※Introduction※
The Armored 170L dehumidifier has been introduced to serve the demands of mediumsized areas without using multiple units. Warehouses, factories, offices and other mediumscale facilities with ambient temperatures ranging from 0.5°C where occur humidity and condensation problems can been handled efficiently and automatically. The Armored 170L unit can be utilized singly or in multiple units to provide protection on any scale. Ducted applications are possible when design requirements are specified.
※ Features/Specifications ※
Super Cop,3.5L/Kwh R410A Refrigerant
Low Sound Levels <63DBA Humity can be fixed within 1%
Purification
Timing
Universal Wheel
Memory starting
Automatic humidistat control,Display Tube TEM
The temperature control defrosting , more thorough, and more quick
Note: This dehumidification capacity is at room temperature 30 ℃, relative humidity of
80% income test conditions
Identification:
For future reference, write down the model, serial number, and date of purchase so you can identify your unit when seeking assistance. NOTE: data label on back of unit includes serial number.
Model Number Armored 170L
Serial Number__________________________ Date of Purchase__________________________
Customer Service:
For additional questions concerning the operation of your dehumidifier,
-1-
DEHUMIDIFIERS please:
E-mail: [email protected]
Installation:
WARNING!
240 Volts AC may cause serious injury from electric shock.
1. Disconnect electrical power before servicing 2. Only plug unit into grounded electrical outlet
3. Do not use extension cord 4. Do not use plug adapter
Power Supply: 220V, 50 Hz AC Only 1 Phase
Outlet Requirement: 3-Prong, GFI
Circuit Protector: 15 Amp Time Delay Fuse or Circuit Breaker
WARNING
When using this machine , please note the following safety warnings :
2. Do not immerse the machine in water or near water .
3. Do not place the machine near a heating device or flammable dangerous place.
4. Do not put your fingers or other objects into the outlet or plug the outlet .
5. Do not sit on this machine table .
6. Follow the requirements of the tank to drain .
7. Do not use this machine in a sealed environment to avoid fire.
8. Make sure the condensate drain down the installation so that you can continue to be excluded .
9. If the power cord is damaged , please find the manufacturer or a qualified service organization .
10. prohibit people with and without self-care ability or children to use the machine without a guardian.
11. The machine must have a reliable ground lead or grounded outlet.
-2-
DEHUMIDIFIERS
※Unit Overview※
※ Front View
Front cover
Air Intake
Filter
Air Outake
Control Panel
Hand Dug
Wheel
※ Rear View
Rear cover
Drain Tube
Connection
Wheel
-3-4-
DEHUMIDIFIERS
Air Outake
Side Cover
Hand Dug
A
DEHUMIDIFIERS
※Operating instructions※
B
LCD Monitor
※Control Panel Operation
A. Power Button: “Switch”key: turn on or off for each time in the boot, the conversion between off once . Note shutdown after fan delay stopped after 1 minutes.
B. " Up" and "Down" Button:
1)Adjust the humidity figures used for the humidity set button once every 1% rise or fall .
hour.
2)Adjust the time used for digital switch time setting, up or down button once every
Note: The "up" and "down" button to set within the 3S does not operate after that set success. While holding down the Up and Down keys 2S can lock the keys , lock button to exit the same way ).
DEHUMIDIFIERS
※Lamp operation
this does not light , turned on, the lights lit , after the shutdown , the lights off . ( Note: The standby display digital display profit or humidity )
(2)Continuous running lights : In continuous mode , the lights lit , the other states , this lamp is off .
(3)Defrost indicator: When entering this light Always defrost operation , defrost termination or other states , this lamp is off .
※Preparing the Unit for Use※
A. The placement of the machine : The machine can be placed in the figure requires full play to its performance.
-5-6-
DEHUMIDIFIERS
B.This machine uses a value consistent with the nameplate power outlet must be grounded port.
C. Remove the power cord and reliably , securely plugged into a power outlet.
D. Make sure the machine 's inlet and outlet is not blocked or blocking other objects.
Ensure the inlet and outlet of the machine can effectively play the smooth performance of the machine and reduce electricity costs .
E. Before starting the outlet pipe into a drainage tank or water container.
※Use Instructions※
1 . " On / Off " Button : reaches the starting condition. Such as to reach the starting, such as the current humidity is lower than the setting humidity, then do not start, running lights shining.
b.Press this" "button again,the unit will stop running .
※ Preferably stand for 10 minutes , so that the remaining water droplets on the evaporator flows into the water tanks .
Please unplug the power cord after the machine is turned off to save standby power consumption and avoid the risk of accidents .
-7-
DEHUMIDIFIERS
2 ."Up" and "Down" Button
Used to adjust the set humidity , also used to adjust the timing shutdown and timing for the start of the set time.
• Humidity setting adjustment range : Between 35 to 90 percent , up or down button once for each 1% , when the set humidity < 35% , digital display "C0" enter the continuous dehumidification mode , the first power-on defaults "50 %." ( Note : Continuous dehumidification mode not affected by humidity )
※ Maintenance and Repair ※
WARNING!
Be sure to turn off the power before for maintenance to avoid accidents !
1. Clean the filter
Because of the air filter is easy to accumulate dust , blocking the air intake passage , thereby affecting the dehumidification effect , therefore, must be regularly cleaned.
If the machine is in larger dust places, should be cleaned once a ~ 5 days .
If the machine is used in relatively clean environment can be cleaned once a month.
Filter
-8-
DEHUMIDIFIERS
Clean the filter method :
1.Remove the filter,Filiter may be cleaned by Vacumming or By washing with warm water(no soap or Solvents),Insure
Fliter is dry prior to Restarting unit
2. Make Tank Empty and Unplug the Unit when it is not in using.
3. Do not use the machine near the stove , heaters and other heat sources or air outlet of places, so as not to affect the dehumidifying effect or danger.
4. Do not use machine in where have Water Splash potential problem,to prevent the leakage of dangerous
5. After the machine should be placed firmly before use, to prevent dumping, to avoid injury.
6. When using dehumidifiers in wooden furniture , floors and environments
in attention control humidity , excessive dry conditions may cause the wood to crack.
7. Severe turbulence , impact and tilt angles are large damage the machine : If running noise becomes larger and so on . And the inclination angle of the large residual moisture may cause the machine overflow.
8. Storage H, dehumidifier
When you are not using the product for a long time , and intended to be stored or collection, consider the following steps:
1) The residual water tank emptying.
2) The dust filter clean .
3) Placement. fresh dry environment .
DEHUMIDIFIERS
※ Troubleshooting ※
Trouble
Machine Won’t Work/
Display is Blank machinery not exceed water or dehumidify
quantity small
Trouble code:E1 cause
Display Blank. Power outage or poor connection
Room temperature whether in
5℃~ 35℃this inner?
Filtration net whether jam
Room inner humidity temperature too low
Outlet or the outlet is blocked
Humidity Sensor or communication error
Unit is sensing room temperature below 33°F.
Unit is sensing room temperature above 100°F.
Solution
Check Power Supply
Check both ends of powercord for good connection
Place unit on flat surface in vertical orientation
Clear the filter
Normal work condition
Clear obstructions
Check sensor cable is properly connected.Replace the Senser
Increase room temperature
Check Sensor
Check Sensor Cable
Decrease Room Temp
Check Sensor
Check Sensor Cable
-9-10-
DEHUMIDIFIERS
※WARRANTY※
Seller warrantys the equipment to be free from defects in workmanship and materials for a period of 12 months after shipment (60 months/5 years on compressor, evaporator and condenser). This warranty is limited, however, to the repair or replacement of defective equipment. If it is necessary to return unit for service, customer is solely responsible for proper packaging, transportation costs. Customer must initiate warranty process by contacting factory. Do not send any component or product back to factory without Return Material Authorization.
This limited warranty does not apply to any part or component that is damaged in transit or when handling, has been subject to misuse, corrosion, chemicals, acts of
God has not been installed, operated or serviced according to the Seller's instructions, or has been operated beyond the factory-rated capacity or has been altered in any way. Routine maintenance is not covered by this warranty.
Seller's liability is limited to replacement of defective parts or components and does not include any cost of labor (including, but not limited to, labor to remove and/or reinstall any defective part), refrigerant or piping. Customer may elect to have unit fixed locally in which case required replacement parts will be sent to customer at customer's expense.
ALORAIR shall not be responsible for loss of use of any product, loss of time, inconvenience, or damage to other equipment, or any other indirect or consequential damage with respect to property whether as a result of breach of warranty, neglect, or otherwise.
THE WARRANTIES AND LIABILITIES SET FORTH ARE IN LIEU OF ALL
OTHERWARRANTIES EXPRESSED OR IMPLIED, IN LAW OR IN FACT, INCLUDING
IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR PARTICULAR
PURPOSE.
ALORAIR's total liability, regardless of nature of claim shall not exceed original purchase price of the product. If a product or component is replaced while under warranty, the applicable warranty period shall not be extended beyond the original warranty time period.
The foregoing shall constitute the total liability of seller in the case of defective performanceof all or any of the equipment or services provided to Buyer. Buyer agrees to accept and hereby accepts the foregoing as the sole and exclusive remedy for any breach or alleged breach of warranty by Seller.
advertisement