DIRIS® A

DIRIS® A
DIRIS A
Socomec worldwide
Measurement precision
The multi-function multi-measurement range
DIRIS 568 A
DIRIS products have a built-in
electronic component (ASIC)
developed specifically by
SOCOMEC for the measurement
function, which can achieve very
high measurement precision.
®
IN EUROPE
IN ASIA
BELGIUM
NORTH EAST ASIA
SOCOMEC BELGIE
B - 1190 Brussel
Tel. +32 (0)2 340 02 30 - Fax +32 (0)2 346 28 99
[email protected]
SOCOMEC CHINA
CN - 20030 P.R.C Shanghai
Tel. +86 21 5298 9555 - Fax +86 21 6228 3468
[email protected]
FRANCE
SOUTH EAST ASIA & PACIFIC
SOCOMEC
F - 67235 Benfeld Cedex
Tel. +33 (0)3 88 57 41 41 - Fax +33 (0)3 88 74 08 00
[email protected]
SOCOMEC SWITCHING AND PROTECTION
UBI TECHPARK - Singapore
Tel. +65 65 07 94 90 - Fax +65 65 47 86 93
[email protected]
GERMANY
SOUTH ASIA
SOCOMEC GmbH
D - 76275 Ettlingen
Tel. +49 (0)7243 65 29 2 0 - Fax +49 (0)7243 65 29 2 13
[email protected]
COUV 162 A / QUAT UPS 3
Thanks to the optional modules
which you can use to upgrade
the product functions at any time,
DIRIS A has optimum adaptability
to the requirements of multimeasurement applications.
SOCOMEC is once again expanding the field of application
of the DIRIS A, with the new modules for:
• Ethernet communication
• temperature measurement & monitoring.
DIRIS 767 A
Customised upgradeability
FOR MANAGING YOUR ELECTRICAL NETWORKS
MADE TO MEASURE
DIRIS ® system: the reference
Measurement is the key link in managing an energy efficiency
project.
With DIRIS, SOCOMEC has developed the most advanced
Power Measurement Device on the market, dedicated to
improving your energy performance.
For over 20 years, thousands of users, installers or integrators
have trusted the innovative DIRIS solutions for:
• energy metering and management
• electrical facility monitoring
• power quality analysis.
Follow the leader and run with the pioneers, by opting for
the DIRIS solution.
SOCOMEC-HPL PVT
Gurgaon, Haryana - India
Tel. +91 124 2210970 – 74 - Fax +91 124 2210976
[email protected]
Optimised connectivity
The new communication modules offer direct connectivity
to an Ethernet communication network, and the integrated
gateway function enabling Ethernet connection of a cluster
of products communicating via RS 485.
SOCOMEC Elettrotecnica s.r.l.
I - 20098 San Giuliano Milanese (MI)
Tel. +39 02 98 498 21 - Fax +39 02 98 243 310
[email protected]
IN MIDDLE EAST
SPAIN
UNITED ARAB EMIRATES
SOCOMEC ELECTRO, S.L.
E - 08310 Argentona (Barcelona)
Tel. +34 93 741 60 67 - Fax. +34 93 757 49 52
[email protected]
SOCOMEC Middle East
Dubai, U.A.E.
Tel. +971 4 88 11 623 - Fax +971 4 88 19 887
[email protected]
RS485 / Ethernet
gateway function
IN NORTH AMERICA
UNITED KINGDOM
USA, CANADA & MEXICO
SOCOMEC Ltd
Hitchin Hertfordshire SG4 0TY
Tel. +44 (0)1462 440033 - Fax +44 (0)1462 431143
[email protected]
SOCOMEC Inc
Cambridge, MA 02142 USA
Tel. +617 245 0447 - Fax +617 245 0437
[email protected]
Direct
Ethernet
connection
Expanded monitoring
Sensor PT 100-1
Sensor PT 100-2
Sensor PT 100Internal T°
measurement
Sensor PT 100-3
The embedded web server
The new Ethernet communication modules incorporate the
embedded web server function, thereby enabling remote
operation and configuration of a product without specific
software. Access is via your Internet browser, simply by
entering the IP address of the DIRIS.
DIRIS 747 A
HEAD OFFICE
SOCOMEC GROUP
S.A. SOCOMEC capital 11 302 300 
R.C.S. Strasbourg B 548 500 149
B.P. 60010 - 1, rue de Westhouse - F-67235 Benfeld Cedex - FRANCE
www.socomec.com
INTERNATIONAL
SALES DEPARTMENT
SOCOMEC
1, rue de Westhouse - B.P. 60010
F - 67235 Benfeld Cedex - FRANCE
Tel. +33 (0)3 88 57 41 41 - Fax +33 (0)3 88 74 08 00
[email protected]
A comprehensive range for
measuring your energy efficiency
The new DIRIS & COUNTIS solutions are tailored to
the requirements of industrial or tertiary environments:
energy metering, quality monitoring and analysis of electrical
networks.
analysis
+
monitoring
+
metering
ENERGY
EFFICIENCY
ENERGY
MANAGEMENT
ENERGY
MEASUREMENT
Compliant with the new IEC 61557-12 standard specifically
for multi-measurement devices (PMD), they guarantee the
operator a product designed and tested in accordance with
the functional requirements of its application, ensuring a high
performance level.
Non contractual document. © 2009, Socomec SA. All rights reserved.
VALID FOR FRANCE
For further information: www.socomec.com
DIRIS 781 A GB
DIRIS 749 A - DIRIS 742 A
RS485
SOCOMEC B.V.
NL - 3992 De Houten
Tel. +31 (0)30 63 71 504 - Fax +31 (0)30 63 72 166
[email protected]
Réf. DOC 51123 - 04/09 - Photo : Martin Bernhart - Réalisation : SOCOMEC Service Communication - Gyss Imprimeur Obernai
THE NETHERLANDS
Ethernet
The new temperature monitoring
module:
• enhances energy diagnostics
• improves monitoring of facilities
GAMME 115 A GB
ITALY
Measurement precision
Measurement is the key link in managing an energy efficiency
project.
DIRIS products have a built-in
electronic component (ASIC)
developed specifically by
SOCOMEC for the measurement
function, which can achieve very
high measurement precision.
With DIRIS, SOCOMEC has developed the most advanced
Power Measurement Device on the market, dedicated to
improving your energy performance.
For over 20 years, thousands of users, installers or integrators
have trusted the innovative DIRIS solutions for:
• energy metering and management
• electrical facility monitoring
• power quality analysis.
DIRIS 568 A
DIRIS ® system: the reference
Follow the leader and run with the pioneers, by opting for
the DIRIS solution.
GAMME 115 A GB
Thanks to the optional modules
which you can use to upgrade
the product functions at any time,
DIRIS A has optimum adaptability
to the requirements of multimeasurement applications.
SOCOMEC is once again expanding the field of application
of the DIRIS A, with the new modules for:
• Ethernet communication
• temperature measurement & monitoring.
DIRIS 767 A
Customised upgradeability
Optimised connectivity
The new communication modules offer direct connectivity
to an Ethernet communication network, and the integrated
gateway function enabling Ethernet connection of a cluster
of products communicating via RS 485.
Ethernet
A comprehensive range for
measuring your energy efficiency
The new DIRIS & COUNTIS solutions are tailored to
the requirements of industrial or tertiary environments:
energy metering, quality monitoring and analysis of electrical
networks.
+
metering
Direct
Ethernet
connection
ENERGY
EFFICIENCY
ENERGY
MANAGEMENT
ENERGY
MEASUREMENT
Compliant with the new IEC 61557-12 standard specifically
for multi-measurement devices (PMD), they guarantee the
operator a product designed and tested in accordance with
the functional requirements of its application, ensuring a high
performance level.
Expanded monitoring
The new temperature monitoring
module:
• enhances energy diagnostics
• improves monitoring of facilities
Sensor PT 100-1
Sensor PT 100-2
Sensor PT 100Internal T°
measurement
Sensor PT 100-3
The embedded web server
For further information: www.socomec.com
The new Ethernet communication modules incorporate the
embedded web server function, thereby enabling remote
operation and configuration of a product without specific
software. Access is via your Internet browser, simply by
entering the IP address of the DIRIS.
DIRIS 747 A
+
monitoring
RS485 / Ethernet
gateway function
DIRIS 781 A GB
analysis
DIRIS 749 A - DIRIS 742 A
RS485
DIRIS A20 and A40
®
Dedicated supervision
For remote monitoring and supervision of DIRIS A, the
CONTROL VISION software enables you to:
•
•
•
•
•
•
•
TYPE OF MEASUREMENT
Application network (3 P, 3 P+N and single-phase)
Real effective up to harmonic
MEASUREMENT PRECISION
Current and voltage
Application
Frequency
Active energy
Reactive energy
REFRESH PERIOD
Display
CURRENT INPUTS
Current transformer primary
Current transformer secondary
CT secondary earthed
VOLTAGE INPUTS
Direct measurement
Measurement from PT (secondary 60, 100, 110, 115, 120,
DIRIS A40 / A41
•
A41
•
•
•
•
•
•
•
The new DIRIS A Power Measurement Devices with extended
functionality enabling you to:
• reduce operating costs,
• reduce production costs,
• optimise maintenance costs,
• improve the efficiency of the facility.
•
•
DIRIS A20
DIRIS A40 / A41
LV
51
LV / HV
63
0.2%
0.5%
0.1%
Class 0.5S IEC 62053-22
Class 2 IEC 62053-23
5A
50 to 500 V AC
50 to 700 V AC
n/a
up to 500 kV AC
45 to 65 Hz
Other
DIRIS 742 A - DIRIS 743 A
DIRIS A40 / A41
References
> DIRIS A20
DIRIS A20 supply 110 to 400 V AC and 120 to 350 V DC
Module 1 output
JBUS/MODBUS communication module
4825 0200
4825 0080
4825 0082
DIRIS A40 supply 110 to 400 V AC and 120 to 350 V DC
DIRIS A40 supply 12 to 48 V DC
DIRIS A41 supply 110 to 400 V AC and 120 to 350 V DC
DIRIS A41 supply 12 to 48 V DC
Pulse outputs module
JBUS/MODBUS communication module
PROFIBUS-DP communication module
Ethernet Module
Ethernet module with RS485 gateway
Temperature module
Analogue outputs module
Monitoring or control/command module
Memory module
ACCESSORY
IP65 protection
4825 0201
4825 1201
4825 0202
4825 1202
4825 0090
4825 0092
4825 0205
4825 0203
4825 0204
4825 0206
4825 0093
4825 0094
4825 0097
PULSE OUTPUTS
DIRIS 445 A
DIRIS 447 A
DIRIS 775 A
DIRIS 777 A
DIRIS 776 A
COMMUNICATION
• RS485 connection with JBUS/MODBUS protocol (speed up to 38,400 bauds): 1 module
•
•
• RS485 connection with PROFIBUS DP protocol (speed up to 12 Mbauds): 1 module
•
• Ethernet connection with Modbus RTU or JBUS/MODBUS RTU over TCP protocol
•
• Ethernet connection with RS485 gateway with Modbus RTU or JBUS/MODBUS RTU over TCP protocol
•
DIRIS 448 A
• 2 outputs configurable to all values measured by DIRIS
Maximum of 2 modules can be connected, i.e. 4 analogue outputs
•
DIRIS 449 A
• 2 to 6 outputs allocated to monitoring of 3I, In, 3V, 3U, F, ±∑P, ±∑Q, ∑S, ∑PFL/C,
to all values measured by DIRIS or to remote control
• 2 to 6 inputs for pulse counting
Measuring
Monitoring
Analysing
Communicating
energy consumed by
each building or process,
in order to allocate and
optimise energy costs
(multi-fluid management)
all electrical or analogue
values (temperature, etc.)
to verify that your facilities
are functioning properly
your electrical networks
via alarm management,
secure monitoring of
distribution parameters
and remote control of
electrical equipment
energy quality via detailed
breakdown of harmonics
and identification of
troughs, outages and
voltage surges on the
electrical network
all available information
via a network tailored to
your facility:
> ETHERNET (Modbus
TCP, Jbus/Modbus RTU
over TCP)
> RS485 (Jbus/Modbus,
Profibus DP)
DIRIS 682 A
• Memorisation of P+, P-, Q+, Q- with an internal or external synchronisation signal
of 5, 8 ,10, 15, 20 and 30 minutes for 31 or 62 days
• Memorisation of the last 10 time-stamped alarms
• Memorisation of minimum and maximum instant values
for 3U, 3V, 3I, In, F, ±∑P, ±∑Q, ∑S, THD3U, THD3V, THD3I, THDIn
• Time-stamped memorisation of the last 10 voltage troughs, voltage surges,
outages (EN 50160)
• Memorisation of average values according to the synchronisation signal for 3U, 3V and F
Primary
wound CT
W
• Internal temperature indication
• Temperature indication via external sensor (T°1)
• Temperature indication via external sensor (T°2)
• Temperature indication via external sensor (T°3)
H
•
•
•
W
W
H
H
D
W
Hd
W
W
H
D
W
H
D
W
W
•
•
•
•
TRB 70
D
•
•
TEMPERATURE INPUTS (SENSOR PT100)
Memorisation of all
electrical values on DIRIS
units defined as "constant
scanning" in a table
(displayed according to a
chosen period) stored on
the database.
Display in table form of all
electrical values of every
DIRIS present on the
network.
4825 0089
Associated current transformers
•
•
MEMORY
DIRIS 747 A
DIRIS 774 A
2 INPUTS - 2 OUTPUTS
Metering
H
d
H
H (mm)
W
W (mm)
H
D (mm)
D
cable d (mm)
bar x 1 (mm)
bar x 2 (mm)
d
bar x 3 (mm)
88.5
71
45
Through
cable CT
TCA
21
65
45
30
21
TCA
13-3P
90
105
65.2
13.5
Through-bar or through-cable CT
TCB
TCB
TCB
17-20 28-30 32-40
65
70
88.5
49.5
49.9
71
50
68
58
17.5
28
32
20x5 30x10 40x10
TCB
44-50
101.5
86
58
44
50x12
40x10
TCB
44-63
108.5
96
58
44
63x10
40x10
TCB
85-100
187.5
172
52
85
100x10
80x10
Through-bar CT
TCB
TBA
TBA
TBA 60 TBA 100
T0 23
100-125
103
127
187.5
132
170
150
175
106
172
88
129
99
100
93
52
78
78
55
55
58
100
31
55.5
41
38
20
60x30 100x30 100x35 128x38 20x30
120x10
Split-core CT
TO 58
TO 812
TO 816
152
125
58
50
50x80
198
155
58
80
80x120
246
195
79
80
80x160
d
H
d
APPLI 386 A
DIRIS 773 A
SUB D9
•
•
ANALOGUE OUTPUTS
DIRIS A41
> DIRIS A40 / A41
1 OUTPUT ALLOCATED TO
• Pulses: configurable (type, weight, time) in kWh or kvarh
• Monitoring: 3I, In, 3V, 3U, F, ∑P, ∑Q, SS, ∑PFL/C, THD 3I, THD 3V, THD 3U and timer
DIRIS A20/A40
•
• 2 configurable pulse outputs (type, weight and duration)
Table or bar graph display
of 3rd to 25th harmonics.
DIRIS 513 A
For your specific requirements, additional functions may be
added via plug-in modules (maximum 4 for DIRIS A40 and 3 for
DIRIS A41).
Energy consumption table
(electricity, water, gas…) or
pulses counted by all the
DIRIS.
110 to 400 V AC ±10%
120 to 350 V DC ±20%
12 to 48 V DC -6/+20 %
n/a
Standard
DIRIS A20
5 to 10,000 A
5 A and 1 A
Yes
Frequency
AUXILIARY POWER SUPPLY
Optional functions
Display of all electrical
quantities in the form
of numeric values or
indicators.
1 second
173 and 190 V)
•
• centralise and display all electrical values,
• create load curves,
• perform measurement campaigns,
• manage alarm history.
DIRIS 507 A
DIRIS 742 A
•
Spectral analysis of individual current and voltage harmonics up to the 63rd harmonic (HI, HU, HV)
METERS
Active and reactive energy on 4 quadrants (± kWh, ± kvarh)
Active, reactive and apparent energy on 4 quadrants (±kWh, ±kvarh, kVAh)
Characteristics
The universal multi-function solution
DIRIS A20
INSTANTANEOUS, RMS VALUES
Current (3I, In)
4th CT for measuring neutral current (In) on networks with harmonic disturbances
Phase-neutral and phase-phase voltage (3V, 3U)
Frequency (F)
Active, reactive and apparent power, per phase and total (±3P, ±3Q, 3S, ±∑P, ±∑Q, ∑S)
Power factor, per phase and total (3PF L/C, ∑PF L/C)
AVERAGE AND MAXIMUM VALUE MEASUREMENTS
Current (3I, In)
Phase-neutral & phase-phase voltages and frequency (3U, 3V, F)
Total active, reactive and apparent power (±∑P, ±∑Q, ∑S)
POWER QUALITY MEASUREMENTS
Harmonic distortion rate on current and voltage integrated up to the 51st harmonic (THD 3I, 3V, 3U)
Harmonic distortion rate on current and voltage integrated up to the 63rd harmonic (THD 3I, 3V, 3U)
MEASURE
DIRIS 508 A
The following functions are standard on DIRIS A products:
TO
DIRIS 512 A
MADE
Standard functions
Specification and software
DIRIS 511 A
Upgradeable intelligence
Primary (A) 5 ... 40
Secondary (A)
5
5 ...
300
5
50 ... 160
5
60 ...
400
5
50 ...
600
5
50 ...
1000
5
100 ...
1250
5
200 ...
1500
5
750 ...
3000
5
1000 ...
4000
5
200 ... 600 ...
2000 4000
5
5
400 ... 400 ... 100 ... 250 ...
2000 4000 400
1000
5
5
5
5
250 ...
1500
5
1000 ...
5000
5
DIRIS A20 and A40
®
Dedicated supervision
For remote monitoring and supervision of DIRIS A, the
CONTROL VISION software enables you to:
•
•
•
•
•
•
•
TYPE OF MEASUREMENT
Application network (3 P, 3 P+N and single-phase)
Real effective up to harmonic
MEASUREMENT PRECISION
Current and voltage
Application
Frequency
Active energy
Reactive energy
REFRESH PERIOD
Display
CURRENT INPUTS
Current transformer primary
Current transformer secondary
CT secondary earthed
VOLTAGE INPUTS
Direct measurement
Measurement from PT (secondary 60, 100, 110, 115, 120,
DIRIS A40 / A41
•
A41
•
•
•
•
•
•
•
The new DIRIS A Power Measurement Devices with extended
functionality enabling you to:
• reduce operating costs,
• reduce production costs,
• optimise maintenance costs,
• improve the efficiency of the facility.
•
•
DIRIS A20
DIRIS A40 / A41
LV
51
LV / HV
63
0.2%
0.5%
0.1%
Class 0.5S IEC 62053-22
Class 2 IEC 62053-23
5A
50 to 500 V AC
50 to 700 V AC
n/a
up to 500 kV AC
45 to 65 Hz
Other
DIRIS 742 A - DIRIS 743 A
DIRIS A40 / A41
References
> DIRIS A20
DIRIS A20 supply 110 to 400 V AC and 120 to 350 V DC
Module 1 output
JBUS/MODBUS communication module
4825 0200
4825 0080
4825 0082
DIRIS A40 supply 110 to 400 V AC and 120 to 350 V DC
DIRIS A40 supply 12 to 48 V DC
DIRIS A41 supply 110 to 400 V AC and 120 to 350 V DC
DIRIS A41 supply 12 to 48 V DC
Pulse outputs module
JBUS/MODBUS communication module
PROFIBUS-DP communication module
Ethernet Module
Ethernet module with RS485 gateway
Temperature module
Analogue outputs module
Monitoring or control/command module
Memory module
ACCESSORY
IP65 protection
4825 0201
4825 1201
4825 0202
4825 1202
4825 0090
4825 0092
4825 0205
4825 0203
4825 0204
4825 0206
4825 0093
4825 0094
4825 0097
PULSE OUTPUTS
DIRIS 445 A
DIRIS 447 A
DIRIS 775 A
DIRIS 777 A
DIRIS 776 A
COMMUNICATION
• RS485 connection with JBUS/MODBUS protocol (speed up to 38,400 bauds): 1 module
•
•
• RS485 connection with PROFIBUS DP protocol (speed up to 12 Mbauds): 1 module
•
• Ethernet connection with Modbus RTU or JBUS/MODBUS RTU over TCP protocol
•
• Ethernet connection with RS485 gateway with Modbus RTU or JBUS/MODBUS RTU over TCP protocol
•
DIRIS 448 A
• 2 outputs configurable to all values measured by DIRIS
Maximum of 2 modules can be connected, i.e. 4 analogue outputs
•
DIRIS 449 A
• 2 to 6 outputs allocated to monitoring of 3I, In, 3V, 3U, F, ±∑P, ±∑Q, ∑S, ∑PFL/C,
to all values measured by DIRIS or to remote control
• 2 to 6 inputs for pulse counting
Measuring
Monitoring
Analysing
Communicating
energy consumed by
each building or process,
in order to allocate and
optimise energy costs
(multi-fluid management)
all electrical or analogue
values (temperature, etc.)
to verify that your facilities
are functioning properly
your electrical networks
via alarm management,
secure monitoring of
distribution parameters
and remote control of
electrical equipment
energy quality via detailed
breakdown of harmonics
and identification of
troughs, outages and
voltage surges on the
electrical network
all available information
via a network tailored to
your facility:
> ETHERNET (Modbus
TCP, Jbus/Modbus RTU
over TCP)
> RS485 (Jbus/Modbus,
Profibus DP)
DIRIS 682 A
• Memorisation of P+, P-, Q+, Q- with an internal or external synchronisation signal
of 5, 8 ,10, 15, 20 and 30 minutes for 31 or 62 days
• Memorisation of the last 10 time-stamped alarms
• Memorisation of minimum and maximum instant values
for 3U, 3V, 3I, In, F, ±∑P, ±∑Q, ∑S, THD3U, THD3V, THD3I, THDIn
• Time-stamped memorisation of the last 10 voltage troughs, voltage surges,
outages (EN 50160)
• Memorisation of average values according to the synchronisation signal for 3U, 3V and F
Primary
wound CT
W
• Internal temperature indication
• Temperature indication via external sensor (T°1)
• Temperature indication via external sensor (T°2)
• Temperature indication via external sensor (T°3)
H
•
•
•
W
W
H
H
D
W
Hd
W
W
H
D
W
H
D
W
W
•
•
•
•
TRB 70
D
•
•
TEMPERATURE INPUTS (SENSOR PT100)
Memorisation of all
electrical values on DIRIS
units defined as "constant
scanning" in a table
(displayed according to a
chosen period) stored on
the database.
Display in table form of all
electrical values of every
DIRIS present on the
network.
4825 0089
Associated current transformers
•
•
MEMORY
DIRIS 747 A
DIRIS 774 A
2 INPUTS - 2 OUTPUTS
Metering
H
d
H
H (mm)
W
W (mm)
H
D (mm)
D
cable d (mm)
bar x 1 (mm)
bar x 2 (mm)
d
bar x 3 (mm)
88.5
71
45
Through
cable CT
TCA
21
65
45
30
21
TCA
13-3P
90
105
65.2
13.5
Through-bar or through-cable CT
TCB
TCB
TCB
17-20 28-30 32-40
65
70
88.5
49.5
49.9
71
50
68
58
17.5
28
32
20x5 30x10 40x10
TCB
44-50
101.5
86
58
44
50x12
40x10
TCB
44-63
108.5
96
58
44
63x10
40x10
TCB
85-100
187.5
172
52
85
100x10
80x10
Through-bar CT
TCB
TBA
TBA
TBA 60 TBA 100
T0 23
100-125
103
127
187.5
132
170
150
175
106
172
88
129
99
100
93
52
78
78
55
55
58
100
31
55.5
41
38
20
60x30 100x30 100x35 128x38 20x30
120x10
Split-core CT
TO 58
TO 812
TO 816
152
125
58
50
50x80
198
155
58
80
80x120
246
195
79
80
80x160
d
H
d
APPLI 386 A
DIRIS 773 A
SUB D9
•
•
ANALOGUE OUTPUTS
DIRIS A41
> DIRIS A40 / A41
1 OUTPUT ALLOCATED TO
• Pulses: configurable (type, weight, time) in kWh or kvarh
• Monitoring: 3I, In, 3V, 3U, F, ∑P, ∑Q, SS, ∑PFL/C, THD 3I, THD 3V, THD 3U and timer
DIRIS A20/A40
•
• 2 configurable pulse outputs (type, weight and duration)
Table or bar graph display
of 3rd to 25th harmonics.
DIRIS 513 A
For your specific requirements, additional functions may be
added via plug-in modules (maximum 4 for DIRIS A40 and 3 for
DIRIS A41).
Energy consumption table
(electricity, water, gas…) or
pulses counted by all the
DIRIS.
110 to 400 V AC ±10%
120 to 350 V DC ±20%
12 to 48 V DC -6/+20 %
n/a
Standard
DIRIS A20
5 to 10,000 A
5 A and 1 A
Yes
Frequency
AUXILIARY POWER SUPPLY
Optional functions
Display of all electrical
quantities in the form
of numeric values or
indicators.
1 second
173 and 190 V)
•
• centralise and display all electrical values,
• create load curves,
• perform measurement campaigns,
• manage alarm history.
DIRIS 507 A
DIRIS 742 A
•
Spectral analysis of individual current and voltage harmonics up to the 63rd harmonic (HI, HU, HV)
METERS
Active and reactive energy on 4 quadrants (± kWh, ± kvarh)
Active, reactive and apparent energy on 4 quadrants (±kWh, ±kvarh, kVAh)
Characteristics
The universal multi-function solution
DIRIS A20
INSTANTANEOUS, RMS VALUES
Current (3I, In)
4th CT for measuring neutral current (In) on networks with harmonic disturbances
Phase-neutral and phase-phase voltage (3V, 3U)
Frequency (F)
Active, reactive and apparent power, per phase and total (±3P, ±3Q, 3S, ±∑P, ±∑Q, ∑S)
Power factor, per phase and total (3PF L/C, ∑PF L/C)
AVERAGE AND MAXIMUM VALUE MEASUREMENTS
Current (3I, In)
Phase-neutral & phase-phase voltages and frequency (3U, 3V, F)
Total active, reactive and apparent power (±∑P, ±∑Q, ∑S)
POWER QUALITY MEASUREMENTS
Harmonic distortion rate on current and voltage integrated up to the 51st harmonic (THD 3I, 3V, 3U)
Harmonic distortion rate on current and voltage integrated up to the 63rd harmonic (THD 3I, 3V, 3U)
MEASURE
DIRIS 508 A
The following functions are standard on DIRIS A products:
TO
DIRIS 512 A
MADE
Standard functions
Specification and software
DIRIS 511 A
Upgradeable intelligence
Primary (A) 5 ... 40
Secondary (A)
5
5 ...
300
5
50 ... 160
5
60 ...
400
5
50 ...
600
5
50 ...
1000
5
100 ...
1250
5
200 ...
1500
5
750 ...
3000
5
1000 ...
4000
5
200 ... 600 ...
2000 4000
5
5
400 ... 400 ... 100 ... 250 ...
2000 4000 400
1000
5
5
5
5
250 ...
1500
5
1000 ...
5000
5
DIRIS A20 and A40
®
Dedicated supervision
For remote monitoring and supervision of DIRIS A, the
CONTROL VISION software enables you to:
•
•
•
•
•
•
•
TYPE OF MEASUREMENT
Application network (3 P, 3 P+N and single-phase)
Real effective up to harmonic
MEASUREMENT PRECISION
Current and voltage
Application
Frequency
Active energy
Reactive energy
REFRESH PERIOD
Display
CURRENT INPUTS
Current transformer primary
Current transformer secondary
CT secondary earthed
VOLTAGE INPUTS
Direct measurement
Measurement from PT (secondary 60, 100, 110, 115, 120,
DIRIS A40 / A41
•
A41
•
•
•
•
•
•
•
The new DIRIS A Power Measurement Devices with extended
functionality enabling you to:
• reduce operating costs,
• reduce production costs,
• optimise maintenance costs,
• improve the efficiency of the facility.
•
•
DIRIS A20
DIRIS A40 / A41
LV
51
LV / HV
63
0.2%
0.5%
0.1%
Class 0.5S IEC 62053-22
Class 2 IEC 62053-23
5A
50 to 500 V AC
50 to 700 V AC
n/a
up to 500 kV AC
45 to 65 Hz
Other
DIRIS 742 A - DIRIS 743 A
DIRIS A40 / A41
References
> DIRIS A20
DIRIS A20 supply 110 to 400 V AC and 120 to 350 V DC
Module 1 output
JBUS/MODBUS communication module
4825 0200
4825 0080
4825 0082
DIRIS A40 supply 110 to 400 V AC and 120 to 350 V DC
DIRIS A40 supply 12 to 48 V DC
DIRIS A41 supply 110 to 400 V AC and 120 to 350 V DC
DIRIS A41 supply 12 to 48 V DC
Pulse outputs module
JBUS/MODBUS communication module
PROFIBUS-DP communication module
Ethernet Module
Ethernet module with RS485 gateway
Temperature module
Analogue outputs module
Monitoring or control/command module
Memory module
ACCESSORY
IP65 protection
4825 0201
4825 1201
4825 0202
4825 1202
4825 0090
4825 0092
4825 0205
4825 0203
4825 0204
4825 0206
4825 0093
4825 0094
4825 0097
PULSE OUTPUTS
DIRIS 445 A
DIRIS 447 A
DIRIS 775 A
DIRIS 777 A
DIRIS 776 A
COMMUNICATION
• RS485 connection with JBUS/MODBUS protocol (speed up to 38,400 bauds): 1 module
•
•
• RS485 connection with PROFIBUS DP protocol (speed up to 12 Mbauds): 1 module
•
• Ethernet connection with Modbus RTU or JBUS/MODBUS RTU over TCP protocol
•
• Ethernet connection with RS485 gateway with Modbus RTU or JBUS/MODBUS RTU over TCP protocol
•
DIRIS 448 A
• 2 outputs configurable to all values measured by DIRIS
Maximum of 2 modules can be connected, i.e. 4 analogue outputs
•
DIRIS 449 A
• 2 to 6 outputs allocated to monitoring of 3I, In, 3V, 3U, F, ±∑P, ±∑Q, ∑S, ∑PFL/C,
to all values measured by DIRIS or to remote control
• 2 to 6 inputs for pulse counting
Measuring
Monitoring
Analysing
Communicating
energy consumed by
each building or process,
in order to allocate and
optimise energy costs
(multi-fluid management)
all electrical or analogue
values (temperature, etc.)
to verify that your facilities
are functioning properly
your electrical networks
via alarm management,
secure monitoring of
distribution parameters
and remote control of
electrical equipment
energy quality via detailed
breakdown of harmonics
and identification of
troughs, outages and
voltage surges on the
electrical network
all available information
via a network tailored to
your facility:
> ETHERNET (Modbus
TCP, Jbus/Modbus RTU
over TCP)
> RS485 (Jbus/Modbus,
Profibus DP)
DIRIS 682 A
• Memorisation of P+, P-, Q+, Q- with an internal or external synchronisation signal
of 5, 8 ,10, 15, 20 and 30 minutes for 31 or 62 days
• Memorisation of the last 10 time-stamped alarms
• Memorisation of minimum and maximum instant values
for 3U, 3V, 3I, In, F, ±∑P, ±∑Q, ∑S, THD3U, THD3V, THD3I, THDIn
• Time-stamped memorisation of the last 10 voltage troughs, voltage surges,
outages (EN 50160)
• Memorisation of average values according to the synchronisation signal for 3U, 3V and F
Primary
wound CT
W
• Internal temperature indication
• Temperature indication via external sensor (T°1)
• Temperature indication via external sensor (T°2)
• Temperature indication via external sensor (T°3)
H
•
•
•
W
W
H
H
D
W
Hd
W
W
H
D
W
H
D
W
W
•
•
•
•
TRB 70
D
•
•
TEMPERATURE INPUTS (SENSOR PT100)
Memorisation of all
electrical values on DIRIS
units defined as "constant
scanning" in a table
(displayed according to a
chosen period) stored on
the database.
Display in table form of all
electrical values of every
DIRIS present on the
network.
4825 0089
Associated current transformers
•
•
MEMORY
DIRIS 747 A
DIRIS 774 A
2 INPUTS - 2 OUTPUTS
Metering
H
d
H
H (mm)
W
W (mm)
H
D (mm)
D
cable d (mm)
bar x 1 (mm)
bar x 2 (mm)
d
bar x 3 (mm)
88.5
71
45
Through
cable CT
TCA
21
65
45
30
21
TCA
13-3P
90
105
65.2
13.5
Through-bar or through-cable CT
TCB
TCB
TCB
17-20 28-30 32-40
65
70
88.5
49.5
49.9
71
50
68
58
17.5
28
32
20x5 30x10 40x10
TCB
44-50
101.5
86
58
44
50x12
40x10
TCB
44-63
108.5
96
58
44
63x10
40x10
TCB
85-100
187.5
172
52
85
100x10
80x10
Through-bar CT
TCB
TBA
TBA
TBA 60 TBA 100
T0 23
100-125
103
127
187.5
132
170
150
175
106
172
88
129
99
100
93
52
78
78
55
55
58
100
31
55.5
41
38
20
60x30 100x30 100x35 128x38 20x30
120x10
Split-core CT
TO 58
TO 812
TO 816
152
125
58
50
50x80
198
155
58
80
80x120
246
195
79
80
80x160
d
H
d
APPLI 386 A
DIRIS 773 A
SUB D9
•
•
ANALOGUE OUTPUTS
DIRIS A41
> DIRIS A40 / A41
1 OUTPUT ALLOCATED TO
• Pulses: configurable (type, weight, time) in kWh or kvarh
• Monitoring: 3I, In, 3V, 3U, F, ∑P, ∑Q, SS, ∑PFL/C, THD 3I, THD 3V, THD 3U and timer
DIRIS A20/A40
•
• 2 configurable pulse outputs (type, weight and duration)
Table or bar graph display
of 3rd to 25th harmonics.
DIRIS 513 A
For your specific requirements, additional functions may be
added via plug-in modules (maximum 4 for DIRIS A40 and 3 for
DIRIS A41).
Energy consumption table
(electricity, water, gas…) or
pulses counted by all the
DIRIS.
110 to 400 V AC ±10%
120 to 350 V DC ±20%
12 to 48 V DC -6/+20 %
n/a
Standard
DIRIS A20
5 to 10,000 A
5 A and 1 A
Yes
Frequency
AUXILIARY POWER SUPPLY
Optional functions
Display of all electrical
quantities in the form
of numeric values or
indicators.
1 second
173 and 190 V)
•
• centralise and display all electrical values,
• create load curves,
• perform measurement campaigns,
• manage alarm history.
DIRIS 507 A
DIRIS 742 A
•
Spectral analysis of individual current and voltage harmonics up to the 63rd harmonic (HI, HU, HV)
METERS
Active and reactive energy on 4 quadrants (± kWh, ± kvarh)
Active, reactive and apparent energy on 4 quadrants (±kWh, ±kvarh, kVAh)
Characteristics
The universal multi-function solution
DIRIS A20
INSTANTANEOUS, RMS VALUES
Current (3I, In)
4th CT for measuring neutral current (In) on networks with harmonic disturbances
Phase-neutral and phase-phase voltage (3V, 3U)
Frequency (F)
Active, reactive and apparent power, per phase and total (±3P, ±3Q, 3S, ±∑P, ±∑Q, ∑S)
Power factor, per phase and total (3PF L/C, ∑PF L/C)
AVERAGE AND MAXIMUM VALUE MEASUREMENTS
Current (3I, In)
Phase-neutral & phase-phase voltages and frequency (3U, 3V, F)
Total active, reactive and apparent power (±∑P, ±∑Q, ∑S)
POWER QUALITY MEASUREMENTS
Harmonic distortion rate on current and voltage integrated up to the 51st harmonic (THD 3I, 3V, 3U)
Harmonic distortion rate on current and voltage integrated up to the 63rd harmonic (THD 3I, 3V, 3U)
MEASURE
DIRIS 508 A
The following functions are standard on DIRIS A products:
TO
DIRIS 512 A
MADE
Standard functions
Specification and software
DIRIS 511 A
Upgradeable intelligence
Primary (A) 5 ... 40
Secondary (A)
5
5 ...
300
5
50 ... 160
5
60 ...
400
5
50 ...
600
5
50 ...
1000
5
100 ...
1250
5
200 ...
1500
5
750 ...
3000
5
1000 ...
4000
5
200 ... 600 ...
2000 4000
5
5
400 ... 400 ... 100 ... 250 ...
2000 4000 400
1000
5
5
5
5
250 ...
1500
5
1000 ...
5000
5
DIRIS A
Socomec worldwide
Measurement precision
The multi-function multi-measurement range
DIRIS 568 A
DIRIS products have a built-in
electronic component (ASIC)
developed specifically by
SOCOMEC for the measurement
function, which can achieve very
high measurement precision.
®
IN EUROPE
IN ASIA
BELGIUM
NORTH EAST ASIA
SOCOMEC BELGIE
B - 1190 Brussel
Tel. +32 (0)2 340 02 30 - Fax +32 (0)2 346 28 99
[email protected]
SOCOMEC CHINA
CN - 20030 P.R.C Shanghai
Tel. +86 21 5298 9555 - Fax +86 21 6228 3468
[email protected]
FRANCE
SOUTH EAST ASIA & PACIFIC
SOCOMEC
F - 67235 Benfeld Cedex
Tel. +33 (0)3 88 57 41 41 - Fax +33 (0)3 88 74 08 00
[email protected]
SOCOMEC SWITCHING AND PROTECTION
UBI TECHPARK - Singapore
Tel. +65 65 07 94 90 - Fax +65 65 47 86 93
[email protected]
GERMANY
SOUTH ASIA
SOCOMEC GmbH
D - 76275 Ettlingen
Tel. +49 (0)7243 65 29 2 0 - Fax +49 (0)7243 65 29 2 13
[email protected]
COUV 162 A / QUAT UPS 3
Thanks to the optional modules
which you can use to upgrade
the product functions at any time,
DIRIS A has optimum adaptability
to the requirements of multimeasurement applications.
SOCOMEC is once again expanding the field of application
of the DIRIS A, with the new modules for:
• Ethernet communication
• temperature measurement & monitoring.
DIRIS 767 A
Customised upgradeability
FOR MANAGING YOUR ELECTRICAL NETWORKS
MADE TO MEASURE
DIRIS ® system: the reference
Measurement is the key link in managing an energy efficiency
project.
With DIRIS, SOCOMEC has developed the most advanced
Power Measurement Device on the market, dedicated to
improving your energy performance.
For over 20 years, thousands of users, installers or integrators
have trusted the innovative DIRIS solutions for:
• energy metering and management
• electrical facility monitoring
• power quality analysis.
Follow the leader and run with the pioneers, by opting for
the DIRIS solution.
SOCOMEC-HPL PVT
Gurgaon, Haryana - India
Tel. +91 124 2210970 – 74 - Fax +91 124 2210976
[email protected]
Optimised connectivity
The new communication modules offer direct connectivity
to an Ethernet communication network, and the integrated
gateway function enabling Ethernet connection of a cluster
of products communicating via RS 485.
SOCOMEC Elettrotecnica s.r.l.
I - 20098 San Giuliano Milanese (MI)
Tel. +39 02 98 498 21 - Fax +39 02 98 243 310
[email protected]
IN MIDDLE EAST
SPAIN
UNITED ARAB EMIRATES
SOCOMEC ELECTRO, S.L.
E - 08310 Argentona (Barcelona)
Tel. +34 93 741 60 67 - Fax. +34 93 757 49 52
[email protected]
SOCOMEC Middle East
Dubai, U.A.E.
Tel. +971 4 88 11 623 - Fax +971 4 88 19 887
[email protected]
RS485 / Ethernet
gateway function
IN NORTH AMERICA
UNITED KINGDOM
USA, CANADA & MEXICO
SOCOMEC Ltd
Hitchin Hertfordshire SG4 0TY
Tel. +44 (0)1462 440033 - Fax +44 (0)1462 431143
[email protected]
SOCOMEC Inc
Cambridge, MA 02142 USA
Tel. +617 245 0447 - Fax +617 245 0437
[email protected]
Direct
Ethernet
connection
Expanded monitoring
Sensor PT 100-1
Sensor PT 100-2
Sensor PT 100Internal T°
measurement
Sensor PT 100-3
The embedded web server
The new Ethernet communication modules incorporate the
embedded web server function, thereby enabling remote
operation and configuration of a product without specific
software. Access is via your Internet browser, simply by
entering the IP address of the DIRIS.
DIRIS 747 A
HEAD OFFICE
SOCOMEC GROUP
S.A. SOCOMEC capital 11 302 300 
R.C.S. Strasbourg B 548 500 149
B.P. 60010 - 1, rue de Westhouse - F-67235 Benfeld Cedex - FRANCE
www.socomec.com
INTERNATIONAL
SALES DEPARTMENT
SOCOMEC
1, rue de Westhouse - B.P. 60010
F - 67235 Benfeld Cedex - FRANCE
Tel. +33 (0)3 88 57 41 41 - Fax +33 (0)3 88 74 08 00
[email protected]
A comprehensive range for
measuring your energy efficiency
The new DIRIS & COUNTIS solutions are tailored to
the requirements of industrial or tertiary environments:
energy metering, quality monitoring and analysis of electrical
networks.
analysis
+
monitoring
+
metering
ENERGY
EFFICIENCY
ENERGY
MANAGEMENT
ENERGY
MEASUREMENT
Compliant with the new IEC 61557-12 standard specifically
for multi-measurement devices (PMD), they guarantee the
operator a product designed and tested in accordance with
the functional requirements of its application, ensuring a high
performance level.
Non contractual document. © 2009, Socomec SA. All rights reserved.
VALID FOR FRANCE
For further information: www.socomec.com
DIRIS 781 A GB
DIRIS 749 A - DIRIS 742 A
RS485
SOCOMEC B.V.
NL - 3992 De Houten
Tel. +31 (0)30 63 71 504 - Fax +31 (0)30 63 72 166
[email protected]
Réf. DOC 51123 - 04/09 - Photo : Martin Bernhart - Réalisation : SOCOMEC Service Communication - Gyss Imprimeur Obernai
THE NETHERLANDS
Ethernet
The new temperature monitoring
module:
• enhances energy diagnostics
• improves monitoring of facilities
GAMME 115 A GB
ITALY
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement