M H L 1 . 2 S O L U T I O N S T P A – M H L – 8

M H L  1 . 2 S O L U T I O N S    T P A – M H L – 8
TPA–MHL–8R
TEST POINT ADAPTER FOR MHL 1.2 DEVICES
MHL 1.2 SOLUTIONS
Mobile High-Definition Link (MHL) is a video interface derived from
980 MHL CBUS COMPLIANCE TEST MODULE
HDMI but targeted to provide an interface from mobile devices like
980 MHL
CBUS
MODULE
smart
phones
to TVsCOMPLIANCE
or other displays.TEST
The MHL
standard is designed
980
MHL
CBUS
COMPLIANCE
TEST
MODULE
to connect to smart phones by reusing the existing
5 pin micro-USB
980 MHLthat
CBUS
TEST
connector
manyCOMPLIANCE
phones have rather
thanMODULE
requiring a separate 19
pin
HDMI
The MHL cable isTEST
micro-USB
on the source
980
MHLconnector.
CBUS COMPLIANCE
MODULE
mobile
device
and
HDMI Type ATEST
on the
other end.
980 MHL
CBUS
COMPLIANCE
MODULE
Functional testing of MHL 1.2 sources
Conduct basic verification testing of MHL 1.2 source devices
using the TPA-MHL-8R and a standard HDMI HDTV.
Quantum Data offers a comprehensive suite of test solutions for
testing MHL 1.2 source, sink and dongle devices. The centerpiece of
these solutions is the test point adapter (TPA-MHL-8R) that converts
MHL 1.2 streams to HDMI and HDMI streams to MHL. The TPA-MHL8R enables basic emulation, functional testing, protocol analysis as
well as MHL compliance testing and HDCP compliance testing.
Protocol analysis and MHL compliance testing requires the Quantum
Data 980 Protocol Analyzer. HDCP compliance testing requires the
Quantum Data 882EA.
MHL protocol analysis for MHL 1.2 source devices
View details of MHL protocol data from MHL 1.2 source
device. Monitor MHL metadata in real time or capture and
store for analysis. Requires TPA-MHL-8R, Quantum Data 980
Protocol Analyzer 297MHz “Gen 3“.
Note: There is a new Test Point Adapter (TPA-MHL2-8R) for MHL 2.0 testing.
MHL compliance testing for MHL 1.2 source devices
Run MHL compliance tests on MHL 1.2 source devices in
accordance with Section 3 of the MHL compliance Test
Specification. Requires TPA-MHL-8R, Quantum Data 980
Protocol Analyzer 297MHz “Gen 3“, and MHL source
compliance option.
Basic Protocol Testing of MHL 1.2 sources
Conduct basic protocol testing of MHL 1.2 source devices
using the TPA-MHL-8R and HDMI Protocol tester such as the
Quantum Data 780 Handheld Test Instrument.
HDCP compliance testing for MHL 1.2 source devices
Run HDCP compliance tests on MHL 1.2 source device in
accordance with the HDCP 1.2 Compliance Test Specification.
Requires TPA-MHL-8R, Quantum Data 882EA, and HDCP
compliance option.
MHL C-Bus monitoring between MHL 1.2 source and sink
devices
View details of MHL C-Bus transactions. Monitor in real time
or capture and store for analysis. Requires TPA-MHL-8R,
Quantum Data 980 Protocol Analyzer 297MHz “Gen 3“.
Functional testing of MHL 1.2 sink devices
Conduct basic verification testing of MHL-capable display
devices using the TPA-MHL-8R and a standard HDMI source
such as Quantum Data 882E or 780 Handheld Test
Instrument.
MHL compliance testing for MHL 1.2 sink/dongle devices
Run MHL compliance tests on MHL 1.2 sink/dongle devices in
accordance with Sections 4 and 5 of the MHL compliance
Test Specification. Requires TPA-MHL-8R, Quantum Data
882EA, and MHL sink compliance option.
HDCP compliance testing for MHL 1.2 sink/dongle devices
Run HDCP compliance tests on MHL 1.2 sink/dongle devices
in accordance with the HDCP 1.2 Compliance Test
Specification. Requires TPA-MHL-8R, Quantum Data 882EA,
and HDCP compliance option.
Rev. A3 – 12/12/12
100-
Quantum Data, Inc.
-
2111 Big Timber Road Elgin, IL
-
Phone 847-888-0450
-
www.quantumdata.com
TPA-MHL-8R – TEST POINT ADAPTER
COMPLIANCE TEST MODULE
SPECIFICATIONS
General Specifications
Size (mm)
Width: 8-1/2 in (21.59cm)
Depth: 3-7/8in (9.82cm)
Height: 1-7/8in (4.76cm)
Weight (kg)
1.58lbs (718 grams)
Humidity
30% to 80% RH non condensing
Power
AC Mains
Frequency
Voltage
50 to 60Hz
100 to 240VAC  12VDC output
TPA-MHL-8R Rear
Section
Connector Label
Applications
Connection
980 CONNECTIONS
SOURCE DUT
OUT TO 980 PORT 1
Protocol Analysis for MHL 1.2 source
devices. Uses 980 Protocol Analyzer.
Connect MHL cable to MHL mobile device (MHL
source).
MHL IN FROM DUT
Protocol compliance testing for MHL 1.2
source devices. Uses 980 Protocol Analyzer.
Connect HDMI cable to the Rx port on 980 MHL
Protocol Analyzer.
HDMI OUT
Basic functional testing of an MHL source An HDMI cable is connected to the HDMI IN
port on an HDTV to monitor the video and
audio.
This is an HDMI output. The device it gets connected
to depends on the source test application.
882 CONNECTIONS
SOURCE DUT
Basic protocol testing of an MHL source.
Uses the 882EA or 780 to check the timing
and protocol data or to check the response to
various EDIDs.
HDCP compliance testing of an MHL 1.2
source. Uses 882EA and EST device.
MHL IN FROM DUT
882 CONNECTIONS
SINK DUT
HDMI IN
MHL OUT TO DUT
MHL IN FROM
SOURCE

For basic protocol testing of an MHL source – An
HDMI cable is connected to an HDMI input on the
882EA or 780 to check the timing and protocol
data or to check the response to various EDIDs.

For HDCP compliance testing of an MHL source –
An HDMI cable is connected to a port on the
Encryption Status Tester (EST).
HDCP compliance testing of an MHL 1.2
sink. Uses Quantum Data 882EA and EST
device.
CBUS Passive monitoring with 980 Protocol
Analyzer.
Connect HDMI cable from HDMI out of 882EA and
EST device.
Connect MHL cable to the MHL 1.2 sink device under
test, e.g. HDTV.
Connect MHL cable from MHL 1.2 source device under
test, e.g. mobile phone.
MHL OUT TO SINK
Connect MHL cable to the MHL 1.2 sink device under
test, e.g. HDTV.
TO 980 TRIGGER IN
CBUS
Connect coax cable to TRIG IN port on 980 Protocol
Analyzer.
DC POWER 12V
Quantum Data, Inc.
For basic functional testing of an MHL source - An
HDMI cable is connected to the HDMI IN port on
an HDTV to monitor the video and audio.
Connect MHL cable from MHL source device under
test, e.g. mobile phone.
Protocol compliance test of an MHL 1.2 sink.
Uses 882EA and 980 Protocol Analyzer.
980 CONNECTIONS
CBUS ANALYSIS

Not applicable
-
2111 Big Timber Road Elgin, IL
Connects to 12V DC power adapter.
-
Phone 847-888-0450
-
www.quantumdata.com
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement