Technical Data Sheet

VNA Master

Handheld Vector Network Analyzer +

Spectrum Analyzer

MS2026C

5 kHz to 6 GHz

MS2036C

5 kHz to 6 GHz

9 kHz to 9 GHz

MS2027C

5 kHz to 15 GHz

MS2037C

5 kHz to 15 GHz

9 kHz to 15 GHz

MS2028C

5 kHz to 20 GHz Vector Network Analyzer

MS2038C

5 kHz to 20 GHz

9 kHz to 20 GHz

Vector Network Analyzer

Spectrum Analyzer

The Ultimate Handheld Vector Network + Spectrum Analyzer for

Cable, Antenna, and Signal Analysis Anytime, Anywhere

Introduction

High Performance Handheld S-Parameters — Meet the MS202xC/3xC VNA Master + Spectrum Analyzer, the industry’s broadest frequency handheld solution to address cable, antenna, component, and signal analysis needs in the field with frequency coverage from 5 kHz up to 20 GHz. Equally impressive, this broadband measurement tool offers the industry’s first 12-term error correction algorithm in a truly handheld, battery-operated, rugged multi-function instrument. Optional Time Domain with Low Pass Step response and Real Impedance graph delivers standard TDR-type display results. Time Domain also includes a standard gating function.

The MS203xC models include a powerful spectrum analyzer that multiplies user convenience by combining spectrum analysis with the VNA into a single measurement powerhouse for the harsh RF and physical environments of field test.

Whether it is for spectrum monitoring, broadcast proofing, interference analysis, RF and microwave measurements, regulatory compliance, or 3G/4G and wireless data network measurements, this VNA/Spectrum Analyzer combination is the ideal instrument for making fast and reliable measurements in the field.

VNA Master™ MS202xC/MS203xC Vector Network Analyzer + Spectrum Analyzer

Size: 315 mm x 211 mm x 78/97mm (12.4 in x 8.3 in x 3.1/3.8 in), Lightweight: 4.5 kg to 4.8 kg (9.9 lb to 10.5 lb)

Specifications VNA Master MS202xC/MS203xC

Vector Network Analyzer Performance and Functional Highlights (All Models)

Broadband coverage of 5 kHz to up to 20 GHz

True 2-path, 2-port Vector Network Analyzer

Ultimate accuracy with 12-term error correction

High Performance Handheld S-Parameters

User-defined Quad Display for viewing all 4 S-Parameters

Arbitrary data points up to 4001

IF Bandwidth selections of 10 Hz to 100 kHz

Directivity:

> 42 dB up to 6 GHz (all models)

> 36 dB > 6 GHz up to 20 GHz (all models)

Supports Reciprocal Through Calibration types

(SOLR, SSLR, SSSR)

All models support waveguide measurements

350 μs/data point sweep speed

USB/Ethernet for PC data transfer and control

Automate repetitive tasks via Ethernet & USB

Field upgradable firmware

Operation to +55 ºC: full performance on AC or battery

Store more than 4000 traces and setups in memory

Portable: 4.5/4.8 kg (9.9/10.5 lb)

Time Domain (with gating) option

Internal Bias Tee option

Vector Voltmeter option

High Accuracy Power Meter option

Differential option (S d1d1

, S

c1c1

, S

d1c1

, and S

c1d1

)

Secure Data Operation option for safe use in high security

environments

GPS Receiver option

Low Pass Stepped Response and Real Impedance graph type

provide TDR functionality (standard capability with

Time Domain option)

Multiple display formats including Polar and Real Impedance

Supports Anritsu USB Power Sensors

8.4 in, 800 x 600 high resolution, daylight-viewable TFT color

display

Complies with MIL-PRF-28800F Class 2, Certified for use in

Explosive Atmosphere per MIL-PRF-28800F and

MIL-STD-810G

Spectrum Analyzer Performance and Functional Highlights (MS203XC Models Only)

Measure: Occupied Bandwidth, Channel Power, ACPR, C/I

Dynamic Range: > 106 dB in 1 Hz RBW

DANL: –164 dBm in 1 Hz RBW

Phase Noise: –106 dBc/Hz @ 10 kHz offset at 1 GHz

GPS-Enhanced Frequency Accuracy: < ± 25 ppb with GPS On

and locked. GPS-Enhanced Frequency Accuracy is retained after GPS unlock at < 50 ppb for 72 hours, 0 °C to 50 °C

1 Hz to 10 MHz Resolution Bandwidth (RBW)

Traces: Normal, Max Hold, Min Hold, Average, # of Averages

Detectors: Peak, Negative, Sample, Quasi-peak, and true RMS

Markers: 6, each with a Delta Marker, or 1 Reference with

6 Deltas

Limit Lines: up to 40 segments with one-button

envelope creation

Trace Save-on-Event: crossing limit line or sweep complete

Option to automatically optimize sweep-RBW-VBW trade-off

for best possible display

Interference Analyzer Option: Spectrogram, Signal Strength,

RSSI

Standard Burst Detect: 1000X faster sweep with spans up to

15 MHz. Captures intermittent signals as narrow as 200

μ

S every time.

GPS tagging of stored traces

Internal Preamplifier standard

High Accuracy Power Meter Option

AM/FM/SSB Demodulation (audio only)

Optional AM/FM/PM Analyzer

Optional Coverage Mapping

Optional Channel Scanner

2 of 32

PN: 11410-00548 Rev. R MS202xC/MS203xC TDS

VNA Master MS202xC/MS203xC Specifications

Table of Contents

Vector Network Analyzer Performance and Functional Highlights (All Models). . . . . . . . . . . . . . . . 2

Spectrum Analyzer Performance and Functional Highlights (MS203XC Models Only) . . . . . . . . . . . 2

Definitions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

VNA Performance Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

VNA Functional Specifications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

Corrected System Performance and Uncertainties — High Port Power . . . . . . . . . . . . . . . . . . . . . 6

Distance Domain Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10

Time Domain (Option 2) Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10

Option Comparison Table (Distance Domain and Time Domain) . . . . . . . . . . . . . . . . . . . . . . . . 10

Secure Data Operation (Option 7) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10

Bias Tee (Option 10) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11

Balanced/Differential S-Parameters, 1-Port (Option 77) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11

Vector Voltmeter (Option 15) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11

Spectrum Analyzer Performance Specifications (MS203xC only) . . . . . . . . . . . . . . . . . . . . . . . . 12

High Accuracy Power Meter (Option 19) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14

Interference Analyzer (Option 25) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14

Channel Scanner (Option 27) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14

Coverage Mapping (Option 431) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15

GPS Receiver (Option 31) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15

AM/FM/PM Signal Analyzer (Option 509, MS203xC only) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16

General Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17

Line Sweep Tools™ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19

Master Software Tools. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19

Master Software Tools. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20

Ordering Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21

Standard Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21

Optional Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22

Definitions

All specifications and characteristics apply to Revision 2 instruments under the following conditions, unless otherwise stated:

Warm-Up Time After 15 minutes of warm-up time in VNA mode, where the instrument is left in the ON state.

Temperature Range Over the 23 °C ± 5 °C temperature range.

Reference Signal When using internal reference signal.

Spectrum Analyzer After 5 minutes of warm-up time, where the instrument is left in the ON state and

Sweep Mode set to Performance.

Typical Performance Typical specifications that are not in parenthesis are not tested and not warranted. They are generally representative of characteristic performance. Typical specifications in parenthesis ( ) represent the mean value of measured units and do not include any guard-bands or uncertainties. They are not warranted.

Uncertainty A coverage factor of x1 is applied to the "VNA" or "corrected system" measurement uncertainties to facilitate comparison with other industry handheld analyzers.

Calibration Cycle Calibration is within the recommended 12 month period (residual specifications also require calibration kit calibration cycle adherence.)

All specifications subject to change without notice. For the most current data sheet, please visit the Anritsu web site: www.anritsu.com

MS202xC/MS203xC TDS PN: 11410-00548 Rev. R

3 of 32

Specifications VNA Master MS202xC/MS203xC

VNA Performance Specifications

Block Diagram

As shown in the following simplified block diagram, the VNA Master has a 2-port, 2-path architecture that automatically measures four S-parameters with a single connection.

Port 1 S

21

Port 2

S

11

DUT

S

22

S

12

Receiver

Port 1

Receiver

Port 2

Bridge/

Coupler

Reference

Receiver

Bridge/

Coupler

Switch

Source

Frequency

Frequency Range MS2026C/36C: 5 kHz to 6 GHz

MS2027C/37C: 5 kHz to 15 GHz

MS2028C/38C: 5 kHz to 20 GHz

Frequency Accuracy ±1.5 ppm

Frequency Resolution 1 Hz to 375 MHz, 10 Hz to 6 GHz, and 100 Hz to 20 GHz

Test Port Power

typical

VNA Master supports selection of either High (default) or Low test port power. Changing power after calibration can degrade the calibrated performance.

Frequency Range High Port Power (dBm) Low Port Power (dBm)

5 kHz to 3 GHz

> 3 GHz to 6 GHz

> 6 GHz to 20 GHz

+3

–3

–3

–25

–25

–15

Transmission Dynamic Range

The transmission dynamic range (the difference between test port power and noise floor) using 10 Hz IF Bandwidth and High Port Power:

Frequency Range

5 kHz to 2 MHz 85 dB

> 2 MHz to 3 GHz 100 dB

> 3 GHz to 6 GHz 90 dB

> 6 GHz to 20 GHz 85 dB

Sweep Speed

The typical sweep speed in μs/point for IF Bandwidth of 100 kHz, 1001 data points, and single display is shown for the following frequencies. The three receiver architecture will simultaneously collect S

Frequency Range Sweep Speed

21

and S

11

(or S

12

and S

22

) in a single sweep

5 kHz to 6 GHz 350 μs/point typical

> 6 GHz to 20 GHz 650 μs/point typical

High-Level Noise

S

11

or S

22

, Short, Power = High, IFBW = 200 Hz, typical

Frequency Range Magnitude Phase

5 kHz to 6 GHz

> 6 GHz to 20 GHz

0.004 dB (rms)

0.010 dB (rms)

0.040 deg

0.050 deg

Noise Floor

10 Hz IFBW

Frequency Noise Floor

5 kHz to 2 MHz –85 dBm typical

> 2 MHz to 3 GHz –100 dBm typical

> 3 GHz to 6 GHz –96 dBm typical

> 6 GHz to 20 GHz –91 dBm typical

Temperature Stability

S

11

or S

Frequency Range

22

, Short, 23 ºC ± 5 ºC, typical

Magnitude

5 kHz to 10 GHz 0.018 dB/ºC

Phase

0.160 deg/ºC

> 10 GHz to 20 GHz 0.070 dB/ºC 0.800 deg/ºC

4 of 32

PN: 11410-00548 Rev. R MS202xC/MS203xC TDS

VNA Master MS202xC/MS203xC Specifications

VNA Functional Specifications

Measurement Parameters S

11

, S

21

, S

22

, S

12

, (optionally: S d1d1

, S c1c1

, S d1c1

Number of Traces Four: TR1, TR2, TR3, TR4

, S c1d1

)

Trace Format

Graph Types

Single, Dual, Tri, Quad, with Trace overlay capabilities

Log Magnitude, SWR, Phase, Real, Imaginary, Group Delay, Smith Chart,

Inverted Smith Chart (Admittance), Log Mag/2 (1-Port Cable Loss), Linear Polar, Log Polar,

Real Impedance, Imaginary Impedance

Domains Frequency Domain, Distance Domain, Time Domain with gating (Time Domain optional)

Frequency Start Frequency, Stop Frequency, Center Frequency, Span

Distance Start Distance, Stop Distance

Time Start Time, Stop Time

Frequency Sweep Type: Linear Single Sweep, Continuous

Data Points 2 to 4001 (arbitrary setting); data points can be reduced without recalibration.

Limit Lines Upper, Lower, 10-segmented Upper, 10-segmented Lower

Test Limits Pass/Fail for Upper, Pass/Fail for Lower, Limit Audible Alarm

Data Averaging Sweep-by-sweep

Smoothing 0 % to 20 %

IF Bandwidth (Hz) 10, 20, 50, 100, 200, 500, 1k, 2k, 5k, 10k, 20k, 50k, 100k

Reference Plane The reference planes of a calibration (or other normalization) can be changed by entering a line length.

Group Delay Aperture

Assumes no loss, flat magnitude, linear phase, and constant impedance.

Auto Reference Plane Extension Instead of manually entering a line length, this feature automatically adjusts phase shift from the current calibration (or other normalization) to compensate for external cables (or test fixtures). Assumes no loss, flat magnitude, linear phase, and constant impedance.

Defined as the frequency span over which the phase change is computed at a given frequency point. The aperture can be changed without recalibration. The minimum aperture is the frequency range divided by the number of points in calibration and can be increased to 20 % of the frequency range.

Group Delay Range < 180º of phase change within the aperture

Trace Memory A separate memory for each trace can be used to store measurement data for later display. The trace data can be saved and recalled.

Trace Math Complex trace math operations of subtraction, addition, multiplication, or division are provided.

Number of Markers Eight, arbitrary assignments to any trace

Marker Types Reference, Delta

Marker Readout Styles Log Mag, Cable Loss (Log Mag / 2), Log Mag and Phase, Phase, Real and Imaginary, SWR, Impedance,

Admittance, Normalized Impedance, Normalized Admittance, Polar Impedance, and Group Delay, Linear

Mag, Linear Mag and Phase

Marker Search Peak Search, Valley Search, Find Marker Value

Correction Models Full 2-Port, Full S

11

S

11

, Response S

22

Calibration Types Flex, Standard

, Full S

22

, Full S

11

, Response S

11

& S

22

, Response S

21

, Response S

& S

22

, One- Path Two-Port (S

11

,S

21

12

, Response S

21

& S

12

), One-Path Two-Port (S

, Response

22

,S

12

)

Calibration Methods

Calibration Standard Coefficients

Short-Open-Load-Through (SOLT), Offset-Short (SSLT), and Triple-Offset-Short (SSST),

Short-Open-Load-Reciprocal (SOLR), Double-Offset-Short-Load-Reciprocal (SSLR),

Triple-Offset-Short-Reciprocal (SSSR)

Coax: N-Connector, K-Connector, 7/16, TNC, SMA, and four User Defined coax types

Waveguide: WG11A, WG12, WG13, WG14, WG15, WG16, WG17, WG18, WG20, and four User Defined rectangular waveguide types

Cal Correction Toggle On/Off

Interpolation On/Off

Dispersion Compensation Waveguide correction that improves accuracy of distance-to-fault data by compensating for different wavelengths propagating at different speeds.

Impedance Conversion Support for 50 Ω and 75 Ω are provided.

Units Meters, Feet

Bias Tee Settings Internal, External, Off

Timebase Reference Internal, External

File Storage Types Measurement (.mna), Setup (.stp, with or without CAL), S2P (Real/Imag), S2P (Lin Mag/Phase),

S2P (Log Mag/Phase), Text (VNA Only), CSV (VNA Only), JPEG

Ethernet Configuration DHCP or Manual (Static) IP configuration, 10/100 Base-T, RJ45 jack

Languages English, French, German, Spanish, Chinese, Japanese, Korean, Italian, Russian, Portuguese (Português)

MS202xC/MS203xC TDS PN: 11410-00548 Rev. R

5 of 32

Specifications VNA Master MS202xC/MS203xC

Corrected System Performance and Uncertainties — High Port Power

Measurement Accuracy

1

(OSLN50A-18 or TOSLN50A-18)

Frequency Range

5 kHz to 20 MHz

> 20 MHz to 3 GHz

> 3 GHz to 6 GHz

> 6 GHz to 20 GHz

2

Directivity

(dB)

≥ 42

≥ 42

≥ 42

≥ 33

Transmission Uncertainty (S

21

, S

12

)

2

Transmission Magnitude Uncertainty (dB)

10

Source Match

(dB)

≥ 30

≥ 30

≥ 30

≥ 24

100

Load Match

(dB)

≥ 42

≥ 42

≥ 42

≥ 33

Reflection

Tracking (dB)

± 0.02

± 0.07

± 0.05

± 0.2

Transmission Phase Uncertainty (degrees)

Transmission

Tracking

(dB)

± 0.01

± 0.01

± 0.02

± 0.1

1

5 kHz - 20 MHz

20 MHz - 3 GHz

3 GHz - 6 GHz

6 GHz - 20 GHz

10

5 kHz - 20 MHz

20 MHz - 3 GHz

3 GHz - 6 GHz

6 GHz - 20 GHz

1

0.1

0.1

0.01

-80 -70 -60 -50 -40

Transmission Magnitude (dB)

-30

Reflection Uncertainty (S

11

, S

22

)

2

Return Loss Magnitude Uncertainty (dB)

10

-20 -10

5 kHz - 20 MHz

20 MHz - 3 GHz

3 GHz - 6 GHz

6 GHz - 20 GHz

0

0.01

-80 -70 -60 -50 -40

Transmission Magnitude (dB)

-30 -20 -10

100

Return Loss Phase Uncertainty (degrees)

5 kHz - 20 MHz

20 MHz - 3 GHz

3 GHz - 6 GHz

6 GHz - 20 GHz

10

0

1

1

0.1

-40 -35 -30 -25 -20

Return Loss Magnitude (dB)

-15 -10 -5 0

0.1

-40 -35 -30 -25 -20

Return Loss Magnitude (dB)

-15 -10 -5 0

1. Full 2-Port calibration, Default Power, 10 Hz IFBW, No averaging, 10 minute warm-up. OSLN50A-18 or TOSLN50A-18 calibration kit.

Load match specification applicable directly at corrected port only. De-rate by approximately 8 dB if using a 3670 series test port cable.

Reflection and Transmission Tracking are typical.

2. Specified only to 18 GHz, typical above 18 GHz.

6 of 32

PN: 11410-00548 Rev. R MS202xC/MS203xC TDS

VNA Master MS202xC/MS203xC Specifications

Corrected System Performance and Uncertainties — High Port Power

(continued)

Measurement Accuracy

1

(OSLNF50A-18, or TOSLNF50A-18)

Frequency Range

5 kHz to 20 MHz

> 20 MHz to 3 GHz

> 3 GHz to 6 GHz

> 6 GHz to 20 GHz

2

Directivity

(dB)

≥ 42

≥ 42

≥ 42

≥ 33

Transmission Uncertainty (S

21

, S

12

)

2

Transmission Magnitude Uncertainty (dB)

10

Source Match

(dB)

≥ 30

≥ 30

≥ 30

≥ 24

100

Load Match

(dB)

≥ 42

≥ 42

≥ 42

≥ 33

Reflection

Tracking (dB)

± 0.02

± 0.07

± 0.05

± 0.2

Transmission Phase Uncertainty (degrees)

Transmission

Tracking

(dB)

± 0.01

± 0.01

± 0.02

± 0.1

1

5 kHz - 20 MHz

20 MHz - 3 GHz

3 GHz - 6 GHz

6 GHz - 20 GHz

10

5 kHz - 20 MHz

20 MHz - 3 GHz

3 GHz - 6 GHz

6 GHz - 20 GHz

1

0.1

0.1

0.01

-80 -70 -60 -50 -40

Transmission Magnitude (dB)

-30

Reflection Uncertainty (S

11

, S

22

)

2

Return Loss Magnitude Uncertainty (dB)

10

-20 -10

5 kHz - 20 MHz

20 MHz - 3 GHz

3 GHz - 6 GHz

6 GHz - 20 GHz

0

0.01

-80 -70 -60

100

-50 -40

Transmission Magnitude (dB)

-30 -20

Return Loss Phase Uncertainty (degrees)

10

1

1

-10

5 kHz - 20 MHz

20 MHz - 3 GHz

3 GHz - 6 GHz

6 GHz - 20 GHz

0

0.1

-40 -35 -30 -25 -20

Return Loss Magnitude (dB)

-15 -10 -5 0

0.1

-40 -35 -30 -25 -20

Return Loss Magnitude (dB)

-15 -10 -5 0

1. Full 2-Port calibration, Default Power, 10 Hz IFBW, No averaging, 10 minute warm-up. OSLNF50A-18 or TOSLNF50A-18 calibration kit.

Load match specification applicable directly at corrected port only. De-rate by approximately 8 dB if using a 3670 series test port cable.

Reflection and Transmission Tracking are typical.

2. Specified only to 18 GHz, typical above 18 GHz.

MS202xC/MS203xC TDS PN: 11410-00548 Rev. R

7 of 32

Specifications VNA Master MS202xC/MS203xC

Corrected System Performance and Uncertainties — High Port Power

(continued)

Measurement Accuracy

1

(TOSLK50A-20 or TOSLK50A-40)

Frequency Range

5 kHz to 20 MHz

> 20 MHz to 3 GHz

> 3 GHz to 6 GHz

> 6 GHz to 20 GHz

Directivity

(dB)

≥ 42

≥ 42

≥ 42

≥ 36

Source Match

(dB)

≥ 33

≥ 33

≥ 33

≥ 26.5

Load Match

(dB)

≥ 42

≥ 42

≥ 42

≥ 36

Reflection

Tracking (dB)

± 0.02

± 0.07

± 0.05

± 0.2

Transmission Uncertainty (S

21

, S

12

)

Transmission Magnitude Uncertainty (dB)

10 100

Transmission Phase Uncertainty (degrees)

5 kHz - 20 MHz

20 MHz - 3 GHz

3 GHz - 6 GHz

6 GHz - 20 GHz

10

Transmission

Tracking

(dB)

± 0.01

± 0.01

± 0.02

± 0.1

5 kHz - 20 MHz

20 MHz - 3 GHz

3 GHz - 6 GHz

6 GHz - 20 GHz

1

1

0.1

0.1

0.01

-80 -70 -60 -50 -40

Transmission Magnitude (dB)

-30

Reflection Uncertainty (S

11

, S

22

)

Return Loss Magnitude Uncertainty (dB)

10

-20 -10

5 kHz - 20 MHz

20 MHz - 3 GHz

3 GHz - 6 GHz

6 GHz - 20 GHz

0

0.01

-80 -70 -60 -50 -40

Transmission Magnitude (dB)

-30 -20 -10

100

Return Loss Phase Uncertainty (degrees)

5 kHz - 20 MHz

20 MHz - 3 GHz

3 GHz - 6 GHz

6 GHz - 20 GHz

0

10

1

1

0.1

-40 -35 -30 -25 -20

Return Loss Magnitude (dB)

-15 -10 -5 0

0.1

-40 -35 -30 -25 -20

Return Loss Magnitude (dB)

-15 -10 -5 0

1. Full 2-Port calibration, Default Power, 10 Hz IFBW, No averaging, 10 minute warm-up. TOSLK50A-20 or TOSLK50A-40 calibration kit.

Load match specification applicable directly at corrected port only. De-rate by approximately 8 dB if using a 3670 series test port cable.

Reflection and Transmission Tracking are typical.

8 of 32

PN: 11410-00548 Rev. R MS202xC/MS203xC TDS

VNA Master MS202xC/MS203xC Specifications

Corrected System Performance and Uncertainties — High Port Power

(continued)

Measurement Accuracy

1

(TOSLKF50A-20, or TOSLKF50A-40)

Frequency Range

5 kHz to 20 MHz

> 20 MHz to 3 GHz

> 3 GHz to 6 GHz

> 6 GHz to 20 GHz

Directivity

(dB)

≥ 42

≥ 42

≥ 42

≥ 36

Source Match

(dB)

≥ 33

≥ 33

≥ 33

≥ 26.5

Load Match

(dB)

≥ 42

≥ 42

≥ 42

≥ 36

Reflection

Tracking (dB)

± 0.02

± 0.07

± 0.05

± 0.2

Transmission Uncertainty (S

21

, S

12

)

Transmission Magnitude Uncertainty (dB)

10 100

Transmission Phase Uncertainty (degrees)

5 kHz - 20 MHz

20 MHz - 3 GHz

3 GHz - 6 GHz

6 GHz - 20 GHz

10

Transmission

Tracking

(dB)

± 0.01

± 0.01

± 0.02

± 0.1

5 kHz - 20 MHz

20 MHz - 3 GHz

3 GHz - 6 GHz

6 GHz - 20 GHz

1

1

0.1

0.1

0.01

-80 -70 -60 -50 -40

Transmission Magnitude (dB)

-30

Reflection Uncertainty (S

11

, S

22

)

Return Loss Magnitude Uncertainty (dB)

10

-20 -10

5 kHz - 20 MHz

20 MHz - 3 GHz

3 GHz - 6 GHz

6 GHz - 20 GHz

0

0.01

-80 -70 -60

100

-50 -40

Transmission Magnitude (dB)

-30 -20

Return Loss Phase Uncertainty (degrees)

10

1

1

-10

5 kHz - 20 MHz

20 MHz - 3 GHz

3 GHz - 6 GHz

6 GHz - 20 GHz

0

0.1

-40 -35 -30 -25 -20

Return Loss Magnitude (dB)

-15 -10 -5 0

0.1

-40 -35 -30 -25 -20

Return Loss Magnitude (dB)

-15 -10 -5 0

1. Full 2-Port calibration, Default Power, 10 Hz IFBW, No averaging, 10 minute warm-up. TOSLKF50A-20 or TOSLKF50A-40 calibration kit.

Load match specification applicable directly at corrected port only. De-rate by approximately 8 dB if using a 3670 series test port cable.

Reflection and Transmission Tracking are typical.

MS202xC/MS203xC TDS PN: 11410-00548 Rev. R

9 of 32

Specifications VNA Master MS202xC/MS203xC

Distance Domain Specifications

(formerly Option 501, now standard with firmware revision v1.16 or higher)

Distance Domain Analysis is a powerful field test tool to analyze cables for faults, including minor discontinuities that may occur due to a loose connection, corrosion, or other aging effects. By using Frequency Domain Reflectometry (FDR), the VNA Master exploits a user-specified band of full power operational frequencies (instead of DC pulses from TDR approaches) to more precisely identify cable discontinuities. The VNA Master converts

S-parameters from frequency domain into distance domain on the horizontal display axis, using a mathematical computation called Inverse Fourier

Transform. Connect a reflection at the opposite end of the cable, and the discontinuities appear versus distance to reveal any potential maintenance issues. When access to both ends of the cable is convenient, a similar distance domain analysis is available on transmission measurements.

Distance Domain will improve your productivity with displays of the cable in terms of discontinuities versus distance. This readout can then be compared against previous measurements (from stored data) to determine whether any degradations have occurred since installation (or the last maintenance activity). More importantly, you will know precisely where to go to fix the problem and so minimize or prevent downtime of the system.

Round-Trip (reflection)

Fault Resolution (meters) (0.5 x c x Vp) / ∆F; (c is speed of light = 299,792,458 m/s, ∆F is F2 – F1 in Hz)

One-Way (transmission)

Fault Resolution (meters) (c x Vp) / ∆F; (c is speed of light = 299,792,458 m/s, ∆F is F2 – F1 in Hz)

Horizontal Range (meters) 0 to (data points – 1) x Fault Resolution to a maximum of 3000 m (9843 ft)

Windowing Rectangular, Nominal Side Lobe (NSL), Low Side Lobe (LSL), and Minimum Side Lobe (MSL)

Time Domain (Option 2) Specifications

(includes Distance Domain)

The VNA Master can display the S-parameter measurements in the time or distance domain using lowpass or bandpass processing analysis modes.

The broadband frequency coverage coupled with 4001 data points means you can measure discontinuities both near and far with unprecedented clarity for a handheld tool.

With this option, you can simultaneously view S-parameters in frequency, time, and distance domain to quickly identify faults in the field. Advanced features available with this option include step response, phasor impulse, gating, and frequency gated in time. The option includes computational routines that further enhance the Distance Domain results by compensating for cable loss, relative velocity of propagation, and dispersion compensation in waveguide. See the Distance Domain Specifications above.

Option Comparison Table (Distance Domain and Time Domain)

Measurement

Distance-to-Fault

Distance Domain display

Windowing

Distance of Waveguide

Time Domain display

One Way vs. Round Trip Reflection

Phasor Impulse

Impulse Response

Step Response

Low Pass vs. Bandpass

Frequency Gated by Time

Frequency Gated by Distance

Distance Domain

(formerly Option 501)

X

X

X

Option 2

Time Domain

X

X

X

X

X

X

X

X

X

X

X

X

Secure Data Operation (Option 7)

For highly secure data handling requirements, this software option prevents the storing of measurement setup or data information onto any internal file storage location. Instead, setup and measurement information is stored ONLY to the external USB memory location. A simple factory preset prepares the

VNA Master for transportation while the USB memory remains behind in the secure environment. The VNA Master cannot be switched between secure and non-secure operation by the user once configured for secure data operation. With this option enabled, the user can also choose to blank the frequency values displayed on the screen.

10 of 32

PN: 11410-00548 Rev. R MS202xC/MS203xC TDS

VNA Master MS202xC/MS203xC Specifications

Bias Tee (Option 10)

For tower mounted amplifier tests, the MS20x/3xC series with optional internal bias tees can supply both DC and RF signals on the center conductor of the cable during measurements. For frequency sweeps in excess of 2 MHz, the VNA Master can supply internal voltage control from +12 V to +32 V in

0.1 V steps up to 450 mA. To extend battery life, an external power supply can substitute for the internal supply by using the included external bias ports. Both test ports can be configured to supply voltage via this integrated bias tees option. Bias can be directed to VNA Port 1 or Port 2.

Bias Tee Specifications

The VNA Master offers optional integrated bias tee for supplying DC plus RF0 to the DUT as shown in the simplified block diagram. Connectivity is also provided for external supply (instead of internal) to preserve battery consumption.

Frequency Range 2 MHz to 6 GHz (MS20x6C)

2 MHz to 15 GHz (MS20x7C)

2 MHz to 20 GHz (MS20x8C)

Internal Voltage/Current +12 V to +32 V at 450 mA steady rate

Internal Resolution 0.1 V

External Voltage/Current ± 50 V at 500 mA steady rate

Bias Tee Selections Internal, External, Off

Port 1

Port 2

External Bias Input

(±50 V, 500 mA Max)

Internal

Bias Tee

Switch

Internal

Bias Tee

Internal Bias

+12 to +32 V

450 mA Max

RF Test

Source

Switch

Balanced/Differential S-Parameters, 1-Port (Option 77)

As an alternative to a sampling oscilloscope, verifying the performance and identifying discontinuities in high-data-rate differential cables is now possible with the VNA Master. After a full two-port calibration, connect your differential cable directly to the two test ports and reveal the S d1d1

performance, which is essentially differential return loss, or any of the other differential S-Parameters, S c1c1

, S d1c1 used to isolate noise and interference.

, or S c1d1

. With optional time domain, you can convert frequency sweeps to distance. This capability is especially valuable for applications in high data rate cables where balanced data formats are

Vector Voltmeter (Option 15)

A phased array system relies on phase matched cables for nominal performance. For this class of application, the VNA Master offers this special software mode to simplify phase matching cables at a single frequency. The similarity between the popular vector voltmeter and this software mode ensures minimal training is required to phase match cables. Operation is as simple as configuring the display for absolute or relative measurements. The easy-to-read large fonts show either reflection or transmission measurements using impedance, magnitude, or VSWR readouts. For instrument landing system (ILS) or VHF Omni-directional Range (VOR) applications, a table view improves operator efficiency when phase matching up to twelve cables. The

MS202x/3xC solution is superior because the signal source is included internally, precluding the need for an external signal generator.

VVM Specifications

CW Frequency Range 5 kHz to 6 GHz (MS20x6C)

5 kHz to 15 GHz (MS20x7C)

5 kHz to 20 GHz (MS20x8C)

Measurement Display CW, Table (Twelve Entries, Plus Reference)

Measurement Types Return Loss, Insertion

Measurement Format dB/VSWR/Impedance

MS202xC/MS203xC TDS PN: 11410-00548 Rev. R

11 of 32

Specifications VNA Master MS202xC/MS203xC

Spectrum Analyzer Performance Specifications (MS203xC only)

Measurements

Smart Measurements Field Strength (dBm/m

2

, dBV/m, dBmV/m, dBµV/m, V/m, Watt/m

2

, dBW/m

2

, A/m, dBA/m, or Watt/cm

2

)

Occupied Bandwidth (measures 99 % to 1 % power channel of a signal, or N dB from center of signal)

Channel Power (measures the total power in a specified bandwidth)

ACPR (adjacent channel power ratio)

Emission Mask (recall limit lines as emission mask)

Spurious Emissions (measures up to 32 segments with independent setups and limits)

C/I (carrier-to-interference ratio)

AM/FM/SSB Demodulation (AM, wide/narrow FM, upper/lower SSB), (audio only)

Setup Parameters

Frequency Center/Start/Stop, Span, Freq Step, Freq Offset, Signal Standard, Channel #, Channel Increment

Amplitude Reference Level (RL), Scale, Attenuation Auto/Level, RL Offset, Units (dBm, dBV, dBmV, dBµV, Volt, Watt, dBW, A, dBA), Pre-Amp On/Off, Detection (Peak, RMS/Avg, Negative Peak, Sample, Quasi-Peak)

Span Span, Span Up/Down (1-2-5), Full Span, Zero Span, Last Span

Bandwidth RBW, Auto RBW, VBW, Auto VBW, VBW/Avg Type (Linear, Log), RBW/VBW Ratio, Span/RBW Ratio

Impedance 50 Ω, 75 Ω; external pad required for 75 Ω operation

Sweep Functions

Sweep Single/Continuous, Sweep Time, Gated Sweep (see Option 0090)

Sweep Mode Fast (up to 100x faster than Performance), Performance, No FFT, Burst Detect (1000x Fast in 15 MHz span)

Triggers Free Run, External, Video, IF Power, Force Trigger Once

Trigger Parameters Delay, Level, Slope, Hysteresis, Holdoff (availability varies with trigger)

Trace Functions

Traces Up to three Traces (A, B, C), View/Blank, Write/Hold, Trace A/B/C Operations

Trace A Operations Normal, Max Hold, Min Hold, Average, # of Averages, (always the live trace)

Trace B Operations A → B, B ← → C, Max Hold, Min Hold

Trace C Operations A → C, B ← → C, Max Hold, Min Hold, A – B → C, B – A → C, Relative Reference (dB), Scale

Marker Functions

Markers Markers 1-6 each with a Delta Marker, or Marker 1 Reference with Six Delta Markers,

Marker Table (On/Off/Large), All Markers Off

Marker Types Style (Fixed/Tracking), Noise Marker, Frequency Counter Marker

Marker Auto-Position Peak Search, Next Peak (Right/Left), Peak Threshold %, Set Marker to Channel,

Marker Frequency to Center, Delta Marker to Span, Marker to Reference Level

Marker Table 1-6 markers frequency and amplitude, plus delta markers frequency offset and amplitude

Limit Line Functions

Available Spans > 0 Hz

Limit Lines Upper/Lower, On/Off, Edit, Move, Envelope, Advanced, Limit Alarm, Default Limit

Limit Line Edit Frequency, Amplitude, Add Point, Add Vertical, Delete Point, Next Point Left/Right

Limit Line Move To Current Center Frequency, By dB or Hz, To Marker 1, Offset from Marker 1

Limit Line Envelope Create Envelope, Update Amplitude, Number of Points (2-41), Offset, Shape Square/Slope

Limit Line Advanced Type (Absolute/Relative), Mirror, Save/Recall

Save on Event When Limit Crossed

Frequency

Frequency Range (usable to 0 Hz)

MS2036C 9 kHz to 9 GHz

MS2037C 9 kHz to 15 GHz

MS2038C 9 kHz to 20 GHz

Tuning Resolution 1 Hz

Tuning Resolution 1 Hz

Frequency Reference Aging: ± 1.0 x 10

–6

per year for 10 years

Accuracy: ± 0.3 x 10

–6

(25 °C ± 25 °C) plus aging

(see Option 31 for improved frequency reference aging and accuracy)

Auto-sensing External

Frequency Reference (MHz) 1, 1.2288, 1.544, 2.048, 2.4576, 4.8, 4.9152, 5, 9.8304, 10, 13, 19.6608

Sweep Time 7 µs to 3600 s in zero span

Sweep Time Accuracy ± 2 % in zero span

Bandwidth

Resolution Bandwidth (RBW) 1 Hz to 10 MHz in 1–3 sequence ± 10 % (–3 dB bandwidth)

Video Bandwidth (VBW) 1 Hz to 10 MHz in 1–3 sequence (–3 dB bandwidth)

RBW with Quasi-Peak Detection 200 Hz, 9 kHz, 120 kHz (–6 dB bandwidth)

VBW with Quasi-Peak Detection Auto VBW is On, RBW/VBW = 1

VBW/Average Type Linear/Log

12 of 32

PN: 11410-00548 Rev. R MS202xC/MS203xC TDS

VNA Master MS202xC/MS203xC Specifications

Spectrum Analyzer Performance Specifications (MS203xC only)

(continued)

Spectral Purity – SSB Phase Noise

Offset from 1 GHz

10 kHz

100 kHz

1 MHz

10 MHz

Maximum

–102 dBc/Hz

–106 dBc/Hz

–111 dBc/Hz

–123 dBc/Hz

Typical

–106 dBc/Hz

–110 dBc/Hz

–116 dBc/Hz

–129 dBc/Hz

Amplitude Ranges

Dynamic Range >106 dB minimum at 2.4 GHz, 2/3 (TOI-DANL) in 1 Hz RBW

Measurement Range DANL to +30 dBm

Display Range 1 to 15 dB/div in 1 dB steps, ten divisions displayed

Reference Level Range –150 dBm to +30 dBm

Attenuator Resolution 0 to 65 dB, 5.0 dB steps

Reference Level Offset 99.9 dB External Loss to 99.9 dB External Gain

Amplitude Units Log Scale Modes: dBm, dBW, dBV, dBmV, dBμV, dBA

Linear Scale Modes: fV, nV, μV, mV, V, fW, pW, nW, μW, mW, W, pA, nA, μA, mA, A

Maximum Continuous Input +30 dBm Peak typical, ± 50 VDC (≥ 10 dB Attenuation)

+23 dBm Peak typical, ± 50 VDC (< 10 dB Attenuation)

+13 dBm Peak typical, ± 50 VDC (Preamp = On)

Amplitude Accuracy

(excluding effects of VSWR, noise, and spurs)

20 °C to 30 °C

(after 30 minute warm-up)

9 kHz to 100 kHz a

> 100 kHz to 13 GHz

> 13 GHz to 18 GHz

> 18 GHz to 20 GHz

Maximum

±2.3 dB

±1.3 dB

±2.3 dB

– a. Values below 100 kHz are with the preamplifier turned off.

Typical

±0.5 dB

±0.5 dB

±0.5 dB

±1.0 dB

–10 °C to 55 °C

(after 60 minute warm-up)

Maximum

±2.3 dB

±2.3 dB

±3.3 dB

Typical

±0.5 dB

±0.5 dB

±0.5 dB

±1.0 dB

Displayed Average Noise Level (DANL)

(RMS Detection, VBW/Avg Type = Log, Ref Level = –20 dBm for Preamp Off and –50 dBm for

Preamp On, Auto Attenuation, Performance Sweep Mode)

Preamp = Off Preamp = On

10 MHz to 4 GHz

> 4 GHz to 9 GHz

> 9 GHz to 13 GHz

> 13 GHz to 20 GHz

Maximum

–145 dBm

–142 dBm

–136 dBm

–138 dBm

Typical

–148 dBm

–145 dBm

–139 dBm

–141 dBm

Maximum

–161 dBm

–159 dBm

–156 dBm

–157 dBm

Typical

–164 dBm

–162 dBm

–159 dBm

–160 dBm

Spurs

(0 dB input attenuation)

Residual Spurs (RF input terminated)

< 13 GHz

13 GHz to 20 GHz

Input-Related Spurious (–30 dBm input) a. Instrument centered on single signal, span < 1.7 GHz

Preamp = Off

Maximum

–90 dBm

–85 dBm

–60 dBc a

Third-Order Intercept (TOI)

(–20 dBm tones 100 kHz apart, 0 dB Attenuation Preamp OFF)

2.4 GHz +14 dBm minimum

50 MHz to 20 GHz +20 dBm typical

P1dB

< 4 GHz +5 dBm nominal

4 GHz to 20 GHz +12 dBm nominal

Second Harmonic Distortion

(0 dB input attenuation, –30 dBm input)

50 MHz –54 dBc maximum

< 4 GHz –60 dBc typical

≥ 4 GHz –75 dBc typical

VSWR

(≥ 10 dB input attenuation)

≤ 20 GHz 1.5:1 typical

Preamp = On

Maximum

–100 dBm

–100 dBm

–70 dBc typical

MS202xC/MS203xC TDS PN: 11410-00548 Rev. R

13 of 32

Specifications VNA Master MS202xC/MS203xC

High Accuracy Power Meter (Option 19)

(requires external USB power sensor)

Amplitude Maximum, Minimum, Offset, Relative On/Off, Units, Auto Scale

Average # of Running Averages, Max Hold

Zero/Cal Zero On/Off, Cal Factor (Center Frequency, Signal Standard)

Limits Limit On/Off, Limit Upper/Lower

Power Sensor Model

Description

Frequency Range

Connector

PSN50

High Accuracy

RF Power Sensor

50 MHz to 6 GHz

Type N(m), 50 Ω

MA24105A

Inline High

Power Sensor

350 MHz to 4 GHz

Type N(f), 50 Ω

MA24106A

High Accuracy

RF Power Sensor

50 MHz to 6 GHz

Type N(m), 50 Ω

MA24108A/18A/26A

Microwave USB

Power Sensor

10 MHz to 8/18/26 GHz

Type N(m), 50 Ω

(8/18 GHz)

Type K(m), 50 Ω

(26 GHz)

–40 dBm to +20 dBm

(0.1 µW to 100 mW)

Dynamic Range

Measurand

Measurement Uncertainty

Data sheet

(for complete specifications)

Notes:

–30 dBm to +20 dBm

(0.001 mW to

100 mW)

True-RMS

± 0.16 dB

1

11410-00414

+3 dBm to +51.76 dBm

(2 mW to 150 W)

True-RMS

± 0.17 dB

2

11410-00621

–40 dBm to +23 dBm

(0.1 µW to 200 mW)

True-RMS

± 0.16 dB

1

11410-00424

True-RMS

± 0.18 dB

3

11410-00504

1. Total RSS measurement uncertainty (0 ºC to 50 ºC) for power measurements of a CW signal greater than –20 dBm with zero mismatch errors.

2. Expanded uncertainty with K=2 for power measurements of a CW signal greater than +20 dBm with a matched load.

Measurement results referenced to the input side of the sensor.

3. Expanded uncertainty with K=2 for power measurements of a CW signal greater than –20 dBm with zero mismatch errors.

Interference Analyzer (Option 25)

Measurements

Spectrum Field Strength

Occupied Bandwidth

Channel Power

Adjacent Channel Power (ACPR)

AM/FM/SSB Demodulation (Wide/Narrow FM, Upper/Lower SSB), (audio out only)

Carrier-to-Interference ratio (C/I)

Spectrogram Collect data up to 3 days

Signal Strength Gives visual and aural indication of signal strength

Received Signal Strength Indicator (RSSI) Collect data up to one week

Interference Mapping Draw multiple bearings of signal strength from GPS location on on-screen map

Pan and Zoom on-screen maps

Support for Anritsu MA2700A Handheld Interference Hunter

Impedance 50 Ω, 75 Ω; external pad required for 75 Ω operation

Channel Scanner (Option 27)

General

Number of Channels 1 to 20 Channels (Power Levels)

Measurements Graph/Table, Max Hold (On/5 s/Off), Frequency/Channel, Current/Maximum, Dual Color

Scanner Scan Channels, Scan Frequencies, Scan Custom List, Scan Script Master™

Amplitude Reference Level, Scale

Custom Scan Number of Channels, Signal Standard & Channel, Frequency, Bandwidth

Frequency Range 9 kHz to 9, 15, or 20 GHz

Frequency Accuracy ± 10 Hz + frequency reference error

Measurement Range –110 dBm to +30 dBm

Impedance 50 Ω, 75 Ω; external pad required for 75 Ω operation

14 of 32

PN: 11410-00548 Rev. R MS202xC/MS203xC TDS

VNA Master MS202xC/MS203xC Specifications

Coverage Mapping (Option 431)

Measurements

Indoor Mapping RSSI, ACPR

Outdoor Mapping RSSI, ACPR

Setup Parameters

Mode Spectrum Analyzer

Frequency Center, Span (ACPR only), Freq Step, Signal Standard, Channel #, Channel Increment

Amplitude Reference Level (RL), Attenuation Auto/Level, RL Offset, Pre-Amp On/Off, Detection

Span RSSI Mode: Zero Span

ACPR Mode: Span, Span Up/Down (1-2-5), Full Span, Last Span

BW RBW, Auto RBW, VBW, Auto VBW, RBW/VBW Ratio, Span/RBW Ratio

Measurement Setup RSSI: Mapping color thresholds

ACPR: Main Ch BW, Adj Ch BW, Ch Spacing, Adjacent Ch dB Offset, Thresholds for Good and Poor main channel levels

Mapping Colors RSSI: Dark Green (Excellent), Light Green (Very Good), Yellow (Good), Orange (Fair), Dark Red (Poor)

ACPR: Dark Green (Good), Yellow (between Good and Poor), Dark Red (Poor)

Point Distance or Time Setup Repeat Type: Time (100 ms to 16 s), Distance (1 m to 10,000 m)

Distance Units: m, ft

Save Points Map Save KML, JPEG, Tab Delimited

Recall Points Map Recall Map, Recall KML Points only, Recall KML Points with Map, Recall Default Grid

Map Types Outdoor (GPS embedded), Indoor (non-GPS embedded). Import maps using the Anritsu easyMap Tools.

Zoomable (.azm) maps are usable, but cannot be zoomed.

GPS Receiver (Option 31)

Setup On/Off, Antenna Voltage 3.3 V/5.0 V, GPS Info

Note: Anritsu 2000-1528-R GPS antenna requires +5 VDC

Anritsu 2000-1652-R GPS antenna requires +3.3 VDC or +5 VDC

Anritsu 2000-1760-R GPS antenna requires +2.5 VDC to +3.7 VDC

GPS Time/Location Indicator UTC Time, Latitude, Longitude, and Altitude on display (UTC Time and Altitude on GPS Info display)

UTC Time, Latitude, Longitude, and Altitude with trace storage

High Frequency Accuracy < ± 2.5 x 10

–8

Hz/Hz with GPS On, 3 minutes after satellite lock in selected mode (GPS Antenna connected)

< ± 5.0 x 10

–8

Hz/Hz for 3 days after GPS lock, 0 °C to 50 °C (GPS Antenna disconnected)

Connector SMA, female

MS202xC/MS203xC TDS PN: 11410-00548 Rev. R

15 of 32

Specifications

AM/FM/PM Signal Analyzer (Option 509, MS203xC only)

VNA Master MS202xC/MS203xC

Measurements

Display

Type

RF Spectrum

(AM/FM/PM)

Graphic

Display

Power (dBm) vs.

Frequency

Numerical

Displays

Carrier Power

Carrier Frequency

Occupied BW

Audio Spectrum

(AM)

Depth (%) vs.

Modulation Frequency

Audio Spectrum

(FM/PM)

Deviation (kHz/rad) vs.

Modulation Frequency

AM Rate

RMS Depth

(Pk-Pk)/2 Depth

SINAD*

THD*

Distortion/Total Vrms*

FM/PM Rate

RMS Deviation

(Pk-Pk)/2 Deviation

SINAD*

THD*

Distortion/Total Vrms*

Audio

Waveform (AM)

Depth (%) vs.

Time

Audio Waveform

(FM/PM)

Deviation (kHz/rad) vs.

Time

Summary

(AM)

Summary

(FM/PM)

None None

AM Rate

RMS Depth

(Pk-Pk)/2 Depth

SINAD*

THD*

Distortion/Total Vrms*

FM/PM Rate

RMS Deviation

(Pk-Pk)/2 Deviation

SINAD*

THD*

Distortion/Total Vrms*

RMS Depth

Peak + Depth

Peak – Depth

(Pk-Pk)/2 Depth

Carrier Power

Carrier Frequency

Occupied Bandwidth

AM Rate

SINAD*

THD*

Distortion/Total Vrms*

RMS Deviation

Peak + Deviation

Peak – Deviation

(Pk-Pk)/2 Deviation

Carrier Power

Carrier Frequency

Occupied Bandwidth

FM/PM Rate

SINAD*

THD*

Distortion/Total Vrms*

* Requires sine wave modulation

Setup Parameters

Frequency Center Freq, Span, Freq Step, Signal Standard, Channel, Channel Increment, Set (measured) Carrier Freq to Center

Amplitude Setup Scale, Power Offset, Adjust Range

Measurements RF Spectrum, Audio Spectrum (demodulated), Audio Waveform (demodulated), Summary, Coverage

Mapping (Option 431 required), Audio Demod (AM/FM only)

Measurement Setup All Measurements: Demod Type (AM, FM, PM), IFBW, Auto IFBW, Squelch Units, Distortion Measurements

(Sinewave or Broadcast)

RF Spectrum: OBW Method, OBW %, OBW dBC

Audio Spectrum: Span, Scale, Squelch Power

Audio Waveform: Sweep Time, Scale, Squelch Power

Summary: Average count, Squelch Power

Coverage Mapping: Measurement (SINAD, Carrier Power, Multiple), Thresholds, Point Distance/Time

Audio Demod: Demod Type (AM, USB, LSB, Widband FM, Narrowband FM), Volume, Squelch

Mapping Colors Dark Green (Excellent), Light Green (Very Good), Orange (Good), Yellow (Fair), Dark Red (Poor)

Marker Six markers with Delta for each, Peak Search, Marker Freq to Center, Marker to Ref Lvl, Marker Table

RF and Modulation Measurements

AM Modulation Rate: ± 1 Hz (< 100 Hz), ± 2 % (> 100 Hz)

Depth: ± 5 % for (Modulation rates 10 Hz to 100 kHz)

FM Modulation Rate: ± 1 Hz (< 100 Hz); ± 2 % (100 Hz to 100 kHz)

Deviation Accuracy: ± 5 % (100 Hz to 100 kHz)**

PM Modulation Rate: ± 1 Hz (< 100 Hz); ± 2 % (100 Hz to 100 kHz)

Deviation Accuracy: ± 5 % (deviation 0 to 93 Rad, rate 10 Hz to 5 kHz)**

IF Bandwidth 1 kHz to 300 kHz in 1-3 sequence

Frequency Span RF Spectrum: 10 kHz to 10 MHz

Audio Spectrum: 2 kHz, 5 kHz, 10 kHz, 20 kHz, 70 kHz, 140 kHz

RBW/VBW 30

Span/RBW 100

Sweep Time 50 µs to 50 ms (Audio Waveform)

** IFBW must be greater than 95 % occupied BW

16 of 32

PN: 11410-00548 Rev. R MS202xC/MS203xC TDS

VNA Master MS202xC/MS203xC Specifications

General Specifications

Setup Parameters

System Status (Temperature, Battery Info, Serial Number, Firmware Version, IP Address, Options Installed)

Self Test, Application Self Test, GPS (see Option 31)

System Options Name, Date and Time, Ethernet Configuration, Brightness, Volume,

Language (English, French, German, Spanish, Chinese, Japanese, Korean, Italian, Russian, Portuguese),

Reset (Factory Defaults, Master Reset, Update Firmware)

File Save, Recall, Delete, Directory Management

Save/Recall Setups, Measurements, Screen Shots JPEG (save only)

Delete Selected File, All Measurements, All Mode Files, All Content

Directory Management Sort Method (Name/Type/Date), Ascend/Descend, Internal/USB, Copy

Internal Trace/Setup Memory Store more than 4000 traces and setups in memory

External Trace/Setup Memory Limited by size of USB Flash drive

Mode Switching Auto-Stores/Recalls most recently used Setup Parameters in the Mode

Connectors

Maximum Input (Damage Level) Vector Network Analyzer Input: +23 dBm, ± 50 VDC (all models)

Spectrum Analyzer Input: +30 dBm, ± 50 VDC (MS203xC models only)

VNA Connectors Type N, female (or ruggedized K female with Option 11, MS20x7C or MS20x8C only) (x2)

Spectrum Analyzer Connectors Type N, female (or ruggedized K female with Option 11, MS2037C or MS2038C only)

Bias Tee Type BNC female (enabled with Option 10) (x2)

Ext Ref Type BNC, female, 10 MHz, ± 10 dBm

GPS SMA female (available with Option 31 GPS)

External Power 5.5 mm barrel connector, 12 VDC to 14.5 VDC, < 5.0 A

LAN Connection RJ48C, 10/100 Mbps, Connect to PC or LAN for Remote Access

USB Interface (2) Type A, Connect Flash Drive and Power Sensor

USB Interface 5-pin mini-B, Connect to PC for data transfer

Headset Jack 3.5 mm 3-wire headset jack

External Trigger BNC, female, TTL 3.3 V or 5 V triggers on positive edge, Maximum Input + 5 VDC

10 MHz Out SMA, female, 50 Ω

Display

Size 8.4 in, daylight viewable color LCD

Resolution 800 x 600

Power

Field replaceable Li-Ion Battery 40 W when powered by factory 7500 mAh Li-Ion battery (part number: 633-75)

AC/DC Power Adapter 55 W when powered by supplied universal 110/220 V AC/DC adaptor while charging battery

Life-time Charging Cycles > 300 (80 % of initial capacity)

Battery Operation

Battery Charging Limits

3.0 hours typical

0 °C to +45 °C, Relative Humidity ≤ 80 %, non-condensing

Size and Weight

Dimensions Height: 211 mm (8.3 in)

Width: 315 mm (12.4 in)

Depth: 78 mm (3.1 in) (MS202xC), 97 mm (3.8 in) (MS203xC)

Weight, Including Battery 4.5 kg (9.9 lb) (MS202xC), 4.8 kg (10.5 lb) (MS203xC)

Warranty

Duration Standard three-year warranty (one year warranty on battery)

MS202xC/MS203xC TDS PN: 11410-00548 Rev. R

17 of 32

Specifications VNA Master MS202xC/MS203xC

General Specifications

(continued)

Safety

Safety Class EN 61010-1 Class 1

Product Safety IEC 60950-1 when used with Anritsu-supplied Power Supply

Electromagnetic Compatibility

European Union CE Mark, EMC Directive 89/336/EEC, 92/31/EEC, 93/68/EEC and

Low Voltage Directive 73/23/EEC, 93/68/EEC

Interference EN 61326-1

Emissions EN 55011

Immunity EN 61000-4-2/-4-3/-4-4/-4-5/-4-6/-4-11

Australia and New Zealand C-tick N274

Environmental

MIL-PRF-28800F, Class 2

Temperature, operating (ºC)

(3.8.2.1 & 4.5.5.14) Passed, –10 ºC to 55 ºC, relative humidity 85 % non-condensing

Temperature, not operating (ºC)

(3.8.2.2 & 4.5.5.1) Passed, –51 ºC to 71 ºC

Relative humidity (3.8.2.3 & 4.5.5.1) Passed

Altitude, not operating (3.8.3 & 4.5.5.2) Passed, 4600 m (Qualified by similarity — tested on a similar product)

Altitude, operating (3.8.3 & 4.5.5.2) Passed, 4600 m (Qualified by similarity — tested on a similar product)

Vibration limits (3.8.4.1 & 4.5.5.3.1) Passed

Shock, functional (3.8.5.1 & 4.5.5.4.1) Passed

Transit Drop (3.8.5.2 & 4.5.5.4.2) Passed

Bench handling (3.8.5.3 & 4.5.5.4.3) Passed

Shock, high impact (3.8.5.4 & 4.5.5.4.4) Not Required (Not defined in standard; must be invoked and defined by purchase description)

Salt exposure structural parts

(3.8.8.2 & 4.5.6.2.2) Not required for Class 2 equipment

Explosive Atmosphere

MIL-PRF-28800F, Section 4.5.6.3

Passed

MIL-STD-810G,

Method 511.5, Procedure 1 Passed

18 of 32

PN: 11410-00548 Rev. R MS202xC/MS203xC TDS

VNA Master MS202xC/MS203xC Specifications

Line Sweep Tools™

(for your PC)

Trace Capture

Browse to Instrument

Open Legacy Files

View and copy traces from the test equipment to your PC using Windows Explorer

Open DAT files captured with Handheld Software Tools v6.61

Open Current Files Open VNA or DAT files

Capture Plots To The Line Sweep Tools screen, DAT files, Database, or JPEG

Traces

Trace Types

Trace Formats

Return Loss, VSWR, DTF-RL, DTF-VSWR, Cable Loss, Smith Chart, and PIM

DAT, VNA, CSV, PNG, BMP, JPG, HTML, Data Base, and PDF

Report Generation

Report Generator Includes GPS location along with measurements

Report Format Create reports in HTML or PDF format

Report Setup Report Title, Company, Prepared for, Location, Date and Time, Filename, Company logo

Trace Setup 1 Trace Portrait Mode, 2 Trace Portrait Mode, 1 Trace Landscape Mode

Trace Validation

Presets 7 presets allow “one click” setting of up to 6 markers and one limit line

Marker Controls 6 regular Markers, Marker Peak, Marker Valley, Marker between, and frequency entry

Delta Markers 6 Delta markers

Limit Line Enable and drag or value entry. Also works with presets

Next Trace Button Next Trace and Previous Trace arrow keys allow quick switching between traces

Tools

Cable Editor Allows creation of custom cable parameters

Distance to Fault Converts a Return Loss trace to a Distance to Fault trace

Measurement Calculator Converts Real, Imaginary, Magnitude, Phase, RL, VSWR, Rho, and Transmit power

Signal Standard Editor Creates new band and channel tables

Renaming Grid 36 user-definable phrases for creation of file names, trace titles, and trace subtitles

Connectivity

Connections Connect to PC using Serial, USB, or Ethernet

Download Download measurements and live traces to PC for storage and analysis

Upload Upload measurements from PC to instrument

Master Software Tools

(for your PC)

Measurement Viewing

Display Modify display settings, including scale

Spectrum Traces Add, delete, and modify limit lines and markers. Overlay traces.

Spectrum Analyzer Measurements Field Strength, Occupied Bandwidth, Channel Power, ACPR, Emission Mask, C/I

1

Interference Analyzer Measurements Spectrograms, Signal Strength Meter, RSSI

2

Non-Spectrum Measurements Hi Accuracy Power Meter, Channel Scanner, GSM, WCDMA/HSPA, LTE, TD-LTE, TD-SCDMA, CDMA, EV-DO,

Fixed WiMAX, Mobile WiMAX, Screen captures (JPEGs)

1. Spurious Emissions results viewable in a browser

2. Coverage and Interference Mapping files are viewable in a spreadsheet, Google Earth, or Google Maps.

Database Management

Full Trace Retrieval Retrieve all traces from instrument into one PC directory (limited to approximately 15,000 files)

Trace Catalog Index all traces in selected folder & subfolder on PC into one catalog

Trace Rename Utility Rename measurement traces

Group Edit Titles, subtitles, plot scaling, markers and limit lines, simultaneously on similar files

Data Analysis

Trace Math and Smoothing Compare multiple traces

Measurement Calculator Translate into other units

Report Generation

Report Generator Includes GPS, power level, and measurements

Edit Graph Change scale, limit lines, and markers

Report Format Create reports in HTML

Export Measurements Export measurements or entire folders to *.jpg or *.csv format

Notes Annotate measurements

Mapping

(GPS required on instrument)

Spectrum Analyzer Mode MapInfo

LTE Mode Google Earth, Google Maps

MS202xC/MS203xC TDS PN: 11410-00548 Rev. R

19 of 32

Specifications VNA Master MS202xC/MS203xC

Master Software Tools

(continued)

Spectrogram

(Spectrum Monitoring for Interference Analysis and Spectrum Clearing)

Source Recorded Spectrogram or multiple spectrum traces

Folder Spectrogram 2D View creates a composite file of multiple traces

Available Displays Spectrogram, Peak Power vs. Time, Variation in Total Power vs. Time, Peak Frequency vs. Time, Number of

Traces Saved vs. Time (useful with Save on Limit Exceeded), Maximum/Average/Minimum Power vs. Time

File Filter (Violations over limit lines or deviations from averages)

Playback

Display Functions per Trace Markers, GPS location altitude and time (when recorded), instrument time

Filename per trace for Folder Spectrogram

Export to Video Create AVI file of 2D Spectrogram for management review/reports

Export to 3D Spectrogram Views (Set Threshold, Markers)

- 3D (Rotate X, Y, Z Axis, Level Scale, Signal ID)

- 2D (Frequency or Time Domain, Signal ID)

- Top Down

Playback (Frequency and/or Time Domain)

List/Parameter Editors

Antennas, Cables, Signal Standards Modify instrument’s Antenna, Cable, and Signal Standard List

Pass/Fail Create, download, or edit Signal Analysis Pass/Fail Limits

Script Master Create Script Master files for GSM/WCDMA or Channel Scanner

Languages Modify non-English language menus

Mobile WiMAX DL-MAP Parameters

Connectivity

Connections Connect to PC using USB, LAN, or Direct Ethernet connection

Network Search Find all Anritsu handheld instruments on local network

Download Download measurements and live traces to PC for storage and analysis

Upload Upload measurements and other files from PC to instrument

Remote Access Tool Remote control and monitoring of instrument (via Ethernet port) over the Internet

Export Measurements can be saved in various formats, depending on the measurement type, including JPEG, CSV, and Anritsu DAT format

Printing Print individual or all measurement screens

20 of 32

PN: 11410-00548 Rev. R MS202xC/MS203xC TDS

VNA Master MS202xC/MS203xC Ordering Information

Ordering Information

VNA Master™ Handheld Vector Network Analyzer + Spectrum Analyzer

Includes standard three-year warranty and Certificate of Calibration and Conformance.

MS2026C MS2027C MS2028C MS2036C MS2037C MS2038C

5 kHz to 6 GHz 5 kHz to 15 GHz 5 kHz to 20 GHz 5 kHz to 6 GHz

9 kHz to 9 GHz

5 kHz to 15 GHz

9 kHz to 15 GHz

5 kHz to 20 GHz

9 kHz to 20 GHz

Description

Vector Network Analyzer

Spectrum Analyzer

MS2026C-0002 MS2027C-0002 MS2028C-0002 MS2036C-0002 MS2037C-0002 MS2038C-0002 Time Domain (includes

Distance Domain capabilities)

MS2026C-0007 MS2027C-0007 MS2028C-0007 MS2036C-0007 MS2037C-0007 MS2038C-0007 Secure Data Operation

MS2026C-0010 MS2027C-0010 MS2028C-0010 MS2036C-0010 MS2037C-0010 MS2038C-0010 Built-in Bias-Tee

MS2027C-0011 MS2028C-0011 MS2037C-0011 MS2038C-0011 K(f) Test Port Connectors

(MS20x7C & MS20x8C only)

MS2026C-0015 MS2027C-0015 MS2028C-0015 MS2036C-0015 MS2037C-0015 MS2038C-0015 Vector Voltmeter

MS2026C-0019 MS2027C-0019 MS2028C-0019 MS2036C-0019 MS2037C-0019 MS2038C-0019 High Accuracy Power Meter

(requires external USB sensor)

MS2036C-0025 MS2037C-0025 MS2038C-0025 Interference Analysis, a

9 kHz to 9/15/20 GHz

MS2036C-0027 MS2037C-0027 MS2038C-0027 Channel Scanner, a

9 kHz to 9/15/20 GHz

MS2026C-0031 MS2027C-0031 MS2028C-0031 MS2036C-0031 MS2037C-0031 MS2038C-0031 GPS Receiver (requires GPS antenna,

2000-1528-R, 2000-1652-R, or

2000-1760-R)

MS2026C-0077 MS2027C-0077 MS2028C-0077 MS2036C-0077 MS2037C-0077 MS2038C-0077 Balanced/Differential S-Parameters,

1-Port

MS2036C-0431 MS2037C-0431 MS2038C-0431 Coverage Mapping b

MS2026C-0098 MS2027C-0098 MS2028C-0098 MS2036C-0098 MS2037C-0098 MS2038C-0098 Standard Calibration

(ISO 17025 and Z540.1)

MS2026C-0099 MS2027C-0099 MS2028C-0099 MS2036C-0099 MS2037C-0099 MS2038C-0099 Premium Calibration

(ISO 17025 and Z540.1 plus test data)

MS2036C-0509 MS2037C-0509 MS2038C-0509 AM/FM/PM Analyzer c a. Option 31 (GPS) is recommended.

b. Requires Option 31 (GPS) for full functionality.

c. Requires Option 431 (Coverage Mapping) for full functionality.

Standard Accessories

(included with instrument)

Part Number Description

10920-00060 Anritsu Handheld Instruments Documentation Disc

2000-1685-R Soft Carrying Case (supplied with MS202xC only)

2000-1686-R Soft Carrying Case (supplied with MS203xC only)

2300-577 Anritsu Software Tool Box for Handheld RF Instruments Disc

633-75 Rechargeable Li-Ion Battery

40-187-R AC-DC Adapter

806-141-R Automotive Power Adapter, 12 VDC, 60 W

633-75 Rechargeable Li-Ion Battery

3-2000-1498 USB A/5-pin Mini-B Cable, 3.05 m (10 ft)

2000-1371-R Ethernet Cable, 2.13 m (7 ft)

Certificate of Calibration and Conformance

MS202xC/MS203xC TDS PN: 11410-00548 Rev. R

21 of 32

Ordering Information

Optional Accessories

Miscellaneous Accessories

Backpack and Transit Case

VNA Master MS202xC/MS203xC

MA2700A Handheld Interference Hunter (For full specifications, refer to the

MA2700A Technical Data Sheet 11410-00692)

2000-1371-R Ethernet Cable, 2.1 m (7 ft)

3-806-152 Cat 5e Crossover Patch Cable, 2.1 m (7 ft)

633-75 Rechargeable Li-Ion Battery, 7500 mAh

66864 Rack Mount Kit

2000-1689 EMI Near Field Probe Kit

2300-517 Phase Noise Measurement Software

67135 Anritsu Backpack (For Handheld Instrument and PC)

760-243-R Large Transit Case with Wheels and Handle

760-261-R Transit Case, space for MA2700A, antennas, filters, instrument inside softcase, and other interference hunting accessories/tools

760-271-R Transit Case for Portable Directional Antennas and Port Extender

(2000-1777-R, 2000-1778-R, 2000-1779-R, 2000-1798-R)

GPS Antennas

(active)

2000-1652-R Magnet Mount, SMA(m), 3 VDC to 5 VDC with 1 ft cable

2000-1528-R Magnet Mount, SMA(m), 3 VDC to 5 VDC with 4.6 m (15 ft) extension cable

2000-1760-R Mini GPS Antenna, SMA(m), 25 dB gain, 2.5 VDC to 3.7 VDC

Power Sensors

(For complete ordering information see the respective datasheets of each sensor)

PSN50 High Accuracy RF Power Sensor, 50 MHz to 6 GHz, +20 dBm

MA24105A Inline Power Sensor, 350 MHz to 4 GHz, +3 dBm to +51.76 dBm

MA24106A High Accuracy RF Power Sensor, 50 MHz to 6 GHz, +23 dBm

MA24108A Microwave USB Power Sensor, 10 MHz to 8 GHz, +20 dBm

MA24118A Microwave USB Power Sensor, 10 MHz to 18 GHz, +20 dBm

MA24126A Microwave USB Power Sensor, 10 MHz to 26 GHz, +20 dBm

MA25100A RF Power Indicator

22 of 32

PN: 11410-00548 Rev. R MS202xC/MS203xC TDS

VNA Master MS202xC/MS203xC Ordering Information

Optional Accessories

(continued)

Full Temperature Coaxial Calibration Kits

(–10 °C to +55 °C , K Type is compatible with 3.5 mm and SMA connectors see individual data sheets on www.anritsu.com)

OSLN50A-8 High Performance Type N(m), DC to 8 GHz, 50 Ω

OSLNF50A-8 High Performance Type N(f), DC to 8 GHz, 50 Ω

TOSLN50A-8 High Performance with Through Type N(m), DC to 8 GHz, 50 Ω

TOSLNF50A-8 High Performance with Through Type N(f), DC to 8 GHz, 50 Ω

OSLN50A-18 High Performance Type N(m), DC to 18 GHz, 50 Ω

OSLNF50A-18 High Performance Type N(f), DC to 18 GHz, 50 Ω

TOSLN50A-18 High Performance with Through Type N(m), DC to 18 GHz, 50 Ω

TOSLNF50A-18 High Performance with Through Type N(f), DC to 18 GHz, 50 Ω

TOSLK50A-20 High Performance with Through Type K(m), DC to 20 GHz, 50 Ω

TOSLKF50A-20 High Performance with Through Type K(f), DC to 20 GHz, 50 Ω

TOSLK50A-40 High Performance with Through Type K(m), DC to 40 GHz, 50 Ω

TOSLKF50A-40 High Performance with Through Type K(f), DC to 40 GHz, 50 Ω

Coaxial Calibration Components, N Type 50 Ω, K Type 50 Ω

(K Type is compatible with 3.5 mm and SMA connectors)

22N50 Precision Open/Short, N(m), DC to 18 GHz, 50 Ω

22NF50 Precision Open/Short, N(f), DC to 18 GHz, 50 Ω

28N50-2 Precision Load, N(m), DC to 18 GHz, 50 Ω

28NF50-2 Precision Load, N(f), DC to 18 GHz, 50 Ω

22K50 Precision Open/Short, K(m), DC to 40 GHz, 50 Ω

22KF50 Precision Open/Short, K(f), DC to 40 GHz, 50 Ω

28K50 Precision Load, K(m), DC to 40 GHz, 50 Ω

28KF50 Precision Load, K(f), DC to 40 GHz, 50 Ω

Coaxial Calibration Components, Other 50 Ω, 75 Ω

2000-1618-R Open/Short/Load, 7/16 DIN(m), DC to 6.0 GHz 50 Ω

2000-1619-R Open/Short/Load, 7/16 DIN(f), DC to 6.0 GHz 50 Ω

12N50-75B Matching Pad, DC to 3 GHz, 50 Ω to 75 Ω

22N75 Open/Short, N(m), DC to 3 GHz, 75 Ω

22NF75 Open/Short, N(f), DC to 3 GHz, 75 Ω

26N75A Precision Termination, N(m), DC to 3 GHz, 75 Ω

26NF75A Precision Termination, N(f), DC to 3 GHz, 75 Ω

SM/PL-1 Precision N(m) Load, 42 dB, 6 GHz

SM/PLNF-1 Precision N(f) Load, 42 dB, 6 GHz

1091-55-R Open, TNC(f), DC to 18 GHz

1091-53-R Open, TNC(m), DC to 18 GHz

1091-56-R Short, TNC(f), DC to 18 GHz

1091-54-R Short, TNC(m), DC to 18 GHz

1015-54-R Termination, TNC(f), DC to 18 GHz

1015-55-R Termination, TNC(m), DC to 18 GHz

MS202xC/MS203xC TDS PN: 11410-00548 Rev. R

23 of 32

Ordering Information VNA Master MS202xC/MS203xC

Optional Accessories

(continued)

Waveguide Calibration Components and WG/Coaxial Adapters, Rectangular Type 50 Ω

Recommended waveguide calibration procedure requires two offset shorts and a precision load. The waveguide/coax adapter, shown attached to test port #1, adapts the VNA Master test ports to the waveguide under test.

Frequency Range

(GHz)

3.30 to 4.90

3.95 to 5.85

5.85 to 8.20

7.05 to 10.00

8.20 to 12.40

10.00 to 15.00

12.40 to 18.00

17.00 to 26.50

26.50 to 40.00

3.30 to 4.90

3.95 to 5.85

5.85 to 8.20

7.05 to 10.00

8.20 to 12.40

10.00 to 15.00

12.40 to 18.00

17.00 to 26.50

1/8 Offset

23UA229

23UA187

23UA137

23UA112

23UA90

23UA75

23UA62

23UA42

23UA28

23UM40

23UM48

23UM70

23UM84

23UM100

23UM120

23UM140

23UM220

3/8 Offset

24UA229

24UA187

24UA137

24UA112

24UA90

24UA75

24UA62

24UA42

24UA28

24UM40

24UM48

24UM70

24UM84

24UM100

24UM120

24UM140

24UM220

Termination

26UA229

26UA187

26UA137

26UA112

26UA90

26UA75

26UA62

26UA42

26UA28

26UM40

26UM48

26UM70

26UM84

26UM100

26UM120

26UM140

26UM220

Coax to Waveguide

Adapter

35UA229N

35UA187N

Compatible Flanges

PDR40

CPR187F, CPR187G, UG-1352/U, UG-1353/U,

UG-1728/U, UG-1729/U, UG-148/U, UG-149A/U

35UA137N

35UA112N

35UA90N

35UA75N

35UA62N

35UA42K

35UA28K

35UM40N

35UM48N

35UM70N

35UM84N

35UM100N

35UM120N

35UM140N

35UM220K

CPR137F, CPR137G, UG-1356/U, UG-1357/U,

UG-1732/U, UG-1733/U, UG-343B/U, UG-344/U,

UG-440B/U, UG-441/U

CPR112F, CPR112G, UG-1358/U, UG-1359/U,

UG-1734/U, UG-1735/U, UG-52B/U, UG-51/U,

UG-137B/U, UG-138/U

CPR90F, CPR90G, UG-1360/U, UG-1361/U, UG-1736/U,

UG-1737/U, UG-40B/U, UG-39/U, UG-135/U, UG-136B/U

UBR120

UG-541A/U, UG-419/U, UG-1665/U, UG1666/U

UG-596A/U, UG-595/U, UG-597/U, UG-598A/U

UG-599/U

PDR40

CAR48, PAR48, UAR48, PDR48

CAR70, PAR70, UAR 70, PDR70

CBR84, UBR84, PBR84, PDR84

CBR100, UBR100, PBR100, PDR100

CBR120, UBR120, PBR120, PDR120

CBR140, UBR140, PBR140, PDR140

CBR220, UBR220, PBR220, PDR220

* For Coaxial/Waveguide Adapter part numbers, N designates Type N and K designates K-Connector

24 of 32

PN: 11410-00548 Rev. R MS202xC/MS203xC TDS

VNA Master MS202xC/MS203xC Ordering Information

Optional Accessories

(continued)

Phase-Stable Test Port Extension Cables (Armored and Flexible)

Part Number Description

14KFKF50-0.6 0.6 m (24 in), DC to 40 GHz, K(f) to K(f), 50 Ω

14KFKF50-1.0 1.0 m (39 in), DC to 40 GHz, K(f) to K(f), 50 Ω

14KFK50-0.6 0.6 m (24 in), DC to 40 GHz, K(f) to K(m), 50 Ω

14KFK50-1.0 1.0 m (39 in), DC to 40 GHz, K(f) to K(m), 50 Ω

15NN50-1.0B 1.0 m (39 in), DC to 18 GHz, N(m) to N(m), 50 Ω

15NNF50-1.0B 1.0 m (39 in), DC to 18 GHz, N(m) to N(f), 50 Ω

15LL50-1.0A 1.0 m (39 in), DC to 20 GHz, 3.5 mm(m) to 3.5 mm(m), 50 Ω

15LLF50-1.0A 1.0 m (39 in), DC to 20 GHz, 3.5 mm(m) to 3.5 mm(f), 50 Ω

15KK50-1.0A 1.0 m (39 in), DC to 26.5 GHz, K(m) to K(m), 50 Ω

15KKF50-1.0A 1.0 m (39 in), DC to 26.5 GHz, K(m) to K(f), 50 Ω

Phase-Stable Test Port Cables, Armored

15NNF50-1.5C 1.5 m, DC to 6 GHz, N(m) to N(f), 50 Ω

15NN50-1.5C 1.5 m, DC to 6 GHz, N(m) to N(m), 50 Ω

15NDF50-1.5C 1.5 m, DC to 6 GHz, N(m) to 7/16 DIN(f), 50 Ω

15ND50-1.5C 1.5 m, DC to 6 GHz, N(m) to 7/16 DIN(m), 50 Ω

15NNF50-3.0C 3.0 m, DC to 6 GHz, N(m) to N(f), 50 Ω

15NN50-3.0C 3.0 m, DC to 6 GHz, N(m) to N(m), 50 Ω

Phase-Stable 18 GHz and 40 GHz Semi-Rigid Cables (Armored)

3670K50-1 0.3 m (12 in), DC to 40 GHz, K(f) to K(m), 50 Ω

3670K50-2 0.6 m (24 in), DC to 40 GHz, K(f) to K(m), 50 Ω

3670N50-1 0.3 m (12 in), DC to 18 GHz, N(f) to N(m), 50 Ω

3670NN50-1 0.3 m (12 in), DC to 18 GHz, N(m) to N(m), 50 Ω

3670N50-2 0.6 m (24 in), DC to 18 GHz, N(f) to N(m), 50 Ω

3670NN50-2 0.6 m (24 in), DC to 18 GHz, N(m) to N(m), 50 Ω

Adapters

1091-26-R SMA(m) to N(m), DC to 18 GHz, 50 Ω

1091-27-R SMA(f) to N(m), DC to 18 GHz, 50 Ω

1091-80-R SMA(m) to N(f), DC to 18 GHz, 50 Ω

1091-81-R SMA(f) to N(f), DC to 18 GHz, 50 Ω

1091-172 BNC(f) to N(m), DC to 1.3 GHz, 50 Ω

510-90-R 7/16 DIN(f) to N(m), DC to 7.5 GHz, 50 Ω

510-91-R 7/16 DIN(f) to N(f), DC to 7.5 GHz, 50 Ω

510-92-R 7/16 DIN(m) to N(m), DC to 7.5 GHz, 50 Ω

510-93-R 7/16 DIN(m) to N(f), DC to 7.5 GHz, 50 Ω

510-96-R 7/16 DIN(m) to 7/16 DIN (m), DC to 7.5 GHz, 50 Ω

510-97-R 7/16 DIN(f) to 7/16 DIN (f), DC to 7.5 GHz, 50 Ω

513-62 Adapter, DC to 18 GHz, TNC(f) to N(f), 50 Ω

1091-315 Adapter, DC to 18 GHz, TNC(m) to N(f), 50 Ω

1091-324 Adapter, DC to 18 GHz, TNC(f) to N(m), 50 Ω

1091-325 Adapter, DC to 18 GHz, TNC(m) to N(m), 50 Ω

1091-317 Adapter, DC to 18 GHz, TNC(m) to SMA(f), 50 Ω

1091-318 Adapter, DC to 18 GHz, TNC(m) to SMA(m), 50 Ω

1091-323 Adapter, DC to 18 GHz, TNC(m) to TNC(f), 50 Ω

1091-326 Adapter, DC to 18 GHz, TNC(m) to TNC(m), 50 Ω

510-102-R N(m) to N(m), DC to 11 GHz, 50 Ω, 90 degrees right angle

34RKNF50 Ruggedized K(m) to N(f), DC to 18 GHz, 50 Ω

MS202xC/MS203xC TDS PN: 11410-00548 Rev. R

25 of 32

Ordering Information

Optional Accessories

(continued)

Precision Adapters

Attenuators N Type

(up to 18 GHz)

Attenuators K Type

(up to 40 GHz)

Directional Antennas

VNA Master MS202xC/MS203xC

Part Number Description

34NN50A Precision Adapter, N(m) to N(m), DC to 18 GHz, 50 Ω

34NFNF50 Precision Adapter, N(f) to N(f), DC to 18 GHz, 50 Ω

34NK50 Precision Adapter, DC to 18 GHz, N(m) to K(m), 50 Ω

34NFKF50 Precision Adapter, DC to 18 GHz, N(m) to K(f), 50 Ω

K220B Precision Adapter, DC to 40 GHz, K(m) to K(m), 50 Ω

K222B Precision Adapter, DC to 40 GHz, K(f) to K(f), 50 Ω

K224B Precision Adapter, DC to 40 GHz, K(m) to K(f), 50 Ω

3-1010-122 20 dB, 5 W, DC to 12.4 GHz, N(m) to N(f)

42N50-20 20 dB, 5 W, DC to 18 GHz, N(m) to N(f)

42N50A-30 30 dB, 5 W, DC to 18 GHz, N(m) to N(f)

3-1010-123 30 dB, 50 W, DC to 8.5 GHz, N(m) to N(f)

1010-127-R 30 dB, 150 W, DC to 3 GHz, N(m) to N(f)

3-1010-124 40 dB, 100 W, DC to 8.5 GHz, N(f) to N(m), Uni-directional

1010-121 40 dB, 100 W, DC to 18 GHz, N(f) to N(m), Uni-directional

1010-128-R 40 dB, 150 W, DC to 3 GHz, N(m) to N(f)

41KB-3 Precision Fixed Attenuator, K(m) to K(f), 3 dB, DC to 26.5 GHz, 50 Ω

41KB-6 Precision Fixed Attenuator, K(m) to K(f), 6 dB, DC to 26.5 GHz, 50 Ω

41KB-10 Precision Fixed Attenuator, K(m) to K(f), 10 dB, DC to 26.5 GHz, 50 Ω

41KB-20 Precision Fixed Attenuator, K(m) to K(f), 20 dB, DC to 26.5 GHz, 50 Ω

41KC-3 Precision Fixed Attenuator, K(m) to K(f), 3 dB, DC to 40 GHz, 50 Ω

41KC-6 Precision Fixed Attenuator, K(m) to K(f), 6 dB, DC to 40 GHz, 50 Ω

41KC-10 Precision Fixed Attenuator, K(m) to K(f), 10 dB, DC to 40 GHz, 50 Ω

41KC-20 Precision Fixed Attenuator, K(m) to K(f), 20 dB, DC to 40 GHz, 50 Ω

2000-1777-R 0.09 MHz to 20 MHz, N(f), –160 dBi to –42 dBi, Log Periodic

2000-1778-R 20 MHz to 200 MHz, N(f), –40 dBi to –3 dBi, Log Periodic

2000-1779-R 200 MHz to 500 MHz, N(f), –13 dBi to –4 dBi, Log Periodic

2000-1659-R 698 MHz to 787 MHz, N(f), 10.1 dBi, Yagi

2000-1411-R 822 MHz to 900 MHz, N(f), 12.1 dBi, Yagi

2000-1412-R 885 MHz to 975 MHz, N(f), 12.3 dBi, Yagi

2000-1660-R 1425 MHz to 1535 MHz, N(f), 14.3 dBi, Yagi

2000-1413-R 1710 MHz to 1880 MHz, N(f), 12.3 dBi, Yagi

2000-1414-R 1850 MHz to 1990 MHz, N(f), 11.4 dBi, Yagi

2000-1416-R 1920 MHz to 2170 MHz, N(f), 14.1 dBi, Yagi

2000-1415-R 2400 MHz to 2500 MHz, N(f), 14.1 dBi, Yagi

2000-1726-R 2500 MHz to 2700 MHz, N(f), 14.1 dBi, Yagi

2000-1715-R 698 MHz to 2500 MHz, N(f), 6 dBi to 7 dBi typical, Bi-Blade

2000-1677-R 300 MHz to 3000 MHz, SMA(m), 50 ohm, 3 m cable (9.8 ft)

0 to 6 dBi gain @ 950 MHz, Log Periodic

2000-1747-R 300 MHz to 5000 MHz, N(f), 4 dBi to 7 dBi typical, Log Periodic

2000-1748-R 1000 MHz to 18000 MHz, N(f), 6 dBi to 7 dBi typical, Log Periodic

26 of 32

PN: 11410-00548 Rev. R MS202xC/MS203xC TDS

VNA Master MS202xC/MS203xC

Optional Accessories

(continued)

Portable Antennas

Mag Mount Broadband Antennas

Ordering Information

Part Number Description

2000-1200-R 806 MHz to 866 MHz, SMA(m), 50 Ω

2000-1473-R 870 MHz to 960 MHz, SMA(m), 50 Ω

2000-1035-R 896 MHz to 941 MHz, SMA(m), 50 Ω (1/2 wave)

2000-1030-R 1710 MHz to 1880 MHz, SMA(m), 50 Ω (1/2 wave)

2000-1474-R 1710 MHz to 1880 MHz with knuckle elbow (1/2 wave)

2000-1031-R 1850 MHz to 1990 MHz, SMA(m), 50 Ω (1/2 wave)

2000-1475-R 1920 MHz to 1980 MHz and 2110 MHz to 2170 MHz, SMA(m), 50 Ω

2000-1032-R 2400 MHz to 2500 MHz, SMA(m), 50 Ω (1/2 wave)

2000-1361-R 2400 MHz to 2500 MHz, 5000 MHz to 6000 MHz, SMA(m), 50 Ω

2000-1751-R 698 MHz to 960 MHz, 1710 MHz to 2100 MHz, 2500 MHz to

2700 MHz, SMA(m), 2 dB typical, 50 Ω

2000-1616 20 MHz to 21000 MHz, N(f), 50 Ω

2000-1487 VHF/UHF, Telescopic Whip antenna, straight or 90°, BNC(m), 50 Ω

2000-1636-R Antenna Kit (Consists of: 2000-1030-R, 2000-1031-R, 2000-1032-R,

2000-1200-R, 2000-1035-R, 2000-1361-R, and carrying pouch)

2000-1647-R Cable 1: 698 MHz to 1200 MHz, 2 dBi peak gain,

1700 MHz to 2700 MHz, 5 dBi peak gain, N(m), 50 Ω, 10 ft

Cable 2: 3000 MHz to 6000 MHz, 5 dBi peak gain, N(m), 50 Ω, 10 ft

Cable 3: GPS 26 dB gain, SMA(m), 50 Ω, 10 ft

2000-1645-R 694 MHz to 894 MHz, 3 dBi peak gain

1700 MHz to 2700 MHz, 3 dBi peak gain, N(m), 50 Ω, 10 ft

2000-1646-R 750 MHz to 1250 MHz, 3 dBi peak gain,

1650 MHz to 2000 MHz, 5 dBi peak gain,

2100 MHz to 2700 MHz, 3 dBi peak gain, N(m), 50 Ω, 10 ft

2000-1648-R 1700 MHz to 6000 MHz, 3 dBi peak gain, N(m), 50 Ω, 10 ft

MS202xC/MS203xC TDS PN: 11410-00548 Rev. R

27 of 32

Ordering Information

Optional Accessories

(continued)

Bandpass Filters

VNA Master MS202xC/MS203xC

Part Number Description

1030-114-R 806 MHz to 869 MHz, N(m) to SMA(f), 50 Ω

1030-109-R 824 MHz to 849 MHz, N(m) to SMA(f), 50 Ω

1030-110-R 880 MHz to 915 MHz, N(m) to SMA(f), 50 Ω

1030-111-R 1850 MHz to 1910 MHz, N(m) to SMA(f), 50 Ω

1030-112-R 2400 MHz to 2484 MHz, N(m) to SMA(f), 50 Ω

1030-105-R 890 MHz to 915 MHz, N(m) to N(f), 50 Ω

1030-106-R 1710 MHz to 1790 MHz, N(m) to N(f), 50 Ω

1030-107-R 1910 MHz to 1990 MHz, N(m) to N(f), 50 Ω

1030-149-R High Pass, 150 MHz, N(m) to N(f), 50 Ω

1030-150-R High Pass, 400 MHz, N(m) to N(f), 50 Ω

1030-151-R High Pass, 700 MHz, N(m) to N(f), 50 Ω

1030-152-R Low Pass, 200 MHz, N(m) to N(f), 50 Ω

1030-153-R Low Pass, 550 MHz, N(m) to N(f), 50 Ω

1030-155-R 2500 MHz to 2700 MHz, N(m) to N(f), 50 Ω

1030-178-R 1920 MHz to 1980 MHz, N(m) to N(f), 50 Ω

1030-179-R 777 MHz to 798 MHz, N(m) to N(f), 50 Ω

1030-180-R 2500 MHz to 2570 MHz, N(m) to N(f), 50 Ω

2000-1684-R 791 MHz to 821 MHz, N(m) to N(f), 50 Ω

2000-1734-R Bandpass Filter, 699 MHz to 715 MHz, N(m) and N(f), 50 Ω

2000-1735-R Bandpass Filter, 776 MHz to 788 MHz, N(m) and N(f), 50 Ω

2000-1736-R Bandpass Filter, 815 MHz to 850 MHz, N(m) and N(f), 50 Ω

2000-1737-R Bandpass Filter, 1711 MHz to 1756 MHz, N(m) and N(f), 50 Ω

2000-1738-R Bandpass Filter, 1850 MHz to 1910 MHz, N(m) and N(f), 50 Ω

2000-1739-R Bandpass Filter, 880 MHz to 915 MHz, N(m) and N(f), 50 Ω

2000-1740-R Bandpass Filter, 1710 MHz to 1785 MHz, N(m) and N(f), 50 Ω

2000-1741-R Bandpass Filter, 1920 MHz to 1980 MHz, N(m) and N(f), 50 Ω

2000-1742-R Bandpass Filter, 832 MHz to 862 MHz, N(m) and N(f), 50 Ω

2000-1743-R Bandpass Filter, 2500 MHz to 2570 MHz, N(m) and N(f), 50 Ω

2000-1799-R Bandpass Filter, 2305 MHz to 2320 MHz, N(m) and N(f), 50 Ω

28 of 32

PN: 11410-00548 Rev. R MS202xC/MS203xC TDS

VNA Master MS202xC/MS203xC Ordering Information

Optional Accessories

(continued)

Related Literature, Application Notes, Manuals

Part Number Description

10580-00244 Spectrum Analyzer Measurement Guide

10580-00240 Power Meter Measurement Guide

10580-00289 VNA Measurement Guide

10580-00305 VNA Master User Guide

10580-00306 VNA Master Programming Manual

10580-00307 VNA Master Maintenance Manual

11410-00206 Time Domain for Vector Network Analyzers

11410-00214 Reflectometer Measurements – Revisited

11410-00270 What is Your Measurement Accuracy?

11410-00373 Distance-to-Fault

11410-00387 Primer on Vector Network Analysis

11410-00414 High Accuracy Power Meter, PSN50

11410-00424 USB Power Sensor MA24106A

11410-00472 Measuring Interference

11410-00476 Essentials of Vector Network Analysis

11410-00504 Microwave USB Power Sensor MA241x8A

11410-00531 Practical Tips on Making “Vector Voltmeter (VVM)” Phase

Measurements using VNA Master (Option 15)

11410-00545 VNA Master + Spectrum Analyzer Brochure

11410-00549 VNA Master + Spectrum Analyzer Technical Data Sheet

11410-00565 Troubleshoot Wire Cable Assemblies with Frequency-Domain

Reflectometry

11410-00700 Evaluation of RF Network Testing

MS202xC/MS203xC TDS PN: 11410-00548 Rev. R

29 of 32

Notes VNA Master MS202xC/MS203xC

30 of 32

PN: 11410-00548 Rev. R MS202xC/MS203xC TDS

VNA Master MS202xC/MS203xC Notes

MS202xC/MS203xC TDS PN: 11410-00548 Rev. R

31 of 32

The Master Users Group is an organization dedicated to providing training, technical support, networking opportunities and links to Master product development teams. As a member you will receive the Insite Quarterly Newsletter with user stories, measurement tips, new product news and more.

Visit us to register today:

www.anritsu.com/mug

Training at Anritsu

Anritsu has designed courses to help you stay up to date with technologies important to your job. For available training courses visit:

www.anritsu.com/training

• United States

Anritsu Company

1155 East Collins Blvd, Suite 100

Richardson, TX 75081, U.S.A.

Toll Free: 1-800-267-4878

Phone: +1-972-644-1777

Fax: +1-972-671-1877

• Canada

Anritsu Electronics Ltd.

700 Silver Seven Road, Suite 120

Kanata, Ontario K2V 1C3, Canada

Phone: +1-613-591-2003

Fax: +1-613-591-1006

• Brazil

Anritsu Electrônica Ltda.

Praça Amadeu Amaral, 27 - 1 Andar

01327-010 Bela Vista, São Paulo, Brazil

Phone: +55-11-3283-2511

Fax: +55-11-3288-6940

• Mexico

Anritsu Company, S.A. de C.V.

Av. Ejército Nacional No. 579 Piso 9, Col. Granada

11520 México, D.F., México

Phone: +52-55-1101-2370

Fax: +52-55-5254-3147

• United Kingdom

Anritsu EMEA Ltd.

200 Capability Green

Luton, Bedfordshire LU1 3LU

United Kingdom

Phone: +44-1582-433280

Fax: +44-1582-731303

• France

Anritsu S.A.

12 Avenue du Québec

Bâtiment Iris 1-Silic 612

91140 Villebon-sur-Yvette, France

Phone: +33-1-60-92-15-50

Fax: +33-1-64-46-10-65

• Germany

Anritsu GmbH

Nemetschek Haus, Konrad-Zuse-Platz 1

81829 München, Germany

Phone: +49-89-442308-0

Fax: +49-89-442308-55

• Italy

Anritsu S.r.l.

Via Elio Vittorini 129

00144 Roma, Italy

Phone: +39-06-509-9711

Fax: +39-06-502-2425

• Sweden

Anritsu AB

Kistagången 20B

164 40 KISTA, Sweden

Phone: +46-8-534-707-00

Fax: +46-8-534-707-30

• Finland

Anritsu AB

Teknobulevardi 3-5

FI-01530 Vantaa, Finland

Phone: +358-20-741-8100

Fax: +358-20-741-8111

• Denmark

Anritsu A/S

Kay Fiskers Plads 9

2300 Copenhagen S, Denmark

Phone: +45-7211-2200

Fax: +45-7211-2210

• Russia

Anritsu EMEA Ltd.

Representation Office in Russia

Tverskaya str. 16/2, bld. 1, 7th floor

Moscow, 125009, Russia

Phone: +7-495-363-1694

Fax: +7-495-935-8962

• Spain

Anritsu EMEA Ltd.

Representation Office in Spain

Edificio Cuzco IV, Po. de la Castellana, 141, Pta. 8

28046, Madrid, Spain

Phone: +34-915-726-761

Fax: +34-915-726-621

• United Arab Emirates

Anritsu EMEA Ltd.

Dubai Liaison Office

P O Box 500413 - Dubai Internet City

Al Thuraya Building, Tower 1, Suite 701, 7th Floor

Dubai, United Arab Emirates

Phone: +971-4-3670352

Fax: +971-4-3688460

• India

Anritsu India Private Limited

2nd & 3rd Floor, #837/1, Binnamangla 1st Stage

Indiranagar, 100ft Road, Bangalore - 560038, India

Phone: +91-80-4058-1300

Fax: +91-80-4058-1301

• Singapore

Anritsu Pte. Ltd.

11 Chang Charn Road, #04-01, Shriro House

Singapore 159640

Phone: +65-6282-2400

Fax: +65-6282-2533

• P.R. China (Shanghai)

Anritsu (China) Co., Ltd.

27th Floor, Tower A

New Caohejing International Business Center

No. 391 Gui Ping Road Shanghai, Xu Hui Di District

Shanghai 200233, P.R. China

Phone: +86-21-6237-0898

Fax: +86-21-6237-0899

• P.R. China (Hong Kong)

Anritsu Company Ltd.

Unit 1006-7, 10/F., Greenfield Tower

Concordia Plaza

No. 1 Science Museum Road, Tsim Sha Tsui East

Kowloon, Hong Kong, P. R. China

Phone: +852-2301-4980

Fax: +852-2301-3545

• Japan

Anritsu Corporation

8-5, Tamura-cho, Atsugi-shi

Kanagawa, 243-0016 Japan

Phone: +81-46-296-1221

Fax: +81-46-296-1238

• Korea

Anritsu Corporation, Ltd.

5FL, 235 Pangyoyeok-ro, Bundang-gu

Seongnam-si

Gyeonggi-do, 463-400 Korea

Phone: +82-31-696-7750

Fax: +82-31-696-7751

• Australia

Anritsu Pty Ltd.

Unit 21/270 Ferntree Gully Road

Notting Hill, Victoria, 3168, Australia

Phone: +61-3-9558-8177

Fax: +61-3-9558-8255

• Taiwan

Anritsu Company Inc.

7F, No. 316, Sec. 1, Neihu Rd, Taipei 114, Taiwan

Phone: +886-2-8751-1816

Fax: +886-2-8751-1817

List Revision Date: 20150420

® Anritsu All trademarks are registered trademarks of their respective companies. Data subject to change without notice.

For the most recent specifications visit: www.anritsu.com

Anritsu utilizes recycled paper and environmentally conscious inks and toner.

MS202xC/MS203xC VNA Master TDS

Copyright June 2015 Anritsu Company, USA

All Rights Reserved

32 of 32