G6D PCB Relay
PCB Relay
G6D
Slim, Miniature Relay, Capable of
Relaying Programmable Controller and
Temperature Controller Outputs
■
■
■
■
■
■
Slim and miniature: 17.5 × 6.5 × 12.5 mm
(L × W × H).
Ideal for high-density mounting.
Switches 5 A at 250 VAC/30 VDC.
Allows 300,000 operations with a 2-A load at
250 VAC or 30 VDC.
Actual load switching capability equals the G6B’s
capability.
Washable construction.
RCE
Ordering Information
Classification
Contact form
Standard
SPST-NO
Enclosure ratings
Fully sealed
Model
G6D-1A-ASI
Note: When ordering, add the rated coil voltage to the model number.
Example: G6D-1A-ASI 12 VDC
Rated coil voltage
Model Number Legend
G6D -
1
2
VDC
3
1. Number of Poles
1: 1 pole
2. Contact Form
A: SPST-NO
■
3. Contact Material
ASI: Silver alloy (cadmium-free)
4. Rated Coil Voltage
5, 12, 24 VDC
Accessories (Order Separately)
Connecting Socket
■
4
P6D-04P
Coil Ratings
Rated voltage
5 VDC
12 VDC
Rated current
40 mA
16.7 mA
8.3 mA
Coil resistance
125 Ω
720 Ω
2,880 Ω
Must operate voltage
70% max. of rated voltage
Must release voltage
10% min. of rated voltage
Max. voltage
160% of rated voltage (at 23°C)
Power consumption
Approx. 200 mW
Note:
24 VDC
The must operate voltage is 75% or less of the rated voltage if the relay is mounted upside down.
1
G6D
G6D
Contact Ratings
■
Rated load
5 A at 250 VAC, 5 A at 30 VDC, resistive load
Rated carry current
5A
Max. switching voltage
250 VAC, 30 VDC
Max. switching current
5A
Max. switching power
1,250 VA, 150 W
Failure rate (reference value)
10 mA at 5 VDC
Note:
P level: λ60 = 0.1 x 10–6/operation
Characteristics
■
Contact resistance
100 mΩ max.
Operate time
10 ms max.
Release time
5 ms max.
Insulation resistance
1,000 MΩ min. (at 500 VDC)
Dielectric strength
3,000 VAC, 50/60 Hz for 1 min between coil and contacts
750 VAC, 50/60 Hz for 1 min between contacts of same polarity
Impulse withstand voltage
6,000 V (1.2 x 50 µs) between coil and contacts
Vibration resistance
Destruction: 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude)
Malfunction: 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude)
Shock resistance
Destruction: 1,000 m/s2
Malfunction: 100 m/s2
Endurance
Mechanical: 20,000,000 operations min. (at 18,000 operations/hr)
Electrical:
70,000 operations min. (5 A at 250 VAC/30 VDC, resistive load)
300,000 operations min. (2 A at 250 VAC/30 VDC, resistive load)
Ambient temperature
Operating: −25°C to 70°C (with no icing)
Ambient humidity
Operating: 5% to 85%
Weight
Approx. 3 g
50
30
10
AC resistive load
5
3
DC resistive
load
1
AC inductive
load
cosφ=0.4
DC inductive
load
0.5
Endurance
Ambient Temperature vs.
Maximum Coil Voltage
Maximum coil voltage (%)
Switching current (A)
Maximum Switching Power
Endurance (x104 operations)
Engineering Data
500
300
100
250-VAC/30-VDC resistive load
50
30
10
160
140
120
(cosφ=0.4/ L/R=7 ms)
3
0.1
0
3
5
10
30
100
0
250 500 1,000
80
1
2
3
4
Ambient Temperature vs.
Operating/Recovery Voltage
G6D-1A-ASI
100
6
7
8
9
60
0
10
1,000
800
600
X
60
max.
400
X
min.
200
40
20
0
−40
Z
206
max.
X
min.
X'
Z'
Energized
−20
0
20
40
60
80
Ambient temperature (°C)
Shock direction
X
X'
Y
Not energized
Y'
Unit: m/s2
Z
Z'
Y'
Measurement conditions: Impose a shock in the
±X, ±Y, and ±Z directions three times each with
the Relay energized to check the shock values
that cause the Relay to malfunction.
40
50
60
70
80
90
Note: The maximum coil voltage is the
maximum voltage that can be
applied to the relay coil
Y
80
23 30
Ambient temperature (°C)
Malfunctioning Shock
G6D-1A-ASI
Operating voltage
Recovery voltage
Sample: G6D1A
Quantity: 5
5
Switching current (A)
Switching voltage (V)
Operating/recovery voltage (ratio of rated voltage) (%)
180
100
5 250-VAC/30 VDC inductive load
0.3
2
200
Coil terminals
G6D
■
G6D
Approved Standards
• The rated values approved by each of the safety standards may be different from the performance characteristics individually defined in
this catalog.
UL Approval
(File No. E41515) UL508
Model
G6D-1A-ASI
Number of poles
Coil ratings
1
Contact ratings
5 to 24 VDC
Number of test
operations
5 A, 250 VAC (General Use) 6,000
5 A, 30 VDC
CSA Approval
(File No. LR31928) C22.2 No. 14
Model
G6D-1A-ASI
Number of poles
Coil ratings
1
Contact ratings
5 to 24 VDC
Number of test
operations
5 A, 250 VAC (General Use) 6,000
5 A, 30 VDC (Resistive)
EN/TÜV Approval
Model
G6D-1A-ASI
(Registration No. R50029064/EN61810-1)
Number of poles
Coil ratings
1
Contact ratings
5, 12, 24 VDC
Number of test
operations
5 A, 250 VAC (cosφ=1.0)
70,000
5 A, 30 VDC (0 ms)
Dimensions
Note:
1. All units are in millimeters unless otherwise indicated.
2. Orientation marks are indicated as follows:
G6D-1A-ASI
Terminal Arrangement/
Internal Connections
(Bottom View)
6.5 max.
17.5 max.
(17.3)*
0.5
(6.4)*
Mounting Holes
(Bottom View)
Tolerance: ±0.1
12.5 max.
(12.4)*
(1.13) Four, 1.1-dia.
holes
2.54
(0.71)
3.5
0.5
2.54
0.8
7.62.
5.08
1
5
7
0.3
5.08
2.54
5.08
13
*Average value
P6D-04P Socket
15.24
19.7 max.
(19.5)*
Mounting Holes
(Bottom View)
Tolerance: ±0.1
6.9 max.
(6.7)*
Four, 1.1-dia.
(2.18) holes
2.54
(0.86)
10.8
6+0.1
3.6
5.08
2.54
0.65
2.54
0.3
76.2 5.08
15.24
*Average value
3
G6D
G6D
Precautions
More than two relays can be closely mounted right side up as
shown in the following illustration.
Socket Mounting Height
6.5 mm
18.5 mm max.
Current flow:
5 A max.
More than two relays can be closely mounted upside down as
shown in the following illustration.
7.62 mm in the
upside-down
direction
When mounting the relay, insert it into the socket as vertically as
possible so that the relay terminals contact securely with the contact pins on the socket.
The P6D is flux-resistive. Do not wash the P6D with water.
Dismount the relay from the socket before soldering the socket to
a PCB.
Current flow:
2 A max.
1.12 mm
Note:
The space between each relay required for heat radiation
may vary with operating conditions. Contact your OMRON
representative for details.
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
Cat. No. K127-E1-01A In the interest of product improvement, specifications are subject to change without notice.
OMRON RELAY & DEVICES Corporation
C&C Power Relay Division
Marketing Department
1110 Sugi, Yamaga-City,
Kumamoto, 861-0596 Japan
Tel: (81)968-44-4160/Fax: (81)968-44-4107
4
Printed in Japan
1208
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement