FortiAnalyzer Unit LED Indicators
Light Icon Description
The light flashes orange when packets are sent and received on the Ethernet port.
Power indicator is blue when the FortiAnalyzer system is on.
Hard Disk Upper LED
Hard Disk Lower LED
The light flashes blue when reading the boot device.
Blue when the hard disk is properly inserted into the drive bay and the FortiAnalyzer is plugged in to a power source.
Flashes blue when reading and writing to the hard disk.
2000A
PS RST
2 1
POWER
ACTIVITY
DISK DRIVE LEGEND
HDD 1 (P0)
HDD 2 (P1)
HDD 3 (P2)
HDD 4 (P3)
HDD 5 (P4)
HDD 6 (P5)
FortiAnalyzer-2000A
© Copyright 2008 Fortinet Incorporated. All rights reserved.
Products mentioned in this document are trademarks or registered trademarks of their respective holders.
Regulatory Compliance
FCC Class A Part 15 CSA/CUS
18 March 2008
05-30006-0352-20080318
2000A
LED indicators:
Power, Error, Network Access
Front
Power Supply Alarm ResetButton
Power Button
PS RST
2 1
DISK DRIVE LEGEND
HDD 1 (P0)
HDD 2 (P1)
HDD 3 (P2)
HDD 4 (P3)
HDD 5 (P4)
HDD 6 (P5)
POWER
ACTIVITY
Power
Connections
Back
Connector
Ports 1 and 2
CONSOLE
Orange - Crossover
Grey - Straight-through
Type Speed
RJ-45 10/100/1000 Base-T
DB-9 9600 bps
USB ports for future use
DB9 Serial
Connection
Ethernet
Connections
Null-Modem Cable
(RS-232)
Power Cable
2000A
Q u i c k S t a r t G u i d e
PS RST
FortiAnalyzer-2000A
Copyright 2008 Fortinet Incorporated. All rights reserved.
Trademarks
Products mentioned in this document are trademarks.
Documentation
Protocol Description
Ethernet Connection to the network
RS-232 Connection to the management computer. Provides access to the command line interface
(CLI).
Connect the FortiAnalyzer unit to a power outlet and to the network hub or switch.
• Insert the hard disks included in the FortiAnalyzer package into the bays of the
FortiAnalyzer unit, starting in bay 1. Use the diagram on the front panel as a guide.
• Place the FortiAnalyzer unit on a stable surface. It requires 1.5 inches (3.75 cm) clearance on each side to allow for cooling.
• Insert a network cable to port 1. Insert the other end to the router or switch connected to the network.
• Connect one power chord to a power supply. Connect the other power cord to an alternate power source if available.
• Connect the Power Cord to a surge protected power bar or power supply.
• Press the Power button to turn on the FortiAnalyzer unit.
• The power LED appears blue and the hard disk icon LED flashes blue while the system boots.
•
• For more information, see the FortiAnalyzer Install Guide.
Power connections
Null modem cable connects to serial port on management computer.
Straight-through Ethernet cable connects to hub or switch on the network.
You can add the FortiAnalyzer unit to your local FortiGate network to receive log messages from your local FortiGate units, or connect the FortiAnalyzer unit to the FortiGate units remotely using FortiManager. To connect the FortiAnalyzer unit to the FortiGate units remotely, you must configure the DNS server and the default gateway.
To manage the FortiAnalyzer unit, you can use a computer within the local network or over the Internet.
Factory Defaults
Administrator Account
Port 1
Port 2
User name:
Password:
IP:
Netmask:
Management Access:
IP:
Netmask:
Management Access: admin
(none)
192.168.1.99
255.255.255.0
ping, https, http, ssh
192.168.2.99
255.255.255.0
ping, https, http, ssh
Web-based manager
The FortiAnalyzer web-based manager is an easy to use management tool.
Use it to configure the administrator password, the interface and default gateway addresses, and the DNS server addresses.
Requirements:
• An Ethernet connection between the FortiAnalyzer unit and management computer.
• Internet Explorer 6.0 or higher on the management computer.
Command Line Interface (CLI)
The CLI is a full-featured management tool. Use it to configure the administrator password, the interface addresses, the default gateway address, and the DNS server addresses. To configure advanced settings, see the Tools and Documentation CD-ROM.
Requirements:
• An DB-9 serial connection between the FortiAnalyzer unit and management computer.
• A terminal emulation application (HyperTerminal for Windows) on the management computer.
Web-based Manager
Use the following procedure to connect to the web-based manager for the first time. Configuration changes made with the web-based manager are effective immediately without resetting the FortiAnalyzer unit or interrupting service.
To connect to the web-based manager
1. Connect the Port 1 interface of the FortiAnalyzer unit to Ethernet port of the management computer.
Use a cross-over Ethernet cable to connect the devices directly. Use straight-through
Ethernet cables to connect the devices through a hub or switch.
2. Configure the management computer to be on the same subnet as the FortiAnalyzer
LAN interface.
To do this, change the IP address of the management computer to 192.168.1.2 and the netmask to 255.255.255.0.
3. To access the FortiAnalyzer web-based manager, in your browser, go to https://192.168.1.99 (remember to include the “s” in https://).
4. Type admin in the Name field and select Login.
After connecting to the Web-based manager, you can configure the FortiAnalyzer unit IP address, DNS server IP address, and default gateway to connect the FortiAnalyzer unit to the network.
To configure interfaces
1. Go to System > Network > Interface.
2. Select the edit icon for each interface to configure.
3. Set the IP address and netmask for the interface.
4. Select OK.
To configure the Primary and Secondary DNS server IP addresses
1. Go to System > Network > DNS, enter the Primary and Secondary DNS IP addresses select Apply.
To configure a Default Gateway
1. Go to System > Network > Routing and select Create New.
2. Set Gateway to the Default Gateway IP address and select OK.
Command Line Interface
The FortiAnalyzer-2000A has an DB-9 console port. Use the DB-9 cable to connect it to your management computer.
To connect to the FortiAnalyzer unit
1. Use a DB-9 cable to connect the FortiAnalyzer serial port to the management computer serial port.
2. Start a terminal emulation program (such as HyperTerminal) on the management computer. Use these settings: Baud Rate 9600, Data bits 8, Parity None, Stop bits 1, Flow
Control None.
3. At the login: prompt, type admin and press Enter twice.
(The login prompt is preceded by the server default host name.)
After connecting to the CLI, you can configure the FortiAnalyzer unit IP address, DNS server
IP address, and default gateway to connect the FortiAnalyzer unit to the network.
To configure the FortiAnalyzer unit using the CLI
1. Set the IP address and netmask of the Port1 interface. config system interface
edit port1
set ip <intf_ip>/<netmask_ip> end
3. Configure the primary and secondary DNS server IP addresses.
config system dns
set primary <dns-server_ip>
set secondary <dns-server_ip> end
4. Configure the default gateway.
config system route
edit 1
set device <interface>
set dst <destination_ip>
set gateway <gateway_ip> end
Adding an administration password
By default, the admin user does not have a password. To restrict access to the FortiAnalyzer unit management account, add password for the admin user account.
To add the admin user account password
1. Go to System > Admin.
2. For the admin user, select the Change Password icon.
3. Enter a new password in the New Password box.
4. Reenter the password to Confirm Password box.
5. Select OK.
Adding an administration password using the CLI
To add an administration password in the CLI enter the following commands: config system settings edit admin set password <password> end
Shutting down the FortiAnalyzer unit
When powering off the FortiAnalyzer unit, always shut down the unit using the following procedures before disconnecting the power supply. Not following this procedure can increase the risk of damaging the FortiAnalyzer hard disk.
To power off the FortiAnalyzer unit
1. Go to System > Dashboard.
2. In the System Operation list, select Shut Down.
3. Select Go.
4. Once the indicates the shut down procedure has completed, disconnect the
FortiAnalyzer unit from the power source.
Shutting down the FortiAnalyzer unit using the CLI
Enter the following command at the prompt: execute shutdown
Congratulations!
You have finished configuring the basic settings. You are ready to add FortiGate devices and collect log information. To explore the full range of configuration options, see the online help or the Tools and Documentation CD-ROM.
Visit these links for more information and documentation for your Fortinet product.
• Technical Documentation - http://docs.forticare.com
• Fortinet Knowledge Center - http://kc.forticare.com
• Fortinet Technical Support - http://support.fortinet.com