installation 6 Installation Opening The Housing Art. Art. BOXMETAL 2 2 open 1 2 1 Fixing the housing Art. BOXMETAL to the wall When fixing the product to the wall, use the 5 wall plugs supplied: FISCHER SX 6 S ART.570021. A standard-compliant connection to the electric power network must be provided. For standard-compliant installation, prepare the cables and leads necessary for wiring the system as indicated on page 3 In order to guarantee Grade 2 certification according to EN50131-1 the tamper must be mounted and configured correctly. 2 1 5mm 1 2 2 1 3 4 7 Installation of Art. PCBPSU Installation of Art. PSU50 CLACK! 1 2 1 2 3 Installation of Art. 30076003 / 30076004 In order to guarantee certification of the system it is necessary to fix the 7Ah or 18Ah battery to the metal housing with the double-sided tape provided. # only with Art. 30076004 1 2 w w w.comelitgroup.com Via Don Arrigoni, 5 - 24020 Rovetta (BG) - Italy 1ª edizione 11/2016 cod. 2G40001479
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
advertisement