Installation Guide for the Model SW502 and Model SW507 Ethernet Switches NETGEAR, Inc. A Bay Networks Company 48105 Warm Springs Blvd. Fremont, CA 94539 USA June 1996 Document Number M-SW500NA-0 © 1996 by NETGEAR, Inc. All rights reserved. Trademarks NETGEAR and Bay Networks are trademarks of Bay Networks, Inc. Other brand and product names are registered trademarks or trademarks of their respective holders. Statement of Conditions In the interest of improving internal design, operational function, and/or reliability, NETGEAR reserves the right to make changes to the products described in this document without notice. NETGEAR does not assume any liability that may occur due to the use or application of the product(s) or circuit layout(s) described herein. Federal Communications Commission (FCC) Statement Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy. If it is not installed and used in accordance with the instruction manual, it may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case users will be required to take whatever measures may be necessary to correct the interference at their own expense. EN 55 022 Declaration of Conformance This is to certify that the NETGEAR Model SW502 and Model SW507 Ethernet Switches are shielded against the generation of radio interference in accordance with the application of Council Directive 89/336/EEC, Article 4a. Conformity is declared by the application of EN 55 022:1987 Class A (CISPR 22:1985/BS 6527:1988). WARNING: This is a Class A product. In a domestic environment, this product may cause radio interference, in which case, the user may be required to take appropriate measures. Bestätigung des Herstellers/Importeurs Es wird hiermit bestätigt, daß das NETGEAR Model SW502 and Model SW507 Ethernet Switches gemäß der im BMPTAmtsblVfg 243/1991 und Vfg 46/1992 aufgeführten Bestimmungen entstört ist. Das vorschriftsmäßige Betreiben einiger Geräte (z.B. Testsender) kann jedoch gewissen Beschränkungen unterliegen. Lesen Sie dazu bitte die Anmerkungen in der Betriebsanleitung. Das Bundesamt für Zulassungen in der Telekommunikation wurde davon unterrichtet, daß dieses Gerät auf den Markt gebracht wurde und es ist berechtigt, die Serie auf die Erfüllung der Vorschriften hin zu überprüfen. Certificate of the Manufacturer/Importer It is hereby certified that the NETGEAR Model SW502 and Model SW507 Ethernet Switches have been suppressed in accordance with the conditions set out in the BMPT-AmtsblVfg 243/1991 and Vfg 46/1992. The operation of some equipment (for example, test transmitters) in accordance with the regulations may, however, be subject to certain restrictions. Please refer to the notes in the operating instructions. Federal Office for Telecommunications Approvals has been notified of the placing of this equipment on the market and has been granted the right to test the series for compliance with the regulations. ii Voluntary Control Council for Interference (VCCI) Statement Voluntary Control Council for Interference (VCCI) Statement This equipment is in the 1st category (information equipment to be used in commercial and/or industrial areas) and conforms to the standards set by the Voluntary Control Council for Interference by Data Processing Equipment and Electronic Office Machines that are aimed at preventing radio interference in commercial and/or industrial areas. Consequently, when this equipment is used in a residential area or in an adjacent area thereto, radio interference may be caused to equipment such as radios and TV receivers. Customer Support For assistance with installing and configuring your NETGEAR system or with post-installation questions or problems, contact your point of purchase representative. To contact customer support or to purchase additional copies of this document and publications for other NETGEAR products, you can contact NETGEAR at the following numbers: • • Phone: − U.S./Canada: 1-800-211-2069 − Japan: 0031-1-26133 − Germany: 0130-8-23776 Fax: − U.S./Canada: 510-498-2609 World Wide Web NETGEAR maintains a World Wide Web Home Page that you can access at the universal resource locator (URL) http://NETGEAR.baynetworks.com/home. A direct connection to the Internet and a Web Browser such as Mosaic or Netscape are required. iii Contents Chapter 1 Introduction Overview of the Switch................................................................................................................... 1-1 Features .......................................................................................................................................... 1-2 Chapter 2 Physical Description Front Panel ..................................................................................................................................... 2-1 Ethernet Ports ............................................................................................................................ 2-2 RJ-45 Ports, Normal/Uplink Push Button and 100M-Port 2/Port 7 LED............................... 2-2 AUI Port .............................................................................................................................. 2-3 BNC Port ............................................................................................................................. 2-3 Half/Full Duplex Switches......................................................................................................... 2-3 Indicator Panel........................................................................................................................... 2-4 Power LED .......................................................................................................................... 2-4 Port Status LEDs.................................................................................................................. 2-4 Diagnostics Push Button............................................................................................................ 2-5 Rear Panel....................................................................................................................................... 2-6 Chapter 3 Installation Site Preparation............................................................................................................................... 3-1 Package Contents............................................................................................................................ 3-1 Installing a Switch .......................................................................................................................... 3-2 Installing the Switch on a Flat Surface....................................................................................... 3-2 Installing the Switch in a Rack .................................................................................................. 3-2 Connecting Devices to the Switch ................................................................................................... 3-4 Verifying Installation ...................................................................................................................... 3-6 Chapter 4 Troubleshooting Front Panel Indicators ..................................................................................................................... 4-1 Half/Full Duplex Switch ................................................................................................................. 4-1 System Diagnostics......................................................................................................................... 4-2 Installation................................................................................................................................. 4-2 Cabling...................................................................................................................................... 4-2 Network Adapter Cards ............................................................................................................. 4-2 Configuration ............................................................................................................................ 4-2 Switch Integrity ......................................................................................................................... 4-2 Contents v Chapter 5 Configuration Examples Ethernet Technology ....................................................................................................................... 5-1 Examples ........................................................................................................................................ 5-2 Bridging from 10BASE-T Ethernet Networks............................................................................ 5-2 Multiport Bridges with High-bandwidth Backbone .................................................................... 5-3 High-bandwidth File Server....................................................................................................... 5-5 High-speed Link between Switches ........................................................................................... 5-6 Appendix A Technical Specifications General Specifications.................................................................................................................... A-1 Appendix B Connector Pin Assignments RJ-45 Connector .............................................................................................................................B-1 AUI Connector................................................................................................................................B-2 BNC Connector ..............................................................................................................................B-3 BNC T-Connector and 50 Ω Terminator .........................................................................................B-3 Appendix C Cabling Specifications Cable Specifications........................................................................................................................C-1 Twisted-pair Cables ........................................................................................................................C-2 Coaxial 50 Ω Cable.........................................................................................................................C-3 AUI Cable.......................................................................................................................................C-3 Index vi Contents Chapter 1 Introduction Congratulations on your purchase of the NETGEAR Model SW502 2-Port 10/100 Mbps Ethernet switch or the Model SW507 7-Port 10/100 Mbps Ethernet switch. These switches are part of the NETGEAR 500 Series product family. The switches allow simultaneous transmission of multiple packets through an internal high-speed data channel and can partition a network more efficiently than bridges or routers in most environments. This guide is for individuals who have the following background and experience: • Working knowledge of basic Ethernet and network management concepts and terminology • Familiarity with the 10BASE-T and 100BASE-T specifications • Working knowledge of tools and procedures for installing and operating sensitive electronic equipment Overview of the Switch The Model SW502 and Model SW507 switches both increase bandwidth. To provide 10 Mbps transmission, the Model SW502 switch provides one RJ-45 station port and the Model SW507 switch provides up to six RJ-45 ports. Both switches have a 10/100 Mbps port that creates a high-throughput connection to a backbone or server. In addition to partitioning an overloaded network, these switches provide a link between traditional 10BASE-T and the faster 100BASE-TX networks. The switches can be configured to operate in either full-duplex or half-duplex data transfer mode to support the interconnection requirements of other high-speed devices. The switches incorporate a non-blocking cross-bar switching matrix that allows simultaneous transport of multiple packets across the switching hub. Up to seven switching paths can be established at the same time, with each path crossing two ports. This switching hub performs switching that sends a packet to the appropriate port according to the destination address scanned from the packet header. This technique reduces the latency of packet transmission to 20 µs or less. Compared to approximately 800 µs for a bridge or 1800 µs for a router, both of which must store the entire packet before it can be forwarded, the Model SW502 and Model SW507 switches deliver a major improvement in the performance of your network. As a device functioning on the media access control (MAC) layer, the Model SW502 and Model SW507 switches are protocol-independent, and are compatible with IEEE802.3, IEEE802.3u, TCP/IP, NetWare, DECnet, and XNS protocols. They can be easily configured in most environments as a standalone device to form a workgroup consisting of two to seven subnetworks or workstations, as a Introduction 1-1 Installation Guide for the Model SW502 and Model SW507 Ethernet Switches simple twisted-pair LAN, or as a multiport bridge. With its low port-to-port latency and highforwarding efficiency, the Ethernet switches can also be connected to other switching hubs. The maximum distance between end-nodes is not restricted as it was with the traditional repeaters. By dividing your network into smaller and more manageable segments, each linked to the larger network with a switch, the maximum distance for communications between end-nodes is unlimited. Features The key features of the NETGEAR Model SW502 and Model SW507 switches are: • Conforms to the ISO/IEC 8802-3 and ANSI/IEEE 802.3 10BASE-T standard. • Conforms to the IEEE 802.3u 100BASE-TX standard. • Improves network productivity by segmenting network traffic or providing private 10 Mbps access to the desktop or server, with no changes to the software or network interface. − One 10 Mbps Ethernet port on the Model SW502 switch provides Bayonet-Neil Councelman connector (BNC), attachment unit interface (AUI), or unshielded twisted-pair (UTP) interfaces. − Six 10 Mbps UTP Ethernet ports on the Model SW507 switch. • One additional UTP port running at 10 Mbps or 100 Mbps that can be configured as Normal (MDI-X) or Uplink (MDI). • Switch-selectable half/full duplex. Doubles the throughput of point-to-point connections by enabling individual ports to transmit and receive concurrently when the other end also supports full-duplex. • Adaptive forwarding modes. Automatically switches the forwarding mode from cut-through (minimizes network delay) to fragment-free cut-through, to store-and-forward (minimizes bad packets) as network gets increasingly busy. • Minimum latency of packet transmission (leading edge to leading edge) less than 20 µs. • Address learning function to build the routing information database. Routing table contains 4 K entries per port to store MAC addresses for attached network nodes. • Wire-speed filtering and forwarding. Provides “traffic cop” function by directing traffic to the appropriate route without slowing down the traffic. • Provides a 64 Kbyte buffer for each 10 Mbps port and a 160 K buffer for the 100 Mbps port. 1-2 Introduction Installation Guide for the Model SW502 and Model SW507 Ethernet Switches • Non-blocking cross-bar switching matrix allows concurrent operation of up to seven Ethernet segments on the Model SW507 switch in full-duplex mode. • Backpressure to alleviate congestion. Reduces network congestion by slowing down incoming traffic from other segments, when appropriate, by generating collision signals to those segments. • Microprocessor-based design to monitor network utilization, collisions, and link status. • A comprehensive LED indicator panel for monitoring overall switching condition and individual port status. For further functional descriptions of the switch, refer to Chapter 5, “Configuration Examples.” Introduction 1-3 Chapter 2 Physical Description This chapter describes the hardware features of the NETGEAR Model SW502 and Model SW507 switches. Front Panel For easier management and control of the switches, familiarize yourself with the ports, display indicators, diagnostics push button, and panel switches illustrated in Figure 2-1 and Figure 2-2. 1 = BNC, AUI, RJ-45 Ethernet ports, Normal/Uplink push button, and 100M-port 2 LED 2 = Half/Full duplex switch 3 = Power LED 4 = Port status LEDs 5 = Diagnostics push button Figure 2-1. Front panel of the Model SW502 switch Physical Description 2-1 Installation Guide for the Model SW502 and Model SW507 Ethernet Switches 1 = RJ-45 Ethernet ports, Normal/Uplink push button, and 100M-port 7 LED 2 = Half/Full duplex switch 3 = Power LED 4 = Port status LEDs 5 = Diagnostics push button Figure 2-2. Front panel of the Model SW507 switch Ethernet Ports The Model SW502 switch is equipped with one 10 Mbps port and one 10/100 Mbps port for end-node or daisy-chain connections. The 10 Mbps port supports three communication media, BNC, AUI, and UTP. On the Model SW507 switch, six 10 Mbps RJ-45 Ethernet ports and one 10/100 Mbps RJ-45 ports can be used for either end-node or daisy-chain connection. RJ-45 Ports, Normal/Uplink Push Button and 100M-Port 2/Port 7 LED The network access speed for the 10/100 Mbps RJ-45 port on both systems is automatically sensed and displayed on the front panel by the 100M-port 7 LED. A server or workstation can be connected to any of the station ports, but only one Fast Ethernet port is provided on the front panel. The 100M port is Port 2 on the Model SW502 switch and Port 7 on the Model SW507 switch. By connecting this Fast Ethernet port to a Fast Ethernet switch or hub, you can create a Fast Ethernet backbone of fast servers. The 10/100 Mbps port and the 10 Mbps port on the Model SW502 switch are equipped with a Normal/Uplink push button (Figure 2-3) to configure the port for direct server connection or for connecting with a switch or hub to form an Ethernet backbone. The push button must be set in the 2-2 Physical Description Using the Model SW502 and SW507 Ethernet Switches Normal position when connecting to a server or computer. For backbone connection to another switch or hub, the push button must be set in the Uplink position. Figure 2-3. Fast Ethernet port and Normal/Uplink push button on the Model SW502 and Model SW507 switches AUI Port The AUI port on the Model SW502 switch allows the 10 Mbps port to be connected to an external transceiver for network extension. Inter-repeater fiber transceivers for 10 BASE-F or FOIRL are examples of external transceivers. For AUI connector pin assignments, refer to Appendix B, “Connector Pin Assignments.” For cabling specifications, refer to Appendix C, “Cabling Specifications.” BNC Port The BNC connector, similar to the AUI and RJ-45 ports on the Model SW502 switch, provides 10 Mbps access for end-node or daisy-chain connections. For additional information about the BNC connector, the BNC T-connector, and the 50 Ω BNC terminator that are used to connect other devices through this port, refer to Appendix B, “Connector Pin Assignments,” and Chapter 3, “Installation.” For cabling specifications, refer to Appendix C, “Cabling Specifications.” Half/Full Duplex Switches The communication mode can be set to either half-duplex or full-duplex operation. One Half/Full duplex switch is assigned to each port on the Model SW502 and Model SW507 switches. Physical Description 2-3 Installation Guide for the Model SW502 and Model SW507 Ethernet Switches Full-duplex mode is supported for all ports. Full-duplex operation only applies to point-to-point access (such as when a switch is connected to a workstation, a server, or another switch). Repeaters and hubs use a common collision domain for all communications. When connecting to a repeater or hub, the associated port should be set to half-duplex operation. When network connection is through the BNC or AUI interfaces, the Model SW502 switch will operate in half-duplex mode only. Indicator Panel The indicator panels on the Model SW502 and Model SW507 switches can be used to monitor and diagnose the switches. The panel includes a Power LED and port status LEDs. Power LED The Power LED indicates if the switch is receiving power (refer to Table 2-1). Table 2-1. Power LED Label Color Activity Description Power Green Steady Light Switch is receiving power and system is running. No Light Power is disconnected. Port Status LEDs The port status LEDs display the status of the port connections and indicate the result of the diagnostics tests (refer to Table 2-2). These LEDs indicate when packets are being transmitted or received, when a valid link has been established, or when a collision is occurring. When the LEDs blink, they correspond to the amount of packets that are transmitted or received and the amount of collision at the port. Collisions occur when two or more devices connected to the switch attempt to transmit data at the same time on the network. When a collision occurs, devices pause and then transmit again after waiting a specified time. Because these times differ among devices, successive collisions become increasingly unlikely. 2-4 Physical Description Using the Model SW502 and SW507 Ethernet Switches Table 2-2. Port status LEDs Label Color Activity Function Collision Orange Blinking light Indicates collision during packet transmission on the port. Transmit Green Blinking light Indicates packet transmission on the port. Receive Green Blinking light Indicates packets are being received on the port. Link Green Steady light Indicates a valid link is established on this port. Light off No valid link is established on this port. For troubleshooting procedures, refer to Appendix D, “Troubleshooting.” Steady light Port is operating at 100 Mbps. Light off Port is operating at 10 Mbps. 100M Green Diagnostics Push Button The Diagnostics push button initiates the self-diagnostics test to determine the status of the system components of the switch. The diagnostic test will automatically start when the system is powered on. To start the diagnostic test after the switch has started operation, press the Diagnostics push button for two seconds and then release. After the self-diagnostic test starts, it will continue until all of the components of the ports are tested. On completion of the diagnostic testing process, the LEDs will continue to blink (refer to Table 2-3). This blinking indicates the corresponding port components that have failed. The blinking will continue until the failed port has been repaired. Table 2-3. Port Diagnostic Test LED Label Color Activity Diagnostic Display Mode Collision Orange Blinking light Failed port I.C. test. Transmit Green Blinking light Failed output queue RAM test. Receive Green Blinking light Failed input queue RAM test. Link Green Blinking light Failed routing table RAM test. For troubleshooting procedures, refer to Appendix D, “Troubleshooting.” Physical Description 2-5 Installation Guide for the Model SW502 and Model SW507 Ethernet Switches Rear Panel The rear panel of both switches contains a standard power receptacle and fans for cooling. The AC power receptacle provides connection to the AC power outlet. Both of the switches accept between 100 V and 240 V of AC power. Refer to Figure 2-4 for an illustration of the rear panel. 1 = Rear panel fans 2 = AC power outlet Figure 2-4. Rear panel of the Model SW502 and Model SW507 switches 2-6 Physical Description Chapter 3 Installation This chapter describes the installation procedures for the NETGEAR Model SW502 and Model SW507 switches. Site Preparation Before you begin installing the switch, prepare the installation site. Make sure the operating environment meets the physical requirements of the switch. The ambient temperature must be between 0° C and 40° C (32° F and 104° F). The maximum relative humidity must not exceed 90%. Package Contents Unpack the contents of the package and verify them against the following list: • Model SW502 switch or Model SW507 switch • This installation manual • Owner registration card • Rack Mount kit • AC power cord CAUTION: Use the appropriate power cord as required by your national electrical codes and ordinances. The package for the Model SW502 switch contains these additional items: • BNC T-connector • 50 Ω BNC terminator Call your dealer if there are any wrong, missing, or damaged parts. Keep the carton, including the original packing materials, to repack the switch if there is a need to return it for repair. To qualify for product updates and product warranty registration, fill in the Owner Registration Card and return it to NETGEAR, Inc. Installation 3-1 Installation Guide for the Model SW502 and Model SW507 Ethernet Switches Installing a Switch To install the switch, follow these steps: 1. Unpack the switch. 2. Choose a location near the devices to be connected and close to an electrical outlet. 3. Follow the instructions for installing the switch on a flat surface or in a rack. Installing the Switch on a Flat Surface To install the switch on a tabletop or any other flat surface, follow these steps: 1. Install self-adhesive rubber pads on the bottom of the switch. Peel off the protective backing from the rubber pads and apply one at each marked location on the bottom of the switch. 2. Set the switch on a tabletop or any other flat surface. For proper ventilation, make sure that the switch has at least two inches of space on each side and five inches of space on the back side. It is very important that the fans located in the rear panel are not blocked. Restricted airflow could cause overheating of the components. 3. Install any additional devices in your stack. Up to four switches can be stacked. For instructions on connecting to additional switches or other devices, refer to “Connecting to Other Devices” later in this chapter. Installing the Switch in a Rack For mounting the switch in a standard 19-inch rack, you need the following tools and materials: • Two mounting brackets supplied from the Rack Mount Kit • Eight screws supplied from the Rack Mount Kit to attach the mounting brackets to the switch • Four screws and nylon washers supplied from the Rack Mount Kit to attach the mounting brackets to the rack • #1 Philips screwdriver • #2 Philips screwdriver 3-2 Installation Installation Guide for the Model SW502 and Model SW507 Ethernet Switches To install the switch in a rack, follow these steps: 1. Attach the mounting brackets to the sides of the switch as illustrated in Figure 3-1. Hold a mounting bracket against each side of the switch and align the countersunk screw holes in the bracket with the bracket mounting holes in the switch. 2. Insert the screws provided with the mounting brackets through each bracket and into the bracket mounting holes in the switch. 3. Using a #1 Philips screwdriver, tighten the screws to secure each bracket. 4. Hold the switch with the mounting holes in the brackets aligned with the holes in the rack. Figure 3-1. Attaching mounting brackets to the Model SW502 and Model SW507 switches 5. Insert two pan-head screws with nylon washers through each bracket and into the rack. 6. Using a #2 Philips screwdriver, tighten the screws to secure the switch to the rack. 7. Install any additional devices in your stack. For proper ventilation, make sure that the switch has at least two inches of space on each side and five inches of space on the back side. It is very important that the fans located in the rear panel are not blocked. Restricted airflow could cause overheating of the components. For instructions on connecting to additional switches or other devices, refer to “Connecting Devices to the Switch.” Installation 3-3 Installation Guide for the Model SW502 and Model SW507 Ethernet Switches Connecting Devices to the Switch To connect devices to the switch, follow these steps: 1. Connect to another device through any of the RJ-45 ports on the switch and set the Normal/Uplink push button. The Normal/Uplink push button eliminates the need to use a cross-over cable when connecting similar devices. Use the following guidelines to configure ports for Normal or Uplink wiring: − Set the Normal/Uplink push button to the Normal position and use a straight-through cable if the remote end of the cable is connecting to an MDI-wired device such as a network station or a router. − Set the Normal/Uplink push button to the Uplink position and use a straight-through cable if the remote end of the cable is connecting to an MDI-X device such as a 10 Mbps or 100 Mbps hub or repeater. − The UTP ports without the Normal/Uplink push button are by default MDI-X ports. An RJ-45 straight-through cable must be used to connect the two ports, if using one of these UTP ports to connect to a workstation, a server, or another device with an MDI port. − An RJ-45 cross-over cable must be used to connect the two ports if using one of the UTP ports without the Normal/Uplink push button to connect to another MDI-X port. For further cabling guidelines, refer to Appendix C, “Cabling Specifications.” 2. Connect servers or workstations through either the BNC or AUI port. On the Model SW502 switch, servers, workstations, or other devices can be connected through the RJ-45, BNC, or AUI ports. Only one of the three 10 Mbps Ethernet interfaces can be used at a time. • 3-4 The AUI interface can be used to connect an external transceiver. Refer to Appendix C, “Cabling Specifications,” for further information. Installation Installation Guide for the Model SW502 and Model SW507 Ethernet Switches • When using the BNC interface, refer to Figure 3-2 and follow these steps: a. Insert the BNC T-connector on the port of the Model SW502 Switch. b. Connect the coaxial cable that leads from a device on the network to one of the self-locking ends of the BNC T-connector. c. Connect the coaxial cable that will go to another device to the remaining end of the selflocking BNC T-connector. If there are no more devices to be connected, terminate the connection with the 50 Ω terminator that is provided with the product. Figure 3-2 illustrates three switches connected through the BNC connector. The separation in the coaxial cable between the two top switches illustrates the incorporation of other devices. The figure illustrates that interconnection is not limited to switches. 1=BNC 50 Ω terminator 2=BNC T-connector Figure 3-2. Connecting devices through the BNC port using the BNC T-connector and 50 Installation terminator 3-5 Installation Guide for the Model SW502 and Model SW507 Ethernet Switches 3. Move the Half/Full duplex switches to the left to set each port on the switch for half-duplex operation, or move the switches to the right for full-duplex operation. The Model SW502 switch contains one 10 Mbps Ethernet port with BNC, AUI, or UTP interface, and one UTP port for either 10 Mbps or 100 Mbps connection that is detected by auto-sensing. The 10 Mbps ports on the Model SW502 switch support full duplex if the network is connected to the UTP port. If the network is connected to the AUI or BNC interface, half duplex is supported. The 10/100 Mbps port supports full-duplex or half-duplex operation. All of the ports on the Model SW507 switch support half or full-duplex that is controlled through a push button on the front panel. A hub or repeater uses a common collision domain for all communications and cannot support full duplex. When connecting any of the Ethernet or Fast Ethernet ports on the switch to a hub, set the port to half-duplex operation. When connecting to a workstation, a server, or a switch, the Half/Full Duplex setting for the port must be the same as the duplex setting on the connecting device. 4. Connect the appropriate end of the power cable to the power supply receptacle on the back panel of the switch. 5. Connect the other end of the power cable to a wall receptacle. The switch automatically selects the proper voltage in the range of 100 to 240 volts. The Power LED lights and the cooling fans start up after successfully completing the self-tests. The switch is now operational. Verifying Installation Verify network communications by ensuring that all the necessary connections have been made, that all connected resources can be accessed, and that the LED indicators on the switch are functioning properly. For additional information, refer to Chapter 4, “Troubleshooting.” 3-6 Installation Chapter 4 Troubleshooting This chapter provides information about troubleshooting the Model SW502 and Model SW507 switches. Front Panel Indicators The front panel indicators can assist you with identifying problems and monitors the Model SW502 and Model SW507 switches. For UTP connection, if the Link LED does not light up after making a connection, there may be a defective network adapter, cable, or port. Check for defects and replace the defective component. For AUI or BNC network connection on the Model SW502 switch, the Link LED will not light until there is data going through the port. If the Link LED does not light up when a device is connected to its corresponding UTP port, check that both the switch and the connected device are powered on. For devices connected to the switch using twisted-pair cable, check that the cable length does not exceed 100 m. Refer to Chapter 3, “Installation,” for additional information on twisted-pair or straight-through cable use. Use the diagnostic procedures described in Chapter 2 , “Physical Description,” to verify that all other system components are functioning properly. If any component fails the diagnostic test, contact your NETGEAR distributor for assistance. Half/Full Duplex Switch The default setting for the Half/Full duplex switches is half-duplex. If performance degradation is a problem or if file transfer is slow, make sure that the half- or full-duplex setting of the NETGEAR switch and the connected device are the same. When connecting any port on the switch to a repeater or hub, the port on the switch must be set to half-duplex transmission. Troubleshooting 4-1 Installation Guide for the Model SW502 and Model SW507 Ethernet Switches System Diagnostics Installation Verify that all system components have been properly installed. If one or more components are malfunctioning, test them in an alternate environment where all other components are functioning properly. Cabling Verify that the cabling is correct. Refer to Appendix C, “Cabling Specifications.” Be sure all cable connectors are securely positioned in the required ports. Straight-through cables should be used for all standard twisted-pair connections. Make sure all devices are connected to the network. Equipment may have been accidentally disconnected. Network Adapter Cards Make sure the network adapter cards/network interface cards installed in the workstations are in working condition. Be sure the AUI media transceiver is functioning properly and that the signal quality error test has been disabled. Configuration If problems occur after altering the network configuration, restore the original connections and determine the problem by implementing the new changes, one procedure at a time. Ensure that cable distances, repeater limits, and other physical aspects of the installation do not exceed the recommendations. Switch Integrity If required, verify the integrity of the switch by resetting the switch. Turn off the power to the switch and then turn the power to the switch back on. If the problem continues and you have completed all the preceding diagnoses, contact your NETGEAR distributor. 4-2 Troubleshooting Chapter 5 Configuration Examples This chapter provides an overview of Ethernet technology and the levels of service that are provided by incorporating the technology of the Model SW502 and Model SW507 switches into your network. Examples are given to illustrate the role of the switch in several configurations that provide those different levels of service to networks and users. Ethernet Technology When 10BASE-T was originally introduced, multiple repeaters were often used to build large networks. To increase the number of connections, repeaters were connected together because individual repeater port densities were often limited to 8 to 24 ports. As structured wiring systems were implemented, horizontal wiring from the wiring closet to the desktop was designed for a maximum distance of 100 m. Stackable repeaters eliminated the need for collision domains to extend over multiple repeater hubs. 100BASE-T Fast Ethernet technology maintains the same concepts of the 10BASE-T technology. Both use the same Carrier Sense Multiple Access with Collision Detection (CSMA/CD) and Media Access Control (MAC) protocol. Both 10BASE-T and 100BASE-T Ethernet use the same type of Ethernet frame and error detection mechanisms. They also support the same star topology using traditional media types, and are manageable by the same network management protocols. The most fundamental difference between the two technologies is that 100BASE-T operates 10 times faster than traditional 10BASE-T. 100BASE-T technology was developed to support the new paradigm and, by using switching technology, can provide for four distinct levels of service. Combining 10BASE-T, 100BASE-TX, and switching technology provides: • 10BASE-T shared bandwidth of 10 megabits per second (Mbps) for the group of active users. • 10BASE-T dedicated bandwidth of 10 Mbps for each user. • 100BASE-TX shared bandwidth that equals 100 Mbps for the group of active users. • 100BASE-TX dedicated bandwidth that equals 100 Mbps for each user. Configuration Examples 5-1 Installation Guide for the Model SW502 and Model SW507 Ethernet Switches Examples The NETGEAR Model SW502 and Model SW507 switches are designed to provide flexibility in configuring your network connections. The switch can be used as a standalone device or can be connected with standard repeaters, switching hubs, or other interconnection devices in various configurations. The configuration examples in this chapter illustrate the integration of the switch in network environments of all sizes and types. These examples include a network of a few workstations connected to a printer and a segmented network with multiple users and other networking devices. Bridging from 10BASE-T Ethernet Networks The Model SW502 switch can function as a two-port bridge connecting traditional Ethernet networks to 100 Mbps Fast Ethernet networks. Users requiring increased network bandwidth can be grouped together in the 100 Mbps Fast Ethernet network isolated from the network users who need occasional network connection to the server. Figure 5-1 illustrates the Model SW502 switch integrated with the NETGEAR Model EN516 10BASE-T hub and NETGEAR Model FE516 100BASE-T hub. 5-2 Configuration Examples Installation Guide for the Model SW502 and Model SW507 Ethernet Switches Figure 5-1. Model SW502 switch used as a two-port bridge Multiport Bridges with High-bandwidth Backbone Most networks are interconnected with two-port bridges that insert latency into normal communications. For data that must pass through several bridges to reach its destination, this latency can degrade communications. With several 10 Mbps bridging ports and the additional internally bridged 100 Mbps port, the Model SW507 switch can segment a complex network into a single efficient bridged node, increasing overall bandwidth and throughput. Segments attached to the switching hub do not have to cross the backbone. They can now reach each other at near-zero latency. For high-bandwidth applications that transfer data across the network backbone, the 100 Mbps port provides high-speed fast access. Figure 5-2 illustrates the NETGEAR Model EN516 10BASE-T hubs and the NETGEAR Model FE516 integrated with the Model SW507 switch. Configuration Examples 5-3 Installation Guide for the Model SW502 and Model SW507 Ethernet Switches Figure 5-2. Model SW507 switch used as a multiport bridge with high-bandwidth backbone NOTE: Full-duplex operation only applies to point-to-point access when attaching the switch to a workstation, server, or another switch. When connecting to a repeater hubs, use a standard cascaded connection set for half-duplex operation. 5-4 Configuration Examples Installation Guide for the Model SW502 and Model SW507 Ethernet Switches High-bandwidth File Server The switch increases bandwidth for workgroups and strengthens network throughput when accessing high-volume file servers. The Model SW507 switch provides parallel communication between the high-speed 100 Mbps port and each of the 10 Mbps station ports. This method of communication allows multiple conversations to occur concurrently. This method also expands overall throughput and allows key servers or other heavily used devices to be available to more users. Figure 5-3 illustrates the NETGEAR Model EN516 10BASE-T hubs integrated with the Model SW507 switch. Figure 5-3. Model SW507 switch used to link high-bandwidth file servers Configuration Examples 5-5 Installation Guide for the Model SW502 and Model SW507 Ethernet Switches High-speed Link between Switches The most common LAN implementations use a combination of standard repeater hubs, bridges, and routers. The bridges and routers become obstacles, reducing overall network throughput. Switching to higher-speed LANs, such as token ring or FDDI is not a good decision for most users. In addition to being expensive, you must replace all existing Ethernet cables and adapter cards, restructure your network, and implement more expensive administration procedures. By using switches to connect LAN segments, you retain a cohesive LAN structure in which any node can communicate with any other node in the network. For network applications that require routers, as when interconnecting different network types, attaching switches directly to a router can improve overall Ethernet performance. Figure 5-4 illustrates the NETGEAR Model EN516 10BASE-T hubs integrated with two Model SW507 switches. Figure 5-4. High-speed link between switches 5-6 Configuration Examples Appendix A Technical Specifications This appendix provides technical specifications for the NETGEAR Model SW502 and Model SW507 switches. General Specifications Network Protocol and Standards Compatibility ISO/IEC 802-3 (ANSI/IEEE 802.3I) 10BASE-T, 10BASE2, 10BASE5 IEEE 802.3u 100BASE-TX Data Rate 10 Mbps differential Manchester encoded, IEEE 802.3 100 Mbps with 4B5B encoding and MLT-3 physical interface for 100BASE-TX Interface Options AUI connector for transceiver interface RJ-45 connector for 10BASE-T Ethernet interface BNC connector for 10BASE2 coax interface Electrical Specifications Power consumption: Technical Specifications 22 W (Model SW502 switch) 33 W (Model SW507 switch) A-1 Installation Guide for the Model SW502 and Model SW507 Ethernet Switches Physical Specifications Dimensions: (W) 13 by (H) 1.7 by (D) 8 in (W) 33.0 by (H) 4.3 by (D) 20.3 cm Weight: 4.84 lb (2.2 kg) Model SW502 switch 5.02 lb (2.3 kg) Model SW507 switch Environmental Specifications Operating temperature: 0° to 40° C Storage temperature: –32° to 104° C Operating humidity: 90% maximum relative humidity, noncondensing Storage humidity: 95% maximum relative humidity, noncondensing Operating altitude: 10,000 ft (3,000 m) maximum Storage altitude: 10,000 ft (3,000 m) maximum Electromagnetic Emissions Meets requirements of: CE mark, commercial FCC Part 15, Subpart B, Class A EN 55 022 (CISPR 22), Class A VCCI Class 1 Electromagnetic Susceptibility CE mark, commercial Electrostatic discharge (ESD): IEC 801-2, Level 2/3 Radiated electromagnetic field: IEC 801-3, Level 2 Electrical fast transient/burst: IEC 801-4, Level 2 Electrical surge: IEC 801-5, Level 1/2 A-2 Technical Specifications Installation Guide for the Model SW502 and Model SW507 Ethernet Switches Safety Agency Approvals CE mark, commercial UL listed (UL 1950) CSA certified (CSA 22.2 #950) TUV licensed (EN 60 950) Performance Specifications Frame filter rate: 14,800 frames/second, maximum on 10 Mbps port 148,000 frames/second maximum on 100 Mbps port Frame forward rate: 14,800 frames/second, maximum on 10 Mbps port 148,000 frames/second maximum on 100 Mbps port Network latency: Less than 20 microseconds in cut-through mode Less than 70 microseconds for 64-byte frames in store-and-forward mode Address database size: 4 K media access control (MAC) addresses per port Addressing: 48-bit MAC address Queue buffer: 64 Kbytes/port for 10 Mbps ports 160 Kbytes/port for 10/100 Mbps ports Frame length: Technical Specifications 64-1518 bytes A-3 Appendix B Connector Pin Assignments This appendix provides information on the RJ-45 connectors that are used for the Model SW502 and Model SW507 switches and on the AUI and BNC connectors that are used for the Model SW502 switch. RJ-45 Connector The RJ-45 connector is used to connect stations, hubs, and switches through unshielded twisted-pair cable and supports 10/100 Mbps data transmission. The RJ-45 connector accepts four pair Category 5 UTP or screened 100 Ω twisted-pair cable. Figure B-1. RJ-45 connector Table B-1. RJ-45 connector pin assignments Pin Normal assignment station ports 1-7 Uplink assignment cascade Port 7 1 Input Receive Data + Output Transmit Data + 2 Input Receive Data – Output Transmit Data – 3 Output Transmit Data + Input Receive Data + 6 Output Transmit Data – Input Receive Data – 4,5,7,8 Not Used Not Used Connector Pin Assignments B-1 Installation Guide for the Model SW502 and Model SW507 Ethernet Switches AUI Connector The AUI connector for the Model SW502 switch supports 10 Mbps data transmission and connects the switch through an external transceiver to other devices. An inter-repeater fiber link for 10BASE-F or FOIRL are examples for such applications. Figure B-2. AUI connector pin assignment Table B-2. AUI connector pin assignments Pin Signal 1, 4, 11, 14, 15 Ground 2 CI-A 3 DO-A 5 DI-A 6 +12V DC return 7, 8 Not used 9 CI-B 10 DO-B 12 DI-B 13 +12V DC B-2 Connector Pin Assignments Installation Guide for the Model SW502 and Model SW507 Ethernet Switches BNC Connector The BNC connector for the Model SW502 switch supports 10 Mbps data transmission and connects the switch to other devices. 1 = center conductor 2 = ground shield Figure B-3. BNC connector on the Model SW502 switch BNC T-Connector and 50 Ω Terminator The BNC port on the Model SW502 switch, together with the BNC T-connector and the 50 Ω terminator are used for connection to a thin coaxial segment. A thin coaxial Ethernet segment supports 10 Mbps data transmission. For information on connecting through the BNC port, refer to Chapter 3, “Installation,” and Appendix C, “Cabling Specifications.” Figure B-4. BNC connector and terminator Connector Pin Assignments B-3 Appendix C Cabling Specifications This appendix provides specifications for cables used with the Model SW502 and Model 507 switches. Cable Specifications Category 5 twisted-pair cable must be used for 100 Mbps connections. For 10 Mbps connections, Category 3, 4, or 5 cables can be used; however, NETGEAR highly recommends Category 5. Category 5 cable will avoid unnecessary expenses or confusion if you upgrade to Fast Ethernet. Table C-1. Electrical requirements of Category 3, 4, and 5 cables Specification Category 3 Category 4 Category 5 Number of pairs Four Four Four Impedance 100 Ω ± 15% 100 Ω ± 15% 100 Ω ± 15% Mutual capacitance at 1 KHz 6.6 nF per 100 m 5.6 nF per 100 m 5.6 nF per 100 m Maximum attenuation (dB per 100 m, at 20° C) at 4 MHz: 5.6 at 4 MHz: 4.3 at 16 MHz: 8.2 at 10 MHz: 9.8 at 10 MHz: 7.2 at 31 MHz: 11.7 at 16 MHz: 13.1 at 16 MHz: 8.9 at 100 MHz: 22 at 4 MHz: 32 at 4 MHz: 47 at 16 MHz: 44 at 10 MHz: 26 at 10 MHz: 41 at 31 MHz: 39 at 16 MHz: 23 at 16 MHz: 38 at 100 MHz: 32 NEXT loss (dB minimum) Cabling Specifications C-1 Installation Guide for the Model SW502 and Model SW507 Ethernet Switches Twisted-pair Cables For two devices to communicate, the transmitter of each device must be connected to the receiver of the other device. The cross-over function is usually implemented internally as part of the circuitry in the device. Some repeaters and switch ports are media-dependent interfaces with cross-over ports, referred to as MDI-X or Normal ports. Computers and workstation adapter cards are usually mediadependent interface ports, referred to as MDI or Uplink ports. Refer to the installation instructions in Chapter 3, “Installation,” for appropriate cable use and connection. Figure C-1. Straight-through twisted-pair cable Figure C-2. Cross-over twisted-pair cable C-2 Cabling Specifications Installation Guide for the Model SW502 and Model SW507 Ethernet Switches Coaxial 50 Ω Cable The 50 Ω coaxial cable, together with the BNC T-connector and the 50 Ω terminator, allow a user to construct a 10BASE-2 network. Table C-2. Specifications of 10BASE2 (ThinNet) RG 58 A/U or RG 58 C/U coaxial cable Characteristic impedance Attenuation (185m cable) Transfer impedance DC loop resistance 50 +/- 2 Ω <8.5 db @ 10 MHz 20 mΩ @ 1 MHz 50 mΩ /meter <6.0 db @ 5 MHz 100 mΩ @ 10 MHz 500 mΩ @ 100 MHz The Ethernet specifications limit segments to 30 stations and specify a minimum of 0.5 m between any two stations. For optimal configuration control and network management, it is recommended that segments be limited to five attached stations. Ethernet specifications limit segments to 600 ft (185 m) in length. For optimal configuration control and network management, it is recommended that segments be limited to 100 ft (30 m). AUI Cable The AUI cable connects the AUI port on the Model SW502 switch to a transceiver. The Ethernet specifications limit the cable length to 164 ft (50 m). Cabling Specifications C-3 Installation Guide for the Model SW502 and Model SW507 Ethernet Switches Table C-3. Specifications of AUI cable Electrical characteristic AUI cable specifications Nominal dc resistance <1.75 Ω per conductor Pair-to-pair balanced crosstalk Minimum 40 dB attenuation from 5 MHz to 10 MHz Differential characteristic impedance 78 +/- 5 Ω at 10 MHz <3 Ω difference between pairs Transfer impedance <10 mΩ @ 500 KHz <3 mΩ @ 2 MHz <3 mΩ @ 10 MHz <30 mΩ @ 100 MHz Attenuation <3 dB from 5 MHz to 10 MHz Timing jitter <1.0 ns introduced by the cable system Total signal delay <257 ns C-4 Cabling Specifications Index —A— AUI connecting through, 3-4 connector pin assignments, B-2 port, 2-3 —B— BNC connecting through, 3-4 connector, B-3 port, 2-3 T-connector and 50-ohm terminator, B-3 T-connector, using in installation, 3-5 —C— cable specifications, C-1 AUI, C-3 Category 3, C-1 Category 4, C-1 Category 5, C-1 coaxial 50, C-3 twisted-pair, C-2 cabling troubleshooting, 4-2 configuration troubleshooting, 4-2 configuration examples bridging from 10BASE-T Ethernet networks, 5-2 high-bandwidth file server, 5-5 high-speed link between switches, 5-6 multiport bridges with high bandwidth, 5-3 connector AUI, 3-4 AUI pin assignments, B-2 BNC, B-3 BNC T, using in installation, 3-5 BNC-T connector and 50-ohm terminator, B-3 RJ-45, pin assignment, B-1 contents, package, 3-1 customer support, iii —D— diagnostics 100M-port 2 LED, 2-2 100M-port 7 LED, 2-2 Diagnostics push button, 2-5 port diagnostics, table, 2-5 Power LED, 2-4 system, 4-2 —E— Ethernet technology, 5-1 —F— features, 1-1 front panel, 2-1 —H— Half/Full duplex switch, 2-3 setting, 3-6 troubleshooting, 4-1 Index-1 Installation Guide for the Model SW502 and Model SW507 Ethernet Switches —I— Indicator Panel, 2-4 installation, 3-1 connecting devices to switch, 3-4 in rack, 3-2 on flat surface, 3-2 troubleshooting, 4-2 verifying, 3-6 —L— LEDs 100M-port 2, 2-2 100M-port 7, 2-2 port diagnostic table, 2-5 port status, 2-4 Power, 2-4 —N— network adapter cards troubleshooting, 4-2 Normal/Uplink push button, 2-2 setting, 3-4 —P— panel Front, 2-1 Indicator, 2-4 Rear, 2-6 port status LED, 2-4 ports AUI, 2-3 BNC, 2-3 RJ-45, 2-2 power AC, 2-6 consumption, A-1 Power LED, 2-4 prerequisite knowledge, 1-1 Index-2 —R— rear panel, 2-6 RJ-45 connecting through, 3-4 connector pin assignment, B-1 ports, 2-2 —S— setting Half/Full duplex switch, 3-6 Normal/Uplink push button, 3-4 specifications, cable, C-1 AUI, C-3 Category 3, C-1 Category 4, C-1 Category 5, C-1 coaxial 50-ohm, C-3 twisted-pair, C-2 specifications, technical, A-1 Certificate of the Manufacturer/Importer, ii data rate, A-1 electrical, A-1 electromagnetic emissions, A-2 electromagnetic susceptibility, A-2 EN 55 022 Declaration of Conformance, ii environmental, A-2 FCC Statement, ii interface options, A-1 network protocol, A-1 performance specifications, A-3 physical, A-2 safety agency approvals, A-3 standards compatibility, A-1 VCCI Statement, iii switch integrity troubleshooting, 4-2 Installation Guide for the Model SW502 and Model SW507 Ethernet Switches —T— troubleshooting, 4-1 cabling, 4-2 configuration, 4-2 front panel indicators, 4-1 Half/Full duplex switch, 4-1 installation, 4-2 network adapter cards, 4-2 switch integrity, 4-2 system diagnostics, 4-2 —U— UTP. See connector, RJ-45 and RJ-45 connector —W— World Wide Web, iii Index-3
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
advertisement