Untitled

Untitled
Thank you for your purchase of this product. Before operating the product,
please read this instruction manual carefully to ensure proper use of the
product. Please store this instruction manual in a safe place for future
reference.
This symbol indicates that there is a possibility of injury or damage to equipment.
(1) Use only 24V AC power supply marked class 2 or +12V DC regulated power
supply marked class 2.
(2) To prevent fire or electrical shock, UL listed class 2 wiring should be used for the
12V DC or 24V AC input terminal.
(3) Be sure to connect each lead to the appropriate terminal. Wrong connection may
cause malfunction and/or damage to the video camera.
(4) Do not attempt to aim the camera at the sun or other extremely bright objects that
cause smear to appear irrespective of whether the camera is operating or not. This
can damage the CCD (Charge Coupled Device).
(5) Do not place the camera in the following locations.
1 Locations subject to extremely high or low temperatures.
(Operating temperature range: -10°C to +50°C {14°F to 122°F})
(Storage temperature range: -20°C to +60°C {-4°F to 140°F})
2 Locations subject to high levels of humidity and dust.
(Operating humidity range: max 85% {No condensation})
(Storage humidity range: max 95% {No condensation})
3 Locations where there are large amounts of water vapor and steam.
(6) Ensure the location selected is sufficiently strong enough to support the weight of
the camera and is free from vibration.
(7) When this camera is installed near equipment that emits a strong electromagnetic
field, some irregularity such as noise on the monitor screen may happen.
(8) Be sure to use screws suitable for the type of material to which the camera is
being mounted.
(9) Do not allow the camera to be subjected to strong impacts or shocks. The camera
could be damaged by improper handling or storage.
(10) Never attempt to disassemble or modify the camera.
(11) If an abnormality should occur, immediately turn off the power and consult your
dealer.
CONTENTS
PRODUCT FEATURES ............................................................................ EG-2
SAFETY PRECAUTIONS ......................................................................... EG-2
PARTS DESCRIPTION ............................................................................ EG-3
INSTALLATION AND ADJUSTMENT ...................................................... EG-4
SPECIFICATIONS .................................................................................... EG-8
PRODUCT FEATURES
High resolution surveillance camera with a built-in 1/3-type CCD.
Integrated varifocal lens allows for versatile application and easy installation.
Accept either 12V DC or 24V AC power input. (Automatic switching)
Manual pan/tilt/rotation mechanism.
Day/Night function
D-DN (Digital Day/Night) function model: ZC-D7312PHA
The digital processing function provides a high sensitivity black and white
picture in low light conditions (e.g. nighttime) by automatically switching the
camera to black and white mode. The camera is automatically switched to
color mode in brighter light conditions (e.g. daytime).
M-DN (Mechanical Day/Night) function model: ZC-DN7312PHA
The IR cut filter automatic switching function provides a high sensitivity black
and white picture in low light conditions (e.g. nighttime) by automatically
switching the camera to black and white mode. The camera is automatically
switched to color mode in brighter light conditions (e.g. daytime).
The CE Marking is a Directive Conformity mark of the European Union (EU).
SAFETY PRECAUTIONS
Disposal of your old appliance
1. When this crossed-out wheeled bin symbol is attached to a product it means the product is
covered by the European Directive 2002/96/EC.
2. All electrical and electronic products should be disposed of separately from the municipal
waste stream via designated collection facilities appointed by the government or the local
authorities.
3. The correct disposal of your old appliance will help prevent potential negative consequences
for the environment and human health.
4. For more detailed information about disposal of your old appliance, please contact your city
office, waste disposal service or the shop where you purchased the product.
The installation should be made by a qualified service person and should conform to all local
codes.
This symbol indicates that there is a possibility of death or damage to operator or others.
To prevent fire or electric shock, do not expose this product to rain or moisture.
EG-2
Camera body interior
PARTS DESCRIPTION
Mode setting switch
Exterior
Camera mounting
hole
Lens
Dome base
N
Line phase adjustment
volume
DC iris adjustment
volume
Focus adjustment lever
T
W
View angle
adjustment lever
Camera body
Lens
Service monitor
jack
Inner cover
Power input jack
Video output connector
Dome cover
Accessories
Power plug cable
EG-3
2
INSTALLATION AND ADJUSTMENT
Installation preparation
1
Remove the dome cover.
2
Remove the inner cover.
Attach the camera body.
Attach the camera body to the ceiling or
wall.
Insert a flat-bladed screwdriver into the
groove between the dome cover and the
dome base, and then twist the screwdriver.
You can have the cables run on the
exterior surface of the ceiling or wall.
Pull up the inner cover gently when removing.
Please use fixing screws suitable
for the material of the ceiling or wall
when attaching the camera body.
We recommend using screws with a
4mm diameter.
Attaching to the bracket
You can use the tripod screw hole (1/4”
- 20UNC) to attach the camera body to
the bracket.
Installation to the ceiling or wall
1
Drill holes in the ceiling or a wall.
1 Mark the position where you want to install the unit on the ceiling or
wall using the template included.
Tightening the screws with
excessive force may damage the
camera.
2 Drill two holes for screws used to attach the camera body and one hole
for cables.
3 Connect the video and power cables. For cable connection, refer to
page EG-5, “Connecting the cables.”
EG-4
Connecting the cables
Connect the power and video cables.
1
Be sure to check that the cables are connected correctly before
turning the power on.
Turning on the power when the cables are connected with incorrect
polarity may damage the camera.
Connect the video cable.
Connect the video cable to the video output connector on the camera
body.
Use only power supply marked class 2.
Use the service monitor jack when adjusting the lens focus.
Connect the video
cable here.
2
Connect the power cable.
1 Connect the power cable and the power plug included.
2 Connect the power plug included to the power input jack on the camera
body.
12V DC connection
DC12V
RED
BLACK
To the power cable
24V AC connection
AC24V
CLASS 2
ONLY
To the power cable
EG-5
Setting the mode setting switch
Do not alter the position of the mode setting switch marked “FIX” from its factory default setting. If the set position is changed, the auto iris may
become inoperable.
Digital Day/Night model:
ZC-D7312PHA
$.$.
&)8
!'#(,
",#/./&&
&,/./&&
,,).4
7"!7"!47
$././&&
Mode setting switch
1
Mechanical Day/Night model:
ZC-DN7312PHA
2
White Balance (WB)
3
Synchronization (Sync)
4
Flickerless (FL)
5
Backlight compensation (BLC)
6
Auto Gain Control (AGC)
7
FIX
8
Day/Night sensitivity switching
$.7"3YNC&,",#!'#&)8
/.!7",,/./.($.
ON
OFF
ON
OFF
AWB
ATW
INT.
L.L.
ON
OFF
ON
OFF
H
L
/&&!47).4/&&/&&,$.
Factory default switch settings
DN1
DN2
Enables the automatic Day/Night switching. (Low light conditions: B/W, Normal light: color)
The digital processing provides high sensitivity pictures.
Color images only.
Enables the automatic Day/Night switching. (Low light conditions: B/W, Normal light: color)
The IR cut filter automatic switching provides high sensitivity pictures.
Color images only.
Locks the white balance setting.
Adjusts white balance according to the color temperature of light source.
Internal synchronization mode
Line lock mode (24V AC, 50Hz only)
Shutter speed to be fixed at 1/120.
Normal position
Set to this position when a strong light is in the back ground.
Normal position
Adjusts brightness by a high sensitivity gain in low lighting conditions. The sensitivity is higher than
in the “L” setting.
Adjusts brightness by a standard gain in low lighting conditions.
Do not change the switch position from the factory setting.
Standard brightness setting to activate the automatic Day/Night switching.
Brightness setting to activate the automatic Day/Night switching in lower lighting condition than in
DN1.
Setting the flickerless function to “ON” will give a darker picture than when set to “OFF” in low light conditions.
EG-6
Adjusting the line phase
Use an AC power-source synchronization phase
adjustment volume to adjust the phase of power
synchronization (The default position is where the
adjuster is fully turned to the left).
When using the line lock function, the
line frequency should be as follows:
NTSC—60Hz, PAL—50Hz
Adjusting the view angle and focus
Line phase
adjustment volume
Move the lever to adjust focus and angle of view.
60(!3%
$#)2)3
View angle
adjustment lever
DC iris adjustment
volume
Focus adjustment
lever
Adjusting the DC iris level
Adjust the DC iris level to suit the environment in which you are using the
unit. (The default position for the adjuster is in the center.)
Installation and adjustment complete
Adjusting the camera direction
1
Attach the inner cover.
2
Attach the dome cover to the
dome base.
The camera body is set in a tri-axial mounting allowing movement in the pan, tilt,
and rotational planes. Adjust the direction of the lens so it faces the subject.
Indicates the top of the camera
After aligning the inner cover as
shown in the right figure, push it until
you hear a click.
360º Pan
360º Rotation
After aligning the groove between
the dome cover and the dome base,
push the cover until you hear a click.
180º Tilt
Using the camera in a near-horizontal position will show the camera
cover on screen.
Do not rotate it more than once. The wiring cables within the camera
may be twisted and broken, damaging the camera.
EG-7
SPECIFICATIONS
Model No.
ZC-D7312PHA
D-DN (Digital Day/Night) function model
Focal length
Max. aperture ratio
Iris
Angle of view (Wide to Tele)
D
H
V
TV system
Scanning system
Image sensor
Effective elements
Scanning frequency
Video output
Horizontal resolution
Min. illuminance AGC L
50IRE
30IRE
AGC H
50IRE
30IRE
With IR illuminance
S/N ratio
Gamma characteristic
Sync. System
Electronic shutter
White balance
Power supply
Power consumption
DC 12V
AC 24V
Ambient temperature
Ambient humidity (No condensing)
External dimensions
Weight
Adjustable volume
Accessories
ZC-DN7312PHA
M-DN (Mechanical Day/Night) function model
3.3 mm - 12 mm
1 : 1.4
F1.4 - F360C (DC auto iris)
125.7° - 29.9°
89.8° - 23.9°
63.6° - 17.9°
PAL
2:1 Interlace
1/3-type Interline transfer CCD
752 (H) × 582 (V)
15.625 kHz (H) / 50.0 Hz (V)
1.0V (p-p) / 75Ω
More than 540 TVL
1.74 lx (D D/N : OFF) / 1.14 lx (D D/N : ON)
2.10 lx (M D/N : OFF) / 0.12 lx (M D/N : ON)
0.87 lx (D D/N : OFF) / 0.57 lx (D D/N : ON)
1.05 lx (M D/N : OFF) / 0.06 lx (M D/N : ON)
1.41 lx (D D/N : OFF) / 0.84 lx D D/N : ON)
1.41 lx (M D/N : OFF) / 0.08 lx (M D/N : ON)
0.71 lx (D D/N : OFF) / 0.42 lx (D D/N : ON)
0.71 lx (M D/N : OFF) / 0.04 lx (M D/N : ON)
—
0.00 lx
More than 50dB (At minimum AGC gain)
0.45
Internal synchronization (INT.) / Line Lock (L.L.) : For 50Hz regions only
1/50 sec. fixed (Flickerless: OFF), 1/120 sec. fixed (Flickerless: ON)
ATW / AWB
AC24V ± 10% 50Hz/60Hz ± 1Hz, DC12V ± 10%
4.2W
4.2W, 250mA
Operational limits: - 10°C to + 50°C / Storage limits: - 20°C to + 60°C
Operational limit: Maximum 85% RH / Storage limit: Maximum 95% RH
128 (ϕ) mm x 100 (H) mm
240g
DC iris adjustment volume, AC line lock phase adjustment volume
Power plug cable, Template, Instruction manual (this document)
* The specifications and/or appearance of the product may change without a prior notice.
142-1.0
EG-8