13.8 VDC / 5A power supply unit in metal box Art

13.8 VDC / 5A power supply unit in metal box Art
EN
CN2
CN1
TECHNICAL
MANUAL
1 2 3 4 5 6 7 8
JP1
DL1
DL2
DL3
V+
VA
B
V+
VA
B
JP2
V+ AUX1
VV+ AUX2
V24H
01
02
03
04
13.8 VDC / 5A power supply unit in metal box
Art. VEDOPSU5A
Warning
• Install the equipment by carefully following the
instructions given by the manufacturer and in
compliance with the standards in force.
• All the equipment must only be used for the purpose
it was designed for. Comelit Group S.p.A. declines
any responsibility for improper use of the apparatus,
for any alterations made by others for any reason or
for the use of non-original accessories or materials.
• Installation, assembly and servicing operations
of electrical devices must only be performed by
specialised electricians.
• For standard-compliant installation, a suitable
(two-pole) device must be provided for isolating
and protecting the network power supply in the
building's electrical system (see diagram), in
compliance with the standards in force (law 46/90):
for example, a two-pole overload circuit breaker
with rated current 6A. There must be a gap of at
least 3 [mm] between the isolating device contacts.
EARTH
NEUTRAL
PHASE
control
panel
230 V
50 Hz
• Carry out the maintenance and operation test of
all the components (smoke sensors, movement
sensors, ...) as indicated in the respective technical
manuals.
• Replace the protections on the terminals.
Product labels
• All articles have an ID label for product traceability.
Two examples are shown below:
article code
EAN article
identification code
000P1515XXXXXXXX
Via Don Arrigoni, 5
24020 Rovetta (BG) - Italy
article code
VEDOPSU5A
000P1515XXXXXXXX
Via Don Arrigoni, 5 - 24020 Rovetta (BG) - Italy
interpretation serial number:
protocol number
serial number
manufacturer's name
serial number
000PWWYYXXXXXXXX
date of manufacture
week of manufacture (WW)
and year of manufacture (YY)
(in the sample label
1515= week15 of the year 15)
Identification label
Certifications
Grade 2 / Class II
• All the products comply with the requirements of
the 2014/30/EU and 2014/35/EU directives. This is
proved by the CE mark on the products themselves.
EN 50131-1
EN 50131-6
EN 60950
• All the system components must have safety grade 2
or higher to obtain grade 2 alarm system certification
according to standard EN50131.
manufacturer's name
VEDOPSU5A
Vin:230V~ +10% -15% 50/60Hz
Max Current
1.3A
VEDOPSU5A
article code
Manutenzione
• Disconnect the power supply before carrying out any
maintenance procedures.
• It is recommended to check the correct operation
of the safety system periodically (at least once a
month). Remove any dust accumulated in the control
panel housing with a damp cloth, without using any
solvent, and check that there are no foreign bodies.
• Check the conditions of the connectors and the
conductors.
Table of contents
Warning............................................................................................. 2
Description........................................................................................ 3
Identification of parts and separation of circuits.......................... 3
Main features.................................................................................... 4
Addressing.................................................................................................5
Setting the speed of the card on the bus...............................................5
Terminal block......................................................................................4
Technical characteristics ................................................................ 6
Installation......................................................................................... 7
Power supply unit management card (PCBPSU)...................................4
Opening The Housing Art. Art. BOXMETAL............................................7
Terminal block M1-M2-M3-M4-M5-M6...............................................4
Fixing the housing Art. BOXMETAL to the wall......................................7
LED signals..........................................................................................5
Installation of Art. PCBPSU......................................................................8
Power supply unit connector...............................................................5
Installation of Art. PSU50.........................................................................8
Jumpers di configurazione...................................................................5
Installation of Art. 30076003 / 30076004.................................................8
Switching power supply unit Art. PSU50................................................4
Anti-tamper connection.......................................................................5
Connecting V- reference terminal........................................................5
2
Earth connection..................................................................................5
Programming Art. PCBPSU............................................................. 5
Description
This device can be used to expand Vedo series systems by providing:
• A new branch to the RS485 data BUS, electrically isolated with the corresponding power supply output.
• 2 auxiliary power supply outputs.
• 4 Open Collector indication outputs.
• One terminal for tamper contact.
Identification of parts and separation of circuits
2
3
CN2
CN1
1
4
1 2 3 4 5 6 7 8
DL1
DL2
DL3
V+
VA
B
V+
VA
B
JP2
NO
JP1
V+ AUX1
VV+ AUX2
V24H
01
02
03
04
CO
A
5
C
A
C
1
2
A
D
B
B
4
3
D
B
C
CO
NO
D
4
7
6
 1.Battery connector
  6. Internal fuse 250V~ T2.5A (for PSU50)
 2.PSU connector
 7.High Voltage Cables.
 3.Balance resistor
A. Power supply unit management card (PCBPSU)
 4.Tamper connectors
B. Power supply unit PSU50
 5.Earth connection according to standard EN60950.
C. Battery Art. 30076003 / Art. 30076004.
3
Main features
CN2
1
2
3
4 5
CN1
L
M1
V+
VA
B
V+
VA
B
6
M2
M3
7
DL1
DL2
DL3
JP2
JP1
V+ AUX1
VV+ AUX2
V24H
01
02
03
04
N
1 2 3 4 5 6 7 8
8
M4
 1.GND
 6.Data BUS in
 2. V+
 7.Data BUS out
 3.Connection terminals
 8.Outputs Power Supply
 4.Balance resistor
 9.Outputs
 5.Screws for earth connection
10.CN2 Battery connector
9
M5
10
11
M6
11.CN1 PSU connector
Holes for fixing the PCBPSU card to the metal housing.
Switching power supply unit Art. PSU50
Open Frame switching power supply unit, PB battery charger,
90-260 Vac 50/60 Hz input, 13.8 Vdc / 5 A output.
Safety grade: EN50131 grade 2.
Terminal block
Earth connection terminal (not used)
Terminal block M1-M2-M3-M4-M5-M6
Earth connection terminal
BUS IN
V+485 communication BUS power supply input positive
V- 485 communication BUS power supply input negative
A RS485 data BUS for connection to the control panel (IN) - A
B RS485 data BUS for connection to the control panel (IN)-B
N Neutral
L Phase
V+Power supply positive output. 485 communication bus.
Limited to 1.5A
Power supply unit management card
(PCBPSU)
• The auxiliary power supplies provided by the card are
acquired by the mains power supply units connected to
connector CN1.
• The Open Collector outputs are configured to provide
fault and anomaly indications.
• If the power supply unit is not connected to a control
panel, the indication delay times are as follows: power
supply network alarm delay=1 minute, battery alarm
delay=5 minutes.
• When the device is connected to a Vedo series control
panel, it is possible to monitor the status of the auxiliary
power supplies and the power supply unit itself. In this
case network alarm delay and battery alarm delay times
can be configured (using the Safekey keypad or the Safe
Manager software).
4
BUS OUT
V- Power supply negative - output reference. 485
communication BUS power supply
A RS485 data BUS for connection to other devices (OUT) A
B RS485 data BUS for connection to other devices (OUT) B
Outputs Power Supply
V+AUX1Auxiliary 1 power supply output positive. Limited to
1.5A
V- Auxiliary 1 power supply output negative
V+AUX2 Auxiliary 2 power supply output positive. Limited to
1.5A
V- Auxiliary 2 power supply output negative
24H Tamper contact input
Outputs
O1Open Collector Output O1. Programmed as module AntiSabotage by default. The output is active when module
sabotage occurs.
O2Open Collector Output O2. Programmed as module Low
Battery Anomaly by default. The output is active when
the programmed time has elapsed since the moment
at which the battery was no longer detected or the
does not respect the values indicated in the technical
specifications.
Anti-tamper connection
The 24H terminal needs the Tamper contact to be connected
in single balanced configuration.
A resistance of 1.8KΩ, in series with the contact, is required.
O3Open Collector Output O3. Programmed as module No
230V Mains Anomaly by default. The output is active
when the programmed time has elapsed since the
moment at which the network was no longer detected.
O4Open Collector Output O4. Programmed by default to
indicate the fault of the power supply unit or of the power
supply outputs. The output is active when there is a fault
in the power supply unit or on the power supply outputs
V+bus, VAUX1 or VAUX2
LED signals
DL1
Flashing slowly: no data transfer over bus at the speed
set using the dip switch.
Flashing quickly: data transfer over bus in progress.
DL2
Off: the peripheral is communicating correctly.
Connecting V- reference terminal
The incoming RS485 bus (bus IN) is electrically isolated from
the rest of the card. As a result, the V- input terminal must
only be connected to the bus running towards the control
panel.
Do not connect the V- terminal for the
incoming bus to other V- terminals present,
and do not use it as a reference for outgoing
power supply voltage values. This could
damage the devices used, or cause them to
malfunction.
Earth connection
Very slow flashing: (approx. 3 seconds) no data package
on the BUS.
DL3
On: indicates that one of the Open Collector outputs is
under protection due to a short circuit.
Power supply unit connector
CN1
External 230 V - 50 Hz power supply unit connector
CN2
Battery connector
For standard-compliant installation, connect
the earth terminal to the system earth, passing
through the power supply earth connection
using the yellow/green cable supplied with the
device housings.
To guarantee system certification, the power
supply unit must be positioned in boxes
protected by an anti-opening switch, or in the
control panel housing. The 24h input must be
connected to a balanced line, and connected to
a Vedo system input line.
Jumpers di configurazione
JP1
RS485 output termination*
JP2
RS485 input termination*
* Always remember to insert an end-of-line resistor
between A and B of the 485 connection (using the
relevant jumpers) to the two ends of the main bus line.
Programming Art. PCBPSU
Addressing
Setting the speed of the card on the bus
The device address must be unique and can only be
programmed using dip switches.
Note that the standard speed of the bus for VEDO control
panels is 38400 Baud.
N°
1
2
3
4
5
6
7
8
DIP1
OFF
ON
OFF
ON
OFF
ON
OFF
ON
DIP2
OFF
OFF
ON
ON
OFF
OFF
ON
ON
DIP3
OFF
OFF
OFF
OFF
ON
ON
ON
ON
DIP4
DIP5
Not used
DIP6
BAUD
9600
38400 (default)
57600
115200
DIP7
OFF
ON
OFF
ON
DIP8
OFF
OFF
ON
ON
5
Technical characteristics
Art. PSU50 complies with standards EN50130-4:2011, EN 60950-1:2006 + A11:2009 + A1:2010 + A12:2011 +
A2:2013. Art. BOXMETAL complies with standards EN50131-1, EN50131-3, EN50131-6, EN50136-1, EN50136-2,
EN 60950-1:2006 + A11:2009 + A1:2010 + A12:2011, EN50130-4)
PSU50
Name of manufacturer / supplier
Dimensions (L x H x D)
Weight
Input voltage
AC input frequency
AC Alternating Current
Output voltage
Rated current
Output voltage ripple
Voltage surge protection
Overload protection
Comelit Group S.p.A.
113 x174 x57 mm
435 g
230V~ + 10% -15%
50/60 Hz
@230V~ : 1,3A
14,0 V
± 2%
5A Max
300mV
+50%
110~180% rated output power
-10° / + 55° with warm dry air
Operating temperature and Operating humidity -10° / + 40° C with max + 93% RH (not
condensed)
Safety grade 2 according to EN50131-1*
Environmental class II according to EN50131-1
PCBPSU
Name of manufacturer / supplier
Dimensions (L x H x D)
Weight
Housings supported
Comelit Group S.p.A.
140x127x23mm
115gr
Art. BOXMETAL
PSU15
Power supply units supported
PSU50
Art. 30076003 12V/7Ah
Batteries supported
Art. 30076004 12V and 18Ah
Max. battery charging current 0,8A
Battery 80% charging time 8h/19h
Low Battery Fault Generation in presence of EPS 12V
Low Battery Fault Generation in absence of EPS 11,5V
Switch-off Art. PCBPSU in absence of EPS for Protection against Deep Discharges 10,5V
Intervention voltage of the protection against voltage surges: battery disconnection 15V
Maximum current for Outputs V+BUS OUT,V+AUX1, V+AUX2 1,5A
Output voltage operating range (V+BUS OUT,V+AUX1,V+AUX2) 10÷15V
CN1 input voltage operating range 12,8÷15V
CN2 input voltage operating range (Battery) 10,5÷15V
Control panel card consumption Art. PCBPSU (min./max.) 15/20mA
Maximum current available for external devices Grade 2: 1,45A
Maximum current delivered to outputs TC1 and TC2 100mA
-10° / + 55° with warm dry air
Operating temperature and Operating humidity -10° / + 40° C with max + 93% RH (not
condensed)
Type of power supply unit TIPO A according to standard EN50131-6
Environmental class II according to EN50131-1
BOXMETAL
Name of manufacturer / supplier Comelit Group S.p.A.
Dimensions (L x H x D) 315 x 440 x 95 mm
Weight 3250 g (housing + fixing supports)
-10° / + 55° with warm dry air
Operating temperature and Operating humidity -10° / + 40° C with max + 93% RH (not
condensed)
Certified safety grade 2 according to EN50131-1*
Environmental class II according to EN50131-1
* Respecting any indications for configuration and installation
6
Installation
Opening The Housing Art. Art. BOXMETAL
2
2
open
1
2
1
Fixing the housing Art. BOXMETAL to the wall
When fixing the product to the wall, use the 5 wall plugs supplied: FISCHER SX 6 S ART.570021.
A standard-compliant connection to the electric power network must be provided.
For standard-compliant installation, prepare the cables and leads necessary for wiring the system as
indicated on page 3
In order to guarantee Grade 2 certification according to EN50131-1 the tamper must be mounted and
configured correctly.
2
1
5mm
1
2
2
1
3
4
7
Installation of Art. PCBPSU
Installation of Art. PSU50
CLACK!
1
2
1
2
3
Installation of Art. 30076003 / 30076004
In order to guarantee certification of the system it is necessary to fix the 7Ah or 18Ah battery to the metal
housing with the double-sided tape provided.
# only with Art. 30076004
1
2
w w w.comelitgroup.com
Via Don Arrigoni, 5 - 24020 Rovetta (BG) - Italy
1ª edizione 11/2016
cod. 2G40001479
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement