LevelOne Infinity IES-1881 User manual

Add to My manuals
152 Pages

advertisement

LevelOne Infinity IES-1881 User manual | Manualzz

IES-0883

6 GE + 2 SFP Managed Switch -20 to 60C, DIN-rail

User Manual

v1.00 - 1206

Preface

This manual describes how to install and use the Industrial Managed Gigabit Ethernet

Switch. This switch introduced here is designed to deliver full scalability with SNMP/RMON web-based management functions by providing:

To get the most out of this manual, you should have an understanding of Ethernet networking concepts.

In this manual, you will find:

Features on the Industrial Managed Gigabit Ethernet Switch

· Illustrative LED functions

· Installation instructions

· Management Configuration

· SNMP, IGMP…

· Specifications

IES-0883 User Manual Page 1

Table of Contents

PREFACE ........................................................................................................................................................... 1

QUICK START GUIDE ......................................................................................................................................... 4

P

HYSICAL

D

ESCRIPTION

............................................................................................................................................ 4

F

UNCTIONAL

D

ESCRIPTION

....................................................................................................................................... 6

C

ONSOLE

C

ONFIGURATION

....................................................................................................................................... 6

W

EB

C

ONFIGURATION

............................................................................................................................................. 8

PRODUCT OVERVIEW ....................................................................................................................................... 9

I

NDUSTRIAL

M

ANAGED

G

IGABIT

E

THERNET

S

WITCH

...................................................................................................... 9

P

ACKAGE

C

ONTENTS

................................................................................................................................................ 9

P

RODUCT

H

IGHLIGHTS

........................................................................................................................................... 10

F

RONT

P

ANEL

D

ISPLAY

........................................................................................................................................... 12

P

HYSICAL

P

ORTS

................................................................................................................................................... 14

S

WITCH

M

ANAGEMENT

......................................................................................................................................... 15

INSTALLATION ................................................................................................................................................ 16

S

ELECTING A

S

ITE FOR THE

S

WITCH

........................................................................................................................... 16

W

IRING

D

IAGRAM

................................................................................................................................................ 16

DIN R

AIL

M

OUNTING

............................................................................................................................................ 17

C

ONNECTING TO

P

OWER

........................................................................................................................................ 18

C

ONNECTING TO

Y

OUR

N

ETWORK

............................................................................................................................ 20

SWITCH MANAGEMENT ................................................................................................................................. 21

M

ANAGEMENT

A

CCESS

O

VERVIEW

........................................................................................................................... 21

A

DMINISTRATION

C

ONSOLE

(CLI) ............................................................................................................................ 22

W

EB

M

ANAGEMENT

............................................................................................................................................. 23

SNMP-B

ASED

N

ETWORK

M

ANAGEMENT

................................................................................................................. 23

P

ROTOCOLS

......................................................................................................................................................... 23

M

ANAGEMENT

A

RCHITECTURE

................................................................................................................................ 24

SNMP & RMON MANAGEMENT ..................................................................................................................... 25

O

VERVIEW

........................................................................................................................................................... 25

SNMP A

GENT AND

MIB-2 (RFC 1213) .................................................................................................................. 25

RMON MIB (RFC 2819)

AND

B

RIDGE

MIB (RFC 1493) ........................................................................................... 26

WEB-BASED BROWSER MANAGEMENT ......................................................................................................... 28

L

OGGING ON TO THE SWITCH

................................................................................................................................... 28

U

NDERSTANDING THE

B

ROWSER

I

NTERFACE

............................................................................................................... 29

S

YSTEM

............................................................................................................................................................... 31

P

ORT

.................................................................................................................................................................. 38

S

WITCHING

.......................................................................................................................................................... 41

T

RUNKING

........................................................................................................................................................... 44

STP / R

ING

......................................................................................................................................................... 45

VLAN ................................................................................................................................................................ 51

Q

O

S ................................................................................................................................................................... 55

SNMP ............................................................................................................................................................... 57

802.1

X

.............................................................................................................................................................. 61

O

THER

P

ROTOCOLS

............................................................................................................................................... 64

COMMAND LINE CONSOLE MANAGEMENT ................................................................................................... 68

A

DMINISTRATION

C

ONSOLE

.................................................................................................................................... 68

S

YSTEM

............................................................................................................................................................... 77

P

ORT

.................................................................................................................................................................. 86

IES-0883 User Manual Page 2

S

WITCHING

.......................................................................................................................................................... 90

T

RUNKING

........................................................................................................................................................... 95

STP / R

ING

......................................................................................................................................................... 96

VLAN .............................................................................................................................................................. 109

Q

O

S ................................................................................................................................................................. 115

SNMP ............................................................................................................................................................. 118

802.1

X

............................................................................................................................................................ 127

O

THER

P

ROTOCOLS

............................................................................................................................................. 132

SPECIFICATIONS ........................................................................................................................................... 143

APPENDIX A ................................................................................................................................................. 144

APPENDIX B ................................................................................................................................................. 145

IES-0883 User Manual Page 3

Quick Start Guide

This quick start guide describes how to install and use the Industrial Managed Gigabit

Ethernet Switch. This is the switch of choice for harsh environments constrained by space.

Physical Description

The Port Status LEDs and Power Inputs

Power Input

PW1

PW2

+

+

12 – 32VDC

Power Ground

12 – 32VDC

Power Ground

Earth Ground

Relay Output

1A @ 24VDC

Relay Alarm warning signal disable for following:

1. The relay contact closes if Power1 and Power2 are both failed but Power3 on

2. The relay contact closes if Power3 is failed but Power1 and Power2 are both on

· There are three power inputs can be used. Redundant power function is supported

PW3 is DC Jack type with 12VDC input

IES-0883 User Manual Page 4

LED Status

LED

PW 1,2,3

Status

Steady

Off

Description

10/100/1000Base-TX & 1000Base-FX

LNK/ACT

Steady

Flashing

Network connection established

Transmitting or Receiving data

100

Amber

Green

Off

Connection at 1000Mbps speed

Connection at 100Mbps speed

Connection at 10Mbps speed

Alarm

Power On

Power Off

Alarm

Steady

Off

State the power redundancy failure has being addressed

State the power redundancy failure has not being addressed

IES-0883 User Manual Page 5

Functional Description

· Meets EN61000-6-2 & EN61000-6-4 EMC Generic Standard Immunity for industrial environment.

· Manageable via SNMP, Web-based, Telnet, and RS-232 console port.

· Supports Command Line Interface in RS-232 console.

· Supports IEEE802.3/802.3u/802.3ab/802.3z/802.3x. Auto-negotiation:

10/100/1000Mbps, full/half-duplex. Auto MDI/MDIX.

· 1000Base-SX/LX: Multi mode or Single mode SC type, 1000Base-BX: WDM Single mode

SC type.

·

Supports 4096 MAC addresses. Provides 1M bits memory buffer.

· Store-and-forward mechanism.

· Full wire-speed forwarding rate.

· Alarms for power failure by relay output.

· Operating voltage and Max. current consumption: 1.7A @ 12VDC, 0.85A @ 24VDC.

Power consumption: 20.4W Max.

· Power supply: Redundant DC Terminal Block power inputs and 12VDC DC JACK with

100-240VAC external power supply.

· Field Wiring Terminal Markings: Use Copper Conductors Only, 60/75℃, wire range

12-24 AWG, torque value 7 lb-in.

· -20℃ to 60℃ (-4℉ to 140℉) operating temperature range. UL508 Industrial Control

Equipment certified Maximum Surrounding Air Temperature @ 60℃ (140℉).

· For use in Pollution Degree 2 Environment.

· Supports DIN-Rail and Panel Mounting installation.

Console Configuration

l

Connect to the switch console:

Connect the DB9 straight cable to the RS-232 serial port of the device and the RS-232 serial port of the terminal or computer running the terminal emulation application.

Direct access to the administration console is achieved by directly connecting a terminal or a PC equipped with a terminal-emulation program (such as HyperTerminal) to the switch console port. l

Configuration settings of the terminal-emulation program:

Baud rate: 115,200bps

Data bits: 8

Parity: none

Stop bit: 1

Flow control: none l

Press the “Enter” key. The Command Line Interface (CLI) screen should appear as below: l

Logon to Exec Mode (View Mode):

At the “switch_a login: prompt just type in “root” and press <Enter> to logon to Exec

Mode (or View Mode). And the “switch_a>” prompt will show on the screen.

IES-0883 User Manual Page 6

l

Logon to Privileged Exec Mode (Enable Mode):

At the “switch_a>” prompt just type in “enable” and press <Enter> to logon to

Privileged Exec Mode (or Enable Mode). And the “switch_a#” prompt will show on the screen. l

Logon to Configure Mode (Configure Terminal Mode):

At the “switch_a#” prompt just type in “configure terminal” and press <Enter> to logon to Configure Mode (or Configure Terminal Mode). And the “switch_a(config)#” prompt will show on the screen. l Set new IP address and subnet mask for Switch:

At the “switch_a(config)#” prompt just type in “interface vlan1.1” and press <Enter> to logon to vlan 1 (vlan1.1 means vlan 1). And the “switch_a(config-if)#” prompt will show on the screen.

Command Syntax: “ip address A.B.C.D/M”. “A.B.C.D” specifies IP address. “M” specifies IP subnet mask. “M”= 8: 255.0.0.0, 16:255.255.0.0, or 24: 255.255.255.0.

For example, At the “switch_a(config-if)#” prompt just type in “ip address

192.168.1.10/24” and press <Enter> to set new IP address (192.168.1.10) and new IP subnet mask (255.255.255.0) for Switch.

IES-0883 User Manual Page 7

Web Configuration

l

Login the switch:

Specify the default IP address (192.168.1.10) of the switch in the web browser. A login window will be shown as below: l

Enter the factory default login ID: root.

Enter the factory default password (no password).

Then click on the “Login” button to log on to the switch.

IES-0883 User Manual Page 8

Product Overview

Industrial Managed Gigabit Ethernet Switch

Front and Top View

Package Contents

When you unpack the product package, you shall find the items listed below. Please inspect the contents, and report any apparent damage or missing items immediately to your authorized reseller.

·

IES-0883

· Quick Installation Guide

· CD Users Manual

· RS232 cable

IES-0883 User Manual Page 9

Product Highlights

Basic Features

· Meets EN61000-6-2 & EN61000-6-4 EMC Generic Standard Immunity for industrial environment.

· Manageable via SNMP, Web-based, Telnet, and RS-232 console port.

· Supports Command Line Interface in RS-232 console.

· Supports IEEE802.3/802.3u/802.3ab/802.3z/802.3x. Auto-negotiation:

10/100/1000Mbps, full/half-duplex. Auto MDI/MDIX.

· 1000Base-SX/LX: Multi mode or Single mode SC type, 1000Base-BX: WDM Single mode

SC type.

·

Supports 4096 MAC addresses. Provides 1M bits memory buffer.

· Store-and-forward mechanism.

· Full wire-speed forwarding rate.

· Alarms for power failure by relay output.

· Operating voltage and Max. current consumption: 1.7A @ 12VDC, 0.85A @ 24VDC.

Power consumption: 20.4W Max.

· Power supply: Redundant DC Terminal Block power inputs and 12VDC DC JACK with

100-240VAC external power supply.

· Field Wiring Terminal Markings: Use Copper Conductors Only, 60/75℃, wire range

12-24 AWG, torque value 7 lb-in.

· -20℃ to 60℃ (-4℉ to 140℉) operating temperature range. UL508 Industrial Control

Equipment certified Maximum Surrounding Air Temperature @ 60℃ (140℉).

· For use in Pollution Degree 2 Environment.

· Supports DIN-Rail and Panel Mounting installation.

Management Support

VLAN

l l

Port-based VLAN

IEEE802.1Q tagged VLAN

TRUNKING

l

MAC-based Trunking with automatic link fail-over

PORT-SECURITY

l l l

Per-port programmable MAC address locking

Up to 24 Static Secure MAC addresses per port

IEEE802.1x Port-based Network Access Control

IES-0883 User Manual Page 10

PORT-MIRRORING

l

Port-mirroring

QOS (IEEE802.1p Quality of Service)

l

4 priority queues

INTERNETWORKING PROTOCOLS

l l l l

Bridging:

IEEE802.1s Multiple Spanning Tree

IEEE802.1w Rapid Spanning Tree

IEEE802.1D Spanning Tree compatible

IEEE802.1Q – GVRP

IP Multicast:

IGMP Snooping

Rate Control

NTP

NETWORK MANAGEMENT METHODS

l l l l l

Console port access via RS-232 cable (CLI, Command Line Interface)

Telnet remote access

SNMP agent:

MIB-2 (RFC1213)

Bridge MIB (RFC1493)

RMON MIB (RFC2819) – statistics, history, alarm and events

VLAN MIB (IEEE802.1Q/RFC2674)

Private MIB

Web browser

TFTP software-upgrade capability

IES-0883 User Manual Page 11

Front Panel Display

Power & Port Status LEDs

The LEDs are located on the front panel, displaying status for each respective port. Please refer to the following table for more details.

+

PW1

12 – 32VDC

Power Ground

PW2

+

12 – 32VDC

Power Ground

Earth Ground

Relay Output

1A @ 24VDC

Relay Alarm warning signal disable for following:

3. The relay contact closes if Power1 and Power2 are both failed but Power3 on

4. The relay contact closes if Power3 is failed but Power1 and Power2 are both on

· There are three power inputs can be used. Redundant power function is supported

PW3 is DC Jack type with 12VDC input

IES-0883 User Manual Page 12

LED Status

LED

PW 1,2,3

Status

Steady

Off

Description

10/100/1000Base-TX & 1000Base-FX

LNK/ACT

Steady

Flashing

Network connection established

Transmitting or Receiving data

100

Amber

Green

Off

Connection at 1000Mbps speed

Connection at 100Mbps speed

Connection at 10Mbps speed

Alarm

Power On

Power Off

Alarm

Steady

Off

State the power redundancy failure has being addressed

State the power redundancy failure has not being addressed

IES-0883 User Manual Page 13

Physical Ports

The Industrial Managed Gigabit Ethernet Switch provides:

8-port Industrial Managed Gigabit Ethernet Switch

CONNECTIVITY

· RJ-45 connectors on TX ports

· SC connector on 1000Base-SX/LX/BX fiber port

MODE SELECTION

· 10Base-T full-duplex mode

· 10Base-T half-duplex mode

·

100Base-TX full-duplex mode

· 100Base-TX half-duplex mode

· 1000Base-T/SX/LX/BX full-duplex mode

· Auto-negotiating mode

IES-0883 User Manual Page 14

Switch Management

Web-based browser interface

The switch also boasts a point-and-click browser-based interface that lets user access full switch configuration and functionality from a Netscape or Internet Explorer browser.

Administration console via RS-232 serial port (CLI)

The switch provides an onboard serial port, which allows the switch to be configured via a directly connected terminal.

External SNMP-based network management application

The switch can also be configured via SNMP.

IES-0883 User Manual Page 15

Installation

This chapter gives step-by-step instructions about how to install the switch:

Selecting a Site for the Switch

As with any electric device, you should place the switch where it will not be subjected to extreme temperatures, humidity, or electromagnetic interference. Specifically, the site you select should meet the following requirements:

-The ambient temperature should be between -20°C to 60℃ (-4℉ to 140℉).

-The relative humidity should be less than 95 percent, non-condensing.

-Surrounding electrical devices should not exceed the electromagnetic field (RFC) standards.

-Make sure that the switch receives adequate ventilation. Do not block the ventilation holes on each side of the switch.

Wiring Diagram

Field Wiring Terminal Markings: Use Copper Conductors Only, 60/75℃, wire range 12-24

AWG, torque value 7 lb-in.

IES-0883 User Manual Page 16

DIN Rail Mounting

Fix the DIN rail attachment plate to the back panel of the Industrial Managed Ethernet

Extender.

Installation: Place the Industrial Managed Ethernet Extender on the DIN rail from above using the slot. Push the front of the Industrial Managed Ethernet Extender toward the mounting surface until it audibly snaps into place.

Removal: Pull out the lower edge and then remove the Industrial Managed Ethernet

Extender from the DIN rail.

IES-0883 User Manual Page 17

Connecting to Power

Redundant DC Terminal Block Power Inputs or 12VDC DC Jack:

12VDC DC Jack

Step 1: Connect the supplied AC to DC power adapter to the receptacle on the topside of the switch.

Step 2: Connect the power cord to the AC to DC power adapter and attach the plug into a standard AC outlet with the appropriate AC voltage.

Redundant DC Terminal Block Power Inputs

There are two pairs of power inputs for use with redundant power sources. You only need to have one power input connected to run the switch.

Step 1: Connect the DC power cord to the plug-able terminal block on the switch, and then plug it into a standard DC outlet.

Step 2: Disconnect the power cord if you want to shut down the switch.

Top View

IES-0883 User Manual Page 18

Alarms for Power Failure

Step 1: There are two pins on the terminal block used for power failure detection. It provides the normally closed output when the power source is active. Use this as a dry contact application to send a signal for power failure detection.

+

12 – 32VDC

PW1

Power Ground

PW2

+

12 – 32VDC

Power Ground

Earth Ground

Relay Output

1A @ 24VDC

Relay Alarm warning signal disable for following:

5. The relay contact closes if Power1 and Power2 are both failed but Power3 on

6. The relay contact closes if Power3 is failed but Power1 and Power2 are both on

Special note:

The relay output is normal open position when there is no power to the switch.

Please do not connect any power source to this terminal to prevent shorting your power supply.

IES-0883 User Manual Page 19

Connecting to Your Network

Cable Type & Length

100Base-TX

1000Base-T

100Base-FX

100Base-FX

100Base-BX

100Base-BX

1000Base-SX

1000Base-SX

1000Base-LX

1000Base-BX

SFP

1000Base-SX

1000Base-LX

1000Base-BX

It is necessary to follow the cable specifications below when connecting the switch to your network. Use appropriate cables that meet your speed and cabling requirements.

Cable Specifications

Speed Connector Port Speed

Half/Full Duplex

Cable Max. Distance

10Base-T RJ-45 10/20 Mbps 2-pair UTP/STP Cat. 3, 4, 5 100 m

SC

SC

SC

SC

RJ-45

RJ-45

ST, SC

ST, SC

SC

SC

100/200 Mbps

2000 Mbps

200 Mbps

200 Mbps

200 Mbps

200 Mbps

2000 Mbps

2000 Mbps

2000 Mbps

2000 Mbps

2-pair UTP/STP Cat. 5

4-pair UTP/STP Cat. 5

MMF (62.5µm)

SMF (10µm)

MMF (62.5µm)

SMF (10µm)

MMF (62.5µm)

MMF (50µm)

SMF (10µm)

SMF (10µm)

100 m

100 m

2 km

20, 40, 75, 100 km

2, 5 km

20, 40 km

220 m, 2 km

550 m

10, 20, 50 km

20, 40 km

Duplex LC

Duplex LC

Duplex LC

2000 Mbps

2000 Mbps

2000 Mbps

MMF (62.5µm)

SMF (9µm)

SMF (9µm)

550 m, 2 km

10, 40, 60 km

70 km

Cabling

Step 1: First, ensure the power of the switch and end devices are turned off.

<Note> Always ensure that the power is off before any installation.

Step 2: Prepare cable with corresponding connectors for each type of port in use.

Step 3: Consult Cable Specifications Table on previous page for cabling requirements based on connectors and speed.

Step 4: Connect one end of the cable to the switch and the other end to a desired device.

Step 5: Once the connections between two end devices are made successfully, turn on the power and the switch is operational.

IES-0883 User Manual Page 20

Switch Management

This chapter explains the methods that you can use to configure management access to the switch. It describes the types of management applications and the communication and management protocols that deliver data between your management device

(workstation or personal computer) and the system. It also contains information about port connection options.

This chapter covers the following topics:

Management Access Overview

Key Concepts

Key Guidelines for Implementation

Web Management Access

Administration Console Access

SNMP Access

Standards, Protocols, and Related Reading

Management Access Overview

The switch gives you the flexibility to access and manage the switch using any or all of the following methods.

The web browser interface and administration console (CLI) support are embedded in the switch software and are available for immediate use.

IES-0883 User Manual Page 21

Administration Console (CLI)

The administration console is an internal, character-oriented, Command Line Interface (CLI) for performing system administration such as displaying statistics or changing option settings. Using this method, you can view the administration console from a terminal, personal computer, Apple Macintosh, or workstation connected to the switch’s console port.

There are two ways to use this management method: direct access or modem access. The following sections describe these methods.

Direct Access

Direct access to the administration console is achieved by directly connecting a terminal or a PC equipped with a terminal-emulation program (such as HyperTerminal) to the switch console port. When using the management method, configure the terminal-emulation program to use the following parameters (you can change these settings after login):

[DEFAULT PARAMETERS]

¨ 115,200bps

¨ 8 data bits

¨ No parity

¨ 1 stop bit

This management method is often preferred because you can remain connected and monitor the system during system reboots. Also, certain error messages are sent to the serial port, regardless of the interface through which the associated action was initiated. A

Macintosh or PC attachment can use any terminal-emulation program for connecting to the terminal serial port. A workstation attachment under UNIX can use an emulator such as TIP.

Modem Access

You can access the switch’s administration console from a PC or Macintosh using an external modem attached to the console port. The switch management program provides

Console Port screen, accessible from the Basic Management screen that lets you configure parameters for modem access.

When you have configured the external modem from the administration console, the switch transmits characters that you have entered as output on the modem port. The switch echoes characters that it receives as input on the modem port to the current administration console session. The console appears to be directly connected to the external modem.

IES-0883 User Manual Page 22

Web Management

The switch provides a browser interface that lets you configure and manage the switch remotely.

After you set up your IP address for the switch, you can access the switch’s web interface applications directly in your web browser by entering the IP address of the switch. You can then use your web browser to list and manage switch configuration parameters from one central location, just as if you were directly connected to the switch’s console port.

SNMP-Based Network Management

You can use an external SNMP-based application to configure and manage the switch. This management method requires the SNMP agent on the switch and the SNMP Network

Management Station to use the same community string. This management method, in fact, uses two community strings: the get community string and the set community string. If the SNMP Network management station only knows the set community string, it can read and write to the MIBs. However, if it only knows the get community string, it can only read

MIBs. The default get and set community strings for the switch are public.

Protocols

The switch supports the following protocols:

VIRTUAL TERMINAL PROTOCOLS, SUCH AS TELNET

A virtual terminal protocol is a so ftware program, such as Telnet, that allows you to establish a management session from a M acintosh, a PC, or a UNIX workstation. Because Telnet runs over TCP/IP, you must have at least one IP address configured on the switch before you can establish access to it with a virtual terminal protocol.

<Note> Terminal emulation is different from a virtual terminal protocol in that you must connect a terminal directly to the console port.

SIMPLE NETWORK MANAGEMENT PROTOCOL (SNMP)

SNMP is the standard management protocol for multivendor IP networks.

SNMP supports transaction-based queries that allow the protocol to format messages and to transmit information between reporting devices and data-collection programs. SNMP runs on top of the User Datagram Protocol

(UDP), offering a connectionless-mode service.

IES-0883 User Manual Page 23

Management Architecture

All of the management application modules use the same Messaging Application

Programming Interface (MAPI). By unifying management methods with a single MAPI, configuration parameters set using one method (e.g. console port) are immediately displayed the other management methods (e.g. SNMP agent of web browser).

The management architecture of the switch adheres to the IEEE open standard. This compliance assures customers that the switch is compatible with, and will interoperate with other solutions that adhere to the same open standard.

IES-0883 User Manual Page 24

SNMP & RMON Management

This chapter describes the switch’s Simple Network Management Protocol (SNMP) and

Remote Monitoring (RMON) capabilities.

Overview

RMON is an abbreviation for the Remote Monitoring MIB (Management Information Base).

RMON is a system defined by the Internet Engineering Task Force (IETF) document RFC

2819, which defines how networks can be monitored remotely.

RMONs typically consist of two components: an RMON probe and a management workstation:

-

The RMON probe is an intelligent device or software agent that continually collects statistics about a LAN segment or VLAN. The RMON probe transfers the collected data to a m anagement workstation on request or when a pre-defined threshold is reached.

-

The management workstation collects the statistics that the RMON probe gathers. The workstation can reside on the same network as the probe, or it can have an in-band or out-of-band connection to the probe.

The switch provides RMON capabilities that allow network administrators to set parameters and view statistical counters defined in MIB-II, Bridge MIB, and RMON MIB.

RMON activities are performed at a Network Management Station running an SNMP network management application with graphical user interface.

SNMP Agent and MIB-2 (RFC 1213)

The SNMP Agent running on the switch manager CPU is responsible for:

-

Retrieving MIB counters from various layers of software modules according to the SNMP GET/GET NEXT frame messages.

-

Setting MIB variables according to the SNMP SET frame message.

-

Generating an SNMP TRAP frame message to the Network Management

Station if the threshold of a certain MIB counter is reached or if other trap conditions (such as the following) are met:

IES-0883 User Manual Page 25

WARM START

COLD START

LINK UP

LINK DOWN

AUTHENTICATION FAILURE

RISING ALARM

FALLING ALARM

TOPOLOGY ALARM

MIB-II defines a set of manageable objects in various layers of the TCP/IP protocol suites.

MIB-II covers all manageable objects from layer 1 to layer 4, and, as a result, is the major

SNMP MIB supported by all vendors in the networking industry. The switch supports a complete implementation of SNMP Agent and MIB-II.

RMON MIB (RFC 2819) and Bridge MIB (RFC 1493)

The switch provides hardware-based RMON counters in the switch chipset. The switch manager CPU polls these counters periodically to collect the statistics in a format that complies with the RMON MIB definition.

RMON Groups Supported

The switch supports the following RMON MIB groups defined in RFC 2819:

-

RMON Statistics Group – maintains utilization and error statistics for the switch port being monitored.

-

RMON History Group – gathers and stores periodic statistical samples from the previous Statistics Group.

-

RMON Alarm Group – allows a network administrator to define alarm thresholds for any MIB variable. An alarm can be associated with Low

Threshold, High Threshold, or both. A trigger can trigger an alarm when the value of a specific MIB variable exceeds a threshold, falls below a threshold, or exceeds or falls below a threshold.

-

RMON Event Group – allows a network administrator to define actions based on alarms. SNMP Traps are generated when RMON Alarms are triggered. The action taken in the Network Management Station depends on the specific network management application.

IES-0883 User Manual Page 26

Bridge Groups Supported

The switch supports the following four groups of Bridge MIB (RFC 1493):

-

The dot1dBase Group – a mandatory group that contains the objects applicable to all types of bridges.

-

The dot1dStp Group – contains objects that denote the bridge’s state with respect to the Spanning Tree Protocol. If a node does not implement the

Spanning Tree Protocol, this group will not be implemented. This group is applicable to any transparent only, source route, or SRT bridge that implements the Spanning Tree Protocol.

-

The dot1dTp Group – contains objects that describe the entity’s transparent bridging status. This group is applicable to transparent operation only and

SRT bridges.

-

The dot1dStatic Group – contains objects that describe the entity’s destination-address filtering status. This group is applicable to any type of bridge which performs destination-address filtering.

IES-0883 User Manual Page 27

Web-Based Browser Management

The switch provides a web-based browser interface for configuring and managing the switch. This interface allows you to access the switch using a preferred web browser.

This chapter describes how to configure the switch using its web-based browser interface.

Logging on to the switch

SWITCH IP ADDRESS

In your web browser, specify the IP address of the switch. Default IP address is

192.168.1.10.

LOGIN

Enter the factory default login ID: root.

PASSWORD

Enter the factory default password (no password).

Or enter a user-defined password if you followed the instructions later and changed the factory default password.

Then click on the “Login” button to log on to the switch.

IES-0883 User Manual Page 28

Understanding the Browser Interface

The web browser interface provides groups of point-and-click buttons at the left field of the screen for configuring and managing the switch.

SYSTEM

System Information, System Name/Password, IP Address, Save Configuration,

Firmware Upgrade, Reboot, Logout

PORT

Configuration, Port Status, Rate Control, RMON Statistics, Per Port Vlan

Activities

SWITCHING

Bridging, Static MAC Entry, Port Mirroring

TRUNKING

Port Trunking

STP / RING

Global Configuration, RSTP Port Setting, MSTP Properties, MSTP Instance Setting, MSTP

Port Setting, Ring Setting

VLAN

VLAN Mode Setting, 802.1Q VLAN Setting, 802.1Q Port Setting, Port Based

VLAN

IES-0883 User Manual Page 29

QOS

Global Configuration, 802.1p Priority, DSCP

SNMP

SNMP General Setting, SNMP v1/v2c, SNMP v3

802.1X

Radius Configuration, Port Authentication

OTHER PROTOCOLS

GVRP, IGMP Snooping, NTP

IES-0883 User Manual Page 30

System

System Information

View System information, VLAN ID, IP Address, and IP Subnet Mask of the Switch.

System Name/Password

1. System Name: Click in “System Name” text box. Type a system name if it is blank, or replace the current system name with a new one.

2. Updating setting: Click “Updating setting” button to update your settings.

3. Password: Click in “Password” text box. Type a password.

4. Retype Password: Click in “Retype Password” text box. Type the same password in

“Password” text box again to verify it.

5. Updating setting: Click “Updating setting” button to update your settings.

IES-0883 User Manual Page 31

IP Address

1. IP Address: Click in “IP Address” text box and type a new address to change the IP

Address.

2. IP Subnet Mask: Click in “IP Subnet Mask” text box and type a new address to change the IP Subnet Mask.

3. Submit: Click “Submit” button when you finished these selections.

4. You need to enter the new IP address on the browser and reconnect to the switch after

IP or subnet mask are changed.

5. Default Gateway: Click “Default Gateway” drop-down menu to choose “Disable” or

“Enable” from the “Default Gateway” drop-down list to disable or enable Default

Gateway Setting for the switch.

Click the text box and type a new address to change the Default Gateway. (Need to choose “Enable” from the “Default Gateway” drop-down menu.)

6. Submit: Click “Submit” button when you finished Default Gateway.

7. DNS Server: Click “DNS Server” drop-down menu to choose “Disable” or “Enable” from the “DNS Server” drop-down list to disable or enable DNS Server Setting for the switch.

Click the text box and type a new address to change the DNS Server. (Need to choose

“Enable” from the “DNS Server” drop-down menu.)

8. Submit: Click “Submit” button when you finished DNS Server.

IES-0883 User Manual Page 32

Save Configuration

1. Load config from TFTP server:

Click in “TFTP Server” text box and type the TFTP server IP address from where the file will be obtained.

Click in “FILE” text box and type the name of the file that will be obtained.

Click “Load” button to load the file from the TFTP server.

2. Backup config to TFTP server:

Click in “TFTP Server” text box and type the TFTP server IP address to where the file will be backupped.

Click in “FILE” text box and type the name of the file that will be backupped.

Click “Backup” button to backup the file to the TFTP server.

3. Save Configuration: Click “Save Configuration” button to save your configuration settings.

4. Restore Default: Click “Restore Default” button to restore the default settings of the switch.

5. Auto save: Click “Auto save” drop-down menu to choose “Disable” or “Enable” from the

“Auto save” drop-down list to disable or enable Auto save for the switch.

6. Auto save interval (5~65536 sec): Click in “Auto save interval” text box and type a decimal number between 5 and 65536.

7. Submit: Click “Submit” button when you finished Auto save configuration.

IES-0883 User Manual Page 33

Firmware Upgrade

1. Filename: Click in “Filename” text box and type the name of the file that you intend to upgrade it to the switch.

2. TFTP server IP: Click in “TFTP server IP” text box and type the TFTP server IP address from where the file will be obtained.

3. Upgrade: Click “upgrade” button to upgrade firmware to the switch. Please follow the message on the screen during the firmware upgrade process. Do not turn off the power or perform other functions during this period of time. Reboot the switch after completing the upgrade process.

Please follow the message on the screen during the firmware upgrade process. Do not turn off the power or perform other functions during this period of time.

IES-0883 User Manual Page 34

Firmware has been upgraded successfully to the switch. Reboot the switch after completing the upgrade process.

IES-0883 User Manual Page 35

Reboot

Reboot: Click “Reboot” button to restart the switch.

IES-0883 User Manual Page 36

Logout

Logout: Click “Logout” button to logout of the switch.

IES-0883 User Manual Page 37

Port

Configuration

1. Admin Setting: Click “Admin Setting” drop-down menu to choose “Link down” or “Link up” from the “Admin Setting” drop-down list to disable or enable Admin Setting for the port.

2. Speed: Click “Speed” drop-down menu to change the line speed and duplex settings from the “Speed” drop-down list for the port.

3. Flow control: Click “Flow control” drop-down menu to choose “Disable” or “Enable” from the “Flow control” drop-down list to disable or enable Flow control for the port.

4. Submit: Click “Submit” button when you finished configurations.

IES-0883 User Manual Page 38

Port Status

View the Link Status, Speed, Duplex, and Flow control status for all ports.

Rate Control

1. Ingress: Click in “Ingress” text box and type a new Rate to change the Ingress Rate

Control for the port.

Rate Values: 64kbps, 128kbps, 192kbps, … , 1792kbps.

2Mbps, 3Mbps, 4Mbps, … , 100Mbps.

104Mbps, 112Mbps, 120Mbps, … , 1000Mbps.

<Note>: M = 1024k.

2. Egress: Click in “Egress” text box and type a new Rate to change the Egress Rate Control for the port.

Rate Values: 64kbps, 128kbps, 192kbps, … , 1792kbps.

2Mbps, 3Mbps, 4Mbps, … , 100Mbps.

104Mbps, 112Mbps, 120Mbps, … , 1000Mbps.

<Note>: M = 1024k.

3. Update setting: Click “Update setting” button when you finished these Rate Control settings.

IES-0883 User Manual Page 39

RMON Statistics

Click Port 1 ~ Port 8 to view corresponding RMON Statistics.

Per port vlan activities

Click Port 1 ~ Port 8 to view corresponding vlan activities.

IES-0883 User Manual Page 40

Switching

Bridging

1. Aging Time (seconds): Click the text box and type a decimal number as Bridging Aging

Time in seconds.

2. Update setting: Click “update setting” button when you finished Aging Time settings.

3. Threshold level (0-100): Click in “Level” text box and type a decimal number for the port.

Need to choose “Broadcast” and/or “DFL-Multicast“ from “Storm-control enabled type” for the port. DLF (Destination Lookup Failure).

4. Storm-control enabled type: Choose “Broadcast” and/or “DLF-Multicast” from

“Storm-control enabled type” for the port.

5. Update Setting: Click “Update Setting” button when you finished Threshold level and

Storm-control enabled type settings.

IES-0883 User Manual Page 41

Static MAC entry

Static-MAC-Entry Forward:

1. Add MAC address: Click in “Add MAC address” text box and type a locked forwarding

MAC address for the port.

2. VLAN ID: Click “VLAN ID” drop-down menu and choose a VLAN ID from the “VLAN ID” drop-down list.

3. Delete MAC address: Click “Delete MAC address” drop-down menu and choose a locked forwarding MAC address from the “Delete MAC address” drop-down list to be deleted from the port.

4. Submit: Click “Submit” button when you finished Static-MAC-Entry Forward settings.

Static-MAC-Entry Discard:

1. Add MAC address: Click in “Add MAC address” text box and type a MAC address to be discarded for the VLAN.

2. VLAN ID: VLAN ID: Click “VLAN ID” drop-down menu and choose a VLAN ID from the

“VLAN ID” drop-down list.

3. Delete MAC address: Click “Delete MAC address” drop-down menu and choose a MAC address from the “Delete MAC address” drop-down list to be discarded from the VLAN.

4. Submit: Click “Submit” button when you finished Static-MAC-Entry Discard settings.

IES-0883 User Manual Page 42

Port Mirroring

1. Mirror From: Choose Mirror From port from Port 1 ~ Port 8.

2. Mirror To: Click “Mirror To” drop-down menu to Choose Mirror To port (Port 1 ~ Port 8) from “Mirror To” drop-down list.

3. Mirror Mode: Click “Mirror Mode” drop-down menu to Choose “Tx/Rx”, “Tx”, or “Rx” from

“Mirror Mode” drop-down list.

4. Submit: Click “Submit” button when you finished Port Mirroring settings.

IES-0883 User Manual Page 43

Trunking

Port Trunking

Static Channel Group:

1. Trunk 1 ~ 4: Trunk 1: Click Port 1 ~ Port 8 to assign ports to Trunk 1 ~ 4. (Maximum 4 ports per Trunk.)

2. Submit: Click “Submit” button when you finished Port Trunking settings.

IES-0883 User Manual Page 44

STP / Ring

Global Configuration

1. Spanning Tree Protocol: Click “Spanning Tree Protocol” drop-down menu to Choose

“Enable” or “Disable” from “Spanning Tree Protocol” drop-down list to enable or disable

Spanning Tree Protocol.

2. Bridge Priority (0..61440): Click in “Bridge Priority” text box and type a decimal number between 0 and 61440.

3. Hello Time (sec) (1..9): Click in “Hello Time” text box and type a decimal number between 1 and 9.

4. Max Age (sec) (6..28): Click in “Max Age” text box and type a decimal number between

6 and 28.

5. Forward Delay (sec) (4..30): Click in “Forward Delay” text box and type a decimal number between 4 and 30.

6. STP Version: Click “STP Version” drop-down menu to choose “MSTP”, “RSTP”, or “STP compatible” from “STP Version” drop-down list.

7. Update setting: Click “Update setting” button when you finished Global Configuration.

IES-0883 User Manual Page 45

RSTP Port Setting

1. STP Version: Click “STP Version” drop-down menu to choose “RSTP” from “STP Version” drop-down list.

2. Port: Click “Port” drop-down menu to Choose Port 1 ~ Port 8 from “Port” drop-down list.

3. Priority(Granularity 16): Click in “Priority” text box and enter a value between 0 and 240 to set the priority for the port. A higher priority will designate the port to forward packets first. A lower number denotes a higher priority. This entry must be divisible by

16. The default priority setting is 128.

4. Admin. Path Cost: Click in “Admin. Path Cost” text box and enter a value between 0 and

2000000 to set the Admin. Path Cost for the port. 0 (auto) - Setting 0 for the Admin.

Path Cost will automatically set the speed for forwarding packets to the port for optimal efficiency. Default port cost: 100Mbps port = 200000. Gigabit port = 20000.

5. Point to Point Link: Click “Point to Point Link” drop-down menu to Choose “Enable” or

“Disable” from “Point to Point Link” drop-down list to enable or disable Point to Point

Link for the port.

6. Edge Port: Click “Edge Port” drop-down menu to Choose “Enable”, “Disable”, or “Auto” from “Edge Port” drop-down list to set Enable, Disable, or Auto Edge Port for the port.

7. Update setting: Click “Update setting” button when you finished RSTP Port Setting.

IES-0883 User Manual Page 46

MSTP Properties

1. STP Version: Click “STP Version” drop-down menu to choose “MSTP” from “STP Version” drop-down list.

2. Region Name: Click in “Region Name” text box to create an MST region and specify a name to it. MST bridges of a region form different spanning trees for different VLANs.

By default, each MST bridge starts with the region name as its bridge address. This means each MST bridge is a region by itself, unless specifically added to one.

3. Revision Level: Click in “Revision Level” text box to specify the number for configuration information. The default value of revision number is 0.

4. Max Hops: Click in “Max Hops” text box to specify the maximum allowed hops for BPDU in an MST region. This parameter is used by all the instances of the MST. Specifying the max hops for a BPDU prevents the messages from looping indefinetely in the network.

When a bridge receives a MST BPDU that has exceeded the allowed max-hops, it discards the BPDU.

5. Update setting: Click “Update setting” button when you finished MSTP Properties setting.

IES-0883 User Manual Page 47

MSTP Instance Setting

VLAN Instance Configuration

1. VLAN Instance Configuration: Click “VLAN Instance Configuration” button. The “VLAN

Instance Configuration” window appears.

2. VLAN ID: Click “VLAN ID” drop-down menu to choose VLAN from “VLAN ID” drop-down list to simultaneously add multiple VLANs for the corresponding instance of a bridge.

3. Instance ID (1..15): Click in “Instance ID” text box to specify the instance ID.

4. Update setting: Click “Update setting” button when you finished VLAN Instance

Configuration.

Included VLANs

1. Instance ID: Click “Instance ID” drop-down menu to choose instance ID from “Instance

ID” drop-down list.

2. Included VLAN: Click “Included VLAN” drop-down menu to choose VLAN from

“Included VLAN” drop-down list.

Instance Setting

1. Bridge Priority (0..61440): Click in “Bridge Priority” text box to set the bridge priority for an MST instance to the value specified. The lower the priority of the bridge, the better the chances are the bridge becoming a root bridge or a designated bridge for the LAN.

2. Update setting: Click “Update setting” button when you finished VLAN Instance

Configuration.

IES-0883 User Manual Page 48

MSTP Port Setting

Port Instance Configuration

1. Instance ID: Click “Instance ID” drop-down menu to choose instance ID from “Instance

ID” drop-down list.

2. Click Port 1 ~ Port 8 to assign ports to the corresponding instance ID.

3. Update setting: Click “Update setting” button when you finished Port Instance

Configuration.

Instance ID

1. Instance ID: Click “Instance ID” drop-down menu to choose instance ID from “Instance

ID” drop-down list.

MSTP Port Configuration

1. Port: Click “Port” drop-down menu to choose port from “Port” drop-down list.

2. Priority(Granularity 16): Click in “Priority” text box to set the port priority for a bridge group. The Multiple Spanning Tree Protocol uses port priority as a tiebreaker to determine which port should forward frames for a particular instance on a LAN , or which port should be the root port for an instance. A lower value implies a better priority. In the case of the same priority, the interface index will serve as the tiebreaker, with the lower-numbered interface being preferred over others. The permitted range is 0-240. The priority values can only be set in increments of 16.

3. Admin. Path Cost: Click in “Admin. Path Cost” text box to set the cost of a path associated with an interface.

4. Update setting: Click “Update setting” button when you finished MSTP Port Setting.

IES-0883 User Manual Page 49

Ring Setting

Ring state

1. Click “Ring state” drop-down menu from “Ring state” drop-down list to choose “Enable” or “Disable” to enable or disable Ring state.

2. Update Setting: Click “Update Setting” button when you finished Ring state setting.

Set ring port

1. Ring port 1: Click “Ring port 1” drop-down menu to choose Ring port 1 from “Ring port

1” drop-down list.

2. Ring port 2: Click “Ring port 2” drop-down menu to choose Ring port 2 from “Ring port

2” drop-down list.

3. Update setting: Click “Update setting” button when you finished Set ring port.

IES-0883 User Manual Page 50

VLAN

VLAN Mode Setting

1. VLAN Mode Setting: Click “VLAN Mode Setting” drop-down menu to choose

“Tag-based VLAN” or “Port-based VLAN” from “VLAN Mode Setting” drop-down list.

2. Update Setting: Click “Update Setting” button when you finished VLAN Mode Setting.

IES-0883 User Manual Page 51

802.1Q VLAN Setting

Add VLAN:

1. VLAN setting: Click “VLAN setting”. The “VLAN Setting” window appears.

2. Add VLAN: Click “Add VLAN” button to create a new VLAN from “VLAN Setting” window.

3. VLAN ID(2-4094): Click in the “VLAN ID” textbox and specify a new VLAN ID number from 2 ~ 4094.

4. VLAN Name: Click in the “VLAN Name” textbox and type a name for this newly created

VLAN.

Add port to or delete port from VLAN:

1. VLAN Member: Choose the port to be added to or deleted from the VLAN.

2. Tag or Untag: Click “Tag or Untag” drop-down menu to Choose “Tag” or “Untag” from

“Tag or Untag” drop-down list for a “Hybrid” port.

3. Submit: Click “Submit” button when you finished VLAN setting.

Delete VLAN:

1. VLAN setting: Click “VLAN setting”. The “VLAN Setting” window appears.

IES-0883 User Manual Page 52

2. Delete VLAN: Click “Delete VLAN” button.

3. Select a VLAN ID: Click “Select a VLAN ID” drop-down menu from “Select a VLAN ID” drop-down list to choose the VLAN to be deleted.

4. Submit: Click “Submit” button when you finished VLAN setting.

VLAN Port Setting

1. VLAN Port Setting: Click “VLAN Port Setting”. The “VLAN Port Setting” window appears.

2. Mode: Click “Mode” drop-down menu to choose “Access”, “Trunk”, or “Hybrid” from

“Mode” drop-down list for the port. The port will be Tag port if you choose “Trunk”

Mode for the port. And the port will be Tag or Untag port if you choose “Hybrid” Mode for the port.

3. PVID: Click in the “PVID” textbox and specify a new PVID number for the port.

4. Update Setting: Click “Update Setting” button when you finished VLAN Port Setting.

IES-0883 User Manual Page 53

Port Based VLAN

1. VLAN: Choose the port to be added to or deleted from the VLAN.

2. Select all: Click “select all” button to choose Port 1 ~ Port 8 all to be added to the VLAN.

3. Delete all: Click “delete all” button to choose Port 1 ~ Port 8 all to be deleted from the

VLAN.

4. Submit: Click “Submit” button when you finished Port Based VLAN setting.

IES-0883 User Manual Page 54

QoS

Global Configuration

1. QoS: Click “QoS” drop-down menu from “QoS” drop-down list to choose “Enable” or

“Disable” to enable or disable QoS.

2. Trust: Enable or disable the switch port to trust the CoS (Class of Service) labels of all traffic received on that port. Enable or disable a routed port to trust the DSCP

(Differentiated Service Code Point) labels of all traffic received on that port.

3. Policy: Choose “Strict Priority(Queue3) + WRR(Queue0-2)” or “WRR(Queue0-3)”. A strict priority queue is always emptied first. The queues that are used in the WRR (Weighted

Round Robin) are emptied in a round−robin fashion, and you can configure the weight for each queue.

4. Weighted Round Robin: Click in the “Weight(1~55)” textbox and specify a new number from 1 ~ 55 for Queue 0 ~ 3.

5. Submit: Click “Submit” button when you finished Global Configuration.

IES-0883 User Manual Page 55

802.1p Priority

1. Priority: Click “Priority” drop-down menu from “Priority” drop-down list to choose 0 ~ 3 for VLAN Priority 0 ~ 7.

2. Submit: Click “Submit” button when you finished 802.1p priority.

DSCP

1. Priority: Click “Priority” drop-down menu from “Priority” drop-down list to choose 0 ~ 3 for DSCP Priority 0 ~ 63.

2. Submit: Click “Submit” button when you finished DSCP.

IES-0883 User Manual Page 56

SNMP

SNMP General Setting

1. SNMP Status: Click “SNMP Status” drop-down menu from “SNMP Status” drop-down list to choose “Enable” or “Disable” to enable or disable SNMP.

2. Description: Click in the “Description” textbox and specify a new description for SNMP.

3. Location: Click in the “Location” textbox and specify a new location for SNMP.

4. Contact: Click in the “Contact” textbox and specify a new contact for SNMP.

5. Trap Community Name: For each “Trap Community Name”, Click in the “Trap

Community Name” textbox and specify a trap community name.

6. Trap Host IP Address: For each “Trap Host IP Address”, Click in the “Trap Host IP Address” textbox and specify a trap host IP address.

7. Cold Start Trap: Click “Cold Start Trap” drop-down menu from “Cold Start Trap” drop-down list to choose “Enable” or “Disable” to enable or disable cold start trap.

8. Warm Start Trap: Click “Warm Start Trap” drop-down menu from “Warm Start Trap” drop-down list to choose “Enable” or “Disable” to enable or disable warm start trap.

9. Link Down Trap: Click “Link Down Trap” drop-down menu from “Link Down Trap” drop-down list to choose “Enable” or “Disable” to enable or disable link down trap.

10. Link Up Trap: Click “Link Up Trap” drop-down menu from “Link Up Trap” drop-down list to choose “Enable” or “Disable” to enable or disable link up trap.

11. Authentication Failure Trap: Click “Authentication Failure Trap” drop-down menu from

“Authentication Failure Trap” drop-down list to choose “Enable” or “Disable” to enable or disable authentication failure trap.

IES-0883 User Manual Page 57

12. Topology Change Trap: Click “Topology Change Trap” drop-down menu from “Topology

Change Trap” drop-down list to choose “Enable” or “Disable” to enable or disable topology change trap.

13. Update Setting: Click “Update Setting” button when you finished SNMP General

Setting.

SNMP v1/v2c

1. Get Community Name: Click in the “Get Community Name” textbox and specify a get community name.

2. Set Community Name: Click in the “Set Community Name” textbox and specify a set community name.

3. Update Setting: Click “Update Setting” button when you finished SNMP V1/V2c Setting.

IES-0883 User Manual Page 58

SNMP v3

Add User:

1. Add User: Click “Add User” button. The “SNMP V3 Setting” window appears.

2. SNMP Version: Click “SNMP Version” drop-down menu from “SNMP Version” drop-down list to choose “SNMPv3 No-Auth”, “SNMPv3 Auth-MD5”, “SNMPv3 Auth-SHA”, “SNMPv3

Priv Auth-MD5”, or “SNMPv3 Priv Auth-SHA”.

Ÿ

SNMPv3 No-Auth: Add a user using SNMP v3 without authentication.

Ÿ

SNMPv3 Auth-MD5: Add a user using SNMP v3 with authentication. Click in the “Auth.

Password” textbox and specify an authentication password.

Ÿ

SNMPv3 Auth-SHA: Add a user using SNMP v3 with authentication. Click in the “Auth.

Password” textbox and specify an authentication password.

Ÿ SNMPv3 Priv Auth-MD5: Add a user using SNMP v3 with authentication and privacy.

Click in the “Auth. Password” textbox and specify an authentication password. Click in the “Privacy PassPhrase” textbox and specify a privacy pass phrase.

Ÿ

SNMPv3 Priv Auth-SHA: Add a user using SNMP v3 with authentication and privacy.

Click in the “Auth. Password” textbox and specify an authentication password. Click in the “Privacy PassPhrase” textbox and specify a privacy pass phrase.

3. User Name: Click in the “User Name” textbox and specify a user name for user using

SNMP v3.

4. Access Mode: Click “Access Mode” drop-down menu from “Access Mode” drop-down list to choose “Read Only” or “Read/Write”.

Ÿ

Read Only: Add a user using SNMP v3 with read-only access mode.

Ÿ

Read/Write: Add an user using SNMP v3 with read-write access mode

5. Sumit: Click “Sumit” button when you finished SNMP V3 Setting.

IES-0883 User Manual Page 59

Delete User:

1. Delete User: Click “Delete User” button. The “Select User Name” window appears.

2. Select User Name: Click “Select User Name” drop-down menu from “Select User Name” drop-down list to choose the user to be deleted from using SNMP v3.

3. Sumit: Click “Sumit” button when you finished user deletion.

IES-0883 User Manual Page 60

802.1x

Radius Configuration

1. Radius Status: Click “Radius Status” drop-down menu from “Radius Status” drop-down list to choose “Enable” or “Disable” to globally enable or disable authentication.

2. Update Setting: Click “Update Setting” button when you finished Radius Status Setting.

Add Radius:

1. Add Radius: Click “Add Radius” button. The “Radius Server Setting” window appears.

2. Radius Server IP: Click in the “Radius Server IP” textbox and specify the IP address of the remote radius server host.

3. Radius Server Port: Click in the “Radius Server Port” textbox and specify the UDP destination port for authentication requests. The host is not used for authentication if set to 0.

4. Secret Key: Click in the “Secret Key” textbox and specify the authentication and encryption key for all radius communications between the Switch and radius server.

This key must match the encryption used on the radius daemon. All leading spaces are ignored, but spaces within and at the end of the key are used. If spaces are used in the

IES-0883 User Manual Page 61

key, do not enclose the key in quotaion marks unless the quotation marks themselves are part of the key.

5. Timeout <1-1000>: Click in the “Timeout” textbox and specify the time interval (in seconds) that the Switch waits for the radius server to reply before retransmitting.

Enter a value in the range 1 to 1000.

6. Retransmit <1-100>: Click in the “Retransmit” textbox and specify the number of times a radius request is resent to a server if that server is not responding or responding slowly. Enter a value in the range 1 to 100.

7. Sumit: Click “Sumit” button when you finished Radius Server Setting.

Delete Radius:

1. Delete Radius: Click “Delete Radius” button. The “Select Radius Server IP” window appears.

2. Select Radius Server IP: Click “Select Radius Server IP” drop-down menu from “Select

Radius Server IP” drop-down list to choose the IP address of the remote radius server host to be deleted.

3. Sumit: Click “Sumit” button when you finished radius server deletion.

IES-0883 User Manual Page 62

Port Authentication

1. Interface: Click “Interface” drop-down menu from “Interface” drop-down list to choose the port to be set port-based authentication.

2. Authentication State: Click “Authentication State” drop-down menu from

“Authentication State” drop-down list to choose “Enable” or “Disable” to enable or disable authentication state.

3. Port Control: Click “Port Control” drop-down menu from “Port Control” drop-down list to choose “Auto”, “Force Authorized”, or “Force Unauthorized” to force a port state. “Auto” specifies to enable authentication on port. “Force Authorized” specifies to force a port to always be in an authorized state. “Force Unauthorized” specifies to force a port to always be in an unauthorized state.

4. Periodic Reauthentication: Click “Periodic Reauthentication” drop-down menu from

“Periodic Reauthentication” drop-down list to choose “Enable” or “Disable” to enable or disable periodic reauthentication.

5. Reauthentication Period <1-4294967295>: Click in the “Reauthentication Period” textbox and specify the seconds between reauthorization attempts. The default time is

3600 seconds.

6. Update Setting: Click “Update Setting” button when you finished port-based authentication setting.

IES-0883 User Manual Page 63

Other Protocols

GVRP

GVRP Global Setting:

1. GVRP: Click “GVRP” drop-down menu from “GVRP” drop-down list to choose “Enable” or

“Disable” to enable or disable GVRP (GARP VLAN Registration Protocol).

2. Dynamic VLAN creation: Click “Dynamic VLAN creation” drop-down menu from

“Dynamic VLAN creation” drop-down list to choose “Enable” or “Disable” to enable or disable Dynamic VLAN creation. GARP (Generic Attribute Registration Protocol) provides IEEE802.1Q compliant VLAN pruning and dynamic VLAN creation on

IEEE802.1Q trunk ports.

3. Update Setting: Click “Update Setting” button when you finished GVRP Global Setting.

Per port setting (include LAG):

1. GVRP: Click “GVRP” drop-down menu from “GVRP” drop-down list to choose “Enable” or

“Disable” to enable or disable GVRP for the port.

2. GVRP applicant: Click “GVRP applicant” drop-down menu from “GVRP applicant” drop-down list to choose “Active” or “Normal” to the port. Ports in the GVRP active applicant state send GVRP VLAN declarations when they are in the STP (Spanning Tree

Protocol) blocking state, which prevents the STP bridge protocol data units (BPDUs) from being pruned from the other port. Ports in the GVRP normal applicant state do not declare GVRP VLANs when in the STP blocking state.

3. GVRP registration: Click “GVRP registration” drop-down menu from “GVRP registration” drop-down list to choose “Enable” or “Disable” to enable or disable GVRP registration to the port. Configuring an IEEE802.1Q trunk port in registration mode allows dynamic

IES-0883 User Manual Page 64

creation (if dynamic VLAN creation is enabled), registration, and deregistration of

VLANs on the trunk port.

4. Update Setting: Click “Update Setting” button when you finished Per port setting.

IGMP Snooping

1. IGMP mode: Click “IGMP mode” drop-down menu from “IGMP mode” drop-down list to choose “Disable”, “Passive”, or “querier” for the switch. Disable: Disable IGMP on the switch. Passive: The switch with only multicast-data-forwarding capability. Querier: The switch acts as the querier for the network. There is only one querier on a network at any time.

2. Update Setting: Click “Update Setting” button when you finished IGMP mode settings.

3. VLAN ID: Click “VLAN ID” drop-down menu from “VLAN ID” drop-down list to choose the VLAN under configuration for the switch.

4. IGMP version: Click “IGMP version” drop-down menu from “IGMP version” drop-down list to choose “1”, “2”, or “3” for the switch.

5. Fast-leave: Click “fast-leave” drop-down menu from “fast-leave” drop-down list to choose “Enable” or “Disable” for the switch. Enable this function will allow members of a multicast group to leave the group immediately when an IGMP Leave Report Packet is received by the Switch.

IGMP querier:

1. Query-interval: Click in the “query-interval” textbox and specify a new number from 1 ~

18000. The query-interval field is used to set the time (in seconds) between transmitting IGMP queries. Entries between 1 and 18000 seconds are allowed. Default

= 125.

2. Max-response-time: Click in the “max-response-time” textbox and specify a new number from 1 ~ 124. This determines the maximum amount of time in seconds allowed before sending an IGMP response report. The max-response-time field allows an entry between 1 and 124 (seconds). Default = 10.

IGMP passive snooping:

1. Report suppression: Click “report suppression” drop-down menu from “report

IES-0883 User Manual Page 65

suppression” drop-down list to choose “Enable” or “Disable” for the switch. Use this command to enable report suppression for IGMP version 1 and version 2. Report suppression does not apply to IGMP version 3, and is turned off by default for IGMP version 1 and IGMP version 2 reports. The switch uses IGMP report suppression to forward only one IGMP report per multicast router query to multicast devices. When

IGMP router suppression is enabled, the switch sends the first IGMP report from all hosts for a group to all the multicast routers. The switch does not send the remaining

IGMP reports for the group to the multicast routers. This feature prevents duplicate reports from being sent to the multicast devices.

2. Update Setting: Click “Update Setting” button when you finished IGMP Snooping.

NTP

NTP Setting:

1. NTP Status: Click “NTP Status” drop-down menu from “NTP Status” drop-down list to choose “Enable” or “Disable” to enable or disable NTP for the Switch.

2. NTP Server (IP Address or Domain name): Click in the “NTP Server” textbox and specify the IP address or Domain name of NTP server.

3. Sync Time: Click “Sync Time” button to synchronize time with NTP server.

4. Time Zone: Click “Tmie Zone” drop-down menu from “Tmie Zone” drop-down list to set time zone.

5. Polling Interval (1-10080 min): Click in the “Polling Interval” textbox and specify the polling interval.

6. Update Setting: Click “Update Setting” button when you finished NTP Setting.

Daylight Saving Setting:

1. Daylight Saving Mode: Click "Daylight Saving Mode" drop-down menu from "Daylight

Saving Mode" drop-down list to choose "Disable", "Weekday", or "Date" to choose

IES-0883 User Manual Page 66

disable, weekday, or date daylight saving for the Switch.

2. Time Set Offset (1-1440 min): Click in the "Time Set Offset" textbox and specify the offset time of daylight saving. For example enter 60 for one hour offset.

3. Daylight Saving Tmiezone: Click in the "Daylight Saving Tmiezone" textbox and specify the daylight saving timezone. This can be any given name in 14-character alpha-numericals. Enter the Daylight-Saving time zone using the following example:

EDT - East Daylight Saving Time Zone.

CDT - Central Daylight-Saving Time Zone.

MDT - Mountain Daylight-Saving Time Zone.

PDT - Pacific Daylight-Saving Time Zone.

ADT - Alaska Daylight-Saving Time Zone.

4. Weekday: Click in the textboxes and specify the daylight saving period.

· Month: Click "Month" drop-down menu from "Month" drop-down list to choose from January to December.

· Week: <1-5> Specifies weekdays from Monday to Friday.

· Day: Click "Day" drop-down menu from "Day" drop-down list to choose from

Sunday to Saturday.

· Hour: <0-23> Specifies from 0 to 23.

· Minute: <0-59> Specifies from 0 to 59.

5. Date: Click in the textboxes and specify the daylight saving period.

· Month: Click "Month" drop-down menu from "Month" drop-down list to choose from January to December.

· Day: <1-31> Specifies from 1 to 31.

· Hour: <0-23> Specifies from 0 to 23.

· Minute: <0-59> Specifies from 0 to 59.

6. Update Setting: Click "Update Setting" button when you finished Daylight Saving

Setting.

<Note> The “Week”, “Hour”, “Minute”, and “Day” fields would not accept the alphabetic characters (Like Jan, Feb, sun, mon). They only accept the two digit numbers (0 throught 9).

IES-0883 User Manual Page 67

Command Line Console Management

The switch provides a command line console interface for configuration purposes. The switch can be configured either locally through its RS-232 port or remotely via a Telnet session. For the later, you must specify an IP address for the switch first.

This chapter describes how to configure the switch using its console by Commend Line.

Administration Console

Connect the DB9 straight cable to the RS-232 serial port of the device to the RS-232 serial port of the terminal or computer running the terminal emulation application.

Direct access to the administration console is achieved by directly connecting a terminal or a PC equipped with a terminal-emulation program (such as HyperTerminal) to the switch console port.

When using the management method, configure the terminal-emulation program to use the following parameters (you can change these settings after login):

[Default parameters]

115,200bps

8 data bits

No parity

1 stop bit

Exec Mode (View Mode)

Logon to Exec Mode (View Mode)

IES-0883 User Manual Page 68

At the switch_a login: prompt just type in “root” and press <Enter> to logon to Exec Mode

(or View Mode). switch_a login: root

Basic commands

Exec Mode (or View Mode) is the base mode from where users can perform basic commands like: clear, debug, disable, enable, exit, help, logout, no, quit, show, terminal

The CLI contains a text-based help facility. Access this help by typing in the full or partial command string then typing a question mark “?”. The CLI displays the command keywords or parameters along with a short description.

At the switch_a> prompt just press <?> to list the above basic commands. switch_a>?

At the switch_a> prompt just type in the full or partial command string then typing a question mark “?” to display the command keywords or parameters along with a short description. switch_a>show ?

IES-0883 User Manual Page 69

Login timed out

The login session to Exec Mode (or View Mode) has timed out due to an extended period of inactivity (60 seconds) to indicate authentication attempt timed out. And the switch_a

login: prompt will show on the screen.

Logon back to Exec Mode (View Mode)

At the switch_a login: prompt just type in “root” and press <Enter> to logon back to Exec

Mode (or View Mode). switch_a login: root

IES-0883 User Manual Page 70

Exit from Exec Mode (View Mode)

At the switch_a> prompt just type in “exit” and press <Enter> to exit from Exec Mode (or

View Mode). switch_a>exit

Privileged Exec Mode (Enable Mode)

Logon to Privileged Exec Mode (Enable Mode)

At the switch_a> prompt just type in “enable” and press <Enter> to logon to Privileged

Exec Mode (or Enable Mode). And the switch_a# prompt will show on the screen. switch_a>enable

IES-0883 User Manual Page 71

Commands

Privileged Exec Mode (or Enable Mode) allows users to run commands as following.

At the switch_a# prompt just press <?> to list the commands. switch_a#?

At the switch_a# prompt just type in the full or partial command string then typing a

IES-0883 User Manual Page 72

question mark “?” to display the command keywords or parameters along with a short description. switch_a#show ?

Login timed out

The login session to Privileged Exec Mode (or Enable Mode) has timed out due to an extended period of inactivity (60 seconds) to indicate authentication attempt timed out.

And the switch_a login: prompt will show on the screen.

Logon back to Exec Mode (View Mode)

At the switch_a login: prompt just type in “root” and press <Enter> to logon back to Exec

Mode (or View Mode). switch_a login: root

IES-0883 User Manual Page 73

Exit from Privileged Exec Mode (or Enable Mode)

At the switch_a# prompt just type in “exit” and press <Enter> to exit from Privileged Exec

Mode (or Enable Mode). switch_a#exit

Configure Mode (Configure Terminal Mode)

Logon to Configure Mode (Configure Terminal Mode)

At the switch_a# prompt just type in “configure terminal” and press <Enter> to logon to

Configure Mode (or Configure Terminal Mode). And the switch_a(config)# prompt will show on the screen. switch_a#configure terminal

IES-0883 User Manual Page 74

Commands

Configure Mode (or Configure Terminal Mode) serves as a gateway into the modes as following.

At the switch_a(config)# prompt just press <?> to list the commands. switch_a(config)#?

IES-0883 User Manual Page 75

At the switch_a(config)# prompt just type in the full or partial command string then typing a question mark “?” to display the command keywords or parameters along with a short description. switch_a(config)#show ?

Login timed out

The login session to Configure Mode (or Configure Terminal Mode) has timed out due to an extended period of inactivity (60 seconds) to indicate authentication attempt timed out.

And the switch_a login: prompt will show on the screen.

Logon back to Exec Mode (View Mode)

At the switch_a login: prompt just type in “root” and press <Enter> to logon back to Exec

Mode (or View Mode). switch_a login: root

Exit from Configure Mode (or Configure Terminal Mode)

At the switch_a(config)# prompt just type in “exit” and press <Enter> to exit from

Configure Mode (or Configure Terminal Mode). switch_a(config)#exit

IES-0883 User Manual Page 76

System

System Information, System Name/Password, IP Address, Save Configuration,

Firmware Upgrade, Reboot, Logout

System Name/Password

System Name:

1. Command Mode: Configure mode

Logon to Configure Mode (Configure Terminal Mode).

The switch_a(config)# prompt will show on the screen. switch_a(config)#

2. Usage:

Use hostname command to set or change the network server name.

Use the no hostname command to disable this function.

3. Command Syntax:

(no) hostname HOSTNAME

HOSTNAME specifies the network name of the system.

4. Example:

The following example sets the hostname to switch, and shows the change in the prompt: switch_a(config)#hostname switch switch(config)#

Password:

1. Command Mode: Configure mode

Logon to Configure Mode (Configure Terminal Mode).

The switch_a(config)# prompt will show on the screen.

IES-0883 User Manual Page 77

switch_a(config)#

2. Usage:

Use enable password command to modify or create a password to be used when entering the Enable mode.

3. Command Syntax: enable password PASSWORD

PASSWORD specifies the new password of the system.

4. Example:

The following example sets the new password mypasswd to switch: switch_a(config)#enable password mypasswd switch_a(config)#

IES-0883 User Manual Page 78

IP Address

IP Address/IP Subnet Mask:

1. Command Mode: Interface mode

Logon to Configure Mode (Configure Terminal Mode).

Then logon to Interface mode. vlan1.1 means vlan 1.

The switch_a(config-if)# prompt will show on the screen. switch_a(config)#interface vlan1.1 switch_a(config-if)#

2. Usage:

Use ip address command to set the IP address of an interface.

Use the no ip address command to remove the IP address from an interface.

3. Command Syntax: ip address IP-ADDRESS no ip address IP-ADDRESS no ip address

IP-ADDRESS A.B.C.D/M specifies the IP address and prefix length of an interface.

M specifies IP subnet mask, 8: 255.0.0.0, 16:255.255.0.0, 24: 255.255.255.0.

4. Example:

The following example sets the new IP address 192.168.1.10 and new IP subnet mask

255.255.255.0 to switch: switch_a(config)#interface vlan1.1 switch_a(config-if)#ip address 192.168.1.10/24 switch_a(config-if)#

Default Gateway:

1. Command Mode: Configure mode

Logon to Configure Mode (Configure Terminal Mode).

The switch_a(config)# prompt will show on the screen. switch_a(config)#

2. Usage:

Use ip default-gateway command to set the IP address of the default gateway.

Use the no ip default-gateway command to remove the IP address of the default gateway.

3. Command Syntax: ip default-gateway IP-ADDRESS no ip default-gateway

IP-ADDRESS A.B.C.D specifies the IP address of the default gateway.

4. Example:

IES-0883 User Manual Page 79

The following example sets the default gateway 192.168.1.254 to switch: switch_a(config)#ip default-gateway 192.168.1.254 switch_a(config)#

DNS Server:

1. Command Mode: Configure mode

Logon to Configure Mode (Configure Terminal Mode).

The switch_a(config)# prompt will show on the screen. switch_a(config)#

2. Usage:

Use ip dns command to set the IP address of the DNS server.

Use the no ip dns command to remove the IP address of the DNS server.

3. Command Syntax: ip dns IP-ADDRESS no ip dns

IP-ADDRESS A.B.C.D specifies the IP address of the DNS server.

4. Example:

The following example sets the DNS server 192.168.1.100 to switch: switch_a(config)#ip dns 192.168.1.100 switch_a(config)#

Save Configuration

Load config from TFTP server:

1. Command Mode: Privileged Exec mode

Logon to Privileged Exec Mode (Enable Mode).

The switch_a# prompt will show on the screen. switch_a#

2. Usage:

Use install image command to load configuration file from tftp server to switch.

3. Command Syntax: install image IP-ADDRESS WORD

IP-ADDRESS specifies the IP address of tftp server.

WORD specifies the file name to be loaded to switch.

4. Example:

The following example specifies upgrading firmware (file name: flash.tgz) from tftp server

(IP address: 192.168.1.100) to switch: switch_a#install image 192.168.1.100 flash.tgz

IES-0883 User Manual Page 80

switch_a#

Load config to TFTP server:

1. Command Mode: Privileged Exec mode

Logon to Privileged Exec Mode (Enable Mode).

The switch_a# prompt will show on the screen. switch_a#

2. Usage:

Use write config-file command to backup configuration file to tftp server.

3. Command Syntax: write config-file IP-ADDRESS

IP-ADDRESS specifies the IP address of tftp server.

4. Example:

The following example backups configuration file to tftp server (IP address: 192.168.1.20): switch_a#write config-file 192.168.1.20 switch_a#

Save Configuration:

1. Command Mode: Privileged Exec mode

Logon to Privileged Exec Mode (Enable Mode).

The switch_a# prompt will show on the screen. switch_a#

2. Usage:

Use copy running-config startup-config command to write configurations to the file to be used at startup. This is the same as the write memory command.

3. Command Syntax: copy running-config startup-config

4. Example:

The following example specifies writing configurations to the file to be used at startup to switch: switch_a#copy running-config startup-config switch_a#

Restore Default:

1. Command Mode: Privileged Exec mode

IES-0883 User Manual Page 81

Logon to Privileged Exec Mode (Enable Mode).

The switch_a# prompt will show on the screen. switch_a#

2. Usage:

Use restore default command to restore default setting of the switch.

3. Command Syntax: restore default

4. Example:

The following example restores default setting of the switch: switch_a#restore default switch_a#

Auto Save:

1. Command Mode: Configure mode

Logon to Configure Mode (Configure Terminal Mode).

The switch_a(config)# prompt will show on the screen. switch_a(config)#

2. Usage:

Use this command to enable auto save configuration function. The configuration will be automatically saved at every configured interval while this command is enabled. Use the no form of this command to disable this feature.

3. Command Syntax: service auto-config enable no service auto-config enable

4. Example:

The following example enables or disables auto save configuration to switch: switch_a(config)#service auto-config enable switch_a(config)#no service auto-config enable switch_a(config)#

Auto Save Interval (5~65536 sec):

1. Command Mode: Configure mode

Logon to Configure Mode (Configure Terminal Mode).

The switch_a(config)# prompt will show on the screen. switch_a(config)#

2. Usage:

IES-0883 User Manual Page 82

Use this command to set the interval when the configuration would be automatically saved. The range of interval value is from 5 to 65535. And the default value is 30 seconds.

3. Command Syntax: service auto-config interval WORD

WORD specifies the interval value.

4. Example:

The following example sets the interval WORD (10) when the configuration would be automatically saved to switch: switch_a(config)#service auto-config interval 10 switch_a(config)#

Firmware Upgrade

1. Command Mode: Privileged Exec mode

Logon to Privileged Exec Mode (Enable Mode).

The switch_a# prompt will show on the screen. switch_a#

2. Usage:

Use install image command to upgrade firmware from tftp server to switch.

3. Command Syntax: install image IP-ADDRESS WORD

IP-ADDRESS specifies the IP address of tftp server.

WORD specifies the file name to be upgraded to switch.

4. Example:

The following example specifies upgrading firmware (file name: flash.tgz) from tftp server

(IP address: 192.168.1.100) to switch: switch_a#install image 192.168.1.100 flash.tgz switch_a#

Please follow the message on the screen during the firmware upgrade process. Do not turn off the power or perform other functions during this period of time.

IES-0883 User Manual Page 83

At the “switch_a# prompt just type in “reload” and press <Enter> to reboot the switch after completing the upgrade process.

Reboot

1. Command Mode: Privileged Exec mode

Logon to Privileged Exec Mode (Enable Mode).

The switch_a# prompt will show on the screen. switch_a#

2. Usage:

Use reload command to restart switch.

3. Command Syntax: reload

4. Example:

The following example specifies restarting switch:

IES-0883 User Manual Page 84

switch_a#reload switch_a login:

Logout

1. Command Mode: Exec mode or Privileged Exec mode

Logon to Exec Mode (View Mode) or Privileged Exec Mode (Enable Mode).

The switch_a> or switch_a# prompt will show on the screen. switch_a> switch_a#

2. Usage:

Use logout command to exit from the Exec mode or Privileged Exec mode.

3. Command Syntax: logout

4. Example:

The following example specifies to exit from the Exec mode or Privileged Exec mode. switch_a>logout switch_a login:

IES-0883 User Manual Page 85

Port

Configuration, Port Status, Rate Control, RMON Statistics, Per Port Vlan

Activities

Configuration

Admin Setting:

1. Command Mode: Interface mode

Logon to Configure Mode (Configure Terminal Mode).

Then logon to Interface mode. fe1 means port 1.

The switch_a(config-if)# prompt will show on the screen. switch_a(config)#interface fe1 switch_a(config-if)#

2. Usage:

Use the shutdown command to shut down the selected interface.

Use the no shutdown to disable this function.

3. Command Syntax:

(no) shutdown

4. Example:

The following example shows the use of the shutdown command to shut down the interface fe1 (port 1): switch_a(config)#interface fe1 switch_a(config-if)#shutdown switch_a(config-if)#

Duplex:

1. Command Mode: Interface mode

Logon to Configure Mode (Configure Terminal Mode).

Then logon to Interface mode. fe1 means port 1.

The switch_a(config-if)# prompt will show on the screen. switch_a(config)#interface fe1 switch_a(config-if)#

2. Usage:

Use duplex command to specify the duplex mode to be used for each interface.

Use the no duplex to disable this function.

3. Command Syntax:

(no) duplex MODE

IES-0883 User Manual Page 86

MODE specifies the duplex mode: auto, full, half.

4. Example:

The following example shows the use of duplex MODE (full) to the interface fe1 (port 1): switch_a(config)#interface fe1 switch_a(config-if)#duplex full switch_a(config-if)#

Flow control:

1. Command Mode: Interface mode

Logon to Configure Mode (Configure Terminal Mode).

Then logon to Interface mode. fe1 means port 1.

The switch_a(config-if)# prompt will show on the screen. switch_a(config)#interface fe1 switch_a(config-if)#

2. Usage:

Use flowcontrol on command to enable flow control, and configure the flow control mode for the port.

Use the no flowcontrol to disable this function.

3. Command Syntax: flowcontrol on no flowcontrol

4. Example:

The following example shows the use of flowcontrol on to the interface fe1 (port 1): switch_a(config)#interface fe1 switch_a(config-if)#flowcontrol on switch_a(config-if)#

Port Status

1. Command Mode: Exec mode or Privileged Exec mode

Logon to Exec Mode (View Mode) or Privileged Exec Mode (Enable Mode).

The switch_a> or switch_a# prompt will show on the screen. switch_a> switch_a#

2. Usage:

Use the show interface command to display interface configuration and status.

IES-0883 User Manual Page 87

3. Command Syntax: show interface IFNAME

IFNAME specifies the name of the interface for which status and configuration information is desired.

4. Example:

The following example shows the use of show interface to display interface configuration and status of the interface fe1 (port 1): switch_a>show interface fe1

Rate Control

1. Command Mode: Interface mode

Logon to Configure Mode (Configure Terminal Mode).

Then logon to Interface mode. fe1 means port 1.

The switch_a(config-if)# prompt will show on the screen. switch_a(config)#interface fe1 switch_a(config-if)#

2. Usage:

Use this command to specify the ingress/egress rate to be used for each interface. The bandwidth value is in bits.

Use the no parameter with this command to remove the ingress/egress rate to be used for each interface.

3. Command Syntax:

(no) rate-control ingress/egress VALUE

VALUE

<1-10000000000 bits> (usable units: k, m, g)

<1-999>k|m for 1 to 999 kilo bits or mega bits.

1g for 1 giga bits.

4. Example:

The following example shows the use of rate-control ingress VALUE (10 mega bits) to the interface fe1 (port 1): switch_a(config)#interface fe1 switch_a(config-if)#rate-control ingress 10m switch_a(config-if)#

RMON Statistics

1. Command Mode: Exec mode or Privileged Exec mode

Logon to Exec Mode (View Mode) or Privileged Exec Mode (Enable Mode).

The switch_a> or switch_a# prompt will show on the screen.

IES-0883 User Manual Page 88

switch_a> switch_a#

2. Usage:

Use the show interface statistics command to display RMON statistics of interface.

3. Command Syntax: show interface statistics IFNAME

IFNAME specifies the name of the interface for which RMON statistics is desired.

4. Example:

The following example shows the use of show interface statistics to display RMON statistics of the interface fe1 (port 1): switch_a>show interface statistics fe1

Per Port Vlan Activities

1. Command Mode: Exec mode or Privileged Exec mode

Logon to Exec Mode (View Mode) or Privileged Exec Mode (Enable Mode).

The switch_a> or switch_a# prompt will show on the screen. switch_a> switch_a#

2. Usage:

Use show vlan command to display information about a particular VLAN by specifying the

VLAN ID.

3. Command Syntax: show vlan <2-4094>

<2-4094> VLAN ID.

4. Example:

The following is an output of show vlan command displaying information about VLAN 2: switch_a>show vlan 2

IES-0883 User Manual Page 89

Switching

Bridging, Static MAC Entry, Port Mirroring

Bridging

Aging Time (seconds):

1. Command Mode: Configure mode

Logon to Configure Mode (Configure Terminal Mode).

The switch_a(config)# prompt will show on the screen. switch_a(config)#

2. Usage:

Use this command to specify an ageing-out time for a learned MAC address. The learned

MAC address will persist till this specified time.

3. Command Syntax:

Bridge GROUP ageing-time AGEINGTIME no bridge GROUP ageing-time

Group = <1-1> The ID of the bridge-group that this ageing time is for.

AGEINGTIME = <10-1000000> The number of seconds of persistence.

4. Example:

The following example sets the new AGEINGTIME (1000) to bridge GROUP (1): switch_a(config)#bridge 1 ageing-time 1000 switch_a(config)#

Threshold level (0-100):

1. Command Mode: Interface mode

Logon to Configure Mode (Configure Terminal Mode).

Then logon to Interface mode. fe1 means port 1.

The switch_a(config-if)# prompt will show on the screen. switch_a(config)#interface fe1 switch_a(config-if)#

2. Usage:

Use storm-control level command to specify the rising threshold level for broadcasting, multicast, or destination lookup failure traffic. The storm control action occurs when traffic utilization reaches this level.

3. Command Syntax: storm-control level LEVEL

LEVEL <0-100> specifies the percentage of the threshold; percentage of the maximum speed (pps) of the interface.

IES-0883 User Manual Page 90

4. Example:

The following example shows setting storm-control level LEVEL (30) to the interface fe1

(port 1): switch_a(config)#interface fe1 switch_a(config-if)#storm-control level 30 switch_a(config-if)#

Broadcast:

1. Command Mode: Interface mode

Logon to Configure Mode (Configure Terminal Mode).

Then logon to Interface mode. fe1 means port 1.

The switch_a(config-if)# prompt will show on the screen. switch_a(config)#interface fe1 switch_a(config-if)#

2. Usage:

Use storm-control broadcast enable command to enable broadcast traffic.

Use no storm-control broadcast command to disable broadcast traffic.

3. Command Syntax: storm-control broadcast enable no storm-control broadcast

4. Example:

The following example shows setting storm-control broadcast enable to the interface fe1 (port 1): switch_a(config)#interface fe1 switch_a(config-if)#storm-control broadcast enable switch_a(config-if)#

Multicast:

1. Command Mode: Interface mode

Logon to Configure Mode (Configure Terminal Mode).

Then logon to Interface mode. fe1 means port 1.

The switch_a(config-if)# prompt will show on the screen. switch_a(config)#interface fe1 switch_a(config-if)#

2. Usage:

Use storm-control multicast enable command to enable multicast traffic.

IES-0883 User Manual Page 91

Use no storm-control multicast command to disable multicast traffic.

3. Command Syntax: storm-control multicast enable no storm-control multicast

4. Example:

The following example shows setting storm-control multicast enable to the interface fe1

(port 1): switch_a(config)#interface fe1 switch_a(config-if)#storm-control multicast enable switch_a(config-if)#

DLF:

1. Command Mode: Interface mode

Logon to Configure Mode (Configure Terminal Mode).

Then logon to Interface mode. fe1 means port 1.

The switch_a(config-if)# prompt will show on the screen. switch_a(config)#interface fe1 switch_a(config-if)#

2. Usage:

Use storm-control dlf enable command to enable destination lookup failure traffic.

Use no storm-control dlf command to disable destination lookup failure traffic.

3. Command Syntax: storm-control dlf enable no storm-control dlf

dlf destination lookup failure

4. Example:

The following example shows setting storm-control dlf enable to the interface fe1 (port

1): switch_a(config)#interface fe1 switch_a(config-if)#storm-control dlf enable switch_a(config-if)#

Static MAC Entry

Static-MAC-Entry Forward:

1. Command Mode: Configure mode

Logon to Configure Mode (Configure Terminal Mode).

The switch_a(config)# prompt will show on the screen.

IES-0883 User Manual Page 92

switch_a(config)#

2. Usage:

Use this command to statically configure a bridge entry to forward matching frames.

3. Command Syntax: bridge GROUP address MAC forward IFNAME VLANID no bridge GROUP address MAC forward IFNAME VLANID

GROUP <1-1> Bridge-group ID used for bridging.

MAC the Media Access Control (MAC) address in the HHHH.HHHH.HHHH format.

IFNAME the interface on which the frame comes in.

VLANID The VID of the VLAN that will be enabled or disabled on the bridge <2-4094>.

4. Example:

The following example configures a bridge GROUP (1) to forward matching frames (MAC address 2222.2222.2222) to the interface fe1 (port 1) in vlan VLANID (2): switch_a(config)#bridge 1 address 2222.2222.2222 forward fe1 vlan 2 switch_a(config)#

Static-MAC-Entry Discard:

1. Command Mode: Configure mode

Logon to Configure Mode (Configure Terminal Mode).

The switch_a(config)# prompt will show on the screen. switch_a(config)#

2. Usage:

Use this command to statically configure a bridge entry to discard matching frames in a particular VLAN.

3. Command Syntax: bridge GROUP address MAC discard vlan VLANID no bridge GROUP address MAC discard vlan VLANID

GROUP <1-1> Bridge-group ID used for bridging.

MAC the Media Access Control (MAC) address in the HHHH.HHHH.HHHH format.

VLANID The VID of the VLAN on the bridge <1-4094>.

4. Example:

The following example configures a bridge GROUP (1) to discard matching frames (MAC address 2222.2222.2222) in vlan VLANID (1): switch_a(config)#bridge 1 address 2222.2222.2222 discard vlan 1 switch_a(config)#

IES-0883 User Manual Page 93

Port Mirroring

1. Command Mode: Interface mode

Logon to Configure Mode (Configure Terminal Mode).

Then logon to Interface mode. fe1 means port 1.

The switch_a(config-if)# prompt will show on the screen. switch_a(config)#interface fe1 switch_a(config-if)#

2. Usage:

Use this command to define a mirror source port and its direction.

Use the no parameter with this command to disable port mirroring by the destination port on the specified source port.

3. Command Syntax: mirror interface SOURCEPORT direction SNOOPDIRECTION no mirror interface SOURCEPORT

SOURCEPORT Name of the Source interface to be used.

SNOOPDIRECTION [both|receive|transmit] both Specifies mirroring of traffic in both directions. receive Specifies mirroring of received traffic. transmit Specifies mirroring of transmitted traffic.

4. Example:

The following example enables port mirroring by the destination port fe1 (port 1) on the specified source port fe2 (port 2): switch_a(config)#interface fe1 switch_a(config-if)#mirror interface fe2 direction both switch_a(config-if)#

IES-0883 User Manual Page 94

Trunking

Port Trunking

Port Trunking

1. Command Mode: Interface mode

Logon to Configure Mode (Configure Terminal Mode).

Then logon to Interface mode. fe1 means port 1.

The switch_a(config-if)# prompt will show on the screen. switch_a(config)#interface fe1 switch_a(config-if)#

2. Usage:

Use static-channel-group command to create a static aggregator, or add a member port to an already-existing static aggregator.

Use the no static-channel-group command to detach the port from the static aggregator.

3. Command Syntax: static-channel-group <1-3> no static-channel-group

<1-3> Channel group number.

Maximum 4 ports in static-channel-group 1 and static-channel-group 2.

Maximum 2 ports in static-channel-group 3

4. Example:

The following example adding the interface fe1 (port 1) to static-channel-group 1: switch_a(config)#interface fe1 switch_a(config-if)#static-channel-group 1 switch_a(config-if)#

IES-0883 User Manual Page 95

STP / Ring

Global Configuration, RSTP Port Setting, MSTP Properties, MSTP Instance

Setting, MSTP Port Setting, Ring Setting

Global Configuration

STP Version:

1. Command Mode: Configure mode

Logon to Configure Mode (Configure Terminal Mode).

The switch_a(config)# prompt will show on the screen. switch_a(config)#

2. Usage:

Use this command to choose the Spanning Tree protocol, Rapid Spanning Tree protocol, or Multiple Spanning Tree protocol on a bridge.

3. Command Syntax: bridge GROUP protocol PROTOCOL vlan-bridge

GROUP <1-1> Bridge group name used for bridging.

PROTOCOL

ieee IEEE 802.1Q spanning-tree protocol.

mstp IEEE 802.1s multiple spanning-tree protocol. rstp IEEE 802.1w rapid spanning-tree protocol.

4. Example:

The following example chooses the PROTOCOL (rstp) on bridge GROUP (1): switch_a(config)#bridge 1 protocol rstp vlan-bridge switch_a(config)#

Multiple Spanning Tree Protocol:

1. Command Mode: Configure mode

Logon to Configure Mode (Configure Terminal Mode).

The switch_a(config)# prompt will show on the screen. switch_a(config)#

2. Usage:

Use this command to enable the Multiple Spanning Tree protocol on a bridge.

Use the no form of the command to disable the Multiple Spanning Tree protocol on a bridge.

3. Command Syntax: bridge GROUP multiple-spanning-tree enable no bridge GROUP multiple-spanning-tree enable BRIDGE-FORWARD

GROUP <1-1> Bridge group name used for bridging.

IES-0883 User Manual Page 96

BRIDGE-FORWARD Puts all ports of the specified bridge into the forwarding state.

4. Example:

The following example enables or disables the multiple-spanning-tree on bridge GROUP

(1): switch_a(config)#bridge 1 multiple-spanning-tree enable switch_a(config)#no bridge 1 multiple-spanning-tree enable bridge-forward switch_a(config)#

Rapid Spanning Tree Protocol:

1. Command Mode: Configure mode

Logon to Configure Mode (Configure Terminal Mode).

The switch_a(config)# prompt will show on the screen. switch_a(config)#

2. Usage:

Use this command to enable the Rapid Spanning Tree protocol on a bridge.

Use the no form of the command to disable the Rapid Spanning Tree protocol on a bridge.

3. Command Syntax: bridge GROUP rapid-spanning-tree enable no bridge GROUP rapid-spanning-tree enable BRIDGE-FORWARD

GROUP <1-1> Bridge group name used for bridging.

BRIDGE-FORWARD Puts all ports of the specified bridge into the forwarding state.

4. Example:

The following example enables or disables the rapid-spanning-tree on bridge GROUP (1): switch_a(config)#bridge 1 rapid-spanning-tree enable switch_a(config)#no bridge 1 rapid-spanning-tree enable bridge-forward switch_a(config)#

Spanning Tree Protocol:

5. Command Mode: Configure mode

Logon to Configure Mode (Configure Terminal Mode).

The switch_a(config)# prompt will show on the screen. switch_a(config)#

6. Usage:

Use this command to enable the Spanning Tree protocol on a bridge.

Use the no form of the command to disable the Spanning Tree protocol on a bridge.

7. Command Syntax: bridge GROUP spanning-tree enable no bridge GROUP spanning-tree enable BRIDGE-FORWARD

GROUP <1-1> Bridge group name used for bridging.

IES-0883 User Manual Page 97

BRIDGE-FORWARD Puts all ports of the specified bridge into the forwarding state.

8. Example:

The following example enables or disables the spanning-tree on bridge GROUP (1): switch_a(config)#bridge 1 spanning-tree enable switch_a(config)#no bridge 1 spanning-tree enable bridge-forward switch_a(config)#

Bridge Priority (0..61440):

1. Command Mode: Configure mode

Logon to Configure Mode (Configure Terminal Mode).

The switch_a(config)# prompt will show on the screen. switch_a(config)#

2. Usage:

Use this command to set bridge priority for the common instance. Using a lower priority indicates a greater likelihood of the bridge becoming root.

3. Command Syntax: bridge GROUP priority PRIORITY no bridge GROUP priority

GROUP <1-1> The ID of the bridge group for which the priority is set.

PRIORITY <0-61440> The bridge priority.

4. Example:

The following example sets the priority PRIORITY (4096) of bridge GROUP (1): switch_a(config)#bridge 1 priority 4096 switch_a(config)#

Hello Time (sec) (1..9):

1. Command Mode: Configure mode

Logon to Configure Mode (Configure Terminal Mode).

The switch_a(config)# prompt will show on the screen. switch_a(config)#

2. Usage:

Use this command to set the hello-time, the time in seconds after which (if this bridge is the root bridge) all the bridges in a bridged LAN exchange Bridge Protocol Data Units

(BPDUs).

3. Command Syntax: bridge GROUP hello-time HELLOTIME no bridge GROUP hello-time

IES-0883 User Manual Page 98

GROUP <1-1> The ID of the bridge group to which this hello time is assigned.

HELLOTIME <1-9> The hello BPDU interval in seconds.

4. Example:

The following example sets the hello-time HELLOTIME (9) of bridge GROUP (1): switch_a(config)#bridge 1 hello-time 9 switch_a(config)#

Max Age (sec) (6..28):

1. Command Mode: Configure mode

Logon to Configure Mode (Configure Terminal Mode).

The switch_a(config)# prompt will show on the screen. switch_a(config)#

2. Usage:

Use this command to set the max-age for a bridge.

Use the no parameter with this command to restore the default value of max-age.

3. Command Syntax: bridge GROUP max-age MAXAGE no bridge GROUP max-age

GROUP <1-1> The ID of the bridge group to which this maximum age time is assigned.

MAXAGE <6-28> The maximum time, in seconds, to listen for the root bridge.

4. Example:

The following example sets the max-age MAXAGE (28) of bridge GROUP (1): switch_a(config)#bridge 1 max-age 28 switch_a(config)#

Forward Delay (sec) (4..30):

1. Command Mode: Configure mode

Logon to Configure Mode (Configure Terminal Mode).

The switch_a(config)# prompt will show on the screen. switch_a(config)#

2. Usage:

Use this command to set the time (in seconds) after which (if this bridge is the root bridge) each port changes states to learning and forwarding.

Use the no parameter with this command to restore the default value.

3. Command Syntax: bridge GROUP forward-time FORWARD_DELAY no bridge GROUP forward-time

IES-0883 User Manual Page 99

GROUP <1-1> The ID of the bridge group to which this delay time is assigned.

FORWARD_DELAY <4-30> the forwarding time delay in seconds.

4. Example:

The following example sets the forward-time FORWARD_DELAY (30) of bridge GROUP

(1): switch_a(config)#bridge 1 forward-time 30 switch_a(config)#

RSTP Port Setting

Priority(Granularity 16):

1. Command Mode: Interface mode

Logon to Configure Mode (Configure Terminal Mode).

Then logon to Interface mode. fe1 means port 1.

The switch_a(config-if)# prompt will show on the screen. switch_a(config)#interface fe1 switch_a(config-if)#

2. Usage:

Use this command to set the port priority for a bridge. The lower priority indicates a greater likelihood of the bridge becoming root.

3. Command Syntax: bridge GROUP priority PRIORITY

GROUP <1-1> the ID of the bridge group.

PRIORITY <0-240> The priority to be assigned to the group.

4. Example:

The following example sets the priority PRIORITY (100) of the interface fe1 (port 1) of bridge GROUP (1): switch_a(config)#interface fe1 switch_a(config-if)#bridge 1 priority 100 switch_a(config-if)#

Admin. Path Cost:

1. Command Mode: Interface mode

Logon to Configure Mode (Configure Terminal Mode).

Then logon to Interface mode. fe1 means port 1.

The switch_a(config-if)# prompt will show on the screen. switch_a(config)#interface fe1 switch_a(config-if)#

IES-0883 User Manual Page 100

2. Usage:

Use this command to set the cost of a path associated with a bridge-group.

Use the no parameter with this command to restore the default cost of a path associated with a bridge-group.

3. Command Syntax: bridge GROUP path-cost PATHCOST no bridge GROUP path-cost

GROUP <1-1> the ID of the bridge group.

PATHCOST <1-200000000> The cost to be assigned to the group.

4. Example:

The following example sets the cost (123) of the interface fe1 (port 1) of bridge GROUP (1): switch_a(config)#interface fe1 switch_a(config-if)#bridge 1 path-cost 123 switch_a(config-if)#

Point to Point Link:

1. Command Mode: Interface mode

Logon to Configure Mode (Configure Terminal Mode).

Then logon to Interface mode. fe1 means port 1.

The switch_a(config-if)# prompt will show on the screen. switch_a(config)#interface fe1 switch_a(config-if)#

2. Usage:

Use spanning-tree link-type command to set the link type of a port to enable or disable rapid transition.

Use the no spanning-tree link-type command to set a port to its default state and to disable rapid transition.

3. Command Syntax:

(no) spanning-tree link-type LINKTYPE

LINKTYPE The link type to be assigned to the port.

point-to-point Enable rapid transition.

shared Disable rapid transition.

4. Example:

The following example sets the link-type LINKTYPE (point-to-point) of the interface fe1

(port 1): switch_a(config)#interface fe1 switch_a(config-if)#spanning-tree link-type point-to-point switch_a(config-if)#

IES-0883 User Manual Page 101

Autoedge:

1. Command Mode: Interface mode

Logon to Configure Mode (Configure Terminal Mode).

Then logon to Interface mode. fe1 means port 1.

The switch_a(config-if)# prompt will show on the screen. switch_a(config)#interface fe1 switch_a(config-if)#

2. Usage:

Use spanning-tree autoedge command to assist in automatic identification of the edge port.

Use the no spanning-tree autoedge command to disable this feature.

3. Command Syntax:

(no) spanning-tree autoedge

4. Example:

The following example enables the spanning-tree autoedge of the interface fe1 (port 1): switch_a(config)#interface fe1 switch_a(config-if)#spanning-tree autoedge switch_a(config-if)#

Edgeport:

1. Command Mode: Interface mode

Logon to Configure Mode (Configure Terminal Mode).

Then logon to Interface mode. fe1 means port 1.

The switch_a(config-if)# prompt will show on the screen. switch_a(config)#interface fe1 switch_a(config-if)#

2. Usage:

Use spanning-tree edgeport command to set a port as an edge-port and to enable rapid transitions.

Use the no spanning-tree edgeport command to set a port to its default state (not an edge-port) and to disable rapid transitions.

3. Command Syntax:

(no) spanning-tree edgeport

4. Example:

The following example enables the spanning-tree edgeport of the interface fe1 (port 1):

IES-0883 User Manual Page 102

switch_a(config)#interface fe1 switch_a(config-if)#spanning-tree edgeport switch_a(config-if)#

MSTP Properties

Region Name:

1. Command Mode: MST Configuration mode

Logon to Configure Mode (Configure Terminal Mode).

Then logon to MST Configuration mode.

The switch_a(config-mst)# prompt will show on the screen. switch_a(config)#spanning-tree mst configuration switch_a(config-mst)#

2. Usage:

Use this command to create an MST region and specify a name to it. MST bridges of a region form different spanning trees for different VLANs. By default, each MST bridge starts with the region name as its bridge address. This means each MST bridge is a region by itself, unless specifically added to one.

3. Command Syntax: bridge GROUP region REGION_NAME no bridge GROUP region

GROUP <1-1> Specify the bridge-group ID.

REGION_NAME Specify the name of the region.

4. Example:

The following example creates an MST region and specifies a name (regionname) to it in bridge GROUP (1):

Switch_a(config)#spanning-tree mst configuration switch_a(config-mst)#bridge 1 region regionname switch_a(config-mst)#

Revision Level:

1. Command Mode: MST Configuration mode

Logon to Configure Mode (Configure Terminal Mode).

Then logon to MST Configuration mode.

The switch_a(config-mst)# prompt will show on the screen. switch_a(config)#spanning-tree mst configuration switch_a(config-mst)#

2. Usage:

Use this command to specify the number for configuration information. The default value of revision number is 0.

IES-0883 User Manual Page 103

3. Command Syntax: bridge GROUP revision REVISION_NUM

GROUP <1-1> Specify the bridge-group ID.

REVISION_NUM <0-255> Revision number.

4. Example:

The following example specifies a revision number (25) of MST configuration in bridge

GROUP (1): switch_a(config)#spanning-tree mst configuration switch_a(config-mst)#bridge 1 revision 25 switch_a(config-mst)#

Max Hops:

1. Command Mode: Configure mode

Logon to Configure Mode (Configure Terminal Mode).

The switch_a(config)# prompt will show on the screen. switch_a(config)#

2. Usage:

Use this command to specify the maximum allowed hops for BPDU in an MST region. This parameter is used by all the instances of the MST. Specifying the max hops for a BPDU prevents the messages from looping indefinetely in the network. When a bridge receives a

MST BPDU that has exceeded the allowed max-hops, it discards the BPDU.

3. Command Syntax: bridge GROUP max-hops HOP_COUNT no bridge GROUP max-hops

GROUP <1-1> Specify the bridge-group ID.

HOP_COUNT Maximum hops the BPDU will be valid for.

4. Example:

The following example specifies the maximum allowed hops (25) for BPDU in bridge

GROUP (1): switch_a(config)#bridge 1 max-hops 25 switch_a(config)#

MSTP Instance Setting

Bridge Instance VLAN:

1. Command Mode: MST Configuration mode

Logon to Configure Mode (Configure Terminal Mode).

Then logon to MST Configuration mode.

The switch_a(config-mst)# prompt will show on the screen.

IES-0883 User Manual Page 104

switch_a(config)#spanning-tree mst configuration switch_a(config-mst)#

2. Usage:

Use this command to simultaneously add multiple VLANs for the corresponding instance of a b ridge. This command can be used only after the VLANs are defined. Use the no parameter with this command to simultaneously remove multiple VLANs for the corresponding instance of a bridge.

3. Command Syntax: bridge GROUP instance INSTANCE_ID vlan VLAN_ID no bridge GROUP instance INSTANCE_ID vlan VLAN_ID

GROUP <1-1> Specify the bridge-group ID.

INSTANCE_ID <1-15> Specify the instance ID.

VLAN_ID <1-4094> Specify multiple VLAN IDs corresponding to the bridge instance

4. Example:

The following example associates multiple VLANs (10) and (20) to instance (1) of bridge

GROUP (1): switch_a(config)#bridge 1 protocol mstp switch_a(config)#spanning-tree mst configuration switch_a(config-mst)#bridge 1 instance 1 vlan 10, 20 switch_a(config-mst)#

Bridge Instance Priority:

1. Command Mode: Configure mode

Logon to Configure Mode (Configure Terminal Mode).

The switch_a(config)# prompt will show on the screen. switch_a(config)#

2. Usage:

Use this command to set the bridge priority for an MST instance to the value specified. Use the no parameter with this command to restore the default value of the bridge priority.

The lower the priority of the bridge, the better the chances are the bridge becoming a root bridge or a designated bridge for the LAN. The priority values can be set only in increments of 4096.

3. Command Syntax: bridge GROUP instance INSTANCE_ID priority BRIDGE_PRIORITY no bridge GROUP instance INSTANCE_ID priority

GROUP <1-1> Specify the bridge-group ID.

INSTANCE_ID Specify the instance ID.

BRIDGE_PRIORITY <0-61440> Specify the bridge priority.

4. Example:

The following example sets the bridge priority (0) for an MST instance (3) in bridge GROUP

IES-0883 User Manual Page 105

(1): switch_a(config)#bridge 1 instance 3 priority 0 switch_a(config)#

MSTP Port Setting

Bridge-Group Instance:

1. Command Mode: Interface mode

Logon to Configure Mode (Configure Terminal Mode).

Then logon to Interface mode. fe1 means port 1.

The switch_a(config-if)# prompt will show on the screen. switch_a(config)#interface fe1 switch_a(config-if)#

2. Usage:

Use this command to assign a Multiple Spanning Tree instance to a port. Use the no parameter with this command to remove the instance.

3. Command Syntax: bridge GROUP instance INSTANCE_ID no bridge GROUP instance INSTANCE_ID

GROUP <1-1> Specify the bridge-group ID.

INSTANCE_ID Specify the instance ID.

4. Example:

The following example assigns a Multiple Spanning Tree instance (3) to a port (fe1) in bridge GROUP (1): switch_a(config)#interface fe1 switch_a(config-if)#bridge-group 1 instance 3 switch_a(config-if)#

Bridge-Group Instance Priority:

1. Command Mode: Interface mode

Logon to Configure Mode (Configure Terminal Mode).

Then logon to Interface mode. fe1 means port 1.

The switch_a(config-if)# prompt will show on the screen. switch_a(config)#interface fe1 switch_a(config-if)#

2. Usage:

Use this command to set the port priority for a bridge group. The Multiple Spanning Tree

Protocol uses port priority as a tiebreaker to determine which port should forward frames

IES-0883 User Manual Page 106

for a particular instance on a LAN, or which port should be the root port for an instance. A lower value implies a better priority. In the case of the same priority, the interface index will serve as the tiebreaker, with the lower-numbered interface being preferred over others. The permitted range is 0-240. The priority values can only be set in increments of

16.

3. Command Syntax: bridge GROUP instance INSTANCE_ID priority PRIORITY

GROUP <1-1> Specify the bridge-group ID.

INSTANCE_ID <1-15> Specify the instance ID.

PRIORITY <0-240> Specify the port priority in a range of <0-240>.

4. Example:

The following example sets the port priority (121) for Multiple Spanning Tree instance (3) to a port (fe1) in bridge GROUP (1): switch_a(config)#interface fe1 switch_a(config-if)#bridge-group 1 instance 3 priority 121 switch_a(config-if)#

Bridge-Group Instance Path-Cost:

1. Command Mode: Interface mode

Logon to Configure Mode (Configure Terminal Mode).

Then logon to Interface mode. fe1 means port 1.

The switch_a(config-if)# prompt will show on the screen. switch_a(config)#interface fe1 switch_a(config-if)#

2. Usage:

Use this command to set the cost of a path associated with an interface. Use the no parameter with this command to restore the default cost value of the path. A lower path-cost indicates a greater likelihood of the specific interface becoming a root.

3. Command Syntax: bridge GROUP instance INSTANCE_ID path-cost PATH_COST

GROUP <1-1> Specify the bridge-group ID.

INSTANCE_ID <1-15> Specify the instance ID.

PATH_COST <1-200000000> Specify the cost of path in the range of <1-200000000>.

4. Example:

The following example sets the path cost (1000) for Multiple Spanning Tree instance (3) to a port (fe1) in bridge GROUP (1): switch_a(config)#interface fe1 switch_a(config-if)#bridge-group 1 instance 3 path-cost 1000 switch_a(config-if)#

IES-0883 User Manual Page 107

Ring Setting

Ring state:

1. Command Mode: Configure mode

Logon to Configure Mode (Configure Terminal Mode).

The switch_a(config)# prompt will show on the screen. switch_a(config)#

2. Usage:

Use this command to enable Ring state. Use the no parameter with this command to disable Ring state.

3. Command Syntax: bridge GROUP protocol ring no bridge GROUP ring enable BRIDGE-FORWARD

GROUP <1-1> Specify the bridge-group ID.

BRIDGE-FORWARD Puts all ports of the specified bridge into the forwarding state.

4. Example:

The following example enables Ring state in bridge GROUP (1): switch_a(config)#bridge 1 protocol ring switch_a(config)#

Set ring port:

1. Command Mode: Configure mode

Logon to Configure Mode (Configure Terminal Mode).

The switch_a(config)# prompt will show on the screen. switch_a(config)#

2. Usage:

Use this command to set Ring port 1 and Ring port 2.

3. Command Syntax: ring set-port RING_PORT_1 RING_PORT_2

RING_PORT_1 Specify the Ring port 1.

RING_PORT_2 Specify the Ring port 2.

4. Example:

The following example sets the fe1 and fe2 as Ring port 1 and Ring port 2: switch_a(config)#ring set-port fe1 fe2 switch_a(config)#

IES-0883 User Manual Page 108

VLAN

VLAN Mode Setting, 802.1Q VLAN Setting, 802.1Q Port Setting, Port Based

VLAN

802.1Q VLAN Setting

VLAN Database:

1. Command Mode: Configure mode

Logon to Configure Mode (Configure Terminal Mode).

The switch_a(config)# prompt will show on the screen. switch_a(config)#

2. Usage:

Use vlan database command to enter the VLAN configuration mode.

3. Command Syntax: vlan database

4. Example:

The following example changes to VLAN configuration mode from Configure mode: switch_a(config)#vlan database switch_a(config-vlan)#

Add VLAN/Delete VLAN:

1. Command Mode: VLAN Configure mode

Logon to Configure Mode (Configure Terminal Mode).

Logon to VLAN Configure Mode.

The switch_a(config-vlan)# prompt will show on the screen. switch_a(config)#vlan database switch_a(config-vlan)#

2. Usage:

This command enables or disables the state of a p articular VLAN on a b ridge basis.

Specifying the disable state causes all forwarding over the specified VLAN ID on the specified bridge to cease. Specifying the enable state allows forwarding of frames on the specified VLAN-aware bridge.

3. Command Syntax: vlan VLANID bridge GROUP name VLAN_NAME state enable/disable no vlan VLANID bridge GROUP

VLANID The VID of the VLAN that will be enabled or disabled on the bridge <2-4094>.

GROUP <1-1> The ID of the bridge-group on which the VLAN will be affected.

VLAN_NAME The ASCII name of the VLAN. Maximum length: 16 characters. enable Sets VLAN into an enable state.

IES-0883 User Manual Page 109

disable Sets VLAN into a disable state.

4. Example:

The following example enables the vlan VLANID (2) and name VLAN_NAME (vlan2) of bridge GROUP (1): switch_a(config-vlan)#vlan 2 bridge 1 name vlan2 state enable switch_a(config-vlan)#

802.1Q Port Setting

Switchport mode access:

1. Command Mode: Interface mode

Logon to Configure Mode (Configure Terminal Mode).

Then logon to Interface mode. fe1 means port 1.

The switch_a(config-if)# prompt will show on the screen. switch_a(config)#interface fe1 switch_a(config-if)#

2. Usage:

Use switchport mode access command to set the switching characteristics of the Layer-2 interface to access mode, and classify untagged frames only.

Use the no switchport access command to reset the mode of the Layer-2 interface to access (default).

3. Command Syntax: switchport mode access no switchport access

4. Example:

The following example sets the switchport mode access of the interface fe1 (port 1): switch_a(config)#interface fe1 switch_a(config-if)#switchport mode access switch_a(config-if)#

Switchport mode hybrid:

1. Command Mode: Interface mode

Logon to Configure Mode (Configure Terminal Mode).

Then logon to Interface mode. fe1 means port 1.

The switch_a(config-if)# prompt will show on the screen. switch_a(config)#interface fe1 switch_a(config-if)#

IES-0883 User Manual Page 110

2. Usage:

Use switchport mode hybrid command to set the switching characteristics of the Layer-2 interface as hybrid, and classify both tagged and untagged frames.

Use the no switchport hybrid command to reset the mode of the Layer-2 interface to access (default).

3. Command Syntax: switchport mode hybrid switchport mode hybrid acceptable-frame-type all/vlan-tagged no switchport hybrid

all Set all frames can be received.

vlan-tagged Set vlan-tagged frames can only be received.

4. Example:

The following example sets the switchport mode hybrid of the interface fe1 (port 1) and all frames to be received on interface fe1 (port 1): switch_a(config)#interface fe1 switch_a(config-if)#switchport mode hybrid acceptable-frame-type all switch_a(config-if)#

Switchport mode trunk:

1. Command Mode: Interface mode

Logon to Configure Mode (Configure Terminal Mode).

Then logon to Interface mode. fe1 means port 1.

The switch_a(config-if)# prompt will show on the screen. switch_a(config)#interface fe1 switch_a(config-if)#

2. Usage:

Use switchport mode trunk command to set the switching characteristics of the Layer-2 interface as trunk, and specify only tagged frames.

Use the no switchport trunk command to reset the mode of the Layer-2 interface to access (default).

3. Command Syntax: switchport mode trunk no switchport trunk

4. Example:

The following example sets the switchport mode trunk of the interface fe1 (port 1): switch_a(config)#interface fe1 switch_a(config-if)#switchport mode trunk switch_a(config-if)#

IES-0883 User Manual Page 111

Switchport hybrid allowed vlan:

1. Command Mode: Interface mode

Logon to Configure Mode (Configure Terminal Mode).

Then logon to Interface mode. fe1 means port 1.

The switch_a(config-if)# prompt will show on the screen. switch_a(config)#interface fe1 switch_a(config-if)#

2. Usage:

Use this command to set the switching characteristics of the Layer-2 interface to hybrid.

Both tagged and untagged frames will be classified over hybrid interfaces.

Use the no parameter to turn off allowed hybrid switching.

3. Command Syntax: switchport hybrid allowed vlan all switchport hybrid allowed vlan none switchport hybrid allowed vlan add VLANID egress-tagged enable/disable switchport hybrid allowed vlan remove VLANID no switchport hybrid vlan all Allow all VLANs to transmit and receive through the Layer-2 interface. none Allow no VLANs to transmit and receive through the Layer-2 interface. add Add a VLAN to the member set. remove Remove a VLAN from the member set.

VLANID <2-4094> The ID of the VLAN or VLANs that will be added to, or removed from, the Layer-2 interface.

For a VLAN range, specify two VLAN numbers: lowest, then highest number in the range, separated by a hyphen.

For a VLAN list, specify the VLAN numbers separated by commas. egress-tagged enable Enable the egress tagging for the outgoing frames. disable Disable the egress tagging for the outgoing frames.

4. Example:

The following example specifies to add the interface fe1 (port 1) to VLANID (2) and enable the egress-tagged for the outgoing frames on interface fe1 (port 1): switch_a(config)#interface fe1 switch_a(config-if )#switchport hybrid allowed vlan add 2 egress-tagged enable switch_a(config-if )#

Switchport trunk allowed vlan:

1. Command Mode: Interface mode

Logon to Configure Mode (Configure Terminal Mode).

Then logon to Interface mode. fe1 means port 1.

IES-0883 User Manual Page 112

The switch_a(config-if)# prompt will show on the screen. switch_a(config)#interface fe1 switch_a(config-if)#

2. Usage:

Use this command to set the switching characteristics of the Layer-2 interface to trunk.

The all parameter indicates that any VLAN ID is part of its port’s member set. The none parameter indicates that no VLAN ID is configured on this port. The add and remove parameters will add and remove VLAN IDs to/from the port’s member set.

Use the no parameter to remove all VLAN IDs configured on this port.

3. Command Syntax: switchport trunk allowed vlan all switchport trunk allowed vlan none switchport trunk allowed vlan add VLANID switchport trunk allowed vlan remove VLANID switchport trunk allowed vlan except VLANID no switchport trunk vlan all Allow all VLANs to transmit and receive through the Layer-2 interface. none Allow no VLANs to transmit and receive through the Layer-2 interface. add Add a VLAN to transmit and receive through the Layer-2 interface. remove Remove a VLAN from transmit and receive through the Layer-2 interface. except All VLANs, except the VLAN for which the ID is specified, are part of its ports member set.

VLANID <2-4094> The ID of the VLAN or VLANs that will be added to, or removed from, the Layer-2 interface. A single VLAN, VLAN range, or VLAN list can be set.

For a VLAN range, specify two VLAN numbers: lowest, then highest number in the range, separated by a hyphen.

For a VLAN list, specify the VLAN numbers separated by commas.

4. Example:

The following example specifies to add the interface fe1 (port 1) to VLANID (2): switch_a(config)#interface fe1 switch_a(config-if)#switchport trunk allowed vlan add 2 switch_a(config-if)#

Port Based VLAN

Switchport portbase add/remove vlan:

1. Command Mode: Interface mode

Logon to Configure Mode (Configure Terminal Mode).

Then logon to Interface mode. fe1 means port 1.

The switch_a(config-if)# prompt will show on the screen. switch_a(config)#interface fe1 switch_a(config-if)#

IES-0883 User Manual Page 113

2. Usage:

Use this command to set or remove the default VLAN for the interface.

3. Command Syntax: switchport portbase add|remove vlan VLANID

VLANID The ID of the VLAN will be added to or removed from the Layer-2 interface.

4. Example:

The following example specifies to add the interface fe1 (port 1) to VLANID (2): switch_a(config)#interface fe1 switch_a(config-if)#switchport portbase add vlan 2 switch_a(config-if)#

IES-0883 User Manual Page 114

QoS

Global Configuration, 802.1p Priority, DSCP

Global Configuration

QoS:

1. Command Mode: Configure mode

Logon to Configure Mode (Configure Terminal Mode).

The switch_a(config)# prompt will show on the screen. switch_a(config)#

2. Usage:

Use mls qos enable command to globally enable QoS.

Use the no mls qos command to globally disable QoS.

3. Command Syntax: mls qos enable

(no) mls qos

4. Example:

The following example globally enables QoS on the switch: switch_a(config)#mls qos enable switch_a(config)#

Trust:

1. Command Mode: Configure mode

Logon to Configure Mode (Configure Terminal Mode).

The switch_a(config)# prompt will show on the screen. switch_a(config)#

2. Usage:

Use mls qos trust command to turn on QoS trust CoS or DSCP.

Use the no mls qos trust command to turn off QoS trust CoS or DSCP.

3. Command Syntax:

(no) mls qos trust cos/dscp

cos Class of Service.

dscp Differentiated Service Code Point.

4. Example:

The following example turns on QoS trust CoS on the switch: switch_a(config)#mls qos trust cos switch_a(config)#

IES-0883 User Manual Page 115

Strict Priority:

1. Command Mode: Configure mode

Logon to Configure Mode (Configure Terminal Mode).

The switch_a(config)# prompt will show on the screen. switch_a(config)#

2. Usage:

Use priority-queue out command to enable the egress expedite queue.

Use the no priority-queue out command to disable the egress expedite queue.

3. Command Syntax:

(no) priority-queue out

4. Example:

The following example enables the egress expedite queue on the switch: switch_a(config)#priority-queue out switch_a(config)#

Weighted Round Robin:

1. Command Mode: Configure mode

Logon to Configure Mode (Configure Terminal Mode).

The switch_a(config)# prompt will show on the screen. switch_a(config)#

2. Usage:

Use wrr-queue bandwidth command to specify the bandwidth ratios of the transmit queues.

3. Command Syntax: wrr-queue bandwidth WRR_WTS

WRR_WTS Weighted Round Robin (WRR) weights for the 4 queues (4 values separated by spaces). Range is 1-55.

4. Example:

The following example specifies the bandwidth ratios of the transmit queues on the switch: switch_a(config)#wrr-queue bandwidth 1 2 4 8 switch_a(config)#

802.1p Priority

1. Command Mode: Configure mode

IES-0883 User Manual Page 116

Logon to Configure Mode (Configure Terminal Mode).

The switch_a(config)# prompt will show on the screen. switch_a(config)#

2. Usage:

Use wrr-queue cos-map command to specify CoS values for a queue.

3. Command Syntax: wrr-queue cos-map QUEUE_ID COS_VALUE

QUEUE_ID Queue ID. Range is 0-3.

COS_VALUE CoS values. Up to 8 values (separated by spaces). Range is 0-7.

4. Example:

The following example shows mapping CoS values 0 and 1 to queue 1 on the switch: switch_a(config)#wrr-queue cos-map 1 0 1 switch_a(config)#

DSCP

1. Command Mode: Configure mode

Logon to Configure Mode (Configure Terminal Mode).

The switch_a(config)# prompt will show on the screen. switch_a(config)#

2. Usage:

Use mls qos map dscp-queue command to map the DSCP values to a queue.

3. Command Syntax: mls qos map dscp-queue DSCP_VALUE to QUEUE_ID

DSCP_VALUE DSCP values. Up to 8 values (separated by spaces). Range is 0-63.

QUEUE_ID Queue ID. Range is 0-3.

4. Example:

The following example shows mapping DSCP values 0 to 3 to queue 1 on the switch: switch_a(config)#mls qos map dscp-queue 0 1 2 3 to 1 switch_a(config)#

IES-0883 User Manual Page 117

SNMP

SNMP General Setting, SNMP v1/v2c, SNMP v3

SNMP General Setting

SNMP Status:

1. Command Mode: Configure mode

Logon to Configure Mode (Configure Terminal Mode).

The switch_a(config)# prompt will show on the screen. switch_a(config)#

2. Usage:

Use snmp-server enable command to enable and no snmp-server enable command to disable SNMP to the switch.

3. Command Syntax:

(no) snmp-server enable

4. Example:

The following example enables SNMP to the switch: switch_a(config)#snmp-server enable switch_a(config)#

Description:

1. Command Mode: Configure mode

Logon to Configure Mode (Configure Terminal Mode).

The switch_a(config)# prompt will show on the screen. switch_a(config)#

2. Usage:

Use snmp-server description command to specify and no snmp-server description command to remove description for SNMP.

3. Command Syntax: snmp-server description DESCRIPTION no snmp-server description

DESCRIPTION The description for SNMP.

4. Example:

The following example specifies description (description) for SNMP: switch_a(config)#snmp-server description description switch_a(config)#

IES-0883 User Manual Page 118

Location:

1. Command Mode: Configure mode

Logon to Configure Mode (Configure Terminal Mode).

The switch_a(config)# prompt will show on the screen. switch_a(config)#

2. Usage:

Use snmp-server location command to specify and no snmp-server location command to remove location for SNMP.

3. Command Syntax: snmp-server location LOCATION no snmp-server location

LOCATION The location for SNMP.

4. Example:

The following example specifies location (location) for SNMP: switch_a(config)#snmp-server location location switch_a(config)#

Contact:

1. Command Mode: Configure mode

Logon to Configure Mode (Configure Terminal Mode).

The switch_a(config)# prompt will show on the screen. switch_a(config)#

2. Usage:

Use snmp-server contact command to specify and no snmp-server contact command to remove contact for SNMP.

3. Command Syntax: snmp-server contact CONTACT no snmp-server contact

CONTACT The contact for SNMP.

4. Example:

The following example specifies contact (contact) for SNMP: switch_a(config)#snmp-server contact contact switch_a(config)#

Trap Community Name:

1. Command Mode: Configure mode

IES-0883 User Manual Page 119

Logon to Configure Mode (Configure Terminal Mode).

The switch_a(config)# prompt will show on the screen. switch_a(config)#

2. Usage:

Use this command to specify trap community name for SNMP.

Use the no parameter with this command to remove trap community name for SNMP.

3. Command Syntax: snmp-server trap-community <1-5> NAME no snmp-server trap-community <1-5>

<1-5> The trap community 1-5.

NAME The trap community name for SNMP.

4. Example:

The following example specifies trap community name 1 (name) for SNMP: switch_a(config)#snmp-server trap-community 1 name switch_a(config)#

Trap Host IP Address:

1. Command Mode: Configure mode

Logon to Configure Mode (Configure Terminal Mode).

The switch_a(config)# prompt will show on the screen. switch_a(config)#

2. Usage:

Use this command to specify trap host IP address for SNMP.

Use the no parameter with this command to remove trap host IP address for SNMP.

3. Command Syntax: snmp-server trap-ipaddress <1-5> IP-ADDRESS no snmp-server trap-ipaddress <1-5>

<1-5> The trap host IP address 1-5.

IP-ADDRESS The trap host IP address for SNMP. A.B.C.D specifies the IP address.

4. Example:

The following example specifies trap host 1 IP address (192.168.1.20) for SNMP: switch_a(config)#snmp-server trap-ipaddress 1 192.168.1.20 switch_a(config)#

Cold Start Trap:

1. Command Mode: Configure mode

Logon to Configure Mode (Configure Terminal Mode).

IES-0883 User Manual Page 120

The switch_a(config)# prompt will show on the screen. switch_a(config)#

2. Usage:

Use snmp-server trap-type enable coldStart command to enable cold start trap for

SNMP.

Use the no snmp-server trap-type enable coldStart command to disable cold start trap for SNMP.

3. Command Syntax:

(no) snmp-server trap-type enable coldStart

4. Example:

The following example enables cold start trap for SNMP: switch_a(config)#snmp-server trap-type enable coldStart switch_a(config)#

Warm Start Trap:

1. Command Mode: Configure mode

Logon to Configure Mode (Configure Terminal Mode).

The switch_a(config)# prompt will show on the screen. switch_a(config)#

2. Usage:

Use snmp-server trap-type enable warmStart command to enable warm start trap for

SNMP.

Use the no snmp-server trap-type enable warmStart command to disable warm start trap for SNMP.

3. Command Syntax:

(no) snmp-server trap-type enable warmStart

4. Example:

The following example enables warm start trap for SNMP: switch_a(config)#snmp-server trap-type enable warmStart switch_a(config)#

Link Down Trap:

1. Command Mode: Configure mode

Logon to Configure Mode (Configure Terminal Mode).

The switch_a(config)# prompt will show on the screen. switch_a(config)#

IES-0883 User Manual Page 121

2. Usage:

Use snmp-server trap-type enable linkDown command to enable link down trap for

SNMP.

Use the no snmp-server trap-type enable linkDown command to disable link down trap for SNMP.

3. Command Syntax:

(no) snmp-server trap-type enable linkDown

4. Example:

The following example enables link down trap for SNMP: switch_a(config)#snmp-server trap-type enable linkDown switch_a(config)#

Link Up Trap:

1. Command Mode: Configure mode

Logon to Configure Mode (Configure Terminal Mode).

The switch_a(config)# prompt will show on the screen. switch_a(config)#

2. Usage:

Use snmp-server trap-type enable linkUp command to enable link up trap for SNMP.

Use the no snmp-server trap-type enable linkUp command to disable link up trap for

SNMP.

3. Command Syntax:

(no) snmp-server trap-type enable linkUp

4. Example:

The following example enables link up trap for SNMP: switch_a(config)#snmp-server trap-type enable linkUp switch_a(config)#

Authentication Failure Trap:

1. Command Mode: Configure mode

Logon to Configure Mode (Configure Terminal Mode).

The switch_a(config)# prompt will show on the screen. switch_a(config)#

2. Usage:

Use snmp-server trap-type enable authenticationFailure command to enable authentication failure trap for SNMP.

Use the no snmp-server trap-type enable authenticationFailure command to disable

IES-0883 User Manual Page 122

authentication failure trap for SNMP.

3. Command Syntax:

(no) snmp-server trap-type enable authenticationFailure

4. Example:

The following example enables authentication failure trap for SNMP: switch_a(config)#snmp-server trap-type enable authenticationFailure switch_a(config)#

Topology Change Trap:

1. Command Mode: Configure mode

Logon to Configure Mode (Configure Terminal Mode).

The switch_a(config)# prompt will show on the screen. switch_a(config)#

2. Usage:

Use snmp-server trap-type enable topologyChange command to enable topology change trap for SNMP.

Use the no snmp-server trap-type enable topologyChange command to disable topology change trap for SNMP.

3. Command Syntax:

(no) snmp-server trap-type enable topologyChange

4. Example:

The following example enables topology change trap for SNMP: switch_a(config)#snmp-server trap-type enable topologyChange switch_a(config)#

SNMP v1/v2c

Get Community Name:

1. Command Mode: Configure mode

Logon to Configure Mode (Configure Terminal Mode).

The switch_a(config)# prompt will show on the screen. switch_a(config)#

2. Usage:

Use snmp-server community get command to specify and no snmp-server community

get command to remove get community name for SNMP.

3. Command Syntax: snmp-server community get NAME

IES-0883 User Manual Page 123

no snmp-server community get

NAME The get community name for SNMP.

4. Example:

The following example specifies get community name (name) for SNMP: switch_a(config)#snmp-server community get name switch_a(config)#

Set Community Name:

1. Command Mode: Configure mode

Logon to Configure Mode (Configure Terminal Mode).

The switch_a(config)# prompt will show on the screen. switch_a(config)#

2. Usage:

Use snmp-server community set command to specify and no snmp-server community

set command to remove set community name for SNMP.

3. Command Syntax: snmp-server community set NAME no snmp-server community set

NAME The set community name for SNMP.

4. Example:

The following example specifies set community name (name) for SNMP: switch_a(config)#snmp-server community set name switch_a(config)#

SNMP v3

SNMPv3 No-Auth:

1. Command Mode: Configure mode

Logon to Configure Mode (Configure Terminal Mode).

The switch_a(config)# prompt will show on the screen. switch_a(config)#

2. Usage:

Add a user using snmp v3 with read-only or read-write access mode and without authentication. Use the no form of the command to delete this user.

3. Command Syntax:

(no) snmp-server v3-user USERNAME (ro|rw) noauth

USERNAME Specify a user name. ro read-only access mode

IES-0883 User Manual Page 124

rw read-write access mode

4. Example:

The following example adds a user (myuser) using snmp v3 with read-only access mode and without authentication: switch_a(config)#snmp-server v3-user myuser ro noauth switch_a(config)#

SNMPv3 Auth-MD5, SNMPv3 Auth-SHA:

1. Command Mode: Configure mode

Logon to Configure Mode (Configure Terminal Mode).

The switch_a(config)# prompt will show on the screen. switch_a(config)#

2. Usage:

Add a user using snmp v3 with read-only or read-write access mode and with MD5 or SHA authentication. Use the no form of the command to delete this user.

3. Command Syntax:

(no) snmp-server v3-user USERNAME (ro|rw) auth (md5|sha) AUTH_PASSWORD

USERNAME Specify a user name. ro read-only access mode rw read-write access mode md5 authentication method sha authentication method

AUTH_PASSWORD authentication password

4. Example:

The following example adds a user (myuser) using snmp v3 with read-write access mode and MD5 authentication (mypassword): switch_a(config)#snmp-server v3-user myuser rw auth md5 mypassword switch_a(config)#

SNMPv3 Priv Auth-MD5, SNMPv3 Priv Auth-SHA:

1. Command Mode: Configure mode

Logon to Configure Mode (Configure Terminal Mode).

The switch_a(config)# prompt will show on the screen. switch_a(config)#

2. Usage:

Add a user using snmp v3 with read-only or read-write access mode, MD5 or SHA authentication, and privacy. Use the no form of the command to delete this user.

IES-0883 User Manual Page 125

3. Command Syntax:

(no) snmp-server v3-user USERNAME (ro|rw) priv auth (md5|sha) AUTH_PASSWORD des PRIV_PASS_PHRASE

USERNAME Specify a user name. ro read-only access mode rw read-write access mode md5 authentication method sha authentication method

AUTH_PASSWORD authentication password

PRIV_PASS_PHRASE encryption pass phrase

4. Example:

The following example adds a user (myuser) using snmp v3 with read-write access mode,

MD5 authentication (mypassword), and encryption pass phrase (mypassphrase): switch_a(config)#snmp-server v3-user myuser rw priv md5 mypassword des mypassphrase switch_a(config)#

IES-0883 User Manual Page 126

802.1x

Radius Configuration, Port Authentication

Radius Configuration

Radius Status:

1. Command Mode: Configure mode

Logon to Configure Mode (Configure Terminal Mode).

The switch_a(config)# prompt will show on the screen. switch_a(config)#

2. Usage:

Use dot1x system-auth-ctrl command to globally enable authentication.

Use no dot1x system-auth-ctrl command to globally disable authentication.

3. Command Syntax:

(no) dot1x system-auth-ctrl

4. Example:

The following example globally enables authentication: switch_a(config)#dot1x system-auth-ctrl switch_a(config)#

Radius Server IP:

Radius Server Port:

1. Command Mode: Configure mode

Logon to Configure Mode (Configure Terminal Mode).

The switch_a(config)# prompt will show on the screen. switch_a(config)#

2. Usage:

Use this command to specify the IP address of the remote radius server host and assign authentication and accounting destination port number.

3. Command Syntax:

(no) radius-server host IP-ADDRESS auth-port PORT

IP-ADDRESS A.B.C.D specifies the IP address of the radius server host.

PORT specifies the UDP destination port for authentication requests. The host is not used for authentication if set to 0.

4. Example:

The following example specifies the IP address (192.168.1.100) of the remote radius server host and assigns authentication and accounting destination port number (1812): switch_a(config)#radius-server host 192.168.1.100 auth-port 1812

IES-0883 User Manual Page 127

switch_a(config)#

Secret Key:

1. Command Mode: Configure mode

Logon to Configure Mode (Configure Terminal Mode).

The switch_a(config)# prompt will show on the screen. switch_a(config)#

2. Usage:

Use this command to set the shared secret key between a Radius server and a client.

3. Command Syntax:

(no) radius-server host IP-ADDRESS key KEY

IP-ADDRESS A.B.C.D specifies the IP address of the radius server host.

KEY specifies the secret key shared among the radius server and the 802.1x client.

4. Example:

The following example specifies the IP address (192.168.1.100) of the remote radius server host and set the secret key (ipi) shared among the radius server and the 802.1x client: switch_a(config)#radius-server host 192.168.1.100 key ipi switch_a(config)#

Timeout:

1. Command Mode: Configure mode

Logon to Configure Mode (Configure Terminal Mode).

The switch_a(config)# prompt will show on the screen. switch_a(config)#

2. Usage:

Use this command to specify the number of seconds a Switch waits for a reply to a radius request before retransmitting the request.

3. Command Syntax: radius-server timeout SEC no radius-server timeout

SEC <1-1000> The number of seconds for a Switch to wait for a server host to reply before timing out. Enter a value in the range 1 to 1000.

4. Example:

The following example specifies 20 seconds for the Switch to wait for a server host to reply before timing out: switch_a(config)#radius-server timeout 20

IES-0883 User Manual Page 128

switch_a(config)#

Retransmit:

1. Command Mode: Configure mode

Logon to Configure Mode (Configure Terminal Mode).

The switch_a(config)# prompt will show on the screen. switch_a(config)#

2. Usage:

Use this command to specify the number of times the Switch transmits each radius request to the server before giving up.

3. Command Syntax: radius-server retransmit RETRIES no radius-server retransmit

RETRIES <1-100> Specifies the retransmit value. Enter a value in the range 1 to 100.

4. Example:

The following example specifies the retransmit value 12: switch_a(config)#radius-server retransmit 12 switch_a(config)#

Port Authentication

Authentication State:

1. Command Mode: Interface mode

Logon to Configure Mode (Configure Terminal Mode).

Then logon to Interface mode. fe1 means port 1.

The switch_a(config-if)# prompt will show on the screen. switch_a(config)#interface fe1 switch_a(config-if)#

2. Usage:

Use dot1x reauthetication command to enable reauthentication on a port.

Use no dot1x reauthetication command to disable reauthentication on a port.

3. Command Syntax:

(no) dot1x reauthentication

4. Example:

The following example specifies to enable reauthetication on the interface fe1 (port 1): switch_a(config)#interface fe1 switch_a(config-if)#dot1x reauthentication

IES-0883 User Manual Page 129

switch_a(config-if)#

Port Control:

1. Command Mode: Interface mode

Logon to Configure Mode (Configure Terminal Mode).

Then logon to Interface mode. fe1 means port 1.

The switch_a(config-if)# prompt will show on the screen. switch_a(config)#interface fe1 switch_a(config-if)#

2. Usage:

Use this command to force a port state.

Use no dot1x port-control command to remove a port from the 802.1x management.

3. Command Syntax: dot1x port-control auto|force-authorized|force-unauthorized no dot1x port-control

auto Specify to enable authentication on port.

force-authorized Specify to force a port to always be in an authorized state.

force-unauthorized Specify to force a port to always be in an unauthorized state.

4. Example:

The following example specifies to enable authetication on the interface fe1 (port 1): switch_a(config)#interface fe1 switch_a(config-if)#dot1x port-control auto switch_a(config-if)#

Periodic Reauthentication:

Reauthentication Period:

1. Command Mode: Interface mode

Logon to Configure Mode (Configure Terminal Mode).

Then logon to Interface mode. fe1 means port 1.

The switch_a(config-if)# prompt will show on the screen. switch_a(config)#interface fe1 switch_a(config-if)#

2. Usage:

Use this command to set the interval between reauthorization attempts.

Use no dot1x timeout re-authperiod command to delete the interval between reauthorization attempts.

IES-0883 User Manual Page 130

3. Command Syntax: dot1x timeout re-authperiod SECS no dot1x timeout re-authperiod

SECS <1-4294967295> Specify the seconds between reauthorization attempts. The default time is 3600 seconds.

4. Example:

The following example specifies to set the interval 25 seconds between reauthorization attempts: switch_a(config)#interface fe1 switch_a(config-if)#dot1x timeout re-authperiod 25 switch_a(config-if)#

IES-0883 User Manual Page 131

Other Protocols

GVRP, IGMP Snooping, NTP

GVRP

GVRP:

1. Command Mode: Configure mode

Logon to Configure Mode (Configure Terminal Mode).

The switch_a(config)# prompt will show on the screen. switch_a(config)#

2. Usage:

Use set gvrp enable bridge command to enable (set) and set gvrp disable bridge command to disable (reset) GVRP globally for the bridge instance. This command does not enable/disable GVRP in all ports of the bridge. After enabling GVRP globally, use the set

port gvrp enable command to enable GVRP on individual ports of the bridge.

3. Command Syntax: set gvrp enable bridge GROUP set gvrp disable bridge GROUP

GROUP Bridge-group ID used for bridging.

4. Example:

The following example globally enables GVRP to bridge GROUP (1): switch_a(config)#set gvrp enable bridge 1 switch_a(config)#

Dynamic VLAN creation:

1. Command Mode: Configure mode

Logon to Configure Mode (Configure Terminal Mode).

The switch_a(config)# prompt will show on the screen. switch_a(config)#

2. Usage:

Use set gvrp dynamic-vlan-creation enable bridge command to enable and set gvrp

dynamic-vlan-creation disable bridge command to disable dynamic VLAN creation for a specific bridge instance.

3. Command Syntax: set gvrp dynamic-vlan-creation enable bridge GROUP set gvrp dynamic-vlan-creation disable bridge GROUP

GROUP Bridge-group ID used for bridging.

4. Example:

IES-0883 User Manual Page 132

The following example enables dynamic VLAN creation for bridge GROUP (1): switch_a(config)#set gvrp dynamic-vlan-creation enable bridge 1 switch_a(config)#

Per port setting:

GVRP:

1. Command Mode: Configure mode

Logon to Configure Mode (Configure Terminal Mode).

The switch_a(config)# prompt will show on the screen. switch_a(config)#

2. Usage:

Use set port gvrp enable command to enable and set port gvrp disable command to disable GVRP on a port or all ports in a bridge.

3. Command Syntax: set port gvrp enable all/IFNAME set port gvrp disable all/IFNAME all All ports added to recently configured bridge.

IFNAME The name of the interface.

4. Example:

The following example enables GVRP on the interface fe1 (port 1): switch_a(config)#set port gvrp enable fe1 switch_a(config)#

Per port setting:

GVRP applicant:

1. Command Mode: Configure mode

Logon to Configure Mode (Configure Terminal Mode).

The switch_a(config)# prompt will show on the screen. switch_a(config)#

2. Usage:

Use this command to set the GVRP applicant state to normal or active.

3. Command Syntax: set gvrp applicant state active/normal IFNAME active Active state normal Normal state

IFNAME Name of the interface.

4. Example:

IES-0883 User Manual Page 133

The following example sets GVRP applicant state to active on the interface fe1 (port 1): switch_a(config)#set gvrp applicant state active fe1 switch_a(config)#

Per port setting:

GVRP registration:

1. Command Mode: Configure mode

Logon to Configure Mode (Configure Terminal Mode).

The switch_a(config)# prompt will show on the screen. switch_a(config)#

2. Usage:

Use this command to set GVRP registration to normal, fixed, and forbidden registration mode for a given port.

3. Command Syntax: set gvrp registration normal IF_NAME set gvrp registration fixed IF_NAME set gvrp registration forbidden IF_NAME normal Specify dynamic GVRP multicast registration and deregistration on the port. fixed Specify the multicast groups currently registered on the switch are applied to the port, but any subsequent registrations or deregistrations do not affect the port. Any registered multicast groups on the port are not deregistered based on the GARP timers. forbidden Specify that all GVRP multicasts are deregistered, and prevent any further

GVRP multicast registration on the port.

IF_NAME The name of the interface.

4. Example:

The following example sets GVRP registration to fixed registration mode on the interface fe1 (port 1): switch_a(config)#set gvrp registration fixed fe1 switch_a(config)#

IGMP Snooping

IGMP mode:

Querier:

1. Command Mode: Configure mode

Logon to Configure Mode (Configure Terminal Mode).

The switch_a(config)# prompt will show on the screen. switch_a(config)#

2. Usage:

Use ip igmp snooping querier command to enable IGMP querier operation on a subnet

IES-0883 User Manual Page 134

(VLAN) when no multicast routing protocol is configured in the subnet (VLAN). When enabled, the IGMP Snooping querier sends out periodic IGMP queries for all interfaces on that VLAN.

Use the no ip igmp snooping querier command to disable IGMP querier configuration.

3. Command Syntax:

(no) ip igmp snooping querier

4. Example:

The following example enables IGMP snooping querier: switch_a(config)# ip igmp snooping querier switch_a(config)#

IGMP mode:

Passive:

1. Command Mode: Configure mode

Logon to Configure Mode (Configure Terminal Mode).

The switch_a(config)# prompt will show on the screen. switch_a(config)#

2. Usage:

Use ip igmp snooping command to enable IGMP Snooping. This command is given in the

Global Config mode. IGMP Snooping is enabled at the switch level.

Use the no ip igmp snooping command to globally disable IGMP Snooping.

3. Command Syntax:

(no) ip igmp snooping enable

4. Example:

The following example enables IGMP snooping on the switch: switch_a(config)# ip igmp snooping enable switch_a(config)#

IGMP version:

1. Command Mode: Interface mode

Logon to Configure Mode (Configure Terminal Mode).

Then logon to Interface mode. vlan1.1 means vlan 1.

The switch_a(config-if)# prompt will show on the screen. switch_a(config)#interface vlan1.1 switch_a(config-if)#

2. Usage:

IES-0883 User Manual Page 135

Use ip igmp version command to set the current IGMP protocol version on an interface.

To return to the default version, use the no ip igmp version command.

3. Command Syntax: ip igmp version VERSION no ip igmp version

VERSION IGMP protocol version number.

4. Example:

The following example sets the IGMP protocol version 3 on vlan1.1: switch_a(config)#interface vlan1.1 switch_a(config-if)#ip igmp version 3 switch_a(config-if)#

Fast-leave:

1. Command Mode: Interface mode

Logon to Configure Mode (Configure Terminal Mode).

Then logon to Interface mode. vlan1.1 means vlan 1.

The switch_a(config-if)# prompt will show on the screen. switch_a(config)#interface vlan1.1 switch_a(config-if)#

2. Usage:

Use ip igmp snooping fast-leave command to enable IGMP Snooping fast-leave processing. Fast-leave processing is analogous to immediate leave processing; the IGMP group-membership is removed, as soon as an IGMP leave group message is received without sending out a group-specific query.

Use the no ip igmp snooping fast-leave command to disable fast-leave processing.

3. Command Syntax:

(no) ip igmp snooping fast-leave

4. Example:

The following example enables IGMP snooping fast-leave on vlan1.1: switch_a(config)#interface vlan1.1 switch_a(config-if)#ip igmp snooping fast-leave switch_a(config-if)#

IGMP querier:

Query-interval:

1. Command Mode: Interface mode

Logon to Configure Mode (Configure Terminal Mode).

IES-0883 User Manual Page 136

Then logon to Interface mode. vlan1.1 means vlan 1.

The switch_a(config-if)# prompt will show on the screen. switch_a(config)#interface vlan1.1 switch_a(config-if)#

2. Usage:

Use ip igmp query-interval command to configure the frequency of sending IGMP host query messages.

To return to the default frequency, use the no ip igmp query-interval command.

3. Command Syntax: ip igmp query-interval INTERVAL no ip igmp query-interval

INTERVAL <1-18000> Frequency (in seconds) at which IGMP host query messages are sent. Default: 125 seconds.

4. Example:

The following example changes the frequency of sending IGMP host-query messages to 2 minutes on vlan1.1: switch_a(config)#interface vlan1.1 switch_a(config-if)#ip igmp query-interval 120 switch_a(config-if)#

IGMP querier:

Max-response-time:

1. Command Mode: Interface mode

Logon to Configure Mode (Configure Terminal Mode).

Then logon to Interface mode. vlan1.1 means vlan 1.

The switch_a(config-if)# prompt will show on the screen. switch_a(config)#interface vlan1.1 switch_a(config-if)#

2. Usage:

Use ip igmp query-max-response-time command to configure the maximum response time advertised in IGMP queries.

To restore to the default value, use the no ip igmp query-max-response-time command.

3. Command Syntax: ip igmp query-max-response-time RESPONSETIME no ip igmp query-max-response-time

RESPONSETIME <1-240> Maximum response time (in seconds) advertised in IGMP queries. Default: 10 seconds.

IES-0883 User Manual Page 137

4. Example:

The following example configures a maximum response time of 8 seconds on vlan1.1: switch_a(config)#interface vlan1.1 switch_a(config-if)#ip igmp query-max-response-time 8 switch_a(config-if)#

IGMP passive snooping:

Static mc router port:

1. Command Mode: Interface mode

Logon to Configure Mode (Configure Terminal Mode).

Then logon to Interface mode. vlan1.1 means vlan 1.

The switch_a(config-if)# prompt will show on the screen. switch_a(config)#interface vlan1.1 switch_a(config-if)#

2. Usage:

Use ip igmp snooping mrouter interface command to statically configure the specified

VLAN constituent interface as a multicast router interface for IGMP Snooping in that VLAN.

Use the no ip igmp snooping mrouter interface command to remove the static configuration of the interface as a multicast router interface.

3. Command Syntax:

(no) ip igmp snooping mrouter interface IFNAME

IFNAME Specify the name of the interface

4. Example:

The following example shows interface fe1 (port 1) statically configured to be a multicast router interface on vlan1.1: switch_a(config)#interface vlan1.1 switch_a(config-if)#ip igmp snooping mrouter interface fe1 switch_a(config-if)#

IGMP passive snooping:

Report suppression:

1. Command Mode: Interface mode

Logon to Configure Mode (Configure Terminal Mode).

Then logon to Interface mode. vlan1.1 means vlan 1.

The switch_a(config-if)# prompt will show on the screen. switch_a(config)#interface vlan1.1 switch_a(config-if)#

IES-0883 User Manual Page 138

2. Usage:

Use ip igmp snooping report-suppression command to enable report suppression for

IGMP versions 1 and 2.

Use the no ip igmp snooping report-suppression command to disable report suppression.

3. Command Syntax:

(no) ip igmp snooping report-suppression

4. Example:

The following example enables report suppression for IGMPv2 reports on vlan1.1: switch_a(config)#interface vlan1.1 switch_a(config-if)#ip igmp version 2 switch_a(config-if)#ip igmp snooping report-suppression switch_a(config-if)#

NTP

NTP Status:

1. Command Mode: Configure mode

Logon to Configure Mode (Configure Terminal Mode).

The switch_a(config)# prompt will show on the screen. switch_a(config)#

2. Usage:

Use ntp enable command to enable NTP for the Switch.

Use no ntp enable command to disable NTP for the Switch.

3. Command Syntax:

(no) ntp enable

4. Example:

The following example enables NTP for the Switch: switch_a(config)#ntp enable switch_a(config)#

NTP Server:

1. Command Mode: Configure mode

Logon to Configure Mode (Configure Terminal Mode).

The switch_a(config)# prompt will show on the screen. switch_a(config)#

2. Usage:

IES-0883 User Manual Page 139

Use this command to specify the IP address or Domain name of NTP server.

3. Command Syntax: ntp server IP-ADDRESS|DOMAIN-NAME

IP-ADDRESS A.B.C.D specifies the IP address of NTP server.

DOMAIN-NAME Specifies the Domain name of NTP server.

4. Example:

The following example specifies the IP address (192.168.1.100) of NTP server: switch_a(config)#ntp server 192.168.1.100 switch_a(config)#

Sync Time:

1. Command Mode: Configure mode

Logon to Configure Mode (Configure Terminal Mode).

The switch_a(config)# prompt will show on the screen. switch_a(config)#

2. Usage:

Use ntp sync-time command to synchronize time with NTP server.

3. Command Syntax: ntp sync-time

4. Example:

The following example synchronizes time with NTP server: switch_a(config)#ntp sync-time switch_a(config)#

Time Zone:

1. Command Mode: Configure mode

Logon to Configure Mode (Configure Terminal Mode).

The switch_a(config)# prompt will show on the screen. switch_a(config)#

2. Usage:

Use this command to to set time zone.

3. Command Syntax: clock timezone TIMEZONE

TIMEZONE Specifies the time zone. (Please refer the Appendix B)

4. Example:

IES-0883 User Manual Page 140

The following example sets time zone (Canada/Yukon): switch_a(config)#clock timezone YST9YDT switch_a(config)#

Polling Interval:

1. Command Mode: Configure mode

Logon to Configure Mode (Configure Terminal Mode).

The switch_a(config)# prompt will show on the screen. switch_a(config)#

2. Usage:

Use this command to specify the polling interval.

3. Command Syntax: ntp polling-interval MINUTE

MINUTE <1-10080> The polling interval. Enter a value in the range 1 to 10080 minutes.

4. Example:

The following example specifies the polling interval 60 minutes: switch_a(config)#ntp polling interval 60 switch_a(config)#

Daylight Saving Mode:

1. Command Mode: Configure mode

Logon to Configure Mode (Configure Terminal Mode).

The switch_a(config)# prompt will show on the screen. switch_a(config)#

2. Usage:

Use this command to enable daylight saving.

Use no clock summer-time command to disable daylight saving.

3. Command Syntax: clock summer-time TIMEZONE weekday WEEK DAY MONTH HOUR MINUTE WEEK DAY

MONTH HOUR MINUTE OFFSET

TIMEZONE Specifies the daylight saving timezone.

WEEK <1-5> Specifies weekdays from Monday to Friday.

DAY <0-6> Specifies from Sunday to Saturday.

MONTH <1-12> Specifies from January to December.

HOUR <0-23> Specifies from 0 to 23.

MINUTE <0-59> Specifies from 0 to 59.

OFFSET <1-1440> Specifies from 1 to 1440 minutes. clock summer-time TIMEZONE date DAY MONTH HOUR MINUTE DAY MONTH HOUR

MINUTE OFFSET

IES-0883 User Manual Page 141

TIMEZONE Specifies the daylight saving timezone.

DAY <1-31> Specifies from 1 to 31.

MONTH <1-12> Specifies from January to December.

HOUR <0-23> Specifies from 0 to 23.

MINUTE <0-59> Specifies from 0 to 59.

OFFSET <1-1440> Specifies from 1 to 1440 minutes. no clock summer-time

4. Example:

The following example sets clock summer-time TIMEZONE (onehour) as daylight saving offset 60 minutes from 4 April AM0:00 to 31 October AM0:00: switch_a(config)#clock summer-time onehour date 4 4 0 0 31 10 0 0 60 switch_a(config)#

IES-0883 User Manual Page 142

Specifications

Applicable Standards

IEEE 802.3 10Base-T

IEEE 802.3u 100Base-TX

IEEE 802.3ab 1000Base-T

IEEE 802.3z 1000Base-SX/LX/BX

Switching Method

Store-and-Forward

Forwarding Rate

10Base-T

100Base-TX

1000Base-T/SX/LX/BX

Performance

10 / 20Mbps half / full-duplex

100 / 200Mbps half / full-duplex

2000Mbps full-duplex

Cable

10Base-T

100Base-TX

1000Base-T

1000Base-SX/LX/BX

14,880pps for 10Mbps

148,810pps for 100Mbps

1,488,100pps for 1000Mbps

2-pair UTP/STP Cat. 3, 4, 5 Up to 100m (328ft)

2-pair UTP/STP Cat. 5 Up to 100m (328ft)

4-pair UTP/STP Cat. 5 Up to 100m (328ft)

MMF (50 or 62.5µm), SMF (10µm)

LED Indicators

Dimensions

Per unit – Power (Power 1, Power 2, Power 3), Alarm

Per port –

10/100/1000TX: LNK/ACT, 10/100/1000

1000SX/LX/BX: LNK/ACT, 1000

60mm (W) x 125mm (D) x 145mm (H)

(2.36” (W) x 4.92” (D) x 5.71” (H))

Net Weight

Power Input

1Kg (2.2lbs.)

DC Jack: 12VDC, External AC/DC required

Terminal Block: 12-32VDC

Operating Voltage &

Max. Current

Consumption

1.7A @ 12VDC, 0.85A @ 24VDC

Power Consumption

20.4W Max.

Operating

Temperature

-20°C to 60℃ (-4℉ to 140℉)

UL508 Industrial Control Equipment certified

Maximum Surrounding Air Temperature @ 60℃

(140℉)

Storage Temperature

-40°C to 85℃ (-40℉ to 185℉)

Humidity

5%-95% non-condensing

Safety

EMI

UL508

EMS

Environmental Test

Compliance

FCC Part 15, Class A

EN61000-6-4: EN55022, EN61000-3-2, EN61000-3-3

EN61000-6-2:

EN61000-4-2 (ESD Standard)

EN61000-4-3 (Radiated RFI Standards)

EN61000-4-4 (Burst Standards)

EN61000-4-5 (Surge Standards)

EN61000-4-6 (Induced RFI Standards)

EN61000-4-8 (Magnetic Field Standards)

IEC60068-2-6 Fc (Vibration Resistance)

IEC60068-2-27 Ea (Shock)

IEC60068-2-32 Ed (Free Fall)

IES-0883 User Manual Page 143

Appendix A

4

5

6

2

3

DB9 DCE pin assignment

Pin no.

1

Name

DCD

7

8

9

RxD

TxD

---

GND

DSR

---

CTS

---

RS232 Signal name

Data Carrier detect

Received data

Transmit data

N/C

Signal ground

Data set Ready

N/C

Clear to send

N/C

IES-0883 User Manual Page 144

GMT0BST

WET0WETDST

PWT0PST

MST-3MDT

EUT-1EUTDST

EUT-2EUTDST

EUT-3EUTDST

EUT-4EUTDST

EUT-6EUTDST

EUT-8EUTDST

Russian Federation

RFT-2RFTDST

RFT-3RFTDST

RFT-4RFTDST

RFT-5RFTDST

RFT-6RFTDST

RFT-7RFTDST

RFT-8RFTDST

RFT-9RFTDST

RFT-10RFTDST

Appendix B

Time Zone

Europe

MEZ-1MESZ

MET-1METDST

EET-2EETDST

Country and City Lists

Europe/Vienna, Europe/Berlin, Europe/Zurich

Africa/Tunis, CET, MET, Europe/Tirane,

Europe/Andorra, Europe/Brussels, Europe/Prague,

Europe/Copenhagen, Europe/Paris,

Europe/Gibraltar, Europe/Budapest, Europe/Rome,

Europe/Vaduz, Europe/Luxembourg, Europe/Malta,

Europe/Monaco, Europe/Amsterdam, Europe/Oslo,

Europe/Warsaw, Europe/Belgrade, Europe/Madrid,

Africa/Ceuta, Europe/Stockholm, Europe/Vatican,

Europe/San_Marino, Arctic/Longyearbyen,

Atlantic/Jan_Mayen, Europe/Ljubljana,

Europe/Sarajevo, Europe/Skopje, Europe/Zagreb,

Europe/Bratislava, Poland

Asia/Nicosia, EET, Europe/Minsk, Europe/Sofia,

Europe/Athens, Europe/Vilnius, Europe/Chisinau,

Europe/Istanbul, Europe/Kiev, Europe/Uzhgorod,

Europe/Zaporozhye, Europe/Nicosia, Asia/Istanbul,

Europe/Tiraspol, Turkey

Europe/London, Europe/Dublin, Eire,

Europe/Belfast, GB, GB-Eire

WET, Atlantic/Faeroe, Atlantic/Madeira,

Atlantic/Canary

Europe/Lisbon, Portugal

Europe/Moscow, W-SU

America/Scoresbysund, Atlantic/Azores

Asia/Beirut, Europe/Simferopol

Asia/Tbilisi

Europe/Samara

Asia/Almaty, Asia/Qyzylorda

Asia/Ulaanbaatar

Europe/Kaliningrad

Europe/Moscow

Asia/Yerevan, Asia/Baku, Asia/Oral, Asia/Ashkhabad

Asia/Aqtobe, Asia/Aqtau, Asia/Bishkek,

Asia/Yekaterinburg

Asia/Omsk, Asia/Novosibirsk

Asia/Hovd, Asia/Krasnoyarsk

Asia/Irkutsk, Asia/Chungking, Asia/Ulan_Bator

Asia/Choibalsan, Asia/Yakutsk

Asia/Vladivostok

IES-0883 User Manual Page 145

RFT-11RFTDST

RFT-12RFTDST

North America

PST8PDT

MST7MDT

MST7

CST6CDT

EST5EDT

AST4ADT

EST5

AST10ADT

YST9YDT

NST3:30NDT

NAST3NADT

NAST9NADT

Asia/Sakhalin, Asia/Magadan

Asia/Kamchatka, Asia/Anadyr

America/Los_Angeles, US/Pacific-New, PST8PDT,

US/Pacific, SystemV/PST8PDT

America/Denver, America/Boise,

America/Cambridge_Bay, America/Shiprock,

MST7MDT, Navajo, US/Mountain,

SystemV/MST7MDT

America/Phoenix, MST, US/Arizona, SystemV/MST7

America/Chicago, America/North_Dakota/Center,

America/Menominee, America/Costa_Rica,

America/Managua, CST6CDT, US/Central,

SystemV/CST6CDT

America/New_York, America/Kentucky/Louisville,

America/Kentucky/Monticello, America/Detroit,

America/Pangnirtung, America/Louisville, EST5EDT,

US/Eastern, US/Michigan, SystemV/EST5EDT

America/Thule, Atlantic/Bermuda,

SystemV/AST4ADT

America/Coral_Harbour, America/Cayman,

America/Jamaica,

America/Panama, EST, Jamaica, SystemV/EST5

America/Adak, America/Atka, US/Aleutian

Canada/Yukon

America/St_Johns, Canada/Newfoundland

America/Godthab, America/Miquelon

Pacific/Pitcairn, America/Juneau, America/Yakutat,

America/Anchorage, America/Nome, US/Alaska,

SystemV/YST9YDT, SystemV/PST8

South America & Central America

TTST4

SAT3

EBST3EBDT

America/Port_of_Spain

America/Argentina/Buenos_Aires,

America/Argentina/Cordoba,

America/Argentina/Tucuman,

America/Argentina/La_Rioja,

America/Argentina/San_Juan,

America/Argentina/Jujuy,

America/Argentina/Catamarca,

America/Argentina/Mendoza,

America/Argentina/Rio_Gallegos,

America/Argentina/Ushuaia,

America/Argentina/ComodRivadavia,

America/Buenos_Aires, America/Cordoba,

America/Jujuy, America/Mendoza

America/Fortaleza, America/Recife,

America/Araguaina, America/Maceio,

IES-0883 User Manual Page 146

WBST4WBDT

ACRE5

NORO2

CST4CDT

EIST6EIDT

Asia

MST-8

CST-8

Oceania

CST-9:30CDT

EST-10EDT

LHT-10:30LHDT

TST-10TDT

NZST-12NZDT

CIST-12:45CIDT

Africa

SAST-2

EST-2EDT

UAEST-4

IST-3IDT

JST-2JDT

SST-2SDT

Universal

UCT

IES-0883 User Manual

America/Bahia, America/Sao_Paulo,

America/Cuiaba, America/Montevideo,

America/Catamarca, America/Rosario, Brazil/East

America/Campo_Grande, America/Boa_Vista,

America/Manaus, Atlantic/Stanley,

America/Asuncion, Brazil/West

America/Rio_Branco, America/Porto_Acre,

Brazil/Acre

America/Noronha, Brazil/DeNoronha

Antarctica/Palmer, America/Santiago,

Chile/Continental

Pacific/Easter, Chile/EasterIsland

Asia/Kuala_Lumpur, Asia/Kuching

Asia/Harbin, Asia/Shanghai, Asia/Chongqing,

Asia/Urumqi, Asia/Kashgar, Asia/Hong_Kong,

Asia/Macau, Asia/Macao, Hongkong, PRC, ROC

Australia/Adelaide, Australia/Broken_Hill,

Australia/South, Australia/Yancowinna

Australia/Brisbane, Australia/Lindeman,

Australia/Currie, Australia/Melbourne,

Australia/Sydney, Australia/ACT, Australia/Canberra,

Australia/NSW, Australia/Queensland,

Australia/Tasmania, Australia/Victoria

Australia/Lord_Howe, Australia/LHI

Australia/Hobart

Antarctica/McMurdo, Pacific/Auckland,

Antarctica/South_Pole, NZ

Pacific/Chatham, NZ-CHAT

Africa/Maseru, Africa/Johannesburg,

Africa/Mbabane

Africa/Cairo, Egypt

Asia/Dubai

Asia/Baghdad

Asia/Amman

Asia/Damascus

Africa/Ouagadougou, Africa/Abidjan, Africa/Banjul,

Africa/Accra, Africa/Conakry, Africa/Bissau,

Africa/Monrovia, Africa/Bamako, Africa/Nouakchott,

Africa/Casablanca, Africa/El_Aaiun,

Atlantic/St_Helena, Africa/Sao_Tome, Africa/Dakar,

Africa/Freetown, Africa/Lome,

America/Danmarkshavn, Atlantic/Reykjavik,

Etc/GMT, Etc/UTC, Etc/UCT, GMT, Etc/Universal,

Page 147

UCT5

UCT6

UCT7

UCT8

UCT9

UCT10

UCT11

UCT-1

UCT-2

UCT-3

UCT1

UCT2

UCT3

UCT4

IES-0883 User Manual

Etc/Zulu, Etc/Greenwich, Etc/GMT-0, Etc/GMT+0,

Etc/GMT0, Africa/Timbuktu, GMT+0, GMT-0, GMT0,

Greenwich, Iceland, UCT, UTC, Universal, Zulu

Atlantic/Cape_Verde, Etc/GMT+1

Atlantic/South_Georgia, Etc/GMT+2

Antarctica/Rothera, America/Belem,

America/Cayenne, America/Paramaribo, Etc/GMT+3

America/Anguilla, America/Antigua,

America/Barbados, America/Dominica,

America/Grenada, America/Guadeloupe,

America/Martinique, America/Montserrat,

America/Puerto_Rico, America/St_Kitts,

America/St_Lucia, America/St_Vincent,

America/Tortola, America/St_Thomas,

America/Aruba, America/La_Paz,

America/Porto_Velho, America/Curacao,

America/Caracas, America/Guyana, Etc/GMT+4,

America/Virgin, SystemV/AST4

America/Guayaquil, America/Eirunepe,

America/Lima, Etc/GMT+5

America/Belize, America/El_Salvador,

America/Tegucigalpa, Pacific/Galapagos,

Etc/GMT+6

Etc/GMT+7

Etc/GMT+8

Pacific/Gambier, Etc/GMT+9, SystemV/YST9

Pacific/Rarotonga, Pacific/Tahiti, Pacific/Fakaofo,

Pacific/Johnston, Pacific/Honolulu, Etc/GMT+10,

HST, US/Hawaii, SystemV/HST10

Pacific/Niue, Pacific/Pago_Pago, Pacific/Apia,

Pacific/Midway, Etc/GMT+11, Pacific/Samoa,

US/Samoa

Africa/Algiers, Africa/Luanda, Africa/Porto-Novo,

Africa/Douala, Africa/Bangui, Africa/Ndjamena,

Africa/Kinshasa, Africa/Brazzaville, Africa/Malabo,

Africa/Libreville, Africa/Windhoek, Africa/Niamey,

Africa/Lagos, Etc/GMT-1

Africa/Gaborone, Africa/Bujumbura,

Africa/Lubumbashi, Africa/Tripoli, Africa/Blantyre,

Africa/Maputo, Africa/Kigali, Africa/Lusaka,

Africa/Harare, Etc/GMT-2, Libya

Indian/Comoro, Africa/Djibouti, Africa/Asmera,

Africa/Addis_Ababa, Africa/Nairobi,

Indian/Antananarivo, Indian/Mayotte,

Africa/Mogadishu, Africa/Khartoum,

Africa/Dar_es_Salaam, Africa/Kampala,

Antarctica/Syowa, Asia/Bahrain, Asia/Kuwait,

Page 148

UCT-4

UCT-5

UCT-5:45

UCT-6

UCT-6:30

UCT-7

UCT-8

UCT-9

UCT-9:30

UCT-10

UCT-11

UCT-11:30

UCT-12

UCT-13

JST

KST

UCT-3:30

UCT-4:30

IST-2IDT

CST6MEX

CST6

EET-2EETDST2

EET-2EETDST3

EET-2EETDST2W2K

UCT-14

UCT9:30

IES-0883 User Manual

Asia/Qatar, Asia/Riyadh, Asia/Aden, Etc/GMT-3

Indian/Mauritius, Indian/Reunion, Indian/Mahe,

Asia/Muscat, Etc/GMT-4

Indian/Kerguelen, Indian/Maldives, Asia/Karachi,

Asia/Dushanbe, Asia/Ashgabat, Asia/Samarkand,

Asia/Tashkent, Etc/GMT-5

Asia/Katmandu

Antarctica/Mawson, Antarctica/Vostok, Asia/Dhaka,

Asia/Thimphu, Indian/Chagos, Asia/Colombo,

Etc/GMT-6, Asia/Dacca, Asia/Thimbu

Asia/Rangoon, Indian/Cocos

Antarctica/Davis, Asia/Phnom_Penh, Asia/Jakarta,

Asia/Pontianak, Asia/Vientiane, Asia/Bangkok,

Asia/Saigon, Indian/Christmas, Etc/GMT-7

Antarctica/Casey, Asia/Brunei, Asia/Taipei,

Asia/Makassar, Asia/Manila, Asia/Singapore,

Etc/GMT-8, Asia/Ujung_Pandang, Singapore

Asia/Dili, Asia/Jayapura, Pacific/Palau, Etc/GMT-9

Australia/Darwin, Australia/North

Antarctica/DumontDUrville, Pacific/Guam,

Pacific/Saipan, Pacific/Truk, Pacific/Noumea,

Pacific/Port_Moresby, Etc/GMT-10, Pacific/Yap

Pacific/Ponape, Pacific/Kosrae, Pacific/Guadalcanal,

Etc/GMT-11

Pacific/Norfolk

Pacific/Fiji, Pacific/Tarawa, Pacific/Enderbury,

Pacific/Majuro, Pacific/Kwajalein, Pacific/Nauru,

Pacific/Tongatapu, Pacific/Funafuti, Pacific/Wake,

Pacific/Efate, Pacific/Wallis, Etc/GMT-12, Kwajalein

Etc/GMT-13

Asia/Tokyo, Japan

Asia/Seoul, Asia/Pyongyang, ROK

Asia/Tehran, Iran

Asia/Kabul

Asia/Jerusalem, Asia/Gaza, Asia/Tel_Aviv, Israel

America/Cancun, America/Merida,

America/Monterrey, America/Mexico_City,

America/Lima, Mexico/General

America/Regina, America/Swift_Current,

Canada/East-Saskatchewan, Canada/Saskatchewan,

SystemV/CST6

Europe/Bucharest

Europe/Tallinn, Europe/Helsinki, Europe/Riga,

Europe/Mariehamn

Europe/Istanbul

Pacific/Kiritimati, Etc/GMT-14

Pacific/Marquesas

Page 149

UCT12

North America (Canada)

PST8PDT_CA

MST7MDT_CA

CST6CDT_CA

EST5EDT_CA

AST4ADT_CA

Etc/GMT+12

America/Vancouver, America/Dawson_Creek,

America/Whitehorse, America/Dawson,

Canada/Pacific

America/Edmonton, America/Yellowknife,

America/Inuvik, Canada/Mountain

America/Rainy_River, America/Winnipeg,

America/Rankin_Inlet, Canada/Central

America/Montreal, America/Toronto,

America/Thunder_Bay, America/Nipigon,

America/Iqaluit, Canada/Eastern

America/Goose_Bay, America/Halifax,

America/Glace_Bay, Canada/Atlantic

North America (Cuba)

EST5EDT_CU

North America (Haiti)

EST5EDT_HT

America/Havana, Cuba

America/Nassau, America/Santo_Domingo,

America/Port-au-Prince, America/Bogota

North America (Mexico)

PST8PDT_MX

MST7MDT_MX

CST6CDT_MX

North America (Turks and Caicos)

EST5EDT_TC

Additions Since 10g RTM

EST5EDT_INDIANA

America/Tijuana, America/Ensenada,

Mexico/BajaNorte

America/Chihuahua, America/Hermosillo,

America/Mazatlan, Mexico/BajaSur

America/Guatemala

America/Grand_Turk

America/Indiana/Indianapolis,

America/Indiana/Marengo, America/Indiana/Vevay,

America/Fort_Wayne, America/Indianapolis,

America/Indiana/Knox, America/Knox_IN,

US/Indiana-Starke, US/East-Indiana

Australia/Perth, Australia/West UCT-8_WA

IES-0883 User Manual Page 150

IES-0883 User Manual Page 151

advertisement

Related manuals

Download PDF

advertisement

Table of contents