Model #: SMART2200RMXL2U
Tripp Lite
1111 West 35th Street
Chicago, IL 60609 USA
Telephone: +(773) 869 1234
E-mail: saleshelp@tripplite.com
Model #: SMART2200RMXL2U
SmartPro 2.2kVA Line Interactive Sine Wave UPS, Extended-run & SNMPWEBCARD options, 2U Rack/Tower,
USB, Serial, EPO, 100/110/120V
Highlights
2.2kVA / 2200VA line interactive 2U rack / tower UPS
100/110/120V output, Corrects brownouts and overvoltages from 83V to 145V
USB, RS232, EPO and slot for optional SNMP/WEB card, Sine wave output
Front panel status LEDs with load level and battery capacity display
Expandable runtime, 97% line-mode efficiency, 3 switched output load banks
NEMA 5-20P input, 4 5-15/20R & 4 5-15R outlets
Description
2200VA line interactive UPS system for server, network and telecommunications equipment. 2U rackmount or tower form factor with an installed
depth of only 19 inches. Expandable battery runtime with optional BP48V24-2U and BP48V60RT-3U external battery packs. Uninterruptible Power
Supply (UPS) switches to battery-derived AC output during power failures and extreme voltage variations. Line interactive Automatic Voltage
Regulation (AVR) offers two levels of voltage boost during brownouts and one level of voltage cut during overvoltages to maintain regulated 100,
110, 120v selectable output over an input range of 83-145V. Includes NEMA 5-20P input plug and both NEMA 5-15R and 5-15/20R output
receptacles. Network-grade AC surge and noise suppression. Network management interfaces support simultaneous communications via USB port,
DB9 serial port and SNMPWEBCARD slot. HID-compliant USB interface enables full integration with built-in power management and auto shutdown
features of Windows and Mac OS X. Supports simultaneous detailed monitoring of equipment load levels, self-test data and utility power conditions
via all 3 network interfaces. Includes PowerAlert monitoring software and complete cabling. Emergency Power Off (EPO) interface. Integrated
3-bank PDU switching supports load shedding and remote-reboot of connected equipment. 3-stage metered current monitoring and battery charge
status LEDs. Utility power and voltage regulation LEDs. Audible alarm. Self-test. 4-post rackmount accessories included; 2-9USTAND tower kit and
2POSTRMKITWM two post rack & wallmount accessories available. Field-replaceable, hot-swappable internal batteries and external battery packs.
Attractive all-black color scheme.
Package Includes
SMART2200RMXL2U UPS system
PowerAlert software CD-ROM
USB, serial and EPO cabling
Owner's manual
Features
SmartPro line interactive UPS system is ideal for voice, data, medical and industrial networking applications
Line interactive Automatic Voltage Regulation (AVR) offers two levels of voltage boost during brownouts and one level of voltage cut during
overvoltages
Maintains continuous operation through blackouts, voltage fluctuations and surges
Corrects line voltage conditions as low as 83V and as high as 145 back to selectable 100/110/120V nominal values
Standard internal battery set offers 16 minutes at half load (800w) and 6 minutes at full load (1600w)
Optional BP48V24-2U and BP48V60RT3U external rack/tower battery packs enable extended runtime operation
Some external battery configurations require the use of Tripp Lite's External Battery Configuration Software (see manual)
Compact rackmount form factor installs using only 2 rack spaces (2U) with a maximum installed depth of only 19 inches
Ships with all mounting accessories for 4 post rackmount installation
Optional 2POSTRMKITWM enables 2 post rackmount or wallmount installation
Optional 2-9USTAND accessory enables small-footprint upright tower placement
Network interfaces support simultaneous communications via built-in USB, DB9 serial and SNMPWEBCARD slot
HID compliant USB interface enables integration with built-in power management and auto shutdown features of Windows and Mac OS X
Included PowerAlert UPS monitoring software supports safe unattended shutdown, monitoring and control via local connected servers, with
the built-in ability to shutdown any number of additional servers over IP
UPS interface supports on-battery, low-battery, power-restored, AC-voltage, DC-voltage, output current monitoring, battery charge current,
battery capacity, AC line frequency, timed inverter shutoff, activate self-test, load bank output power control and remote reboot
Built-in Emergency Power Off (EPO) interface with cable
NEMA 5-20P input plug / NEMA 5-15R & NEMA 5-15/20R output receptacles
Integrated 3 bank switched PDU enables remote outlet management for load shedding or remote reboot of individual load banks (Each
bank controls 1 outlet per load bank)
Front panel LEDs offer current monitoring and battery charge level information
UPS ships fully assembled in full compliance with DOT regulations, no time consuming connection of internal batteries by user required
Specifications
OUTPUT
Output Volt Amp Capacity
(VA)
2200
Output kVA capacity (kVA)
2.2
Output Watt Capacity
(watts)
1600
Output kW capacity
1.6
Output power factor
0.7
Nominal Output Voltage(s)
Supported
100V; 110V; 120V
Nominal Voltage details
120V default (voltage selection via back panel dipswitches)
Frequency compatibility
50 / 60 Hz
Output voltage regulation
(line mode)
-14%, +6%
Output voltage regulation
(Battery mode)
+/- 5%
Built-in UPS output
receptacles
4 5-15R outlet(s); 4 5-15/20R outlet(s)
Built-in controllable
switched load banks
Three switchable single-outlet 5-15R load banks
Output AC waveform (AC
mode)
Sine wave
Output AC waveform
(battery mode)
Pure Sine wave
INPUT
Rated input current (at
maximum load)
13.3A (120V), 14.6A (110V), 16.0A (100V)
Nominal Input Voltage(s)
Supported
120V AC
UPS input connection type
5-20P
Input circuit breaker
20A
UPS Input cord length (ft.)
10
UPS Input cord length (m)
3
Recommended Electrical
Service
20A 120V
BATTERY
Full load runtime (minutes)
6 min. (1600w)
Half load runtime
(minutes)
16 min. (800w)
Expandable battery
runtime
Extended runtime supported via optional external battery packs
External battery pack
compatibility
BP48V24-2U (limit 1); BP48V60RT-3U (multi-pack compatible)
DC system voltage (VDC)
48
Battery recharge rate
(included batteries)
Less than 4.5 hours from 10% to 90%
Replacement battery
cartridge (internal UPS
battery replacement)
RBC94-2U
Battery Access
Front panel battery access door
Battery replacement
description
Hot-swappable, user replaceable batteries
VOLTAGE REGULATION
Voltage regulation
description
Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 79 to 147
Overvoltage correction
Voltage reduction of 12% applies when input is between 127 and 145 (120V), 116 and 133 (110V), 106 and
121 (100V)
Undervoltage correction
Voltage boost of 12% applies when input voltage is between 96 and 108 (120V), 87 and 99 (110V), 83 and 90
(100V)
Severe undervoltage
correction
Voltage boost of 24% applies when input voltage is between 83 and 95 (120V only)
LEDS ALARMS & SWITCHES
LED Indicators
5 LEDs indicate line power, battery power, overload, voltage regulation and battery low/replace status
Alarms
Audible alarm indicates power-failure, overload and low-battery conditions
Alarm cancel operation
Power-fail alarm can be silenced using alarm-cancel switch; once silenced, alarm will re-sound to indicate
low-battery status
Switches
2 Switches control off/on power status and alarm-cancel/self-test operation; rear panel protected switches
support nominal voltage selection
SURGE / NOISE SUPPRESSION
UPS AC suppression
joule rating
570
UPS AC suppression
response time
Instantaneous
EMI / RFI AC noise
suppression
Yes
PHYSICAL
Included mounting
accessory description
Adjustable mounting rail kit included
Installation form factors
supported with optional
accessories
2 post rackmount (2POSTRMKITWM); Wallmount (2POSTRMKITWM); Tower (2-9USTAND)
Primary form factor
Rackmount
UPS / Power Module
dimensions in primary
form factor (height x width
x depth / inches)
3.5 x 17.5 x 19
UPS / Power Module
dimensions in primary
form factor (height x width
x depth / cm)
8.9 x 44.4 x 48.3
Installed whole system
total rack space height
(rack spaces)
2U
Secondary form factor
Tower (requires 2-9USTAND)
UPS / Power Module
weight (lbs)
64
UPS / Power Module
weight (kg)
29.1
UPS Shipping dimensions
(height x width x depth /
inches)
9 x 23.5 x 20
UPS Shipping dimensions
(height x width x depth /
cm)
22.9 x 59.7 x 50.8
Shipping weight (lbs)
72
Shipping weight (kg)
32.7
UPS housing material
Steel
Cooling method
Fan
ENVIRONMENTAL
Operating Temperature
Range
+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius
Storage Temperature
Range
+5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius
Relative Humidity
0 to 95%, non-condensing
AC mode BTU / hr. (full
load)
168.2
Battery mode BTU / hr.
(full load)
604.4
COMMUNICATIONS
Communications interface
USB (HID enabled); DB9 Serial; EPO (emergency power off); Slot for SNMP/Web interface
Network monitoring port
description
Supports detailed monitoring of UPS and site power conditions
PowerAlert software
Included
Communications cable
USB and DB9 cabling included
WatchDog compatibility
Supports Watchdog application, OS and hard-reboot restart options for remote applications
LINE / BATTERY TRANSFER
Transfer time
2-4 milliseconds
Low voltage transfer to
battery power (setpoint)
83 (120V), 87 (110V), 83 (100V)
High voltage transfer to
battery power (setpoint)
145 (120V), 133 (110V), 121 (100V)
SPECIAL FEATURES
Grounding lug
Back panel grounding lug
Cold Start (startup in
battery mode during a
power failure)
Cold-start operation supported
High availability UPS
features
Hot swappable batteries
Green & high efficiency
features
Greater than 95% efficiency - GREEN UPS; Individually controllable load banks
CERTIFICATIONS
UPS Certifications
Tested to UL1778 (USA); Tested to CSA (Canada); Tested to NOM (Mexico); Meets FCC Part 15 Category A
(EMI)
WARRANTY
Product Warranty Period
(Worldwide)
2-year warranty, 3 year with registration. Note: registration is required for 3-year warranty.
Connected Equipment
Insurance (U.S., Canada &
Puerto Rico)
$250,000 Ultimate Lifetime Insurance
Related Items
Optional Products
Related Model
Description
Qty.
BP48V24-2U
BP48V242U - External Battery Pack for UPS System
1
BP48V60RT-3U
External Battery Pack and Cable. 3U, Expandable, Blue 2-Point Connector
1
DCATV
Network Surge Suppressor - Essential protection for TV/VCR coaxial lines
1
DNET1
Network Surge Suppressor - Essential protection for data and communication lines
1
DTEL2
Network Surge Suppressor - Essential protection for data and communication lines
1
ENVIROSENSE
Monitors temperature, humidity and contact-closure inputs. (Requires SNMPWEBCARD
or switched PDU.)
1
PDU1220
Basic PDU / Power Distribution Unit - Safe, reliable power distribution for critical
networking equipment
1
PS7224-20
Tripp Lite Power Strip - Multiple outlets wherever you need them
1
SNMPWEBCARD
For remote monitoring and control via SNMP, Web, or Telnet.
1
U022-010
10-ft. USB2.0 A/B Gold Device Cable
(A Male to B Male)
1
WATCHDOGSW
WatchDog Service Monitoring / Reboot Software
1
WEXT5-2200-3000
5-Year Extended Warranty - For Smart Line-Interactive and Online Tower or Rack
models, 2200-3000VA or less
1
2-9USTAND
Enables Tower Placement of Rackmount UPS Systems
1
2POSTRMKITWM
Enables 2-Post Rackmount or Wallmount Installation of Select Rackmount UPS Systems
1
MODBUSCARD
For remote monitoring and control via MODBUS protocol
1
More information, including related products, owner's manuals, and additional technical specifications, can be found online at
www.tripplite.com/en/products/model.cfm?txtModelID=3264.
Copyright © 2012 Tripp Lite. All rights reserved. All trademarks are the sole property of their respective owners. Tripp Lite has a policy of continuous
improvement. Specifications are subject to change without notice. Photos may differ slightly from final products.
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising