1. Features
Supports 1.5/3.0Gbps SATA I/II interface
Fully Compliant with Serial ATA International Organization:
Serial ATA Revision 2.6 Fully Compliant
Capacities
Item
Capacities
2.5inch (MLC)
256GB
Performance
Read
256GB
271 MB/s*
Write
213 MB/s*
High reliability based 48/32/28 bit ECC correct per 2K Byte data
Supports SMART (Self-Monitor Analysis and Reporting technology)
Supports Trim
UART
Supports Dynamic and Static Wear Leveling
Supports MLC NAND
MTBF > 1,000,000 Hours
Operating Voltage 5V (+/- 5%)
Power Consumption
o
Standby 0.2W
o
Read Operation 1.4W**
o
Write Operation 4.7W**
Mechanical Spec
o
Shock 1500G / 0.5ms
o
Vibration 20G / 80 – 2000Hz
Humidity: 0°C~55°C / 95% RH
o
Temperature

Operating Temperature: 0°C ~ 70°C

Storage Temperature: -40°C ~ 85°C
Fully Compliant with RoHS directive
CE and FCC tested
SSD Weight: 76g
*sequential speeds listed are based on internal testing. Actual performance may vary based on your system settings
** This was measured by Fluke 287 multimeter and the capacity was 128GB with 16pcs flash chip.
1|Page
2. Block Diagram
DDR memory
ROM
SATA Controller
& SATA PHY
SATA
Interface
RAM
ROM
32 Bits MicroController
AES/SHA/
RSA
UART
Flash
8 Channel Flash
Controller
DDR
Controller
.
.
.
Flash
PS3105 Block Diagram
3. Electrical Specifications
Signal Segment Pinout
Pin Number
Function
S1
GND
S2
A+
S3
A-
S4
GND
S5
B-
S6
B+
S7
GND
Description
2nd mate
Differential signal pair A
2nd mate
Differential signal pair B
2nd mate
2|Page
Power Segment Pinout
Pin Number
Function
P1
Not Used (3.3V)
P2
Not Used (3.3V)
P3
Not Used (3.3V Pre-Charge)
P4
GND
P5
GND
P6
GND
P7
5V Pre-Charge
P8
5V
P9
5V
P10
GND
P11
RESERVED
P12
GND
P13
Not Used (12V Pre-Charge)
P14
Not Used (12V)
P15
Not Used (12V)
Supply Voltage
Power Consumption
Parameter
Rating
OP. voltage
5V +/- 5%
Max. Ripple
100mV , 0~30MHz
*1
: This data are measured by Fluke 287 multimeter and the capacity is 128GB with 16 flashes.
Parameter
Value
Standby
0.2W
Read Operating
4.7W*1
Write Operating
1.4W*1
3|Page
4. Command Description
ATA Command List
Description
Op Code Description
Op Code
Check power mode
E5h
Security Disable Password
F6h
Data Set management
06h
Security Erase Prepare
F3h
DCO
B1H
Security Erase Unit
F4h
Download Microcode PIO
92h
Security Freeze Lock
F5h
Download Microcode DMA
93h
Security Set Password
F1h
Execute drive diagnostic
90h
Security Unlock
F2h
Flush cache
E7h
Seek
70h
Flush cache Ext
EAh
Set features
EFh
Identify device
ECh
Set Max Address
F9h
Idle
E3h
Set Max Address Ext
37h
Idle immediate
E1h
Set multiple mode
C6h
Initialize drive parameters
91h
Sleep
E6h
Read buffer
E4h
Smart
B0h
Read DMA (w/o retry)
C9h
Standby
E2h
Read DMA (w/retry)
C8h
Standby immediate
E0h
Read DMA Ext
25h
Write buffer
E8h
Read FPDMA QUEUED
60h
Write DMA (w/o retry)
CBh
Read Log Ext
2Fh
Write DMA (w/retry)
CAh
Read multiple
C4h
Write DMA Ext
35h
Read multiple Ext
29h
Write DMA FUA Ext
3Dh
Read native max address
F8h
Write FPDMA QUEUED
61h
Read native max Ext
27h
Write Log Ext
3Fh
Read sector(s) (w/o retry)
21h
Write multiple
C5h
Read sector(s) (w/retry)
20h
Write multiple Ext
39h
Read sector(s) Ext
24h
Write multiple FUA Ext
CEh
Read Verify Ext
42h
Write sector(s) (w/o retry)
31h
Read verify sector(s) (w/o retry)
41h
Write sector(s) (w/retry)
30h
Read verify sector(s) (w/retry)
40h
Write sector(s) Ext
34h
Recalibrate
10h
Write uncorrectable
45h
4|Page
Identify Device Data
F: Fixed
Word
V: Variable
Default Value
Description
X: Both
0
F
0040h
General configuration bit-significant information
1
X
3FFFh
Obsolete – Number of logical cylinders (16383)
2
V
C837h
Specific configuration
3
X
0010h
Obsolete – Number of logical heads (16)
4-5
X
00000000h
6
X
003Fh
7-8
V
00000000h
9
X
0000h
Retired
10-19
F
Varies
Serial number (20 ASCII characters)
20-21
X
0000h
Retired
22
X
0000h
Obsolete
23-26
F
Varies
Firmware revision (8 ASCII characters)
27-46
F
Varies
Model number (xxxxxxxx)
47
F
8010h
7:0- Maximum number of sectors transferred per
interrupt on MULTIPLE commands
48
F
0000h
Reserved
49
F
2F00h
Capabilities
50
F
4000h
Capabilities
51-52
X
000000000h
53
F
0007h
Words 88 and 70:64 valid
54
X
3FFFh
Obsolete – Number of logical cylinders (16383)
55
X
0010h
Obsolete – Number of logical heads (16)
56
X
003Fh
Obsolete – Number of logical sectors per track (63)
57-58
X
00FBFC10h
59
F
0110h
60-61
F
128GB - EE7C2B0h
64GB - 7740AB0h
Retired
Obsolete – Number of logical sectors per logical track
(63)
Reserved for assignment by the Compact Flash
Association
Obsolete
Obsolete – Current capacity in sectors –
Number of sectors transferred per interrupt on
MULTIPLE commands
Total number of user addressable sectors
32GB - 3BA2EB0h
16GB - 1DD40B0h
62
X
0000h
Obsolete
63
F
0407h
Multi-word DMA modes supported/selected
64
F
0003h
PIO modes supported
65
F
0078h
Minimum Multiword DMA transfer cycle time per word
5|Page
66
F
0078h
Manufacturer’s recommended Multiword DMA transfer
cycle time
67
F
0078h
Minimum PIO transfer cycle time without flow control
68
F
0078h
Minimum PIO transfer cycle time with IORDY flow
control
69
F
0100h
Additional Supported (support download microcode
DMA)
70
F
0000h
Reserved
71-74
F
0000000000000000h
75
F
001Fh
Queue depth
76
F
0706h
Serial SATA capabilities
77
F
0000h
Reserved for future Serial ATA definition
78
F
0044h
Serial ATA features supported
79
V
0040H
Serial ATA features enabled
80
F
01F8h
Major Version Number
81
F
0000h
Minor Version Number
82
F
346bh
Command set supported
83
F
70d9h
Command set supported
84
F
6023h
Command set/feature supported extension
85
V
3469h
Command set/feature enabled
86
V
bc01h
Command set/feature enabled
87
V
6023h
Command set/feature default
88
V
003Fh
Ultra DMA Modes
89
F
001Eh
Time required for security erase unit completion
90
F
001Eh
Time required for Enhanced security erase completion
91
V
0000h
Current advanced power management value
92
V
FFFEh
Master Password Revision Code
93
F
0000h
Hardware reset result. The contents of the bits (12:0) of
this word shall change only during the execution of s
hardware reset.
94
V
0000h
Vendor’s recommended and actual acoustic
management value
95
F
0000h
Stream Minimum Request Size
96
V
0000h
Streaming Transfer Time – DMA
97
V
0000h
Streaming Access Latency – DMA and PIO
98-99
F
0000h
Streaming Performance Granularity
100-103
V
256GB - 1DCF32B0h
128GB - EE7C2B0h
Reserved for the IDENTIFY PACKET DEVICE command
Maximum user LBA for 48 bit Address feature set
64GB - 7740AB0h
32GB - 3BA2EB0h
16GB - 1DD40B0h
6|Page
104
V
0000h
Streaming Transfer Time – PIO
105
F
0000h
Maximum number of 512-byte blocks per DATA SET
MANAGEMENT command
106
F
4000h
Physical sector size / Logical sector size
107
F
0000h
Inter-seek delay for ISO-7779 acoustic testing in
microseconds
108-111
F
0000000000000000h
Unique ID
112-115
F
0000000000000000h
Reserved
116
V
0000h
Reserved
117-118
F
00000000h
119
F
4015h
Supported settings
120
F
4015h
Command set/Feature Enabled/Supported
121-126
F
0h
Reserved
127
F
0h
Removable Media Status Notification feature set support
128
V
0021h
Security status
129-159
X
0h
Vendor specific
160
F
0h
Compact Flash Association (CFA) power mode 1
161-167
X
0h
Reserved for assignment by the CFA
168
F
3h 2.5 inch
Words per logical Sector
Device Nominal Form Factor
4h 1.8 inch
5h Less than
1.8 inch
169
F
0001h
170-173
F
0h
Additional Product Identifier
0h
Reserve
174-175
DATA SET MANAGEMENT command is supported
176-205
V
0h
Current media serial number
206
F
0h
SCT Command Transport(
207-208
F
0h
Reserved
209
F
4000h
Alignment of logical blocks within a physical block
210-211
V
0000h
Write-Read-Verify Sector Count Mode 3 (not support)
212-213
F
0000h
Write-Read-Verify Sector Count Mode 2 (not support)
0000h
NV Cache relate (not support)
Non-rotating media device
214-216
217
F
0001h
218
F
0h
Reserved
219
F
0h
NV Cache relate (not support)
220
V
0h
Write read verify feature set current mode
0h
Reserved
221
222
F
101Fh
Transport major version number
223
F
0h
Transport minor version number
7|Page
224-229
0h
reserved
230-233
0h
Extend number of user addressable sectors
234
0001h
Minimum number of 512-byte data blocks per
DOWNLOAD MICROCODE command for mode 03h
235
00FFh
Maximum number of 512-byte data blocks per
DOWNLOAD MICROCODE command for mode 03h
236-254
F
0h
255
X
XXA5h
Reserved
Integrity word (Checksum and Signature)
XX is variable
8|Page
5. Physical Dimension
Dimension: 100.1mm(L) x 69.9mm(W) x 9.3mm(H)
Bottom View
Side View
Top View
9|Page