Jetzt herunterladen
Technische Daten | Technical specifications:
KDG Klassifizierung
KDG classification
Frequenzbereich
Frequency range
Verstärkung
Gain
Einstellbarer Dämpfungssteller
Adjustable attenuator (DS 1)
Einstellbarer Leitungsentzerrer
Adjustable equalizer (DS 2)
Dämpfung (Interstage)
Attenuation (Interstage) (DS J1)
Entzerrung (Interstage)
Equalization (Interstage) (DS J2)
Ausgangspegel
Output level
Rauschmaß
Noise figure
Rückkanal, aktiv
Return path, active
Rückkanalverstärkung
Return path gain
Dämpfungssteller für Rückkanal
Attenuator for return path (US)
Dämpfung (Interstage)
Attenuation (Interstage) (US J2)
Entzerrung (Interstage)
Equalization (Interstage) (US J1)
Rückflussdämpfung
Return loss
Rauschmaß
Noise figure
Schaltnetzteil
Switching mode power supply
Leistungsaufnahme
Power consumption
HF-Anschlüsse
RF Connectors
Messbuchse eingangsseitig, bidirektional
Test port input, bi-directional
Messbuchse ausgangsseitig, unidirektional
Test port output, uni-directional
Maße ca.
Dimensions appr.
1
gem. KDG 1 TS140
2
CENELEC Raster 42 ch. 60dB IMA
C (4.3)1
85…1006 MHz
38 dB
15 dB
15 dB
0/2/4/6 dB
0/2/4/6 dB
107 dBµV (CSO/CTB2)
<5,5 dB
5…65 MHz
Dieses Symbol weist darauf hin, dass das Produkt gemäß WEEE-Richtlinie
(Richtlinie über Elektro- und Elektronik-Altgeräte) (2002/96/EC) und
nationalen Gesetzen nicht über den Hausmüll entsorgt werden darf.
Dieses Produkt muss bei einer dafür vorgesehenen Sammelstelle
abgegeben werden. Dies kann z. B. durch Rückgabe beim Kauf eines
ähnlichen Produkts oder durch Abgabe bei einer autorisierten Sammelstelle
für die Wiederaufbereitung von Elektro- und Elektronik-Altgeräten
geschehen.
Informationen zu Sammelstellen für Altgeräte erhalten Sie bei Ihrer
Stadtverwaltung, dem öffentlich-rechtlichen Entsorgungsträger, einer
autorisierten Stelle für die Entsorgung von Elektro- und ElektronikAltgeräten oder Ihrer Müllabfuhr.
This symbol indicates that this product is not to be disposed of with your
household waste, according to the WEEE Directive (2002/96/EC) and your
national law.
This product should be handed over to a designated collection point, e.g.,
on an authorized one-for-one basis when you buy a new similar product or
to an authorized collection site for recycling waste electrical and electronic
equipment (WEEE).
For more information about where you can drop off your waste equipment
for recycling, please contact your local city office, waste authority, approved
WEEE scheme or your household waste disposal service.
30 dB
15 dB
0/6 dB
0/3/6/9 dB
18 dB (-1,5 dB/Okt.)
80...250 V~
47...63 Hz
10 W
-20dB
-20dB
195 × 90 × 55 mm
BETRIEBSANLEITUNG
BK-Hausanschlussverstärker
OPERATION INSTRUCTIONS
CATV Distribution Amplifier
Safety advice:
<5,5 dB
F
Sicherheitshinweise:
Die Installation des Geräts und Reparaturen am Gerät sind ausschließlich vom Fachmann unter
Beachtung der geltenden VDE-Richtlinien durchzuführen. Bei nicht fachgerechter Installation und
Inbetriebnahme wird keine Haftung übernommen.
Vor Öffnen des Gerätes Netzstecker ziehen bzw. Stromzuführung entfernen, andernfalls besteht
Lebensgefahr. Dies gilt auch, wenn Sie das Gerät reinigen oder an den Anschlüssen arbeiten.
Verwenden Sie nur das am Gerät angeschlossene Netzkabel. Es dürfen am Netzkabel auf keinen Fall
Teile ausgetauscht oder Veränderungen vorgenommen werden. Es besteht sonst Lebensgefahr, für die
keine Haftung übernommen wird.
Sofern eine austauschbare Sicherung vorhanden ist, ist vor dem Wechsel der Sicherung der
Netzstecker zu ziehen. Defekte Sicherungen nur durch normgerechte Sicherungen des gleichen
Nennwertes ersetzen.
Das Gerät darf nur in trockenen Räumen betrieben werden. In feuchten Räumen oder im Freien
besteht die Gefahr von Kurzschlüssen (Achtung: Brandgefahr) oder elektrischem Schlägen (Achtung:
Lebensgefahr).
Um Beschädigungen am Gerät selbst oder an Peripheriegeräten vorzubeugen, dürfen Geräte, die zur
Wandmontage vorgesehen sind nur auf flachen Oberflächen montiert werden.
Planen Sie den Montage- bzw. Aufstellort so, dass Sie in Gefahrensituationen den Netzstecker leicht
erreichen und aus der Steckdose ziehen können. Wählen Sie den Montage- bzw. Aufstellort so, dass
Kinder nicht unbeaufsichtigt am Gerät und dessen Anschlüssen spielen können. Der Montage- bzw.
Aufstellort muss eine sichere Verlegung aller angeschlossenen Kabel ermöglichen. Das Netzkabel
sowie Zuführungskabel dürfen nicht durch irgendwelche Gegenstände beschädigt oder gequetscht
werden.
Wählen Sie einen Montage- bzw. Aufstellungsort, an dem unter keinen Umständen Flüssigkeiten oder
Gegenstände in das Gerät gelangen können (z. B. Kondenswasser, Dachundichtigkeiten, Gießwasser
etc.)
Setzen Sie das Gerät niemals direkter Sonneneinstrahlung aus und vermeiden Sie die direkte Nähe
von Wärrmequellen (z. B. Heizkörper, andere Elektrogeräte, Kamin etc.) Bei Geräten, die Kühlkörper
oder Lüftungsschlitze haben, muss daher unbedingt darauf geachtet werden, dass diese keinesfalls
abgedeckt oder verbaut werden. Sorgen Sie außerdem für eine großzügig bemessene Luftzirkulation
um das Gerät. Damit verhindern Sie mögliche Schäden am Gerät sowie Brandgefahr durch
Überhitzung. Achten Sie unbedingt darauf, dass Kabel nicht in die Nähe von Wärmequellen (z.B.
Heizkörper, andere Elektrogeräte, Kamin etc.) kommen.
Ihr Gerät trägt das CE-Zeichen und erfüllt alle erforderlichen EU-Normen.
Änderungen und Druckfehler vorbehalten. Stand 03/13. Abschrift und
Vervielfältigung nur mit Genehmigung des Herausgebers. TechniSat sind
eingetragene Warenzeichen der TechniSat Digital GmbH
Postfach 560
54541 Daun
www.technisat.de
Technische Hotline
Mo. - Sa.: 08.00 - 20.00 Uhr:
Tel. 03925 9220 1800
Achtung !
Sollte es mit diesem Gerät zu einem Problem kommen,
wenden Sie sich bitte zunächst an unsere Technische Hotline.
Für eine evtentuell erforderliche Einsendung des Gerätes
verwenden Sie bitte ausschließlich folgende Anschrift:
TechniSat Teledigital GmbH
Service-Center
Nordstr. 4a39418 Staßfurt
Stand 2014-10-08 - Konstruktions und Typenänderung vorbehalten keine Haftung für Druckfehler
State of the art 2014-10-08 - Reserving change in design and type - We cannot be held liable for printing errors
Installation and repairs to the equipment may only be carried out by technicians observing the current
VDE guidelines. No liability will be assumed in the case of faulty installation and commissioning.
Before opening the equipment pull out the power plug or remove the power supply, otherwise there is
danger of electrocution. This is also valid for cleaning the equipment or working on the connections.
Only use the mains cable connected to the device. Never replace any parts or make any modifications
on the mains cable. Otherwise there is a risk of mortal injury for which we cannot be held liable.
Providing that a serviceable fuse exists, the power plug must be pulled out before changing the fuse.
Defective fuses may only be replaced with standard compliant fuses that have the same nominal
value.
The equipment may only be operated in dry rooms. In humid rooms or outdoors there is danger of
short-circuit (caution: risk of fire) or electrocution.
To prevent damage to your equipment and to avoid possible peripheral damages, the devices foreseen
for wall mounting may only be installed on a flat surface.
Choose the location of installation or mounting so that the power plug can be reached and pulled out of
the socket easily in case of danger. Choose the location of installation or mounting such that children
may not play unsupervised near the equipment and its connections. The location of installation or
mounting must allow a safe installation of all cables connected. The mains cable as well as feeder lines
may not be damaged or clamped by objects of any kind.
Choose the location of installation or mounting so that under no circumstances liquids or objects can
get into the equipment (e.g. condensation, water coming from leaking roofs or flowing water, etc.).
Avoid exposure of the equipment to direct sunlight and to other heat sources (e. g. radiators. other
electrical devices, chimney, etc.). Devices that are equipped with heat sinks or ventilation slots must
under no circum-stances be covered or blocked. Also ensure for a generous air circulation around the
equipment. In this way you avoid possible damage to the equipment as well as a risk of fire caused by
overheating. Absolutely avoid that cables come near any source of heat (e.g. radioators, other
electrical devices, chimney, etc.).
Verwendungsbereich:
Erdung und Montage:
Die Geräte sind ausschließlich für den Einsatz zum Verstärken sowie Verteilen
von Radio- und Fernsehsignalen im Haus geeignet! Wird das Gerät für andere
Einsätze verwendet, wird keine Garantie übernommen!
Die Abbildungen zeigen Anwendungsbeispiele für die Verteilung in Sternstruktur
(1) bzw. Baumstruktur (2).
Field of application:
The devices are only suitable for in-house distribution of RF signals! If the device
is used for other purposes, no warranty is given!
The illustrations show application examples of the distribution in star (1) or tree
structure (2).
Zur Vermeidung gefährlicher Überspannungen (Achtung: Brand-/Lebensgefahr),
müssen die Geräte geerdet werden. Verwenden Sie die am Gerät angebrachte
Erdungsklemme (3).
Verwenden Sie die dem Gerät beiliegenden Montageschrauben und die
Montagelöcher an den Geräten (4).
DS J1
DS 1
Grounding and Mounting:
DS J2
DS J2
DS J1
DS 2
To avoid dangerous power surges (e.g. risk of fire and danger of life) all devices
must be grounded. Use the screw terminal at the device (3).
Use the included mounting screws and the mounting holes of the devices (4).
US
US J1
US J2
DS 1
DS 2
US
US J1
US J2
1
4
4
3
Upstream
2
Downstream
Eingang/Input
Ausgang/Output
Messbuchsen
Test ports
Upstream
Downstream
Hinweis: Wegen des Rückkanals von 5...65 MHz ist kein Empfang von VHF I im
Vorwärtsweg möglich.
Note: Because of the return path of 5...65 MHz VHF I cannot be received in the
forward path.
HF-Anschluss:
Schließen Sie den Eingang des Verstärkers am Hausübergabepunkt an.
Verbinden Sie den Ausgang des Verstärkers mit den verwendeten
Antennensteckdosen oder Abzweigern.
Verwenden Sie hierfür ein hochgeschirmtes Koaxialkabel mit einem FAnschlussstecker. Passende Kabel und Stecker finden Sie
unter www.technisat.de
Die Messbuchse am Eingang ist bi-direktional ausgelegt. Diese Messbuchse
muss deshalb zur Messung mittels des Jumpers ein- bzw. ausgeschaltet
werden.
RF Installation:
Connect the input of the amplifier to the interconnection point. Connect the
output of the amplifier to the antenna sockets or the taps used.
Use a highly shielded coaxial cable with an F connector. Suitable cables and
connectors see www.technisat.de
The test ports at the input is bi-directional. This test point has to be activated or
deactivated with the adjacent jumper.
Einstellungen von Dämpfung und Entzerrung:
Mit den Reglern (DS 1) und (DS 2) werden Dämpfung und Entzerrung im
Vorwärtsweg eingestellt mit dem Regler (US) wird die Dämpfung des
Rückkanals vor der Verstärkerstufe eingestellt.
Mit den Jumpern (DS J1 und DS J2) werden Interstage-Dämpfung und Entzerrung im Vorwärtsbereich eingestellt.
Mit den Jumpern (US J1 und US J2) werden Interstage-Entzerrung und Dämpfung im Rückkanal eingestellt.
Adjustments of gain and slope:
Gain and slope are adjusted (continuously variable) with the control buttons
(DS 1 and DS 2) in the forward frequency range.
With control button (US) one adjusts the gain (also continuously variable) of the
return path before the amplifier stage.
The jumpers (DS J1 and DS J2) are used to adjust the interstage attenuation
and slope in the forward frequency range.
The jumpers (US J1 and US J2) are used to adjust the interstage slope and
attenuation of the return path.