BFT DEIMOS BT H QSC Installation and User Manual
Advertisement
Advertisement
8
0 2 7 9 0 8 3 9 1 0 8 7
ATTUATORE PER CANCELLI SCORREVOLI A CREMAGLIERA
ACTUATOR FOR RACK SLIDING GATES
ACTIONNEUR POUR PORTAILS COULISSANTS A CREMAILLERE
ANTRIEB FÜR ZAHNSTANGEN-SCHIEBETORE
SERVOMOTOR PARA CANCELAS CORREDERAS DE CREMALLERA
ACTUATOR VOOR SCHUIFHEKKEN MET TANDHEUGEL
ISTRUZIONI D’USO E DI INSTALLAZIONE INSTALLATION AND USER’S MANUAL INSTRUCTIONS D’UTILISATION ET D’INSTALLATION INSTALLATIONS-UND GEBRAUCHSANLEITUNG INSTRUCCIONES DE USO Y DE INSTALACION INST
Attenzione! Leggere attentamente le “Avvertenze” all’interno! Caution! Read “Warnings” inside carefully! Attention! Veuillez lire attentivement les Avertissements qui se trouvent à l’intérieur!
Achtung! Bitte lesen Sie aufmerksam die „Hinweise“ im Inneren! ¡Atención¡ Leer atentamente las “Advertencias” en el interior! Let op! Lees de “Waarschuwingen” aan de binnenkant zorgvuldig!
INSTALLAZIONE VELOCE-QUICK INSTALLATION-INSTALLATION RAPIDE
SCHNELLINSTALLATION-INSTALACIÓN RÁPIDA - SNELLE INSTALLATIE
A
> 25mm
B
3x1mm 2
5x0,75mm
2
3x1.5mm
2
2x0.75mm
2
3x1.5mm
2
2x1.5mm
2
RG58
3x1.5mm
2
PREDISPOSIZIONE TUBI, TUBE ARRANGEMENT,
PRÉDISPOSITION DES TUYAUX, VORBEREITUNG DER LEITUNGEN,
DISPOSICIÓN DE TUBOS, VOORBEREIDING LEIDINGEN.
3x1.5mm
2
C
> 10mm
“X”
= Cremagliera, Rack,
Crémaillère, Zahnstange,
Cremallera, Tandheugel
25mm + “X”
Predisposizione fissaggio motore, Preparation for motor mounting,
Aménagement fixation moteur, Vorbereitung Motorbefestigung,
Disposición fijación del motor, Voorbereiding bevestiging motor.
D
Y
D1
Montaggio motore, Mounting the motor, Montage moteur,
Montage Motor, Montaje del motor, Montage motor.
E
Y
Montaggio accessori trasmissione, Mounting drive accessories,
Montage accessoires transmission, Montage Antriebszubehör,
Montaje de accesorios transmisión, Montage accessoires overbrenging.
F
Fissaggio staffe finecorsa (dx e sx), Fastening limit switch brackets (RH/LH),
Fixation étriers fin de course (drt et gch), Befestigung Bügel Anschläge (rechts und links),
Fijación abrazaderas final de carrera (der. e izq.),
Bevestiging stangen aanslag (rechts en links).
2 -
DEIMOS BT H QSC
Collegamento morsettiera, Terminal board wiring,
Connexion plaque à bornes, Anschluss Klemmleiste,
Conexión tablero de bornes, Aansluiting aansluitkast.
G
NC
NC
M
0V (-)
24V ~ (+)
COM
SWC
SWO
25W max.
ANT
0V(-)
24V ~(+)
NO
NC
NC
NC
NO
NO
SCA/2°CH
NO
NO
VSAFE ~(-)
VSAFE ~(+)
FAULT PHOT
COM
PED
COM
START/CLOSE
STOP
PHOT
BAR
OPEN
FAULT BAR
Led presenza alimentazione
Power ON LED
Del de présence de tension
LED Stromversorgung vorhanden
Led presencia de alimentación
Led aanwezigheid voeding
JP9
13 12
SCA
14 15
F2 3,15A T
Display + tasti programmazio
Display + programming keys ne
Display + Programmieru ngstasten
Pantalla + botones programación
Display + programmeringstoetsen
Connettore scheda opzionale
Optional board connector
Connecteur carte facultative
Steckverbinder Zusatzkarte
Conector de la tarjeta opcional
Connector optionele kaart
F1
1,6A T 230V
3,15A T 120V
Connettore programmatore palmare,
Palmtop programmer connector,
Connecteur programmateur de poche,
Steckverbinder Palmtop-Programmierer,
Conector del programador de bolsillo,
Connector programmeerbare palmtop
31 32 33 34
JP9
II
°
CH
14 15
1
H
24
Connection of 1 pair of non-tested photocells
Anschluss von einem Paar nicht überprüften Fotozellen
Conexión de 1 par fotocélulas no comprobadas
Aansluiting van 1 paar fotocellen anders dan “trusted device”
JP3
21 12 13
5
4
3
2
1
2
1
Rx 1 Tx 1
LOGICA test fotocellule OFF/ Photocell test LOGIC OFF
LOGIQUE essai photocellules Désactivée /
LOGIK Test Fotozellen OFF
LÓGICA prueba fotocélulas OFF / LOGICA test fotocellen OFF
DEIMOS BT H QSC -
3
language
x1
dir preset autoset o sc ind
AR sr ac rh lh
ITA fra deu eng esp
. . . . . .
o
SIMPLIFIED MENU
rh
: motor installed on the right lh ar
: motor installed on the left
: automatic operation,
residential sr
: semiautomatic operation,
residential ac
: automatic operation,
commercial
Sc
: semiautomatic operation,
commercial
Ind
:dead man operation
PRESET
Master/Slave
Fixed code
Remote control programming
Gate open light or 2nd radio channel
START - CLOSE setting
Reversing motion
ICE
DEFAULT
PARAMETERS
Automatic
Closing Time
Slow-down speed
Opening motor torque
40
Closing motor torque
Speed during opening
Speed during closing
Partial opening
Zone
Slow-down distance
Opening deceleration space 10
Closing deceleration space 10
LOGIC
40
0
0
15
75
75
99
99
Automatic Closing Time
Block Pulses
Impulse lock TCA
3 step
Pre-alarm
Deadman
Photocells during opening
Photocell test
Safety edge testing
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
OFF
OFF
-
OFF ar
40
40
0
0
10
10
15
75
75
99
99
0
0 sr
40
15
75
75
99
99
40
10
10
0
0 ac
40
15
75
75
99
99
40
10
10
0
0 sc
40
15
75
75
99
99
40
10
10 ind
40
ON OFF ON OFF OFF
OFF OFF ON ON OFF
OFF OFF OFF OFF OFF
ON OFF ON OFF OFF
OFF OFF ON ON OFF
OFF OFF OFF OFF ON
ON ON ON ON OFF
OFF OFF OFF OFF OFF
OFF OFF OFF OFF OFF
OFF OFF OFF OFF OFF
OFF OFF OFF OFF OFF
ON ON ON ON ON
OFF OFF OFF OFF OFF
OFF OFF OFF OFF OFF
-
OFF OFF OFF OFF OFF
40
0
0
10
10
15
75
75
99
99
MIN 1 - MAX 3
AUTO OPEN
AUTO CLOSE
e re otes hidden button end release desidered button O 01
Scroll up
Scroll down
Exit Menù
DEIMOS BT H QSC -
5
K
6
40
37
12
L
28
22
160
43
22
131
249
118
M
CFZ
NO
CP
OK
CVZ
N
O
P
10 -
DEIMOS BT H QSC
O1
Q
88
88
P2
25
R
P1
S
S
88
88
SCHEDA DI ESPANSIONE
EXPANSION BOARD
CARTE EXPANSION
ERWEITERUNGSKARTE
TARJETA DE EXPANSIÓN
UITBREIDINGSKAART
UNIDA
Programmeerbare Universele Palmtop
Connessione seriale per ante contrapposte, Serial connection for opposite leaves, Connexion série pour vantaux opposés, Serieller Anschluss für einander entgegengesetzte Torflügel, Conexión serial para hojas contrapuestas, Seriële verbinding voor tegenovergestelde vleugels.
RX1 (PHOT) BAR2 BAR1 TX1 (PHOT)
T
M2
SLAVE zone
=128
aster
=OFF
TX2 (PHOT)
M1
MASTER
RX2 (PHOT) zone
=128
aster
=ON
27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1
JP2
27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1
JP2
JP1
TX TX RX RX
SCS1
JP1
TX TX RX RX
SCS1
Connessione Seriale Mediante Scheda Scs1 , Serial Connection Via Scs1 Card, Connexion Série À Travers La Carte Scs1, Serielle Verbindung Mit Karte Scs1,
Conexión Serial Mediante Tarjeta Scs1, Seriële Verbinding Middels Kaart Scs1.
SLAVE SLAVE MASTER
U
DEIMOS BT H QSC -
11
FOTOCELLULE
FOTOZELLEN
PHOTOCELLS
FOTOCÉLULAS
PHOTOCELLULES
FOTOCELLEN
COSTE
LEISTEN
27 26 25 24 23 22 21 20 19 18
COM
17 16 15 14 13 12
SAFETY EDGES
CANTOS
LINTEAUX
RANDEN
V
1
1-PHOT
13
12
1
2
TX1 RX1
3
4
1
2
5
13
12
21
24
13
25
21
12
13
4
3
2
1
6
5
Bar 1
1-BAR
A
2
17
16
1-PHOT
1
2
TX1 RX1
4
5
1
2
3
13
12
21
18
24
17
25
27
21
12
13
4
3
2
1
6
5
Bar 1
1-BAR
B
3
4
5
17
16
1
2
TX1
2-PHOT
17
16
1
2
TX2
17
16
3-PHOT
17
16
1
2
TX1
1
2
TX2
17
16
1
2
TX3
17
16
4-PHOT
17
16
1
2
TX1
1
2
TX2
17
16
1
2
TX3
17
16
1
2
TX4
RX1
RX2
3
4
1
2
5
3
4
1
2
5
13
12
21
24
13
12
18
21
RX1
RX2
RX3
3
4
1
2
5
3
4
1
2
5
3
4
1
2
5
13
12
21
24
13
12
2-SCS1-MA
1-SCS1-MA
13
12
3-SCS1-MA
18
21
RX1
RX2
RX3
RX4
3
4
1
2
5
3
4
1
2
5
3
4
1
2
5
3
4
1
2
5
13
12
21
24
13
12
2-SCS1-MA
1-SCS1-MA
13
12
3-SCS1-MA
5-SCS1-MA
4-SCS1-MA
13
12
6-SCS1-MA
18
21
17
4-SCS1-MA
5-SCS1-MA
12
13
17
25
21
12
13
17
1-SCS1-MA
2-SCS1-MA
12
13
17
25
21
12
13
17
21
27
12
13
17
25
21
12
13
4
3
2
1
6
5
Bar 1
4
3
2
1
6
5
Bar 2
4
3
2
1
6
5
Bar 1
4
3
2
1
6
5
Bar 2
3-BAR
2-BAR
17
21
27
6-SCS1-MA
12
13
4
3
2
1
6
5
Bar 3
4
3
2
1
6
5
Bar 1
4
3
2
1
6
5
Bar 2
4-BAR
17
4-SCS1-MA
5-SCS1-MA
3-SCS1-MA
12
13
17
21
27
6-SCS1-MA
12
13
4
3
2
1
6
5
Bar 3
4
3
2
1
6
5
Bar 4
C
D
E
Numero massimo dispositivi collegabili, Maximum number of devices that can be connected, Nombre maximum de dispositifs pouvant être connectés, Max. Anzahl der anschließbaren Geräte, Número máximo dispositivos que se pueden conectar, Maximum aantal aansluitbare inrichtingen.
FOTOCELLULE
PHOTOCELLULES
TEST BAR
=ON / TEST PHOT=ON
FOTOCÉLULAS
PHOTOCELLS
FOTOZELLEN
FOTOCELLEN
COSTE
LINTEAUX
CANTOS
SAFETY EDGES
3
E
LEISTEN
RANDEN
5
C
12 -
DEIMOS BT H QSC
ACCESS TO MENUS Fig. 1
logic radio
x 2
add. start
Add. 2ch erase 64
COD RX v para . 1 para . 2 para . . . .
logic. 1 logic. 2 logic. . . .
See PARAMETERS
MENU
See LOGIC
MENU
hidden button release desired button hidden button
PRG.
1 A 9 C
+/-
OK release desired button
2 2 F D OK 0 1 ok 01 ok 01
See RADIO
MENU
OK
Scroll up
Scroll down
Confirm/Switch on display
Exit Menù default language autoset
Opening
A
C
D
F
18 -
DEIMOS BT H QSC
PRG
ITA
- +
FRA
- +
DEU
- +
ENG
- + esp
OK
OK
OK
OK
OK stat
OK vers
OK bft . . .
+/-
- + n. cycles
OK
0000
+/-
- + n. Re otes OK
00
+/-
Fig.2
ped
STRE stop phot bar bar2 cls open svo svc set
Er01
Er02
Er05
Er1x
*
er3x
*
Er4x
*
Er5x
*
ER61
ErFx
*
DIAGNOSTICS and WARNINGS
DESCRIPTION NOTES
pedestrian input activated
START input activated
STOP input activated attivazione ingresso PHOT
SAFETY EDGE input activated
SAFETY EDGE input activated on slave motor
(opposite leaves connection)
CLOSE input activated
OPEN input activated opening limit switch input activated closing limit switch input activated the board is standing by to perform a complete opening-closing cycle uninterrupted by intermediate stops in order to acquire the torque required for movement.
WARNING! Obstacle detection function is not active
photocell test error safety edge test error safety edge test error on slave motor (opposite leaves connection) board hardware test error reverse due to obstacle thermal cutout error anomaly in communication w/ remote devices running off battery limit switch error check photocell connection and/or logic settings check safety edge connection and/or logic settings check safety edge connection and/or parameter/logic settings check connections to motor check for obstacles in path
Allow motor to cool check Scs1 serial connections
-check limit switch connections
* X = 0,1,…,9,A,B,C,D,E,F
35.40
Set torque threshold
Maximum instantaneous motor torque
F
E C
B
Closing
INSTALLER WARNINGS
WARNING! Important safety instructions. Carefully read and comply with all the warnings and instructions that come with the product as incorrect installation can cause injury to people and animals and damage to property. The warnings and instructions give important information regarding safety, installation, use and maintenance. Keep hold of instructions so that you can attach them to the technical file and keep them handy for future reference.
GENERAL SAFETY
This product has been designed and built solely for the purpose indicated herein.
Uses other than those indicated herein might cause damage to the product and create a hazard.
- The units making up the machine and its installation must meet the requirements of the following European Directives, where applicable: 2004/108/EC, 2006/95/
EC, 2006/42/EC, 89/106/EC, 99/05/EC and later amendments. For all countries outside the EEC, it is advisable to comply with the standards mentioned, in addition to any national standards in force, to achieve a good level of safety.
- The Manufacturer of this product (hereinafter referred to as the “Firm”) disclaims all responsibility resulting from improper use or any use other than that for which the product has been designed, as indicated herein, as well as for failure to apply Good Practice in the construction of entry systems (doors, gates, etc.) and for deformation that could occur during use.
- Installation must be carried out by qualified personnel (professional installer, according to EN 12635), in compliance with Good Practice and current code.
- Before commencing installation, check the product for damage.
- Before installing the product, make all structural changes required to produce safety gaps and to provide protection from or isolate all crushing, shearing and dragging hazard areas and danger zones in general. Check that the existing structure meets the necessary strength and stability requirements.
- The Firm is not responsible for failure to apply Good Practice in the construction and maintenance of the doors, gates, etc. to be motorized, or for deformation that might occur during use.
- Make sure the stated temperature range is compatible with the site in which the automated system is due to be installed.
- Do not install this product in an explosive atmosphere: the presence of flammable fumes or gas constitutes a serious safety hazard.
- Disconnect the electricity supply before performing any work on the system.
Also disconnect buffer batteries, if any are connected.
- Before connecting the power supply, make sure the product’s ratings match the mains ratings and that a suitable residual current circuit breaker and overcurrent protection device have been installed upline from the electrical system. Have the automated system’s mains power supply fitted with a switch or omnipolar thermal-magnetic circuit breaker with a contact separation of at least 3.0mm and any other equipment required by code.
- Make sure that upline from the mains power supply there is a residual current circuit breaker that trips at no more than 0.03A as well as any other equipment required by code.
- Make sure the earth system has been installed correctly: earth all the metal parts belonging to the entry system (doors, gates, etc.) and all parts of the system featuring an earth terminal.
- Installation must be carried out using safety devices and controls that meet standards EN 12978 and EN 12453.
- Impact forces can be reduced by using deformable edges.
- In the event impact forces exceed the values laid down by the relevant standards, apply electro-sensitive or pressure-sensitive devices.
- Apply all safety devices (photocells, safety edges, etc.) required to keep the area free of impact, crushing, dragging and shearing hazards. Bear in mind the standards and directives in force, Good Practice criteria, intended use, the installation environment, the operating logic of the system and forces generated by the automated system.
- Apply all signs required by current code to identify hazardous areas (residual risks). All installations must be visibly identified in compliance with the provisions of standard EN 13241-1.
- This product cannot be installed on leaves incorporating doors (unless the motor can be activated only when the door is closed).
- If the automated system is installed at a height of less than 2.5 m or is accessible, the electrical and mechanical parts must be suitably protected.
- Install any fixed controls in a position where they will not cause a hazard, away from moving parts. More specifically, hold-to-run controls must be positioned within direct sight of the part being controlled and, unless they are key operated, must be installed at a height of at least 1.5 m and in a place where they cannot be reached by the public.
- Apply at least one warning light (flashing light) in a visible position, and also attach a Warning sign to the structure.
- Attach a label near the operating device, in a permanent fashion, with information on how to operate the automated system’s manual release.
- Make sure that, during operation, mechanical risks are avoided or relevant protective measures taken and, more specifically, that nothing can be banged, crushed, caught or cut between the part being operated and surrounding parts.
- Once installation is complete, make sure the motor automation settings are correct and that the safety and release systems are working properly.
- Only use original spare parts for any maintenance or repair work. The Firm disclaims all responsibility for the correct operation and safety of the automated system if parts from other manufacturers are used.
- Do not make any modifications to the automated system’s components unless explicitly authorized by the Firm.
- Instruct the system’s user on what residual risks may be encountered, on the control systems that have been applied and on how to open the system manually in an emergency. give the user guide to the end user.
- Dispose of packaging materials (plastic, cardboard, polystyrene, etc.) in accordance with the provisions of the laws in force. Keep nylon bags and polystyrene out of reach of children.
WIRING
WARNING! For connection to the mains power supply, use: a multicore cable with a cross-sectional area of at least 5x1.5mm
2
or 4x1.5mm
2
when dealing with three-phase power supplies or 3x1.5mm
2
for single-phase supplies (by way of example, type H05 VV-F cable can be used with a cross-sectional area of 4x1.5mm
2
). To connect auxiliary equipment, use wires with a cross-sectional area of at least 0.5 mm
2
.
- Only use pushbuttons with a capacity of 10A-250V or more.
- Wires must be secured with additional fastening near the terminals (for example, using cable clamps) in order to keep live parts well separated from safety extra low voltage parts.
- During installation, the power cable must be stripped to allow the earth wire to be connected to the relevant terminal, while leaving the live wires as short as possible. The earth wire must be the last to be pulled taut in the event the cable’s fastening device comes loose.
WARNING! safety extra low voltage wires must be kept physically separate from low voltage wires.
Only qualified personnel (professional installer) should be allowed to access live parts.
CHECKING THE AUTOMATED SYSTEM AND MAINTENANCE
Before the automated system is finally put into operation, and during maintenance work, perform the following checks meticulously:
- Make sure all components are fastened securely.
- Check starting and stopping operations in the case of manual control.
- Check the logic for normal or personalized operation.
- For sliding gates only: check that the rack and pinion mesh correctly with 2 mm of play; keep the track the gate slides on clean and free of debris at all times.
- Check that all safety devices (photocells, safety edges, etc.) are working properly and that the anti-crush safety device is set correctly, making sure that the force of impact measured at the points provided for by standard EN 12445 is lower than the value laid down by standard EN 12453.
- Make sure that the emergency operation works, where this feature is provided.
- Check opening and closing operations with the control devices applied.
- Check that electrical connections and cabling are intact, making extra sure that insulating sheaths and cable glands are undamaged.
- While performing maintenance, clean the photocells’ optics.
- When the automated system is out of service for any length of time, activate the emergency release (see “EMERGENCY OPERATION” section) so that the operated part is made idle, thus allowing the gate to be opened and closed manually.
SCRAPPING
Materials must be disposed of in accordance with the regulations in force. There are no particular hazards or risks involved in scrapping the automated system. For the purpose of recycling, it is best to separate dismantled parts into like materials
(electrical parts - copper - aluminium - plastic - etc.).
DISMANTLING
If the automated system is being dismantled in order to be reassembled at another site, you are required to:
- Cut off the power and disconnect the whole electrical system.
- Remove the actuator from the base it is mounted on.
- Remove all the installation’s components.
- See to the replacement of any components that cannot be removed or happen to be damaged.
Anything that is not explicitly provided for in the installation manual is not allowed. The operator’s proper operation can only be guaranteed if the information given is complied with. The Firm shall not be answerable for damage caused by failure to comply with the instructions featured herein.
While we will not alter the product’s essential features, the Firm reserves the right, at any time, to make those changes deemed opportune to improve the product from a technical, design or commercial point of view, and will not be required to update this publication accordingly.
AVVERTENZE PER L’INSTALLATORE D811766_03
DEIMOS BT H QSC -
19
INSTALLATION MANUAL
1) FOREWORD
The DEIMOS BT H QSC actuator is highly versatile in terms of installation options due to the extremely low position of the pinion, the actuator’s compact nature and the height and depth adjustment features it offers. The adjustable electronic torque limiter provides anti-crush safety. Manual emergency operation is extremely easy to perform using just a knob.
Stopping at end of travel is controlled by electromechanical microswitches.
The built-in control panel controls the start relays and safety devices (photocells, safety edge) each time before performing any operation.
2) TECHNICAL SPECIFICATIONS
Power supply
MOTOR
single-phase 230V ±10%, 50Hz (*)
10) MANUAL RELEASE (See USER GUIDE -FIG.2-).
Warning Do not JERK the gate open and closed, instead push it GENTLY to the end of its travel.
----------------------------------------------------------
11) TERMINAL BOARD WIRING Fig. F-G
Once suitable electric cables have been run through the raceways and the automated device’s various components have been fastened at the predetermined points, the next step is to connect them as directed and illustrated in the diagrams contained in the relevant instruction manuals. Connect the live, neutral and earth wire (compulsory). The mains cable must be clamped in the relevant cable gland
(FIG.R-ref.P1), and the accessories’ wires in the cable gland (FIG.R-ref.P2), while the earth wire with the yellow/green-coloured sheath must be connected in the relevant terminal (FIG.R-ref.S).
Motor
Power input
Max. current demand
24V
70W
0,5A (230V~) - 1A (110V~)
TERMINAL DESCRIPTION
1-2
Motor connection.
3-4
5-6
24V transformer secondary windin (3-, 4+).
Closing limit switch SWC (5 Black common - 6 Red).
Pinion module 4mm (14 teeth)
5-7
8-9
Opening limit switch SWO (5 Black common -7 Brown).
Leaf speed
Max. leaf weight
Max. torque
Impact reaction
Lubrication
Manual operation
12m/min
5000N (≈500kg)
20Nm
Electronic torque limiter
Lifetime greased
Knob-operated mechanical release
Type of use
Buffer batteries (optional extras) intensive
Two 12V 1.2Ah batteries
Environmental conditions from -15°C to +40°C
Protection rating IP24
Noise level
Operator weight
<70dBA
7kg (≈70N)
Dimensions See Fig. K
CONTROL UNIT
Accessories power supply 24V ~ (180 mA)
Fuses Fig. G
Built-in Rolling-Code radio-receiver frequency 433.92MHz
Setting of parameters and options
N° of combinations
Max. n° of remotes that can be memorized
Universal handheld programmer/LCD display
4 billion
63
(*) Special supply voltages to order.
Usable transmitter versions:
All ROLLING CODE transmitters compatible with
3) TUBE ARRANGEMENT Fig.A
Install the electrical system referring to the standards in force for electrical systems CEI
64-8, IEC 364, harmonization document HD 384 and other national standards.
4) PREPARATION FOR MOTOR MOUNTING FIG.B
• Make a hole in the ground to accommodate the concrete pad, with anchors embedded in the base plate for fastening the gearbox assembly, keeping to the distances featured in FIG.B.
• To keep the base plate in the right position during installation, it may be useful to weld two iron plates under the track to which the anchors can then be welded (FIG.M).
5) MOUNTING THE MOTOR FIG.C
10-11
12-13
14-15
16-17
18
19-20
21-22
21-23
21-24
21-25
21-26
27
31-32
33-34
Flashing light 24V max. 25W.
Antenna (10 signal - 11 braiding).
Use an antenna tuned to 433MHz.
Use RG58 coax cable to connect the Antenna and Receiver.
Metal bodies close to the antenna can interfere with radio reception. If the transmitter’s range is limited, move the antenna to a more suitable position.
Accessories power supply:
24 V operation with mains power on.
24 V (12-,13+) operation with no mains power and optional buffer battery kit.
Free contact (NO).
Gate Open Light SCA (24V max. 3W) or 2nd radio channel output
(FIG.G-ref.1).
This option can be set via the “logic menu”.
Safety device power supply output (photocell transmitter and safety edge transmitter).
N.B.: output active only during operating cycle.
24 V Vsafe operation with mains power on.
24 V (16 -,17+) Vsafe operation with no mains power and optional buffer battery kit.
Safety device test input FAULT - PHOT (N.O.).
PEDESTRIAN control button (N.O.)
Opens the gate by the distance set with the “Partial Opening” parameter
START/CLOSE control button (N.O.). This option can be set via the “logic menu”. Start - operation according to 3/4-step logic
Close - The command causes the leaf to close.
STOP input (N.C.)
The command stops movement.
If not used, leave jumper inserted.
PHOTOCELL input (N.C.)
Operation according to photocell during opening logic.
If not used, leave jumper inserted.
Safety edge input BAR (NC).
The command reverses movement for 2 secs.
If not used, leave jumper inserted.
OPEN control button (N.O.).
Gate opened with this command.
Safety device test input FAULT - BAR
230V~ transformer primary winding.
Single-phase power supply 230V, 50-60Hz (33N - 34L).
12) SAFETY DEVICES
NOTE: ONLY USE RECEIVING SAFETY DEVICES WITH FREE CHANGEOVER
CONTACT.
12.1) TESTED DEVICES (FIG. U)
12.2) NON-TESTED DEVICES (FIG. H, U)
6) MOUNTING DRIVE ACCESSORIES FIG.D-D1
7) RACK CENTRING WITH RESPECT TO PINION FIG.N-O1-P
DANGER - Welding must be performed by a competent person issued with the necessary personal protective equipment as prescribed by the safety rules in force FIG.O.
8) FASTENING LIMIT SWITCH BRACKETS FIG.E
9) STOPS FIG.Q
DANGER - The gate must be fitted with mechanical stops to halt its travel both when opening and closing, thus preventing the gate from coming off the top guide. Said stops must be fastened firmly to the ground, a few centimetres beyond the electric stop point.
20 -
DEIMOS BT H QSC
13) CALLING UP MENUS: FIG. 1
13.1) PARAMETERS MENU (PARA ) (PARAMETERS TABLE “A”)
13.2) LOGIC MENU (LOGIC) (LOGIC TABLE “B”)
13.3) RADIO MENU (radio) (RADIO TABLE “C”)
- IMPORTANT NOTE: THE FIRST TRANSMITTER MEMORIZED MUST BE
IDENTIFIED BY ATTACHING THE KEY LABEL (MASTER).
In the event of manual programming, the first transmitter assigns the RECEIVER’S
KEY CODE: this code is required to subsequently clone the radio transmitters.
The Clonix built-in on-board receiver also has a number of important advanced features:
• Cloning of master transmitter (rolling code or fixed code).
• Cloning to replace transmitters already entered in receiver.
• Transmitter database management.
• Receiver community management.
INSTALLATION MANUAL
To use these advanced features, refer to the universal handheld programmer’s instructions and to the general receiver programming guide.
13.4) LANGUAGE MENU (language)
Used to set the programmer’s language on the display.
13.5) DEFAULT MENU (default)
Restores the controller’s DEFAULT factory settings. Following this reset, you will need to run the AUTOSET function again.
13.6) AUTOSET MENU (AUTOset)
• Launch an autoset operation by going to the relevant menu on the panel.
• As soon as you press the OK button, the “.... .... ....” message is displayed and the control unit commands the door to perform a full cycle (opening followed by closing), during which the minimum torque value required for the door to move is set automatically.
The number of cycles required for the autoset function can range from 1 to 3.
During this stage, it is important to avoid breaking the photocells’ beams and not to use the START and STOP commands or the display.
Once this operation is complete, the control unit will have automatically set the optimum torque values. Check them and, where necessary, edit them as described in the programming section.
WARNING: Check that the force of impact measured at the points provided for by standard EN 12445 is lower than the value laid down by standard EN 12453.
Warning!! While the autoset function is running, the obstacle detection function is not active. Consequently, the installer must monitor the automated system’s movements and keep people and property out of range of the automated system.
14)CONNECTION WITH EXPANSION BOARDS AND UNIVERSAL HANDHELD
PROGRAMMER (Fig.S)
Refer to specific manual.
15) SCS OPTIONAL MODULES
15.1) SERIAL CONNECTION VIA SCS1 CARD (Fig. U)
The control panel’s special serial inputs and outputs (SCS1) make the centralized connection of a number of automated devices possible. That way, all the automated devices connected can be opened or closed with a single command.
Connect all control panels using twisted pair cabling only, proceeding as shown in the diagram in Fig. U.
When using a telephone cable with more than one pair, it is essential to use wires from the same pair.
The length of the telephone cable between one unit and the next must not be greater than 250 m.
At this point, each control panel needs to be configured appropriately, starting by entering a MASTER control panel that will have control over all the others, which therefore have to be set as SLAVE units (see logic menu).
Also set the Zone number (see parameters menu) in the range 0 to 127.
The zone number allows you to create groups of automated devices, each of which answers to the Zone Master. Each zone can have only one Master: the Master of zone 0 also controls the Slaves of the other zones. Warning: the control panel set as the MASTER must be the first in the series.
15.2) Opposite sliding leaves (Fig. T)
By means of a serial connection, it is also possible to obtain centralised control of two opposite barriers/gates.
In this case, the Master M1 control panel will simultaneously manage closing and opening for the Slave M2 control panel.
SETTING REQUIRED FOR OPERATION:
- MASTER board: zone=128, aster=ON
- SLAVE board: zone=128, aster=OFF
WIRING REQUIRED FOR OPERATION:
- The MASTER and SLAVE control units are interconnected through the 4 wires
(RX/TX) for the SCS1 interface boards;
- All the activation controls, as well as the remote controls must refer to the
MASTER board;
- All the photocells (checked or unchecked) must be connected to the MASTER control panel;
- The safety edges (checked or unchecked) of the MASTER leaf must be connected to the MASTER control unit;
- The safety edges (checked or unchecked) of the SLAVE leaf must be connected to the SLAVE control unit.
15.3) EXPANDING OUTPUTS FOR SAFETY DEVICE TESTING VIA SCS-MA
BOARD (FIG. V)
When testing more than 2 devices (Ref. 4, 5, D, E Fig. V), the SCS-MA auxiliary board must be used.
15.4) Interface with WIEGAND systems via SCS-WIE module.
Refer to the SCS-WIE module’s instructions.
13.1) TABLE A: PARAMETERS MENU (PARA )
Parameter min. max. default personal Definition Description
tca
0 120 40
Automatic
Closing Time
Automatic closing time [s] slov speed
15 50 15
Slow-down speed
Slow-down speed [%] (Fig.2 Rif. F)
Set the speed the gate must reach slowing down, in percentage to the actuator’s maximum speed.
WARNING:
should this parameter be edited, it will be followed by a complete opening/closing cycle for setting purposes (reported by the message “SET” appearing on the display), during which obstacle detection is not enabled.
op.t slov cls.t
slov op speed cl speed partial opening
1
1
15
15
10
99
99
99
99
99
75
75
99
99
40
Opening motor torque
Closing motor torque
Speed during opening
Speed during closing
Partial opening
Opening torque [%]
Sets sensitivity to obstacles during opening (1=min., 99=mx.) The autoset feature sets this parameter automatically to a value of 10%. The user can edit this parameter based on how sensitive the door needs to be to obstacles.
Closing torque [%]
Sets sensitivity to obstacles during closing (1=min., 99=mx.) The autoset feature sets this parameter automatically to a value of 10%. The user can edit this parameter based on how sensitive the door needs to be to obstacles.
Running speed during opening [%] (Fig. 2 Rif. A)
Sets the running speed that the door must reach during opening, as a percentage of the maximum speed the actuator can reach.
WARNING:
should this parameter be edited, it will be followed by a complete opening/closing cycle for setting purposes (reported by the message “SET” appearing on the display), during which obstacle detection is not enabled.
Running speed during closing [%] (Fig. 2 Rif. B)
Sets the running speed that the door must reach during closing, as a percentage of the maximum speed the actuator can reach. The autoset feature sets this parameter automatically.
WARNING:
should this parameter be edited, it will be followed by a complete opening/closing cycle for setting purposes
(reported by the buzzer emitting a continuous beeping sound and the message SET appearing on the display), during which obstacle detection is not enabled.
Partial opening [%]
Adjusts partial opening percentage compared to total opening in “Partial open” mode.
zone dist.
decel
(special par
18*) op.dist.
decel
(special par
19*) cl.dist.
decel
(special par
20*)
0
0
5
5
128
50
50
50
0
0
10
10
Zone
Slow-down distance
Opening deceleration space
Closing deceleration space
Zone []
Sets the zone number of the door included in the serial connection for commands via central controllers. Zone 128: Serial connection for opposite Sliding Leaves.
Slow-down distance [%] (Fig.2 Rif. C)
Set the distance the gate needs to go from from high to low speed in percentage to total travel.
WARNING:
should this parameter be edited, it will be followed by a complete opening/closing cycle for setting purposes (reported by the message “SET” appearing on the display), during which obstacle detection is not enabled.
Opening deceleration space [%] (Fig.2 Rif. D)
Set the opening slow-down distance in percentage to total travel. This distance is covered at low speed.
WARNING:
should this parameter be edited, it will be followed by a complete opening/closing cycle for setting purposes (reported by the message “SET” appearing on the display), during which obstacle detection is not enabled.
Closing slow-down distance [%] (Fig.2 Rif. E)
Set the closing slow-down distance in percentage to total travel. This distance is covered at low speed.
WARNING:
should this parameter be edited, it will be followed by a complete opening/closing cycle for setting purposes (reported by the message “SET” appearing on the display), during which obstacle detection is not enabled.
*=Refer for universal handheld programmer.
DEIMOS BT H QSC -
21
INSTALLATION MANUAL
13.2) TABLE “B” - LOGIC MENU - (logic)
Logic Default Definition Description
TCA
Ibl open ibl TCA
3 step
OFF
OFF
Automatic Closing
Time
Opening Impulse lock
OFF Impulse lock TCA
OFF 3 step
ON
Activates automatic closing
OFF
Excludes automatic closing
ON
The Start impulse has no effect during the opening phase.
OFF
The Start impulse becomes effective during the opening phase.
ON The Start impulse has no effect during the TCA dwell period.
OFF The Start impulse becomes effective during the TCA dwell period.
A start impulse has the following effects:
ON Switches to 3-step logic.
closed on closing
3 steps
opens
4 steps
opens stop
OFF Switches to 4-step logic.
open on opening after stop closes stop + TCA opens closes stop + TCA opens
preal start - close
ICE
(special dip 2*)
OFF Pre-alarm
hold to run
OFF Deadman
Photoc. open
OFF
test phot test bar ster fixed code radio prog
SCA 2Ch change ot.
OFF
ON
OFF
OFF
Photocells during opening
OFF Photocell test
Safety edge testing
OFF Master/slave
OFF Fixed code
Remote control programming
Gate open light or
2nd radio channel
START - CLOSE setting
OFF Reversing motion
OFF ICE
ON The flashing light comes on approx. 3 seconds before the motors start.
OFF The flashing light comes on at the same time as the motors start.
ON
Hold-to-run operation: the manoeuvre continues as long as the OPEN and CLOSE control keys are kept pressed. The radio transmitter cannot be used.
OFF Normal impulse operation.
ON
When beam is broken, operation of the photocell is switched off during opening. During closing, movement is reversed immediately.
OFF
ON
OFF
When beam is broken, photocells are active during both opening and closing. When beam is broken during closing, movement is reversed only once the photocell is cleared.
Switches photocell testing on
Switches photocell testing off
If disabled (OFF), it inhibits the photocell testing function, enabling connection of devices not equipped with supplementary test contacts.
Switches safety edge testing on.
ON
OFF
Switches safety edge testing off
If disabled (OFF), it inhibits the safety edge testing function, enabling connection of devices not equipped with supplementary test contacts.
ON Control panel is set up as the Master unit in a centralized serial connection system.
OFF Control panel is set up as a Slave unit in a centralized serial connection system.
ON Receiver is configured for operation in fixed-code mode.
OFF Receiver is configured for operation in rolling-code mode.
ON
Enables wireless memorizing of transmitters:
1- Press in sequence the hidden key (P1) and normal key (T1-T2-T3-T4) of a transmitter that has already been memorized in standard mode via the radio menu.
2- Press within 10 secs. the hidden key (P1) and normal key (T1-T2-T3-T4) of a transmitter to be memorized.
IMPORTANT: Enables the automatic addition of new transmitters, clones and replays.
The receiver exits programming mode after 10 secs.: you can use this time to enter other new transmitters. This mode does not require access to the control panel.
OFF
Disables wireless memorizing of transmitters.
Transmitters are memorized only using the relevant Radio menu.
IMPORTANT: Disables the automatic addition of new transmitters, clones and replays.
ON
The output between terminals 14-15 is set as Gate open light: in this case, the 2nd radio channel controls pedestrian opening.
OFF The output between terminals 14-15 is set as 2nd radio channel.
ON Input between terminals 21-22 works as CLOSE.
OFF Input between terminals 21-22 works as START.
ON Change this parameter if the opening direction needs to be changed
OFF Standard operating mode.
ON
The controller automatically adjusts the Amperostop safety trip threshold. Check that the force of impact
measured at the points provided for by standard EN 12445 is lower than the value laid down by standard
EN 12453. If in doubt, use auxiliary safety devices. This feature is useful when dealing with installations running at low temperatures.
WARNING: once this feature has been activated, you will need to perform an autoset opening and closing cycle.
OFF The Amperostop safety trip threshold stays at the same set value.
*=Refer for universal handheld programmer.
13.3) TABLE C: RADIO MENU (RADIO)
Logic
Description
Add start
Add Start Key associates the desired key with the Start command.
add 2ch
Add 2ch Key associates the desired key with the 2nd radio channel command.
erase 64
Erase List WARNING! Erases all memorized remote controls from the receiver’s memory.
Read receiver code Displays receiver code required for cloning remote controls.
ON = Enables remote programming of cards via a previously memorized W LINK transmitter. It remains enabled for 3 minutes from the time the
W LINK remote control is last pressed.
OFF= W LINK programming disabled.
22 -
DEIMOS BT H QSC
MANUALE D’USO: MANOVRA MANUALE/ USER’S MANUAL: MANOVRA MANUALE/ MANUEL D’UTILISATION: MANOVRA MANUALE/ BE-
DIENUNGSANLEITUNG: MANOVRA MANUALE/ MANUEL DE USO: MANOVRA MANUALE/ MANUAL PARA DE USO: MANOVRA MANUALE
FIG. 2
A E
CLOSE
(90°)
OPEN
B
C
D
OPEN
(90°)
CLOSE
AVVERTENZE PER L’UTILIZZATORE ( I )
ATTENZIONE! Importanti istruzioni di sicurezza. Leggere e seguire attentamente le Avvertenze e le Istruzioni che accompagnano il prodotto poiché un uso improprio può causare danni a persone, animali o cose. Conservare le istruzioni per consultazioni future e trasmetterle ad eventuali subentranti nell’uso dell’impianto.
Questo prodotto dovrà essere destinato solo all’uso per il quale è stato espressamente installato. Ogni altro uso è da considerarsi improprio e quindi pericoloso. Il costruttore non può essere considerato responsabile per eventuali danni causati da usi impropri, erronei e irragionevoli.
SICUREZZA GENERALE
Nel ringraziarVi per la preferenza accordata a questo prodotto, la Ditta è certa che da esso otterrete le prestazioni necessarie al Vostro uso.
Questo prodotto risponde alle norme riconosciute della tecnica e della disposizioni relative alla sicurezza se correttamente installato da personale qualificato ed esperto (installatore professionale).
L’automazione, se installata ed utilizzata correttamente, soddisfa gli standard di sicurezza nell’uso. Tuttavia è opportuno osservare alcune regole di comportamento per evitare inconvenienti accidentali:
- Tenere bambini, persone e cose fuori dal raggio d’azione dell’automazione, in particolare durante il movimento.
- Non permettere a bambini di giocare o sostare nel raggio di azione dell’automazione.
- Questa automazione non è destinata all’uso da parte di bambini o da parte di persone con ridotte capacità mentali, fisiche e sensoriali, o persone che mancano di conoscenze adeguate.
- Evitare di operare in prossimità delle cerniere o organi meccanici in movimento.
- Non contrastare il movimento dell’anta e non tentare di aprire manualmente la porta se non è stato sbloccato l’attuatore con l’apposita manopola di sblocco.
- Non entrare nel raggio di azione della porta o cancello motorizzati durante il loro movimento.
- Non lasciare radiocomandi o altri dispositivi di comando alla portata dei bambini onde evitare azionamenti involontari.
- L’attivazione dello sblocco manuale potrebbe causare movimenti incontrollati della porta se in presenza di guasti meccanici o di condizioni di squilibrio.
- In caso di apritapparelle: sorvegliare la tapparella in movimento e tenere lontano le persone finché non è completamente chiusa. Porre cura quando si aziona lo sblocco se presente, poiché una tapparella aperta potrebbe cadere rapidamente in presenza di usura o rotture.
- La rottura o l’usura di organi meccanici della porta (parte guidata), quali ad esempio cavi, molle, supporti, cardini, guide.. potrebbe generare pericoli. Far controllare periodicamente l’impianto da personale qualificato ed esperto (installatore professionale) secondo quanto indicato dall’installatore o dal costruttore della porta.
- Per ogni operazione di pulizia esterna, togliere l’alimentazione di rete.
- Tenere pulite le ottiche delle fotocellule ed i dispositivi di segnalazione luminosa.
Controllare che rami ed arbusti non disturbino i dispositivi di sicurezza.
- Non utilizzare l’automatismo se necessita di interventi di riparazione. In caso di guasto o di malfunzionamento dell’automazione, togliere l’alimentazione di rete sull’automazione, astenersi da qualsiasi tentativo di riparazione o intervento diretto e rivolgersi solo a personale qualificato ed esperto (installatore professionale) per la necessaria riparazione o manutenzione. Per consentire l’accesso, attivare lo sblocco di emergenza (se presente).
- Per qualsiasi intervento diretto sull’automazione o sull’impianto non previsto dal presente manuale, avvalersi di personale qualificato ed esperto (installatore
DEIMOS BT H QSC -
43
professionale).
- Con frequenza almeno annuale far verificare l’integrità e il corretto funzionamento dell’automazione da personale qualificato ed esperto (installatore professionale), in particolare di tutti i dispositivi di sicurezza.
- Gli interventi d’installazione, manutenzione e riparazione devono essere documentati e la relativa documentazione tenuta a disposizione dell’utilizzatore.
- Il mancato rispetto di quanto sopra può creare situazioni di pericolo.
Tutto quello che non è espressamente previsto nel manuale d’uso, non è permesso. ll buon funzionamento dell’operatore è garantito solo se vengono rispettate le prescrizioni riportate in questo manuale. La Ditta non risponde dei danni causati dall’inosservanza delle indicazioni riportate in questo manuale.
Lasciando inalterate le caratteristiche essenziali del prodotto, la Ditta si riserva di apportare in qualunque momento le modifiche che essa ritiene convenienti per migliorare tecnicamente, costruttivamente e commercialmente il prodotto, senza impegnarsi ad aggiornare la presente pubblicazione.
USER WARNINGS (GB)
WARNING! Important safety instructions. Carefully read and comply with the Warnings and Instructions that come with the product as improper use can cause injury to people and animals and damage to property. Keep the instructions for future reference and hand them on to any new users.
This product is meant to be used only for the purpose for which it was explicitly installed. Any other use constitutes improper use and, consequently, is hazardous. The manufacturer cannot be held liable for any damage as a result of improper, incorrect or unreasonable use.
GENERAL SAFETY
Thank you for choosing this product. The Firm is confident that its performance will meet your operating needs.
This product meets recognized technical standards and complies with safety provisions when installed correctly by qualified, expert personnel (professional installer).
If installed and used correctly, the automated system will meet operating safety standards. Nonetheless, it is advisable to observe certain rules of behaviour so that accidental problems can be avoided:
- Keep adults, children and property out of range of the automated system, especially while it is moving.
- Do not allow children to play or stand within range of the automated system.
- This automated system is not meant for use by children or by people with impaired mental, physical or sensory capacities, or people who do not have suitable knowledge.
- Do not work near hinges or moving mechanical parts.
- Do not hinder the leaf’s movement and do not attempt to open the door manually unless the actuator has been released with the relevant release knob.
- Keep out of range of the motorized door or gate while they are moving.
- Keep remote controls or other control devices out of reach of children in order to avoid the automated system being operated inadvertently.
- The manual release’s activation could result in uncontrolled door movements if there are mechanical faults or loss of balance.
- When using roller shutter openers: keep an eye on the roller shutter while it is moving and keep people away until it has closed completely. Exercise care when activating the release, if such a device is fitted, as an open shutter could drop quickly in the event of wear or breakage.
- The breakage or wear of any mechanical parts of the door (operated part), such as cables, springs, supports, hinges, guides…, may generate a hazard. Have the system checked by qualified, expert personnel (professional installer) at regular intervals according to the instructions issued by the installer or manufacturer of the door.
- When cleaning the outside, always cut off mains power.
- Keep the photocells’ optics and illuminating indicator devices clean. Check that no branches or shrubs interfere with the safety devices.
- Do not use the automated system if it is in need of repair. In the event the automated system breaks down or malfunctions, cut off mains power to the system; do not attempt to repair or perform any other work to rectify the fault yourself and instead call in qualified, expert personnel (professional installer) to perform the necessary repairs or maintenance. To allow access, activate the emergency release (where fitted).
- If any part of the automated system requires direct work of any kind that is not contemplated herein, employ the services of qualified, expert personnel
(professional installer).
- At least once a year, have the automated system, and especially all safety devices, checked by qualified, expert personnel (professional installer) to make sure that it is undamaged and working properly.
- A record must be made of any installation, maintenance and repair work and the relevant documentation kept and made available to the user on request.
- Failure to comply with the above may result in hazardous situations.
Anything that is not explicitly provided for in the user guide is not allowed.
The operator’s proper operation can only be guaranteed if the instructions given herein are complied with. The Firm shall not be answerable for damage caused by failure to comply with the instructions featured herein.
While we will not alter the product’s essential features, the Firm reserves the right, at any time, to make those changes deemed opportune to improve the product from a technical, design or commercial point of view, and will not be required to update this publication accordingly.
44 -
DEIMOS BT H QSC
AVERTISSEMENTS POUR L’UTILISATEUR (F)
ATTENTION ! Instructions de sécurité importantes. Veuillez lire et suivre attentivement tous les avertissements et toutes les instructions fournis avec le produit sachant qu’un usage incorrect peut provoquer des préjudices aux personnes, aux animaux ou aux biens. Veuillez conserver les instructions pour d’ultérieures consultations et pour les transmettre aux propriétaires futurs éventuels.
Cet appareil ne peut être destiné qu’à l’usage pour lequel il a été expressément installé. Tout autre usage sera considéré comme impropre et donc dangereux. Le fabricant ne sera en aucun cas considéré comme responsable des préjudices dus à un usage impropre, erroné ou déraisonné.
SECURITE GÉNÉRALE
Nous vous remercions d’avoir choisi ce produit qui, nous n’en doutons pas, saura vous garantir les performances attendues.
Ce produit, correctement installé par du personnel qualifié et expérimenté
(monteur professionnel) est conforme aux normes reconnues de la technique et des prescriptions de sécurité.
Si l’automatisation est montée et utilisée correctement, elle garantit la sécurité d’utilisation prescrite. Il est cependant nécessaire de respecter certaines règles de comportement pour éviter tout inconvénient accidentel.
- Tenir les enfants, les personnes et les objets à l’écart du rayon d’action de l’automatisation, en particulier pendant son fonctionnement.
- Empêcher les enfants de jouer ou de stationner dans le rayon d’action de l’automatisation.
- Cette automatisation n’est pas conçue pour être utilisée par des enfants, des personnes ayant un handicap mental, physique ou sensoriel ou des personnes dépourvues des connaissances nécessaires.
- Eviter d’opérer à proximité des charnières ou des organes mécaniques en mouvement.
- Ne pas s’opposer volontairement au mouvement du vantail et ne pas tenter d’ouvrir la porte à la main si le déclencheur n’est pas déverrouillé avec le levier de déverrouillage prévu à cet effet.
- Ne pas entrer dans le rayon d’action du portail/de la porte motorisé/e pendant son mouvement.
- Ranger les radiocommandes ou les autres dispositifs de commande hors de portée des enfants afin d’éviter tout actionnement involontaire.
- L’activation du déverrouillage manuel risque de provoquer des mouvements incontrôlés de la porte en présence de pannes mécaniques ou de conditions de déséquilibre.
- Avec les ouvre-stores: surveiller le store en mouvement et veiller à ce que les personnes restent à l’écart tant qu’il n’est pas complètement fermé. Actionner l’éventuel déverrouillage avec prudence car si un store reste ouvert il peut tomber brutalement s’il est usé ou cassé.
- La rupture ou l’usure des organes mécaniques de la porte (partie guidée), tels que les câbles, les ressorts, les supports et les gonds peuvent générer des risques.
Faire contrôler périodiquement l’installation par du personnel qualifié et expérimenté (monteur professionnel), conformément aux indications du monteur ou du fabricant de la porte.
- Mettre hors tension avant d’accomplir les opérations de nettoyage extérieur.
- Veiller à la propreté des lentilles des photocellules et des lampes de signalisation.
Veiller à ce que les dispositifs de sécurité ne soient pas gênés par des branches ou des arbustes.
- Ne pas utiliser l’automatisation si elle a besoin d’être réparée. En cas de panne ou de mauvais fonctionnement de l’automatisation, mettre l’automatisation hors tension, éviter toute tentative de réparation ou d’intervention directe et s’adresser uniquement à du personnel qualifié et expérimenté (monteur professionnel) pour la réparation ou les opérations d’entretien nécessaires. Pour permettre l’accès, activer le déverrouillage d’urgence (s’il y en a un).
- Pour toutes les interventions directes sur l’automatisation ou sur l’installation non prévues dans le présent manuel, s’adresser uniquement à du personnel qualifié et expérimenté (monteur professionnel).
- Une fois par an au moins, faire vérifier le bon état et le bon fonctionnement de l’automatisation par du personnel qualifié et expérimenté (monteur professionnel) et en particulier tous les dispositifs de sécurité.
- Les interventions de montage, d’entretien et de réparation doivent être documentées et cette documentation doit être tenue à la disposition de l’utilisateur.
- Le non respect des prescriptions ci-dessus peut être à l’origine de dangers.
Tout ce qui n’est pas expressément prévu dans le manuel de montage est interdit. Le bon fonctionnement de l’appareil n’est garanti que si les données indiquées sont respectées. Le Fabricant ne répond pas des dommages provoqués par l’inobservation des indications données dans ce manuel.
En laissant inaltérées les caractéristiques essentielles de l’appareil, l’entreprise se réserve le droit d’apporter à tout moment les modifications qu’elle jugera opportunes pour améliorer le produit du point de vue technique, commercial et de sa construction, sans s’engager à mettre à jour la présente publication.
HINWEISE FÜR DEN BENUTZER (D)
ACHTUNG! Wichtige Hinweise zur Sicherheit. Bitte lesen und befolgen Sie aufmerksam die Hinweise sowie die Bedienungsanleitung, die das Produkt begleiten, denn eine falsche Benutzung des Produkts kann zu Verletzungen von Menschen und Tieren sowie zu Sachschäden führen. Bitte bewahren
Sie die Anweisungen für die zukünftige Konsultation sowie für eventuelle zukünftige Benutzer der Anlage auf.
Dieses Produkt ist ausschließlich für den Einsatz bestimmt, für den es ausdrücklich installiert worden ist. Alle sonstigen Einsatzweisen gelten als
Zweckentfremdung und somit als gefährlich. Der Hersteller kann nicht für eventuelle Schäden haftbar gemacht werden, die auf Zweckentfremdung oder unsachgemäße Verwendung zurückzuführen sind.
ALLGEMEINE SICHERHEIT
Wir danken Ihnen dafür, dass Sie diesem Produkt den Vorzug gegeben haben, und sind sicher, dass Sie mit ihm die für Ihre Anwendung erforderlichen Leistungen erzielen werden.
Dieses Produkt entspricht den anerkannten Normen der Technik sowie den Sicherheitsbestimmungen, falls es von qualifiziertem Fachpersonal (professioneller
Installateur) ordnungsgemäß installiert wird.
Bei ordnungsgemäßer Installation und Benutzung erfüllt die Automatisierung die geforderten Sicherheitsstandards. Dennoch sollten einige Verhaltensregeln beachtet werden, um Zwischenfälle zu vermeiden:
- Halten Sie Kinder, Personen und Sachen aus dem Wirkungsbereich der Automatisierung fern, vor allem während der Bewegung.
- Verhindern Sie, dass sich Kindern im Aktionsradius der Automatisierung aufhalten oder dort spielen.
- Diese Automatisierung ist nicht für die Benutzung durch Kinder oder Personen mit eingeschränkten geistigen oder körperlichen Fähigkeiten sowie Personen ohne ausreichende Kenntnisse bestimmt.
- Vermeiden Sie Arbeiten in der Nähe der Scharniere oder der beweglichen Bauteile.
- Halten Sie die Bewegung der Tür nicht auf und versuchen Sie nicht, die Tür von
Hand zu öffnen, wenn der Trieb nicht mit dem entsprechenden Entsperrhebel entsperrt worden ist.
- Halten Sie sich während der Bewegung aus dem Aktionsradius der Tür oder des motorisierten Tors fern.
- Halten Sie die Funkfernbedienung oder sonstige Steuerungsvorrichtungen von Kindern fern, um unbeabsichtigte Betätigungen der Automatisierung zu vermeiden.
- Die Aktivierung der manuellen Entsperrung könnte bei mechanischen Defekten oder Ungleichgewichtssituationen zu unkontrollierten Bewegungen der Tür führen.
- Bei Rollladenautomatisierungen: Überwachen Sie den Rollladen während der
Bewegung und halten Sie Personen fern, bis er vollständig geschlossen ist.
Gehen Sie bei der Betätigung der eventuellen Entsperrung mit Vorsicht vor, da der offene Rollladen bei Brüchen oder Abnutzung herunterfallen könnte.
- Das Brechen oder die Abnutzung der mechanischen Organe der Tür (geführter
Teil) wie zum Beispiel Kabel, Federn, Aufhängungen, Führungen usw. könnte zu Gefahren führen. Lassen Sie die Anlage in regelmäßigen Abständen von qualifiziertem Fachpersonal (professioneller Installateur) unter Beachtung der
Angaben des Installateurs oder des Herstellers der Tür überprüfen.
- Unterbrechen Sie vor allen externen Reinigungsarbeiten die Stromversorgung.
- Halten Sie die Linsen der Fotozellen und die Anzeigevorrichtungen sauber. Stellen
Sie sicher, dass die Sicherheitsvorrichtungen nicht durch Zweige oder Sträucher beeinträchtigt werden.
- Benutzen Sie die Automatisierung nicht, falls sie Reparatureingriffe erforderlich macht. Unterbrechen Sie bei Beschädigungen oder Funktionsstörungen die
Stromversorgung der Automatisierung, unternehmen Sie keine Reparaturversuche oder direkte Eingriffe und wenden Sie sich für die erforderliche Reparatur oder
Wartung an qualifiziertes Fachpersonal (professioneller Installateur). Aktivieren
Sie für den Zugang die Notfallentsperrung (falls vorhanden).
- Wenden Sie sich für alle im vorliegenden Handbuch nicht vorgesehenen direkten
Eingriffe an der Automatisierung oder der Anlage an qualifiziertes Fachpersonal
(professioneller Installateur).
- Lassen Sie die Unversehrtheit und den ordnungsgemäßen Betrieb der Automatisierung sowie insbesondere der Sicherheitsvorrichtungen zumindest einmal jährlich von qualifiziertem Fachpersonal (professioneller Installateur)
überprüfen.
- Die Installations-, Wartungs- und Reparatureingriffe müssen dokumentiert werden und die Dokumentation muss dem Benutzer zur Verfügung gehalten werden.
- Die Nichtbeachtung dieser Anweisung kann zu Gefahrensituationen führen.
Alles, was im Installationshandbuch nicht ausdrücklich vorgesehen ist, ist untersagt. Der ordnungsgemäße Betrieb des Triebs kann nur garantiert werden, wenn alle angegebenen Daten eingehalten werden. Die Firma haftet nicht für Schäden, die auf die Nichtbeachtung der Hinweise im vorliegenden
Handbuch zurückzuführen sind.
Unter Beibehaltung der wesentlichen Eigenschaften des Produktes kann die
Firma jederzeit und ohne Verpflichtung zur Aktualisierung des vorliegenden
Handbuches Änderungen zur technischen, konstruktiven oder handelstechnischen Verbesserung vornehmen.
ADVERTENCIAS PARA EL USUARIO (E)
¡ATENCIÓN! Instrucciones de seguridad importantes. Leer y seguir con atención las Advertencias y las Instrucciones que acompañan el producto, ya que el uso inapropiado puede causar daños a personas, animales o cosas.
Guardar las instrucciones para futuras consultas y transmitirlas a eventuales reemplazantes en el uso de la instalación.
Este producto se deberá utilizar únicamente para el uso para el cual ha sido expresamente instalado. Cualquier otro uso se considerará inadecuado y por lo tanto peligroso El fabricante no se responsabiliza por posibles daños causados debido a usos inapropiados, erróneos e irrazonables.
SEGURIDAD GENERAL
Le agradecemos por haber elegido este producto, en la Empresa estamos seguros que obtendrán las prestaciones necesarias para su uso.
Este producto responde a las normas reconocidas de la técnica y de las disposiciones inherentes a la seguridad siempre que haya sido correctamente instalado por personal cualificado y experto (instalador profesional).
La automatización, si se instala y utiliza de manera correcta, cumple con los estándares de seguridad para el uso. Sin embargo es conveniente respetar algunas reglas de comportamiento para evitar inconvenientes accidentales:
- Mantener a niños, personas y cosas fuera del radio de acción de la automatización, especialmente durante su movimiento.
- No permitir que los niños jueguen o permanezcan en el radio de acción de la automatización.
- Esta automatización no está destinada para ser utilizada por niños o por personas con capacidades mentales, físicas y sensoriales reducidas, o personas que no cuenten con conocimientos adecuados.
- Evitar operar cerca de las bisagras o de los órganos mecánicos en movimiento.
- No obstaculizar el movimiento de la hoja y no intentar abrir manualmente la puerta si no se ha desbloqueado el accionador con el botón de desbloqueo específico.
- No ingresar al radio de acción de la puerta o cancela motorizadas durante el movimiento de las mismas.
- No dejar radiomandos u otros dispositivos de mando al alcance de niños, para evitar accionamientos involuntarios.
- La activación del desbloqueo manual podría causar movimientos incontrolados de la puerta en caso de averías mecánicas o condiciones de desequilibrio.
- En caso de automatizaciones para persianas enrollables: vigilar la persiana en movimiento y mantener alejadas a las personas hasta que esté completamente cerrada. Tener precaución cuando se acciona el desbloqueo, si estuviera presente, puesto que una persiana enrollable abierta podría caer rápidamente en caso de desgaste o roturas.
- La rotura o el desgaste de órganos mecánicos de la puerta (parte guiada), como por ejemplo cables, muelles, soportes, goznes, guías, etc. podría generar peligros.
Hacer controlar periódicamente la instalación por personal cualificado y experto
(instalador profesional), según lo indicado por el instalador o por el fabricante de la puerta.
- Para cualquier operación de limpieza exterior, interrumpir la alimentación de red.
- Mantener limpias las ópticas de las fotocélulas y los dispositivos de señalización luminosa. Controlar que ramas y arbustos no obstaculicen los dispositivos de seguridad.
- No utilizar la automatización si necesita intervenciones de reparación. En caso de avería o de defecto de funcionamiento de la automatización, interrumpir la alimentación de red en la automatización, abstenerse de cualquier intento de reparación o intervención directa y recurrir sólo a personal cualificado y experto
(instalador profesional) para la necesaria reparación y mantenimiento. Para permitir el acceso, activar el desbloqueo de emergencia (si estuviera presente).
- Para cualquier intervención directa en la automatización o en la instalación no prevista por el presente manual, recurrir a personal cualificado y experto
(instalador profesional).
- Al menos una vez al año hacer controlar la integridad y el correcto funcionamiento de la automatización por personal cualificado y experto (instalador profesional), en particular de todos los dispositivos de seguridad.
- Las intervenciones de instalación, mantenimiento y reparación deben ser registradas y la documentación correspondiente se debe mantener a disposición del usuario.
- El incumplimiento de lo antes indicado puede provocar situaciones de peligro.
Todo aquello que no expresamente previsto en el manual de uso, no está permitido. El buen funcionamiento del operador es garantizado sólo si se respetan las prescripciones indicadas en el presente manual. La Empresa no se responsabiliza por los daños causados por el incumplimiento de las indicaciones dadas en el presente manual.
Dejando inalteradas las características esenciales del producto, la Empresa se reserva el derecho de realizar, en cualquier momento, modificaciones que considere convenientes para mejorar la técnica, la fabricación y la comercialización del producto, sin comprometerse a actualizar la presente publicación.
DEIMOS BT H QSC -
45
WAARSCHUWINGEN VOOR DE GEBRUIKER(NL)
LET OP! Belangrijke veiligheidsinstructies. De Waarschuwingen en de Instructies die met het product meegeleverd worden zorgvuldig lezen en volgen, aangezien verkeerd gebruik schade aan personen, dieren of voorwerpen kan veroorzaken. De instructies bewaren voor toekomstige raadpleging en doorgeven aan eventuele personen die het gebruik van de installatie overnemen.
Dit product is uitsluitend bestemd voor het gebruik waarvoor het uitdrukkelijk geïnstalleerd is. Ieder ander gebruik dient als oneigenlijk en dus gevaarlijk beschouwd te worden. De fabrikant mag niet verantwoordelijk worden gehouden voor eventuele schade veroorzaakt door oneigenlijk, verkeerd of onredelijk gebruik.
ALGEMENE VEILIGHEID
Wij danken u ervoor dat u de voorkeur hebt gegeven aan dit product. Wij als bedrijf zijn er zeker van dat dit product de voor uw gebruik noodzakelijke prestaties kan leveren.
Dit product voldoet aan de erkende normen van de techniek en van de bepalingen betreffende de veiligheid, indien correct geïnstalleerd door gekwalificeerd en ervaren personeel (professionele installateur).
Het automatiseringssysteem, indien juist geïnstalleerd en gebruikt, voldoet aan de vereiste veiligheidsgraad bij het gebruik. Het is niettemin nuttig enkele gedragsregels in acht te nemen om onopzettelijke ongemakken te vermijden:
- Kinderen, personen en voorwerpen buiten de actieradius van het automatiseringssysteem houden, met name tijdens de beweging.
- Niet aan kinderen toestaan om in de actieradius van het automatiseringssysteem te spelen of zich daarbinnen te bevinden.
- Dit automatiseringssysteem is niet bestemd om te worden gebruikt door kinderen of door personen waarvan de mentale, fysieke en sensorische capaciteiten beperkt zijn, of met gebrek aan kennis.
- Vermijden om te werken in de buurt van de scharnieren of bewegende mechanische onderdelen.
- De beweging van de vleugel niet tegengaan en niet proberen de deur handmatig te openen, als de actuator niet gedeblokkeerd is met de speciale deblokkeringsknop.
- Niet de actieradius van de gemotoriseerde deur of hek betreden tijdens de beweging daarvan.
- Afstandsbedieningen of andere besturingsinrichtingen buiten bereik van kinderen bewaren om ongewilde activeringen te vermijden.
- De activering van de handmatige deblokkering zou ongecontroleerde bewegingen van de deur kunnen veroorzaken, als dit gebeurt tijdens mechanische storingen of in onevenwichtige toestanden.
- In geval van afstandsbediening rolluiken: het bewegende rolluik controleren en de personen op een afstand houden tot deze niet volledig gesloten is. Opletten wanneer de deblokkering wordt geactiveerd, indien aanwezig, omdat een open rolluik snel zou kunnen vallen in aanwezigheid van slijtage of gebreken.
- Het stukgaan of de slijtage van mechanische onderdelen van de deur (geleide deel), zoals bijvoorbeeld kabels, veren, steunen, klepscharnieren, geleiders, kan gevaren veroorzaken. De installatie periodiek laten controleren door gekwalificeerd en ervaren personeel (professionele installateur) volgens hetgeen aangegeven door de installateur of de deurenfabrikant.
- Voor alle externe schoonmaakwerkzaamheden het voedingsnet loskoppelen.
- De optieken van de fotocellen en de signaleringsinrichtingen schoon houden.
Controleren of takken en struiken de veiligheidsinrichtingen niet storen.
- Het automatisme niet gebruiken, als daarop onderhoudswerkzaamheden nodig zijn. In geval van storing of defect van het automatiseringssysteem, het voedingsnet loskoppelen van het automatiseringssysteem, geen pogingen ondernemen tot reparatie of directe werkzaamheden en zich alleen tot gekwalificeerd en ervaren personeel wenden (professionele installateur) voor de noodzakelijke reparatie of onderhoud. Om de toegang mogelijk te maken, de nood-deblokkering activeren
(indien aanwezig).
- Voor wat voor directe werkzaamheden dan ook op het automatiseringssysteem of de installatie, die niet door deze handleiding voorzien zijn, gebruik maken van gekwalificeerd en ervaren personeel (professionele installateur).
- Minstens eenmaal per jaar de goede toestand en de correcte werking van het automatiseringssysteem laten controleren door gekwalificeerd en ervaren personeel (professionele installateur), met name van alle veiligheidsinrichtingen.
- De installatie-, onderhouds- en reparatiewerkzaamheden moeten gedocumenteerd worden en de desbetreffende documentatie moet ter beschikking worden gehouden van de gebruiker.
- Het niet naleven van hetgeen hierboven beschreven is, kan gevaarlijke situaties creëren.
Al hetgeen niet uitdrukkelijk voorzien is in deze gebruikershandleiding, is niet toegestaan. De goede werking van de controller is alleen gegarandeerd, als de voorschriften aanwezig in deze handleiding in acht worden genomen. Het bedrijf is niet gehouden zich te verantwoorden voor de schade veroorzaakt door het niet in acht nemen van de aanwijzingen vermeld in deze handleiding.
Terwijl de hoofdkenmerken van het product ongewijzigd blijven, behoudt het Bedrijf zich het recht voor om op ieder willekeurig moment die wijzigingen aan te brengen die zij geschikt acht om het product technisch, constructief en commercieel gezien te verbeteren, zonder deze publicatie te hoeven bijwerken.
46 -
DEIMOS BT H QSC
DEIMOS BT H QSC -
47
Download
Advertisement