advertisement
Technical Data Sheet
VNA Master
™
Handheld Vector Network Analyzer +
Spectrum Analyzer
MS2026C
5 kHz to 6 GHz
MS2036C
5 kHz to 6 GHz
9 kHz to 9 GHz
MS2027C
5 kHz to 15 GHz
MS2037C
5 kHz to 15 GHz
9 kHz to 15 GHz
MS2028C
5 kHz to 20 GHz Vector Network Analyzer
MS2038C
5 kHz to 20 GHz
9 kHz to 20 GHz
Vector Network Analyzer
Spectrum Analyzer
The Ultimate Handheld Vector Network + Spectrum Analyzer for
Cable, Antenna, and Signal Analysis Anytime, Anywhere
Introduction
High Performance Handheld S-Parameters — Meet the MS202xC/3xC VNA Master + Spectrum Analyzer, the industry’s broadest frequency handheld solution to address cable, antenna, component, and signal analysis needs in the field with frequency coverage from 5 kHz up to 20 GHz. Equally impressive, this broadband measurement tool offers the industry’s first 12-term error correction algorithm in a truly handheld, battery-operated, rugged multi-function instrument. Optional Time Domain with Low Pass Step response and Real Impedance graph delivers standard TDR-type display results. Time Domain also includes a standard gating function.
The MS203xC models include a powerful spectrum analyzer that multiplies user convenience by combining spectrum analysis with the VNA into a single measurement powerhouse for the harsh RF and physical environments of field test.
Whether it is for spectrum monitoring, broadcast proofing, interference analysis, RF and microwave measurements, regulatory compliance, or 3G/4G and wireless data network measurements, this VNA/Spectrum Analyzer combination is the ideal instrument for making fast and reliable measurements in the field.
VNA Master™ MS202xC/MS203xC Vector Network Analyzer + Spectrum Analyzer
Size: 315 mm x 211 mm x 78/97mm (12.4 in x 8.3 in x 3.1/3.8 in), Lightweight: 4.5 kg to 4.8 kg (9.9 lb to 10.5 lb)
Specifications VNA Master MS202xC/MS203xC
Vector Network Analyzer Performance and Functional Highlights (All Models)
• Broadband coverage of 5 kHz to up to 20 GHz
• True 2-path, 2-port Vector Network Analyzer
• Ultimate accuracy with 12-term error correction
• High Performance Handheld S-Parameters
• User-defined Quad Display for viewing all 4 S-Parameters
• Arbitrary data points up to 4001
• IF Bandwidth selections of 10 Hz to 100 kHz
• Directivity:
> 42 dB up to 6 GHz (all models)
> 36 dB > 6 GHz up to 20 GHz (all models)
• Supports Reciprocal Through Calibration types
(SOLR, SSLR, SSSR)
• All models support waveguide measurements
• 350 μs/data point sweep speed
• USB/Ethernet for PC data transfer and control
• Automate repetitive tasks via Ethernet & USB
• Field upgradable firmware
• Operation to +55 ºC: full performance on AC or battery
• Store more than 4000 traces and setups in memory
• Portable: 4.5/4.8 kg (9.9/10.5 lb)
• Time Domain (with gating) option
• Internal Bias Tee option
• Vector Voltmeter option
• High Accuracy Power Meter option
• Differential option (S d1d1
, S
c1c1
, S
d1c1
, and S
c1d1
)
• Secure Data Operation option for safe use in high security
environments
• GPS Receiver option
• Low Pass Stepped Response and Real Impedance graph type
provide TDR functionality (standard capability with
Time Domain option)
• Multiple display formats including Polar and Real Impedance
• Supports Anritsu USB Power Sensors
• 8.4 in, 800 x 600 high resolution, daylight-viewable TFT color
display
• Complies with MIL-PRF-28800F Class 2, Certified for use in
Explosive Atmosphere per MIL-PRF-28800F and
MIL-STD-810G
Spectrum Analyzer Performance and Functional Highlights (MS203XC Models Only)
• Measure: Occupied Bandwidth, Channel Power, ACPR, C/I
• Dynamic Range: > 106 dB in 1 Hz RBW
• DANL: –164 dBm in 1 Hz RBW
• Phase Noise: –106 dBc/Hz @ 10 kHz offset at 1 GHz
• GPS-Enhanced Frequency Accuracy: < ± 25 ppb with GPS On
and locked. GPS-Enhanced Frequency Accuracy is retained after GPS unlock at < 50 ppb for 72 hours, 0 °C to 50 °C
• 1 Hz to 10 MHz Resolution Bandwidth (RBW)
• Traces: Normal, Max Hold, Min Hold, Average, # of Averages
• Detectors: Peak, Negative, Sample, Quasi-peak, and true RMS
• Markers: 6, each with a Delta Marker, or 1 Reference with
6 Deltas
• Limit Lines: up to 40 segments with one-button
envelope creation
• Trace Save-on-Event: crossing limit line or sweep complete
• Option to automatically optimize sweep-RBW-VBW trade-off
for best possible display
• Interference Analyzer Option: Spectrogram, Signal Strength,
RSSI
• Standard Burst Detect: 1000X faster sweep with spans up to
15 MHz. Captures intermittent signals as narrow as 200
μ
S every time.
• GPS tagging of stored traces
• Internal Preamplifier standard
• High Accuracy Power Meter Option
• AM/FM/SSB Demodulation (audio only)
• Optional AM/FM/PM Analyzer
• Optional Coverage Mapping
• Optional Channel Scanner
PN: 11410-00548 Rev. R MS202xC/MS203xC TDS
VNA Master MS202xC/MS203xC Specifications
Table of Contents
Definitions
All specifications and characteristics apply to Revision 2 instruments under the following conditions, unless otherwise stated:
Warm-Up Time After 15 minutes of warm-up time in VNA mode, where the instrument is left in the ON state.
Temperature Range Over the 23 °C ± 5 °C temperature range.
Reference Signal When using internal reference signal.
Spectrum Analyzer After 5 minutes of warm-up time, where the instrument is left in the ON state and
Sweep Mode set to Performance.
Typical Performance Typical specifications that are not in parenthesis are not tested and not warranted. They are generally representative of characteristic performance. Typical specifications in parenthesis ( ) represent the mean value of measured units and do not include any guard-bands or uncertainties. They are not warranted.
Uncertainty A coverage factor of x1 is applied to the "VNA" or "corrected system" measurement uncertainties to facilitate comparison with other industry handheld analyzers.
Calibration Cycle Calibration is within the recommended 12 month period (residual specifications also require calibration kit calibration cycle adherence.)
All specifications subject to change without notice. For the most current data sheet, please visit the Anritsu web site: www.anritsu.com
MS202xC/MS203xC TDS PN: 11410-00548 Rev. R
Specifications VNA Master MS202xC/MS203xC
VNA Performance Specifications
Block Diagram
As shown in the following simplified block diagram, the VNA Master has a 2-port, 2-path architecture that automatically measures four S-parameters with a single connection.
Port 1 S
21
Port 2
S
11
DUT
S
22
S
12
Receiver
Port 1
Receiver
Port 2
Bridge/
Coupler
Reference
Receiver
Bridge/
Coupler
Switch
Source
Frequency
Frequency Range MS2026C/36C: 5 kHz to 6 GHz
MS2027C/37C: 5 kHz to 15 GHz
MS2028C/38C: 5 kHz to 20 GHz
Frequency Accuracy ±1.5 ppm
Frequency Resolution 1 Hz to 375 MHz, 10 Hz to 6 GHz, and 100 Hz to 20 GHz
Test Port Power
typical
VNA Master supports selection of either High (default) or Low test port power. Changing power after calibration can degrade the calibrated performance.
Frequency Range High Port Power (dBm) Low Port Power (dBm)
5 kHz to 3 GHz
> 3 GHz to 6 GHz
> 6 GHz to 20 GHz
+3
–3
–3
–25
–25
–15
Transmission Dynamic Range
The transmission dynamic range (the difference between test port power and noise floor) using 10 Hz IF Bandwidth and High Port Power:
Frequency Range
5 kHz to 2 MHz 85 dB
> 2 MHz to 3 GHz 100 dB
> 3 GHz to 6 GHz 90 dB
> 6 GHz to 20 GHz 85 dB
Sweep Speed
The typical sweep speed in μs/point for IF Bandwidth of 100 kHz, 1001 data points, and single display is shown for the following frequencies. The three receiver architecture will simultaneously collect S
Frequency Range Sweep Speed
21
and S
11
(or S
12
and S
22
) in a single sweep
5 kHz to 6 GHz 350 μs/point typical
> 6 GHz to 20 GHz 650 μs/point typical
High-Level Noise
S
11
or S
22
, Short, Power = High, IFBW = 200 Hz, typical
Frequency Range Magnitude Phase
5 kHz to 6 GHz
> 6 GHz to 20 GHz
0.004 dB (rms)
0.010 dB (rms)
0.040 deg
0.050 deg
Noise Floor
10 Hz IFBW
Frequency Noise Floor
5 kHz to 2 MHz –85 dBm typical
> 2 MHz to 3 GHz –100 dBm typical
> 3 GHz to 6 GHz –96 dBm typical
> 6 GHz to 20 GHz –91 dBm typical
Temperature Stability
S
11
or S
Frequency Range
22
, Short, 23 ºC ± 5 ºC, typical
Magnitude
5 kHz to 10 GHz 0.018 dB/ºC
Phase
0.160 deg/ºC
> 10 GHz to 20 GHz 0.070 dB/ºC 0.800 deg/ºC
PN: 11410-00548 Rev. R MS202xC/MS203xC TDS
VNA Master MS202xC/MS203xC Specifications
VNA Functional Specifications
Measurement Parameters S
11
, S
21
, S
22
, S
12
, (optionally: S d1d1
, S c1c1
, S d1c1
Number of Traces Four: TR1, TR2, TR3, TR4
, S c1d1
)
Trace Format
Graph Types
Single, Dual, Tri, Quad, with Trace overlay capabilities
Log Magnitude, SWR, Phase, Real, Imaginary, Group Delay, Smith Chart,
Inverted Smith Chart (Admittance), Log Mag/2 (1-Port Cable Loss), Linear Polar, Log Polar,
Real Impedance, Imaginary Impedance
Domains Frequency Domain, Distance Domain, Time Domain with gating (Time Domain optional)
Frequency Start Frequency, Stop Frequency, Center Frequency, Span
Distance Start Distance, Stop Distance
Time Start Time, Stop Time
Frequency Sweep Type: Linear Single Sweep, Continuous
Data Points 2 to 4001 (arbitrary setting); data points can be reduced without recalibration.
Limit Lines Upper, Lower, 10-segmented Upper, 10-segmented Lower
Test Limits Pass/Fail for Upper, Pass/Fail for Lower, Limit Audible Alarm
Data Averaging Sweep-by-sweep
Smoothing 0 % to 20 %
IF Bandwidth (Hz) 10, 20, 50, 100, 200, 500, 1k, 2k, 5k, 10k, 20k, 50k, 100k
Reference Plane The reference planes of a calibration (or other normalization) can be changed by entering a line length.
Group Delay Aperture
Assumes no loss, flat magnitude, linear phase, and constant impedance.
Auto Reference Plane Extension Instead of manually entering a line length, this feature automatically adjusts phase shift from the current calibration (or other normalization) to compensate for external cables (or test fixtures). Assumes no loss, flat magnitude, linear phase, and constant impedance.
Defined as the frequency span over which the phase change is computed at a given frequency point. The aperture can be changed without recalibration. The minimum aperture is the frequency range divided by the number of points in calibration and can be increased to 20 % of the frequency range.
Group Delay Range < 180º of phase change within the aperture
Trace Memory A separate memory for each trace can be used to store measurement data for later display. The trace data can be saved and recalled.
Trace Math Complex trace math operations of subtraction, addition, multiplication, or division are provided.
Number of Markers Eight, arbitrary assignments to any trace
Marker Types Reference, Delta
Marker Readout Styles Log Mag, Cable Loss (Log Mag / 2), Log Mag and Phase, Phase, Real and Imaginary, SWR, Impedance,
Admittance, Normalized Impedance, Normalized Admittance, Polar Impedance, and Group Delay, Linear
Mag, Linear Mag and Phase
Marker Search Peak Search, Valley Search, Find Marker Value
Correction Models Full 2-Port, Full S
11
S
11
, Response S
22
Calibration Types Flex, Standard
, Full S
22
, Full S
11
, Response S
11
& S
22
, Response S
21
, Response S
& S
22
, One- Path Two-Port (S
11
,S
21
12
, Response S
21
& S
12
), One-Path Two-Port (S
, Response
22
,S
12
)
Calibration Methods
Calibration Standard Coefficients
Short-Open-Load-Through (SOLT), Offset-Short (SSLT), and Triple-Offset-Short (SSST),
Short-Open-Load-Reciprocal (SOLR), Double-Offset-Short-Load-Reciprocal (SSLR),
Triple-Offset-Short-Reciprocal (SSSR)
Coax: N-Connector, K-Connector, 7/16, TNC, SMA, and four User Defined coax types
Waveguide: WG11A, WG12, WG13, WG14, WG15, WG16, WG17, WG18, WG20, and four User Defined rectangular waveguide types
Cal Correction Toggle On/Off
Interpolation On/Off
Dispersion Compensation Waveguide correction that improves accuracy of distance-to-fault data by compensating for different wavelengths propagating at different speeds.
Impedance Conversion Support for 50 Ω and 75 Ω are provided.
Units Meters, Feet
Bias Tee Settings Internal, External, Off
Timebase Reference Internal, External
File Storage Types Measurement (.mna), Setup (.stp, with or without CAL), S2P (Real/Imag), S2P (Lin Mag/Phase),
S2P (Log Mag/Phase), Text (VNA Only), CSV (VNA Only), JPEG
Ethernet Configuration DHCP or Manual (Static) IP configuration, 10/100 Base-T, RJ45 jack
Languages English, French, German, Spanish, Chinese, Japanese, Korean, Italian, Russian, Portuguese (Português)
MS202xC/MS203xC TDS PN: 11410-00548 Rev. R
Specifications VNA Master MS202xC/MS203xC
Corrected System Performance and Uncertainties — High Port Power
Measurement Accuracy
1
(OSLN50A-18 or TOSLN50A-18)
Frequency Range
5 kHz to 20 MHz
> 20 MHz to 3 GHz
> 3 GHz to 6 GHz
> 6 GHz to 20 GHz
2
Directivity
(dB)
≥ 42
≥ 42
≥ 42
≥ 33
Transmission Uncertainty (S
21
, S
12
)
2
Transmission Magnitude Uncertainty (dB)
10
Source Match
(dB)
≥ 30
≥ 30
≥ 30
≥ 24
100
Load Match
(dB)
≥ 42
≥ 42
≥ 42
≥ 33
Reflection
Tracking (dB)
± 0.02
± 0.07
± 0.05
± 0.2
Transmission Phase Uncertainty (degrees)
Transmission
Tracking
(dB)
± 0.01
± 0.01
± 0.02
± 0.1
1
5 kHz - 20 MHz
20 MHz - 3 GHz
3 GHz - 6 GHz
6 GHz - 20 GHz
10
5 kHz - 20 MHz
20 MHz - 3 GHz
3 GHz - 6 GHz
6 GHz - 20 GHz
1
0.1
0.1
0.01
-80 -70 -60 -50 -40
Transmission Magnitude (dB)
-30
Reflection Uncertainty (S
11
, S
22
)
2
Return Loss Magnitude Uncertainty (dB)
10
-20 -10
5 kHz - 20 MHz
20 MHz - 3 GHz
3 GHz - 6 GHz
6 GHz - 20 GHz
0
0.01
-80 -70 -60 -50 -40
Transmission Magnitude (dB)
-30 -20 -10
100
Return Loss Phase Uncertainty (degrees)
5 kHz - 20 MHz
20 MHz - 3 GHz
3 GHz - 6 GHz
6 GHz - 20 GHz
10
0
1
1
0.1
-40 -35 -30 -25 -20
Return Loss Magnitude (dB)
-15 -10 -5 0
0.1
-40 -35 -30 -25 -20
Return Loss Magnitude (dB)
-15 -10 -5 0
1. Full 2-Port calibration, Default Power, 10 Hz IFBW, No averaging, 10 minute warm-up. OSLN50A-18 or TOSLN50A-18 calibration kit.
Load match specification applicable directly at corrected port only. De-rate by approximately 8 dB if using a 3670 series test port cable.
Reflection and Transmission Tracking are typical.
2. Specified only to 18 GHz, typical above 18 GHz.
PN: 11410-00548 Rev. R MS202xC/MS203xC TDS
VNA Master MS202xC/MS203xC Specifications
Corrected System Performance and Uncertainties — High Port Power
(continued)
Measurement Accuracy
1
(OSLNF50A-18, or TOSLNF50A-18)
Frequency Range
5 kHz to 20 MHz
> 20 MHz to 3 GHz
> 3 GHz to 6 GHz
> 6 GHz to 20 GHz
2
Directivity
(dB)
≥ 42
≥ 42
≥ 42
≥ 33
Transmission Uncertainty (S
21
, S
12
)
2
Transmission Magnitude Uncertainty (dB)
10
Source Match
(dB)
≥ 30
≥ 30
≥ 30
≥ 24
100
Load Match
(dB)
≥ 42
≥ 42
≥ 42
≥ 33
Reflection
Tracking (dB)
± 0.02
± 0.07
± 0.05
± 0.2
Transmission Phase Uncertainty (degrees)
Transmission
Tracking
(dB)
± 0.01
± 0.01
± 0.02
± 0.1
1
5 kHz - 20 MHz
20 MHz - 3 GHz
3 GHz - 6 GHz
6 GHz - 20 GHz
10
5 kHz - 20 MHz
20 MHz - 3 GHz
3 GHz - 6 GHz
6 GHz - 20 GHz
1
0.1
0.1
0.01
-80 -70 -60 -50 -40
Transmission Magnitude (dB)
-30
Reflection Uncertainty (S
11
, S
22
)
2
Return Loss Magnitude Uncertainty (dB)
10
-20 -10
5 kHz - 20 MHz
20 MHz - 3 GHz
3 GHz - 6 GHz
6 GHz - 20 GHz
0
0.01
-80 -70 -60
100
-50 -40
Transmission Magnitude (dB)
-30 -20
Return Loss Phase Uncertainty (degrees)
10
1
1
-10
5 kHz - 20 MHz
20 MHz - 3 GHz
3 GHz - 6 GHz
6 GHz - 20 GHz
0
0.1
-40 -35 -30 -25 -20
Return Loss Magnitude (dB)
-15 -10 -5 0
0.1
-40 -35 -30 -25 -20
Return Loss Magnitude (dB)
-15 -10 -5 0
1. Full 2-Port calibration, Default Power, 10 Hz IFBW, No averaging, 10 minute warm-up. OSLNF50A-18 or TOSLNF50A-18 calibration kit.
Load match specification applicable directly at corrected port only. De-rate by approximately 8 dB if using a 3670 series test port cable.
Reflection and Transmission Tracking are typical.
2. Specified only to 18 GHz, typical above 18 GHz.
MS202xC/MS203xC TDS PN: 11410-00548 Rev. R
Specifications VNA Master MS202xC/MS203xC
Corrected System Performance and Uncertainties — High Port Power
(continued)
Measurement Accuracy
1
(TOSLK50A-20 or TOSLK50A-40)
Frequency Range
5 kHz to 20 MHz
> 20 MHz to 3 GHz
> 3 GHz to 6 GHz
> 6 GHz to 20 GHz
Directivity
(dB)
≥ 42
≥ 42
≥ 42
≥ 36
Source Match
(dB)
≥ 33
≥ 33
≥ 33
≥ 26.5
Load Match
(dB)
≥ 42
≥ 42
≥ 42
≥ 36
Reflection
Tracking (dB)
± 0.02
± 0.07
± 0.05
± 0.2
Transmission Uncertainty (S
21
, S
12
)
Transmission Magnitude Uncertainty (dB)
10 100
Transmission Phase Uncertainty (degrees)
5 kHz - 20 MHz
20 MHz - 3 GHz
3 GHz - 6 GHz
6 GHz - 20 GHz
10
Transmission
Tracking
(dB)
± 0.01
± 0.01
± 0.02
± 0.1
5 kHz - 20 MHz
20 MHz - 3 GHz
3 GHz - 6 GHz
6 GHz - 20 GHz
1
1
0.1
0.1
0.01
-80 -70 -60 -50 -40
Transmission Magnitude (dB)
-30
Reflection Uncertainty (S
11
, S
22
)
Return Loss Magnitude Uncertainty (dB)
10
-20 -10
5 kHz - 20 MHz
20 MHz - 3 GHz
3 GHz - 6 GHz
6 GHz - 20 GHz
0
0.01
-80 -70 -60 -50 -40
Transmission Magnitude (dB)
-30 -20 -10
100
Return Loss Phase Uncertainty (degrees)
5 kHz - 20 MHz
20 MHz - 3 GHz
3 GHz - 6 GHz
6 GHz - 20 GHz
0
10
1
1
0.1
-40 -35 -30 -25 -20
Return Loss Magnitude (dB)
-15 -10 -5 0
0.1
-40 -35 -30 -25 -20
Return Loss Magnitude (dB)
-15 -10 -5 0
1. Full 2-Port calibration, Default Power, 10 Hz IFBW, No averaging, 10 minute warm-up. TOSLK50A-20 or TOSLK50A-40 calibration kit.
Load match specification applicable directly at corrected port only. De-rate by approximately 8 dB if using a 3670 series test port cable.
Reflection and Transmission Tracking are typical.
PN: 11410-00548 Rev. R MS202xC/MS203xC TDS
VNA Master MS202xC/MS203xC Specifications
Corrected System Performance and Uncertainties — High Port Power
(continued)
Measurement Accuracy
1
(TOSLKF50A-20, or TOSLKF50A-40)
Frequency Range
5 kHz to 20 MHz
> 20 MHz to 3 GHz
> 3 GHz to 6 GHz
> 6 GHz to 20 GHz
Directivity
(dB)
≥ 42
≥ 42
≥ 42
≥ 36
Source Match
(dB)
≥ 33
≥ 33
≥ 33
≥ 26.5
Load Match
(dB)
≥ 42
≥ 42
≥ 42
≥ 36
Reflection
Tracking (dB)
± 0.02
± 0.07
± 0.05
± 0.2
Transmission Uncertainty (S
21
, S
12
)
Transmission Magnitude Uncertainty (dB)
10 100
Transmission Phase Uncertainty (degrees)
5 kHz - 20 MHz
20 MHz - 3 GHz
3 GHz - 6 GHz
6 GHz - 20 GHz
10
Transmission
Tracking
(dB)
± 0.01
± 0.01
± 0.02
± 0.1
5 kHz - 20 MHz
20 MHz - 3 GHz
3 GHz - 6 GHz
6 GHz - 20 GHz
1
1
0.1
0.1
0.01
-80 -70 -60 -50 -40
Transmission Magnitude (dB)
-30
Reflection Uncertainty (S
11
, S
22
)
Return Loss Magnitude Uncertainty (dB)
10
-20 -10
5 kHz - 20 MHz
20 MHz - 3 GHz
3 GHz - 6 GHz
6 GHz - 20 GHz
0
0.01
-80 -70 -60
100
-50 -40
Transmission Magnitude (dB)
-30 -20
Return Loss Phase Uncertainty (degrees)
10
1
1
-10
5 kHz - 20 MHz
20 MHz - 3 GHz
3 GHz - 6 GHz
6 GHz - 20 GHz
0
0.1
-40 -35 -30 -25 -20
Return Loss Magnitude (dB)
-15 -10 -5 0
0.1
-40 -35 -30 -25 -20
Return Loss Magnitude (dB)
-15 -10 -5 0
1. Full 2-Port calibration, Default Power, 10 Hz IFBW, No averaging, 10 minute warm-up. TOSLKF50A-20 or TOSLKF50A-40 calibration kit.
Load match specification applicable directly at corrected port only. De-rate by approximately 8 dB if using a 3670 series test port cable.
Reflection and Transmission Tracking are typical.
MS202xC/MS203xC TDS PN: 11410-00548 Rev. R
Specifications VNA Master MS202xC/MS203xC
Distance Domain Specifications
(formerly Option 501, now standard with firmware revision v1.16 or higher)
Distance Domain Analysis is a powerful field test tool to analyze cables for faults, including minor discontinuities that may occur due to a loose connection, corrosion, or other aging effects. By using Frequency Domain Reflectometry (FDR), the VNA Master exploits a user-specified band of full power operational frequencies (instead of DC pulses from TDR approaches) to more precisely identify cable discontinuities. The VNA Master converts
S-parameters from frequency domain into distance domain on the horizontal display axis, using a mathematical computation called Inverse Fourier
Transform. Connect a reflection at the opposite end of the cable, and the discontinuities appear versus distance to reveal any potential maintenance issues. When access to both ends of the cable is convenient, a similar distance domain analysis is available on transmission measurements.
Distance Domain will improve your productivity with displays of the cable in terms of discontinuities versus distance. This readout can then be compared against previous measurements (from stored data) to determine whether any degradations have occurred since installation (or the last maintenance activity). More importantly, you will know precisely where to go to fix the problem and so minimize or prevent downtime of the system.
Round-Trip (reflection)
Fault Resolution (meters) (0.5 x c x Vp) / ∆F; (c is speed of light = 299,792,458 m/s, ∆F is F2 – F1 in Hz)
One-Way (transmission)
Fault Resolution (meters) (c x Vp) / ∆F; (c is speed of light = 299,792,458 m/s, ∆F is F2 – F1 in Hz)
Horizontal Range (meters) 0 to (data points – 1) x Fault Resolution to a maximum of 3000 m (9843 ft)
Windowing Rectangular, Nominal Side Lobe (NSL), Low Side Lobe (LSL), and Minimum Side Lobe (MSL)
Time Domain (Option 2) Specifications
(includes Distance Domain)
The VNA Master can display the S-parameter measurements in the time or distance domain using lowpass or bandpass processing analysis modes.
The broadband frequency coverage coupled with 4001 data points means you can measure discontinuities both near and far with unprecedented clarity for a handheld tool.
With this option, you can simultaneously view S-parameters in frequency, time, and distance domain to quickly identify faults in the field. Advanced features available with this option include step response, phasor impulse, gating, and frequency gated in time. The option includes computational routines that further enhance the Distance Domain results by compensating for cable loss, relative velocity of propagation, and dispersion compensation in waveguide. See the Distance Domain Specifications above.
Option Comparison Table (Distance Domain and Time Domain)
Measurement
Distance-to-Fault
Distance Domain display
Windowing
Distance of Waveguide
Time Domain display
One Way vs. Round Trip Reflection
Phasor Impulse
Impulse Response
Step Response
Low Pass vs. Bandpass
Frequency Gated by Time
Frequency Gated by Distance
Distance Domain
(formerly Option 501)
X
X
X
Option 2
Time Domain
X
X
X
X
X
X
X
X
X
X
X
X
Secure Data Operation (Option 7)
For highly secure data handling requirements, this software option prevents the storing of measurement setup or data information onto any internal file storage location. Instead, setup and measurement information is stored ONLY to the external USB memory location. A simple factory preset prepares the
VNA Master for transportation while the USB memory remains behind in the secure environment. The VNA Master cannot be switched between secure and non-secure operation by the user once configured for secure data operation. With this option enabled, the user can also choose to blank the frequency values displayed on the screen.
PN: 11410-00548 Rev. R MS202xC/MS203xC TDS
VNA Master MS202xC/MS203xC Specifications
Bias Tee (Option 10)
For tower mounted amplifier tests, the MS20x/3xC series with optional internal bias tees can supply both DC and RF signals on the center conductor of the cable during measurements. For frequency sweeps in excess of 2 MHz, the VNA Master can supply internal voltage control from +12 V to +32 V in
0.1 V steps up to 450 mA. To extend battery life, an external power supply can substitute for the internal supply by using the included external bias ports. Both test ports can be configured to supply voltage via this integrated bias tees option. Bias can be directed to VNA Port 1 or Port 2.
Bias Tee Specifications
The VNA Master offers optional integrated bias tee for supplying DC plus RF0 to the DUT as shown in the simplified block diagram. Connectivity is also provided for external supply (instead of internal) to preserve battery consumption.
Frequency Range 2 MHz to 6 GHz (MS20x6C)
2 MHz to 15 GHz (MS20x7C)
2 MHz to 20 GHz (MS20x8C)
Internal Voltage/Current +12 V to +32 V at 450 mA steady rate
Internal Resolution 0.1 V
External Voltage/Current ± 50 V at 500 mA steady rate
Bias Tee Selections Internal, External, Off
Port 1
Port 2
External Bias Input
(±50 V, 500 mA Max)
Internal
Bias Tee
Switch
Internal
Bias Tee
Internal Bias
+12 to +32 V
450 mA Max
RF Test
Source
Switch
Balanced/Differential S-Parameters, 1-Port (Option 77)
As an alternative to a sampling oscilloscope, verifying the performance and identifying discontinuities in high-data-rate differential cables is now possible with the VNA Master. After a full two-port calibration, connect your differential cable directly to the two test ports and reveal the S d1d1
performance, which is essentially differential return loss, or any of the other differential S-Parameters, S c1c1
, S d1c1 used to isolate noise and interference.
, or S c1d1
. With optional time domain, you can convert frequency sweeps to distance. This capability is especially valuable for applications in high data rate cables where balanced data formats are
Vector Voltmeter (Option 15)
A phased array system relies on phase matched cables for nominal performance. For this class of application, the VNA Master offers this special software mode to simplify phase matching cables at a single frequency. The similarity between the popular vector voltmeter and this software mode ensures minimal training is required to phase match cables. Operation is as simple as configuring the display for absolute or relative measurements. The easy-to-read large fonts show either reflection or transmission measurements using impedance, magnitude, or VSWR readouts. For instrument landing system (ILS) or VHF Omni-directional Range (VOR) applications, a table view improves operator efficiency when phase matching up to twelve cables. The
MS202x/3xC solution is superior because the signal source is included internally, precluding the need for an external signal generator.
VVM Specifications
CW Frequency Range 5 kHz to 6 GHz (MS20x6C)
5 kHz to 15 GHz (MS20x7C)
5 kHz to 20 GHz (MS20x8C)
Measurement Display CW, Table (Twelve Entries, Plus Reference)
Measurement Types Return Loss, Insertion
Measurement Format dB/VSWR/Impedance
MS202xC/MS203xC TDS PN: 11410-00548 Rev. R
Specifications VNA Master MS202xC/MS203xC
Spectrum Analyzer Performance Specifications (MS203xC only)
Measurements
Smart Measurements Field Strength (dBm/m
2
, dBV/m, dBmV/m, dBµV/m, V/m, Watt/m
2
, dBW/m
2
, A/m, dBA/m, or Watt/cm
2
)
Occupied Bandwidth (measures 99 % to 1 % power channel of a signal, or N dB from center of signal)
Channel Power (measures the total power in a specified bandwidth)
ACPR (adjacent channel power ratio)
Emission Mask (recall limit lines as emission mask)
Spurious Emissions (measures up to 32 segments with independent setups and limits)
C/I (carrier-to-interference ratio)
AM/FM/SSB Demodulation (AM, wide/narrow FM, upper/lower SSB), (audio only)
Setup Parameters
Frequency Center/Start/Stop, Span, Freq Step, Freq Offset, Signal Standard, Channel #, Channel Increment
Amplitude Reference Level (RL), Scale, Attenuation Auto/Level, RL Offset, Units (dBm, dBV, dBmV, dBµV, Volt, Watt, dBW, A, dBA), Pre-Amp On/Off, Detection (Peak, RMS/Avg, Negative Peak, Sample, Quasi-Peak)
Span Span, Span Up/Down (1-2-5), Full Span, Zero Span, Last Span
Bandwidth RBW, Auto RBW, VBW, Auto VBW, VBW/Avg Type (Linear, Log), RBW/VBW Ratio, Span/RBW Ratio
Impedance 50 Ω, 75 Ω; external pad required for 75 Ω operation
Sweep Functions
Sweep Single/Continuous, Sweep Time, Gated Sweep (see Option 0090)
Sweep Mode Fast (up to 100x faster than Performance), Performance, No FFT, Burst Detect (1000x Fast in 15 MHz span)
Triggers Free Run, External, Video, IF Power, Force Trigger Once
Trigger Parameters Delay, Level, Slope, Hysteresis, Holdoff (availability varies with trigger)
Trace Functions
Traces Up to three Traces (A, B, C), View/Blank, Write/Hold, Trace A/B/C Operations
Trace A Operations Normal, Max Hold, Min Hold, Average, # of Averages, (always the live trace)
Trace B Operations A → B, B ← → C, Max Hold, Min Hold
Trace C Operations A → C, B ← → C, Max Hold, Min Hold, A – B → C, B – A → C, Relative Reference (dB), Scale
Marker Functions
Markers Markers 1-6 each with a Delta Marker, or Marker 1 Reference with Six Delta Markers,
Marker Table (On/Off/Large), All Markers Off
Marker Types Style (Fixed/Tracking), Noise Marker, Frequency Counter Marker
Marker Auto-Position Peak Search, Next Peak (Right/Left), Peak Threshold %, Set Marker to Channel,
Marker Frequency to Center, Delta Marker to Span, Marker to Reference Level
Marker Table 1-6 markers frequency and amplitude, plus delta markers frequency offset and amplitude
Limit Line Functions
Available Spans > 0 Hz
Limit Lines Upper/Lower, On/Off, Edit, Move, Envelope, Advanced, Limit Alarm, Default Limit
Limit Line Edit Frequency, Amplitude, Add Point, Add Vertical, Delete Point, Next Point Left/Right
Limit Line Move To Current Center Frequency, By dB or Hz, To Marker 1, Offset from Marker 1
Limit Line Envelope Create Envelope, Update Amplitude, Number of Points (2-41), Offset, Shape Square/Slope
Limit Line Advanced Type (Absolute/Relative), Mirror, Save/Recall
Save on Event When Limit Crossed
Frequency
Frequency Range (usable to 0 Hz)
MS2036C 9 kHz to 9 GHz
MS2037C 9 kHz to 15 GHz
MS2038C 9 kHz to 20 GHz
Tuning Resolution 1 Hz
Tuning Resolution 1 Hz
Frequency Reference Aging: ± 1.0 x 10
–6
per year for 10 years
Accuracy: ± 0.3 x 10
–6
(25 °C ± 25 °C) plus aging
(see Option 31 for improved frequency reference aging and accuracy)
Auto-sensing External
Frequency Reference (MHz) 1, 1.2288, 1.544, 2.048, 2.4576, 4.8, 4.9152, 5, 9.8304, 10, 13, 19.6608
Sweep Time 7 µs to 3600 s in zero span
Sweep Time Accuracy ± 2 % in zero span
Bandwidth
Resolution Bandwidth (RBW) 1 Hz to 10 MHz in 1–3 sequence ± 10 % (–3 dB bandwidth)
Video Bandwidth (VBW) 1 Hz to 10 MHz in 1–3 sequence (–3 dB bandwidth)
RBW with Quasi-Peak Detection 200 Hz, 9 kHz, 120 kHz (–6 dB bandwidth)
VBW with Quasi-Peak Detection Auto VBW is On, RBW/VBW = 1
VBW/Average Type Linear/Log
PN: 11410-00548 Rev. R MS202xC/MS203xC TDS
VNA Master MS202xC/MS203xC Specifications
Spectrum Analyzer Performance Specifications (MS203xC only)
(continued)
Spectral Purity – SSB Phase Noise
Offset from 1 GHz
10 kHz
100 kHz
1 MHz
10 MHz
Maximum
–102 dBc/Hz
–106 dBc/Hz
–111 dBc/Hz
–123 dBc/Hz
Typical
–106 dBc/Hz
–110 dBc/Hz
–116 dBc/Hz
–129 dBc/Hz
Amplitude Ranges
Dynamic Range >106 dB minimum at 2.4 GHz, 2/3 (TOI-DANL) in 1 Hz RBW
Measurement Range DANL to +30 dBm
Display Range 1 to 15 dB/div in 1 dB steps, ten divisions displayed
Reference Level Range –150 dBm to +30 dBm
Attenuator Resolution 0 to 65 dB, 5.0 dB steps
Reference Level Offset 99.9 dB External Loss to 99.9 dB External Gain
Amplitude Units Log Scale Modes: dBm, dBW, dBV, dBmV, dBμV, dBA
Linear Scale Modes: fV, nV, μV, mV, V, fW, pW, nW, μW, mW, W, pA, nA, μA, mA, A
Maximum Continuous Input +30 dBm Peak typical, ± 50 VDC (≥ 10 dB Attenuation)
+23 dBm Peak typical, ± 50 VDC (< 10 dB Attenuation)
+13 dBm Peak typical, ± 50 VDC (Preamp = On)
Amplitude Accuracy
(excluding effects of VSWR, noise, and spurs)
20 °C to 30 °C
(after 30 minute warm-up)
9 kHz to 100 kHz a
> 100 kHz to 13 GHz
> 13 GHz to 18 GHz
> 18 GHz to 20 GHz
Maximum
±2.3 dB
±1.3 dB
±2.3 dB
– a. Values below 100 kHz are with the preamplifier turned off.
Typical
±0.5 dB
±0.5 dB
±0.5 dB
±1.0 dB
–10 °C to 55 °C
(after 60 minute warm-up)
Maximum
±2.3 dB
±2.3 dB
±3.3 dB
–
Typical
±0.5 dB
±0.5 dB
±0.5 dB
±1.0 dB
Displayed Average Noise Level (DANL)
(RMS Detection, VBW/Avg Type = Log, Ref Level = –20 dBm for Preamp Off and –50 dBm for
Preamp On, Auto Attenuation, Performance Sweep Mode)
Preamp = Off Preamp = On
10 MHz to 4 GHz
> 4 GHz to 9 GHz
> 9 GHz to 13 GHz
> 13 GHz to 20 GHz
Maximum
–145 dBm
–142 dBm
–136 dBm
–138 dBm
Typical
–148 dBm
–145 dBm
–139 dBm
–141 dBm
Maximum
–161 dBm
–159 dBm
–156 dBm
–157 dBm
Typical
–164 dBm
–162 dBm
–159 dBm
–160 dBm
Spurs
(0 dB input attenuation)
Residual Spurs (RF input terminated)
< 13 GHz
13 GHz to 20 GHz
Input-Related Spurious (–30 dBm input) a. Instrument centered on single signal, span < 1.7 GHz
Preamp = Off
Maximum
–90 dBm
–85 dBm
–60 dBc a
Third-Order Intercept (TOI)
(–20 dBm tones 100 kHz apart, 0 dB Attenuation Preamp OFF)
2.4 GHz +14 dBm minimum
50 MHz to 20 GHz +20 dBm typical
P1dB
< 4 GHz +5 dBm nominal
4 GHz to 20 GHz +12 dBm nominal
Second Harmonic Distortion
(0 dB input attenuation, –30 dBm input)
50 MHz –54 dBc maximum
< 4 GHz –60 dBc typical
≥ 4 GHz –75 dBc typical
VSWR
(≥ 10 dB input attenuation)
≤ 20 GHz 1.5:1 typical
Preamp = On
Maximum
–100 dBm
–100 dBm
–70 dBc typical
MS202xC/MS203xC TDS PN: 11410-00548 Rev. R
Specifications VNA Master MS202xC/MS203xC
High Accuracy Power Meter (Option 19)
(requires external USB power sensor)
Amplitude Maximum, Minimum, Offset, Relative On/Off, Units, Auto Scale
Average # of Running Averages, Max Hold
Zero/Cal Zero On/Off, Cal Factor (Center Frequency, Signal Standard)
Limits Limit On/Off, Limit Upper/Lower
Power Sensor Model
Description
Frequency Range
Connector
PSN50
High Accuracy
RF Power Sensor
50 MHz to 6 GHz
Type N(m), 50 Ω
MA24105A
Inline High
Power Sensor
350 MHz to 4 GHz
Type N(f), 50 Ω
MA24106A
High Accuracy
RF Power Sensor
50 MHz to 6 GHz
Type N(m), 50 Ω
MA24108A/18A/26A
Microwave USB
Power Sensor
10 MHz to 8/18/26 GHz
Type N(m), 50 Ω
(8/18 GHz)
Type K(m), 50 Ω
(26 GHz)
–40 dBm to +20 dBm
(0.1 µW to 100 mW)
Dynamic Range
Measurand
Measurement Uncertainty
Data sheet
(for complete specifications)
Notes:
–30 dBm to +20 dBm
(0.001 mW to
100 mW)
True-RMS
± 0.16 dB
1
11410-00414
+3 dBm to +51.76 dBm
(2 mW to 150 W)
True-RMS
± 0.17 dB
2
11410-00621
–40 dBm to +23 dBm
(0.1 µW to 200 mW)
True-RMS
± 0.16 dB
1
11410-00424
True-RMS
± 0.18 dB
3
11410-00504
1. Total RSS measurement uncertainty (0 ºC to 50 ºC) for power measurements of a CW signal greater than –20 dBm with zero mismatch errors.
2. Expanded uncertainty with K=2 for power measurements of a CW signal greater than +20 dBm with a matched load.
Measurement results referenced to the input side of the sensor.
3. Expanded uncertainty with K=2 for power measurements of a CW signal greater than –20 dBm with zero mismatch errors.
Interference Analyzer (Option 25)
Measurements
Spectrum Field Strength
Occupied Bandwidth
Channel Power
Adjacent Channel Power (ACPR)
AM/FM/SSB Demodulation (Wide/Narrow FM, Upper/Lower SSB), (audio out only)
Carrier-to-Interference ratio (C/I)
Spectrogram Collect data up to 3 days
Signal Strength Gives visual and aural indication of signal strength
Received Signal Strength Indicator (RSSI) Collect data up to one week
Interference Mapping Draw multiple bearings of signal strength from GPS location on on-screen map
Pan and Zoom on-screen maps
Support for Anritsu MA2700A Handheld Interference Hunter
Impedance 50 Ω, 75 Ω; external pad required for 75 Ω operation
Channel Scanner (Option 27)
General
Number of Channels 1 to 20 Channels (Power Levels)
Measurements Graph/Table, Max Hold (On/5 s/Off), Frequency/Channel, Current/Maximum, Dual Color
Scanner Scan Channels, Scan Frequencies, Scan Custom List, Scan Script Master™
Amplitude Reference Level, Scale
Custom Scan Number of Channels, Signal Standard & Channel, Frequency, Bandwidth
Frequency Range 9 kHz to 9, 15, or 20 GHz
Frequency Accuracy ± 10 Hz + frequency reference error
Measurement Range –110 dBm to +30 dBm
Impedance 50 Ω, 75 Ω; external pad required for 75 Ω operation
PN: 11410-00548 Rev. R MS202xC/MS203xC TDS
VNA Master MS202xC/MS203xC Specifications
Coverage Mapping (Option 431)
Measurements
Indoor Mapping RSSI, ACPR
Outdoor Mapping RSSI, ACPR
Setup Parameters
Mode Spectrum Analyzer
Frequency Center, Span (ACPR only), Freq Step, Signal Standard, Channel #, Channel Increment
Amplitude Reference Level (RL), Attenuation Auto/Level, RL Offset, Pre-Amp On/Off, Detection
Span RSSI Mode: Zero Span
ACPR Mode: Span, Span Up/Down (1-2-5), Full Span, Last Span
BW RBW, Auto RBW, VBW, Auto VBW, RBW/VBW Ratio, Span/RBW Ratio
Measurement Setup RSSI: Mapping color thresholds
ACPR: Main Ch BW, Adj Ch BW, Ch Spacing, Adjacent Ch dB Offset, Thresholds for Good and Poor main channel levels
Mapping Colors RSSI: Dark Green (Excellent), Light Green (Very Good), Yellow (Good), Orange (Fair), Dark Red (Poor)
ACPR: Dark Green (Good), Yellow (between Good and Poor), Dark Red (Poor)
Point Distance or Time Setup Repeat Type: Time (100 ms to 16 s), Distance (1 m to 10,000 m)
Distance Units: m, ft
Save Points Map Save KML, JPEG, Tab Delimited
Recall Points Map Recall Map, Recall KML Points only, Recall KML Points with Map, Recall Default Grid
Map Types Outdoor (GPS embedded), Indoor (non-GPS embedded). Import maps using the Anritsu easyMap Tools.
Zoomable (.azm) maps are usable, but cannot be zoomed.
GPS Receiver (Option 31)
Setup On/Off, Antenna Voltage 3.3 V/5.0 V, GPS Info
Note: Anritsu 2000-1528-R GPS antenna requires +5 VDC
Anritsu 2000-1652-R GPS antenna requires +3.3 VDC or +5 VDC
Anritsu 2000-1760-R GPS antenna requires +2.5 VDC to +3.7 VDC
GPS Time/Location Indicator UTC Time, Latitude, Longitude, and Altitude on display (UTC Time and Altitude on GPS Info display)
UTC Time, Latitude, Longitude, and Altitude with trace storage
High Frequency Accuracy < ± 2.5 x 10
–8
Hz/Hz with GPS On, 3 minutes after satellite lock in selected mode (GPS Antenna connected)
< ± 5.0 x 10
–8
Hz/Hz for 3 days after GPS lock, 0 °C to 50 °C (GPS Antenna disconnected)
Connector SMA, female
MS202xC/MS203xC TDS PN: 11410-00548 Rev. R
Specifications
AM/FM/PM Signal Analyzer (Option 509, MS203xC only)
VNA Master MS202xC/MS203xC
Measurements
Display
Type
RF Spectrum
(AM/FM/PM)
Graphic
Display
Power (dBm) vs.
Frequency
Numerical
Displays
Carrier Power
Carrier Frequency
Occupied BW
Audio Spectrum
(AM)
Depth (%) vs.
Modulation Frequency
Audio Spectrum
(FM/PM)
Deviation (kHz/rad) vs.
Modulation Frequency
AM Rate
RMS Depth
(Pk-Pk)/2 Depth
SINAD*
THD*
Distortion/Total Vrms*
FM/PM Rate
RMS Deviation
(Pk-Pk)/2 Deviation
SINAD*
THD*
Distortion/Total Vrms*
Audio
Waveform (AM)
Depth (%) vs.
Time
Audio Waveform
(FM/PM)
Deviation (kHz/rad) vs.
Time
Summary
(AM)
Summary
(FM/PM)
None None
AM Rate
RMS Depth
(Pk-Pk)/2 Depth
SINAD*
THD*
Distortion/Total Vrms*
FM/PM Rate
RMS Deviation
(Pk-Pk)/2 Deviation
SINAD*
THD*
Distortion/Total Vrms*
RMS Depth
Peak + Depth
Peak – Depth
(Pk-Pk)/2 Depth
Carrier Power
Carrier Frequency
Occupied Bandwidth
AM Rate
SINAD*
THD*
Distortion/Total Vrms*
RMS Deviation
Peak + Deviation
Peak – Deviation
(Pk-Pk)/2 Deviation
Carrier Power
Carrier Frequency
Occupied Bandwidth
FM/PM Rate
SINAD*
THD*
Distortion/Total Vrms*
* Requires sine wave modulation
Setup Parameters
Frequency Center Freq, Span, Freq Step, Signal Standard, Channel, Channel Increment, Set (measured) Carrier Freq to Center
Amplitude Setup Scale, Power Offset, Adjust Range
Measurements RF Spectrum, Audio Spectrum (demodulated), Audio Waveform (demodulated), Summary, Coverage
Mapping (Option 431 required), Audio Demod (AM/FM only)
Measurement Setup All Measurements: Demod Type (AM, FM, PM), IFBW, Auto IFBW, Squelch Units, Distortion Measurements
(Sinewave or Broadcast)
RF Spectrum: OBW Method, OBW %, OBW dBC
Audio Spectrum: Span, Scale, Squelch Power
Audio Waveform: Sweep Time, Scale, Squelch Power
Summary: Average count, Squelch Power
Coverage Mapping: Measurement (SINAD, Carrier Power, Multiple), Thresholds, Point Distance/Time
Audio Demod: Demod Type (AM, USB, LSB, Widband FM, Narrowband FM), Volume, Squelch
Mapping Colors Dark Green (Excellent), Light Green (Very Good), Orange (Good), Yellow (Fair), Dark Red (Poor)
Marker Six markers with Delta for each, Peak Search, Marker Freq to Center, Marker to Ref Lvl, Marker Table
RF and Modulation Measurements
AM Modulation Rate: ± 1 Hz (< 100 Hz), ± 2 % (> 100 Hz)
Depth: ± 5 % for (Modulation rates 10 Hz to 100 kHz)
FM Modulation Rate: ± 1 Hz (< 100 Hz); ± 2 % (100 Hz to 100 kHz)
Deviation Accuracy: ± 5 % (100 Hz to 100 kHz)**
PM Modulation Rate: ± 1 Hz (< 100 Hz); ± 2 % (100 Hz to 100 kHz)
Deviation Accuracy: ± 5 % (deviation 0 to 93 Rad, rate 10 Hz to 5 kHz)**
IF Bandwidth 1 kHz to 300 kHz in 1-3 sequence
Frequency Span RF Spectrum: 10 kHz to 10 MHz
Audio Spectrum: 2 kHz, 5 kHz, 10 kHz, 20 kHz, 70 kHz, 140 kHz
RBW/VBW 30
Span/RBW 100
Sweep Time 50 µs to 50 ms (Audio Waveform)
** IFBW must be greater than 95 % occupied BW
PN: 11410-00548 Rev. R MS202xC/MS203xC TDS
VNA Master MS202xC/MS203xC Specifications
General Specifications
Setup Parameters
System Status (Temperature, Battery Info, Serial Number, Firmware Version, IP Address, Options Installed)
Self Test, Application Self Test, GPS (see Option 31)
System Options Name, Date and Time, Ethernet Configuration, Brightness, Volume,
Language (English, French, German, Spanish, Chinese, Japanese, Korean, Italian, Russian, Portuguese),
Reset (Factory Defaults, Master Reset, Update Firmware)
File Save, Recall, Delete, Directory Management
Save/Recall Setups, Measurements, Screen Shots JPEG (save only)
Delete Selected File, All Measurements, All Mode Files, All Content
Directory Management Sort Method (Name/Type/Date), Ascend/Descend, Internal/USB, Copy
Internal Trace/Setup Memory Store more than 4000 traces and setups in memory
External Trace/Setup Memory Limited by size of USB Flash drive
Mode Switching Auto-Stores/Recalls most recently used Setup Parameters in the Mode
Connectors
Maximum Input (Damage Level) Vector Network Analyzer Input: +23 dBm, ± 50 VDC (all models)
Spectrum Analyzer Input: +30 dBm, ± 50 VDC (MS203xC models only)
VNA Connectors Type N, female (or ruggedized K female with Option 11, MS20x7C or MS20x8C only) (x2)
Spectrum Analyzer Connectors Type N, female (or ruggedized K female with Option 11, MS2037C or MS2038C only)
Bias Tee Type BNC female (enabled with Option 10) (x2)
Ext Ref Type BNC, female, 10 MHz, ± 10 dBm
GPS SMA female (available with Option 31 GPS)
External Power 5.5 mm barrel connector, 12 VDC to 14.5 VDC, < 5.0 A
LAN Connection RJ48C, 10/100 Mbps, Connect to PC or LAN for Remote Access
USB Interface (2) Type A, Connect Flash Drive and Power Sensor
USB Interface 5-pin mini-B, Connect to PC for data transfer
Headset Jack 3.5 mm 3-wire headset jack
External Trigger BNC, female, TTL 3.3 V or 5 V triggers on positive edge, Maximum Input + 5 VDC
10 MHz Out SMA, female, 50 Ω
Display
Size 8.4 in, daylight viewable color LCD
Resolution 800 x 600
Power
Field replaceable Li-Ion Battery 40 W when powered by factory 7500 mAh Li-Ion battery (part number: 633-75)
AC/DC Power Adapter 55 W when powered by supplied universal 110/220 V AC/DC adaptor while charging battery
Life-time Charging Cycles > 300 (80 % of initial capacity)
Battery Operation
Battery Charging Limits
3.0 hours typical
0 °C to +45 °C, Relative Humidity ≤ 80 %, non-condensing
Size and Weight
Dimensions Height: 211 mm (8.3 in)
Width: 315 mm (12.4 in)
Depth: 78 mm (3.1 in) (MS202xC), 97 mm (3.8 in) (MS203xC)
Weight, Including Battery 4.5 kg (9.9 lb) (MS202xC), 4.8 kg (10.5 lb) (MS203xC)
Warranty
Duration Standard three-year warranty (one year warranty on battery)
MS202xC/MS203xC TDS PN: 11410-00548 Rev. R
Specifications VNA Master MS202xC/MS203xC
General Specifications
(continued)
Safety
Safety Class EN 61010-1 Class 1
Product Safety IEC 60950-1 when used with Anritsu-supplied Power Supply
Electromagnetic Compatibility
European Union CE Mark, EMC Directive 89/336/EEC, 92/31/EEC, 93/68/EEC and
Low Voltage Directive 73/23/EEC, 93/68/EEC
Interference EN 61326-1
Emissions EN 55011
Immunity EN 61000-4-2/-4-3/-4-4/-4-5/-4-6/-4-11
Australia and New Zealand C-tick N274
Environmental
MIL-PRF-28800F, Class 2
Temperature, operating (ºC)
(3.8.2.1 & 4.5.5.14) Passed, –10 ºC to 55 ºC, relative humidity 85 % non-condensing
Temperature, not operating (ºC)
(3.8.2.2 & 4.5.5.1) Passed, –51 ºC to 71 ºC
Relative humidity (3.8.2.3 & 4.5.5.1) Passed
Altitude, not operating (3.8.3 & 4.5.5.2) Passed, 4600 m (Qualified by similarity — tested on a similar product)
Altitude, operating (3.8.3 & 4.5.5.2) Passed, 4600 m (Qualified by similarity — tested on a similar product)
Vibration limits (3.8.4.1 & 4.5.5.3.1) Passed
Shock, functional (3.8.5.1 & 4.5.5.4.1) Passed
Transit Drop (3.8.5.2 & 4.5.5.4.2) Passed
Bench handling (3.8.5.3 & 4.5.5.4.3) Passed
Shock, high impact (3.8.5.4 & 4.5.5.4.4) Not Required (Not defined in standard; must be invoked and defined by purchase description)
Salt exposure structural parts
(3.8.8.2 & 4.5.6.2.2) Not required for Class 2 equipment
Explosive Atmosphere
MIL-PRF-28800F, Section 4.5.6.3
Passed
MIL-STD-810G,
Method 511.5, Procedure 1 Passed
PN: 11410-00548 Rev. R MS202xC/MS203xC TDS
VNA Master MS202xC/MS203xC Specifications
Line Sweep Tools™
(for your PC)
Trace Capture
Browse to Instrument
Open Legacy Files
View and copy traces from the test equipment to your PC using Windows Explorer
Open DAT files captured with Handheld Software Tools v6.61
Open Current Files Open VNA or DAT files
Capture Plots To The Line Sweep Tools screen, DAT files, Database, or JPEG
Traces
Trace Types
Trace Formats
Return Loss, VSWR, DTF-RL, DTF-VSWR, Cable Loss, Smith Chart, and PIM
DAT, VNA, CSV, PNG, BMP, JPG, HTML, Data Base, and PDF
Report Generation
Report Generator Includes GPS location along with measurements
Report Format Create reports in HTML or PDF format
Report Setup Report Title, Company, Prepared for, Location, Date and Time, Filename, Company logo
Trace Setup 1 Trace Portrait Mode, 2 Trace Portrait Mode, 1 Trace Landscape Mode
Trace Validation
Presets 7 presets allow “one click” setting of up to 6 markers and one limit line
Marker Controls 6 regular Markers, Marker Peak, Marker Valley, Marker between, and frequency entry
Delta Markers 6 Delta markers
Limit Line Enable and drag or value entry. Also works with presets
Next Trace Button Next Trace and Previous Trace arrow keys allow quick switching between traces
Tools
Cable Editor Allows creation of custom cable parameters
Distance to Fault Converts a Return Loss trace to a Distance to Fault trace
Measurement Calculator Converts Real, Imaginary, Magnitude, Phase, RL, VSWR, Rho, and Transmit power
Signal Standard Editor Creates new band and channel tables
Renaming Grid 36 user-definable phrases for creation of file names, trace titles, and trace subtitles
Connectivity
Connections Connect to PC using Serial, USB, or Ethernet
Download Download measurements and live traces to PC for storage and analysis
Upload Upload measurements from PC to instrument
Master Software Tools
(for your PC)
Measurement Viewing
Display Modify display settings, including scale
Spectrum Traces Add, delete, and modify limit lines and markers. Overlay traces.
Spectrum Analyzer Measurements Field Strength, Occupied Bandwidth, Channel Power, ACPR, Emission Mask, C/I
1
Interference Analyzer Measurements Spectrograms, Signal Strength Meter, RSSI
2
Non-Spectrum Measurements Hi Accuracy Power Meter, Channel Scanner, GSM, WCDMA/HSPA, LTE, TD-LTE, TD-SCDMA, CDMA, EV-DO,
Fixed WiMAX, Mobile WiMAX, Screen captures (JPEGs)
1. Spurious Emissions results viewable in a browser
2. Coverage and Interference Mapping files are viewable in a spreadsheet, Google Earth, or Google Maps.
Database Management
Full Trace Retrieval Retrieve all traces from instrument into one PC directory (limited to approximately 15,000 files)
Trace Catalog Index all traces in selected folder & subfolder on PC into one catalog
Trace Rename Utility Rename measurement traces
Group Edit Titles, subtitles, plot scaling, markers and limit lines, simultaneously on similar files
Data Analysis
Trace Math and Smoothing Compare multiple traces
Measurement Calculator Translate into other units
Report Generation
Report Generator Includes GPS, power level, and measurements
Edit Graph Change scale, limit lines, and markers
Report Format Create reports in HTML
Export Measurements Export measurements or entire folders to *.jpg or *.csv format
Notes Annotate measurements
Mapping
(GPS required on instrument)
Spectrum Analyzer Mode MapInfo
LTE Mode Google Earth, Google Maps
MS202xC/MS203xC TDS PN: 11410-00548 Rev. R
Specifications VNA Master MS202xC/MS203xC
Master Software Tools
(continued)
Spectrogram
(Spectrum Monitoring for Interference Analysis and Spectrum Clearing)
Source Recorded Spectrogram or multiple spectrum traces
Folder Spectrogram 2D View creates a composite file of multiple traces
Available Displays Spectrogram, Peak Power vs. Time, Variation in Total Power vs. Time, Peak Frequency vs. Time, Number of
Traces Saved vs. Time (useful with Save on Limit Exceeded), Maximum/Average/Minimum Power vs. Time
File Filter (Violations over limit lines or deviations from averages)
Playback
Display Functions per Trace Markers, GPS location altitude and time (when recorded), instrument time
Filename per trace for Folder Spectrogram
Export to Video Create AVI file of 2D Spectrogram for management review/reports
Export to 3D Spectrogram Views (Set Threshold, Markers)
- 3D (Rotate X, Y, Z Axis, Level Scale, Signal ID)
- 2D (Frequency or Time Domain, Signal ID)
- Top Down
Playback (Frequency and/or Time Domain)
List/Parameter Editors
Antennas, Cables, Signal Standards Modify instrument’s Antenna, Cable, and Signal Standard List
Pass/Fail Create, download, or edit Signal Analysis Pass/Fail Limits
Script Master Create Script Master files for GSM/WCDMA or Channel Scanner
Languages Modify non-English language menus
Mobile WiMAX DL-MAP Parameters
Connectivity
Connections Connect to PC using USB, LAN, or Direct Ethernet connection
Network Search Find all Anritsu handheld instruments on local network
Download Download measurements and live traces to PC for storage and analysis
Upload Upload measurements and other files from PC to instrument
Remote Access Tool Remote control and monitoring of instrument (via Ethernet port) over the Internet
Export Measurements can be saved in various formats, depending on the measurement type, including JPEG, CSV, and Anritsu DAT format
Printing Print individual or all measurement screens
PN: 11410-00548 Rev. R MS202xC/MS203xC TDS
VNA Master MS202xC/MS203xC Ordering Information
Ordering Information
VNA Master™ Handheld Vector Network Analyzer + Spectrum Analyzer
Includes standard three-year warranty and Certificate of Calibration and Conformance.
MS2026C MS2027C MS2028C MS2036C MS2037C MS2038C
5 kHz to 6 GHz 5 kHz to 15 GHz 5 kHz to 20 GHz 5 kHz to 6 GHz
9 kHz to 9 GHz
5 kHz to 15 GHz
9 kHz to 15 GHz
5 kHz to 20 GHz
9 kHz to 20 GHz
Description
Vector Network Analyzer
Spectrum Analyzer
MS2026C-0002 MS2027C-0002 MS2028C-0002 MS2036C-0002 MS2037C-0002 MS2038C-0002 Time Domain (includes
Distance Domain capabilities)
MS2026C-0007 MS2027C-0007 MS2028C-0007 MS2036C-0007 MS2037C-0007 MS2038C-0007 Secure Data Operation
MS2026C-0010 MS2027C-0010 MS2028C-0010 MS2036C-0010 MS2037C-0010 MS2038C-0010 Built-in Bias-Tee
MS2027C-0011 MS2028C-0011 MS2037C-0011 MS2038C-0011 K(f) Test Port Connectors
(MS20x7C & MS20x8C only)
MS2026C-0015 MS2027C-0015 MS2028C-0015 MS2036C-0015 MS2037C-0015 MS2038C-0015 Vector Voltmeter
MS2026C-0019 MS2027C-0019 MS2028C-0019 MS2036C-0019 MS2037C-0019 MS2038C-0019 High Accuracy Power Meter
(requires external USB sensor)
MS2036C-0025 MS2037C-0025 MS2038C-0025 Interference Analysis, a
9 kHz to 9/15/20 GHz
MS2036C-0027 MS2037C-0027 MS2038C-0027 Channel Scanner, a
9 kHz to 9/15/20 GHz
MS2026C-0031 MS2027C-0031 MS2028C-0031 MS2036C-0031 MS2037C-0031 MS2038C-0031 GPS Receiver (requires GPS antenna,
2000-1528-R, 2000-1652-R, or
2000-1760-R)
MS2026C-0077 MS2027C-0077 MS2028C-0077 MS2036C-0077 MS2037C-0077 MS2038C-0077 Balanced/Differential S-Parameters,
1-Port
MS2036C-0431 MS2037C-0431 MS2038C-0431 Coverage Mapping b
MS2026C-0098 MS2027C-0098 MS2028C-0098 MS2036C-0098 MS2037C-0098 MS2038C-0098 Standard Calibration
(ISO 17025 and Z540.1)
MS2026C-0099 MS2027C-0099 MS2028C-0099 MS2036C-0099 MS2037C-0099 MS2038C-0099 Premium Calibration
(ISO 17025 and Z540.1 plus test data)
MS2036C-0509 MS2037C-0509 MS2038C-0509 AM/FM/PM Analyzer c a. Option 31 (GPS) is recommended.
b. Requires Option 31 (GPS) for full functionality.
c. Requires Option 431 (Coverage Mapping) for full functionality.
Standard Accessories
(included with instrument)
Part Number Description
10920-00060 Anritsu Handheld Instruments Documentation Disc
2000-1685-R Soft Carrying Case (supplied with MS202xC only)
2000-1686-R Soft Carrying Case (supplied with MS203xC only)
2300-577 Anritsu Software Tool Box for Handheld RF Instruments Disc
633-75 Rechargeable Li-Ion Battery
40-187-R AC-DC Adapter
806-141-R Automotive Power Adapter, 12 VDC, 60 W
633-75 Rechargeable Li-Ion Battery
3-2000-1498 USB A/5-pin Mini-B Cable, 3.05 m (10 ft)
2000-1371-R Ethernet Cable, 2.13 m (7 ft)
Certificate of Calibration and Conformance
MS202xC/MS203xC TDS PN: 11410-00548 Rev. R
Ordering Information
Optional Accessories
Miscellaneous Accessories
Backpack and Transit Case
VNA Master MS202xC/MS203xC
MA2700A Handheld Interference Hunter (For full specifications, refer to the
MA2700A Technical Data Sheet 11410-00692)
2000-1371-R Ethernet Cable, 2.1 m (7 ft)
3-806-152 Cat 5e Crossover Patch Cable, 2.1 m (7 ft)
633-75 Rechargeable Li-Ion Battery, 7500 mAh
66864 Rack Mount Kit
2000-1689 EMI Near Field Probe Kit
2300-517 Phase Noise Measurement Software
67135 Anritsu Backpack (For Handheld Instrument and PC)
760-243-R Large Transit Case with Wheels and Handle
760-261-R Transit Case, space for MA2700A, antennas, filters, instrument inside softcase, and other interference hunting accessories/tools
760-271-R Transit Case for Portable Directional Antennas and Port Extender
(2000-1777-R, 2000-1778-R, 2000-1779-R, 2000-1798-R)
GPS Antennas
(active)
2000-1652-R Magnet Mount, SMA(m), 3 VDC to 5 VDC with 1 ft cable
2000-1528-R Magnet Mount, SMA(m), 3 VDC to 5 VDC with 4.6 m (15 ft) extension cable
2000-1760-R Mini GPS Antenna, SMA(m), 25 dB gain, 2.5 VDC to 3.7 VDC
Power Sensors
(For complete ordering information see the respective datasheets of each sensor)
PSN50 High Accuracy RF Power Sensor, 50 MHz to 6 GHz, +20 dBm
MA24105A Inline Power Sensor, 350 MHz to 4 GHz, +3 dBm to +51.76 dBm
MA24106A High Accuracy RF Power Sensor, 50 MHz to 6 GHz, +23 dBm
MA24108A Microwave USB Power Sensor, 10 MHz to 8 GHz, +20 dBm
MA24118A Microwave USB Power Sensor, 10 MHz to 18 GHz, +20 dBm
MA24126A Microwave USB Power Sensor, 10 MHz to 26 GHz, +20 dBm
MA25100A RF Power Indicator
PN: 11410-00548 Rev. R MS202xC/MS203xC TDS
VNA Master MS202xC/MS203xC Ordering Information
Optional Accessories
(continued)
Full Temperature Coaxial Calibration Kits
(–10 °C to +55 °C , K Type is compatible with 3.5 mm and SMA connectors see individual data sheets on www.anritsu.com)
OSLN50A-8 High Performance Type N(m), DC to 8 GHz, 50 Ω
OSLNF50A-8 High Performance Type N(f), DC to 8 GHz, 50 Ω
TOSLN50A-8 High Performance with Through Type N(m), DC to 8 GHz, 50 Ω
TOSLNF50A-8 High Performance with Through Type N(f), DC to 8 GHz, 50 Ω
OSLN50A-18 High Performance Type N(m), DC to 18 GHz, 50 Ω
OSLNF50A-18 High Performance Type N(f), DC to 18 GHz, 50 Ω
TOSLN50A-18 High Performance with Through Type N(m), DC to 18 GHz, 50 Ω
TOSLNF50A-18 High Performance with Through Type N(f), DC to 18 GHz, 50 Ω
TOSLK50A-20 High Performance with Through Type K(m), DC to 20 GHz, 50 Ω
TOSLKF50A-20 High Performance with Through Type K(f), DC to 20 GHz, 50 Ω
TOSLK50A-40 High Performance with Through Type K(m), DC to 40 GHz, 50 Ω
TOSLKF50A-40 High Performance with Through Type K(f), DC to 40 GHz, 50 Ω
Coaxial Calibration Components, N Type 50 Ω, K Type 50 Ω
(K Type is compatible with 3.5 mm and SMA connectors)
22N50 Precision Open/Short, N(m), DC to 18 GHz, 50 Ω
22NF50 Precision Open/Short, N(f), DC to 18 GHz, 50 Ω
28N50-2 Precision Load, N(m), DC to 18 GHz, 50 Ω
28NF50-2 Precision Load, N(f), DC to 18 GHz, 50 Ω
22K50 Precision Open/Short, K(m), DC to 40 GHz, 50 Ω
22KF50 Precision Open/Short, K(f), DC to 40 GHz, 50 Ω
28K50 Precision Load, K(m), DC to 40 GHz, 50 Ω
28KF50 Precision Load, K(f), DC to 40 GHz, 50 Ω
Coaxial Calibration Components, Other 50 Ω, 75 Ω
2000-1618-R Open/Short/Load, 7/16 DIN(m), DC to 6.0 GHz 50 Ω
2000-1619-R Open/Short/Load, 7/16 DIN(f), DC to 6.0 GHz 50 Ω
12N50-75B Matching Pad, DC to 3 GHz, 50 Ω to 75 Ω
22N75 Open/Short, N(m), DC to 3 GHz, 75 Ω
22NF75 Open/Short, N(f), DC to 3 GHz, 75 Ω
26N75A Precision Termination, N(m), DC to 3 GHz, 75 Ω
26NF75A Precision Termination, N(f), DC to 3 GHz, 75 Ω
SM/PL-1 Precision N(m) Load, 42 dB, 6 GHz
SM/PLNF-1 Precision N(f) Load, 42 dB, 6 GHz
1091-55-R Open, TNC(f), DC to 18 GHz
1091-53-R Open, TNC(m), DC to 18 GHz
1091-56-R Short, TNC(f), DC to 18 GHz
1091-54-R Short, TNC(m), DC to 18 GHz
1015-54-R Termination, TNC(f), DC to 18 GHz
1015-55-R Termination, TNC(m), DC to 18 GHz
MS202xC/MS203xC TDS PN: 11410-00548 Rev. R
Ordering Information VNA Master MS202xC/MS203xC
Optional Accessories
(continued)
Waveguide Calibration Components and WG/Coaxial Adapters, Rectangular Type 50 Ω
Recommended waveguide calibration procedure requires two offset shorts and a precision load. The waveguide/coax adapter, shown attached to test port #1, adapts the VNA Master test ports to the waveguide under test.
Frequency Range
(GHz)
3.30 to 4.90
3.95 to 5.85
5.85 to 8.20
7.05 to 10.00
8.20 to 12.40
10.00 to 15.00
12.40 to 18.00
17.00 to 26.50
26.50 to 40.00
3.30 to 4.90
3.95 to 5.85
5.85 to 8.20
7.05 to 10.00
8.20 to 12.40
10.00 to 15.00
12.40 to 18.00
17.00 to 26.50
1/8 Offset
23UA229
23UA187
23UA137
23UA112
23UA90
23UA75
23UA62
23UA42
23UA28
23UM40
23UM48
23UM70
23UM84
23UM100
23UM120
23UM140
23UM220
3/8 Offset
24UA229
24UA187
24UA137
24UA112
24UA90
24UA75
24UA62
24UA42
24UA28
24UM40
24UM48
24UM70
24UM84
24UM100
24UM120
24UM140
24UM220
Termination
26UA229
26UA187
26UA137
26UA112
26UA90
26UA75
26UA62
26UA42
26UA28
26UM40
26UM48
26UM70
26UM84
26UM100
26UM120
26UM140
26UM220
Coax to Waveguide
Adapter
35UA229N
35UA187N
Compatible Flanges
PDR40
CPR187F, CPR187G, UG-1352/U, UG-1353/U,
UG-1728/U, UG-1729/U, UG-148/U, UG-149A/U
35UA137N
35UA112N
35UA90N
35UA75N
35UA62N
35UA42K
35UA28K
35UM40N
35UM48N
35UM70N
35UM84N
35UM100N
35UM120N
35UM140N
35UM220K
CPR137F, CPR137G, UG-1356/U, UG-1357/U,
UG-1732/U, UG-1733/U, UG-343B/U, UG-344/U,
UG-440B/U, UG-441/U
CPR112F, CPR112G, UG-1358/U, UG-1359/U,
UG-1734/U, UG-1735/U, UG-52B/U, UG-51/U,
UG-137B/U, UG-138/U
CPR90F, CPR90G, UG-1360/U, UG-1361/U, UG-1736/U,
UG-1737/U, UG-40B/U, UG-39/U, UG-135/U, UG-136B/U
UBR120
UG-541A/U, UG-419/U, UG-1665/U, UG1666/U
UG-596A/U, UG-595/U, UG-597/U, UG-598A/U
UG-599/U
PDR40
CAR48, PAR48, UAR48, PDR48
CAR70, PAR70, UAR 70, PDR70
CBR84, UBR84, PBR84, PDR84
CBR100, UBR100, PBR100, PDR100
CBR120, UBR120, PBR120, PDR120
CBR140, UBR140, PBR140, PDR140
CBR220, UBR220, PBR220, PDR220
* For Coaxial/Waveguide Adapter part numbers, N designates Type N and K designates K-Connector
PN: 11410-00548 Rev. R MS202xC/MS203xC TDS
VNA Master MS202xC/MS203xC Ordering Information
Optional Accessories
(continued)
Phase-Stable Test Port Extension Cables (Armored and Flexible)
Part Number Description
14KFKF50-0.6 0.6 m (24 in), DC to 40 GHz, K(f) to K(f), 50 Ω
14KFKF50-1.0 1.0 m (39 in), DC to 40 GHz, K(f) to K(f), 50 Ω
14KFK50-0.6 0.6 m (24 in), DC to 40 GHz, K(f) to K(m), 50 Ω
14KFK50-1.0 1.0 m (39 in), DC to 40 GHz, K(f) to K(m), 50 Ω
15NN50-1.0B 1.0 m (39 in), DC to 18 GHz, N(m) to N(m), 50 Ω
15NNF50-1.0B 1.0 m (39 in), DC to 18 GHz, N(m) to N(f), 50 Ω
15LL50-1.0A 1.0 m (39 in), DC to 20 GHz, 3.5 mm(m) to 3.5 mm(m), 50 Ω
15LLF50-1.0A 1.0 m (39 in), DC to 20 GHz, 3.5 mm(m) to 3.5 mm(f), 50 Ω
15KK50-1.0A 1.0 m (39 in), DC to 26.5 GHz, K(m) to K(m), 50 Ω
15KKF50-1.0A 1.0 m (39 in), DC to 26.5 GHz, K(m) to K(f), 50 Ω
Phase-Stable Test Port Cables, Armored
15NNF50-1.5C 1.5 m, DC to 6 GHz, N(m) to N(f), 50 Ω
15NN50-1.5C 1.5 m, DC to 6 GHz, N(m) to N(m), 50 Ω
15NDF50-1.5C 1.5 m, DC to 6 GHz, N(m) to 7/16 DIN(f), 50 Ω
15ND50-1.5C 1.5 m, DC to 6 GHz, N(m) to 7/16 DIN(m), 50 Ω
15NNF50-3.0C 3.0 m, DC to 6 GHz, N(m) to N(f), 50 Ω
15NN50-3.0C 3.0 m, DC to 6 GHz, N(m) to N(m), 50 Ω
Phase-Stable 18 GHz and 40 GHz Semi-Rigid Cables (Armored)
3670K50-1 0.3 m (12 in), DC to 40 GHz, K(f) to K(m), 50 Ω
3670K50-2 0.6 m (24 in), DC to 40 GHz, K(f) to K(m), 50 Ω
3670N50-1 0.3 m (12 in), DC to 18 GHz, N(f) to N(m), 50 Ω
3670NN50-1 0.3 m (12 in), DC to 18 GHz, N(m) to N(m), 50 Ω
3670N50-2 0.6 m (24 in), DC to 18 GHz, N(f) to N(m), 50 Ω
3670NN50-2 0.6 m (24 in), DC to 18 GHz, N(m) to N(m), 50 Ω
Adapters
1091-26-R SMA(m) to N(m), DC to 18 GHz, 50 Ω
1091-27-R SMA(f) to N(m), DC to 18 GHz, 50 Ω
1091-80-R SMA(m) to N(f), DC to 18 GHz, 50 Ω
1091-81-R SMA(f) to N(f), DC to 18 GHz, 50 Ω
1091-172 BNC(f) to N(m), DC to 1.3 GHz, 50 Ω
510-90-R 7/16 DIN(f) to N(m), DC to 7.5 GHz, 50 Ω
510-91-R 7/16 DIN(f) to N(f), DC to 7.5 GHz, 50 Ω
510-92-R 7/16 DIN(m) to N(m), DC to 7.5 GHz, 50 Ω
510-93-R 7/16 DIN(m) to N(f), DC to 7.5 GHz, 50 Ω
510-96-R 7/16 DIN(m) to 7/16 DIN (m), DC to 7.5 GHz, 50 Ω
510-97-R 7/16 DIN(f) to 7/16 DIN (f), DC to 7.5 GHz, 50 Ω
513-62 Adapter, DC to 18 GHz, TNC(f) to N(f), 50 Ω
1091-315 Adapter, DC to 18 GHz, TNC(m) to N(f), 50 Ω
1091-324 Adapter, DC to 18 GHz, TNC(f) to N(m), 50 Ω
1091-325 Adapter, DC to 18 GHz, TNC(m) to N(m), 50 Ω
1091-317 Adapter, DC to 18 GHz, TNC(m) to SMA(f), 50 Ω
1091-318 Adapter, DC to 18 GHz, TNC(m) to SMA(m), 50 Ω
1091-323 Adapter, DC to 18 GHz, TNC(m) to TNC(f), 50 Ω
1091-326 Adapter, DC to 18 GHz, TNC(m) to TNC(m), 50 Ω
510-102-R N(m) to N(m), DC to 11 GHz, 50 Ω, 90 degrees right angle
34RKNF50 Ruggedized K(m) to N(f), DC to 18 GHz, 50 Ω
MS202xC/MS203xC TDS PN: 11410-00548 Rev. R
Ordering Information
Optional Accessories
(continued)
Precision Adapters
Attenuators N Type
(up to 18 GHz)
Attenuators K Type
(up to 40 GHz)
Directional Antennas
VNA Master MS202xC/MS203xC
Part Number Description
34NN50A Precision Adapter, N(m) to N(m), DC to 18 GHz, 50 Ω
34NFNF50 Precision Adapter, N(f) to N(f), DC to 18 GHz, 50 Ω
34NK50 Precision Adapter, DC to 18 GHz, N(m) to K(m), 50 Ω
34NFKF50 Precision Adapter, DC to 18 GHz, N(m) to K(f), 50 Ω
K220B Precision Adapter, DC to 40 GHz, K(m) to K(m), 50 Ω
K222B Precision Adapter, DC to 40 GHz, K(f) to K(f), 50 Ω
K224B Precision Adapter, DC to 40 GHz, K(m) to K(f), 50 Ω
3-1010-122 20 dB, 5 W, DC to 12.4 GHz, N(m) to N(f)
42N50-20 20 dB, 5 W, DC to 18 GHz, N(m) to N(f)
42N50A-30 30 dB, 5 W, DC to 18 GHz, N(m) to N(f)
3-1010-123 30 dB, 50 W, DC to 8.5 GHz, N(m) to N(f)
1010-127-R 30 dB, 150 W, DC to 3 GHz, N(m) to N(f)
3-1010-124 40 dB, 100 W, DC to 8.5 GHz, N(f) to N(m), Uni-directional
1010-121 40 dB, 100 W, DC to 18 GHz, N(f) to N(m), Uni-directional
1010-128-R 40 dB, 150 W, DC to 3 GHz, N(m) to N(f)
41KB-3 Precision Fixed Attenuator, K(m) to K(f), 3 dB, DC to 26.5 GHz, 50 Ω
41KB-6 Precision Fixed Attenuator, K(m) to K(f), 6 dB, DC to 26.5 GHz, 50 Ω
41KB-10 Precision Fixed Attenuator, K(m) to K(f), 10 dB, DC to 26.5 GHz, 50 Ω
41KB-20 Precision Fixed Attenuator, K(m) to K(f), 20 dB, DC to 26.5 GHz, 50 Ω
41KC-3 Precision Fixed Attenuator, K(m) to K(f), 3 dB, DC to 40 GHz, 50 Ω
41KC-6 Precision Fixed Attenuator, K(m) to K(f), 6 dB, DC to 40 GHz, 50 Ω
41KC-10 Precision Fixed Attenuator, K(m) to K(f), 10 dB, DC to 40 GHz, 50 Ω
41KC-20 Precision Fixed Attenuator, K(m) to K(f), 20 dB, DC to 40 GHz, 50 Ω
2000-1777-R 0.09 MHz to 20 MHz, N(f), –160 dBi to –42 dBi, Log Periodic
2000-1778-R 20 MHz to 200 MHz, N(f), –40 dBi to –3 dBi, Log Periodic
2000-1779-R 200 MHz to 500 MHz, N(f), –13 dBi to –4 dBi, Log Periodic
2000-1659-R 698 MHz to 787 MHz, N(f), 10.1 dBi, Yagi
2000-1411-R 822 MHz to 900 MHz, N(f), 12.1 dBi, Yagi
2000-1412-R 885 MHz to 975 MHz, N(f), 12.3 dBi, Yagi
2000-1660-R 1425 MHz to 1535 MHz, N(f), 14.3 dBi, Yagi
2000-1413-R 1710 MHz to 1880 MHz, N(f), 12.3 dBi, Yagi
2000-1414-R 1850 MHz to 1990 MHz, N(f), 11.4 dBi, Yagi
2000-1416-R 1920 MHz to 2170 MHz, N(f), 14.1 dBi, Yagi
2000-1415-R 2400 MHz to 2500 MHz, N(f), 14.1 dBi, Yagi
2000-1726-R 2500 MHz to 2700 MHz, N(f), 14.1 dBi, Yagi
2000-1715-R 698 MHz to 2500 MHz, N(f), 6 dBi to 7 dBi typical, Bi-Blade
2000-1677-R 300 MHz to 3000 MHz, SMA(m), 50 ohm, 3 m cable (9.8 ft)
0 to 6 dBi gain @ 950 MHz, Log Periodic
2000-1747-R 300 MHz to 5000 MHz, N(f), 4 dBi to 7 dBi typical, Log Periodic
2000-1748-R 1000 MHz to 18000 MHz, N(f), 6 dBi to 7 dBi typical, Log Periodic
PN: 11410-00548 Rev. R MS202xC/MS203xC TDS
VNA Master MS202xC/MS203xC
Optional Accessories
(continued)
Portable Antennas
Mag Mount Broadband Antennas
Ordering Information
Part Number Description
2000-1200-R 806 MHz to 866 MHz, SMA(m), 50 Ω
2000-1473-R 870 MHz to 960 MHz, SMA(m), 50 Ω
2000-1035-R 896 MHz to 941 MHz, SMA(m), 50 Ω (1/2 wave)
2000-1030-R 1710 MHz to 1880 MHz, SMA(m), 50 Ω (1/2 wave)
2000-1474-R 1710 MHz to 1880 MHz with knuckle elbow (1/2 wave)
2000-1031-R 1850 MHz to 1990 MHz, SMA(m), 50 Ω (1/2 wave)
2000-1475-R 1920 MHz to 1980 MHz and 2110 MHz to 2170 MHz, SMA(m), 50 Ω
2000-1032-R 2400 MHz to 2500 MHz, SMA(m), 50 Ω (1/2 wave)
2000-1361-R 2400 MHz to 2500 MHz, 5000 MHz to 6000 MHz, SMA(m), 50 Ω
2000-1751-R 698 MHz to 960 MHz, 1710 MHz to 2100 MHz, 2500 MHz to
2700 MHz, SMA(m), 2 dB typical, 50 Ω
2000-1616 20 MHz to 21000 MHz, N(f), 50 Ω
2000-1487 VHF/UHF, Telescopic Whip antenna, straight or 90°, BNC(m), 50 Ω
2000-1636-R Antenna Kit (Consists of: 2000-1030-R, 2000-1031-R, 2000-1032-R,
2000-1200-R, 2000-1035-R, 2000-1361-R, and carrying pouch)
2000-1647-R Cable 1: 698 MHz to 1200 MHz, 2 dBi peak gain,
1700 MHz to 2700 MHz, 5 dBi peak gain, N(m), 50 Ω, 10 ft
Cable 2: 3000 MHz to 6000 MHz, 5 dBi peak gain, N(m), 50 Ω, 10 ft
Cable 3: GPS 26 dB gain, SMA(m), 50 Ω, 10 ft
2000-1645-R 694 MHz to 894 MHz, 3 dBi peak gain
1700 MHz to 2700 MHz, 3 dBi peak gain, N(m), 50 Ω, 10 ft
2000-1646-R 750 MHz to 1250 MHz, 3 dBi peak gain,
1650 MHz to 2000 MHz, 5 dBi peak gain,
2100 MHz to 2700 MHz, 3 dBi peak gain, N(m), 50 Ω, 10 ft
2000-1648-R 1700 MHz to 6000 MHz, 3 dBi peak gain, N(m), 50 Ω, 10 ft
MS202xC/MS203xC TDS PN: 11410-00548 Rev. R
Ordering Information
Optional Accessories
(continued)
Bandpass Filters
VNA Master MS202xC/MS203xC
Part Number Description
1030-114-R 806 MHz to 869 MHz, N(m) to SMA(f), 50 Ω
1030-109-R 824 MHz to 849 MHz, N(m) to SMA(f), 50 Ω
1030-110-R 880 MHz to 915 MHz, N(m) to SMA(f), 50 Ω
1030-111-R 1850 MHz to 1910 MHz, N(m) to SMA(f), 50 Ω
1030-112-R 2400 MHz to 2484 MHz, N(m) to SMA(f), 50 Ω
1030-105-R 890 MHz to 915 MHz, N(m) to N(f), 50 Ω
1030-106-R 1710 MHz to 1790 MHz, N(m) to N(f), 50 Ω
1030-107-R 1910 MHz to 1990 MHz, N(m) to N(f), 50 Ω
1030-149-R High Pass, 150 MHz, N(m) to N(f), 50 Ω
1030-150-R High Pass, 400 MHz, N(m) to N(f), 50 Ω
1030-151-R High Pass, 700 MHz, N(m) to N(f), 50 Ω
1030-152-R Low Pass, 200 MHz, N(m) to N(f), 50 Ω
1030-153-R Low Pass, 550 MHz, N(m) to N(f), 50 Ω
1030-155-R 2500 MHz to 2700 MHz, N(m) to N(f), 50 Ω
1030-178-R 1920 MHz to 1980 MHz, N(m) to N(f), 50 Ω
1030-179-R 777 MHz to 798 MHz, N(m) to N(f), 50 Ω
1030-180-R 2500 MHz to 2570 MHz, N(m) to N(f), 50 Ω
2000-1684-R 791 MHz to 821 MHz, N(m) to N(f), 50 Ω
2000-1734-R Bandpass Filter, 699 MHz to 715 MHz, N(m) and N(f), 50 Ω
2000-1735-R Bandpass Filter, 776 MHz to 788 MHz, N(m) and N(f), 50 Ω
2000-1736-R Bandpass Filter, 815 MHz to 850 MHz, N(m) and N(f), 50 Ω
2000-1737-R Bandpass Filter, 1711 MHz to 1756 MHz, N(m) and N(f), 50 Ω
2000-1738-R Bandpass Filter, 1850 MHz to 1910 MHz, N(m) and N(f), 50 Ω
2000-1739-R Bandpass Filter, 880 MHz to 915 MHz, N(m) and N(f), 50 Ω
2000-1740-R Bandpass Filter, 1710 MHz to 1785 MHz, N(m) and N(f), 50 Ω
2000-1741-R Bandpass Filter, 1920 MHz to 1980 MHz, N(m) and N(f), 50 Ω
2000-1742-R Bandpass Filter, 832 MHz to 862 MHz, N(m) and N(f), 50 Ω
2000-1743-R Bandpass Filter, 2500 MHz to 2570 MHz, N(m) and N(f), 50 Ω
2000-1799-R Bandpass Filter, 2305 MHz to 2320 MHz, N(m) and N(f), 50 Ω
PN: 11410-00548 Rev. R MS202xC/MS203xC TDS
VNA Master MS202xC/MS203xC Ordering Information
Optional Accessories
(continued)
Related Literature, Application Notes, Manuals
Part Number Description
10580-00244 Spectrum Analyzer Measurement Guide
10580-00240 Power Meter Measurement Guide
10580-00289 VNA Measurement Guide
10580-00305 VNA Master User Guide
10580-00306 VNA Master Programming Manual
10580-00307 VNA Master Maintenance Manual
11410-00206 Time Domain for Vector Network Analyzers
11410-00214 Reflectometer Measurements – Revisited
11410-00270 What is Your Measurement Accuracy?
11410-00373 Distance-to-Fault
11410-00387 Primer on Vector Network Analysis
11410-00414 High Accuracy Power Meter, PSN50
11410-00424 USB Power Sensor MA24106A
11410-00472 Measuring Interference
11410-00476 Essentials of Vector Network Analysis
11410-00504 Microwave USB Power Sensor MA241x8A
11410-00531 Practical Tips on Making “Vector Voltmeter (VVM)” Phase
Measurements using VNA Master (Option 15)
11410-00545 VNA Master + Spectrum Analyzer Brochure
11410-00549 VNA Master + Spectrum Analyzer Technical Data Sheet
11410-00565 Troubleshoot Wire Cable Assemblies with Frequency-Domain
Reflectometry
11410-00700 Evaluation of RF Network Testing
MS202xC/MS203xC TDS PN: 11410-00548 Rev. R
Notes VNA Master MS202xC/MS203xC
PN: 11410-00548 Rev. R MS202xC/MS203xC TDS
VNA Master MS202xC/MS203xC Notes
MS202xC/MS203xC TDS PN: 11410-00548 Rev. R
The Master Users Group is an organization dedicated to providing training, technical support, networking opportunities and links to Master product development teams. As a member you will receive the Insite Quarterly Newsletter with user stories, measurement tips, new product news and more.
Visit us to register today:
www.anritsu.com/mug
Training at Anritsu
Anritsu has designed courses to help you stay up to date with technologies important to your job. For available training courses visit:
www.anritsu.com/training
• United States
Anritsu Company
1155 East Collins Blvd, Suite 100
Richardson, TX 75081, U.S.A.
Toll Free: 1-800-267-4878
Phone: +1-972-644-1777
Fax: +1-972-671-1877
• Canada
Anritsu Electronics Ltd.
700 Silver Seven Road, Suite 120
Kanata, Ontario K2V 1C3, Canada
Phone: +1-613-591-2003
Fax: +1-613-591-1006
• Brazil
Anritsu Electrônica Ltda.
Praça Amadeu Amaral, 27 - 1 Andar
01327-010 Bela Vista, São Paulo, Brazil
Phone: +55-11-3283-2511
Fax: +55-11-3288-6940
• Mexico
Anritsu Company, S.A. de C.V.
Av. Ejército Nacional No. 579 Piso 9, Col. Granada
11520 México, D.F., México
Phone: +52-55-1101-2370
Fax: +52-55-5254-3147
• United Kingdom
Anritsu EMEA Ltd.
200 Capability Green
Luton, Bedfordshire LU1 3LU
United Kingdom
Phone: +44-1582-433280
Fax: +44-1582-731303
• France
Anritsu S.A.
12 Avenue du Québec
Bâtiment Iris 1-Silic 612
91140 Villebon-sur-Yvette, France
Phone: +33-1-60-92-15-50
Fax: +33-1-64-46-10-65
• Germany
Anritsu GmbH
Nemetschek Haus, Konrad-Zuse-Platz 1
81829 München, Germany
Phone: +49-89-442308-0
Fax: +49-89-442308-55
• Italy
Anritsu S.r.l.
Via Elio Vittorini 129
00144 Roma, Italy
Phone: +39-06-509-9711
Fax: +39-06-502-2425
• Sweden
Anritsu AB
Kistagången 20B
164 40 KISTA, Sweden
Phone: +46-8-534-707-00
Fax: +46-8-534-707-30
• Finland
Anritsu AB
Teknobulevardi 3-5
FI-01530 Vantaa, Finland
Phone: +358-20-741-8100
Fax: +358-20-741-8111
• Denmark
Anritsu A/S
Kay Fiskers Plads 9
2300 Copenhagen S, Denmark
Phone: +45-7211-2200
Fax: +45-7211-2210
• Russia
Anritsu EMEA Ltd.
Representation Office in Russia
Tverskaya str. 16/2, bld. 1, 7th floor
Moscow, 125009, Russia
Phone: +7-495-363-1694
Fax: +7-495-935-8962
• Spain
Anritsu EMEA Ltd.
Representation Office in Spain
Edificio Cuzco IV, Po. de la Castellana, 141, Pta. 8
28046, Madrid, Spain
Phone: +34-915-726-761
Fax: +34-915-726-621
• United Arab Emirates
Anritsu EMEA Ltd.
Dubai Liaison Office
P O Box 500413 - Dubai Internet City
Al Thuraya Building, Tower 1, Suite 701, 7th Floor
Dubai, United Arab Emirates
Phone: +971-4-3670352
Fax: +971-4-3688460
• India
Anritsu India Private Limited
2nd & 3rd Floor, #837/1, Binnamangla 1st Stage
Indiranagar, 100ft Road, Bangalore - 560038, India
Phone: +91-80-4058-1300
Fax: +91-80-4058-1301
• Singapore
Anritsu Pte. Ltd.
11 Chang Charn Road, #04-01, Shriro House
Singapore 159640
Phone: +65-6282-2400
Fax: +65-6282-2533
• P.R. China (Shanghai)
Anritsu (China) Co., Ltd.
27th Floor, Tower A
New Caohejing International Business Center
No. 391 Gui Ping Road Shanghai, Xu Hui Di District
Shanghai 200233, P.R. China
Phone: +86-21-6237-0898
Fax: +86-21-6237-0899
• P.R. China (Hong Kong)
Anritsu Company Ltd.
Unit 1006-7, 10/F., Greenfield Tower
Concordia Plaza
No. 1 Science Museum Road, Tsim Sha Tsui East
Kowloon, Hong Kong, P. R. China
Phone: +852-2301-4980
Fax: +852-2301-3545
• Japan
Anritsu Corporation
8-5, Tamura-cho, Atsugi-shi
Kanagawa, 243-0016 Japan
Phone: +81-46-296-1221
Fax: +81-46-296-1238
• Korea
Anritsu Corporation, Ltd.
5FL, 235 Pangyoyeok-ro, Bundang-gu
Seongnam-si
Gyeonggi-do, 463-400 Korea
Phone: +82-31-696-7750
Fax: +82-31-696-7751
• Australia
Anritsu Pty Ltd.
Unit 21/270 Ferntree Gully Road
Notting Hill, Victoria, 3168, Australia
Phone: +61-3-9558-8177
Fax: +61-3-9558-8255
• Taiwan
Anritsu Company Inc.
7F, No. 316, Sec. 1, Neihu Rd, Taipei 114, Taiwan
Phone: +886-2-8751-1816
Fax: +886-2-8751-1817
List Revision Date: 20150420
® Anritsu All trademarks are registered trademarks of their respective companies. Data subject to change without notice.
For the most recent specifications visit: www.anritsu.com
Anritsu utilizes recycled paper and environmentally conscious inks and toner.
MS202xC/MS203xC VNA Master TDS
Copyright June 2015 Anritsu Company, USA
All Rights Reserved
32 of 32
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Related manuals
advertisement
Table of contents
- 2 Vector Network Analyzer Performance and Functional Highlights (All Models)
- 2 Spectrum Analyzer Performance and Functional Highlights (MS203XC Models Only)
- 3 Definitions
- 4 VNA Performance Specifications
- 5 VNA Functional Specifications
- 6 Corrected System Performance and Uncertainties — High Port Power
- 10 Distance Domain Specifications
- 10 Time Domain (Option 2) Specifications
- 10 Option Comparison Table (Distance Domain and Time Domain)
- 10 Secure Data Operation (Option 7)
- 11 Bias Tee (Option 10)
- 11 Balanced/Differential S-Parameters, 1-Port (Option 77)
- 11 Vector Voltmeter (Option 15)
- 12 Spectrum Analyzer Performance Specifications (MS203xC only)
- 14 High Accuracy Power Meter (Option 19)
- 14 Interference Analyzer (Option 25)
- 14 Channel Scanner (Option 27)
- 15 Coverage Mapping (Option 431)
- 15 GPS Receiver (Option 31)
- 16 AM/FM/PM Signal Analyzer (Option 509, MS203xC only)
- 17 General Specifications
- 19 Line Sweep Tools
- 19 Master Software Tools
- 21 Ordering Information
- 21 Standard Accessories
- 22 Optional Accessories